SlideShare une entreprise Scribd logo
1  sur  52
Télécharger pour lire hors ligne
www.tuv.com
Page 2 of 52 Report No. 17044083 001
TEST REPORT
IEC 60598-2-2
Luminaires
Part 2: Particular requirements:
Section Two – Recessed luminaires
Report Number. ..............................: See the cover page
Date of issue ...................................: See the cover page
Total number of pages.................... See the cover page
Applicant’s name............................: See the cover page
Address ...........................................: See the cover page
Test specification:
Standard..........................................: EN 60598-2-2:2012 used in conjunction with
EN 60598-1: 2008 + A11: 2009
Test procedure ...............................: GS
Non-standard test method………..: N/A
Test Report Form No......................: IEC60598_2_2C
Test Report Form(s) Originator.....: Intertek Semko AB
Master TRF......................................: 2013-02
Copyright © 2013 Worldwide System for Conformity Testing and Certification of Electrotechnical
Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB
Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Test item description .....................: LED Down Light
Trade Mark ......................................: None
Factory.............................................: The same as appliant
Model/Type reference ....................: See model list.
Ratings ............................................: See model list.
www.tuv.com
Page 3 of 52 Report No. 17044083 001
Summary of testing:
Tests performed (name of test and test clause):
This report includes the following parts:
- All clauses of EN 60598-1: 2008+A11:2009 and EN
60598-2-2: 2012.
- Annex 5: European group differences and national
differences
- Annex 6: LED modules for general lighting —Safety
specifications EN 62031: 2008+A1: 2013.
- Annex 7: Photobiological safety of lamps and lamp
systems were evaluated according to standard EN
62471: 2008
Testing location:
Tests of EN 60598-2-2:2012
Guangzhou GRG Metrology &Test co., Ltd.
No.163Ping Yun Rd.West Of HuangPu
Ave.Guangzhou P.R.China
Tests for EN 62471: 2008
TÜV Rheinland (Guangdong) Ltd.
No.199 Kezhu Road, Guangzhou Science City
510663 Guangzhou, China
Summary of compliance with National Differences:
List of countries addressed: DE
DE=Germany
The product fulfils the requirements of EN 60598-1: 2008 + A11: 2009 and EN 60598-2-2: 2012.
www.tuv.com
Page 4 of 52 Report No. 17044083 001
TRF No. IEC60598_2_2C
Copy of marking plate
The artwork below may be only a draft. The use of certification marks on a product must be authorized by
the respective NCBs that own these marks.
Note: Other models have the similar marking label; only model name and parameter are different.
(labels of first column can be stick on body of LED Down light , labels of second column can be stick on
packing of LED Down light)
www.tuv.com
Page 5 of 52 Report No. 17044083 001
TRF No. IEC60598_2_2C
www.tuv.com
Page 6 of 52 Report No. 17044083 001
TRF No. IEC60598_2_2C
Test item particulars .............................................. :
Classification of installation and use ........................ : LED Recessed luminaire
Supply Connection ................................................... : Terminal Block
.................................................................................. :
.................................................................................. :
Possible test case verdicts:
- test case does not apply to the test object............. : N/A
- test object does meet the requirement................... : P (Pass)
- test object does not meet the requirement............. : F (Fail)
Testing..................................................................... :
Date of receipt of test item ....................................... : 2014-11-07
Date (s) of performance of tests............................... : 2014-11-17 to 2014-12-19
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.
Throughout this report a comma / point is used as the decimal separator.
Clause numbers between brackets refer to clauses in IEC 60598-1.
Remark
During heating test, fix the luminaire to a ceiling, a box as following cover the luminaire, a=0mm, b=c=0mm.
www.tuv.com
Page 7 of 52 Report No. 17044083 001
General product information:
Product: LED Recessed luminaire
Class II, IP20, ta=35C, luminaires not suitable for covering with thermally insulating material.
All models have the similar construction, only model name, dimensions and LED are different.
Full tests were conducted on model XH-HDLR-30W-X5, XH-CDLR-30W-X5, XH-HDLR-40W-X6, XH-CDLR-40W-X6, XH-CDLR-40W-X4 and XH-HDLR-30W-X3
except Photobiological safety.
Model list:
Model Input Models of
LED Driver
Output of LED
Driver
Power CCT LED quantity LED type Size Cut out
XH-HDLR-
30W-X5
AC 220-240V
50/60Hz
LF-
GIR030YX07
50A(Z)
27-40Vdc
750mA
30W 2700-6500K 60Pcs SMD5630 Φ230x80mm Φ195mm
XH-HDLR-
20W-X5
AC 220-240V
50/60Hz
LF-
GIR022YX05
40A(Z)
27-42Vdc
540mA
20W 2700-6500K 48Pcs SMD5630 Φ
190*H60mm
Φ160MM
XH-HDLR-
15W-X5
AC 220-240V
50/60Hz
LF-
GIR015YX03
80A(Z)
27-42Vdc
380mA
15W 2700-6500K 36 Pcs SMD5630 Φ
145mm*H60
mm
Φ125MM
XH-HDLR-
12W-X5
AC 220-240V
50/60Hz
LF-
GIR010YX02
50A(Z)
27-42Vdc
250mA
12W 2700-6500K 24 Pcs SMD5630 Φ
145mm*H60
mm
Φ125MM
XH-CDLR-
30W-X5
AC 220-240V
50/60Hz
LF-
GIR030YX07
50A(Z)
27-40Vdc
750mA
30W 2700-5000K 1 Pcs COB Φ230x80mm Φ195mm
XH-CDLR-
20W-X5
AC 220-240V
50/60Hz
LF-
GIR022YX05
40A(Z)
27-42Vdc
540mA
20W 2700-5000K 1 Pcs COB Φ
190*H60mm
Φ160MM
www.tuv.com
Page 8 of 52 Report No. 17044083 001
TRF No. IEC60598_2_2C
XH-CDLR-
15W-X5
AC 220-240V
50/60Hz
LF-
GIR015YX03
80A(Z)
27-42Vdc
380mA
15W 2700-5000K 1 Pcs COB Φ
145mm*H60
mm
Φ125MM
XH-CDLR-
12W-X5
AC 220-240V
50/60Hz
LF-
GIR010YX02
50A(Z)
27-42Vdc
250mA
12W 2700-5000K 1 Pcs COB Φ
145mm*H60
mm
Φ125MM
XH-HDLR-
40W-X6
AC 220-240V
50/60Hz
LF-
GIR040YX10
00A(Z)
27-42Vdc
1000mA
40W 2700-6500K 84Pcs SMD5630 Φ240x80mm Φ220mm
XH-HDLR-
30W-X6
AC 220-240V
50/60Hz
LF-
GIR030YX07
50A(Z)
27-40Vdc
750mA
30W 2700-6500K 60Pcs SMD5630 Φ240x80mm Φ220mm
XH-HDLR-
20W-X6
AC 220-240V
50/60Hz
LF-
GIR022YX05
40A(Z)
27-42Vdc
540mA
20W 2700-6500K 48Pcs SMD5630 Φ190x80mm Φ180mm
XH-HDLR-
15W-X6
AC 220-240V
50/60Hz
LF-
GIR015YX03
80A(Z)
27-42Vdc
380mA
15W 2700-6500K 36 Pcs SMD5630 Φ
166*H80mm
Φ150mm
XH-HDLR-
12W-X6
AC 220-240V
50/60Hz
LF-
GIR010YX02
50A(Z)
27-42Vdc
250mA
12W 2700-6500K 24 Pcs SMD5630 Φ130x70mm Φ120mm
XH-CDLR-
40W-X6
AC 220-240V
50/60Hz
LF-
GIR040YX10
00A(Z)
27-42Vdc
1000mA
40W 2700-5000K 1 Pcs COB Φ240x80mm Φ220mm
www.tuv.com
Page 9 of 52 Report No. 17044083 001
TRF No. IEC60598_2_2C
XH-CDLR-
30W-X6
AC 220-240V
50/60Hz
LF-
GIR030YX07
50A(Z)
27-40Vdc
750mA
30W 2700-5000K 1 Pcs COB Φ240x80mm Φ220mm
XH-CDLR-
20W-X6
AC 220-240V
50/60Hz
LF-
GIR022YX05
40A(Z)
27-42Vdc
540mA
20W 2700-5000K 1 Pcs COB Φ190x80mm Φ180mm
XH-CDLR-
15W-X6
AC 220-240V
50/60Hz
LF-
GIR015YX03
80A(Z)
27-42Vdc
380mA
15W 2700-5000K 1 Pcs COB Φ
166*H80mm
Φ150mm
XH-CDLR-
12W-X6
AC 220-240V
50/60Hz
LF-
GIR010YX02
50A(Z)
27-42Vdc
250mA
12W 2700-5000K 1 Pcs COB Φ130x70mm Φ120mm
XH-CDLR-
40W-X4
AC 220-240V
50/60Hz
LF-
GIR040YX10
00A(Z)
27-42Vdc
1000mA
40W 2700-5000K 1 Pcs COB Ф
180mm*H130
mm
Φ145mm
XH-CDLR-
30W-X4
AC 220-240V
50/60Hz
LF-
GIR030YX07
50A(Z)
27-40Vdc
750mA
30W 2700-5000K 1 Pcs COB Ф
142mm*H118
mm
Φ110mm
XH-CDLR-
20W-X4
AC 220-240V
50/60Hz
LF-
GIR022YX05
40A(Z)
27-42Vdc
540mA
20W 2700-5000K 1 Pcs COB Ф
142mm*H118
mm
Φ110mm
XH-CDLR-
15W-X4
AC 220-240V
50/60Hz
LF-
GIR015YX03
80A(Z)
27-42Vdc
380mA
15W 2700-5000K 1 Pcs COB Ф
119mm*H103
mm
Φ90mm
www.tuv.com
Page 10 of 52 Report No. 17044083 001
TRF No. IEC60598_2_2C
XH-CDLR-
12W-X4
AC 220-240V
50/60Hz
LF-
GIR010YX02
50A(Z)
27-42Vdc
250mA
12W 2700-5000K 1 Pcs COB Ф
113mm*H88
mm
Φ80mm
XH-HDLR-
30W-X3
AC 220-240V
50/60Hz
LF-
GIR030YX07
50A(Z)
27-40Vdc
750mA
30W 2700-6500K 60Pcs SMD5630 Ф
230mm*H48
mm
Φ200mm
XH-HDLR-
20W-X3
AC 220-240V
50/60Hz
LF-
GIR022YX05
40A(Z)
27-42Vdc
540mA
20W 2700-6500K 48Pcs SMD5630 Ф
190mm*H48
mm
Φ170mm
XH-HDLR-
15W-X3
AC 220-240V
50/60Hz
LF-
GIR015YX03
80A(Z)
27-42Vdc
380mA
15W 2700-6500K 36 Pcs SMD5630 Ф
180mm*H42
mm
Φ150mm
XH-HDLR-
12W-X3
AC 220-240V
50/60Hz
LF-
GIR010YX02
50A(Z)
27-42Vdc
250mA
12W 2700-6500K 24 Pcs SMD5630 Ф
140mm*H42
mm
Φ120mm
www.tuv.com
Page 11 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
2.3 (0) GENERAL TEST REQUIREMENTS P
2.3 (0.1) Information for luminaire design considered Standard
Yes No

2.3 (0.3) More sections applicable ........................................: Yes No 
2.5 (2) CLASSIFICATION P
2.5 (2.2) Type of protection ................................................ : Class II 
2.5 (2.3) Degree of protection............................................. : IP20 
2.5 (2.4) Luminaire suitable for direct mounting on normally
flammable surfaces .............................................. :
Yes No 
2.5 (2.5) Luminaire for normal use ..................................... : Yes No 
Luminaire for rough service ................................. : Yes No 
2.6 (3) MARKING P
2.6 (3.2) Mandatory markings P
Position of the marking P
Format of symbols/text See marking plate P
2.6 (3.3) Additional information P
Language of instructions English and German P
2.6 (3.3.1) Combination luminaires N/A
2.6 (3.3.2) Nominal frequency in Hz 50/60Hz P
2.6 (3.3.3) Operating temperature N/A
2.6 (3.3.4) Symbol or warning notice N/A
2.6 (3.3.5) Wiring diagram N/A
2.6 (3.3.6) Special conditions N/A
2.6 (3.3.7) Metal halide lamp luminaire – warning N/A
2.6 (3.3.8) Limitation for semi-luminaires N/A
2.6 (3.3.9) Power factor and supply current N/A
2.6 (3.3.10) Suitability for use indoors N/A
2.6 (3.3.11) Luminaires with remote control N/A
2.6 (3.3.12) Clip-mounted luminaire – warning N/A
www.tuv.com
Page 12 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
2.6 (3.3.13) Specifications of protective shields N/A
2.6 (3.3.14) Symbol for nature of supply N/A
2.6 (3.3.15) Rated current of socket outlet N/A
2.6 (3.3.16) Rough service luminaire N/A
2.6 (3.3.17) Mounting instruction for type Y, type Z and some
type X attachments
N/A
2.6 (3.3.18) Non-ordinary luminaires with PVC cable N/A
2.6 (3.3.19) Protective conductor current in instruction if
applicable
N/A
2.6 (3.3.20) Provided with information if not intended to be
mounted within arm’s reach
N/A
2.6 (3.4) Test with water 15s P
Test with hexane 15s P
Legible after test P
Label attached P
2.7 (4) CONSTRUCTION P
2.7 (4.2) Components replaceable without difficulty N/A
2.7 (4.3) Wireways smooth and free from sharp edges P
2.7 (4.4) Lampholders N/A
2.7 (4.4.1) Integral lampholder N/A
2.7 (4.4.2) Wiring connection N/A
2.7 (4.4.3) Lampholder for end-to-end mounting N/A
2.7 (4.4.4) Positioning N/A
- pressure test (N) ................................................ : N/A
After test the lampholder comply with relevant
standard sheets and show no damage
N/A
After test on single-capped lampholder the
lampholder have not moved from its position and
show no permanent deformation
N/A
- bending test (N) ................................................. : N/A
After test the lampholder have not moved from its
position and show no permanent deformation
N/A
www.tuv.com
Page 13 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
2.7 (4.4.5) Peak pulse voltage N/A
2.7 (4.4.6) Centre contact N/A
2.7 (4.4.7) Parts in rough service luminaires resistant to
tracking
N/A
2.7 (4.4.8) Lamp connectors N/A
2.7 (4.4.9) Caps and bases correctly used N/A
2.7 (4.5) Starter holders N/A
Starter holder in luminaires other than class II N/A
Starter holder class II construction N/A
2.7 (4.6) Terminal blocks N/A
Tails N/A
Unsecured blocks N/A
2.7 (4.7) Terminals and supply connections P
2.7 (4.7.1) Contact to metal parts P
2.7 (4.7.2) Test 8 mm live conductor P
Test 8 mm earth conductor N/A
2.7 (4.7.3) Terminals for supply conductors P
2.7 (4.7.3.1) Welded connections: N/A
- stranded or solid conductor N/A
- spot welding N/A
- welding between wires N/A
- Type Z attachment N/A
- mechanical test according to 15.8.2 N/A
- electrical test according to 15.9 N/A
- heat test according to 15.9.2.3 and 15.9.2.4 N/A
2.7 (4.7.4) Terminals other than supply connection P
2.7 (4.7.5) Heat-resistant wiring/sleeves N/A
2.7 (4.7.6) Multi-pole plug N/A
- test at 30 N N/A
2.7 (4.8) Switches: N/A
www.tuv.com
Page 14 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
- adequate rating N/A
- adequate fixing N/A
- polarized supply N/A
- compliance with 61058-1 for electronic switches N/A
2.7 (4.9) Insulating lining and sleeves N/A
2.7 (4.9.1) Retainement N/A
Method of fixing .................................................... : N/A
2.7 (4.9.2) Insulated linings and sleeves N/A
Resistant to a temperature > 20 C to the wire
temperature or
N/A
a) & c) Insulation resistance and electric strength N/A
b) Ageing test. Temperature (C) ......................... : N/A
2.7 (4.10) Insulation of Class II luminaires P
2.7 (4.10.1) No contact, mounting surface – accessible metal
parts – wiring of basic insulation
P
Safe installation fixed luminaires P
Capacitors and switches N/A
Interference suppression capacitors according to
IEC 60384-14
N/A
2.7 (4.10.2) Assembly gaps: P
- not coincidental N/A
- no straight access with test probe P
2.7 (4.10.3) Retainment of insulation: N/A
- fixed N/A
- unable to be replaced; luminaire inoperative N/A
- sleeves retained in position N/A
- lining in lampholder N/A
2.7 (4.11) Electrical connections P
2.7 (4.11.1) Contact pressure P
2.7 (4.11.2) Screws: N/A
- self-tapping screws N/A
www.tuv.com
Page 15 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
- thread-cutting screws N/A
2.7 (4.11.3) Screw locking: N/A
- spring washer N/A
- rivets N/A
2.7 (4.11.4) Material of current-carrying parts P
2.7 (4.11.5) No contact to wood or mounting surface P
2.7 (4.11.6) Electro-mechanical contact systems For connector P
2.7 (4.12) Mechanical connections and glands N/A
2.7 (4.12.1) Screws not made of soft metal P
Screws of insulating material N/A
Torque test: torque (Nm); part .............................. : Screw for fixing cord
anchorage: 0,5Nm for all
test models
P
Torque test: torque (Nm); part .............................. : Screw for fixing LED Module :
max.0,5Nm for all test models
P
Torque test: torque (Nm); part .............................. : Screw for fixing LED Cover:
Max.1,2Nm for all test
models
P
2.7 (4.12.2) Screws with diameter < 3 mm screwed into metal N/A
2.7 (4.12.4) Locked connections: N/A
- fixed arms; torque (Nm)...................................... : N/A
- lampholder; torque (Nm)..................................... : N/A
- push-button switches; torque 0,8 Nm................. : N/A
2.7 (4.12.5) Screwed glands; force (Nm) ................................. : N/A
2.7 (4.13) Mechanical strength P
2.7 (4.13.1) Impact tests: P
- fragile parts; energy (Nm)................................... : N/A
- other parts; energy (Nm) .................................... : 0,35 Nm for all test models P
1) live parts P
2) linings N/A
3) protection P
4) covers P
www.tuv.com
Page 16 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
2.7 (4.13.3) Straight test finger P
2.7 (4.13.4) Rough service luminaires N/A
- IP54 or higher N/A
a) fixed N/A
b) hand-held N/A
c) delivered with a stand N/A
d) for temporary installations and suitable for
mounting on a stand
N/A
2.7 (4.13.6) Tumbling barrel N/A
2.7 (4.14) Suspensions and adjusting devices P
2.7 (4.14.1) Mechanical load: P
A) four times the weight Max.1,3×4 =5,2 Kg for 1
hours
P
B) torque 2,5 Nm N/A
C) bracket arm; bending moment (Nm)................ : N/A
D) load track-mounted luminaires N/A
E) clip-mounted luminaires, glass-shelve.
Thickness (mm) ................................................... :
N/A
Metal rod. diameter (mm) .................................... : N/A
Fixed luminaire or independent control gear
without fixing devices
N/A
2.7 (4.14.2) Load to flexible cables N/A
Mass (kg) ............................................................. : N/A
Stress in conductors (N/mm²) .............................. : N/A
Mass (kg) of semi-luminaire ................................. : N/A
Bending moment (Nm) of semi-luminaire ............ : N/A
2.7 (4.14.3) Adjusting devices: P
- flexing test; number of cycles ............................. : 45 Cycles P
- strands broken P
- electric strength test afterwards P
2.7 (4.14.4) Telescopic tubes: cords not fixed to tube; no
strain on conductors
N/A
www.tuv.com
Page 17 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
2.7 (4.14.5) Guide pulleys N/A
2.7 (4.14.6) Strain on socket-outlets N/A
2.7 (4.15) Flammable materials: P
- glow-wire test 650 C For LED cover P
- spacing  30 mm N/A
- screen withstanding test of 13.3.1 N/A
- screen dimensions N/A
- no fiercely burning material P
- thermal protection N/A
- electronic circuits exempted N/A
2.7 (4.15.2) Luminaires made of thermoplastic material with lamp control gear N/A
a) construction N/A
b) temperature sensing control N/A
c) surface temperature N/A
2.7 (4.16) Luminaires for mounting on normally flammable surfaces P
No lamp control gear (compliance with Section 12) N/A
2.7 (4.16.1) Lamp control gear spacing: N/A
- spacing 35 mm N/A
- spacing 10 mm N/A
2.7 (4.16.2) Thermal protection: N/A
- in lamp control gear N/A
- external N/A
- fixed position N/A
- temperature marked lamp control gear N/A
2.7 (4.16.3) Design to satisfy the test of 12.6 (see 12.6) N/A
2.7 (4.17) Drain holes N/A
Clearance at least 5 mm N/A
2.7 (4.18) Resistance to corrosion: N/A
2.7 (4.18.1) - rust-resistance N/A
2.7 (4.18.2) - season cracking in copper N/A
www.tuv.com
Page 18 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
2.7 (4.18.3) - corrosion of aluminium N/A
2.7 (4.19) Ignitors compatible with ballast N/A
2.7 (4.20) Rough service vibration N/A
2.7 (4.21) Protective shield: N/A
2.7 (4.21.1) Shield fitted N/A
Shield of glass if tungsten halogen lamps N/A
2.7 (4.21.2) Particles from a shattering lamp not impair safety N/A
2.7 (4.21.3) No direct path N/A
2.7 (4.21.4) Impact test on shield N/A
Glow-wire test on lamp compartment N/A
2.7 (4.22) Attachments to lamps N/A
2.7 (4.23) Semi-luminaires comply Class II N/A
2.7 (4.24) UV radiation for tungsten halogen lamps and
metal halide lamps (Annex P)
N/A
2.7 (4.25) No sharp point or edges P
2.7 (4.26) Short-circuit protection: N/A
2.7 (4.26.1) Uninsulated accessible SELV parts N/A
2.7 (4.26.2) Short-circuit test N/A
2.7 (4.26.3) Test chain according to Figure 29 N/A
2.7 (4.27) Terminal blocks with integrated screwless earthing contacts tested according
Annex V
N/A
Pull test of terminal fixing (20 N) N/A
After test, resistance < 0,05  N/A
Pull test of mechanical connection (50 N) N/A
After test, resistance < 0,05  N/A
Voltage drop test, resistance < 0,05  N/A
2.8 (11) CREEPAGE DISTANCES AND CLEARANCES P
Working voltage (V) .............................................. : The whole luminaire consist
of approved LED driver and
accessible SELV LED
Module

www.tuv.com
Page 19 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
Voltage form Sinusoidal
Non-sinusoidal

