2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter

  Experts Exchange > Storage > Storage Technology > SAN 101 Basics of administrating a SAN.


  SAN 101 Basics of administrating a SAN.
  AID: 2543
  Status Published

  5,950 points

  By NeilChak
  Type Best Practices
  Posted on 2010-02-25 at 08:43:38

  IBM Storage and Cisco Fabric SAN 101

  By Neil Chakrabarty
  My class notes from the class taught by David Lawrence of IBM on 30 April to May 2, 2007 and supplemented
  by screenshots of the software systems used.
  Disclaimer
  This information is provided as the understanding of a neophyte student of storage administration. No warrantee
  of accuracy or correctness is expressed or implied by this document.
  Overview of class context, applicability and topics:
  This class was presented to the System Administrators of West Virginia Department of Environmental Protection
  (WVDEP) and storage administrators from the West Virginia Office of Technology. The WVDEP organization
  had recently lost their Storage Administrator and so the class was convened to educate the remaining IT staff in
  WVDEP maintaining and managing the Storage system and Storage Area Network.

  The WVDEP head quarter’s site has an installed IBM DS4400 Mid Range Storage Subsystem with 9 Drive
  expansion units and a Cisco 9216 fabric switch along with two IBM blade centers with Q-Logic fabric switches
  internally mounted.

  The software used is a combination of Cisco’s Fabric Manager and IBM’s Storage Manager. Therefore this
  information is relevant to any system using these two softwares and even to other vendors of storage area
  networks and storage systems as the concepts will remain valid even if the actual software is different.

  San-Rack.JPG
  77 KB


  Physical Drawing of San Equipment




www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   1/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter




  Fiber tape and SANS

  Tape and Disk paths should be separate because Disk and Tape accesses are different. So do not plug Fiber
  Channel Tape Drives into the same SAN switch as your Storage Area Network with Servers accessing Disks.

  Disk are random access while tapes are streaming oriented. Tapes have high performance when data is sent at
  the correct speed and uninterrupted. However if there is a hesitation in the dataflow then the tape has to retract
  with an associated overshoot and then realign to resume writing data.

  Shoe shining is a term used to describe the repeated action of retracting and realigning.

  Typically a cache drive is used to cache data to tape systems to avoid Shoe Shining

  History, Terminology and Concepts:
  The goal of the storage area network and storage equipment is to present blocks to an Operating System (OS)
  just as traditional disk drives do.

www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   2/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter

  SCSI, SP and FP
  SCSI Small Computer System Interface and SP or SCSI Protocol was used originally for storage systems. Also
  RAID levels 1 for mirroring, 0 for striping and 5 for striping with an extra drive for check sum.

  single-init.JPG
  3 KB



  Single Initiator




  SCSCI used parallel cables, which acted like a large capacitor. As the frequency of data transmission increased
  so would the reactance, which restricted the length of SCSI cables, and also the number of drives that could be
  connected since the cables needed to be short.

  Later newer versions of SCSI became serial to eliminate this length restriction and allow the connection of more
  drives using SCSI and SP.

  Clustered-Servers.JPG
  4 KB


  Clustered Servers




  Fiber Channel Protocol FP was developed from SP.

  Central Point, Very Important to understanding the system
  Both SP and FP protocols were designed for Single Initiators. That is there would be a single computer
  on the SCSI bus that would initiate communication with the hard drives.

  In the case of a clustered server using SP there would be two or more initiators or two or more servers on
  the SCSI bus that would negotiate for communication to the drives. This resulted in a performance hit.
  In addition to clustered negation performance hits there is also the performance hit of just managing the drives
  and the raid levels for the servers. This load increases as the number of drives and SCSI busses increase
www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   3/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter



  Storage Subsystem
  The storage subsystem introduces specialized processors to reduce the load on the servers by managing the disks
  on multiple SCSI busses.

  But this results in more trouble as the hosts communicate and have to negotiate with the specialized processor for
  connection to the Storage Subsystem.

  storage-trouble.JPG
  8 KB



  Storage Trouble




  However the processor load for maintaining the RAID arrays is successfully moved from the Host servers to this
  specialized processor/ controller designed for the purpose.

  Storage Area Network
  To solve this trouble of multiple initiators and the resulting negotiations for communication we introduce a
  network switch. As soon as a fiber channel switch is included then we term the system a Storage Area Network.
   The network we term a Fabric since it is a Fiber Channel Network with FP protocols as opposed to typical
  LAN or WAN networks.
  Zones are analogous to Firewalls in LAN/Wan networks in that they are rules in Fiber Channel switch that
  control which hosts can see which other hosts and storage subsystems.

  storage-subsystem.JPG
  9 KB



  Storage Subsystem




www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   4/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter




  Zones are used to preserve the single initiator system that the FP was designed for, except for the case of
  clustered servers. In the case of clustered servers then we limit communication to just the servers in the cluster
  and the storage subsystem so that the communication negotiation is no worse than it was before we added all the
  other hosts.
  Redundancy and Storage Area Networks
  In order to have some redundancy in this increasingly vital storage system we put in a second SAN Switch and
  divide the fabric up into two fabrics an A and a B fabric.

  redundancy.JPG
  11 KB


  Fiber Redundancy




  In this way if any fiber channel lines, host adaptors or switches fail then the system will continue to operate.

  In this design then each host has two connections one to the A switch and one to the B switch to form the A and
  B Fabrics.

  The Storage subsystem controller has two connections for the A and B fabrics as well. The storage subsystem
  processor is also designed to have two internal sets of processors and connections to the drives.

  This ensures that there is enough connections for a failure of either the A or B fabric and that each fabric is
  independent of the other.
  Multi-path Drivers
  Now the hosts each have an A and B fiber channel connection to A and B switches and A and B controllers this
  results in multiple paths to communicate with the drives in the storage subsystem thought the fabric. While this is
www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   5/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter

  better for redundancy it tends to confuse host servers that expect a single path to a local drive. To solve this
  problem then we use a multi-path driver on the host to recognize that a single “drive” from the SAN may have
  multiple paths.
  Types of Multi-path drivers:
  You should only use one type of multi-path driver per host. That is use IBM’s RDAC or Q-Logic or Novell’s
  driver but not more than one per server. The drivers would interfere with each other.
  Installing OS’s in Hosts connected to the SAN for Boot
  The multi-path driver cannot be installed until the OS is installed first. During the initial install for a host OS that is
  to boot from the San then the zone is set for a single path. That is either Fabric A or B only and not both fabrics.
   If you fail to do so then the multiple paths will confuse the OS install of most operating systems. The OS will see
  a single drive as two or more drives and attempt to write to multiple drive and be confused when the other drives
  also change.

  Zoning a single path solves this confusion so that the OS can be successfully installed. Then a Multi-Path driver
  can be installed and the host re-zoned to allow a connection to both Fabric A and Fabric B.

  Some definitions:
    LUN - A LUN is virtual disk drive presented to the host from the storage sub system. It is a section of storage
  from an array defined on the storage subsystem.
    Array -An Array is a set of physical hard drives with RAID in the storage subsystem.
    Fabric -One switch and its connections.
    ISL - Inter-switch link to combine fabrics or switches
    SVC - Storage Virtualization Controller

  IBM DS4000 - Series Storage Systems
  Made by Ingenio, these storage systems are similar in many ways.

  In the DS4400 there are two sets of fiber channel modules on the back that are interchangeable. The Left side
  connects to the switches and hosts. The Right side connects to the drive shelves in an Arbitrated Loop.
  ds4400-drawing.JPG
  6 KB


  Ds4400 Drawing




  On the Left side only one connection per module can connect to a switch. If you were not using switches then
  you can connect hosts to these ports and use both ports on the module.
www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   6/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter

  Arbitrated Loop
  The arbitrated loop is a Fiber Channel protocol based on 147-device id’s, which limits the number of devices on
  the loop. The communication is similar to token ring in that a token is passed between the devices to allow
  communication by taking turns and communicating at a data rate of a Nominal 2Gb which is actually 1.7 Gbit/s or
  212.5 MB/s.
  Arbitrated loops are fast but break the loop and it stops. Therefore we have a redundant loop.

  The IBM DS4400 has four connections to the Fabric 2 A connections and 2 B connections to ensure redundant
  connection to both the A and B Fabric’s.

  Data Rates
  Data rates of fiber channel cables set a ceiling for communication speed of an individual system. The actual
  throughput for a host system is dependant on many variables including drive speeds, other host requests and
  other issues.

  Acronyms:
  FLOGIN - Fiber channel login
  FCID - Fiber channel ID translates to two sides of a loop.
  FCHUB - Fiber channel HUB.
  FCAL-loop - Fiber Channel loop
  EXP700 and EXP710’s
  The Drive shelves are connected to the DS4400 by Fiber Channel Loops as shown below

  Notice that the cables from the In port go one way across the EXP700’s and the out port goes the other way.
   This is so that if one of the Fiber channel connectors on the EXP710’s were to fail then communication would
  not stop.
  ds4400-loops.JPG
  16 KB


  dS4400 Drive Loops




  Failure mode example

www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   7/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter

  If the line between the In port on the left side of the EXP700 with loop ID 02 and the Out port on EXP700 with
  loop id 03 were to fail then that loop would only communicate from the DS4400 to EXP700 with Loop ID 01
  and Loop ID 02.

  However the second loop would still have communication to all three EXP700’s and the DS4400.

  The EXP810’s are different, amongst the differences they have a software settable ID instead of the thumb wheel
  selector like the EXP700 and EXP710’s.

  Speed: It is rare to saturate the 2GB link other parameters are more important.
  Redundancy: Both the A and B storage controllers have access to all the drives in each shelf.
  SFP a.k.a. GBIC Small Form Factor Pluggable or Gigabyte Connector are the devices that plug into each Fiber
  Channel port for the Fiber cables to connect to. They convert the optical signal into electrical signals.
  Performance and Redundancy with Array and Lun Assignment Best Practice:
  For example with 5 shelves spread the Arrays with 1 drive per shelf, so that you can loose a shelf without losing
  data. Even with Two drives of an array in a Shelf you would loose the array if you lost the shelf.
  The case against large arrays:
  Big arrays have problems with performance when drives fail. When a drive fails or is about to fail the system will
  copy data to a Hot Spare drive. The operation to fill a hot spare is resource intensive and proportional to the
  size of the array. Larger arrays have larger overhead to re-shuffle the array, which increases drive contention on
  the SCSI busses inside the Drive Shelves. Also the increased activity exercises the drives more reducing drive
  life.

