SlideShare une entreprise Scribd logo
1  sur  50
Télécharger pour lire hors ligne
TONGOU Electrical is one of the most specialized manufacturers and
exports for modular electric terminal devices for household,commerical,
industrial and similar installations in china. The wide range products
under manufacturing covers Miniature Citcuit Breaker(MCB), Residual
Current Circuit Breaker(RCCB), Residual Current Circuit Breakers with
Overcurrent Protection(RCBO), Switch- disconnector, Distribution Box,
Moulded case circuit breaker(MCCB), air circuit breaker(ACB), AC
Contactor, Magnetic Starter, Motor Protection Circuit Breaker and
Thermal Relay etc. The company takes the reputation as one of the
largest manufacturer of electromagnetic type RCCB and RCBO. OEM
or ODM projects are fully accepted, and currently the company is co-
operating with numbers of renowned international corporations for such
project.
In order to create distinguished achievement,we insist on “3S” “SAFE
with (Warranty, qualification, fully tested), SAVE with ( Time, Cost,
Energy), Smile with(Service,Future, Attitude)”
TONGOU Electrical possesses full line of high-tech production equip-
ment and great strength of technology support besides advanced des-
ignation forces powered by the first class engineering teams with su-
per industrial computer systems. Thus, our products are novel in
design, excellent in workmanship and top reliable in quality.
Experience in manufacturing under customers design, trade, biding
project, OEM and competitive cooperation related to the new prod-
ucts & technology. Won approvals of CE, SEMKO, CB, CCC and
ISO9001 Quality System Certificate etc. Products being popular around
the world, such as Europe, America, Southeast Asia, Middle East,
Africa, etc.
www.elcb.net
www.chinatongou.com
About
TONGOU
TONGOU poroducts are certified by the following international certificates:
International Germany Germany Sweden EU Netheland USA Argentina China
Miniature
Circuit
Breaker
A
Residual
Current
Circuit
Breaker
B
Residual
Current Circuit
Breaker with
Overcurrent
Protection
C
Disconnector
Switch
D
Contactor
&
Thermal
Relay
E
Moulded
Case Circuit
Breaker
F
Distribution
Box
G
CONTENTS
A01-44
B01-24
C01-09
D01-05
E01-43
F01-23
G01-06
Standrad: IEC 60898
Miniature Circuit Breaker
Miniature
Circuit
Breaker
A TOMP1-32 Miniature Circuit Breaker ...........................
TOMPG-32 Miniature Circuit Breaker ..........................
TOMP10-32 Miniature Circuit Breaker .........................
TOMP11-32 Miniature Circuit Breaker ..........................
TOM10-100 Miniature Circuit Breaker ..........................
TOM65-100Miniature Circuit Breaker ...........................
TOMG1-100 Miniature Circuit Breaker .........................
TOML1-100 Miniature Circuit Breaker ..........................
TOMS1-100 Miniature Circuit Breaker .........................
Miniature Circuit Breaker Electrical Accessories ..........
Modular Indicator ..........................................................
TOPI-1 Plug-in Miniature Circuit Breakers ........................
TOPI-2 Plug-in Miniature Circuit Breakers ........................
TOPI-3 Plug-in Miniature Circuit Breakers ........................
TOPI-4 Plug-in Miniature Circuit Breakers ........................
TOPI-5 Plug-in Miniature Circuit Breakers ........................
TOPI-M Plug-in Miniature Circuit Breakers .......................
TOPI-6 Plug-in Miniature Circuit Breakers ........................
TOPI-7 Plug-in Miniature Circuit Breakers ......................
TOPI-8 Plug-in Miniature Circuit Breakers ....................
TOPI-9 Plug-in Miniature Circuit Breakers .......................
TOPI-10 Plug-in Miniature Circuit Breakers ..................
TOMT-50 Miniature Circuit Breaker ..............................
A-23
A-24
A-25
A-25
A-26
A-27
A-28
A-29
A-30
A-31
A-32
A-33
A-34
A-35
A-36
A-37
A-38
A-39
A-40
A-41
A-42
A-43
A-44
TOMN1-63 Miniature Circuit Breaker .......................
TOMC1-63 Miniature Circuit Breaker .......................
TOMC2-63 Miniature Circuit Breaker .......................
TOMC3-63 Miniature Circuit Breaker .......................
TOM71-63 Miniature Circuit Breaker .......................
TOM72-63 Miniature Circuit Breaker .......................
TOM7B-63Miniature Circuit Breaker .......................
