SlideShare une entreprise Scribd logo
1  sur  39
GROUNDWATER DATALOGGER
LEVEL MEASUREMENT BASICS
2014 ©HydroG Resources Group Inc.
Dataloggers are now frequently used
for water level measurement by
hydrogeologists and technicians.
This course introduces some basic
concepts and methods for beginners.
• Introduce basic concepts1
• Review standard
protocols2
• Illustrate practical field
methods3
Course Outline
Knowledge Base
We are assuming you are familiar with :
• common terms such as pressure; water
level measurement; elevation; aquifer;
unconfined; water table; etc.
• concepts of quality control and quality
assurance.
For simplicity all our examples deal with the
water table in an unconfined aquifer.
BASIC DATALOGGER CONCEPTS
What Is A Datalogger?
“Datalogger” is the term used in this
course, however they are also known by a
variety of other terms (including pressure
sensors, transducers, etc).
Dataloggers are available in a wide variety
of makes and models with a large range of
capabilities and associated cost scale.
What Is A Datalogger?
Dataloggers allow automated water level
measurements to be obtained at rapid rates
and/or in remote locations. They improve
our capability to monitor water level.
To do this Dataloggers measure water or air
PRESSURE, record those measurements as
digital time series files, and, allows the files
to be retrieved as needed.
Why Measure Pressure?
The Datalogger measures pressure, but is
used to obtain water level measurements.
The pressure reading is used as an
INDIRECT measure of water level.
It is important to note that the Datalogger
pressure readings must be CONVERTED to
an equivalent water level measurement.
Why Measure Pressure?
• Water pressure increases with depth.
• Pressure values can be converted to an equivalent depth of water.
• However there are a number of practical factors to consider.
we want to measure the
pressure due to water column (PH20 )
water level
but atmospheric air pressure (Patm)
is also acting on the water column
therefore total pressure at this depth PT= PH20 + Patm
Datalogger Pressure Measurement
Some Dataloggers have a vent tube to the atmosphere which allow
“Gauge Pressure” measurements of PH2O directly.
Some Dataloggers are sealed units that measure Total (or “Absolute”)
Pressure (PT). In order to obtain PH2O you must also measure Patm (usually
with a separate Barologger) and subtract that value from your readings.
PH20
water level
Patm
PT
Vented Datalogger
Measures PH20 directly.
Non-vented Datalogger
Measures PT
Sensor is open to air pressure
Barologger
Measures Patm
Datalogger Construction Basics
• Two component groups to
consider:
1. The pressure sensor, and,
2. The internal electronics
(including battery).
• The pressure sensor has a
diaphragm, one side of
which is exposed to water.
• The diaphragm changes
shape as pressure changes. pressure to
be measured
diaphragm
electronics
(not shown)
Datalogger Construction Basics
• The changing shape also changes the electrical
resistance across the diaphragm – this provides a
range of voltage “signals” that corresponds to
equivalent pressures.
• For each measurement the internal electronics
provides voltage to the sensor, then converts the
returning “signal” to a pressure reading, and records
the data.
venting and
communication
cable
communication port
Datalogger Construction Example
This is a (very) old example
of a vented sensor.
Datalogger Construction Example
electronicspressure sensor
diaphragm
vent tube
Sensor disassembled
to show components
Datalogger Type Review
Vented Non-vented
Patm
PatmPH2O
Pconstant
PatmPH2O
diaphragm
atmospheric
pressure
“cancels out”
across diaphragm
PH2O measured
directly
sealed unit
measures PT
PH2O is calculated
STANDARD METHODS
Standard Method SOP’s
A few datalogger specific Standard Operating
Procedures do exist.
Two examples are:
• USGS
• ISO 2005
United States Geological Survey
Use of Submersible Pressure Transducers in
Water-resources Investigations, USGS
Techniques of Water- Resources Investigations
Book 8, Chapter A3 (2004).
Provides a detailed explanation of
theory, and, construction/operation of
Dataloggers.
Please refer to that publication for more
details.
ISO 2005
Reference: International Standard ISO/TR
23211, Hydrometry – Measuring the water
level in a well using automated pressure
transducer methods.
 Similar to USGS paper and methodology,
please refer to the publication for more
details.
Summary
• Detailed theoretical background information and
SOP’s exist, these deal with a wide variety of
instrument types and conditions.
• However for most practical applications using
modern commercially available complete
Datalogger units, some basic understanding and
common sense use should result in good data.
• We encourage you to develop a practical SOP for
your organization.
PRACTICAL FIELD METHODS
Try To Avoid These Situations!
(mistakes we have already made, or found, in the field)
confusion
(poor planning)
unanticipated conditions
(that were in fact predictable)
(more mistakes ….)
installations that really
don’t measure anything
(can you tell why?)
messy installations
(again, poor planning)
Datalogger Success
All of the commercially available Dataloggers that are
typically in use, vented or non-vented, can provide
accurate and valid water level data – provided they are
installed and used correctly.
Operator training is essential for success.