PTI < 600 > 600 
Impulse withstand category (Normal category II)
(Category III Annex U)
Category II Category III 
Rated pulse voltage (kV) ...................................... : 
(1) Current-carrying parts of different polarity: cr
(mm); cl (mm) ....................................................... :
N/A
(2) Current-carrying parts and accessible parts: cr
(mm); cl (mm) ....................................................... :
N/A
(3) Parts becoming live due to breakdown of
basic insulation and metal parts:
cr (mm); cl (mm) ................................................... :
N/A
(4) Outer surface of cable where it is clamped and
metal parts: cr (mm); cl (mm)................................ :
N/A
(6) Current-carrying parts and supporting surface:
cr (mm); cl (mm) ................................................... :
N/A
2.9 (7) PROVISION FOR EARTHING N/A
2.9 (7.2.1
+ 7.2.3)
Accessible metal parts N/A
Metal parts in contact with supporting surface N/A
Resistance < 0,5  ............................................... : N/A
Self-tapping screws used N/A
Thread-forming screws N/A
Thread-forming screw used in a grove N/A
Earth makes contact first N/A
Terminal blocks with integrated screwless
earthing contacts tested according Annex V
N/A
2.9 (7.2.2
+ 7.2.3)
Earth continuity in joints etc. N/A
2.9 (7.2.4) Locking of clamping means N/A
Compliance with 4.7.3 N/A
www.tuv.com
Page 20 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
Terminal blocks with integrated screwless
earthing contacts tested according Annex V
N/A
2.9 (7.2.5) Earth terminal integral part of connector socket N/A
2.9 (7.2.6) Earth terminal adjacent to mains terminals N/A
2.9 (7.2.7) Electrolytic corrosion of the earth terminal N/A
2.9 (7.2.8) Material of earth terminal N/A
Contact surface bare metal N/A
2.9 (7.2.10) Class II luminaire for looping-in N/A
Double or reinforced insulation to functional earth N/A
2.9 (7.2.11) Earthing core coloured green-yellow N/A
Length of earth conductor N/A
2.10 (14) SCREW TERMINALS N/A
Separately approved; component list (see Annex 1) N/A
Part of the luminaire (see Annex 3) N/A
2.10 (15) SCREWLESS TERMINALS AND ELECTRICAL CONNECTIONS P
Separately approved; component list (see Annex 1) N/A
Part of the luminaire Soldered connection P
2.11 (5) EXTERNAL AND INTERNAL WIRING P
2.11 (5.2) Supply connection and external wiring P
2.11 (5.2.1) Means of connection............................................. : Terminal Block within
approved LED driver
P
2.11 (5.2.2) Type of cable ........................................................ : No supply cord supplied with
Luminaires
N/A
Nominal cross-sectional area (mm²)..................... : N/A
Cables equal to IEC 60227 or IEC 60245 N/A
2.11 (5.2.3) Type of attachment, X, Y or Z N/A
2.11 (5.2.5) Type Z not connected to screws N/A
2.11 (5.2.6) Cable entries: P
www.tuv.com
Page 21 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
- suitable for introduction P
- adequate degree of protection P
2.11 (5.2.7) Cable entries through rigid material have rounded
edges
N/A
2.11 (5.2.8) Insulating bushings: N/A
- suitably fixed N/A
- material in bushings N/A
- material not likely to deteriorate N/A
- tubes or guards made of insulating material N/A
2.11 (5.2.9) Locking of screwed bushings N/A
2.11 (5.2.10) Cord anchorage: P
- covering protected from abrasion P
- clear how to be effective P
- no mechanical or thermal stress P
- no tying of cables into knots etc. P
- insulating material or lining P
2.11
(5.2.10.1)
Cord anchorage for type X attachment: N/A
a) at least one part fixed N/A
b) types of cable N/A
c) no damaging of the cable N/A
d) whole cable can be mounted N/A
e) no touching of clamping screws N/A
f) metal screw not directly on cable N/A
g) replacement without special tool N/A
Glands not used as anchorage N/A
Labyrinth type anchorages N/A
2.11
(5.2.10.2)
Adequate cord anchorage for type Y and type Z
attachment
N/A
2.11
(5.2.10.3)
Tests: P
- impossible to push cable; unsafe P
www.tuv.com
Page 22 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
- pull test: 25 times; pull (N).................................. : 60N P
- torque test: torque (Nm) ..................................... : 0,15Nm P
- displacement  2 mm 0,5mm P
- no movement of conductors P
- no damage of cable or cord P
2.11 (5.2.11) External wiring passing into luminaire N/A
2.11 (5.2.12) Looping-in terminals N/A
2.11 (5.2.13) Wire ends not tinned P
Wire ends tinned: no cold flow N/A
2.11 (5.2.14) Mains plug same protection N/A
Class III luminaire plug N/A
2.11 (5.2.16) Appliance inlets (IEC 60320) N/A
Appliance couplers of class II type N/A
2.11 (5.2.17) No standardized interconnecting cables properly
assembled
N/A
2.11 (5.2.18) Used plug in accordance with N/A
- IEC 60083 N/A
- other standard N/A
2.11 (5.3) Internal wiring P
2.11 (5.3.1) Internal wiring of suitable size and type (see Annex 1) P
Through wiring N/A
- not delivered/ mounting instruction N/A
- factory assembled N/A
- socket outlet loaded (A)...................................... : N/A
- temperatures ...................................................... : (see Annex 2) N/A
Green-yellow for earth only N/A
2.11 (5.3.1.1) Internal wiring connected directly to fixed wiring P
Cross-sectional area (mm²) .................................. : P
Insulation thickness N/A
Extra insulation added where necessary N/A
2.11 (5.3.1.2) Internal wiring connected to fixed wiring via internal current-limiting device N/A
www.tuv.com
Page 23 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
Adequate cross-sectional area and insulation
thickness
N/A
2.11 (5.3.1.3) Double or reinforced insulation for class II P
2.11 (5.3.1.4) Conductors without insulation N/A
2.11 (5.3.1.5) SELV current-carrying parts P
2.11 (5.3.1.6) Insulation thickness other than PVC or rubber N/A
2.11 (5.3.2) Sharp edges etc. P
No moving parts of switches etc. N/A
Joints, raising/lowering devices N/A
Telescopic tubes etc. N/A
No twisting over 360 P
2.11 (5.3.3) Insulating bushings: N/A
- suitable fixed N/A
- material in bushings N/A
- material not likely to deteriorate N/A
- cables with protective sheath N/A
2.11 (5.3.4) Joints and junctions effectively insulated N/A
2.11 (5.3.5) Strain on internal wiring N/A
2.11 (5.3.6) Wire carriers N/A
2.11 (5.3.7) Wire ends not tinned P
Wire ends tinned: no cold flow N/A
2.12 (8) PROTECTION AGAINST ELECTRIC SHOCK P
2.12 (8.2.1) Live parts not accessible P
Basic insulated parts not used on the outer
surface without appropriate protection
P
Basic insulated parts not accessible with standard
test finger on portable and adjustable luminaires
N/A
Basic insulated parts not accessible with Ø 50
mm probe from outside, within arm’s reach, on
wall-mounted luminaires
N/A
www.tuv.com
Page 24 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
Lamp and starterholders in portable and
adjustable luminaires comply with double or
reinforced insulation requirements
N/A
Basic insulation only accessible under lamp or
starter replacement
N/A
Protection in any position P
Double-ended tungsten filament lamp N/A
Insulation lacquer not reliable N/A
Double-ended high pressure discharge lamp N/A
Relevant warning according to 3.2.18 fitted to the
luminaire
N/A
2.12 (8.2.2) Portable luminaire adjusted in most unfavourable
position
N/A
2.12 (8.2.3.a) Class II luminaire: P
- basic insulated metal parts not accessible during
starter or lamp replacement
N/A
- basic insulation not accessible other than during
starter or lamp replacement
P
- glass protective shields not used as
supplementary insulation
N/A
2.12 (8.2.3.b) BC lampholder of metal in class I luminaires shall
be earthed
N/A
2.12 (8.2.3.c) Class III luminaires with exposed SELV parts: P
Ordinary luminaire: P
- touch current ...................................................... : N/A
- no-load voltage ................................................... : Max. 50V P
Other than ordinary luminaire: N/A
- nominal voltage ................................................. : N/A
2.12 (8.2.4) Portable luminaire have protection independent of
supporting surface
N/A
2.12 (8.2.5) Compliance with the standard test finger or
relevant probe
P
2.12 (8.2.6) Covers reliably secured N/A
2.12 (8.2.7) Discharging of capacitors  0,5 F Approved LED Driver N/A
www.tuv.com
Page 25 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
Portable plug connected luminaire with capacitor N/A
Other plug connected luminaire with capacitor N/A
Discharge device on or within capacitor N/A
Discharge device mounted separately N/A
2.13 (12) ENDURANCE TEST AND THERMAL TEST P
2.13 (-) If IP > IP 20 relevant test of (12.4), (12.5) and (12.6) after (9.2) before (9.3)
specified in 2.14

2.13 (12.3) Endurance test: P
- mounting-position ............................................... : On the black testing box 
- test temperature (C).......................................... : 45C 
- total duration (h) ................................................. : 240h 
- supply voltage: Un factor; calculated voltage (V): 264V 
- lamp used ........................................................... : LED Module 
2.13 (12.3.2) After endurance test: P
- no part unserviceable P
- luminaire not unsafe P
- no damage to track system N/A
- marking legible P
- no cracks, deformation etc. P
2.13 (12.4) Thermal test (normal operation) (see Annex 2) P
2.13 (12.5) Thermal test (abnormal operation) (see Annex 2) N/A
2.13 (12.6) Thermal test (failed lamp control gear condition): N/A
2.13 (12.6.1) Through wiring or looping-in wiring loaded by a
current of (A) ........................................................ :

- case of abnormal conditions............................... : 
- electronic lamp control gear N/A
- measured winding temperature (C): at 1,1 Un . : 
- measured mounting surface temperature (C) at
1,1 Un ................................................................... :
N/A
- calculated mounting surface temperature (C) .. : N/A
www.tuv.com
Page 26 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
- track-mounted luminaires N/A
2.13 (12.6.2) Temperature sensing control N/A
- case of abnormal conditions............................... : 
- thermal link N/A
- manual reset cut-out N/A
- auto reset cut-out N/A
- measured mounting surface temperature (C)... : N/A
- track-mounted luminaires N/A
2.13 (12.7) Thermal test (failed lamp control gear in plastic luminaires): N/A
2.13 (12.7.1) Luminaire without temperature sensing control N/A
2.13
(12.7.1.1)
Luminaire with fluorescent lamp ≤ 70W N/A
Test method 12.7.1.1 or Annex W ....................... : 
Test according to 12.7.1.1: N/A
- case of abnormal conditions 
- Ballast failure at supply voltage (V) ................... : 
- Components retained in place after the test N/A
- Test with standard test finger after the test N/A
Test according to Annex W: N/A
- case of abnormal conditions 
- measured winding temperature (C): at 1,1 Un.. : 
- measured temperature of fixing point/exposed
part (C): at 1,1 Un................................................ :

- calculated temperature of fixing point/exposed
part (C) ................................................................ :

Ball-pressure test: N/A
- part tested; temperature (C).............................. : N/A
- part tested; temperature (C).............................. : N/A
2.13
(12.7.1.2)
Luminaire with discharge lamp, fluorescent lamp > 70W, transformer > 10 VA N/A
- case of abnormal conditions 
www.tuv.com
Page 27 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
- measured winding temperature (C): at 1,1 Un.. : 
- measured temperature of fixing point/exposed
part (C): at 1,1 Un................................................ :

- calculated temperature of fixing point/exposed
part (C) ................................................................ :

Ball-pressure test: N/A
- part tested; temperature (C).............................. : N/A
- part tested; temperature (C).............................. : N/A
2.13
(12.7.1.3)
Luminaire with short circuit proof transformers
≤ 10 VA
N/A
- case of abnormal conditions 
- Components retained in place after the test N/A
- Test with standard test finger after the test N/A
2.13 (12.7.2) Luminaire with temperature sensing control N/A
- thermal link Yes No 
- manual reset cut-out Yes No 
- auto reset cut-out Yes No 
- case of abnormal conditions 
- highest measured temperature of fixing
point/exposed part (C):........................................ :

Ball-pressure test: N/A
- part tested; temperature (C).............................. : N/A
- part tested; temperature (C).............................. : N/A
2.13.1 (-) Wiring, for connection to the supply, not reach unsafe temperature N/A
- measured temperature of the cable (C) ........... : N/A
2.14 (9) RESISTANCE TO DUST, SOLID OBJECTS AND MOISTURE P
2.14 (-) If IP > IP 20 the order of the test specified in clause 2.13 
2.14 (9.2) Tests for ingress of dust, solid objects and moisture: P
- classification according to IP .............................. : IP20 
- mounting position during test ............................. : On the testing ceiling. 
www.tuv.com
Page 28 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
- fixing screws tightened; torque (Nm).................. : 
- tests according to clauses .................................. : Clause 9.2.0 
- electric strength test afterwards N/A
a) no deposit in dust-proof luminaire N/A
b) no talcum in dust-tight luminaire N/A
c) no trace of water on current-carrying parts or
SELV parts or where it could become a hazard
N/A
d) i) For luminaires without drain holes – no water
entry
N/A
d) ii) For luminaires with drain holes – no
hazardous water entry
N/A
e) no water in watertight luminaire N/A
f) no contact with live parts (IP 2X) IP20 P
f) no entry into enclosure (IP 3X and IP 4X) N/A
f) no contact with live parts (IP3X and IP4X) N/A
g) no trace of water on part of lamp requiring
protection from splashing water
N/A
h) no damage of protective shield or glass
envelope
N/A
2.14 (9.3) Humidity test 48 h 25C, 93%R.H. for 48 h P
2.15 (10) INSULATION RESISTANCE AND ELECTRIC STRENGTH P
2.15 (10.2.1) Insulation resistance test P
Cable or cord covered by metal foil or replaced by
a metal rod of mm Ø ............................................ :