  The sweet spot is 8 to 10 drives.
  What to do instead of large arrays:
  If you have a host server that needs more space than can be arranged with an array of 8 to 10 drives simply
  create more than one array. Create Luns on one or more arrays and assign them to the host server. Most server
  OS’s can create a RAID 0 between multiple Luns. Use this software raid feature to stripe across the two or
  more Luns. The net result is that the arrays will be smaller and faster to recover from drive failures and the arrays
  will be tolerant of shelf failures. OS’s do not experience very much overhead with RAID 0 so while you are
  shifting some of the workload from the Controller to your host OS this extra work load is well worth the increase
  in reliability and performance.

  How to change large arrays to a set of smaller arrays
  Create new arrays and copy the data over then delete the old array.
  Why have a SAN?
  The reasons for a SAN are it’s flexible and dynamic. You can provision a Lun on a whim. Conversely SCSI is
  not so easy to manage.
  Assignment of Hosts to Arrays Best Practice:
  Mix your busy systems with less busy systems. Do not put all your busy systems together on one array it will
  simply lead to performance problems. Better to identify what systems are busy when and spread the load over
  the arrays that you have. For example a production system used during the day can be mixed with servers that
  do night batch processing since while both are busy they are busy at different times.
  The challenge:
  The main concern for performance in a storage system is spindle or drive contention. This should be your main
  consideration for how systems and arrays are designed to reduce drive contention.
  Understanding a common Performance Problem
  The AIX operating system from IBM sends data to a SAN just as fast as it can without waiting for feedback
www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   8/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter

  from the SAN saying it’s written.
  The Windows Operating systems send data to the SAN and wait for confirmation of a write.
  This means that Windows will spend more time waiting.

  To adjust the san to perform better for windows you may consider increasing the striping on the san by reducing
  the Luns sizes and creating more Luns over more drives. That is assigning smaller Luns in different arrays to
  windows and have windows stripe (RAID 0) across them. That way windows will be able to do more work
  faster as the overall wait time will be reduced with more drives, as windows is waiting for one Lun to respond it
  will continue writing to the other Luns.

  Each operating system will have its own characteristics in this area so as you gain experience with the
  performance tools of each OS you can tell if this problem is present.

  Storage Manager
  The current version 9.16 is written in Java so that the interface is the same across operating systems.
  More info
  Lots of great books by IBM
  www.ibm.com/redbooks
  www.ibm.com/redbooks
  Drivers, and Firmware and Bios updates and more
  www.ibm.com/support
  Finding the drivers and firmware often confuses people so here is how:
  System storage
     Product Family -> Disk Systems
     DS4400
      Download
        Storage Manager
           Firmware

  Download the firmware zip files and then unpack them into an empty folder. This will create a directory tree for
  the firmware.
  Read the Readmes for dependency information.
  SAN Surfer
  Can be downloaded under the tools link. San Surfer can bypass the OS while the host is up and see Fiber
  Channel HBA information.
  Deleting a Lun and Array Defragmenter
  When you delete a Lun from an array the Storage Manager does not combine the free space automatically. To
  combine the free space you can use the Array Defragmenter option in the Storage Manager. The Array
  Defragmenter is unfortunately named in that people confuse this with the Windows Drive Defragmenter. There is
  a big difference between the two defragmenters. Windows Drive Defragmenter is used periodically to increase
  drive performance by changing the layout of data on the drive. The Array Defragmenter only combines
  unallocated free space and does nothing to improve performance.

  It is a mistake to run the Defragmenter for any other purpose than to combine unallocated free space as the
  operation of Array Defragmentation exercises the drives in the array and creates a performance hit while
  operating.
  Creating an Array
  Click on the Create new logical drives and arrays icon in the top left of the Storage Subsystem toolbar.
www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   9/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter



  This brings up the intro window below.

  subsys1.JPG
  50 KB



  Storage Managager Subsystem window




  welcome.JPG
  36 KB


  Welcome window




www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   10/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter

  Then click Next
  SpecArray.JPG
  67 KB


  Specify Array




  Choose the RAID Level
  Use either automatic or manual drives selection.
  Automatic is fine but Manual allows you to choose which drives to use.

  CreateLun.JPG
  37 KB


  Create Lun




www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   11/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter




  Then set the size and name of the first Lun to create in the Array.
  Under the customized settings you can effect read a head buffers and set controllers but just use the
  recommended settings.


  MappingSetup.JPG
  66 KB


  Create Lun - Mapping




www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   12/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter




  Next you select the Host OS Type.
  There are many host types to choose from. By the way LINUXCL stands for Linux Cluster.
  Clicking Finish creates the array and the Lun.


  LUN-Mapping2.JPG
  66 KB



  Create Lun - Mapping 2




www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   13/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter




  LUN Parameters
  By right clicking on a Lun in the Storage subsystem menu you can change the parameters of the Lun. When a
  new Lun is created the wizard stops after the commands have been issued to create the Lun but before the Lun
  has finished being created. You can see the clock icon over the Lun as creation is completing.

  One option you can change is the modification priority, which on our system defaults to a high priority. By right
  clicking on the Lun and choosing change modification priority you can set the priority down to prevent
  performance issues with your other systems on the same array.

  Another option that can be changed is the Segment Size of the Lun. Performance can be increased for some
  host systems by setting the segment size. For example Oracle block sizes should match the Segment size.
  You can choose to increase a Lun size which depending on the OS may or may not require a reboot to
  recognize. Most operating systems will not resize its partitions even if it recognizes the extra space assigned.
  Warning: Array Clock icon
  Minimize disturbances to arrays during rebuild operations such as creating arrays or immediately after a drive
  failure. Normal host access is ok but don’t pull bad drives or create or delete Luns. Or other changes from
  storage manager.
  Volume Copy
  This is an optional feature of the Storage Manager system. First create a Lun to copy to. Then use volume copy
  to copy one Lun to another Lun.

  You should then set your host system to quiess writes to the Lun to be copied or Write Suspended mode. Read
  operations are ok.

  Next sectors are copied from one Lun to the destination Lun. If a write happens then the write is done and the
  sector is copied again before the acknowledgement is sent. Bit maps are maintained to track which sectors have
  been copied to keep track of what needs to be update to keep up with reads and writes.
www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   14/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter

  Volume Copy works at the default modification priority unless you change it after it starts.
  Flash Copy / Snapshot
  This simulates a point in time copy. The goal is to make a copy of a Lun instantly as if at one particular moment
  in time. This is simulated by creating a copy area associated with the Lun at about 15 to 20% of the size of the
  Lun to simulate a copy for. Though pointer manipulation new writes are redirected to this new copy area Lun.
  Reads are also redirected to a combination of data on the original Lun and the Copy area Lun to show the
  correct data with changes. Also the old data remains on the original drive ready to copy if desired.

  DROC - Data Rate of Change generally is 3 to 5% for most hosts.
  WROC - Write Rate of Change generally 5 to 8% for most hosts.
  Profiles:
  Storage Manager has a profile feature, which shows every setting in the system. It has tabs to show subsets and
  can export to a text file.
  WWN, World Wide Port Name - A number represented in Hexadecimal sets of two digits separated by
  colons used to identify ports and hosts in a fiber channel network. For example b4:61:62

  Nodes have WWN’s and so do the ports. Some hard ware vendors keep the node name constant across all
  ports of the node while others do not. The IBM DS4400 has a consistent Host WWN.

  Storage Networking Industry Association (SNIA) - http://www.snia.org/home

  Switches:
  It’s best not to mix switch vendors in side the same SAN. However, we did we have Q-logic and Cisco
  switches. The result of mixing switches is incomplete communication in setups. Our mix works for the most part
  but some settings are not replicated from our Cisco switch to our Q-logic switches. This works well enough for
  us that we don’t worry about it. Other combinations may not be so lucky as zoning and other problems could
  result.
  Storage manager
  Storage manager - Subsystem menu
  Save Configuration option
  This option is generally not useful. You do not want to restore from this saved configuration. However it is
  useful to setup a duplicate system at a Disaster Recovery Site.
  How to enable a premium feature:
  Ask your sales agent for a key number. Enter the Key number into storage manager and a file is generated.
   Upload the file to IBM and then download another file and then load that file into Storage manager.

  Change sub-menu
  Enclosure order- allows you to change the display order to reflect your physical setup.
  Cache- Don’t make changes unless in communication with IBM support. Better to change this on the Logical
  Drive menu at the LUN level.
  Media Scan - Detects sectors about to fail. Leave this alone unless you have problems then you can increase the
  scan rate.
  Failover Alert Delay - Effects email generated by the system.
  Set controller clocks Self-explanatory.
  Storage manager - View menu
  Task Assistant- Not used.
  Mappings - Changes to the mapping tab.
  Associated Components - When a physical component is selected this option displays a list of other components
www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   15/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter

  that are associated.
  Find- Searches for a Lun name.

  Storage manager -Array Menu
  Locate an Array - make the lights blink
  Change an Array Raid Level - performs this operation online may need more drives reduces performance during
  the operation.
  Storage manager - Logical Drive (LUN) menu
  Cache Settings-
        If the Host does not utilize the Cache then disable it per Lun.

            If the Host uses all the Cache then increase the Cache size.

            Write Cache in mirrored and good for 24 hours without power. After 24 hours of power loss you will
          have corrupted data.

            To clear the cache restore power and shutdown.

            Tune the cache settings by making small changes and observing the change. For example change by 100
          or 200.

  Media Scan setting - Per LUN
  Flash Copy- Snapshot a LUN
  Storage Manager - Controller Menu
  Loop ID- Don’t change.
  IP Addresses - There are two tabs, one for controller A and one for controller B. The addresses should differ by
  1. Changing the IP’s will cause the GUI to lose connection.
  Storage Manager - Drive Menu
  Assign Hot spares- manual control of this is better. You should have no less than 2 hot spares and more if you
  can.
  Storage Manager - Advanced Menu
  Maintenance Download -
        Controller Firmware
      Can load changes and not activate them
      Can later activate or clear changes

            NVSRAM

            ESM Firmware (Shelves like EXP700, EXP710)

            Drive Firmware
          Drives cannot be updated on line.
          Stop all IO to the drives
          Can pick out individual drives
          Drives install in parallel

            Persistent Reservations - not relevant

www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   16/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter

            Place Array - On or Off line.

