Digital Identity is Under Attack: FIDO Paris Seminar.pptx
Sun storage tek 6140 technical presentation
1. Sun StorageTek™ 6140 Array
Technical Presentation
Presenter
Title
Sun Microsystems, Inc.
2. Your business is really taking off -
your data is growing even faster
You need greater...
• Protection – you have more to lose
• Performance - meeting new
application demands
• Availability – more people need
access more often
• Scalability – growth continues...
• Flexibility – multi-purpose solutions
and options that save money
• Manageability – simple, powerful,
intuitive, and low-cost
Sun Confidential: Internal Only
3. Sun StorageTek™ Modular Arrays
and Systems
Value — get the most for your
money
• Cost-effective balance of
performance, availability, and
scalability
• High-end features previously only
available on expensive, high-end
systems
• Affordable application and storage
consolidation
Sun Confidential: Internal Only
4. Sun StorageTek™ Modular Arrays
and Systems
Flexibility — easily keep up
with ever-evolving applications
• Non-disruptively adapt to
changing application
requirements
• Data-in-place upgrade-ability
across the line and across
generations
• Family compatibility preserves
your investment
Sun Confidential: Internal Only
5. Sun StorageTek™ Modular Line of
Arrays and Systems
Data protection
• Highly-available system design
• Broad suite of data protection
software
• World-class 24/7 service and
support
Sun Confidential: Internal Only
6. Sun StorageTek™ Modular Line
Sun StorageTek™
6540 array
Ideal for
database-driven
applications
Leader in
price/performance
Enterprise-class
data protection Excels in HPTC
on a budget environments
Multi-tiered storage
Replication
Sun StorageTek™ target
6140 array
Sun Confidential: Internal Only
7. What's new with the Sun StorageTek™
6140 Array?
• RoHS-compliant
• Feature enhancements over earlier products:
✔ Up to 8 FC Host ports
✔ Up to 4GB cache
✔ Faster Performance
• Two model options based on
✔ Host ports, cache size, performance, scalability
and data services options. Hot new 4
Gb/s array
• End-to-end 4Gb/second data paths at the entry
• Switched Loop Architecture to the midr
ange!
• About 2X the Performance of StorEdge 6130 or STK
FLX240
• $20K Entry point at US List Price
✔ Includes dual RAID controllers, 2 GB cache, 4
FC host ports, 5 drives, Common Array
Manager software, 4 gigabits per-second
Sun Confidential: Internal Only
8. Sun StorageTek 6140 Array
Compared to Previous Generation
StorageTek 6140 StorageTek 6140 StorEdge 6130/ Flexline 240
with 4GB cache with 2GB cache Flexline 240 Drive Limited
End-to-Eng 4Gb/s infrastructure YES YES NO NO
Cache Size (per array) 4GB 2GB 2GB 2GB
Max capacity per array 56TB 32TB 43TB 4.2TB
Host Ports 8 4 4 4
Host Connectivity 4 or 2 or 1 Gbit FC 4 or 2 or 1 Gbit FC 2 or 1 Gbit FC 2 or 1 Gbit FC
# of drives per tray Min 5 / Max 16 Min 5 / Max 16 Min 5(3 for 240) / Max 14 Min 3 / Max 14
Max # of drives per array 112 64 112 14
Disk Type FC/SATA FC/SATA FC+SATA FC Only
FC/SATA Intermix YES YES NO NO
SBOD YES YES YES NO
RoHS Compliant YES YES NO NO
Cache:125K IOPs, 1500 MB/s Cache:100K IOPs, 1200 MB/s Cache:77.5K IOPs, 800 MB/s Cache:77.5K IOPs, 800 MB/s
Performance
Disk: 44k IOPs, 990 MB/s Disk: 30k IOPs, 700 MB/s Disk: 25k IOPs, 400 MB/s Disk: 25k IOPs, 400 MB/s
Storage Domains (partitions) 4/8/16/64 4/8/16 16/64 4/16
SnapShot, Volume Copy, SnapShot, Volume Copy, SnapShot, Volume Copy,
