FHA INSPECTION CHECK LIST
                                    (Prepared for use with FHA/HUD Handbook 4150.2 )
                                             Cliff Odom, RAA Birmingham, AL



VC-1 Location Hazards And Nuisances

                                                                                              Inspection Check List
                                                                                              Yes             No


a.   Subsidence/Sink holes ……………………………………………………… ______                                                   ______

b.   Operating oil or gas wells within 300 feet of existing construction………… ______                       ______
     (Includes gasoline stations within 300 feet of home; however, it would not necessarily
     render the property unacceptable.)

c.   Operating oil or gas wells with 75 feet of new construction………………... ______                           ______

d.   Abandoned oil or gas wells within 10 feet of new/existing………………… ______                               ______

e.   Readily observable evidence of slush pits ………………………………….. ______                                      ______

f.   Excessive noise or hazard from heavy traffic area………………………….. ______                                  ______

g.   New/proposed construction in airport clear zone…………………………… ______                                     ______

h.   High-pressure gas or petroleum lines within engineering
     10 feet or property…………………………………………………………… ______                                                     ______

i.   Overhead high voltage transmission lines within engineering
     (Designed) fall distance……………………………………………………… ______                                                  ______
      (Low voltage power lines may not pass directly over the primary living
       unit , including pools, on the property being insured by HUD)

j. Excessive hazard from smoke, fumes, offensive noises or odors…………….. ______                              ______

k. New/proposed construction in Special Flood Hazard Areas ………………… ______                                  ______

 l. Stationary storage tanks with more than 1000 gallons of flammable or
    explosive material…………………………………………………………… ______                                                        ______


PROPERTY CONSIDERATIONS:

VC-2 Soil Contamination

a. On-site septic system shows readily observable evidence of system failure… ______                        ______
     (Visually inspect septic system and its surrounding area)

b. Surface evidence of an Underground Storage Tank (UST)…………………. ______                                     ______

c. Proximity to dumps, landfills, industrial sites or hazardous materials……… ______                        ______

d.   Presence of pools of liquid, pits, ponds, lagoons, stressed vegetation,
     Stained soils or pavement, drums or odors…………………………………. ______                                         ______
Inspection Check List
                                                                                                 Yes                  No


VC-3 Grading and Drainage

a. Grading does not provide positive drainage from structure………………….                            ______            ______
       (Proper drainage includes gutters and downspouts or appropriate
        grading or landscaping to divert the flow of water away from the
        foundation)

b. Standing Water proximate to structure……………………………………...                                       ______            ______
      (Note any evidence of standing water near the house that indicates improper
      grading. Look for ponding of water in the yard that may enter the foundation)




VC-4 Well, Individual Water Supply and Septic

a. Property lacks connection to public water………………………………….                                      ______            ______
      (Lender will require water testing for “yes” response. – Determine whether
       connection to a public system is feasible).

      If a dug well serves the property – mark “YES)
      A well must be a minimum of 50 feet from a septic tank, 100 feet from the septic
      Tanks drainfield and a minimum of 10 feet from any property line.
      NOTE: If the property is served by dug wells, springs, lakes, cisterns or rivers
      It is INELIGIBLE.

b. Property lacks connection to public/community sewer system…………….                             ______            ______
       (Note the sewage connection – Public/community or septic)
      Determine whether connection to a public system is feasible.
      If connection is feasible, hookup is MANDATORY. Report to the Lender
      Where the sewer line is located, distance from house and feasibility.

      NOTE: If house is vacant - require septic tank service and inspection.

VC-5 Wood Destroying Insects

a.     Structure and accessory buildings are ground level and/or wood is
       Touching ground………………………………………………………….                                                   ______            ______
       (If the structure is ground level or if the structure is wood and touches the ground,
       a termite inspection is required)
       For condominiums, termite inspections are required for first floor units only.

       (Inspection of the subject property include mud tunnels running from the ground up
       and the side of the house, swarms around wood structures and small piles of wings
       around windows. Look for excessive dampness or large areas where the vegetation
       is dead)

b.     The house and/or other structures within the legal boundaries of the
       Property show obvious evidence of active termite infestation…………….                       _______       _______
       (Inspect all buildings/structures located on the subject site)




`



    Cliff Odom, RAA, Birmingham,AL                                                             Page 2    of   8   Pages
Inspection Check List
                                                                                                           Yes      No

VC-6 Private Road Access and Maintenance

a. Property inaccessible by foot or vehicle………………………………………….                                            ______     _______
     (All roads must have vehicular and pedestrian access)

b. Property accessible only by private road or drive………………………………..                                      ______      ______
     REAC FAQ Note: The title search should reveal recorded easements. However, it is the DE
     Underwriter's responsibility to determine if the title policy shows sufficient evidence of a
     Permanent recorded easement.

c. Property is not provided with an all-weather surface (gravel is acceptable). ……                      ______      ______
     FHA Note. FHA defines all-weather surface as a road surface over which emergency
     Vehicles can pass in all types of weather. Provide a detailed description of the roads
      Condition.



VC-7 Structural Conditions

Floor Support Systems.
a. Significant Cracks………………………………………………………………..                                                         ______     ______
     (Examine the flooring/joists for any signs of water leakage or damage, holes, large cracks in
     Concrete slabs, leakage and readily observable evidence of rodent or termite infestation/
     Damage, temporary supports or jacks or piers).

b. Evidence of water/leakage or damage…………………………………………..                                               _______      ______

c.   Rodent infestation………………………………………………………………                                                         ______      ______

Framing/Walls/Ceiling
d. Significant Cracks……………………………………………………………….                                                          ______      ______

e. Visible holes in exposed areas that could effect structure……………………….                                 ______      ______

f. Significant water damage……………………………………………………….                                                       ______     ______

Attic
g. Evidence of holes……………………………………………………………….                                                          ______      ______

h. Support structure not intact or damaged………………………………………..                                            ______      ______

i. Significant water damage visible from interior…………………………………                                         ______      ______

j. No ventilation by vent, fan or window………………………………………….                                              ______      ______

     REAC FAQ Note: The attic must be examined whether access is by pull-down stairway
     Or scuttle. At a minimum head and shoulders entry. However, size and accessibility
     Dictates the level of entry.


     Enter the attic and observe the interior roofing for insulation. Deficient materials, leaks or
     Readily observable evidence of significant water damage, structural problems, previous fire
     Damage exposed or frayed wiring and adequate ventilation by vent, fan or windows.

     NOTE ON INSULATION: Make every effort to determine if insulation is present and the type.
     Enter the R factor or show depth and location. This is required on the URAR under insulation.


