SlideShare une entreprise Scribd logo
1  sur  12
SHREDDING AND STERILIZATION
                                                                                                                                                                          OF MEDICAL WASTE
                                                ECODAS
                                                A Global Presence
Advantages:                                     ECODAS process can be used by various healthcare facilities or their
                                                medical waste treatment service providers.
                                                We are the leader in providing an alternative medical waste treatment
    Easy to use:                                technology in many countries around the world. Through our distributors
• Fullyautomated batch process                  in Europe, Africa, America and Asia, our international activities repre-
• By one-day trained operators                  sent 80 % of our turnover.
• Low maintenance system
                                                We have references in the following countries: Albania, Algeria, Argentina, Azerbaijan, Bosnia, Brazil, Cameroon,
                                                Canada, China, Cyprus, Denmark, Ecuador, Egypt, France, French Guyana, French Polynesia, Gabon, Ghana,
                                                Greece, Guadeloupe, Honduras, Hungary, India, Iran, Iraq, Ivory Cost, Jamaica, Japan, Jordan, Kosovo,
    Reliable:
• Equipped  with safety systems
                                                Kurdistan, Kuwait, Latvia, Lebanon, Libya, Mauritania, Mayotte, Mexico, Morocco, New Caledonia, Nigeria,
• Shredding  and sterilization occur            Panama, Peru, Poland, Reunion Island, Romania, Russia, Saint-Lucia, Saint-Pierre et Miquelon, Slovakia,
  in a closed and compact system                Spain, Sudan, Syria, Tunisia, Turkey, Turkmenistan, Ukraine, UAE, United Kingdom, USA, Venezuela…
• No intermediate handling
  of the waste



    Effective:
• Renders    the waste unrecognizable
• Pre-shredding permits an effective
  sterilization to the core of the waste
• 80% volume reduction
  of treated waste



    Environmentally                        > Countries in which
    responsible:                             ECODAS systems
• Clean and Environmentally friendly         are installed
  technology
• No hazardous emissions




                                                                                                                                                                          Taking control
• Chemical-free process
• No Radiation
• Allows on-site treatment of waste




                                                                                                                                                                          of your waste
    Economical:
• Easy  to install on hospital sites:                                                                                                 ECODAS
  no external transport needed
  for waste treatment.                                                                                                                28 rue Sébastopol
• Cost reduction in the treatment               ECODAS process has been tested by Pasteur Institute of Lille and                      59100 ROUBAIX
  and management of infectious                  approved by the Higher Council of Public Health of France since 1994,                 FRANCE
  waste.                                        under the supervision of the Ministry of Health and the Ministry of the
• Reduces the waste producer’s
  liability created by off-site
                                                Environment.
                                                                                                                                      contact@ecodas.com
  treatment process                             ECODAS Systems are designed and manufactured in accordance with the                   tel. +333 20 70 98 65
                                                following norms: ASME (The American Society of Mechanical Engineers),
                                                                                                                                      fax +333 20 36 28 05
                                                MLSE (China), CE (European Directives), MHLW (Japanese Ministry of
                                                Health, Labor and Welfare) and GOSSTANDART (Russia).
                                                The quality assurance of ECODAS systems is executed following
                                                                                                                                      www.ecodas.com
                                                ISO9001 : 2008 standards.


                                                ASME                                                                                  ENGINEERED SOLUTIONS FOR
                                                                                                                                      HEALTHCARE & THE ENVIRONMENT
                                                                                                                                                                     ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT


                                               HEALTHCARE & THE ENVIRONMENT
                                               ENGINEERED SOLUTIONS FOR
Our Solution:
 Safety in One Step                                                                                                             The ECODAS Treatment Cycle                                                      ACCURATE RECORD KEEPING
                                                                                                                                                                                                                Sample of Treatment Cycle Report
                                                                                                                                 1        Loading: The contaminated waste is automatically loaded
                                                                                                                                            into the upper chamber at the top of the unit.
 Medical Waste is often used to describe wastes generated
                                                                                                                                                                                                                           ECODAS T2000
 during the diagnosis and treatment of humans or animals, and
 it is capable of producing infectious diseases. Medical Waste                                                                                                                                                             Cycle n° 111294
                                                                                                                                               2    Shredding: After the loading cover is sealed,
 includes cultures and stocks, pathological wastes, blood products,                                                                                  the heavy-duty shredder cuts the material
                                                                                                                                                                                                             Date 25.01.2002                 Time 13.41
 sharps, tissue paper, plastic, glass, etc…                                                                                                           into small pieces and features a unique
                                                                                                                                                                                                                         Time        Waste       Pres
                                                                                                                                                        reversing system to avoid jamming.
                                                                                                                                                                                                                                     Temp
 Healthcare facilities must monitor and eliminate the generated                                                                                                                                                                      °C          bar
 waste without endangering the public health and the environment.                                                                                                                                            Loading     13.41        62         0.0
                                                                                                                                                          3     Heating: Saturated pressurized steam
                                                                                                                                                                 raises the temperature to 138°C             Step time 3.30
 ECODAS has developed an innovative, fully enclosed and                                                                                                           (280 F), and the pressure
                                                                                                                                                                                                             Shredding 13.45          62         0.0
                                                                                                                                                                   to 3.8 bar (55 psi).
 automated system to sterilize medical waste, reduce its volume,
                                                                                                                                                                                                             Step time 21.00
 and render its components unrecognizable. Our patented
                                                                                                                                                                                                             Heating     14.06        61         0.0
 process combines shredding, direct heated steam, and high
                                                                                                                                                                    4 Sterilization: The pressurized         Heating     14.07       120         1.5
 pressure to achieve complete sterilization of infectious materials.                                                                                                  heated steam comes into direct
 The final treated waste is harmless and safe to dispose of as                                                                                                          contact with the shredded material,   Heating     14.08       135         3.5
 ordinary municipal waste.                                                                                                                                             8Log10 reduction of the infectious    Heating     14.09       138         4.0
                                                                                                                                                                        load is achieved by maintaining
                                                                                                                                                                        138°C/3.8 bar for 10 minutes.        Step time 4.13
                                                                                                                                                                                                             Standing 14.10          138         4.0
                                                                                                                                                                                                             Standing 14.11          138         4.0
                                                                                                                                                                     5    Cooling: Temperature is lowered    Standing 14.12          138         4.0
                                                                                                                                                                          to 80°C by spraying cool water
                                                                                                                                                                          onto the double Jacket of          Standing 14.13          138         4.0
                                                                                                                                                                          the treatment vessel.              Standing 14.14          138         4.0
T100               T150/T300         T1000/T2000                                                                                                                         Simultaneously, the unit
                                                                                                                                                                         returns to ambient pressure.        Standing 14.15          138         4.0
                                                                                                                                                                                                             Standing 14.16          138         4.0
                                                                                                                                                                                                             Standing 14.17          138         4.0
                                                                                                                                                                6      Draining: The steam is condensed      Standing 14.18          138         4.0
                                                                                                                                                                      to water and discharged with
                                                                                                                                                                     the cooling water to the sanitary       Standing 14.19          138         4.0
                                                                       Five models available                                                                        sewer system.                            Step time 10.00
                                                                       with different capacities
                                                                                                                                                                                                             Cooling     14.20       136         3.7
                                                                       to suit your needs:
                                                                       ECODAS T100, T150, T300,                                                                                                              Cooling     14.21       134         3.4
                                                                                                                                                      7        Vacuum: The remaining residual steam
                                                                       T1000 and T2000.                                                                       is vented out through a vacuum pump.           Cooling     14.22       130         2.9
                                                                                                                                                                                                             Cooling     14.23       125         2.1

