1. Floor Plans Ground Floor Plan
First Floor Plan
Roof Level Plan
Elevations &
Sections
External Elevations
Courtyard Elevations
Section Views
Section Views
TGD
Compliance
TGD M Compliance
TGD B Compliance Ground Floor
TGD B Compliance First Floor
General Arrangement Drawings
Drawing Legend
Details Sheets Wall Section A-A
Wall Section B-B
Window Details
Main Entrance Threshold Details
Intermediate Wall Details
Wall Details
Roof Light Connection & Ventilation Details
Energy Analysis/BREEAM Energy Analysis
Ground Floor Level BREEAM Compliance
Natural Ventilation
Sustainability Specific Drawings
GATPGF102
GATPFF103
GATPRL104
GATPEE105
GATPCE106
GATPSV107
GATPSV108
GATPTGDMC109
GATPTGDBC110
GATPTGDBC111
GATPWS112
GATPWS113
GATPWD114
GATPTD115
GATPIWD116
GATPWD117
GATPRLD118
GATPEA120
BCTPGF121
BCTPNV122
Axonometric Views GATPAV119
General Arrangement Drawings
Scale
LECTURER
Drawn by
Date
Project number
Institute of Technology Carlow
BSc. (Hons) in Architectural Technology
Year 4 2013-2014
1 : 1
Cover Sheet
2
Studio Thesis: School Building of
the Future
02-May-2014
Edel Fox
Noel Dunne, Sujana Sudhir
& Dan O' Sullivan
TPCS101
Edel Fox
C00146668
Architectural Technology
Year 4
Kingswood School Tallaght
Thesis Project
School Buildings Of The
Future
Noel Dunne, Sujana Sudhir
& Dan O' Sullivan
Specification:
Primary Structure – 300mm x 300mm reinforced
precast concrete columns to be placed at grid line
intersections as shown in the plan. 450mm x 500mm
edge beams and 600mm x 500mm inverted T beams
to be used to structurally support the flooring slabs.
Reinforcements to be in accordance with structural
engineers specifications and where possible to be
recycled steel.
Structural Foundations – Each primary structure
300mm x 300mm square precast concrete column to
be connected back to its own individual precast
concrete pocket foundation. Each precast concrete
column will vary in depth depending on the slope of
the ground beneath. The rest of the building is to be
structurally supported below by a reinforced raft
foundation. Steel reinforcements to be in
accordance with engineers specifications. The raft
foundation is to be wrapped around the precast
concrete columns.
Ground Floor Build Up – 50mm sand blinding to be
placed onto the ground, a layer of DPM is to be
lapped and sealed and placed above the sand
blinding, 100mm Expanded Polystyrene (EPS) rigid
foam insulation to create a continuous barrier which
will eliminate cold bridges around the foundation.
Then a structural raft foundation is to be put in place
with reinforcements to be in accordance with
engineer’s specifications, and the cast in situ
concrete to be in accordance with BS EN 1992-1-
2:2004. Followed with a layer of 100mm structural
screed topping, finished with either a layer of 60mm
terrazzo floor finish or a vinyl floor finish depending
on the room use.
Intermediate Floor Build Up – The main structure
of the floor is made up of 200mm precast concrete
hollowcore flooring slabs in accordance with BS EN
1992-1-2:2004. This is followed by a layer of 100mm
structural screed which casts the rebars into place
tying the hollowcore flooring slabs back to the
precast concrete edge beams. The floor is finished
with either a layer of 60mm terrazzo floor finish or a
vinyl floor finish depending on the room use.
Roof Build Up – The main structure of the roof is
made up of 200mm precast concrete hollowcore
slabs in accordance with BS EN 1992-1-2:2004. This
is followed by a layer of 100mm structural screed
which casts the rebars into place tying the hollowcore
flooring slabs back to the precast concrete edge
beams. This is followed by a vapour control layer
applied directly to the structural screed. Followed by
a layer of 150mm Expanded Polystyrene (EPS) rigid
foam insulation, to eliminate cold bridges along the
roof deck. Applied directly to the insulation is a
waterproofing membrane to stop water penetration.
The roof is finished with a layer of single ply EDPM
waterproofing membrane.
External Wall Build Up – From Exterior: 8mm
external render finish applied directly onto mesh
reinforcement, mesh reinforcement to apply render
finish to, 12mm cement particle board fixed @ 600mm
c/c, 200mm x 100mm steel U-channels fixed back to
the precast concrete wall panels @ 600mm c/c put in
place to support the cement particle board, with
200mm expanded polystyrene (EPS) rigid foam
insulation in between, finished with 200mm solid wall
precast concrete panels in accordance with BS EN
1992-1-2:2004 with an exposed internal finish.
Internal Wall Build Up – Stud Partition: Double
layer of 12.5mm gyproc board fixed back to 75mm
steel c channels with 75mm mineral wool insulation in
between, finished with a double layer of gyproc board
with a minimum of a 60min Fire Rating.
Blockwork: 200mm Exposed Polished Finish
Blockwork Partition Wall with a minimum of a 60min
Fire Rating.
General Notes:
-All works to comply with current building regulations and code of practice.
-All works must be done to the satisfaction of the building control officer.
-All dimensions in mm unless otherwise noted.
-Drawings must not be scaled, written dimensions must be followed.
-Primary structure precast concrete columns to be placed on the intersection of grid
lines as shown.
- Primary structure precast concrete beams to span along gridlines and to be cast in
place with a precast concrete column above and below.
-External walls not placed along gridlines, walls to be placed to the outer face of the
precast concrete column unless otherwise stated.
-Internal walls of the sports hall to be placed in between the precast concrete columns
as indicated on the plan.
-Primary structure precast concrete columns and beams to be in accordance with BS
EN 1992-1-2:2004.
-Solid wall precast concrete panels to be in accordance with BS EN 1992-1-2:2004.
-Precast concrete for lift shaft and stair shaft to comply with BS EN 1992-1-2:2004.
-Lift and stair shaft to be 60min fire proof including access doors.
-All escape fire doors to be 60min fire rated and fitted with automatic closers.
-Floor finish to be non-slip vinyl flooring and terrazzo flooring.
-Entrance area to have a minimum level landing within 1800mm of entrance door.
Curtain Walling Specification:
Curtain Wall CW 50
-Manufacturer: Reynaers Ltd
-Product reference: Curtain Wall CW 50 Standard
/Curtain Wall CW 50-FP EW 30
/Curtain Wall CW 50-FP EW 60 /Curtain Wall CW
50- HL /Curtain Wall CW 50-RA
-Internal framing member: Extruded aluminium
- Finish: Anodized /Polyester powder coated
- Colour: White
-External cover cap: Extruded aluminium
- Finish: Anodized /Polyester powder coated
- Colour: White
-Windows: Fixed light (CW50-FP) /Glazed in windows
- Configuration: Horizontal pivot /Parallel opener
/Side hung /Tilt and turn /Top hung
-Glazing: Insulating glass units /Single glazed panes
-Glazing system: Dry glazed gasket
Window Specification:
Windows – Aluminium – Clad Timber – Manufacturer - Carlson
-Glass – Double glazing with low E glass – argon filled- thermal
conductivity 1.0 W/m²k
Toughened safety glass for windows installed below
800mm above ground level
-Frame – Internal: Softwood thermal conductivity 0.13 W/m²k in
accordance with ISO 10077-2:2003
External: Recycled aluminium
-Overall U-value of 1.35W/m²k achieving an A rating
-Manufactured to comply with BS 644:2012
-Weather performance must be tested in accordance with BS
6375-1
-Security performance must be tested to BS EN 1627-1630
Door Specification:
Doors – System – Reynaers CS 86 – HI Highly Energy
Efficient
Glass - Double glazing with low E glass – argon filled-
thermal conductivity 1.0 W/m²k
Toughened safety glass for glass panes installed
below 800mm above ground level
Frame – Aluminium inward opening flush door 68mm
Vent – 76mm
U-Value – 1.35W/m²k achieving an A rating
Thermal insulation must be tested in accordance with EN
ISO 10077-2
Acoustic performance must be tested in accordance with
EN ISO 140-3, EN ISO 717-1
Burglar resistance must be tested in accordance with NEN
5096-ENV1627
Solar Shading Specifications:
-Colt shadovoltaic solar shading system
with integrated photovoltaic cells into the
glass louvres
-Manufacturer: Colt
-Carrier system 4
-Metal frame coating in a weatherproof
white paint
-Glass to span in lengths of 1000mm
-Glass to span in widths of 600mm
-Angle of rotation 0-85°
Controls:
-Electronically operated via actuators
-SolTronic controls to be used
Aircool Ventilators Specifications:
-Manufacturer: Passivent
-Frame and external weather lourves:
extruded aluminium, with ABS thermal break
-Insect screen 4mm black polypropylene
-Internal cover grille: extruded aluminium
-Size: 1200mm x 1200mm x 180mm
-White polyester coated
-Class 1 fire rating in accordance with BS 476:
Part 7: 1987
-Weather performance in accordance with BS
EN 13030: 2001
-Air leakage performance in accordance with
BS 6375: Part 1: 1989
-Controls: 24V modulating actuators, control
sensors to be put in place to consider
temperature, CO₂, humidity and wind
2. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
AA
BB
CC
DD
EE
FF
GG
HH
II
JJ
KK
LL
MM
NN
OO
PP
QQ
RR
SS
88 m²
Music/Drama
1
Room Legend
Administrative
Classroom
Health and Fitness
Kitchen
Maintenance
Sports Hall
Storage
Toilets
Travel
Workshop
286 m²
General Purpose/Dining
2
41 m²
Serving Kitchenette
3
5 m²
Store Room
4
11 m²
Store Room
534 m²
Staff Changing Room
6
13 m²
Female Toilets
7
11 m²
Male Toilets
9
5 m²
Corridor
8
19 m²
Stairs
10
71 m²
Learning Support Room
11
51 m²
Classroom One
12
69 m²
Career Guidance Room
13
52 m²
Religion Room
14
17 m²
Guidance Office