 Cliff Odom, RAA Birmingham, AL                                                                        Page 3 of 8 Pages
Inspection Check List
VC-8 Foundation                                                                                             Yes         No
Foundation/Basement
a. Inadequate access………………………………………………………………..                                                            ______      ______
     (Examine the foundation/basement for inadequate access).

b. Evidence of significant water damage………………………………………….                                                 ______       ______
     (Examine the basement and crawl space for water damage)

c.    Significant cracks or erosion in exposed areas that could effect structural
      Soundness……………………………………………………………………..                                                               ______      ______
      (Examine the foundation for cracks, erosion and items, which could effect structural
       Soundness).


Crawl Space
d. Inadequate access……………………………………………………………….                                                             ______      ______
     (Examine the crawl space for inadequate access, distance from floor joists to ground,
      Insulation, ventilation and any other structural problem).

e. Space inadequate for maintenance and repair…………………………………..                                             ______      ______

f. Support beams not intact………………………………………………………..                                                       ______       ______

g.    Excessive dampness or ponding of water………………………………………                                               ______      ______
     REAC FAQ Note: The minimum distance is 18 inches from the bottom of the joists. The
     Appraiser will enter the crawl space (at a minimum entry of the head and shoulders) to
     Observe conditions. The appraiser will examine the crawl space for inadequacies.

      a.   There must be adequate access to the crawl space.
      b.   The floor joists must be sufficiently above ground level to provide access.
      c.   The crawl space must be clear of all debris and trash and must be properly vented.
      d.   The crawl space must not b excessively damp and must not have any water ponding.
      e.   If dampness is noted, a vapor barrier is required.

VC-9 Roofing

a. Does not cover entire house……………………………………………………                                                       ______      ______
     (Note if the roof covers the entire home, if the roof has been repaired, or patched
      Substantially, if material used on the roof was suitable for the subject property)

b. Evidence of deterioration of roofing materials………………………………...                                         ______      ______
     (Look for evidence of shingles curling up and breaking off).
     NOTE: An excellent tool for inspecting the roof is a pair of binoculars when observing the
     Roof from the ground.

c. Roof life is less than two years…………………………………………………                                                   ______       ______
     (HUD requires that the roof have at least 2 years remaining life) The condition must clearly
      state whether the roof is to be repaired or re-roofed. FHA will accept a maximum of 3
      layers of existing roofing. If more than 2 layers of existing roofing, and repair is necessary,
      then all old roofing must be removed as part of the re-roofing.

d. Holes……………………………………………………………………………                                                                    ______       ______

e. Signs of leakage observable from the ground…………………………………..                                             ______      ______
     (Observe ceilings when inside the house. A stained or darkened ceiling inside the home is
      an indication that the roof is leaking. When inspecting the attic, look for leaking roof, and
      be observant around chimney flashing, pipe flashing and where guttering is backing up water).

f. Flat Roof…………………………………………………………………………                                                                 ______      ______
    (All flat roofs require inspection)
Cliff Odom, RAA, Birmingham, AL                                                                           Page 4 of 8 Pages
Inspection Check List
                                                                                                      Yes         No

VC-10 Mechanical Systems

The Appraiser must examine ALL mechanical, plumbing, and electrical systems in the subject
Property to ensure that they are in proper working order. This examination entails turning on
The applicable systems and observing their performance.

Furnace/Heating System
a. Unit does not turn "On"………………………………………………………                                                   ______      ______

b. Warm air is not emitted……………………………………………………….                                                  ______      ______

c. Unusual or irregular smell is emitted…………………………………………                                          ______       ______

d. Smoke or irregular smell is emitted ………………………………………….                                          ______       ______

e. Unit shuts down prior to reaching desired temperature……………………….                                ______       ______

f. Significant holes or deterioration on the unit(s)………………………………                                  ______       ______
      (Determine if there is an installed heat or cool-air source in each room by using the
       system's normal operating controls).

Air Conditioning (central)
g. Unit does not turn "On"………………………………………………………                                                   ______       ______

h. Cold air is not emitted………………………………………………………..                                                 ______      ______

i.    Irregular noises are heard……………………………………………………..                                             ______      ______

j.    Smoke or irregular smell is emitted…………………………………………..                                       ______       ______

k. Unit shuts down prior to reaching desired temperature………………………                                 ______       ______

l.    Significant holes or deterioration on the unit(s)………………………………                               ______       ______

Electrical System
m. Electrical switches do not turn "on" or "off"…………………………………                                     ______      ______

n. Outlets do not function (check representative sample)……………………….                                ______       ______

o. Presence of sparks or smoke from outlet(s)………………………………….                                       ______      ______

p. Exposed wiring visible in living areas……………………………………….                                         ______      ______

q. Frayed wiring………………………………………………………………...                                                       ______      ______
       REAC FAQ Note: For multiple identical components such as windows and electrical
       Outlets, one such component per room. For multiple identical exterior components,
       One such component on each side of the building.

       (Examine the electrical box to ensure that there are circuit breakers with no visible
        frayed wiring or exposed wires in living areas and that there is adequate amperage
        for the appliances present in the property).

       (If the appliances present at the time of the inspection do not appear to be reasonable
        (undersized), determine if there is adequate amperage to run "standard" appliances,
        as per municipal code. (Require an electrical inspection by a licensed electrician).

     Cliff Odom, RAA, Birmingham, AL                                                             Page 5 of 8 Pages
Inspection Check List
                                                                                                  Yes          No

Plumbing System
Toilet
r. Toilets do not function……………………………………………………….                                                ______       ______
     (Observe how quickly the water flushes from the toilet - if slow, check septic tank)

s. Presence of leak(s)…………………………………………………………..                                                  ______       ______
     (Flush toilets and turn on ALL faucets to determine that the plumbing is intact).
     (Check immediate flooring around toilet - look for weakness in floor when applying
      weight directly to the floor).

Leaks
t. Structural damage under fixtures………………………………………….                                             ______      ______
     (Inspect plumbing under kitchen and bathroom sinks/lavatory)

u. Puddles present……………………………………………………………                                                        ______      ______

Sewer System
v. Observable surface evidence of malfunction……………………………..                                       ______      ______
        (Check to see if toilet flush quickly and properly).

Sinks
w. Basin or pipes leak……………………………………………………….                                                     ______      ______

x.      Water does not run……………………………………………………….                                                 ______      ______

Water
y. Significant drop or limitation in pressure……………………………….                                       ______      ______

z. No hot water………………………………………………………………                                                          ______      ______
        (Turn on hot water to ensure that the hot water heater is operating appropriately).
        (Turn on several cold water faucets in the house to check water pressure and flow).




