Generative Artificial Intelligence: How generative AI works.pdf
Sun fire x2100 m2 and x2200 m2 technical presentation
1. Sun Fire X2100/X2200 M2 Technical
Product Training Presentation
SunWin Token # 478550
Ronald Graham
Systems Group Technical Marketing
Sun Microsystems
2. Agenda
• Introduction and Positioning
• Server Architecture
> Sun Fire X2200
> Sun Fire X2100
> Enabling Technologies
• Embedded Light Out Management
• Operating Systems
• System and Upgrade Options
2 Sun Confidential : Sun/Partners Use Only
3. Sun’s x64 System Portfolio
Systems Refresh Throughout 2008
Sun Grid Sun Blade 6048
Rack System Sun Blade 8000
Sun Blade 6000
Voted
“Best High Perf
First & Only Server” Sun Fire New
8-socket/16-way InfoWorld Sun Fire X4500 Hybrid Data
AMD Server X4600 X4540 Server
Sun Fire X4250 Sun Fire X4450
Sun Fire X4150
Sun Fire X4140 Sun Fire X4440 Sun Fire
X4200 Voted
X4240 X4100 “Best Enterprise
Server”
InfoWorld
Sun Fire X2100 Sun Fire X2250 Sun Fire X2200
Ultra 40 Ultra 20
3 Sun Confidential : Sun/Partners Use Only
4. Sun Fire Features Summary
Features Sun Fire X2100 M2 Sun Fire X2200 M2
Form Factor 1U 1U
Processor 1x Dual-Core AMD Opteron processor Model 1200 CPU Up to 2 Dual-Core or Quad-Core AMD Opteron 2000 series processors
w/ 1MB L2 Cache per Core w/ 4x 128 KB L1, 4x 512 KB L2, and 2MB or 6MB of shared L3 Cache
BIOS AMI BIOS AMI BIOS
Memory DIMM slots 4 DIMM slots 8 DIMM slots per CPU
Memory Types DDR-2 667MHz Un-bufferred DIMMs with ECC DDR-2 667MHz Registered DIMMs with ECC
Memory Module Sizes 512MB, 1GB, 2GB DIMMs 1GB,2GB, 4GB DIMMs
Max Memory 8 GB 64 GB
HDD Controller Integrated Nvidia MCP55 Integrated Nvidia MCP55
Serial ATA II Serial ATA II
HDD Type 3.5-inch drives 3.5-inch drives
HDD Number 2 HDDs 2 HDDs
Optical Drive DVD-ROM DVD-ROM
NIC Controller Dual Integrated nVidia MCP55 Dual Integrated nVidia MCP55
Broadcom BCM5715C Broadcom BCM5715C
NICs Four Gigabit Ethernet NICs Four Gigabit Ethernet NICs
Graphics Controller AST2000 AST2000
Expansion Slots Two PCI-E x8 Slots Two PCI-E x8 Slots
(or One PCI-E x16 Slot by optional Riser Q4CY06) (or One PCI-E x16 Slot by optional Riser Q4CY06)
Front I/O Six USB 2.0 ports Six USB 2.0 ports
Four Gigabit Ethernet ports (RJ45) Four Gigabit Ethernet ports (RJ45)
One RS-232 Serial (DB9) One RS-232 Serial (DB9)
Rear I/O Four USB 2.0 ports (Type A) Four USB 2.0 ports (Type A)
VGA Video port (HD15) VGA Video port (HD15)
Power supply Single 345Watt Single 450Watt
Service Processor supporting Graphics redirection, Remote Service Processor supporting Graphics redirection, Remote
Systems Management Floppy/CD/DVD, IPMI 2.0, SNMP, CLI and Web interface Floppy/CD/DVD, IPMI 2.0, SNMP, CLI and Web interface
OS Support Solaris, Linux and Windows Solaris, Linux, Windows, and VMware
4 Sun Confidential : Sun/Partners Use Only
5. Agenda
• Introduction and Positioning
• Server Architecture
> Sun Fire X2200
> Sun Fire X2100
> Enabling Technologies
• Embedded Light Out Management
• Operating Systems
• System Options
5 Sun Confidential : Sun/Partners Use Only
6. Sun Fire X2200 M2
The 1U Server Workhorse Compute
●
Dual- or Quad-Core
●
1 or 2 AMD Opteron™ 2000 series processors
●
1U-rackmount
●
Up to 64GB with 16 DIMM Slots (4 GB DIMMs)
I/O
●
2 x 8-lane PCI Express slots (Optional 1 x 16-Lane)
●
4 x GigE standard, USB 2.0, Video, Serial ports
● DVD
●
Up to 2 TB of storage with 2 x SATA 3.5” disk drives
Availability
Hot-pluggable disk
One of the Industry's Fastest 2-socket Server for
●
●
RAID 0 or 1 (Optional)
processing memory-intensive applications Management
●
Embedded LOM Service Processor
Ideal for Web Infrastructure, HPC, ●
Remote power on/off/status, GUI+CLI, IPMI 2.0, SNMP
Simulations, Financial Modeling ●
Remote KVM, Floppy/CDROM
Excellent for EDA Operating Environment
●
Solaris, Linux, Windows, Vmware
6 Sun Confidential : Sun/Partners Use Only
7. Sun Fire X2200 M2 System Layout
7 Sun Confidential : Sun/Partners Use Only
8. X2200 Architectural Block Diagram
8
SATA II only
8
DDR-2 AMD Opteron 2000 DDR-2 Rear
DIMMS AMD Opteron 2000
Series CPU Series CPU DIMMS Panel
Slots Slots
Marvell nVidia
DDR-2 DDR-2 nVidia NIC 1 88E1121 NIC 0
5.3GB/s 5.3GB/s PHY
HT bus Marvell
88E1121 nVidia
DDR-2 (8GB/s) DDR-2 NIC 1
5.3GB/s 5.3GB/s nVidia NIC 0 PHY
HT bus (8GB/s) Rear
4 x USB 2.0 USB
Ports
x16 PCI-E bus (4GB/s)
Dual x8 PCI-E Riser
USB 2.0
or Serial
USB 2.0 Port
Single x16 PCI-E Riser Serial
MCP55
DB9
PCI 32bit/33MHz Rear
SATA II 3.0Gb/s VGA VGA
LPC bus Video HD15
SATA II 3.0Gb/s UMP
Port
BIOS SuperIO
2 x USB 2.0 Ultra FLASH Legacy BCM
ATA 133 PROM Device NIC 0
x4 PCI-E bus (1GB/s) BCM
Front NIC 1
Panel
3.5”SATA 3.5”SATA Shared
Disk Drive Disk Drive Front Panel Tray Load ELOM NIC
DVD ROM
USB Ports Confidential : Sun/Partners Use Only
8 Sun Port