Data Services Snap Shot
Data Replication Data Replication Data Replication
Management (Included) Common Array Manager Common Array Manager Common Array Manager / N/A N/A
StorageTek 6140 Array Previous Generation
Sun Confidential: Internal Only
9. High-quality, High-availability
• 100% redundant I/O paths with auto-
failover helps ensure against any
application disruption
● Non-disruptive controller firmware
upgrades
• Switched “SBOD” architecture enables
pin-point control over back-end
operations
• Battery-backed cache provides data
protection in the event of power failure
• Chip-level RAID parity calculations help
ensure continuous reliability of high
performance RAID operations
9
10. Flexibility
• Fibre Channel and SATA
Intermix
• Hot-swappable components OLTP Data
Applications Warehouse
> Disk Drives Applications
> Batteries
> Controllers FC FC SATA SATA
• Grow seamlessly as your
business grows
Point-in-Time Copy
10
11. Flexibility
• Non-disruptive changes
> Dynamic Capacity Expansion enables capacity to be easily
added to existing volume groups.
> Dynamic Volume Expansion enables capacity to be easily
added to existing Volumes/LUNs*
> Dynamic Virtual Disk Expansion enables raw capacity to be
added to existing V-disks
> Dynamic RAID-level and Segment-size Migration allow for
changing application workloads
* OS-dependent 11
12. What's Hot About 4 Gb/s?
• Faster access
> Reduces time to load large data sets by up to half
• Faster back-ups
> Faster data transfers
> Move data between tiers in less time
> Faster mirroring and remote replication
• Faster restores
> Restores data twice as fast
• Sun StorageTek array is end-to-end
> Maximizes 2 and 4 Gb/s
Sun Confidential: Internal Only
13. Targeted Performance - Estimates
Sun StorageTek 6140 Array Sun StorageTek 6140 Array
2 GB Cache 4 GB Cache
Cached Read IOPs 100,000 125,000
Disk Read IOPs 30,000 44,000
Disk Write IOPs 6,000 9,000
Cached Read MB/sec 1,200 1,500
Disk Read MB/sec 700 990
Disk Write MB/sec 650 850
Sun Confidential: Internal Only
15. Sun StorageTek™ Data Replicator
Software
● Synchronous replication
● Asynchronous replication
● Write-order consistency groups
WAN
Consistency Group Consistency Group
Async. Log Snap Pool Snap Pool
Vol A Vol B Vol C Vol A Vol B Vol C
15
16. Sun StorageTek™ Data Replicator
Highlights
• Support for synchronous & asynchronous writes
> Write order consistency option for asynchronous mirror
• Support for dynamic mode switching
> Go back and forth between synchronous and
asynchronous modes without breaking mirror
• Fast resynchronization of broken/suspended mirror
• Access the remote volume while mirror is active
> Snap/Copy the mirror while replicating
• Support for multiple mirror relationships
> 32 per STK6140 storage subsystem
Sun Confidential: Internal Only
17. Robust Data Protection
Sun StorageTek™ Data Snapshot Software
LUN1 – Sales
LUN2 – Sales BU
• Creates point-in-time
image of a volume
E
> Up to four snaps per volume ABC
A' B C'
• Requires less disk space Base Snapshot
Volume Volume
• Ideal for backup, restore, Sales Sales BU
checkpoint AC
Snapshot
Repository
Physical Logical
17
18. Ideal for Tiered Data Storage
Strategies
Application
• Near-line data backup
• OLTP, data warehouse, 500 GB SATA II
e-commerce
• Content management
OLTP Data
• Email, vmail Applications Warehouse
Applications
• Computer generated
animation (CGA)
• Service providers FC FC SATA SATA