Cliff Odom, RAA, Birmingham, AL



                                                                                                 Page 6 of 8 Pages
Inspection Check List
                                                                                                             Yes        No

VC-11 Other Health and Safety Deficiencies
(Provide a description of yes responses on Page 4 of VC Sheet)

a. Multiple Broken windows………………………………………………………                                                            ______      ______
     REAC FAQ Note: ALL broken windows should be repaired or replaced, as necessary.
     (even if there is only one broken window).

b. Broken or missing exterior stairs……………………………………………….                                                    ______      ______
     (Look for broken or missing steps on stairs and steps to porch and decks - if broken or
     missing make a requirement for repair or replacement of the missing steps).

c. Broken or missing exterior doors………………………………………………                                                      ______      ______

d. Inadequate/blocked entrances or exits………………………………………….                                                  ______      ______
     NOTE: All exterior doors should be operated to determine if they would open and close)

e. Steps without handrails…………………………………………………………                                                           ______      ______
     REAC FAQ Note: When is a handrail necessary? "Usually three or more risers. However,
     If situation poses a safety issue for the occupants, a condition requirement should be made
     Regardless of the number of risers.

f.   The mechanical garage door does not reverse or stop when meeting reasonable
     resistance during closing………………………………………………………..                                                      ______      ______

g.    Please identify location of all health and/or safety deficiencies, and note others
      Not included in this or any other VC on the comment page. ………………….                                   ______     ______

      NOTE: Other health and safety items.

      a.   Bedroom Egress: Occupants must be able to get outside the home if there is a fire. If
           An enclosed patio (solid walls) covers the bedroom window, it is possible that the
           Bedroom won't qualify as a habitable bedroom.

      b.   All water heaters must have a non-adjustable temperature and pressure-relief valve.
           If the water heater is in the garage, it must comply with local building codes.

      c.   All non-conventional heating systems - space heaters and others - must comply with
           Local jurisdictional guidelines. Heating must be adequate for healthful and comfortable
           Living conditions.

      d.   The appraiser must operate a representative number of windows, interior doors, and all
           Exterior and garage doors, as well as verify that the electric garage door operator will
           Reverse or stop when met with resistance during closing.



VC-12 Lead Based Paint Hazard
For any home built prior to 1978, check for evidence of defective paints surfaces, including: peeling,
Scaling or chipping pant. Both exterior and interior surfaces must be inspected.

Provide a description of yes responses on Page 4:

a. Evidence on interior……………………………………………………………..                                                           ______      ______

b. Evidence on exterior…………………………………………………………….                                      ______                            ______
   (Inspect the interior and exterior surfaces - walls, stairs, deck porch, railing,
    windows and doors - for defective (chipping, flaking or peeling). Exterior
     surfaces include those surfaces on fences, detached garages, storage sheds
    and other outbuildings and appurtenant structures.

Cliff Odom, RAA, Birmingham, AL                                                                    Page 7 of 8      Pages
Inspection Check List
                                                                                                       Yes        No

VC-13 Condominiums and Planned Unit Developments (PUD)

a. This project is not on FHA's approval list……………………………………….                                         ______     ______

b. The property does not meet owner-occupancy standards……………………….                                     ______     ______

c. This property does not meet completion standards………………………………                                       ______      ______

NOTES FOR CONDOMINIUM AND PUD DEVELOPMENTS:

    a.   Verify that the CONDO/PUD approval number exists. (The Lender must supply the approval
         Number on the appraisal). If the number is not supplied by lender mark the item "YES" and
         Condition the appraisal on obtaining approval of the condominium or PUD.

    b.   If the project is not approved mark "YES" in the VC and condition the appraisal on this
         Information.

    c.   The project must be at least 51% owner-occupied.




Description of Responses and Related Comments


VC#        Section                    Comments

_____       _____          ___________________________________________________________

_____       _____           ___________________________________________________________

_____        _____           __________________________________________________________

_____        _____            __________________________________________________________

_____        _____            __________________________________________________________

_____        _____            __________________________________________________________

_____        _____            __________________________________________________________

_____        _____            __________________________________________________________

_____        _____             _________________________________________________________




This document was prepared by Cliff Odom, RAA, Cliff Odom Appraisal Service's, Inc
872 Ivawood Road, Birmingham, AL 35210 Telephone: (205) 951-0398



                                                                                                   Page 8 of 8 Pages

Contenu connexe

Tendances

One Step Ahead of Cheaters -- Instrumenting Android Emulators
One Step Ahead of Cheaters -- Instrumenting Android EmulatorsOne Step Ahead of Cheaters -- Instrumenting Android Emulators
One Step Ahead of Cheaters -- Instrumenting Android Emulators
Priyanka Aash
 

Tendances (10)

One Step Ahead of Cheaters -- Instrumenting Android Emulators
One Step Ahead of Cheaters -- Instrumenting Android EmulatorsOne Step Ahead of Cheaters -- Instrumenting Android Emulators
One Step Ahead of Cheaters -- Instrumenting Android Emulators
 
Experience on porting HIGHMEM and KASAN to RISC-V at COSCUP 2020
Experience on porting HIGHMEM and KASAN to RISC-V at COSCUP 2020Experience on porting HIGHMEM and KASAN to RISC-V at COSCUP 2020
Experience on porting HIGHMEM and KASAN to RISC-V at COSCUP 2020
 
Design and Concepts of Android Graphics
Design and Concepts of Android GraphicsDesign and Concepts of Android Graphics
Design and Concepts of Android Graphics
 
淺談探索 Linux 系統設計之道
淺談探索 Linux 系統設計之道 淺談探索 Linux 系統設計之道
淺談探索 Linux 系統設計之道
 
Introduction to Direct 3D 12 by Ivan Nevraev
Introduction to Direct 3D 12 by Ivan NevraevIntroduction to Direct 3D 12 by Ivan Nevraev
Introduction to Direct 3D 12 by Ivan Nevraev
 
ARM Polyglot Shellcode - HITB2019AMS
ARM Polyglot Shellcode - HITB2019AMSARM Polyglot Shellcode - HITB2019AMS
ARM Polyglot Shellcode - HITB2019AMS
 
Getting started with RISC-V verification what's next after compliance testing
Getting started with RISC-V verification what's next after compliance testingGetting started with RISC-V verification what's next after compliance testing
Getting started with RISC-V verification what's next after compliance testing
 
Android local sockets in native code
Android local sockets in native code Android local sockets in native code
Android local sockets in native code
 
Android Storage - Vold
Android Storage - VoldAndroid Storage - Vold
Android Storage - Vold
 