Insulation resistance (M) 
SELV: P
- between current-carrying parts of different
polarity .................................................................. :
N/A
- between current-carrying parts and mounting
surface .................................................................. :
Min99,9 G > 1 M P
- between current-carrying parts and metal parts
of the luminaire ..................................................... :
Min99,9 G > 1 M P
www.tuv.com
Page 29 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
- between the outer surface of a flexible cord or
cable where it is clamped in a cord anchorage
and accessible metal parts ................................... :
N/A
- Insulation bushings as described in Section 5 .. : N/A
Other than SELV: P
- between live parts of different polarity................ : N/A
- between live parts and mounting surface........... : Min 99,9 G > 4 M P
- between live parts and metal parts..................... : Min 99,9 G > 4 M P
- between live parts of different polarity through
action of a switch .................................................. :
N/A
- between the outer surface of a flexible cord or
cable where it is clamped in a cord anchorage
and accessible metal parts ................................... :
N/A
- Insulation bushings as described in Section 5 .. : N/A
2.15 (10.2.2) Electric strength test P
Dummy lamp N/A
Luminaires with ignitors after 24 h test N/A
Luminaires with manual ignitors N/A
Test voltage (V): P
SELV: P
- between current-carrying parts of different
polarity .................................................................. :
N/A
- between current-carrying parts and mounting
surface .................................................................. :
500 V for all models P
- between current-carrying parts and metal parts
of the luminaire ..................................................... :
500 V for all models P
- between the outer surface of a flexible cord or
cable where it is clamped in a cord anchorage
and accessible metal parts ................................... :
N/A
- Insulation bushings as described in Section 5 .. : N/A
Other than SELV: P
- between live parts of different polarity................ : N/A
- between live parts and mounting surface........... : 2960V for all models P
- between live parts and metal parts..................... : 2960V for all models P
www.tuv.com
Page 30 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
- between live parts of different polarity through
action of a switch .................................................. :
N/A
- between the outer surface of a flexible cord or
cable where it is clamped in a cord anchorage
and accessible metal parts ................................... :
N/A
- Insulation bushings as described in Section 5 .. : N/A
2.15 (10.3) Touch current or protective conductor current
(mA) ...................................................................... :
Max 0,08mA P
2.16 (13) RESISTANCE TO HEAT, FIRE AND TRACKING P
2.16 (13.2.1) Ball-pressure test: P
- part tested; temperature (C).............................. : connector: 125C, 0,9 mm P
- part tested; temperature (C).............................. : N/A
2.16 (13.3.1) Needle flame test (10 s): N/A
- part tested........................................................... : N/A
- part tested........................................................... : N/A
2.16 (13.3.2) Glow-wire test (650C): P
- part tested........................................................... : Connector , LED Cover P
- part tested........................................................... : N/A
2.16 (13.4.1) Tracking test: N/A
- part tested........................................................... : N/A
- part tested........................................................... : N/A
www.tuv.com
Page 31 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
ANNEX 1: components P
object/part No.
cod
e
manufacturer/
trademark
type/model technical data
standar
d
mark(s) of
conformity
LED Driver
(for 40W
Models)
B
Shenzhen
Ledfriend
Optoelectronics
Co., Ltd
LF-GIR040YX1000A(Z)
Independent SELV
LED Driver ;
Input 200-240V~,
50/60Hz, Max
0,5A; output 27-
42Vdc,1000mA;
ta:40C, tc:80C
--
TUV SUD
B 14 05
74050 009
LED Driver
(for 30W
Models)
B
Shenzhen
Ledfriend
Optoelectronics
Co., Ltd
LF-GIR030YX0750A(Z)
Independent SELV
LED Driver ;
Input 200-240V~,
50/60Hz, Max
0,4A; output 27-
40Vdc,750mA;
ta:40C, tc:70C
--
TUV SUD
B 14 05
74050 009
LED Driver
(for 20W
Models)
B
Shenzhen
Ledfriend
Optoelectronics
Co., Ltd
LF-GIR022YX0540A(Z)
Independent SELV
LED Driver ;
Input 200-240V~,
50/60Hz, Max
0,3A; output 27-
42Vdc,540mA;
ta:40C, tc:70C
--
TUV SUD
B 14 05
74050 009
LED Driver
(for 15W
Models)
B
Shenzhen
Ledfriend
Optoelectronics
Co., Ltd
LF-GIR015YX0380A(Z)
Independent SELV
LED Driver ;
Input 200-240V~,
50/60Hz, Max
0,2A; output 27-
42Vdc,380mA;
ta:40C, tc:70C
--
TUV SUD
B 14 05
74050 009
LED Driver
(for 12W
Models)
B
Shenzhen
Ledfriend
Optoelectronics
Co., Ltd
LF-GIR010YX0250A(Z)
Independent SELV
LED Driver ;
Input 200-240V~,
50/60Hz, Max
0,2A; output 27-
42Vdc, 250mA;
ta:40C, tc:70C
--
TUV SUD
B 14 05
74050 009
www.tuv.com
Page 32 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
Output wire B,C
HUMEN
XINTAI
ELECTRICAL
WIRES
FACTORY
2464
18AWG,VW-
1,300V
--
Test with
appliance
LED Cover B,C
HUIZHOU
BOYU
TECHNOLOGY
CO LTD
AL-01-P EP --
Test with
appliance
Connector B,C
XingdeElectroni
cs., LTD
5,5X2,1 220V,4A --
Test with
appliance
LED(SMD) B,C Samsung LM561B(5630)
150mA,
2,7Vdc-3,2Vdc
2700K-6500K
--
Test with
appliance
LED(COB) B,C CREE INC CXA2530 Serial
800mA,
37,9Vdc-42Vdc
2700K-5000K
--
Test with
appliance
(Alternative)
COB
D CREE INC CXA1512 Serial
350mA,
38Vdc-42Vdc
2700K-5000K
--
Test with
appliance
(Alternative)
COB
D CREE INC CXA1816 Serial
Max.900mA,
37Vdc
2700K-5000K
--
Test with
appliance
(Alternative)
COB
D CREE INC CXA1507 Serial
750mA or 375mA
18Vdc or 37Vdc
2700K-5000K
--
Test with
appliance
(Alternative)
COB
D CREE INC CXA2520 Serial
550mA-1250mA,
36Vdc-42Vdc
2700K-5000K
--
Test with
appliance
www.tuv.com
Page 33 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
(Alternative)
COB
D
CITIZEN
ELECTRONIC
S CO., Ltd
CLL022 Serial
CLL032 Serial
36,2Vdc,
120mA or 180mA
or 240mA (for CLL
022 Serial),
300mA or 360mA
or 480mA or
720mA (for CLL
032 Serial),
2700K-5000K
--
Test with
appliance
The codes above have the following meaning:
A - The component is replaceable with another one, also certified, with equivalent characteristics
B - The component is replaceable if authorised by the test house
C - Integrated component tested together with the appliance
D - Alternative component
www.tuv.com
Page 34 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
ANNEX 2: temperature measurements, thermal tests of Section 12 P
Type reference .....................................................: XH-HDLR-40W-X6 
Lamp used............................................................: LED module 
Lamp control gear used .......................................: Mode: LF-GIR040YX1000A(Z)
Input: 220-240V~, 50/60Hz;
Output: 27V-42VDC, 1000mA;
Max.ouput:50Vdc; tc=80ºC.

Mounting position of luminaire .............................: On the black ceiling 
Supply wattage (W)..............................................: 37,4 W 
Supply current (A) ................................................: 0,183 A 
Calculated power factor .......................................: ----- 
Table: measured temperatures corrected for ta =35C:
- abnormal operating mode..................................: Short-circuit of LED driver
output.

- test 1: rated voltage ...........................................: N/A 
- test 2: 1,06 times rated voltage or 1,05 times
rated wattage........................................................:
254,4V 
- test 3: Load on wiring to socket-outlet,
1,06 times voltage or 1,05 times wattage ............:
N/A 
- test 4: 1,1 times rated voltage or 1,05 times
rated wattage........................................................:
N/A 
Through wiring or looping-in wiring loaded by a
current of A during the test ..................................:
N/A 
temperature (C) of part Clause 12.4 – normal Clause 12.5 – abnormal
test 1 test 2 test 3 limit test 4 limit
Supply wire -- 49,9ºC -- Ref. -- --
Outside surface of LED
driver (tc)
-- 69,7ºC -- 80,0ºC -- --
Output wire -- 56,7ºC -- 90,0ºC -- --
Connector 45,9ºC Ref.
Wire to LED -- 66,7ºC -- 90,0ºC -- --
LED PCB -- 67,9ºC -- Ref. -- --
www.tuv.com
Page 35 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
LED Cover -- 64,1ºC -- Ref. -- --
Inside recessed box -- 61,1ºC -- 90,0ºC -- --
Light object(0,1 m) -- 47,5ºC -- 90,0ºC -- --
Mounting surface -- 52,3ºC -- 90,0ºC -- --
Type reference .....................................................: XH-HDLR-30W-X5 
Lamp used............................................................: LED module 
Lamp control gear used .......................................: Mode: LF-GIR030YX0750A(Z)
Input: 220-240V~, 50/60Hz;
Output: 27V-40VDC, 750mA;
Max.ouput:50Vdc; tc=70ºC.

Mounting position of luminaire .............................: On the black ceiling 
Supply wattage (W)..............................................: 30,1 W 
Supply current (A) ................................................: 0,125 A 
Calculated power factor .......................................: ----- 
Table: measured temperatures corrected for ta =35C:
- abnormal operating mode..................................: Short-circuit of LED driver
output.

- test 1: rated voltage ...........................................: N/A 
- test 2: 1,06 times rated voltage or 1,05 times
rated wattage........................................................:
254,4V 
- test 3: Load on wiring to socket-outlet,
1,06 times voltage or 1,05 times wattage ............:
N/A 
- test 4: 1,1 times rated voltage or 1,05 times
rated wattage........................................................:
N/A 
Through wiring or looping-in wiring loaded by a
current of A during the test ..................................:
N/A 
temperature (C) of part Clause 12.4 – normal Clause 12.5 – abnormal
test 1 test 2 test 3 limit test 4 limit
Supply wire -- 44,6ºC -- Ref. -- --
Outside surface of LED
driver (tc)
-- 69,3ºC -- 70,0ºC -- --
Output wire -- 47,1ºC -- 90,0ºC -- --
www.tuv.com
Page 36 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
Connector -- 42,9ºC -- Ref. -- --
Wire to LED -- 62,3ºC -- 90,0ºC -- --
LED PCB -- 64,6ºC -- Ref. -- --
LED Cover -- 58,7ºC -- Ref. -- --
Inside recessed box
-- 58,4ºC -- 90,0ºC -- --
Light object(0,1 m) -- 47,9ºC -- 90,0ºC -- --
Mounting surface -- 47,2ºC -- 90,0ºC -- --
Type reference .....................................................: XH-HDLR-30W-X3 
Lamp used............................................................: LED module 
Lamp control gear used .......................................: Mode: LF-GIR030YX0750A(Z)
Input: 220-240V~, 50/60Hz;
Output: 27V-40VDC, 750mA;
Max.ouput:50Vdc; tc=70ºC

Mounting position of luminaire .............................: On the black ceiling 
Supply wattage (W)..............................................: 30,1 W 
Supply current (A) ................................................: 0,124 A 
Calculated power factor .......................................: ----- 
Table: measured temperatures corrected for ta =35C:
- abnormal operating mode..................................: Short-circuit of LED driver
output.

- test 1: rated voltage ...........................................: N/A 
- test 2: 1,06 times rated voltage or 1,05 times
rated wattage........................................................:
254,4V 
- test 3: Load on wiring to socket-outlet,
1,06 times voltage or 1,05 times wattage ............:
N/A 
- test 4: 1,1 times rated voltage or 1,05 times
rated wattage........................................................:
N/A 
Through wiring or looping-in wiring loaded by a
current of A during the test ..................................:
N/A 
temperature (C) of part Clause 12.4 – normal Clause 12.5 – abnormal
test 1 test 2 test 3 limit test 4 limit
www.tuv.com
Page 37 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
Supply wire -- 43,3ºC -- Ref. -- --
Outside surface of LED
driver (tc)
-- 69,7ºC -- 70,0ºC -- --
Output wire -- 48,3ºC -- 90,0ºC -- --
Connector -- 47,7ºC -- Ref. -- --
Wire to LED -- 65,7ºC -- 90,0ºC -- --
LED PCB -- 66,2ºC -- Ref. -- --
LED Cover -- 35,6ºC -- Ref. -- --
Inside recessed box -- 70,1ºC -- 90,0ºC -- --
Light object(0,1 m) -- 44,2ºC -- 90,0ºC -- --
Mounting surface -- 47,9ºC -- 90,0ºC -- --
Type reference .....................................................: XH-CDLR-40W-X6 
Lamp used............................................................: LED module 
Lamp control gear used .......................................: Mode: LF-GIR040YX1000A(Z)
Input: 220-240V~, 50/60Hz;
Output: 27V-42VDC, 1000mA;
Max.ouput:50Vdc; tc=80ºC.

Mounting position of luminaire .............................: On the black ceiling 
Supply wattage (W)..............................................: 36,1 W 
Supply current (A) ................................................: 0,149 A 
Calculated power factor .......................................: ----- 
Table: measured temperatures corrected for ta =35C:
- abnormal operating mode..................................: Short-circuit of LED driver
output.

- test 1: rated voltage ...........................................: N/A 
- test 2: 1,06 times rated voltage or 1,05 times
rated wattage........................................................:
254,4V 
- test 3: Load on wiring to socket-outlet,
1,06 times voltage or 1,05 times wattage ............:
N/A 
- test 4: 1,1 times rated voltage or 1,05 times
rated wattage........................................................:
N/A 
www.tuv.com
Page 38 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
Through wiring or looping-in wiring loaded by a
current of A during the test ..................................:
N/A 
temperature (C) of part Clause 12.4 – normal Clause 12.5 – abnormal
test 1 test 2 test 3 limit test 4 limit
Supply wire -- 43,3ºC -- Ref. -- --
Outside surface of LED
driver (tc)
-- 69,0ºC -- 80,0ºC -- --
Output wire -- 48,7ºC -- 90,0ºC -- --
Connector -- 46,0ºC -- Ref. -- --
Wire to LED -- 66,9ºC -- 90,0ºC -- --
LED PCB -- 73,0ºC -- Ref. -- --
LED Cover -- 53,6ºC -- Ref. -- --
Inside recessed box -- 68,2ºC -- 90,0ºC -- --
Light object(0,1 m) -- 41,1ºC -- 90,0ºC -- --
Mounting surface -- 53,4ºC -- 90,0ºC -- --
Type reference .....................................................: XH-CDLR-40W-X4 
Lamp used............................................................: LED module 
Lamp control gear used .......................................: Mode: LF-GIR040YX1000A(Z)
Input: 220-240V~, 50/60Hz;
Output: 27V-42VDC, 1000mA;
Max.ouput:50Vdc; tc=80ºC.

Mounting position of luminaire .............................: On the black ceiling 
Supply wattage (W)..............................................: 40,8 W 
Supply current (A) ................................................: 0,165 A 
Calculated power factor .......................................: ----- 
Table: measured temperatures corrected for ta =35C:
- abnormal operating mode..................................: Short-circuit of LED driver
output.

- test 1: rated voltage ...........................................: N/A 
www.tuv.com
Page 39 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
- test 2: 1,06 times rated voltage or 1,05 times
rated wattage........................................................:
254,4V 
- test 3: Load on wiring to socket-outlet,
1,06 times voltage or 1,05 times wattage ............:
N/A 
- test 4: 1,1 times rated voltage or 1,05 times
rated wattage........................................................:
N/A 
Through wiring or looping-in wiring loaded by a
current of A during the test ..................................:
N/A 
temperature (C) of part Clause 12.4 – normal Clause 12.5 – abnormal
test 1 test 2 test 3 limit test 4 limit
Supply wire -- 46,4ºC -- Ref. -- --
Outside surface of LED
driver (tc)
-- 69,0ºC -- 80,0ºC -- --
Output wire -- 56,2ºC -- 90,0ºC -- --
Connector -- 46,2ºC -- Ref. -- --
Wire to LED -- 74,0ºC -- 90,0ºC -- --
LED PCB -- 79,5ºC -- Ref. -- --
LED Cover -- 71,5ºC -- Ref. -- --
Inside recessed box -- 48,2ºC -- 90,0ºC -- --
Light object(0,1 m) -- 42,0ºC -- 90,0ºC -- --
Mounting surface -- 44,5ºC -- 90,0ºC -- --
Type reference .....................................................: XH-CDLR-30W-X5 
Lamp used............................................................: LED module 
Lamp control gear used .......................................: Mode: LF-GIR030YX0750A(Z)
Input: 220-240V~, 50/60Hz;
Output: 27V-40VDC, 750mA;
Max.ouput:50Vdc; tc=70ºC

Mounting position of luminaire .............................: On the black ceiling 
Supply wattage (W)..............................................: 28,3 W 
Supply current (A) ................................................: 0,117 A 
Calculated power factor .......................................: ----- 
Table: measured temperatures corrected for ta =35C:
www.tuv.com
Page 40 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
- abnormal operating mode..................................: Short-circuit of LED driver
output.

- test 1: rated voltage ...........................................: N/A 
- test 2: 1,06 times rated voltage or 1,05 times
rated wattage........................................................:
254,4V 
- test 3: Load on wiring to socket-outlet,
1,06 times voltage or 1,05 times wattage ............:
N/A 
- test 4: 1,1 times rated voltage or 1,05 times
rated wattage........................................................:
N/A 
Through wiring or looping-in wiring loaded by a
current of A during the test ..................................:
N/A 
temperature (C) of part Clause 12.4 – normal Clause 12.5 – abnormal
test 1 test 2 test 3 limit test 4 limit
Supply wire -- 42,9ºC -- Ref. -- --
Outside surface of LED
driver (tc)
-- 69,7ºC -- 70,0ºC -- --
Output wire -- 46,6ºC -- 90,0ºC -- --
Connector -- 49,1ºC -- Ref. -- --
Wire to LED -- 66,2ºC -- 90,0ºC -- --
LED PCB -- 73,0ºC -- Ref. -- --
LED Cover -- 51,4ºC -- Ref. -- --
Inside recessed box -- 64,6ºC -- 90,0ºC -- --
Light object(0,1 m) -- 40,8ºC -- 90,0ºC -- --
Mounting surface -- 48,3ºC -- 90,0ºC -- --
Type reference .....................................................: XH-CDLR-20W-X4 
Lamp used............................................................: LED module 
Lamp control gear used .......................................: Mode: LF-GIR022YX0540A(Z)
Input: 220-240V~, 50/60Hz;
Output: 27V-42VDC, 540mA;
Max.ouput:50Vdc; tc=70ºC

Mounting position of luminaire .............................: On the black ceiling 
Supply wattage (W)..............................................: 19,9 W 
www.tuv.com
Page 41 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
Supply current (A) ................................................: 0,082 A 
Calculated power factor .......................................: ----- 
Table: measured temperatures corrected for ta =35C:
- abnormal operating mode..................................: Short-circuit of LED driver
output.

- test 1: rated voltage ...........................................: N/A 
- test 2: 1,06 times rated voltage or 1,05 times
rated wattage........................................................:
254,4V 
- test 3: Load on wiring to socket-outlet,
1,06 times voltage or 1,05 times wattage ............:
N/A 
- test 4: 1,1 times rated voltage or 1,05 times
rated wattage........................................................:
N/A 
Through wiring or looping-in wiring loaded by a
current of A during the test ..................................:
N/A 
temperature (C) of part Clause 12.4 – normal Clause 12.5 – abnormal
test 1 test 2 test 3 limit test 4 limit
Supply wire -- 41,0ºC -- Ref. -- --
Outside surface of LED
driver (tc)
-- 60,2ºC -- 70,0ºC -- --
Output wire -- 51,1ºC -- 90,0ºC -- --
Connector -- 39,9ºC -- Ref. -- --
Wire to LED -- 65,9ºC -- 90,0ºC -- --
LED PCB -- 72,3ºC -- Ref. -- --
LED Cover -- 63,8ºC -- Ref. -- --
Inside recessed box -- 42,6ºC -- 90,0ºC -- --
Light object(0,1 m) -- 38,7ºC -- 90,0ºC -- --
Mounting surface -- 40,5ºC -- 90,0ºC -- --
Type reference .....................................................: XH-CDLR-15W-X4 
Lamp used............................................................: LED module 
www.tuv.com
Page 42 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
Lamp control gear used .......................................: Mode: LF-GIR015YX0380A(Z)
Input: 220-240V~, 50/60Hz;
Output: 27V-42VDC, 380mA;
Max.ouput:50Vdc; tc=70ºC

Mounting position of luminaire .............................: On the black ceiling 
Supply wattage (W)..............................................: 15,2 W 
Supply current (A) ................................................: 0,063 A 
Calculated power factor .......................................: ----- 
Table: measured temperatures corrected for ta =35C:
- abnormal operating mode..................................: Short-circuit of LED driver
output.

- test 1: rated voltage ...........................................: N/A 
- test 2: 1,06 times rated voltage or 1,05 times
rated wattage........................................................:
254,4V 
- test 3: Load on wiring to socket-outlet,
1,06 times voltage or 1,05 times wattage ............:
N/A 
- test 4: 1,1 times rated voltage or 1,05 times
rated wattage........................................................:
N/A 
Through wiring or looping-in wiring loaded by a
current of A during the test ..................................:
N/A 
temperature (C) of part Clause 12.4 – normal Clause 12.5 – abnormal
test 1 test 2 test 3 limit test 4 limit
Supply wire -- 39,8ºC -- Ref. -- --
Outside surface of LED
driver (tc)
-- 57,3ºC -- 70,0ºC -- --
Output wire -- 50,0ºC -- 90,0ºC -- --
Connector -- 38,1ºC -- Ref. -- --
Wire to LED -- 60,9ºC -- 90,0ºC -- --
LED PCB -- 68,7ºC -- Ref. -- --
LED Cover -- 59,9ºC -- Ref. -- --
Inside recessed box -- 38,6ºC -- 90,0ºC -- --
Light object(0,1 m) -- 37,1ºC -- 90,0ºC -- --
Mounting surface -- 37,9ºC -- 90,0ºC -- --
www.tuv.com
Page 43 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
Type reference .....................................................: XH-CDLR-12W-X4 
Lamp used............................................................: LED module 
Lamp control gear used .......................................: Mode: LF-GIR010YX0250A(Z)
Input: 220-240V~, 50/60Hz;
Output: 27V-42VDC, 250mA;
Max.ouput:50Vdc; tc=70ºC

Mounting position of luminaire .............................: On the black ceiling 
Supply wattage (W)..............................................: 11,9 W 
Supply current (A) ................................................: 0,049 A 
Calculated power factor .......................................: ----- 
Table: measured temperatures corrected for ta =35C:
- abnormal operating mode..................................: Short-circuit of LED driver
output.