• Medical imaging, data acquisition
Snapshot 18
19. Duplicating Data
Sun StorageTek™ Volume Copy Software
Production Analysis
• Completely replicates Server Server
volumes
– Up to 8 concurrent active
copies per source volume
• Ideal for analysis, testing, ABC ABC
mining, enhanced backup
Source Data
• Migrate data Volume
Orders
Clone
Orders
between tiers
19
20. Storage Domains
Simplifying Management with Storage Partitions
Host Host Host
A B Group C
• Match applications to
storage class
• Lower TCO by Storage Storage Storage
consolidating storage for Partition
A
Partition
B
Partition
C
heterogeneous hosts LUN
0
LUN
0
LUN
0
LUN
1
• Workloads co-exist LUN LUN LUN
harmoniously, with
1 2 3
minimal sharing LUN
2
Unmapped Volumes
20
22. Multi-dimensional Investment Protection
• Use the same software across the family and
easily upgrade from previous generations – no need
to re-train staff
• Migrate seamlessly and painlessly
> replicate data from old array to new array with the
array's data migration software
> Data-in-place upgrades allow users to move disk
and controller trays to new systems without
disrupting data
• HotScale allows FC &/or SATA drive enclosures to
be non-disruptively added to existing systems.
• Instant Availability means new disks are accessible
as soon as they are added to the system.
• Backward Compatibility easily incorporate existing
StorEdge™ 6130 or FlexLine™ modules into new
systems
Sun Confidential: Internal Only
23. Sun StorageTek™ Common
Array Manager
Centralized Management Utility
● Easily manage many 6140 arrays Save Time
● Deploy by application type (Storage Profiles) Use Storage Profiles to quickly and
● Up to 1024 volumes predictably provision storage to
● RAID 0, 1+0, 1, 3, 5 precise application demands.
● Dynamic expansion
● Dynamic re-configuration
Maximize Performance
Easily and dynamically tune any
attribute to exact application
tolerances.
Grow Without Disruption
Dynamically scale the volume as the
application needs dictate.
23
24. Sun StorageTek Common Array
Manager
Performance Tracking Utility
Controller, volume and array statistics
Optimize System Performance
●
● Track IOPS performance
Quickly visualize performance health, ● Track throughput (MB/s) performance
finely tune attributes to reach the optimal ● Track IO characteristics
configuration for precise application ● Track write %, read %, cache hit %
needs.
Reduce System Downtime
Performance degradation is often
a precursor to component or system downtime,
performance tracking enables predictive,
preemptive maintenance.
24
25. Sun StorageTek Common Array
Manager
Optimize System Operations
Easily ensure the system is running with the latest
patches. Link to Sun Download Center to easily
download, install, and
track patches as needed.
Maximize System Uptime Automated Diagnostics
Wherever you are in the world, quickly receive ● Set and track system alerts
notification of any system health issue...quickly ● Easily manage patch distribution
isolate and repair failed components. ● Embedded service diagnostics
25
26. Sun StorageTek Common Array
Manager
Simplify System Management
With administrative domains, manage storage
by application or targeted host/organizations.
Storage Domains
● Segment storage by host/app. Ensure Optimum Performance
● Up to 64 “virtual” arrays
Use Storage Domains to unite key storage
● Heterogeneous host support
resources with critical business applications.