A Journey into Hexagon: Dissecting Qualcomm Basebands
A Journey into Hexagon: Dissecting Qualcomm BasebandsA Journey into Hexagon: Dissecting Qualcomm Basebands
A Journey into Hexagon: Dissecting Qualcomm Basebands
 

En vedette

50727481 checklist-for-site-works
50727481 checklist-for-site-works50727481 checklist-for-site-works
50727481 checklist-for-site-works
imaduddin91
 
Contractor camp inspection check list rev 9 12 16.00hr
Contractor camp inspection check list rev 9 12 16.00hrContractor camp inspection check list rev 9 12 16.00hr
Contractor camp inspection check list rev 9 12 16.00hr
anshse2
 
Health, Safety and Environmental Management Plan
Health, Safety and Environmental Management PlanHealth, Safety and Environmental Management Plan
Health, Safety and Environmental Management Plan
Flevy.com Best Practices
 
Health and safety plan generic
Health and safety plan genericHealth and safety plan generic
Health and safety plan generic
firstpick
 

En vedette (10)

FHA Home Inspection Flags
FHA Home Inspection FlagsFHA Home Inspection Flags
FHA Home Inspection Flags
 
FHA Appraisal and Inspection Issues
FHA Appraisal and Inspection IssuesFHA Appraisal and Inspection Issues
FHA Appraisal and Inspection Issues
 
7 Things You Must Know About 203K Requirement And Guidelines
7 Things You Must Know About 203K Requirement And Guidelines7 Things You Must Know About 203K Requirement And Guidelines
7 Things You Must Know About 203K Requirement And Guidelines
 
Departmental inspection-checklist
Departmental inspection-checklistDepartmental inspection-checklist
Departmental inspection-checklist
 
Flat Roof Inspection Checklist
Flat Roof Inspection ChecklistFlat Roof Inspection Checklist
Flat Roof Inspection Checklist
 
50727481 checklist-for-site-works
50727481 checklist-for-site-works50727481 checklist-for-site-works
50727481 checklist-for-site-works
 
Contractor camp inspection check list rev 9 12 16.00hr
Contractor camp inspection check list rev 9 12 16.00hrContractor camp inspection check list rev 9 12 16.00hr
Contractor camp inspection check list rev 9 12 16.00hr
 
Health, Safety and Environmental Management Plan
Health, Safety and Environmental Management PlanHealth, Safety and Environmental Management Plan
Health, Safety and Environmental Management Plan
 
Health and safety plan generic
Health and safety plan genericHealth and safety plan generic
Health and safety plan generic
 
How to Create a Slideshare Account
How to Create a Slideshare AccountHow to Create a Slideshare Account
How to Create a Slideshare Account
 

Plus de Dean Wegner of Guardian Mortgage, Arizona 602-432-6388

Plus de Dean Wegner of Guardian Mortgage, Arizona 602-432-6388 (20)

Todays 3 Percent Down Mortgage Options 2019
Todays 3 Percent Down Mortgage Options 2019Todays 3 Percent Down Mortgage Options 2019
Todays 3 Percent Down Mortgage Options 2019
 
Freddie Mac HomeOneSM More flexibility
Freddie Mac HomeOneSM More flexibilityFreddie Mac HomeOneSM More flexibility
Freddie Mac HomeOneSM More flexibility
 
Want 2 VA loans at same time? Guaranty calculation Examples VA rtgage
Want 2 VA loans at same time? Guaranty calculation Examples VA rtgageWant 2 VA loans at same time? Guaranty calculation Examples VA rtgage
Want 2 VA loans at same time? Guaranty calculation Examples VA rtgage
 
1% New Builder credit with flier Dean Wegner
1% New Builder credit with flier Dean Wegner1% New Builder credit with flier Dean Wegner
1% New Builder credit with flier Dean Wegner
 
New Mortgage Loan Application 2018
New Mortgage Loan Application 2018New Mortgage Loan Application 2018
New Mortgage Loan Application 2018
 
Unison Buying a Home ebook
Unison Buying a Home ebookUnison Buying a Home ebook
Unison Buying a Home ebook
 
UNISON Program, how it works!
UNISON Program, how it works!UNISON Program, how it works!
UNISON Program, how it works!
 
LLPA Matrix
LLPA MatrixLLPA Matrix
LLPA Matrix
 
VA National Guard Benefit Summary to Buy a Home
VA National Guard Benefit Summary to Buy a HomeVA National Guard Benefit Summary to Buy a Home
VA National Guard Benefit Summary to Buy a Home
 
FHA Appraisal Overview
FHA Appraisal OverviewFHA Appraisal Overview
FHA Appraisal Overview
 
Tips for a Smooth Mortgage Transaction!
Tips for a Smooth Mortgage Transaction!Tips for a Smooth Mortgage Transaction!
Tips for a Smooth Mortgage Transaction!
 
Mortgage Payment Options at HomeStreet Home Loans
Mortgage Payment Options at HomeStreet Home LoansMortgage Payment Options at HomeStreet Home Loans
Mortgage Payment Options at HomeStreet Home Loans
 
HomeStreet has Awesome Loans!!
HomeStreet has Awesome Loans!!HomeStreet has Awesome Loans!!
HomeStreet has Awesome Loans!!
 
Documents Needed Checklist with Dean Wegner
Documents Needed Checklist with Dean WegnerDocuments Needed Checklist with Dean Wegner
Documents Needed Checklist with Dean Wegner
 
Dean Wegner is at HomeStreet Home Loans Now!
Dean Wegner is at HomeStreet Home Loans Now!Dean Wegner is at HomeStreet Home Loans Now!
Dean Wegner is at HomeStreet Home Loans Now!
 
About HomeStreet Home Loans
About HomeStreet Home LoansAbout HomeStreet Home Loans
About HomeStreet Home Loans
 
10 steps to home ownership Dean Wegner
10 steps to home ownership   Dean Wegner10 steps to home ownership   Dean Wegner
10 steps to home ownership Dean Wegner
 
Pathway to Purchase
Pathway to PurchasePathway to Purchase
Pathway to Purchase
 
Arizona Diamondbacks
Arizona DiamondbacksArizona Diamondbacks
Arizona Diamondbacks
 
The price is right! how to accurately value a home feb 18th
The price is right!  how to accurately value a home feb 18thThe price is right!  how to accurately value a home feb 18th
The price is right! how to accurately value a home feb 18th
 

Dernier

9990771857 Call Girls in Dwarka Sector 08 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 08 Delhi (Call Girls) Delhi9990771857 Call Girls in Dwarka Sector 08 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 08 Delhi (Call Girls) Delhi
delhimodel235
 
