User Manual
Indoor: MSS-1c + Outdoor: MPT-HC/MPT-MC
9500 MPR-E
3DB 18782 AAAA
Issue 1
Rel. 2.2.0
October 2010
Status: RELEASED
All rights reserved.
Passing on and copying of this document,
use and communication of its contents is not permitted
without written authorization from Alcatel-Lucent.
3DB 18782 AAAA
Issue 1
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent.
All other trademarks are the property of their respective owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no
responsibility for inaccuracies contained herein.
Copyright © 2010 Alcatel-Lucent
User Manual
Table of Contents
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 1/308
TABLE OF CONTENTS
LIST OF FIGURES ......................................................................................................................... 5
LIST OF TABLES ........................................................................................................................... 9
PREFACE......................................................................................................................................... 11
Preliminary Information.............................................................................................................. 11
Applicability................................................................................................................................. 12
Scope ........................................................................................................................................... 12
History.......................................................................................................................................... 12
Change notes .............................................................................................................................. 13
Handbook Structure ................................................................................................................... 13
General on Alcatel-Lucent Customer Documentation ............................................................ 14
1 SAFETY, EMC, EMF, ESD NORMS AND EQUIPMENT LABELLING ........................................ 19
1.1 Declaration of conformity to CE marking and Countries List ......................................... 20
1.2 Specific label for MPR equipment...................................................................................... 21
1.3 Applicable standards and recommendations ................................................................... 21
1.4 Safety Rules ......................................................................................................................... 22
1.4.1 General Rules................................................................................................................. 22
1.4.2 Labels Indicating Danger, Forbiddance, Command........................................................ 23
1.5 Electromagnetic Compatibility (EMC norms).................................................................... 26
1.6 Equipment protection against electrostatic discharges .................................................. 27
1.7 Cautions to avoid equipment damage............................................................................... 28
2 PRODUCT INFORMATION AND PLANNING ............................................................................. 29
2.1 9500 Family overview .......................................................................................................... 31
2.1.1 9500 MPR System Family .............................................................................................. 35
2.1.2 Family elements described in this User Manual ............................................................. 36
2.1.3 MSS-1c ........................................................................................................................... 36
2.1.4 MPT-HC .......................................................................................................................... 37
2.1.5 MPT-MC.......................................................................................................................... 37
2.1.6 MSS-1c to MPT-HC interconnection............................................................................... 38
2.1.7 MSS-1c to MPT-MC interconnection............................................................................... 40
2.1.8 Antennas......................................................................................................................... 40
2.2 Radio capacity, channelling and modulation (MPT-HC/MPT-MC).................................... 41
2.3 Standard Features ............................................................................................................... 44
2.4 Radio Configurations .......................................................................................................... 44
2.5 Typical System Configurations .......................................................................................... 45
2.6 Environmental and Electrical Characteristics................................................................... 46
2.6.1 General characteristics (MSS-1c)................................................................................... 46
2.6.2 General characteristics (MPT-HC/MPT-MC)................................................................... 47
2.6.3 MPT-MC characteristics.................................................................................................. 48
2.6.4 MPT-HC characteristics .................................................................................................. 49
2.6.5 Radio performances ....................................................................................................... 49
2.6.6 General characteristics (Power Extractor) ...................................................................... 50
2.7 Parts Lists............................................................................................................................. 51
2.7.1 MSS-1c ........................................................................................................................... 51
2.7.2 MPT-HC optical interface option ..................................................................................... 51
2.7.3 MPT-HC with internal diplexer ........................................................................................ 52
2.7.4 MPT-MC with internal diplexer........................................................................................ 54
2.7.5 MPT-HC/MPT-MC with external diplexer (7/8 GHz)........................................................ 56
2.8 Functional description ........................................................................................................ 59
2.8.1 MSS-1c (Indoor Unit) ...................................................................................................... 59
User Manual
Table of Contents
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 12/308
2.8.2 Fan unit........................................................................................................................... 63
2.8.3 MPT-HC .......................................................................................................................... 64
2.8.4 Power Extractor .............................................................................................................. 73
2.8.5 MPT-MC.......................................................................................................................... 74
2.8.6 Radio Transmission Features with MPT-HC/MPT-MC.................................................... 75
2.8.7 TMN communication channels ....................................................................................... 78
2.8.8 Traffic profiles ................................................................................................................. 79
2.8.9 Ethernet Traffic Management ......................................................................................... 84
2.8.10 Quality Of Services (QoS) ............................................................................................ 85
2.8.11 Cross-connections ........................................................................................................ 89
2.8.12 Synchronization ............................................................................................................ 91
3 NE MANAGEMENT BY SOFTWARE APPLICATION................................................................. 95
3.1 WebEML start ....................................................................................................................... 95
3.2 Tool bar................................................................................................................................. 97
3.3 Alarm Synthesis................................................................................................................... 98
3.4 Domain Alarm Synthesis Area............................................................................................ 98
3.5 General Information on the Management State ................................................................ 99
3.6 Navigator area...................................................................................................................... 100
3.6.1 Commissioning ............................................................................................................... 101
3.6.2 Performance Monitoring ................................................................................................. 117
3.6.3 Troubleshooting .............................................................................................................. 126
3.6.4 Maintenance ................................................................................................................... 128
3.6.5 Monitoring ....................................................................................................................... 129
3.6.6 Provisioning Tool............................................................................................................. 135
4 INSTALLATION............................................................................................................................ 149
4.1 Installation & Interconnection overview ............................................................................ 149
4.2 Hardware Installation........................................................................................................... 151
4.2.1 Power consumption ........................................................................................................ 151
4.2.2 Rack Installation ............................................................................................................. 152
4.2.3 MSS-1c installation ......................................................................................................... 162
4.2.4 MPT-HC Installation........................................................................................................ 168
4.2.5 MPT-MC Installation........................................................................................................ 208
4.2.6 Power Extractor .............................................................................................................. 228
4.2.7 Indoor Installation ........................................................................................................... 229
4.2.8 Antenna Alignment ......................................................................................................... 237
4.3 Software local copy ............................................................................................................. 246
4.3.1 Getting Started................................................................................................................ 247
4.3.2 PC Characteristics .......................................................................................................... 247
4.3.3 Local copy of the Software Package (SWP) to the PC................................................... 248
4.3.4 Local copy the WebEML to PC....................................................................................... 250
4.3.5 Configure PC Network Card to Connect to NE............................................................... 256
5 PROVISIONING............................................................................................................................ 259
6 MAINTENANCE AND TROUBLE-CLEARING ............................................................................ 263
6.1 Introduction.......................................................................................................................... 263
6.2 Maintenance Philosophy..................................................................................................... 264
6.3 Personal Computer (PC)/Laptop ........................................................................................ 264
6.4 Troubleshooting................................................................................................................... 264
6.4.1 Before Going to Site Checklist........................................................................................ 264
6.4.2 PC Troubleshooting ........................................................................................................ 265
6.4.3 Troubleshooting Basics................................................................................................... 265
6.4.4 Troubleshooting with MSS-1c electrical or optical connection........................................ 271
User Manual
Table of Contents
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 3/308
6.4.5 Troubleshooting Path Problems...................................................................................... 271
6.4.6 Troubleshooting Configuration Problems........................................................................ 273
6.4.7 Troubleshooting Ethernet Problems ............................................................................... 273
6.4.8 Troubleshooting TMN Problems ..................................................................................... 274
6.5 Failed equipment removal and replacement..................................................................... 276
6.5.1 MSS-1c removal and replacement ................................................................................. 276
6.5.2 MPT-HC removal and replacement................................................................................. 276
6.5.3 MPT-MC removal and replacement ................................................................................ 276
6.6 Cleaning................................................................................................................................ 277
7 LINE–UP AND COMMISSIONING............................................................................................... 279
7.1 Introduction.......................................................................................................................... 280
7.1.1 General ........................................................................................................................... 280
7.1.2 Safety–EMC–EMF–ESD norms and cautions to avoid equipment damage................... 281
7.1.3 Conventions.................................................................................................................... 281
7.1.4 Summary of the line–up, commissioning, and acceptance phases ................................ 282
7.1.5 How to access the remote NE ........................................................................................ 283
7.2 Commissioning of STATION A – phase 1 (Turn up).......................................................... 284
7.2.1 Turn–on preliminary operations ...................................................................................... 284
7.2.2 Powering up the MSS-1c(s) with ODU(s) connected...................................................... 285
7.3 Commissioning of STATION B – phase 1 (Turn up).......................................................... 285
7.4 Fine antenna alignment and preliminary checks – Stations A & B................................. 285
7.4.1 Fine antenna alignment .................................................................................................. 285
7.4.2 Preliminary checks.......................................................................................................... 286
7.5 End of commissioning phase 1 (Turn up) in STATION A ................................................. 287
7.6 Commissioning station A – phase 2 (acceptance test).................................................... 288
7.6.1 Installation and cabling visual inspection........................................................................ 290
7.6.2 System configuration ...................................................................................................... 290
7.6.3 E1 traffic.......................................................................................................................... 292
7.6.4 Ethernet traffic................................................................................................................. 293
7.6.5 NE configuration ............................................................................................................. 293
7.6.6 Data/Time settings .......................................................................................................... 294
7.6.7 Hop E1 stability test ........................................................................................................ 294
7.6.8 Ethernet Traffic stability test............................................................................................ 295
7.7 Commissioning station B – Phase 2 (acceptance Test)................................................... 299
7.8 Final operations ................................................................................................................... 299
7.9 Annex A: fine antenna alignment....................................................................................... 299
ABBREVIATIONS ............................................................................................................................ 301
CUSTOMER DOCUMENTATION FEEDBACK.............................................................................. 307
User Manual
Table of Contents
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 14/308
User Manual
List of Figures
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 5/308
LIST OF FIGURES
Figure 1. Multiservice Aggregation Layer ......................................................................................... 33
Figure 2. Service Awareness ............................................................................................................ 33
Figure 3. Packet Node ...................................................................................................................... 34
Figure 4. Service-driven Packet Adaptive Modulation ...................................................................... 34
Figure 5. 9500 MPR System Family ................................................................................................. 35
Figure 6. MPT-HC ............................................................................................................................. 37
Figure 7. MPT-MC............................................................................................................................. 37
Figure 8. MPT-HC connection (electrical cable) ............................................................................... 38
Figure 9. MPT-HC connection (optical cable + power supply cable to MSS-1c)............................... 39
Figure 10. MPT-HC connection (optical cable + power supply cable to Station battery) .................. 39
Figure 11. MPT-MC connection......................................................................................................... 40
Figure 12. TDM Over Ethernet Packet Node - Mapping of 10 E1 TDM on Ethernet ........................ 45
Figure 13. TDM and Ethernet Terminal Packet Transport 10 E1 TDM and 1 Radio Direction.......... 45
Figure 14. MSS-1c block diagram..................................................................................................... 59
Figure 15. MSS-1c front view............................................................................................................ 60
Figure 16. MSS-1c rear view ............................................................................................................ 60
Figure 17. MSS-1c and Fan unit....................................................................................................... 63
Figure 18. MPT system..................................................................................................................... 65
Figure 19. 11-38 GHz MPT-HC housing ........................................................................................... 65
Figure 20. 6 GHz MPT-HC housing .................................................................................................. 65
Figure 21. 7-8 GHz MPT-HC housing ............................................................................................... 66
Figure 22. MPT-HC block diagram.................................................................................................... 66
Figure 23. 7/8 GHz MPT-HC architecture ......................................................................................... 69
Figure 24. 11 to 38 GHz MPT-HC architecture ................................................................................. 69
Figure 25. Power Extractor ............................................................................................................... 73
Figure 26. 6 GHz and from 11 to 38 GHz MPT-MC housing............................................................. 74
Figure 27. 7-8 GHz MPT-MC housing............................................................................................... 75
Figure 28. Available loopbacks ......................................................................................................... 77
Figure 29. Traffic profiles .................................................................................................................. 79
Figure 30. Traffic profiles .................................................................................................................. 80
Figure 31. E1 Traffic.......................................................................................................................... 81
Figure 32. E1 Traffic.......................................................................................................................... 82
Figure 33. E1 Traffic.......................................................................................................................... 83
Figure 34. QoS in the MSS-1c.......................................................................................................... 85
Figure 35. QoS in the MPT ............................................................................................................... 87
Figure 36. Cross-connection............................................................................................................. 89
Figure 37. E1 from/to Radio port....................................................................................................... 89
Figure 38. E1 from/to Ethernet port .................................................................................................. 90
Figure 39. Main view: System Overview........................................................................................... 97
Figure 40. Inventory.......................................................................................................................... 101
Figure 41. Software Download: Software Package versions ............................................................ 102
Figure 42. Software download .......................................................................................................... 103
Figure 43. Software Download: Active Software Package summary................................................ 103
Figure 44. Software Download: Stand-by Software Package summary............................................ 104
Figure 45. Date/Time Configuration.................................................................................................. 105
Figure 46. Site Information................................................................................................................ 106
Figure 47. Protection Configuration .................................................................................................. 106
Figure 48. Radio Configuration: FCM - RTPC .................................................................................. 109
Figure 49. Radio Configuration: FCM - ATPC................................................................................... 109
Figure 50. Radio Configuration: ACM - RTPC .................................................................................. 110
Figure 51. Advanced Radio Configuration........................................................................................ 110
Figure 52. MSS-1c Configuration...................................................................................................... 111
User Manual
List of Figures
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 16/308
Figure 53. FTP Server Parameters................................................................................................... 112
Figure 54. Network Interfaces........................................................................................................... 113
Figure 55. Static Routing................................................................................................................... 114
Figure 56. Trusted SNMP Managers ................................................................................................ 115
Figure 57. Manager registration........................................................................................................ 115
Figure 58. Backup / Restore ............................................................................................................. 116
Figure 59. Performance History File Upload..................................................................................... 118
Figure 60. Counter Thresholds ......................................................................................................... 118
Figure 61. 15Min Counter activation................................................................................................. 119
Figure 62. 15Min Counter ................................................................................................................. 119
Figure 63. 15Min Counter history...................................................................................................... 120
Figure 64. 15Min Counter deactivation............................................................................................. 120
Figure 65. Adaptive Modulation counter activation........................................................................... 121
Figure 66. 15Min Counter ................................................................................................................. 122
Figure 67. 15Min Counter history...................................................................................................... 122
Figure 68. 15Min Counter deactivation............................................................................................. 123
Figure 69. Ethernet: Qos Counters................................................................................................... 124
Figure 70. Qos Counters example for Aggregate ............................................................................. 125
Figure 71. Inventory.......................................................................................................................... 126
Figure 72. Loopback activation......................................................................................................... 127
Figure 73. ACM Manual Management.............................................................................................. 127
Figure 74. Maintenance .................................................................................................................... 128
Figure 75. Alarms.............................................................................................................................. 130
Figure 76. Power measurements...................................................................................................... 130
Figure 77. Power measurements...................................................................................................... 131
Figure 78. Modem measurements .................................................................................................... 132
Figure 79. Modem measurements .................................................................................................... 133
Figure 80. Events.............................................................................................................................. 134
Figure 81. Provisioning Tool: Welcome screen................................................................................. 135
Figure 82. Ethernet ports provisioning .............................................................................................. 136
Figure 83. Cross connection TDM2TDM .......................................................................................... 138
Figure 84. One shot tributaries configuration.................................................................................... 138
Figure 85. Cross connection functional scheme............................................................................... 139
Figure 86. Cross connection to user Ethernet port ........................................................................... 140
Figure 87. Cross connection functional scheme............................................................................... 141
Figure 88. Management port provisioning ........................................................................................ 142
Figure 89. TDM cross connection between radio and Ethernet port................................................. 143
Figure 90. Cross connection functional scheme............................................................................... 144
Figure 91. Network Synchronization Clock provisioning................................................................... 144
Figure 92. NE bridge mode selection................................................................................................ 145
Figure 93. Port VLAN provisioning.................................................................................................... 146
Figure 94. Station interconnections with MPT-MC ............................................................................ 149
Figure 95. Station interconnections with MPT-HC with Power Extractor........................................... 149
Figure 96. Station interconnections with MPT-HC (optical cable +
coax. power supply cable to MSS-1c)............................................................................................... 150
Figure 97. Station interconnections with MPT-HC (optical cable +
coax. power supply cable to Station battery) .................................................................................... 150
Figure 98. Fixing the Rack to Floor (1) ............................................................................................. 153
Figure 99. Fixing the Rack to Floor (2) ............................................................................................. 154
Figure 100. Floor file drilling template............................................................................................... 155
Figure 101. Example of securing rack assembly to computer floor .................................................. 156
Figure 102. Laborack........................................................................................................................ 157
Figure 103. Top Rack Unit (T.R.U.)................................................................................................... 158
Figure 104. Top Rack Unit - Front/Rear............................................................................................ 158
User Manual
List of Figures
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 7/308
Figure 105. Top Rack Unit - Fixed to rack......................................................................................... 158
