1. “Bringing the Future to Light”
Presented By:
Green-Energy-Products. Com, LLC
Eco-friendly, energy efficient lighting solutions… think green
Toll Free: 800-639.8796
www.green-energy-products.com
2. Agenda
1. Company Overview
2. Product Overview. What is “RealTime Lighting”?
3. Typical Lamp life and Maintenance
4. Benefits of RealTime Lighting
5. Popular Applications
6. Case studies
3. Product Overview
What is “RealTime Lighting”?
Essentially a fluorescent lamp without electrodes or
filaments.
R ings w ith m agnetic coils create an electro
m agnetic field using a high frequency
generated by the electronic ballast.
Electrons discharged by the magnetic coils collide with
mercury atoms inside the glass tube and become
activated.
These electrons give off energy in the form of
invisible UV light.
The conversion to visible light occurs when it passes
through a phosphor coating on the inside surface of
the tube.
The lamp therefore relies on the fundamental principles of gas discharge and
electromagnetic “induction” to produce light.
As a result the lam p offers an unm atched life span . They can last longer
than 100 incandescent bulbs, 5 HID, or 5 typical fluorescent lamp changes.
Eco-friendly, energy efficient, lighting solutions…think green
4. S/P Ratio
Definition: The S/P ratio determines the apparent visual brightness of a light source
and determines how much light a lamp produces which is useful to the human eye (i.e.
Visually Effective Lumens/Lux).
Measurement: The S/P ratio of a light source is determined by measuring
the output in Lumens or Lux using a light meter or spectrometer calibrated
first to the Photopic vision sensitivity curve, and then measuring the same light
with instruments calibrated to the Scotopic vision sensitivity curve. The
resulting numbers form a ratio that is expressed as a single number.
S/P RATIO
Sun + Sky: 2.47
6500k RealTime Lamp: 2.25
5000k RealTime Lamp: 1.96
4100k RealTime Lamp: 1.62
Metal Halide (Na/Sc): 1.49
High Pressure Sodium(50w): 1.14
Incandescent (2850k): 1.41
Warm White Fluorescent: 1.00
(Credit: Francis Rubenstein of Berkley Labs)
5. S/P Ratio in Action
Typical Lamp Application (1 to 1 comparison):
120 W Low pressure Sodium lamp [SOX 120] X 140 Lumens/W8 =
16,800 Lumens X 0.35(S/P Ratio) = 5,880 lumens of light
useful to human vision.
120 W RealTime lamp X 80 Lumens/W = 10,200 Lumens X
1.96(S/P Ratio) =18,816 lumens of light useful to human vision
Typical Lamp Application (50% energy reduction):
400W Metal Halide lamp [M 400] X 54.6 Lumens/W8 = 21,840 Lumens X
1.497 = 32,541 useful lumens
200W RealTime lamp X 81 Lumens/W = 16,200 Lumens X 1.96 = 31,752
useful lumens
NOTE: The calculations above do not take into account actual electrical energy consumption which would
include losses in the ballasts and would make the RealTime induction lamp even more efficient.
Eco-friendly, energy efficient, lighting solutions…think green
6. CRI (Color Rendering Index)
CRI:
The best possible rendering
of colors is specified by a CRI
of 100.
RealTime Induction lamps
come in a wide range of color
temperatures, between
3500K – 6500K, with 90+
CRI.
This high CRI makes objects
look bright, clear and natural
under the RealTime induction
lamp
Eco-friendly, energy efficient, lighting solutions…think green
7. A Picture is Worth a Thousand Words
250 Watt High Pressure Sodium 120 Watt RealTime Lamp
Eco-friendly, energy efficient, lighting solutions…think green
8. Typical Lamp Life
TYPICAL LAMP LIFE
Incandescent Bulbs: 750-1,000 hours, 0.22 Years
Halogen Bulbs: 2,000-3,000 hours, 0.68 Years
Metal Halide: 7,500-10,000 hours, 2.2 Years
Fluorescent: 15,000-20,000 hours, 4.6 Years
Mercury Vapor: 16,000-24,000 hours, 5.4 Years
High Pressure Sodium: 15,000-24,000 hours, 5.4. Years
R ealTim e Lighting: 80,000-100,000 hours, 22.8 Years
**based on 12 hours per day 7 days per week**
Eco-friendly, energy efficient, lighting solutions…think green
10. Features of RealTime’s Lamp & Ballast
• 100,000 hour life time
• 5 year warranty
• No electrodes & no filaments
• Wide range of colour temperatures (3500K – 6500K)
• Wide range of wattages
• Instant on and Instant re-strike capabilities
• Wide operating temperatures (-40F to +122F)
• 90+ CRI
• .92 power factor
• 100% flicker free / no hum
• 98% efficient – 2% ballast overhead loss
• 80 – 92 lumens per watt
• Lumen maintenance of 80% at 90% of rated life span
• 120 volt – 277volt – 347 volt ballasts
Eco-friendly, energy efficient, lighting solutions…think green
11. Eco-Friendly
‘RealTime Lighting’
Positive Environmental Impact:
Our Lamps offer a LEED qualifying “Green” lighting product that eliminates toxic
waste disposal costs with 100% recyclable mercury.