BPTP THE AMAARIO For The Royals Of Tomorrow in Sector 37D Gurgaon Dwarka Expr...
BPTP THE AMAARIO For The Royals Of Tomorrow in Sector 37D Gurgaon Dwarka Expr...BPTP THE AMAARIO For The Royals Of Tomorrow in Sector 37D Gurgaon Dwarka Expr...
BPTP THE AMAARIO For The Royals Of Tomorrow in Sector 37D Gurgaon Dwarka Expr...
ApartmentWala1
 
9990771857 Call Girls Dwarka Sector 8 Delhi (Call Girls ) Delhi
9990771857 Call Girls  Dwarka Sector 8 Delhi (Call Girls ) Delhi9990771857 Call Girls  Dwarka Sector 8 Delhi (Call Girls ) Delhi
9990771857 Call Girls Dwarka Sector 8 Delhi (Call Girls ) Delhi
delhimodel235
 
Call Girls In Vasant Vihar Delhi 💯Call Us 🔝8264348440🔝
Call Girls In Vasant Vihar Delhi 💯Call Us 🔝8264348440🔝Call Girls In Vasant Vihar Delhi 💯Call Us 🔝8264348440🔝
Call Girls In Vasant Vihar Delhi 💯Call Us 🔝8264348440🔝
soniya singh
 
9990771857 Call Girls Dwarka Sector 9 Delhi (Call Girls ) Delhi
9990771857 Call Girls Dwarka Sector 9 Delhi (Call Girls ) Delhi9990771857 Call Girls Dwarka Sector 9 Delhi (Call Girls ) Delhi
9990771857 Call Girls Dwarka Sector 9 Delhi (Call Girls ) Delhi
delhimodel235
 
9990771857 Call Girls in Dwarka Sector 2 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 2 Delhi (Call Girls) Delhi9990771857 Call Girls in Dwarka Sector 2 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 2 Delhi (Call Girls) Delhi
delhimodel235
 
Best Deal Virtual Space in Satya The Hive Tata Zudio 750 Sqft 1.89 Cr All inc...
Best Deal Virtual Space in Satya The Hive Tata Zudio 750 Sqft 1.89 Cr All inc...Best Deal Virtual Space in Satya The Hive Tata Zudio 750 Sqft 1.89 Cr All inc...
Best Deal Virtual Space in Satya The Hive Tata Zudio 750 Sqft 1.89 Cr All inc...
ApartmentWala1
 
Call Girls in Karkardooma Delhi +91 84487779280}Woman Seeking Man in Delhi NCR
Call Girls in Karkardooma Delhi +91 84487779280}Woman Seeking Man in Delhi NCRCall Girls in Karkardooma Delhi +91 84487779280}Woman Seeking Man in Delhi NCR
Call Girls in Karkardooma Delhi +91 84487779280}Woman Seeking Man in Delhi NCR
asmaqueen5
 
Call Girls In Krishna Nagar Delhi (Escort)↫8447779280↬@SHOT 1500- NIGHT 5500→...
Call Girls In Krishna Nagar Delhi (Escort)↫8447779280↬@SHOT 1500- NIGHT 5500→...Call Girls In Krishna Nagar Delhi (Escort)↫8447779280↬@SHOT 1500- NIGHT 5500→...
Call Girls In Krishna Nagar Delhi (Escort)↫8447779280↬@SHOT 1500- NIGHT 5500→...
asmaqueen5
 
9990771857 Call Girls in Dwarka Sector 137 Noida (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 137 Noida (Call Girls) Delhi9990771857 Call Girls in Dwarka Sector 137 Noida (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 137 Noida (Call Girls) Delhi
delhimodel235
 

Dernier (20)

Kohinoor Flats In Hinjewadi Phase 2 | Homes Built To Suit Your Needs
Kohinoor Flats In Hinjewadi Phase 2 | Homes Built To Suit Your NeedsKohinoor Flats In Hinjewadi Phase 2 | Homes Built To Suit Your Needs
Kohinoor Flats In Hinjewadi Phase 2 | Homes Built To Suit Your Needs
 
9990771857 Call Girls in Dwarka Sector 08 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 08 Delhi (Call Girls) Delhi9990771857 Call Girls in Dwarka Sector 08 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 08 Delhi (Call Girls) Delhi
 
Kolte Patil Kharadi Pune E Brochure.pdf
Kolte Patil Kharadi Pune E  Brochure.pdfKolte Patil Kharadi Pune E  Brochure.pdf
Kolte Patil Kharadi Pune E Brochure.pdf
 
BPTP THE AMAARIO For The Royals Of Tomorrow in Sector 37D Gurgaon Dwarka Expr...
BPTP THE AMAARIO For The Royals Of Tomorrow in Sector 37D Gurgaon Dwarka Expr...BPTP THE AMAARIO For The Royals Of Tomorrow in Sector 37D Gurgaon Dwarka Expr...
BPTP THE AMAARIO For The Royals Of Tomorrow in Sector 37D Gurgaon Dwarka Expr...
 
Purva Soukhyam in Guduvancheri Chennai.pdf
Purva Soukhyam in Guduvancheri Chennai.pdfPurva Soukhyam in Guduvancheri Chennai.pdf
Purva Soukhyam in Guduvancheri Chennai.pdf
 
9990771857 Call Girls Dwarka Sector 8 Delhi (Call Girls ) Delhi
9990771857 Call Girls  Dwarka Sector 8 Delhi (Call Girls ) Delhi9990771857 Call Girls  Dwarka Sector 8 Delhi (Call Girls ) Delhi
9990771857 Call Girls Dwarka Sector 8 Delhi (Call Girls ) Delhi
 
Call Girls In Vasant Vihar Delhi 💯Call Us 🔝8264348440🔝
Call Girls In Vasant Vihar Delhi 💯Call Us 🔝8264348440🔝Call Girls In Vasant Vihar Delhi 💯Call Us 🔝8264348440🔝
Call Girls In Vasant Vihar Delhi 💯Call Us 🔝8264348440🔝
 
The Gale at Godrej Park World Hinjewadi Pune Brochure.pdf
The Gale at Godrej Park World Hinjewadi Pune Brochure.pdfThe Gale at Godrej Park World Hinjewadi Pune Brochure.pdf
The Gale at Godrej Park World Hinjewadi Pune Brochure.pdf
 
9990771857 Call Girls Dwarka Sector 9 Delhi (Call Girls ) Delhi
9990771857 Call Girls Dwarka Sector 9 Delhi (Call Girls ) Delhi9990771857 Call Girls Dwarka Sector 9 Delhi (Call Girls ) Delhi
9990771857 Call Girls Dwarka Sector 9 Delhi (Call Girls ) Delhi
 