15 34 m²
Meditation Room
16
17 m²
Guidance Office
17
17 m²
Chaplin
18
34 m²
Group Room
19
17 m²
First Aid Room
20
51 m²
Classroom Two
21
93 m²
Dress Design Room
22
51 m²
Classroom Three
23
117 m²
Home Economics Room
24
51 m²
Classroom Four
25
51 m²
Classroom Five
26
118 m²
Home Economics Room
27
22 m²
Stairs
28
30 m²
Store Room
29
30 m²
Pastoral Office
30
39 m²
Group Room
31
36 m²
Female Toilets
32
36 m²
Male Toilets
34
35 m²
Female Changing Room
36
34 m²
Male Changing Room
37
68 m²
Gym Store Room
38
5 m²
Data Room
39
15 m²
Staff Changing Room
40
6 m²
Switch Room
41
8 m²
Cleaner Room
42
6 m²
Lift
43
10 m²
Gym Control
44
581 m²
Gym/Sports Hall
45
34 m²
General Office
46
8 m²
Photocopy Room
47
8 m²
Data Room
48
33 m²
Male Toilets
49
36 m²
Female Toilets
50
70 m²
Cloak/Bag Room
51
17 m²
Stairs
52
17 m²
Pastoral Office
53
86 m²
Technical Graphics Room
54
52 m²
Classroom Six
33
207 m²
Library/Media Room
35
139 m²
Engineering Room
55
139 m²
Construction Studies Room
56156 m²
Lecture Room
57
68 m²
Preperation Area
58
51 m²
Classroom Seven
59
139 m²
Technology Room
60
51 m²
Classroom Eight
61
11 m²
Unit Store Room
62
11 m²
Daily Living Skills
63
23 m²
Staff Toilets
64
52 m²
Practical Activity Room
66
78 m²
Class Base One
65
6 m²
Shower
67
6 m²
Shower
68
6 m²
Shower
69
8 m²
Corridor
70
15 m²
Withdrawl Room
71
15 m²
Withdrawl Room
72
6 m²
Corridor
73
72 m²
Class Base Two
74
18 m²
Educational Room
75
18 m²
General Office
76
18 m²
Multi Sensory Room
77
1
FD30
2
FD30
3
FD30
4
FD30
5
FD30
6
FD30
7
FD60
9
FD30
10
FD30
12
FD30
13
FD30
14
FD30
15
FD30
17
FD30
19
FD30
18
FD30
21
FD30
23
FD30
24
FD30
26
FD30
25
FD30
28
FD30
29
FD30
30
FD60
31
FD30
32
FD30
33
FD30
34
FD30
35
FD30
38
FD30
40
FD60
41
FD30
42
FD60
43
FD30
44
FD30
46
FD30
37
FD30
49
FD30
51
FD60
53
FD60
55
FD30
56
FD30
58
FD30
59
FD30
60
FD30
61
FD60
62
FD30
63
FD60
64
FD30
65
FD30
67
FD30
68
FD30
56
FD30
69
FD30
58
FD3072
FD30
71
FD30
74
FD30
73
FD30
76
FD30
77
FD30
78
FD30
79
FD30
80
FD30
81
FD30
82
FD30
83
FD30
84
FD30
85
FD3086
FD30
88
FD30
89
FD30
90
FD30
47
FD60
1374 m²
Main Corridor
78
87
FD30
94
FD30
95
FD30
96
FD30
52
FD30
91
FD60
113
FD30
17 m²
Stairs
79
16 m²
Stairs
80
16 m²
Stairs
81
50
FD60
54
FD60
39
FD30
93
FD60
41 m²
Outdoor Learning
82
97
FD60
98
FD60
99
FD60
25 m²
Caretakers Work Area
83
52 m²
External Storage
84
53 m²
Boiler Room
85
8
FD60
16
FD30
92
FD30
11
FD60
20
FD60
22
FD60
27
FD60
36
FD60 45
FD60
48
FD60
57
FD60
66
FD60
70
FD60
75
FD60
1228101040031010200
1248 1010
405
1010 1128395 1810 395
395 1810 395
11281010263
26310101128
23281010525101023282328101052510102328
140020001400
35010101040
395 1810 395
1128101052510101128
3501010104011281010263
26310101128
200 1810 740 2428 1010 2653 1010 300 1128 1010 5251010 1128
1090 1010 300
3951810395
1128 10105251010 1128
10901010300
1128 1010 1050 10106001010 1393
1128 1010 5251010 1128
347134071326310101128
3951810395
3951810395
1040 1010350
2951810295
3201810320
350 1810 240
1370 2000 1430
240 1810 350
3201810320
11281010 525 10101128
3951810395
300 10101090 1328 1010263
12401010350395181074510101040
35010101040
30010101090
30010101090
395 1810 395
112810105251010112811281010263
112810105251010112826310101128
26310101128
2075 1010 1715
26310101128
2328101052510102328126101038910102265
1148 1010 242
112810102631128101052510101128
1328 1010 525 101011282408 1010 1583
39518103952002000200
820 1810 990 750 400 750 500 750 500 750 300 750 600 750 300 750 600 750 300 750 600 750 300 750 600 750 300 750 600 750 300 750 600 750 300 750 600 750 300 750 600 750 300 750 600 750 300 750 600 750 300 750 600 750 300 750 600 750 300 750 600 750 300 750 600 750 7920800 750 500 750 400 750 500 750 292 758200750
7950750500750400750500750260750180750100575040075050075040075040075040075050075040075056075040075050075040075050075040075044075046075044075046075044075046075044075046075042075040075058075042075042075046075044075046075042075040075058075040075044075046075044075046075042075040075060075040075042075046075044075046075044075040075056075040075044075040075096575024075048475095067502007504537502007508598
1220240024002400240024002400240024002600260024002400240024002400240024002400240024002400570240024002400240024002400240024002400240024002400240024002400240024002400240024002400
102990
795 750 400 750 500 750 400 750200750 400 750 845 1810 720 750 300 750 300 750 1030 750 300 750 300 750 653 750 380 750 600 750 375 750 525 750 300 750 600 750 300 750 600 750 300 750 418 750 250 750 833 750 400 750 500 750 400 750 500 750 400 750 500 750 400 750 500 750 400 750 500 750 400 750 500 750 400 750 380 750 400 750 88 34140 100750 300 750 600 750 300 750 800 750 300 750193750 500 750 1000 750 300 750 600 750 300 750 600 750 300 750 808 60750200750220750 520 750 800
570 2400 2400 2400 2600 2600 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2600 2600 2400 2400 2400 2400 2400 570
107540
10250820750400750500750400750500750400750500750300750770181060075020075010082075040075060075040075050075028875052575030075060075030075060011507505007502887506137504007504007504007507007503007504007503387506637503007506007502887506137504007505007504007505007504007504007504007507007502007507007503007505007504007505007502887506137502887506137502927586007503757504257504007507007503007505007503007506007503007509085207501130
1220240024002400240024002400240024002600260024002400240024002400240024002400240024002400240024002400240024002400240024002400240024002400240024002400240024002400570
95790
23220 6840 938 750 300 750 400 750 625 750 708 750 400 750 700 750 292 758 500 750 920 540 750 540 750 500 750 500 750 500 750 300 750 820
57024002400240024002400260026002400240024002400240024002400240024002400240024002400240024002400240024002400240024002400240024002400240024002400240024002400570 2400 2400 2400 2600 2600 2400
107540
9781010412
11281010 263
1
2
3
4
5
6
7
8
9
10
11
12
13
14 15
16
17
18
19
20
21
1
2
3
4
5
6
7
8
9
10
11
12
13
1415
16
17
18
19
20
21
1
2
3
4
5
6
7
8
9
10
11
12
13
1415
16
17
18
19
20
21
1
2
3
4
5
6
7
8
9
10
11
12
13
1415
16
17
18
19
20
21
1
2
3
4
5
6
7
8
9
10
11
21
20
19
18
17
16
15
14
13
12
1
2
3
4
5
6
7
8
9
10
11
21
20
19
18
17
16
15
14
13
12
Main Entrance
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
200mm Exposed Polished
Finish Blockwork Partition
Wall 60min Fire Rating
125mm Steel Stud Partition
Internal Wall 60min Fire
Rating
300mm Square Primary
Structure Precast Concrete
Column in accordance with
BS En 1992-1-2:2004
200mm Exposed Polished
Finish Blockwork Partition
Wall 60min Fire Rating
125mm Steel Stud Partition
Internal Wall 60min Fire
Rating
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
300mm Square Primary
Structure Precast Concrete
Column in accordance with
BS En 1992-1-2:2004
125mm Steel Stud Partition
Internal Wall 60min Fire
Rating
200mm Exposed Polished
Finish Blockwork Partition
Wall 60min Fire Rating
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
200mm Exposed Polished
Finish Blockwork Partition
Wall 60min Fire Rating
300mm Square Primary
Structure Precast Concrete
Column in accordance with
BS En 1992-1-2:2004
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
200mm Exposed Polished
Finish Blockwork Partition
Wall 60min Fire Rating
300mm Square Primary
Structure Precast Concrete
Column in accordance with
BS En 1992-1-2:2004
200mm Exposed Polished
Finish Blockwork Partition
Wall 60min Fire Rating
125mm Steel Stud Partition
Internal Wall 60min Fire
Rating
300mm Square Primary
Structure Precast Concrete
Column in accordance with
BS En 1992-1-2:2004
125mm Steel Stud Partition
Internal Wall 60min Fire
Rating
200mm Exposed Polished
Finish Blockwork Partition
Wall 60min Fire Rating
300mm Square Primary
Structure Precast Concrete
Column in accordance with
BS En 1992-1-2:2004
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
300mm Square Primary
Structure Precast Concrete
Column in accordance with
BS En 1992-1-2:2004
200mm Exposed Polished
Finish Blockwork Partition
Wall 60min Fire Rating
UP
UP
UP
1
2
UP
UP
UP
Ground Floor Legend
Main Entrance
Fire Exit
Void Openings Above
Wheelchair Access Circle
50mm Reclaimed clay
paver with no sub base
surface treatment
Grass surface treatment
Secondary Entrance
Scale
LECTURER
Drawn by
Date
Project number
Institute of Technology Carlow
BSc. (Hons) in Architectural Technology
Year 4 2013-2014
1 : 200
Ground Floor Level Plan
2
Studio Thesis: School Building of
the Future
02-May-2014
Edel Fox
Noel Dunne, Sujana Sudhir
& Dan O' Sullivan
GATPGF102
1 : 200
Ground Floor Level1
Ground Floor Door Schedule
Level Family and Type Height Width Fire Rating Count
Ground Floor Level Dbl Glass (1): Dbl Glass (1) 2000 FD30 3
Ground Floor Level ExtDbl Flush Fire Escape: 1810 x 2110mm 2110 1810 FD30 4
Ground Floor Level IntDbl (5): 1810 x 2110mm 2110 1810 FD60 25
Ground Floor Level Internal Classroom Doors: 1010 x 2110mm 2110 1010 FD30 43
Ground Floor Level Internal Door Frosted Glass Triple Panel: 1010 x 2110mm 2110 1010 FD30 17
Ground Floor Level Internal Door Frosted Glass: 1010 x 2110mm 2110 1010 FD30 5
Ground Floor Level IntSgl (1): 1010 x 2110mm 2110 1010 FD60 3
Ground Floor Level IntSgl (7): Internal Single FD30 1010 x 2110mm 2110 1010 FD30 2
Grand total: 102
Ground Floor Window Schedule
Level Family and Type Height Width Count
Ground Floor Level Bathroom Window: Bathroom Window 1500 750 42
Ground Floor Level Window A: Window A 1500 750 384
Ground Floor Level Window B: Window B 500 750 274
Ground Floor Level Window C: Window C 500 750 141
Grand total: 841
Ground Floor Room Schedule
No. Name Level Area Department
84 External Storage Ground Floor Level 52 m² Storage
