PRIME MOVERS AND GOVERNINGPRIME MOVERS AND GOVERNING
SYSTEMSSYSTEMS
Copyright © P. Kundur
This material should not be used without the author's consent
1539pk
PM - 2
Prime Movers and Governing SystemsPrime Movers and Governing Systems
1. Hydraulic Turbines and Governing Systems
 hydraulic turbine transfer function
 special characteristics of hydraulic turbines
 nonlinear hydraulic turbine model
 governors for hydraulic turbines
 tuning of speed governors
2. Steam Turbines and Governing Systems
 steam turbine configurations
 steam turbine models
 steam turbine controls
3. Gas Turbines and Governing Systems
 simple-cycle configuration
 combined-cycle configuration
Outline
1539pk
PM - 3
Hydraulic Turbines and GoverningHydraulic Turbines and Governing
SystemsSystems
 The performance of a hydraulic turbine is
influenced by the characteristics of the water
column feeding the turbine:
 water inertia
 water compressibility
 pipe wall elasticity in the penstock
 The effect of water inertia is to cause changes in
turbine flow to lag behind changes in turbine
gate opening
 The effect of elasticity is to cause traveling
waves of pressure and flow in the pipe - a
phenomenon referred to as water hammer
 typically, the speed of propagation of such waves
is about 1200 meters/sec
 traveling wave model required only if penstock is
very long
1539pk
PM - 4
 The representation of the hydraulic turbine and
water column in stability studies usually
assumes that (a) the penstock is inelastic, (b) the
water is incompressible, and (c) hydraulic
resistance is negligible
 The turbine and penstock characteristics are
determined by three basic equations relating to:
 velocity of water in the penstock
 turbine mechanical power
 acceleration of water column
1. Hydraulic Turbine Transfer Function1. Hydraulic Turbine Transfer Function
Figure 9.2: Schematic of a hydroelectric plant
1539pk
PM - 5
The velocity of the water in the penstock is given
by
where
U = water velocity
G = gate position
H = hydraulic head at gate
Ku = a constant of proportionality
The turbine mechanical power is proportional to
the product of pressure and flow; hence,
The acceleration of water column due to a change
in head at the turbine, characterized by Newton's
second law of motion, may be expressed as
where
L = length of conduit
A = pipe area
ρ = mass density
ag = acceleration due to gravity
ρLA = mass of water in the conduit
ρag∆H = incremental change in pressure at
turbine gate
HGKU u=
HUKP pm =
( ) ( ) HaA
dt
Ud
LA g ∆ρ−=
∆
ρ
1539pk
PM - 6
 For small displacements (prefix ∆) about an initial
operating point (subscript "0") we can shows that
where
 Tw is referred to as the water starting time. It
represents the time required for a head H0 to
accelerate the water in the penstock from standstill to
the velocity U0. It should be noted that Tw varies with
load. Typically, Tw at full load lies between 0.5 s and
4.0 s.
 Equation 9.11 represents the "classical" transfer
function of the turbine-penstock system. It shows
how the turbine power output changes in response to
a change in gate opening for an ideal lossless turbine.
ST
2
1
1
ST1
G
P
w
wm
+
−
=
∆
∆
0g
0
w
Ha
LU
T =
(9.11)
1539pk
PM - 7
Special Characteristics of Hydraulic Turbines
 The transfer function given by Equation 9.11
represents a "non-minimum phase" system
Systems with poles or zeros in the right half of
s-plane are referred to as non-minimum phase
systems; they do not have the minimum amount of
phase shift for a given magnitude plot. Such
systems cannot be uniquely identified by a
knowledge of magnitude versus frequency plot
alone.
 The special characteristic of the transfer function
may be illustrated by considering the response to a
step change in gate position. The time response is
given by:
 Figure 9.3 shows a plot of the response of an ideal
turbine model with Tw = 4.0 s
( ) Ge31tP
t
T
2
m
w
∆








