Contenu connexe Similaire à Clean Patch (20) Clean Patch1. CleanPatch – Product Presentation
Henleys Medical Supply (2014)
First-in-class medical surface repair for hospital
beds and stretchers that restores damaged
mattresses to an intact and hygienic state.
CE Marked Class 1 medical device
2. Barbara Potter, RN
• ICU Manager, 25 years hospital experience
“Mattresses on patient beds are often
damaged, I also know that it is impossible to
properly clean a surface that was not intact,
and yet it was impractical to replace a mattress
each time a small tear appeared”
ripped mattress pathogens
2014 © Surface Medical Inc. 2
Inspired by a Nurse
3. 2014 © Surface Medical Inc. 3
How Big of a Problem is It?
Multi-phase research study in a leading Hospital
conducted by the Ward of the 21st Century, a third
party clinical research organization
Surveyed 20% of mattresses in circulation:
213 patient beds across 33 units
Results
101 mattresses, or 47% had damage (rips, tears, cracks)
30 damaged mattresses were randomly swabbed:
o 20/30 (65%) tested positive for at least 1 organism
o 2/30 (6%) tested positive for Clostridium difficile
o 1/30 (3%) tested positive for VRE
?
5. 2014 © Surface Medical Inc. 5
What we see…
Lifting Tape + Sticky Mess
6. Damaged Mattresses cause Infections!
MRSA
VRE
Acinetobacter
Other
Pseudomonas
Reference: Adapted from Creamer and Humphreys(2008)
Journal of Hospital Infections 69.8-23
• Multiple studies have
demonstrated that:
Hospital mattresses harbor
dangerous pathogens like
MRSA and C.difficile
Multiple outbreaks have
been traced back to
contaminated, damaged
mattresses
Mattress intervention, such
as improved cleaning
and/or returning
mattresses to an intact
state, have been shown to
terminate outbreaks
2014 © Surface Medical Inc. 6
7. The Challenge
To address this issue, we spoke to Healthcare
Stakeholders in all departments (Infection Control,
Facilities, Housekeeping) and the product had to;
Hold up to repetitive cleaning by disinfectants
Not collect bacteria on the edge
Be simple to apply
Be cost-effective
Last in a real hospital setting
72014 © Surface Medical Inc.
8. 8
Introducing… CleanPatch™
3.5 x 3.5 inch Medical Surface Repair Patch
First-in-class medical surface repair for hospital
beds and stretchers that restores damaged
mattresses to an intact and hygienic state.
Designed with Healthcare stakeholders to be
applied in seconds
Safe and Simple
Extends the life of mattresses and stretchers
reducing direct and indirect costs
Cost Savings
Independently tested by a third-party clinical
organization in a real hospital setting
Clinically Tested
2014 © Surface Medical Inc.
9. CleanPatch Clinical Assessment
CleanPatch - Clinical Assessment
Primary Study Objectives
1) What is the incidence and severity of microbial growth on the hospital
mattress and CleanPatch before and after terminal cleaning? Is there any
difference?
2) How does CleanPatch perform in a clinical setting over the duration of the
study?
9
Project Collaborators: Dr. Thomas Louie (UCalgary, AHS), Craig Pearce (AHS), Linda Ward (UCalgary),
Jill de Grood (UCalgary), Holly Wong (UCalgary), Irene Ma (AHS, UCalgary)
2014 © Surface Medical Inc.
10. CleanPatch Clinical Assessment
Study Methods
• CleanPatch was applied to 60 mattresses (1 on
top and 1 on side)
• Testing took place between October 2012 and
January 2013
• 12 Microbial swabs were taken per sample
collection, 720 microbial swabs were cultured.
Mattress
Location
Before Cleaning After Cleaning
Top
CleanPatch Surface
CleanPatch Edge
Mattress Surface
CleanPatch Surface
CleanPatch Edge
Mattress Surface
Side
CleanPatch Surface
CleanPatch Edge
Mattress Surface
CleanPatch Surface
CleanPatch Edge
Mattress Surface
TOP
SIDE
102014 © Surface Medical Inc.
11. Primary Study Questions
• Is there any difference between microbial growth between the hospital mattress and
CleanPatch on the Mattress Top Site?
Study Results
• No significant difference in severity of microbial growth between the hospital mattress
and CleanPatch edge or surface, before and after terminal cleaning
• Reduction in pathogenic growth after terminal cleaning on all areas tested
Mattress Location
TOP SITE
Pathogenic Growth
Before Terminal Cleaning
(Mean)
Pathogenic Growth
After Terminal Cleaning
(Mean)
Mattress (n=60) 1.18 0.27
CleanPatch Edge (n=60) 0.83 0.23
CleanPatch Surface (n=60) 1.10 0.13
P-value vs mattress No Significant Difference No Significant Difference
Summary Results - Mattress Top
112014 © Surface Medical Inc.
12. • 72 CleanPatch applied in October 2012 on mattresses were assessed 1 year
later to determine patch viability and any signs of damage
• 72/72 or 100% looked the same as the day they were applied, CleanPatch
continues to perform well in a hospital environment on mattresses!
Study – 1 Year Follow-up
122014 © Surface Medical Inc.