Figure 106. TRU Connections .......................................................................................................... 160
Figure 107. TRU Grounding position on Laborack ........................................................................... 160
Figure 108. ETSI Rack - Ground connection.................................................................................... 161
Figure 109. Laborack - Ground connection ...................................................................................... 161
Figure 110. Grounding ...................................................................................................................... 163
Figure 111. Grounding....................................................................................................................... 163
Figure 112. Power supply connector................................................................................................. 163
Figure 113. Installation solution......................................................................................................... 164
Figure 114. Installation solution......................................................................................................... 164
Figure 115. Installation solution......................................................................................................... 165
Figure 116. Interconnections to connector support 1.6/5.6 75 ohm Panel 1U (3CC08061AAAA).... 165
Figure 117. Interconnections to connector support BNC 75 ohm Panel 1U (3CC08061ABAA) ....... 166
Figure 118. Interconnections to support 19 Inch modules 120 ohm Panel 3U (3CC07810AAAA) ... 166
Figure 119. ....................................................................................................................................... 167
Figure 120. ....................................................................................................................................... 167
Figure 121. Views of MPT-HC with embedded diplexer (11-38 GHz) ............................................... 169
Figure 122. Views of MPT-HC with embedded diplexer (6 GHz)...................................................... 170
Figure 123. Views of MPT-HC with external diplexer (7 GHz and 8 GHz)........................................ 170
Figure 124. Views of MPT-HC with embedded diplexer (11-38 GHz) ............................................... 172
Figure 125. Views of MPT-HC with external diplexer (7 GHz and 8 GHz)........................................ 173
Figure 126. Views of MPT-HC with embedded diplexer (6 GHz)...................................................... 174
Figure 127. Composition of MPT-HC with external diplexer ............................................................. 175
Figure 128. MPT-HC TRANSCEIVER and BRANCHING boxes coupling surfaces ......................... 176
Figure 129. 6-7-8 GHz MPT-HC BRANCHING box mistake-proofing............................................... 176
Figure 130. Label affixed on the MPT-HC and MPT-HC TRANSCEIVER box.................................. 177
Figure 131. Label affixed inside the MPT-HC BRANCHING box...................................................... 178
Figure 132. Example of integrated antenna Pole Mounting
(with antenna and nose adapter) ...................................................................................................... 181
Figure 133. "Pole Mounting for Remote ODU" Installation kit (3DB10137AAXX)............................ 182
Figure 134. Example of antenna polarization change (“1+0” MPT-HC integrated antenna)............. 183
Figure 135. Putting silicone grease on O-ring before MPT-HC insertion .......................................... 184
Figure 136. MPT-HC 1+0 installation for integrated antenna (11-38 GHz) ....................................... 184
Figure 137. MPT-HC 1+0 installation for integrated antenna (6-7-8 GHz: vertical polarization) ....... 185
Figure 138. MPT-HC 1+0 installation for integrated antenna (6-7-8 GHz: horizontal polarization)... 185
Figure 139. "Pole Mounting for Remote ODU" installation................................................................ 186
Figure 140. Putting silicone grease on O-ring before MPT-HC insertion .......................................... 186
Figure 141. MPT-HC 1+0 installation for not integrated antenna (11-38 GHz with pole mounting
P/N 3DB 10137 AAAB) ..................................................................................................................... 187
Figure 142. MPT-HC 1+0 installation for not integrated antenna (6-7-8 GHz with pole mounting
P/N 3DB10137AAXX) ....................................................................................................................... 187
Figure 143. Locations for Cable Grounds......................................................................................... 204
Figure 144. Views of MPT-MC with embedded diplexer (6 and 11-38 GHz)..................................... 209
Figure 145. Views of MPT-MC with external diplexer (7 GHz and 8 GHz)........................................ 210
Figure 146. Views of MPT-MC with embedded diplexer (6 and 11-38 GHz)..................................... 211
Figure 147. Views of MPT-MC with external diplexer (7 GHz and 8 GHz)........................................ 211
Figure 148. Composition of MPT-MC with external diplexer............................................................. 212
Figure 149. MPT-MC TRANSCEIVER and BRANCHING boxes coupling surfaces......................... 213
Figure 150. 7-8 GHz MPT-MC BRANCHING box mistake-proofing ................................................. 214
Figure 151. Label affixed on the MPT-MC and MPT-MC TRANSCEIVER box................................. 215
Figure 152. Label affixed inside the MPT-MC BRANCHING box...................................................... 216
Figure 153. Example of antenna polarization change (“1+0” MPT-MC integrated antenna)............. 219
Figure 154. Putting silicone grease on O-ring before MPT-MC insertion.......................................... 220
Figure 155. MPT-MC 1+0 installation for integrated antenna (6 GHz and 11-38 GHz)..................... 220
User Manual
List of Figures
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 18/308
Figure 156. MPT-MC 1+0 installation for integrated antenna (7-8 GHz: vertical polarization).......... 221
Figure 157. MPT-MC 1+0 installation for integrated antenna (7-8 GHz: horizontal polarization)...... 221
Figure 158. "Pole Mounting for Remote ODU" installation................................................................ 222
Figure 159. Putting silicone grease on O-ring before MPT-MC insertion.......................................... 222
Figure 160. MPT-MC 1+0 installation for not integrated antenna (with pole mounting
P/N 3DB 10137 AAAB) ..................................................................................................................... 223
Figure 161. Short kit plug R2CT ....................................................................................................... 224
Figure 162. Short kit plug R2CT items.............................................................................................. 224
Figure 163. MPT/AWY Service Cord ................................................................................................ 239
Figure 164. Checking Feedhead Flange with a Spirit level............................................................... 242
Figure 165. Indicative head-on signal pattern for a parabolic antenna ............................................. 244
Figure 166. Example Tracking Path Signals..................................................................................... 245
Figure 167. Example Tracking Path Signals on the First Side Lobe................................................. 245
Figure 168. PC connection ............................................................................................................... 259
Figure 169. Relative positions of stations A and B ........................................................................... 281
Figure 170. Test bench for tributary functionality check with MPT-HC/MPT-MC............................... 292
Figure 171. Test bench for tributary functionality check with MPT-HC/MPT-MC............................... 294
Figure 172. Test bench for optional Ethernet Data Channel functionality with 1 additional PC and 1
Ethernet cable................................................................................................................................... 296
Figure 173. Test bench for optional Ethernet Data Channel functionality with 2 additional PCs ..... 297
Figure 174. Test bench for optional Ethernet Data Channel functionality with
2 Ethernet Data Analyzers ................................................................................................................ 298
User Manual
List of Tables
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 9/308
LIST OF TABLES
Table 1. Radio capacity, channelling scheme and modulation (Static Modulation)........................... 41
Table 2. Radio capacity, channelling scheme and modulation (Adaptive Modulation)...................... 43
Table 3. MSS-1c item codes ............................................................................................................. 51
Table 4. CD-ROM Software codes.................................................................................................... 51
Table 5. MPT-HC option.................................................................................................................... 51
Table 6. MPT-HC codes with internal diplexer .................................................................................. 52
Table 7. MPT-MC codes with internal diplexer.................................................................................. 54
Table 8. 7 GHz MPT-MC codes with external diplexer...................................................................... 56
Table 9. 7 GHz MPT-HC codes with external diplexer ...................................................................... 56
Table 10. 7 GHz Branching assemblies (for MPT-HC and MPT-MC)................................................ 57
Table 11. 8 GHz MPT-MC codes with external diplexer.................................................................... 58
Table 12. 8 GHz MPT-HC codes with external diplexer .................................................................... 58
Table 13. 8 GHz Branching assemblies (for MPT-HC and MPT-MC)................................................ 58
Table 14. RSSI Table ........................................................................................................................ 72
Table 15. Waveguide Flange Data.................................................................................................... 72
Table 16. MPT-HC external interfaces ............................................................................................. 171
Table 17. RF interface...................................................................................................................... 171
Table 18. MPT-HC Output flanges with external antenna ................................................................. 201
Table 19. 6-7-8GHz Flextwist waveguide.......................................................................................... 202
Table 20. 11-38GHz Flextwist waveguide ......................................................................................... 202
Table 21. MPT-MC external interfaces............................................................................................. 210
Table 22. RF interface...................................................................................................................... 210
Table 23. Pin Function: Tributaries 1- 8 ............................................................................................ 235
Table 24. Pin Function: Tributaries 9- 10 .......................................................................................... 236
Table 25. MSS-1c and Fans Alarm Matrix ........................................................................................ 266
Table 26. MPT-HC Alarm Matrix ....................................................................................................... 267
Table 27. MPT-MC Alarm Matrix ....................................................................................................... 269
Table 28. TMN Network Troubleshooting ........................................................................................ 274
Table 29. Test and commissioning instruments ................................................................................ 280
User Manual
List of Tables
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 110/308
User Manual
Preface
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 11/308
PREFACE
Preliminary Information
WARRANTY
Any warranty must be referred exclusively to the terms of the contract of sale of the equipment to
which this handbook refers to.
Alcatel–Lucent makes no warranty of any kind with regards to this manual, and specifically disclaims
the implied warranties of merchantability and fitness for a particular purpose. Alcatel–Lucent will not
be liable for errors contained herein or for damages, whether direct, indirect, consequential, inci-
dental, or special, in connection with the furnishing, performance, or use of this material.
INFORMATION
The product specification and/or performance levels contained in this document are for information
purposes only and are subject to change without notice. They do not represent any obligation on the
part of Alcatel–Lucent.
COPYRIGHT NOTIFICATION
The technical information of this manual is the property of Alcatel–Lucent and must not be copied,
reproduced or disclosed to a third party without written consent.
SAFETY RECOMMENDATIONS
The safety recommendations here below must be considered to avoid injuries on persons and/or
damage to the equipment:
1) Service Personnel
Installation and service must be carried out by authorized persons having appropriate technical
training and experience necessary to be aware of hazardous operations during installation and
service, so as to prevent any personal injury or danger to other persons, as well as prevent-
damaging the equipment.
2) Access to the Equipment
Access to the Equipment in use must be restricted to Service Personnel only.
3) Safety Rules
Recommended safety rules are indicated in Chapter 1 from page 19.
User Manual
Preface
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 112/308
Local safety regulations must be used if mandatory. Safety instructions in this handbook should
be used in addition to the local safety regulations. In case of conflict between safety instructions
stated in this manual and those indicated in local regulations, mandatory local norms will pre-
vail. Should not local regulations be mandatory, then safety rules stated in this manual will pre-
vail.
SERVICE PERSONNEL SKILL
Service Personnel must have an adequate technical background on telecommunications and in par-
ticular on the equipment subject of this handbook.
An adequate background is required to properly install, operate and maintain equipment. The fact
of merely reading this handbook is considered as not enough.
Applicability
This handbook applies to the following product–release:
PRODUCT
9500 MPR-E
PRODUCT RELEASE
MSS-1c/MPT-HC/MPT-MC 2.2.0
Scope
This document aims to describe the hardware and software functionalities of the 9500 MPR MPT-Access.
This document is intended to the technicians involved in Planning, in Operation and Maintenance and in
Commissioning of the 9500 MPR MPT-Access.
History
ISSUE DATE DESCRIPTIONS
01 October 2010
User Manual
Preface
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 13/308
Change notes
Handbook Structure
This handbook has been edited according to the Alcatel-Lucent standardized “drawing-up guides" com-
plying with such suggestion.
This handbook is divided into the main topics described in the table of contents:
PREFACE It contains general information as preliminary information, hand-
book scope, history. Furthermore, it describes the handbook struc-
ture and the customer documentation.
SAFETY This section includes all the safety instructions.
PRODUCT INFORMATION
AND PLANNING
This section provides the equipment description (at system, MSS-
1c and Outdoor levels), introduces the basic information regarding
the HW architecture, and gives its technical characteristics.
NE MANAGEMENT BY
SOFTWARE APPLICATIONS
This section gives the description and use of the SW tools available
for the NE management.
INSTALLATION This section provides whole information regarding Equipment hard-
ware installation.
Moreover, it contains the whole operative information on:
– provisioning of equipment items (P/Ns, equipping rules)
– their physical position in the system
– unit assembly and front panel drawings, with the description
on the access point usage (connectors, visual indicators, but-
tons).
This section provides also the whole operative instructions for the
preparation of the Craft Terminal for the Line–Up and Commission-
ing of the two NEs making up the radio link.
PROVISIONING This section gives all the instructions to provision (to configure) the
NE.
MAINTENANCE AND
TROUBLE-CLEARING
This section contains the whole logical and operative information for
the equipment maintenance and system upgrade.
LINE-UP AND
COMMISSIONING
This section provides all the instructions for the line-up and com-
missioning of the NE.
ABBREVIATIONS The abbreviation list is supplied.
CUSTOMER DOCUMENTA-
TION FEEDBACK
It contains info regarding customer opinions collection about this
documentation.
User Manual
Preface
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 114/308
General on Alcatel-Lucent Customer Documentation
This paragraph describes in general the Alcatel–Lucent Customer Documentation system, details the
association between the product levels and the associated documentation, and explains Customer Doc-
umentation characteristics as well as the policies for its delivery and updating.
Customer–Independent Standard Customer Documentation
a) Definition
Standard Customer Documentation, referred to hereafter, must be always meant as plant–indepen-
dent and is always independent of any Customization.
Plant–dependent and/or Customized documentation, if envisaged by the contract, is subjected to
commercial criteria as far as contents, formats and supply conditions are concerned.
N.B. Plant–dependent and Customized documentation is not described here.
b) Aims of standard Customer Documentation
Standard system, hardware and software documentation is meant to give the Customer personnel
the possibility and the information necessary for installing, commissioning, operating, and maintain-
ing the equipment according to Alcatel–Lucent Laboratory design and Installation Dept. choices. In
particular:
• the contents of the chapters associated to the software applications focus on the explanation
of the man–machine interface and of the operating procedures allowed by it;
• maintenance is described down to faulty PCB location and replacement.
N.B. No supply to Customers of design documentation (like PCB hardware design andproduction
documents and files, software source programs, programming tools, etc.) is envisaged.
Product levels and associated Customer Documentation
a) Products
A “product” is defined by the network hierarchical level where it can be inserted and by the whole
of performances and services that it is meant for.
E.g. 9500 MPR is a product.
b) Product-releases
A ”product” evolves through successive “product–releases”, which are the real products marketed
for their delivery at a certain ”product–release” availability date. A certain ”product–release” performs
more functionalities than the previous one.
E.g. Rel.1.0 and Rel.2.0 are two successive “product–releases” of the same “product”.
A “product–release” comprehends a set of hardware components and at least one “Software Pack-
age” (SWP); as a whole, they identify the possible network applications and the equipment perfor-
mances that the specific “product–release” has been designed, engineered, and marketed for.
c) Configurations and Network Elements
In some cases, a “product–release” includes different possible “configurations” which are distin-
guished from one another by different “Network Element” (NE) types and, from the management
point of view, by different SWPs.
d) SWP releases, versions, and CD–ROMs
• Each SWP is distributed by means of a specific SWP CD–ROM.
• A SWP is identified by its “Denomination”, “P/N” (Part Number) and “CS” (Change Status), that
are printed on the CD–ROM’s label:
– the first and second digits of the “Denomination” (e.g. 2.0) correspond to the “HW product–
release” number;
– the third digit of the of the “Denomination” (e.g. 2.0.2) identifies the Version Level of the
SWP.
User Manual
Preface
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 15/308
• A SWP with new Version Level, providing main features in addition to those of the previous Ver-
sion Level SWP, is distributed by means of a SWP CD–ROM having new “Denomination”,“P/
N” (Part Number), and “CS” restarting from 01
• A SWP patch version, if any, is created to correct SW bugs, and/or to add minor features, andis
distributed by means of a SWP CD–ROM, that can be identified:
– by the same “P/N” of the former CD–ROM, but with an incremented “CS” number
(e.g.CS=02 instead of previous CS=01)
– or by a new “P/N”, and “CS” restarting from 01.
Handbook Updating
The handbooks associated to the "product-release" are listed in “History“ on page 12.
Each handbook is identified by:
– the name of the "product–release" (and "version" when the handbook is applicable to the versions
starting from it, but not to the previous ones),
– the handbook name,
– the handbook Part Number,
– the handbook edition (usually first edition=01),
– the handbook issue date. The date on the handbook does not refer to the date of print but to the date
on which the handbook source file has been completed and released for the production.
Changes introduced in the same product–release (same handbook P/N)
The edition and date of issue might change on future handbook versions for the following reasons:
– only the date changes (pointed out in the Table of Contents) when modifications are made to the edi-
torial system not changing the technical contents of the handbook.
– the edition, hence the date, is changed because modifications made concern technical contents. In
this case:
• the changes with respect to the previous edition are listed in “History” on page 12;
• in affected chapters, revision bars on the left of the page indicate modifications in text and draw-
ings.
Changes concerning the technical contents of the handbook cause the edition number increase (e.g. from
Ed.01 to Ed.02). Slight changes (e.g. for corrections) maintain the same edition but with the addition of
a version character (e.g. from Ed.02 to Ed.02A). Version character can be used for draft or proposal edi-
tions.
NOTES FOR HANDBOOKS RELEVANT TO SOFTWARE APPLICATIONS
Handbooks relevant to software applications (typically the Operator's Handbooks)
are not modified unless the new software "version" distributed to Customers
implies man-machine interface changes or in case of slight modifications not
affecting the understanding of the explained procedures.
Moreover, should the screen prints included in the handbook contain the product–release's
"version" marking, they are not replaced in the handbooks related to a subsequent version, if
the screen contents are unchanged.
Supplying updated handbooks to Customers
Supplying updated handbooks to Customers who have already received previous issues is submitted to
commercial criteria.
By updated handbook delivery it is meant the supply of a complete copy of the handbook new issue (sup-
plying errata-corrige sheets is not envisaged).
User Manual
Preface
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 116/308
Changes due to new product version
A new product version changes the handbook P/N and the edition starts from 01.
In this case the modified parts of the handbook are not listed.
Customer documentation on CD-ROM
In the following by 'CD-ROM' it is meant 'Customer Documentation on CD-ROM'
Contents, creation and production of a CD-ROM
In most cases, a CD-ROM contains in read-only eletronic format the documentation of one product-
release(-version) and for a certain language.
In some other cases, the same CD-ROM can contain the documentation of different product-release(-ver-
sion)s for a certain language.
As a general rule:
– CD-ROMs for Network Management products do not contain:
• the Installation Guides
• the documentation of system optional features that Customers could not buy from Alcatel-
Lucent together with the main applicative SW.
– CD-ROMs for Network Elements products do not contain:
• the documentation of system optional features (e.g. System Installation Handbooks related to
racks that Customers could not buy from Alcatel-Lucent together with the main equipment).
A CD-ROM is obtained collecting various handbooks and documents in .pdf format. Bookmarks and
hyperlinks make the navigation easier. No additional information is added to each handbook, so that the
documentation present in the CD-ROMs is exactly the same the Customer would receive on paper.
The files processed in this way are added to files/images for managing purpose and a master CD-ROM
is recorded.
Suitable checks are made in order to have a virus-free product.
After a complete functional check, the CD-ROM image is electronically transferred to the archive of the
Production Department, so that the CD-ROM can be produced and delivered to Customers.
Use of the CD-ROM
The CD-ROM can be used both in PC and Unix WS environments.
The CD-ROM starts automatically with autorun and hyperlinks from the opened “Index" document permit
to visualize the .pdf handbooks
Other hyperlinks permit to get, from the Technical handbooks, the specific .pdf setting documents.
In order to open the .pdf documents Adobe Acrobat Reader Version 4.0 (minimum) must have been
installed on the platform.
The CD-ROM doesn't contain the Adobe Acrobat Reader program. The Customer is in charge of getting
and installing it.
ReadMe info is present on the CD-ROM to this purpose.
Then the Customer is allowed to read the handbooks on the PC/WS screen, using the navigation and
zooming tools included in the tool, and to print selected parts of the documentation through a local printer.
User Manual
Preface
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 17/308
CD-ROM identification
Each CD-ROM is identified:
1) by external identifiers, that are printed on the CD-ROM upper surface:
– the name of the "product-release(s)" (and "version" if applicable)
– a writing indicating the language(s),
– the CD-ROM Part Number),
– the CD-ROM edition (usually first edition=01)
2) and, internally, by the list of the source handbooks and documents (P/Ns and editions) by
whose collection and processing the CD-ROM itself has been created.
CD-ROM updating
The list of source handbook/document P/Ns-editions indicated in previous para. point 2) , in association
with the CD-ROM's own P/N-edition, is also loaded in the Alcatel-Information-System as a structured list.
Whenever a new edition of any of such handbooks/documents is released in the Alcatel-Lucent archive
system, a check in the Alcatel-Information-System is made to identify the list of CD-ROMs that must be
updated to include the new editions of these handbooks/documents.
This causes the planning and creation of a new edition of the CD-ROM.
Updating of CD-ROMs always follows, with a certain delay, the updating of the single handbooks com-
posing the collection.
User Manual
Preface
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 118/308
User Manual
Safety, EMC, EMF, ESD Norms and Equipment Label-
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 19/308
1 Safety, EMC, EMF, ESD Norms and
Equipment Labelling
This chapter describes the equipment labelling and the norms mandatory or suggested that must be con-
sidered to avoid injuries on persons and/or damage to the equipment.
This chapter is organized as follows:
– Declaration of conformity to CE marking and Countries List
– Specific label for MPR equipment
– Applicable standards and recommendations
– Safety Rules
– Electromagnetic Compatibility (EMC norms)
– Equipment protection against electrostatic discharges
– Cautions to avoid equipment damage
User Manual
Safety, EMC, EMF, ESD Norms and Equipment Label-
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 120/308
1.1 Declaration of conformity to CE marking and Countries List
Indication of the countries where the equipment is intended to be used: Austria (AT) - Belgium (BE)
- Bulgaria (BG) - Switzerland/Liechtenstein (CH) - Cyprus (CY) - Czech Republic (CZ) - Germany (DE)
- Denmark (DK) - Estonia (EE) - Finland (FI) - France (FR) - Greece (GR) - Hungary (HU) – Italy (IT) -
Ireland (IE) - Iceland (IS) - Lithuania (LT) – Luxembourg (LU) - Latvia (LV) - Malta (MT) - Netherlands (NL)
- Norway (NO) –Poland (PL) – Portugal (PT) - Romania (RO) – Spain (SP) - Sweden (SE) - Slovenia (SI)
- Slovak Republic (SK) -United Kingdom (UK)
Indication of the intended use of the equipment: Point to Point PDH/Ethernet Transport radio Link
User Manual
Safety, EMC, EMF, ESD Norms and Equipment Label-
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 21/308
1.2 Specific label for MPR equipment
The label is sticked on the MSS-1c and on the MPT-HC/MPT-MC.
Field Field Name Note
A Alcatel-Lucent Logo
B Equipment acronym
C Power Supply range See NB 1 for MSS-1c
See NB 2 for MPT-HC
See NB 3 for MPT-MCD Current range
E European Community Logo
F Not harmonized frequency logo
G WEEE Logo
H Electrostatic Device Logo
NB 1: – 38.4 V / - 57.6 V; 3.3 A max.
NB 2: – 28 V / - 58 V; 1.6 A / 0.8 A
NB 3: – 28 V / - 58 V; 1.6 A / 0.8 A
1.3 Applicable standards and recommendations
1999/5/CE of 09 March 1999
Safety: EN 60950, EN 60825-1, EN 60825-2, EN 50385
EMC: EN 301 489-1, EN 301 489-4
Spectrum: EN 302 217-2-2
User Manual
Safety, EMC, EMF, ESD Norms and Equipment Label-
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 122/308
1.4 Safety Rules
1.4.1 General Rules
Before carrying out any installation, turn-on, tests or operation and maintenance operations, read carefully
the related sections of this Manual, in particular:
– Hardware Installation
– Commissioning
– Maintenance and Upgrade
Observe safety rules
– When equipment is operating nobody is allowed to have access inside on the equipment parts which
are protected with Cover Plate Shields removable with tools.
– In case of absolute need to have access inside, on the equipment parts when it is operating this is
allowed exclusively to service personnel, where for Service Personnel or Technical assistance is
meant:
• "personnel which has adequate Technical Knowledge and experience necessary to be aware
of the danger that he might find in carrying out an operation and of the necessary measure-
ments to reduce danger to minimum for him and for others".
• The Service Personnel can only replace the faulty units with spare parts.
• The Service Personnel is not allowed to repair: hence the access to the parts no specified is
not permitted.
• The keys and/or the tools used to open doors, hinged covers to remove parts which give access
to compartments in which are present high dangerous voltages must belong exclusively to the
service personnel.
– For the eventual cleaning of the external parts of the equipment, absolutely do not use any inflam-
mable substance or substances which in some way may alter the markings, inscriptions ect.
– It is recommended to use a slightly wet cleaning cloth.
The Safety Rules stated in the handbook describe the operations and/or precautions to observe to safe-
guard service personnel during the working phases and to guarantee equipment safety, i.e., not exposing
persons, animals, things to the risk of being injured/damaged.
Whenever the safety protection features have been impaired, REMOVE POWER.
To cut off power proceed to switch off the power supply units as well as cut off power station upstream
(rack or station distribution frame).
The safety rules described in this handbook are distinguished by the following symbol and statement:
User Manual
Safety, EMC, EMF, ESD Norms and Equipment Label-
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 23/308
1.4.2 Labels Indicating Danger, Forbiddance, Command
It is of utmost importance to follow the instructions printed on the labels affixed to the units and assemblies.
– dangerous electrical voltages
– harmful optical signals
– risk of explosion
– moving mechanical parts
– heat-radiating Mechanical Parts
– microwave radiations
Pay attention to the information stated in the following, and proceed as instructed.
The symbols presented in following paragraphs are all the possible symbols that could be present on Alca-
tel-Lucent equipment, but are not all necessarily present on the equipment this handbook refers to.
