CAPACITANCE ROD TYPE LEVEL TRANSMITTER
(Suitable for DM water applications)
Our Company is actively engaged in presenting a broad spectrum of Top Mounted Capacitance
Rod type level transmitters for DM water applications. These are designed by making use of
Top Quality Material of reputed brands of Electrical & Electronics Components with latest &
inventive techniques as well as thoroughly inspection done by our people with latest ones.
Technical Specs :
Model (DM-RCLT)
Frequecy of operation :5 to 15 kHz.
Probe Material :Stainless Steel rod Teflon insulated along with Outer pipe.
Process connection : As per Customer requirements.
Total Height : Maximum 3500mm
Calibration points : from Top process connection to 60mm and bottom.
Power supply : 24 VDC
Output : 4 to 20 mA.
Span & Zero adjustment : Push buttons
Accuracy : + 0.5 %
Enclosure : Cast aluminium flameproof
Cable Size :3 core, PVC cable 1.5 Metre long.
Working Procedure:
Can be connectable with directly to PLC (or) any Digital level controller. As per the tank height,
sensor might calibrated and gives signal 4mA(LOW) to 20MA (High). In-between, you can
operate valves & pumps ie. 4mA, 8mA,12mA,16mA & 20mA nor on tank capacity information
display in ltrs as per provided output relays on PLC’s (or) Controllers.
Suggestion:
Technical support provided at the time of installation if required.
Contact:
INSTRUMENTS
(Process Automation & Control Solutions - Mechanical & Instruments Supplier)
H #. 1-10-28/30/1, Opp. MRR High School, Main Road, Kushaiguda - Cherlapally Road,
Nagarjuna Nagar, Kushaiguda, ECIL Post, Hyderabad-62, TS.
@: hemainstruments@gmail.com ; sales@hemainstruments.com
www.hemainstruments.com
M: +91 98486 49035 | +91 81218 89111
_________________________________________________________________________________________________________________________________
Quality improvement comes via simplification of design, manufacturing with safety features… layouts, processes and procedures

Contenu connexe

En vedette

درس تطبيقي رجل الغراب
درس تطبيقي رجل الغرابدرس تطبيقي رجل الغراب
درس تطبيقي رجل الغرابarhab far
 
Comisiones por retiro de efectivo
Comisiones por retiro de efectivo Comisiones por retiro de efectivo
Comisiones por retiro de efectivo Argentarium, SRL
 
Tacuarembó nohabilitados arte 2016
Tacuarembó nohabilitados arte 2016Tacuarembó nohabilitados arte 2016
Tacuarembó nohabilitados arte 2016Celeste Funes
 

En vedette (6)

درس تطبيقي رجل الغراب
درس تطبيقي رجل الغرابدرس تطبيقي رجل الغراب
درس تطبيقي رجل الغراب
 
Filtros
FiltrosFiltros
Filtros
 
Comisiones por retiro de efectivo
Comisiones por retiro de efectivo Comisiones por retiro de efectivo
Comisiones por retiro de efectivo
 
Tacuarembó nohabilitados arte 2016
Tacuarembó nohabilitados arte 2016Tacuarembó nohabilitados arte 2016
Tacuarembó nohabilitados arte 2016
 
NHTMC feb 12Presention
NHTMC feb 12PresentionNHTMC feb 12Presention
NHTMC feb 12Presention
 
Bg Advise1
Bg Advise1Bg Advise1
Bg Advise1
 

Rod type level transmitter catalogue

  • 1. CAPACITANCE ROD TYPE LEVEL TRANSMITTER (Suitable for DM water applications) Our Company is actively engaged in presenting a broad spectrum of Top Mounted Capacitance Rod type level transmitters for DM water applications. These are designed by making use of Top Quality Material of reputed brands of Electrical & Electronics Components with latest & inventive techniques as well as thoroughly inspection done by our people with latest ones. Technical Specs : Model (DM-RCLT) Frequecy of operation :5 to 15 kHz. Probe Material :Stainless Steel rod Teflon insulated along with Outer pipe. Process connection : As per Customer requirements. Total Height : Maximum 3500mm Calibration points : from Top process connection to 60mm and bottom. Power supply : 24 VDC Output : 4 to 20 mA. Span & Zero adjustment : Push buttons Accuracy : + 0.5 % Enclosure : Cast aluminium flameproof Cable Size :3 core, PVC cable 1.5 Metre long. Working Procedure: Can be connectable with directly to PLC (or) any Digital level controller. As per the tank height, sensor might calibrated and gives signal 4mA(LOW) to 20MA (High). In-between, you can operate valves & pumps ie. 4mA, 8mA,12mA,16mA & 20mA nor on tank capacity information display in ltrs as per provided output relays on PLC’s (or) Controllers. Suggestion: Technical support provided at the time of installation if required. Contact: INSTRUMENTS (Process Automation & Control Solutions - Mechanical & Instruments Supplier) H #. 1-10-28/30/1, Opp. MRR High School, Main Road, Kushaiguda - Cherlapally Road, Nagarjuna Nagar, Kushaiguda, ECIL Post, Hyderabad-62, TS. @: hemainstruments@gmail.com ; sales@hemainstruments.com www.hemainstruments.com M: +91 98486 49035 | +91 81218 89111 _________________________________________________________________________________________________________________________________ Quality improvement comes via simplification of design, manufacturing with safety features… layouts, processes and procedures