● Multiple storage classes
26
27. What's HOT about this new array?
• FASTER... applications, backup and restore,
archive, and data retrieval
• Sun StorageTek™ Common Array Manager,
application-oriented management across the
StorageTek 6000 Family
• Data protection - synchronous and
asynchronous replication, snapshots with
copy-on-write; full-volume copy Sun StorageTek™ 6140 array
• Backwards and forwards compatibility -auto-
negotiating fibre channel interfaces support
new and existing gear
• Tiered storage in a single system with
intermixing of up to 112 Fibre Channel or
Serial ATA drives
• Maximized data center real estate with 16
disk drives per tray
• Optional SANtricity software Sun Confidential: Internal Only
28. Two Great Flavors
• 6140 with 2 GB Cache • 6140 with 4 GB Cache
> $20K entry price > $40K entry price
> 4 x 4Gb host/SAN port > 8 x 4Gb host/SAN port
> 2 GB cache > 4 GB cache
> Up to 3 expansion trays > Up to 6 expansion trays
> Up to 64 drives > Up to 112 drives
> 100K IOPS > 120K IOPS
Sun Confidential: Internal Only
29. Sun StorageTek 6140 Array – 2 Versions
Sun StorageTek 6140 Array 4 GB Cache 2 GB Cache
Host channels 8 4
Native host interface link speed 4 Gb/s 4 Gb/s
Supported host interface link speeds 4, 2, 1 Gb/s 4, 2, 1 Gb/s
Total host channel bandwidth 3,200 MB/s 1,600 MB/s
Redundant drive channels Four 4 Gb/s Four 4 Gb/s
Total drive channel bandwidth 1,600 MB/s 1,600 MB/s
Max drives 112 64
Drives supported FC and SATA FC and SATA
Processor Intel xScale 667 Intel xScale 667
XOR engine Integrated Integrated
Data cache per dual-controller system 4 GB 2 GB
Sun Confidential: Internal Only
30. Sun StorageTek 6140 Array – Rear View
Drive Interfaces Ethernet Host Interfaces Battery
Power/Cooling Serial Port Controllers
Sun Confidential: Internal Only
32. Controller Faceplate -6140 4GB cache
Serial Port 4Gb/s Host Ports
Battery (CRU)
Dual
Expansion Ports Dual Ethernet Ports
LEDS, Tray Identifier
Sun Confidential: Internal Only
33. Supported Disk Drives
• 10 K RPM FC drives
> 2 Gb/s interface
> 146 GB, 300 GB
• 15 K RPM FC Drives
> 4 Gb/s interface
> 73 GB, 146 GB
• SATA-II drives
> 500 GB capacity
> Native Command Queuing
> 3 Gb interface
Sun Confidential: Internal Only
34. Cache/Battery Notes
• Cache memory is shared between system memory and
cache memory
• All data cache is mirrored for controller failover
• Available cache = (total cache – system memory)/2
• With 2 Gb cache/controller: (2 GB – 160 MB) / 2 = 944 MB
• Write back cache changes to write through mode when a
battery is removed or failed
• Power Cooling Unit failure does not cause cache mode
change
• Controller Failover causes cache to go into write through
mode
• Data is stored in cache of 72 hours @2 GB, > 72 hours @ 1
GB
• Data in cache from a power failure is de-staged when
power is returned
Sun Confidential: Internal Only
36. Sun StorageTek 6140 Array - Controllers
• Two models:
> – four host ports per controller
> – two host ports per controller
• Uses 667MHz Xscale processor
with embedded XOR engine
• 1 DIMM memory slot
> – 2 GB per controller
> – 1 GB per controller
• Two 4 Gb/s FC external
drive interfaces per controller
Sun Confidential: Internal Only
37. RAID Controller - Sun StorageTek 6140
Array with 4 GB Cache, 8 Host Ports
LSI 3994 Controller
Sun Confidential: Internal Only
38. RAID Controller - Sun StorageTek 6140
Array with 2 GB Cache, 4 Host Ports
LSI 3992 Controller
Sun Confidential: Internal Only
39. Controller Hardware Features
• Dual controller architecture/
• 667 MHz Lindsay XScale IOP80331
> DDR-I 333 MHz DIMM up to 2GB.
> PCI-X 133/100 MHz, I2C selectable upon reset (sub-model defined).
