1800 °C Muffle Furnace offer heating area and include a ceramic shelf to double furnace load capacity. Highly thermal-efficient ceramic insulation surrounding the chamber achieves maximum energy efficiency. A built-in venting system removes contaminants and moisture. For More Information Please Logon http://goo.gl/SPzT1r
2. 1800 °C Muffle Furnace offer heating area and include a ceramic shelf to double furnace
load capacity. Highly thermal-efficient ceramic insulation surrounding the chamber achieves
maximum energy efficiency. A built-in venting system removes contaminants and moisture.
Door safety switch provides operator protection by cutting power to heating elements when
door is opened. It features a digital programmable control and is available with a single stored
program of eight segments. All furnaces utilize a mechanical Over Temperature Protection
relay.
1800 °C Muffle Furnace offer heating area and include a ceramic shelf to double furnace load
capacity. Highly thermal-efficient ceramic insulation surrounding the chamber achieves
maximum energy efficiency. A built-in venting system removes contaminants and moisture.
Door safety switch provides operator protection by cutting power to heating elements when
door is opened. It features a digital programmable control and is available with a single stored
program of eight segments. All furnaces utilize a mechanical Over Temperature Protection
relay.
The furnace consists of high quality
alumina fibre brick and Kathnal Super-
1800 MoSi2 heating elements with
double layer case. . This Compact Muffle
furnace is ideal for many laboratory
applications. The heating elements are
encased in quartz glass tubes making
them reliable partners for a variety of
applications.These furnaces use open
coil heating element on both sides of the
heating chamber to allow fast heating with minimal
O
1800 C BENCH TOP
MUFFLE FURNACE
R
TECHNOCRACY PVT. LTD.
3. TECHNOCRACY PVT. LTD.
R
Ÿ Units feature are double-walled
Ÿ Rust-free
Ÿ Textured stainless steel exteriors which ensure low external temperatures and
high stability.
Ÿ Door safety switch protects operator by removing power to the heating elements
upon opening the door
Ÿ Thermocouple break protection cuts power to the heating elements, preventing a
thermocouple failure runaway condition.
SALIENT FEATURES
temperature gradient. This energy efficiency is enhanced through the use of high
thermal-efficient ceramic insulation surrounding the chamber. The free-floating,
ceramic fibre door includes a chamber plug that prevents heat loss around the door by
totally sealing when the spring-loaded door is closed.
The digital single set point control features a single ramp to set point and a dwell, again
with a single display but also with a mechanical Over Temperature Protection relay.
The digital programmable control features 1 stored program with 8 segments, along
with RS232 communications. This microprocessor control features adjustable over-
temperature protection, sensor-break protection, and digital readout of both set point
and muffle furnace temperature.
4. R
TECHNOCRACY PVT. LTD.
Furnace Construction
Inside Chamber Size
Standard Working
Temperature
Maximum Working
Temperature
Double shell steel case with cooling fan to keep outside case cool
High purity alumina fiber insulation for max. energy saving ZrO2
(YSZ) coating inside chamber for longer service life.
160 x 150 x 150mm (6.3" x 5.9" x 5.9"), 3.6L
1600oC or 3092°F (continuous )
1700oC or 3812°F (< 3 hours)
PID automatic control via SCR (Silicon Controlled Rectifier)
power control, e.g. current limiting phase angle fired the resistor
with 51 steps programmable.Self-tuning and built in protection
from over-heated and broken thermal couple. Please click here to
learn why SCR is more accurate than SSR (Solid State Relay)
0 ~20°C / min (suggestion =< 10°C)
+/- 1 °C
+/- 5°C over 120 mm (5") @ 1700°C. +/- 2°C over 80 mm (3")
1700°C
Kanthal Super-1800 grade MoSi2 (4 pcs U shape)
TECHNICAL SPECIFICATIONS
Heating Element
Temperature uniformity
Temperature Accuracy
Heating Rate
Temperature Control
5. TECHNOCRACY PVT. LTD.
R
TECHNICAL SPECIFICATIONS
B Type (Pt-Rh to Pt-Rh) with Alumina tube
AC 208V-240V single phase, 50/60 Hz (50A air breaker required)
+/- 1 oC
4 KW
10 feet length 10-3 AWG heavy duty UL approven power cable is
included Extra length cable can be ordered by click picture below
Plug is not included. You can order from your local haedware
store according to female plug in your lab, or order from link below
(30A plug)
515 x 500 x 730 mm (20.28" x 20" x 28.75")
46 kg(100 lbs)
One year limited warranty (Consumable parts such as
thermocouple, o-rings and heating elements are not covered by
the warranty, please order the replacements at related products
below.)
CE certified
45" x 45"x 45"
145 lbs
Thermocouple
Working Voltage
Max. Power
Power cable & plug
Shipping Weight
Shipping dimensions
Certificate
Warranty
Net Weight
Outside Size
6. SALES OFFICE (HONG KONG)
SHOWROOM
SALES OFFICE (RUSSIA)
Unit D 28 11/F Wing Tat Comm,Bidg 97, Bonham Strand East,
Sheung Wan, Hong Kong (PRC)
Tel.: 0086-13929598046 0086- 18922303099
E-mail.: hk@acmasindia.com
J-284 Sector 1 Bawana Industrial Estate, Bawana,
Delhi, INDIA-110039
Tel.: 0091-0-9312219738 (M) +91- 9717741167
E-mail.: info@acmasindia.com
Inmed Trade Street Ozerkovsky Embankment,
Unit No 50, Straine- 1, Off- 502, Moscow, Russia
E-mail.: info@acmasindia.com
Tel.: 0049- 79592345 | Email: russia@acmasindia.com
TECHNOCRACY PVT. LTD.
www.acmasindia.com | www.cleanroom-equipments.com | www.lab-furnaces.com
An ISO 9001 : 2208 | ISO 14001 : 2008 | ISO 13485
WHO: GMP Products | GLP Compliant Products
SALES OFFICE (INDIA)
th
Office no. 506 & 507, 5 Floor, Plot no.- C-9,
Pearls Best Height-II, Netaji Subhash Place,
Pitam Pura, Delhi- 110034
Land Line No.: +91 - 11- 47619688,
Fax: +91-11-47619788
E-mail.: info@acmasindia.com