g	 Straight-Run Situations and Recommendations
g	 Installation Orientation Options for Various
Fluid Conditions
g	 Overcoming Limited Straight-Run and Flow
Obstructions Using Flow Conditioners
g	 Optimizing Accuracy and Repeatability Performance
Best Practices
Engineering Guide
Installation Recommendations for FCI Single-Point,
Thermal Dispersion Flow Meters
Optimizing Flow Meter Installation Ensures
Performance and Instrument Accuracy
All flow meter technologies have recommended installation and
engineering practices to ensure they meet their published specifications
and for optimal performance, accuracy and repeatability. Flow meter
users are frequently challenged with wide variations in their actual
field conditions and installation constraints that are much different
from the ideal conditions under which their flow meter was calibrated.
In fact, the most common installation constraint for most all flow
meter installations is inadequate straight-run. Flow meter users expect
their flow meter suppliers to provide engineering recommendations
and solutions to overcome real world application conditions to obtain
expected flow meter performance to specifications. This guide provides
recommended engineering practices with diagrams and specifications
for straight-run, installation orientation and depths, as well as use
of flow conditioners as an engineering solution for FCI single-point,
thermal dispersion flow meters.
Use FCI’s Free AVAL Tool for Proper Sizing
and Instrument Selection
FCI’s exclusive AVAL software tool is designed to make proper sizing
and selection of thermal dispersion flow meters simple and effective.
AVAL is always available and accessible by visiting
FCI’s website at www.fluidcomponents.com
and clicking on the AVAL icon.
Since process parameters, fluid compositions and installation
constraints can limit ideal performance, FCI AVAL software will
ensure you are fully aware of process conditions that can potentially
produce installed uncertainty. AVAL application evaluation software
is a proprietary FCI service designed from years of fluid testing
and installation experience. Using AVAL software, FCI models an
installation with straight run variations and obstructions. When a
complete evaluation is performed, an output report clearly defines
expected “installed” accuracy or offers recommendations for
improvement. FCI relates laboratory calibrations to true installed field
performance. The configuration software matches specific process
conditions and makes appropriate configuration recommendations for
each flow meter application.
FCI Offers Multiple Solutions to Limited
Straight-Run Conditions
Straight-run is one of the most significant variables to consider in your flow meter installation to ensure accurate and repeatable flow measurement.
Inadequate straight-run or the presence of flow disrupters are the most common real world constraints to proper flow meter installation.
Figure 1 provides recommendations and engineering practices for commonly found conditions and line sizes to ensure an installation supports the
meter’s published specifications. When possible, installing the flow meter within these recommendations will assure proper performance with the
least installed cost. Figure 2 shows samples of the effects on flow meter accuracy of obstructions.
Recognizing the straight-runs specified in Figure 1 are not always possible, FCI offers four solutions which can be applied by themselves or in
combination to overcome installation constraints.
	 g	Vortab®
Flow Conditioners to Develop Flow Profile and Negate Obstructions with up to 70% Reduction in Straight-Run Needed
	 g	 Customized Calibration Set-ups which Simulate the Actual Field Installation Conditions
	 g	 In-situ Field Calibration Service and Instrument Adjustment
	 g	 Multiple Sense Point Flow Meters
Figure 1: Straight Run Recommendations
Default Recommendation for Required Straight-runs with Undefined Obstructions
Pipe Size	 Upstream	 Downstream
< 6 inches [150 mm]	 20 x Pipe ID	 10 x Pipe ID
≥ 6 inches [150 mm]	 15 x Pipe ID	 7.5 x Pipe ID
with Vortab flow conditioner	 6 x Pipe ID	 2 x Pipe ID
Recommendation for 45˚ or 90˚ Elbows in Plane
Pipe Size	 Upstream	 Downstream
< 6 inches [150 mm]	 15 x Pipe ID	 7.5 x Pipe ID
≥ 6 inches [150 mm]	 10 x Pipe ID	 5 x Pipe ID
with Vortab flow conditioner	 6 x Pipe ID	 1 x Pipe ID
Recommendation for 45˚ or 90˚ Elbows OUT of Plane (Swirl Effect)
Pipe Size	 Upstream	 Downstream
< 6 inches [150 mm]	 20 x Pipe ID	 10 x Pipe ID
≥ 6 inches [150 mm]	 15 x Pipe ID	 5 x Pipe ID
with Vortab flow conditioner	 6 x Pipe ID	 2 x Pipe ID
Recommendation for Flow Controlling Valves Upstream or Downstream
Pipe Size	 Upstream	 Downstream
< 6 inches [150 mm]	 20 x Pipe ID	 10 x Pipe ID
≥ 6 inches [150 mm]	 15 x Pipe ID	 5 x Pipe ID
with Vortab flow conditioner	 9 x Pipe ID	 2 x Pipe ID
Recommendation for Pipe Adaptor Upstream or Downstream
Pipe Size	 Upstream	 Downstream