Dangerous Electrical Voltages
[1] Labeling
The following warning label is affixed next to dangerous voltages (>42.4 Vp; >60 Vdc).
If it is a Class 1 equipment connected to mains, then the label associated to it will state that the equip-
ment will have to be grounded before connecting it to the power supply voltage, e.g.:
[2] Safety instructions
DANGER! Possibility of personal injury:
Carefully observe the specific procedures for installation / turn-up and commissioning / maintenance
of equipment parts where D.C. power is present, described in the relevant installation / turn-up and
commissioning / maintenance documents and the following general rules:
• Personal injury can be caused by -48VDC. Avoid touching powered terminals with any exposed
part of your body.
• Short circuiting, low-voltage, low-impedance, DC circuits can cause severe arcing that can
result in burns and/or eye damage. Remove rings, watches, and other metal jewelry before
working with primary circuits. Exercise caution to avoid shorting power input terminals.
Note
User Manual
Safety, EMC, EMF, ESD Norms and Equipment Label-
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 124/308
Risks of Explosions: labeling and safety instructions
This risk is present when batteries are used, and it is signaled by the following label:
Therefore, slits or apertures are made to let air circulate freely and allow dangerous gasses to down flow
(battery-emitted hydrogen). A 417-IEC-5641 Norm. compliant label is affixed next to it indicating that the
openings must not be covered up.
Moving Mechanical Parts: labeling and safety instructions
The following warning label is affixed next to fans or other moving mechanical parts:
Before carrying out any maintenance operation see that all the moving mechanical parts have been
stopped.
Equipment connection to earth
Terminals for equipment connection to earth , to be done according to international safety standards, are
pointed out by the suitable symbol:
The position of earth connection terminals is specified in the Hardware Installation section.
User Manual
Safety, EMC, EMF, ESD Norms and Equipment Label-
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 25/308
Heat-radiating Mechanical Parts: labeling and safety instructions
The presence of heat-radiating mechanical parts is indicated by the following warning label in compliancy
with IEC 417 Norm, Fig.5041:
DANGER! Possibility of personal injury:
Carefully observe the specific procedures for installation / turn-up and commissioning / maintenance of
equipment parts where heat-radiating mechanical parts are present, described in the relevant installation
/ turn-up and commissioning / maintenance documents and the following general rule:
Personal injury can be caused by heat. Avoid touching powered terminals with any exposed part of your
body.
Optical safety
The equipment contains Class 1 laser component according to IEC 60825-1 (par. 5).
CLASS 1 LASER PRODUCT
The laser source is placed in the optional SFP plug-in, which has to be installed in the MSS-1c. The laser
source is placed in the left side of the SFP plug-in.
According to the IEC 60825-1 the explanatory label is not sticked on the equipment due to the lack of
space.
Microwave radiations (EMF norms)
Equipment emitting RF power (Reminder from site preparation procedure):
The site must be compliant with ICNIRP guidelines or local regulation if more restrictive.
The following rules should be strictly applied by Customer:
– Non authorized persons should not enter the compliance boundaries, if any, for the general public.
– Compliance RF boundaries, if any, related to Electro Magnetic Field exposure must be marked.
– Workers should be allowed to switch-off the power if they have to operate inside compliance bound-
aries.
– Assure good cable connection.
– Install the antenna as high as possible from floor or area with public access ( if possible the cylinder
delimitating the compliance boundaries, if any, or the cylinder corresponding to the transmission
area directly in front of antenna with the same diameter as the antenna, more than 2 meters high).
User Manual
Safety, EMC, EMF, ESD Norms and Equipment Label-
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 126/308
– Install the antenna as far as possible from other existing equipment emitting RF power.
Anyway remind that someone standing in front of the 9500 MPR antenna may cause traffic shutdown.
Place the relevant stickers:
EMF emission warning sign
On the site when applicable (when people can cross the compliance boundaries and/or the transmission
area of the antenna, i.e. roof top installation)
– Warning label "Do not stand on the antenna axis"
On the mast (front side)
– EMF emission warning sign (Yellow and black) to be placed at bottom of antenna, visible by some-
one moving in front of the antenna (roof top installation)
On the antenna (rear side)
– EMF emission warning sign, placed on the antenna.
1.5 Electromagnetic Compatibility (EMC norms)
The equipment's EMC norms depend on the type of installation being carried out (cable termination,
grounding etc.,) and on the operating conditions (equipment, setting options of the electrical/electronic
units, presence of dummy covers, etc.).
Before carrying out any installation, turn-on, tests & operation and maintenance operations, read carefully
the related sections of this Manual, in particular:
– Hardware Installation
– Maintenance and Upgrade
The norms set down to guarantee EMC compatibility, are distinguished inside this Manual by the symbol
and term:
EMC Norms
[1] EMC General Norms - Installation
• All connections (towards the external source of the equipment) made with shielded cables use
only cables and connectors suggested in this Manual or in the relevant Plant Documentation,
or those specified in the Customer's "Installation Norms" (or similar documents)
• Shielded cables must be suitably terminated
• Install filters outside the equipment as required
User Manual
Safety, EMC, EMF, ESD Norms and Equipment Label-
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 27/308
• Ground connect the equipment utilizing a conductor with proper diameter and impedance
• Mount shields (if utilized), previously positioned during the installation phase, but not before
having cleaned and degrease it
• Before inserting the shielded unit proceed to clean and degrease all peripheral surfaces (con-
tact springs and connection points, etc.)
• Screw fasten the units to the subrack
• To correctly install EMC compatible equipment follow the instructions given
[2] EMC General Norms - Turn-on, Tests & Operation
• Preset the electrical units as required to guarantee EMC compatibility
• Check that the equipment is operating with all the shields properly positioned (dummy covers,
ESD connector protections, etc.)
• To properly use EMC compatible equipment observe the information given
[3] EMC General Norms - Maintenance
• Before inserting the shielded unit, which will replace the faulty or modified unit, proceed to clean
and degrease all peripheral surfaces (contact springs and connection points, etc.)
• Clean the dummy covers of the spare units as well
• Screw fasten the units to the subrack.
1.6 Equipment protection against electrostatic discharges
Before removing the ESD protections from the monitors, connectors etc., observe the precautionary mea-
sures stated. Make sure that the ESD protections have been replaced and after having terminated the
maintenance and monitoring operations.
Most electronic devices are sensitive to electrostatic discharges, to this concern the following warning
labels have been affixed:
Observe the precautionary measures stated when having to touch the electronic parts during the instal-
lation/maintenance phases.
Workers are supplied with anti static protection devices consisting of:
– an elasticized band worn around the wrist
– a coiled cord connected to the elasticized band and to the stud on the subrack
User Manual
Safety, EMC, EMF, ESD Norms and Equipment Label-
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 128/308
1.7 Cautions to avoid equipment damage
a. Anti static protection device kit
Whenever is necessary to handle spare parts and cards out of their own box, this kit (Illustration
below) must be always warn and its termination must be connected to a grounded structure, to avoid
the possible damage of the electronic devices for electrostatic discharges.
Anti static protection device kit
b. Screw fixing
In normal operation conditions, all screws (for unit box closing, cable fixing, etc.) must be always
tightened to avoid item detachment and to ensure the equipment EMI-EMC performance.
The screw tightening torque must be:
2.8 kg x cm (0.28 Newton x m) ±10 %
2.4317 in lb (0.2026 ft lb) ±10 %
Exceeding this value may result in screw breaking.
c. MSS-1c-ODU cable disconnection / connection
Before to disconnect or connect the MSS-1c-ODU cable (at MSS-1c or ODU side) switch off the cor-
responding MSS-1c Unit.
User Manual
Product information and planning
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 29/308
2 Product information and planning
– 9500 Family overview (par. 2.1 on page 31)
• 9500 MPR System Family (par. 2.1.1 on page 35)
• Family elements described in this User Manual (par. 2.1.2 on page 36)
• MSS-1c (par. 2.1.3 on page 36)
• MPT-HC (par. 2.1.4 on page 37)
• MPT-MC (par. 2.1.5 on page 37)
• MSS-1c to MPT-HC interconnection (par. 2.1.6 on page 38)
• MSS-1c to MPT-MC interconnection (par. 2.1.7 on page 40)
• Antennas (par. 2.1.8 on page 40)
– Radio capacity, channelling and modulation (MPT-HC/MPT-MC) (par. 2.2 on page 41)
– Standard Features (par. 2.3 on page 44)
– Radio Configurations (par. 2.4 on page 44)
– Typical System Configurations (par. 2.5 on page 45)
– Environmental and Electrical Characteristics (par. 2.6 on page 46)
• General characteristics (MSS-1c) (par. 2.6.1 on page 46)
• General characteristics (MPT-HC/MPT-MC) (par. 2.6.2 on page 47)
• MPT-HC characteristics (par. 2.6.4 on page 49)
– 6 to 13 GHz (par. 2.6.4.1 on page 49)
– 15 to 38 GHz (par. 2.6.4.2 on page 49)
• MPT-MC characteristics (par. 2.6.3 on page 48)
– 6 to 13 GHz (par. 2.6.3.1 on page 48)
– 15 to 38 GHz (par. 2.6.3.2 on page 48)
• Radio performances (par. 2.6.5 on page 49)
• General characteristics (MSS-1c) (par. 2.6.1 on page 46)
• General characteristics (Power Extractor) (par. 2.6.6 on page 50)
– Parts Lists (par. 2.7 on page 51)
• MSS-1c (par. 2.7.1 on page 51)
• MPT-HC optical interface option (par. 2.7.2 on page 51)
• MPT-HC with internal diplexer (par. 2.7.3 on page 52)
• MPT-MC with internal diplexer (par. 2.7.4 on page 54)
• MPT-HC/MPT-MC with external diplexer (7/8 GHz) (par. 2.7.5 on page 56)
– Functional description (par. 2.8 on page 59)
• MSS-1c (Indoor Unit) (par. 2.8.1 on page 59)
– Power supply (par. 2.8.1.2 on page 61)
– Ethernet switch (par. 2.8.1.3 on page 61)
– E1 Interface (par. 2.8.1.4 on page 61)
– MPT Interface (par. 2.8.1.5 on page 62)
• Fan unit (par. 2.8.2 on page 63)
• MPT-HC (par. 2.8.3 on page 64)
– MPT-HC block diagram (par. 2.8.3.1 on page 66)
User Manual
Product information and planning
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 130/308
– RSSI Monitoring Point (par. 2.8.3.2 on page 72)
– Waveguide Flange Data (par. 2.8.3.3 on page 72)
• Power Extractor (par. 2.8.4 on page 73)
• MPT-MC (par. 2.8.5 on page 74)
• Radio Transmission Features with MPT-HC/MPT-MC (par. 2.8.6 on page 75)
– Frequency Agility (par. 2.8.6.1 on page 75)
– Automatic Transmit Power Control (ATPC) (par. 2.8.6.2 on page 75)
– Transmitted power control: RTPC function (par. 2.8.6.3 on page 76)
– Power Monitoring (par. 2.8.6.4 on page 76)
– Adaptive Equalization (par. 2.8.6.5 on page 76)
– Link identifier (par. 2.8.6.6 on page 76)
– Loopbacks (par. 2.8.6.7 on page 76)
– Loopback activation (par. 2.8.6.8 on page 77)
– Loopback life time (par. 2.8.6.9 on page 78)
• TMN communication channels (par. 2.8.7 on page 78)
• Traffic profiles (par. 2.8.8 on page 79)
– TDM2TDM (par. 2.8.8.1 on page 81)
– TDM2Eth (par. 2.8.8.2 on page 82)
– ETH2ETH (par. 2.8.8.3 on page 83)
• Ethernet Traffic Management (par. 2.8.9 on page 84)
– Bridge type change (par. 2.8.9.1 on page 84)
– Reserved Multicast Addresses (par. 2.8.9.2 on page 84)
• Quality Of Services (QoS) (par. 2.8.10 on page 85)
– QoS in the MSS-1c (par. 2.8.10.1 on page 85)
– QoS in the MPT (par. 2.8.10.2 on page 87)
• Cross-connections (par. 2.8.11 on page 89)
– E1 Cross-connection (par. 2.8.11.1 on page 89)
– Ethernet flows (par. 2.8.11.2 on page 90)
• Synchronization (par. 2.8.12 on page 91)
– Synchronization overview (par. 2.8.12.1 on page 91)
– Synchronization interface (par. 2.8.12.2 on page 93)
User Manual
Product information and planning
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 31/308
2.1 9500 Family overview
9500MPR introduces new elements to the microwave packet family. The most compact IDU solutions
(MSS-1c) for E1 and Ethernet hybrid connectivity as well as with a zero footprint solution (no IDU)
addressing full out-door applications. The new set of multipurpose ODUs, the MPT addressing any appli-
cation in the microwave domain. Stand alone as well as coupled in split mount solutions applications
depending on the network requirement and layout. The MPT is available in a variety of flavors to address
in the most cost effective the different part of the network, this also include millimeter wavelength.
The 9500 Microwave Packet Radio (MPR) is a microwave digital radio family that supports both PDH and
packet data (Ethernet) for migrating from TDM to IP. The 9500 MPR provides a generic, modular IP
platform for multiple network applications (including 2G/3G/HSDPA/WiMAX backhauling to Metro
Ethernet areas) to accommodate broadband services. The 9500 MPR radio family supports low, medium,
and high capacity applications using European data rates, frequencies, channel plans, and tributary
interfaces:
– TDM/PDH Data Rates: E1
– ATM Data Rates: E1
– Ethernet Data Speed: 10, 100, 1000 Mb/s
– RF Frequency Range: 6 to 38 GHz
Three types of Indoor Units are available:
1) MSS-8, a 2U shelf, connected to an outdoor RF unit (split mount system).
Supported ODUs:
– ODU300
– MPT-HC
– MPT-MC
User Manual
Product information and planning
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 132/308
2) MSS-4, one 1U shelf, connected to an outdoor RF unit (split mount system).
Supported ODUs:
– ODU300
– MPT-HC
– MPT-MC
3) MSS-1c. Compact IDU that complements the existing portfolio addressing the last mile, the far
end application in nodal solution and cost optimized point-to-point applications.
Its small size of 1U height and half rack width drastically reduces the space consumption in busy
sites.
Supported ODUs:
– MPT-HC
– MPT-MC
MPT is a new multipurpose ODU to address any microwave application, extremely compact in size pro-
viding:
– MPT-MC: 155 Mbps max.
– MPT-HC: 340 Mbps max.
MPT-xx can be deployed in stand-alone configuration (9500 MPR-e) or it can be deployed in split mount
solution connected to any MSS-x IDU.
– Up to 12 MPT connected to an MSS-8; highest density ever
– Up to 6 MPT connected to an MSS-4; highest density ever
– Up to 2 MPT HC/MC connected to MSS-1c (up to 1 limited in the current version)
9500 MPR-e is the stand alone, full outdoor application of the MPT xx to address full Ethernet site back-
hauling (fix or mobile alike) and to address converged MPLS metro networks reducing the number of
deployed equipment.
The 9500 MPR innovative solutions mainly are:
[1] Multiservice aggregation layer: the capacity to use Ethernet as a common transmission layer to
transport any kind of traffic, independently by the type of interface. Ethernet becomes the conver-
gence layer.
[2] Service awareness: traffic handling and quality management, queuing traffic according to the type
of service assigned, independently by the type of interface
[3] Packet node: no service aggregation limits with all traffic aggregated in packets, in term of: capacity,
type of service requirements and type of interface
[4] Service-driven adaptive modulation: fully exploit the air bandwidth in its entirety by changing mod-
ulation scheme according to the propagation availability and allocate transport capacity, discrimi-
nating traffic by different services, only possible in a packet-based environment.
User Manual
Product information and planning
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 33/308
[1] Multiservice aggregation layer
Figure 1. Multiservice Aggregation Layer
9500 MPR aggregates and carries over a COMMON PACKET LAYER: TDM 2G, 3G and IP/Ethernet. This
allows sharing of common packet transmission infrastructures, regardless of the nature of carried traffic.
Due to the nature of Ethernet, each service can be discriminated based on several parameters like quality
of service.
Mapping different access technologies over Ethernet is achieved by standardized protocols like circuit
emulation and pseudo-wire.
[2] Service awareness
Figure 2. Service Awareness
Service awareness means the ability to discriminate the different traffic types carried over the converged
Ethernet stream. The traffic flow can be composed by E1 and/or IP/Eth, coming from different sources,
and therefore having different requirements.
Service awareness is what allows identifying the traffic types, and in case of the non real time variable
bit rate one, optimize the band with overbooking of the radio scarce resource.
User Manual
Product information and planning
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 134/308
[3] Packet node
Figure 3. Packet Node
9500 MPR offers a SINGLE PACKET MATRIX able to switch, aggregate and handle any of the possible
incoming traffic types with virtually no capacity limits (up to 10 GBps).
[4] Service-driven adaptive modulation
Figure 4. Service-driven Packet Adaptive Modulation
Traffic with high priority will always have bandwidth available, like voice (deterministic approach).
Broadband traffic is discriminated by QoS dynamically, with modulation scheme changes driven by
propagation conditions.
User Manual
Product information and planning
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 35/308
2.1.1 9500 MPR System Family
Figure 5. 9500 MPR System Family
9500 MPR in the stand alone (zero-footprint) architecture is built by only one unit for Ethernet applications:
– Outdoor Unit.
– Outdoor Unit is connected to the MPLS metro networks equipment with one coaxial cable for the
power supply and one Ethernet optical or electrical cable (with MPT).
9500 MPR in the split mount architecture is built by two separate units:
– MSS (Microwave Service Switch): indoor unit for split mount and stand alone configurations (Ether-
net uplink)
– Outdoor Unit.
User Manual
Product information and planning
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 136/308
2.1.2 Family elements described in this User Manual
In this User Manual the access solution with the MSS-1c and MPT-HC/MPT-MC is described:
The implemented radio configuration is 1+0.
The MSS-1c can collect up to 10 TDM flows and Ethernet flows.
The MSS-1c interfaces the Outdoor Unit (MPT-HC or MPT-MC) thanks to its Ethernet interface.
MPT-HC or MPT-MC is in a charge of transporting the flows in an efficient way (bandwidth optimization,
Quality of service, respect to TDM contraints ....).
2.1.3 MSS-1c
The MSS-1c provides user port interface, cross-connection and switching management.
The cross-connection matrix implements all the cross-connections between the User ports (4 Ethernet
ports and 10 E1 streams) and the Radio port. The matrix is a standard Ethernet switch, based on VLAN,
assigned by the MCT.
The 10xE1 enter the LIU and then the IWF, which manages the encapsulation/reconstruction of PDH data
to/from standard Ethernet packets and sends/receives standard Ethernet packets to/from the Ethernet
switch.
The Radio Interface interfaces the MPT-HC or the MPT-MC. The radio interface is a standard GbEth inter-
face electrical for MPT-MC, electrical or optical for MPT-HC. It sends/receives standard Ethernet packets
to/from the Ethernet switch.
In case of electrical radio interface, on the same cable is also sent the power supply for the MPT by using
the Power Feed over Ethernet (PFoE) function.
To connect MSS-1c and MPT-HC with only one electrical cable, the Power Extractor must be installed
close to the MPT-HC. In this case the interconnection between the MSS-1c and the MPT-HC is made with
a single electrical Ethernet cable by using the Power Feed over Ethernet (Ethernet traffic and Power Sup-
ply on the same cable). The Power Extractor then separates the Power Supply from the Ethernet traffic,
which are separately sent to the MPT-HC.
The MPT-HC can be connected also by using an optical cable for the Ethernet traffic and a coaxial cable
for the power supply.
Note
User Manual
Product information and planning
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 37/308
2.1.4 MPT-HC
MPT-HC is a Microwave Equipment capable of transporting the Ethernet traffic over an RF radio channel.
MPT-HC is a microprocessor-controlled equipment that interfaces the MSS-1c with the antenna.
The input interface can be a standard electrical Giga Ethernet interface, connected to the Power Extractor
as shown in Figure 8. or a standard optical Giga Ethernet interface, connected to the MSS-1c as shown
in Figure 9..
The Ethernet traffic is transmitted over the radio channel according to the configured QoS and to the
scheduler algorithms.
Transmitter circuits in the MPT-HC consist of Ethernet input interface, modulator, local oscillator, upcon-
verter/mixer, power amplifier, and diplexer.
Receiver circuits consist of diplexer, low-noise amplifier, local oscillator, downconverter/mixer, automatic
gain control, demodulator and Ethernet output interface.
The microprocessor manages the frequency, transmit power alarming, and performance monitoring.
The power is provided from the Power Extractor to the MPT-HC DC-DC converter through a dedicated
power supply cable.
The MPT-HC is frequency dependent.
Figure 6. MPT-HC
2.1.5 MPT-MC
MPT-MC is similar to MPT-HC from architecture standpoint. MPT-MC has limited capacity vs MPT-HC and
is natively Ethernet powered (no Power Extractor is required).
Figure 7. MPT-MC
User Manual
Product information and planning
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 138/308
2.1.6 MSS-1c to MPT-HC interconnection
2.1.6.1 Electrical cable
One electrical Ethernet cable connects the MSS-1c to its MPT-HC.
The max cable length is 100 m.
The Ethernet electrical cable is provided with connectors to be mounted on site with the specific RJ45 tool
(1AD160490001).
Figure 8. MPT-HC connection (electrical cable)
With the MPT-HC the Power Extractor must be installed close to the MPT-HC. In this case the intercon-
nection between the MSS-1c and the MPT-HC is made with a single electrical Ethernet cable by using
the Power Feed over Ethernet (Ethernet traffic and Power Supply on the same cable). The Power Extrac-
tor then separates the Power Supply from the Ethernet traffic, which are separately send to the MPT-HC.
Note
User Manual
Product information and planning
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 39/308
2.1.6.2 Optical cable
One optical Ethernet cable connects the MSS-1c to its MPT-HC.
The max cable length is 350 m.
A coaxial cable connects the MPT-HC to the MSS-1c (Figure 9) or to Station battery (Figure 10).
Figure 9. MPT-HC connection (optical cable + power supply cable to MSS-1c)
Figure 10. MPT-HC connection (optical cable + power supply cable to Station battery)
User Manual
Product information and planning
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 140/308
2.1.7 MSS-1c to MPT-MC interconnection
One electrical Ethernet cable connects the MSS-1c to its MPT-MC.
The max cable length is 100 m.
The Ethernet electrical cable is provided with connectors to be mounted on site with the specific RJ45 tool
(1AD160490001).
Figure 11. MPT-MC connection
2.1.8 Antennas
Antennas for direct mounting an MPT are available in diameters from 0.3 m to 1.8 m, depending on the
frequency band.
A polarization rotator is included within the antenna collar, and direct-mounting equal or unequal loss
couplers are available for single antenna protected operation.
Antenna mounts are designed for use on industry-standard 114 mm OD pipe-mounts.
An MPT can also be used with standard antennas via a remote-mount kit and flexible waveguide.
User Manual
Product information and planning
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 41/308
2.2 Radio capacity, channelling and modulation (MPT-HC/MPT-MC)
Table 1. Radio capacity, channelling scheme and modulation (Static Modulation)
Channel Spacing
(MHz)
FCM Mode ETSI Class # E1
(TDM2TDM)
Typical Ethernet
Throughput (1518 bytes)
3.5
QPSK 2 2 4,2 Mbit/s
8PSK 2 3 6,8 Mbit/s
16 QAM 4 4 8,5 Mbit/s
32 QAM 4 5 10,8 Mbit/s
64 QAM 5 6 13,5 Mbit/s
7
QPSK 2 4 8,8 Mbit/s
8PSK 2 6 13,5 Mbit/s
16 QAM 4 9 19,4 Mbit/s
32 QAM 4 11 24,2 Mbit/s
64 QAM 5 13 29,6 Mbit/s
128 QAM 5 16 35,4 Mbit/s
256 QAM (NB3) 6 19 40,6 Mbit/s
14
QPSK 2 9 19,9 Mbit/s
8PSK 2 14 30,0 Mbit/s
16 QAM 4 19 40,7 Mbit/s
32 QAM 4 23 50,3 Mbit/s
64 QAM 5 29 62,0 Mbit/s
128 QAM 5 34 73,5 Mbit/s
256 QAM (NB3) 6 41 86,7 Mbit/s
28
QPSK 2 19 41,1 Mbit/s
QPSK 2 (NB1) 20 42,8 Mbit/s
8PSK 2 29 61,9 Mbit/s
16 QAM 4 39 83,5 Mbit/s
16 QAM 4 (NB1) 41 87,1 Mbit/s
32 QAM 4 50 106,9 Mbit/s
64 QAM 5 60 128,3 Mbit/s
128 QAM 5 71 151,8 Mbit/s
256 QAM (NB3) 6 85 180,0 Mbit/s
40 (NB2)
64 QAM 5 88 186,0 Mbit/s
128 QAM 5 104 220,0 Mbit/s
User Manual
Product information and planning
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 142/308
N.B.1: New ETSI mask.
N.B.2: MPT-MC does not support this Channel Spacing.
N.B.3: MPT-MC does not support this FCM mode.
56 (NB2)
16 QAM 4 75 159,1 Mbit/s
16 QAM 4 (NB1) 76 161,0 Mbit/s
32 QAM 4 92 195,4 Mbit/s
64 QAM 5 119 252,0 Mbit/s
128 QAM 5 141 298,0 Mbit/s
256 QAM 6 160 339,1 Mbit/s
User Manual
Product information and planning
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 43/308
Table 2. Radio capacity, channelling scheme and modulation (Adaptive Modulation)
Channel Spacing
(MHz)
ACM Mode
Reference
ETSI Class Modulation range Typical Ethernet
Throughput
(1518 bytes)
3.5
QPSK 2 QPSK to 64 QAM 4,3 Mbit/s
16 QAM 4 16 QAM to 64 QAM 8,5 Mbit/s
7
QPSK 2 QPSK to 256 QAM 8,8 Mbit/s
16 QAM 4 16 QAM to 256 QAM 19,4 Mbit/s
32 QAM 4 32 QAM to 256 QAM 24,2 Mbit/s
64 QAM 5 64 QAM to 256 QAM 29,6 Mbit/s
14
QPSK 2 QPSK to 256 QAM 19,9 Mbit/s
16 QAM 4 16 QAM to 256 QAM 40,7 Mbit/s
32 QAM 4 32 QAM to 256 QAM 50,3 Mbit/s
64 QAM 5 64 QAM to 256 QAM 62,0 Mbit/s
28
QPSK 2 QPSK to 256 QAM 41,0 Mbit/s
QPSK 2U QPSK to 256 QAM 42,8 Mbit/s
16 QAM 4 16 QAM to 256 QAM 83,5 Mbit/s
16 QAM 4U 16 QAM to 256 QAM 87,1 Mbit/s
32 QAM 4 32 QAM to 256 QAM 106,9 Mbit/s
64 QAM 5 64 QAM to 256 QAM 128,3 Mbit/s
40 (NB1) 64 QAM 5 64 QAM to 128 QAM 186,0 Mbit/s
56 (NB1)
16 QAM 4 16 QAM to 256 QAM 159,0 Mbit/s
16 QAM 4U 16 QAM to 256 QAM 161,0 Mbit/s
32 QAM 4 32 QAM to 256 QAM 195,4 Mbit/s
64 QAM 5 64 QAM to 256 QAM 251,9 Mbit/s
N.B.1: MPT-MC does not support this Channel Spacing.
User Manual
Product information and planning
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 144/308
2.3 Standard Features
More radio and site scalability and flexibility for installation teams:
– Limited need for factory presetting channel frequency or bandwidth
– Supports cellular mobile networks, and microcellular network back and common carrier, private
carrier and data networks, and utility haul applications.
– 2G, 2.5G, and 3G network compatible
– Outdoor Unit capacity and modulation independent
– Outdoor Unit can support either split-mount and full-outdoor architecture with the same hardware
– Flexible aggregate capacity sharing between E1 and Ethernet
– Adaptive packet transport that improves performance for priority services
– Output power agility
– ATPC
– Adaptive Modulation
– Packet-based internal cross-connect
– TDM MEF8 encapsulation
– Electrical GE interfaces
– Software-based configuration
– High Switching Capacity
2.4 Radio Configurations
In the current release the following radio configuration is available:
– 1+0 in split-mount
User Manual
Product information and planning
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 45/308
2.5 Typical System Configurations
– TDM Over Ethernet Packet Node - Mapping of 10 E1 TDM on Ethernet (Figure 12.)
N.B. In this case a connected MPT is needed in order to configure the cross-connections.
– TDM and Ethernet Terminal Packet Transport 10 E1 TDM and 1 Radio Direction (Figure 13.)
MSS-1c
Packet SW
10E1TDM
Interface
Built-in
Ethernet
Figure 12. TDM Over Ethernet Packet Node - Mapping of 10 E1 TDM on Ethernet
MSS-1c
Packet SW
10E1TDM
Interface
Built-in
Ethernet
Radio
Interface
MPT
Figure 13. TDM and Ethernet Terminal Packet Transport 10 E1 TDM and 1 Radio Direction
User Manual
Product information and planning
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 146/308
2.6 Environmental and Electrical Characteristics
– General characteristics (MSS-1c) (par. 2.6.1)
– General characteristics (MPT-HC/MPT-MC) (par. 2.6.2)
– MPT-MC characteristics (par. 2.6.3)
– MPT-HC characteristics (par. 2.6.4)
– Radio performances (par. 2.6.5)
– General characteristics (Power Extractor) (par. 2.6.6)
2.6.1 General characteristics (MSS-1c)
Power Injector
Input Voltage range -38.4 to -57.6 Vdc
Standards Compliance (Power Injector)
EMC EN 301 489-1, EN 301 489-4, EN 55022 Class B
Stationary use ETS 300 019 1-3, Class 3.2
Storage ETS 300 019 2-1, Class 1.2
Transportation ETS 300 019 2-2, Class 2.3
Safety EN 60950
Environmental
Operating Temperature -20° to +50° C (without FAN unit)
-20° to +65° C (with FAN unit)
Cold start-up -40° C
Humidity 0 to 95%, non condensing
Management
Protocol SNMP
Interface, electrical Ethernet 10/100/1000 Base-T
Interface, electrical physical RJ-45
Routing Protocols supported Static routing
Network Management Alcatel-Lucent 1350 OMS
Alcatel-Lucent 1352 Compact
Alcatel-Lucent 5620 SAM
User Manual
Product information and planning
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 47/308
2.6.2 General characteristics (MPT-HC/MPT-MC)
General with MPT-HC
Operating Frequency Range 6 - 38 GHz
Max. Ethernet throughput 340 Mbps
Bandwidth up to 56 MHz
Modulation Options in FCM QPSK, 8PSK, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM
Adaptive Modulation QPSK, 8PSK, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM
General with MPT-MC
Operating Frequency Range 6 - 38 GHz
Max. Ethernet throughput 155 Mbps
Bandwidth up to 28 MHz
Modulation Options in FCM QPSK, 8PSK, 16 QAM, 32 QAM, 64 QAM, 128 QAM
Adaptive Modulation QPSK, 8PSK, 16 QAM, 32 QAM, 64 QAM, 128 QAM
Radio Path Protection Options
Non Protected, 1+0
Standards Compliance (MPT-HC/MPT-MC)
EMC EN 301 489-1, EN 301 489-4, EN 55022 Class B
Stationary use ETS 300 019, Class 4.1
Storage ETS 300 019, Class 1.2
Transportation ETS 300 019, Class 2.3
Safety IEC 60950-1/EN 60950-1
Radio Frequency EN 302 217 Classes 2, 4 & E5
Water Ingress IEC 60529 (IPX6)
Environmental
Operating Temperature
(Guaranteed)
-33° to +55° C
Start up temperature from low
temperature
-40° C
Humidity
(Guaranteed)
0 to 100%
User Manual
Product information and planning
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 148/308
2.6.3 MPT-MC characteristics
2.6.3.1 6 to 13 GHz
System
Frequency Range, GHz 5.925 -
6.425
6.425 -
7.11
7.125 -
7.9
7.725 -
8.5
10.7 -
11.7
12.75 -
13.25
T-R Spacings supported MHz 252.04 340 154-161-
168-196
119-126-
294-305-
311-32
490-500-
530
266
Antenna Interface
Waveguide Type WR137 WR137 WR112 WR113 WR75 WR62
Typical power consumption 38 W
Guaranteed power consumption
2.6.3.2 15 to 38 GHz
System
Frequency Range, GHz 14.4 -
15.35
17.7 -
19.7
21.2 -
23.632
24.52 -
26.483
37.0 -
39.46
T-R Spacings supported MHz 420- 490 1008-
1010-
1560
1008-
1050-
1200-
1232
1008 1260
Antenna Interface
Waveguide Type WR62 WR42 WR42 WR42 WR28
Typical power consumption 38 W
Guaranteed power consumption
L6 GHz U6 GHz 7 GHz 8 GHz 11 GHz 13 GHz
40 W
15 GHz 18 GHz 23 GHz 26 GHz 38 GHz
40 W
User Manual
Product information and planning
9500 MPR-E Rel. 2.2.0
3DB 18782 AAAA Issue 1 49/308
2.6.4 MPT-HC characteristics
2.6.4.1 6 to 13 GHz
System
Frequency Range, GHz 5.925 -
6.425
6.425 -
7.11
7.125 -
7.9
7.725 -
8.5
10.7 -
11.7
12.75 -
13.25
T-R Spacings supported MHz 252.04 340 154, 161,
168, 196,
245
119; 126;
151.614;
208;
213,5;
266; 294;
305;
311.32
490-530 266
Antenna Interface
Waveguide Type WR137 WR137 WR112 WR113 WR75 WR62
Typical power consumption 38 W
Guaranteed power consumption
2.6.4.2 15 to 38 GHz
System
Frequency Range, GHz 14.4 -
15.35
17.7 -
19.7
21.2 -
23.632
24.52 -
26.483
37.0 -
39.46
T-R Spacings supported MHz 308-315-
322, 420,
490, 644,
728
1008-
1010,
1560, 340
1008-
1050-
1200-
1232
1008 1260
Antenna Interface
Waveguide Type WR62 WR42 WR42 WR42 WR28
Typical power consumption 38 W
Guaranteed power consumption
2.6.5 Radio performances
The radio performances are provided in the “Technical Description” document.
L6 GHz U6 GHz 7 GHz 8 GHz 11 GHz 13 GHz
42 W
15 GHz 18 GHz 23 GHz 26 GHz 38 GHz
42 W
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)
Mpr mss 1 c_user_manual (Alcatel Lucent)