TOMHW-63(3KA) Miniature Circuit Breaker .............
TOMHU-63(6KA) Miniature Circuit Breaker .............
TOMHC-63 Miniature Circuit Breaker .....................
TOMHT-63 Miniature Circuit Breaker ......................
TOMHB-63 Miniature Circuit Breaker ......................
TOM10-63 Miniature Circuit Breaker .......................
TOM11-63 Miniature Circuit Breaker .......................
TOM12-63 Miniature Circuit Breaker .......................
TOM65-63 Miniature Circuit Breaker .......................
TOMG1-63 Miniature Circuit Breaker .....................
TOML1-63 Miniature Circuit Breaker .......................
TOML2-63 Miniature Circuit Breaker .......................
TOM30-63 Miniature Circuit Breaker .......................
TOMS1-63 Miniature Circuit Breaker .....................
TOMS2-63 Miniature Circuit Breaker .....................
TOMS3-63 Miniature Circuit Breaker .....................
A-01
A-02
A-03
A-04
A-05
A-06
A-07
A-08
A-08
A-09
A-10
A-11
A-12
A-13
A-14
A-15
A-16
A-17
A-18
A-19
A-20
A-21
A-22
Standrad: IEC 60898
Miniature Circuit Breaker
MCB is applicable to electric circuits with rated voltage 230/400V AC, frequency 50/60Hz and rated current
up to 125Amp. The product provides protection against voerload and short circuit to electric circuits and
equipments in household and commercial installation. MCB is also used as non-frequent changeover of
electric circuits.
Special tips:
1. MCB is for non-professional operation by those untrained, and no maintenance is required
2. Satisfying conditions and applications as mentioned above,MCB with “ON-OFF” indicating device is
considered suitable for isolation function.
3. Particular devices such as surge protective devices,surge arrester etc are recommended to install at
upstream line to MCB as precaution against potential surge voltage and current occurring at its power
input side.
4. Appropriate tripping curve being chosen and properly installed, MCB trips and switches off its protected
circuit in case of fault, and thus provides protection against electric shock.
5. B,C,D tripping curve(see graphics 1):
B cure:
=Instantaneous tripping current:5In
=Instantaneous non-tripping current:3In
=Application:provides protection to circuits with low inductive load
C curve:
=Instantaneous tripping current:10In
=Instantaneous non-tripping current:5In
=Application:provides protection to circuits
with inductive load or to highly inductive
illumination system
D curve:
=Instantaneous tripping current: 20In
=Instantaneous non-tripping current:10In
=Application:provides protection to
circuits with high inductive load or
electric distribution system with high
surge current
6. Ambient temperature and current rating curve
GENERAL
Miniature
Circuit
Breaker
Http://www.elcb.net
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=The state-of-art design
=Elegant appearance;cover and handle in arc shape make comfortable operation.
=Contact position indicating window
=Transparent cover designed to carry label.
=Handle central-staying function for circuit fault indicating
=In case of overload, to protect circuit,MCB handle trips and stays at central position, which enables
a quick solution to the faulty line. The handle cannot stay in such position when operated manually.
=High short-circuit capacity
=High short-circuit capacity 6KA for whole range and 10kA capacity for current rating up to 40A
thanks to the powerful electric arc extinguishing system.
=Long electrical endurance up to 6000 cycles thanks to quick making mechanism.
=Handle padlock device
=MCB handle can be locked either at “ON” position or at “OFF” position to prevent unwanted operation
of the product.
=Screw terminal lock device
=The lock device prevents unwanted or casual dismounting of connected terminals.