                         ECODAS                                                                                                                8    Unloading: A digital signal informs the operator
                                                                                                                                                                                                             Cooling
                                                                                                                                                                                                             Cooling
                                                                                                                                                                                                                         14.24
                                                                                                                                                                                                                         14.25
                                                                                                                                                                                                                                      75         0.5



                         A World-class Manufacturer                                                                                               that all safe operating conditions have been met.
                                                                                                                                                The condition unlocks the unit and allows gravity
                                                                                                                                               unloading of the treated waste into a container.
                                                                                                                                                                                                             Step time 5.00
                                                                                                                                                                                                             Draining    14.25        75         0.0

                         We design, manufacture and supply automated solutions for                                                                                                                           Step time 4.40
                         medical waste treatment worldwide. For more than twenty                                                                                                                             Vaccum      14.30        75        - 0.4
                         years, the ECODAS team has developed a wide expertise in                                                    °C                                                                      Step time 2.50           75
                         pressurized thermal machine manufacturing for the textile,                                                                                                                          Unloading 14.32
                         food processing and medical waste industries, providing high                                                                                                                        Step time 2.10                      0.0
                         value solutions based on advanced technologies.                                                                                                                                     Date 25.01.2002                 Time 14.35
                         ECODAS is adopting a sustainable development strategy by                                                                                                                                       Cycle Time           53 mn
                         creating robust systems while using recyclable components                                                                                                                                            Cycle OK
                         from the world’s leader manufacturers.
                                                                                                   T 2000 Sterilisation Cycle
> PROCESS VOLUME CAPACITY
                     T 100                                      100 Liters per Cycle


                                                          Our Solution,
                                                          Safety in One Step
                                                          Our patented process is designed to sterilize
                                                          medical waste, reduce its volume, and render
                                                          its components unrecognizable all in one
                                                          fully enclosed and automated system.
                                                          It combines direct heated steam, high pressure
                                                          and shredding to treat infectious materials.
                                                          The contaminated waste is loaded into the upper stainless
                                                          steel chamber where a heavy-duty shredder reduces the
                                                          waste into small pieces.

                                                          Using gravity, the processed material falls into the
                                                          treatment chamber, where every particle is steam
                                                          heated to 138°C (280 F) and pressurized to 3.8 bar
  APPROVED BY THE HIGHER COUNCIL                          (55 psi) for 10 minutes. The operating conditions are
  OF PUBLIC HEALTH OF FRANCE,                             continuously monitored and validated to achieve complete
  UNDER THE SUPERVISION OF THE                            sterilization.
  MINISTRY OF HEALTH AND THE
                                                          After the cooling process, the ¼OBM product is
  MINISTRY OF THE ENVIRONMENT.                            volume-reduced (by up to 80%), unrecognizable and
                                                          safe to dispose of as ordinary municipal waste.

                                                          The 30 minutes average duration process cycle is totally
                                                          automated. A computerized system monitors the process
                                                          and automatically prints a report with the essential
                                                          sterilizing parameters at the end of the cycle for
                                                          accurate record keeping.


ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT
                                                                  ASME
> PROCESS VOLUME CAPACITY
                           T 100                                                              100 Liters per Cycle


                                                              > TECHNICAL SPECIFICATIONS
                                                                     General Characteristics
                                                                        - Dimensions (L x W x H). cm                  191 x 115 x 207
                                                                        - Dimensions (L x W x H). ft                   6.3x 3.8x 6.8
                                                                        - Shipping Weight. kg                              635
                                                                        - Max Weight when klled with water.
                                                                                                                           780
                                                                          For a special hydraulic test. kg
                                                                        - Stress. kg/cm2                                    0.1
                                                                        - Steam Pressure. Bar                                8
                                                                        - Max Steam Flow. kg/h                              35
                                                               207




                                                                        - Compressed Air. Bar                                6
                                                                        - Electricity 380 V / 3-Phase                     3.2 kW
                                                                     Operating Characteristics
                                                                        - Average Cycle Time. minutes                       30
                                                                        - Process Volume Capacity. liters                  100
                                                                        - Average Waste Density. kg/m3                   100 - 150
                                                                        - Average Process Weight Capacity. kg/Cycle       10 - 15
                                                                        - Average Process Weight Capacity. lb/Cycle       22 - 33
                                                                                                                          8 log 10
                                                          5




                                                                        - Microbial Inactivation
                                                        11




                                                                        - Waste Volume Reduction                           80%
                  191                                                Consumption / Cycle
                                                                        - Steam. kg                                         6
                                                                        - Electricity. kW/h                                0,55
                                                                        - Water. liters                                     5




ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT

28 rue Sébastopol
59100 ROUBAIX -FRANCE

contact@ecodas.com
tél. +333 20 70 98 65 - fax +333 20 36 28 05

www.ecodas.com
T 150                               > PROCESS VOLUME CAPACITY
                                                                 150 Liters per Cycle


                                                          Our Solution,
                                                          Safety in One Step
                                                          Our patented process is designed to sterilize
                                                          medical waste, reduce its volume, and render
                                                          its components unrecognizable all in one
                                                          fully enclosed and automated system.
                                                          It combines direct heated steam, high pressure
                                                          and shredding to treat infectious materials.

                                                           The contaminated waste is loaded into the upper stainless
                                                           steel chamber where a heavy-duty shredder reduces the
                                                           waste into small pieces.

                                                           Using gravity, the processed material falls into the
                                                           treatment chamber, where every particle is steam
                                                           heated to 138°C (280 F) and pressurized to 3.8 bar
                                                           (55 psi) for 10 minutes. The operating conditions are
                                                           continuously monitored and validated to achieve complete
                                                           sterilization.

