1. SHREDDING AND STERILIZATION
OF MEDICAL WASTE
ECODAS
A Global Presence
Advantages: ECODAS process can be used by various healthcare facilities or their
medical waste treatment service providers.
We are the leader in providing an alternative medical waste treatment
Easy to use: technology in many countries around the world. Through our distributors
• Fullyautomated batch process in Europe, Africa, America and Asia, our international activities repre-
• By one-day trained operators sent 80 % of our turnover.
• Low maintenance system
We have references in the following countries: Albania, Algeria, Argentina, Azerbaijan, Bosnia, Brazil, Cameroon,
Canada, China, Cyprus, Denmark, Ecuador, Egypt, France, French Guyana, French Polynesia, Gabon, Ghana,
Greece, Guadeloupe, Honduras, Hungary, India, Iran, Iraq, Ivory Cost, Jamaica, Japan, Jordan, Kosovo,
Reliable:
• Equipped with safety systems
Kurdistan, Kuwait, Latvia, Lebanon, Libya, Mauritania, Mayotte, Mexico, Morocco, New Caledonia, Nigeria,
• Shredding and sterilization occur Panama, Peru, Poland, Reunion Island, Romania, Russia, Saint-Lucia, Saint-Pierre et Miquelon, Slovakia,
in a closed and compact system Spain, Sudan, Syria, Tunisia, Turkey, Turkmenistan, Ukraine, UAE, United Kingdom, USA, Venezuela…
• No intermediate handling
of the waste
Effective:
• Renders the waste unrecognizable
• Pre-shredding permits an effective
sterilization to the core of the waste
• 80% volume reduction
of treated waste
Environmentally > Countries in which
responsible: ECODAS systems
• Clean and Environmentally friendly are installed
technology
• No hazardous emissions
Taking control
• Chemical-free process
• No Radiation
• Allows on-site treatment of waste
of your waste
Economical:
• Easy to install on hospital sites: ECODAS
no external transport needed
for waste treatment. 28 rue Sébastopol
• Cost reduction in the treatment ECODAS process has been tested by Pasteur Institute of Lille and 59100 ROUBAIX
and management of infectious approved by the Higher Council of Public Health of France since 1994, FRANCE
waste. under the supervision of the Ministry of Health and the Ministry of the
• Reduces the waste producer’s
liability created by off-site
Environment.
contact@ecodas.com
treatment process ECODAS Systems are designed and manufactured in accordance with the tel. +333 20 70 98 65
following norms: ASME (The American Society of Mechanical Engineers),
fax +333 20 36 28 05
MLSE (China), CE (European Directives), MHLW (Japanese Ministry of
Health, Labor and Welfare) and GOSSTANDART (Russia).
The quality assurance of ECODAS systems is executed following
www.ecodas.com
ISO9001 : 2008 standards.
ASME ENGINEERED SOLUTIONS FOR
HEALTHCARE & THE ENVIRONMENT
ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT
HEALTHCARE & THE ENVIRONMENT
ENGINEERED SOLUTIONS FOR
2. Our Solution:
Safety in One Step The ECODAS Treatment Cycle ACCURATE RECORD KEEPING
Sample of Treatment Cycle Report
1 Loading: The contaminated waste is automatically loaded
into the upper chamber at the top of the unit.
Medical Waste is often used to describe wastes generated
ECODAS T2000
during the diagnosis and treatment of humans or animals, and
it is capable of producing infectious diseases. Medical Waste Cycle n° 111294
2 Shredding: After the loading cover is sealed,
includes cultures and stocks, pathological wastes, blood products, the heavy-duty shredder cuts the material
Date 25.01.2002 Time 13.41
sharps, tissue paper, plastic, glass, etc… into small pieces and features a unique
Time Waste Pres
reversing system to avoid jamming.