Overall & Installation Dimensions
Technical Data
=Pole No: 1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve: B,C,D
=Rated short-circuit capacity(lcn): 6kA
=Rated service short-circuit breaking capacity(lcs): 7.5kA
=Rated frequency: 50/60Hz
=Energy limiting class: 3
=Rated impulse withstand voltage: 6.2kV
=Electro-mechanical endurance: 8000
=Contact positon indication
=Connection terminal:
=Screw terminal
=Pillar terminal with clamp
=Connection capacity: Rigid conductor up to 25mm2
=Fastening torque: 2.0Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
TOMN1-63
A-01
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Contact position indication
=Applicable to terminal and pin/fork type busbar connection
=Easy mounting onto 35mm DIN rail
Overall & Installation Dimensions
Technical Data
=Pole No:1,2,3,4
=Rated voltage:AC 230/400V
=Rated current(A):1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve:B,C,D
=Rated short-circuit capacity(lcn):6kA
=Rated frequency:50/60Hz
=Energy limiting calss:3
=Rated impulse withstand voltage:6.2kV
=Electro-mechanical endurance: 6000
=Contact position indication
=Connection terminal:
=Screw terminal
=Pillar terminal with calmp
=Connection capacity:Rigid conductor up to 25mm2
=Fastening torque:2.0Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
TOMC1-63
Miniature
CircuitBreaker
A-02
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Contact position indication
=Applicable to terminal and pin/fork type busbar connection
=Easy mounting onto 35mm DIN rail
Technical Data
=Pole No:1,2,3,4
=Rated voltage:AC 230/400V
=Rated current(A):1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve:B,C,D
=Rated short-circuit capacity(lcn):6kA
=Rated frequency:50/60Hz
=Energy limiting calss:3
=Rated impulse withstand voltage:6.2kV
=Electro-mechanical endurance: 6000
=Contact position indication
=Connection terminal:
=Screw terminal
=Pillar terminal with calmp
=Connection capacity:Rigid conductor up to 25mm2
=Fastening torque:2.0Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
Overall & Installation Dimensions
TOMC2-63
A-03
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Contact position indication
=Applicable to terminal and pin/fork type busbar connection
=Easy mounting onto 35mm DIN rail
Overall & Installation Dimensions
Technical Data
=Pole No:1,2,3,4
=Rated voltage:AC 230/400V
=Rated current(A):1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve:B,C,D
=Rated short-circuit capacity(lcn):6kA
=Rated frequency:50/60Hz
=Energy limiting calss:3
=Rated impulse withstand voltage:6.2kV
=Electro-mechanical endurance: 6000
=Contact position indication
=Connection terminal:
=Screw terminal
=Pillar terminal with calmp
=Connection capacity:Rigid conductor up to 25mm2
=Fastening torque:2.0Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
TOMC3-63
Miniature
CircuitBreaker
A-04
Standrad: IEC 60898
Miniature Circuit Breaker
Overall & Installation Dimensions
50
66
78
17.5
35
52.5
70
81
45
35.5
Technical Data
=Pole No:1,2,3,4
=Rated voltage:AC 230/400V
=Rated current(A):1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve:B,C,D
=Rated short-circuit capacity(lcn):6kA
=Rated frequency:50/60Hz
=Energy limiting calss:3
=Rated impulse withstand voltage:6.2kV
=Electro-mechanical endurance: 6000
=Contact position indication
=Connection terminal:
=Screw terminal
=Pillar terminal with calmp
=Connection capacity:Rigid conductor up to 25mm2
=Fastening torque:2.0Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Contact position indication
=Applicable to terminal and pin/fork type busbar connection
=Easy mounting onto 35mm DIN rail
TOM71-63
A-05
Standrad: IEC 60898
Miniature Circuit Breaker
Overall & Installation Dimensions
17.5 50
66
76
35
52.5
70
80
45
36
Technical Data
=Pole No: 1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve: B,C,D
=Rated short-circuit capacity(lcn): 6kA
=Rated frequency: 50/60Hz
=Energy limiting calss: 3
=Rated impulse withstand voltage: 6.2kV
=Electro-mechanical endurance: 6000
=Contact position indication
=Connection terminal:
=Screw terminal
=Pillar terminal with calmp
=Connection capacity: Rigid conductor up to 25mm2
=Fastening torque: 2.0Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Contact position indication
=Applicable to terminal and pin/fork type busbar connection
=Easy mounting onto 35mm DIN rail
TOM72-63
Miniature
CircuitBreaker
A-06
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Contact position indication
=Applicable to terminal and pin/fork type busbar connection