Toilets
7 Female Toilets Ground Floor Level 13 m² Toilets
9 Male Toilets Ground Floor Level 11 m² Toilets
32 Female Toilets Ground Floor Level 36 m² Toilets
34 Male Toilets Ground Floor Level 36 m² Toilets
49 Male Toilets Ground Floor Level 33 m² Toilets
50 Female Toilets Ground Floor Level 36 m² Toilets
64 Staff Toilets Ground Floor Level 23 m² Toilets
Travel
8 Corridor Ground Floor Level 5 m² Travel
10 Stairs Ground Floor Level 19 m² Travel
28 Stairs Ground Floor Level 22 m² Travel
43 Lift Ground Floor Level 6 m² Travel
52 Stairs Ground Floor Level 17 m² Travel
70 Corridor Ground Floor Level 8 m² Travel
73 Corridor Ground Floor Level 6 m² Travel
78 Main Corridor Ground Floor Level 1374 m² Travel
79 Stairs Ground Floor Level 17 m² Travel
80 Stairs Ground Floor Level 16 m² Travel
81 Stairs Ground Floor Level 16 m² Travel
Workshop
22 Dress Design Room Ground Floor Level 93 m² Workshop
24 Home Economics Room Ground Floor Level 117 m² Workshop
27 Home Economics Room Ground Floor Level 118 m² Workshop
54 Technical Graphics Room Ground Floor Level 86 m² Workshop
35 Library/Media Room Ground Floor Level 207 m² Workshop
55 Engineering Room Ground Floor Level 139 m² Workshop
56 Construction Studies Room Ground Floor Level 139 m² Workshop
57 Lecture Room Ground Floor Level 156 m² Workshop
60 Technology Room Ground Floor Level 139 m² Workshop
63 Daily Living Skills Ground Floor Level 11 m² Workshop
66 Practical Activity Room Ground Floor Level 52 m² Workshop
71 Withdrawl Room Ground Floor Level 15 m² Workshop
72 Withdrawl Room Ground Floor Level 15 m² Workshop
77 Multi Sensory Room Ground Floor Level 18 m² Workshop
82 Outdoor Learning Ground Floor Level 41 m² Workshop
Grand total: 85
Ground Floor Room Schedule
No. Name Level Area Department
Administrative
15 Guidance Office Ground Floor Level 17 m² Administrative
17 Guidance Office Ground Floor Level 17 m² Administrative
18 Chaplin Ground Floor Level 17 m² Administrative
30 Pastoral Office Ground Floor Level 30 m² Administrative
46 General Office Ground Floor Level 34 m² Administrative
47 Photocopy Room Ground Floor Level 8 m² Administrative
53 Pastoral Office Ground Floor Level 17 m² Administrative
76 General Office Ground Floor Level 18 m² Administrative
Classroom
1 Music/Drama Ground Floor Level 88 m² Classroom
11 Learning Support Room Ground Floor Level 71 m² Classroom
12 Classroom One Ground Floor Level 51 m² Classroom
13 Career Guidance Room Ground Floor Level 69 m² Classroom
14 Religion Room Ground Floor Level 52 m² Classroom
16 Meditation Room Ground Floor Level 34 m² Classroom
19 Group Room Ground Floor Level 34 m² Classroom
21 Classroom Two Ground Floor Level 51 m² Classroom
23 Classroom Three Ground Floor Level 51 m² Classroom
25 Classroom Four Ground Floor Level 51 m² Classroom
26 Classroom Five Ground Floor Level 51 m² Classroom
31 Group Room Ground Floor Level 39 m² Classroom
33 Classroom Six Ground Floor Level 52 m² Classroom
59 Classroom Seven Ground Floor Level 51 m² Classroom
61 Classroom Eight Ground Floor Level 51 m² Classroom
65 Class Base One Ground Floor Level 78 m² Classroom
74 Class Base Two Ground Floor Level 72 m² Classroom
75 Educational Room Ground Floor Level 18 m² Classroom
Health and Fitness
6 Staff Changing Room Ground Floor Level 34 m² Health and Fitness
20 First Aid Room Ground Floor Level 17 m² Health and Fitness
36 Female Changing Room Ground Floor Level 35 m² Health and Fitness
37 Male Changing Room Ground Floor Level 34 m² Health and Fitness
40 Staff Changing Room Ground Floor Level 15 m² Health and Fitness
67 Shower Ground Floor Level 6 m² Health and Fitness
68 Shower Ground Floor Level 6 m² Health and Fitness
69 Shower Ground Floor Level 6 m² Health and Fitness
Kitchen
2 General Purpose/Dining Ground Floor Level 286 m² Kitchen
3 Serving Kitchenette Ground Floor Level 41 m² Kitchen
Maintenance
39 Data Room Ground Floor Level 5 m² Maintenance
41 Switch Room Ground Floor Level 6 m² Maintenance
42 Cleaner Room Ground Floor Level 8 m² Maintenance
44 Gym Control Ground Floor Level 10 m² Maintenance
48 Data Room Ground Floor Level 8 m² Maintenance
83 Caretakers Work Area Ground Floor Level 25 m² Maintenance
85 Boiler Room Ground Floor Level 53 m² Maintenance
Sports Hall
45 Gym/Sports Hall Ground Floor Level 581 m² Sports Hall
Storage
4 Store Room Ground Floor Level 5 m² Storage
5 Store Room Ground Floor Level 11 m² Storage
29 Store Room Ground Floor Level 30 m² Storage
38 Gym Store Room Ground Floor Level 68 m² Storage
51 Cloak/Bag Room Ground Floor Level 70 m² Storage
58 Preperation Area Ground Floor Level 68 m² Storage
62 Unit Store Room Ground Floor Level 11 m² Storage
*Window Tags Omitted For Clarity On Drawing
General Notes:
-All works to comply with current building
regulations and code of practice.
-All works must be done to the
satisfaction of the building control officer.
-All dimensions in mm unless otherwise
noted.
-Drawings must not be scaled, written
dimensions must be followed.
-Primary structure precast concrete
columns to be placed on the intersection
of grid lines as shown.
- Primary structure precast concrete
beams to span along gridlines and to be
cast in place with a precast concrete
column above and below.
-External walls not placed along
gridlines, walls to be placed to the outer
face of the precast concrete column
unless otherwise stated.
-Internal walls of the sports hall to be
placed in between the precast concrete
columns as indicated on the plan.
-Primary structure precast concrete
columns and beams to be in accordance
with BS EN 1992-1-2:2004.
-Solid wall precast concrete panels to be
in accordance with BS EN 1992-1-
2:2004.
-Precast concrete for lift shaft and stair
shaft to comply with BS EN 1992-1-
2:2004.
-Lift and stair shaft to be 60min fire proof
including access doors.
-All escape fire doors to be 60min fire
rated and fitted with automatic closers.
-Floor finish to be non-slip vinyl flooring
and terrazzo flooring.
-Entrance area to have a minimum level
landing within 1800mm of entrance door.
Specification:
Primary Structure – 300mm x 300mm reinforced
precast concrete columns to be placed at grid line
intersections as shown in the plan. 450mm x 500mm
edge beams and 600mm x 500mm inverted T beams
to be used to structurally support the flooring slabs.
Reinforcements to be in accordance with structural
engineers specifications and where possible to be
recycled steel.
Structural Foundations – Each primary structure
300mm x 300mm square precast concrete column to
be connected back to its own individual precast
concrete pocket foundation. Each precast concrete
column will vary in depth depending on the slope of
the ground beneath. The rest of the building is to be
structurally supported below by a reinforced raft
foundation. Steel reinforcements to be in
accordance with engineers specifications. The raft
foundation is to be wrapped around the precast
concrete columns.
Ground Floor Build Up – 50mm sand blinding to be
placed onto the ground, a layer of DPM is to be
lapped and sealed and placed above the sand
blinding, 100mm Expanded Polystyrene (EPS) rigid
foam insulation to create a continuous barrier which
will eliminate cold bridges around the foundation.
Then a structural raft foundation is to be put in place
with reinforcements to be in accordance with
engineer’s specifications, and the cast in situ
concrete to be in accordance with BS EN 1992-1-
2:2004. Followed with a layer of 100mm structural
screed topping, finished with either a layer of 60mm
terrazzo floor finish or a vinyl floor finish depending
on the room use.
Intermediate Floor Build Up – The main structure
of the floor is made up of 200mm precast concrete
hollowcore flooring slabs in accordance with BS EN
1992-1-2:2004. This is followed by a layer of 100mm
structural screed which casts the rebars into place
tying the hollowcore flooring slabs back to the
precast concrete edge beams. The floor is finished
with either a layer of 60mm terrazzo floor finish or a
vinyl floor finish depending on the room use.
Roof Build Up – The main structure of the roof is
made up of 200mm precast concrete hollowcore
slabs in accordance with BS EN 1992-1-2:2004. This
is followed by a layer of 100mm structural screed
which casts the rebars into place tying the hollowcore
flooring slabs back to the precast concrete edge
beams. This is followed by a vapour control layer
applied directly to the structural screed. Followed by
a layer of 150mm Expanded Polystyrene (EPS) rigid
foam insulation, to eliminate cold bridges along the
roof deck. Applied directly to the insulation is a
waterproofing membrane to stop water penetration.
The roof is finished with a layer of single ply EDPM
waterproofing membrane.
External Wall Build Up – From Exterior: 8mm
external render finish applied directly onto mesh
reinforcement, mesh reinforcement to apply render
finish to, 12mm cement particle board fixed @ 600mm
c/c, 200mm x 100mm steel U-channels fixed back to
the precast concrete wall panels @ 600mm c/c put in
place to support the cement particle board, with
200mm expanded polystyrene (EPS) rigid foam
insulation in between, finished with 200mm solid wall
precast concrete panels in accordance with BS EN
1992-1-2:2004 with an exposed internal finish.
Internal Wall Build Up – Stud Partition: Double
layer of 12.5mm gyproc board fixed back to 75mm
steel c channels with 75mm mineral wool insulation in
between, finished with a double layer of gyproc board
with a minimum of a 60min Fire Rating.
Blockwork: 200mm Exposed Polished Finish
Blockwork Partition Wall with a minimum of a 60min
Fire Rating.
3. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
AA
BB
CC
DD
EE
FF
GG
HH
II
JJ
KK
LL
MM
NN
OO
PP
QQ
RR
SS
28 m²
Store Room
86
20 m²
Pastoral Office
87
4 m²
Corridor
88
87 m²
Science Laboratory
89
56 m²
Science Preperation Room
90
85 m²
Science Laboratory
91
Room Legend
Administrative
Classroom
Health and Fitness
Kitchen
Maintenance
Storage
Toilets
Travel
Workshop
85 m²
Science Laboratory
92
56 m²
Science Preperation Room
93
85 m²
Science Laboratory
94
85 m²
Science Laboratory
95
56 m²
Science Preperation Room
96
85 m²
Business/Computer Room
97
85 m²
Business/Computer Room
98
52 m²
Classroom 26
99
51 m²
Classroom 25
100
51 m²
Classroom 24
101
51 m²
Classroom 23
102
51 m²
Classroom 22
103
51 m²
Classroom 21
104
28 m²
Store Room
105
17 m²
Pastoral Office
106
17 m²
Stairs
107
70 m²
Demonstration Room
10835 m²
Female Toilets
109
32 m²
Male Toilets
110
69 m²
Maths Room
11121 m²
Deputy Principal Office
112
21 m²
Deputy Principal Office
113
21 m²
Principal Office
114
69 m²
Maths Room
115
51 m²
Classroom 20
116
51 m²
Classroom 19
117
51 m²
Classroom 18
118
52 m²
Classroom 17
119
10 m²
Switch Room
121
4 m²
Corridor
121
140 m²
Fitness Suite
122
14 m²
Male Changing Room
123
14 m²
Female Changing Room
124
25 m²
Male Toilets
125
25 m²
Female Toilets
126
21 m²
Project Store
128
21 m²
Pastoral Office
129
15 m²
Stairs
130
87 m²
Design & Communication Graphics
131
51 m²
Classroom 16
132
51 m²
Classroom 15
133
69 m²
Social Studies
134
16 m²
Store Room
135
51 m²
Classroom 14
136
69 m²
Social Studies
137
51 m²
Classroom 13
138
51 m²
Classroom 12
139
51 m²
Classroom 11
140
103 m²
Art Room
141
51 m²
Classroom 10
142
51 m²
Classroom 9
143
105 m²
Art Room
144
19 m²
Stairs
145 11 m²
Male Toilets
146
13 m²
Female Toilets
147
5 m²
Corridor
148 173 m²
Staff Room
149
100
FD60
101
FD30
102
FD30
103
FD30
104
FD60
106
FD30
107
FD30
109
FD30
110
FD30
112
FD30
113
FD30
115
FD30
116
FD30
118
FD30
119
FD30
120
FD30
121
FD30
123
FD30
124
FD30
125
FD60
126
FD30 127
FD30
128
FD30
129
FD30
133
FD30
130
FD30
132
FD30
138
FD30
140
FD30
172
FD60
140
FD30
137
FD30
136
FD30
135
FD30
134
FD30
142
FD30
143
FD30
144
FD30
145
FD30
146
FD30
148
FD30
149
FD30
150
FD30
151
FD60
152
FD30
153
FD30
154
FD30
155
FD30
156
FD30
158
FD30
159
FD30
137
FD30
160
FD30
162
FD30
163
FD30
141
FD30
142
FD30
164
FD30
166
FD30
167
FD30
168
FD30
147
FD30
169
FD30
149
FD30
171
FD30
170
FD30
152
FD30
17 m²
Stairs
150
935 m²
Main Corridor
151
28 m²
Music Room
127
795075050075040075050075026075018075010057504007505007504007504007504007505007504007505607504007505007504007505007504007504407504607507504407504607504407504607504207504007505807504207504207504607504407504607504207504007505807504007504407504607504407504607504207504007506007504007504207504607504407504607504407504007505607504007504407504007509657502407504847509506
570240024002400240024002400240024002400240024002400240024002400240024002400240024002400
102990
570 2400 2400 2400 2600 2600 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2600 2600 2400 2400 2400 2400 2400 570
107540
1220240024002400240024002400240024002600260024002400240024002400240024002400240024002400240024002400240024002400240024002400240024002400240024002400240024002400570
95790
23220 6840 938 750 300 750 400 750 625 750 708 750 400 750 700 750 292 758 500 750 920 540 750 540 750 500 750 500 750 500 750 300 750 820
57024002400240024002400260026002400240024002400240024002400240024002400240024002400240024002400240024002400240024002400240024002400240024002400240024002400570 2400 2400 2400 2600 2600 2400
107540
800 750 500 750 400 750 500 750 300 750200750 3620 750 400 750 500 750 500 750 300 750 600 750 300 750 600 750 300 750 600 750 300 750 600 750 300 750 600 750 300 750 600 750 300 750 600 750 300 750 600 750 300 750 600 750 300 750 600 750 300 750 600 750 300 750 600 750 300 750 600 750 300 750 600 750 7920
795 750 400 750 500 758 392 750200750 400 750 3375 750 300 750 300 750 1030 750 300 750 300 750 653 750 380 750 600 750 375 750 525 750 300 750 600 750 300 750 600 750 300 750 418 750 250 750 833 750 400 750 500 750 400 750 500 750 400 750 500 750 400 750 500 750 400 750 500 750 400 750 500 750 400 750 380 750 400 75088 34140 100750 300 750 600 750 300 750 800 750 300 750193750 500 750 1000 750 300 750 600 750 300 750 600 750 300 750 808 60750200750220750 520 750 800
102508207504007505007504007505007504007505007501050318075020075010082075040075060075040075050075028875052575030075060075030075060075040075050075028875061375040075040075040075070075030075040075033875066375010506007502887506137504007505007504007505007504007504007504007507007502007507007503007505007504007505007502887506137502887506137503007506007503757504257504007507007503007505007503007506007503007509085207501130
105
FD60
108
FD60
111
FD60
114
FD60
117
FD60
122
FD60
131
FD60
139
FD60
141
FD60
147
FD60
157
FD60
161
FD60
165
FD60
Void Over General Purpose/Dining Area
2711810319
1248 1010 143
9651010425
10901010300
395 1810 395
395 1810 395
35010101040
395 1810 395
1128101052510101128
395 1810 395
1128101052510101128
395 1810 395
1128101052510101128
395 1810 395
1128101052510101128
695101095810101128
395 1810 395
1128101052510101128
10401010350
140 1810 800 2428 1010 1563 1090 1010300 1128 10105251010 1128
3951810395
1090 1010300
3951810395
3951810395
3951810395
738 1010652
1128 10105251010 1128
3381010 1053
1128 1010 525 10101128 1127 1010525 10101128 1040 1010 350 11281010 525 10101128 1040 10107001010 1040
350 10101040 1290 1010300
10401010350124010103503951810395350101010401040101070010101040
1128101052510101128
395 1810 395
10401010350
11401010250
1128101052510101128
395 1810 395
35010101040
11401010250
11401010250
1127101052510101128
395 1810 395
1040101070010101040
11401010 250
11401010250
10401010350
1345 1010245
2390 1010490 1010300
3951810395
200mm Exposed Polished
Finish Blockwork Partition
Wall 60min Fire Rating
125mm Steel Stud Partition
Internal Wall 60min Fire
Rating
200mm Exposed Polished
Finish Blockwork Partition
Wall 60min Fire Rating
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
200mm Exposed Polished
Finish Blockwork Partition
Wall 60min Fire Rating
Glass handrail at a height of
900mm
4407504607502007504537502007508598
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
200mm Exposed Polished
Finish Blockwork Partition
Wall 60min Fire Rating
Glass handrail at a height of
900mm
125mm Steel Stud Partition
Internal Wall 60min Fire
Rating
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004
Glass handrail at a height of
900mm
125mm Steel Stud Partition
Internal Wall 60min Fire
Rating
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004
200mm Exposed Polished
Finish Blockwork Partition
Wall 60min Fire Rating
300mm Square Primary
Structure Precast Concrete
Column in accordance with
BS En 1992-1-2:2004
300mm Square Primary
Structure Precast Concrete
Column in accordance with
BS En 1992-1-2:2004
Glass handrail at a height of
900mm
200mm Exposed Polished
Finish Blockwork Partition
Wall 60min Fire Rating
125mm Steel Stud Partition
Internal Wall 60min Fire
Rating
125mm Steel Stud Partition
Internal Wall 60min Fire
Rating
200mm Exposed Polished
Finish Blockwork Partition
Wall 60min Fire Rating
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
8
9
10
11
12
13
14 15
16
17
18
19
20
21
8
9
10
11
12
13
1415
16
17
18
19
20
21
8
9
10
11
12
13
1415
16
17
18
19
20
21
8
9
10
11
12
13
1415
16
17
18
19
20
21
2
3
4
5
6
7
8
9
10
11
21
20
19
18
17
16
15
14
13
12
2
3
4
5
6
7
8
9
10
11
21
20
19
18
17
16
15
14
13
12
DN DN
DN
DN
DN
DN
Void Over Gym/Sports Hall
First Floor Legend
Void Openings
Void Openings Above
Wheelchair Access Circle
Direction of water flow
Rain water gutters
180mm x180mm hopper
head gutter
Scale
LECTURER
Drawn by
Date
Project number
Institute of Technology Carlow
BSc. (Hons) in Architectural Technology
Year 4 2013-2014
1 : 200
First Floor Level Plan
2
Studio Thesis: School Building of
the Future
02-May-2014
Edel Fox
Nole Dunne, Sujana Sudhir
& Dan O' Sullivan
GATPFF103
1 : 200
First Floor Level1
First Floor Door Schedule
Level Family and Type Height Width Fire Rating Count
First Floor Level IntDbl (5): 1810 x 2110mm 2110 1810 FD60 18
First Floor Level Internal Classroom Doors: 1010 x 2110mm 2110 1010 FD30 40
First Floor Level Internal Door Frosted Glass Triple Panel: 1010 x 2110mm 2110 1010 FD30 10
First Floor Level Internal Door Frosted Glass: 1010 x 2110mm 2110 1010 FD30 12
Grand total: 80
First Floor Window Schedule
Level Family and Type Height Width Count
First Floor Level Bathroom Window: Bathroom
Window
1500 750 36
First Floor Level Window A: Window A 1500 750 390
First Floor Level Window B: Window B 500 750 264
First Floor Level Window C: Window C 500 750 153
First Floor Level Window D: Window D 2000 1000 11
Grand total: 854
First Floor Room Schedule
Number Name Level Area Department
Administrative
87 Pastoral Office First Floor Level 20 m² Administrative
106 Pastoral Office First Floor Level 17 m² Administrative
112 Deputy Principal Office First Floor Level 21 m² Administrative
113 Deputy Principal Office First Floor Level 21 m² Administrative
114 Principal Office First Floor Level 21 m² Administrative
129 Pastoral Office First Floor Level 21 m² Administrative
Classroom
99 Classroom 26 First Floor Level 52 m² Classroom
100 Classroom 25 First Floor Level 51 m² Classroom
101 Classroom 24 First Floor Level 51 m² Classroom
102 Classroom 23 First Floor Level 51 m² Classroom
103 Classroom 22 First Floor Level 51 m² Classroom
104 Classroom 21 First Floor Level 51 m² Classroom
108 Demonstration Room First Floor Level 70 m² Classroom
111 Maths Room First Floor Level 69 m² Classroom
115 Maths Room First Floor Level 69 m² Classroom
116 Classroom 20 First Floor Level 51 m² Classroom
117 Classroom 19 First Floor Level 51 m² Classroom
118 Classroom 18 First Floor Level 51 m² Classroom
119 Classroom 17 First Floor Level 52 m² Classroom
132 Classroom 16 First Floor Level 51 m² Classroom
133 Classroom 15 First Floor Level 51 m² Classroom
136 Classroom 14 First Floor Level 51 m² Classroom
138 Classroom 13 First Floor Level 51 m² Classroom
139 Classroom 12 First Floor Level 51 m² Classroom
140 Classroom 11 First Floor Level 51 m² Classroom
142 Classroom 10 First Floor Level 51 m² Classroom
143 Classroom 9 First Floor Level 51 m² Classroom
Health and Fitness
122 Fitness Suite First Floor Level 140 m² Health and Fitness
123 Male Changing Room First Floor Level 14 m² Health and Fitness
124 Female Changing Room First Floor Level 14 m² Health and Fitness
Kitchen
149 Staff Room First Floor Level 173 m² Kitchen
Maintenance
121 Switch Room First Floor Level 10 m² Maintenance
Storage
86 Store Room First Floor Level 28 m² Storage
90 Science Preperation Room First Floor Level 56 m² Storage
93 Science Preperation Room First Floor Level 56 m² Storage
96 Science Preperation Room First Floor Level 56 m² Storage
105 Store Room First Floor Level 28 m² Storage
128 Project Store First Floor Level 21 m² Storage
135 Store Room First Floor Level 16 m² Storage
Toilets
109 Female Toilets First Floor Level 35 m² Toilets
110 Male Toilets First Floor Level 32 m² Toilets
125 Male Toilets First Floor Level 25 m² Toilets
126 Female Toilets First Floor Level 25 m² Toilets
146 Male Toilets First Floor Level 11 m² Toilets
147 Female Toilets First Floor Level 13 m² Toilets
Travel
88 Corridor First Floor Level 4 m² Travel
107 Stairs First Floor Level 17 m² Travel
121 Corridor First Floor Level 4 m² Travel
130 Stairs First Floor Level 15 m² Travel
145 Stairs First Floor Level 19 m² Travel
148 Corridor First Floor Level 5 m² Travel
150 Stairs First Floor Level 17 m² Travel
151 Main Corridor First Floor Level 935 m² Travel
Workshop
89 Science Laboratory First Floor Level 87 m² Workshop
91 Science Laboratory First Floor Level 85 m² Workshop
92 Science Laboratory First Floor Level 85 m² Workshop
94 Science Laboratory First Floor Level 85 m² Workshop
95 Science Laboratory First Floor Level 85 m² Workshop
97 Business/Computer Room First Floor Level 85 m² Workshop
98 Business/Computer Room First Floor Level 85 m² Workshop
127 Music Room First Floor Level 28 m² Workshop
131 Design & Communication Graphics First Floor Level 87 m² Workshop
134 Social Studies First Floor Level 69 m² Workshop
137 Social Studies First Floor Level 69 m² Workshop
141 Art Room First Floor Level 103 m² Workshop
144 Art Room First Floor Level 105 m² Workshop
Grand total: 66
General Notes:
-All works to comply with current building
regulations and code of practice.
-All works must be done to the
satisfaction of the building control officer.
-All dimensions in mm unless otherwise
noted.
-Drawings must not be scaled, written
dimensions must be followed.
-Primary structure precast concrete
columns to be placed on the intersection
of grid lines as shown.
- Primary structure precast concrete
beams to span along gridlines and to be
cast in place with a precast concrete
column above and below.
-External walls not placed along
gridlines, walls to be placed to the outer
face of the precast concrete column
unless otherwise stated.
-Internal walls of the sports hall to be
placed in between the precast concrete
columns as indicated on the plan.