                                                           After the cooling process, the final product is
  APPROVED BY THE HIGHER COUNCIL                           volume-reduced (by up to 80%), unrecognizable and
  OF PUBLIC HEALTH OF FRANCE,                              safe to dispose of as ordinary municipal waste.
  UNDER THE SUPERVISION OF THE
                                                           The 30 minutes average duration process cycle is totally
  MINISTRY OF HEALTH AND THE                               automated. A computerized system monitors the process
  MINISTRY OF THE ENVIRONMENT.                             and automatically prints a report with the essential
                                                           sterilizing parameters at the end of the cycle for
                                                           accurate record keeping.




ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT
                                                                   ASME
T 150                                      > PROCESS VOLUME CAPACITY
                                                                                  150 Liters per Cycle


                                                 > TECHNICAL SPECIFICATIONS
                                                         General Characteristics
                                                            - Dimensions (L x W x H). cm                  210 x 220 x 275
                                                            - Dimensions (L x W x H). ft                   6.9 x 7.2 x 9
                                                            - Shipping Weight. kg                               800
                                                            - Max Weight when filled with water.
                                                                                                              1100
                                                              For a special hydraulic test. kg
                                                            - Stress. kg/cm2                                     1
                                                            - Steam Pressure. Bar                                8


                                                   275
                                                   750
                                                 23334
                                                            - Max Steam Flow. kg/h                             65
                                                            - Compressed Air. Bar                                6
                                                            - Electricity 380 V / 3-Phase                     8 kW
                                                         Operating Characteristics
                                                            - Average Cycle Time. minutes                       30
                                                            - Process Volume Capacity. liters                   150
                                                            - Average Waste Density. kg/m3                  100 -150
110




                                                            - Average Process Weight Capacity. kg/Cycle       15 - 23
                                           0
                                         22




                                                            - Average Process Weight Capacity. lb/Cycle       33 - 51
             210
                                                            - Microbial Inactivation                         8 log 10
                                                            - Waste Volume Reduction                           80%
                                                         Consumption / Cycle
                                                            - Steam. kg                                         9
                                                            - Electricity. kW/h                                1.4
                                                            - Water. liters                                    15

                                                          Some of our customers :
                                                          Azerbaijan, Cameroon, France,
                                                          Gabon, Ghana, India, Iran,
                                                          Iraq, Kurdistan, Kuwait, Libya,
                                                          Panama, Russia, St Pierre et
                                                          Miquelon, Sudan, Turkey...

ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT

  28 rue Sébastopol
  59100 ROUBAIX -FRANCE

  contact@ecodas.com
  tél. +333 20 70 98 65 - fax +333 20 36 28 05

  www.ecodas.com
T 300                               > PROCESS VOLUME CAPACITY
                                                            350 Liters per Cycle

                                                          Our Solution,
                                                          Safety in One Step
                                                          Our patented process is designed to sterilize
                                                          medical waste, reduce its volume, and render
                                                          its components unrecognizable all in one
                                                          fully enclosed and automated system.
                                                          It combines direct heated steam, high pressure
                                                          and shredding to treat infectious materials.



                                                           The contaminated waste is loaded into the upper stainless
                                                           steel chamber where a heavy-duty shredder reduces the
                                                           waste into small pieces.

                                                           Using gravity, the processed material falls into the
                                                           treatment chamber, where every particle is steam
                                                           heated to 138°C (280 F) and pressurized to 3.8 bar
                                                           (55 psi) for 10 minutes. The operating conditions are
                                                           continuously monitored and validated to achieve complete
                                                           sterilization.

                                                           After the cooling process, the final product is
                                                           volume-reduced (by up to 80%), unrecognizable and
                                                           safe to dispose of as ordinary municipal waste.

                                                           The 30 minutes average duration process cycle is totally
                                                           automated. A computerized system monitors the process
  APPROVED BY THE HIGHER COUNCIL                           and automatically prints a report with the essential
  OF PUBLIC HEALTH OF FRANCE,                              sterilizing parameters at the end of the cycle for
  UNDER THE SUPERVISION OF THE                             accurate record keeping.
  MINISTRY OF HEALTH AND THE
  MINISTRY OF THE ENVIRONMENT.




ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT
                                                                   ASME
T 300                    > PROCESS VOLUME CAPACITY
                                                            350 Liters per Cycle


                                                   > TECHNICAL SPECIFICATIONS
                                                           General Characteristics
                                                              - Dimensions (L x W x H). cm                            220x 250 x 330
                                                              - Dimensions (L x W x H). ft                            7.2 x 8.2 x 10.8
                                                              - Shipping Weight. kg                                        2000
                                                              - Max Weight when filled with water.
                                                                                                                           3100
                                                                For a special hydraulic test. kg
                                                              - Stress. kg/cm2                                              2
                                                              - Steam Pressure. Bar                                         8
                                                              - Max Steam Flow. kg/h                                       170

                                                     330
                                                              - Compressed Air. Bar                                         6
                                                              - Electricity 380 V / 3-Phase Surge Protection System       14 kW
                                                           Operating Characteristics
                                                              - Average Cycle Time. minutes                                  30
                                                              - Process Volume Capacity. liters                             350
                                                              - Average Waste Density. kg/m3                             100 -150
                                                              - Average Process Weight Capacity. kg/Cycle                 35 - 52
                                                              - Average Process Weight Capacity. lb/Cycle                 77 - 115
116
116




                                                              - Microbial Inactivation                                     8 log10
                                               0
                                             25




                                                              - Waste Volume Reduction                                      80%
              220
              220
                                                           Consumption / Cycle
                                                              - Steam. kg                                                   15
                                                              - Electricity. kW/h                                           1,7
                                                              - Water. liters                                               25




                                                               Some of our customers :
                                                            Albania, Algeria, Bosnia, Cyprus,
                                                            Egypt, France, French Guyana,
                                                            French Polynesia, Iran, Ivory
                                                            Cost, Japan, Jordan, Kosovo,
                                                            Kuwait, Latvia, Lebanon, Libya,
      ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT Mauritania, Mayotte, Mexico,
                                                            Morocco, Panama, Poland,
        28 rue Sébastopol                                   Reunion Island, Romania,
        59100 ROUBAIX -FRANCE                               Russia, Slovakia, Syria,
                                                            Tunisia, Turkey, Ukraine, UAE,
        contact@ecodas.com                                  Venezuela...
        tél. +333 20 70 98 65 - fax +333 20 36 28 05

        www.ecodas.com
> PROCESS VOLUME CAPACITY
                    T 1000                          1100 Liters per Cycle

                                                        Our Solution,
                                                        Safety in One Step
                                                        Our patented process is designed to sterilize
                                                        medical waste, reduce its volume, and render
                                                        its components unrecognizable all in one
                                                        fully enclosed and automated system.
                                                        It combines direct heated steam, high pressure
                                                        and shredding to treat infectious materials.



                                                        The contaminated waste is loaded into the upper stainless
                                                        steel chamber where a heavy-duty shredder reduces the
                                                        waste into small pieces.