Basic Considerations
To ensure you are collecting good (accurate) data, you
should consider a number of factors when using a
Datalogger – including :
• Datalogger choice
• Datalogger use
• Datalogger installation
• Converting Datalogger readings to water levels
Datalogger Choice
• Type (Vented vs. Non-vented)
• Measurement range
• Rated accuracy
• Measurement frequency
• Installation method
• Communication method
• Battery life
• Construction material
• Reliability
• Durability
• User options
• Software
• Technical support
• Warranty
• Flexibility
• Special conditions
There are many factors to consider when choosing a
Datalogger for your project. Some of these factors include:
Datalogger Choice
The final choice of Datalogger will depend on your
project and organizational needs, specific
recommendations are beyond the scope of this course.
The key is to plan each Datalogger installation starting
with why you need it, what data you need to collect,
what conditions the Datalogger will encounter at the
well, how will it be installed, and, how it will be
maintained and downloaded.
Datalogger Use
Once you choose your Datalogger follow the
manufacturer’s instructions regarding
communication, programing and use. In addition you
should:
• Test each Datalogger before it goes into the field.
• Develop a QA/QC program that starts when you
install the Datalogger.
• Regularly maintain / download the Datalogger.
• Review your data – check for errors.
Datalogger Use
Remember you are using the Datalogger to calculate
equivalent water level measurements. So you need to
“calibrate” the measurement and conversion process.
• Obtain regular manual water level measurements to
compare to your Datalogger data.
• Check regularly to ensure the Datalogger is responding
correctly to water level change.
• Remember – no Datalogger will last forever, monitor
parameters that predict failure (DRIFT, battery levels,
other anomalies, etc.) before it happens so that you can
replace it in time.
Datalogger Installation Basics
The Datalogger is hung
(set) on a cable to a
specific depth in the well
below a reference
(measuring) point.
The depth setting should
be below water and
remain constant .
If needed, the Barologger
is set above the water.
Well Screen
Well casing
Top of well
(measuring point)
Water
Level
Cable
Datalogger
Barologger
(if needed)
Installation Considerations
• Depth to water and well construction (e.g. total well depth).
• Expected water level variation (e.g. avoid a dry Datalogger).
• Maximum pressure / depth (exceeding damages the sensor).
• Type of cable used (stainless, direct read, vented, etc.).
• How cable is secured at the top of the well.
• Need for Barologger to measure atmospheric pressure.
• Other equipment installed in well.
There are many factors to consider when installing
your Datalogger. Some of these factors include:
Some Installation Tips
• Vented Dataloggers need a Vented
communication cable, install according to
manufacturer’s instructions.
• Direct read cables can also be used for Non-
vented Dataloggers, again install according to
manufacture’s instructions.
• Many Non-vented Dataloggers are installed on
simple cables or lines. These need to be removed
(pulled) from the well at each download.
Our Preferred Method
held securely in place
lowered into well
to set depth
stainless
cable
stainless
swage
sleeves
stainless
hose clamp
stainless
quick
links
ready to install
Some Installation Tips
Please refer to our website for more details on
recommended cable materials and installation
methods for Non-Vented Dataloggers.
hydrogresources.com
CalculationsTop of well
(measuring point)
Water Level
Barologger
measures Patm
Datalogger
Vented
measures PH2O
Non-vented
measures PT
watercolumn(W)
Dataloggerdepthsetting(D)
First find W (length, in metres).
A Vented Datalogger may give you
depth of water directly (m or cm).
For a Non-vented Datalogger
subtract Patm from PT .
Programming your Datalogger to
read in depth of water (e.g. cm of
H2O) makes things easier.
Subtracting W from D gives a
depth to water from the top of the
well. Keeping D constant over time
becomes very important!
Data Accuracy
• The accuracy of your Datalogger will be much greater than the
accuracy of your installation depth setting measurement or
manual water levels (used to check the validity of your data)
• Manual water level measurements are generally ±1 cm
• Improving the accuracy of your depth setting measurement is one
of the most important methods to improve your data accuracy
• Avoid the tendency to determine the depth setting based on
Datalogger measurements, measure your depth setting!
• Datalogger depth setting (D) changes over time result in DRIFT
There are many factors that affect the accuracy of
your measurements. Some factors to consider:
Like everything – the care you take in your
Datalogger installation and use will be
reflected in the accuracy of your data.
Planning the installation, and recording as
much information as possible in the process,
helps immensely.
There is no substitute for common sense, so
adapt to your own situation, and good luck!
Response tests are
completed at two
wells at the same
time using separate
Dataloggers.
When you are trying
to do 10 things at
once…….
Some consistency
helps!
WE HOPE YOU ENJOYED THIS
COURSE – PLEASE ALSO SEE OUR
COURSES ON ELIMINATING
DATALOGGER ERRORS
2014 ©HydroG Resources Group Inc.