=Easy mounting onto 35mm DIN rail
Overall & Installation Dimensions
18
36
54
50
80
45
35
66
72
Technical Data
=Pole No: 1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve: B,C,D
=Rated short-circuit capacity(lcn): 6kA
=Rated frequency: 50/60Hz
=Energy limiting calss: 3
=Rated impulse withstand voltage: 6.2kV
=Electro-mechanical endurance: 6000
=Contact position indication
=Connection terminal:
=Screw terminal
=Pillar terminal with calmp
=Connection capacity:Rigid conductor up to 25mm2
=Fastening torque: 2.0Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
TOM7B-63
A-07
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Applicable to terminal and pin/fork type busbar connection
=Easy mounting onto 35mm DIN rail
Overall & Installation Dimensions
=Pole No: 1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve: B,C,D
=Rated short-circuit capacity(lcn): 3kA,6kA
=Rated frequency: 50/60Hz
=Energy limiting calss: 3
=Rated impulse withstand voltage: 6.2kV
=Electro-mechanical endurance: 6000
=Connection terminal:
=Screw terminal
=Pillar terminal with calmp
=Connection capacity:Rigid conductor up to 25mm2
=Fastening torque:2.0Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
Technical Data
TOMHW-63(3KA)
TOMHU-63(6KA)
Miniature
CircuitBreaker
A-08
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Contact position indication
=Applicable to terminal and pin/fork type busbar connection
=Easy mounting onto 35mm DIN rail
Overall & Installation Dimensions
18
36
54
72
Technical Data
=Pole No: 1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve: B,C,D
=Rated short-circuit capacity(lcn): 6kA
=Rated frequency: 50/60Hz
=Energy limiting calss: 3
=Rated impulse withstand voltage: 6.2kV
=Electro-mechanical endurance: 6000
=Contact position indication
=Connection terminal:
=Screw terminal
=Pillar terminal with calmp
=Connection capacity:Rigid conductor up to 25mm2
=Fastening torque: 2.0Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
TOMHC-63
A-09
Standrad: IEC 60898
Miniature Circuit Breaker
Overall & Installation Dimensions
Technical Data
=Pole No: 1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve: B,C,D
=Rated short-circuit capacity(lcn): 6kA
=Rated frequency: 50/60Hz
=Energy limiting calss: 3
=Rated impulse withstand voltage: 6.2kV
=Electro-mechanical endurance: 6000
=Connection terminal:
=Screw terminal
=Pillar terminal with calmp
=Connection capacity: Rigid conductor up to 25mm2
=Fastening torque: 2.0Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Applicable to terminal and pin/fork type busbar connection
=Easy mounting onto 35mm DIN rail
TOMHT-63
Miniature
CircuitBreaker
A-10
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Transparent cover designed to carry label
=Applicable to terminal and pin/fork type busbar connection
=Easy mounting onto 35mm DIN rail
Overall & Installation Dimensions
Technical Data
=Pole No: 1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve: B,C,D
=Rated short-circuit capacity(lcn): 6kA
=Rated frequency: 50/60Hz
=Energy limiting calss: 3
=Rated impulse withstand voltage: 6.2kV
=Electro-mechanical endurance: 6000
=Connection terminal:
=Screw terminal
=Pillar terminal with calmp
=Connection capacity: Rigid conductor up to 25mm2
=Fastening torque: 2.0Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
TOMHB-63
A-11
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Easy mounting onto 35mm DIN rail
Overall & Installation Dimensions
Technical Data
=Pole No: 1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve: B,C,D
=Ultimate short-circuit capacity(lcu): 4.5KA
=Rated frequency: 50/60Hz
=Energy limiting class: 3
=Rated impulse withstand voltage: 6.2KV
=Electro-mechanical endurance: 4000
=Connection terminal: Pillar terminal with clamp
=Connection capacity: Rigid conductor up to 25mm2
=Fastening torque: 2.0Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
TOM10-63
Miniature
CircuitBreaker
A-12
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Easy mounting onto 35mm DIN rail
TOM11-63
A-13
Technical Data
=Pole No:1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve: B,C,D
=Rated short-circuit capacity(lcn): 6kA
=Rated frequency: 50/60Hz
=Energy limiting calss: 3
=Rated impulse withstand voltage: 6.2kV
=Electro-mechanical endurance: 6000
=Connection terminal:
=Screw terminal
=Pillar terminal with calmp
=Connection capacity:Rigid conductor up to 25mm2
=Fastening torque:2.0Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
Overall & Installation Dimensions