Aids the environment with a product that promotes a reduction in overall
greenhouse gas emissions. Less demand for power on local utilities reduces
electrical power generation
Dramatically reduces the contribution of hazardous waste to landfill sites by the
elimination of spent lamps and ballasts
Eliminate the high levels of mercury currently being added to the environment by
disposed lamps
RealTime lamps contain solid amalgam mercury which is 100% recyclable. This
makes the RealTime induction lamp a completely ‘green lighting’ product
NOTE:
Lamps such as Metal Halide, Fluorescent & High Pressure Sodium all contain substances (i.e. mercury) that
are dam aging to the environment
12. Benefits of RealTime Induction Lighting
Energy, Maintenance & Productivity Savings:
Cost Savings: Immediately reduce electric consumption (typical electric savings
range between 40-70%)
Maintenance Savings: Practically maintenance free. 100,000 hour/
5-year warranty on bulb and ballast eliminates the cost of constant maintenance
and re-lamping
HVAC Savings: Ballasts are 98% efficient – no heat generated. HVAC cost
reduction.
Increased Safety and Security – instant on and re-strike – no flicker-no hum
Increases worker productivity with ‘spectrally enhanced’/full spectrum lighting
Eco-friendly, energy efficient, lighting solutions…think green
13. Popular “Green” Lighting from
Green-Energy-Products.Com, LLC
Flood Light Garage Lighting Wallpacks Roadway Lighting Surface Mount
(Billboards/Buildings) (Parking Garages, (outside of buildings) (Schools/Parking Garages…)
Train Stations…)
Sealed Industrial Shoe Box Lighting
(Tunnels/Bridges/Highways) Office Lighting (Parking Lots/Walkways…) Self Ballasted (screw in bulb)
High Bay Lighting Earth embedded Decorative (Parks, Plazas, Down Lighting
(landscape) shopping malls)
14. Retrofit
RealTime Electronic Ballast RealTime Lamp
Many customers choose to keep their existing fixtures by
“retrofitting” the fixture with the RealTime Lamp
& Ballast
15. CASE STUDIES
Town on Long Island, N.Y. Goes Green
…with “induction lighting”
Town Expects to Save Nearly $1 million in 2008
As part of a 12-point 2008 Clean Energy Action Plan:
- phasing-in induction lighting in its 30,000 streetlights
-Town Energy Committee
-electricity reduction program
-adopting a number of in-house procedures to lower energy
--------------------------------------------------------------------------------------
“We have no higher obligation than to protect our environment, reduce our carbon
footprint, and leave the Town in the best shape we know how for future generations,"
-Statement from Councilman
Eco-friendly, energy efficient, lighting solutions…think green
16. CASE STUDY
Manufacturer of Fire & Emergency Vehicles
Changes to Induction Lighting
Application:
* previously had 400W Metal Halide fixtures.
* Installed 200W induction lights which replaced the old Metal Halide Fixtures.
Testimonial
“We are extremely pleased with our new lights. Our production staff which includes
welders, fabricators and mechanics see much better than before, resulting in
improved quality and higher productivity. In addition we saved over 50% on our
lighting energy costs and the 10 year warranty has eliminated the costly lamp and
ballast replacements we had before. I highly recom m end induction lighting to
other com panies.”
-President
17. CASE STUDY
Hospital Application:
Application 1:
Radiology Office: Replaced 14 x 40w T-5 Fluorescent with 4 x 40w Magnetic
Induction lamps & ballasts. Reduced energy consumption from 560w to 160w
Application 2:
Maintenance Dept. & Laundry Room: Replacing fixtures that contain 2 x 32w
fluorescent bulbs with 1 x 40w induction lamp. Decreasing energy consumption on
an average of 35%
Application 3:
Parking Garages: Replacing various wattages of Metal Halides, HPS & fluorescents
with half the wattage in induction lamps. Projected 10-year savings over $970,000
Testimonial:
“These lights look like the sun…”
-Facilities Manager at the hospital
18. Summary
Key Benefits of RealTime Lighting
Environmentally Friendly: contains solid amalgam mercury which is 100%
recyclable. Eliminates the high levels of mercury being added to the environment
by disposed lamps.
Energy Savings: Reduces your lighting energy consumption by 35% - 70%.
Reduced Carbon Footprint: There is a direct link between CO2 and global
warming. By using our energy saving lamps you directly reduce your
organization’s carbon footprint.
Maintenance Free: Practically maintenance free, our bulb & ballasts are
engineered to last for 100,000 hours (11.4 years running continuously). This
eliminates the maintenance costs associated with constantly re-lamping.
Eco-friendly, energy efficient, lighting solutions…think green
19. Green-Energy-Products.Com, LLC
Eco-friendly, energy efficient lighting solutions … think green
13055 SW 83rd Avenue
Pinecrest, FL 33136
Toll Free: 800-639.8796
E-mail: info@green-energy-products.com
Web: www.green-energy-products.com
attn: Mr. John Novar
Fax: 786.242.8929