- test 1: rated voltage ...........................................: N/A 
- test 2: 1,06 times rated voltage or 1,05 times
rated wattage........................................................:
254,4V 
- test 3: Load on wiring to socket-outlet,
1,06 times voltage or 1,05 times wattage ............:
N/A 
- test 4: 1,1 times rated voltage or 1,05 times
rated wattage........................................................:
N/A 
Through wiring or looping-in wiring loaded by a
current of A during the test ..................................:
N/A 
temperature (C) of part Clause 12.4 – normal Clause 12.5 – abnormal
test 1 test 2 test 3 limit test 4 limit
Supply wire -- 38,7ºC -- Ref. -- --
Outside surface of LED
driver (tc)
-- 56,2ºC -- 70,0ºC -- --
Output wire -- 49,7ºC -- 90,0ºC -- --
Connector -- 37,4ºC -- Ref. -- --
Wire to LED -- 59,9ºC -- 90,0ºC -- --
LED PCB -- 66,4ºC -- Ref. -- --
LED Cover -- 58,0ºC -- Ref. -- --
www.tuv.com
Page 44 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
Inside recessed box -- 38,0ºC -- 90,0ºC -- --
Light object(0,1 m) -- 36,5ºC -- 90,0ºC -- --
Mounting surface -- 37,0ºC -- 90,0ºC -- --
www.tuv.com
Page 45 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
ANNEX 3: screw terminals (part of the luminaire) N/A
(14) SCREW TERMINALS N/A
(14.2) Type of terminal................................................... : 
Rated current (A)................................................. : 
(14.3.2.1) One or more conductors N/A
(14.3.2.2) Special preparation N/A
(14.3.2.3) Terminal size N/A
Cross-sectional area (mm²)................................. : N/A
(14.3.3) Conductor space (mm)........................................ : N/A
(14.4) Mechanical tests N/A
(14.4.1) Minimum distance N/A
(14.4.2) Cannot slip out N/A
(14.4.3) Special preparation N/A
(14.4.4) Nominal diameter of thread (metric ISO thread) . : N/A
External wiring N/A
No soft metal N/A
(14.4.5) Corrosion N/A
(14.4.6) Nominal diameter of thread (mm) ....................... : N/A
Torque (Nm) ........................................................ : N/A
(14.4.7) Between metal surfaces N/A
Lug terminal N/A
Mantle terminal N/A
Pull test; pull (N) .................................................. : N/A
(14.4.8) Without undue damage N/A
www.tuv.com
Page 46 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
ANNEX 4: screwless terminals (part of the luminaire) N/A
(15) SCREWLESS TERMINALS N/A
(15.2) Type of terminal................................................... : 
Rated current (A)................................................. : 
(15.3.1) Material N/A
(15.3.2) Clamping N/A
(15.3.3) Stop N/A
(15.3.4) Unprepared conductors N/A
(15.3.5) Pressure on insulating material N/A
(15.3.6) Clear connection method N/A
(15.3.7) Clamping independently N/A
(15.3.8) Fixed in position N/A
(15.3.10) Conductor size N/A
Type of conductor N/A
(15.5.1) Terminals internal wiring N/A
(15.5.1.1) Pull test spring-type terminals (4 N,
4 samples)….:
N/A
(15.5.1.2) Pull test pin or tab terminals (4 N,
4 samples)……:
N/A
Insertion force not exceeding 50 N N/A
(15.5.1.2) Permanent connections: pull-off test (20 N) N/A
(15.6) Electrical tests N/A
Voltage drop (mV) after 1 h (4 samples)............. : N/A
Voltage drop of two inseparable joints N/A
Number of cycles................................................. : 
Voltage drop (mV) after 10th alt. 25th cycle
(4 samples).......................................................... :
N/A
Voltage drop (mV) after 50th alt. 100th cycle
(4 samples).......................................................... :
N/A
www.tuv.com
Page 47 of 52 Report No. 17044083 001
IEC 60598-2-2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_2C
After ageing, voltage drop (mV) after 10th alt.
25th cycle (4 samples) ........................................ :
N/A
After ageing, voltage drop (mV) after 50th alt.
100th cycle (4 samples) ...................................... :
N/A
(15.7) Terminals external wiring N/A
Terminal size and rating N/A
(15.8.1) Pull test spring-type terminals or welded
connections (4 samples); pull (N) ....................... :
N/A
Pull test pin or tab terminals (4 samples);
pull (N) ................................................................ :
N/A
(15.9) Contact resistance test N/A
Voltage drop (mV) after 1 h N/A
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
Voltage drop of two inseparable joints N/A
Voltage drop after 10th alt. 25th cycle N/A
Max. allowed voltage drop (mV)................ : 
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
Voltage drop after 50th alt. 100th cycle N/A
Max. allowed voltage drop (mV)................ : 
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
Continued ageing: voltage drop after 10th alt. 25th cycle N/A
Max. allowed voltage drop (mV)................ : 
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
Continued ageing: voltage drop after 50th alt. 100th cycle N/A
Max. allowed voltage drop (mV)................ : 
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
www.tuv.com
Page 48 of 52 Report No. 17044083 001
Annex 5: EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
Luminaires
Part 2: Particular requirements:
Section Two – Recessed luminaires
Differences according ....................: EN 60598-2-2:2012 used in conjunction with
EN 60598-1:2008 + A11:2009
Annex Form No...............................: EU_GD_IEC60598_2_2B
Annex Form Originator .....................: IMQ S.p.A.
Master Annex Form..........................: 2012-11
Copyright © 2012 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
CENELEC COMMON MODIFICATIONS (EN) P
2.5 (3) MARKING N/A
2.5 (3.3.101) Adequate warning on the package N/A
2.6 (4) CONSTRUCTION P
2.6 (4.11.6) Electro-mechanical contact systems P
2.10 (5) EXTERNAL AND INTERNAL WIRING N/A
2.10 (5.2.1) Connecting leads N/A
- without a means for connection to the supply N/A
- terminal block specified N/A
- relevant information provided N/A
- compliance with 4.6, 4.7.1, 4.7.2, 4.10.1, 11.2,
12 and 13.2 of Part 1
N/A
2.10 (5.2.2) Cables equal to HD21 S2 or HD22 S2 N/A
2.12 (12) ENDURANCE TEST AND THERMAL TEST P
2.12 (12.4.2c) Thermal test (normal operation) P
ZB ANNEX ZB, SPECIAL NATIONAL CONDITIONS (EN) N/A
(3.3) DK: power supply cord with label N/A
IT: warning label on Class 0 luminaire N/A
www.tuv.com
Page 49 of 52 Report No. 17044083 001
Annex 5: EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
(4.5.1) DK: socket-outlets N/A
(5.2.1) CY, DK, FI, SE, GB: type of plug N/A
ZC ANNEX ZC, NATIONAL DEVIATIONS (EN) N/A
(4 & 5) FR: Shuttered socket-outlets 10/16A N/A
(13.3)
FR: Glow-wire test 850C alt. 750C for
luminaires in premises open to public or 960°C
for luminaires in emergency exits
N/A
(13.3)
GB: Requirements according to United Kingdom
Building Regulation
N/A
www.tuv.com
Page 50 of 52 Report No. 17044083 001
Annex 6 LED modules for general lighting —Safety specifications EN 62031: 2008+
A1:2013
P
Clause Requirement – Test Result - Remark Verdict
13.2 Module withstands overpower condition >15 min. P
Module with automatic protective device or power
limiter, test performed 15 min. at limit.
P
During the tests, tissue paper, spread below
module, does not ignite
P
14 Conformity testing during manufacture Tested as a part of luminaire P
17 Screws, current-carrying parts and connections P
The requirements of IEC 61347-1, Clause 17,
apply.
P
www.tuv.com
Page 51 of 52 Report No. 17044083 001
Annex 7 Photobiological safety of lamps and lamp systems were according
to standard EN 62471:2008 and EU Directive 2006/25/EC.
Exempt group, this classification applied for all models
P
XH-HDLR-40W-X6 with CCT 6500K, SMD5630 LED , Exempt group
α=100,00mrad, Measure distant:1,3mm
Optical hazard Test result Used hazard exposure limit Ref.
Es 1,386E-07 W/m
2
0,001 W/m
2
200-400 nm P
EUVA 3,295E-03 W/m
2
0,33 W/m
2
315-400 nm P
LB 3,002E+01 W/m
2
sr 100 W/m
2
sr 300-700 nm P
EB (small source) -- -- 300-700 nm N/A
LR 4,185E+02 W/m
2
sr 2.800E+05 W/m
2
sr 380-1400 nm P
LIR 1,780E-02 W/m
2
sr 6.000E+04 W/m
2
sr 780-1400 nm P
EIR 0,000E+00 W/m
2
100 W/m
2
780-3000 nm P
EH 1,644E+00 W/m
2
3556,56 W/m
2
380-3000 nm P
XH-CDLR-40W-X6 with CCT 5000K, COB LED, Exempt group
α=81.38mrad, Measure distant:1,3mm
Optical hazard Test result Used hazard exposure limit Ref.
Es 1,207E-07 W/m
2
0,001 W/m
2
200-400 nm P
EUVA 2,868E-03 W/m
2
0,33 W/m
2
315-400 nm P
LB 4,517E+01 W/m
2
sr 100 W/m
2
sr 300-700 nm P
EB (small source) -- -- 300-700 nm N/A
LR 6,885E+03 W/m
2
sr 3,441E+05 W/m
2
sr 380-1400 nm P
LIR 0,000E+00 W/m
2
sr 7,373E+04 W/m
2
sr 780-1400 nm P
EIR 1,817E-04 W/m
2
100 W/m
2
780-3000 nm P
EH 1,572E+00 W/m
2
3556,56 W/m
2
380-3000 nm P
www.tuv.com
Page 52 of 52 Report No. 17044083 001
XH-CDLR-40W-X6 with CCT 5000K, COB LED, CXA2520 Serial Exempt group
α=82.40mrad, Measure distant:1,42mm
Optical hazard Test result Used hazard exposure limit Ref.
Es 1,211E-07 W/m
2
0,001 W/m
2
200-400 nm P
EUVA 2,922E-03 W/m
2
0,33 W/m
2
315-400 nm P
LB 4,66E+01 W/m
2
sr 100 W/m
2
sr 300-700 nm P
EB (small source) -- -- 300-700 nm N/A
LR 7,800E+03 W/m
2
sr 3,420E+05 W/m
2
sr 380-1400 nm P
LIR 0,000E+00 W/m
2
sr 7,367E+04 W/m
2
sr 780-1400 nm P
EIR 1,00E-04 W/m
2
100 W/m
2
780-3000 nm P
EH 1,93E+00 W/m
2
3556,56 W/m
2
380-3000 nm P
XH-CDLR-40W-X6 with CCT 5000K, COB LED, CLL032 Serial Serial Exempt group
α=80.32mrad, Measure distant:1,11mm
Optical hazard Test result Used hazard exposure limit Ref.
Es 1,00E-07 W/m
2
0,001 W/m
2
200-400 nm P
EUVA 1,09E-03 W/m
2
0,33 W/m
2
315-400 nm P
LB 3,009E+01 W/m
2
sr 100 W/m
2
sr 300-700 nm P
EB (small source) -- -- 300-700 nm N/A
LR 6,299E+03 W/m
2
sr 3,876E+05 W/m
2
sr 380-1400 nm P
LIR 0,000E+00 W/m
2
sr 7,367E+04 W/m
2
sr 780-1400 nm P
EIR 1,09E-04 W/m
2
100 W/m
2
780-3000 nm P
EH 1,08E+00 W/m
2
3556,56 W/m
2
380-3000 nm P

Contenu connexe

Tendances

SLIM-SM-June 14-38423522
SLIM-SM-June 14-38423522SLIM-SM-June 14-38423522
SLIM-SM-June 14-38423522Chinthaka Asiri
 
Diesel Locomotive Shed, North Western Railway
Diesel Locomotive Shed, North Western RailwayDiesel Locomotive Shed, North Western Railway
Diesel Locomotive Shed, North Western Railway123jaya
 
F iso-17025
F iso-17025F iso-17025
F iso-17025Ahmedjet
 
ISO17025 Accreditation Procedures and Process
ISO17025 Accreditation Procedures and Process ISO17025 Accreditation Procedures and Process
ISO17025 Accreditation Procedures and Process Abdul Rahman
 
Fttx fiber-count-planning-calculation
Fttx fiber-count-planning-calculationFttx fiber-count-planning-calculation
Fttx fiber-count-planning-calculationKarthik Govin
 
Who Is Hindering Growth
Who Is Hindering GrowthWho Is Hindering Growth
Who Is Hindering GrowthGaurav Narula
 

Tendances (7)

SLIM-SM-June 14-38423522
SLIM-SM-June 14-38423522SLIM-SM-June 14-38423522
SLIM-SM-June 14-38423522
 
Modern Telecommunication ... The Very Basic.
Modern Telecommunication ... The Very Basic.Modern Telecommunication ... The Very Basic.
Modern Telecommunication ... The Very Basic.
 
Diesel Locomotive Shed, North Western Railway
Diesel Locomotive Shed, North Western RailwayDiesel Locomotive Shed, North Western Railway
Diesel Locomotive Shed, North Western Railway
 
F iso-17025
F iso-17025F iso-17025
F iso-17025
 
ISO17025 Accreditation Procedures and Process
ISO17025 Accreditation Procedures and Process ISO17025 Accreditation Procedures and Process
ISO17025 Accreditation Procedures and Process
 
Fttx fiber-count-planning-calculation
Fttx fiber-count-planning-calculationFttx fiber-count-planning-calculation
Fttx fiber-count-planning-calculation
 
Who Is Hindering Growth
Who Is Hindering GrowthWho Is Hindering Growth
Who Is Hindering Growth
 

En vedette

KäYtäNnöN Asioita Ja Turvallisuuteen Liittyvää SäHköOppia
KäYtäNnöN Asioita Ja Turvallisuuteen Liittyvää SäHköOppiaKäYtäNnöN Asioita Ja Turvallisuuteen Liittyvää SäHköOppia
KäYtäNnöN Asioita Ja Turvallisuuteen Liittyvää SäHköOppiaSanna Brauer
 
CB_IEC62133- 2500MAH
CB_IEC62133- 2500MAHCB_IEC62133- 2500MAH
CB_IEC62133- 2500MAHJames yan
 
Luminaires – Module 2 Technical Aspects
Luminaires – Module 2  Technical AspectsLuminaires – Module 2  Technical Aspects
Luminaires – Module 2 Technical AspectsMike Pitcher
 
BIS Test Report of Mobile Adapter For India Market
BIS Test Report of Mobile Adapter For India MarketBIS Test Report of Mobile Adapter For India Market
BIS Test Report of Mobile Adapter For India MarketHuaJin (Bonace Group Charger
 
IEC 60950-1 Test Report
IEC 60950-1 Test ReportIEC 60950-1 Test Report
IEC 60950-1 Test ReportMarquez Tang
 
Fairburn, GA Wastewater Treatment Plant Project
Fairburn, GA Wastewater Treatment Plant ProjectFairburn, GA Wastewater Treatment Plant Project
Fairburn, GA Wastewater Treatment Plant ProjectBenjamin Moss, E.I.T.
 
City of Las Vegas Wastewater Treatment Plant Inspection
City of Las Vegas Wastewater Treatment Plant InspectionCity of Las Vegas Wastewater Treatment Plant Inspection
City of Las Vegas Wastewater Treatment Plant InspectionChrys Djatche de Kamgaing
 
PP10 startup manual (Unofficial as Requested)
PP10 startup manual (Unofficial as Requested)PP10 startup manual (Unofficial as Requested)
PP10 startup manual (Unofficial as Requested)Muhammad Gulzar
 
AUTOMATED PRODUCTION OF MCB REPORT (Repaired) (1)
AUTOMATED PRODUCTION OF MCB REPORT (Repaired) (1)AUTOMATED PRODUCTION OF MCB REPORT (Repaired) (1)
AUTOMATED PRODUCTION OF MCB REPORT (Repaired) (1)Ankit Kumar
 
Borang assesment ict form 4
Borang assesment ict form 4Borang assesment ict form 4
Borang assesment ict form 4cikguchaen
 
ZMPCZM016000.13.03 Certificate of compliance
ZMPCZM016000.13.03 Certificate of complianceZMPCZM016000.13.03 Certificate of compliance
ZMPCZM016000.13.03 Certificate of compliancepainezeeman
 
157882189 commissioning checklist3.11.10
157882189 commissioning checklist3.11.10157882189 commissioning checklist3.11.10
157882189 commissioning checklist3.11.10bijumt
 
MBA Internship report - Customer Awareness and Market potential of geographi...
MBA Internship report -  Customer Awareness and Market potential of geographi...MBA Internship report -  Customer Awareness and Market potential of geographi...
MBA Internship report - Customer Awareness and Market potential of geographi...Santanu Das
 
06 procedure of start up boiler ok
06 procedure of start up boiler ok06 procedure of start up boiler ok
06 procedure of start up boiler okBunk Bonk
 
Aramco inspection handbook
Aramco inspection handbookAramco inspection handbook
Aramco inspection handbookram111eg
 

En vedette (18)

32 lcd cb report
32 lcd cb report32 lcd cb report
32 lcd cb report
 
KäYtäNnöN Asioita Ja Turvallisuuteen Liittyvää SäHköOppia
KäYtäNnöN Asioita Ja Turvallisuuteen Liittyvää SäHköOppiaKäYtäNnöN Asioita Ja Turvallisuuteen Liittyvää SäHköOppia
KäYtäNnöN Asioita Ja Turvallisuuteen Liittyvää SäHköOppia
 
CB_IEC62133- 2500MAH
CB_IEC62133- 2500MAHCB_IEC62133- 2500MAH
CB_IEC62133- 2500MAH
 
Absorption Trenches and Beds for Drought Gardening
Absorption Trenches and Beds for Drought GardeningAbsorption Trenches and Beds for Drought Gardening
Absorption Trenches and Beds for Drought Gardening
 
Luminaires – Module 2 Technical Aspects
Luminaires – Module 2  Technical AspectsLuminaires – Module 2  Technical Aspects
Luminaires – Module 2 Technical Aspects
 
BIS Test Report of Mobile Adapter For India Market
BIS Test Report of Mobile Adapter For India MarketBIS Test Report of Mobile Adapter For India Market
BIS Test Report of Mobile Adapter For India Market
 
Oil testing cat 2003 149-v02
Oil testing cat 2003 149-v02Oil testing cat 2003 149-v02
Oil testing cat 2003 149-v02
 
IEC 60950-1 Test Report
IEC 60950-1 Test ReportIEC 60950-1 Test Report
IEC 60950-1 Test Report
 
Fairburn, GA Wastewater Treatment Plant Project
Fairburn, GA Wastewater Treatment Plant ProjectFairburn, GA Wastewater Treatment Plant Project
Fairburn, GA Wastewater Treatment Plant Project
 
City of Las Vegas Wastewater Treatment Plant Inspection
City of Las Vegas Wastewater Treatment Plant InspectionCity of Las Vegas Wastewater Treatment Plant Inspection
City of Las Vegas Wastewater Treatment Plant Inspection
 
PP10 startup manual (Unofficial as Requested)
PP10 startup manual (Unofficial as Requested)PP10 startup manual (Unofficial as Requested)
PP10 startup manual (Unofficial as Requested)
 
AUTOMATED PRODUCTION OF MCB REPORT (Repaired) (1)
AUTOMATED PRODUCTION OF MCB REPORT (Repaired) (1)AUTOMATED PRODUCTION OF MCB REPORT (Repaired) (1)
AUTOMATED PRODUCTION OF MCB REPORT (Repaired) (1)
 
Borang assesment ict form 4
Borang assesment ict form 4Borang assesment ict form 4
Borang assesment ict form 4
 
ZMPCZM016000.13.03 Certificate of compliance
ZMPCZM016000.13.03 Certificate of complianceZMPCZM016000.13.03 Certificate of compliance
ZMPCZM016000.13.03 Certificate of compliance
 
157882189 commissioning checklist3.11.10
157882189 commissioning checklist3.11.10157882189 commissioning checklist3.11.10
157882189 commissioning checklist3.11.10
 
MBA Internship report - Customer Awareness and Market potential of geographi...
MBA Internship report -  Customer Awareness and Market potential of geographi...MBA Internship report -  Customer Awareness and Market potential of geographi...
MBA Internship report - Customer Awareness and Market potential of geographi...
 