9. X2200 Architectural Block Diagram
HBA – SATA II or SAS
8 8
DDR-2 AMD Opteron 2000 DDR-2 Rear
DIMMS AMD Opteron 2000
Series CPU Series CPU DIMMS Panel
Slots Slots
Marvell nVidia
DDR-2 DDR-2 nVidia NIC 1 88E1121 NIC 0
5.3GB/s 5.3GB/s PHY
HT bus Marvell
88E1121 nVidia
DDR-2 (8GB/s) DDR-2 NIC 1
5.3GB/s 5.3GB/s nVidia NIC 0 PHY
HT bus (8GB/s) Rear
Single x16 PCIe Riser 4 x USB 2.0 USB
or Ports
Dual x8 PCIe Riser
x16 PCI-E bus (4GB/s)
USB 2.0
Serial
USB 2.0 Port
Serial
HBA MCP55
DB9
PCI 32bit/33MHz Rear
SATA II or SAS VGA VGA
LPC bus Video HD15
UMP
Port
SATA II or SAS BIOS SuperIO
Ultra FLASH Legacy BCM
2 x USB 2.0 ATA 133 PROM Device NIC 0
x4 PCIe bus (1GB/s) BCM
NIC 1
Front
3.5”SATA or 3.5”SATA or Panel Shared
Front Panel Tray Load ELOM NIC
SAS Disk Drive SAS Disk Drive DVD ROM
USB Ports Confidential : Sun/Partners Use Only
9 Sun Port
10. Sun Fire X2200 M2 Internals Tour
CPU0 & 8x CPU1 & 8x
Memory Slots PCI-Express
Memory/PCI Fans Memory Slots
Riser Area
Disk 0
Front
Panel
PCB Serial &
Video ports
CD/DVD
Drive Nvidia NICs
& USB ports
Disk 1
Broadcom
NICs
Dual CPU/memory Embedded SP nVidia MCP55 Power Supply
10 Blowers Sun Confidential : Sun/Partners Use Only
11. Sun Fire X2200 M2 Motherboard
CPU 0, x16 PCI-Express
8 x Memory Riser Slot
DIMM Sockets
CPU 1,
8 x Memory
DIMM Sockets
CPU 0
Serial &
Embedded Video ports
Lights Out
Manager (SP) Nvidia NICs
& USB ports
Broadcom
BCM5715 NIC
11
nVidia MCP55 Sun Confidential : Sun/Partners Use Only CPU 1
12. Sun Fire X2200 Processors
Second Generation Third Generation
Santa Rosa Socket F Barcelona/Shanghai
Dual-Core Quad-Core
Special Edition TDP ACP TDP ACP
SE 120W 105W 137W 105W
TDP ACP TDP ACP
Standard Parts
95W 75W 115W 75W
High Efficient TDP ACP TDP ACP
HE 68W 55W 79W 55W
TDP – Thermal Design Power ACP – Average CPU Power
12 Sun Confidential : Sun/Partners Use Only
13. AMD Model Number Overview
4 digit AMD Opteron Processor Model - 1234
Model Number communicates scalability, generation and relative performance
● 1st digit communicates scalability -- represents maximum number of processors supported
● 1-socket AMD Opteron processor = 1000 Series, Model 1xxx
● 2-socket AMD Opteron processor = 2000 Series, Model 2xxx
● 8-socket AMD Opteron processor = 8000 Series, Model 8xxx
● 2nd digit represents the generation of AMD Opteron processor
● Model 2216 is 2nd generation [DDR2, Dual-Core, Socket F (1207)] & 2-Socket capable
● Model 2356 is 3rd generation [DDR2, Quad-Core, Socket F (1207)] & 2-Socket capable
● Third generation includes Barcelona and Shanghai
● 3rd and 4th digits communicate relative performance within product line
● For example, Model 8216 would offer
● Better performance than a Model 8212
● Lower performance than a Model 8220
• Continued Drop-in Upgradeability Investment protection
• Shanghai Model numbers
• 8/2376 (2.3GHz) 8/2378 (2.4GHz),
• 8/2380 (2.5GHz) 8/2382 (2.6GHz)
• 8/2384 (2.7GHz)
13 Sun Confidential : Sun/Partners Use Only
14. Enhancements in Shanghai
Quad-Core AMD Opteron Features New in Shanghai
“Barcelona”
45nm Technology
65nm Technology Immersion Lithography
Better clock speed scaling
6MB of L3 cache
2MB of L3 cache
Better performance
HyperTransport 1.0 @ HyperTransport 3.0 @
2GT/s (8GB/s) 4.4GT/s (17.6GB/s)
Available Spring '09 (not all platforms)
AMD Smart Fetch
AMD Balanced Smart Cache Allows cores to sleep while
still providing full cache access
AMD-V with Designed for 25% fast “world switch” time
Rapid Virtualization Indexing Enhanced Rapid Virtualizaton Indexing
(More Virt-Phys translation held in cache)
Extends power savings to L3 cache
AMD CoolCore Technology
(L3 powered down when not in use)
14 Sun Confidential : Sun/Partners Use Only
15. AMD Balanced and Smart Cache
• Dedicated L1
AMD’s 64KB/64KB vs. Intel’s 32KB/32KB
Allows 2 loads per cycle versus their one
Latency 3 cycles to L1 Core 1 Core 2 Core 3 Core 4
Cache Cache Cache Cache
Control Control Control Control
• Dedicated L2
Dedicated cache to eliminate conflicts
common in shared caches
Sized to accommodate the majority of 128KB 128KB 128KB 128KB
working sets today
Latency 12 cycles to L2
512KB 512KB 512KB 512KB
• Shared L3 - New
Optimized memory use and allocation for
multi-core
Non-inclusive victim cache architecture New 6MB
Latency <38 cycles to L3
• Low latency access to external DRAM Integrated Memory Controller
(<60ns)
• Upon a full cache miss (L1, L2 & L3) data is
sub 60ns away
• All memory ranks are the same latency from
the CPU
15 Sun Confidential : Sun/Partners Use Only
16. AMD Virtualization™ (AMD-V™)
• Faster World Switch - A “world switch” is when CPU control passes from one Guest
OS, to the hypervisor, to another Guest OS (or back to the original one). Faster
switching means the CPU can get back to work on running the virtualized application.