< 6 inches [150 mm]	 20 x Pipe ID	 10 x Pipe ID
≥ 6 inches [150 mm]	 15 x Pipe ID	 5 x Pipe ID
with Vortab flow conditioner	 9 x Pipe ID	 2 x Pipe ID
Recommendation for Pipe Reducers Upstream or Downstream
Pipe Size	 Upstream	 Downstream
< 6 inches [150 mm]	 15 x Pipe ID	 5 x Pipe ID
≥ 6 inches [150 mm]	 10 x Pipe ID	 3 x Pipe ID
with Vortab flow conditioner	 6 x Pipe ID	 1 x Pipe ID
Recommendations shown are for general reference only as actual application conditions can vary and multiple effects are possible.
FCI flow meter performance guarantees are only available following completed AVAL software-based application evaluations.
Contact your local FCI sales representative for a comprehensive evaluation.
Figure 2: Sample of Effects on Accuracy with Flow Obstructions Before and After Installation Point of Single-Point, Insertion Flow Meter
With Pipe ID < 6 inches [150 mm]
Distance From Flow Meter 19D 17D 15D 13D 11D 9D 7D 5D 3D 1D 1D 3D 5D 7D 9D
Obstruction Type:
90˚ Elbow 0% 0% <1% 1% 1% 2% 3% 4% 5% 5% 4% 3% 2% 1% 0%
Two Elbows (with 4D between them) 1% 1% 2% 2% 2% 3% 4% 6% 8% 9% 5% 4% 3% 2% 1%
Gate Valve 1% 2% 3% 4% 5% 6% 8% 10% 17% 20% 15% 13% 8% 3% 1%
With Pipe ID ≥ 6 inches [150 mm]
Distance From Flow Meter 19D 17D 15D 13D 11D 9D 7D 5D 3D 1D 1D 3D 5D 7D 9D
Obstruction Type:
90˚ Elbow 0% 0% 0% 0% 0% <1% 2% 3% 4% 5% 4% 2% <1% 0% 0%
Two Elbows (with 4D between them) 0% 0% <1% 2% 2% 2% 4% 5% 6% 8% 4% 3% <1% 0% 0%
Gate Valve 0% 0% <1% 2% 3% 4% 6% 8% 15% 20% 15% 5% <1% 0% 0%
Vortab Flow Conditioners
Reduce Straight-Run
In installations with inadequate
straight-run, Vortab flow conditioners
provide a solution that will ensure
flow meter performance in as little
as just 7 diameters upstream. This
patented technology is the flow
conditioner most recommended by
flow and process control experts to
eliminate the flow swirl and profile
distortions which adversely affect flow
meter measuring accuracy. Further,
because Vortab achieves results with
the least pressure drop, it actually
saves significantly on energy costs
over alternate techniques. FCI is the
only authorized supplier of Vortab
flow conditioners for use with thermal
dispersion technology flow meters.
Vortab are available as a spool-piece
meter run section, an insertable
sleeve and as a field weldable kit to
accommodate a variety of installation
needs.
Swirl Reduction Tabs – The swirl reduction tabs remove swirl by generating small vortices (swirls)
opposite to the main swirl. These cumulatively cancel the larger main swirl.
Profile Condition Tabs – Three sets of profile conditioning tabs produce vigorous cross-stream
mixing which rapidly mixes faster velocity regions with slower regions. This mixing quickly
produces a homogeneous (i.e., conditioned) velocity profile. In addition, uneven particulate
distributions or temperature profiles are made more uniform through this process.
Settling Distance – 3-4 pipe diameters of settling distance between the flow conditioner and flow
meter installation location are required to fully condition the flow stream.
X% : Application not recommended.
See Vortab discussions below on how to eliminate effect and improve accuracy.
See Vortab discussions below on how to eliminate effect and improve accuracy.
Figure 3: Vortab Flow Conditioning Removes Swirl and Creates Uniform Flow Profile
Figure 4: Pipe Installation Orientation Options for Insertion Style Flow Meters
Type Size Ball
Valve
ST98 1” NPT
ST50 ¾" NPT
FLUID COMPONENTS INTERNATIONAL solves flow and level measurement
applications for industrial process and plant applications using patented thermal
dispersion flow measurement technologies. With more than 40 years experience and
the world’s largest installed base of thermal dispersion instruments, you can count on
FCI to know your application and have proven solutions that will save you time and
expense. From off-the-shelf products to custom engineered products and systems,
FCI has the selection and an unequalled record of innovations to supply the optimal
product for your application. From single-point to multi-point flow meters, from
basic air flow to complex mixed, variable flare gas compositions, from water to the
harshest of chemicals, FCI products will deliver superior accuracy, repeatability and
long-term reliability at the lowest installed cost.
MT86/91 Series
ST50 Series
ST75 Series
ST98 Series
ST100 Series
Visit FCI online at www.FluidComponents.com
FCI World Headquarters
1755 La Costa Meadows Drive | San Marcos, California 92078 USA
Phone: 760-744-6950 Toll Free (US): 800-854-1993 Fax: 760-736-6250
FCI Europe
Persephonestraat 3-01 | 5047 TT Tilburg, The Netherlands
Phone: 31-13-5159989 Fax: 31-13-5799036
FCI Measurement and Control Technology (Beijing) Co., LTD
www.fluidcomponents.cn
Room 107, Xianfeng Building II, No.7 Kaituo Road, Shangdi IT Industry
Base, Haidian District | Beijing 100085, P. R. China
Phone: 86-10-82782381 Fax: 86-10-58851152
Doc. No. 02MK011528 B1012 2K