            Troubleshooting
          Capture state info - Useful
          Run diagnostics - Leave alone

            Recovery

            Initialize - Clear the array.

            Revive - Try to revive a drive, better to replace a drive. Do not use while rebuilding an array (Clock Icon)

            Reset - Wipe San (lose all data)

            Place- A controller on or off line

            Enable Controller data Transfer - Catch up a controller that was off line.

            Redistribute logical drives - no comment

            Defragment Array - Consolidates unallocated free space, consumes overhead does not increase
          performance.

            Check array redundancy checks


  Performance monitor
  Can be found in the storage manager subsystem menu. This is where you check for high or low cache hits to
  adjust cache sizes in the Logical Drive menu.
  Columns
  Current IO / Second and Max IO / Second - useful numbers

  Performance tuning is a Black Art as there is not much information so it’s a matter of experience and intuition.
  Looking a drive light flashing rates and patterns is useful.

  TPC - IBM’s Total Productivity Center http://www-03.ibm.com/systems/storage/software/center/index.html can
  give better historical data to base performance tuning strategies.

  Also you can write you own screen scraping software to gather the information by starting / stopping reading and
  repeat of the performance monitor data.

  The Write column is missing but is simply 100 the Read %
  Storage Manager Mapping View
  Consider the first view as a view of the shelves from the point of view of the DS4400 or Storage controller.
  Then you can think of the Mappings view as the view from the DS4400 or Storage controller looking at the
  hosts. The mappings view shows the Luns and their connections to hosts.

  The first entry Undefined Mappings shows the Luns that are not mapped to hosts.
www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   17/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter



  To define a new host
  Right Click on the Storage Subsystem and choose Define Host Group.
  Enter the name for the new host group then you can add hosts by identifying the host using HBA ID (MAC) or
  an Alias Name. You also identify the host type. Once the host is added you can move the host to another group
  or delete or rename the host.

  MappingView.JPG
  72 KB


  MappingView




  Clustered hosts
  If you assign a Lun to a host group and two or more hosts to the host group without a clustered file system then
  you will lose the data on the LUN. That is Operating systems will over write the Lun as both hosts will consider
  the Lun to be their local drive and not realize it’s shared. Clustered file systems are needed to properly share
  drives in this manner.

  The proper way to setup a cluster is to bring up one host setup the drive start the cluster software on the second
  host and change the host assignment. Better to change the host assignment then the host group.
  Adding More Storage and upgrading from EXP700 to EXP710’s
  Upgrade the EXP700 to EXP710’s
   1.) Get the system in to a total green state with no errors.
   2.) Shut down the hosts
   3.) Set the controllers to preferred paths or set the preferred path to the actual path.
www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   18/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter

    4.) Upgrade the EXP700’s
    5.) Check the drive enclosure ID’s to insure they are correct and unique.
    6.) Bring the system back up.

  Add the new storage units.
   1.) Plan for 8 shelves in one loop. There are two loops.
   2.) Shut system down
   3.) Add storage to correct loops
   4.) Check drive enclosure id’s to insure they are correct and unique.
   5.) Bring the system up.

  Remote Mirroring and Disaster Recovery
  IBM’s Remote copy feature and EMC’s SRDF/A systems mirror data to remote SANs.

  One scenario is for each write to a local SAN also write to the remote SAN and wait for a response to finish the
  write. If this happens at the speed of light then over a distance of 100Km there would be a .6 millisecond delay
  for each trip. A total of 1.2 milliseconds for a round trip along with a .8-millisecond delay for overhead for a
  total time of 2 milliseconds additional time in the transaction.

  Alternately we write and not wait for the acknowledgement but if the link were lost then we might loose write
  order integrity. IP communication does not guarantee delivery it is a best effort protocol. TCP/IP has no
  guarantee of order of delivery. Therefore buffers would be needed at both ends to re-sequence the writes into
  the correct order.

  Power fail consistency is a goal, so there would need to be a write suspend mode to wait and update when the
  correct buffers arrive.
  High performance
  How to get the most performance for your critical systems?
   Use the outer most 10% of a large number of drives. This will reduce latency. Use the other 90% of the drive
  for non-simultaneous use such as for backups.
  A good bookMark Farley Building Storage Area Networks

  Storage Area NetworksTechnically the SAN is the network for accessing Storage and not the storage its self.
   It is common usage to refer to the entire system as a SAN. However in the IBM support site Disk systems are
  treated separately from Switches where the Switches are identified as SAN components and the Disk systems
  are separate.

  Project description
  We have identified numerous areas in which our SAN can be improved. Therefore we are going to rebuild our
  zone sets using single initiator zoning and naming conventions. Our system is a production system so we will
  setup this new zoning scheme without disruption of the existing systems until we use a scheduled down time to
  switch the system over to the new zoning scheme. We will be using the CISCO 9216 managed using Fabric
  Manager and the Q-Logic switches in Blade Center.
  Switches
  Fiber channel Switches are generally comprised of sets of 4-fiber channel ports called Quads. Quads have an
  ASIC (application-specific integrated circuit) chipset associated with them internally inside the fiber channel
  switch. Various vendors create chip sets for quads. This accounts for the fiber channel switches containing
  multiples of 4 ports since the base unit of ports is a quad.
www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   19/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter



  In our environment we have 5, 16 port fiber channel switches. Two are inside each of two blade centers and are
  the Q-Logic switches. The last switch is the 16 port Cisco 9216 switch.
  Q-Logic switches
  Inside each blade center is two sixteen-port Q-Logic switches. Each Q-Logic switch has one connection to
  each of the 14 blades and two connections to the rest of the FABRIC. Inside the blade center then we associate
  one switch to the A fabric and the other switch to the B fabric.

  The lower switch is IO module 3 so we term it IO3 or BC1_IO3. Since we assign this switch to the A fabric we
  name it A_BC1_IO3. We also name each of its 2 ports for the fabric as A_BC1_IO3_P1 and
  A_BC1_IO3_P2. Similarly for the second blade center we have A_BC2_IO3_P1 and A_BC2_IO3_P2.

  CISCO Switch and V-SAN
  The CISCO switch has a feature called V-SAN. This feature causes the CISCO switch to act as though it were
  more than one switch by creating virtual switches hence virtual SANS, since the definition of a san is a fiber
  switch.

  The Default VSAN 0001 is not supposed to be assigned to ports and is meant for overall management of the
  CISCO switch.

  Naming Convention
  Logical naming conventions are useful for keeping track of the many deices in a Storage Area Network. For our
  class we will setup the Storage Area network using the following naming convention.
    A_BC1_S01
   1.) Which FABRIC A or B
   2.) Which Blade Center BC1 or BC2.
   3.) Which Slot in the blade center S01 though S14

  WWN and Blade identification
  Each blade has 2 WWN per HBA one for the HBA and one for the Q-logic switch port in the blade center. By
  connection via Telnet to the Q-Logic switches we can query the port information and determine the WWN’s of
  the ports. By knowing which port connects to which side of the Storage controller we know which Q-Logic
  swiches are A and which ones are B fabric.
     BB1Qoi_O4 amn so pr 1
      _C_lgcI_: di> hw ot

          Pr Nme:1
           ot ubr
          ------
           ------
          Amntt
           diSae                 Oln
                                  nie                           PrI
                                                                otD                      600
                                                                                          610
          AiNme
           scubr                 0                              PrWN
                                                                otW                      2:10:0d:1d:2
                                                                                          00:0c:d0:80
          AiPr
           scot                  1                              Rnigye
                                                                unnTp                    F
          CniTp
           ofgye                 F                              SPatubr
                                                                FPrNme
          DaSau
           igtts                 Pse
                                  asd                           SPeiin
                                                                FRvso
          ECnSae
           pontt                 Nn
                                  oe                            SPye
                                                                FTp                      Ntplcbe
                                                                                         oApial
          EIoesn
           psRao                 Ntplcbe
                                  oApial                        SPedr
                                                                FVno
          LnSed
           ikpe                  2bs
                                  G/                            SPedrD
                                                                FVnoI
          LnSae
           iktt                  Atv
                                  cie                           SmoiNm
                                                                yblcae                   Pr1
                                                                                         ot
          Lgntts
           oiSau                 LgeI
                                  ogdn                          SnSau
                                                                yctts                    SnAqie
                                                                                         yccurd
          Mxrdt
           aCei                  12                             Xitrnbe
                                                                mteEald                  Tu
                                                                                         re




www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   20/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter




  cisco-wwn.JPG
  86 KB



  Cisco Fabric Manager and WWNs




  Set the Enclosure names for the blades
  Using the Cisco Fabric manager we set the enclosure names for each blade, using the hosts tab of the main
  display.

  The switch interface column identifies the blade so that we can easily fill in our names into the closure name field.
   With that and knowing the Port WWN’s we can fill in the Enclosure names using out naming convention.
  Set the controllers Enclosure names
  We set the controller frame names using the right click menu when right clicking on the controller in the map view
  and choosing device attributes. Knowing the WWN of the A and B fabric.

  cisco-enclosure.JPG
  37 KB



  Cisco Fabric Manager Setting enclosure name




www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   21/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter




  Next create Aliases in the Zone database for all the blades.
  We do this without associating the WWN’s at first to save time. In fabric manager we choose the Zone menu
  and select Edit Local Zone Database. Select the alias folder in the tree view presented and use the right click
  menu to insert aliases.

  Next we associate the blades to the aliases by adding the WWN using the enclosure name we entered earlier to
  identify the blades. We can either drag from the lower pane or use the add button.


  EditZone.JPG
  114 KB



  Cisco Fabric Manager Edit Zones




www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   22/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter




  Create aliases for the controller ports and hosts not in blade centers.
  We create an alias for the A and B ports in the controller and for the ORA-BI server which is the one external
  host in the storage network. These names are A_DS4401_A1 and B_DS4401_B1 and ORA_BI.

  ports9216.JPG
  22 KB



  Ports on the Cisco 9216




  New V-SANs and Fiber channel connections
  When defining a V-San we must associate the new V-San with ports on the CISCO 9216. We will allocate
  some unused ports to build the new zones and then re connect the fiber connections and re associate the zones
  during the down time scheduled.