−=∆





−
1539pk
PM - 8
Figure 9.3: Change in turbine mechanical power
following a unit step increase in gate position
1539pk
PM - 9
 Immediately following a unit increase in gate
position, the mechanical power actually decreases
by 2.0 per unit. It then increases exponentially
with a time constant of Tw/2 to a steady state value
of 1.0 per unit above the initial steady state value
 The initial power surge is opposite to that of the
direction of change in gate position. This is
because, when the gate is suddenly opened, the
flow does not change immediately due to water
inertia; however, the pressure across the turbine
is reduced causing the power to reduce.
 With a response determined by Tw, the water
accelerates until the flow reaches the new steady
value which establishes the new steady power
output
1539pk
PM - 10
Governors for Hydraulic TurbinesGovernors for Hydraulic Turbines
 The speed/load control function involves feeding back
speed error to control the gate position. In order to
ensure satisfactory and stable parallel operation of
multiple units, the speed governor is provided with a
droop characteristic.
 Typically, the steady state droop is set at about 5%,
such that a speed deviation of 5% causes 100% change
in gate position or power output; this corresponds to a
gain of 20.
 For a hydro turbine, however, such a governor with a
simple steady state droop characteristic would be
unsatisfactory
Requirement for a Transient Droop
 Hydro turbines have a peculiar response due to water
inertia: a change in gate position produces an initial
turbine power change which is opposite to that
sought.
 For stable control performance, a large transient
(temporary) droop with a long resetting time is
therefore required. This is accomplished by the
provision of a rate feedback or transient gain
reduction compensation as shown in Figure 9.8
1539pk
PM - 11
 The rate feedback retards or limits the gate
movement until the water flow and power output
have time to catch up
 The result is a governor which exhibits a high
droop (low gain) for fast speed deviations, and
the normal low droop (high gain) in the steady
state
Figure 9.8: Governor with transient droop compensation
1539pk
PM - 12
Mechanical Hydraulic GovernorMechanical Hydraulic Governor
 On older units, the governing function is realized
using mechanical and hydraulic components
 Speed sensing, permanent droop feedback, and
computing functions are achieved through mechanical
components; functions involving higher power are
achieved through hydraulic components
 A dashpot is used to provide transient droop
compensation. A bypass arrangement is usually
provided to disable the dashpot if so desired.
 Water is not a very compressible fluid; if the gate is
closed too rapidly the resulting pressure could burst
the penstock
 Consequently, the gate movement is rate limited
 Often, the rate of gate movement is limited even
further in the buffer region near full closure to provide
cushioning
1539pk
PM - 13
Figure 9.9: Schematic of a mechanical-hydraulic governor
for a hydro turbine
1539pk
PM - 14
Parameters Sample data
Tp = Pilot valve and servomotor time
constant
0.05 s
Ks = Servo gain 5.0
TG = Main servo time 0.2 s
Rp = Permanent droop 0.04
RT = Temporary droop 0.4
TR = Reset time 5.0 s
Constraints
Maximum gate position limit = 1.0
Minimum gate position limit = 0
Rmax open = Maximum gate opening rate 0.16 p.u./s
Rmax close = Maximum gate closing rate 0.16 p.u./s
Rmax buff = Maximum gate closing rate in
buffered region
0.04 p.u./s
gbuff = Buffered region in p.u. of
servomotor stroke
0.08 p.u.
Figure 9.10: Model of governors for hydraulic turbines
1539pk
PM - 15
Electro-Hydraulic GovernorElectro-Hydraulic Governor
 Modern speed governors for hydraulic turbines use
electric-hydraulic systems. Functionally, their
operation is very similar to those of mechanical-
hydraulic governors
 Speed sensing, permanent droop, temporary droop,
and other measuring and computing functions are
performed electrically
 Electric components provide greater flexibility and
improved performance with regard to dead-bands and
time lags
 Dynamic characteristics of electric governors are
usually adjusted to be essentially similar to those of
mechanical-hydraulic governors
1539pk
PM - 16
Tuning of Speed Governing SystemsTuning of Speed Governing Systems
 There are two important considerations in the
selection of governor settings:
 Stable operation during system islanding conditions or
isolated operation; and
 Acceptable speed of response for loading and
unloading under normal synchronous operation
 For stable operation under islanding conditions, the
optimum choice of the temporary droop RT and reset
time TR are as follows:
 For loading and unloading during normal
interconnected system operation, the above settings
result in too slow a response. For satisfactory
loading rates, the reset time TR should be less than
1.0 s, preferably close to 0.5 s.
 The dashpot bypass arrangement can be used to
meet the above conflicting requirements
( )[ ]
M
w
wT
T
T
15.00.1T3.2R −−=
( )[ ] wwR T5.00.1T0.5T −−=
1539pk
PM - 17
2. Steam Turbines and Governing2. Steam Turbines and Governing
SystemsSystems
 A steam turbine converts stored energy of high
pressure and high temperature steam into rotating
energy
 the heat source may be a nuclear reactor or a fossil
fired boiler
 Steam turbines with a variety of configurations have
been built depending on unit size and steam
conditions
 normally consist of two or more turbine sections or
cylinders coupled in series
 A turbine with multiple sections may be
 tandem-compound: sections are all on one shaft with a
single generator, or
 cross-compound: sections are on two shafts, each with
a generator; operated as a single unit
 Fossil-fuelled units can be of tandem-compound or
cross-compound design
 may be of reheat or non-reheat type
1539pk
PM - 18
Figure 9.16: Common configurations of tandem-compound
steam turbine of fossil-fueled units
1539pk
PM - 19
Figure 9.17: Examples of cross-compound steam turbine
configurations
1539pk
PM - 20
 Nuclear units usually have tandem-compound
turbines
 moisture separator reheater (MSR) reduces moisture
content, thereby reducing moisture losses and erosion
rates
 Large steam turbines for fossil-fuelled or nuclear
units are equipped with four sets of valves
 main inlet stop valves (MSV)
 main inlet control (governor) valves (CV)
 reheater stop valves (RSV)
 reheater intercept valves (IV)
 The stop valves (MSV and RSV) are primarily
emergency trip valves.
