Krypton® Multi
For measuring disinfectants, pH and temperature - optional
ORP and 5th measuring input.
subjects to alterations - version 07/2015
Online measuring board for measuring disinfectants, pH and temperature - optional ORP
and 5th selectable measuring input
Worldwide access by internal webserver (LAN or WLAN)
Krypton® Multi
Applications
Disinfection
Process Water
Drinking Water / Beverages
Description
The measuring system Krypton® Multi includes all you need for disinfection and pH measurement: instrument,
sensors, assembly and wiring. The system is used for measuring and control in industrial desinfectants applications
like in breweries, water works or cooling towers. The integrated modular assembly Argon® Stabiflow ensures a
constant flow of approx. 30 l/h. As a consequence the system provides stable, precise and reliable measuring
values. Flow fluctuations not any longer shown up in your measuring curves as long as you guarantee a water inlet
above 35 l/h. The entry level version of Neon® Multi is equipped with 3 measurements: disinfection, pH, and
temperature. The disinfection measuring input can be configured to measure free Chlorine, Chlorine dioxide, Ozone
or Hydrogen peroxide via menu. The measuring range is adjustable. An ORP measurement can be added and even
a 5th measuring input for total Chlorine. The entry level version of Neon® Multi offers 6 digital inputs and 8 potential
free CO relays as control or as alarm relay. The instruments offers PID as well as 3 point control function with and
without position feedback. Neon® Multi is expandable through software upgrades or add on modules. It is possible
to add up to five analog outputs, Modbus, automatic sensor cleaning ASR® and datalogger. The complete system is
pressure resistant up to 6 bar (at 20°C) and brine resistant.
Krypton® Multi
For measuring disinfectants, pH and temperature - optional
ORP and 5th measuring input.
subjects to alterations - version 07/2015
Particular characteristics
85.. 265 V AC power supply
90x50 mm touch display
Real time clock
Pressure proofed to 6 bar (at 20°C without TCl)
Precise measurement by a constant flow
Up to 3 separate PID controller for disinfectant measurement, pH and the 5th measuring
input (Total Chlorine)
disinfection measurement or pH: 3-point-controller with or without position feedback
Dosage check
Up to 4 potential-free alarm relais
Lower and upper limit value with delay for each measuring parameter adjustable and
assignable to the alarm relay
Alerts selectable for alarm relay
Eventlog and event help
Safety by autolock function
4 user level by password function
Individual user codes are possible
Intuitive operation with touch screen and graphical menu
Functional upgrade by activation code or with modules
SD card function: firmware update, configuration and diagnosis file
Test menu for wiring check
Screensaver: Auto-shut-off of LCD backlight
Automativ pH-compensation for free Chlorine measurement
Automatic or manual temperature compensation
Display of organic Chlorine by combination of total Chlorine and free Chlorine
measurement
Option: 5th measuring input fot total Chlorine
Option: ASR® automatic sensor cleaning
Option: 5 mA outputs 0/4 to 20 mA adjustable with fault current
Option: RS 485 Modbus RTU
Option: data log function - storage of all measuring data up to one year and trendview of
stored data
Krypton® Multi
For measuring disinfectants, pH and temperature - optional
ORP and 5th measuring input.
subjects to alterations - version 07/2015
Interface diagram
Technical data
Measuring parameter
Free Chlorine, Chlorine dioxide,
Ozone
0.. 1000 µg/l
0.. 5.00 mg/l
0.. 10.00 mg/l
Free Chlorine, Chlorine dioxide 0.. 20.00 mg/l
pH-value 0.. 14.00 pH
ORP -1500.. 1500 mV
Temperature 0.. 50 °C
Hydrogen Peroxide 0.. 30 mg/l
Total Chlorine 0.. 10 mg/l
Krypton® Multi
For measuring disinfectants, pH and temperature - optional
ORP and 5th measuring input.
subjects to alterations - version 07/2015
Input characteristics
Accuracy +/-2% of measuring range limit
Temperature measuring range 0.. 50°C
Temperature coefficient 0,0.. 8,0 %/K adjustable
Digital input Flow control, external controller stop, 2x level control, activation 2nd control
parameter set
Ambient conditions pH-range 6.. 8 pH (free Chlorine) 6.. 9 pH
(Chlorine dioxide, Ozone, Hydrogen
peroxide) total Chlorine depending on
sensor
Flow >20 l/h, constant
Min. conductivity > 150 S/cm
Temperature Depending on sensor, assembly and
reference measurement
Output characteristics
Alarm relay up to 4 potentialfree CO, max. 250 V; 2 A, 550 VA
Output signal Optional: 5 x 0/4.. 20 mA (scaleable, galvanically isolated)
Load 500 Ohm
Registration range Scaleable within the measuring range
Storage media Accessory: SD card up to 2 GB - Industry standard
Baud rate 19200 kbs (Modbus)
Data format 8 bit
Power supply
Line voltage 85.. 265 V AC / DC, 50.. 60 Hz
Power consumption 10 VA
Ambient conditions
Temperature Storage -20.. +65°C, exception sensor 0..
+30°C
Operation 0.. +50°C
Humidity max. 90% rH at 40°C (non-condensing)
Protection class Wall mounted IP 65
Controller
Control mode on/off controller (adjustable hysteresis) P/PI/PID controller (pulse-pause,
pulse-frequency or continous output) 3-point controller with or without position
feedback, coagulation dosing optional)
Relay 8 relays, each a potential-free CO contact, max. 250 V, 2A, 550 VA
Start delay 0.. 200 sec till controller active
Controller stop Digital input
Krypton® Multi
For measuring disinfectants, pH and temperature - optional
ORP and 5th measuring input.
subjects to alterations - version 07/2015
Design configuration
Material Board: PVC, assembly: PMMA, cocks: PP, PVC, instrument: ABS, sensors:
glass
Dimensions 400 x 700 mm
Connection cable inlet: 2x M16, 2x M12 + optional: 2x M12 und 1x M25 plug-in terminal:
rigid/ flexible 0,14 - 1,5 mm² relays / power supply - starr/flexibel 0,2-1 /
0,2-1,5 mm² distribution block 0,5-2,5/ 0,5-2,5 mm²
Mechanical drawing
Krypton® Multi
For measuring disinfectants, pH and temperature - optional
ORP and 5th measuring input.
subjects to alterations - version 07/2015
Order information
Choose the components you need and that´s how your "assembly version" is designed. We will have to technically
inspect and approve a free combination of individual key features.
Krypton® Multi
For measuring disinfectants, pH and temperature - optional
ORP and 5th measuring input.
subjects to alterations - version 07/2015
Accessories
hand-held units
Radon Des- pH The Radon photometer is used for measuring of
Chlorine, Chlorine dioxide, Ozone, Hydrogen peroxide
and pH. Accurate and consistent results are obtained
quickly. Delivery contents is everything neede to
measure Chlorine, Chlorine dioxide and Ozone. The
delivery content conains evrything needed for
measuring Chlorine, Chlorine dioxide and Ozone. For
measurement of Hydrogen peroxide you need a
H2O2-addon and for the pH measurement the
reagent phenolred.
accessories
Test Plug DES With the test plug you can check the function and
connection of our disinfection measurement - not for
Total Chlorine measurement (not TCl).
Powered by TCPDF (www.tcpdf.org)