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Easy mounting onto 35mm DIN rail
TOM12-63
Miniature
CircuitBreaker
A-14
Overall & Installation Dimensions
Technical Data
=Pole No: 1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve: B,C,D
=Ultimate short-circuit capacity(lcu): 6KA
=Rated frequency: 50/60Hz
=Energy limiting class: 3
=Rated impulse withstand voltage: 6.2KV
=Electro-mechanical endurance: 4000
=Connection terminal: Pillar terminal with clamp
=Connection capacity: Rigid conductor up to 25mm2
=Fastening torque: 2.0Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Easy mounting onto 35mm DIN rail
TOM65-63
A-15
Technical Data
=Pole No:1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve: B,C,D
=Rated short-circuit capacity(lcn): 6kA
=Rated frequency: 50/60Hz
=Energy limiting calss: 3
=Rated impulse withstand voltage: 6.2kV
=Electro-mechanical endurance: 6000
=Connection terminal:
=Screw terminal
=Pillar terminal with calmp
=Connection capacity: Rigid conductor up to 25mm2
=Fastening torque:2.0Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
36
54
72
Overall & Installation Dimensions
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Easy mounting onto 35mm DIN rail
Overall & Installation Dimensions
TOMG1-63
Miniature
CircuitBreaker
A-16
Technical Data
=Pole No:1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve: B,C,D
=Rated short-circuit capacity(lcn): 6kA
=Rated frequency: 50/60Hz
=Energy limiting calss: 3
=Rated impulse withstand voltage: 6.2kV
=Electro-mechanical endurance: 6000
=Connection terminal:
=Screw terminal
=Pillar terminal with calmp
=Connection capacity: Rigid conductor up to 25mm2
=Fastening torque: 2.0Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
Standrad: IEC 60898
Miniature Circuit Breaker
TOML1-63
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Applicable to terminal and pin/fork type busbar connection
=Easy mounting onto 35mm DIN rail
A-17
36
54
72
Overall & Installation Dimensions
Technical Data
=Pole No: 1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve: B,C,D
=Rated short-circuit capacity(lcn): 6kA
=Rated frequency: 50/60Hz
=Energy limiting calss: 3
=Rated impulse withstand voltage: 6.2kV
=Electro-mechanical endurance: 6000
=Connection terminal:
=Screw terminal
=Pillar terminal with calmp
=Connection capacity: Rigid conductor up to 25mm2
=Fastening torque: 2.0Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Applicable to terminal and pin/fork type busbar connection
=Easy mounting onto 35mm DIN rail
Technical Data
=Pole No: 1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve: B,C,D
=Rated short-circuit capacity(lcn): 6kA
=Rated frequency: 50/60Hz
=Energy limiting calss: 3
=Rated impulse withstand voltage: 6.2kV
=Electro-mechanical endurance: 6000
=Connection terminal:
=Screw terminal
=Pillar terminal with calmp
=Connection capacity:Rigid conductor up to 25mm2
=Fastening torque: 2.0Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
TOML2-63
Miniature
CircuitBreaker
A-18
Overall & Installation Dimensions
36
54
72
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Easy mounting onto 35mm DIN rail
TOM30-63
A-19
Overall & Installation Dimensions
Technical Data
=Pole No: 1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve: B,C,D
=Ultimate short-circuit capacity(lcu): 6KA
=Rated frequency: 50/60Hz
=Energy limiting class: 3
=Rated impulse withstand voltage: 6.2KV
=Electro-mechanical endurance: 6000
=Connection terminal:
=Screw terminal
=Pillar terminal with clamp
=Connection capacity: Rigid conductor up to 25mm2
=Fastening torque: 2.0Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Applicable to terminal and pin/fork type busbar connection
=Easy mounting onto 35mm DIN rail
TOMS1-63
Miniature
CircuitBreaker
A-20
Overall & Installation Dimensions
17
34
51
78
Technical Data
=Pole No: 1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve: B,C,D
=Rated short-circuit capacity(lcn): 6kA
=Rated frequency: 50/60Hz
=Energy limiting calss: 3
=Rated impulse withstand voltage: 6.2kV
=Electro-mechanical endurance:6000
=Connection terminal:
=Screw terminal
=Pillar terminal with calmp
=Connection capacity: Rigid conductor up to 25mm2
=Fastening torque: 2.0Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Easy mounting onto 35mm DIN rail
TOMS2-63
A-21
Overall & Installation Dimensions
36
54
72
Technical Data
=Pole No:1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve: B,C,D
=Rated short-circuit capacity(lcn): 6kA
=Rated frequency: 50/60Hz