• Rapid Virtualization Index works by caching the address translations from Guest
Virtual memory to Guest Physical memory to Host Physical memory. To translate
between each of these states can require dozens of incremental translations.
Shanghai improves Rapid Virtualization Indexing over Barcelona by caching more of
these incremental address translation steps.
●
Benefits
V V V V V V
Virtualization at hardware level M Home M
M M Home M
M
supports more users while offering Local Local
best performance
Vmware support in 3.5 Update 1 Node Node
Remote Remote
Xen support today Home Home
Local 0
1
2 Local
Node V Remote V
V V Node V
V
M M M M M M
16 Sun Confidential : Sun/Partners Use Only
17. Dual Dynamic Power Management
Compatibility Mode Dual Dynamic Power Management
●
Today’s AMD Opteron™ processor use a ●
The power for the CPU and Memory
unified voltage plane for the Memory Controller from independent voltage
Controller and Core supplies, offering greater performance and
better power management
●
Quad-Core processors can work in
unified plane motherboards but they will ●
Second-Generation AMD (Rev F) Opteron
not offer the benefits of Dual Dynamic processors are compatible with
Power Management (DDPM) described motherboards designed to support DDPM
below but they will deliver the same voltage to
2.0 GHz the CPU and Memory Controller power
2.0 GHz
CPU Power
Unified Power System Request Queue
Supply Crossbar System Request Queue
Memory Hypertrans Crossbar
Controller port Memory Controller Memory Hypertrans
Power Controller port
1.6 GHz
1.8 GHz
17 Sun Confidential : Sun/Partners Use Only
18. AMD-V Extended Migration
• Vmware Enhanced Vmotion (EVC) support
– Version 3.5 update 2
• Better Vmotion and CPU compatibility
Cache
• Vmotion technology allows users to migrate running virtual machines
Control
between compatible physical servers with zero downtime
– Automatically mask to disable features (SSE4.1)
2005 2006 2007 2008 2009 >2010
Rev E Future
Single-Core Rev F “Barcelona “Shanghai” Processors
Dual-Core ”
EVC support for AMD Opteron processors
starts with Rev E for 2 Socket, 4 socket, and 8 socket Servers
19. AMD Smart Fetch Technology
Barcelona Quad-Core
75 35
% %
• Reducing power and
E MH E MH
IDL z IDL z
CORE 0 CORE 1
Clock can be
significantly reduced increase performance
10 1 but has to be ready to
I DL
E
%
MH
z I DL
E
%
MH
z
increase frequency in > Reduces cache probes
the event of a cache
which can increase
CORE 2 CORE 3
request
Shanghai Quad-Core
performance for non-
halted cores
75
%
35
%
> Flushes its L1 & L2
I DL
E
CORE 0
MH
z I DL
E
CORE 1
MH
z
caches (to L3) and
Other cores are
informed that it doesn’t sets a flag so other
10
%
0 have any data.
cores know it doesn’t
have any data that
MH MH
IDL
E z IDL
E z Clock can be
CORE 2 CORE 3
completely turned off
they need
19 Sun Confidential : Sun/Partners Use Only
20. Agenda
• Introduction and Positioning
• Server Architecture
> Sun Fire X2200
> Sun Fire X2100
> Enabling Technologies
• Embedded Light Out Management
• Operating Systems
• System Options
20 Sun Confidential : Sun/Partners Use Only
21. Sun Fire X2100 M2
The 1U Server Compute
●
1-socket 2-way server (Dual Core only)
●
AMD Opteron™ processor Model 1200
●
1U-rackmount
●
Up to 8 GB of memory with 4 DIMM Slots
I/O
●
2 x 8-lane PCI-Express slots (1 x 16-Lane)
●
4 x GigE standard, USB 2.0, Video, Serial ports
● DVD
●
SAS or SATA II Drives
●
Up to 2 TB of storage with 2 x SATA 3.5” disk drives
One of the Most Energy-Efficient Availability
and Highest Performing ●
Hot-pluggable disk
RAID 0 or 1 (Optional)
2-way Server at a Great Price
●
Management
Embedded ILOM Service Processor
Ideal for Web Infrastructure, HPC,
●
●
Remote power on/off/status, GUI+CLI, IPMI 2.0, SNMP
Simulations, Financial Modeling ●
Remote KVM, Floppy/CDROM
Excellent for Life Sciences Operating Environment
● Solaris, Linux, Windows
21 Sun Confidential : Sun/Partners Use Only
22. Sun Fire X2100 M2 System Layout
22 Sun Confidential : Sun/Partners Use Only
23. X2100 Architectural Block Diagram
SATA II AMD Opteron 1200 Rear
Series CPU Panel
Marvell nVidia
4 DDR-2 88E1121
DDR-2 nVidia NIC 1 NIC 0
5.3GB/s PHY
DIMMS
Slots
Marvell
88E1121 nVidia
DDR-2 NIC 1
5.3GB/s nVidia NIC 0 PHY
HT bus (8GB/s) Rear
4 x USB 2.0 USB
Ports
x16 PCIe bus (4GB/s)
Dual x8 PCIe Riser
USB 2.0
or Serial
USB 2.0 Port
Single x16 PCIe Riser Serial
MCP55
DB9
PCI 32bit/33MHz Rear
SATA II 3.0Gb/s VGA VGA
LPC bus Video HD15
SATA II 3.0Gb/s UMP
Port
BIOS SuperIO
2 x USB 2.0 Ultra FLASH Legacy BCM
ATA 133 PROM Device NIC 0
x4 PCIe bus (1GB/s) BCM
Front NIC 1
Panel
3.5”SATA 3.5”SATA Shared
Disk Drive Disk Drive Front Panel Tray Load ELOM NIC
DVD ROM
USB Ports Confidential : Sun/Partners Use Only
23 Sun Port
24. X2100 Architectural Block Diagram
HBA – SATA II or SAS AMD Opteron 1200 Rear
Series CPU Panel
Marvell nVidia
4 DDR-2 88E1121
DDR-2 nVidia NIC 1 NIC 0
5.3GB/s PHY
DIMMS
Slots
Marvell
88E1121 nVidia
DDR-2 NIC 1
5.3GB/s nVidia NIC 0 PHY
Single x16 PCIe Riser Rear
or HT bus (8GB/s)
4 x USB 2.0 USB
Dual x8 PCIe Riser Ports
x16 PCIe bus (4GB/s)
USB 2.0
Serial
USB 2.0 Port
Serial
HBA MCP55
DB9
PCI 32bit/33MHz Rear
SATA II or SAS VGA VGA
LPC bus Video HD15
UMP
Port
SATA II or SAS BIOS SuperIO
2 x USB 2.0 Ultra FLASH Legacy BCM