Contenu connexe

Tendances

Ground Geophysical Survey
Ground Geophysical SurveyGround Geophysical Survey
Ground Geophysical SurveyOmary Issa
 
Groundwater Management
Groundwater ManagementGroundwater Management
Groundwater ManagementSean Carroll
 
Ground water resource evaluation
Ground water resource evaluationGround water resource evaluation
Ground water resource evaluationRenel Alucilja
 
Água subterrânea infiltração
Água subterrânea   infiltraçãoÁgua subterrânea   infiltração
Água subterrânea infiltraçãomarciotecsoma
 
Groundwater Data Requirement and Analysis
Groundwater Data Requirement and AnalysisGroundwater Data Requirement and Analysis
Groundwater Data Requirement and AnalysisC. P. Kumar
 
"Deepwater Managed Pressure Drilling and Well Drillability, Efficiency and Pr...
"Deepwater Managed Pressure Drilling and Well Drillability, Efficiency and Pr..."Deepwater Managed Pressure Drilling and Well Drillability, Efficiency and Pr...
"Deepwater Managed Pressure Drilling and Well Drillability, Efficiency and Pr...Society of Petroleum Engineers
 
radio isotope in ground water study
radio isotope in ground water studyradio isotope in ground water study
radio isotope in ground water studypreethi durairaj
 
Presentation-Formation_Evaluation by well logging _ENI.pdf
Presentation-Formation_Evaluation by well logging _ENI.pdfPresentation-Formation_Evaluation by well logging _ENI.pdf
Presentation-Formation_Evaluation by well logging _ENI.pdfssuser00e626
 
Reservoir sedimentation & its control
Reservoir sedimentation & its controlReservoir sedimentation & its control
Reservoir sedimentation & its controlZahinRana
 
Hydrology cycle and ground water (GT&AG)
Hydrology cycle and ground water (GT&AG)Hydrology cycle and ground water (GT&AG)
Hydrology cycle and ground water (GT&AG)Er.Navazhushen Patel
 
2 d and 3d land seismic data acquisition and seismic data processing
2 d and 3d land seismic data acquisition and seismic data processing2 d and 3d land seismic data acquisition and seismic data processing
2 d and 3d land seismic data acquisition and seismic data processingAli Mahroug
 
Hidráulica apresentação geral
Hidráulica   apresentação geralHidráulica   apresentação geral
Hidráulica apresentação geralGiovanna Ortiz
 
Modelling of Seawater Intrusion
Modelling of Seawater IntrusionModelling of Seawater Intrusion
Modelling of Seawater IntrusionC. P. Kumar
 
Reservoir Inundation Mapping, Dam Break and Breach Assessments with MIKE FLOOD
Reservoir Inundation Mapping, Dam Break and Breach Assessments with MIKE FLOODReservoir Inundation Mapping, Dam Break and Breach Assessments with MIKE FLOOD
Reservoir Inundation Mapping, Dam Break and Breach Assessments with MIKE FLOODStephen Flood
 

Tendances (20)

Ground Geophysical Survey
Ground Geophysical SurveyGround Geophysical Survey
Ground Geophysical Survey
 
Groundwater Management
Groundwater ManagementGroundwater Management
Groundwater Management
 
Ground water resource evaluation
Ground water resource evaluationGround water resource evaluation
Ground water resource evaluation
 
Água subterrânea infiltração
Água subterrânea   infiltraçãoÁgua subterrânea   infiltração
Água subterrânea infiltração
 
Procedure for conducting pumping tests
Procedure for conducting pumping testsProcedure for conducting pumping tests
Procedure for conducting pumping tests
 
Groundwater Data Requirement and Analysis
Groundwater Data Requirement and AnalysisGroundwater Data Requirement and Analysis
Groundwater Data Requirement and Analysis
 
"Deepwater Managed Pressure Drilling and Well Drillability, Efficiency and Pr...
"Deepwater Managed Pressure Drilling and Well Drillability, Efficiency and Pr..."Deepwater Managed Pressure Drilling and Well Drillability, Efficiency and Pr...
"Deepwater Managed Pressure Drilling and Well Drillability, Efficiency and Pr...
 
05 groundwater flow equations
05 groundwater flow equations05 groundwater flow equations
05 groundwater flow equations
 
radio isotope in ground water study
radio isotope in ground water studyradio isotope in ground water study
radio isotope in ground water study
 
Presentation-Formation_Evaluation by well logging _ENI.pdf
Presentation-Formation_Evaluation by well logging _ENI.pdfPresentation-Formation_Evaluation by well logging _ENI.pdf
Presentation-Formation_Evaluation by well logging _ENI.pdf
 
Reservoir sedimentation & its control
Reservoir sedimentation & its controlReservoir sedimentation & its control
Reservoir sedimentation & its control
 
Well logging notes
Well logging notesWell logging notes
Well logging notes
 
Hydrology cycle and ground water (GT&AG)
Hydrology cycle and ground water (GT&AG)Hydrology cycle and ground water (GT&AG)
Hydrology cycle and ground water (GT&AG)
 
subsea
subseasubsea
subsea
 
2 d and 3d land seismic data acquisition and seismic data processing
2 d and 3d land seismic data acquisition and seismic data processing2 d and 3d land seismic data acquisition and seismic data processing
2 d and 3d land seismic data acquisition and seismic data processing
 