-Primary structure precast concrete
columns and beams to be in accordance
with BS EN 1992-1-2:2004.
-Solid wall precast concrete panels to be
in accordance with BS EN 1992-1-
2:2004.
-Precast concrete for lift shaft and stair
shaft to comply with BS EN 1992-1-
2:2004.
-Lift and stair shaft to be 60min fire proof
including access doors.
-All escape fire doors to be 60min fire
rated and fitted with automatic closers.
-Floor finish to be non-slip vinyl flooring
and terrazzo flooring.
-Entrance area to have a minimum level
landing within 1800mm of entrance door.
Specification:
Primary Structure – 300mm x 300mm reinforced
precast concrete columns to be placed at grid line
intersections as shown in the plan. 450mm x 500mm
edge beams and 600mm x 500mm inverted T beams
to be used to structurally support the flooring slabs.
Reinforcements to be in accordance with structural
engineers specifications and where possible to be
recycled steel.
Structural Foundations – Each primary structure
300mm x 300mm square precast concrete column to
be connected back to its own individual precast
concrete pocket foundation. Each precast concrete
column will vary in depth depending on the slope of
the ground beneath. The rest of the building is to be
structurally supported below by a reinforced raft
foundation. Steel reinforcements to be in
accordance with engineers specifications. The raft
foundation is to be wrapped around the precast
concrete columns.
Ground Floor Build Up – 50mm sand blinding to be
placed onto the ground, a layer of DPM is to be
lapped and sealed and placed above the sand
blinding, 100mm Expanded Polystyrene (EPS) rigid
foam insulation to create a continuous barrier which
will eliminate cold bridges around the foundation.
Then a structural raft foundation is to be put in place
with reinforcements to be in accordance with
engineer’s specifications, and the cast in situ
concrete to be in accordance with BS EN 1992-1-
2:2004. Followed with a layer of 100mm structural
screed topping, finished with either a layer of 60mm
terrazzo floor finish or a vinyl floor finish depending
on the room use.
Intermediate Floor Build Up – The main structure
of the floor is made up of 200mm precast concrete
hollowcore flooring slabs in accordance with BS EN
1992-1-2:2004. This is followed by a layer of 100mm
structural screed which casts the rebars into place
tying the hollowcore flooring slabs back to the
precast concrete edge beams. The floor is finished
with either a layer of 60mm terrazzo floor finish or a
vinyl floor finish depending on the room use.
Roof Build Up – The main structure of the roof is
made up of 200mm precast concrete hollowcore
slabs in accordance with BS EN 1992-1-2:2004. This
is followed by a layer of 100mm structural screed
which casts the rebars into place tying the hollowcore
flooring slabs back to the precast concrete edge
beams. This is followed by a vapour control layer
applied directly to the structural screed. Followed by
a layer of 150mm Expanded Polystyrene (EPS) rigid
foam insulation, to eliminate cold bridges along the
roof deck. Applied directly to the insulation is a
waterproofing membrane to stop water penetration.
The roof is finished with a layer of single ply EDPM
waterproofing membrane.
External Wall Build Up – From Exterior: 8mm
external render finish applied directly onto mesh
reinforcement, mesh reinforcement to apply render
finish to, 12mm cement particle board fixed @ 600mm
c/c, 200mm x 100mm steel U-channels fixed back to
the precast concrete wall panels @ 600mm c/c put in
place to support the cement particle board, with
200mm expanded polystyrene (EPS) rigid foam
insulation in between, finished with 200mm solid wall
precast concrete panels in accordance with BS EN
1992-1-2:2004 with an exposed internal finish.
Internal Wall Build Up – Stud Partition: Double
layer of 12.5mm gyproc board fixed back to 75mm
steel c channels with 75mm mineral wool insulation in
between, finished with a double layer of gyproc board
with a minimum of a 60min Fire Rating.
Blockwork: 200mm Exposed Polished Finish
Blockwork Partition Wall with a minimum of a 60min
Fire Rating.
*Window Tags Omitted For Clarity On Drawing
4. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
AA
BB
CC
DD
EE
FF
GG
HH
II
JJ
KK
LL
MM
NN
OO
PP
QQ
RR
SS
7790
12360
1220240024002400240024002400240024002600260024002400240024002400240024002400240024002400570240024002400240024002400240024002400240024002400240024002400240024002400240024002400
102990
570 2400 2400 2400 2600 2600 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2600 2600 2400 2400 2400 2400 2400 570
107540
1220240024002400240024002400240024002600260024002400240024002400240024002400240024002400240024002400240024002400240024002400240024002400240024002400240024002400570
95790
57024002400240024002400260026002400240024002400240024002400240024002400240024002400240024002400240024002400240024002400240024002400240024002400240024002400570 2400 2400 2400 2600 2600 2400
107540
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
200mm Precast Concrete
Hollowcore slabs to BS EN
1992-1-2:2004, 100mm
Structural Screed, 150mm
EPS Rigid Foam Insulation,
Single Ply EDPM
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Reynaers Eco System 50
insulated sloped roof glazing
Reynaers Eco System 50
insulated sloped roof glazing
200mm Precast Concrete
Hollowcore slabs to BS EN
1992-1-2:2004, 100mm
Structural Screed, 150mm
EPS Rigid Foam Insulation,
Single Ply EDPM
200mm Precast Concrete
Hollowcore slabs to BS EN
1992-1-2:2004, 100mm
Structural Screed, 150mm
EPS Rigid Foam Insulation,
Single Ply EDPM
200mm Precast Concrete
Hollowcore slabs to BS EN
1992-1-2:2004, 100mm
Structural Screed, 150mm
EPS Rigid Foam Insulation,
Single Ply EDPM
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
200mm Precast Concrete
Hollowcore slabs to BS EN
1992-1-2:2004, 100mm
Structural Screed, 150mm
EPS Rigid Foam Insulation,
Single Ply EDPM
Reynaers Eco System 50
insulated sloped roof glazing
Reynaers Eco System 50
insulated sloped roof glazing
Reynaers Eco System 50
insulated sloped roof glazing
200mm Precast Concrete
Hollowcore slabs to BS EN
1992-1-2:2004, 100mm
Structural Screed, 150mm
EPS Rigid Foam Insulation,
Single Ply EDPM
200mm Precast Concrete
Hollowcore slabs to BS EN
1992-1-2:2004, 100mm
Structural Screed, 150mm
EPS Rigid Foam Insulation,
Single Ply EDPM
Reynaers Eco System 50
insulated sloped roof glazing
200mm Precast Concrete
Hollowcore slabs to BS EN
1992-1-2:2004, 100mm
Structural Screed, 150mm
EPS Rigid Foam Insulation,
Single Ply EDPM
Reynaers Eco System 50
insulated sloped roof glazing
200mm Precast Concrete
Hollowcore slabs to BS EN
1992-1-2:2004, 100mm
Structural Screed, 150mm
EPS Rigid Foam Insulation,
Single Ply EDPM
200mm Precast Concrete
Hollowcore slabs to BS EN
1992-1-2:2004, 100mm
Structural Screed, 150mm
EPS Rigid Foam Insulation,
Single Ply EDPM
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
200mm Precast Concrete
Hollowcore slabs to BS EN
1992-1-2:2004, 100mm
Structural Screed, 150mm
EPS Rigid Foam Insulation,
Single Ply EDPM
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
180mm x180mm hopper
head gutter fixed back to
the face of the building
Insulated gutter to
catch rainwater run off
from the parapet and
the roof
900mm height protective
railing around roof to allow
safe access to roof area
900mm height protective
railing around roof to allow
safe access to roof area
900mm height protective
railing around roof to allow
safe access to roof area
Roof mounted
Monocrystaline Photovoltaic
Panels
Roof mounted
Monocrystaline
Photovoltaic Panels
Roof mounted
Monocrystaline
Photovoltaic Panels
Roof mounted
Monocrystaline
Photovoltaic Panels
180mm x180mm hopper
head gutter fixed back
to the face of the
building
Insulated gutter to
catch rainwater run off
from the parapet and
the roof
Roof Level Plan Legend
Direction of rain water flow
Rain water gutters
180mm x180mm hopper
head gutter
Proposed position of
rainwater harvesting
tanks
Underground water
pipes
Direction of rain water
flow within pipes
Scale
LECTURER
Drawn by
Date
Project number
Institute of Technology Carlow
BSc. (Hons) in Architectural Technology
Year 4 2013-2014
1 : 200
Roof Level Plan
2
Studio Thesis: School Building of
the Future
02-May-2014
Edel Fox
Noel Dunne, Sujana Sudhir
& Dan O' Sullivan
GATPRL104
1 : 200
Roof Level Plan1
Specification:
Roof Build Up – The main structure of the roof is made up
of 200mm precast concrete hollowcore slabs in
accordance with BS EN 1992-1-2:2004. This is followed
by a layer of 100mm structural screed which casts the
rebars into place tying the hollowcore flooring slabs back
to the precast concrete edge beams. This is followed by a
vapour control layer applied directly to the structural
screed. Followed by a layer of 150mm Expanded
Polystyrene (EPS) rigid foam insulation, to eliminate cold
bridges along the roof deck. Applied directly to the
insulation is a waterproofing membrane to stop water
penetration. The roof is finished with a layer of single ply
EDPM waterproofing membrane.
External Wall Build Up – From Exterior: 8mm external
render finish applied directly onto mesh reinforcement,
mesh reinforcement to apply render finish to, 12mm
cement particle board fixed @ 600mm c/c, 200mm x
100mm steel U-channels fixed back to the precast
concrete wall panels @ 600mm c/c put in place to support
the cement particle board, with 200mm expanded
polystyrene (EPS) rigid foam insulation in between,
finished with 200mm solid wall precast concrete panels in
accordance with BS EN 1992-1-2:2004 with an exposed
internal finish.