06 procedure of start up boiler ok
06 procedure of start up boiler ok06 procedure of start up boiler ok
06 procedure of start up boiler ok
 
Aramco inspection handbook
Aramco inspection handbookAramco inspection handbook
Aramco inspection handbook
 

Similaire à Led downlight tuv gs test report

WTZ22F06119180L (LVD and 62778 test report).pdf
WTZ22F06119180L  (LVD and 62778 test report).pdfWTZ22F06119180L  (LVD and 62778 test report).pdf
WTZ22F06119180L (LVD and 62778 test report).pdfElaine504017
 
Motorola ap 8222 access point installation guide mn000046 a01
Motorola ap 8222 access point installation guide mn000046 a01Motorola ap 8222 access point installation guide mn000046 a01
Motorola ap 8222 access point installation guide mn000046 a01Advantec Distribution
 
LED Driver "BCR402W" | Infineon Technologies
LED Driver "BCR402W" | Infineon TechnologiesLED Driver "BCR402W" | Infineon Technologies
LED Driver "BCR402W" | Infineon TechnologiesInfineon Technologies AG
 
Motorola ap 8232 access point installation guide mn000032 a01
Motorola ap 8232 access point installation guide mn000032 a01Motorola ap 8232 access point installation guide mn000032 a01
Motorola ap 8232 access point installation guide mn000032 a01Advantec Distribution
 
LED Driver "BCR402U" - Datasheet | Infineon Technologies
LED Driver "BCR402U" - Datasheet | Infineon TechnologiesLED Driver "BCR402U" - Datasheet | Infineon Technologies
LED Driver "BCR402U" - Datasheet | Infineon TechnologiesInfineon Technologies AG
 
LED Driver "BCR401W" | Infineon Technologies
 LED Driver "BCR401W" | Infineon Technologies LED Driver "BCR401W" | Infineon Technologies
LED Driver "BCR401W" | Infineon TechnologiesInfineon Technologies AG
 
Motorola solutions ap6522 access point installation guide wi ng 5.5 version...
Motorola solutions ap6522 access point installation guide   wi ng 5.5 version...Motorola solutions ap6522 access point installation guide   wi ng 5.5 version...
Motorola solutions ap6522 access point installation guide wi ng 5.5 version...Advantec Distribution
 
PLC: Manual de usuario de PLC Micrologix1500.pdf
PLC: Manual de usuario de PLC Micrologix1500.pdfPLC: Manual de usuario de PLC Micrologix1500.pdf
PLC: Manual de usuario de PLC Micrologix1500.pdfSantiagoPabloAlberto1
 
Гидромоторы серии Apm212 Bucher Hydraulics
Гидромоторы серии Apm212 Bucher HydraulicsГидромоторы серии Apm212 Bucher Hydraulics
Гидромоторы серии Apm212 Bucher HydraulicsArve
 
Motorola solutions ap 6521 access point installation guide - wi ng 5.5 versio...
Motorola solutions ap 6521 access point installation guide - wi ng 5.5 versio...Motorola solutions ap 6521 access point installation guide - wi ng 5.5 versio...
Motorola solutions ap 6521 access point installation guide - wi ng 5.5 versio...Advantec Distribution
 
Motorola solutions ap6522 m access point installation guide wing 5.5 versio...
Motorola solutions ap6522 m access point installation guide   wing 5.5 versio...Motorola solutions ap6522 m access point installation guide   wing 5.5 versio...
Motorola solutions ap6522 m access point installation guide wing 5.5 versio...Advantec Distribution
 
LED Driver "BCR401U"| Infineon Technologies
LED Driver "BCR401U"| Infineon TechnologiesLED Driver "BCR401U"| Infineon Technologies
LED Driver "BCR401U"| Infineon TechnologiesInfineon Technologies AG
 

Similaire à Led downlight tuv gs test report (20)

Ce Report of usc-hs21ti hall water flow sensor from iSentrol
Ce Report of usc-hs21ti hall water flow sensor from iSentrolCe Report of usc-hs21ti hall water flow sensor from iSentrol
Ce Report of usc-hs21ti hall water flow sensor from iSentrol
 
WTZ22F06119180L (LVD and 62778 test report).pdf
WTZ22F06119180L  (LVD and 62778 test report).pdfWTZ22F06119180L  (LVD and 62778 test report).pdf
WTZ22F06119180L (LVD and 62778 test report).pdf
 
Motorola ap 8222 access point installation guide mn000046 a01
Motorola ap 8222 access point installation guide mn000046 a01Motorola ap 8222 access point installation guide mn000046 a01
Motorola ap 8222 access point installation guide mn000046 a01
 
EMC report.pdf
EMC report.pdfEMC report.pdf
EMC report.pdf
 
LED Driver "BCR402W" | Infineon Technologies
LED Driver "BCR402W" | Infineon TechnologiesLED Driver "BCR402W" | Infineon Technologies
LED Driver "BCR402W" | Infineon Technologies
 
Motorola ap 8232 access point installation guide mn000032 a01
Motorola ap 8232 access point installation guide mn000032 a01Motorola ap 8232 access point installation guide mn000032 a01
Motorola ap 8232 access point installation guide mn000032 a01
 
LED Driver "BCR402U" - Datasheet | Infineon Technologies
LED Driver "BCR402U" - Datasheet | Infineon TechnologiesLED Driver "BCR402U" - Datasheet | Infineon Technologies
LED Driver "BCR402U" - Datasheet | Infineon Technologies
 
LED Driver "BCR401W" | Infineon Technologies
 LED Driver "BCR401W" | Infineon Technologies LED Driver "BCR401W" | Infineon Technologies
LED Driver "BCR401W" | Infineon Technologies
 
Motorola solutions ap6522 access point installation guide wi ng 5.5 version...
Motorola solutions ap6522 access point installation guide   wi ng 5.5 version...Motorola solutions ap6522 access point installation guide   wi ng 5.5 version...
Motorola solutions ap6522 access point installation guide wi ng 5.5 version...
 
TXR_HF_Manual.pdf
TXR_HF_Manual.pdfTXR_HF_Manual.pdf
TXR_HF_Manual.pdf
 
Manual de PLC Micrologix 1500
Manual de PLC Micrologix 1500 Manual de PLC Micrologix 1500
Manual de PLC Micrologix 1500
 
PLC: Manual de usuario de PLC Micrologix1500.pdf
PLC: Manual de usuario de PLC Micrologix1500.pdfPLC: Manual de usuario de PLC Micrologix1500.pdf
PLC: Manual de usuario de PLC Micrologix1500.pdf
 
Manual de PLC Micrologix 1500.pdf
Manual de PLC Micrologix 1500.pdfManual de PLC Micrologix 1500.pdf
Manual de PLC Micrologix 1500.pdf
 
Гидромоторы серии Apm212 Bucher Hydraulics
Гидромоторы серии Apm212 Bucher HydraulicsГидромоторы серии Apm212 Bucher Hydraulics
Гидромоторы серии Apm212 Bucher Hydraulics
 
Manual de PLC Micrologix 1200
Manual de PLC Micrologix 1200Manual de PLC Micrologix 1200
Manual de PLC Micrologix 1200
 
Motorola solutions ap 6521 access point installation guide - wi ng 5.5 versio...
Motorola solutions ap 6521 access point installation guide - wi ng 5.5 versio...Motorola solutions ap 6521 access point installation guide - wi ng 5.5 versio...
Motorola solutions ap 6521 access point installation guide - wi ng 5.5 versio...
 
Motorola solutions ap6522 m access point installation guide wing 5.5 versio...
Motorola solutions ap6522 m access point installation guide   wing 5.5 versio...Motorola solutions ap6522 m access point installation guide   wing 5.5 versio...
Motorola solutions ap6522 m access point installation guide wing 5.5 versio...
 
Vortex flow meter catalog
Vortex flow meter catalogVortex flow meter catalog
Vortex flow meter catalog
 
LED Driver "BCR401U"| Infineon Technologies
LED Driver "BCR401U"| Infineon TechnologiesLED Driver "BCR401U"| Infineon Technologies
LED Driver "BCR401U"| Infineon Technologies
 
Radiometric measuring technology-Gammapilot FTG20
Radiometric measuring technology-Gammapilot FTG20Radiometric measuring technology-Gammapilot FTG20
Radiometric measuring technology-Gammapilot FTG20
 

Plus de John Zuo TUV GS LED light john.zuo88@gmail.com

Plus de John Zuo TUV GS LED light john.zuo88@gmail.com (20)

Xinghuo f1 integrated led track light catalogue
Xinghuo f1 integrated  led track light catalogueXinghuo f1 integrated  led track light catalogue
Xinghuo f1 integrated led track light catalogue
 
How to choose track light from xinghuo
How to choose track light from xinghuoHow to choose track light from xinghuo
How to choose track light from xinghuo
 
2019 xinghuo dali led track light catalogue
2019 xinghuo dali  led track light catalogue2019 xinghuo dali  led track light catalogue
2019 xinghuo dali led track light catalogue
 
CRI97 led track light
CRI97 led track lightCRI97 led track light
CRI97 led track light
 
ultra slim led down light
ultra slim led down lightultra slim led down light
ultra slim led down light
 
Xinghuo beam angle adjustable led track light
Xinghuo beam angle adjustable led track lightXinghuo beam angle adjustable led track light
Xinghuo beam angle adjustable led track light
 
Xinghuo Anti-glare CRI97 LED Track Light
Xinghuo Anti-glare CRI97 LED Track LightXinghuo Anti-glare CRI97 LED Track Light
Xinghuo Anti-glare CRI97 LED Track Light
 
2015 xinghuo cri 97 led track light catalogue
2015 xinghuo cri 97 led track light catalogue2015 xinghuo cri 97 led track light catalogue
2015 xinghuo cri 97 led track light catalogue
 
Zig bee led light
Zig bee led lightZig bee led light
Zig bee led light
 
2015 xinghuo cri 97 led light catalogue
2015 xinghuo cri 97 led light catalogue2015 xinghuo cri 97 led light catalogue
2015 xinghuo cri 97 led light catalogue
 
2015 xinghuo led tech limited catalogues
2015 xinghuo led tech limited catalogues2015 xinghuo led tech limited catalogues
2015 xinghuo led tech limited catalogues
 
2015 xinghuo cri 97 led light catalogue
2015 xinghuo cri 97 led light catalogue2015 xinghuo cri 97 led light catalogue
2015 xinghuo cri 97 led light catalogue
 
2015 XINGHUO TUV GS LED DOWNLIGHT CATALOGUE
2015 XINGHUO TUV GS LED DOWNLIGHT CATALOGUE2015 XINGHUO TUV GS LED DOWNLIGHT CATALOGUE
2015 XINGHUO TUV GS LED DOWNLIGHT CATALOGUE
 
Waterproof LED Downlight-IP65
Waterproof LED Downlight-IP65Waterproof LED Downlight-IP65
Waterproof LED Downlight-IP65
 
Led downlight tuv gs certification
Led downlight tuv gs certificationLed downlight tuv gs certification
Led downlight tuv gs certification
 
Waterproof led panel light ip65
Waterproof led panel light ip65Waterproof led panel light ip65
Waterproof led panel light ip65
 
Waterproof led downlight ip65
Waterproof led downlight ip65Waterproof led downlight ip65
Waterproof led downlight ip65
 
CCT Changeable and dimmable LED light catalogue
CCT Changeable and dimmable LED light catalogueCCT Changeable and dimmable LED light catalogue
CCT Changeable and dimmable LED light catalogue
 
2015 xinghuo cri 97 led light catalogue
2015 xinghuo cri 97 led light catalogue2015 xinghuo cri 97 led light catalogue
2015 xinghuo cri 97 led light catalogue
 
Led downlight waterproof test
Led downlight waterproof testLed downlight waterproof test
Led downlight waterproof test
 

Dernier

Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024The Digital Insurer
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processorsdebabhi2
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonetsnaman860154
 
Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024The Digital Insurer
 
Understanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdfUnderstanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdfUK Journal
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptxHampshireHUG
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsMaria Levchenko
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024The Digital Insurer
 
Histor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slideHistor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slidevu2urc
 
08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking MenDelhi Call girls
 
Artificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsArtificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsJoaquim Jorge
 
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxFactors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxKatpro Technologies
 
GenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationGenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationMichael W. Hawkins
 
Automating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps ScriptAutomating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps Scriptwesley chun
 
Slack Application Development 101 Slides
Slack Application Development 101 SlidesSlack Application Development 101 Slides
Slack Application Development 101 Slidespraypatel2
 
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...Igalia
 
Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)wesley chun
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)Gabriella Davis
 
The Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxThe Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxMalak Abu Hammad
 
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Miguel Araújo
 

Dernier (20)

Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processors
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonets
 
Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024
 
Understanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdfUnderstanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdf
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed texts
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024
 
Histor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slideHistor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slide
 
08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men
 
Artificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsArtificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and Myths
 
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxFactors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
 
GenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationGenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day Presentation
 
Automating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps ScriptAutomating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps Script
 
Slack Application Development 101 Slides
Slack Application Development 101 SlidesSlack Application Development 101 Slides
Slack Application Development 101 Slides
 
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
 
Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)
 
The Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxThe Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptx
 
