3. Brand Portfolio
Strong dominant brand in the India home market
One of Europe’s most respected commercial and architectural
lighting brands Renowned for its strong design ethos, high
technical performance and aesthetic form
Wide range of contemporary designed fixtures Intended for
lighting medium to large projects (shops, offices, hotels and
restaurants)
4. A full-spectrum provider
of professional electrical solutions worldwide
An Expanding
Global HQ:
Global Leader Noida, India
U$1.4 Billion +
One of the world’s largest lighting
and electrical product companies
13. Vaportite (VP Series) - Fluorescent T5 & T8
FEATURES BENEFITS
Durable fiberglass housing Adaptable to any adverse conditions
Poured in place gasketing Allows enclosure to be sealed from harsh environments
Injection molded diffuser Shatter resistant lens reducing breakage
Corrosive resistant latches Standard on all units
Stainless steel mounting clips For easy installation
Energy Efficient Available with T5 or T8 lamp options
Lightweight Easy to mount
Easy ballast removal Removable gear tray for access
Rubber end plug For utilization of standard die cast liquid or water tight
fittings
IP67 Rated Dust tight rated and temporary immersion in water
NSF Splash Zone Certification Approved for washdown environments
16. Exploded View
Stainless Steel Rubber End Plug
mounting clips
Removable Gear
Polycarbonate tray for ballast
Latch to secure access
lens
Injection molded
diffuser
17. Accessories
Latching Options: Clear Polycarbonate or Stainless Steel. Both options can
easily be made tamper resistant.
Simple Mounting System
Stainless Steel
Reduces installation labor
Latches are
costs
securely held in
No holes drilled through the
place to prevent
housing
loss during
Variable mounting centers
maintenance.
Stainless Steel Mounting Clips rated
UL
Bails
Optional bail provides
convenient means of
suspending the fixture
18. Installation
Insert one side of the Vaportite
housing into the mounting brackets.
Securely attach mounting brackets (2)
mounting surface. The Vaportite enclosure
will engage the mounting brackets at any
point along it’s length, except for where
there are latches. It is recommended that
the dimension between brackets equal
about 70-80% of the enclosure’s length.
19. Vaportite T5 & T8 Fixture
T5 High Output Fluorescent Lamp
T8 & T8HO Fluorescent Lamp
3 Lengths (2’, 4’ and 8’)
2, 3, 4, 6 lamp x 32 T8 watt or 54 T5
watt
Pendant or surface mounted
Supplied with SLI ballast
Universal voltage (120 volt to 277
volt) standard
20. IP Rating System (IP67)
Protection Against Solid Objects Protection Against Liquids
First No. Definition Second No. Definition
0 No protection 0 No protection
1 Protected against solids objects over 50mm 1 Protected against vertically falling drops of
(e.g. accidental touch by hands.) water
2 Protected against solids objects over 12mm 2 Protected against direct sprays up to 15from
(e.g. fingers) the vertical
3 Protected against solids over 2.5mm (e.g. tools 3 Protected against direct sprays up to 60from
and wires) the vertical
4 Protected against solids objects over 1mm (e.g. 4 Protected against sprays form all directions –
tools, wires and small wires limited ingress permitted
5 Protected against dust – limited ingress (no 5 Protected against low pressure jets if water
harmful deposit) from all directions – limited ingress permitted
6 Totally protected against dust (dust tight) 6 Protected against strong jets of water (e.g. for
use on shipdecks – limited ingress permitted
7 Protected against the effects of temporary
immersion between 15cm and 1 m. Duration of
test 30 minutes
8 Protected against long periods of immersion
under pressure.
21. NFS Certification (Splash Zone Rated)
NSF Certification Description of Location/ Use and Commentary Typical Lighting Applications
Non-Food Zone Areas where direct contact with food products during normal Kitchens; food storage dry process areas; damp
operations would not be expected. Equipment is located process areas – no drip possibility
outside the normal washdown area. There is a concern that
the fixture will add contamination to the protected space or
food product (i.e. Cleanability - will the finish withstand
cleaning, chipping paint, deteriorating paints or finishes, lens
impact resistance, lamp glass breakage, etc.