=Energy limiting calss: 3
=Rated impulse withstand voltage: 6.2kV
=Electro-mechanical endurance: 6000
=Connection terminal:
=Screw terminal
=Pillar terminal with calmp
=Connection capacity: Rigid conductor up to 25mm2
=Fastening torque: 2.0Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Easy mounting onto 35mm DIN rail
Overall & Installation Dimensions
TOMS3-63
Miniature
CircuitBreaker
A-22
Technical Data
=Pole No:1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve: B,C,D
=Rated short-circuit capacity(lcn): 6kA
=Rated frequency: 50/60Hz
=Energy limiting calss: 3
=Rated impulse withstand voltage: 6.2kV
=Electro-mechanical endurance: 6000
=Connection terminal:
=Screw terminal
=Pillar terminal with calmp
=Connection capacity: Rigid conductor up to 25mm2
=Fastening torque: 2.0Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=Protection against both overload and short circuits
=Integrated with switched phase and neutral pole
=Neutral pole provides no protection against overload and short circuits
=Easy mounting onto 35mm DIN rail
Overall & Installation Dimensions
Technical Data
=Pole No: 1P+N
=Rated voltage: AC 230
=Rated current(A): 3,6,10,16,20,25,32
=Tripping curve: C
=Rated short-circuit capacity: 6KA
=Rated service short-circuit capacity(lcs): 6KA
=Rated frequency: 50/60Hz
=Connection terminal: Pillar terminal with clamp
=Connection capacity: Rigid conductor up to 10mm2
=Fastening torque: 1.2Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
TOMP1-32
A-23
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=Protection against both overload and short circuits
=Integrated with switched phase and neutral pole
=Neutral pole provides no protection against overload and short circuits
=Easy mounting onto 35mm DIN rail
Overall & Installation Dimensions
Technical Data
=Pole No: 1P+N
=Rated voltage: AC 230
=Rated current(A): 3,6,10,16,20,25,32
=Tripping curve: C
=Rated short-circuit capacity: 6KA
=Rated service short-circuit capacity(lcs): 6KA
=Rated frequency: 50/60Hz
=Connection terminal: Pillar terminal with clamp
=Connection capacity: Rigid conductor up to 10mm2
=Fastening torque: 1.2Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
TOMPG-32
Miniature
CircuitBreaker
A-24
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=Protection against both overload and short circuits
=Integrated with switched phase and neutral pole
=Neutral pole provides no protection against overload and short circuits
=Easy mounting onto 35mm DIN rail
Overall & Installation Dimensions
Technical Data
=Pole No: 1P+N
=Rated voltage: AC 230
=Rated current(A): 3,6,10,16,20,25,32
=Tripping curve: C
=Rated short-circuit capacity: 6KA
=Rated service short-circuit capacity(lcs): 6KA
=Rated frequency: 50/60Hz
=Connection terminal: Pillar terminal with clamp
=Connection capacity: Rigid conductor up to 10mm2
=Fastening torque: 1.2Nm
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
TOMP10-32
TOMP11-32
A-25
MP10-32
MP11-32
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=High short-circuit capacity 25KA
=Designed to protect circuit carrying big current up to 125A
=Contact position indication
=Used as main switch in household and similar installation
TOM10-100
Miniature
CircuitBreaker
A-26
Overall & Installation Dimensions
Technical Data
=Pole No: 1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 20,25,32,40,50,63,80,100,125
=Tripping curve: C,D
=Ultimate short-circuit breaking capacity(lcu): 25KA
=Service short-circuit breaking capacity(lcs): 15KA
=Rated frequency: 50/60Hz
=Rated impulse withstand voltage: 6KV
=Electro-mechanical endurance: In 100=10000; In125=8000
=Connection terminal: Pillar terminal with clamp
=Connection capacity:
=Flexible conductor 35mm2
=Rigid conductor 50mm2
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Easy mounting onto 35mm DIN rail
Overall & Installation Dimensions
Technical Data
=Pole No: 1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 20,25,32,40,50,63,80,100,125
=Tripping curve: C,D
=Ultimate short-circuit breaking capacity(lcu): 25KA
=Service short-circuit breaking capacity(lcs): 15KA
=Rated frequency: 50/60Hz
=Rated impulse withstand voltage: 6KV
=Electro-mechanical endurance: In 100=10000; In125=8000
=Connection terminal: Pillar terminal with clamp
=Connection capacity:
=Flexible conductor 35mm2
=Rigid conductor 50mm2
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
54
81
108
TOM65-100
A-27
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=High short-circuit capacity 25KA