ATA 133 PROM Device NIC 0
x4 PCIe bus (1GB/s) BCM
NIC 1
Front
3.5”SATA or 3.5”SATA or Panel Shared
SAS Disk Drive SAS Disk Drive Front Panel Tray Load ELOM NIC
DVD ROM
USB Ports Confidential : Sun/Partners Use Only
24 Sun Port
25. Sun Fire X2100 M2 Internals Tour
CPU & 4 x
PCI Fan* Memory Slots PCI Express
*Only 1x Fan for PCI Cooling in Final Design Riser Area
Disk 1
nVidia MCP55
Front
Panel
PCB Serial &
Video ports
CD/DVD
Drive Nvidia NICs
& USB ports
Disk 0
Broadcom
CPU/memory Embedded Lights Out Manager (SP) NICs
25 Blowers Sun Confidential : Sun/Partners Use Only
Power Supply
26. Sun Fire X2100 M2 Motherboard Tour
x16 PCI-Express
Riser Slot
Serial &
Video ports
CPU
Nvidia NICs
& USB ports
4 x DIMM
Sockets
Broadcom
BCM5715 NIC
Embedded
nVidia MCP55 Lights Out
Manager (SP)
26 Sun Confidential : Sun/Partners Use Only
27. Agenda
• Introduction and Positioning
• Server Architecture
> Sun Fire X2200
> Sun Fire X2100
> Enabling Technologies
• Embedded Light Out Management
• Operating Systems
• System Options
27 Sun Confidential : Sun/Partners Use Only
28. Sun Fire X2100 & X2200 M2 Product
Tour
Front Panel System LED
Hot Swappable
Service/Fault Power Button Disks
LED
Locate
Button/LED
Dual USB 2.0 Optional CD/DVD
Ports Drive
28 Sun Confidential : Sun/Partners Use Only
29. Sun Fire X2100 & X2200 M2 Product
Tour Service/Fault Dual nVidia
Dual x8 PCI-Express
Rear Panel LED GbE ports
System Slots
Locate
LED LED or
Power Supply One x16 PCI-Express
(X2100 has no Slot
visible Fan)
Serial DB9 port
Dual
Broadcom
GbE ports
Quad USB 2.0 VGA Video
Ports HD15 port
29 Sun Confidential : Sun/Partners Use Only
30. Sun Fire X2100 & X2200 M2 Product
Serial DB9 port
Tour Rear Ports and Ethernet Port naming
VGA Video
HD15 port
Dual Quad USB 2.0 Dual nVidia
Broadcom Ports GbE ports
GbE ports
0 0 1 Lower left Broadcom port is
shared with the SP via the
1 (SP Net) OS Nvidia Port 0 Nvidia Port 1 BCM5715 UMP port.
OS Solaris RHEL3u8 RHEL4u4 Windows Solaris Nge0 Nge1 Allows the SP to have a
Port 0 BGE0 Eth0 Eth2 NET RHEL3 u8 Eth2 Eth3 separate MAC and IP address
Port 1 BGE1 Eth1 Eth3 NET RHEL4 u4 Eth0 Eth1 and does not affect the main
Windows 2K3 Net Net1 systems use of the port.
30 Sun Confidential : Sun/Partners Use Only
31. Sun Fire X2100/X2200 M2 Components
Tour PCI Express Riser Card
PCI-Express riser card is tooless
Riser is removed from the chassis to insert PCI cards.
A dual x8 PCIe riser is standard with
optional single x16 PCIe
Riser accommodates Low Profile, Half Length cards
Sun Fire X2200 takes 6.5” (160mm) long cards
Cards restricted to 25Watts TOTAL power consumption
31 Sun Confidential : Sun/Partners Use Only
32. Sun Fire X2100 & X2200 M2
Components Tour Power Supplies
Sun Fire X2200 Power Supply Sun Fire X2100 Power Supply
Rated at 450 Watts Rated at 340 Watts
110/220VAC Single Input Auto Ranging/Sensing 110/220VAC Single Input Auto Ranging/Sensing
50/60Hz 50/60Hz
Two Fans Single Fan
No Redundancy No Redundancy
CRU, (Requires a Philips Screwdriver) CRU, Requires a Philips Screwdriver
Uses an adapter bracket to fit System Chassis
32 Sun Confidential : Sun/Partners Use Only
33. Sun Fire X2100 & X2200 M2
Components Tour Disk and Optical Drives
Sun Fire X2100 & X2200 M2 hard Disk Drives Sun Fire X2100 & X2200 M2
3.5” SATA Drives, 250GB, 500GB, 750GB, and 1 TB 7200 rpm DVD Drives
3.5” SAS Drives, 146GB, 300 GB 15,000 rpm DVD ROM (Option X8082A)
3.0Gbps for SATA-II and SAS drives Conventional ATA-133 interface
Hot Plug, Easily installed from the front of the system
System requires Blanks if no drive installed in a slot No Drive in Standard Config
No Disks in Standard Config
33 Sun Confidential : Sun/Partners Use Only
34. Buffered vs. Unbuffered DIMMs
aka. Registered vs. Un-registered
– Registered DIMMs have additional registers placed
between the CPUs and DIMMs
• Improves signal integrity, allowing longer traces and larger,
more reliable memory subsystems
• Up to 4GB per DIMM slot
• 8 DIMM slots per CPU
• Sun Fire X2200 M2 w/AMD Opteron 2000 Series CPU
– Unbuffered DIMMs do not have these registers
• Lower cost and slightly higher performance
• Up to 2GB per DIMM slot, 4 DIMM slots
• Sun Fire X2100 M2 w/AMD Opteron 1200 Series CPU
34 Sun Confidential : Sun/Partners Use Only
35. Single/Dual/Quad Ranked DIMM Limits
X2200 Limitations
• All DIMMS are Ranked, a Rank is a data area created
using some or all of the chips on the DIMM
– All ranks are 64 bits wide(+8 bits of ECC)
– DIMMS can contain one, two or four Ranks
– Each Rank requires a set of control lines
– Column Address Strobe (CAS) particularly
• 8 DIMM/Socket systems don't have sufficient CAS lines
to satisfy QUAD ranked DIMMS in all slots
– Limits us to 4 Quad Ranked DIMMS
– Currently available 4GB DIMMS are all quad ranked
– 4GB DIMMS are dual ranked
• If more than 4 Dual/Quad Ranked DIMMS are populated
per CPU, require clocking of the DDR2 busses are
clocked down from 667 MHz to 533 MHz
35 Sun Confidential : Sun/Partners Use Only
36. Sun Fire X2100/X2200 M2 Components
nVidia MCP55Pro Chipset Features Used
• Highly integrated Single Chip Core Logic
• 1GHz HyperTransport Link x16 up/down
MCP55Pro
> 8GB/s full speed transfer rates
• 6 independent PCI Express Controllers
> Providing 28 PCI-Express Lanes, 20 Used.