RQD
RQDRQD
RQD
 
Chapter 5 Fetter Ground water flow to wells
Chapter 5 Fetter Ground water flow to wellsChapter 5 Fetter Ground water flow to wells
Chapter 5 Fetter Ground water flow to wells
 
Hidráulica apresentação geral
Hidráulica   apresentação geralHidráulica   apresentação geral
Hidráulica apresentação geral
 
Modelling of Seawater Intrusion
Modelling of Seawater IntrusionModelling of Seawater Intrusion
Modelling of Seawater Intrusion
 
Reservoir Inundation Mapping, Dam Break and Breach Assessments with MIKE FLOOD
Reservoir Inundation Mapping, Dam Break and Breach Assessments with MIKE FLOODReservoir Inundation Mapping, Dam Break and Breach Assessments with MIKE FLOOD
Reservoir Inundation Mapping, Dam Break and Breach Assessments with MIKE FLOOD
 

Similaire à Basic Datalogger Water Level Measurement

Datalogger error introductory course
Datalogger error introductory courseDatalogger error introductory course
Datalogger error introductory courseHydroG Resources
 
Download-manuals-ground water-manual-gw-volume4referencemanualgeo-hydrology
 Download-manuals-ground water-manual-gw-volume4referencemanualgeo-hydrology Download-manuals-ground water-manual-gw-volume4referencemanualgeo-hydrology
Download-manuals-ground water-manual-gw-volume4referencemanualgeo-hydrologyhydrologyproject001
 
A Beginner’s Guide: How to Use Flow Data Logger for Efficient Monitoring
A Beginner’s Guide: How to Use Flow Data Logger for Efficient MonitoringA Beginner’s Guide: How to Use Flow Data Logger for Efficient Monitoring
A Beginner’s Guide: How to Use Flow Data Logger for Efficient MonitoringInfyiot Solutions
 
MARIA NDAGO PROJECT.pptx
MARIA NDAGO  PROJECT.pptxMARIA NDAGO  PROJECT.pptx
MARIA NDAGO PROJECT.pptxSungaleliYuen
 
Download-manuals-surface water-manual-sw-volume4fieldmanualhydrometrypartviii
 Download-manuals-surface water-manual-sw-volume4fieldmanualhydrometrypartviii Download-manuals-surface water-manual-sw-volume4fieldmanualhydrometrypartviii
Download-manuals-surface water-manual-sw-volume4fieldmanualhydrometrypartviiihydrologyproject001
 
Flow assurance and surge analysis
Flow assurance and surge analysisFlow assurance and surge analysis
Flow assurance and surge analysisJohn Kingsley
 
Dwlr, float type with shaft encoder (sw)
Dwlr, float type with shaft encoder (sw)Dwlr, float type with shaft encoder (sw)
Dwlr, float type with shaft encoder (sw)hydrologyproject0
 
Final Project Report
Final Project ReportFinal Project Report
Final Project ReportTeam 02
 
Onset Data Logger Basics
Onset Data Logger BasicsOnset Data Logger Basics
Onset Data Logger BasicsMetrics GmbH
 
Qualitrol | Vault Monitoring
Qualitrol | Vault MonitoringQualitrol | Vault Monitoring
Qualitrol | Vault MonitoringSean Wallace
 
Instrumentation Lab - Final.pptx
Instrumentation Lab - Final.pptxInstrumentation Lab - Final.pptx
Instrumentation Lab - Final.pptxKannanRamaraj1
 
Real Time Water Quality Monitoring and Alert Systems, Applications using OPEX...
Real Time Water Quality Monitoring and Alert Systems, Applications using OPEX...Real Time Water Quality Monitoring and Alert Systems, Applications using OPEX...
Real Time Water Quality Monitoring and Alert Systems, Applications using OPEX...RekaNext Capital
 
SysEng Water India 2011 conference presentation
SysEng Water India 2011 conference presentationSysEng Water India 2011 conference presentation
SysEng Water India 2011 conference presentationRekaNext Capital
 
How to Calibrate a Pressure Gauge with a Pressure Comparator or Calibrator We...
How to Calibrate a Pressure Gauge with a Pressure Comparator or Calibrator We...How to Calibrate a Pressure Gauge with a Pressure Comparator or Calibrator We...
How to Calibrate a Pressure Gauge with a Pressure Comparator or Calibrator We...Transcat
 

Similaire à Basic Datalogger Water Level Measurement (20)

Datalogger error introductory course
Datalogger error introductory courseDatalogger error introductory course
Datalogger error introductory course
 