  This is the new connection scheme we plan to implement.
www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   23/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter



  So we create the New V-SAN using the new V-SAN button in the toolbar in Fabric manager. We assign create
  the two new V-SAN with the names A_DEP_SAN_Fabric_A1 and B_DEP_SAN_Fabric_B1 and assign them
  to unused ports on the 9216.

  Then we use device manager to start the ports.
  Then we edit the Local Zone Database and Copy the two new V-SANs so that all the zone information exists in
  both V-SANS.


  Cisco-map.JPG
  59 KB



  Cisco Map of Fabric




  ZONE SETS
  Zone set represent a file with configuration in it that describes the defined set of zones. Only one zone set can be
  active at a time. To make a change copy the active zone set make your change. Then activate the new zone set.
   This way if you make an error you can revert back to the previous zone set.
  Debugging the Fabric
  Whenever there is doubt about the fabric such as a host fails to report. Here are some steps to verify:
   1.) The HBA is turned on in its BIOS settings.
   2.) The Alias’s are correct.
   3.) The Frame name is correct.

  Note verify the above with the WWN for the HBAs and r the MAC addresses.
  Create a zone set and zones.
  We create single initiator zones, meaning one zone for each HBA in the hosts. This most closely simulates the
www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   24/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter

  environment of a simple SCSCI bus where only one host exists on the bus. Each zone we create will contain an
  HBA and a port on the controller. This way the HBA can only see one of the controllers and no other hosts.
   Even the Clustered servers are configured this way. The clustering access is taken care of in the Mappings view
  in the Storage manager.
  Moving to a new Controller
  Drives in the san have a DAC store on each disk that contains a configuration identifying the owning controller.
   When switching a single drive from one san to another the drive negotiates with the other drives and is out
  numbered so the drive switches to its new environment. If you take a shelf full of drives and move it to another
  controller then the drives remain convinced by their number and will not connect to the new controller.

  So then to move one way is to migrate an array at a time. So when the drives move they are deleted first.

  Moving to a new controller is very complex consider hiring a consultant to assist.

  Inter Switch Links
   A single line between two switches is an Inter Switch Link ISL. Two or more lines is a Trunk. Trunks require
  separate licenses to be enabled.
  FSPF Fiber Shortest Path First
  FSPF was developed by Brocade and adopted industry wide. Essentially this is a crude attempt at load
  balancing where when the connection first starts the system determines the shortest path and then never alters it.
  Buffer-to-Buffer Credits
  There is latency in the communication from hosts though the Fiber Channel network and to the drive controller
  and eventually the shelf and drive. To minimize the latency buffering is used to buffer the signals inside of each
  switch for each port. Buffer to Buffer credits then is a system used to evaluate which hosts benefit the most from
  larger buffers.
  Thus buffer space is taken from hosts that do not take advantage of the buffering and the buffers are given to the
  hosts that will use them.

  Note this is a self-adjusting system do not change it’s setting without having IBM support on the line.
  DS4800 as compared to the DS4400
  The DS4800 is a newer Storage controller than the DS4400 currently installed in WVDEP. The new controller
  uses new technology that is much faster, and therefore configured differently. The software the Storage Manager
  software is the same but the physical system is very different.

  The DS4400 has a Front top and bottom that are interchangeable for the A connections and the B connections.
   The back of the DS440 has plug-ins for fiber hubs. The fiber hubs are interchangeable. However the left side is
  for host connections and the right side is for drive connections. (See page 6)

  The DS4800 has a top and bottom that is also interchangeable but no hub modules. You can take the top half,
  flip it over and use it as the bottom half.

  The host side of the 4800 can connect up to 8 switches while the 4400 can connect to two switches or four
  hosts.

  The drive side of the 4800 has four drive loops while the 4400 have two.

  The IOP can get to the 40,000 ranges while on the DS4400 you can get to the 1,500 ranges.

www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   25/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter

  The extra drive loops are good for either more storage or for more types of storage. For example SATA drives
  can be isolated on a loop as well as other storage types.

  ds4800.JPG
  11 KB



  Ports on IBM DS4800 Storage controller




  Install a new host and connect to a Lun
  Windows Boot to SAN and Boot Lun Assignment
  Create a Lun for the boot.
  Create the Host Group for the host.
  Add the Host to the Host group and its HBA if not already created.
  Insure that the HBA is for either Fabric A or Fabric B and set the preferred path to match for a single path.
  Install Windows and press the F6 key to install drivers for the SAN.
  Use the Q-Logic driver for the HBA for boot from san available on the www.Qlogic.com site. We use the 2300
  Q Logic cards at WVDEP.

  Windows RDAC install
  You can download the RDAC install from www.ibm.com/support storage systems, product family = Disk
  Systems DS4400, download, firmware & tools, storage manager, RDAC for windows.

  Download it and extract then run the large file in the windows subdirectory. Accept the defaults next, next and
  choose HOST Install.

  MPIO Microsoft driver does not work by itself it works in conjunction with the RDAC driver from IBM.

  Connect the new host to a lun
  In storage manager select the HBA in the storage manager host view create or assign lun to the HBA and reboot
  the host.

  In the host’s device manager you will see the entry for RDAC virtual disk, which represents the connection to
  either a lun or luns.

  SAN Surfer shows the settings of the HBA card while the system is up and running.
www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   26/27
2/22/13                     SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter

  To assign a new lun
  In Storage manager right click on the lun and add an additional mapping and find the Blade to add. IE;
  BC1_S09.
  SVC Storage Virtualization Controller
  This is another specialized computer you can add to your SAN. This SVC computer understands storage so it
  does not need RDAC or other drivers to understand storage from multiple vendors.

  You can assign luns to it in a managed disk group. The SVC can then intern present portions of that assigned
  luns as new luns to hosts.

  The SVC can be connected to multiple types of sans and then present this out to other servers as needed.

  The SVC can perform remote mirroring across different SAN vendors in different locations.



  Asked On 2010-02-25 at 08:43:38    Article ID2543
  Tags Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter
  Topic Storage Technology
  Views 12,465




    About The Author
    NeilChak




    Comments
  Expert Comment
  by: AttilaKun on 2011-08-31 at 09:27:53 Comment ID: 31014

  Excellent article! Thank you for this!




www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true                   27/27

Contenu connexe

Tendances

Brocade Administration & troubleshooting
Brocade Administration & troubleshootingBrocade Administration & troubleshooting
Brocade Administration & troubleshootingprakashjjaya
 
EMC for Network Attached Storage (NAS) Backup and Recovery Using NDMP
EMC for Network Attached Storage (NAS) Backup and Recovery Using NDMPEMC for Network Attached Storage (NAS) Backup and Recovery Using NDMP
EMC for Network Attached Storage (NAS) Backup and Recovery Using NDMPEMC
 
Storage Performance Takes Off
Storage Performance Takes OffStorage Performance Takes Off
Storage Performance Takes OffIT Brand Pulse
 
Answers to Your IT Nightmares - SAS, iSCSI, or Fibre Channel?
Answers to Your IT Nightmares - SAS, iSCSI, or Fibre Channel?Answers to Your IT Nightmares - SAS, iSCSI, or Fibre Channel?
Answers to Your IT Nightmares - SAS, iSCSI, or Fibre Channel?Aventis Systems, Inc.
 
SAN BASICS..Why we will go for SAN?
SAN BASICS..Why we will go for SAN?SAN BASICS..Why we will go for SAN?
SAN BASICS..Why we will go for SAN?Saroj Sahu
 
EMC Data domain advanced features and functions
EMC Data domain advanced features and functionsEMC Data domain advanced features and functions
EMC Data domain advanced features and functionssolarisyougood
 
Netapp Deduplication concepts
Netapp Deduplication conceptsNetapp Deduplication concepts
Netapp Deduplication conceptsSaroj Sahu
 
Introduction to NVMe Over Fabrics-V3R
Introduction to NVMe Over Fabrics-V3RIntroduction to NVMe Over Fabrics-V3R
Introduction to NVMe Over Fabrics-V3RSimon Huang
 
Storage Area Networking: SAN Technology Update & Best Practice Deep Dive for ...
Storage Area Networking: SAN Technology Update & Best Practice Deep Dive for ...Storage Area Networking: SAN Technology Update & Best Practice Deep Dive for ...
Storage Area Networking: SAN Technology Update & Best Practice Deep Dive for ...EMC
 
Abhishek Mallik Storage Administrator Lead
Abhishek Mallik Storage Administrator  LeadAbhishek Mallik Storage Administrator  Lead
Abhishek Mallik Storage Administrator LeadAbhishek Mallik
 
Avamar Run Book - 5-14-2015_v3
Avamar Run Book - 5-14-2015_v3Avamar Run Book - 5-14-2015_v3
Avamar Run Book - 5-14-2015_v3Bill Oliver
 
#IBMEdge: "Not all Networks are Equal"
#IBMEdge: "Not all Networks are Equal" #IBMEdge: "Not all Networks are Equal"
#IBMEdge: "Not all Networks are Equal" Brocade
 
Emc data domain® boost integration guide
Emc data domain® boost integration guideEmc data domain® boost integration guide
Emc data domain® boost integration guideArvind Varade
 
Cisco at v mworld 2015 vmworld - cisco mds and emc xtrem_io-v2
Cisco at v mworld 2015 vmworld - cisco mds and emc xtrem_io-v2Cisco at v mworld 2015 vmworld - cisco mds and emc xtrem_io-v2
Cisco at v mworld 2015 vmworld - cisco mds and emc xtrem_io-v2ldangelo0772
 
EMC Deduplication Fundamentals
EMC Deduplication FundamentalsEMC Deduplication Fundamentals
EMC Deduplication Fundamentalsemcbaltics
 
SAN Extension Design and Solutions
SAN Extension Design and SolutionsSAN Extension Design and Solutions
SAN Extension Design and SolutionsTony Antony
 
Presentation comparing server io consolidation solution with i scsi, infini...
Presentation   comparing server io consolidation solution with i scsi, infini...Presentation   comparing server io consolidation solution with i scsi, infini...
Presentation comparing server io consolidation solution with i scsi, infini...xKinAnx
 

Tendances (20)

Storage
StorageStorage
Storage
 
Brocade Administration & troubleshooting
Brocade Administration & troubleshootingBrocade Administration & troubleshooting
Brocade Administration & troubleshooting
 
EMC for Network Attached Storage (NAS) Backup and Recovery Using NDMP
EMC for Network Attached Storage (NAS) Backup and Recovery Using NDMPEMC for Network Attached Storage (NAS) Backup and Recovery Using NDMP
EMC for Network Attached Storage (NAS) Backup and Recovery Using NDMP
 
Storage Performance Takes Off
Storage Performance Takes OffStorage Performance Takes Off
Storage Performance Takes Off
 
Resume
ResumeResume
Resume
 
Answers to Your IT Nightmares - SAS, iSCSI, or Fibre Channel?
Answers to Your IT Nightmares - SAS, iSCSI, or Fibre Channel?Answers to Your IT Nightmares - SAS, iSCSI, or Fibre Channel?
Answers to Your IT Nightmares - SAS, iSCSI, or Fibre Channel?
 