• 2 separate SATA-II controllers (1.5/3.0 Gbps)
• ATA-133 controller for CD/DVD devices
• Dual IEEE 802.3 MACs for 10/100/1000BASE-T
• 8 USB 2.0 Ports (2 front/4 rear/2 internal SP)
• PCI 33MHz/32bit bus for embedded Video device
36 Sun Confidential : Sun/Partners Use Only
37. nVidia Chipset Details
PCI Express and PCI legacy
• 16 PCI Express Lanes
> Depending on the Riser configuration used MCP55Pro
> Two x8 PCIe slots (Low profile/Half length)
> One x16 PCIe slot (Low profile/Half length)
• 4 PCI Express Lanes used internally for the
additional Broadcom Dual Port Ethernet Controller
• One PCI 33MHz/32Bit bus dedicated to AST2000
embedded Graphics and Management device
37 Sun Confidential : Sun/Partners Use Only
38. nVidia Chipset Details
nVidia SATA Controllers
• Two independent SATA-II controllers
> One controller is dedicated to each drive MCP55Pro
> Each controller is capable of 1.5 or 3.0Gbps
per direction per channel
> Supports Native Command Queueing
> Supports Tagged Command Queueing
> Supports hot plug (with OS dependencies)
> Support RAID 0 or 1 and JBOD (with OS dependencies)
38 Sun Confidential : Sun/Partners Use Only
39. nVidia SATA Drivers
• Solaris
> Included in Solaris 10 update 3
> Available as a patch for Solaris 10 06/06 MCP55Pro
• Linux
> RHEL3U7 and RHEL4U3 already have nv_sata driver
> More optimized driver provided on the Tools and Drivers CD
> Also available for download from nVidia.com
> SuSE 9 SP3 requires drivers from the Tools and Drivers CD
• Windows 2003 Server
> Default drivers supported
> Drivers provided on the Tools and Drivers CD (also from nVidia)
• VMware ESX 3.x
39 Sun Confidential : Sun/Partners Use Only
40. nVidia Chipset Details
nVidia Network Controllers
• Two independent IEEE 802.3 MACs
• Auto-Negotiation and Duplex settings MCP55Pro
through an external dual port Marvell
88E1121 PHY
• Supports JUMBO frames (up to 9018 bytes)
• 10/100 Mb/s Full or Half Duplex
• 1000 Mb/s Full Duplex only
• Supports NIC Teaming and failover (with OS
dependencies)
40 Sun Confidential : Sun/Partners Use Only
41. nVidia Network Drivers
• Solaris
> Included in Solaris 10 update 3
> Available as a patch for Update 2(06/06) MCP55Pro
• Linux
> RHEL3U7 and RHEL4U3, install from Tools and Drivers CD
> Also available for download from nVidia.com
> SuSE 9 SP3 requires drivers from the Tools and Drivers CD
• Windows 2003 Server
> Drivers provided on the Tools and Drivers CD
> Also available for download from nVidia
• VMware ESX 3.X
> Support from VMware post GA
41 Sun Confidential : Sun/Partners Use Only
42. Agenda
• Introduction and Positioning
• Server Architecture
> Sun Fire X2200
> Sun Fire X2100
> Enabling Technologies
• Embedded Light Out Management
• Operating Systems
• System Options
42 Sun Confidential : Sun/Partners Use Only
43. Embedded LOM Service Processor
ASPEED AST2000
• Provides all Remote USB 2.0
Serial
Administration functionality MCP55
USB 2.0
Serial Port
DB9
> WebGUI PCI 32bit/33MHz Rear
> Remote RKVMS facility LPC bus
UMP
VGA
Video
VGA
HD15
> CLI (DMTF SMASH CLP) BIOS
FLASH
SuperIO
Legacy
Port
> SSH or Serial access to CLI PROM Device
> IPMI 2.0 BCM
x4 PCI-E bus (1GB/s)
> SNMP v1,v2c,v3 NIC 1
Shared SP
NIC port
• Shares access to the systems Serial port, switch using
commands and hot key sequences,
> start /SP/AgentInfo/console and the key sequence 'ESC )'
• Shares access to one of the Broadcom NICs using the UMP port feature of the
BCM5715 Ethernet Controller.
> Has a unique MAC and IP address, different from the OS MAC and IP.
• AST2000 also provides the systems VGA video device using either the AST2000
video driver in Xorg (or the VESA driver), Windows Driver supplied on the Tools and
43
Drivers CD Sun Confidential : Sun/Partners Use Only
44. Embedded LOM Service Processor
UMP Shared NIC
BCM5715C
10/100/1000 MAC
UMP 10/100 MAC
TX Packets
UMP Interface
Gigabit PHY
10/100 MAC
RX
TX
TX
UMP
UMP Command Port
Internet
Processing
BMC BCM
RX
RX
TX
NIC 1
x4 PCIe
RX Packets Shared SP
NIC port
PCIe x4 Interface
• AST2000 shares access to the bottom Broadcom ethernet port
• The BCM5715 UMP Port acts like a dedicated 10/100 MAC
• Providing a Unique MAC and IP address for the UMP port
• BMC connects to this UMP MAC at 100Mbps Full Duplex and can inject BMC ethernet traffic
into the main server ethernet stream.