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
 

Led downlight tuv gs test report

  • 1.
  • 2. www.tuv.com Page 2 of 52 Report No. 17044083 001 TEST REPORT IEC 60598-2-2 Luminaires Part 2: Particular requirements: Section Two – Recessed luminaires Report Number. ..............................: See the cover page Date of issue ...................................: See the cover page Total number of pages.................... See the cover page Applicant’s name............................: See the cover page Address ...........................................: See the cover page Test specification: Standard..........................................: EN 60598-2-2:2012 used in conjunction with EN 60598-1: 2008 + A11: 2009 Test procedure ...............................: GS Non-standard test method………..: N/A Test Report Form No......................: IEC60598_2_2C Test Report Form(s) Originator.....: Intertek Semko AB Master TRF......................................: 2013-02 Copyright © 2013 Worldwide System for Conformity Testing and Certification of Electrotechnical Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. Test item description .....................: LED Down Light Trade Mark ......................................: None Factory.............................................: The same as appliant Model/Type reference ....................: See model list. Ratings ............................................: See model list.
  • 3. www.tuv.com Page 3 of 52 Report No. 17044083 001 Summary of testing: Tests performed (name of test and test clause): This report includes the following parts: - All clauses of EN 60598-1: 2008+A11:2009 and EN 60598-2-2: 2012. - Annex 5: European group differences and national differences - Annex 6: LED modules for general lighting —Safety specifications EN 62031: 2008+A1: 2013. - Annex 7: Photobiological safety of lamps and lamp systems were evaluated according to standard EN 62471: 2008 Testing location: Tests of EN 60598-2-2:2012 Guangzhou GRG Metrology &Test co., Ltd. No.163Ping Yun Rd.West Of HuangPu Ave.Guangzhou P.R.China Tests for EN 62471: 2008 TÜV Rheinland (Guangdong) Ltd. No.199 Kezhu Road, Guangzhou Science City 510663 Guangzhou, China Summary of compliance with National Differences: List of countries addressed: DE DE=Germany The product fulfils the requirements of EN 60598-1: 2008 + A11: 2009 and EN 60598-2-2: 2012.
  • 4. www.tuv.com Page 4 of 52 Report No. 17044083 001 TRF No. IEC60598_2_2C Copy of marking plate The artwork below may be only a draft. The use of certification marks on a product must be authorized by the respective NCBs that own these marks. Note: Other models have the similar marking label; only model name and parameter are different. (labels of first column can be stick on body of LED Down light , labels of second column can be stick on packing of LED Down light)
  • 5. www.tuv.com Page 5 of 52 Report No. 17044083 001 TRF No. IEC60598_2_2C
  • 6. www.tuv.com Page 6 of 52 Report No. 17044083 001 TRF No. IEC60598_2_2C Test item particulars .............................................. : Classification of installation and use ........................ : LED Recessed luminaire Supply Connection ................................................... : Terminal Block .................................................................................. : .................................................................................. : Possible test case verdicts: - test case does not apply to the test object............. : N/A - test object does meet the requirement................... : P (Pass) - test object does not meet the requirement............. : F (Fail) Testing..................................................................... : Date of receipt of test item ....................................... : 2014-11-07 Date (s) of performance of tests............................... : 2014-11-17 to 2014-12-19 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma / point is used as the decimal separator. Clause numbers between brackets refer to clauses in IEC 60598-1. Remark During heating test, fix the luminaire to a ceiling, a box as following cover the luminaire, a=0mm, b=c=0mm.
  • 7. www.tuv.com Page 7 of 52 Report No. 17044083 001 General product information: Product: LED Recessed luminaire Class II, IP20, ta=35C, luminaires not suitable for covering with thermally insulating material. All models have the similar construction, only model name, dimensions and LED are different. Full tests were conducted on model XH-HDLR-30W-X5, XH-CDLR-30W-X5, XH-HDLR-40W-X6, XH-CDLR-40W-X6, XH-CDLR-40W-X4 and XH-HDLR-30W-X3 except Photobiological safety. Model list: Model Input Models of LED Driver Output of LED Driver Power CCT LED quantity LED type Size Cut out XH-HDLR- 30W-X5 AC 220-240V 50/60Hz LF- GIR030YX07 50A(Z) 27-40Vdc 750mA 30W 2700-6500K 60Pcs SMD5630 Φ230x80mm Φ195mm XH-HDLR- 20W-X5 AC 220-240V 50/60Hz LF- GIR022YX05 40A(Z) 27-42Vdc 540mA 20W 2700-6500K 48Pcs SMD5630 Φ 190*H60mm Φ160MM XH-HDLR- 15W-X5 AC 220-240V 50/60Hz LF- GIR015YX03 80A(Z) 27-42Vdc 380mA 15W 2700-6500K 36 Pcs SMD5630 Φ 145mm*H60 mm Φ125MM XH-HDLR- 12W-X5 AC 220-240V 50/60Hz LF- GIR010YX02 50A(Z) 27-42Vdc 250mA 12W 2700-6500K 24 Pcs SMD5630 Φ 145mm*H60 mm Φ125MM XH-CDLR- 30W-X5 AC 220-240V 50/60Hz LF- GIR030YX07 50A(Z) 27-40Vdc 750mA 30W 2700-5000K 1 Pcs COB Φ230x80mm Φ195mm XH-CDLR- 20W-X5 AC 220-240V 50/60Hz LF- GIR022YX05 40A(Z) 27-42Vdc 540mA 20W 2700-5000K 1 Pcs COB Φ 190*H60mm Φ160MM
  • 8. www.tuv.com Page 8 of 52 Report No. 17044083 001 TRF No. IEC60598_2_2C XH-CDLR- 15W-X5 AC 220-240V 50/60Hz LF- GIR015YX03 80A(Z) 27-42Vdc 380mA 15W 2700-5000K 1 Pcs COB Φ 145mm*H60 mm Φ125MM XH-CDLR- 12W-X5 AC 220-240V 50/60Hz LF- GIR010YX02 50A(Z) 27-42Vdc 250mA 12W 2700-5000K 1 Pcs COB Φ 145mm*H60 mm Φ125MM XH-HDLR- 40W-X6 AC 220-240V 50/60Hz LF- GIR040YX10 00A(Z) 27-42Vdc 1000mA 40W 2700-6500K 84Pcs SMD5630 Φ240x80mm Φ220mm XH-HDLR- 30W-X6 AC 220-240V 50/60Hz LF- GIR030YX07 50A(Z) 27-40Vdc 750mA 30W 2700-6500K 60Pcs SMD5630 Φ240x80mm Φ220mm XH-HDLR- 20W-X6 AC 220-240V 50/60Hz LF- GIR022YX05 40A(Z) 27-42Vdc 540mA 20W 2700-6500K 48Pcs SMD5630 Φ190x80mm Φ180mm XH-HDLR- 15W-X6 AC 220-240V 50/60Hz LF- GIR015YX03 80A(Z) 27-42Vdc 380mA 15W 2700-6500K 36 Pcs SMD5630 Φ 166*H80mm Φ150mm XH-HDLR- 12W-X6 AC 220-240V 50/60Hz LF- GIR010YX02 50A(Z) 27-42Vdc 250mA 12W 2700-6500K 24 Pcs SMD5630 Φ130x70mm Φ120mm XH-CDLR- 40W-X6 AC 220-240V 50/60Hz LF- GIR040YX10 00A(Z) 27-42Vdc 1000mA 40W 2700-5000K 1 Pcs COB Φ240x80mm Φ220mm
  • 9. www.tuv.com Page 9 of 52 Report No. 17044083 001 TRF No. IEC60598_2_2C XH-CDLR- 30W-X6 AC 220-240V 50/60Hz LF- GIR030YX07 50A(Z) 27-40Vdc 750mA 30W 2700-5000K 1 Pcs COB Φ240x80mm Φ220mm XH-CDLR- 20W-X6 AC 220-240V 50/60Hz LF- GIR022YX05 40A(Z) 27-42Vdc 540mA 20W 2700-5000K 1 Pcs COB Φ190x80mm Φ180mm XH-CDLR- 15W-X6 AC 220-240V 50/60Hz LF- GIR015YX03 80A(Z) 27-42Vdc 380mA 15W 2700-5000K 1 Pcs COB Φ 166*H80mm Φ150mm XH-CDLR- 12W-X6 AC 220-240V 50/60Hz LF- GIR010YX02 50A(Z) 27-42Vdc 250mA 12W 2700-5000K 1 Pcs COB Φ130x70mm Φ120mm XH-CDLR- 40W-X4 AC 220-240V 50/60Hz LF- GIR040YX10 00A(Z) 27-42Vdc 1000mA 40W 2700-5000K 1 Pcs COB Ф 180mm*H130 mm Φ145mm XH-CDLR- 30W-X4 AC 220-240V 50/60Hz LF- GIR030YX07 50A(Z) 27-40Vdc 750mA 30W 2700-5000K 1 Pcs COB Ф 142mm*H118 mm Φ110mm XH-CDLR- 20W-X4 AC 220-240V 50/60Hz LF- GIR022YX05 40A(Z) 27-42Vdc 540mA 20W 2700-5000K 1 Pcs COB Ф 142mm*H118 mm Φ110mm XH-CDLR- 15W-X4 AC 220-240V 50/60Hz LF- GIR015YX03 80A(Z) 27-42Vdc 380mA 15W 2700-5000K 1 Pcs COB Ф 119mm*H103 mm Φ90mm
  • 10. www.tuv.com Page 10 of 52 Report No. 17044083 001 TRF No. IEC60598_2_2C XH-CDLR- 12W-X4 AC 220-240V 50/60Hz LF- GIR010YX02 50A(Z) 27-42Vdc 250mA 12W 2700-5000K 1 Pcs COB Ф 113mm*H88 mm Φ80mm XH-HDLR- 30W-X3 AC 220-240V 50/60Hz LF- GIR030YX07 50A(Z) 27-40Vdc 750mA 30W 2700-6500K 60Pcs SMD5630 Ф 230mm*H48 mm Φ200mm XH-HDLR- 20W-X3 AC 220-240V 50/60Hz LF- GIR022YX05 40A(Z) 27-42Vdc 540mA 20W 2700-6500K 48Pcs SMD5630 Ф 190mm*H48 mm Φ170mm XH-HDLR- 15W-X3 AC 220-240V 50/60Hz LF- GIR015YX03 80A(Z) 27-42Vdc 380mA 15W 2700-6500K 36 Pcs SMD5630 Ф 180mm*H42 mm Φ150mm XH-HDLR- 12W-X3 AC 220-240V 50/60Hz LF- GIR010YX02 50A(Z) 27-42Vdc 250mA 12W 2700-6500K 24 Pcs SMD5630 Ф 140mm*H42 mm Φ120mm
  • 11. www.tuv.com Page 11 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C 2.3 (0) GENERAL TEST REQUIREMENTS P 2.3 (0.1) Information for luminaire design considered Standard Yes No  2.3 (0.3) More sections applicable ........................................: Yes No  2.5 (2) CLASSIFICATION P 2.5 (2.2) Type of protection ................................................ : Class II  2.5 (2.3) Degree of protection............................................. : IP20  2.5 (2.4) Luminaire suitable for direct mounting on normally flammable surfaces .............................................. : Yes No  2.5 (2.5) Luminaire for normal use ..................................... : Yes No  Luminaire for rough service ................................. : Yes No  2.6 (3) MARKING P 2.6 (3.2) Mandatory markings P Position of the marking P Format of symbols/text See marking plate P 2.6 (3.3) Additional information P Language of instructions English and German P 2.6 (3.3.1) Combination luminaires N/A 2.6 (3.3.2) Nominal frequency in Hz 50/60Hz P 2.6 (3.3.3) Operating temperature N/A 2.6 (3.3.4) Symbol or warning notice N/A 2.6 (3.3.5) Wiring diagram N/A 2.6 (3.3.6) Special conditions N/A 2.6 (3.3.7) Metal halide lamp luminaire – warning N/A 2.6 (3.3.8) Limitation for semi-luminaires N/A 2.6 (3.3.9) Power factor and supply current N/A 2.6 (3.3.10) Suitability for use indoors N/A 2.6 (3.3.11) Luminaires with remote control N/A 2.6 (3.3.12) Clip-mounted luminaire – warning N/A
  • 12. www.tuv.com Page 12 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C 2.6 (3.3.13) Specifications of protective shields N/A 2.6 (3.3.14) Symbol for nature of supply N/A 2.6 (3.3.15) Rated current of socket outlet N/A 2.6 (3.3.16) Rough service luminaire N/A 2.6 (3.3.17) Mounting instruction for type Y, type Z and some type X attachments N/A 2.6 (3.3.18) Non-ordinary luminaires with PVC cable N/A 2.6 (3.3.19) Protective conductor current in instruction if applicable N/A 2.6 (3.3.20) Provided with information if not intended to be mounted within arm’s reach N/A 2.6 (3.4) Test with water 15s P Test with hexane 15s P Legible after test P Label attached P 2.7 (4) CONSTRUCTION P 2.7 (4.2) Components replaceable without difficulty N/A 2.7 (4.3) Wireways smooth and free from sharp edges P 2.7 (4.4) Lampholders N/A 2.7 (4.4.1) Integral lampholder N/A 2.7 (4.4.2) Wiring connection N/A 2.7 (4.4.3) Lampholder for end-to-end mounting N/A 2.7 (4.4.4) Positioning N/A - pressure test (N) ................................................ : N/A After test the lampholder comply with relevant standard sheets and show no damage N/A After test on single-capped lampholder the lampholder have not moved from its position and show no permanent deformation N/A - bending test (N) ................................................. : N/A After test the lampholder have not moved from its position and show no permanent deformation N/A
  • 13. www.tuv.com Page 13 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C 2.7 (4.4.5) Peak pulse voltage N/A 2.7 (4.4.6) Centre contact N/A 2.7 (4.4.7) Parts in rough service luminaires resistant to tracking N/A 2.7 (4.4.8) Lamp connectors N/A 2.7 (4.4.9) Caps and bases correctly used N/A 2.7 (4.5) Starter holders N/A Starter holder in luminaires other than class II N/A Starter holder class II construction N/A 2.7 (4.6) Terminal blocks N/A Tails N/A Unsecured blocks N/A 2.7 (4.7) Terminals and supply connections P 2.7 (4.7.1) Contact to metal parts P 2.7 (4.7.2) Test 8 mm live conductor P Test 8 mm earth conductor N/A 2.7 (4.7.3) Terminals for supply conductors P 2.7 (4.7.3.1) Welded connections: N/A - stranded or solid conductor N/A - spot welding N/A - welding between wires N/A - Type Z attachment N/A - mechanical test according to 15.8.2 N/A - electrical test according to 15.9 N/A - heat test according to 15.9.2.3 and 15.9.2.4 N/A 2.7 (4.7.4) Terminals other than supply connection P 2.7 (4.7.5) Heat-resistant wiring/sleeves N/A 2.7 (4.7.6) Multi-pole plug N/A - test at 30 N N/A 2.7 (4.8) Switches: N/A
  • 14. www.tuv.com Page 14 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C - adequate rating N/A - adequate fixing N/A - polarized supply N/A - compliance with 61058-1 for electronic switches N/A 2.7 (4.9) Insulating lining and sleeves N/A 2.7 (4.9.1) Retainement N/A Method of fixing .................................................... : N/A 2.7 (4.9.2) Insulated linings and sleeves N/A Resistant to a temperature > 20 C to the wire temperature or N/A a) & c) Insulation resistance and electric strength N/A b) Ageing test. Temperature (C) ......................... : N/A 2.7 (4.10) Insulation of Class II luminaires P 2.7 (4.10.1) No contact, mounting surface – accessible metal parts – wiring of basic insulation P Safe installation fixed luminaires P Capacitors and switches N/A Interference suppression capacitors according to IEC 60384-14 N/A 2.7 (4.10.2) Assembly gaps: P - not coincidental N/A - no straight access with test probe P 2.7 (4.10.3) Retainment of insulation: N/A - fixed N/A - unable to be replaced; luminaire inoperative N/A - sleeves retained in position N/A - lining in lampholder N/A 2.7 (4.11) Electrical connections P 2.7 (4.11.1) Contact pressure P 2.7 (4.11.2) Screws: N/A - self-tapping screws N/A
  • 15. www.tuv.com Page 15 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C - thread-cutting screws N/A 2.7 (4.11.3) Screw locking: N/A - spring washer N/A - rivets N/A 2.7 (4.11.4) Material of current-carrying parts P 2.7 (4.11.5) No contact to wood or mounting surface P 2.7 (4.11.6) Electro-mechanical contact systems For connector P 2.7 (4.12) Mechanical connections and glands N/A 2.7 (4.12.1) Screws not made of soft metal P Screws of insulating material N/A Torque test: torque (Nm); part .............................. : Screw for fixing cord anchorage: 0,5Nm for all test models P Torque test: torque (Nm); part .............................. : Screw for fixing LED Module : max.0,5Nm for all test models P Torque test: torque (Nm); part .............................. : Screw for fixing LED Cover: Max.1,2Nm for all test models P 2.7 (4.12.2) Screws with diameter < 3 mm screwed into metal N/A 2.7 (4.12.4) Locked connections: N/A - fixed arms; torque (Nm)...................................... : N/A - lampholder; torque (Nm)..................................... : N/A - push-button switches; torque 0,8 Nm................. : N/A 2.7 (4.12.5) Screwed glands; force (Nm) ................................. : N/A 2.7 (4.13) Mechanical strength P 2.7 (4.13.1) Impact tests: P - fragile parts; energy (Nm)................................... : N/A - other parts; energy (Nm) .................................... : 0,35 Nm for all test models P 1) live parts P 2) linings N/A 3) protection P 4) covers P
  • 16. www.tuv.com Page 16 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C 2.7 (4.13.3) Straight test finger P 2.7 (4.13.4) Rough service luminaires N/A - IP54 or higher N/A a) fixed N/A b) hand-held N/A c) delivered with a stand N/A d) for temporary installations and suitable for mounting on a stand N/A 2.7 (4.13.6) Tumbling barrel N/A 2.7 (4.14) Suspensions and adjusting devices P 2.7 (4.14.1) Mechanical load: P A) four times the weight Max.1,3×4 =5,2 Kg for 1 hours P B) torque 2,5 Nm N/A C) bracket arm; bending moment (Nm)................ : N/A D) load track-mounted luminaires N/A E) clip-mounted luminaires, glass-shelve. Thickness (mm) ................................................... : N/A Metal rod. diameter (mm) .................................... : N/A Fixed luminaire or independent control gear without fixing devices N/A 2.7 (4.14.2) Load to flexible cables N/A Mass (kg) ............................................................. : N/A Stress in conductors (N/mm²) .............................. : N/A Mass (kg) of semi-luminaire ................................. : N/A Bending moment (Nm) of semi-luminaire ............ : N/A 2.7 (4.14.3) Adjusting devices: P - flexing test; number of cycles ............................. : 45 Cycles P - strands broken P - electric strength test afterwards P 2.7 (4.14.4) Telescopic tubes: cords not fixed to tube; no strain on conductors N/A
  • 17. www.tuv.com Page 17 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C 2.7 (4.14.5) Guide pulleys N/A 2.7 (4.14.6) Strain on socket-outlets N/A 2.7 (4.15) Flammable materials: P - glow-wire test 650 C For LED cover P - spacing  30 mm N/A - screen withstanding test of 13.3.1 N/A - screen dimensions N/A - no fiercely burning material P - thermal protection N/A - electronic circuits exempted N/A 2.7 (4.15.2) Luminaires made of thermoplastic material with lamp control gear N/A a) construction N/A b) temperature sensing control N/A c) surface temperature N/A 2.7 (4.16) Luminaires for mounting on normally flammable surfaces P No lamp control gear (compliance with Section 12) N/A 2.7 (4.16.1) Lamp control gear spacing: N/A - spacing 35 mm N/A - spacing 10 mm N/A 2.7 (4.16.2) Thermal protection: N/A - in lamp control gear N/A - external N/A - fixed position N/A - temperature marked lamp control gear N/A 2.7 (4.16.3) Design to satisfy the test of 12.6 (see 12.6) N/A 2.7 (4.17) Drain holes N/A Clearance at least 5 mm N/A 2.7 (4.18) Resistance to corrosion: N/A 2.7 (4.18.1) - rust-resistance N/A 2.7 (4.18.2) - season cracking in copper N/A
  • 18. www.tuv.com Page 18 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C 2.7 (4.18.3) - corrosion of aluminium N/A 2.7 (4.19) Ignitors compatible with ballast N/A 2.7 (4.20) Rough service vibration N/A 2.7 (4.21) Protective shield: N/A 2.7 (4.21.1) Shield fitted N/A Shield of glass if tungsten halogen lamps N/A 2.7 (4.21.2) Particles from a shattering lamp not impair safety N/A 2.7 (4.21.3) No direct path N/A 2.7 (4.21.4) Impact test on shield N/A Glow-wire test on lamp compartment N/A 2.7 (4.22) Attachments to lamps N/A 2.7 (4.23) Semi-luminaires comply Class II N/A 2.7 (4.24) UV radiation for tungsten halogen lamps and metal halide lamps (Annex P) N/A 2.7 (4.25) No sharp point or edges P 2.7 (4.26) Short-circuit protection: N/A 2.7 (4.26.1) Uninsulated accessible SELV parts N/A 2.7 (4.26.2) Short-circuit test N/A 2.7 (4.26.3) Test chain according to Figure 29 N/A 2.7 (4.27) Terminal blocks with integrated screwless earthing contacts tested according Annex V N/A Pull test of terminal fixing (20 N) N/A After test, resistance < 0,05  N/A Pull test of mechanical connection (50 N) N/A After test, resistance < 0,05  N/A Voltage drop test, resistance < 0,05  N/A 2.8 (11) CREEPAGE DISTANCES AND CLEARANCES P Working voltage (V) .............................................. : The whole luminaire consist of approved LED driver and accessible SELV LED Module 
  • 19. www.tuv.com Page 19 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C Voltage form Sinusoidal Non-sinusoidal  PTI < 600 > 600  Impulse withstand category (Normal category II) (Category III Annex U) Category II Category III  Rated pulse voltage (kV) ...................................... :  (1) Current-carrying parts of different polarity: cr (mm); cl (mm) ....................................................... : N/A (2) Current-carrying parts and accessible parts: cr (mm); cl (mm) ....................................................... : N/A (3) Parts becoming live due to breakdown of basic insulation and metal parts: cr (mm); cl (mm) ................................................... : N/A (4) Outer surface of cable where it is clamped and metal parts: cr (mm); cl (mm)................................ : N/A (6) Current-carrying parts and supporting surface: cr (mm); cl (mm) ................................................... : N/A 2.9 (7) PROVISION FOR EARTHING N/A 2.9 (7.2.1 + 7.2.3) Accessible metal parts N/A Metal parts in contact with supporting surface N/A Resistance < 0,5  ............................................... : N/A Self-tapping screws used N/A Thread-forming screws N/A Thread-forming screw used in a grove N/A Earth makes contact first N/A Terminal blocks with integrated screwless earthing contacts tested according Annex V N/A 2.9 (7.2.2 + 7.2.3) Earth continuity in joints etc. N/A 2.9 (7.2.4) Locking of clamping means N/A Compliance with 4.7.3 N/A
  • 20. www.tuv.com Page 20 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C Terminal blocks with integrated screwless earthing contacts tested according Annex V N/A 2.9 (7.2.5) Earth terminal integral part of connector socket N/A 2.9 (7.2.6) Earth terminal adjacent to mains terminals N/A 2.9 (7.2.7) Electrolytic corrosion of the earth terminal N/A 2.9 (7.2.8) Material of earth terminal N/A Contact surface bare metal N/A 2.9 (7.2.10) Class II luminaire for looping-in N/A Double or reinforced insulation to functional earth N/A 2.9 (7.2.11) Earthing core coloured green-yellow N/A Length of earth conductor N/A 2.10 (14) SCREW TERMINALS N/A Separately approved; component list (see Annex 1) N/A Part of the luminaire (see Annex 3) N/A 2.10 (15) SCREWLESS TERMINALS AND ELECTRICAL CONNECTIONS P Separately approved; component list (see Annex 1) N/A Part of the luminaire Soldered connection P 2.11 (5) EXTERNAL AND INTERNAL WIRING P 2.11 (5.2) Supply connection and external wiring P 2.11 (5.2.1) Means of connection............................................. : Terminal Block within approved LED driver P 2.11 (5.2.2) Type of cable ........................................................ : No supply cord supplied with Luminaires N/A Nominal cross-sectional area (mm²)..................... : N/A Cables equal to IEC 60227 or IEC 60245 N/A 2.11 (5.2.3) Type of attachment, X, Y or Z N/A 2.11 (5.2.5) Type Z not connected to screws N/A 2.11 (5.2.6) Cable entries: P