Temp
Healthcare facilities must monitor and eliminate the generated °C bar
waste without endangering the public health and the environment. Loading 13.41 62 0.0
3 Heating: Saturated pressurized steam
raises the temperature to 138°C Step time 3.30
ECODAS has developed an innovative, fully enclosed and (280 F), and the pressure
Shredding 13.45 62 0.0
to 3.8 bar (55 psi).
automated system to sterilize medical waste, reduce its volume,
Step time 21.00
and render its components unrecognizable. Our patented
Heating 14.06 61 0.0
process combines shredding, direct heated steam, and high
4 Sterilization: The pressurized Heating 14.07 120 1.5
pressure to achieve complete sterilization of infectious materials. heated steam comes into direct
The final treated waste is harmless and safe to dispose of as contact with the shredded material, Heating 14.08 135 3.5
ordinary municipal waste. 8Log10 reduction of the infectious Heating 14.09 138 4.0
load is achieved by maintaining
138°C/3.8 bar for 10 minutes. Step time 4.13
Standing 14.10 138 4.0
Standing 14.11 138 4.0
5 Cooling: Temperature is lowered Standing 14.12 138 4.0
to 80°C by spraying cool water
onto the double Jacket of Standing 14.13 138 4.0
the treatment vessel. Standing 14.14 138 4.0
T100 T150/T300 T1000/T2000 Simultaneously, the unit
returns to ambient pressure. Standing 14.15 138 4.0
Standing 14.16 138 4.0
Standing 14.17 138 4.0
6 Draining: The steam is condensed Standing 14.18 138 4.0
to water and discharged with
the cooling water to the sanitary Standing 14.19 138 4.0
Five models available sewer system. Step time 10.00
with different capacities
Cooling 14.20 136 3.7
to suit your needs:
ECODAS T100, T150, T300, Cooling 14.21 134 3.4
7 Vacuum: The remaining residual steam
T1000 and T2000. is vented out through a vacuum pump. Cooling 14.22 130 2.9
Cooling 14.23 125 2.1
ECODAS 8 Unloading: A digital signal informs the operator
Cooling
Cooling
14.24
14.25
75 0.5
A World-class Manufacturer that all safe operating conditions have been met.
The condition unlocks the unit and allows gravity
unloading of the treated waste into a container.
Step time 5.00
Draining 14.25 75 0.0
We design, manufacture and supply automated solutions for Step time 4.40
medical waste treatment worldwide. For more than twenty Vaccum 14.30 75 - 0.4
years, the ECODAS team has developed a wide expertise in °C Step time 2.50 75
pressurized thermal machine manufacturing for the textile, Unloading 14.32
food processing and medical waste industries, providing high Step time 2.10 0.0
value solutions based on advanced technologies. Date 25.01.2002 Time 14.35
ECODAS is adopting a sustainable development strategy by Cycle Time 53 mn
creating robust systems while using recyclable components Cycle OK
from the world’s leader manufacturers.
T 2000 Sterilisation Cycle
3. > PROCESS VOLUME CAPACITY
T 100 100 Liters per Cycle
Our Solution,
Safety in One Step
Our patented process is designed to sterilize
medical waste, reduce its volume, and render
its components unrecognizable all in one
fully enclosed and automated system.
It combines direct heated steam, high pressure
and shredding to treat infectious materials.
The contaminated waste is loaded into the upper stainless
steel chamber where a heavy-duty shredder reduces the
waste into small pieces.
Using gravity, the processed material falls into the
treatment chamber, where every particle is steam
heated to 138°C (280 F) and pressurized to 3.8 bar
APPROVED BY THE HIGHER COUNCIL (55 psi) for 10 minutes. The operating conditions are
OF PUBLIC HEALTH OF FRANCE, continuously monitored and validated to achieve complete
UNDER THE SUPERVISION OF THE sterilization.
MINISTRY OF HEALTH AND THE
After the cooling process, the ¼OBM product is
MINISTRY OF THE ENVIRONMENT. volume-reduced (by up to 80%), unrecognizable and
safe to dispose of as ordinary municipal waste.
The 30 minutes average duration process cycle is totally
automated. A computerized system monitors the process
and automatically prints a report with the essential
sterilizing parameters at the end of the cycle for
accurate record keeping.
ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT
ASME
4. > PROCESS VOLUME CAPACITY
T 100 100 Liters per Cycle
> TECHNICAL SPECIFICATIONS
General Characteristics
- Dimensions (L x W x H). cm 191 x 115 x 207
- Dimensions (L x W x H). ft 6.3x 3.8x 6.8
- Shipping Weight. kg 635
- Max Weight when klled with water.