13. The Clinical Study on CleanPatch met its Primary Objectives,
Peer-reviewed publication coming soon!
• CleanPatch does not harbor any more (or less) organisms
than the hospital mattress, and is comparable in
cleanability
• CleanPatch performed well in a clinical setting
Study - Conclusions
132014 © Surface Medical Inc.
14. Test Protocol Conclusion
180 Degree Peel Test
Accelerated Aging
ASTM D3330 modified
PSTC-9
CleanPatch is stable for at least 2 years under accelerated
aging conditions
Uniaxial Fatigue test Custom designed facility
CleanPatch passed test that included compression,
rotation, urine treatment and cleaning on a ripped
mattress (simulate patient on hospital mattress)
Hospital Disinfectants
testing
Custom designed
CleanPatch was stable when exposed to hospital
disinfectants, including Alcohol, Bleach, Quaterniums and
Hydrogen Peroxide (also proven by disinfectant comp)
Laboratory testing performed at a GLP certified facility
CleanPatch – Durability Testing
142014 © Surface Medical Inc.
15. Mattress (cover + foam)
9.5’’ X 9.5’’ X 3’’
CleanPatch (3.5’’ X 3.5’’)
Mattress Cover Linen
Stainless Steel PlateStainless Steel Plate
1’’ indent
12 to 60 cycles
per hour
90 Degree
Rotation. 45
Degree/sec
A Cut in Mattress (1’’)
Dome Compression
Platen
Uniaxial Fatigue Test - Set-Up
152014 © Surface Medical Inc.
16. Test Condition Conditions
No. Compression 2,880
No. Rotation 2,880
Urine Treatment 16
Cleaning 16
Results
No Change, Passed
Water Leak Test*
Compression = 50% mattress depression
Rotation = (90O
CW and CCWW from Zero at 45O
per sec).
Urine = Artificial Urine. 10ml/treatment.
Cleaning= Hospital Grade Quaternary Ammonium (516ppm). 10ml/treatment.
*Water Leak Test – NHS (UK) developed method, 10ml of water dispensed on surface + pressure
BEFORE
AFTER
Uniaxial Fatigue Test – Results
16
CleanPatch is impermeable, fluid resistant
2014 © Surface Medical Inc.
17. CleanPatch was designed as a preventative maintenance tool for early signs
of damage on hospital beds, stretchers and other surfaces.
Catch the Damage Early!
Characteristic of Damage site ideally suited for CleanPatch:
Less than 2 inches
On the surface or sides
Polyurethane or Vinyl surface (not Nylon or coated covers)
CleanPatch – Safe & Simple
17
EXAMPLES OF DAMAGE
MORE CLEANPATCH
SIZES COMING SOON!
Exam tables, Wheelchairs, Commodes, Chairs may also be possible!
2014 © Surface Medical Inc.
18. Biocompatible: medical grade, latex-free and non-cytotoxic
Easy to Apply: designed in collaboration with Healthcare Stakeholders, can be
applied successfully with gloves (peel and stick).
CleanPatch – Safe & Simple
18
Application video at www.cleanpatch.us
2014 © Surface Medical Inc.
19. For every 100 mattresses fixed, CleanPatch could save >20,000£
* Contact us to develop a specific economic model for your site *
100 damaged hospital mattresses
Cost Savings Example
19
Without CleanPatch
Option Quantity Price
per Unit
New Mattress 100 300 £
TOTAL 30,000£
With CleanPatch
Option Quantity Price
per Unit
New Mattress 30 300 £
CleanPatch 70 9-10 £
TOTAL 9,700£
2014 © Surface Medical Inc.
20. Testimonial
• Over 70 healthcare facilities in North America are purchasing
CleanPatch in the last few months!
"Many studies have shown that healthcare equipment (e.g. mattresses, positioning
pillows, stretchers, wheelchairs, high walkers) that are shared between
patients/residents/clients with rips and tears have resulted in disposal as they
cannot be cleaned nor disinfected properly. We hope to save some money by
using CleanPatch to repair this communal equipment and also provide a safe
environment for our patients. Our facility has been using CleanPatch for the
past eight months and the feedback from our end users is positive,
specifically the product's easy application and durability. We have been
using CleanPatch on our stretchers located in the busy Emergency Department
and it has been able to withstand multiple cleaning and disinfection“
Manager, Infection Prevention and Control in Canada
1000+ bed facility in Toronto, Ontario
Infection Control and User references available upon request
2014 © Surface Medical Inc.
21. Met the Challenge!
After over 2 years of development and testing,
CleanPatch addresses the issue of damaged
mattresses and stretchers;
Cleanable by hospital disinfectants
Does not collect bacteria on the edge
Simple to apply, Peel and Stick
Cost-savings possible
Last in a real hospital setting for 1+ year
212014 © Surface Medical Inc.
22. Thank You
Manufacturer Contact
Tony Abboud
Surface Medical
tony@surfacemedical.ca
403-589-7642
22
www.cleanpatch.ca
Clinical whitepapers, instructions and more information can be found at:
UK Distributor Contact
Henleys Medical Supply
www.henleysmed.com
2014 © Surface Medical Inc.