> UART
> 2x I2C Cores
• Up to 4 FC Host Ports, 2/4 Gbps (auto-negotiated) using Agilent
DX4+
• Switched Architecture Disk Connections using Vixel SOC422
• Dual Disk Expansion Ports
• Dual 10/100BASE-T Ethernet Ports/w EEPROM (91C111)
• Optional Battery Backup with removable CRU
• 128 kB NVSRAM, Dallas DS1556
Sun Confidential: Internal Only
40. Software Architecture
> Same architecture as 6130 Customer Browser
❏ Supports 6130 and 6140 SMI/S Mgmt S/w
❏ Customers can upgrade a 6130
management station and it will Customer Management Station Customer Data
Host
support both products Web Server
Apache / Tomcat
Remote
CLI
> Software Components Management Diagnostics
Diagnostics
UI & Logic
StorADE
❏ Sun StorageTek Common Array
UI & Logic UI & Logic
Element Manager StorADE
Multi-pathing
Manager (CAM) BOL Driver
MPXIO
Telemetry
to Sun
❏ Diagnostics - StorADE 2.4
Fibre Channel
Driver
Storage Software CIMOM
❏ SSCS – command line interface Manager
(CLI)
❏ Storage Software Manager
Array API
Array
Provider
❏ CSM-2 Firmware Ethernet Management Network
Fibre Channel Data Network
CSM2
> SANtricity Option
RAID
Controller
Sun Confidential: Internal Only
41. Array Management Software
● Sun StorageTek Common Array Manager (CBEM)
– Can manage 6130 and 6140 from one instance
– Support for Remote Replication
– Support for Vdisk / Drive Revive
– Navigational Tree added for ease of use
– Volume Mapping Summary
– Activity Log
• SANtricity - Optional
Sun Confidential: Internal Only
42. Management Host Compatibility
• Sun StorageTek Common Array Manager (CAM)
> Solaris SPARC
> 8 Update 4
>9
> 10
> Solaris x86, Windows
> Linux – both Suse and RedHat coming soon....
• SANtricity
> Solaris, Windows, Linux, AIX, HP-UX
Sun Confidential: Internal Only
43. Storage Software Manager
● Replaces Software Lifecycle Manager from SE6130
● InstallShield based installer
● Available with both Command Line and Graphical
User Interfaces
● Installs and/or Upgrades
– Data Host/Management Host Software
– Array Controller F/W
– Array Expansion Tray Firmware
– Disk Drive Firmware
Sun Confidential: Internal Only
44. Serial Port Service Interface
• Mini-DIN connector
> Mini-DIN to 9 pin D serial convertor included
• Uses
> Set TCP/IP network parameters
> If DHCP and static IP configuration are not appropriate
> Display network parameters
> Reset array password
Sun Confidential: Internal Only
45. Service Interface Example
Send <BREAK> for Service Interface or baud rate
change
Press within 5 seconds: <S> for Service Interface,
<BREAK> for baud rate
Current date: 01/27/06 time: 18:43:01
Enter Password to access Service Interface (60 sec
timeout):
Service Interface Main Menu
==============================
1) Display IP Configuration
2) Change IP Configuration
3) Reset Storage Array (SYMbol) Password
Q) Quit Menu
Enter Selection:
Sun Confidential: Internal Only
46. Interop
• Interop matrix is based upon Sun internal plus OEM
(Engenio) testing results.
> Solaris/SPARC – versions: Solaris 8 Update 4, Solaris 9, Solaris 10. Failover
driver MPxIO
> Solaris x64 – versions: Solaris 10 update 1. Fail-over drive MPxIO.
> Microsoft Windows – 2000, 2003
> IBM AIX
> HP HPUX
> Red Hat Linux RHEL –
> (Novell) SuSE Linux SLES
> Novell Netware
> SGI IRIX
Sun Confidential: Internal Only
47. Sun StorageTek 6140 Array
Data Services
● Data Services are premium features. Licensing key
for purchase.
● Hard Licensing is used. Licenses are keyed to the
array serial number.