Curtain Walling Specification:
Curtain Wall CW 50
-Manufacturer: Reynaers Ltd
-Product reference: Curtain Wall CW 50 Standard
/Curtain Wall CW 50-FP EW 30
/Curtain Wall CW 50-FP EW 60 /Curtain Wall CW
50- HL /Curtain Wall CW 50-RA
-Internal framing member: Extruded aluminium
- Finish: Anodized /Polyester powder coated
- Colour: White
-External cover cap: Extruded aluminium
- Finish: Anodized /Polyester powder coated
- Colour: White
-Windows: Fixed light (CW50-FP) /Glazed in windows
- Configuration: Horizontal pivot /Parallel opener
/Side hung /Tilt and turn /Top hung
-Glazing: Insulating glass units /Single glazed panes
-Glazing system: Dry glazed gasket
Aircool Ventilators Specifications:
-Manufacturer: Passivent
-Frame and external weather lourves: extruded aluminium,
with ABS thermal break
-Insect screen 4mm black polypropylene
-Internal cover grille: extruded aluminium
-Size: 1200mm x 1200mm x 180mm
-White polyester coated
-Class 1 fire rating in accordance with BS 476: Part 7:
1987
-Weather performance in accordance with BS EN 13030:
2001
-Air leakage performance in accordance with BS 6375:
Part 1: 1989
-Controls: 24V modulating actuators, control sensors to be
put in place to consider temperature, CO₂, humidity and
wind
5. Ground Floor Level
0
First Floor Level
3760
Parapet Level
7620
Parapet 2 Ventilation
Stacks
9120
Gym Parapet Level
12360
ABCDEFGHIJKLMNOPQRSTUVWXYZAABBCCDDEEFFGGHHIIJJKKLLMMNNOOPPQQRRSS
3240150038603760
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Reynaers Eco System 50
insulated and Ventilated
Windows
External double opening fire
escape door
Colt Shadovoltaic
Photovoltaic Louvre
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Reynaers Eco System 50
insulated and Ventilated
Windows
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
Colt Shadovoltaic
Photovoltaic Louvre
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
3mm Aluminium parapet coping
3mm Aluminium parapet coping
3mm Aluminium parapet coping
Passivent Aircool Ventilator
Passivent Aircool Ventilator
Reynaers Eco System 50
insulated and Ventilated
Windows
Ground Floor Level
0
First Floor Level
3760
Parapet Level
7620
Parapet 2 Ventilation
Stacks
9120
Gym Parapet Level
12360
12345678910111213141516171819202122232425262728293031323334353637383940414243444546
3760386015003240
Reynaers Eco System 50
insulated and Ventilated
Windows
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Colt Shadovoltaic
Photovoltaic Louvre
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Reynaers Eco System 50
insulated and Ventilated
Windows
Reynaers Eco System 50
insulated and Ventilated
Windows
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
3mm Aluminium parapet coping
Reynaers Eco System 50
insulated and Ventilated
Windows
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Colt Shadovoltaic
Photovoltaic Louvre
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
Reynaers Eco System 50
insulated and Ventilated
Windows
External double opening fire
escape door
Colt Shadovoltaic
Photovoltaic Louvre
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
3mm Aluminium parapet coping3mm Aluminium parapet coping
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
Ground Floor Level
0
First Floor Level
3760
Parapet Level
7620
Parapet 2 Ventilation
Stacks
9120
Gym Parapet Level
12360
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
3240150038603760
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
External double opening fire
escape door
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
Reynaers Eco System 50
insulated and Ventilated
Windows
3mm Aluminium parapet coping
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
Passivent Aircool Ventilator
Reynaers Eco System 50
insulated and Ventilated
Windows
Passivent Aircool Ventilator
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Reynaers Eco System 50
insulated and Ventilated
Windows
Passivent Aircool Ventilator
Reynaers Eco System 50
insulated and Ventilated
Windows
Reynaers Eco System 50
insulated and Ventilated
Windows
3mm Aluminium parapet coping
Reynaers CS 86 – HI Highly
Energy Efficient low E glass
door
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
3mm Aluminium parapet coping
12mm Tegral Pictura fibre
cement cladding panels in
accordance with EN 12467
12mm Tegral Pictura fibre
cement cladding panels in
accordance with EN 12467
Ground Floor Level
0
First Floor Level
3760
Parapet Level
7620
Parapet 2 Ventilation
Stacks
9120
Gym Parapet Level
12360
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA BB CC DD EE FF GG HH II JJ KK LL MM NN OO PP QQ RR SS
3240150038603760
3mm Aluminium parapet coping
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
Reynaers Eco System 50
insulated and Ventilated
Windows
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
Reynaers Eco System 50
insulated and Ventilated
Windows
Reynaers Eco System 50
insulated and Ventilated
Windows
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
3mm Aluminium parapet coping
3mm Aluminium parapet coping
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Scale
LECTURER
Drawn by
Date
Project number
Institute of Technology Carlow
BSc. (Hons) in Architectural Technology
Year 4 2013-2014
1 : 200
External Elevations
2
Studio Thesis: School Building of
the Future
02-May-2014
Edel Fox
Noel Dunne, Sujana Sudhir
& Dan O' Sullivan
GATPEE105
1 : 200
East Elevation1
1 : 200
North Elevation2
1 : 200
South Elevation3
1 : 200
West Elevation4
Curtain Walling Specification:
Curtain Wall CW 50
-Manufacturer: Reynaers Ltd
-Product reference: Curtain Wall CW 50 Standard
/Curtain Wall CW 50-FP EW 30
/Curtain Wall CW 50-FP EW 60 /Curtain Wall CW
50- HL /Curtain Wall CW 50-RA
-Internal framing member: Extruded aluminium
- Finish: Anodized /Polyester powder coated
- Colour: White
-External cover cap: Extruded aluminium
- Finish: Anodized /Polyester powder coated
- Colour: White
-Windows: Fixed light (CW50-FP) /Glazed in windows
- Configuration: Horizontal pivot /Parallel opener
/Side hung /Tilt and turn /Top hung
-Glazing: Insulating glass units /Single glazed panes
-Glazing system: Dry glazed gasket
Window Specification:
Windows – Aluminium – Clad Timber – Manufacturer -
Carlson
-Glass – Double glazing with low E glass – argon filled-
thermal conductivity 1.0 W/m²k
Toughened safety glass for windows installed
below 800mm above ground level
-Frame – Internal: Softwood thermal conductivity 0.13
W/m²k in accordance with ISO 10077-2:2003
External: Recycled aluminium
-Overall U-value of 1.35W/m²k achieving an A rating
-Manufactured to comply with BS 644:2012
-Weather performance must be tested in accordance with
BS 6375-1
-Security performance must be tested to BS EN 1627-
1630
Door Specification:
Doors – System – Reynaers CS 86 – HI Highly Energy
Efficient
Glass - Double glazing with low E glass – argon filled-
thermal conductivity 1.0 W/m²k
Toughened safety glass for glass panes installed
below 800mm above ground level
Frame – Aluminium inward opening flush door 68mm
Vent – 76mm
U-Value – 1.35W/m²k achieving an A rating
Thermal insulation must be tested in accordance with EN
ISO 10077-2
Acoustic performance must be tested in accordance with
EN ISO 140-3, EN ISO 717-1
Burglar resistance must be tested in accordance with
NEN 5096-ENV1627
Fibre – Cement Cladding Panel Specification:
Tegral Pictura fibre cement cladding panels:
-Tegral Pictura fibre cement cladding panels are to be
applied to the main entrance of the building only. This is
to be a statement wall and to provide clarity on the
location of the main entrance of the building to avoid
confusion.
-Cladding panels to be 12mm thick.
-To be in compliance with EN 12467.
-Cladding panels to be used in accordance with
Tegframe light gauge steel framing system.
-Panels are to have rivet fixings back to the secondary
steel frame.
-Fixings must be a minimum of 80mm from the corner of
each panel.
-A minimum of an 8mm shadow gap must be left between
each panel to create the effect of a secret fixing system.
-A mix and match of three coloured cladding panels to be
used throughout the building.
Tegral Pictura Red PI 341
Tegral Pictura White PI 141
Tegral Pictura Blue PI 441
-All works to be done to manufacturers specifications.
General Notes:
-All works to comply with current building
regulations and code of practice.
-All works must be done to the
satisfaction of the building control officer.
-All dimensions in mm unless otherwise
noted.
-Drawings must not be scaled, written
dimensions must be followed.
-Primary structure precast concrete
columns and beams to be in accordance
with BS EN 1992-1-2:2004.
-Solid wall precast concrete panels to be
in accordance with BS EN 1992-1-2:2004.
-Precast concrete for lift shaft and stair
shaft to comply with BS EN 1992-1-
2:2004.
External Wall Build Up – From Exterior:
8mm external render finish applied
directly onto mesh reinforcement, mesh
reinforcement to apply render finish to,
12mm cement particle board fixed @
600mm c/c, 200mm x 100mm steel U-
channels fixed back to the precast
concrete wall panels @ 600mm c/c put in
place to support the cement particle
board, with 200mm expanded polystyrene
(EPS) rigid foam insulation in between,
finished with 200mm solid wall precast
concrete panels in accordance with BS
EN 1992-1-2:2004 with an exposed
internal finish.
Roof Build Up – The main structure of
the roof is made up of 200mm precast
concrete hollowcore slabs in accordance
with BS EN 1992-1-2:2004. This is
followed by a layer of 100mm structural
screed which casts the rebars into place
tying the hollowcore flooring slabs back to
the precast concrete edge beams. This
is followed by a vapour control layer
applied directly to the structural screed.
Followed by a layer of 150mm Expanded
Polystyrene (EPS) rigid foam insulation,
to eliminate cold bridges along the roof
deck. Applied directly to the insulation is
a waterproofing membrane to stop water
penetration. The roof is finished with a
layer of single ply EDPM waterproofing
membrane.
Solar Shading Specifications:
-Colt shadovoltaic solar shading system
with integrated photovoltaic cells into the
glass louvres
-Manufacturer: Colt
-Carrier system 4
-Metal frame coating in a weatherproof
white paint
-Glass to span in lengths of 1000mm
-Glass to span in widths of 600mm
-Angle of rotation 0-85°
Controls:
-Electronically operated via actuators
-SolTronic controls to be used
Aircool Ventilators Specifications:
-Manufacturer: Passivent
-Frame and external weather lourves:
extruded aluminium, with ABS thermal
break
-Insect screen 4mm black polypropylene
-Internal cover grille: extruded aluminium
-Size: 1200mm x 1200mm x 180mm
-White polyester coated
-Class 1 fire rating in accordance with BS
476: Part 7: 1987
-Weather performance in accordance with
BS EN 13030: 2001
-Air leakage performance in accordance
with BS 6375: Part 1: 1989
-Controls: 24V modulating actuators,
control sensors to be put in place to
consider temperature, CO₂, humidity and
wind
6. Ground Floor Level
0
First Floor Level
3760
Parapet Level
7620
Parapet 2 Ventilation
Stacks
9120
Gym Parapet Level
12360
GHIJKLMNOPQRSTUVWXYZAABBCCDDEEFFGGHHIIJJKKLLMMNNOOPPQQRR
3760386015003240
3mm Aluminim parapet coping
Reynaers Eco System 50
insulated and Ventilated
Windows
Passivent Aircool Ventilator
Reynaers Eco System 50
insulated and Ventilated
Windows
Passivent Aircool Ventilator
3mm Aluminim parapet coping
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
Colt Shadovoltaic
Photovoltaic Louvre
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Reynaers CS 86 – HI Highly
Energy Efficient low E glass
door
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
Colt Shadovoltaic
Photovoltaic Louvre
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
16
Ground Floor Level
0
First Floor Level
3760
Parapet Level
7620
Parapet 2 Ventilation
Stacks
9120
Gym Parapet Level
12360
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA BB CC DD EE FF GG HH II JJ KK LL MM NN OO
3760386015003240
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
Reynaers CS 86 – HI Highly
Energy Efficient low E glass
door
External double opening fire
escape door
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
3mm Aluminium parapet coping3mm Aluminium parapet coping
Reynaers Eco System 50
insulated and Ventilated
Windows
Reynaers Eco System 50
insulated and Ventilated
Windows
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
92 113
Ground Floor Level
0
First Floor Level
3760
Parapet Level
7620
Parapet 2 Ventilation
Stacks
9120
Gym Parapet Level
12360
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45
3240150038603760
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
12mm Tegral Pictura fibre
cement cladding panels in
accordance with EN 12467
Reynaers CS 86 – HI Highly
Energy Efficient low E glass
door
12mm Tegral Pictura fibre
cement cladding panels in
accordance with EN 12467
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
Passivent Aircool Ventilator
Reynaers Eco System 50
insulated and Ventilated
Windows
Reynaers Eco System 50
insulated and Ventilated
Windows
Passivent Aircool Ventilator
Reynaers Eco System 50
insulated and Ventilated
Windows
Passivent Aircool Ventilator
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
3mm Aluminium parapet coping
3mm Aluminium parapet coping
52
Ground Floor Level
0
First Floor Level
3760
Parapet Level
7620
Parapet 2 Ventilation
Stacks
9120
Gym Parapet Level
12360
123456789101112131415161718192021222324252627282930313233343536373839404142434445
3760386015003240
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Colt Shadovoltaic
Photovoltaic Louvre
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Colt Shadovoltaic
Photovoltaic Louvre
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
3mm Aluminium parapet coping3mm Aluminium parapet coping3mm Aluminium parapet coping
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Scale
LECTURER
Drawn by
Date
Project number
Institute of Technology Carlow
BSc. (Hons) in Architectural Technology
Year 4 2013-2014
1 : 200
Courtyard Elevations
2
Studio Thesis: School Building of
the Future
02-May-2014
Edel Fox
Noel Dunne, Sujana Sudhir
& Dan O' Sullivan
GATPCE106
1 : 200
North East Elevation1
1 : 200
South West Elevation2
1 : 200
South East Elevation3
1 : 200
North West Elevation4
Curtain Walling Specification:
Curtain Wall CW 50
-Manufacturer: Reynaers Ltd
-Product reference: Curtain Wall CW 50 Standard
/Curtain Wall CW 50-FP EW 30
/Curtain Wall CW 50-FP EW 60 /Curtain Wall CW
50- HL /Curtain Wall CW 50-RA
-Internal framing member: Extruded aluminium
- Finish: Anodized /Polyester powder coated
- Colour: White
-External cover cap: Extruded aluminium
- Finish: Anodized /Polyester powder coated
- Colour: White
-Windows: Fixed light (CW50-FP) /Glazed in windows
- Configuration: Horizontal pivot /Parallel opener
/Side hung /Tilt and turn /Top hung
-Glazing: Insulating glass units /Single glazed panes
-Glazing system: Dry glazed gasket
Window Specification:
Windows – Aluminium – Clad Timber – Manufacturer -
Carlson
-Glass – Double glazing with low E glass – argon filled-
thermal conductivity 1.0 W/m²k
Toughened safety glass for windows installed
below 800mm above ground level
-Frame – Internal: Softwood thermal conductivity 0.13
W/m²k in accordance with ISO 10077-2:2003
External: Recycled aluminium
-Overall U-value of 1.35W/m²k achieving an A rating
-Manufactured to comply with BS 644:2012
-Weather performance must be tested in accordance with
BS 6375-1
-Security performance must be tested to BS EN 1627-1630
Door Specification:
Doors – System – Reynaers CS 86 – HI Highly Energy
Efficient
Glass - Double glazing with low E glass – argon filled-
thermal conductivity 1.0 W/m²k
Toughened safety glass for glass panes installed
below 800mm above ground level
Frame – Aluminium inward opening flush door 68mm
Vent – 76mm
U-Value – 1.35W/m²k achieving an A rating
Thermal insulation must be tested in accordance with EN
ISO 10077-2
Acoustic performance must be tested in accordance with
EN ISO 140-3, EN ISO 717-1
Burglar resistance must be tested in accordance with NEN
5096-ENV1627
Fibre – Cement Cladding Panel Specification:
Tegral Pictura fibre cement cladding panels:
-Tegral Pictura fibre cement cladding panels are to be
applied to the main entrance of the building only. This is to
be a statement wall and to provide clarity on the location of
the main entrance of the building to avoid confusion.
