1. Americas EMC Capabilities
Semi-anechoic Emissions Test
Frequency Range Electrical Power
Location Chambers Sites (OATs) Load
3m 10m 30m 3m 10m 30m Emissions Immunity DC 50Hz 60Hz
DC to
Boxborough, 20Hz to 40GHz 0-30V 100A 230V, 400V 120/208/240V 100A Chambers - 4T
MA █ █ █ 220GHz Up to 0-60V 50A 100A 277/480V 100A OATS – 2T
200 V/m
10kHz to
0-30 V, 120 A
20Hz to 18GHz 230 V, 50 A 120/208/240 V, 60 A
Duluth, GA █ █ 40GHz Up to
0-60 V, 50 A
400 V, 50 A 480V, 60 A
4T
50V, 100A
20 V/m
20Hz to
Grand Rapids, 20Hz to 18GHz 230 V, 16 A 120/208/240V 100A
MI █a 40GHz Up to
0-400 V, 0-50A
400 V, 16 A 277/480V 100A
1T
200 V/m
10KHZ- 120/208/240/480V;
Lake Forest, CA █ 9kHa-40GHz 2.7GHz 0-80VDC, 50A 230/400V, 50A 100/100/60/100A/per 4T
Up to 3 V/m phase.
10 kHz –
0-48V, 170 A
20Hz – 18GHz 0-240 V 120/208/480 V
Lexington, KY █ █ 40GHz Up to
0-80 V, 25 A
12 kVA/phase 100 A/phase
4T
0-400 V, 2 A
10 V/m
30 Hz to
90 - 240V 90 - 240V
30Hz to 18GHz
Louisville CO █ 40GHz Up to
0-50 V, 25A 100 A phase 100 A phase 1T
10 V/m
30 Hz –
480V, 208V,
20 Hz – 18 GHz 380V, 230V,
Menlo Park, CA █ █ 40 GHz Up to
48V, 60A
60A
120V, 4T
60A
20 V/m
10 kHz-
120/208/240/480V;
18GHz
Oakdale, MN █ █ █ █ 9kHz-40GHz
Up to
0-80VDC, 50A 230/380V, 100A 100/100/60/100A/per 8T
phase.
10 V/m
10KHZ-
120/208/240/480V;
4GHz
Plano, TX █ 9kHz-26GHz
Up to
0-50VDC, 50A 230/380V, 100A 100/100/60/100A/per 2T
phase.
10 V/m
Key █ Semi-anechoic chamber (emissions or immunity) █ Sheltered EMI site █ Open Area Test Site (OATS)
█ a. Grand Rapids also has a Reverb Chamber capable of immunity test levels up to 200 V/m +
2. Asia Pacific EMC Capabilities
Emissions or
Emissions Test
Immunity Frequency Range Electrical Power
Location Sites (OATs) Load
Chambers
3m 10m 30m 3m 10m 30m Emissions Immunity DC 50Hz 60Hz
Hong Kong █a █ 9k to 40 GHz 150k to 3GHz 24V
100-240V 100-240V
x2 13A 13A
800kg
Shanghai (ETL 12–72V 100–240V 100–240V
SEMKO) █ x2 9k to 26.5 GHz 150k to 3.2GHz
100A 25A 25A
█ x3 █ x3 █ x2
Kashima █ x2 █ 9k to 40 GHz 10k to 18GHz 100-240V/20kVA 100-240V/17kVA 10T
█ █ █
Matsuda █ x2 █ x5 █ x5 9k to 40GHz 10k to 18GHz 100-240V/15kVA 100-240V/15kVA 5T
80 to
Nagano █ █ x3 █ x3 9k to 40GHz
1000MHz
100-240V/6kVA 100-240V/6kVA 1T
Tochigi █ x3 █ x3 9k to 40GHz 100-240V/6kVA 100-240V/6kVA 5T
█ x2 48V 100-240V 100-240V
Shenzhen 9k to 18GHz 150k to 3GHz 3A 1T
16A 16A
Taiwan █ x2 9k to 40GHz 150k to 3GHz
12–48V 100–240V 110–230V
200kg
30A 25A 25A
2 shield rooms for conducted emissions, power disturbance, 0-240V single phase 0-120V
Guangzhou
magnetic emissions, and immunity tests 0-380V three phases single phase
Key █ Semi-anechoic chamber (emissions or immunity) █ Sheltered EMI site █ Open Area Test Site (OATS)
█ a. Full anechoic chamber used in Hong Kong for Immunity only
3. European EMC Capabilities
Semi-anechoic Emissions Test
Frequency Range Electrical Power
Chambers Sites (OATs)
Location Load
10 30 10 30
3m 3m Emissions Immunity DC 50Hz 60Hz
m m m m
0-300V
Italy 150kHz to 240V-22A 240V-22A
█a █ █ 9kHz to 18GHz
4.2GHz
16A,
320V-16A 320V-16A
1T
0-80V 30A
0-135V, 37A
20 Hz to 26.5 10 kHz to 3
Finland █ GHz GHz
0-120V, 13A 100 – 690V, 63A 4T
135 – 270V, 18A
0-440 V
9 kHz to 26.5 150 kHz to 4 0-150 V 0-440 V
Germany █ x2 █ █ GHz GHz 50 A 130 A per phase
110A 2T
per phase
20Hz to 10kHz to 0-54V 100-240V 100-240V
Sweden █ █ █ █ 40GHz 18GHz 200A 63A 16A
6T
20Hz to 20Hz to 0-100V 0-415V 0-110V
UK █ 5m █ █ 40GHz 18GHz 200A 150A per phase 16A
3T
Key █ Semi-anechoic chamber (emissions or immunity) █ Sheltered EMI site █ Open Area Test Site (OATS)
█ a. Italy: full anechoic chamber