1. AMIT SELADIYA
M: +91 9510099610 | seladiyaamit@yahoo.in
https://in.linkedin.com/amitseladiya
POST APPLIED: ANALYSER MAINTENANCE SPECIALIST.
SUMMARY___________________________________________________________________
I have good technical background of Analyser in Oil & Gas Refinery field. More than 5.5
years’ Experience in Analyser, worked during construction, commissioning, start-up and
Maintenance in many different Oil & Gas Refinery.
HIGHLIGHTS__________________________________________________________________
I am working in also "Reliance Industries Limited" Jamnagar (Gujarat) as a “Analyzer
technician" in refinery , through Invensys (I) Pvt. Ltd-Trident and Enclosed is a copy of my
resume with additional information about my qualifications.
GULF EXPERIENCE___________________________________________________________
UAE ABU-DHABI EXPERIANCE:
“GASCO” refinery in UAE-ABU DHABI through AIMS (Analytical Instruments & Maintenance
systems.
Duration : - 13 Mar 2013 to 10 Nov 2013.
Position : - Analyzer Maintenance Technician.
SAUDI ARABIA :
“PETRO RABIGH” refinery in SAUDI ARABIA through YOKOGAVA.
Duration : - 27 Sep 2015 to Till Date.
Position : - Analyzer Maintenance Specialist.
2. INDIA IN EXPERIENCE
RELIANCE OIL & GAS REFINARY through Trident from Invensys Trident (I) Pvt. Ltd.
Duration: 20 Des 2013 to 22 Sep 2015 and Before 18 Aug 2009 to 28 Feb 2013.
Position: SR Analyzer Maintenance Technician.
EDUCATION__________________________________________________________________
DEPLOMA, INSTRUMENT MECHANICAL.
INDUSTRIAL TRAINING INSTITUTE- Rajkot, Gujarat, India.
SSC-ENGLISH.
GSEB, GANDHINAGAR- Rajkot, Gujarat, India.
Hocasnel Training.
Gujarat State Fertilizers Chemicals.
JOB DESCRIPTION_____________________________________________________________
Analyzers sample conditioning system routine maintenance such as pumps, valves,
actuator, flow mitre membranes filter, aov etc.
SIEMEANS GC in also cline model 50 valve and release diaphragm.
ABB GC in also maintenance liv –replaces slid oaring and Colum switching valve cline and
replace Colum slide.
SRU PLAN IN AMETEK 919 SO2/O2, 900 AIR DEMAND analyzer in also replace cadmium,
magnesium lamp, cleaned cell, mirror and replaced chopper motor, belt and wheel barring
faulty cards and de chock sampling line, analyser also taken in back purging mode and span
and zero gas calibration and auto setup.
AMETEK supplied flue gas O2/CO analyzer in also check and replace faulty cards zirconium
sensor, thermocouple, furnish sample suction side filter, co sensor etc.
POLY PROPYLINE plan in scandal wise cycle gas compressor from PSHS in blow bake work
and cline mott filter.
Preventive Maintenance (Calibration) of Analyzers and Update the calibration sheets.
Maintaining a (FID) Flame Ionization Detector
Corrective maintenance of Analyzers and Replace the faulty sensors, cards.
Daily Inspect Maintenance of On-Line Analyzers and Sampling Systems including trouble
shooting of failures validation and calibration to retain in functional and good operating
3. order for reliable performance. Ion of All Analyzers Sample Point Pressure, Flow, and
Temperature.
Replace the career gas and calibration cylinders for GC and other Analyzers.
Breakdown jobs (Emergency Jobs During Plant Running)
Shutdown and Turnaround activities such as isolation of all sample points, overhaul GC
Analyzers, Replace the filters in primary and secondary sampling boxes, Inspection and
cleaning of sample probes, Check the gas detector alarms, tripping and deluge system
operations.
PM Job, Corrective Maintenance and Troubleshooting of all Analyzer.
Check and Rectify the problem of sampling conditioning boxes such as leak, flow struck up,
replace the micron filters, check values and box temperature problems.
Installation & Commissioning of Sampling Systems of Analyzer Instruments such as Gas
Chromatograph, Moisture and Oxygen Controllers.