● Snapshot
● Volume Copy
● Remote Replication
● Storage Domains (0 default, 4,8,16, 64 optional)
Sun Confidential: Internal Only
48. StorageTek Data Replicator
• Storage-based solution
• Fibre-channel
• Consumes one FC port per controller
• Synchronous & asynchronous write mode
– Asynchronous write-order consistency
– Dynamic write mode switching
• Adjustable replication I/O priority
• Fully integrated with StorageTek Common Array
Manager
– Wizard based setup
• DRM will be supported using SMIS 1.1 provider
Sun Confidential: Internal Only
49. StorageTek Data Snapshot
• Allows creation of a virtual “Point In Time” (PIT) copy of a
volume in the storage array
> Fairly instantaneous
> Requires less space than a full copy
> Mappable to any host
> Can be read from and written to
> Copied volume termed the “base” volume
> Data required to preserve the snapshot contained in
“reserve” volume
Sun Confidential: Internal Only
50. Snapshot Reserve Volume
• Holds data overwritten in base, or data written to snapshot
volume
> Data preserved from base termed COW (copy-on-first-
write) data.
• Can reside in different virtual disk from base volume
• User defined capacity – defaults to 20% of base
• Expandable via DVE
• One reserve per snapshot (no shared copy-on-write data)
Sun Confidential: Internal Only
51. Data Snapshot Limits
• Upto 4 snapshots of a given volume
• Max 512 snapshots per StorageTek 6140 array
• Base volume, reserve volume and snapshot are all
owned by the same controller
Sun Confidential: Internal Only
52. StorageTek Data Volume Copy
• Allows creation of a complete byte-for-byte copy of a
volume within the storage array
> Copied volume termed “source” volume
> Copy of volume termed “target” or “clone” volume
• “Copy Request” Object
> Associates source and target volumes (copy pair)
> May be created, started, stopped and deleted
Sun Confidential: Internal Only
53. Volume Copy – Source Volume
• May be a standard volume, snapshot or replication primary
volume
• Source volume is read-only during copy process
> While volume copy has status of In Progress, Pending or
Failed
> Maintains PiT integrity
> Volcopy a snapshot to maintain normal I/O to source
volume during copy
• If you need to continue to write to the source
volume, create a snapshot, then create volume
copy of the snapshot
Sun Confidential: Internal Only
54. StorageTek Volume Copy –
Target Volume
• Selection
> May be a standard volume, base volume of a disabled or
failed snapshot, replication primary
> May reside in a different vdisk to the source volume
> Must be at least the same capacity as the source volume
• Identical to the source volume after the copy
completes
• As long as copy relationship is maintained
> Target copy can be set to read-only
> “Re-copy” command uses same source/target
Sun Confidential: Internal Only
55. Remote Volume Replication
• Storage-based solution
• Fibre-channel
• Consumes one FC port per controller
• Synchronous & asynchronous write mode
– Asynchronous write order consistency
– Dynamic write mode switching
• Adjustable replication I/O priority
• Fully integrated with StorEdge Configuration Service
– Wizard based setup
• DRM will be supported using SMIS 1.1 provider
Sun Confidential: Internal Only
56. Replication Rules
● Mirroring relationship is on a volume basis
● At most one replication relationship per volume
● Primary and secondary volumes must be standard
volumes
● An array may have up to 32 replication relationships
(primary or secondary)
● A minimum of 2 arrays are required
● Both primary and secondary volumes must be
owned by the same controller in each storage array
● Secondary volumes are read-only
Sun Confidential: Internal Only
57. StorageTek 6140 Array - Technical
Summary
– New 4 gigabits-per-second
improves time to data access and is
backward and forward compatible
– Same high-availability hardware as
in previous generations
– Same open SMI/S management
software as in previous generations
– Same enterprise-level replication,
snapshot, and volume copy
– Common management software
across the StrorageTek 6000 family
– Data-in-place upgradeability
preserves investment
Sun Confidential: Internal Only
58. Sun StorageTek 6140 Array
Technical Presentation
Presenter
presenter@sun.com