9990771857 Call Girls in Dwarka Sector 2 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 2 Delhi (Call Girls) Delhi9990771857 Call Girls in Dwarka Sector 2 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 2 Delhi (Call Girls) Delhi
 
Enjoy Night ≽ 8448380779 ≼ Call Girls In Huda City Centre (Gurgaon)
Enjoy Night ≽ 8448380779 ≼ Call Girls In Huda City Centre (Gurgaon)Enjoy Night ≽ 8448380779 ≼ Call Girls In Huda City Centre (Gurgaon)
Enjoy Night ≽ 8448380779 ≼ Call Girls In Huda City Centre (Gurgaon)
 
Best Deal Virtual Space in Satya The Hive Tata Zudio 750 Sqft 1.89 Cr All inc...
Best Deal Virtual Space in Satya The Hive Tata Zudio 750 Sqft 1.89 Cr All inc...Best Deal Virtual Space in Satya The Hive Tata Zudio 750 Sqft 1.89 Cr All inc...
Best Deal Virtual Space in Satya The Hive Tata Zudio 750 Sqft 1.89 Cr All inc...
 
2k Shot Call girls Karol Bagh Delhi 9205541914
2k Shot Call girls Karol Bagh Delhi 92055419142k Shot Call girls Karol Bagh Delhi 9205541914
2k Shot Call girls Karol Bagh Delhi 9205541914
 
Call Girls in Karkardooma Delhi +91 84487779280}Woman Seeking Man in Delhi NCR
Call Girls in Karkardooma Delhi +91 84487779280}Woman Seeking Man in Delhi NCRCall Girls in Karkardooma Delhi +91 84487779280}Woman Seeking Man in Delhi NCR
Call Girls in Karkardooma Delhi +91 84487779280}Woman Seeking Man in Delhi NCR
 
BDSM⚡Call Girls in Sector 57 Noida Escorts >༒8448380779 Escort Service
BDSM⚡Call Girls in Sector 57 Noida Escorts >༒8448380779 Escort ServiceBDSM⚡Call Girls in Sector 57 Noida Escorts >༒8448380779 Escort Service
BDSM⚡Call Girls in Sector 57 Noida Escorts >༒8448380779 Escort Service
 
TENANT SCREENING REPORT SERVICES​ How Tenant Screening Reports Work
TENANT SCREENING REPORT SERVICES​ How Tenant Screening Reports WorkTENANT SCREENING REPORT SERVICES​ How Tenant Screening Reports Work
TENANT SCREENING REPORT SERVICES​ How Tenant Screening Reports Work
 
2k Shots ≽ 9205541914 ≼ Call Girls In Sainik Farm (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Sainik Farm (Delhi)2k Shots ≽ 9205541914 ≼ Call Girls In Sainik Farm (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Sainik Farm (Delhi)
 
Call Girls In Krishna Nagar Delhi (Escort)↫8447779280↬@SHOT 1500- NIGHT 5500→...
Call Girls In Krishna Nagar Delhi (Escort)↫8447779280↬@SHOT 1500- NIGHT 5500→...Call Girls In Krishna Nagar Delhi (Escort)↫8447779280↬@SHOT 1500- NIGHT 5500→...
Call Girls In Krishna Nagar Delhi (Escort)↫8447779280↬@SHOT 1500- NIGHT 5500→...
 
9990771857 Call Girls in Dwarka Sector 137 Noida (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 137 Noida (Call Girls) Delhi9990771857 Call Girls in Dwarka Sector 137 Noida (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 137 Noida (Call Girls) Delhi
 
Premium Villa Projects in Sarjapur Road Bengaluru
Premium Villa Projects in Sarjapur Road BengaluruPremium Villa Projects in Sarjapur Road Bengaluru
Premium Villa Projects in Sarjapur Road Bengaluru
 