                                                        Using gravity, the processed material falls into the
                                                        treatment chamber, where every particle is steam
                                                        heated to 138°C (280 F) and pressurized to 3.8 bar
                                                        (55 psi) for 10 minutes. The operating conditions are
                                                        continuously monitored and validated to achieve complete
                                                        sterilization.

                                                        After the cooling process, the final product is
                                                        volume-reduced (by up to 80%), unrecognizable and
                                                        safe to dispose of as ordinary municipal waste.

                                                        The 35 minutes average duration process cycle is totally
                                                        automated. A computerized system monitors the process
                                                        and automatically prints a report with the essential
                                                        sterilizing parameters at the end of the cycle for
                                                        accurate record keeping.


  APPROVED BY THE HIGHER COUNCIL
  OF PUBLIC HEALTH OF FRANCE,
  UNDER THE SUPERVISION OF THE
  MINISTRY OF HEALTH AND THE
  MINISTRY OF THE ENVIRONMENT.




                                                              ASME
ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT
T 1000                     > PROCESS VOLUME CAPACITY
                                                         1100 Liters per Cycle


                                                 > TECHNICAL SPECIFICATIONS
                                                            General Characteristics
                                                               - Dimensions (L x W x H). cm                            600 x 440 x 633
                                                               - Dimensions (L x W x H). ft                            19.7 x 14.4 x 21
                                                               - Shipping Weight. kg                                        2800
                                                               - Max Weight when filled with water.
                                                                                                                            5000
                                                                 For a special hydraulic test. kg
                                                               - Stress. kg/cm2                                             2.5
                                                               - Steam Pressure. Bar                                         8
                                                               - Max Steam Flow. kg/h                                       370
633




                                                               - Compressed Air. Bar
633




                                                                                                                             6
                                                               - Electricity 380 V / 3-Phase Surge Protection System       20 kW
                                                            Operating Characteristics
                                                      455
                                                      455




                                                               - Average Cycle Time. minutes                                  35
                                                360
                                                360




                                                               - Process Volume Capacity. liters                            1100
                                                               - Average Waste Density. kg/m3                             100 - 150
                                                               - Average Process Weight Capacity. kg/Cycle                110 - 165
                                                               - Average Process Weight Capacity. lb/Cycle                242 - 364
                                                               - Microbial Inactivation                                   8 log 10
                                            0
               600                       440
                                         44                    - Waste Volume Reduction                                     80 %
                                                            Consumption / Cycle
                                                               - Steam. kg                                                   20
                                                               - Electricity. kW/h                                            4
                                                               - Water. liters                                               35


                                                              Some of our customers :
                                                              Egypt, France, Greece, Guadeloupe, Hungary, India, Kuwait,
                                                              Lebanon, Nigeria, Reunion Island, Saint Lucia, Syria, Turkey...




  ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT


      28 rue Sébastopol
      59100 ROUBAIX -FRANCE

      contact@ecodas.com
      tél. +333 20 70 98 65 - fax +333 20 36 28 05

      www.ecodas.com
> PROCESS VOLUME CAPACITY
                    T 2000                          2500 Liters per Cycle

                                                        Our Solution,
                                                        Safety in One Step
                                                        Our patented process is designed to sterilize
                                                        medical waste, reduce its volume, and render
                                                        its components unrecognizable all in one
                                                        fully enclosed and automated system.
                                                        It combines direct heated steam, high pressure
                                                        and shredding to treat infectious materials.




                                                                            The contaminated waste is loaded into
                                                                            the upper stainless steel chamber
                                                                            where a heavy-duty shredder reduces
                                                                            the waste into small pieces.

                                                        Using gravity, the processed material falls into the
                                                        treatment chamber, where every particle is steam
                                                        heated to 138°C (280 F) and pressurized to 3.8 bar
                                                        (55 psi) for 10 minutes. The operating conditions are
                                                        continuously monitored and validated to achieve complete
                                                        sterilization.


                                                                            After the cooling process, the final
                                                                            product is volume-reduced (by up
                                                                            to 80%), unrecognizable and safe
                                                                            to dispose of as ordinary municipal
                                                                            waste.


                                                        The 45 minutes average duration process cycle is totally
                                                        automated. A computerized system monitors the process
                                                        and automatically prints a report with the essential
                                                        sterilizing parameters at the end of the cycle for
                                                        accurate record keeping.


  APPROVED BY THE HIGHER COUNCIL
  OF PUBLIC HEALTH OF FRANCE,
  UNDER THE SUPERVISION OF THE
  MINISTRY OF HEALTH AND THE
  MINISTRY OF THE ENVIRONMENT.




                                                              ASME
ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT
> PROCESS VOLUME CAPACITY
                          T 2000                             2500 Liters per Cycle


                                                     > TECHNICAL SPECIFICATIONS
                                                                General Characteristics
                                                                   - Dimensions (L x W x H). cm                            600 x 440x 633
                                                                   - Dimensions (L x W x H). ft                            19.7 x 14.4 x 21
                                                                   - Shipping Weight. kg                                         5200
                                                                   - Max Weight when filled with water.
                                                                                                                                10500
                                                                     For a special hydraulic test. kg
                                                                   - Stress. kg/cm2                                             3.5
                                                                   - Steam Pressure. Bar                                         8
                                                                   - Max Steam Flow. kg/h                                       500
                                                                   - Compressed Air. Bar                                         6
                                                                   - Electricity 380 V / 3-Phase Surge Protection System       35 kW
633




                                                                Operating Characteristics
                                                                   - Average Cycle Time. minutes                                 45
                                                                   - Process Volume Capacity. liters                            2500
                                                          455




                                                                   - Average Waste Density. kg/m3
                                                    360




                                                                                                                              100 - 150
                                                                   - Average Process Weight Capacity. kg/Cycle                250 - 375
                                                                   - Average Process Weight Capacity. lb/Cycle                550 - 825
                                                                   - Microbial Inactivation                                    8 log 10
                                                                   - Waste Volume Reduction                                     80 %
                                                0
                                                                Consumption / Cycle
                 600                          44
                                                                   - Steam. kg                                                   40
                                                                   - Electricity. kW/h                                            9
                                                                   - Water. liters                                               50




                                                                        Some of our customers :
                                                                        Argentina, Brazil, China, Denmark, Ecuador, Egypt, France,
                                                                        French Guyana, Greece, Honduras, Jamaica, Mexico, New
                                                                        Caledonia, Panama, Renion Island, Spain, Tunisia, Turkey,
                                                                        Turkmenistan, United Kingdom, Venezuela...




      ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT


        28 rue Sébastopol
        59100 ROUBAIX -FRANCE

        contact@ecodas.com
        tél. +333 20 70 98 65 - fax +333 20 36 28 05

        www.ecodas.com

Contenu connexe

Similaire à Ecodas T-Series Brochure

Envirovation Solutions Presentation
Envirovation Solutions PresentationEnvirovation Solutions Presentation
Envirovation Solutions Presentationwmcdougall86
 
Green Tech Malaysia. Presentation by Soma Medical on GBI and Indoor Air Quali...
Green Tech Malaysia. Presentation by Soma Medical on GBI and Indoor Air Quali...Green Tech Malaysia. Presentation by Soma Medical on GBI and Indoor Air Quali...
Green Tech Malaysia. Presentation by Soma Medical on GBI and Indoor Air Quali...Indoor Air Sterilization Soma Medical IAQA
 
Sustainability in the Chemical Industry: From Theory to Practice - Oxiteno
Sustainability in the Chemical Industry: From Theory to Practice - OxitenoSustainability in the Chemical Industry: From Theory to Practice - Oxiteno
Sustainability in the Chemical Industry: From Theory to Practice - OxitenoRevista H&C
 
Advanced Cell Therapies - GMP Manufacturing
Advanced Cell Therapies - GMP Manufacturing Advanced Cell Therapies - GMP Manufacturing
Advanced Cell Therapies - GMP Manufacturing Comecer
 
Env protnandwastemanagement (1)
Env protnandwastemanagement (1)Env protnandwastemanagement (1)
Env protnandwastemanagement (1)Varsha Deva
 
BIO MEDICAL WASTE MANAGEMENT
BIO MEDICAL WASTE MANAGEMENTBIO MEDICAL WASTE MANAGEMENT
BIO MEDICAL WASTE MANAGEMENTSantosh Yadav
 
AIRsana slide share
AIRsana slide shareAIRsana slide share
AIRsana slide shareAIRsana
 
Breakthrough technologies for pharma wastewater treatment
Breakthrough technologies for pharma wastewater treatmentBreakthrough technologies for pharma wastewater treatment
Breakthrough technologies for pharma wastewater treatmentA.T.E. Private Limited
 
Uran plant presentation jounalist (6-7-2007)
Uran plant presentation    jounalist (6-7-2007)Uran plant presentation    jounalist (6-7-2007)
Uran plant presentation jounalist (6-7-2007)ajishdileep
 
Infection control 15
Infection control 15Infection control 15
Infection control 15colinmister
 
EezzeE Healthcare Presentation
EezzeE Healthcare PresentationEezzeE Healthcare Presentation
EezzeE Healthcare PresentationEezzeEUK
 
Bio-Microbics Company Overview
Bio-Microbics Company OverviewBio-Microbics Company Overview
Bio-Microbics Company OverviewBioMicrobics, Inc.
 
environmentalist certification
environmentalist certificationenvironmentalist certification
environmentalist certificationVskills
 
C22 0 introduction to cleaning_final-web
C22 0 introduction to cleaning_final-webC22 0 introduction to cleaning_final-web
C22 0 introduction to cleaning_final-webDir Jan
 
EnviroChemie - Wastewater treatment solutions for the pharmaceutical and life...
EnviroChemie - Wastewater treatment solutions for the pharmaceutical and life...EnviroChemie - Wastewater treatment solutions for the pharmaceutical and life...
EnviroChemie - Wastewater treatment solutions for the pharmaceutical and life...jose_canga
 
IAQ improvements for work spaces
IAQ improvements  for work spacesIAQ improvements  for work spaces
IAQ improvements for work spacesAsquareEngieering
 

Similaire à Ecodas T-Series Brochure (20)

Envirovation Solutions Presentation
Envirovation Solutions PresentationEnvirovation Solutions Presentation
Envirovation Solutions Presentation
 
Green Tech Malaysia. Presentation by Soma Medical on GBI and Indoor Air Quali...
Green Tech Malaysia. Presentation by Soma Medical on GBI and Indoor Air Quali...Green Tech Malaysia. Presentation by Soma Medical on GBI and Indoor Air Quali...
Green Tech Malaysia. Presentation by Soma Medical on GBI and Indoor Air Quali...
 
EWS General Brochure
EWS General Brochure  EWS General Brochure
EWS General Brochure
 
Sustainability in the Chemical Industry: From Theory to Practice - Oxiteno
Sustainability in the Chemical Industry: From Theory to Practice - OxitenoSustainability in the Chemical Industry: From Theory to Practice - Oxiteno
Sustainability in the Chemical Industry: From Theory to Practice - Oxiteno
 
First ehsms workshop
First ehsms workshopFirst ehsms workshop
First ehsms workshop
 
Advanced Cell Therapies - GMP Manufacturing
Advanced Cell Therapies - GMP Manufacturing Advanced Cell Therapies - GMP Manufacturing
Advanced Cell Therapies - GMP Manufacturing
 
Vasundhara_ConsultancyProfile
Vasundhara_ConsultancyProfileVasundhara_ConsultancyProfile
Vasundhara_ConsultancyProfile
 
Env protnandwastemanagement (1)
Env protnandwastemanagement (1)Env protnandwastemanagement (1)
Env protnandwastemanagement (1)
 
BIO MEDICAL WASTE MANAGEMENT
BIO MEDICAL WASTE MANAGEMENTBIO MEDICAL WASTE MANAGEMENT
BIO MEDICAL WASTE MANAGEMENT
 
AIRsana slide share
AIRsana slide shareAIRsana slide share
AIRsana slide share
 
Breakthrough technologies for pharma wastewater treatment
Breakthrough technologies for pharma wastewater treatmentBreakthrough technologies for pharma wastewater treatment
Breakthrough technologies for pharma wastewater treatment
 
Uran plant presentation jounalist (6-7-2007)
Uran plant presentation    jounalist (6-7-2007)Uran plant presentation    jounalist (6-7-2007)
Uran plant presentation jounalist (6-7-2007)
 
Infection control 15
Infection control 15Infection control 15
Infection control 15
 
EezzeE Healthcare Presentation
EezzeE Healthcare PresentationEezzeE Healthcare Presentation
EezzeE Healthcare Presentation
 
Bio-Microbics Company Overview
Bio-Microbics Company OverviewBio-Microbics Company Overview
Bio-Microbics Company Overview
 
environmentalist certification
environmentalist certificationenvironmentalist certification
environmentalist certification
 
C22 0 introduction to cleaning_final-web
C22 0 introduction to cleaning_final-webC22 0 introduction to cleaning_final-web
C22 0 introduction to cleaning_final-web
 
EnviroChemie - Wastewater treatment solutions for the pharmaceutical and life...
EnviroChemie - Wastewater treatment solutions for the pharmaceutical and life...EnviroChemie - Wastewater treatment solutions for the pharmaceutical and life...
EnviroChemie - Wastewater treatment solutions for the pharmaceutical and life...
 