 The CVs modulate steam flow during normal
operation.
 The CVs as well as the IVs limit overspeed.
Figure 9.18: An example of nuclear unit turbine configuration
1539pk
PM - 21
Steam Turbine ModelSteam Turbine Model
 For illustration, let us consider a fossil-fuelled single
reheat tandem-compound turbine, a type in common
use
 Figure 9.21(a) identifies the turbine elements that need
to be considered
 Figure 9.21(b) shows the block diagram representation
 The CVs modulate the steam flow for load/frequency
control
 the response of steam flow to CV opening exhibits a
time constant TCH due to charging time of the steam chest
and inlet piping
 TCH is of the order of 0.2 to 0.3 s
 The IVs are used only for rapid control of turbine
power in the event of an overspeed
 control about 70% of total power
 the steam flow in the IP and LP sections can change
only with the build-up of pressure in the reheater volume
 the reheater time constant TRH is in the range 5 to 10 s
 the steam flow in LP sections experiences a time
constant TCO associated with the crossover piping; this is
of the order of 0.5 s
1539pk
PM - 22
Parameters
TCH = time constant of main inlet volumes and steam chest
TRH = time constant of reheater
TCO = time constant of crossover piping and LP inlet
volumes
Pm = total turbine power in per unit of maximum turbine
power
Pmc = total turbine mechanical power in per unit of common
MVA base
PMAX = maximum turbine power in MW
FHP,FIP,FLP = fraction of total turbine power generated by HP, IP,
LP sections, respectively
MVAbase = common MVA base
Figure 9.21: Single reheat tandem-compound steam turbine
model
1539pk
PM - 23
Simplified Transfer Function of a SteamSimplified Transfer Function of a Steam
TurbineTurbine
A simplified transfer function of the turbine
relating perturbed values of the turbine power
and CV position may be written as follows:
It is assumed that TCO is negligible in comparison
with TRH, and that the CV characteristic is linear
( )( )
( )( )RHCH
RHHP
RHCH
HP
CH
HP
CV
m
sT1sT1
TsF1
sT1sT1
F1
sT1
F
ΔV
ΔP
++
+
=
++
−
+
+
=
1539pk
PM - 24
Turbine ResponseTurbine Response
The response of a tandem-compound turbine to a
ramp down of the CV opening is shown in Figure
9.22.
 has no peculiarity such as that exhibited by a
hydraulic turbine due to water inertia
 governing requirements more straightforward
Figure 9.22: Steam turbine response to a 1-second ramp
change in CV opening
TRH=7.0 s, FHP=0.3; TCH and TCO negligible
1539pk
PM - 25
Steam Turbine ControlsSteam Turbine Controls
Functions:
 The governing systems have three basic functions:
 normal speed/load control
 overspeed control
 overspeed trip
In addition, the turbine controls include a number of
other functions such as start-up/shut-down controls
and auxiliary pressure control
 The speed/load control is a fundamental requirement
 achieved through control of CVs
 the speed control function provides the governor with a
4 to 5% speed drop
 the load control function achieved by adjusting
speed/load reference
 The overspeed control and protection is peculiar to
steam turbines
 of critical importance for safe operation
 speed should be limited to well below the design
maximum speed of 120%
1539pk
PM - 26
 The overspeed control is the first line of defense
 involves fast control of CVs and IVs
 limits overspeed following load rejection to 0.5 to 1.0%
below overspeed trip level
 returns the turbine to a steady-state condition with
turbine ready for reloading
 The overspeed or emergency trip is a backup
protection
 designed to be independent of the overspeed control
 fast closes the main and reheat stop valves, and trips
the boiler
 The characteristics of steam valves are highly
nonlinear
 compensation is often used to linearize steam flow
response to the control signal
 compensation may be achieved by a forward loop
series compensation, a minor loop feedback, or a
major loop feedback.
1539pk
PM - 27
Governing Systems
 Systems used for the above control functions have
evolved over the years:
 older units used mechanical-hydraulic control
 electro-hydraulic control was introduced in the 1960s
 most governors supplied today are electro-hydraulic
or digital electro-hydraulic
1539pk
PM - 28
 The functional block diagram of a mechanical-
hydraulic control (MHC) system is shown in Figure
9.25
 the speed governor is a mechanical transducer which
transformers speed into position output
 the speed relay is a spring loaded servomotor which
amplifies the speed governor signal
 the hydraulic servomotor provides additional
amplification to the energy level necessary to move
the steam valves
 Figure 9.31 shows the block diagram of an MHC
speed governing system, including the overspeed
control (auxiliary governor) applicable to a specific
make
Figure 9.25: Functional block diagram of MHC turbine
governing system
1539pk
PM - 29
Figure 9.31: MHC turbine governing system with auxiliary
governor
1539pk
PM - 30
 The electro-hydraulic control (EHC) systems use
electronic circuits in place of mechanical
components associated with the MHC in the low-
power portions
 offer more flexibility and adaptability
Fig. 9.33 shows an example of EHC governing
system. It has two special features for limiting
overspeed: IV trigger and power load unbalance
(PLU) relay.
 the IV trigger is armed when the load (measured
by reheat pressure) is greater than 0.1 p.u. It is
designed to fast close IVs when the speed
exceeds set value.
 the PLU relay is designed to fast close CVs and
IVs under load rejection conditions. It trips when
the difference between turbine power and
generator load exceeds a preset value (0.4 p.u.)
and the load decreases faster than a preset rate.
1539pk
PM - 31
Fig. 9.33 EHC governing system with PLU relay and IV
trigger
1539pk
PM - 32
3. Gas Turbines3. Gas Turbines
 The heat source is a hydrocarbon-based fuel
 in either gaseous or liquid state
 fuel is burned directly in the working fluid
 like any internal combustion engine, requires external
source for startup
 The power produced by the gas turbine is used to
drive an alternator to produce electrical power at
frequencies compatible with local grids
 Exhaust heat is often used to generate steam, which
can be used for a process, as in the case of
cogeneration
 simple-cycle configuration
 Alternatively, steam produced using exhaust heat
can be used in a steam turbine to generate additional
electrical power
 combined-cycle configuration
 Many variations in configurations and controls
 no standard models
 CIGRE TF: 38.02.25 report published in April 2003
addresses modeling issues