Contenu connexe

En vedette

Terry Jones: Using FluidDB for storage in location-aware software
Terry Jones: Using FluidDB for storage in location-aware softwareTerry Jones: Using FluidDB for storage in location-aware software
Terry Jones: Using FluidDB for storage in location-aware software
AGI Geocommunity
 
Innovations In Marketing With Technology 3 3009 Sbdc
Innovations In Marketing With Technology 3 3009 SbdcInnovations In Marketing With Technology 3 3009 Sbdc
Innovations In Marketing With Technology 3 3009 Sbdc
NetFlow
 
Facing interviews
Facing interviewsFacing interviews
Facing interviews
Tinku Kumar
 

En vedette (15)

Casa Campo Grande 2 Quartos
Casa Campo Grande 2 QuartosCasa Campo Grande 2 Quartos
Casa Campo Grande 2 Quartos
 
Remanufacturing reman stratégie actena
Remanufacturing reman stratégie actenaRemanufacturing reman stratégie actena
Remanufacturing reman stratégie actena
 
26feb 2015
26feb 201526feb 2015
26feb 2015
 
Terry Jones: Using FluidDB for storage in location-aware software
Terry Jones: Using FluidDB for storage in location-aware softwareTerry Jones: Using FluidDB for storage in location-aware software
Terry Jones: Using FluidDB for storage in location-aware software
 
Presentacio c. audiovisual
Presentacio c. audiovisualPresentacio c. audiovisual
Presentacio c. audiovisual
 