Splash Zone Areas where direct contact with food products during normal Wet or damp process areas; high pressure
operations would not be expected; however , the fixture may purging or decontamination used in the
be situated such that liquids used in the process or cleaning process; area hose washdown
procedures, may splash, spill or otherwise soil – either
intentionally or inadvertently – the surface on the fixture.
There then is the potential for dripping or draining onto other
surfaces or even the process. Since these fixtures are often
used in washdown areas, a Wet Location listing is not
sufficient. Fixtures must be tested to withstand high-pressure
hose washdown. The concerns of Non-Food Zone also apply.
Food Zone Areas where direct contact with food products is normally Category not typically used for lighting
expected and surfaces from which the food may drip, drain, or
splash back onto surfaces normally in contact with food.
Equipment other than lighting fixtures typically require this
certification (i.e. work tables, cutting boards, other direct
contact equipment.
23. CENIT Fluorescent T5 & T8 High Bay Lighting
• Very low profile • Only 2.4’ deep/ Lightweight for easy installation.
• Mounting Options • Can be surface or pendant mounted.
• Pre-wired for multi level switching • Provides for 2 levels of lighting
• Anticorrosive treated steel housing finished with • No sharp edges with anti rust capabilities
electrostatic powder coating after fabrication
• Anodized aluminum reflector designed specifically for • Highly reflective surface yielding very high fixture
each available lamp configuration efficiencies
• Side mounted ballasts • Allows ballast to maintain a lower ambient
temperature
• Havells manufacturing facility builds every fixture • Complete control and adaptability over all aspects
of manufacturing
• Quality Control • Each fixture is lamped and energized in factory
• Energy efficient • Reduces operation costs with a superior quality of
light
• Availability • Most common configurations are in stock
• Several Options • Available with cable mounting kits, wireguards, 6 ft.
cords, emergency ballast, door frames with clear
lens, and occupancy sensors
26. Thermal Impact of Ballast Location
• Overheat test
• Ballast temperature remained below 90°C limit
• Heat emitted by lamps doesn’t rise towards ballasts
Component Temp on Cenit 6x54w
120/
248
100/
Component Temp
212
C/F°
80/
176
60/
140 4x54w Ballast
2x54w Ballast
Lamp (center)
40/
104 20/ 40/ 60/ 80/ 100/ 120/
0 20
68 40
104 60
140 80
176 100
212 120
248
Ambient Temp C/F°
Not recommended for applications with ambient temperature above
35°C (95°F) due to lamp output reduction
27. Installation
• Can be surface or pendant mounted
• Hanging kit must be attached to at least two points on the ceiling
28. Labels on Fixture Body & Cable Kit
• UL required labels and hanging cable kit installation
Stop sleeve on all four
hanging kit cables.
Must pass through this
hole and slide inward.
Surface mount holes.
33. CENIT T5 High Bay Retrofit
Advantages
High efficiency (energy savings and photometricaly efficient).
High CRI, instant restart, and double circuit for energy saving.
Less weight on structures, less heat emission.
Return on Investment (ROI) advantage.
6 Cenit 4x54w T5HO
1,182 watts/21 FC avg.
5 MH 400w
2,485 watts/19FC avg.
5 Cenit 6x54w T5HO
1,550 watts/30FC avg.
Top view of warehouse. Illumination simulation by
Marketing’s Projects Dept.
34. CENIT T5 High Bay Retrofit
Comparison of luminous maintenance & energy savings for a
6 Lamp Fixture
Replacement Costs
(Replace 1–400W MH HID with
1-6 lamp T5HO High Bay
Thousands of emitted lumens
30 fixture)
Cenit 6x54W T5HO 310W $185 installed & lamped
165 watts/fixture of energy
20 savings
Metal Halide 400W 475W
Over 50% increase in lighting
levels
10 Return on Investment
0 5 10 15 20
(ROI) = 20 months
Life in thousands of hours