FHA INSPECTION CHECK LIST (Prepared for use with FHA/HUD Handbook 4150.2

  • 1. FHA INSPECTION CHECK LIST (Prepared for use with FHA/HUD Handbook 4150.2 ) Cliff Odom, RAA Birmingham, AL VC-1 Location Hazards And Nuisances Inspection Check List Yes No a. Subsidence/Sink holes ……………………………………………………… ______ ______ b. Operating oil or gas wells within 300 feet of existing construction………… ______ ______ (Includes gasoline stations within 300 feet of home; however, it would not necessarily render the property unacceptable.) c. Operating oil or gas wells with 75 feet of new construction………………... ______ ______ d. Abandoned oil or gas wells within 10 feet of new/existing………………… ______ ______ e. Readily observable evidence of slush pits ………………………………….. ______ ______ f. Excessive noise or hazard from heavy traffic area………………………….. ______ ______ g. New/proposed construction in airport clear zone…………………………… ______ ______ h. High-pressure gas or petroleum lines within engineering 10 feet or property…………………………………………………………… ______ ______ i. Overhead high voltage transmission lines within engineering (Designed) fall distance……………………………………………………… ______ ______ (Low voltage power lines may not pass directly over the primary living unit , including pools, on the property being insured by HUD) j. Excessive hazard from smoke, fumes, offensive noises or odors…………….. ______ ______ k. New/proposed construction in Special Flood Hazard Areas ………………… ______ ______ l. Stationary storage tanks with more than 1000 gallons of flammable or explosive material…………………………………………………………… ______ ______ PROPERTY CONSIDERATIONS: VC-2 Soil Contamination a. On-site septic system shows readily observable evidence of system failure… ______ ______ (Visually inspect septic system and its surrounding area) b. Surface evidence of an Underground Storage Tank (UST)…………………. ______ ______ c. Proximity to dumps, landfills, industrial sites or hazardous materials……… ______ ______ d. Presence of pools of liquid, pits, ponds, lagoons, stressed vegetation, Stained soils or pavement, drums or odors…………………………………. ______ ______
  • 2. Inspection Check List Yes No VC-3 Grading and Drainage a. Grading does not provide positive drainage from structure…………………. ______ ______ (Proper drainage includes gutters and downspouts or appropriate grading or landscaping to divert the flow of water away from the foundation) b. Standing Water proximate to structure……………………………………... ______ ______ (Note any evidence of standing water near the house that indicates improper grading. Look for ponding of water in the yard that may enter the foundation) VC-4 Well, Individual Water Supply and Septic a. Property lacks connection to public water…………………………………. ______ ______ (Lender will require water testing for “yes” response. – Determine whether connection to a public system is feasible). If a dug well serves the property – mark “YES) A well must be a minimum of 50 feet from a septic tank, 100 feet from the septic Tanks drainfield and a minimum of 10 feet from any property line. NOTE: If the property is served by dug wells, springs, lakes, cisterns or rivers It is INELIGIBLE. b. Property lacks connection to public/community sewer system……………. ______ ______ (Note the sewage connection – Public/community or septic) Determine whether connection to a public system is feasible. If connection is feasible, hookup is MANDATORY. Report to the Lender Where the sewer line is located, distance from house and feasibility. NOTE: If house is vacant - require septic tank service and inspection. VC-5 Wood Destroying Insects a. Structure and accessory buildings are ground level and/or wood is Touching ground…………………………………………………………. ______ ______ (If the structure is ground level or if the structure is wood and touches the ground, a termite inspection is required) For condominiums, termite inspections are required for first floor units only. (Inspection of the subject property include mud tunnels running from the ground up and the side of the house, swarms around wood structures and small piles of wings around windows. Look for excessive dampness or large areas where the vegetation is dead) b. The house and/or other structures within the legal boundaries of the Property show obvious evidence of active termite infestation……………. _______ _______ (Inspect all buildings/structures located on the subject site) ` Cliff Odom, RAA, Birmingham,AL Page 2 of 8 Pages
  • 3. Inspection Check List Yes No VC-6 Private Road Access and Maintenance a. Property inaccessible by foot or vehicle…………………………………………. ______ _______ (All roads must have vehicular and pedestrian access) b. Property accessible only by private road or drive……………………………….. ______ ______ REAC FAQ Note: The title search should reveal recorded easements. However, it is the DE Underwriter's responsibility to determine if the title policy shows sufficient evidence of a Permanent recorded easement. c. Property is not provided with an all-weather surface (gravel is acceptable). …… ______ ______ FHA Note. FHA defines all-weather surface as a road surface over which emergency Vehicles can pass in all types of weather. Provide a detailed description of the roads Condition. VC-7 Structural Conditions Floor Support Systems. a. Significant Cracks……………………………………………………………….. ______ ______ (Examine the flooring/joists for any signs of water leakage or damage, holes, large cracks in Concrete slabs, leakage and readily observable evidence of rodent or termite infestation/ Damage, temporary supports or jacks or piers). b. Evidence of water/leakage or damage………………………………………….. _______ ______ c. Rodent infestation……………………………………………………………… ______ ______ Framing/Walls/Ceiling d. Significant Cracks………………………………………………………………. ______ ______ e. Visible holes in exposed areas that could effect structure………………………. ______ ______ f. Significant water damage………………………………………………………. ______ ______ Attic g. Evidence of holes………………………………………………………………. ______ ______ h. Support structure not intact or damaged……………………………………….. ______ ______ i. Significant water damage visible from interior………………………………… ______ ______ j. No ventilation by vent, fan or window…………………………………………. ______ ______ REAC FAQ Note: The attic must be examined whether access is by pull-down stairway Or scuttle. At a minimum head and shoulders entry. However, size and accessibility Dictates the level of entry. Enter the attic and observe the interior roofing for insulation. Deficient materials, leaks or Readily observable evidence of significant water damage, structural problems, previous fire Damage exposed or frayed wiring and adequate ventilation by vent, fan or windows. NOTE ON INSULATION: Make every effort to determine if insulation is present and the type. Enter the R factor or show depth and location. This is required on the URAR under insulation. Cliff Odom, RAA Birmingham, AL Page 3 of 8 Pages
  • 4. Inspection Check List VC-8 Foundation Yes No Foundation/Basement a. Inadequate access……………………………………………………………….. ______ ______ (Examine the foundation/basement for inadequate access). b. Evidence of significant water damage…………………………………………. ______ ______ (Examine the basement and crawl space for water damage) c. Significant cracks or erosion in exposed areas that could effect structural Soundness…………………………………………………………………….. ______ ______ (Examine the foundation for cracks, erosion and items, which could effect structural Soundness). Crawl Space d. Inadequate access………………………………………………………………. ______ ______ (Examine the crawl space for inadequate access, distance from floor joists to ground, Insulation, ventilation and any other structural problem). e. Space inadequate for maintenance and repair………………………………….. ______ ______ f. Support beams not intact……………………………………………………….. ______ ______ g. Excessive dampness or ponding of water……………………………………… ______ ______ REAC FAQ Note: The minimum distance is 18 inches from the bottom of the joists. The Appraiser will enter the crawl space (at a minimum entry of the head and shoulders) to Observe conditions. The appraiser will examine the crawl space for inadequacies. a. There must be adequate access to the crawl space. b. The floor joists must be sufficiently above ground level to provide access. c. The crawl space must be clear of all debris and trash and must be properly vented. d. The crawl space must not b excessively damp and must not have any water ponding. e. If dampness is noted, a vapor barrier is required. VC-9 Roofing a. Does not cover entire house…………………………………………………… ______ ______ (Note if the roof covers the entire home, if the roof has been repaired, or patched Substantially, if material used on the roof was suitable for the subject property) b. Evidence of deterioration of roofing materials………………………………... ______ ______ (Look for evidence of shingles curling up and breaking off). NOTE: An excellent tool for inspecting the roof is a pair of binoculars when observing the Roof from the ground. c. Roof life is less than two years………………………………………………… ______ ______ (HUD requires that the roof have at least 2 years remaining life) The condition must clearly state whether the roof is to be repaired or re-roofed. FHA will accept a maximum of 3 layers of existing roofing. If more than 2 layers of existing roofing, and repair is necessary, then all old roofing must be removed as part of the re-roofing. d. Holes…………………………………………………………………………… ______ ______ e. Signs of leakage observable from the ground………………………………….. ______ ______ (Observe ceilings when inside the house. A stained or darkened ceiling inside the home is an indication that the roof is leaking. When inspecting the attic, look for leaking roof, and be observant around chimney flashing, pipe flashing and where guttering is backing up water). f. Flat Roof………………………………………………………………………… ______ ______ (All flat roofs require inspection) Cliff Odom, RAA, Birmingham, AL Page 4 of 8 Pages