Contenu connexe

Tendances

Huawei GGSN 9811 hardware and software
Huawei GGSN 9811 hardware and software Huawei GGSN 9811 hardware and software
Huawei GGSN 9811 hardware and software Mario Gordon
 
01 Bts3900 System Structure
01 Bts3900 System Structure01 Bts3900 System Structure
01 Bts3900 System StructureAtif Mahmood
 
M2000 operation-guide
M2000 operation-guideM2000 operation-guide
M2000 operation-guideVirak Sou
 
Umts transmission features presentation v1[1].0
Umts transmission features presentation v1[1].0Umts transmission features presentation v1[1].0
Umts transmission features presentation v1[1].0Abi Putra Taufik
 
Airscale Model site Quality Handbook -.pdf
Airscale Model site Quality Handbook -.pdfAirscale Model site Quality Handbook -.pdf
Airscale Model site Quality Handbook -.pdfHakeemUllah7
 
Huawei Call Reestablishment RAN14
Huawei Call Reestablishment RAN14Huawei Call Reestablishment RAN14
Huawei Call Reestablishment RAN14Eric Arantes
 
MINI-LINK PT_Node GUI Descriptions.pdf
MINI-LINK PT_Node GUI Descriptions.pdfMINI-LINK PT_Node GUI Descriptions.pdf
MINI-LINK PT_Node GUI Descriptions.pdffreedman701
 
33841146 protocolo-instalacion-rbs-ericsson-gsm-2106v3
33841146 protocolo-instalacion-rbs-ericsson-gsm-2106v333841146 protocolo-instalacion-rbs-ericsson-gsm-2106v3
33841146 protocolo-instalacion-rbs-ericsson-gsm-2106v3Rodrigo Trejo Riascos
 
Huawei rru5508 description
Huawei rru5508 descriptionHuawei rru5508 description
Huawei rru5508 descriptionDenmark Wilson
 
TCU upgrade and configure
TCU  upgrade and configureTCU  upgrade and configure
TCU upgrade and configureÄmjed Othman
 
519710952-6366-MW-HOP-Installation-Guidelines-Bhartij.pdf
519710952-6366-MW-HOP-Installation-Guidelines-Bhartij.pdf519710952-6366-MW-HOP-Installation-Guidelines-Bhartij.pdf
519710952-6366-MW-HOP-Installation-Guidelines-Bhartij.pdfluckychandel2
 
TDM Traffic Migration into IP Backhaul
TDM Traffic Migration into IP BackhaulTDM Traffic Migration into IP Backhaul
TDM Traffic Migration into IP BackhaulKhalil Al-Alami
 
Ericsson RBS RET Alarms Troubleshooting Guide Flow Chart v2
Ericsson RBS RET Alarms Troubleshooting Guide   Flow Chart v2Ericsson RBS RET Alarms Troubleshooting Guide   Flow Chart v2
Ericsson RBS RET Alarms Troubleshooting Guide Flow Chart v2Mohamed Abd El Razek Bakry
 
370410176 moshell-commands
370410176 moshell-commands370410176 moshell-commands
370410176 moshell-commandsnanker phelge
 
Zxsdr bs8906 e product description(configured with b8100) 20100825
Zxsdr bs8906 e product description(configured with b8100) 20100825Zxsdr bs8906 e product description(configured with b8100) 20100825
Zxsdr bs8906 e product description(configured with b8100) 20100825Adeep Asaad
 

Tendances (20)

Huawei GGSN 9811 hardware and software
Huawei GGSN 9811 hardware and software Huawei GGSN 9811 hardware and software
Huawei GGSN 9811 hardware and software
 
01 Bts3900 System Structure
01 Bts3900 System Structure01 Bts3900 System Structure
01 Bts3900 System Structure
 
Profinet Training
Profinet Training Profinet Training
Profinet Training
 
M2000 operation-guide
M2000 operation-guideM2000 operation-guide
M2000 operation-guide
 
Wcdma bts-alarm-descriptions
Wcdma bts-alarm-descriptionsWcdma bts-alarm-descriptions
Wcdma bts-alarm-descriptions
 
Summary 2G y 3G
Summary 2G y 3GSummary 2G y 3G
Summary 2G y 3G
 
63077585 idle-mode-parameter-optimization
63077585 idle-mode-parameter-optimization63077585 idle-mode-parameter-optimization
63077585 idle-mode-parameter-optimization
 
Umts transmission features presentation v1[1].0
Umts transmission features presentation v1[1].0Umts transmission features presentation v1[1].0
Umts transmission features presentation v1[1].0
 
Airscale Model site Quality Handbook -.pdf
Airscale Model site Quality Handbook -.pdfAirscale Model site Quality Handbook -.pdf
Airscale Model site Quality Handbook -.pdf
 
Huawei Call Reestablishment RAN14
Huawei Call Reestablishment RAN14Huawei Call Reestablishment RAN14
Huawei Call Reestablishment RAN14
 
MINI-LINK PT_Node GUI Descriptions.pdf
MINI-LINK PT_Node GUI Descriptions.pdfMINI-LINK PT_Node GUI Descriptions.pdf
MINI-LINK PT_Node GUI Descriptions.pdf
 
33841146 protocolo-instalacion-rbs-ericsson-gsm-2106v3
33841146 protocolo-instalacion-rbs-ericsson-gsm-2106v333841146 protocolo-instalacion-rbs-ericsson-gsm-2106v3
33841146 protocolo-instalacion-rbs-ericsson-gsm-2106v3
 
Huawei rru5508 description
Huawei rru5508 descriptionHuawei rru5508 description
Huawei rru5508 description
 
TCU upgrade and configure
TCU  upgrade and configureTCU  upgrade and configure
TCU upgrade and configure
 
519710952-6366-MW-HOP-Installation-Guidelines-Bhartij.pdf
519710952-6366-MW-HOP-Installation-Guidelines-Bhartij.pdf519710952-6366-MW-HOP-Installation-Guidelines-Bhartij.pdf
519710952-6366-MW-HOP-Installation-Guidelines-Bhartij.pdf
 
TDM Traffic Migration into IP Backhaul
TDM Traffic Migration into IP BackhaulTDM Traffic Migration into IP Backhaul
TDM Traffic Migration into IP Backhaul
 
Ericsson RBS RET Alarms Troubleshooting Guide Flow Chart v2
Ericsson RBS RET Alarms Troubleshooting Guide   Flow Chart v2Ericsson RBS RET Alarms Troubleshooting Guide   Flow Chart v2
Ericsson RBS RET Alarms Troubleshooting Guide Flow Chart v2
 
370410176 moshell-commands
370410176 moshell-commands370410176 moshell-commands
370410176 moshell-commands
 
Introduction to-zxsdr-products-gsm
Introduction to-zxsdr-products-gsmIntroduction to-zxsdr-products-gsm
Introduction to-zxsdr-products-gsm
 
Zxsdr bs8906 e product description(configured with b8100) 20100825
Zxsdr bs8906 e product description(configured with b8100) 20100825Zxsdr bs8906 e product description(configured with b8100) 20100825
Zxsdr bs8906 e product description(configured with b8100) 20100825
 

En vedette

Alcate lucent bts Installation and Commissioning
Alcate lucent bts Installation and CommissioningAlcate lucent bts Installation and Commissioning
Alcate lucent bts Installation and Commissioningengramjadislam78
 
Training report of Alcatel Lucent for 3G
Training report of Alcatel Lucent for 3GTraining report of Alcatel Lucent for 3G
Training report of Alcatel Lucent for 3Gengramjadislam78
 
Bts commissioning
Bts commissioningBts commissioning
Bts commissioningginorosido
 
Bts commissioning (alcatel lucent)
Bts commissioning (alcatel lucent)Bts commissioning (alcatel lucent)
Bts commissioning (alcatel lucent)Sayed Qaisar Shah
 
Mkt2014066467 en 9500mpr_microwave_backhaul_lte_appnote
Mkt2014066467 en 9500mpr_microwave_backhaul_lte_appnoteMkt2014066467 en 9500mpr_microwave_backhaul_lte_appnote
Mkt2014066467 en 9500mpr_microwave_backhaul_lte_appnoteOrlando Medina
 
Pa drive rack_manual_spanish
Pa drive rack_manual_spanishPa drive rack_manual_spanish
Pa drive rack_manual_spanishRoberts Discotec
 
3 g ibs walk test report dhk_v1415_tems
3 g ibs walk test report dhk_v1415_tems3 g ibs walk test report dhk_v1415_tems
3 g ibs walk test report dhk_v1415_temsIshaque uddin
 
Oss Bss Testing
Oss Bss TestingOss Bss Testing
Oss Bss TestingAhmed Adel
 

En vedette (14)

Alcate lucent bts Installation and Commissioning
Alcate lucent bts Installation and CommissioningAlcate lucent bts Installation and Commissioning
Alcate lucent bts Installation and Commissioning
 
Training report of Alcatel Lucent for 3G
Training report of Alcatel Lucent for 3GTraining report of Alcatel Lucent for 3G
Training report of Alcatel Lucent for 3G
 
Bts commissioning
Bts commissioningBts commissioning
Bts commissioning
 
Bts commissioning (alcatel lucent)
Bts commissioning (alcatel lucent)Bts commissioning (alcatel lucent)
Bts commissioning (alcatel lucent)
 
Estandar instalacion mpr v2.0
Estandar instalacion mpr v2.0Estandar instalacion mpr v2.0
Estandar instalacion mpr v2.0
 