More Related Content

What's hot

Turbine Governing System
Turbine Governing SystemTurbine Governing System
Turbine Governing System
Salil Vaidya
 
Lecture 2 transfer-function
Lecture 2 transfer-functionLecture 2 transfer-function
Lecture 2 transfer-function
Saifullah Memon
 

What's hot (20)

Turbine Governing System
Turbine Governing SystemTurbine Governing System
Turbine Governing System
 
Combined Cycle Power Plant
Combined Cycle Power PlantCombined Cycle Power Plant
Combined Cycle Power Plant
 
Electric drive
Electric driveElectric drive
Electric drive
 
STEAM AND GAS TURBINES ppt
STEAM AND GAS TURBINES pptSTEAM AND GAS TURBINES ppt
STEAM AND GAS TURBINES ppt
 
Gas turbine cycle (open and closed gas turbine cycle)
Gas turbine cycle (open and closed gas turbine cycle)Gas turbine cycle (open and closed gas turbine cycle)
Gas turbine cycle (open and closed gas turbine cycle)
 
Presentation on starter
Presentation on starterPresentation on starter
Presentation on starter
 
importance of reactive power in power system
importance of reactive power in power systemimportance of reactive power in power system
importance of reactive power in power system
 
Breaking,Types of Electrical Braking system, Regenerative Braking, Plugging ...
Breaking,Types of Electrical Braking system, Regenerative Braking,  Plugging ...Breaking,Types of Electrical Braking system, Regenerative Braking,  Plugging ...
Breaking,Types of Electrical Braking system, Regenerative Braking, Plugging ...
 
Automatic Generation Control
Automatic Generation ControlAutomatic Generation Control
Automatic Generation Control
 
Starting method of induction motors
Starting method of induction motorsStarting method of induction motors
Starting method of induction motors
 
Steam turbine
Steam turbineSteam turbine
Steam turbine
 
Swing equation
Swing equationSwing equation
Swing equation
 
[PPT] on Steam Turbine
[PPT] on Steam Turbine[PPT] on Steam Turbine
[PPT] on Steam Turbine
 
3 phase Induction Motor Torque-slip characteristics and Related problems
3 phase Induction Motor Torque-slip characteristics and Related problems3 phase Induction Motor Torque-slip characteristics and Related problems
3 phase Induction Motor Torque-slip characteristics and Related problems
 
Introduction to Electrical Drive
Introduction to Electrical DriveIntroduction to Electrical Drive
Introduction to Electrical Drive
 
Lecture 2 transfer-function
Lecture 2 transfer-functionLecture 2 transfer-function
Lecture 2 transfer-function
 
Alternator protection
Alternator protectionAlternator protection
Alternator protection
 
Electric drive
Electric driveElectric drive
Electric drive
 
DFIG_report
DFIG_reportDFIG_report
DFIG_report
 
TRANSIENT ANGLE STABILITY
TRANSIENT ANGLE STABILITYTRANSIENT ANGLE STABILITY
TRANSIENT ANGLE STABILITY
 

Similar to 02 3 prime-movers

Iaetsd load frequency control for a distributed grid
Iaetsd load frequency control for a distributed gridIaetsd load frequency control for a distributed grid
Iaetsd load frequency control for a distributed grid
Iaetsd Iaetsd
 
NTPC _Traning report_dhiraj
NTPC _Traning report_dhirajNTPC _Traning report_dhiraj
NTPC _Traning report_dhiraj
Dhiraj Kumar
 

Similar to 02 3 prime-movers (20)

PRIME MOVERS & GOVERNING SYSTEMS
PRIME MOVERS & GOVERNING SYSTEMSPRIME MOVERS & GOVERNING SYSTEMS
PRIME MOVERS & GOVERNING SYSTEMS
 
PRIME MOVERS AND GOVERNING SYSTEMS
PRIME MOVERS AND GOVERNING SYSTEMSPRIME MOVERS AND GOVERNING SYSTEMS
PRIME MOVERS AND GOVERNING SYSTEMS
 
Iaetsd load frequency control for a distributed grid
Iaetsd load frequency control for a distributed gridIaetsd load frequency control for a distributed grid
Iaetsd load frequency control for a distributed grid
 
Automatic generation control&voltage control(module 5:ktu syllabus)
Automatic generation control&voltage control(module 5:ktu syllabus)Automatic generation control&voltage control(module 5:ktu syllabus)
Automatic generation control&voltage control(module 5:ktu syllabus)
 
Pelton turbine
Pelton turbinePelton turbine
Pelton turbine
 
Steam turbines
Steam turbinesSteam turbines
Steam turbines
 
Report hydroelectric power plant
Report hydroelectric power plantReport hydroelectric power plant
Report hydroelectric power plant
 
Lecture 3.1 Turbines in Micro Hydro
Lecture 3.1 Turbines in Micro HydroLecture 3.1 Turbines in Micro Hydro
Lecture 3.1 Turbines in Micro Hydro
 
1 8
1 81 8
1 8
 
Affinity Laws for Variable Speed Centrifugal Pumps
Affinity Laws for Variable Speed Centrifugal PumpsAffinity Laws for Variable Speed Centrifugal Pumps
Affinity Laws for Variable Speed Centrifugal Pumps
 
1 8
1 81 8
1 8
 
B035208015
B035208015B035208015
B035208015
 
Hydraulic Turbines
Hydraulic TurbinesHydraulic Turbines
Hydraulic Turbines
 
CH4 Turbine selection.pptx
CH4 Turbine selection.pptxCH4 Turbine selection.pptx
CH4 Turbine selection.pptx
 
NTPC _Traning report_dhiraj
NTPC _Traning report_dhirajNTPC _Traning report_dhiraj
NTPC _Traning report_dhiraj
 
Internship Report
Internship ReportInternship Report
Internship Report
 
3. water turbine (intro)
3. water turbine (intro)3. water turbine (intro)
3. water turbine (intro)
 
Betz speed limit and tip speed ratio
Betz speed limit and tip speed ratioBetz speed limit and tip speed ratio
Betz speed limit and tip speed ratio
 