Contenu connexe

En vedette

Intelligent Sensor Management For Inline Process Analytics
Intelligent Sensor Management For Inline Process AnalyticsIntelligent Sensor Management For Inline Process Analytics
Intelligent Sensor Management For Inline Process AnalyticsAlliance Technical Sales, Inc.
 
Line Card for Alliance Technical Sales - Updated 12/2016
Line Card for Alliance Technical Sales - Updated 12/2016Line Card for Alliance Technical Sales - Updated 12/2016
Line Card for Alliance Technical Sales - Updated 12/2016Alliance Technical Sales, Inc.
 
Technical Reference for Thermocouples and Reistance Temperature Detectors (RTD)
Technical Reference for Thermocouples and Reistance Temperature Detectors (RTD)Technical Reference for Thermocouples and Reistance Temperature Detectors (RTD)
Technical Reference for Thermocouples and Reistance Temperature Detectors (RTD)Alliance Technical Sales, Inc.
 
Moisture, Hydrogen, and Temperature Measurement in Electrical Transformers
Moisture, Hydrogen, and Temperature Measurement in Electrical TransformersMoisture, Hydrogen, and Temperature Measurement in Electrical Transformers
Moisture, Hydrogen, and Temperature Measurement in Electrical TransformersAlliance Technical Sales, Inc.
 