Modification of Single and Multi stream selection in sampling system for Gas
Chromatographs and Fault Finding of PLC related loops in Analyzer Shelters.
JOB PROFILE:_______________________________________________________________
Also Pre-commissioning activities such as loops and logics checks and troubleshooting.
Doing the preventive, breakdown and troubleshooting jobs on following analyzers.
ABB supplied vista 2000 series Gas Chromatograph.
SIEMENS Maxum edition 2 Gas Chromatograph.
AMETEK 919 SO2/O2 Stack Analyzer.
AIR DEMAND 900 H2S/S02 Analyzer
.AMETEK 930 Feed Gas (H2S) Analyzer.
AMETEK WDG4 supplied flue gas O2/CO Analyzer.
ROSEMOUNT 4000 O2 Analyzer
FOXBORO, Rosemount, polymetron supplied pH Analyzer.
Maintenance of Sample Condition System.
SICK MAHICK Sox/Nox Analyzer.
AMETEK LAB ANALYZERS MODEL NO 2, 3 and 4 LANCOM analyser.
4. OBJECTIVES__________________________________________________________________
I would like to submit my candidature for the post of Analyzer Technician, for your kind
consideration also working in "Reliance Industries Limited" Jamnagar (Gujarat) as a
“Analyzer Maintenance Specialist " in refinery, through Invensys (I) Pvt. Ltd., and Two
time GULF Retainer through Yokogawa - Enclosed is a copy of my resume with additional
information about my qualifications. Thanks you very much for given your valuable time for
reading and consideration. I look forward to receiving your positive reply.
LANGUAGES__________________________________________________________________
English, Hindi, Guajarati.
SUMMARY___________________________________________________________
A Process Analyzer Professional detailed knowledge and my experience of process and
environmental analytical systems in all aspects.
Experience in Analyzer systems specification, design, installation, commissioning, start‐up,
maintenance and performance monitoring in.
Working Ethylene production, Sulphur recovery plants, Utilities plant and LNG.
My Experience in All parts of analytical system starting from sample probe and up to sample
disposal and going through sample oning, transport, conditioning then the analyzer and
communication with control system.
Range of analyzer/analytical system components manufacturers and system integrators
Knowledge.
Range of analytical methods and techniques knowledge Chromatography, spectroscopy,
electrochemical cells, paramagnetic, TCD, FID, FPD, Paper tape, physical proprieties,
Calorimeters, colorimeters.
Knowles combustible and toxic gas detectors, fire & gas detection systems and Fire
suppression systems.
Aware of most of Analyzer systems Related Standards, Codes and Practices from ISA, IEC,
NFPA, API, ISO, PIP and ASTM.
Specialties: Process Analytical systems specification, design, installation, commissioning,
start‐up and maintenance.
5. SKILLS & TRAINING___________________________________________________________
Analyzers sample conditioning system routine maintenance such as pumps, valves,
actuator, flow miter membranes filter, aov etc.
SIEMEANS GC in also cline model 50 valve and release diaphragm.
ABB GC in also maintenance liv –replaces slid oaring and Colum switching valve cline and
replace Colum slide.
Permit TO work system
HIRA ( Hazard Identification & Risk Assessment)
TRAINING___________________________________________________________
Three day work shop.
Confined Space Attended.
One Day Workshop Safety.
Fire Watch.
Reliance oil & gas industries.
6. PERSONAL DETAILS___________________________________________________________
NAME: AMIT SELADIYA.
ADD.PARMENANT: SRADHA SOC, SR NO 05, BAPASITARAM CHOCK-RAJKOT.
Marital Status: Married.
Citizenship: India.
Date of Birth: 22 Nov. 1990.
Sex: Male.
Mo Number: 0919510099610 (Whats App)
Email: seladiyaamit@yahoo.in
Linked: https://in.linkedin.com/pub/amit-seladiya/62/217/556
PASSPORT DETAILS___________________________________________________________
Passport No. : K 6055177
Date of Issue : 25/07/2012
Date of Expiry : 24/07/2022
Place of Issue : Ahmadabad, Gujarat.