Biomedical waste management
Biomedical waste managementBiomedical waste management
Biomedical waste management
 
IAQ improvements for work spaces
IAQ improvements  for work spacesIAQ improvements  for work spaces
IAQ improvements for work spaces
 

Ecodas T-Series Brochure

  • 1. SHREDDING AND STERILIZATION OF MEDICAL WASTE ECODAS A Global Presence Advantages: ECODAS process can be used by various healthcare facilities or their medical waste treatment service providers. We are the leader in providing an alternative medical waste treatment Easy to use: technology in many countries around the world. Through our distributors • Fullyautomated batch process in Europe, Africa, America and Asia, our international activities repre- • By one-day trained operators sent 80 % of our turnover. • Low maintenance system We have references in the following countries: Albania, Algeria, Argentina, Azerbaijan, Bosnia, Brazil, Cameroon, Canada, China, Cyprus, Denmark, Ecuador, Egypt, France, French Guyana, French Polynesia, Gabon, Ghana, Greece, Guadeloupe, Honduras, Hungary, India, Iran, Iraq, Ivory Cost, Jamaica, Japan, Jordan, Kosovo, Reliable: • Equipped with safety systems Kurdistan, Kuwait, Latvia, Lebanon, Libya, Mauritania, Mayotte, Mexico, Morocco, New Caledonia, Nigeria, • Shredding and sterilization occur Panama, Peru, Poland, Reunion Island, Romania, Russia, Saint-Lucia, Saint-Pierre et Miquelon, Slovakia, in a closed and compact system Spain, Sudan, Syria, Tunisia, Turkey, Turkmenistan, Ukraine, UAE, United Kingdom, USA, Venezuela… • No intermediate handling of the waste Effective: • Renders the waste unrecognizable • Pre-shredding permits an effective sterilization to the core of the waste • 80% volume reduction of treated waste Environmentally > Countries in which responsible: ECODAS systems • Clean and Environmentally friendly are installed technology • No hazardous emissions Taking control • Chemical-free process • No Radiation • Allows on-site treatment of waste of your waste Economical: • Easy to install on hospital sites: ECODAS no external transport needed for waste treatment. 28 rue Sébastopol • Cost reduction in the treatment ECODAS process has been tested by Pasteur Institute of Lille and 59100 ROUBAIX and management of infectious approved by the Higher Council of Public Health of France since 1994, FRANCE waste. under the supervision of the Ministry of Health and the Ministry of the • Reduces the waste producer’s liability created by off-site Environment. contact@ecodas.com treatment process ECODAS Systems are designed and manufactured in accordance with the tel. +333 20 70 98 65 following norms: ASME (The American Society of Mechanical Engineers), fax +333 20 36 28 05 MLSE (China), CE (European Directives), MHLW (Japanese Ministry of Health, Labor and Welfare) and GOSSTANDART (Russia). The quality assurance of ECODAS systems is executed following www.ecodas.com ISO9001 : 2008 standards. ASME ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT HEALTHCARE & THE ENVIRONMENT ENGINEERED SOLUTIONS FOR
  • 2. Our Solution: Safety in One Step The ECODAS Treatment Cycle ACCURATE RECORD KEEPING Sample of Treatment Cycle Report 1 Loading: The contaminated waste is automatically loaded into the upper chamber at the top of the unit. Medical Waste is often used to describe wastes generated ECODAS T2000 during the diagnosis and treatment of humans or animals, and it is capable of producing infectious diseases. Medical Waste Cycle n° 111294 2 Shredding: After the loading cover is sealed, includes cultures and stocks, pathological wastes, blood products, the heavy-duty shredder cuts the material Date 25.01.2002 Time 13.41 sharps, tissue paper, plastic, glass, etc… into small pieces and features a unique Time Waste Pres reversing system to avoid jamming. Temp Healthcare facilities must monitor and eliminate the generated °C bar waste without endangering the public health and the environment. Loading 13.41 62 0.0 3 Heating: Saturated pressurized steam raises the temperature to 138°C Step time 3.30 ECODAS has developed an innovative, fully enclosed and (280 F), and the pressure Shredding 13.45 62 0.0 to 3.8 bar (55 psi). automated system to sterilize medical waste, reduce its volume, Step time 21.00 and render its components unrecognizable. Our patented Heating 14.06 61 0.0 process combines shredding, direct heated steam, and high 4 Sterilization: The pressurized Heating 14.07 120 1.5 pressure to achieve complete sterilization of infectious materials. heated steam comes into direct The final treated waste is harmless and safe to dispose of as contact with the shredded material, Heating 14.08 135 3.5 ordinary municipal waste. 8Log10 reduction of the infectious Heating 14.09 138 4.0 load is achieved by maintaining 138°C/3.8 bar for 10 minutes. Step time 4.13 Standing 14.10 138 4.0 Standing 14.11 138 4.0 5 Cooling: Temperature is lowered Standing 14.12 138 4.0 to 80°C by spraying cool water onto the double Jacket of Standing 14.13 138 4.0 the treatment vessel. Standing 14.14 138 4.0 T100 T150/T300 T1000/T2000 Simultaneously, the unit returns to ambient pressure. Standing 14.15 138 4.0 Standing 14.16 138 4.0 Standing 14.17 138 4.0 6 Draining: The steam is condensed Standing 14.18 138 4.0 to water and discharged with the cooling water to the sanitary Standing 14.19 138 4.0 Five models available sewer system. Step time 10.00 with different capacities Cooling 14.20 136 3.7 to suit your needs: ECODAS T100, T150, T300, Cooling 14.21 134 3.4 7 Vacuum: The remaining residual steam T1000 and T2000. is vented out through a vacuum pump. Cooling 14.22 130 2.9 Cooling 14.23 125 2.1 ECODAS 8 Unloading: A digital signal informs the operator Cooling Cooling 14.24 14.25 75 0.5 A World-class Manufacturer that all safe operating conditions have been met. The condition unlocks the unit and allows gravity unloading of the treated waste into a container. Step time 5.00 Draining 14.25 75 0.0 We design, manufacture and supply automated solutions for Step time 4.40 medical waste treatment worldwide. For more than twenty Vaccum 14.30 75 - 0.4 years, the ECODAS team has developed a wide expertise in °C Step time 2.50 75 pressurized thermal machine manufacturing for the textile, Unloading 14.32 food processing and medical waste industries, providing high Step time 2.10 0.0 value solutions based on advanced technologies. Date 25.01.2002 Time 14.35 ECODAS is adopting a sustainable development strategy by Cycle Time 53 mn creating robust systems while using recyclable components Cycle OK from the world’s leader manufacturers. T 2000 Sterilisation Cycle