Pharmaceutical Manufacturing Case Study: Refurbish Old Bioreactor
Pharmaceutical Manufacturing Case Study: Refurbish Old BioreactorPharmaceutical Manufacturing Case Study: Refurbish Old Bioreactor
Pharmaceutical Manufacturing Case Study: Refurbish Old BioreactorAlliance Technical Sales, Inc.
 
Magnetostrictive Liquid Level Transmitter for Process Measurement and Control
Magnetostrictive Liquid Level Transmitter for Process Measurement and ControlMagnetostrictive Liquid Level Transmitter for Process Measurement and Control
Magnetostrictive Liquid Level Transmitter for Process Measurement and ControlAlliance Technical Sales, Inc.
 

En vedette (9)

Intelligent Sensor Management For Inline Process Analytics
Intelligent Sensor Management For Inline Process AnalyticsIntelligent Sensor Management For Inline Process Analytics
Intelligent Sensor Management For Inline Process Analytics
 
Line Card for Alliance Technical Sales - Updated 12/2016
Line Card for Alliance Technical Sales - Updated 12/2016Line Card for Alliance Technical Sales - Updated 12/2016
Line Card for Alliance Technical Sales - Updated 12/2016
 
Jogler magnetic level gauge brochure
Jogler magnetic level gauge brochureJogler magnetic level gauge brochure
Jogler magnetic level gauge brochure
 
Technical Reference for Thermocouples and Reistance Temperature Detectors (RTD)
Technical Reference for Thermocouples and Reistance Temperature Detectors (RTD)Technical Reference for Thermocouples and Reistance Temperature Detectors (RTD)
Technical Reference for Thermocouples and Reistance Temperature Detectors (RTD)
 
PID Controllers from Precision Digital
PID Controllers from Precision DigitalPID Controllers from Precision Digital
PID Controllers from Precision Digital
 
Moisture, Hydrogen, and Temperature Measurement in Electrical Transformers
Moisture, Hydrogen, and Temperature Measurement in Electrical TransformersMoisture, Hydrogen, and Temperature Measurement in Electrical Transformers
Moisture, Hydrogen, and Temperature Measurement in Electrical Transformers
 
Optimizing chemcial industry processes
Optimizing chemcial industry processesOptimizing chemcial industry processes
Optimizing chemcial industry processes
 
Pharmaceutical Manufacturing Case Study: Refurbish Old Bioreactor
Pharmaceutical Manufacturing Case Study: Refurbish Old BioreactorPharmaceutical Manufacturing Case Study: Refurbish Old Bioreactor
Pharmaceutical Manufacturing Case Study: Refurbish Old Bioreactor
 
Magnetostrictive Liquid Level Transmitter for Process Measurement and Control
Magnetostrictive Liquid Level Transmitter for Process Measurement and ControlMagnetostrictive Liquid Level Transmitter for Process Measurement and Control
Magnetostrictive Liquid Level Transmitter for Process Measurement and Control
 

Plus de Alliance Technical Sales, Inc.

Jogler Magnetic Level Gauge, Magnetostrictive Level Transmitter, and Laser Le...
Jogler Magnetic Level Gauge, Magnetostrictive Level Transmitter, and Laser Le...Jogler Magnetic Level Gauge, Magnetostrictive Level Transmitter, and Laser Le...
Jogler Magnetic Level Gauge, Magnetostrictive Level Transmitter, and Laser Le...Alliance Technical Sales, Inc.
 
Pharmaceutical Waters Guide for Regulatory Compliance, Analysis and Real-Time...
Pharmaceutical Waters Guide for Regulatory Compliance, Analysis and Real-Time...Pharmaceutical Waters Guide for Regulatory Compliance, Analysis and Real-Time...
Pharmaceutical Waters Guide for Regulatory Compliance, Analysis and Real-Time...Alliance Technical Sales, Inc.
 
Analytical Measurement Solutions for Optimization of Your Brewing Process
Analytical Measurement Solutions for Optimization of Your Brewing ProcessAnalytical Measurement Solutions for Optimization of Your Brewing Process
Analytical Measurement Solutions for Optimization of Your Brewing ProcessAlliance Technical Sales, Inc.
 