SAN BASICS..Why we will go for SAN?
SAN BASICS..Why we will go for SAN?SAN BASICS..Why we will go for SAN?
SAN BASICS..Why we will go for SAN?
 
NAS Concepts
NAS ConceptsNAS Concepts
NAS Concepts
 
EMC Data domain advanced features and functions
EMC Data domain advanced features and functionsEMC Data domain advanced features and functions
EMC Data domain advanced features and functions
 
Netapp Deduplication concepts
Netapp Deduplication conceptsNetapp Deduplication concepts
Netapp Deduplication concepts
 
Introduction to NVMe Over Fabrics-V3R
Introduction to NVMe Over Fabrics-V3RIntroduction to NVMe Over Fabrics-V3R
Introduction to NVMe Over Fabrics-V3R
 
Storage Area Networking: SAN Technology Update & Best Practice Deep Dive for ...
Storage Area Networking: SAN Technology Update & Best Practice Deep Dive for ...Storage Area Networking: SAN Technology Update & Best Practice Deep Dive for ...
Storage Area Networking: SAN Technology Update & Best Practice Deep Dive for ...
 
Abhishek Mallik Storage Administrator Lead
Abhishek Mallik Storage Administrator  LeadAbhishek Mallik Storage Administrator  Lead
Abhishek Mallik Storage Administrator Lead
 
Avamar Run Book - 5-14-2015_v3
Avamar Run Book - 5-14-2015_v3Avamar Run Book - 5-14-2015_v3
Avamar Run Book - 5-14-2015_v3
 
#IBMEdge: "Not all Networks are Equal"
#IBMEdge: "Not all Networks are Equal" #IBMEdge: "Not all Networks are Equal"
#IBMEdge: "Not all Networks are Equal"
 
Emc data domain® boost integration guide
Emc data domain® boost integration guideEmc data domain® boost integration guide
Emc data domain® boost integration guide
 
Cisco at v mworld 2015 vmworld - cisco mds and emc xtrem_io-v2
Cisco at v mworld 2015 vmworld - cisco mds and emc xtrem_io-v2Cisco at v mworld 2015 vmworld - cisco mds and emc xtrem_io-v2
Cisco at v mworld 2015 vmworld - cisco mds and emc xtrem_io-v2
 
EMC Deduplication Fundamentals
EMC Deduplication FundamentalsEMC Deduplication Fundamentals
EMC Deduplication Fundamentals
 
SAN Extension Design and Solutions
SAN Extension Design and SolutionsSAN Extension Design and Solutions
SAN Extension Design and Solutions
 
Presentation comparing server io consolidation solution with i scsi, infini...
Presentation   comparing server io consolidation solution with i scsi, infini...Presentation   comparing server io consolidation solution with i scsi, infini...
Presentation comparing server io consolidation solution with i scsi, infini...
 

Similaire à San 101 basics of administrating a san

Similaire à San 101 basics of administrating a san (20)

SAN PPT.ppt
SAN PPT.pptSAN PPT.ppt
SAN PPT.ppt
 
Storage Area Network(SAN)
Storage Area Network(SAN)Storage Area Network(SAN)
Storage Area Network(SAN)
 
San Presentation
San PresentationSan Presentation
San Presentation
 
SAN overview.pptx
SAN overview.pptxSAN overview.pptx
SAN overview.pptx
 
Challenges in Managing IT Infrastructure
Challenges in Managing IT InfrastructureChallenges in Managing IT Infrastructure
Challenges in Managing IT Infrastructure
 
network storage
network storagenetwork storage
network storage
 
Cisco UCS vs HP Virtual Connect
Cisco UCS vs HP Virtual ConnectCisco UCS vs HP Virtual Connect
Cisco UCS vs HP Virtual Connect
 
Understanding nas (network attached storage)
Understanding nas (network attached storage)Understanding nas (network attached storage)
Understanding nas (network attached storage)
 
Advanced DB chapter 2.pdf
Advanced DB chapter 2.pdfAdvanced DB chapter 2.pdf
Advanced DB chapter 2.pdf
 
T1-9-2.ppt
T1-9-2.pptT1-9-2.ppt
T1-9-2.ppt
 
Cisco --introduction-to-storage-area-networking-technologies
Cisco --introduction-to-storage-area-networking-technologiesCisco --introduction-to-storage-area-networking-technologies
Cisco --introduction-to-storage-area-networking-technologies
 
Oracle rac 10g best practices
Oracle rac 10g best practicesOracle rac 10g best practices
Oracle rac 10g best practices
 
os
osos
os
 
Spinning Brown Donuts: Why Storage Still Counts
Spinning Brown Donuts: Why Storage Still CountsSpinning Brown Donuts: Why Storage Still Counts
Spinning Brown Donuts: Why Storage Still Counts
 
Spinning Brown Donuts
Spinning Brown DonutsSpinning Brown Donuts
Spinning Brown Donuts
 
Emc
EmcEmc
Emc
 
Storage networks
Storage networksStorage networks
Storage networks
 
Storage area network
Storage area networkStorage area network
Storage area network
 
vSphere vStorage: Troubleshooting Performance
vSphere vStorage: Troubleshooting PerformancevSphere vStorage: Troubleshooting Performance
vSphere vStorage: Troubleshooting Performance
 
S016827 pendulum-swings-nola-v1710d
S016827 pendulum-swings-nola-v1710dS016827 pendulum-swings-nola-v1710d
S016827 pendulum-swings-nola-v1710d
 