Data logger
Data loggerData logger
Data logger
 
Download-manuals-ground water-manual-gw-volume4referencemanualgeo-hydrology
 Download-manuals-ground water-manual-gw-volume4referencemanualgeo-hydrology Download-manuals-ground water-manual-gw-volume4referencemanualgeo-hydrology
Download-manuals-ground water-manual-gw-volume4referencemanualgeo-hydrology
 
A Beginner’s Guide: How to Use Flow Data Logger for Efficient Monitoring
A Beginner’s Guide: How to Use Flow Data Logger for Efficient MonitoringA Beginner’s Guide: How to Use Flow Data Logger for Efficient Monitoring
A Beginner’s Guide: How to Use Flow Data Logger for Efficient Monitoring
 
MARIA NDAGO PROJECT.pptx
MARIA NDAGO  PROJECT.pptxMARIA NDAGO  PROJECT.pptx
MARIA NDAGO PROJECT.pptx
 
Dwlr, pressure type (sw)
Dwlr, pressure type (sw)Dwlr, pressure type (sw)
Dwlr, pressure type (sw)
 
Dwlr, bubbler type (sw)
Dwlr, bubbler type (sw)Dwlr, bubbler type (sw)
Dwlr, bubbler type (sw)
 
sir G 2
sir G 2sir G 2
sir G 2
 
Final report
Final reportFinal report
Final report
 
Download-manuals-surface water-manual-sw-volume4fieldmanualhydrometrypartviii
 Download-manuals-surface water-manual-sw-volume4fieldmanualhydrometrypartviii Download-manuals-surface water-manual-sw-volume4fieldmanualhydrometrypartviii
Download-manuals-surface water-manual-sw-volume4fieldmanualhydrometrypartviii
 
Flow assurance and surge analysis
Flow assurance and surge analysisFlow assurance and surge analysis
Flow assurance and surge analysis
 
Dwlr, float type with shaft encoder (sw)
Dwlr, float type with shaft encoder (sw)Dwlr, float type with shaft encoder (sw)
Dwlr, float type with shaft encoder (sw)
 
Wet compressed air flow meters vp flow-scope dp
Wet compressed air flow meters   vp flow-scope dpWet compressed air flow meters   vp flow-scope dp
Wet compressed air flow meters vp flow-scope dp
 
Final Project Report
Final Project ReportFinal Project Report
Final Project Report
 
Onset Data Logger Basics
Onset Data Logger BasicsOnset Data Logger Basics
Onset Data Logger Basics
 
Qualitrol | Vault Monitoring
Qualitrol | Vault MonitoringQualitrol | Vault Monitoring
Qualitrol | Vault Monitoring
 
Instrumentation Lab - Final.pptx
Instrumentation Lab - Final.pptxInstrumentation Lab - Final.pptx
Instrumentation Lab - Final.pptx
 
Real Time Water Quality Monitoring and Alert Systems, Applications using OPEX...
Real Time Water Quality Monitoring and Alert Systems, Applications using OPEX...Real Time Water Quality Monitoring and Alert Systems, Applications using OPEX...
Real Time Water Quality Monitoring and Alert Systems, Applications using OPEX...
 
SysEng Water India 2011 conference presentation
SysEng Water India 2011 conference presentationSysEng Water India 2011 conference presentation
SysEng Water India 2011 conference presentation
 
How to Calibrate a Pressure Gauge with a Pressure Comparator or Calibrator We...
How to Calibrate a Pressure Gauge with a Pressure Comparator or Calibrator We...How to Calibrate a Pressure Gauge with a Pressure Comparator or Calibrator We...
How to Calibrate a Pressure Gauge with a Pressure Comparator or Calibrator We...
 

Dernier

Bun (KitWorks Team Study 노별마루 발표 2024.4.22)
Bun (KitWorks Team Study 노별마루 발표 2024.4.22)Bun (KitWorks Team Study 노별마루 발표 2024.4.22)
Bun (KitWorks Team Study 노별마루 발표 2024.4.22)Wonjun Hwang
 
Leverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage Cost
Leverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage CostLeverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage Cost
Leverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage CostZilliz
 
"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr Bagan"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr BaganFwdays
 
Beyond Boundaries: Leveraging No-Code Solutions for Industry Innovation
Beyond Boundaries: Leveraging No-Code Solutions for Industry InnovationBeyond Boundaries: Leveraging No-Code Solutions for Industry Innovation
Beyond Boundaries: Leveraging No-Code Solutions for Industry InnovationSafe Software
 
Vector Databases 101 - An introduction to the world of Vector Databases
Vector Databases 101 - An introduction to the world of Vector DatabasesVector Databases 101 - An introduction to the world of Vector Databases
Vector Databases 101 - An introduction to the world of Vector DatabasesZilliz
 
Dev Dives: Streamline document processing with UiPath Studio Web
Dev Dives: Streamline document processing with UiPath Studio WebDev Dives: Streamline document processing with UiPath Studio Web
Dev Dives: Streamline document processing with UiPath Studio WebUiPathCommunity
 
WordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your BrandWordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your Brandgvaughan
 