780
For a special hydraulic test. kg
- Stress. kg/cm2 0.1
- Steam Pressure. Bar 8
- Max Steam Flow. kg/h 35
207
- Compressed Air. Bar 6
- Electricity 380 V / 3-Phase 3.2 kW
Operating Characteristics
- Average Cycle Time. minutes 30
- Process Volume Capacity. liters 100
- Average Waste Density. kg/m3 100 - 150
- Average Process Weight Capacity. kg/Cycle 10 - 15
- Average Process Weight Capacity. lb/Cycle 22 - 33
8 log 10
5
- Microbial Inactivation
11
- Waste Volume Reduction 80%
191 Consumption / Cycle
- Steam. kg 6
- Electricity. kW/h 0,55
- Water. liters 5
ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT
28 rue Sébastopol
59100 ROUBAIX -FRANCE
contact@ecodas.com
tél. +333 20 70 98 65 - fax +333 20 36 28 05
www.ecodas.com
5. T 150 > PROCESS VOLUME CAPACITY
150 Liters per Cycle
Our Solution,
Safety in One Step
Our patented process is designed to sterilize
medical waste, reduce its volume, and render
its components unrecognizable all in one
fully enclosed and automated system.
It combines direct heated steam, high pressure
and shredding to treat infectious materials.
The contaminated waste is loaded into the upper stainless
steel chamber where a heavy-duty shredder reduces the
waste into small pieces.
Using gravity, the processed material falls into the
treatment chamber, where every particle is steam
heated to 138°C (280 F) and pressurized to 3.8 bar
(55 psi) for 10 minutes. The operating conditions are
continuously monitored and validated to achieve complete
sterilization.
After the cooling process, the final product is
APPROVED BY THE HIGHER COUNCIL volume-reduced (by up to 80%), unrecognizable and
OF PUBLIC HEALTH OF FRANCE, safe to dispose of as ordinary municipal waste.
UNDER THE SUPERVISION OF THE
The 30 minutes average duration process cycle is totally
MINISTRY OF HEALTH AND THE automated. A computerized system monitors the process
MINISTRY OF THE ENVIRONMENT. and automatically prints a report with the essential
sterilizing parameters at the end of the cycle for
accurate record keeping.
ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT
ASME
6. T 150 > PROCESS VOLUME CAPACITY
150 Liters per Cycle
> TECHNICAL SPECIFICATIONS
General Characteristics
- Dimensions (L x W x H). cm 210 x 220 x 275
- Dimensions (L x W x H). ft 6.9 x 7.2 x 9
- Shipping Weight. kg 800
- Max Weight when filled with water.
1100
For a special hydraulic test. kg
- Stress. kg/cm2 1
- Steam Pressure. Bar 8
275
750
23334
- Max Steam Flow. kg/h 65
- Compressed Air. Bar 6
- Electricity 380 V / 3-Phase 8 kW
Operating Characteristics
- Average Cycle Time. minutes 30
- Process Volume Capacity. liters 150
- Average Waste Density. kg/m3 100 -150
110
- Average Process Weight Capacity. kg/Cycle 15 - 23
0
22
- Average Process Weight Capacity. lb/Cycle 33 - 51
210
- Microbial Inactivation 8 log 10
- Waste Volume Reduction 80%
Consumption / Cycle
- Steam. kg 9
- Electricity. kW/h 1.4
- Water. liters 15
Some of our customers :
Azerbaijan, Cameroon, France,
Gabon, Ghana, India, Iran,
Iraq, Kurdistan, Kuwait, Libya,
Panama, Russia, St Pierre et
Miquelon, Sudan, Turkey...
ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT
28 rue Sébastopol
59100 ROUBAIX -FRANCE
contact@ecodas.com
tél. +333 20 70 98 65 - fax +333 20 36 28 05
www.ecodas.com
7. T 300 > PROCESS VOLUME CAPACITY
350 Liters per Cycle
Our Solution,
Safety in One Step
Our patented process is designed to sterilize
medical waste, reduce its volume, and render
its components unrecognizable all in one
fully enclosed and automated system.
It combines direct heated steam, high pressure
and shredding to treat infectious materials.
The contaminated waste is loaded into the upper stainless
steel chamber where a heavy-duty shredder reduces the
waste into small pieces.