  • 21. www.tuv.com Page 21 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C - suitable for introduction P - adequate degree of protection P 2.11 (5.2.7) Cable entries through rigid material have rounded edges N/A 2.11 (5.2.8) Insulating bushings: N/A - suitably fixed N/A - material in bushings N/A - material not likely to deteriorate N/A - tubes or guards made of insulating material N/A 2.11 (5.2.9) Locking of screwed bushings N/A 2.11 (5.2.10) Cord anchorage: P - covering protected from abrasion P - clear how to be effective P - no mechanical or thermal stress P - no tying of cables into knots etc. P - insulating material or lining P 2.11 (5.2.10.1) Cord anchorage for type X attachment: N/A a) at least one part fixed N/A b) types of cable N/A c) no damaging of the cable N/A d) whole cable can be mounted N/A e) no touching of clamping screws N/A f) metal screw not directly on cable N/A g) replacement without special tool N/A Glands not used as anchorage N/A Labyrinth type anchorages N/A 2.11 (5.2.10.2) Adequate cord anchorage for type Y and type Z attachment N/A 2.11 (5.2.10.3) Tests: P - impossible to push cable; unsafe P
  • 22. www.tuv.com Page 22 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C - pull test: 25 times; pull (N).................................. : 60N P - torque test: torque (Nm) ..................................... : 0,15Nm P - displacement  2 mm 0,5mm P - no movement of conductors P - no damage of cable or cord P 2.11 (5.2.11) External wiring passing into luminaire N/A 2.11 (5.2.12) Looping-in terminals N/A 2.11 (5.2.13) Wire ends not tinned P Wire ends tinned: no cold flow N/A 2.11 (5.2.14) Mains plug same protection N/A Class III luminaire plug N/A 2.11 (5.2.16) Appliance inlets (IEC 60320) N/A Appliance couplers of class II type N/A 2.11 (5.2.17) No standardized interconnecting cables properly assembled N/A 2.11 (5.2.18) Used plug in accordance with N/A - IEC 60083 N/A - other standard N/A 2.11 (5.3) Internal wiring P 2.11 (5.3.1) Internal wiring of suitable size and type (see Annex 1) P Through wiring N/A - not delivered/ mounting instruction N/A - factory assembled N/A - socket outlet loaded (A)...................................... : N/A - temperatures ...................................................... : (see Annex 2) N/A Green-yellow for earth only N/A 2.11 (5.3.1.1) Internal wiring connected directly to fixed wiring P Cross-sectional area (mm²) .................................. : P Insulation thickness N/A Extra insulation added where necessary N/A 2.11 (5.3.1.2) Internal wiring connected to fixed wiring via internal current-limiting device N/A
  • 23. www.tuv.com Page 23 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C Adequate cross-sectional area and insulation thickness N/A 2.11 (5.3.1.3) Double or reinforced insulation for class II P 2.11 (5.3.1.4) Conductors without insulation N/A 2.11 (5.3.1.5) SELV current-carrying parts P 2.11 (5.3.1.6) Insulation thickness other than PVC or rubber N/A 2.11 (5.3.2) Sharp edges etc. P No moving parts of switches etc. N/A Joints, raising/lowering devices N/A Telescopic tubes etc. N/A No twisting over 360 P 2.11 (5.3.3) Insulating bushings: N/A - suitable fixed N/A - material in bushings N/A - material not likely to deteriorate N/A - cables with protective sheath N/A 2.11 (5.3.4) Joints and junctions effectively insulated N/A 2.11 (5.3.5) Strain on internal wiring N/A 2.11 (5.3.6) Wire carriers N/A 2.11 (5.3.7) Wire ends not tinned P Wire ends tinned: no cold flow N/A 2.12 (8) PROTECTION AGAINST ELECTRIC SHOCK P 2.12 (8.2.1) Live parts not accessible P Basic insulated parts not used on the outer surface without appropriate protection P Basic insulated parts not accessible with standard test finger on portable and adjustable luminaires N/A Basic insulated parts not accessible with Ø 50 mm probe from outside, within arm’s reach, on wall-mounted luminaires N/A
  • 24. www.tuv.com Page 24 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C Lamp and starterholders in portable and adjustable luminaires comply with double or reinforced insulation requirements N/A Basic insulation only accessible under lamp or starter replacement N/A Protection in any position P Double-ended tungsten filament lamp N/A Insulation lacquer not reliable N/A Double-ended high pressure discharge lamp N/A Relevant warning according to 3.2.18 fitted to the luminaire N/A 2.12 (8.2.2) Portable luminaire adjusted in most unfavourable position N/A 2.12 (8.2.3.a) Class II luminaire: P - basic insulated metal parts not accessible during starter or lamp replacement N/A - basic insulation not accessible other than during starter or lamp replacement P - glass protective shields not used as supplementary insulation N/A 2.12 (8.2.3.b) BC lampholder of metal in class I luminaires shall be earthed N/A 2.12 (8.2.3.c) Class III luminaires with exposed SELV parts: P Ordinary luminaire: P - touch current ...................................................... : N/A - no-load voltage ................................................... : Max. 50V P Other than ordinary luminaire: N/A - nominal voltage ................................................. : N/A 2.12 (8.2.4) Portable luminaire have protection independent of supporting surface N/A 2.12 (8.2.5) Compliance with the standard test finger or relevant probe P 2.12 (8.2.6) Covers reliably secured N/A 2.12 (8.2.7) Discharging of capacitors  0,5 F Approved LED Driver N/A
  • 25. www.tuv.com Page 25 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C Portable plug connected luminaire with capacitor N/A Other plug connected luminaire with capacitor N/A Discharge device on or within capacitor N/A Discharge device mounted separately N/A 2.13 (12) ENDURANCE TEST AND THERMAL TEST P 2.13 (-) If IP > IP 20 relevant test of (12.4), (12.5) and (12.6) after (9.2) before (9.3) specified in 2.14  2.13 (12.3) Endurance test: P - mounting-position ............................................... : On the black testing box  - test temperature (C).......................................... : 45C  - total duration (h) ................................................. : 240h  - supply voltage: Un factor; calculated voltage (V): 264V  - lamp used ........................................................... : LED Module  2.13 (12.3.2) After endurance test: P - no part unserviceable P - luminaire not unsafe P - no damage to track system N/A - marking legible P - no cracks, deformation etc. P 2.13 (12.4) Thermal test (normal operation) (see Annex 2) P 2.13 (12.5) Thermal test (abnormal operation) (see Annex 2) N/A 2.13 (12.6) Thermal test (failed lamp control gear condition): N/A 2.13 (12.6.1) Through wiring or looping-in wiring loaded by a current of (A) ........................................................ :  - case of abnormal conditions............................... :  - electronic lamp control gear N/A - measured winding temperature (C): at 1,1 Un . :  - measured mounting surface temperature (C) at 1,1 Un ................................................................... : N/A - calculated mounting surface temperature (C) .. : N/A
  • 26. www.tuv.com Page 26 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C - track-mounted luminaires N/A 2.13 (12.6.2) Temperature sensing control N/A - case of abnormal conditions............................... :  - thermal link N/A - manual reset cut-out N/A - auto reset cut-out N/A - measured mounting surface temperature (C)... : N/A - track-mounted luminaires N/A 2.13 (12.7) Thermal test (failed lamp control gear in plastic luminaires): N/A 2.13 (12.7.1) Luminaire without temperature sensing control N/A 2.13 (12.7.1.1) Luminaire with fluorescent lamp ≤ 70W N/A Test method 12.7.1.1 or Annex W ....................... :  Test according to 12.7.1.1: N/A - case of abnormal conditions  - Ballast failure at supply voltage (V) ................... :  - Components retained in place after the test N/A - Test with standard test finger after the test N/A Test according to Annex W: N/A - case of abnormal conditions  - measured winding temperature (C): at 1,1 Un.. :  - measured temperature of fixing point/exposed part (C): at 1,1 Un................................................ :  - calculated temperature of fixing point/exposed part (C) ................................................................ :  Ball-pressure test: N/A - part tested; temperature (C).............................. : N/A - part tested; temperature (C).............................. : N/A 2.13 (12.7.1.2) Luminaire with discharge lamp, fluorescent lamp > 70W, transformer > 10 VA N/A - case of abnormal conditions 
  • 27. www.tuv.com Page 27 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C - measured winding temperature (C): at 1,1 Un.. :  - measured temperature of fixing point/exposed part (C): at 1,1 Un................................................ :  - calculated temperature of fixing point/exposed part (C) ................................................................ :  Ball-pressure test: N/A - part tested; temperature (C).............................. : N/A - part tested; temperature (C).............................. : N/A 2.13 (12.7.1.3) Luminaire with short circuit proof transformers ≤ 10 VA N/A - case of abnormal conditions  - Components retained in place after the test N/A - Test with standard test finger after the test N/A 2.13 (12.7.2) Luminaire with temperature sensing control N/A - thermal link Yes No  - manual reset cut-out Yes No  - auto reset cut-out Yes No  - case of abnormal conditions  - highest measured temperature of fixing point/exposed part (C):........................................ :  Ball-pressure test: N/A - part tested; temperature (C).............................. : N/A - part tested; temperature (C).............................. : N/A 2.13.1 (-) Wiring, for connection to the supply, not reach unsafe temperature N/A - measured temperature of the cable (C) ........... : N/A 2.14 (9) RESISTANCE TO DUST, SOLID OBJECTS AND MOISTURE P 2.14 (-) If IP > IP 20 the order of the test specified in clause 2.13  2.14 (9.2) Tests for ingress of dust, solid objects and moisture: P - classification according to IP .............................. : IP20  - mounting position during test ............................. : On the testing ceiling. 
  • 28. www.tuv.com Page 28 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C - fixing screws tightened; torque (Nm).................. :  - tests according to clauses .................................. : Clause 9.2.0  - electric strength test afterwards N/A a) no deposit in dust-proof luminaire N/A b) no talcum in dust-tight luminaire N/A c) no trace of water on current-carrying parts or SELV parts or where it could become a hazard N/A d) i) For luminaires without drain holes – no water entry N/A d) ii) For luminaires with drain holes – no hazardous water entry N/A e) no water in watertight luminaire N/A f) no contact with live parts (IP 2X) IP20 P f) no entry into enclosure (IP 3X and IP 4X) N/A f) no contact with live parts (IP3X and IP4X) N/A g) no trace of water on part of lamp requiring protection from splashing water N/A h) no damage of protective shield or glass envelope N/A 2.14 (9.3) Humidity test 48 h 25C, 93%R.H. for 48 h P 2.15 (10) INSULATION RESISTANCE AND ELECTRIC STRENGTH P 2.15 (10.2.1) Insulation resistance test P Cable or cord covered by metal foil or replaced by a metal rod of mm Ø ............................................ :  Insulation resistance (M)  SELV: P - between current-carrying parts of different polarity .................................................................. : N/A - between current-carrying parts and mounting surface .................................................................. : Min99,9 G > 1 M P - between current-carrying parts and metal parts of the luminaire ..................................................... : Min99,9 G > 1 M P
  • 29. www.tuv.com Page 29 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C - between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts ................................... : N/A - Insulation bushings as described in Section 5 .. : N/A Other than SELV: P - between live parts of different polarity................ : N/A - between live parts and mounting surface........... : Min 99,9 G > 4 M P - between live parts and metal parts..................... : Min 99,9 G > 4 M P - between live parts of different polarity through action of a switch .................................................. : N/A - between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts ................................... : N/A - Insulation bushings as described in Section 5 .. : N/A 2.15 (10.2.2) Electric strength test P Dummy lamp N/A Luminaires with ignitors after 24 h test N/A Luminaires with manual ignitors N/A Test voltage (V): P SELV: P - between current-carrying parts of different polarity .................................................................. : N/A - between current-carrying parts and mounting surface .................................................................. : 500 V for all models P - between current-carrying parts and metal parts of the luminaire ..................................................... : 500 V for all models P - between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts ................................... : N/A - Insulation bushings as described in Section 5 .. : N/A Other than SELV: P - between live parts of different polarity................ : N/A - between live parts and mounting surface........... : 2960V for all models P - between live parts and metal parts..................... : 2960V for all models P
  • 30. www.tuv.com Page 30 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C - between live parts of different polarity through action of a switch .................................................. : N/A - between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts ................................... : N/A - Insulation bushings as described in Section 5 .. : N/A 2.15 (10.3) Touch current or protective conductor current (mA) ...................................................................... : Max 0,08mA P 2.16 (13) RESISTANCE TO HEAT, FIRE AND TRACKING P 2.16 (13.2.1) Ball-pressure test: P - part tested; temperature (C).............................. : connector: 125C, 0,9 mm P - part tested; temperature (C).............................. : N/A 2.16 (13.3.1) Needle flame test (10 s): N/A - part tested........................................................... : N/A - part tested........................................................... : N/A 2.16 (13.3.2) Glow-wire test (650C): P - part tested........................................................... : Connector , LED Cover P - part tested........................................................... : N/A 2.16 (13.4.1) Tracking test: N/A - part tested........................................................... : N/A - part tested........................................................... : N/A
  • 31. www.tuv.com Page 31 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C ANNEX 1: components P object/part No. cod e manufacturer/ trademark type/model technical data standar d mark(s) of conformity LED Driver (for 40W Models) B Shenzhen Ledfriend Optoelectronics Co., Ltd LF-GIR040YX1000A(Z) Independent SELV LED Driver ; Input 200-240V~, 50/60Hz, Max 0,5A; output 27- 42Vdc,1000mA; ta:40C, tc:80C -- TUV SUD B 14 05 74050 009 LED Driver (for 30W Models) B Shenzhen Ledfriend Optoelectronics Co., Ltd LF-GIR030YX0750A(Z) Independent SELV LED Driver ; Input 200-240V~, 50/60Hz, Max 0,4A; output 27- 40Vdc,750mA; ta:40C, tc:70C -- TUV SUD B 14 05 74050 009 LED Driver (for 20W Models) B Shenzhen Ledfriend Optoelectronics Co., Ltd LF-GIR022YX0540A(Z) Independent SELV LED Driver ; Input 200-240V~, 50/60Hz, Max 0,3A; output 27- 42Vdc,540mA; ta:40C, tc:70C -- TUV SUD B 14 05 74050 009 LED Driver (for 15W Models) B Shenzhen Ledfriend Optoelectronics Co., Ltd LF-GIR015YX0380A(Z) Independent SELV LED Driver ; Input 200-240V~, 50/60Hz, Max 0,2A; output 27- 42Vdc,380mA; ta:40C, tc:70C -- TUV SUD B 14 05 74050 009 LED Driver (for 12W Models) B Shenzhen Ledfriend Optoelectronics Co., Ltd LF-GIR010YX0250A(Z) Independent SELV LED Driver ; Input 200-240V~, 50/60Hz, Max 0,2A; output 27- 42Vdc, 250mA; ta:40C, tc:70C -- TUV SUD B 14 05 74050 009
  • 32. www.tuv.com Page 32 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C Output wire B,C HUMEN XINTAI ELECTRICAL WIRES FACTORY 2464 18AWG,VW- 1,300V -- Test with appliance LED Cover B,C HUIZHOU BOYU TECHNOLOGY CO LTD AL-01-P EP -- Test with appliance Connector B,C XingdeElectroni cs., LTD 5,5X2,1 220V,4A -- Test with appliance LED(SMD) B,C Samsung LM561B(5630) 150mA, 2,7Vdc-3,2Vdc 2700K-6500K -- Test with appliance LED(COB) B,C CREE INC CXA2530 Serial 800mA, 37,9Vdc-42Vdc 2700K-5000K -- Test with appliance (Alternative) COB D CREE INC CXA1512 Serial 350mA, 38Vdc-42Vdc 2700K-5000K -- Test with appliance (Alternative) COB D CREE INC CXA1816 Serial Max.900mA, 37Vdc 2700K-5000K -- Test with appliance (Alternative) COB D CREE INC CXA1507 Serial 750mA or 375mA 18Vdc or 37Vdc 2700K-5000K -- Test with appliance (Alternative) COB D CREE INC CXA2520 Serial 550mA-1250mA, 36Vdc-42Vdc 2700K-5000K -- Test with appliance
  • 33. www.tuv.com Page 33 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C (Alternative) COB D CITIZEN ELECTRONIC S CO., Ltd CLL022 Serial CLL032 Serial 36,2Vdc, 120mA or 180mA or 240mA (for CLL 022 Serial), 300mA or 360mA or 480mA or 720mA (for CLL 032 Serial), 2700K-5000K -- Test with appliance The codes above have the following meaning: A - The component is replaceable with another one, also certified, with equivalent characteristics B - The component is replaceable if authorised by the test house C - Integrated component tested together with the appliance D - Alternative component
  • 34. www.tuv.com Page 34 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C ANNEX 2: temperature measurements, thermal tests of Section 12 P Type reference .....................................................: XH-HDLR-40W-X6  Lamp used............................................................: LED module  Lamp control gear used .......................................: Mode: LF-GIR040YX1000A(Z) Input: 220-240V~, 50/60Hz; Output: 27V-42VDC, 1000mA; Max.ouput:50Vdc; tc=80ºC.  Mounting position of luminaire .............................: On the black ceiling  Supply wattage (W)..............................................: 37,4 W  Supply current (A) ................................................: 0,183 A  Calculated power factor .......................................: -----  Table: measured temperatures corrected for ta =35C: - abnormal operating mode..................................: Short-circuit of LED driver output.  - test 1: rated voltage ...........................................: N/A  - test 2: 1,06 times rated voltage or 1,05 times rated wattage........................................................: 254,4V  - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage ............: N/A  - test 4: 1,1 times rated voltage or 1,05 times rated wattage........................................................: N/A  Through wiring or looping-in wiring loaded by a current of A during the test ..................................: N/A  temperature (C) of part Clause 12.4 – normal Clause 12.5 – abnormal test 1 test 2 test 3 limit test 4 limit Supply wire -- 49,9ºC -- Ref. -- -- Outside surface of LED driver (tc) -- 69,7ºC -- 80,0ºC -- -- Output wire -- 56,7ºC -- 90,0ºC -- -- Connector 45,9ºC Ref. Wire to LED -- 66,7ºC -- 90,0ºC -- -- LED PCB -- 67,9ºC -- Ref. -- --
  • 35. www.tuv.com Page 35 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C LED Cover -- 64,1ºC -- Ref. -- -- Inside recessed box -- 61,1ºC -- 90,0ºC -- -- Light object(0,1 m) -- 47,5ºC -- 90,0ºC -- -- Mounting surface -- 52,3ºC -- 90,0ºC -- -- Type reference .....................................................: XH-HDLR-30W-X5  Lamp used............................................................: LED module  Lamp control gear used .......................................: Mode: LF-GIR030YX0750A(Z) Input: 220-240V~, 50/60Hz; Output: 27V-40VDC, 750mA; Max.ouput:50Vdc; tc=70ºC.  Mounting position of luminaire .............................: On the black ceiling  Supply wattage (W)..............................................: 30,1 W  Supply current (A) ................................................: 0,125 A  Calculated power factor .......................................: -----  Table: measured temperatures corrected for ta =35C: - abnormal operating mode..................................: Short-circuit of LED driver output.  - test 1: rated voltage ...........................................: N/A  - test 2: 1,06 times rated voltage or 1,05 times rated wattage........................................................: 254,4V  - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage ............: N/A  - test 4: 1,1 times rated voltage or 1,05 times rated wattage........................................................: N/A  Through wiring or looping-in wiring loaded by a current of A during the test ..................................: N/A  temperature (C) of part Clause 12.4 – normal Clause 12.5 – abnormal test 1 test 2 test 3 limit test 4 limit Supply wire -- 44,6ºC -- Ref. -- -- Outside surface of LED driver (tc) -- 69,3ºC -- 70,0ºC -- -- Output wire -- 47,1ºC -- 90,0ºC -- --