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024BookNet Canada
 
Anypoint Exchange: It’s Not Just a Repo!
Anypoint Exchange: It’s Not Just a Repo!Anypoint Exchange: It’s Not Just a Repo!
Anypoint Exchange: It’s Not Just a Repo!Manik S Magar
 
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Patryk Bandurski
 
Human Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsHuman Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsMark Billinghurst
 
Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024Enterprise Knowledge
 
Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Mattias Andersson
 
Unleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding ClubUnleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding ClubKalema Edgar
 
Unraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdfUnraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdfAlex Barbosa Coqueiro
 
"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek Schlawack
"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek Schlawack"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek Schlawack
"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek SchlawackFwdays
 
"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii SoldatenkoFwdays
 
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks..."LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...Fwdays
 
Powerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time ClashPowerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time Clashcharlottematthew16
 
What's New in Teams Calling, Meetings and Devices March 2024
What's New in Teams Calling, Meetings and Devices March 2024What's New in Teams Calling, Meetings and Devices March 2024
What's New in Teams Calling, Meetings and Devices March 2024Stephanie Beckett
 

Dernier (20)

Bun (KitWorks Team Study 노별마루 발표 2024.4.22)
Bun (KitWorks Team Study 노별마루 발표 2024.4.22)Bun (KitWorks Team Study 노별마루 발표 2024.4.22)
Bun (KitWorks Team Study 노별마루 발표 2024.4.22)
 
Leverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage Cost
Leverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage CostLeverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage Cost
Leverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage Cost
 
"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr Bagan"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr Bagan
 
Beyond Boundaries: Leveraging No-Code Solutions for Industry Innovation
Beyond Boundaries: Leveraging No-Code Solutions for Industry InnovationBeyond Boundaries: Leveraging No-Code Solutions for Industry Innovation
Beyond Boundaries: Leveraging No-Code Solutions for Industry Innovation
 
Vector Databases 101 - An introduction to the world of Vector Databases
Vector Databases 101 - An introduction to the world of Vector DatabasesVector Databases 101 - An introduction to the world of Vector Databases
Vector Databases 101 - An introduction to the world of Vector Databases
 
Dev Dives: Streamline document processing with UiPath Studio Web
Dev Dives: Streamline document processing with UiPath Studio WebDev Dives: Streamline document processing with UiPath Studio Web
Dev Dives: Streamline document processing with UiPath Studio Web
 
WordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your BrandWordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your Brand
 
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
 
Anypoint Exchange: It’s Not Just a Repo!
Anypoint Exchange: It’s Not Just a Repo!Anypoint Exchange: It’s Not Just a Repo!
Anypoint Exchange: It’s Not Just a Repo!
 
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
 
Human Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsHuman Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR Systems
 
Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024
 
Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?
 
Unleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding ClubUnleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding Club
 
Unraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdfUnraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdf
 
"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek Schlawack
"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek Schlawack"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek Schlawack
"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek Schlawack
 
"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko
 
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks..."LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
 
Powerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time ClashPowerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time Clash
 
What's New in Teams Calling, Meetings and Devices March 2024
What's New in Teams Calling, Meetings and Devices March 2024What's New in Teams Calling, Meetings and Devices March 2024
What's New in Teams Calling, Meetings and Devices March 2024
 