-Cladding panels to be 12mm thick.
-To be in compliance with EN 12467.
-Cladding panels to be used in accordance with Tegframe
light gauge steel framing system.
-Panels are to have rivet fixings back to the secondary steel
frame.
-Fixings must be a minimum of 80mm from the corner of
each panel.
-A minimum of an 8mm shadow gap must be left between
each panel to create the effect of a secret fixing system.
-A mix and match of three coloured cladding panels to be
used throughout the building.
Tegral Pictura Red PI 341
Tegral Pictura White PI 141
Tegral Pictura Blue PI 441
-All works to be done to manufacturers specifications.
General Notes:
-All works to comply with current building
regulations and code of practice.
-All works must be done to the satisfaction
of the building control officer.
-All dimensions in mm unless otherwise
noted.
-Drawings must not be scaled, written
dimensions must be followed.
-Primary structure precast concrete
columns and beams to be in accordance
with BS EN 1992-1-2:2004.
-Solid wall precast concrete panels to be in
accordance with BS EN 1992-1-2:2004.
-Precast concrete for lift shaft and stair
shaft to comply with BS EN 1992-1-
2:2004.
External Wall Build Up – From Exterior:
8mm external render finish applied directly
onto mesh reinforcement, mesh
reinforcement to apply render finish to,
12mm cement particle board fixed @
600mm c/c, 200mm x 100mm steel U-
channels fixed back to the precast
concrete wall panels @ 600mm c/c put in
place to support the cement particle board,
with 200mm expanded polystyrene (EPS)
rigid foam insulation in between, finished
with 200mm solid wall precast concrete
panels in accordance with BS EN 1992-1-
2:2004 with an exposed internal finish.
Roof Build Up – The main structure of the
roof is made up of 200mm precast
concrete hollowcore slabs in accordance
with BS EN 1992-1-2:2004. This is
followed by a layer of 100mm structural
screed which casts the rebars into place
tying the hollowcore flooring slabs back to
the precast concrete edge beams. This is
followed by a vapour control layer applied
directly to the structural screed. Followed
by a layer of 150mm Expanded
Polystyrene (EPS) rigid foam insulation, to
eliminate cold bridges along the roof deck.
Applied directly to the insulation is a
waterproofing membrane to stop water
penetration. The roof is finished with a
layer of single ply EDPM waterproofing
membrane.
Solar Shading Specifications:
-Colt shadovoltaic solar shading system
with integrated photovoltaic cells into the
glass louvres
-Manufacturer: Colt
-Carrier system 4
-Metal frame coating in a weatherproof
white paint
-Glass to span in lengths of 1000mm
-Glass to span in widths of 600mm
-Angle of rotation 0-85°
Controls:
-Electronically operated via actuators
-SolTronic controls to be used
Aircool Ventilators Specifications:
-Manufacturer: Passivent
-Frame and external weather lourves:
extruded aluminium, with ABS thermal
break
-Insect screen 4mm black polypropylene
-Internal cover grille: extruded aluminium
-Size: 1200mm x 1200mm x 180mm
-White polyester coated
-Class 1 fire rating in accordance with BS
476: Part 7: 1987
-Weather performance in accordance with
BS EN 13030: 2001
-Air leakage performance in accordance
with BS 6375: Part 1: 1989
-Controls: 24V modulating actuators,
control sensors to be put in place to
consider temperature, CO₂, humidity and
wind
7. Ground Floor Level
0
First Floor Level
3760
Parapet Level
7620
Parapet 2 Ventilation
Stacks
9120
Gym Parapet Level
12360
45678910111213141516171819202122232425262728293031323334353637383940414243
34603003560300
2145
32605003560300100020001740
3760386015003240
900mm height protective
railing around roof to allow
safe access to roof area
200mm Precast Concrete
Hollowcore slabs to BS EN
1992-1-2:2004, 100mm
Structural Screed, 150mm
EPS Rigid Foam Insulation,
Single Ply EDPM
125mm Steel Stud Partition
Internal Wall 60min Fire
Rating
200mm Exposed Polished
Finish Blockwork Partition
Wall 60min Fire Rating
300mm Square Primary
Structure Precast Concrete
Column in accordance with
BS En 1992-1-2:2004
Reynaers Eco System 50
insulated and Ventilated
Windows
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
200mm Precast concrete
hollowcore floor slab in
accordance with BS EN
1992-1-2: 2004,100mm
structural screed,topped with
a layer of 60mm
terrazzo/vinyl floor finsh
Insitu pocket foundation to
provide a fixed base
connection to the precast
concrete column in
accordance with BS EN
1992-1-2: 2004
50mm sand blinding, DPM
layer,100mm EPS rigid foam
insulation,cast in-situ
structural raft foundation in
accordance with BS EN
1992-1-2:2004, 100mm
structural screed, topped with
60mm terrazzo/vinyl floor
finish
200mm Precast concrete
hollowcore floor slab in
accordance with BS EN
1992-1-2: 2004,100mm
structural screed,topped with
a layer of 60mm
terrazzo/vinyl floor finsh
Insitu pocket foundation to
provide a fixed base
connection to the precast
concrete column in
accordance with BS EN
1992-1-2: 2004
50mm sand blinding, DPM
layer,100mm EPS rigid foam
insulation,cast in-situ
structural raft foundation in
accordance with BS EN
1992-1-2:2004, 100mm
structural screed, topped with
60mm terrazzo/vinyl floor
finish
200mm Precast concrete
hollowcore floor slab in
accordance with BS EN
1992-1-2: 2004,100mm
structural screed,topped with
a layer of 60mm
terrazzo/vinyl floor finsh
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
Roof mounted Monocrystaline
Photovoltaic Panels
200mm Precast Concrete
Hollowcore slabs to BS EN
1992-1-2:2004, 100mm
Structural Screed, 150mm
EPS Rigid Foam Insulation,
Single Ply EDPM
200mm Exposed Polished
Finish Blockwork Partition
Wall 60min Fire Rating
Colt Shadovoltaic
Photovoltaic Louvre
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
Reynaers Eco System 50
insulated and Ventilated
Windows
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
300mm Square Primary
Structure Precast Concrete
Column in accordance with
BS En 1992-1-2:2004
Reynaers Eco System 50
insulated and Ventilated
Windows
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004
50mm sand blinding, DPM
layer,100mm EPS rigid foam
insulation,cast in-situ
structural raft foundation in
accordance with BS EN
1992-1-2:2004, 100mm
structural screed, topped with
60mm terrazzo/vinyl floor
finish
Passivent Soundscoop
620mm x 320mm x 1200mm
natural ventilation system
Passivent Soundscoop
620mm x 320mm x 1200mm
natural ventilation system
Passivent Soundscoop
620mm x 320mm x 1200mm
natural ventilation system
2733
2145
2000
2000
2110
2102
2102
2145
900
Ground Floor Level
0
First Floor Level
3760
Parapet Level
7620
Parapet 2 Ventilation
Stacks
9120
Gym Parapet Level
12360
ABCDEFGHIJKLM
3240150038603760
30035605003260
Reynaers Eco System 50
insulated and Ventilated
Windows
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
50mm sand blinding, DPM
layer,100mm EPS rigid foam
insulation,cast in-situ
structural raft foundation in
accordance with BS EN
1992-1-2:2004, 100mm
structural screed, topped with
60mm terrazzo/vinyl floor
finish
200mm Precast Concrete
Hollowcore slabs to BS EN
1992-1-2:2004, 100mm
Structural Screed, 150mm
EPS Rigid Foam Insulation,
Single Ply EDPM
Reynaers Eco System 50
insulated and Ventilated
Windows
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
300mm Square Primary
Structure Precast Concrete
Column in accordance with
BS En 1992-1-2:2004
200mm Exposed Polished
Finish Blockwork Partition
Wall 60min Fire Rating
300mm Square Primary
Structure Precast Concrete
Column in accordance with
BS En 1992-1-2:2004
900mm height protective
railing around roof to allow
safe access to roof area
Reynaers Eco System 50
insulated and Ventilated
Windows
900
200mm Precast Concrete
Hollowcore slabs to BS EN
1992-1-2:2004, 100mm
Structural Screed, 150mm
EPS Rigid Foam Insulation,
Single Ply EDPM
762
2145
Ground Floor Level
0
First Floor Level
3760
Parapet Level
7620
Parapet 2 Ventilation
Stacks
9120
G H I J K L M N O P Q R S T U V W X Y Z AA BB CC DD EE FF GG HH II JJ KK LL MM NN OO PP QQ RR
2145
30035603003460
150038603760
5001500762
2834
2145
2145
2145
2829
200200
2100
2145
762
2834
2145
2145
900
50mm sand blinding, DPM
layer,100mm EPS rigid foam
insulation,cast in-situ
structural raft foundation in
accordance with BS EN
1992-1-2:2004, 100mm
structural screed, topped with
60mm terrazzo/vinyl floor
finish
300mm Square Primary
Structure Precast Concrete
Column in accordance with
BS En 1992-1-2:2004
125mm Steel Stud Partition
Internal Wall 60min Fire
Rating
200mm Exposed Polished
Finish Blockwork Partition
Wall 60min Fire Rating
Glass handrail at a height of
900mm
50mm sand blinding, DPM
layer,100mm EPS rigid foam
insulation,cast in-situ
structural raft foundation in
accordance with BS EN
1992-1-2:2004, 100mm
structural screed, topped with
60mm terrazzo/vinyl floor
finish
300mm Square Primary
Structure Precast Concrete
Column in accordance with
BS En 1992-1-2:2004
200mm Exposed Polished
Finish Blockwork Partition
Wall 60min Fire Rating
50mm sand blinding, DPM
layer,100mm EPS rigid foam
insulation,cast in-situ
structural raft foundation in
accordance with BS EN
1992-1-2:2004, 100mm
structural screed, topped with
60mm terrazzo/vinyl floor
finish
External double opening fire
escape door
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
200mm Precast Concrete
Hollowcore slabs to BS EN
1992-1-2:2004, 100mm
Structural Screed, 150mm
EPS Rigid Foam Insulation,
Single Ply EDPM
Roof mounted Monocrystaline
Photovoltaic Panels
Reynaers Eco System 50
insulated and Ventilated
Windows
200mm Precast Concrete
Hollowcore slabs to BS EN
1992-1-2:2004, 100mm
Structural Screed, 150mm
EPS Rigid Foam Insulation,
Single Ply EDPM
Reynaers Eco System 50
insulated and Ventilated
Windows
200mm Precast Concrete
Hollowcore slabs to BS EN
1992-1-2:2004, 100mm
Structural Screed, 150mm
EPS Rigid Foam Insulation,
Single Ply EDPM
Reynaers Eco System 50
insulated and Ventilated
Windows
900mm height protective
railing around roof to allow
safe access to roof area
Glass handrail at a height of
900mm
200mm Precast concrete
hollowcore floor slab in
accordance with BS EN
1992-1-2: 2004,100mm