San 101 basics of administrating a san

  • 1. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter Experts Exchange > Storage > Storage Technology > SAN 101 Basics of administrating a SAN. SAN 101 Basics of administrating a SAN. AID: 2543 Status Published 5,950 points By NeilChak Type Best Practices Posted on 2010-02-25 at 08:43:38 IBM Storage and Cisco Fabric SAN 101 By Neil Chakrabarty My class notes from the class taught by David Lawrence of IBM on 30 April to May 2, 2007 and supplemented by screenshots of the software systems used. Disclaimer This information is provided as the understanding of a neophyte student of storage administration. No warrantee of accuracy or correctness is expressed or implied by this document. Overview of class context, applicability and topics: This class was presented to the System Administrators of West Virginia Department of Environmental Protection (WVDEP) and storage administrators from the West Virginia Office of Technology. The WVDEP organization had recently lost their Storage Administrator and so the class was convened to educate the remaining IT staff in WVDEP maintaining and managing the Storage system and Storage Area Network. The WVDEP head quarter’s site has an installed IBM DS4400 Mid Range Storage Subsystem with 9 Drive expansion units and a Cisco 9216 fabric switch along with two IBM blade centers with Q-Logic fabric switches internally mounted. The software used is a combination of Cisco’s Fabric Manager and IBM’s Storage Manager. Therefore this information is relevant to any system using these two softwares and even to other vendors of storage area networks and storage systems as the concepts will remain valid even if the actual software is different. San-Rack.JPG 77 KB Physical Drawing of San Equipment www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 1/27
  • 2. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter Fiber tape and SANS Tape and Disk paths should be separate because Disk and Tape accesses are different. So do not plug Fiber Channel Tape Drives into the same SAN switch as your Storage Area Network with Servers accessing Disks. Disk are random access while tapes are streaming oriented. Tapes have high performance when data is sent at the correct speed and uninterrupted. However if there is a hesitation in the dataflow then the tape has to retract with an associated overshoot and then realign to resume writing data. Shoe shining is a term used to describe the repeated action of retracting and realigning. Typically a cache drive is used to cache data to tape systems to avoid Shoe Shining History, Terminology and Concepts: The goal of the storage area network and storage equipment is to present blocks to an Operating System (OS) just as traditional disk drives do. www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 2/27
  • 3. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter SCSI, SP and FP SCSI Small Computer System Interface and SP or SCSI Protocol was used originally for storage systems. Also RAID levels 1 for mirroring, 0 for striping and 5 for striping with an extra drive for check sum. single-init.JPG 3 KB Single Initiator SCSCI used parallel cables, which acted like a large capacitor. As the frequency of data transmission increased so would the reactance, which restricted the length of SCSI cables, and also the number of drives that could be connected since the cables needed to be short. Later newer versions of SCSI became serial to eliminate this length restriction and allow the connection of more drives using SCSI and SP. Clustered-Servers.JPG 4 KB Clustered Servers Fiber Channel Protocol FP was developed from SP. Central Point, Very Important to understanding the system Both SP and FP protocols were designed for Single Initiators. That is there would be a single computer on the SCSI bus that would initiate communication with the hard drives. In the case of a clustered server using SP there would be two or more initiators or two or more servers on the SCSI bus that would negotiate for communication to the drives. This resulted in a performance hit. In addition to clustered negation performance hits there is also the performance hit of just managing the drives and the raid levels for the servers. This load increases as the number of drives and SCSI busses increase www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 3/27
  • 4. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter Storage Subsystem The storage subsystem introduces specialized processors to reduce the load on the servers by managing the disks on multiple SCSI busses. But this results in more trouble as the hosts communicate and have to negotiate with the specialized processor for connection to the Storage Subsystem. storage-trouble.JPG 8 KB Storage Trouble However the processor load for maintaining the RAID arrays is successfully moved from the Host servers to this specialized processor/ controller designed for the purpose. Storage Area Network To solve this trouble of multiple initiators and the resulting negotiations for communication we introduce a network switch. As soon as a fiber channel switch is included then we term the system a Storage Area Network. The network we term a Fabric since it is a Fiber Channel Network with FP protocols as opposed to typical LAN or WAN networks. Zones are analogous to Firewalls in LAN/Wan networks in that they are rules in Fiber Channel switch that control which hosts can see which other hosts and storage subsystems. storage-subsystem.JPG 9 KB Storage Subsystem www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 4/27
  • 5. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter Zones are used to preserve the single initiator system that the FP was designed for, except for the case of clustered servers. In the case of clustered servers then we limit communication to just the servers in the cluster and the storage subsystem so that the communication negotiation is no worse than it was before we added all the other hosts. Redundancy and Storage Area Networks In order to have some redundancy in this increasingly vital storage system we put in a second SAN Switch and divide the fabric up into two fabrics an A and a B fabric. redundancy.JPG 11 KB Fiber Redundancy In this way if any fiber channel lines, host adaptors or switches fail then the system will continue to operate. In this design then each host has two connections one to the A switch and one to the B switch to form the A and B Fabrics. The Storage subsystem controller has two connections for the A and B fabrics as well. The storage subsystem processor is also designed to have two internal sets of processors and connections to the drives. This ensures that there is enough connections for a failure of either the A or B fabric and that each fabric is independent of the other. Multi-path Drivers Now the hosts each have an A and B fiber channel connection to A and B switches and A and B controllers this results in multiple paths to communicate with the drives in the storage subsystem thought the fabric. While this is www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 5/27
  • 6. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter better for redundancy it tends to confuse host servers that expect a single path to a local drive. To solve this problem then we use a multi-path driver on the host to recognize that a single “drive” from the SAN may have multiple paths. Types of Multi-path drivers: You should only use one type of multi-path driver per host. That is use IBM’s RDAC or Q-Logic or Novell’s driver but not more than one per server. The drivers would interfere with each other. Installing OS’s in Hosts connected to the SAN for Boot The multi-path driver cannot be installed until the OS is installed first. During the initial install for a host OS that is to boot from the San then the zone is set for a single path. That is either Fabric A or B only and not both fabrics. If you fail to do so then the multiple paths will confuse the OS install of most operating systems. The OS will see a single drive as two or more drives and attempt to write to multiple drive and be confused when the other drives also change. Zoning a single path solves this confusion so that the OS can be successfully installed. Then a Multi-Path driver can be installed and the host re-zoned to allow a connection to both Fabric A and Fabric B. Some definitions: LUN - A LUN is virtual disk drive presented to the host from the storage sub system. It is a section of storage from an array defined on the storage subsystem. Array -An Array is a set of physical hard drives with RAID in the storage subsystem. Fabric -One switch and its connections. ISL - Inter-switch link to combine fabrics or switches SVC - Storage Virtualization Controller IBM DS4000 - Series Storage Systems Made by Ingenio, these storage systems are similar in many ways. In the DS4400 there are two sets of fiber channel modules on the back that are interchangeable. The Left side connects to the switches and hosts. The Right side connects to the drive shelves in an Arbitrated Loop. ds4400-drawing.JPG 6 KB Ds4400 Drawing On the Left side only one connection per module can connect to a switch. If you were not using switches then you can connect hosts to these ports and use both ports on the module. www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 6/27
  • 7. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter Arbitrated Loop The arbitrated loop is a Fiber Channel protocol based on 147-device id’s, which limits the number of devices on the loop. The communication is similar to token ring in that a token is passed between the devices to allow communication by taking turns and communicating at a data rate of a Nominal 2Gb which is actually 1.7 Gbit/s or 212.5 MB/s. Arbitrated loops are fast but break the loop and it stops. Therefore we have a redundant loop. The IBM DS4400 has four connections to the Fabric 2 A connections and 2 B connections to ensure redundant connection to both the A and B Fabric’s. Data Rates Data rates of fiber channel cables set a ceiling for communication speed of an individual system. The actual throughput for a host system is dependant on many variables including drive speeds, other host requests and other issues. Acronyms: FLOGIN - Fiber channel login FCID - Fiber channel ID translates to two sides of a loop. FCHUB - Fiber channel HUB. FCAL-loop - Fiber Channel loop EXP700 and EXP710’s The Drive shelves are connected to the DS4400 by Fiber Channel Loops as shown below Notice that the cables from the In port go one way across the EXP700’s and the out port goes the other way. This is so that if one of the Fiber channel connectors on the EXP710’s were to fail then communication would not stop. ds4400-loops.JPG 16 KB dS4400 Drive Loops Failure mode example www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 7/27
  • 8. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter If the line between the In port on the left side of the EXP700 with loop ID 02 and the Out port on EXP700 with loop id 03 were to fail then that loop would only communicate from the DS4400 to EXP700 with Loop ID 01 and Loop ID 02. However the second loop would still have communication to all three EXP700’s and the DS4400. The EXP810’s are different, amongst the differences they have a software settable ID instead of the thumb wheel selector like the EXP700 and EXP710’s. Speed: It is rare to saturate the 2GB link other parameters are more important. Redundancy: Both the A and B storage controllers have access to all the drives in each shelf. SFP a.k.a. GBIC Small Form Factor Pluggable or Gigabyte Connector are the devices that plug into each Fiber Channel port for the Fiber cables to connect to. They convert the optical signal into electrical signals. Performance and Redundancy with Array and Lun Assignment Best Practice: For example with 5 shelves spread the Arrays with 1 drive per shelf, so that you can loose a shelf without losing data. Even with Two drives of an array in a Shelf you would loose the array if you lost the shelf. The case against large arrays: Big arrays have problems with performance when drives fail. When a drive fails or is about to fail the system will copy data to a Hot Spare drive. The operation to fill a hot spare is resource intensive and proportional to the size of the array. Larger arrays have larger overhead to re-shuffle the array, which increases drive contention on the SCSI busses inside the Drive Shelves. Also the increased activity exercises the drives more reducing drive life. The sweet spot is 8 to 10 drives. What to do instead of large arrays: If you have a host server that needs more space than can be arranged with an array of 8 to 10 drives simply create more than one array. Create Luns on one or more arrays and assign them to the host server. Most server OS’s can create a RAID 0 between multiple Luns. Use this software raid feature to stripe across the two or more Luns. The net result is that the arrays will be smaller and faster to recover from drive failures and the arrays will be tolerant of shelf failures. OS’s do not experience very much overhead with RAID 0 so while you are shifting some of the workload from the Controller to your host OS this extra work load is well worth the increase in reliability and performance. How to change large arrays to a set of smaller arrays Create new arrays and copy the data over then delete the old array. Why have a SAN? The reasons for a SAN are it’s flexible and dynamic. You can provision a Lun on a whim. Conversely SCSI is not so easy to manage. Assignment of Hosts to Arrays Best Practice: Mix your busy systems with less busy systems. Do not put all your busy systems together on one array it will simply lead to performance problems. Better to identify what systems are busy when and spread the load over the arrays that you have. For example a production system used during the day can be mixed with servers that do night batch processing since while both are busy they are busy at different times. The challenge: The main concern for performance in a storage system is spindle or drive contention. This should be your main consideration for how systems and arrays are designed to reduce drive contention. Understanding a common Performance Problem The AIX operating system from IBM sends data to a SAN just as fast as it can without waiting for feedback www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 8/27