The Legitimacy Of A Property Title To Prevent Risks
The Legitimacy Of A Property Title To Prevent RisksThe Legitimacy Of A Property Title To Prevent Risks
The Legitimacy Of A Property Title To Prevent Risks
 
4 6 jan2014
4 6 jan20144 6 jan2014
4 6 jan2014
 
Filling the Gap Presentation
Filling the Gap PresentationFilling the Gap Presentation
Filling the Gap Presentation
 
Diptico divulgación
Diptico divulgación Diptico divulgación
Diptico divulgación
 
Isabel
IsabelIsabel
Isabel
 
Turbine flow meters for gas service from Hoffer
Turbine flow meters for gas service from HofferTurbine flow meters for gas service from Hoffer
Turbine flow meters for gas service from Hoffer
 
Innovations In Marketing With Technology 3 3009 Sbdc
Innovations In Marketing With Technology 3 3009 SbdcInnovations In Marketing With Technology 3 3009 Sbdc
Innovations In Marketing With Technology 3 3009 Sbdc
 
Thermal dispersion switch for flow, level, interface, or temperature
Thermal dispersion switch for flow, level, interface, or temperatureThermal dispersion switch for flow, level, interface, or temperature
Thermal dispersion switch for flow, level, interface, or temperature
 
Facing interviews
Facing interviewsFacing interviews
Facing interviews
 
Interview process
Interview processInterview process
Interview process
 

Plus de Flow-Tech, Inc.

Plus de Flow-Tech, Inc. (18)

Bently Nevada 3500 System Datasheet
Bently Nevada 3500 System DatasheetBently Nevada 3500 System Datasheet
Bently Nevada 3500 System Datasheet
 
Brooks Instrument Series GF40 Installation and Operation Manual
Brooks Instrument Series GF40 Installation and Operation ManualBrooks Instrument Series GF40 Installation and Operation Manual
Brooks Instrument Series GF40 Installation and Operation Manual
 
Solving Critical Process Applications for the Water and Wastewater Industry
Solving Critical Process Applications for the Water and Wastewater IndustrySolving Critical Process Applications for the Water and Wastewater Industry
Solving Critical Process Applications for the Water and Wastewater Industry
 
Campus & District BTU Energy Metering
Campus & District BTU Energy MeteringCampus & District BTU Energy Metering
Campus & District BTU Energy Metering
 
Fired Heater and Combustion eBook
Fired Heater and Combustion eBookFired Heater and Combustion eBook
Fired Heater and Combustion eBook
 
New Class of MFCs with Embedded Flow Diagnostics
New Class of MFCs with Embedded Flow DiagnosticsNew Class of MFCs with Embedded Flow Diagnostics
New Class of MFCs with Embedded Flow Diagnostics
 
Drager PointGard 2000 Series Gas Detection System
Drager PointGard 2000 Series Gas Detection SystemDrager PointGard 2000 Series Gas Detection System
Drager PointGard 2000 Series Gas Detection System
 
GE Advanced Modular Calibrator for Process Measurement Instruments
GE Advanced Modular Calibrator for Process Measurement InstrumentsGE Advanced Modular Calibrator for Process Measurement Instruments
GE Advanced Modular Calibrator for Process Measurement Instruments
 
Measuring Compressed Air Flow
Measuring Compressed Air FlowMeasuring Compressed Air Flow
Measuring Compressed Air Flow
 
Improve Process Control Security Using Annunciators as Watchers
Improve Process Control Security Using Annunciators as WatchersImprove Process Control Security Using Annunciators as Watchers
Improve Process Control Security Using Annunciators as Watchers
 
The Wafer Cone Flowmeter
The Wafer Cone FlowmeterThe Wafer Cone Flowmeter
The Wafer Cone Flowmeter
 
Reduce Unplanned Outages and Improve Profitability with Asset Condition Monit...
Reduce Unplanned Outages and Improve Profitability with Asset Condition Monit...Reduce Unplanned Outages and Improve Profitability with Asset Condition Monit...
Reduce Unplanned Outages and Improve Profitability with Asset Condition Monit...
 