  • 36. www.tuv.com Page 36 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C Connector -- 42,9ºC -- Ref. -- -- Wire to LED -- 62,3ºC -- 90,0ºC -- -- LED PCB -- 64,6ºC -- Ref. -- -- LED Cover -- 58,7ºC -- Ref. -- -- Inside recessed box -- 58,4ºC -- 90,0ºC -- -- Light object(0,1 m) -- 47,9ºC -- 90,0ºC -- -- Mounting surface -- 47,2ºC -- 90,0ºC -- -- Type reference .....................................................: XH-HDLR-30W-X3  Lamp used............................................................: LED module  Lamp control gear used .......................................: Mode: LF-GIR030YX0750A(Z) Input: 220-240V~, 50/60Hz; Output: 27V-40VDC, 750mA; Max.ouput:50Vdc; tc=70ºC  Mounting position of luminaire .............................: On the black ceiling  Supply wattage (W)..............................................: 30,1 W  Supply current (A) ................................................: 0,124 A  Calculated power factor .......................................: -----  Table: measured temperatures corrected for ta =35C: - abnormal operating mode..................................: Short-circuit of LED driver output.  - test 1: rated voltage ...........................................: N/A  - test 2: 1,06 times rated voltage or 1,05 times rated wattage........................................................: 254,4V  - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage ............: N/A  - test 4: 1,1 times rated voltage or 1,05 times rated wattage........................................................: N/A  Through wiring or looping-in wiring loaded by a current of A during the test ..................................: N/A  temperature (C) of part Clause 12.4 – normal Clause 12.5 – abnormal test 1 test 2 test 3 limit test 4 limit
  • 37. www.tuv.com Page 37 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C Supply wire -- 43,3ºC -- Ref. -- -- Outside surface of LED driver (tc) -- 69,7ºC -- 70,0ºC -- -- Output wire -- 48,3ºC -- 90,0ºC -- -- Connector -- 47,7ºC -- Ref. -- -- Wire to LED -- 65,7ºC -- 90,0ºC -- -- LED PCB -- 66,2ºC -- Ref. -- -- LED Cover -- 35,6ºC -- Ref. -- -- Inside recessed box -- 70,1ºC -- 90,0ºC -- -- Light object(0,1 m) -- 44,2ºC -- 90,0ºC -- -- Mounting surface -- 47,9ºC -- 90,0ºC -- -- Type reference .....................................................: XH-CDLR-40W-X6  Lamp used............................................................: LED module  Lamp control gear used .......................................: Mode: LF-GIR040YX1000A(Z) Input: 220-240V~, 50/60Hz; Output: 27V-42VDC, 1000mA; Max.ouput:50Vdc; tc=80ºC.  Mounting position of luminaire .............................: On the black ceiling  Supply wattage (W)..............................................: 36,1 W  Supply current (A) ................................................: 0,149 A  Calculated power factor .......................................: -----  Table: measured temperatures corrected for ta =35C: - abnormal operating mode..................................: Short-circuit of LED driver output.  - test 1: rated voltage ...........................................: N/A  - test 2: 1,06 times rated voltage or 1,05 times rated wattage........................................................: 254,4V  - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage ............: N/A  - test 4: 1,1 times rated voltage or 1,05 times rated wattage........................................................: N/A 
  • 38. www.tuv.com Page 38 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C Through wiring or looping-in wiring loaded by a current of A during the test ..................................: N/A  temperature (C) of part Clause 12.4 – normal Clause 12.5 – abnormal test 1 test 2 test 3 limit test 4 limit Supply wire -- 43,3ºC -- Ref. -- -- Outside surface of LED driver (tc) -- 69,0ºC -- 80,0ºC -- -- Output wire -- 48,7ºC -- 90,0ºC -- -- Connector -- 46,0ºC -- Ref. -- -- Wire to LED -- 66,9ºC -- 90,0ºC -- -- LED PCB -- 73,0ºC -- Ref. -- -- LED Cover -- 53,6ºC -- Ref. -- -- Inside recessed box -- 68,2ºC -- 90,0ºC -- -- Light object(0,1 m) -- 41,1ºC -- 90,0ºC -- -- Mounting surface -- 53,4ºC -- 90,0ºC -- -- Type reference .....................................................: XH-CDLR-40W-X4  Lamp used............................................................: LED module  Lamp control gear used .......................................: Mode: LF-GIR040YX1000A(Z) Input: 220-240V~, 50/60Hz; Output: 27V-42VDC, 1000mA; Max.ouput:50Vdc; tc=80ºC.  Mounting position of luminaire .............................: On the black ceiling  Supply wattage (W)..............................................: 40,8 W  Supply current (A) ................................................: 0,165 A  Calculated power factor .......................................: -----  Table: measured temperatures corrected for ta =35C: - abnormal operating mode..................................: Short-circuit of LED driver output.  - test 1: rated voltage ...........................................: N/A 
  • 39. www.tuv.com Page 39 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C - test 2: 1,06 times rated voltage or 1,05 times rated wattage........................................................: 254,4V  - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage ............: N/A  - test 4: 1,1 times rated voltage or 1,05 times rated wattage........................................................: N/A  Through wiring or looping-in wiring loaded by a current of A during the test ..................................: N/A  temperature (C) of part Clause 12.4 – normal Clause 12.5 – abnormal test 1 test 2 test 3 limit test 4 limit Supply wire -- 46,4ºC -- Ref. -- -- Outside surface of LED driver (tc) -- 69,0ºC -- 80,0ºC -- -- Output wire -- 56,2ºC -- 90,0ºC -- -- Connector -- 46,2ºC -- Ref. -- -- Wire to LED -- 74,0ºC -- 90,0ºC -- -- LED PCB -- 79,5ºC -- Ref. -- -- LED Cover -- 71,5ºC -- Ref. -- -- Inside recessed box -- 48,2ºC -- 90,0ºC -- -- Light object(0,1 m) -- 42,0ºC -- 90,0ºC -- -- Mounting surface -- 44,5ºC -- 90,0ºC -- -- Type reference .....................................................: XH-CDLR-30W-X5  Lamp used............................................................: LED module  Lamp control gear used .......................................: Mode: LF-GIR030YX0750A(Z) Input: 220-240V~, 50/60Hz; Output: 27V-40VDC, 750mA; Max.ouput:50Vdc; tc=70ºC  Mounting position of luminaire .............................: On the black ceiling  Supply wattage (W)..............................................: 28,3 W  Supply current (A) ................................................: 0,117 A  Calculated power factor .......................................: -----  Table: measured temperatures corrected for ta =35C:
  • 40. www.tuv.com Page 40 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C - abnormal operating mode..................................: Short-circuit of LED driver output.  - test 1: rated voltage ...........................................: N/A  - test 2: 1,06 times rated voltage or 1,05 times rated wattage........................................................: 254,4V  - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage ............: N/A  - test 4: 1,1 times rated voltage or 1,05 times rated wattage........................................................: N/A  Through wiring or looping-in wiring loaded by a current of A during the test ..................................: N/A  temperature (C) of part Clause 12.4 – normal Clause 12.5 – abnormal test 1 test 2 test 3 limit test 4 limit Supply wire -- 42,9ºC -- Ref. -- -- Outside surface of LED driver (tc) -- 69,7ºC -- 70,0ºC -- -- Output wire -- 46,6ºC -- 90,0ºC -- -- Connector -- 49,1ºC -- Ref. -- -- Wire to LED -- 66,2ºC -- 90,0ºC -- -- LED PCB -- 73,0ºC -- Ref. -- -- LED Cover -- 51,4ºC -- Ref. -- -- Inside recessed box -- 64,6ºC -- 90,0ºC -- -- Light object(0,1 m) -- 40,8ºC -- 90,0ºC -- -- Mounting surface -- 48,3ºC -- 90,0ºC -- -- Type reference .....................................................: XH-CDLR-20W-X4  Lamp used............................................................: LED module  Lamp control gear used .......................................: Mode: LF-GIR022YX0540A(Z) Input: 220-240V~, 50/60Hz; Output: 27V-42VDC, 540mA; Max.ouput:50Vdc; tc=70ºC  Mounting position of luminaire .............................: On the black ceiling  Supply wattage (W)..............................................: 19,9 W 
  • 41. www.tuv.com Page 41 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C Supply current (A) ................................................: 0,082 A  Calculated power factor .......................................: -----  Table: measured temperatures corrected for ta =35C: - abnormal operating mode..................................: Short-circuit of LED driver output.  - test 1: rated voltage ...........................................: N/A  - test 2: 1,06 times rated voltage or 1,05 times rated wattage........................................................: 254,4V  - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage ............: N/A  - test 4: 1,1 times rated voltage or 1,05 times rated wattage........................................................: N/A  Through wiring or looping-in wiring loaded by a current of A during the test ..................................: N/A  temperature (C) of part Clause 12.4 – normal Clause 12.5 – abnormal test 1 test 2 test 3 limit test 4 limit Supply wire -- 41,0ºC -- Ref. -- -- Outside surface of LED driver (tc) -- 60,2ºC -- 70,0ºC -- -- Output wire -- 51,1ºC -- 90,0ºC -- -- Connector -- 39,9ºC -- Ref. -- -- Wire to LED -- 65,9ºC -- 90,0ºC -- -- LED PCB -- 72,3ºC -- Ref. -- -- LED Cover -- 63,8ºC -- Ref. -- -- Inside recessed box -- 42,6ºC -- 90,0ºC -- -- Light object(0,1 m) -- 38,7ºC -- 90,0ºC -- -- Mounting surface -- 40,5ºC -- 90,0ºC -- -- Type reference .....................................................: XH-CDLR-15W-X4  Lamp used............................................................: LED module 
  • 42. www.tuv.com Page 42 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C Lamp control gear used .......................................: Mode: LF-GIR015YX0380A(Z) Input: 220-240V~, 50/60Hz; Output: 27V-42VDC, 380mA; Max.ouput:50Vdc; tc=70ºC  Mounting position of luminaire .............................: On the black ceiling  Supply wattage (W)..............................................: 15,2 W  Supply current (A) ................................................: 0,063 A  Calculated power factor .......................................: -----  Table: measured temperatures corrected for ta =35C: - abnormal operating mode..................................: Short-circuit of LED driver output.  - test 1: rated voltage ...........................................: N/A  - test 2: 1,06 times rated voltage or 1,05 times rated wattage........................................................: 254,4V  - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage ............: N/A  - test 4: 1,1 times rated voltage or 1,05 times rated wattage........................................................: N/A  Through wiring or looping-in wiring loaded by a current of A during the test ..................................: N/A  temperature (C) of part Clause 12.4 – normal Clause 12.5 – abnormal test 1 test 2 test 3 limit test 4 limit Supply wire -- 39,8ºC -- Ref. -- -- Outside surface of LED driver (tc) -- 57,3ºC -- 70,0ºC -- -- Output wire -- 50,0ºC -- 90,0ºC -- -- Connector -- 38,1ºC -- Ref. -- -- Wire to LED -- 60,9ºC -- 90,0ºC -- -- LED PCB -- 68,7ºC -- Ref. -- -- LED Cover -- 59,9ºC -- Ref. -- -- Inside recessed box -- 38,6ºC -- 90,0ºC -- -- Light object(0,1 m) -- 37,1ºC -- 90,0ºC -- -- Mounting surface -- 37,9ºC -- 90,0ºC -- --
  • 43. www.tuv.com Page 43 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C Type reference .....................................................: XH-CDLR-12W-X4  Lamp used............................................................: LED module  Lamp control gear used .......................................: Mode: LF-GIR010YX0250A(Z) Input: 220-240V~, 50/60Hz; Output: 27V-42VDC, 250mA; Max.ouput:50Vdc; tc=70ºC  Mounting position of luminaire .............................: On the black ceiling  Supply wattage (W)..............................................: 11,9 W  Supply current (A) ................................................: 0,049 A  Calculated power factor .......................................: -----  Table: measured temperatures corrected for ta =35C: - abnormal operating mode..................................: Short-circuit of LED driver output.  - test 1: rated voltage ...........................................: N/A  - test 2: 1,06 times rated voltage or 1,05 times rated wattage........................................................: 254,4V  - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage ............: N/A  - test 4: 1,1 times rated voltage or 1,05 times rated wattage........................................................: N/A  Through wiring or looping-in wiring loaded by a current of A during the test ..................................: N/A  temperature (C) of part Clause 12.4 – normal Clause 12.5 – abnormal test 1 test 2 test 3 limit test 4 limit Supply wire -- 38,7ºC -- Ref. -- -- Outside surface of LED driver (tc) -- 56,2ºC -- 70,0ºC -- -- Output wire -- 49,7ºC -- 90,0ºC -- -- Connector -- 37,4ºC -- Ref. -- -- Wire to LED -- 59,9ºC -- 90,0ºC -- -- LED PCB -- 66,4ºC -- Ref. -- -- LED Cover -- 58,0ºC -- Ref. -- --
  • 44. www.tuv.com Page 44 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C Inside recessed box -- 38,0ºC -- 90,0ºC -- -- Light object(0,1 m) -- 36,5ºC -- 90,0ºC -- -- Mounting surface -- 37,0ºC -- 90,0ºC -- --
  • 45. www.tuv.com Page 45 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C ANNEX 3: screw terminals (part of the luminaire) N/A (14) SCREW TERMINALS N/A (14.2) Type of terminal................................................... :  Rated current (A)................................................. :  (14.3.2.1) One or more conductors N/A (14.3.2.2) Special preparation N/A (14.3.2.3) Terminal size N/A Cross-sectional area (mm²)................................. : N/A (14.3.3) Conductor space (mm)........................................ : N/A (14.4) Mechanical tests N/A (14.4.1) Minimum distance N/A (14.4.2) Cannot slip out N/A (14.4.3) Special preparation N/A (14.4.4) Nominal diameter of thread (metric ISO thread) . : N/A External wiring N/A No soft metal N/A (14.4.5) Corrosion N/A (14.4.6) Nominal diameter of thread (mm) ....................... : N/A Torque (Nm) ........................................................ : N/A (14.4.7) Between metal surfaces N/A Lug terminal N/A Mantle terminal N/A Pull test; pull (N) .................................................. : N/A (14.4.8) Without undue damage N/A
  • 46. www.tuv.com Page 46 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C ANNEX 4: screwless terminals (part of the luminaire) N/A (15) SCREWLESS TERMINALS N/A (15.2) Type of terminal................................................... :  Rated current (A)................................................. :  (15.3.1) Material N/A (15.3.2) Clamping N/A (15.3.3) Stop N/A (15.3.4) Unprepared conductors N/A (15.3.5) Pressure on insulating material N/A (15.3.6) Clear connection method N/A (15.3.7) Clamping independently N/A (15.3.8) Fixed in position N/A (15.3.10) Conductor size N/A Type of conductor N/A (15.5.1) Terminals internal wiring N/A (15.5.1.1) Pull test spring-type terminals (4 N, 4 samples)….: N/A (15.5.1.2) Pull test pin or tab terminals (4 N, 4 samples)……: N/A Insertion force not exceeding 50 N N/A (15.5.1.2) Permanent connections: pull-off test (20 N) N/A (15.6) Electrical tests N/A Voltage drop (mV) after 1 h (4 samples)............. : N/A Voltage drop of two inseparable joints N/A Number of cycles................................................. :  Voltage drop (mV) after 10th alt. 25th cycle (4 samples).......................................................... : N/A Voltage drop (mV) after 50th alt. 100th cycle (4 samples).......................................................... : N/A
  • 47. www.tuv.com Page 47 of 52 Report No. 17044083 001 IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60598_2_2C After ageing, voltage drop (mV) after 10th alt. 25th cycle (4 samples) ........................................ : N/A After ageing, voltage drop (mV) after 50th alt. 100th cycle (4 samples) ...................................... : N/A (15.7) Terminals external wiring N/A Terminal size and rating N/A (15.8.1) Pull test spring-type terminals or welded connections (4 samples); pull (N) ....................... : N/A Pull test pin or tab terminals (4 samples); pull (N) ................................................................ : N/A (15.9) Contact resistance test N/A Voltage drop (mV) after 1 h N/A terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV) Voltage drop of two inseparable joints N/A Voltage drop after 10th alt. 25th cycle N/A Max. allowed voltage drop (mV)................ :  terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV) Voltage drop after 50th alt. 100th cycle N/A Max. allowed voltage drop (mV)................ :  terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV) Continued ageing: voltage drop after 10th alt. 25th cycle N/A Max. allowed voltage drop (mV)................ :  terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV) Continued ageing: voltage drop after 50th alt. 100th cycle N/A Max. allowed voltage drop (mV)................ :  terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV)
  • 48. www.tuv.com Page 48 of 52 Report No. 17044083 001 Annex 5: EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES Luminaires Part 2: Particular requirements: Section Two – Recessed luminaires Differences according ....................: EN 60598-2-2:2012 used in conjunction with EN 60598-1:2008 + A11:2009 Annex Form No...............................: EU_GD_IEC60598_2_2B Annex Form Originator .....................: IMQ S.p.A. Master Annex Form..........................: 2012-11 Copyright © 2012 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. CENELEC COMMON MODIFICATIONS (EN) P 2.5 (3) MARKING N/A 2.5 (3.3.101) Adequate warning on the package N/A 2.6 (4) CONSTRUCTION P 2.6 (4.11.6) Electro-mechanical contact systems P 2.10 (5) EXTERNAL AND INTERNAL WIRING N/A 2.10 (5.2.1) Connecting leads N/A - without a means for connection to the supply N/A - terminal block specified N/A - relevant information provided N/A - compliance with 4.6, 4.7.1, 4.7.2, 4.10.1, 11.2, 12 and 13.2 of Part 1 N/A 2.10 (5.2.2) Cables equal to HD21 S2 or HD22 S2 N/A 2.12 (12) ENDURANCE TEST AND THERMAL TEST P 2.12 (12.4.2c) Thermal test (normal operation) P ZB ANNEX ZB, SPECIAL NATIONAL CONDITIONS (EN) N/A (3.3) DK: power supply cord with label N/A IT: warning label on Class 0 luminaire N/A
  • 49. www.tuv.com Page 49 of 52 Report No. 17044083 001 Annex 5: EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES (4.5.1) DK: socket-outlets N/A (5.2.1) CY, DK, FI, SE, GB: type of plug N/A ZC ANNEX ZC, NATIONAL DEVIATIONS (EN) N/A (4 & 5) FR: Shuttered socket-outlets 10/16A N/A (13.3) FR: Glow-wire test 850C alt. 750C for luminaires in premises open to public or 960°C for luminaires in emergency exits N/A (13.3) GB: Requirements according to United Kingdom Building Regulation N/A
  • 50. www.tuv.com Page 50 of 52 Report No. 17044083 001 Annex 6 LED modules for general lighting —Safety specifications EN 62031: 2008+ A1:2013 P Clause Requirement – Test Result - Remark Verdict 13.2 Module withstands overpower condition >15 min. P Module with automatic protective device or power limiter, test performed 15 min. at limit. P During the tests, tissue paper, spread below module, does not ignite P 14 Conformity testing during manufacture Tested as a part of luminaire P 17 Screws, current-carrying parts and connections P The requirements of IEC 61347-1, Clause 17, apply. P
  • 51. www.tuv.com Page 51 of 52 Report No. 17044083 001 Annex 7 Photobiological safety of lamps and lamp systems were according to standard EN 62471:2008 and EU Directive 2006/25/EC. Exempt group, this classification applied for all models P XH-HDLR-40W-X6 with CCT 6500K, SMD5630 LED , Exempt group α=100,00mrad, Measure distant:1,3mm Optical hazard Test result Used hazard exposure limit Ref. Es 1,386E-07 W/m 2 0,001 W/m 2 200-400 nm P EUVA 3,295E-03 W/m 2 0,33 W/m 2 315-400 nm P LB 3,002E+01 W/m 2 sr 100 W/m 2 sr 300-700 nm P EB (small source) -- -- 300-700 nm N/A LR 4,185E+02 W/m 2 sr 2.800E+05 W/m 2 sr 380-1400 nm P LIR 1,780E-02 W/m 2 sr 6.000E+04 W/m 2 sr 780-1400 nm P EIR 0,000E+00 W/m 2 100 W/m 2 780-3000 nm P EH 1,644E+00 W/m 2 3556,56 W/m 2 380-3000 nm P XH-CDLR-40W-X6 with CCT 5000K, COB LED, Exempt group α=81.38mrad, Measure distant:1,3mm Optical hazard Test result Used hazard exposure limit Ref. Es 1,207E-07 W/m 2 0,001 W/m 2 200-400 nm P EUVA 2,868E-03 W/m 2 0,33 W/m 2 315-400 nm P LB 4,517E+01 W/m 2 sr 100 W/m 2 sr 300-700 nm P EB (small source) -- -- 300-700 nm N/A LR 6,885E+03 W/m 2 sr 3,441E+05 W/m 2 sr 380-1400 nm P LIR 0,000E+00 W/m 2 sr 7,373E+04 W/m 2 sr 780-1400 nm P EIR 1,817E-04 W/m 2 100 W/m 2 780-3000 nm P EH 1,572E+00 W/m 2 3556,56 W/m 2 380-3000 nm P
  • 52. www.tuv.com Page 52 of 52 Report No. 17044083 001 XH-CDLR-40W-X6 with CCT 5000K, COB LED, CXA2520 Serial Exempt group α=82.40mrad, Measure distant:1,42mm Optical hazard Test result Used hazard exposure limit Ref. Es 1,211E-07 W/m 2 0,001 W/m 2 200-400 nm P EUVA 2,922E-03 W/m 2 0,33 W/m 2 315-400 nm P LB 4,66E+01 W/m 2 sr 100 W/m 2 sr 300-700 nm P EB (small source) -- -- 300-700 nm N/A LR 7,800E+03 W/m 2 sr 3,420E+05 W/m 2 sr 380-1400 nm P LIR 0,000E+00 W/m 2 sr 7,367E+04 W/m 2 sr 780-1400 nm P EIR 1,00E-04 W/m 2 100 W/m 2 780-3000 nm P EH 1,93E+00 W/m 2 3556,56 W/m 2 380-3000 nm P XH-CDLR-40W-X6 with CCT 5000K, COB LED, CLL032 Serial Serial Exempt group α=80.32mrad, Measure distant:1,11mm Optical hazard Test result Used hazard exposure limit Ref. Es 1,00E-07 W/m 2 0,001 W/m 2 200-400 nm P EUVA 1,09E-03 W/m 2 0,33 W/m 2 315-400 nm P LB 3,009E+01 W/m 2 sr 100 W/m 2 sr 300-700 nm P EB (small source) -- -- 300-700 nm N/A LR 6,299E+03 W/m 2 sr 3,876E+05 W/m 2 sr 380-1400 nm P LIR 0,000E+00 W/m 2 sr 7,367E+04 W/m 2 sr 780-1400 nm P EIR 1,09E-04 W/m 2 100 W/m 2 780-3000 nm P EH 1,08E+00 W/m 2 3556,56 W/m 2 380-3000 nm P