Mkt2014066467 en 9500mpr_microwave_backhaul_lte_appnote
Mkt2014066467 en 9500mpr_microwave_backhaul_lte_appnoteMkt2014066467 en 9500mpr_microwave_backhaul_lte_appnote
Mkt2014066467 en 9500mpr_microwave_backhaul_lte_appnote
 
Pa drive rack_manual_spanish
Pa drive rack_manual_spanishPa drive rack_manual_spanish
Pa drive rack_manual_spanish
 
zafarresume
zafarresumezafarresume
zafarresume
 
3 g ibs walk test report dhk_v1415_tems
3 g ibs walk test report dhk_v1415_tems3 g ibs walk test report dhk_v1415_tems
3 g ibs walk test report dhk_v1415_tems
 
Ibs Rajeesh
Ibs RajeeshIbs Rajeesh
Ibs Rajeesh
 
Styles de management
Styles de managementStyles de management
Styles de management
 
Oss Bss Testing
Oss Bss TestingOss Bss Testing
Oss Bss Testing
 
IBS Training
IBS TrainingIBS Training
IBS Training
 
Telecom testing
Telecom testingTelecom testing
Telecom testing
 

Similaire à Mpr mss 1 c_user_manual (Alcatel Lucent)

Manual de Serviço BT 3000 Plus Ingles
Manual de Serviço BT 3000 Plus InglesManual de Serviço BT 3000 Plus Ingles
Manual de Serviço BT 3000 Plus InglesLucas Janiares
 
MSC(-S) R12 configuration (2).pdf
MSC(-S) R12 configuration (2).pdfMSC(-S) R12 configuration (2).pdf
MSC(-S) R12 configuration (2).pdfssuseraab3a8
 
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...f8iseoddm9i
 
JCB LK1 Personnel Platform (Supplement) Service Repair Manual.pdf
JCB LK1 Personnel Platform (Supplement) Service Repair Manual.pdfJCB LK1 Personnel Platform (Supplement) Service Repair Manual.pdf
JCB LK1 Personnel Platform (Supplement) Service Repair Manual.pdffyhsejkdm8u
 
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...ifkksem9didok
 
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...tan0033118
 
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...zao908wangsa
 
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...ukdkksmmd
 
KUBOTA U55-4 EXCAVATOR Service Repair Manual
KUBOTA U55-4 EXCAVATOR Service Repair ManualKUBOTA U55-4 EXCAVATOR Service Repair Manual
KUBOTA U55-4 EXCAVATOR Service Repair Manualukjemd ksjekm
 
Fanuc pmc programming manual
Fanuc pmc programming manualFanuc pmc programming manual
Fanuc pmc programming manualAntonio J
 
Manual GNSS GPS MSJ.pdf
Manual GNSS GPS MSJ.pdfManual GNSS GPS MSJ.pdf
Manual GNSS GPS MSJ.pdfsankal2
 
Tech note umts
Tech note umtsTech note umts
Tech note umtsMorg
 
Lcd samsung gnb23 mla gnb26mla_gnb32mla_gnb40mla_=_ln263r71bax__ln263r71wax__...
Lcd samsung gnb23 mla gnb26mla_gnb32mla_gnb40mla_=_ln263r71bax__ln263r71wax__...Lcd samsung gnb23 mla gnb26mla_gnb32mla_gnb40mla_=_ln263r71bax__ln263r71wax__...
Lcd samsung gnb23 mla gnb26mla_gnb32mla_gnb40mla_=_ln263r71bax__ln263r71wax__...BatistaBR
 
New Holland T4.55 T4.65 T4.75 Tractors (Pin.ELRT40HAN00001 and above) Operato...
New Holland T4.55 T4.65 T4.75 Tractors (Pin.ELRT40HAN00001 and above) Operato...New Holland T4.55 T4.65 T4.75 Tractors (Pin.ELRT40HAN00001 and above) Operato...
New Holland T4.55 T4.65 T4.75 Tractors (Pin.ELRT40HAN00001 and above) Operato...f8sjekkddmd3ed
 
New Holland T4.55 T4.65 T4.75 Tractors (Pin.ELRT40HAN00001 and above) Operato...
New Holland T4.55 T4.65 T4.75 Tractors (Pin.ELRT40HAN00001 and above) Operato...New Holland T4.55 T4.65 T4.75 Tractors (Pin.ELRT40HAN00001 and above) Operato...
New Holland T4.55 T4.65 T4.75 Tractors (Pin.ELRT40HAN00001 and above) Operato...fijksedmdmdm2w
 

Similaire à Mpr mss 1 c_user_manual (Alcatel Lucent) (20)

Manual de Serviço BT 3000 Plus Ingles
Manual de Serviço BT 3000 Plus InglesManual de Serviço BT 3000 Plus Ingles
Manual de Serviço BT 3000 Plus Ingles
 
TMP-3000 | Valve Actuators India
TMP-3000 | Valve Actuators IndiaTMP-3000 | Valve Actuators India
TMP-3000 | Valve Actuators India
 
Dse8620 operators-manual
Dse8620 operators-manualDse8620 operators-manual
Dse8620 operators-manual
 
MSC(-S) R12 configuration (2).pdf
MSC(-S) R12 configuration (2).pdfMSC(-S) R12 configuration (2).pdf
MSC(-S) R12 configuration (2).pdf
 
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
 
JCB LK1 Personnel Platform (Supplement) Service Repair Manual.pdf
JCB LK1 Personnel Platform (Supplement) Service Repair Manual.pdfJCB LK1 Personnel Platform (Supplement) Service Repair Manual.pdf
JCB LK1 Personnel Platform (Supplement) Service Repair Manual.pdf
 
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
 
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
 
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
 
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
JCB LK1 Personnel Platform (Supplement) Service Repair Manual Instant Downloa...
 
cablingstandard.pdf
cablingstandard.pdfcablingstandard.pdf
cablingstandard.pdf
 
ComPrep User Guide_v1
ComPrep User Guide_v1ComPrep User Guide_v1
ComPrep User Guide_v1
 
KUBOTA U55-4 EXCAVATOR Service Repair Manual
KUBOTA U55-4 EXCAVATOR Service Repair ManualKUBOTA U55-4 EXCAVATOR Service Repair Manual
KUBOTA U55-4 EXCAVATOR Service Repair Manual
 
Fanuc pmc programming manual
Fanuc pmc programming manualFanuc pmc programming manual
Fanuc pmc programming manual
 
Manual GNSS GPS MSJ.pdf
Manual GNSS GPS MSJ.pdfManual GNSS GPS MSJ.pdf
Manual GNSS GPS MSJ.pdf
 
Tech note umts
Tech note umtsTech note umts
Tech note umts
 
LTE_Overview_MTS EMERSON EDUARDO RODRIGUES
LTE_Overview_MTS EMERSON EDUARDO RODRIGUESLTE_Overview_MTS EMERSON EDUARDO RODRIGUES
LTE_Overview_MTS EMERSON EDUARDO RODRIGUES
 
Lcd samsung gnb23 mla gnb26mla_gnb32mla_gnb40mla_=_ln263r71bax__ln263r71wax__...
Lcd samsung gnb23 mla gnb26mla_gnb32mla_gnb40mla_=_ln263r71bax__ln263r71wax__...Lcd samsung gnb23 mla gnb26mla_gnb32mla_gnb40mla_=_ln263r71bax__ln263r71wax__...
Lcd samsung gnb23 mla gnb26mla_gnb32mla_gnb40mla_=_ln263r71bax__ln263r71wax__...
 
New Holland T4.55 T4.65 T4.75 Tractors (Pin.ELRT40HAN00001 and above) Operato...
New Holland T4.55 T4.65 T4.75 Tractors (Pin.ELRT40HAN00001 and above) Operato...New Holland T4.55 T4.65 T4.75 Tractors (Pin.ELRT40HAN00001 and above) Operato...
New Holland T4.55 T4.65 T4.75 Tractors (Pin.ELRT40HAN00001 and above) Operato...
 
New Holland T4.55 T4.65 T4.75 Tractors (Pin.ELRT40HAN00001 and above) Operato...
New Holland T4.55 T4.65 T4.75 Tractors (Pin.ELRT40HAN00001 and above) Operato...New Holland T4.55 T4.65 T4.75 Tractors (Pin.ELRT40HAN00001 and above) Operato...
New Holland T4.55 T4.65 T4.75 Tractors (Pin.ELRT40HAN00001 and above) Operato...
 

Dernier

Slack Application Development 101 Slides
Slack Application Development 101 SlidesSlack Application Development 101 Slides
Slack Application Development 101 Slidespraypatel2
 
Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Allon Mureinik
 
08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking MenDelhi Call girls
 
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure serviceWhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure servicePooja Nehwal
 
Human Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsHuman Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsMark Billinghurst
 
Understanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitectureUnderstanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitecturePixlogix Infotech
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerThousandEyes
 
Pigging Solutions Piggable Sweeping Elbows
Pigging Solutions Piggable Sweeping ElbowsPigging Solutions Piggable Sweeping Elbows
Pigging Solutions Piggable Sweeping ElbowsPigging Solutions
 
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking MenDelhi Call girls
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsMaria Levchenko
 
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxFactors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxKatpro Technologies
 
Breaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountBreaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountPuma Security, LLC
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)Gabriella Davis
 
Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationRadu Cotescu
 
Unblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen FramesUnblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen FramesSinan KOZAK
 
Swan(sea) Song – personal research during my six years at Swansea ... and bey...
Swan(sea) Song – personal research during my six years at Swansea ... and bey...Swan(sea) Song – personal research during my six years at Swansea ... and bey...
Swan(sea) Song – personal research during my six years at Swansea ... and bey...Alan Dix
 
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersEnhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersThousandEyes
 
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 3652toLead Limited
 
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024BookNet Canada
 
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | DelhiFULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhisoniya singh
 

Dernier (20)

Slack Application Development 101 Slides
Slack Application Development 101 SlidesSlack Application Development 101 Slides
Slack Application Development 101 Slides
 
Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)
 
08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men
 
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure serviceWhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
 
Human Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsHuman Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR Systems
 
Understanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitectureUnderstanding the Laravel MVC Architecture
Understanding the Laravel MVC Architecture
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected Worker
 
Pigging Solutions Piggable Sweeping Elbows
Pigging Solutions Piggable Sweeping ElbowsPigging Solutions Piggable Sweeping Elbows
Pigging Solutions Piggable Sweeping Elbows
 
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed texts
 
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxFactors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
 
Breaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountBreaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path Mount
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)
 
Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organization
 
Unblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen FramesUnblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen Frames
 
Swan(sea) Song – personal research during my six years at Swansea ... and bey...
Swan(sea) Song – personal research during my six years at Swansea ... and bey...Swan(sea) Song – personal research during my six years at Swansea ... and bey...
Swan(sea) Song – personal research during my six years at Swansea ... and bey...
 
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersEnhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
 
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
 
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
 
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | DelhiFULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
 

Mpr mss 1 c_user_manual (Alcatel Lucent)