List of Detectable Gasses and Vapors by CAS-Number 2015
List of Detectable Gasses and Vapors by CAS-Number 2015List of Detectable Gasses and Vapors by CAS-Number 2015
List of Detectable Gasses and Vapors by CAS-Number 2015
 
McCrometer V Cone Flowmeter Installation, Operations, Maintenace
McCrometer V Cone Flowmeter Installation, Operations, MaintenaceMcCrometer V Cone Flowmeter Installation, Operations, Maintenace
McCrometer V Cone Flowmeter Installation, Operations, Maintenace
 
Multivariable Transmitter for Mass Flow Measurement
Multivariable Transmitter for Mass Flow MeasurementMultivariable Transmitter for Mass Flow Measurement
Multivariable Transmitter for Mass Flow Measurement
 
Electrical Ground Rules Part 2
Electrical Ground Rules Part 2Electrical Ground Rules Part 2
Electrical Ground Rules Part 2
 
Liquid Vaporizer Systems
Liquid Vaporizer SystemsLiquid Vaporizer Systems
Liquid Vaporizer Systems
 
Arc Flash as it Relates to AC Drives
Arc Flash as it Relates to AC DrivesArc Flash as it Relates to AC Drives
Arc Flash as it Relates to AC Drives
 

Dernier

Top Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoor
Top Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoorTop Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoor
Top Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoor
dharasingh5698
 
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak HamilCara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Kandungan 087776558899
 
notes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.pptnotes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.ppt
MsecMca
 

Dernier (20)

Unleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leapUnleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leap
 
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
 
Top Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoor
Top Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoorTop Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoor
Top Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoor
 
Online banking management system project.pdf
Online banking management system project.pdfOnline banking management system project.pdf
Online banking management system project.pdf
 
Thermal Engineering Unit - I & II . ppt
Thermal Engineering  Unit - I & II . pptThermal Engineering  Unit - I & II . ppt
Thermal Engineering Unit - I & II . ppt
 
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak HamilCara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
 
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - V
 
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performance
 
notes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.pptnotes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.ppt
 
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
 
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
 
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
 
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
 
Unit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfUnit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdf
 
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
 
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced LoadsFEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.ppt
 