  • 3. > PROCESS VOLUME CAPACITY T 100 100 Liters per Cycle Our Solution, Safety in One Step Our patented process is designed to sterilize medical waste, reduce its volume, and render its components unrecognizable all in one fully enclosed and automated system. It combines direct heated steam, high pressure and shredding to treat infectious materials. The contaminated waste is loaded into the upper stainless steel chamber where a heavy-duty shredder reduces the waste into small pieces. Using gravity, the processed material falls into the treatment chamber, where every particle is steam heated to 138°C (280 F) and pressurized to 3.8 bar APPROVED BY THE HIGHER COUNCIL (55 psi) for 10 minutes. The operating conditions are OF PUBLIC HEALTH OF FRANCE, continuously monitored and validated to achieve complete UNDER THE SUPERVISION OF THE sterilization. MINISTRY OF HEALTH AND THE After the cooling process, the ¼OBM product is MINISTRY OF THE ENVIRONMENT. volume-reduced (by up to 80%), unrecognizable and safe to dispose of as ordinary municipal waste. The 30 minutes average duration process cycle is totally automated. A computerized system monitors the process and automatically prints a report with the essential sterilizing parameters at the end of the cycle for accurate record keeping. ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT ASME
  • 4. > PROCESS VOLUME CAPACITY T 100 100 Liters per Cycle > TECHNICAL SPECIFICATIONS General Characteristics - Dimensions (L x W x H). cm 191 x 115 x 207 - Dimensions (L x W x H). ft 6.3x 3.8x 6.8 - Shipping Weight. kg 635 - Max Weight when klled with water. 780 For a special hydraulic test. kg - Stress. kg/cm2 0.1 - Steam Pressure. Bar 8 - Max Steam Flow. kg/h 35 207 - Compressed Air. Bar 6 - Electricity 380 V / 3-Phase 3.2 kW Operating Characteristics - Average Cycle Time. minutes 30 - Process Volume Capacity. liters 100 - Average Waste Density. kg/m3 100 - 150 - Average Process Weight Capacity. kg/Cycle 10 - 15 - Average Process Weight Capacity. lb/Cycle 22 - 33 8 log 10 5 - Microbial Inactivation 11 - Waste Volume Reduction 80% 191 Consumption / Cycle - Steam. kg 6 - Electricity. kW/h 0,55 - Water. liters 5 ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT 28 rue Sébastopol 59100 ROUBAIX -FRANCE contact@ecodas.com tél. +333 20 70 98 65 - fax +333 20 36 28 05 www.ecodas.com
  • 5. T 150 > PROCESS VOLUME CAPACITY 150 Liters per Cycle Our Solution, Safety in One Step Our patented process is designed to sterilize medical waste, reduce its volume, and render its components unrecognizable all in one fully enclosed and automated system. It combines direct heated steam, high pressure and shredding to treat infectious materials. The contaminated waste is loaded into the upper stainless steel chamber where a heavy-duty shredder reduces the waste into small pieces. Using gravity, the processed material falls into the treatment chamber, where every particle is steam heated to 138°C (280 F) and pressurized to 3.8 bar (55 psi) for 10 minutes. The operating conditions are continuously monitored and validated to achieve complete sterilization. After the cooling process, the final product is APPROVED BY THE HIGHER COUNCIL volume-reduced (by up to 80%), unrecognizable and OF PUBLIC HEALTH OF FRANCE, safe to dispose of as ordinary municipal waste. UNDER THE SUPERVISION OF THE The 30 minutes average duration process cycle is totally MINISTRY OF HEALTH AND THE automated. A computerized system monitors the process MINISTRY OF THE ENVIRONMENT. and automatically prints a report with the essential sterilizing parameters at the end of the cycle for accurate record keeping. ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT ASME
  • 6. T 150 > PROCESS VOLUME CAPACITY 150 Liters per Cycle > TECHNICAL SPECIFICATIONS General Characteristics - Dimensions (L x W x H). cm 210 x 220 x 275 - Dimensions (L x W x H). ft 6.9 x 7.2 x 9 - Shipping Weight. kg 800 - Max Weight when filled with water. 1100 For a special hydraulic test. kg - Stress. kg/cm2 1 - Steam Pressure. Bar 8 275 750 23334 - Max Steam Flow. kg/h 65 - Compressed Air. Bar 6 - Electricity 380 V / 3-Phase 8 kW Operating Characteristics - Average Cycle Time. minutes 30 - Process Volume Capacity. liters 150 - Average Waste Density. kg/m3 100 -150 110 - Average Process Weight Capacity. kg/Cycle 15 - 23 0 22 - Average Process Weight Capacity. lb/Cycle 33 - 51 210 - Microbial Inactivation 8 log 10 - Waste Volume Reduction 80% Consumption / Cycle - Steam. kg 9 - Electricity. kW/h 1.4 - Water. liters 15 Some of our customers : Azerbaijan, Cameroon, France, Gabon, Ghana, India, Iran, Iraq, Kurdistan, Kuwait, Libya, Panama, Russia, St Pierre et Miquelon, Sudan, Turkey... ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT 28 rue Sébastopol 59100 ROUBAIX -FRANCE contact@ecodas.com tél. +333 20 70 98 65 - fax +333 20 36 28 05 www.ecodas.com
  • 7. T 300 > PROCESS VOLUME CAPACITY 350 Liters per Cycle Our Solution, Safety in One Step Our patented process is designed to sterilize medical waste, reduce its volume, and render its components unrecognizable all in one fully enclosed and automated system. It combines direct heated steam, high pressure and shredding to treat infectious materials. The contaminated waste is loaded into the upper stainless steel chamber where a heavy-duty shredder reduces the waste into small pieces. Using gravity, the processed material falls into the treatment chamber, where every particle is steam heated to 138°C (280 F) and pressurized to 3.8 bar (55 psi) for 10 minutes. The operating conditions are continuously monitored and validated to achieve complete sterilization. After the cooling process, the final product is volume-reduced (by up to 80%), unrecognizable and safe to dispose of as ordinary municipal waste. The 30 minutes average duration process cycle is totally automated. A computerized system monitors the process APPROVED BY THE HIGHER COUNCIL and automatically prints a report with the essential OF PUBLIC HEALTH OF FRANCE, sterilizing parameters at the end of the cycle for UNDER THE SUPERVISION OF THE accurate record keeping. MINISTRY OF HEALTH AND THE MINISTRY OF THE ENVIRONMENT. ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT ASME