  • 1. User Manual Indoor: MSS-1c + Outdoor: MPT-HC/MPT-MC 9500 MPR-E 3DB 18782 AAAA Issue 1 Rel. 2.2.0 October 2010
  • 2. Status: RELEASED All rights reserved. Passing on and copying of this document, use and communication of its contents is not permitted without written authorization from Alcatel-Lucent. 3DB 18782 AAAA Issue 1 Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners. The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein. Copyright © 2010 Alcatel-Lucent
  • 3. User Manual Table of Contents 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 1/308 TABLE OF CONTENTS LIST OF FIGURES ......................................................................................................................... 5 LIST OF TABLES ........................................................................................................................... 9 PREFACE......................................................................................................................................... 11 Preliminary Information.............................................................................................................. 11 Applicability................................................................................................................................. 12 Scope ........................................................................................................................................... 12 History.......................................................................................................................................... 12 Change notes .............................................................................................................................. 13 Handbook Structure ................................................................................................................... 13 General on Alcatel-Lucent Customer Documentation ............................................................ 14 1 SAFETY, EMC, EMF, ESD NORMS AND EQUIPMENT LABELLING ........................................ 19 1.1 Declaration of conformity to CE marking and Countries List ......................................... 20 1.2 Specific label for MPR equipment...................................................................................... 21 1.3 Applicable standards and recommendations ................................................................... 21 1.4 Safety Rules ......................................................................................................................... 22 1.4.1 General Rules................................................................................................................. 22 1.4.2 Labels Indicating Danger, Forbiddance, Command........................................................ 23 1.5 Electromagnetic Compatibility (EMC norms).................................................................... 26 1.6 Equipment protection against electrostatic discharges .................................................. 27 1.7 Cautions to avoid equipment damage............................................................................... 28 2 PRODUCT INFORMATION AND PLANNING ............................................................................. 29 2.1 9500 Family overview .......................................................................................................... 31 2.1.1 9500 MPR System Family .............................................................................................. 35 2.1.2 Family elements described in this User Manual ............................................................. 36 2.1.3 MSS-1c ........................................................................................................................... 36 2.1.4 MPT-HC .......................................................................................................................... 37 2.1.5 MPT-MC.......................................................................................................................... 37 2.1.6 MSS-1c to MPT-HC interconnection............................................................................... 38 2.1.7 MSS-1c to MPT-MC interconnection............................................................................... 40 2.1.8 Antennas......................................................................................................................... 40 2.2 Radio capacity, channelling and modulation (MPT-HC/MPT-MC).................................... 41 2.3 Standard Features ............................................................................................................... 44 2.4 Radio Configurations .......................................................................................................... 44 2.5 Typical System Configurations .......................................................................................... 45 2.6 Environmental and Electrical Characteristics................................................................... 46 2.6.1 General characteristics (MSS-1c)................................................................................... 46 2.6.2 General characteristics (MPT-HC/MPT-MC)................................................................... 47 2.6.3 MPT-MC characteristics.................................................................................................. 48 2.6.4 MPT-HC characteristics .................................................................................................. 49 2.6.5 Radio performances ....................................................................................................... 49 2.6.6 General characteristics (Power Extractor) ...................................................................... 50 2.7 Parts Lists............................................................................................................................. 51 2.7.1 MSS-1c ........................................................................................................................... 51 2.7.2 MPT-HC optical interface option ..................................................................................... 51 2.7.3 MPT-HC with internal diplexer ........................................................................................ 52 2.7.4 MPT-MC with internal diplexer........................................................................................ 54 2.7.5 MPT-HC/MPT-MC with external diplexer (7/8 GHz)........................................................ 56 2.8 Functional description ........................................................................................................ 59 2.8.1 MSS-1c (Indoor Unit) ...................................................................................................... 59
  • 4. User Manual Table of Contents 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 12/308 2.8.2 Fan unit........................................................................................................................... 63 2.8.3 MPT-HC .......................................................................................................................... 64 2.8.4 Power Extractor .............................................................................................................. 73 2.8.5 MPT-MC.......................................................................................................................... 74 2.8.6 Radio Transmission Features with MPT-HC/MPT-MC.................................................... 75 2.8.7 TMN communication channels ....................................................................................... 78 2.8.8 Traffic profiles ................................................................................................................. 79 2.8.9 Ethernet Traffic Management ......................................................................................... 84 2.8.10 Quality Of Services (QoS) ............................................................................................ 85 2.8.11 Cross-connections ........................................................................................................ 89 2.8.12 Synchronization ............................................................................................................ 91 3 NE MANAGEMENT BY SOFTWARE APPLICATION................................................................. 95 3.1 WebEML start ....................................................................................................................... 95 3.2 Tool bar................................................................................................................................. 97 3.3 Alarm Synthesis................................................................................................................... 98 3.4 Domain Alarm Synthesis Area............................................................................................ 98 3.5 General Information on the Management State ................................................................ 99 3.6 Navigator area...................................................................................................................... 100 3.6.1 Commissioning ............................................................................................................... 101 3.6.2 Performance Monitoring ................................................................................................. 117 3.6.3 Troubleshooting .............................................................................................................. 126 3.6.4 Maintenance ................................................................................................................... 128 3.6.5 Monitoring ....................................................................................................................... 129 3.6.6 Provisioning Tool............................................................................................................. 135 4 INSTALLATION............................................................................................................................ 149 4.1 Installation & Interconnection overview ............................................................................ 149 4.2 Hardware Installation........................................................................................................... 151 4.2.1 Power consumption ........................................................................................................ 151 4.2.2 Rack Installation ............................................................................................................. 152 4.2.3 MSS-1c installation ......................................................................................................... 162 4.2.4 MPT-HC Installation........................................................................................................ 168 4.2.5 MPT-MC Installation........................................................................................................ 208 4.2.6 Power Extractor .............................................................................................................. 228 4.2.7 Indoor Installation ........................................................................................................... 229 4.2.8 Antenna Alignment ......................................................................................................... 237 4.3 Software local copy ............................................................................................................. 246 4.3.1 Getting Started................................................................................................................ 247 4.3.2 PC Characteristics .......................................................................................................... 247 4.3.3 Local copy of the Software Package (SWP) to the PC................................................... 248 4.3.4 Local copy the WebEML to PC....................................................................................... 250 4.3.5 Configure PC Network Card to Connect to NE............................................................... 256 5 PROVISIONING............................................................................................................................ 259 6 MAINTENANCE AND TROUBLE-CLEARING ............................................................................ 263 6.1 Introduction.......................................................................................................................... 263 6.2 Maintenance Philosophy..................................................................................................... 264 6.3 Personal Computer (PC)/Laptop ........................................................................................ 264 6.4 Troubleshooting................................................................................................................... 264 6.4.1 Before Going to Site Checklist........................................................................................ 264 6.4.2 PC Troubleshooting ........................................................................................................ 265 6.4.3 Troubleshooting Basics................................................................................................... 265 6.4.4 Troubleshooting with MSS-1c electrical or optical connection........................................ 271
  • 5. User Manual Table of Contents 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 3/308 6.4.5 Troubleshooting Path Problems...................................................................................... 271 6.4.6 Troubleshooting Configuration Problems........................................................................ 273 6.4.7 Troubleshooting Ethernet Problems ............................................................................... 273 6.4.8 Troubleshooting TMN Problems ..................................................................................... 274 6.5 Failed equipment removal and replacement..................................................................... 276 6.5.1 MSS-1c removal and replacement ................................................................................. 276 6.5.2 MPT-HC removal and replacement................................................................................. 276 6.5.3 MPT-MC removal and replacement ................................................................................ 276 6.6 Cleaning................................................................................................................................ 277 7 LINE–UP AND COMMISSIONING............................................................................................... 279 7.1 Introduction.......................................................................................................................... 280 7.1.1 General ........................................................................................................................... 280 7.1.2 Safety–EMC–EMF–ESD norms and cautions to avoid equipment damage................... 281 7.1.3 Conventions.................................................................................................................... 281 7.1.4 Summary of the line–up, commissioning, and acceptance phases ................................ 282 7.1.5 How to access the remote NE ........................................................................................ 283 7.2 Commissioning of STATION A – phase 1 (Turn up).......................................................... 284 7.2.1 Turn–on preliminary operations ...................................................................................... 284 7.2.2 Powering up the MSS-1c(s) with ODU(s) connected...................................................... 285 7.3 Commissioning of STATION B – phase 1 (Turn up).......................................................... 285 7.4 Fine antenna alignment and preliminary checks – Stations A & B................................. 285 7.4.1 Fine antenna alignment .................................................................................................. 285 7.4.2 Preliminary checks.......................................................................................................... 286 7.5 End of commissioning phase 1 (Turn up) in STATION A ................................................. 287 7.6 Commissioning station A – phase 2 (acceptance test).................................................... 288 7.6.1 Installation and cabling visual inspection........................................................................ 290 7.6.2 System configuration ...................................................................................................... 290 7.6.3 E1 traffic.......................................................................................................................... 292 7.6.4 Ethernet traffic................................................................................................................. 293 7.6.5 NE configuration ............................................................................................................. 293 7.6.6 Data/Time settings .......................................................................................................... 294 7.6.7 Hop E1 stability test ........................................................................................................ 294 7.6.8 Ethernet Traffic stability test............................................................................................ 295 7.7 Commissioning station B – Phase 2 (acceptance Test)................................................... 299 7.8 Final operations ................................................................................................................... 299 7.9 Annex A: fine antenna alignment....................................................................................... 299 ABBREVIATIONS ............................................................................................................................ 301 CUSTOMER DOCUMENTATION FEEDBACK.............................................................................. 307
  • 6. User Manual Table of Contents 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 14/308
  • 7. User Manual List of Figures 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 5/308 LIST OF FIGURES Figure 1. Multiservice Aggregation Layer ......................................................................................... 33 Figure 2. Service Awareness ............................................................................................................ 33 Figure 3. Packet Node ...................................................................................................................... 34 Figure 4. Service-driven Packet Adaptive Modulation ...................................................................... 34 Figure 5. 9500 MPR System Family ................................................................................................. 35 Figure 6. MPT-HC ............................................................................................................................. 37 Figure 7. MPT-MC............................................................................................................................. 37 Figure 8. MPT-HC connection (electrical cable) ............................................................................... 38 Figure 9. MPT-HC connection (optical cable + power supply cable to MSS-1c)............................... 39 Figure 10. MPT-HC connection (optical cable + power supply cable to Station battery) .................. 39 Figure 11. MPT-MC connection......................................................................................................... 40 Figure 12. TDM Over Ethernet Packet Node - Mapping of 10 E1 TDM on Ethernet ........................ 45 Figure 13. TDM and Ethernet Terminal Packet Transport 10 E1 TDM and 1 Radio Direction.......... 45 Figure 14. MSS-1c block diagram..................................................................................................... 59 Figure 15. MSS-1c front view............................................................................................................ 60 Figure 16. MSS-1c rear view ............................................................................................................ 60 Figure 17. MSS-1c and Fan unit....................................................................................................... 63 Figure 18. MPT system..................................................................................................................... 65 Figure 19. 11-38 GHz MPT-HC housing ........................................................................................... 65 Figure 20. 6 GHz MPT-HC housing .................................................................................................. 65 Figure 21. 7-8 GHz MPT-HC housing ............................................................................................... 66 Figure 22. MPT-HC block diagram.................................................................................................... 66 Figure 23. 7/8 GHz MPT-HC architecture ......................................................................................... 69 Figure 24. 11 to 38 GHz MPT-HC architecture ................................................................................. 69 Figure 25. Power Extractor ............................................................................................................... 73 Figure 26. 6 GHz and from 11 to 38 GHz MPT-MC housing............................................................. 74 Figure 27. 7-8 GHz MPT-MC housing............................................................................................... 75 Figure 28. Available loopbacks ......................................................................................................... 77 Figure 29. Traffic profiles .................................................................................................................. 79 Figure 30. Traffic profiles .................................................................................................................. 80 Figure 31. E1 Traffic.......................................................................................................................... 81 Figure 32. E1 Traffic.......................................................................................................................... 82 Figure 33. E1 Traffic.......................................................................................................................... 83 Figure 34. QoS in the MSS-1c.......................................................................................................... 85 Figure 35. QoS in the MPT ............................................................................................................... 87 Figure 36. Cross-connection............................................................................................................. 89 Figure 37. E1 from/to Radio port....................................................................................................... 89 Figure 38. E1 from/to Ethernet port .................................................................................................. 90 Figure 39. Main view: System Overview........................................................................................... 97 Figure 40. Inventory.......................................................................................................................... 101 Figure 41. Software Download: Software Package versions ............................................................ 102 Figure 42. Software download .......................................................................................................... 103 Figure 43. Software Download: Active Software Package summary................................................ 103 Figure 44. Software Download: Stand-by Software Package summary............................................ 104 Figure 45. Date/Time Configuration.................................................................................................. 105 Figure 46. Site Information................................................................................................................ 106 Figure 47. Protection Configuration .................................................................................................. 106 Figure 48. Radio Configuration: FCM - RTPC .................................................................................. 109 Figure 49. Radio Configuration: FCM - ATPC................................................................................... 109 Figure 50. Radio Configuration: ACM - RTPC .................................................................................. 110 Figure 51. Advanced Radio Configuration........................................................................................ 110 Figure 52. MSS-1c Configuration...................................................................................................... 111
  • 8. User Manual List of Figures 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 16/308 Figure 53. FTP Server Parameters................................................................................................... 112 Figure 54. Network Interfaces........................................................................................................... 113 Figure 55. Static Routing................................................................................................................... 114 Figure 56. Trusted SNMP Managers ................................................................................................ 115 Figure 57. Manager registration........................................................................................................ 115 Figure 58. Backup / Restore ............................................................................................................. 116 Figure 59. Performance History File Upload..................................................................................... 118 Figure 60. Counter Thresholds ......................................................................................................... 118 Figure 61. 15Min Counter activation................................................................................................. 119 Figure 62. 15Min Counter ................................................................................................................. 119 Figure 63. 15Min Counter history...................................................................................................... 120 Figure 64. 15Min Counter deactivation............................................................................................. 120 Figure 65. Adaptive Modulation counter activation........................................................................... 121 Figure 66. 15Min Counter ................................................................................................................. 122 Figure 67. 15Min Counter history...................................................................................................... 122 Figure 68. 15Min Counter deactivation............................................................................................. 123 Figure 69. Ethernet: Qos Counters................................................................................................... 124 Figure 70. Qos Counters example for Aggregate ............................................................................. 125 Figure 71. Inventory.......................................................................................................................... 126 Figure 72. Loopback activation......................................................................................................... 127 Figure 73. ACM Manual Management.............................................................................................. 127 Figure 74. Maintenance .................................................................................................................... 128 Figure 75. Alarms.............................................................................................................................. 130 Figure 76. Power measurements...................................................................................................... 130 Figure 77. Power measurements...................................................................................................... 131 Figure 78. Modem measurements .................................................................................................... 132 Figure 79. Modem measurements .................................................................................................... 133 Figure 80. Events.............................................................................................................................. 134 Figure 81. Provisioning Tool: Welcome screen................................................................................. 135 Figure 82. Ethernet ports provisioning .............................................................................................. 136 Figure 83. Cross connection TDM2TDM .......................................................................................... 138 Figure 84. One shot tributaries configuration.................................................................................... 138 Figure 85. Cross connection functional scheme............................................................................... 139 Figure 86. Cross connection to user Ethernet port ........................................................................... 140 Figure 87. Cross connection functional scheme............................................................................... 141 Figure 88. Management port provisioning ........................................................................................ 142 Figure 89. TDM cross connection between radio and Ethernet port................................................. 143 Figure 90. Cross connection functional scheme............................................................................... 144 Figure 91. Network Synchronization Clock provisioning................................................................... 144 Figure 92. NE bridge mode selection................................................................................................ 145 Figure 93. Port VLAN provisioning.................................................................................................... 146 Figure 94. Station interconnections with MPT-MC ............................................................................ 149 Figure 95. Station interconnections with MPT-HC with Power Extractor........................................... 149 Figure 96. Station interconnections with MPT-HC (optical cable + coax. power supply cable to MSS-1c)............................................................................................... 150 Figure 97. Station interconnections with MPT-HC (optical cable + coax. power supply cable to Station battery) .................................................................................... 150 Figure 98. Fixing the Rack to Floor (1) ............................................................................................. 153 Figure 99. Fixing the Rack to Floor (2) ............................................................................................. 154 Figure 100. Floor file drilling template............................................................................................... 155 Figure 101. Example of securing rack assembly to computer floor .................................................. 156 Figure 102. Laborack........................................................................................................................ 157 Figure 103. Top Rack Unit (T.R.U.)................................................................................................... 158 Figure 104. Top Rack Unit - Front/Rear............................................................................................ 158
