Forskningskommunikasjon i tradisjonelle og sosiale medier universitetet i sta...
Jitender Singh Sr. Network Engg
1. Name : Jitender Singh Designation : Sr. Network Engineer
Company : NEC India Pvt. Ltd. Location : Gurgaon,Haryana
Project : Telenor Experience : 9.6Yrs
Skills : Transmission Planning
: Jiten.nec@gmail.com
: +919986129536
Passport No. : M0924734
OBJECTIVE
Seeking a challenging environment that encourages continuous learning and creativity, providing exposure to
new ideas that stimulate professional and personal growth, which can take full advantage of my technical and
interpersonal skills.
PROFILE SUMMARY
Professional with 9.6 years of experience Microwave Network Planning and Implementation, Project
Management on projects of Telenor, Reliance Jio, TTSL, Idea CellularLtd.,MTS & Reliance
Communication Ltd.
Currently Working as Corporate planner in NEC India Pvt Ltd. For Transmission Planning & Project
Rollout of Telewing project in Gurgaon, Haryana.
Worked as Sr.Network Engg. in NEC India Pvt. Ltd for Transmission Planning & Project Roll out of
Reliance jio project in Bangalore, Karnataka.
Executing Plan of Karnataka state 4G rollout for end to end connectivity.
Expertise in LB Creation on Pathloss Tool (PL5 and PL4). BOQ Preparation and SACFA.
Experienced in Implementation of Microwave links : NEC-SDH/PDH & iPaso100MB/200MBlink,
INTRACOM(IDR,ISR Links) and CERAGON-IP10 R1/R2 Links.
Experienced in Implementation of MUX(Fibcom Mux 6325-STM1, NEO Extension MUX & ALCATEL
MUX (1642, 1662, 1660)
Experience in Network designing on Map info, Global Mapper, Google Earth & Pathloss tool PL5 &
PL4.
PROFESSIONAL SYNOPSIS
Worked as Sr. Network Engineer in NEC India Pvt Ltd for Reliance Jio in Bangalore , Karnataka.
Worked as transmission Engineer in Nokia Siemens Network Pvt. Ltd. for TATA DOCOMO Project
in UP WEST.
Worked as project Coordinator in NEC India Pvt.Ltd for VIDEOCON Telecom Ltd,Idea cellular Ltd.
& TTSL Projectin Punjab Circle.
Worked as transmission Engineer in Arya Communication & Electronics services Pvt. Ltd. For
Reliance,TTSL & Shyam Telelink ltd. Projects in Rajasthan, Delhi/NCR,UP West, UP East, Haryana,
Himachal Pradesh, Kerala & Tamilnadu circles.
2. Worked as operation Engineer in Procall Pvt.Ltd for Airport, Embassy, BSES ,MCD & Air force etc.
in Delhi/NCR circle.
ACADAMIC PROFILE
Diploma in Electronics & Communication Engineering
College/University: Hindu Institute of Technology
Place: Sonipat, Haryana
Year of Passed: 2006
Board: State Board of Technical Education, Haryana.
PROFESSIONAL EXPERIENCE- 9.6 Years
Sr.Network Engineer –in NEC India Pvt. Ltd,Since Dec-2009 to till date
o Plan & Manage the entire MW network to ensure media availability for smooth Network Rollout.
o BOQ finalization, Network Health check & resolving issues related Pathloss 5.
o Transmission planning for whole network including LOS survey, Terrain survey and Link Engineering
with 99.999% availability.
o Frequency planning of MW access network and Interference analysis using Global Mapper and PATH
LOSS planning tool.
o MW Implementation & Team Management under Project pressure.
o Responsible for NW Planning(MW LOS Survey, Link budget, ring Optimization)
o Responsible for SACFA, Material dispatch, LOS issues.
o DCN Connectivity from Root NE to NMS Server.
o Testing of Ethernet in NEC ipaso ring
o Carrying planned Activity for traffic shifting for SDH Ring
Transmission Engineer – Deputed in Nokia Siemens Pvt. Ltd. from GTL Ltd.