Using gravity, the processed material falls into the
treatment chamber, where every particle is steam
heated to 138°C (280 F) and pressurized to 3.8 bar
(55 psi) for 10 minutes. The operating conditions are
continuously monitored and validated to achieve complete
sterilization.
After the cooling process, the final product is
volume-reduced (by up to 80%), unrecognizable and
safe to dispose of as ordinary municipal waste.
The 30 minutes average duration process cycle is totally
automated. A computerized system monitors the process
APPROVED BY THE HIGHER COUNCIL and automatically prints a report with the essential
OF PUBLIC HEALTH OF FRANCE, sterilizing parameters at the end of the cycle for
UNDER THE SUPERVISION OF THE accurate record keeping.
MINISTRY OF HEALTH AND THE
MINISTRY OF THE ENVIRONMENT.
ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT
ASME
8. T 300 > PROCESS VOLUME CAPACITY
350 Liters per Cycle
> TECHNICAL SPECIFICATIONS
General Characteristics
- Dimensions (L x W x H). cm 220x 250 x 330
- Dimensions (L x W x H). ft 7.2 x 8.2 x 10.8
- Shipping Weight. kg 2000
- Max Weight when filled with water.
3100
For a special hydraulic test. kg
- Stress. kg/cm2 2
- Steam Pressure. Bar 8
- Max Steam Flow. kg/h 170
330
- Compressed Air. Bar 6
- Electricity 380 V / 3-Phase Surge Protection System 14 kW
Operating Characteristics
- Average Cycle Time. minutes 30
- Process Volume Capacity. liters 350
- Average Waste Density. kg/m3 100 -150
- Average Process Weight Capacity. kg/Cycle 35 - 52
- Average Process Weight Capacity. lb/Cycle 77 - 115
116
116
- Microbial Inactivation 8 log10
0
25
- Waste Volume Reduction 80%
220
220
Consumption / Cycle
- Steam. kg 15
- Electricity. kW/h 1,7
- Water. liters 25
Some of our customers :
Albania, Algeria, Bosnia, Cyprus,
Egypt, France, French Guyana,
French Polynesia, Iran, Ivory
Cost, Japan, Jordan, Kosovo,
Kuwait, Latvia, Lebanon, Libya,
ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT Mauritania, Mayotte, Mexico,
Morocco, Panama, Poland,
28 rue Sébastopol Reunion Island, Romania,
59100 ROUBAIX -FRANCE Russia, Slovakia, Syria,
Tunisia, Turkey, Ukraine, UAE,
contact@ecodas.com Venezuela...
tél. +333 20 70 98 65 - fax +333 20 36 28 05
www.ecodas.com
9. > PROCESS VOLUME CAPACITY
T 1000 1100 Liters per Cycle
Our Solution,
Safety in One Step
Our patented process is designed to sterilize
medical waste, reduce its volume, and render
its components unrecognizable all in one
fully enclosed and automated system.
It combines direct heated steam, high pressure
and shredding to treat infectious materials.
The contaminated waste is loaded into the upper stainless
steel chamber where a heavy-duty shredder reduces the
waste into small pieces.
Using gravity, the processed material falls into the
treatment chamber, where every particle is steam
heated to 138°C (280 F) and pressurized to 3.8 bar
(55 psi) for 10 minutes. The operating conditions are
continuously monitored and validated to achieve complete
sterilization.
After the cooling process, the final product is
volume-reduced (by up to 80%), unrecognizable and
safe to dispose of as ordinary municipal waste.
The 35 minutes average duration process cycle is totally
automated. A computerized system monitors the process
and automatically prints a report with the essential
sterilizing parameters at the end of the cycle for
accurate record keeping.
APPROVED BY THE HIGHER COUNCIL
OF PUBLIC HEALTH OF FRANCE,
UNDER THE SUPERVISION OF THE
MINISTRY OF HEALTH AND THE
MINISTRY OF THE ENVIRONMENT.
ASME
ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT
10. T 1000 > PROCESS VOLUME CAPACITY
1100 Liters per Cycle
> TECHNICAL SPECIFICATIONS
General Characteristics
- Dimensions (L x W x H). cm 600 x 440 x 633
- Dimensions (L x W x H). ft 19.7 x 14.4 x 21
- Shipping Weight. kg 2800
- Max Weight when filled with water.