structural screed,topped with
a layer of 60mm
terrazzo/vinyl floor finsh
200mm Precast Concrete
Hollowcore slabs to BS EN
1992-1-2:2004, 100mm
Structural Screed, 150mm
EPS Rigid Foam Insulation,
Single Ply EDPM
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
External double opening fire
escape door
200mm Precast concrete
hollowcore floor slab in
accordance with BS EN
1992-1-2: 2004,100mm
structural screed,topped with
a layer of 60mm
terrazzo/vinyl floor finsh
Glass handrail at a height of
900mm
Passivent Soundscoop
620mm x 320mm x 1200mm
natural ventilation system
Passivent Soundscoop
620mm x 320mm x 1200mm
natural ventilation system
Glass handrail at a height of
900mm
Carlson - Aluminium Clad
Timber windows internal
softwood finish with an
external recycled aluminium
finish
Ground Floor Level
0
First Floor Level
3760
Parapet Level
7620
Parapet 2 Ventilation
Stacks
9120
123456789
34603003760100
376038601500
50mm sand blinding, DPM
layer,100mm EPS rigid foam
insulation,cast in-situ
structural raft foundation in
accordance with BS EN
1992-1-2:2004, 100mm
structural screed, topped with
60mm terrazzo/vinyl floor
finish
Insitu pocket foundation to
provide a fixed base
connection to the precast
concrete column in
accordance with BS EN
1992-1-2: 2004
Passivent Soundscoop
620mm x 320mm x 1200mm
natural ventilation system
Passivent Soundscoop
620mm x 320mm x 1200mm
natural ventilation system
200mm Exposed Polished
Finish Blockwork Partition
Wall 60min Fire Rating
762
300mm Square Primary
Structure Precast Concrete
Column in accordance with
BS En 1992-1-2:2004
900mm height protective
railing around roof to allow
safe access to roof area
Reynaers Eco System 50
insulated and Ventilated
Windows
Roof mounted Monocrystaline
Photovoltaic Panels
900mm height protective
railing around roof to allow
safe access to roof area
200mm Solid Wall Precast
Concrete Panels to BS EN
1992-1-2:2004, 200mm EPS
Rigid Foam Insulation, 8mm
External Render
2145
2145
2933
A-AA-A
A-A
A-A
B-B
B-B
B-BB-B
Scale
LECTURER
Drawn by
Date
Project number
Institute of Technology Carlow
BSc. (Hons) in Architectural Technology
Year 4 2013-2014
As indicated
Section Views
2
Studio Thesis: School Building of
the Future
02-May-2014
Edel Fox
Noel Dunne, Sujana Sudhir
& Dan O' Sullivan
GATPSV107
1 : 150
Long Section A-A1
1 : 150
Short Section A-A2
1 : 150
Long Section B-B3
1 : 150
Short Section B-B4
Specification:
Primary Structure – 300mm x 300mm reinforced
precast concrete columns to be placed at grid line
intersections as shown in the plan. 450mm x 500mm
edge beams and 600mm x 500mm inverted T beams
to be used to structurally support the flooring slabs.
Reinforcements to be in accordance with structural
engineers specifications and where possible to be
recycled steel.
Structural Foundations – Each primary structure
300mm x 300mm square precast concrete column to
be connected back to its own individual precast
concrete pocket foundation. Each precast concrete
column will vary in depth depending on the slope of
the ground beneath. The rest of the building is to be
structurally supported below by a reinforced raft
foundation. Steel reinforcements to be in
accordance with engineers specifications. The raft
foundation is to be wrapped around the precast
concrete columns.
Ground Floor Build Up – 50mm sand blinding to be
placed onto the ground, a layer of DPM is to be
lapped and sealed and placed above the sand
blinding, 100mm Expanded Polystyrene (EPS) rigid
foam insulation to create a continuous barrier which
will eliminate cold bridges around the foundation.
Then a structural raft foundation is to be put in place
with reinforcements to be in accordance with
engineer’s specifications, and the cast in situ
concrete to be in accordance with BS EN 1992-1-
2:2004. Followed with a layer of 100mm structural
screed topping, finished with either a layer of 60mm
terrazzo floor finish or a vinyl floor finish depending
on the room use.
Intermediate Floor Build Up – The main structure
of the floor is made up of 200mm precast concrete
hollowcore flooring slabs in accordance with BS EN
1992-1-2:2004. This is followed by a layer of 100mm
structural screed which casts the rebars into place
tying the hollowcore flooring slabs back to the
precast concrete edge beams. The floor is finished
with either a layer of 60mm terrazzo floor finish or a
vinyl floor finish depending on the room use.
Roof Build Up – The main structure of the roof is
made up of 200mm precast concrete hollowcore
slabs in accordance with BS EN 1992-1-2:2004. This
is followed by a layer of 100mm structural screed
which casts the rebars into place tying the hollowcore
flooring slabs back to the precast concrete edge
beams. This is followed by a vapour control layer
applied directly to the structural screed. Followed by
a layer of 150mm Expanded Polystyrene (EPS) rigid
foam insulation, to eliminate cold bridges along the
roof deck. Applied directly to the insulation is a
waterproofing membrane to stop water penetration.
The roof is finished with a layer of single ply EDPM
waterproofing membrane.
External Wall Build Up – From Exterior: 8mm
external render finish applied directly onto mesh
reinforcement, mesh reinforcement to apply render
finish to, 12mm cement particle board fixed @ 600mm
c/c, 200mm x 100mm steel U-channels fixed back to
the precast concrete wall panels @ 600mm c/c put in
place to support the cement particle board, with
200mm expanded polystyrene (EPS) rigid foam
insulation in between, finished with 200mm solid wall
precast concrete panels in accordance with BS EN
1992-1-2:2004 with an exposed internal finish.
Internal Wall Build Up – Stud Partition: Double
layer of 12.5mm gyproc board fixed back to 75mm
steel c channels with 75mm mineral wool insulation in
between, finished with a double layer of gyproc board
with a minimum of a 60min Fire Rating.
Blockwork: 200mm Exposed Polished Finish
Blockwork Partition Wall with a minimum of a 60min
Fire Rating.
General Notes:
-All works to comply with current building regulations and code of practice.
-All works must be done to the satisfaction of the building control officer.
-All dimensions in mm unless otherwise noted.
-Drawings must not be scaled, written dimensions must be followed.
-Primary structure precast concrete columns to be placed on the intersection of grid
lines as shown.
- Primary structure precast concrete beams to span along gridlines and to be cast in
place with a precast concrete column above and below.
-External walls not placed along gridlines, walls to be placed to the outer face of the
precast concrete column unless otherwise stated.
-Internal walls of the sports hall to be placed in between the precast concrete columns
as indicated on the plan.
-Primary structure precast concrete columns and beams to be in accordance with BS
EN 1992-1-2:2004.
-Solid wall precast concrete panels to be in accordance with BS EN 1992-1-2:2004.
-Precast concrete for lift shaft and stair shaft to comply with BS EN 1992-1-2:2004.
-Lift and stair shaft to be 60min fire proof including access doors.
-All escape fire doors to be 60min fire rated and fitted with automatic closers.
-Floor finish to be non-slip vinyl flooring and terrazzo flooring.
-Entrance area to have a minimum level landing within 1800mm of entrance door.
Curtain Walling Specification:
Curtain Wall CW 50
-Manufacturer: Reynaers Ltd
-Product reference: Curtain Wall CW 50 Standard
/Curtain Wall CW 50-FP EW 30
/Curtain Wall CW 50-FP EW 60 /Curtain Wall CW
50- HL /Curtain Wall CW 50-RA
-Internal framing member: Extruded aluminium
- Finish: Anodized /Polyester powder coated
- Colour: White
-External cover cap: Extruded aluminium
- Finish: Anodized /Polyester powder coated
- Colour: White
-Windows: Fixed light (CW50-FP) /Glazed in windows
- Configuration: Horizontal pivot /Parallel opener
/Side hung /Tilt and turn /Top hung
-Glazing: Insulating glass units /Single glazed panes
-Glazing system: Dry glazed gasket
Window Specification:
Windows – Aluminium – Clad Timber – Manufacturer - Carlson
-Glass – Double glazing with low E glass – argon filled- thermal
conductivity 1.0 W/m²k
Toughened safety glass for windows installed below
800mm above ground level
-Frame – Internal: Softwood thermal conductivity 0.13 W/m²k in
accordance with ISO 10077-2:2003
External: Recycled aluminium
-Overall U-value of 1.35W/m²k achieving an A rating
-Manufactured to comply with BS 644:2012
-Weather performance must be tested in accordance with BS
6375-1
-Security performance must be tested to BS EN 1627-1630
Door Specification:
Doors – System – Reynaers CS 86 – HI Highly Energy
Efficient
Glass - Double glazing with low E glass – argon filled-
thermal conductivity 1.0 W/m²k
Toughened safety glass for glass panes installed
below 800mm above ground level
Frame – Aluminium inward opening flush door 68mm
Vent – 76mm
U-Value – 1.35W/m²k achieving an A rating
Thermal insulation must be tested in accordance with EN
ISO 10077-2
Acoustic performance must be tested in accordance with
EN ISO 140-3, EN ISO 717-1
Burglar resistance must be tested in accordance with NEN
5096-ENV1627
Solar Shading Specifications:
-Colt shadovoltaic solar shading system
with integrated photovoltaic cells into the
glass louvres
-Manufacturer: Colt
-Carrier system 4
-Metal frame coating in a weatherproof
white paint
-Glass to span in lengths of 1000mm
-Glass to span in widths of 600mm
-Angle of rotation 0-85°
Controls:
-Electronically operated via actuators
-SolTronic controls to be used
Aircool Ventilators Specifications:
-Manufacturer: Passivent
-Frame and external weather lourves:
extruded aluminium, with ABS thermal break
-Insect screen 4mm black polypropylene
-Internal cover grille: extruded aluminium
-Size: 1200mm x 1200mm x 180mm
-White polyester coated
-Class 1 fire rating in accordance with BS 476:
Part 7: 1987
-Weather performance in accordance with BS
EN 13030: 2001
-Air leakage performance in accordance with
BS 6375: Part 1: 1989
-Controls: 24V modulating actuators, control
sensors to be put in place to consider
temperature, CO₂, humidity and wind
(A-A)
(A-A) (B-B)
(B-B)