Basic Datalogger Water Level Measurement

  • 1. GROUNDWATER DATALOGGER LEVEL MEASUREMENT BASICS 2014 ©HydroG Resources Group Inc.
  • 2. Dataloggers are now frequently used for water level measurement by hydrogeologists and technicians. This course introduces some basic concepts and methods for beginners.
  • 3. • Introduce basic concepts1 • Review standard protocols2 • Illustrate practical field methods3 Course Outline
  • 4. Knowledge Base We are assuming you are familiar with : • common terms such as pressure; water level measurement; elevation; aquifer; unconfined; water table; etc. • concepts of quality control and quality assurance. For simplicity all our examples deal with the water table in an unconfined aquifer.
  • 6. What Is A Datalogger? “Datalogger” is the term used in this course, however they are also known by a variety of other terms (including pressure sensors, transducers, etc). Dataloggers are available in a wide variety of makes and models with a large range of capabilities and associated cost scale.
  • 7. What Is A Datalogger? Dataloggers allow automated water level measurements to be obtained at rapid rates and/or in remote locations. They improve our capability to monitor water level. To do this Dataloggers measure water or air PRESSURE, record those measurements as digital time series files, and, allows the files to be retrieved as needed.
  • 8. Why Measure Pressure? The Datalogger measures pressure, but is used to obtain water level measurements. The pressure reading is used as an INDIRECT measure of water level. It is important to note that the Datalogger pressure readings must be CONVERTED to an equivalent water level measurement.
  • 9. Why Measure Pressure? • Water pressure increases with depth. • Pressure values can be converted to an equivalent depth of water. • However there are a number of practical factors to consider. we want to measure the pressure due to water column (PH20 ) water level but atmospheric air pressure (Patm) is also acting on the water column therefore total pressure at this depth PT= PH20 + Patm
  • 10. Datalogger Pressure Measurement Some Dataloggers have a vent tube to the atmosphere which allow “Gauge Pressure” measurements of PH2O directly. Some Dataloggers are sealed units that measure Total (or “Absolute”) Pressure (PT). In order to obtain PH2O you must also measure Patm (usually with a separate Barologger) and subtract that value from your readings. PH20 water level Patm PT Vented Datalogger Measures PH20 directly. Non-vented Datalogger Measures PT Sensor is open to air pressure Barologger Measures Patm
  • 11. Datalogger Construction Basics • Two component groups to consider: 1. The pressure sensor, and, 2. The internal electronics (including battery). • The pressure sensor has a diaphragm, one side of which is exposed to water. • The diaphragm changes shape as pressure changes. pressure to be measured diaphragm electronics (not shown)
  • 12. Datalogger Construction Basics • The changing shape also changes the electrical resistance across the diaphragm – this provides a range of voltage “signals” that corresponds to equivalent pressures. • For each measurement the internal electronics provides voltage to the sensor, then converts the returning “signal” to a pressure reading, and records the data.
  • 13. venting and communication cable communication port Datalogger Construction Example This is a (very) old example of a vented sensor.
  • 14. Datalogger Construction Example electronicspressure sensor diaphragm vent tube Sensor disassembled to show components
  • 15. Datalogger Type Review Vented Non-vented Patm PatmPH2O Pconstant PatmPH2O diaphragm atmospheric pressure “cancels out” across diaphragm PH2O measured directly sealed unit measures PT PH2O is calculated
  • 17. Standard Method SOP’s A few datalogger specific Standard Operating Procedures do exist. Two examples are: • USGS • ISO 2005
  • 18. United States Geological Survey Use of Submersible Pressure Transducers in Water-resources Investigations, USGS Techniques of Water- Resources Investigations Book 8, Chapter A3 (2004). Provides a detailed explanation of theory, and, construction/operation of Dataloggers. Please refer to that publication for more details.
  • 19. ISO 2005 Reference: International Standard ISO/TR 23211, Hydrometry – Measuring the water level in a well using automated pressure transducer methods.  Similar to USGS paper and methodology, please refer to the publication for more details.
  • 20. Summary • Detailed theoretical background information and SOP’s exist, these deal with a wide variety of instrument types and conditions. • However for most practical applications using modern commercially available complete Datalogger units, some basic understanding and common sense use should result in good data. • We encourage you to develop a practical SOP for your organization.
  • 22. Try To Avoid These Situations! (mistakes we have already made, or found, in the field) confusion (poor planning) unanticipated conditions (that were in fact predictable)
  • 23. (more mistakes ….) installations that really don’t measure anything (can you tell why?) messy installations (again, poor planning)
  • 24. Datalogger Success All of the commercially available Dataloggers that are typically in use, vented or non-vented, can provide accurate and valid water level data – provided they are installed and used correctly. Operator training is essential for success.
  • 25. Basic Considerations To ensure you are collecting good (accurate) data, you should consider a number of factors when using a Datalogger – including : • Datalogger choice • Datalogger use • Datalogger installation • Converting Datalogger readings to water levels
  • 26. Datalogger Choice • Type (Vented vs. Non-vented) • Measurement range • Rated accuracy • Measurement frequency • Installation method • Communication method • Battery life • Construction material • Reliability • Durability • User options • Software • Technical support • Warranty • Flexibility • Special conditions There are many factors to consider when choosing a Datalogger for your project. Some of these factors include:
  • 27. Datalogger Choice The final choice of Datalogger will depend on your project and organizational needs, specific recommendations are beyond the scope of this course. The key is to plan each Datalogger installation starting with why you need it, what data you need to collect, what conditions the Datalogger will encounter at the well, how will it be installed, and, how it will be maintained and downloaded.
  • 28. Datalogger Use Once you choose your Datalogger follow the manufacturer’s instructions regarding communication, programing and use. In addition you should: • Test each Datalogger before it goes into the field. • Develop a QA/QC program that starts when you install the Datalogger. • Regularly maintain / download the Datalogger. • Review your data – check for errors.
  • 29. Datalogger Use Remember you are using the Datalogger to calculate equivalent water level measurements. So you need to “calibrate” the measurement and conversion process. • Obtain regular manual water level measurements to compare to your Datalogger data. • Check regularly to ensure the Datalogger is responding correctly to water level change. • Remember – no Datalogger will last forever, monitor parameters that predict failure (DRIFT, battery levels, other anomalies, etc.) before it happens so that you can replace it in time.
  • 30. Datalogger Installation Basics The Datalogger is hung (set) on a cable to a specific depth in the well below a reference (measuring) point. The depth setting should be below water and remain constant . If needed, the Barologger is set above the water. Well Screen Well casing Top of well (measuring point) Water Level Cable Datalogger Barologger (if needed)
  • 31. Installation Considerations • Depth to water and well construction (e.g. total well depth). • Expected water level variation (e.g. avoid a dry Datalogger). • Maximum pressure / depth (exceeding damages the sensor). • Type of cable used (stainless, direct read, vented, etc.). • How cable is secured at the top of the well. • Need for Barologger to measure atmospheric pressure. • Other equipment installed in well. There are many factors to consider when installing your Datalogger. Some of these factors include:
  • 32. Some Installation Tips • Vented Dataloggers need a Vented communication cable, install according to manufacturer’s instructions. • Direct read cables can also be used for Non- vented Dataloggers, again install according to manufacture’s instructions. • Many Non-vented Dataloggers are installed on simple cables or lines. These need to be removed (pulled) from the well at each download.
  • 33. Our Preferred Method held securely in place lowered into well to set depth stainless cable stainless swage sleeves stainless hose clamp stainless quick links ready to install
  • 34. Some Installation Tips Please refer to our website for more details on recommended cable materials and installation methods for Non-Vented Dataloggers. hydrogresources.com
  • 35. CalculationsTop of well (measuring point) Water Level Barologger measures Patm Datalogger Vented measures PH2O Non-vented measures PT watercolumn(W) Dataloggerdepthsetting(D) First find W (length, in metres). A Vented Datalogger may give you depth of water directly (m or cm). For a Non-vented Datalogger subtract Patm from PT . Programming your Datalogger to read in depth of water (e.g. cm of H2O) makes things easier. Subtracting W from D gives a depth to water from the top of the well. Keeping D constant over time becomes very important!
  • 36. Data Accuracy • The accuracy of your Datalogger will be much greater than the accuracy of your installation depth setting measurement or manual water levels (used to check the validity of your data) • Manual water level measurements are generally ±1 cm • Improving the accuracy of your depth setting measurement is one of the most important methods to improve your data accuracy • Avoid the tendency to determine the depth setting based on Datalogger measurements, measure your depth setting! • Datalogger depth setting (D) changes over time result in DRIFT There are many factors that affect the accuracy of your measurements. Some factors to consider:
  • 37. Like everything – the care you take in your Datalogger installation and use will be reflected in the accuracy of your data. Planning the installation, and recording as much information as possible in the process, helps immensely. There is no substitute for common sense, so adapt to your own situation, and good luck!
  • 38. Response tests are completed at two wells at the same time using separate Dataloggers. When you are trying to do 10 things at once……. Some consistency helps!
  • 39. WE HOPE YOU ENJOYED THIS COURSE – PLEASE ALSO SEE OUR COURSES ON ELIMINATING DATALOGGER ERRORS 2014 ©HydroG Resources Group Inc.