Single-Point, Thermal Dispersion Flow Meters: Best Practices Engineering Guide

  • 1. g Straight-Run Situations and Recommendations g Installation Orientation Options for Various Fluid Conditions g Overcoming Limited Straight-Run and Flow Obstructions Using Flow Conditioners g Optimizing Accuracy and Repeatability Performance Best Practices Engineering Guide Installation Recommendations for FCI Single-Point, Thermal Dispersion Flow Meters Optimizing Flow Meter Installation Ensures Performance and Instrument Accuracy All flow meter technologies have recommended installation and engineering practices to ensure they meet their published specifications and for optimal performance, accuracy and repeatability. Flow meter users are frequently challenged with wide variations in their actual field conditions and installation constraints that are much different from the ideal conditions under which their flow meter was calibrated. In fact, the most common installation constraint for most all flow meter installations is inadequate straight-run. Flow meter users expect their flow meter suppliers to provide engineering recommendations and solutions to overcome real world application conditions to obtain expected flow meter performance to specifications. This guide provides recommended engineering practices with diagrams and specifications for straight-run, installation orientation and depths, as well as use of flow conditioners as an engineering solution for FCI single-point, thermal dispersion flow meters. Use FCI’s Free AVAL Tool for Proper Sizing and Instrument Selection FCI’s exclusive AVAL software tool is designed to make proper sizing and selection of thermal dispersion flow meters simple and effective. AVAL is always available and accessible by visiting FCI’s website at www.fluidcomponents.com and clicking on the AVAL icon. Since process parameters, fluid compositions and installation constraints can limit ideal performance, FCI AVAL software will ensure you are fully aware of process conditions that can potentially produce installed uncertainty. AVAL application evaluation software is a proprietary FCI service designed from years of fluid testing and installation experience. Using AVAL software, FCI models an installation with straight run variations and obstructions. When a complete evaluation is performed, an output report clearly defines expected “installed” accuracy or offers recommendations for improvement. FCI relates laboratory calibrations to true installed field performance. The configuration software matches specific process conditions and makes appropriate configuration recommendations for each flow meter application.
  • 2. FCI Offers Multiple Solutions to Limited Straight-Run Conditions Straight-run is one of the most significant variables to consider in your flow meter installation to ensure accurate and repeatable flow measurement. Inadequate straight-run or the presence of flow disrupters are the most common real world constraints to proper flow meter installation. Figure 1 provides recommendations and engineering practices for commonly found conditions and line sizes to ensure an installation supports the meter’s published specifications. When possible, installing the flow meter within these recommendations will assure proper performance with the least installed cost. Figure 2 shows samples of the effects on flow meter accuracy of obstructions. Recognizing the straight-runs specified in Figure 1 are not always possible, FCI offers four solutions which can be applied by themselves or in combination to overcome installation constraints. g Vortab® Flow Conditioners to Develop Flow Profile and Negate Obstructions with up to 70% Reduction in Straight-Run Needed g Customized Calibration Set-ups which Simulate the Actual Field Installation Conditions g In-situ Field Calibration Service and Instrument Adjustment g Multiple Sense Point Flow Meters Figure 1: Straight Run Recommendations Default Recommendation for Required Straight-runs with Undefined Obstructions Pipe Size Upstream Downstream < 6 inches [150 mm] 20 x Pipe ID 10 x Pipe ID ≥ 6 inches [150 mm] 15 x Pipe ID 7.5 x Pipe ID with Vortab flow conditioner 6 x Pipe ID 2 x Pipe ID Recommendation for 45˚ or 90˚ Elbows in Plane Pipe Size Upstream Downstream < 6 inches [150 mm] 15 x Pipe ID 7.5 x Pipe ID ≥ 6 inches [150 mm] 10 x Pipe ID 5 x Pipe ID with Vortab flow conditioner 6 x Pipe ID 1 x Pipe ID Recommendation for 45˚ or 90˚ Elbows OUT of Plane (Swirl Effect) Pipe Size Upstream Downstream < 6 inches [150 mm] 20 x Pipe ID 10 x Pipe ID ≥ 6 inches [150 mm] 15 x Pipe ID 5 x Pipe ID with Vortab flow conditioner 6 x Pipe ID 2 x Pipe ID Recommendation for Flow Controlling Valves Upstream or Downstream Pipe Size Upstream Downstream < 6 inches [150 mm] 20 x Pipe ID 10 x Pipe ID ≥ 6 inches [150 mm] 15 x Pipe ID 5 x Pipe ID with Vortab flow conditioner 9 x Pipe ID 2 x Pipe ID Recommendation for Pipe Adaptor Upstream or Downstream Pipe Size Upstream Downstream < 6 inches [150 mm] 20 x Pipe ID 10 x Pipe ID ≥ 6 inches [150 mm] 15 x Pipe ID 5 x Pipe ID with Vortab flow conditioner 9 x Pipe ID 2 x Pipe ID Recommendation for Pipe Reducers Upstream or Downstream Pipe Size Upstream Downstream < 6 inches [150 mm] 15 x Pipe ID 5 x Pipe ID ≥ 6 inches [150 mm] 10 x Pipe ID 3 x Pipe ID with Vortab flow conditioner 6 x Pipe ID 1 x Pipe ID Recommendations shown are for general reference only as actual application conditions can vary and multiple effects are possible. FCI flow meter performance guarantees are only available following completed AVAL software-based application evaluations. Contact your local FCI sales representative for a comprehensive evaluation.