Jogler Liquid Level Gauges, Indicators and Transmitters
Jogler Liquid Level Gauges, Indicators and TransmittersJogler Liquid Level Gauges, Indicators and Transmitters
Jogler Liquid Level Gauges, Indicators and TransmittersAlliance Technical Sales, Inc.
 
Laser Level Transmitter for Process Measurement and Control
Laser Level Transmitter for Process Measurement and ControlLaser Level Transmitter for Process Measurement and Control
Laser Level Transmitter for Process Measurement and ControlAlliance Technical Sales, Inc.
 
Surface Temperature Sensors and Transmitters for Industrial Applications
Surface Temperature Sensors and Transmitters for Industrial ApplicationsSurface Temperature Sensors and Transmitters for Industrial Applications
Surface Temperature Sensors and Transmitters for Industrial ApplicationsAlliance Technical Sales, Inc.
 
Guide to Oxygen Measurement in Industrial Process Applications
Guide to Oxygen Measurement in Industrial Process ApplicationsGuide to Oxygen Measurement in Industrial Process Applications
Guide to Oxygen Measurement in Industrial Process ApplicationsAlliance Technical Sales, Inc.
 

Plus de Alliance Technical Sales, Inc. (20)

Jogler Magnetic Level Gauge, Magnetostrictive Level Transmitter, and Laser Le...
Jogler Magnetic Level Gauge, Magnetostrictive Level Transmitter, and Laser Le...Jogler Magnetic Level Gauge, Magnetostrictive Level Transmitter, and Laser Le...
Jogler Magnetic Level Gauge, Magnetostrictive Level Transmitter, and Laser Le...
 
Electric Heating and Freeze Protection Solutions
Electric Heating and Freeze Protection SolutionsElectric Heating and Freeze Protection Solutions
Electric Heating and Freeze Protection Solutions
 
Mettler Toledo Process Analytics Catalog 2018-2019
Mettler Toledo Process Analytics Catalog 2018-2019Mettler Toledo Process Analytics Catalog 2018-2019
Mettler Toledo Process Analytics Catalog 2018-2019
 
Jogler Industrial Level Measurement Products Catalog
Jogler Industrial Level Measurement Products CatalogJogler Industrial Level Measurement Products Catalog
Jogler Industrial Level Measurement Products Catalog
 
Pharmaceutical Waters Guide for Regulatory Compliance, Analysis and Real-Time...
Pharmaceutical Waters Guide for Regulatory Compliance, Analysis and Real-Time...Pharmaceutical Waters Guide for Regulatory Compliance, Analysis and Real-Time...
Pharmaceutical Waters Guide for Regulatory Compliance, Analysis and Real-Time...
 
Analytical Measurement Solutions for Optimization of Your Brewing Process
Analytical Measurement Solutions for Optimization of Your Brewing ProcessAnalytical Measurement Solutions for Optimization of Your Brewing Process
Analytical Measurement Solutions for Optimization of Your Brewing Process
 
Pre-Assembled Self-Regulating Heating Cable
Pre-Assembled Self-Regulating Heating CablePre-Assembled Self-Regulating Heating Cable
Pre-Assembled Self-Regulating Heating Cable
 
Jogler Liquid Level Gauges, Indicators and Transmitters
Jogler Liquid Level Gauges, Indicators and TransmittersJogler Liquid Level Gauges, Indicators and Transmitters
Jogler Liquid Level Gauges, Indicators and Transmitters
 
Pharmaceutical Water Instrumentation Guide
Pharmaceutical Water Instrumentation GuidePharmaceutical Water Instrumentation Guide
Pharmaceutical Water Instrumentation Guide
 
Pharmaceutical Water Guide - Instrumentation
Pharmaceutical Water Guide - InstrumentationPharmaceutical Water Guide - Instrumentation
Pharmaceutical Water Guide - Instrumentation
 
Indigo 200 Series Transmitters
Indigo 200 Series TransmittersIndigo 200 Series Transmitters
Indigo 200 Series Transmitters
 
Laser Level Transmitter for Process Measurement and Control
Laser Level Transmitter for Process Measurement and ControlLaser Level Transmitter for Process Measurement and Control
Laser Level Transmitter for Process Measurement and Control
 
Portable pH Meter for Process Measurement
Portable pH Meter for Process MeasurementPortable pH Meter for Process Measurement
Portable pH Meter for Process Measurement
 