Turbomachine Module03.pptx
Turbomachine Module03.pptxTurbomachine Module03.pptx
Turbomachine Module03.pptx
 
Propulsion 2 notes
Propulsion 2 notesPropulsion 2 notes
Propulsion 2 notes
 

Recently uploaded

Reboulia: features, anatomy, morphology etc.
Reboulia: features, anatomy, morphology etc.Reboulia: features, anatomy, morphology etc.
Reboulia: features, anatomy, morphology etc.
Silpa
 
Asymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 b
Asymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 bAsymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 b
Asymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 b
Sérgio Sacani
 
LUNULARIA -features, morphology, anatomy ,reproduction etc.
LUNULARIA -features, morphology, anatomy ,reproduction etc.LUNULARIA -features, morphology, anatomy ,reproduction etc.
LUNULARIA -features, morphology, anatomy ,reproduction etc.
Silpa
 
Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune WaterworldsBiogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
Sérgio Sacani
 
development of diagnostic enzyme assay to detect leuser virus
development of diagnostic enzyme assay to detect leuser virusdevelopment of diagnostic enzyme assay to detect leuser virus
development of diagnostic enzyme assay to detect leuser virus
NazaninKarimi6
 
Digital Dentistry.Digital Dentistryvv.pptx
Digital Dentistry.Digital Dentistryvv.pptxDigital Dentistry.Digital Dentistryvv.pptx
Digital Dentistry.Digital Dentistryvv.pptx
MohamedFarag457087
 
(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...
(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...
(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...
Scintica Instrumentation
 
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
?#DUbAI#??##{{(☎️+971_581248768%)**%*]'#abortion pills for sale in dubai@
 
Human genetics..........................pptx
Human genetics..........................pptxHuman genetics..........................pptx
Human genetics..........................pptx
Silpa
 

Recently uploaded (20)

Thyroid Physiology_Dr.E. Muralinath_ Associate Professor
Thyroid Physiology_Dr.E. Muralinath_ Associate ProfessorThyroid Physiology_Dr.E. Muralinath_ Associate Professor
Thyroid Physiology_Dr.E. Muralinath_ Associate Professor
 
PSYCHOSOCIAL NEEDS. in nursing II sem pptx
PSYCHOSOCIAL NEEDS. in nursing II sem pptxPSYCHOSOCIAL NEEDS. in nursing II sem pptx
PSYCHOSOCIAL NEEDS. in nursing II sem pptx
 
Cyanide resistant respiration pathway.pptx
Cyanide resistant respiration pathway.pptxCyanide resistant respiration pathway.pptx
Cyanide resistant respiration pathway.pptx
 
Reboulia: features, anatomy, morphology etc.
Reboulia: features, anatomy, morphology etc.Reboulia: features, anatomy, morphology etc.
Reboulia: features, anatomy, morphology etc.
 
Asymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 b
Asymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 bAsymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 b
Asymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 b
 
Grade 7 - Lesson 1 - Microscope and Its Functions
Grade 7 - Lesson 1 - Microscope and Its FunctionsGrade 7 - Lesson 1 - Microscope and Its Functions
Grade 7 - Lesson 1 - Microscope and Its Functions
 
FAIRSpectra - Enabling the FAIRification of Analytical Science
FAIRSpectra - Enabling the FAIRification of Analytical ScienceFAIRSpectra - Enabling the FAIRification of Analytical Science
FAIRSpectra - Enabling the FAIRification of Analytical Science
 
Human & Veterinary Respiratory Physilogy_DR.E.Muralinath_Associate Professor....
Human & Veterinary Respiratory Physilogy_DR.E.Muralinath_Associate Professor....Human & Veterinary Respiratory Physilogy_DR.E.Muralinath_Associate Professor....
Human & Veterinary Respiratory Physilogy_DR.E.Muralinath_Associate Professor....
 
LUNULARIA -features, morphology, anatomy ,reproduction etc.
LUNULARIA -features, morphology, anatomy ,reproduction etc.LUNULARIA -features, morphology, anatomy ,reproduction etc.
LUNULARIA -features, morphology, anatomy ,reproduction etc.
 
Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune WaterworldsBiogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
 
Molecular markers- RFLP, RAPD, AFLP, SNP etc.
Molecular markers- RFLP, RAPD, AFLP, SNP etc.Molecular markers- RFLP, RAPD, AFLP, SNP etc.
Molecular markers- RFLP, RAPD, AFLP, SNP etc.
 
development of diagnostic enzyme assay to detect leuser virus
development of diagnostic enzyme assay to detect leuser virusdevelopment of diagnostic enzyme assay to detect leuser virus
development of diagnostic enzyme assay to detect leuser virus
 
Bhiwandi Bhiwandi ❤CALL GIRL 7870993772 ❤CALL GIRLS ESCORT SERVICE In Bhiwan...
Bhiwandi Bhiwandi ❤CALL GIRL 7870993772 ❤CALL GIRLS  ESCORT SERVICE In Bhiwan...Bhiwandi Bhiwandi ❤CALL GIRL 7870993772 ❤CALL GIRLS  ESCORT SERVICE In Bhiwan...
Bhiwandi Bhiwandi ❤CALL GIRL 7870993772 ❤CALL GIRLS ESCORT SERVICE In Bhiwan...
 
Factory Acceptance Test( FAT).pptx .
Factory Acceptance Test( FAT).pptx       .Factory Acceptance Test( FAT).pptx       .
Factory Acceptance Test( FAT).pptx .
 