  • 3. Figure 2: Sample of Effects on Accuracy with Flow Obstructions Before and After Installation Point of Single-Point, Insertion Flow Meter With Pipe ID < 6 inches [150 mm] Distance From Flow Meter 19D 17D 15D 13D 11D 9D 7D 5D 3D 1D 1D 3D 5D 7D 9D Obstruction Type: 90˚ Elbow 0% 0% <1% 1% 1% 2% 3% 4% 5% 5% 4% 3% 2% 1% 0% Two Elbows (with 4D between them) 1% 1% 2% 2% 2% 3% 4% 6% 8% 9% 5% 4% 3% 2% 1% Gate Valve 1% 2% 3% 4% 5% 6% 8% 10% 17% 20% 15% 13% 8% 3% 1% With Pipe ID ≥ 6 inches [150 mm] Distance From Flow Meter 19D 17D 15D 13D 11D 9D 7D 5D 3D 1D 1D 3D 5D 7D 9D Obstruction Type: 90˚ Elbow 0% 0% 0% 0% 0% <1% 2% 3% 4% 5% 4% 2% <1% 0% 0% Two Elbows (with 4D between them) 0% 0% <1% 2% 2% 2% 4% 5% 6% 8% 4% 3% <1% 0% 0% Gate Valve 0% 0% <1% 2% 3% 4% 6% 8% 15% 20% 15% 5% <1% 0% 0% Vortab Flow Conditioners Reduce Straight-Run In installations with inadequate straight-run, Vortab flow conditioners provide a solution that will ensure flow meter performance in as little as just 7 diameters upstream. This patented technology is the flow conditioner most recommended by flow and process control experts to eliminate the flow swirl and profile distortions which adversely affect flow meter measuring accuracy. Further, because Vortab achieves results with the least pressure drop, it actually saves significantly on energy costs over alternate techniques. FCI is the only authorized supplier of Vortab flow conditioners for use with thermal dispersion technology flow meters. Vortab are available as a spool-piece meter run section, an insertable sleeve and as a field weldable kit to accommodate a variety of installation needs. Swirl Reduction Tabs – The swirl reduction tabs remove swirl by generating small vortices (swirls) opposite to the main swirl. These cumulatively cancel the larger main swirl. Profile Condition Tabs – Three sets of profile conditioning tabs produce vigorous cross-stream mixing which rapidly mixes faster velocity regions with slower regions. This mixing quickly produces a homogeneous (i.e., conditioned) velocity profile. In addition, uneven particulate distributions or temperature profiles are made more uniform through this process. Settling Distance – 3-4 pipe diameters of settling distance between the flow conditioner and flow meter installation location are required to fully condition the flow stream. X% : Application not recommended. See Vortab discussions below on how to eliminate effect and improve accuracy. See Vortab discussions below on how to eliminate effect and improve accuracy. Figure 3: Vortab Flow Conditioning Removes Swirl and Creates Uniform Flow Profile
  • 4. Figure 4: Pipe Installation Orientation Options for Insertion Style Flow Meters Type Size Ball Valve ST98 1” NPT ST50 ¾" NPT FLUID COMPONENTS INTERNATIONAL solves flow and level measurement applications for industrial process and plant applications using patented thermal dispersion flow measurement technologies. With more than 40 years experience and the world’s largest installed base of thermal dispersion instruments, you can count on FCI to know your application and have proven solutions that will save you time and expense. From off-the-shelf products to custom engineered products and systems, FCI has the selection and an unequalled record of innovations to supply the optimal product for your application. From single-point to multi-point flow meters, from basic air flow to complex mixed, variable flare gas compositions, from water to the harshest of chemicals, FCI products will deliver superior accuracy, repeatability and long-term reliability at the lowest installed cost. MT86/91 Series ST50 Series ST75 Series ST98 Series ST100 Series Visit FCI online at www.FluidComponents.com FCI World Headquarters 1755 La Costa Meadows Drive | San Marcos, California 92078 USA Phone: 760-744-6950 Toll Free (US): 800-854-1993 Fax: 760-736-6250 FCI Europe Persephonestraat 3-01 | 5047 TT Tilburg, The Netherlands Phone: 31-13-5159989 Fax: 31-13-5799036 FCI Measurement and Control Technology (Beijing) Co., LTD www.fluidcomponents.cn Room 107, Xianfeng Building II, No.7 Kaituo Road, Shangdi IT Industry Base, Haidian District | Beijing 100085, P. R. China Phone: 86-10-82782381 Fax: 86-10-58851152 Doc. No. 02MK011528 B1012 2K