  • 9. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter from the SAN saying it’s written. The Windows Operating systems send data to the SAN and wait for confirmation of a write. This means that Windows will spend more time waiting. To adjust the san to perform better for windows you may consider increasing the striping on the san by reducing the Luns sizes and creating more Luns over more drives. That is assigning smaller Luns in different arrays to windows and have windows stripe (RAID 0) across them. That way windows will be able to do more work faster as the overall wait time will be reduced with more drives, as windows is waiting for one Lun to respond it will continue writing to the other Luns. Each operating system will have its own characteristics in this area so as you gain experience with the performance tools of each OS you can tell if this problem is present. Storage Manager The current version 9.16 is written in Java so that the interface is the same across operating systems. More info Lots of great books by IBM www.ibm.com/redbooks www.ibm.com/redbooks Drivers, and Firmware and Bios updates and more www.ibm.com/support Finding the drivers and firmware often confuses people so here is how: System storage Product Family -> Disk Systems DS4400 Download Storage Manager Firmware Download the firmware zip files and then unpack them into an empty folder. This will create a directory tree for the firmware. Read the Readmes for dependency information. SAN Surfer Can be downloaded under the tools link. San Surfer can bypass the OS while the host is up and see Fiber Channel HBA information. Deleting a Lun and Array Defragmenter When you delete a Lun from an array the Storage Manager does not combine the free space automatically. To combine the free space you can use the Array Defragmenter option in the Storage Manager. The Array Defragmenter is unfortunately named in that people confuse this with the Windows Drive Defragmenter. There is a big difference between the two defragmenters. Windows Drive Defragmenter is used periodically to increase drive performance by changing the layout of data on the drive. The Array Defragmenter only combines unallocated free space and does nothing to improve performance. It is a mistake to run the Defragmenter for any other purpose than to combine unallocated free space as the operation of Array Defragmentation exercises the drives in the array and creates a performance hit while operating. Creating an Array Click on the Create new logical drives and arrays icon in the top left of the Storage Subsystem toolbar. www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 9/27
  • 10. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter This brings up the intro window below. subsys1.JPG 50 KB Storage Managager Subsystem window welcome.JPG 36 KB Welcome window www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 10/27
  • 11. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter Then click Next SpecArray.JPG 67 KB Specify Array Choose the RAID Level Use either automatic or manual drives selection. Automatic is fine but Manual allows you to choose which drives to use. CreateLun.JPG 37 KB Create Lun www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 11/27
  • 12. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter Then set the size and name of the first Lun to create in the Array. Under the customized settings you can effect read a head buffers and set controllers but just use the recommended settings. MappingSetup.JPG 66 KB Create Lun - Mapping www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 12/27
  • 13. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter Next you select the Host OS Type. There are many host types to choose from. By the way LINUXCL stands for Linux Cluster. Clicking Finish creates the array and the Lun. LUN-Mapping2.JPG 66 KB Create Lun - Mapping 2 www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 13/27
  • 14. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter LUN Parameters By right clicking on a Lun in the Storage subsystem menu you can change the parameters of the Lun. When a new Lun is created the wizard stops after the commands have been issued to create the Lun but before the Lun has finished being created. You can see the clock icon over the Lun as creation is completing. One option you can change is the modification priority, which on our system defaults to a high priority. By right clicking on the Lun and choosing change modification priority you can set the priority down to prevent performance issues with your other systems on the same array. Another option that can be changed is the Segment Size of the Lun. Performance can be increased for some host systems by setting the segment size. For example Oracle block sizes should match the Segment size. You can choose to increase a Lun size which depending on the OS may or may not require a reboot to recognize. Most operating systems will not resize its partitions even if it recognizes the extra space assigned. Warning: Array Clock icon Minimize disturbances to arrays during rebuild operations such as creating arrays or immediately after a drive failure. Normal host access is ok but don’t pull bad drives or create or delete Luns. Or other changes from storage manager. Volume Copy This is an optional feature of the Storage Manager system. First create a Lun to copy to. Then use volume copy to copy one Lun to another Lun. You should then set your host system to quiess writes to the Lun to be copied or Write Suspended mode. Read operations are ok. Next sectors are copied from one Lun to the destination Lun. If a write happens then the write is done and the sector is copied again before the acknowledgement is sent. Bit maps are maintained to track which sectors have been copied to keep track of what needs to be update to keep up with reads and writes. www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 14/27
  • 15. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter Volume Copy works at the default modification priority unless you change it after it starts. Flash Copy / Snapshot This simulates a point in time copy. The goal is to make a copy of a Lun instantly as if at one particular moment in time. This is simulated by creating a copy area associated with the Lun at about 15 to 20% of the size of the Lun to simulate a copy for. Though pointer manipulation new writes are redirected to this new copy area Lun. Reads are also redirected to a combination of data on the original Lun and the Copy area Lun to show the correct data with changes. Also the old data remains on the original drive ready to copy if desired. DROC - Data Rate of Change generally is 3 to 5% for most hosts. WROC - Write Rate of Change generally 5 to 8% for most hosts. Profiles: Storage Manager has a profile feature, which shows every setting in the system. It has tabs to show subsets and can export to a text file. WWN, World Wide Port Name - A number represented in Hexadecimal sets of two digits separated by colons used to identify ports and hosts in a fiber channel network. For example b4:61:62 Nodes have WWN’s and so do the ports. Some hard ware vendors keep the node name constant across all ports of the node while others do not. The IBM DS4400 has a consistent Host WWN. Storage Networking Industry Association (SNIA) - http://www.snia.org/home Switches: It’s best not to mix switch vendors in side the same SAN. However, we did we have Q-logic and Cisco switches. The result of mixing switches is incomplete communication in setups. Our mix works for the most part but some settings are not replicated from our Cisco switch to our Q-logic switches. This works well enough for us that we don’t worry about it. Other combinations may not be so lucky as zoning and other problems could result. Storage manager Storage manager - Subsystem menu Save Configuration option This option is generally not useful. You do not want to restore from this saved configuration. However it is useful to setup a duplicate system at a Disaster Recovery Site. How to enable a premium feature: Ask your sales agent for a key number. Enter the Key number into storage manager and a file is generated. Upload the file to IBM and then download another file and then load that file into Storage manager. Change sub-menu Enclosure order- allows you to change the display order to reflect your physical setup. Cache- Don’t make changes unless in communication with IBM support. Better to change this on the Logical Drive menu at the LUN level. Media Scan - Detects sectors about to fail. Leave this alone unless you have problems then you can increase the scan rate. Failover Alert Delay - Effects email generated by the system. Set controller clocks Self-explanatory. Storage manager - View menu Task Assistant- Not used. Mappings - Changes to the mapping tab. Associated Components - When a physical component is selected this option displays a list of other components www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 15/27
  • 16. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter that are associated. Find- Searches for a Lun name. Storage manager -Array Menu Locate an Array - make the lights blink Change an Array Raid Level - performs this operation online may need more drives reduces performance during the operation. Storage manager - Logical Drive (LUN) menu Cache Settings- If the Host does not utilize the Cache then disable it per Lun. If the Host uses all the Cache then increase the Cache size. Write Cache in mirrored and good for 24 hours without power. After 24 hours of power loss you will have corrupted data. To clear the cache restore power and shutdown. Tune the cache settings by making small changes and observing the change. For example change by 100 or 200. Media Scan setting - Per LUN Flash Copy- Snapshot a LUN Storage Manager - Controller Menu Loop ID- Don’t change. IP Addresses - There are two tabs, one for controller A and one for controller B. The addresses should differ by 1. Changing the IP’s will cause the GUI to lose connection. Storage Manager - Drive Menu Assign Hot spares- manual control of this is better. You should have no less than 2 hot spares and more if you can. Storage Manager - Advanced Menu Maintenance Download - Controller Firmware Can load changes and not activate them Can later activate or clear changes NVSRAM ESM Firmware (Shelves like EXP700, EXP710) Drive Firmware Drives cannot be updated on line. Stop all IO to the drives Can pick out individual drives Drives install in parallel Persistent Reservations - not relevant www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 16/27
  • 17. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter Place Array - On or Off line. Troubleshooting Capture state info - Useful Run diagnostics - Leave alone Recovery Initialize - Clear the array. Revive - Try to revive a drive, better to replace a drive. Do not use while rebuilding an array (Clock Icon) Reset - Wipe San (lose all data) Place- A controller on or off line Enable Controller data Transfer - Catch up a controller that was off line. Redistribute logical drives - no comment Defragment Array - Consolidates unallocated free space, consumes overhead does not increase performance. Check array redundancy checks Performance monitor Can be found in the storage manager subsystem menu. This is where you check for high or low cache hits to adjust cache sizes in the Logical Drive menu. Columns Current IO / Second and Max IO / Second - useful numbers Performance tuning is a Black Art as there is not much information so it’s a matter of experience and intuition. Looking a drive light flashing rates and patterns is useful. TPC - IBM’s Total Productivity Center http://www-03.ibm.com/systems/storage/software/center/index.html can give better historical data to base performance tuning strategies. Also you can write you own screen scraping software to gather the information by starting / stopping reading and repeat of the performance monitor data. The Write column is missing but is simply 100 the Read % Storage Manager Mapping View Consider the first view as a view of the shelves from the point of view of the DS4400 or Storage controller. Then you can think of the Mappings view as the view from the DS4400 or Storage controller looking at the hosts. The mappings view shows the Luns and their connections to hosts. The first entry Undefined Mappings shows the Luns that are not mapped to hosts. www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 17/27
  • 18. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter To define a new host Right Click on the Storage Subsystem and choose Define Host Group. Enter the name for the new host group then you can add hosts by identifying the host using HBA ID (MAC) or an Alias Name. You also identify the host type. Once the host is added you can move the host to another group or delete or rename the host. MappingView.JPG 72 KB MappingView Clustered hosts If you assign a Lun to a host group and two or more hosts to the host group without a clustered file system then you will lose the data on the LUN. That is Operating systems will over write the Lun as both hosts will consider the Lun to be their local drive and not realize it’s shared. Clustered file systems are needed to properly share drives in this manner. The proper way to setup a cluster is to bring up one host setup the drive start the cluster software on the second host and change the host assignment. Better to change the host assignment then the host group. Adding More Storage and upgrading from EXP700 to EXP710’s Upgrade the EXP700 to EXP710’s 1.) Get the system in to a total green state with no errors. 2.) Shut down the hosts 3.) Set the controllers to preferred paths or set the preferred path to the actual path. www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 18/27