Notes de l'éditeur

  1. This template can be used as a starter file for presenting training materials in a group setting.SectionsRight-click on a slide to add sections. Sections can help to organize your slides or facilitate collaboration between multiple authors.NotesUse the Notes section for delivery notes or to provide additional details for the audience. View these notes in Presentation View during your presentation. Keep in mind the font size (important for accessibility, visibility, videotaping, and online production)Coordinated colors Pay particular attention to the graphs, charts, and text boxes.Consider that attendees will print in black and white or grayscale. Run a test print to make sure your colors work when printed in pure black and white and grayscale.Graphics, tables, and graphsKeep it simple: If possible, use consistent, non-distracting styles and colors.Label all graphs and tables.
  2. This is another option for an Overview slide.
  3. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  4. Use a section header for each of the topics, so there is a clear transition to the audience.
  5. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  6. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  7. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  8. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  9. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  10. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  11. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  12. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  13. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  14. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  15. Use a section header for each of the topics, so there is a clear transition to the audience.
  16. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  17. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  18. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  19. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  20. Use a section header for each of the topics, so there is a clear transition to the audience.
  21. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  22. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  23. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  24. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  25. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  26. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  27. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  28. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  29. Add slides to each topic section as necessary, including slides with tables, graphs, and images. See next section for sampletable, graph, image, and video layouts.
  30. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  31. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  32. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  33. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  34. Add slides to each topic section as necessary, including slides with tables, graphs, and images. See next section for sampletable, graph, image, and video layouts.
  35. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  36. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  37. What will the audience be able to do after this training is complete? Briefly describe each objective how the audiencewill benefit from this presentation.
  38. This template can be used as a starter file for presenting training materials in a group setting.SectionsRight-click on a slide to add sections. Sections can help to organize your slides or facilitate collaboration between multiple authors.NotesUse the Notes section for delivery notes or to provide additional details for the audience. View these notes in Presentation View during your presentation. Keep in mind the font size (important for accessibility, visibility, videotaping, and online production)Coordinated colors Pay particular attention to the graphs, charts, and text boxes.Consider that attendees will print in black and white or grayscale. Run a test print to make sure your colors work when printed in pure black and white and grayscale.Graphics, tables, and graphsKeep it simple: If possible, use consistent, non-distracting styles and colors.Label all graphs and tables.