=Designed to protect circuit carrying big current up to 125A
=Contact position indication
=Used as main switch in household and similar installation
Overall & Installation Dimensions
Technical Data
=Pole No: 1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 20,25,32,40,50,63,80,100,125
=Tripping curve: C,D
=Ultimate short-circuit breaking capacity(lcu): 25KA
=Service short-circuit breaking capacity(lcs): 15KA
=Rated frequency: 50/60Hz
=Rated impulse withstand voltage: 6KV
=Electro-mechanical endurance: In 100=10000; In125=8000
=Connection terminal: Pillar terminal with clamp
=Connection capacity:
=Flexible conductor 35mm2
=Rigid conductor 50mm2
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
TOMG1-100
Miniature
CircuitBreaker
A-28
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Easy mounting onto 35mm DIN rail
Technical Data
=Pole No: 1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 20,25,32,40,50,63,80,100,125
=Tripping curve: C,D
=Ultimate short-circuit breaking capacity(lcu): 25KA
=Service short-circuit breaking capacity(lcs): 15KA
=Rated frequency: 50/60Hz
=Rated impulse withstand voltage: 6KV
=Electro-mechanical endurance: In 100=10000; In125=8000
=Connection terminal: Pillar terminal with clamp
=Connection capacity:
=Flexible conductor 35mm2
=Rigid conductor 50mm2
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
Overall & Installation Dimensions
27
54
81
108
TOML1-100
A-29
Standrad: IEC 60898
Miniature Circuit Breaker
Construction and Feature
=High short-circuit capacity 25KA
=Designed to protect circuit carrying big current up to 125A
=Contact position indication
=Used as main switch in household and similar installation
54
81
108
Overall & Installation Dimensions
Technical Data
=Pole No: 1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 20,25,32,40,50,63,80,100,125
=Tripping curve: C,D
=Ultimate short-circuit breaking capacity(lcu): 25KA
=Service short-circuit breaking capacity(lcs): 15KA
=Rated frequency: 50/60Hz
=Rated impulse withstand voltage: 6KV
=Electro-mechanical endurance: In 100=10000; In125=8000
=Connection terminal: Pillar terminal with clamp
=Connection capacity:
=Flexible conductor 35mm2
=Rigid conductor 50mm2
=Installation:
=On symmetrical DIN rail 35mm
=Panel mounting
TOMS1-100
Miniature
CircuitBreaker
A-30
Standrad: IEC 60898
Miniature Circuit BreakerMiniature Circuit Breaker
Electrical Accessories
Specification
Q Undervoltage Auxiliary Switch
G Overvoltage Auxiliary Switch
VAC
Mx+Of Shunt Triper Auxiliary
Switch
MN Under-Voltage Auxiliary
Switch
Model
OF Auxiliary Switch
SD Alarm Auxiliary Switch
MX Shunt Triper
QG Over-/Under-Voltage Auxiliary Switch
VDC
VDC
VAC
VAC
VAC
VDC
VAC
VDC
VAC
VAC
VDC
Rated Voltage (V) Rated Current (A) Installing Size
(Times of 9mm Width)
415V
-
125V
-
-
415V°´
-
125V
-
-
220-415V°´
24-48V
220-415V°´
110-220V°´
24-48V
12-24V
220-415V°´
110-220V°´
24-48V
12-24V
170V±5%
280V±5%
170V±5%
280V±5%
-...
-...
-...
-...
-...
TOM10-63
-...
-...
1
2
2
2
2
TOM10-63 TOM65-63 TOM71-63
2
1
1
1
2
-
2
2
2
1
1
2
-
2
2
2
MX+OF SD
SD OF MX+OF
+ +
+ +
OF
SD OF MX+OF
+
+ + +
TOM71-63
+
TOM65-63
TOM10-63
=Character: Used to indicate the Off” position of circuit
breaker.
=Assembly: Installed on the left side of circuit breaker.
=Application: It’s used to indicate the fault of equipments
like the electric circuir in air-conditioning room or elevator
for passenger or goods.
SD Alarm Auxiliary Switch
Of Auxiliary Switch
=Character: Used to indicate the On ” or Off ” position
of circuit breaker.
=Assembly: Installed on the left side of circuit breaker.
=Application: Used to indicate the On”or Off ”position
of circuit breaker, the signals can be seen on the case
or its front or on the operating stage. It is can be connected
with SD alarm auxiliary switch.
MX+OF Shunt TripperR
=Character: Used for remote control tripping.
=Assembly: Installed on the right side of circuit breaker.
=Application: it’s applied to break or contact fire fighting
alarm system by remote control for electric circuit, it’s
also available for remote trip by pressing emergency
stop button. Meanwhile, it owns the same functions of
OF auxiliary switch.
A-31
TOM65-63
415V°´
230V°´
24V
48V
130V
415V°´
230V°´
24V
48V
130V
220-415V°´
24-48V
220-415V°´
110-220V°´
24-48V
12-24V
-
-
-
-
170V±5%
280V±5%
170V±5%
280V±5%
-...
-...
-...
-...
-...
-...
-...
-...
-...
TOM71-63
415V°´
230V°´
24V
48V
130V
415V°´
230V°´
24V
-
-
220-415V°´
24-48V
220-415V°´
110-220V°´
110-220V
24-60V
-
-
-
-
170V±5%
280V±5%
170V±5%
280V±5%
-...