Digital Dentistry.Digital Dentistryvv.pptx
Digital Dentistry.Digital Dentistryvv.pptxDigital Dentistry.Digital Dentistryvv.pptx
Digital Dentistry.Digital Dentistryvv.pptx
 
CURRENT SCENARIO OF POULTRY PRODUCTION IN INDIA
CURRENT SCENARIO OF POULTRY PRODUCTION IN INDIACURRENT SCENARIO OF POULTRY PRODUCTION IN INDIA
CURRENT SCENARIO OF POULTRY PRODUCTION IN INDIA
 
(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...
(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...
(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...
 
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
 
PATNA CALL GIRLS 8617370543 LOW PRICE ESCORT SERVICE
PATNA CALL GIRLS 8617370543 LOW PRICE ESCORT SERVICEPATNA CALL GIRLS 8617370543 LOW PRICE ESCORT SERVICE
PATNA CALL GIRLS 8617370543 LOW PRICE ESCORT SERVICE
 
Human genetics..........................pptx
Human genetics..........................pptxHuman genetics..........................pptx
Human genetics..........................pptx
 

02 3 prime-movers

  • 1. 1539pk PRIME MOVERS AND GOVERNINGPRIME MOVERS AND GOVERNING SYSTEMSSYSTEMS Copyright © P. Kundur This material should not be used without the author's consent
  • 2. 1539pk PM - 2 Prime Movers and Governing SystemsPrime Movers and Governing Systems 1. Hydraulic Turbines and Governing Systems  hydraulic turbine transfer function  special characteristics of hydraulic turbines  nonlinear hydraulic turbine model  governors for hydraulic turbines  tuning of speed governors 2. Steam Turbines and Governing Systems  steam turbine configurations  steam turbine models  steam turbine controls 3. Gas Turbines and Governing Systems  simple-cycle configuration  combined-cycle configuration Outline
  • 3. 1539pk PM - 3 Hydraulic Turbines and GoverningHydraulic Turbines and Governing SystemsSystems  The performance of a hydraulic turbine is influenced by the characteristics of the water column feeding the turbine:  water inertia  water compressibility  pipe wall elasticity in the penstock  The effect of water inertia is to cause changes in turbine flow to lag behind changes in turbine gate opening  The effect of elasticity is to cause traveling waves of pressure and flow in the pipe - a phenomenon referred to as water hammer  typically, the speed of propagation of such waves is about 1200 meters/sec  traveling wave model required only if penstock is very long
  • 4. 1539pk PM - 4  The representation of the hydraulic turbine and water column in stability studies usually assumes that (a) the penstock is inelastic, (b) the water is incompressible, and (c) hydraulic resistance is negligible  The turbine and penstock characteristics are determined by three basic equations relating to:  velocity of water in the penstock  turbine mechanical power  acceleration of water column 1. Hydraulic Turbine Transfer Function1. Hydraulic Turbine Transfer Function Figure 9.2: Schematic of a hydroelectric plant
  • 5. 1539pk PM - 5 The velocity of the water in the penstock is given by where U = water velocity G = gate position H = hydraulic head at gate Ku = a constant of proportionality The turbine mechanical power is proportional to the product of pressure and flow; hence, The acceleration of water column due to a change in head at the turbine, characterized by Newton's second law of motion, may be expressed as where L = length of conduit A = pipe area ρ = mass density ag = acceleration due to gravity ρLA = mass of water in the conduit ρag∆H = incremental change in pressure at turbine gate HGKU u= HUKP pm = ( ) ( ) HaA dt Ud LA g ∆ρ−= ∆ ρ
  • 6. 1539pk PM - 6  For small displacements (prefix ∆) about an initial operating point (subscript "0") we can shows that where  Tw is referred to as the water starting time. It represents the time required for a head H0 to accelerate the water in the penstock from standstill to the velocity U0. It should be noted that Tw varies with load. Typically, Tw at full load lies between 0.5 s and 4.0 s.  Equation 9.11 represents the "classical" transfer function of the turbine-penstock system. It shows how the turbine power output changes in response to a change in gate opening for an ideal lossless turbine. ST 2 1 1 ST1 G P w wm + − = ∆ ∆ 0g 0 w Ha LU T = (9.11)
  • 7. 1539pk PM - 7 Special Characteristics of Hydraulic Turbines  The transfer function given by Equation 9.11 represents a "non-minimum phase" system Systems with poles or zeros in the right half of s-plane are referred to as non-minimum phase systems; they do not have the minimum amount of phase shift for a given magnitude plot. Such systems cannot be uniquely identified by a knowledge of magnitude versus frequency plot alone.  The special characteristic of the transfer function may be illustrated by considering the response to a step change in gate position. The time response is given by:  Figure 9.3 shows a plot of the response of an ideal turbine model with Tw = 4.0 s ( ) Ge31tP t T 2 m w ∆         −=∆      −
  • 8. 1539pk PM - 8 Figure 9.3: Change in turbine mechanical power following a unit step increase in gate position
  • 9. 1539pk PM - 9  Immediately following a unit increase in gate position, the mechanical power actually decreases by 2.0 per unit. It then increases exponentially with a time constant of Tw/2 to a steady state value of 1.0 per unit above the initial steady state value  The initial power surge is opposite to that of the direction of change in gate position. This is because, when the gate is suddenly opened, the flow does not change immediately due to water inertia; however, the pressure across the turbine is reduced causing the power to reduce.  With a response determined by Tw, the water accelerates until the flow reaches the new steady value which establishes the new steady power output