  • 8. T 300 > PROCESS VOLUME CAPACITY 350 Liters per Cycle > TECHNICAL SPECIFICATIONS General Characteristics - Dimensions (L x W x H). cm 220x 250 x 330 - Dimensions (L x W x H). ft 7.2 x 8.2 x 10.8 - Shipping Weight. kg 2000 - Max Weight when filled with water. 3100 For a special hydraulic test. kg - Stress. kg/cm2 2 - Steam Pressure. Bar 8 - Max Steam Flow. kg/h 170 330 - Compressed Air. Bar 6 - Electricity 380 V / 3-Phase Surge Protection System 14 kW Operating Characteristics - Average Cycle Time. minutes 30 - Process Volume Capacity. liters 350 - Average Waste Density. kg/m3 100 -150 - Average Process Weight Capacity. kg/Cycle 35 - 52 - Average Process Weight Capacity. lb/Cycle 77 - 115 116 116 - Microbial Inactivation 8 log10 0 25 - Waste Volume Reduction 80% 220 220 Consumption / Cycle - Steam. kg 15 - Electricity. kW/h 1,7 - Water. liters 25 Some of our customers : Albania, Algeria, Bosnia, Cyprus, Egypt, France, French Guyana, French Polynesia, Iran, Ivory Cost, Japan, Jordan, Kosovo, Kuwait, Latvia, Lebanon, Libya, ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT Mauritania, Mayotte, Mexico, Morocco, Panama, Poland, 28 rue Sébastopol Reunion Island, Romania, 59100 ROUBAIX -FRANCE Russia, Slovakia, Syria, Tunisia, Turkey, Ukraine, UAE, contact@ecodas.com Venezuela... tél. +333 20 70 98 65 - fax +333 20 36 28 05 www.ecodas.com
  • 9. > PROCESS VOLUME CAPACITY T 1000 1100 Liters per Cycle Our Solution, Safety in One Step Our patented process is designed to sterilize medical waste, reduce its volume, and render its components unrecognizable all in one fully enclosed and automated system. It combines direct heated steam, high pressure and shredding to treat infectious materials. The contaminated waste is loaded into the upper stainless steel chamber where a heavy-duty shredder reduces the waste into small pieces. Using gravity, the processed material falls into the treatment chamber, where every particle is steam heated to 138°C (280 F) and pressurized to 3.8 bar (55 psi) for 10 minutes. The operating conditions are continuously monitored and validated to achieve complete sterilization. After the cooling process, the final product is volume-reduced (by up to 80%), unrecognizable and safe to dispose of as ordinary municipal waste. The 35 minutes average duration process cycle is totally automated. A computerized system monitors the process and automatically prints a report with the essential sterilizing parameters at the end of the cycle for accurate record keeping. APPROVED BY THE HIGHER COUNCIL OF PUBLIC HEALTH OF FRANCE, UNDER THE SUPERVISION OF THE MINISTRY OF HEALTH AND THE MINISTRY OF THE ENVIRONMENT. ASME ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT
  • 10. T 1000 > PROCESS VOLUME CAPACITY 1100 Liters per Cycle > TECHNICAL SPECIFICATIONS General Characteristics - Dimensions (L x W x H). cm 600 x 440 x 633 - Dimensions (L x W x H). ft 19.7 x 14.4 x 21 - Shipping Weight. kg 2800 - Max Weight when filled with water. 5000 For a special hydraulic test. kg - Stress. kg/cm2 2.5 - Steam Pressure. Bar 8 - Max Steam Flow. kg/h 370 633 - Compressed Air. Bar 633 6 - Electricity 380 V / 3-Phase Surge Protection System 20 kW Operating Characteristics 455 455 - Average Cycle Time. minutes 35 360 360 - Process Volume Capacity. liters 1100 - Average Waste Density. kg/m3 100 - 150 - Average Process Weight Capacity. kg/Cycle 110 - 165 - Average Process Weight Capacity. lb/Cycle 242 - 364 - Microbial Inactivation 8 log 10 0 600 440 44 - Waste Volume Reduction 80 % Consumption / Cycle - Steam. kg 20 - Electricity. kW/h 4 - Water. liters 35 Some of our customers : Egypt, France, Greece, Guadeloupe, Hungary, India, Kuwait, Lebanon, Nigeria, Reunion Island, Saint Lucia, Syria, Turkey... ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT 28 rue Sébastopol 59100 ROUBAIX -FRANCE contact@ecodas.com tél. +333 20 70 98 65 - fax +333 20 36 28 05 www.ecodas.com
  • 11. > PROCESS VOLUME CAPACITY T 2000 2500 Liters per Cycle Our Solution, Safety in One Step Our patented process is designed to sterilize medical waste, reduce its volume, and render its components unrecognizable all in one fully enclosed and automated system. It combines direct heated steam, high pressure and shredding to treat infectious materials. The contaminated waste is loaded into the upper stainless steel chamber where a heavy-duty shredder reduces the waste into small pieces. Using gravity, the processed material falls into the treatment chamber, where every particle is steam heated to 138°C (280 F) and pressurized to 3.8 bar (55 psi) for 10 minutes. The operating conditions are continuously monitored and validated to achieve complete sterilization. After the cooling process, the final product is volume-reduced (by up to 80%), unrecognizable and safe to dispose of as ordinary municipal waste. The 45 minutes average duration process cycle is totally automated. A computerized system monitors the process and automatically prints a report with the essential sterilizing parameters at the end of the cycle for accurate record keeping. APPROVED BY THE HIGHER COUNCIL OF PUBLIC HEALTH OF FRANCE, UNDER THE SUPERVISION OF THE MINISTRY OF HEALTH AND THE MINISTRY OF THE ENVIRONMENT. ASME ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT
  • 12. > PROCESS VOLUME CAPACITY T 2000 2500 Liters per Cycle > TECHNICAL SPECIFICATIONS General Characteristics - Dimensions (L x W x H). cm 600 x 440x 633 - Dimensions (L x W x H). ft 19.7 x 14.4 x 21 - Shipping Weight. kg 5200 - Max Weight when filled with water. 10500 For a special hydraulic test. kg - Stress. kg/cm2 3.5 - Steam Pressure. Bar 8 - Max Steam Flow. kg/h 500 - Compressed Air. Bar 6 - Electricity 380 V / 3-Phase Surge Protection System 35 kW 633 Operating Characteristics - Average Cycle Time. minutes 45 - Process Volume Capacity. liters 2500 455 - Average Waste Density. kg/m3 360 100 - 150 - Average Process Weight Capacity. kg/Cycle 250 - 375 - Average Process Weight Capacity. lb/Cycle 550 - 825 - Microbial Inactivation 8 log 10 - Waste Volume Reduction 80 % 0 Consumption / Cycle 600 44 - Steam. kg 40 - Electricity. kW/h 9 - Water. liters 50 Some of our customers : Argentina, Brazil, China, Denmark, Ecuador, Egypt, France, French Guyana, Greece, Honduras, Jamaica, Mexico, New Caledonia, Panama, Renion Island, Spain, Tunisia, Turkey, Turkmenistan, United Kingdom, Venezuela... ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT 28 rue Sébastopol 59100 ROUBAIX -FRANCE contact@ecodas.com tél. +333 20 70 98 65 - fax +333 20 36 28 05 www.ecodas.com