  • 19. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter 4.) Upgrade the EXP700’s 5.) Check the drive enclosure ID’s to insure they are correct and unique. 6.) Bring the system back up. Add the new storage units. 1.) Plan for 8 shelves in one loop. There are two loops. 2.) Shut system down 3.) Add storage to correct loops 4.) Check drive enclosure id’s to insure they are correct and unique. 5.) Bring the system up. Remote Mirroring and Disaster Recovery IBM’s Remote copy feature and EMC’s SRDF/A systems mirror data to remote SANs. One scenario is for each write to a local SAN also write to the remote SAN and wait for a response to finish the write. If this happens at the speed of light then over a distance of 100Km there would be a .6 millisecond delay for each trip. A total of 1.2 milliseconds for a round trip along with a .8-millisecond delay for overhead for a total time of 2 milliseconds additional time in the transaction. Alternately we write and not wait for the acknowledgement but if the link were lost then we might loose write order integrity. IP communication does not guarantee delivery it is a best effort protocol. TCP/IP has no guarantee of order of delivery. Therefore buffers would be needed at both ends to re-sequence the writes into the correct order. Power fail consistency is a goal, so there would need to be a write suspend mode to wait and update when the correct buffers arrive. High performance How to get the most performance for your critical systems? Use the outer most 10% of a large number of drives. This will reduce latency. Use the other 90% of the drive for non-simultaneous use such as for backups. A good bookMark Farley Building Storage Area Networks Storage Area NetworksTechnically the SAN is the network for accessing Storage and not the storage its self. It is common usage to refer to the entire system as a SAN. However in the IBM support site Disk systems are treated separately from Switches where the Switches are identified as SAN components and the Disk systems are separate. Project description We have identified numerous areas in which our SAN can be improved. Therefore we are going to rebuild our zone sets using single initiator zoning and naming conventions. Our system is a production system so we will setup this new zoning scheme without disruption of the existing systems until we use a scheduled down time to switch the system over to the new zoning scheme. We will be using the CISCO 9216 managed using Fabric Manager and the Q-Logic switches in Blade Center. Switches Fiber channel Switches are generally comprised of sets of 4-fiber channel ports called Quads. Quads have an ASIC (application-specific integrated circuit) chipset associated with them internally inside the fiber channel switch. Various vendors create chip sets for quads. This accounts for the fiber channel switches containing multiples of 4 ports since the base unit of ports is a quad. www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 19/27
  • 20. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter In our environment we have 5, 16 port fiber channel switches. Two are inside each of two blade centers and are the Q-Logic switches. The last switch is the 16 port Cisco 9216 switch. Q-Logic switches Inside each blade center is two sixteen-port Q-Logic switches. Each Q-Logic switch has one connection to each of the 14 blades and two connections to the rest of the FABRIC. Inside the blade center then we associate one switch to the A fabric and the other switch to the B fabric. The lower switch is IO module 3 so we term it IO3 or BC1_IO3. Since we assign this switch to the A fabric we name it A_BC1_IO3. We also name each of its 2 ports for the fabric as A_BC1_IO3_P1 and A_BC1_IO3_P2. Similarly for the second blade center we have A_BC2_IO3_P1 and A_BC2_IO3_P2. CISCO Switch and V-SAN The CISCO switch has a feature called V-SAN. This feature causes the CISCO switch to act as though it were more than one switch by creating virtual switches hence virtual SANS, since the definition of a san is a fiber switch. The Default VSAN 0001 is not supposed to be assigned to ports and is meant for overall management of the CISCO switch. Naming Convention Logical naming conventions are useful for keeping track of the many deices in a Storage Area Network. For our class we will setup the Storage Area network using the following naming convention. A_BC1_S01 1.) Which FABRIC A or B 2.) Which Blade Center BC1 or BC2. 3.) Which Slot in the blade center S01 though S14 WWN and Blade identification Each blade has 2 WWN per HBA one for the HBA and one for the Q-logic switch port in the blade center. By connection via Telnet to the Q-Logic switches we can query the port information and determine the WWN’s of the ports. By knowing which port connects to which side of the Storage controller we know which Q-Logic swiches are A and which ones are B fabric. BB1Qoi_O4 amn so pr 1 _C_lgcI_: di> hw ot Pr Nme:1 ot ubr ------ ------ Amntt diSae Oln nie PrI otD 600 610 AiNme scubr 0 PrWN otW 2:10:0d:1d:2 00:0c:d0:80 AiPr scot 1 Rnigye unnTp F CniTp ofgye F SPatubr FPrNme DaSau igtts Pse asd SPeiin FRvso ECnSae pontt Nn oe SPye FTp Ntplcbe oApial EIoesn psRao Ntplcbe oApial SPedr FVno LnSed ikpe 2bs G/ SPedrD FVnoI LnSae iktt Atv cie SmoiNm yblcae Pr1 ot Lgntts oiSau LgeI ogdn SnSau yctts SnAqie yccurd Mxrdt aCei 12 Xitrnbe mteEald Tu re www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 20/27
  • 21. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter cisco-wwn.JPG 86 KB Cisco Fabric Manager and WWNs Set the Enclosure names for the blades Using the Cisco Fabric manager we set the enclosure names for each blade, using the hosts tab of the main display. The switch interface column identifies the blade so that we can easily fill in our names into the closure name field. With that and knowing the Port WWN’s we can fill in the Enclosure names using out naming convention. Set the controllers Enclosure names We set the controller frame names using the right click menu when right clicking on the controller in the map view and choosing device attributes. Knowing the WWN of the A and B fabric. cisco-enclosure.JPG 37 KB Cisco Fabric Manager Setting enclosure name www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 21/27
  • 22. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter Next create Aliases in the Zone database for all the blades. We do this without associating the WWN’s at first to save time. In fabric manager we choose the Zone menu and select Edit Local Zone Database. Select the alias folder in the tree view presented and use the right click menu to insert aliases. Next we associate the blades to the aliases by adding the WWN using the enclosure name we entered earlier to identify the blades. We can either drag from the lower pane or use the add button. EditZone.JPG 114 KB Cisco Fabric Manager Edit Zones www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 22/27
  • 23. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter Create aliases for the controller ports and hosts not in blade centers. We create an alias for the A and B ports in the controller and for the ORA-BI server which is the one external host in the storage network. These names are A_DS4401_A1 and B_DS4401_B1 and ORA_BI. ports9216.JPG 22 KB Ports on the Cisco 9216 New V-SANs and Fiber channel connections When defining a V-San we must associate the new V-San with ports on the CISCO 9216. We will allocate some unused ports to build the new zones and then re connect the fiber connections and re associate the zones during the down time scheduled. This is the new connection scheme we plan to implement. www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 23/27
  • 24. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter So we create the New V-SAN using the new V-SAN button in the toolbar in Fabric manager. We assign create the two new V-SAN with the names A_DEP_SAN_Fabric_A1 and B_DEP_SAN_Fabric_B1 and assign them to unused ports on the 9216. Then we use device manager to start the ports. Then we edit the Local Zone Database and Copy the two new V-SANs so that all the zone information exists in both V-SANS. Cisco-map.JPG 59 KB Cisco Map of Fabric ZONE SETS Zone set represent a file with configuration in it that describes the defined set of zones. Only one zone set can be active at a time. To make a change copy the active zone set make your change. Then activate the new zone set. This way if you make an error you can revert back to the previous zone set. Debugging the Fabric Whenever there is doubt about the fabric such as a host fails to report. Here are some steps to verify: 1.) The HBA is turned on in its BIOS settings. 2.) The Alias’s are correct. 3.) The Frame name is correct. Note verify the above with the WWN for the HBAs and r the MAC addresses. Create a zone set and zones. We create single initiator zones, meaning one zone for each HBA in the hosts. This most closely simulates the www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 24/27
  • 25. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter environment of a simple SCSCI bus where only one host exists on the bus. Each zone we create will contain an HBA and a port on the controller. This way the HBA can only see one of the controllers and no other hosts. Even the Clustered servers are configured this way. The clustering access is taken care of in the Mappings view in the Storage manager. Moving to a new Controller Drives in the san have a DAC store on each disk that contains a configuration identifying the owning controller. When switching a single drive from one san to another the drive negotiates with the other drives and is out numbered so the drive switches to its new environment. If you take a shelf full of drives and move it to another controller then the drives remain convinced by their number and will not connect to the new controller. So then to move one way is to migrate an array at a time. So when the drives move they are deleted first. Moving to a new controller is very complex consider hiring a consultant to assist. Inter Switch Links A single line between two switches is an Inter Switch Link ISL. Two or more lines is a Trunk. Trunks require separate licenses to be enabled. FSPF Fiber Shortest Path First FSPF was developed by Brocade and adopted industry wide. Essentially this is a crude attempt at load balancing where when the connection first starts the system determines the shortest path and then never alters it. Buffer-to-Buffer Credits There is latency in the communication from hosts though the Fiber Channel network and to the drive controller and eventually the shelf and drive. To minimize the latency buffering is used to buffer the signals inside of each switch for each port. Buffer to Buffer credits then is a system used to evaluate which hosts benefit the most from larger buffers. Thus buffer space is taken from hosts that do not take advantage of the buffering and the buffers are given to the hosts that will use them. Note this is a self-adjusting system do not change it’s setting without having IBM support on the line. DS4800 as compared to the DS4400 The DS4800 is a newer Storage controller than the DS4400 currently installed in WVDEP. The new controller uses new technology that is much faster, and therefore configured differently. The software the Storage Manager software is the same but the physical system is very different. The DS4400 has a Front top and bottom that are interchangeable for the A connections and the B connections. The back of the DS440 has plug-ins for fiber hubs. The fiber hubs are interchangeable. However the left side is for host connections and the right side is for drive connections. (See page 6) The DS4800 has a top and bottom that is also interchangeable but no hub modules. You can take the top half, flip it over and use it as the bottom half. The host side of the 4800 can connect up to 8 switches while the 4400 can connect to two switches or four hosts. The drive side of the 4800 has four drive loops while the 4400 have two. The IOP can get to the 40,000 ranges while on the DS4400 you can get to the 1,500 ranges. www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 25/27
  • 26. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter The extra drive loops are good for either more storage or for more types of storage. For example SATA drives can be isolated on a loop as well as other storage types. ds4800.JPG 11 KB Ports on IBM DS4800 Storage controller Install a new host and connect to a Lun Windows Boot to SAN and Boot Lun Assignment Create a Lun for the boot. Create the Host Group for the host. Add the Host to the Host group and its HBA if not already created. Insure that the HBA is for either Fabric A or Fabric B and set the preferred path to match for a single path. Install Windows and press the F6 key to install drivers for the SAN. Use the Q-Logic driver for the HBA for boot from san available on the www.Qlogic.com site. We use the 2300 Q Logic cards at WVDEP. Windows RDAC install You can download the RDAC install from www.ibm.com/support storage systems, product family = Disk Systems DS4400, download, firmware & tools, storage manager, RDAC for windows. Download it and extract then run the large file in the windows subdirectory. Accept the defaults next, next and choose HOST Install. MPIO Microsoft driver does not work by itself it works in conjunction with the RDAC driver from IBM. Connect the new host to a lun In storage manager select the HBA in the storage manager host view create or assign lun to the HBA and reboot the host. In the host’s device manager you will see the entry for RDAC virtual disk, which represents the connection to either a lun or luns. SAN Surfer shows the settings of the HBA card while the system is up and running. www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 26/27
  • 27. 2/22/13 SAN 101 Basics of administrating a SAN.: Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter To assign a new lun In Storage manager right click on the lun and add an additional mapping and find the Blade to add. IE; BC1_S09. SVC Storage Virtualization Controller This is another specialized computer you can add to your SAN. This SVC computer understands storage so it does not need RDAC or other drivers to understand storage from multiple vendors. You can assign luns to it in a managed disk group. The SVC can then intern present portions of that assigned luns as new luns to hosts. The SVC can be connected to multiple types of sans and then present this out to other servers as needed. The SVC can perform remote mirroring across different SAN vendors in different locations. Asked On 2010-02-25 at 08:43:38 Article ID2543 Tags Fiber Channel Storage IBM DS4400 CISCO 9216 EXP710 BladeCenter Topic Storage Technology Views 12,465 About The Author NeilChak Comments Expert Comment by: AttilaKun on 2011-08-31 at 09:27:53 Comment ID: 31014 Excellent article! Thank you for this! www.experts-exchange.com/Storage/Storage_Technology/A_2543-SAN-101-Basics-of-administrating-a-SAN.html?printer=true 27/27