5000
For a special hydraulic test. kg
- Stress. kg/cm2 2.5
- Steam Pressure. Bar 8
- Max Steam Flow. kg/h 370
633
- Compressed Air. Bar
633
6
- Electricity 380 V / 3-Phase Surge Protection System 20 kW
Operating Characteristics
455
455
- Average Cycle Time. minutes 35
360
360
- Process Volume Capacity. liters 1100
- Average Waste Density. kg/m3 100 - 150
- Average Process Weight Capacity. kg/Cycle 110 - 165
- Average Process Weight Capacity. lb/Cycle 242 - 364
- Microbial Inactivation 8 log 10
0
600 440
44 - Waste Volume Reduction 80 %
Consumption / Cycle
- Steam. kg 20
- Electricity. kW/h 4
- Water. liters 35
Some of our customers :
Egypt, France, Greece, Guadeloupe, Hungary, India, Kuwait,
Lebanon, Nigeria, Reunion Island, Saint Lucia, Syria, Turkey...
ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT
28 rue Sébastopol
59100 ROUBAIX -FRANCE
contact@ecodas.com
tél. +333 20 70 98 65 - fax +333 20 36 28 05
www.ecodas.com
11. > PROCESS VOLUME CAPACITY
T 2000 2500 Liters per Cycle
Our Solution,
Safety in One Step
Our patented process is designed to sterilize
medical waste, reduce its volume, and render
its components unrecognizable all in one
fully enclosed and automated system.
It combines direct heated steam, high pressure
and shredding to treat infectious materials.
The contaminated waste is loaded into
the upper stainless steel chamber
where a heavy-duty shredder reduces
the waste into small pieces.
Using gravity, the processed material falls into the
treatment chamber, where every particle is steam
heated to 138°C (280 F) and pressurized to 3.8 bar
(55 psi) for 10 minutes. The operating conditions are
continuously monitored and validated to achieve complete
sterilization.
After the cooling process, the final
product is volume-reduced (by up
to 80%), unrecognizable and safe
to dispose of as ordinary municipal
waste.
The 45 minutes average duration process cycle is totally
automated. A computerized system monitors the process
and automatically prints a report with the essential
sterilizing parameters at the end of the cycle for
accurate record keeping.
APPROVED BY THE HIGHER COUNCIL
OF PUBLIC HEALTH OF FRANCE,
UNDER THE SUPERVISION OF THE
MINISTRY OF HEALTH AND THE
MINISTRY OF THE ENVIRONMENT.
ASME
ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT
12. > PROCESS VOLUME CAPACITY
T 2000 2500 Liters per Cycle
> TECHNICAL SPECIFICATIONS
General Characteristics
- Dimensions (L x W x H). cm 600 x 440x 633
- Dimensions (L x W x H). ft 19.7 x 14.4 x 21
- Shipping Weight. kg 5200
- Max Weight when filled with water.
10500
For a special hydraulic test. kg
- Stress. kg/cm2 3.5
- Steam Pressure. Bar 8
- Max Steam Flow. kg/h 500
- Compressed Air. Bar 6
- Electricity 380 V / 3-Phase Surge Protection System 35 kW
633
Operating Characteristics
- Average Cycle Time. minutes 45
- Process Volume Capacity. liters 2500
455
- Average Waste Density. kg/m3
360
100 - 150
- Average Process Weight Capacity. kg/Cycle 250 - 375
- Average Process Weight Capacity. lb/Cycle 550 - 825
- Microbial Inactivation 8 log 10
- Waste Volume Reduction 80 %
0
Consumption / Cycle
600 44
- Steam. kg 40
- Electricity. kW/h 9
- Water. liters 50
Some of our customers :
Argentina, Brazil, China, Denmark, Ecuador, Egypt, France,
French Guyana, Greece, Honduras, Jamaica, Mexico, New
Caledonia, Panama, Renion Island, Spain, Tunisia, Turkey,
Turkmenistan, United Kingdom, Venezuela...
ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT
28 rue Sébastopol
59100 ROUBAIX -FRANCE
contact@ecodas.com
tél. +333 20 70 98 65 - fax +333 20 36 28 05
www.ecodas.com