• BCM5715 filters and passes on traffic from the main ethernet PHY
• Main PHY/MAC can operate at 10/100/1000 and BMC traffic is seamlessly injected
> May Cause issues with critical 'heartbeat' or NIC teaming applications, still in testing
44 Sun Confidential : Sun/Partners Use Only
45. Embedded LOM Service Processor
Initial Setup
• The SP by default 'owns' the serial port
• At system power will see the SP boot
• Once booted, SP presents a CLI login
• Login 'root', default password is 'changeme'
• Issue the 'show /SP/AgentInfo/Network' command to determine
SP IP address (DHCP or static)
> By default SP will attempt to obtain a DHCP lease, if no lease
is granted after 5 seconds, SP will default to 192.168.1.2/24
• Change the IP address using either
> 'set /SP/AgentInfo IpAddress=<new_iP>' for static IP or
> 'set /SP/AgentInfo DhcpConfigured=enable' for DHCP IP
45
• IP changes occur immediately, you may need to reconnect
Sun Confidential : Sun/Partners Use Only
46. Embedded LOM Service Processor
Serial Port Changes
• The SP by default 'owns' the serial port
• On power application to the server, the
SP can be seen booting on the serial line
• Serial port can be configured to show either
the SP CLI or BIOS redirection over serial
• Default is selectable from the SP CLI or through the BIOS setup
> SP CLI can be switched to the BIOS/System serial output by
> 'start /SP/AgentInfo/console'
> Switch back by issuing the key sequence 'ESC' then 'Shift-9'
> Enter the BIOS setup, navigate to the Advanced -> IPMI 2.0
Configuration -> External COM Port screen, change to 'BMC' or
'System'
• NOTE: SP CLI times out after 30 seconds, back to the login prompt
46 Sun Confidential : Sun/Partners Use Only
47. Embedded LOM Service Processor
Web GUI
• Access via HTTP via SP IP address • Provides a simple GUI • Expand buttons to access next
• Auto Redirects over HTTPS • Mini Snapshot of current desktop level of function
• User Authenticates by Local or ADS • Sun Java 1.5+ Browser plugin • Output from function displayed
required in lower frame
• 8 Users/Roles definable
• Simple status screen • Three buttons for
• Requires opening of Firewall Ports
80, 443, 22, 69, for Web GUI and SSH, • Expandable stacked buttons for > System Summary
TFTP (firmware updates) functions > User Control
• RKVMS requires ports 8890, 9000, • Button to Launch RKVMS Java
9001, 9002, 9003 > Setup
WebStart Client
47 Sun Confidential : Sun/Partners Use Only
48. Embedded LOM Service Processor
Web GUI Status Page
• Start the RKVMS with the
Launch button next to the
Snapshot image
• Java WebStart Applet Provides
all RKVMS functions
• Requires Sun Java 1.5+
installed on Client system and
Browser Plugin Installed
48 Sun Confidential : Sun/Partners Use Only
49. Embedded LOM Service Processor
Web GUI RKVMS – System OS booted
• Scalable/Re-sizeable
Graphics window
• Up to 1600x1200
resolution
• Live interaction with
system Desktop
• Mount virtual
DVD/CD/Floppy devices or
ISO images as USB 2.0
local devices
49 Sun Confidential : Sun/Partners Use Only
50. Embedded LOM Service Processor
Web GUI RKVMS - System In BIOS setup
• Remote Installation
• Interact with BIOS
screens
• Issue 'Special' key
sequences (Ctrl-Alt-
Del, etc)
• Secure (encryption
options)
• Quality/bandwidth
options
50 Sun Confidential : Sun/Partners Use Only
51. Embedded LOM Service Processor
DMTF SMASH CLI Examples
Accessible through Serial line or via SSH Username: root
Password: ********
to the SP IP address Sun(TM) Embedded Lights Out Manager
Power on the system with the command
Copyright 2004-2006 Sun Microsystems, Inc.
All rights reserved.
Version 0.90
set /SP/SystemInfo/CtrlInfo PowerCtrl=on
Hostname: SUNSP00C09F000001
Power the system off with the command IP address: 10.6.160.113
MAC address: 00:C0:9F:00:00:01
set /SP/SystemInfo/CtrlInfo PowerCtrl=off /SP ->
/SP -> show
Reset the system with the command /SP
Targets:
AgentInfo
SystemInfo
set /SP/SystemInfo/CtrlInfo PowerCtrl=reset User
TftpUpdate
Rexamine and set the SP IP address.. Properties:
Target Commands:
show /SP/AgentInfo show
cd
set /SP/AgentInfo/ IpAddress=10.6.160.114
/SP ->
set /SP/AgentInfo/ NetMask=255.255.252.0
set /SP/AgentInfo/ Gateway=10.6.163.254
51 Sun Confidential : Sun/Partners Use Only
52. Embedded LOM Service Processor
IPMI 2.0 and SNMP, and CLI PEF
• Accessible one SP has an IP address Username: root
Password: ********
• IPMI 2.0 standard reference Sun(TM) Embedded Lights Out Manager
Copyright 2004-2006 Sun Microsystems, Inc.
All rights reserved.
http://www.intel.com/design/servers/ipmi/
Version 0.90
• IPMI management tool available from Hostname: SUNSP00C09F000001
IP address: 10.6.160.113
http://ipmitool.sourceforge.com MAC address: 00:C0:9F:00:00:01
/SP -> show /SP/AgentInfo/SEL
/usr/sfw/bin/ipmitool
/SP/AgentInfo/SEL
Targets:
• SNMP v1, v2c and v3 supported Properties:
Target Commands:
• Sun Fire X2200 Embedded Lights-Out show
Manager Administration Guide
Information ,2006/06/14 11:17:57
,Processor 0 presence detected
Critical ,2006/06/14 13:52:24 ,CPU1
FAN Tach speed is too low(Value=0.000
http://docs.sun.com Ref. # 819-6588-xx RPM: Threshold=78.400 RPM)
Information ,2006/06/14 13:52:26 ,CPU1
FAN Tach back to normal
Critical ,2006/06/14 13:59:17 ,PCI
FAN0 not present or stop
Information ,2006/06/14 13:59:20 ,PCI
FAN0 back to normal
/SP ->
52 Sun Confidential : Sun/Partners Use Only
53. Embedded LOM Service Processor
Hints and Tips...
Firmware is changing rapidly, make sure SUNSP0016365B982B login: root
Password:
you have the latest version before logging login[425]: root login on `ttyS1'
bugs. Sun(TM) Embedded Lights Out Manager
Copyright 2004-2006 Sun Microsystems,
To recover a lost Embedded LOM Inc. All rights reserved.