  • 10. 1539pk PM - 10 Governors for Hydraulic TurbinesGovernors for Hydraulic Turbines  The speed/load control function involves feeding back speed error to control the gate position. In order to ensure satisfactory and stable parallel operation of multiple units, the speed governor is provided with a droop characteristic.  Typically, the steady state droop is set at about 5%, such that a speed deviation of 5% causes 100% change in gate position or power output; this corresponds to a gain of 20.  For a hydro turbine, however, such a governor with a simple steady state droop characteristic would be unsatisfactory Requirement for a Transient Droop  Hydro turbines have a peculiar response due to water inertia: a change in gate position produces an initial turbine power change which is opposite to that sought.  For stable control performance, a large transient (temporary) droop with a long resetting time is therefore required. This is accomplished by the provision of a rate feedback or transient gain reduction compensation as shown in Figure 9.8
  • 11. 1539pk PM - 11  The rate feedback retards or limits the gate movement until the water flow and power output have time to catch up  The result is a governor which exhibits a high droop (low gain) for fast speed deviations, and the normal low droop (high gain) in the steady state Figure 9.8: Governor with transient droop compensation
  • 12. 1539pk PM - 12 Mechanical Hydraulic GovernorMechanical Hydraulic Governor  On older units, the governing function is realized using mechanical and hydraulic components  Speed sensing, permanent droop feedback, and computing functions are achieved through mechanical components; functions involving higher power are achieved through hydraulic components  A dashpot is used to provide transient droop compensation. A bypass arrangement is usually provided to disable the dashpot if so desired.  Water is not a very compressible fluid; if the gate is closed too rapidly the resulting pressure could burst the penstock  Consequently, the gate movement is rate limited  Often, the rate of gate movement is limited even further in the buffer region near full closure to provide cushioning
  • 13. 1539pk PM - 13 Figure 9.9: Schematic of a mechanical-hydraulic governor for a hydro turbine
  • 14. 1539pk PM - 14 Parameters Sample data Tp = Pilot valve and servomotor time constant 0.05 s Ks = Servo gain 5.0 TG = Main servo time 0.2 s Rp = Permanent droop 0.04 RT = Temporary droop 0.4 TR = Reset time 5.0 s Constraints Maximum gate position limit = 1.0 Minimum gate position limit = 0 Rmax open = Maximum gate opening rate 0.16 p.u./s Rmax close = Maximum gate closing rate 0.16 p.u./s Rmax buff = Maximum gate closing rate in buffered region 0.04 p.u./s gbuff = Buffered region in p.u. of servomotor stroke 0.08 p.u. Figure 9.10: Model of governors for hydraulic turbines
  • 15. 1539pk PM - 15 Electro-Hydraulic GovernorElectro-Hydraulic Governor  Modern speed governors for hydraulic turbines use electric-hydraulic systems. Functionally, their operation is very similar to those of mechanical- hydraulic governors  Speed sensing, permanent droop, temporary droop, and other measuring and computing functions are performed electrically  Electric components provide greater flexibility and improved performance with regard to dead-bands and time lags  Dynamic characteristics of electric governors are usually adjusted to be essentially similar to those of mechanical-hydraulic governors
  • 16. 1539pk PM - 16 Tuning of Speed Governing SystemsTuning of Speed Governing Systems  There are two important considerations in the selection of governor settings:  Stable operation during system islanding conditions or isolated operation; and  Acceptable speed of response for loading and unloading under normal synchronous operation  For stable operation under islanding conditions, the optimum choice of the temporary droop RT and reset time TR are as follows:  For loading and unloading during normal interconnected system operation, the above settings result in too slow a response. For satisfactory loading rates, the reset time TR should be less than 1.0 s, preferably close to 0.5 s.  The dashpot bypass arrangement can be used to meet the above conflicting requirements ( )[ ] M w wT T T 15.00.1T3.2R −−= ( )[ ] wwR T5.00.1T0.5T −−=
  • 17. 1539pk PM - 17 2. Steam Turbines and Governing2. Steam Turbines and Governing SystemsSystems  A steam turbine converts stored energy of high pressure and high temperature steam into rotating energy  the heat source may be a nuclear reactor or a fossil fired boiler  Steam turbines with a variety of configurations have been built depending on unit size and steam conditions  normally consist of two or more turbine sections or cylinders coupled in series  A turbine with multiple sections may be  tandem-compound: sections are all on one shaft with a single generator, or  cross-compound: sections are on two shafts, each with a generator; operated as a single unit  Fossil-fuelled units can be of tandem-compound or cross-compound design  may be of reheat or non-reheat type
  • 18. 1539pk PM - 18 Figure 9.16: Common configurations of tandem-compound steam turbine of fossil-fueled units
  • 19. 1539pk PM - 19 Figure 9.17: Examples of cross-compound steam turbine configurations
  • 20. 1539pk PM - 20  Nuclear units usually have tandem-compound turbines  moisture separator reheater (MSR) reduces moisture content, thereby reducing moisture losses and erosion rates  Large steam turbines for fossil-fuelled or nuclear units are equipped with four sets of valves  main inlet stop valves (MSV)  main inlet control (governor) valves (CV)  reheater stop valves (RSV)  reheater intercept valves (IV)  The stop valves (MSV and RSV) are primarily emergency trip valves.  The CVs modulate steam flow during normal operation.  The CVs as well as the IVs limit overspeed. Figure 9.18: An example of nuclear unit turbine configuration