- Since 26 May- 09 to 15 Dec-09
o Management of Vendors Team & Engineers for field implementation under project pressure
o Implementation of NEC Microwaves and Alcatel lucent MUXs for TATA DOCOMO Project.
o Escalation of infra issues to IP’s(Viom,Indus & TVI etc.) to resolve the same on appropriate time
o Providing the progress and status reports according to project requirements.
o Providing support for Integration of the newly commissioned MW sites.
o Ensuring Media loop & E1 termination is done properly for BTS integration.
o Providing Technical Assistance during MUX and MW I&C Implementation/NW Up gradation.
o Providing support for Customer to identify the faulty Equipments & transferring the same to R&R.
o Verify the work completed by NEC & Alcatel lucent for AT Sign off.
Engineer in ARYA Communication & Electronics Services Pvt. Ltd.
- Since 26 Nov 07 to 21 May 09
o Coordinate the Vendor team for MW I&C and MUX implementation under Project pressure.
o Installation, Commissioning & Alignment NEC Microwaves (SDH/PDH,1+1Hot Stand By etc.).
o Installation & commissioning of Alcatel Lucent MUXs(1642,1662, 1660)
o Escalation of infra issues to IP’s to resolve the same on appropriate time
o Responsible for LOS survey , MW I&C, E1 termination, NMS visibility and site integration
o Responsible for troubleshooting and providing on site assistance for seamless operations.
3. o Responsible for AT & Pre AT sign off.
Engineer in Procall Pvt. Ltd.
- Since 01 June 06 to 26 Nov 07
o Installation & Repairing of Motorola & Kenwood base sets at customer end
o Responsible for troubleshooting and providing technical supports to Engineers.
o Providing Training to Customer ( Airport, Embassy ,MCD Air force & BSES etc.).
o On the site rectify the issue & close the complaint with customer satisfactory Sign off.
MAIN ACHIEVEMENTS IN Nokia Siemens Networks & NEC
o Successfully MW I&C completed 2000+ MW HOPS in TATA DOCOMO Project – UP WEST Circle with
in Stipulated Time.
o Successfully MW I&C completed 1500+ MW HOPS in Videocon Telecom Ltd. Project – PUNJAB
Circle with in Stipulated Time.
o Successfully ipaso 100/200 Mb I&C completed 400+ MW HOPS and V4 LAN interface Card Up
gradation 600 hops in Idea Cellular Ltd. Project –PUNJAB Circle with in Stipulated Time.
SKILS ,TOOLS & SOFTWARE
o Knowledge in Ms office(Excel, Outlook, PPT, Word) and Internet & its applications
o Knowledge in SDH/PDH and 2G,3G & LTE technology.
o Knowledge in Ethernet protection( STP, RSTP, ERPS)
o Path loss Tool- Release the Link Budget.
o MapInfo – Link Connectivity, Design & LOS Survey.
o Global Mapper- Link Connectivity, Design & LOS Survey
o Google Earth- Microwave LOS Path
o Tool used- Path loss, MapInfo, Global mapper,Optical power meter, GPS, Compass, BER meter,
sentivity meter, Ethernet meter, E1 tester.
o Software used-PNMT,Pnmtj,RSL Collector,PMON,Alcatel(1642EM,1660,1662),Tellabs,LCT idr, LCT
Mbr,LCT isr, NetsetMan and Netconfigtool-NMS.
TRAINING & SEMINARS
o Training on NEC MUX – Neo Extension(2G)
o Training on NW/IP Planning/Allocation/Implementation
o Training on iPaso device(Ethernet, and IP Based)(3G)
o Training on NMS IP , NCT( NW configure tool) & Pnmsj.
Personal Details
• Father’s Name : Sh. Mandroop
• Mother’s Name : Smt. Santosh Devi
• Date of Birth : 2nd
April 1981
• Sex : Male
• Marital Status : Married
• Nationality : Indian
• Languages : English, Hindi
4. • Address : V.P.O. and tehsil khanpur kalan
Distt. Sonipat-Haryana.
Place:Sonipat (Jitender Singh)