  • 9. User Manual List of Figures 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 7/308 Figure 105. Top Rack Unit - Fixed to rack......................................................................................... 158 Figure 106. TRU Connections .......................................................................................................... 160 Figure 107. TRU Grounding position on Laborack ........................................................................... 160 Figure 108. ETSI Rack - Ground connection.................................................................................... 161 Figure 109. Laborack - Ground connection ...................................................................................... 161 Figure 110. Grounding ...................................................................................................................... 163 Figure 111. Grounding....................................................................................................................... 163 Figure 112. Power supply connector................................................................................................. 163 Figure 113. Installation solution......................................................................................................... 164 Figure 114. Installation solution......................................................................................................... 164 Figure 115. Installation solution......................................................................................................... 165 Figure 116. Interconnections to connector support 1.6/5.6 75 ohm Panel 1U (3CC08061AAAA).... 165 Figure 117. Interconnections to connector support BNC 75 ohm Panel 1U (3CC08061ABAA) ....... 166 Figure 118. Interconnections to support 19 Inch modules 120 ohm Panel 3U (3CC07810AAAA) ... 166 Figure 119. ....................................................................................................................................... 167 Figure 120. ....................................................................................................................................... 167 Figure 121. Views of MPT-HC with embedded diplexer (11-38 GHz) ............................................... 169 Figure 122. Views of MPT-HC with embedded diplexer (6 GHz)...................................................... 170 Figure 123. Views of MPT-HC with external diplexer (7 GHz and 8 GHz)........................................ 170 Figure 124. Views of MPT-HC with embedded diplexer (11-38 GHz) ............................................... 172 Figure 125. Views of MPT-HC with external diplexer (7 GHz and 8 GHz)........................................ 173 Figure 126. Views of MPT-HC with embedded diplexer (6 GHz)...................................................... 174 Figure 127. Composition of MPT-HC with external diplexer ............................................................. 175 Figure 128. MPT-HC TRANSCEIVER and BRANCHING boxes coupling surfaces ......................... 176 Figure 129. 6-7-8 GHz MPT-HC BRANCHING box mistake-proofing............................................... 176 Figure 130. Label affixed on the MPT-HC and MPT-HC TRANSCEIVER box.................................. 177 Figure 131. Label affixed inside the MPT-HC BRANCHING box...................................................... 178 Figure 132. Example of integrated antenna Pole Mounting (with antenna and nose adapter) ...................................................................................................... 181 Figure 133. "Pole Mounting for Remote ODU" Installation kit (3DB10137AAXX)............................ 182 Figure 134. Example of antenna polarization change (“1+0” MPT-HC integrated antenna)............. 183 Figure 135. Putting silicone grease on O-ring before MPT-HC insertion .......................................... 184 Figure 136. MPT-HC 1+0 installation for integrated antenna (11-38 GHz) ....................................... 184 Figure 137. MPT-HC 1+0 installation for integrated antenna (6-7-8 GHz: vertical polarization) ....... 185 Figure 138. MPT-HC 1+0 installation for integrated antenna (6-7-8 GHz: horizontal polarization)... 185 Figure 139. "Pole Mounting for Remote ODU" installation................................................................ 186 Figure 140. Putting silicone grease on O-ring before MPT-HC insertion .......................................... 186 Figure 141. MPT-HC 1+0 installation for not integrated antenna (11-38 GHz with pole mounting P/N 3DB 10137 AAAB) ..................................................................................................................... 187 Figure 142. MPT-HC 1+0 installation for not integrated antenna (6-7-8 GHz with pole mounting P/N 3DB10137AAXX) ....................................................................................................................... 187 Figure 143. Locations for Cable Grounds......................................................................................... 204 Figure 144. Views of MPT-MC with embedded diplexer (6 and 11-38 GHz)..................................... 209 Figure 145. Views of MPT-MC with external diplexer (7 GHz and 8 GHz)........................................ 210 Figure 146. Views of MPT-MC with embedded diplexer (6 and 11-38 GHz)..................................... 211 Figure 147. Views of MPT-MC with external diplexer (7 GHz and 8 GHz)........................................ 211 Figure 148. Composition of MPT-MC with external diplexer............................................................. 212 Figure 149. MPT-MC TRANSCEIVER and BRANCHING boxes coupling surfaces......................... 213 Figure 150. 7-8 GHz MPT-MC BRANCHING box mistake-proofing ................................................. 214 Figure 151. Label affixed on the MPT-MC and MPT-MC TRANSCEIVER box................................. 215 Figure 152. Label affixed inside the MPT-MC BRANCHING box...................................................... 216 Figure 153. Example of antenna polarization change (“1+0” MPT-MC integrated antenna)............. 219 Figure 154. Putting silicone grease on O-ring before MPT-MC insertion.......................................... 220 Figure 155. MPT-MC 1+0 installation for integrated antenna (6 GHz and 11-38 GHz)..................... 220
  • 10. User Manual List of Figures 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 18/308 Figure 156. MPT-MC 1+0 installation for integrated antenna (7-8 GHz: vertical polarization).......... 221 Figure 157. MPT-MC 1+0 installation for integrated antenna (7-8 GHz: horizontal polarization)...... 221 Figure 158. "Pole Mounting for Remote ODU" installation................................................................ 222 Figure 159. Putting silicone grease on O-ring before MPT-MC insertion.......................................... 222 Figure 160. MPT-MC 1+0 installation for not integrated antenna (with pole mounting P/N 3DB 10137 AAAB) ..................................................................................................................... 223 Figure 161. Short kit plug R2CT ....................................................................................................... 224 Figure 162. Short kit plug R2CT items.............................................................................................. 224 Figure 163. MPT/AWY Service Cord ................................................................................................ 239 Figure 164. Checking Feedhead Flange with a Spirit level............................................................... 242 Figure 165. Indicative head-on signal pattern for a parabolic antenna ............................................. 244 Figure 166. Example Tracking Path Signals..................................................................................... 245 Figure 167. Example Tracking Path Signals on the First Side Lobe................................................. 245 Figure 168. PC connection ............................................................................................................... 259 Figure 169. Relative positions of stations A and B ........................................................................... 281 Figure 170. Test bench for tributary functionality check with MPT-HC/MPT-MC............................... 292 Figure 171. Test bench for tributary functionality check with MPT-HC/MPT-MC............................... 294 Figure 172. Test bench for optional Ethernet Data Channel functionality with 1 additional PC and 1 Ethernet cable................................................................................................................................... 296 Figure 173. Test bench for optional Ethernet Data Channel functionality with 2 additional PCs ..... 297 Figure 174. Test bench for optional Ethernet Data Channel functionality with 2 Ethernet Data Analyzers ................................................................................................................ 298
  • 11. User Manual List of Tables 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 9/308 LIST OF TABLES Table 1. Radio capacity, channelling scheme and modulation (Static Modulation)........................... 41 Table 2. Radio capacity, channelling scheme and modulation (Adaptive Modulation)...................... 43 Table 3. MSS-1c item codes ............................................................................................................. 51 Table 4. CD-ROM Software codes.................................................................................................... 51 Table 5. MPT-HC option.................................................................................................................... 51 Table 6. MPT-HC codes with internal diplexer .................................................................................. 52 Table 7. MPT-MC codes with internal diplexer.................................................................................. 54 Table 8. 7 GHz MPT-MC codes with external diplexer...................................................................... 56 Table 9. 7 GHz MPT-HC codes with external diplexer ...................................................................... 56 Table 10. 7 GHz Branching assemblies (for MPT-HC and MPT-MC)................................................ 57 Table 11. 8 GHz MPT-MC codes with external diplexer.................................................................... 58 Table 12. 8 GHz MPT-HC codes with external diplexer .................................................................... 58 Table 13. 8 GHz Branching assemblies (for MPT-HC and MPT-MC)................................................ 58 Table 14. RSSI Table ........................................................................................................................ 72 Table 15. Waveguide Flange Data.................................................................................................... 72 Table 16. MPT-HC external interfaces ............................................................................................. 171 Table 17. RF interface...................................................................................................................... 171 Table 18. MPT-HC Output flanges with external antenna ................................................................. 201 Table 19. 6-7-8GHz Flextwist waveguide.......................................................................................... 202 Table 20. 11-38GHz Flextwist waveguide ......................................................................................... 202 Table 21. MPT-MC external interfaces............................................................................................. 210 Table 22. RF interface...................................................................................................................... 210 Table 23. Pin Function: Tributaries 1- 8 ............................................................................................ 235 Table 24. Pin Function: Tributaries 9- 10 .......................................................................................... 236 Table 25. MSS-1c and Fans Alarm Matrix ........................................................................................ 266 Table 26. MPT-HC Alarm Matrix ....................................................................................................... 267 Table 27. MPT-MC Alarm Matrix ....................................................................................................... 269 Table 28. TMN Network Troubleshooting ........................................................................................ 274 Table 29. Test and commissioning instruments ................................................................................ 280
  • 12. User Manual List of Tables 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 110/308
  • 13. User Manual Preface 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 11/308 PREFACE Preliminary Information WARRANTY Any warranty must be referred exclusively to the terms of the contract of sale of the equipment to which this handbook refers to. Alcatel–Lucent makes no warranty of any kind with regards to this manual, and specifically disclaims the implied warranties of merchantability and fitness for a particular purpose. Alcatel–Lucent will not be liable for errors contained herein or for damages, whether direct, indirect, consequential, inci- dental, or special, in connection with the furnishing, performance, or use of this material. INFORMATION The product specification and/or performance levels contained in this document are for information purposes only and are subject to change without notice. They do not represent any obligation on the part of Alcatel–Lucent. COPYRIGHT NOTIFICATION The technical information of this manual is the property of Alcatel–Lucent and must not be copied, reproduced or disclosed to a third party without written consent. SAFETY RECOMMENDATIONS The safety recommendations here below must be considered to avoid injuries on persons and/or damage to the equipment: 1) Service Personnel Installation and service must be carried out by authorized persons having appropriate technical training and experience necessary to be aware of hazardous operations during installation and service, so as to prevent any personal injury or danger to other persons, as well as prevent- damaging the equipment. 2) Access to the Equipment Access to the Equipment in use must be restricted to Service Personnel only. 3) Safety Rules Recommended safety rules are indicated in Chapter 1 from page 19.
  • 14. User Manual Preface 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 112/308 Local safety regulations must be used if mandatory. Safety instructions in this handbook should be used in addition to the local safety regulations. In case of conflict between safety instructions stated in this manual and those indicated in local regulations, mandatory local norms will pre- vail. Should not local regulations be mandatory, then safety rules stated in this manual will pre- vail. SERVICE PERSONNEL SKILL Service Personnel must have an adequate technical background on telecommunications and in par- ticular on the equipment subject of this handbook. An adequate background is required to properly install, operate and maintain equipment. The fact of merely reading this handbook is considered as not enough. Applicability This handbook applies to the following product–release: PRODUCT 9500 MPR-E PRODUCT RELEASE MSS-1c/MPT-HC/MPT-MC 2.2.0 Scope This document aims to describe the hardware and software functionalities of the 9500 MPR MPT-Access. This document is intended to the technicians involved in Planning, in Operation and Maintenance and in Commissioning of the 9500 MPR MPT-Access. History ISSUE DATE DESCRIPTIONS 01 October 2010
  • 15. User Manual Preface 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 13/308 Change notes Handbook Structure This handbook has been edited according to the Alcatel-Lucent standardized “drawing-up guides" com- plying with such suggestion. This handbook is divided into the main topics described in the table of contents: PREFACE It contains general information as preliminary information, hand- book scope, history. Furthermore, it describes the handbook struc- ture and the customer documentation. SAFETY This section includes all the safety instructions. PRODUCT INFORMATION AND PLANNING This section provides the equipment description (at system, MSS- 1c and Outdoor levels), introduces the basic information regarding the HW architecture, and gives its technical characteristics. NE MANAGEMENT BY SOFTWARE APPLICATIONS This section gives the description and use of the SW tools available for the NE management. INSTALLATION This section provides whole information regarding Equipment hard- ware installation. Moreover, it contains the whole operative information on: – provisioning of equipment items (P/Ns, equipping rules) – their physical position in the system – unit assembly and front panel drawings, with the description on the access point usage (connectors, visual indicators, but- tons). This section provides also the whole operative instructions for the preparation of the Craft Terminal for the Line–Up and Commission- ing of the two NEs making up the radio link. PROVISIONING This section gives all the instructions to provision (to configure) the NE. MAINTENANCE AND TROUBLE-CLEARING This section contains the whole logical and operative information for the equipment maintenance and system upgrade. LINE-UP AND COMMISSIONING This section provides all the instructions for the line-up and com- missioning of the NE. ABBREVIATIONS The abbreviation list is supplied. CUSTOMER DOCUMENTA- TION FEEDBACK It contains info regarding customer opinions collection about this documentation.
  • 16. User Manual Preface 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 114/308 General on Alcatel-Lucent Customer Documentation This paragraph describes in general the Alcatel–Lucent Customer Documentation system, details the association between the product levels and the associated documentation, and explains Customer Doc- umentation characteristics as well as the policies for its delivery and updating. Customer–Independent Standard Customer Documentation a) Definition Standard Customer Documentation, referred to hereafter, must be always meant as plant–indepen- dent and is always independent of any Customization. Plant–dependent and/or Customized documentation, if envisaged by the contract, is subjected to commercial criteria as far as contents, formats and supply conditions are concerned. N.B. Plant–dependent and Customized documentation is not described here. b) Aims of standard Customer Documentation Standard system, hardware and software documentation is meant to give the Customer personnel the possibility and the information necessary for installing, commissioning, operating, and maintain- ing the equipment according to Alcatel–Lucent Laboratory design and Installation Dept. choices. In particular: • the contents of the chapters associated to the software applications focus on the explanation of the man–machine interface and of the operating procedures allowed by it; • maintenance is described down to faulty PCB location and replacement. N.B. No supply to Customers of design documentation (like PCB hardware design andproduction documents and files, software source programs, programming tools, etc.) is envisaged. Product levels and associated Customer Documentation a) Products A “product” is defined by the network hierarchical level where it can be inserted and by the whole of performances and services that it is meant for. E.g. 9500 MPR is a product. b) Product-releases A ”product” evolves through successive “product–releases”, which are the real products marketed for their delivery at a certain ”product–release” availability date. A certain ”product–release” performs more functionalities than the previous one. E.g. Rel.1.0 and Rel.2.0 are two successive “product–releases” of the same “product”. A “product–release” comprehends a set of hardware components and at least one “Software Pack- age” (SWP); as a whole, they identify the possible network applications and the equipment perfor- mances that the specific “product–release” has been designed, engineered, and marketed for. c) Configurations and Network Elements In some cases, a “product–release” includes different possible “configurations” which are distin- guished from one another by different “Network Element” (NE) types and, from the management point of view, by different SWPs. d) SWP releases, versions, and CD–ROMs • Each SWP is distributed by means of a specific SWP CD–ROM. • A SWP is identified by its “Denomination”, “P/N” (Part Number) and “CS” (Change Status), that are printed on the CD–ROM’s label: – the first and second digits of the “Denomination” (e.g. 2.0) correspond to the “HW product– release” number; – the third digit of the of the “Denomination” (e.g. 2.0.2) identifies the Version Level of the SWP.
  • 17. User Manual Preface 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 15/308 • A SWP with new Version Level, providing main features in addition to those of the previous Ver- sion Level SWP, is distributed by means of a SWP CD–ROM having new “Denomination”,“P/ N” (Part Number), and “CS” restarting from 01 • A SWP patch version, if any, is created to correct SW bugs, and/or to add minor features, andis distributed by means of a SWP CD–ROM, that can be identified: – by the same “P/N” of the former CD–ROM, but with an incremented “CS” number (e.g.CS=02 instead of previous CS=01) – or by a new “P/N”, and “CS” restarting from 01. Handbook Updating The handbooks associated to the "product-release" are listed in “History“ on page 12. Each handbook is identified by: – the name of the "product–release" (and "version" when the handbook is applicable to the versions starting from it, but not to the previous ones), – the handbook name, – the handbook Part Number, – the handbook edition (usually first edition=01), – the handbook issue date. The date on the handbook does not refer to the date of print but to the date on which the handbook source file has been completed and released for the production. Changes introduced in the same product–release (same handbook P/N) The edition and date of issue might change on future handbook versions for the following reasons: – only the date changes (pointed out in the Table of Contents) when modifications are made to the edi- torial system not changing the technical contents of the handbook. – the edition, hence the date, is changed because modifications made concern technical contents. In this case: • the changes with respect to the previous edition are listed in “History” on page 12; • in affected chapters, revision bars on the left of the page indicate modifications in text and draw- ings. Changes concerning the technical contents of the handbook cause the edition number increase (e.g. from Ed.01 to Ed.02). Slight changes (e.g. for corrections) maintain the same edition but with the addition of a version character (e.g. from Ed.02 to Ed.02A). Version character can be used for draft or proposal edi- tions. NOTES FOR HANDBOOKS RELEVANT TO SOFTWARE APPLICATIONS Handbooks relevant to software applications (typically the Operator's Handbooks) are not modified unless the new software "version" distributed to Customers implies man-machine interface changes or in case of slight modifications not affecting the understanding of the explained procedures. Moreover, should the screen prints included in the handbook contain the product–release's "version" marking, they are not replaced in the handbooks related to a subsequent version, if the screen contents are unchanged. Supplying updated handbooks to Customers Supplying updated handbooks to Customers who have already received previous issues is submitted to commercial criteria. By updated handbook delivery it is meant the supply of a complete copy of the handbook new issue (sup- plying errata-corrige sheets is not envisaged).
  • 18. User Manual Preface 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 116/308 Changes due to new product version A new product version changes the handbook P/N and the edition starts from 01. In this case the modified parts of the handbook are not listed. Customer documentation on CD-ROM In the following by 'CD-ROM' it is meant 'Customer Documentation on CD-ROM' Contents, creation and production of a CD-ROM In most cases, a CD-ROM contains in read-only eletronic format the documentation of one product- release(-version) and for a certain language. In some other cases, the same CD-ROM can contain the documentation of different product-release(-ver- sion)s for a certain language. As a general rule: – CD-ROMs for Network Management products do not contain: • the Installation Guides • the documentation of system optional features that Customers could not buy from Alcatel- Lucent together with the main applicative SW. – CD-ROMs for Network Elements products do not contain: • the documentation of system optional features (e.g. System Installation Handbooks related to racks that Customers could not buy from Alcatel-Lucent together with the main equipment). A CD-ROM is obtained collecting various handbooks and documents in .pdf format. Bookmarks and hyperlinks make the navigation easier. No additional information is added to each handbook, so that the documentation present in the CD-ROMs is exactly the same the Customer would receive on paper. The files processed in this way are added to files/images for managing purpose and a master CD-ROM is recorded. Suitable checks are made in order to have a virus-free product. After a complete functional check, the CD-ROM image is electronically transferred to the archive of the Production Department, so that the CD-ROM can be produced and delivered to Customers. Use of the CD-ROM The CD-ROM can be used both in PC and Unix WS environments. The CD-ROM starts automatically with autorun and hyperlinks from the opened “Index" document permit to visualize the .pdf handbooks Other hyperlinks permit to get, from the Technical handbooks, the specific .pdf setting documents. In order to open the .pdf documents Adobe Acrobat Reader Version 4.0 (minimum) must have been installed on the platform. The CD-ROM doesn't contain the Adobe Acrobat Reader program. The Customer is in charge of getting and installing it. ReadMe info is present on the CD-ROM to this purpose. Then the Customer is allowed to read the handbooks on the PC/WS screen, using the navigation and zooming tools included in the tool, and to print selected parts of the documentation through a local printer.
  • 19. User Manual Preface 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 17/308 CD-ROM identification Each CD-ROM is identified: 1) by external identifiers, that are printed on the CD-ROM upper surface: – the name of the "product-release(s)" (and "version" if applicable) – a writing indicating the language(s), – the CD-ROM Part Number), – the CD-ROM edition (usually first edition=01) 2) and, internally, by the list of the source handbooks and documents (P/Ns and editions) by whose collection and processing the CD-ROM itself has been created. CD-ROM updating The list of source handbook/document P/Ns-editions indicated in previous para. point 2) , in association with the CD-ROM's own P/N-edition, is also loaded in the Alcatel-Information-System as a structured list. Whenever a new edition of any of such handbooks/documents is released in the Alcatel-Lucent archive system, a check in the Alcatel-Information-System is made to identify the list of CD-ROMs that must be updated to include the new editions of these handbooks/documents. This causes the planning and creation of a new edition of the CD-ROM. Updating of CD-ROMs always follows, with a certain delay, the updating of the single handbooks com- posing the collection.
  • 20. User Manual Preface 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 118/308
  • 21. User Manual Safety, EMC, EMF, ESD Norms and Equipment Label- 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 19/308 1 Safety, EMC, EMF, ESD Norms and Equipment Labelling This chapter describes the equipment labelling and the norms mandatory or suggested that must be con- sidered to avoid injuries on persons and/or damage to the equipment. This chapter is organized as follows: – Declaration of conformity to CE marking and Countries List – Specific label for MPR equipment – Applicable standards and recommendations – Safety Rules – Electromagnetic Compatibility (EMC norms) – Equipment protection against electrostatic discharges – Cautions to avoid equipment damage
  • 22. User Manual Safety, EMC, EMF, ESD Norms and Equipment Label- 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 120/308 1.1 Declaration of conformity to CE marking and Countries List Indication of the countries where the equipment is intended to be used: Austria (AT) - Belgium (BE) - Bulgaria (BG) - Switzerland/Liechtenstein (CH) - Cyprus (CY) - Czech Republic (CZ) - Germany (DE) - Denmark (DK) - Estonia (EE) - Finland (FI) - France (FR) - Greece (GR) - Hungary (HU) – Italy (IT) - Ireland (IE) - Iceland (IS) - Lithuania (LT) – Luxembourg (LU) - Latvia (LV) - Malta (MT) - Netherlands (NL) - Norway (NO) –Poland (PL) – Portugal (PT) - Romania (RO) – Spain (SP) - Sweden (SE) - Slovenia (SI) - Slovak Republic (SK) -United Kingdom (UK) Indication of the intended use of the equipment: Point to Point PDH/Ethernet Transport radio Link
  • 23. User Manual Safety, EMC, EMF, ESD Norms and Equipment Label- 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 21/308 1.2 Specific label for MPR equipment The label is sticked on the MSS-1c and on the MPT-HC/MPT-MC. Field Field Name Note A Alcatel-Lucent Logo B Equipment acronym C Power Supply range See NB 1 for MSS-1c See NB 2 for MPT-HC See NB 3 for MPT-MCD Current range E European Community Logo F Not harmonized frequency logo G WEEE Logo H Electrostatic Device Logo NB 1: – 38.4 V / - 57.6 V; 3.3 A max. NB 2: – 28 V / - 58 V; 1.6 A / 0.8 A NB 3: – 28 V / - 58 V; 1.6 A / 0.8 A 1.3 Applicable standards and recommendations 1999/5/CE of 09 March 1999 Safety: EN 60950, EN 60825-1, EN 60825-2, EN 50385 EMC: EN 301 489-1, EN 301 489-4 Spectrum: EN 302 217-2-2
  • 24. User Manual Safety, EMC, EMF, ESD Norms and Equipment Label- 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 122/308 1.4 Safety Rules 1.4.1 General Rules Before carrying out any installation, turn-on, tests or operation and maintenance operations, read carefully the related sections of this Manual, in particular: – Hardware Installation – Commissioning – Maintenance and Upgrade Observe safety rules – When equipment is operating nobody is allowed to have access inside on the equipment parts which are protected with Cover Plate Shields removable with tools. – In case of absolute need to have access inside, on the equipment parts when it is operating this is allowed exclusively to service personnel, where for Service Personnel or Technical assistance is meant: • "personnel which has adequate Technical Knowledge and experience necessary to be aware of the danger that he might find in carrying out an operation and of the necessary measure- ments to reduce danger to minimum for him and for others". • The Service Personnel can only replace the faulty units with spare parts. • The Service Personnel is not allowed to repair: hence the access to the parts no specified is not permitted. • The keys and/or the tools used to open doors, hinged covers to remove parts which give access to compartments in which are present high dangerous voltages must belong exclusively to the service personnel. – For the eventual cleaning of the external parts of the equipment, absolutely do not use any inflam- mable substance or substances which in some way may alter the markings, inscriptions ect. – It is recommended to use a slightly wet cleaning cloth. The Safety Rules stated in the handbook describe the operations and/or precautions to observe to safe- guard service personnel during the working phases and to guarantee equipment safety, i.e., not exposing persons, animals, things to the risk of being injured/damaged. Whenever the safety protection features have been impaired, REMOVE POWER. To cut off power proceed to switch off the power supply units as well as cut off power station upstream (rack or station distribution frame). The safety rules described in this handbook are distinguished by the following symbol and statement:
  • 25. User Manual Safety, EMC, EMF, ESD Norms and Equipment Label- 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 23/308 1.4.2 Labels Indicating Danger, Forbiddance, Command It is of utmost importance to follow the instructions printed on the labels affixed to the units and assemblies. – dangerous electrical voltages – harmful optical signals – risk of explosion – moving mechanical parts – heat-radiating Mechanical Parts – microwave radiations Pay attention to the information stated in the following, and proceed as instructed. The symbols presented in following paragraphs are all the possible symbols that could be present on Alca- tel-Lucent equipment, but are not all necessarily present on the equipment this handbook refers to. Dangerous Electrical Voltages [1] Labeling The following warning label is affixed next to dangerous voltages (>42.4 Vp; >60 Vdc). If it is a Class 1 equipment connected to mains, then the label associated to it will state that the equip- ment will have to be grounded before connecting it to the power supply voltage, e.g.: [2] Safety instructions DANGER! Possibility of personal injury: Carefully observe the specific procedures for installation / turn-up and commissioning / maintenance of equipment parts where D.C. power is present, described in the relevant installation / turn-up and commissioning / maintenance documents and the following general rules: • Personal injury can be caused by -48VDC. Avoid touching powered terminals with any exposed part of your body. • Short circuiting, low-voltage, low-impedance, DC circuits can cause severe arcing that can result in burns and/or eye damage. Remove rings, watches, and other metal jewelry before working with primary circuits. Exercise caution to avoid shorting power input terminals. Note
  • 26. User Manual Safety, EMC, EMF, ESD Norms and Equipment Label- 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 124/308 Risks of Explosions: labeling and safety instructions This risk is present when batteries are used, and it is signaled by the following label: Therefore, slits or apertures are made to let air circulate freely and allow dangerous gasses to down flow (battery-emitted hydrogen). A 417-IEC-5641 Norm. compliant label is affixed next to it indicating that the openings must not be covered up. Moving Mechanical Parts: labeling and safety instructions The following warning label is affixed next to fans or other moving mechanical parts: Before carrying out any maintenance operation see that all the moving mechanical parts have been stopped. Equipment connection to earth Terminals for equipment connection to earth , to be done according to international safety standards, are pointed out by the suitable symbol: The position of earth connection terminals is specified in the Hardware Installation section.
  • 27. User Manual Safety, EMC, EMF, ESD Norms and Equipment Label- 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 25/308 Heat-radiating Mechanical Parts: labeling and safety instructions The presence of heat-radiating mechanical parts is indicated by the following warning label in compliancy with IEC 417 Norm, Fig.5041: DANGER! Possibility of personal injury: Carefully observe the specific procedures for installation / turn-up and commissioning / maintenance of equipment parts where heat-radiating mechanical parts are present, described in the relevant installation / turn-up and commissioning / maintenance documents and the following general rule: Personal injury can be caused by heat. Avoid touching powered terminals with any exposed part of your body. Optical safety The equipment contains Class 1 laser component according to IEC 60825-1 (par. 5). CLASS 1 LASER PRODUCT The laser source is placed in the optional SFP plug-in, which has to be installed in the MSS-1c. The laser source is placed in the left side of the SFP plug-in. According to the IEC 60825-1 the explanatory label is not sticked on the equipment due to the lack of space. Microwave radiations (EMF norms) Equipment emitting RF power (Reminder from site preparation procedure): The site must be compliant with ICNIRP guidelines or local regulation if more restrictive. The following rules should be strictly applied by Customer: – Non authorized persons should not enter the compliance boundaries, if any, for the general public. – Compliance RF boundaries, if any, related to Electro Magnetic Field exposure must be marked. – Workers should be allowed to switch-off the power if they have to operate inside compliance bound- aries. – Assure good cable connection. – Install the antenna as high as possible from floor or area with public access ( if possible the cylinder delimitating the compliance boundaries, if any, or the cylinder corresponding to the transmission area directly in front of antenna with the same diameter as the antenna, more than 2 meters high).
  • 28. User Manual Safety, EMC, EMF, ESD Norms and Equipment Label- 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 126/308 – Install the antenna as far as possible from other existing equipment emitting RF power. Anyway remind that someone standing in front of the 9500 MPR antenna may cause traffic shutdown. Place the relevant stickers: EMF emission warning sign On the site when applicable (when people can cross the compliance boundaries and/or the transmission area of the antenna, i.e. roof top installation) – Warning label "Do not stand on the antenna axis" On the mast (front side) – EMF emission warning sign (Yellow and black) to be placed at bottom of antenna, visible by some- one moving in front of the antenna (roof top installation) On the antenna (rear side) – EMF emission warning sign, placed on the antenna. 1.5 Electromagnetic Compatibility (EMC norms) The equipment's EMC norms depend on the type of installation being carried out (cable termination, grounding etc.,) and on the operating conditions (equipment, setting options of the electrical/electronic units, presence of dummy covers, etc.). Before carrying out any installation, turn-on, tests & operation and maintenance operations, read carefully the related sections of this Manual, in particular: – Hardware Installation – Maintenance and Upgrade The norms set down to guarantee EMC compatibility, are distinguished inside this Manual by the symbol and term: EMC Norms [1] EMC General Norms - Installation • All connections (towards the external source of the equipment) made with shielded cables use only cables and connectors suggested in this Manual or in the relevant Plant Documentation, or those specified in the Customer's "Installation Norms" (or similar documents) • Shielded cables must be suitably terminated • Install filters outside the equipment as required
  • 29. User Manual Safety, EMC, EMF, ESD Norms and Equipment Label- 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 27/308 • Ground connect the equipment utilizing a conductor with proper diameter and impedance • Mount shields (if utilized), previously positioned during the installation phase, but not before having cleaned and degrease it • Before inserting the shielded unit proceed to clean and degrease all peripheral surfaces (con- tact springs and connection points, etc.) • Screw fasten the units to the subrack • To correctly install EMC compatible equipment follow the instructions given [2] EMC General Norms - Turn-on, Tests & Operation • Preset the electrical units as required to guarantee EMC compatibility • Check that the equipment is operating with all the shields properly positioned (dummy covers, ESD connector protections, etc.) • To properly use EMC compatible equipment observe the information given [3] EMC General Norms - Maintenance • Before inserting the shielded unit, which will replace the faulty or modified unit, proceed to clean and degrease all peripheral surfaces (contact springs and connection points, etc.) • Clean the dummy covers of the spare units as well • Screw fasten the units to the subrack. 1.6 Equipment protection against electrostatic discharges Before removing the ESD protections from the monitors, connectors etc., observe the precautionary mea- sures stated. Make sure that the ESD protections have been replaced and after having terminated the maintenance and monitoring operations. Most electronic devices are sensitive to electrostatic discharges, to this concern the following warning labels have been affixed: Observe the precautionary measures stated when having to touch the electronic parts during the instal- lation/maintenance phases. Workers are supplied with anti static protection devices consisting of: – an elasticized band worn around the wrist – a coiled cord connected to the elasticized band and to the stud on the subrack
  • 30. User Manual Safety, EMC, EMF, ESD Norms and Equipment Label- 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 128/308 1.7 Cautions to avoid equipment damage a. Anti static protection device kit Whenever is necessary to handle spare parts and cards out of their own box, this kit (Illustration below) must be always warn and its termination must be connected to a grounded structure, to avoid the possible damage of the electronic devices for electrostatic discharges. Anti static protection device kit b. Screw fixing In normal operation conditions, all screws (for unit box closing, cable fixing, etc.) must be always tightened to avoid item detachment and to ensure the equipment EMI-EMC performance. The screw tightening torque must be: 2.8 kg x cm (0.28 Newton x m) ±10 % 2.4317 in lb (0.2026 ft lb) ±10 % Exceeding this value may result in screw breaking. c. MSS-1c-ODU cable disconnection / connection Before to disconnect or connect the MSS-1c-ODU cable (at MSS-1c or ODU side) switch off the cor- responding MSS-1c Unit.
  • 31. User Manual Product information and planning 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 29/308 2 Product information and planning – 9500 Family overview (par. 2.1 on page 31) • 9500 MPR System Family (par. 2.1.1 on page 35) • Family elements described in this User Manual (par. 2.1.2 on page 36) • MSS-1c (par. 2.1.3 on page 36) • MPT-HC (par. 2.1.4 on page 37) • MPT-MC (par. 2.1.5 on page 37) • MSS-1c to MPT-HC interconnection (par. 2.1.6 on page 38) • MSS-1c to MPT-MC interconnection (par. 2.1.7 on page 40) • Antennas (par. 2.1.8 on page 40) – Radio capacity, channelling and modulation (MPT-HC/MPT-MC) (par. 2.2 on page 41) – Standard Features (par. 2.3 on page 44) – Radio Configurations (par. 2.4 on page 44) – Typical System Configurations (par. 2.5 on page 45) – Environmental and Electrical Characteristics (par. 2.6 on page 46) • General characteristics (MSS-1c) (par. 2.6.1 on page 46) • General characteristics (MPT-HC/MPT-MC) (par. 2.6.2 on page 47) • MPT-HC characteristics (par. 2.6.4 on page 49) – 6 to 13 GHz (par. 2.6.4.1 on page 49) – 15 to 38 GHz (par. 2.6.4.2 on page 49) • MPT-MC characteristics (par. 2.6.3 on page 48) – 6 to 13 GHz (par. 2.6.3.1 on page 48) – 15 to 38 GHz (par. 2.6.3.2 on page 48) • Radio performances (par. 2.6.5 on page 49) • General characteristics (MSS-1c) (par. 2.6.1 on page 46) • General characteristics (Power Extractor) (par. 2.6.6 on page 50) – Parts Lists (par. 2.7 on page 51) • MSS-1c (par. 2.7.1 on page 51) • MPT-HC optical interface option (par. 2.7.2 on page 51) • MPT-HC with internal diplexer (par. 2.7.3 on page 52) • MPT-MC with internal diplexer (par. 2.7.4 on page 54) • MPT-HC/MPT-MC with external diplexer (7/8 GHz) (par. 2.7.5 on page 56) – Functional description (par. 2.8 on page 59) • MSS-1c (Indoor Unit) (par. 2.8.1 on page 59) – Power supply (par. 2.8.1.2 on page 61) – Ethernet switch (par. 2.8.1.3 on page 61) – E1 Interface (par. 2.8.1.4 on page 61) – MPT Interface (par. 2.8.1.5 on page 62) • Fan unit (par. 2.8.2 on page 63) • MPT-HC (par. 2.8.3 on page 64) – MPT-HC block diagram (par. 2.8.3.1 on page 66)
  • 32. User Manual Product information and planning 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 130/308 – RSSI Monitoring Point (par. 2.8.3.2 on page 72) – Waveguide Flange Data (par. 2.8.3.3 on page 72) • Power Extractor (par. 2.8.4 on page 73) • MPT-MC (par. 2.8.5 on page 74) • Radio Transmission Features with MPT-HC/MPT-MC (par. 2.8.6 on page 75) – Frequency Agility (par. 2.8.6.1 on page 75) – Automatic Transmit Power Control (ATPC) (par. 2.8.6.2 on page 75) – Transmitted power control: RTPC function (par. 2.8.6.3 on page 76) – Power Monitoring (par. 2.8.6.4 on page 76) – Adaptive Equalization (par. 2.8.6.5 on page 76) – Link identifier (par. 2.8.6.6 on page 76) – Loopbacks (par. 2.8.6.7 on page 76) – Loopback activation (par. 2.8.6.8 on page 77) – Loopback life time (par. 2.8.6.9 on page 78) • TMN communication channels (par. 2.8.7 on page 78) • Traffic profiles (par. 2.8.8 on page 79) – TDM2TDM (par. 2.8.8.1 on page 81) – TDM2Eth (par. 2.8.8.2 on page 82) – ETH2ETH (par. 2.8.8.3 on page 83) • Ethernet Traffic Management (par. 2.8.9 on page 84) – Bridge type change (par. 2.8.9.1 on page 84) – Reserved Multicast Addresses (par. 2.8.9.2 on page 84) • Quality Of Services (QoS) (par. 2.8.10 on page 85) – QoS in the MSS-1c (par. 2.8.10.1 on page 85) – QoS in the MPT (par. 2.8.10.2 on page 87) • Cross-connections (par. 2.8.11 on page 89) – E1 Cross-connection (par. 2.8.11.1 on page 89) – Ethernet flows (par. 2.8.11.2 on page 90) • Synchronization (par. 2.8.12 on page 91) – Synchronization overview (par. 2.8.12.1 on page 91) – Synchronization interface (par. 2.8.12.2 on page 93)
  • 33. User Manual Product information and planning 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 31/308 2.1 9500 Family overview 9500MPR introduces new elements to the microwave packet family. The most compact IDU solutions (MSS-1c) for E1 and Ethernet hybrid connectivity as well as with a zero footprint solution (no IDU) addressing full out-door applications. The new set of multipurpose ODUs, the MPT addressing any appli- cation in the microwave domain. Stand alone as well as coupled in split mount solutions applications depending on the network requirement and layout. The MPT is available in a variety of flavors to address in the most cost effective the different part of the network, this also include millimeter wavelength. The 9500 Microwave Packet Radio (MPR) is a microwave digital radio family that supports both PDH and packet data (Ethernet) for migrating from TDM to IP. The 9500 MPR provides a generic, modular IP platform for multiple network applications (including 2G/3G/HSDPA/WiMAX backhauling to Metro Ethernet areas) to accommodate broadband services. The 9500 MPR radio family supports low, medium, and high capacity applications using European data rates, frequencies, channel plans, and tributary interfaces: – TDM/PDH Data Rates: E1 – ATM Data Rates: E1 – Ethernet Data Speed: 10, 100, 1000 Mb/s – RF Frequency Range: 6 to 38 GHz Three types of Indoor Units are available: 1) MSS-8, a 2U shelf, connected to an outdoor RF unit (split mount system). Supported ODUs: – ODU300 – MPT-HC – MPT-MC
  • 34. User Manual Product information and planning 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 132/308 2) MSS-4, one 1U shelf, connected to an outdoor RF unit (split mount system). Supported ODUs: – ODU300 – MPT-HC – MPT-MC 3) MSS-1c. Compact IDU that complements the existing portfolio addressing the last mile, the far end application in nodal solution and cost optimized point-to-point applications. Its small size of 1U height and half rack width drastically reduces the space consumption in busy sites. Supported ODUs: – MPT-HC – MPT-MC MPT is a new multipurpose ODU to address any microwave application, extremely compact in size pro- viding: – MPT-MC: 155 Mbps max. – MPT-HC: 340 Mbps max. MPT-xx can be deployed in stand-alone configuration (9500 MPR-e) or it can be deployed in split mount solution connected to any MSS-x IDU. – Up to 12 MPT connected to an MSS-8; highest density ever – Up to 6 MPT connected to an MSS-4; highest density ever – Up to 2 MPT HC/MC connected to MSS-1c (up to 1 limited in the current version) 9500 MPR-e is the stand alone, full outdoor application of the MPT xx to address full Ethernet site back- hauling (fix or mobile alike) and to address converged MPLS metro networks reducing the number of deployed equipment. The 9500 MPR innovative solutions mainly are: [1] Multiservice aggregation layer: the capacity to use Ethernet as a common transmission layer to transport any kind of traffic, independently by the type of interface. Ethernet becomes the conver- gence layer. [2] Service awareness: traffic handling and quality management, queuing traffic according to the type of service assigned, independently by the type of interface [3] Packet node: no service aggregation limits with all traffic aggregated in packets, in term of: capacity, type of service requirements and type of interface [4] Service-driven adaptive modulation: fully exploit the air bandwidth in its entirety by changing mod- ulation scheme according to the propagation availability and allocate transport capacity, discrimi- nating traffic by different services, only possible in a packet-based environment.
  • 35. User Manual Product information and planning 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 33/308 [1] Multiservice aggregation layer Figure 1. Multiservice Aggregation Layer 9500 MPR aggregates and carries over a COMMON PACKET LAYER: TDM 2G, 3G and IP/Ethernet. This allows sharing of common packet transmission infrastructures, regardless of the nature of carried traffic. Due to the nature of Ethernet, each service can be discriminated based on several parameters like quality of service. Mapping different access technologies over Ethernet is achieved by standardized protocols like circuit emulation and pseudo-wire. [2] Service awareness Figure 2. Service Awareness Service awareness means the ability to discriminate the different traffic types carried over the converged Ethernet stream. The traffic flow can be composed by E1 and/or IP/Eth, coming from different sources, and therefore having different requirements. Service awareness is what allows identifying the traffic types, and in case of the non real time variable bit rate one, optimize the band with overbooking of the radio scarce resource.
  • 36. User Manual Product information and planning 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 134/308 [3] Packet node Figure 3. Packet Node 9500 MPR offers a SINGLE PACKET MATRIX able to switch, aggregate and handle any of the possible incoming traffic types with virtually no capacity limits (up to 10 GBps). [4] Service-driven adaptive modulation Figure 4. Service-driven Packet Adaptive Modulation Traffic with high priority will always have bandwidth available, like voice (deterministic approach). Broadband traffic is discriminated by QoS dynamically, with modulation scheme changes driven by propagation conditions.
  • 37. User Manual Product information and planning 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 35/308 2.1.1 9500 MPR System Family Figure 5. 9500 MPR System Family 9500 MPR in the stand alone (zero-footprint) architecture is built by only one unit for Ethernet applications: – Outdoor Unit. – Outdoor Unit is connected to the MPLS metro networks equipment with one coaxial cable for the power supply and one Ethernet optical or electrical cable (with MPT). 9500 MPR in the split mount architecture is built by two separate units: – MSS (Microwave Service Switch): indoor unit for split mount and stand alone configurations (Ether- net uplink) – Outdoor Unit.
  • 38. User Manual Product information and planning 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 136/308 2.1.2 Family elements described in this User Manual In this User Manual the access solution with the MSS-1c and MPT-HC/MPT-MC is described: The implemented radio configuration is 1+0. The MSS-1c can collect up to 10 TDM flows and Ethernet flows. The MSS-1c interfaces the Outdoor Unit (MPT-HC or MPT-MC) thanks to its Ethernet interface. MPT-HC or MPT-MC is in a charge of transporting the flows in an efficient way (bandwidth optimization, Quality of service, respect to TDM contraints ....). 2.1.3 MSS-1c The MSS-1c provides user port interface, cross-connection and switching management. The cross-connection matrix implements all the cross-connections between the User ports (4 Ethernet ports and 10 E1 streams) and the Radio port. The matrix is a standard Ethernet switch, based on VLAN, assigned by the MCT. The 10xE1 enter the LIU and then the IWF, which manages the encapsulation/reconstruction of PDH data to/from standard Ethernet packets and sends/receives standard Ethernet packets to/from the Ethernet switch. The Radio Interface interfaces the MPT-HC or the MPT-MC. The radio interface is a standard GbEth inter- face electrical for MPT-MC, electrical or optical for MPT-HC. It sends/receives standard Ethernet packets to/from the Ethernet switch. In case of electrical radio interface, on the same cable is also sent the power supply for the MPT by using the Power Feed over Ethernet (PFoE) function. To connect MSS-1c and MPT-HC with only one electrical cable, the Power Extractor must be installed close to the MPT-HC. In this case the interconnection between the MSS-1c and the MPT-HC is made with a single electrical Ethernet cable by using the Power Feed over Ethernet (Ethernet traffic and Power Sup- ply on the same cable). The Power Extractor then separates the Power Supply from the Ethernet traffic, which are separately sent to the MPT-HC. The MPT-HC can be connected also by using an optical cable for the Ethernet traffic and a coaxial cable for the power supply. Note
  • 39. User Manual Product information and planning 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 37/308 2.1.4 MPT-HC MPT-HC is a Microwave Equipment capable of transporting the Ethernet traffic over an RF radio channel. MPT-HC is a microprocessor-controlled equipment that interfaces the MSS-1c with the antenna. The input interface can be a standard electrical Giga Ethernet interface, connected to the Power Extractor as shown in Figure 8. or a standard optical Giga Ethernet interface, connected to the MSS-1c as shown in Figure 9.. The Ethernet traffic is transmitted over the radio channel according to the configured QoS and to the scheduler algorithms. Transmitter circuits in the MPT-HC consist of Ethernet input interface, modulator, local oscillator, upcon- verter/mixer, power amplifier, and diplexer. Receiver circuits consist of diplexer, low-noise amplifier, local oscillator, downconverter/mixer, automatic gain control, demodulator and Ethernet output interface. The microprocessor manages the frequency, transmit power alarming, and performance monitoring. The power is provided from the Power Extractor to the MPT-HC DC-DC converter through a dedicated power supply cable. The MPT-HC is frequency dependent. Figure 6. MPT-HC 2.1.5 MPT-MC MPT-MC is similar to MPT-HC from architecture standpoint. MPT-MC has limited capacity vs MPT-HC and is natively Ethernet powered (no Power Extractor is required). Figure 7. MPT-MC
  • 40. User Manual Product information and planning 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 138/308 2.1.6 MSS-1c to MPT-HC interconnection 2.1.6.1 Electrical cable One electrical Ethernet cable connects the MSS-1c to its MPT-HC. The max cable length is 100 m. The Ethernet electrical cable is provided with connectors to be mounted on site with the specific RJ45 tool (1AD160490001). Figure 8. MPT-HC connection (electrical cable) With the MPT-HC the Power Extractor must be installed close to the MPT-HC. In this case the intercon- nection between the MSS-1c and the MPT-HC is made with a single electrical Ethernet cable by using the Power Feed over Ethernet (Ethernet traffic and Power Supply on the same cable). The Power Extrac- tor then separates the Power Supply from the Ethernet traffic, which are separately send to the MPT-HC. Note
  • 41. User Manual Product information and planning 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 39/308 2.1.6.2 Optical cable One optical Ethernet cable connects the MSS-1c to its MPT-HC. The max cable length is 350 m. A coaxial cable connects the MPT-HC to the MSS-1c (Figure 9) or to Station battery (Figure 10). Figure 9. MPT-HC connection (optical cable + power supply cable to MSS-1c) Figure 10. MPT-HC connection (optical cable + power supply cable to Station battery)
  • 42. User Manual Product information and planning 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 140/308 2.1.7 MSS-1c to MPT-MC interconnection One electrical Ethernet cable connects the MSS-1c to its MPT-MC. The max cable length is 100 m. The Ethernet electrical cable is provided with connectors to be mounted on site with the specific RJ45 tool (1AD160490001). Figure 11. MPT-MC connection 2.1.8 Antennas Antennas for direct mounting an MPT are available in diameters from 0.3 m to 1.8 m, depending on the frequency band. A polarization rotator is included within the antenna collar, and direct-mounting equal or unequal loss couplers are available for single antenna protected operation. Antenna mounts are designed for use on industry-standard 114 mm OD pipe-mounts. An MPT can also be used with standard antennas via a remote-mount kit and flexible waveguide.
  • 43. User Manual Product information and planning 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 41/308 2.2 Radio capacity, channelling and modulation (MPT-HC/MPT-MC) Table 1. Radio capacity, channelling scheme and modulation (Static Modulation) Channel Spacing (MHz) FCM Mode ETSI Class # E1 (TDM2TDM) Typical Ethernet Throughput (1518 bytes) 3.5 QPSK 2 2 4,2 Mbit/s 8PSK 2 3 6,8 Mbit/s 16 QAM 4 4 8,5 Mbit/s 32 QAM 4 5 10,8 Mbit/s 64 QAM 5 6 13,5 Mbit/s 7 QPSK 2 4 8,8 Mbit/s 8PSK 2 6 13,5 Mbit/s 16 QAM 4 9 19,4 Mbit/s 32 QAM 4 11 24,2 Mbit/s 64 QAM 5 13 29,6 Mbit/s 128 QAM 5 16 35,4 Mbit/s 256 QAM (NB3) 6 19 40,6 Mbit/s 14 QPSK 2 9 19,9 Mbit/s 8PSK 2 14 30,0 Mbit/s 16 QAM 4 19 40,7 Mbit/s 32 QAM 4 23 50,3 Mbit/s 64 QAM 5 29 62,0 Mbit/s 128 QAM 5 34 73,5 Mbit/s 256 QAM (NB3) 6 41 86,7 Mbit/s 28 QPSK 2 19 41,1 Mbit/s QPSK 2 (NB1) 20 42,8 Mbit/s 8PSK 2 29 61,9 Mbit/s 16 QAM 4 39 83,5 Mbit/s 16 QAM 4 (NB1) 41 87,1 Mbit/s 32 QAM 4 50 106,9 Mbit/s 64 QAM 5 60 128,3 Mbit/s 128 QAM 5 71 151,8 Mbit/s 256 QAM (NB3) 6 85 180,0 Mbit/s 40 (NB2) 64 QAM 5 88 186,0 Mbit/s 128 QAM 5 104 220,0 Mbit/s
  • 44. User Manual Product information and planning 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 142/308 N.B.1: New ETSI mask. N.B.2: MPT-MC does not support this Channel Spacing. N.B.3: MPT-MC does not support this FCM mode. 56 (NB2) 16 QAM 4 75 159,1 Mbit/s 16 QAM 4 (NB1) 76 161,0 Mbit/s 32 QAM 4 92 195,4 Mbit/s 64 QAM 5 119 252,0 Mbit/s 128 QAM 5 141 298,0 Mbit/s 256 QAM 6 160 339,1 Mbit/s
  • 45. User Manual Product information and planning 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 43/308 Table 2. Radio capacity, channelling scheme and modulation (Adaptive Modulation) Channel Spacing (MHz) ACM Mode Reference ETSI Class Modulation range Typical Ethernet Throughput (1518 bytes) 3.5 QPSK 2 QPSK to 64 QAM 4,3 Mbit/s 16 QAM 4 16 QAM to 64 QAM 8,5 Mbit/s 7 QPSK 2 QPSK to 256 QAM 8,8 Mbit/s 16 QAM 4 16 QAM to 256 QAM 19,4 Mbit/s 32 QAM 4 32 QAM to 256 QAM 24,2 Mbit/s 64 QAM 5 64 QAM to 256 QAM 29,6 Mbit/s 14 QPSK 2 QPSK to 256 QAM 19,9 Mbit/s 16 QAM 4 16 QAM to 256 QAM 40,7 Mbit/s 32 QAM 4 32 QAM to 256 QAM 50,3 Mbit/s 64 QAM 5 64 QAM to 256 QAM 62,0 Mbit/s 28 QPSK 2 QPSK to 256 QAM 41,0 Mbit/s QPSK 2U QPSK to 256 QAM 42,8 Mbit/s 16 QAM 4 16 QAM to 256 QAM 83,5 Mbit/s 16 QAM 4U 16 QAM to 256 QAM 87,1 Mbit/s 32 QAM 4 32 QAM to 256 QAM 106,9 Mbit/s 64 QAM 5 64 QAM to 256 QAM 128,3 Mbit/s 40 (NB1) 64 QAM 5 64 QAM to 128 QAM 186,0 Mbit/s 56 (NB1) 16 QAM 4 16 QAM to 256 QAM 159,0 Mbit/s 16 QAM 4U 16 QAM to 256 QAM 161,0 Mbit/s 32 QAM 4 32 QAM to 256 QAM 195,4 Mbit/s 64 QAM 5 64 QAM to 256 QAM 251,9 Mbit/s N.B.1: MPT-MC does not support this Channel Spacing.
  • 46. User Manual Product information and planning 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 144/308 2.3 Standard Features More radio and site scalability and flexibility for installation teams: – Limited need for factory presetting channel frequency or bandwidth – Supports cellular mobile networks, and microcellular network back and common carrier, private carrier and data networks, and utility haul applications. – 2G, 2.5G, and 3G network compatible – Outdoor Unit capacity and modulation independent – Outdoor Unit can support either split-mount and full-outdoor architecture with the same hardware – Flexible aggregate capacity sharing between E1 and Ethernet – Adaptive packet transport that improves performance for priority services – Output power agility – ATPC – Adaptive Modulation – Packet-based internal cross-connect – TDM MEF8 encapsulation – Electrical GE interfaces – Software-based configuration – High Switching Capacity 2.4 Radio Configurations In the current release the following radio configuration is available: – 1+0 in split-mount
  • 47. User Manual Product information and planning 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 45/308 2.5 Typical System Configurations – TDM Over Ethernet Packet Node - Mapping of 10 E1 TDM on Ethernet (Figure 12.) N.B. In this case a connected MPT is needed in order to configure the cross-connections. – TDM and Ethernet Terminal Packet Transport 10 E1 TDM and 1 Radio Direction (Figure 13.) MSS-1c Packet SW 10E1TDM Interface Built-in Ethernet Figure 12. TDM Over Ethernet Packet Node - Mapping of 10 E1 TDM on Ethernet MSS-1c Packet SW 10E1TDM Interface Built-in Ethernet Radio Interface MPT Figure 13. TDM and Ethernet Terminal Packet Transport 10 E1 TDM and 1 Radio Direction
  • 48. User Manual Product information and planning 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 146/308 2.6 Environmental and Electrical Characteristics – General characteristics (MSS-1c) (par. 2.6.1) – General characteristics (MPT-HC/MPT-MC) (par. 2.6.2) – MPT-MC characteristics (par. 2.6.3) – MPT-HC characteristics (par. 2.6.4) – Radio performances (par. 2.6.5) – General characteristics (Power Extractor) (par. 2.6.6) 2.6.1 General characteristics (MSS-1c) Power Injector Input Voltage range -38.4 to -57.6 Vdc Standards Compliance (Power Injector) EMC EN 301 489-1, EN 301 489-4, EN 55022 Class B Stationary use ETS 300 019 1-3, Class 3.2 Storage ETS 300 019 2-1, Class 1.2 Transportation ETS 300 019 2-2, Class 2.3 Safety EN 60950 Environmental Operating Temperature -20° to +50° C (without FAN unit) -20° to +65° C (with FAN unit) Cold start-up -40° C Humidity 0 to 95%, non condensing Management Protocol SNMP Interface, electrical Ethernet 10/100/1000 Base-T Interface, electrical physical RJ-45 Routing Protocols supported Static routing Network Management Alcatel-Lucent 1350 OMS Alcatel-Lucent 1352 Compact Alcatel-Lucent 5620 SAM
  • 49. User Manual Product information and planning 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 47/308 2.6.2 General characteristics (MPT-HC/MPT-MC) General with MPT-HC Operating Frequency Range 6 - 38 GHz Max. Ethernet throughput 340 Mbps Bandwidth up to 56 MHz Modulation Options in FCM QPSK, 8PSK, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM Adaptive Modulation QPSK, 8PSK, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM General with MPT-MC Operating Frequency Range 6 - 38 GHz Max. Ethernet throughput 155 Mbps Bandwidth up to 28 MHz Modulation Options in FCM QPSK, 8PSK, 16 QAM, 32 QAM, 64 QAM, 128 QAM Adaptive Modulation QPSK, 8PSK, 16 QAM, 32 QAM, 64 QAM, 128 QAM Radio Path Protection Options Non Protected, 1+0 Standards Compliance (MPT-HC/MPT-MC) EMC EN 301 489-1, EN 301 489-4, EN 55022 Class B Stationary use ETS 300 019, Class 4.1 Storage ETS 300 019, Class 1.2 Transportation ETS 300 019, Class 2.3 Safety IEC 60950-1/EN 60950-1 Radio Frequency EN 302 217 Classes 2, 4 & E5 Water Ingress IEC 60529 (IPX6) Environmental Operating Temperature (Guaranteed) -33° to +55° C Start up temperature from low temperature -40° C Humidity (Guaranteed) 0 to 100%
  • 50. User Manual Product information and planning 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 148/308 2.6.3 MPT-MC characteristics 2.6.3.1 6 to 13 GHz System Frequency Range, GHz 5.925 - 6.425 6.425 - 7.11 7.125 - 7.9 7.725 - 8.5 10.7 - 11.7 12.75 - 13.25 T-R Spacings supported MHz 252.04 340 154-161- 168-196 119-126- 294-305- 311-32 490-500- 530 266 Antenna Interface Waveguide Type WR137 WR137 WR112 WR113 WR75 WR62 Typical power consumption 38 W Guaranteed power consumption 2.6.3.2 15 to 38 GHz System Frequency Range, GHz 14.4 - 15.35 17.7 - 19.7 21.2 - 23.632 24.52 - 26.483 37.0 - 39.46 T-R Spacings supported MHz 420- 490 1008- 1010- 1560 1008- 1050- 1200- 1232 1008 1260 Antenna Interface Waveguide Type WR62 WR42 WR42 WR42 WR28 Typical power consumption 38 W Guaranteed power consumption L6 GHz U6 GHz 7 GHz 8 GHz 11 GHz 13 GHz 40 W 15 GHz 18 GHz 23 GHz 26 GHz 38 GHz 40 W
  • 51. User Manual Product information and planning 9500 MPR-E Rel. 2.2.0 3DB 18782 AAAA Issue 1 49/308 2.6.4 MPT-HC characteristics 2.6.4.1 6 to 13 GHz System Frequency Range, GHz 5.925 - 6.425 6.425 - 7.11 7.125 - 7.9 7.725 - 8.5 10.7 - 11.7 12.75 - 13.25 T-R Spacings supported MHz 252.04 340 154, 161, 168, 196, 245 119; 126; 151.614; 208; 213,5; 266; 294; 305; 311.32 490-530 266 Antenna Interface Waveguide Type WR137 WR137 WR112 WR113 WR75 WR62 Typical power consumption 38 W Guaranteed power consumption 2.6.4.2 15 to 38 GHz System Frequency Range, GHz 14.4 - 15.35 17.7 - 19.7 21.2 - 23.632 24.52 - 26.483 37.0 - 39.46 T-R Spacings supported MHz 308-315- 322, 420, 490, 644, 728 1008- 1010, 1560, 340 1008- 1050- 1200- 1232 1008 1260 Antenna Interface Waveguide Type WR62 WR42 WR42 WR42 WR28 Typical power consumption 38 W Guaranteed power consumption 2.6.5 Radio performances The radio performances are provided in the “Technical Description” document. L6 GHz U6 GHz 7 GHz 8 GHz 11 GHz 13 GHz 42 W 15 GHz 18 GHz 23 GHz 26 GHz 38 GHz 42 W