  • 21. 1539pk PM - 21 Steam Turbine ModelSteam Turbine Model  For illustration, let us consider a fossil-fuelled single reheat tandem-compound turbine, a type in common use  Figure 9.21(a) identifies the turbine elements that need to be considered  Figure 9.21(b) shows the block diagram representation  The CVs modulate the steam flow for load/frequency control  the response of steam flow to CV opening exhibits a time constant TCH due to charging time of the steam chest and inlet piping  TCH is of the order of 0.2 to 0.3 s  The IVs are used only for rapid control of turbine power in the event of an overspeed  control about 70% of total power  the steam flow in the IP and LP sections can change only with the build-up of pressure in the reheater volume  the reheater time constant TRH is in the range 5 to 10 s  the steam flow in LP sections experiences a time constant TCO associated with the crossover piping; this is of the order of 0.5 s
  • 22. 1539pk PM - 22 Parameters TCH = time constant of main inlet volumes and steam chest TRH = time constant of reheater TCO = time constant of crossover piping and LP inlet volumes Pm = total turbine power in per unit of maximum turbine power Pmc = total turbine mechanical power in per unit of common MVA base PMAX = maximum turbine power in MW FHP,FIP,FLP = fraction of total turbine power generated by HP, IP, LP sections, respectively MVAbase = common MVA base Figure 9.21: Single reheat tandem-compound steam turbine model
  • 23. 1539pk PM - 23 Simplified Transfer Function of a SteamSimplified Transfer Function of a Steam TurbineTurbine A simplified transfer function of the turbine relating perturbed values of the turbine power and CV position may be written as follows: It is assumed that TCO is negligible in comparison with TRH, and that the CV characteristic is linear ( )( ) ( )( )RHCH RHHP RHCH HP CH HP CV m sT1sT1 TsF1 sT1sT1 F1 sT1 F ΔV ΔP ++ + = ++ − + + =
  • 24. 1539pk PM - 24 Turbine ResponseTurbine Response The response of a tandem-compound turbine to a ramp down of the CV opening is shown in Figure 9.22.  has no peculiarity such as that exhibited by a hydraulic turbine due to water inertia  governing requirements more straightforward Figure 9.22: Steam turbine response to a 1-second ramp change in CV opening TRH=7.0 s, FHP=0.3; TCH and TCO negligible
  • 25. 1539pk PM - 25 Steam Turbine ControlsSteam Turbine Controls Functions:  The governing systems have three basic functions:  normal speed/load control  overspeed control  overspeed trip In addition, the turbine controls include a number of other functions such as start-up/shut-down controls and auxiliary pressure control  The speed/load control is a fundamental requirement  achieved through control of CVs  the speed control function provides the governor with a 4 to 5% speed drop  the load control function achieved by adjusting speed/load reference  The overspeed control and protection is peculiar to steam turbines  of critical importance for safe operation  speed should be limited to well below the design maximum speed of 120%
  • 26. 1539pk PM - 26  The overspeed control is the first line of defense  involves fast control of CVs and IVs  limits overspeed following load rejection to 0.5 to 1.0% below overspeed trip level  returns the turbine to a steady-state condition with turbine ready for reloading  The overspeed or emergency trip is a backup protection  designed to be independent of the overspeed control  fast closes the main and reheat stop valves, and trips the boiler  The characteristics of steam valves are highly nonlinear  compensation is often used to linearize steam flow response to the control signal  compensation may be achieved by a forward loop series compensation, a minor loop feedback, or a major loop feedback.
  • 27. 1539pk PM - 27 Governing Systems  Systems used for the above control functions have evolved over the years:  older units used mechanical-hydraulic control  electro-hydraulic control was introduced in the 1960s  most governors supplied today are electro-hydraulic or digital electro-hydraulic
  • 28. 1539pk PM - 28  The functional block diagram of a mechanical- hydraulic control (MHC) system is shown in Figure 9.25  the speed governor is a mechanical transducer which transformers speed into position output  the speed relay is a spring loaded servomotor which amplifies the speed governor signal  the hydraulic servomotor provides additional amplification to the energy level necessary to move the steam valves  Figure 9.31 shows the block diagram of an MHC speed governing system, including the overspeed control (auxiliary governor) applicable to a specific make Figure 9.25: Functional block diagram of MHC turbine governing system
  • 29. 1539pk PM - 29 Figure 9.31: MHC turbine governing system with auxiliary governor
  • 30. 1539pk PM - 30  The electro-hydraulic control (EHC) systems use electronic circuits in place of mechanical components associated with the MHC in the low- power portions  offer more flexibility and adaptability Fig. 9.33 shows an example of EHC governing system. It has two special features for limiting overspeed: IV trigger and power load unbalance (PLU) relay.  the IV trigger is armed when the load (measured by reheat pressure) is greater than 0.1 p.u. It is designed to fast close IVs when the speed exceeds set value.  the PLU relay is designed to fast close CVs and IVs under load rejection conditions. It trips when the difference between turbine power and generator load exceeds a preset value (0.4 p.u.) and the load decreases faster than a preset rate.
  • 31. 1539pk PM - 31 Fig. 9.33 EHC governing system with PLU relay and IV trigger
  • 32. 1539pk PM - 32 3. Gas Turbines3. Gas Turbines  The heat source is a hydrocarbon-based fuel  in either gaseous or liquid state  fuel is burned directly in the working fluid  like any internal combustion engine, requires external source for startup  The power produced by the gas turbine is used to drive an alternator to produce electrical power at frequencies compatible with local grids  Exhaust heat is often used to generate steam, which can be used for a process, as in the case of cogeneration  simple-cycle configuration  Alternatively, steam produced using exhaust heat can be used in a steam turbine to generate additional electrical power  combined-cycle configuration  Many variations in configurations and controls  no standard models  CIGRE TF: 38.02.25 report published in April 2003 addresses modeling issues