Dissolved Solids Analyzer Refractometer
Dissolved Solids Analyzer RefractometerDissolved Solids Analyzer Refractometer
Dissolved Solids Analyzer Refractometer
 
Temperature and Relative Humidity Data Logger
Temperature and Relative Humidity Data LoggerTemperature and Relative Humidity Data Logger
Temperature and Relative Humidity Data Logger
 
TOC Total Organic Carbon Analyzer
TOC Total Organic Carbon AnalyzerTOC Total Organic Carbon Analyzer
TOC Total Organic Carbon Analyzer
 
Surface Temperature Sensors and Transmitters for Industrial Applications
Surface Temperature Sensors and Transmitters for Industrial ApplicationsSurface Temperature Sensors and Transmitters for Industrial Applications
Surface Temperature Sensors and Transmitters for Industrial Applications
 
Guide to Oxygen Measurement in Industrial Process Applications
Guide to Oxygen Measurement in Industrial Process ApplicationsGuide to Oxygen Measurement in Industrial Process Applications
Guide to Oxygen Measurement in Industrial Process Applications
 
Turbidity Standards for Turbidity Measurement
Turbidity Standards for Turbidity MeasurementTurbidity Standards for Turbidity Measurement
Turbidity Standards for Turbidity Measurement
 
Automated pH Sensor Cleaning and Calibration
Automated pH Sensor Cleaning and CalibrationAutomated pH Sensor Cleaning and Calibration
Automated pH Sensor Cleaning and Calibration
 

Dernier

HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKARHAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKARKOUSTAV SARKAR
 
Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTbhaskargani46
 
GEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLE
GEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLEGEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLE
GEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLEselvakumar948
 
DeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakesDeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakesMayuraD1
 
Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...
Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...
Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...Call Girls Mumbai
 
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...Arindam Chakraborty, Ph.D., P.E. (CA, TX)
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXssuser89054b
 
Introduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaIntroduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaOmar Fathy
 
kiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal loadkiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal loadhamedmustafa094
 
Double Revolving field theory-how the rotor develops torque
Double Revolving field theory-how the rotor develops torqueDouble Revolving field theory-how the rotor develops torque
Double Revolving field theory-how the rotor develops torqueBhangaleSonal
 
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
COST-EFFETIVE  and Energy Efficient BUILDINGS ptxCOST-EFFETIVE  and Energy Efficient BUILDINGS ptx
COST-EFFETIVE and Energy Efficient BUILDINGS ptxJIT KUMAR GUPTA
 
PE 459 LECTURE 2- natural gas basic concepts and properties
PE 459 LECTURE 2- natural gas basic concepts and propertiesPE 459 LECTURE 2- natural gas basic concepts and properties
PE 459 LECTURE 2- natural gas basic concepts and propertiessarkmank1
 
"Lesotho Leaps Forward: A Chronicle of Transformative Developments"
"Lesotho Leaps Forward: A Chronicle of Transformative Developments""Lesotho Leaps Forward: A Chronicle of Transformative Developments"
"Lesotho Leaps Forward: A Chronicle of Transformative Developments"mphochane1998
 
Online electricity billing project report..pdf
Online electricity billing project report..pdfOnline electricity billing project report..pdf
Online electricity billing project report..pdfKamal Acharya
 
A Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna MunicipalityA Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna MunicipalityMorshed Ahmed Rahath
 
Engineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planesEngineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planesRAJNEESHKUMAR341697
 
Hospital management system project report.pdf
Hospital management system project report.pdfHospital management system project report.pdf
Hospital management system project report.pdfKamal Acharya
 
Hostel management system project report..pdf
Hostel management system project report..pdfHostel management system project report..pdf
Hostel management system project report..pdfKamal Acharya
 

Dernier (20)

HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKARHAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
 
Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPT
 
GEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLE
GEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLEGEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLE
GEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLE
 
DeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakesDeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakes
 
Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...
Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...
Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...
 