Version 1.1
Password. Hostname: SUNSP0016365B982B
> Access the system locally with a screen and keyboard IP address: 10.6.160.115
MAC address: 00:16:36:5B:98:2B
> BIOS Setup -> Advanced -> IPMI 2.0 Configuration -> Reset BMC Root
password System serial number: 0624QC0017
/SP -> show
My local mouse is not sync'd with the /SP
remote mouse on the Remote Console
Targets:
AgentInfo
SystemInfo
window User
TftpUpdate
> Issue the command xset m 1 1 Properties:
Target Commands:
> In the remote system desktop show
cd
> Use the Ctrl-Alt-M key press to initialize the remote mouse to the top left reset
of the screen. /SP ->
53 Sun Confidential : Sun/Partners Use Only
54. Agenda
• Introduction and Positioning
• Server Architecture
> Sun Fire X2200
> Sun Fire X2100
> Enabling Technologies
• Embedded Light Out Management
• Operating Systems
• System Options
54 Sun Confidential : Sun/Partners Use Only
55. Operating Systems
• SuSE SLES 9 SP3 • Windows 2003 Server
> 64bit supported > 32 and 64bit
> Default installs from media > Installs from media
> Tools and Drivers CD > Tools and Drivers CD
updates Video, SATA,
Broadcom and nVidia NIC updates Video, SATA
drivers and NIC drivers
• VMware 3.5
> Taurus Support ONLY
55 Sun Confidential : Sun/Partners Use Only
56. Sun Fire Operating Systems
Operating System Dates/Comments
Solaris x64 10u2 and up 64-bit
Red Hat Enterprise Linux 3, U8 32-bit, 64-bit
Red Hat Enterprise Linux 4, U4 32-bit, 64-bit
Red Hat Enterprise Linux 5 32-bit, 64-bit
SUSE Linux Enterprise Server 9, SP3 (SLES 9) 64-bit
SUSE Linux Enterprise Server 10 (SLES 10) 64-bit
Windows Server 2003, Enterprise and Standard Editions, SP1 32-bit, 64-bit
Windows Server 2008, Datacenter, Enterprise and Standard Editions
32-bit, 64-bit
VMware ESX 3.0.2 (Sun Fire X2200 M2 Dual Core only) 64-bit
56 Sun Confidential : Sun/Partners Use Only
57. Sun Fire Operating Systems
Quad-Core
Operating System Dates/Comments
Solaris x64 10u5 64-bit
Red Hat Enterprise Linux 4 U5 32-bit, 64-bit
Red Hat Enterprise Linux 5 U1 32-bit, 64-bit
SUSE Linux Enterprise Server 9, SP4 (SLES 9) 64-bit
SUSE Linux Enterprise Server 10, SP1 (SLES 10) 64-bit
Windows Server 2003, Enterprise and Standard Editions, SP1 32-bit, 64-bit
Windows Server 2008, Datacenter, Enterprise and Standard Editions 32-bit, 64-bit
VMware ESX 3.0.2 or ESX 3.5 U1 (Sun Fire X2200 M2 Quad Core only) 64-bit
57 Sun Confidential : Sun/Partners Use Only
58. Agenda
• Introduction and Positioning
• Server Architecture
> Sun Fire X2200
> Sun Fire X2100
> Enabling Technologies
• Embedded Light Out Management
• Operating Systems
• System Options
58 Sun Confidential : Sun/Partners Use Only
59. Standard Configurations
Sun Fire X2200
Base Config A85-A-Z
1RU Chassis
No AMD Opteron CPU (2 x 1207-pin L1 Sockets)
4 x 10/100/1000 Base-T Ethernet Ports
Integrated 2D Graphics Controller (AST2000/VESA)
AST2000 Integrated Service Processor, IPMI2.0, WebGUI, CLI, SNMP
No Disk Drive
No DVD
No PCI Riser Card
Entry Config A85-JWZ1-H-2GB-JL8
Base Config A85-A-Z plus....
1 x AMD Opteron 2210 (1.8GHz, Dual Core ,95 Watts)
2 x 1GB DIMMS (Registered, ECC DDR2-667)
I/O Riser Card with 2 x 8-Lane PCI-Express slots
Mid Config A85-JFZ2-H-4GB-JL8
Base Config A85-A-Z plus....
2 x AMD Opteron 2214 (2.2GHz, Dual Core ,95 Watts)
4 x 1GB DIMMS (Registered, ECC DDR2-667)
I/O Riser Card with 2 x 8-Lane PCI-Express slots
Performance Config A85-JGZ2-H-8GB-JL8
Base Config A85-A-Z plus....
59 Sun Confidential : Sun/Partners Use Only
60. Standard Configurations
Sun Fire X2100
Part Number Description
A84-GQZ1-H-4GB-JL8 Sun Fire X2100 M2 x64 Server: AMD Opteron Model 1222 dual core processor
(3.0GHz/1MB), 4x 1GB unregistered ECC DDR2-667 memory, no Serials ATA
drives, no DVD, 1x PSU, Service Processor, 2x 10/100/1000 Ethernet ports, 6x
USB 2.0 ports, 1x I/O riser card with 2x PCI-Express x8 slots, no power cords,
order Geo-specific x-option. RoHS-5. Standard Configuration
A84-GPZ1-H-2GB-JL8 Sun Fire X2100 M2 x64 Server: AMD Opteron Model 1220 dual core processor
(2.8GHz/1MB), 2x 1GB unregistered ECC DDR2-667 memory, no Serials ATA
drives, no DVD, 1x PSU, Service Processor, 2x 10/100/1000 Ethernet ports, 6x
USB 2.0 ports, 1x I/O riser card with 2x PCI-Express x8 slots, no power cords,
order Geo-specific x-option. RoHS-5. Standard Configuration.
A84-GGZ1-H-4GB-JL8 Sun Fire X2100 M2 x64 Server: AMD Opteron Model 1218 dual core processor
(2.6GHz/1MB), 4x 1GB unregistered ECC DDR2-667 memory, no Serials ATA
drives, no DVD, 1x PSU, Service Processor, 2x 10/100/1000 Ethernet ports, 6x
USB 2.0 ports, 1x I/O riser card with 2x PCI-Express x8 slots, no power cords,
order Geo-specific x-option. RoHS-5. Standard Configuration.