  • 5. Inspection Check List Yes No VC-10 Mechanical Systems The Appraiser must examine ALL mechanical, plumbing, and electrical systems in the subject Property to ensure that they are in proper working order. This examination entails turning on The applicable systems and observing their performance. Furnace/Heating System a. Unit does not turn "On"……………………………………………………… ______ ______ b. Warm air is not emitted………………………………………………………. ______ ______ c. Unusual or irregular smell is emitted………………………………………… ______ ______ d. Smoke or irregular smell is emitted …………………………………………. ______ ______ e. Unit shuts down prior to reaching desired temperature………………………. ______ ______ f. Significant holes or deterioration on the unit(s)……………………………… ______ ______ (Determine if there is an installed heat or cool-air source in each room by using the system's normal operating controls). Air Conditioning (central) g. Unit does not turn "On"……………………………………………………… ______ ______ h. Cold air is not emitted……………………………………………………….. ______ ______ i. Irregular noises are heard…………………………………………………….. ______ ______ j. Smoke or irregular smell is emitted………………………………………….. ______ ______ k. Unit shuts down prior to reaching desired temperature……………………… ______ ______ l. Significant holes or deterioration on the unit(s)……………………………… ______ ______ Electrical System m. Electrical switches do not turn "on" or "off"………………………………… ______ ______ n. Outlets do not function (check representative sample)………………………. ______ ______ o. Presence of sparks or smoke from outlet(s)…………………………………. ______ ______ p. Exposed wiring visible in living areas………………………………………. ______ ______ q. Frayed wiring………………………………………………………………... ______ ______ REAC FAQ Note: For multiple identical components such as windows and electrical Outlets, one such component per room. For multiple identical exterior components, One such component on each side of the building. (Examine the electrical box to ensure that there are circuit breakers with no visible frayed wiring or exposed wires in living areas and that there is adequate amperage for the appliances present in the property). (If the appliances present at the time of the inspection do not appear to be reasonable (undersized), determine if there is adequate amperage to run "standard" appliances, as per municipal code. (Require an electrical inspection by a licensed electrician). Cliff Odom, RAA, Birmingham, AL Page 5 of 8 Pages
  • 6. Inspection Check List Yes No Plumbing System Toilet r. Toilets do not function………………………………………………………. ______ ______ (Observe how quickly the water flushes from the toilet - if slow, check septic tank) s. Presence of leak(s)………………………………………………………….. ______ ______ (Flush toilets and turn on ALL faucets to determine that the plumbing is intact). (Check immediate flooring around toilet - look for weakness in floor when applying weight directly to the floor). Leaks t. Structural damage under fixtures…………………………………………. ______ ______ (Inspect plumbing under kitchen and bathroom sinks/lavatory) u. Puddles present…………………………………………………………… ______ ______ Sewer System v. Observable surface evidence of malfunction…………………………….. ______ ______ (Check to see if toilet flush quickly and properly). Sinks w. Basin or pipes leak………………………………………………………. ______ ______ x. Water does not run………………………………………………………. ______ ______ Water y. Significant drop or limitation in pressure………………………………. ______ ______ z. No hot water……………………………………………………………… ______ ______ (Turn on hot water to ensure that the hot water heater is operating appropriately). (Turn on several cold water faucets in the house to check water pressure and flow). Cliff Odom, RAA, Birmingham, AL Page 6 of 8 Pages
  • 7. Inspection Check List Yes No VC-11 Other Health and Safety Deficiencies (Provide a description of yes responses on Page 4 of VC Sheet) a. Multiple Broken windows……………………………………………………… ______ ______ REAC FAQ Note: ALL broken windows should be repaired or replaced, as necessary. (even if there is only one broken window). b. Broken or missing exterior stairs………………………………………………. ______ ______ (Look for broken or missing steps on stairs and steps to porch and decks - if broken or missing make a requirement for repair or replacement of the missing steps). c. Broken or missing exterior doors……………………………………………… ______ ______ d. Inadequate/blocked entrances or exits…………………………………………. ______ ______ NOTE: All exterior doors should be operated to determine if they would open and close) e. Steps without handrails………………………………………………………… ______ ______ REAC FAQ Note: When is a handrail necessary? "Usually three or more risers. However, If situation poses a safety issue for the occupants, a condition requirement should be made Regardless of the number of risers. f. The mechanical garage door does not reverse or stop when meeting reasonable resistance during closing……………………………………………………….. ______ ______ g. Please identify location of all health and/or safety deficiencies, and note others Not included in this or any other VC on the comment page. …………………. ______ ______ NOTE: Other health and safety items. a. Bedroom Egress: Occupants must be able to get outside the home if there is a fire. If An enclosed patio (solid walls) covers the bedroom window, it is possible that the Bedroom won't qualify as a habitable bedroom. b. All water heaters must have a non-adjustable temperature and pressure-relief valve. If the water heater is in the garage, it must comply with local building codes. c. All non-conventional heating systems - space heaters and others - must comply with Local jurisdictional guidelines. Heating must be adequate for healthful and comfortable Living conditions. d. The appraiser must operate a representative number of windows, interior doors, and all Exterior and garage doors, as well as verify that the electric garage door operator will Reverse or stop when met with resistance during closing. VC-12 Lead Based Paint Hazard For any home built prior to 1978, check for evidence of defective paints surfaces, including: peeling, Scaling or chipping pant. Both exterior and interior surfaces must be inspected. Provide a description of yes responses on Page 4: a. Evidence on interior…………………………………………………………….. ______ ______ b. Evidence on exterior……………………………………………………………. ______ ______ (Inspect the interior and exterior surfaces - walls, stairs, deck porch, railing, windows and doors - for defective (chipping, flaking or peeling). Exterior surfaces include those surfaces on fences, detached garages, storage sheds and other outbuildings and appurtenant structures. Cliff Odom, RAA, Birmingham, AL Page 7 of 8 Pages
  • 8. Inspection Check List Yes No VC-13 Condominiums and Planned Unit Developments (PUD) a. This project is not on FHA's approval list………………………………………. ______ ______ b. The property does not meet owner-occupancy standards………………………. ______ ______ c. This property does not meet completion standards……………………………… ______ ______ NOTES FOR CONDOMINIUM AND PUD DEVELOPMENTS: a. Verify that the CONDO/PUD approval number exists. (The Lender must supply the approval Number on the appraisal). If the number is not supplied by lender mark the item "YES" and Condition the appraisal on obtaining approval of the condominium or PUD. b. If the project is not approved mark "YES" in the VC and condition the appraisal on this Information. c. The project must be at least 51% owner-occupied. Description of Responses and Related Comments VC# Section Comments _____ _____ ___________________________________________________________ _____ _____ ___________________________________________________________ _____ _____ __________________________________________________________ _____ _____ __________________________________________________________ _____ _____ __________________________________________________________ _____ _____ __________________________________________________________ _____ _____ __________________________________________________________ _____ _____ __________________________________________________________ _____ _____ _________________________________________________________ This document was prepared by Cliff Odom, RAA, Cliff Odom Appraisal Service's, Inc 872 Ivawood Road, Birmingham, AL 35210 Telephone: (205) 951-0398 Page 8 of 8 Pages