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
 
Introduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaIntroduction to Serverless with AWS Lambda
Introduction to Serverless with AWS Lambda
 
kiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal loadkiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal load
 
Double Revolving field theory-how the rotor develops torque
Double Revolving field theory-how the rotor develops torqueDouble Revolving field theory-how the rotor develops torque
Double Revolving field theory-how the rotor develops torque
 
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
COST-EFFETIVE  and Energy Efficient BUILDINGS ptxCOST-EFFETIVE  and Energy Efficient BUILDINGS ptx
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
 
PE 459 LECTURE 2- natural gas basic concepts and properties
PE 459 LECTURE 2- natural gas basic concepts and propertiesPE 459 LECTURE 2- natural gas basic concepts and properties
PE 459 LECTURE 2- natural gas basic concepts and properties
 
Integrated Test Rig For HTFE-25 - Neometrix
Integrated Test Rig For HTFE-25 - NeometrixIntegrated Test Rig For HTFE-25 - Neometrix
Integrated Test Rig For HTFE-25 - Neometrix
 
"Lesotho Leaps Forward: A Chronicle of Transformative Developments"
"Lesotho Leaps Forward: A Chronicle of Transformative Developments""Lesotho Leaps Forward: A Chronicle of Transformative Developments"
"Lesotho Leaps Forward: A Chronicle of Transformative Developments"
 
Online electricity billing project report..pdf
Online electricity billing project report..pdfOnline electricity billing project report..pdf
Online electricity billing project report..pdf
 
A Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna MunicipalityA Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna Municipality
 
Engineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planesEngineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planes
 
Hospital management system project report.pdf
Hospital management system project report.pdfHospital management system project report.pdf
Hospital management system project report.pdf
 
Hostel management system project report..pdf
Hostel management system project report..pdfHostel management system project report..pdf
Hostel management system project report..pdf
 