60 Sun Confidential : Sun/Partners Use Only
61. Standard Configurations
Sun Fire X2200 - Dual-Core
Part Number Description
High Performance Dual Core Sun Fire X2200 M2 x64 Server: 2x AMD Opteron Model 2218 dual
core processor (2.6GHz/1MB/95W), 4x 2GB registered ECC DDR2-
A85-JGZ2-H-8GC-JL8 667 memory, No HDD, No DVD-ROM, 1x PSU, Service Processor,
4x 10/100/1000 Ethernet ports, 6x USB 2.0 ports, 1x I/O riser card
with 2x PCI-Express x8 slots, no power cords, order Geo-specific
x-option. RoHS-5. Standard Configuration.
61 Sun Confidential : Sun/Partners Use Only
62. Standard Configurations
Sun Fire X2200 – Quad-Core Barcelona
Part Number Description
A85-FSZ1-H-4GC-JL8 Sun Fire X2200 M2 x64 Server: 1x AMD Opteron Quad Core Model
2356 quad core processor (2.3 GHz, 2MB L3 cache, 75W ACP), 2x
2GB registered ECC DDR2-667 memory, no drives, 1x PSU,
Service Processor, 4x 10/100/1000 Ethernet ports, 6x USB 2.0
ports, 1x I/O riser card with 2x PCI-Express x8 slots, no power
cords, order Geo-specific x-option. RoHS-5. Standard
Configuration.
A85-FFZ1-H-4GC-JL8 Sun Fire X2200 M2 x64 Server: 1x AMD Opteron Quad Core Model
2354 processor (2.2 GHz, 2MB cache, 75 W ACP), 2x 2GB
registered ECC DDR2-667 memory, no drives, 1x PSU, Service
Processor, 4x 10/100/1000 Ethernet ports, 6x USB 2.0 ports, 1x I/O
riser card with 2x PCI-Express x8 slots, no power cords, order
Geo-specific x-option. RoHS-5. Standard
Quad Core HE Config Sun Fire X2200 M2 x64 Server: 2x AMD Opteron Quad Core Model
A85-SUZ2-H-8GC-JL8 2347HE processor (1.9 GHz, 2MB cache, 55 W ACP), 4x 2GB
registered ECC DDR2-667 memory, no drives, 1x PSU, Service
Processor, 4x 10/100/1000 Ethernet ports, 6x USB 2.0 ports, 1x I/O
riser card with 2x PCI-Express x8 slots, no power cords, order
Geo-specific x-option. RoHS-5. Standard
62 Sun Confidential : Sun/Partners Use Only
63. Sun Fire X2200 Standard Configurations
• 800MHz DIMMs being analyzed
• EOL – 1GB memory support
• More ATO and less standard configurations
• Sun Fire X2100 will not support Shangahi
CPU Clock Speed DDR2 Memory Memory # of SAS HDD RAID HBA DVD-RW PSUs Part Number
Sun Fire X2200 Shanghai Standard Configurations
2x 2376 2.3GHz 4x 2GB -667 SR 8GB No HDD No No 1 A85-ZSZ2-H-8GC-JL8
2x 2384 2.7GHz 4x 2GB -667 SR 8GB No HDD No No 1 A85-ZWZ2-H-8GC-JL8
63 Sun Confidential : Sun/Partners Use Only
64. Sun Fire X2200 Upgrade to Shanghai
• http://docs.sun.com/source/820-3270-12/index.html
• Download the Sun Fire X2200 M2 Server Tools and Drivers CD v2.0 (or
later) ISO image
• Record Current BIOS settings (ELOM)
• Upgrade processor to Shanghai
• Is BIOS 3D08?
> Then Upgrade 512K BIOS PROM to 1M
> Remove the Firmware PROM and install new PROM
> Special PLCC extraction tool is necessary
• Upgrade the SP/BMC Firmware with Tools and Driver CD
• Check BIOS and upgrade if necessary
• Micron memory being phased out – field notice
Upgrade Options
CPU X-Option ATO Date
AMD Opteron 2376 (2.3GHz/512KB, 75W ACP Quad Core) X5334A 5334A Dec-2008
AMD Opteron 2384 (2.7GHz/512KB, 75W ACP Quad Core) X5335A 5335A Dec-2008
New 4GB Memory X-Option ATO Date
8GB DDR2-667 Registered ECC Memory (2x4GB) X4087A 4087A Dec-2008
64 Sun Confidential : Sun/Partners Use Only
65. Add-in Card Options
X-Option ATO CRS Description
SG-XPCIE2FC-QF4 SG-PCIE2FC-QF4 SG-PCIE2FC-QF4 Sun StorEdge 4 GB Dual Port Fibre Channel PCI-Express Card (Qlogic). RoHS-6.
SG-XPCIE1FC-QF4 SG-PCIE1FC-QF4 SG-PCIE1FC-QF4 Sun StorEdge 4 GB Single Port Fibre Channel PCI-Express Card (Qlogic). RoHS-6.
SG-XPCIE2FC-EM4 SG-PCIE2FC-EM4 SG-PCIE2FC-EM4 Sun StorEdge 4 GB Dual Port Fibre Channel PCI-Express Card (Emulex). RoHS-6.
SG-XPCIE1FC-EM4 SG-PCIE1FC-EM4 SG-PCIE1FC-EM4 Sun StorEdge 4 GB Single Port Fibre Channel PCI-Express Card (Emulex). RoHS-6.
X7280A-2 7280A-2 7280A-2 Sun PCI-E Low profile Dual GigE (Copper) UTP, low profile bracket on board.
Standard bracket included in X-option. ROHS-6.
SG-XPCIE2SCSIU320Z SG-PCIE2SCSIU320Z SG-PCIE2SCSIU320Z Sun PCI-E Ultra320 SCSI 2-port HBA. RoHS-6
7281A-2 7281A-2 Sun PCI-E Low-Profile Dual GigE (Fiber) MMF, low profile bracket on board. Standard
X7281A-2 bracket included in X-option. RoHS-6.
X1106A-Z n/a X1106A-Z Single port Sun 10 Gigabit Ethernet Networking Card with fixed transceiver (Intel)
X1107A-Z n/a X1107A-Z Dual port Sun 10 Gigabit Ethernet Networking Card with fixed transceiver (Intel)
X1236A-Z 1236A-Z 1236A-Z Infiniband PCI-Express Card. RoHS-6.
SG-XPCIE4SAS3-Z SG-PCIE4SAS3-Z SG-PCIE4SAS3-Z LSI Logic SAS3041E-R, PCI Express, 4-port 3Gb/s (SAS) HBA
List subject to change and not final
65 Sun Confidential : Sun/Partners Use Only