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
 

Multivariable liquid analysis system

  • 1. Krypton® Multi For measuring disinfectants, pH and temperature - optional ORP and 5th measuring input. subjects to alterations - version 07/2015 Online measuring board for measuring disinfectants, pH and temperature - optional ORP and 5th selectable measuring input Worldwide access by internal webserver (LAN or WLAN) Krypton® Multi Applications Disinfection Process Water Drinking Water / Beverages Description The measuring system Krypton® Multi includes all you need for disinfection and pH measurement: instrument, sensors, assembly and wiring. The system is used for measuring and control in industrial desinfectants applications like in breweries, water works or cooling towers. The integrated modular assembly Argon® Stabiflow ensures a constant flow of approx. 30 l/h. As a consequence the system provides stable, precise and reliable measuring values. Flow fluctuations not any longer shown up in your measuring curves as long as you guarantee a water inlet above 35 l/h. The entry level version of Neon® Multi is equipped with 3 measurements: disinfection, pH, and temperature. The disinfection measuring input can be configured to measure free Chlorine, Chlorine dioxide, Ozone or Hydrogen peroxide via menu. The measuring range is adjustable. An ORP measurement can be added and even a 5th measuring input for total Chlorine. The entry level version of Neon® Multi offers 6 digital inputs and 8 potential free CO relays as control or as alarm relay. The instruments offers PID as well as 3 point control function with and without position feedback. Neon® Multi is expandable through software upgrades or add on modules. It is possible to add up to five analog outputs, Modbus, automatic sensor cleaning ASR® and datalogger. The complete system is pressure resistant up to 6 bar (at 20°C) and brine resistant.
  • 2. Krypton® Multi For measuring disinfectants, pH and temperature - optional ORP and 5th measuring input. subjects to alterations - version 07/2015 Particular characteristics 85.. 265 V AC power supply 90x50 mm touch display Real time clock Pressure proofed to 6 bar (at 20°C without TCl) Precise measurement by a constant flow Up to 3 separate PID controller for disinfectant measurement, pH and the 5th measuring input (Total Chlorine) disinfection measurement or pH: 3-point-controller with or without position feedback Dosage check Up to 4 potential-free alarm relais Lower and upper limit value with delay for each measuring parameter adjustable and assignable to the alarm relay Alerts selectable for alarm relay Eventlog and event help Safety by autolock function 4 user level by password function Individual user codes are possible Intuitive operation with touch screen and graphical menu Functional upgrade by activation code or with modules SD card function: firmware update, configuration and diagnosis file Test menu for wiring check Screensaver: Auto-shut-off of LCD backlight Automativ pH-compensation for free Chlorine measurement Automatic or manual temperature compensation Display of organic Chlorine by combination of total Chlorine and free Chlorine measurement Option: 5th measuring input fot total Chlorine Option: ASR® automatic sensor cleaning Option: 5 mA outputs 0/4 to 20 mA adjustable with fault current Option: RS 485 Modbus RTU Option: data log function - storage of all measuring data up to one year and trendview of stored data
  • 3. Krypton® Multi For measuring disinfectants, pH and temperature - optional ORP and 5th measuring input. subjects to alterations - version 07/2015 Interface diagram Technical data Measuring parameter Free Chlorine, Chlorine dioxide, Ozone 0.. 1000 µg/l 0.. 5.00 mg/l 0.. 10.00 mg/l Free Chlorine, Chlorine dioxide 0.. 20.00 mg/l pH-value 0.. 14.00 pH ORP -1500.. 1500 mV Temperature 0.. 50 °C Hydrogen Peroxide 0.. 30 mg/l Total Chlorine 0.. 10 mg/l
  • 4. Krypton® Multi For measuring disinfectants, pH and temperature - optional ORP and 5th measuring input. subjects to alterations - version 07/2015 Input characteristics Accuracy +/-2% of measuring range limit Temperature measuring range 0.. 50°C Temperature coefficient 0,0.. 8,0 %/K adjustable Digital input Flow control, external controller stop, 2x level control, activation 2nd control parameter set Ambient conditions pH-range 6.. 8 pH (free Chlorine) 6.. 9 pH (Chlorine dioxide, Ozone, Hydrogen peroxide) total Chlorine depending on sensor Flow >20 l/h, constant Min. conductivity > 150 S/cm Temperature Depending on sensor, assembly and reference measurement Output characteristics Alarm relay up to 4 potentialfree CO, max. 250 V; 2 A, 550 VA Output signal Optional: 5 x 0/4.. 20 mA (scaleable, galvanically isolated) Load 500 Ohm Registration range Scaleable within the measuring range Storage media Accessory: SD card up to 2 GB - Industry standard Baud rate 19200 kbs (Modbus) Data format 8 bit Power supply Line voltage 85.. 265 V AC / DC, 50.. 60 Hz Power consumption 10 VA Ambient conditions Temperature Storage -20.. +65°C, exception sensor 0.. +30°C Operation 0.. +50°C Humidity max. 90% rH at 40°C (non-condensing) Protection class Wall mounted IP 65 Controller Control mode on/off controller (adjustable hysteresis) P/PI/PID controller (pulse-pause, pulse-frequency or continous output) 3-point controller with or without position feedback, coagulation dosing optional) Relay 8 relays, each a potential-free CO contact, max. 250 V, 2A, 550 VA Start delay 0.. 200 sec till controller active Controller stop Digital input
  • 5. Krypton® Multi For measuring disinfectants, pH and temperature - optional ORP and 5th measuring input. subjects to alterations - version 07/2015 Design configuration Material Board: PVC, assembly: PMMA, cocks: PP, PVC, instrument: ABS, sensors: glass Dimensions 400 x 700 mm Connection cable inlet: 2x M16, 2x M12 + optional: 2x M12 und 1x M25 plug-in terminal: rigid/ flexible 0,14 - 1,5 mm² relays / power supply - starr/flexibel 0,2-1 / 0,2-1,5 mm² distribution block 0,5-2,5/ 0,5-2,5 mm² Mechanical drawing
  • 6. Krypton® Multi For measuring disinfectants, pH and temperature - optional ORP and 5th measuring input. subjects to alterations - version 07/2015 Order information Choose the components you need and that´s how your "assembly version" is designed. We will have to technically inspect and approve a free combination of individual key features.
  • 7. Krypton® Multi For measuring disinfectants, pH and temperature - optional ORP and 5th measuring input. subjects to alterations - version 07/2015 Accessories hand-held units Radon Des- pH The Radon photometer is used for measuring of Chlorine, Chlorine dioxide, Ozone, Hydrogen peroxide and pH. Accurate and consistent results are obtained quickly. Delivery contents is everything neede to measure Chlorine, Chlorine dioxide and Ozone. The delivery content conains evrything needed for measuring Chlorine, Chlorine dioxide and Ozone. For measurement of Hydrogen peroxide you need a H2O2-addon and for the pH measurement the reagent phenolred. accessories Test Plug DES With the test plug you can check the function and connection of our disinfection measurement - not for Total Chlorine measurement (not TCl). Powered by TCPDF (www.tcpdf.org)