-...
-...
-...
-...
-...
-...
44V
48V
3
3
3
44V
44V
480V
3
3
3
-
44V
44V
480V
3
3
3
-
3
-
1
-
-
3
-
1
-
-
TOM10-63 TOM65-63 TOM71-63
3
6
6
2
1
3
6
6
2
1
3
6
4
2
1
2
4
1
-
-
Standrad: IEC 60898
Miniature Circuit BreakerModular Indicator
TOIL1 TOIL2 TOIL3
TOI71TOI70 TOI72
TOI31TOIS1 TOI32
TOI10TOI12(LED) TOI11
Application
The modular signal lamp is applicable to circuit with rated voltage 230V~
and frequency 50/60Hz for visual indication and signaling.
Construction & Feature
=Low service duration, minimum power consumption
=Compact design in modular size
=Easy installation
Technical Data
=Rated voltage: 230V AC
=Rated frequency: 50/60Hz
=Colour:
=Connection terminal: pillar terminal with clamp
=Connection capacity: rigid conductor 10mm2
=Installation:
=On symmetrical DIN rail
=Panel mounting
Overall & Installation Dimensions
Miniature
CircuitBreaker
Miniature
CircuitBreaker
Miniature
CircuitBreaker
A-32
Standrad: IEC 60898
Plug-in Miniature Circuit Breakers
Construction and Feature
=Protection against both overload and short circuit
=High short-circuit capacity
=Applicable to terminal and pin/fork type busbar connection
Technical Data
=Pole No: 1,2,3,4
=Rated voltage: AC 230/400V
=Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63
=Tripping curve: B,C,D
=Rated short-circuit capacity(lcn): 6kA
=Rated frequency: 50/60Hz
=Energy limiting calss: 3
=Rated impulse withstand voltage: 6.2kV
=Electro-mechanical endurance: 6000
=Connection terminal:
=Screw terminal
=Pillar terminal with calmp
=Connection capacity: Rigid conductor up to 25mm2
=Fastening torque: 2.0Nm
=Installation:
=Clips pan assembly base
=Panel mounting
Overall & Installation Dimensions
TOPI-1
A-33
Standrad: IEC 60898
Plug-in Miniature Circuit Breakers
Miniature
CircuitBreaker
Miniature
CircuitBreaker
Miniature
CircuitBreaker
Description
=For protection against overload and
short circuits in the electrical distribution
system.
=Use in domestic, commercial and
light industrial installations.
Overall & Installation Dimensions
Specification
Designation Rating(Amps) Pack Qty. Cat.No.
Double pole
2” width
Triple pole
3” width
Single pole
1” width
10
10
10
10
10
10
10
10
10
10
5
5
5
5
5
5
5
5
5
5
3
3
3
3
3
3
3
3
3
3
5A
10A
15A
20A
30A
40A
50A
60A
75A
100A
5A
10A
15A
20A
30A
40A
50A
60A
75A
100A
5A
10A
15A
20A
30A
40A
50A
60A
75A
100A
TOPI-2 105
TOPI-2 110
TOPI-2 115
TOPI-2 120
TOPI-2 130
TOPI-2 140
TOPI-2 150
TOPI-2 160
TOPI-2 175
TOPI-2 1100
TOPI-2 205
TOPI-2 210
TOPI-2 215
TOPI-2 220
TOPI-2 230
TOPI-2 240
TOPI-2 250
TOPI-2 260
TOPI-2 275
TOPI-2 2100
TOPI-2 305
TOPI-2 310
TOPI-2 315
TOPI-2 320
TOPI-2 330
TOPI-2 340
TOPI-2 350
TOPI-2 360
TOPI-2 375
TOPI-2 3100
Technical Data
=Conform to IEC 60898,BS 3871-Pt1
=Body material: Bakelite
=Rated Current: 5-100A
=Rated Voltage: 120,120/240,240/440V AC
=Breaking Capacity: 6kA
=Frequency: 50/60Hz
=Degree of protection:IP20
Connection
=Clamp terminal
=Mounting:
=Clips mounting base
TOPI-2
A-34
Standrad: IEC 60898
Plug-in Miniature Circuit Breakers
TOPI-3
A-35
Description
=For protection against overload and
short circuits in the electrical distribution
system.
=Use in domestic, commercial and
light industrial installations.
Overall & Installation Dimensions
Specification
Designation Rating(Amps) Pack Qty. Cat.No.
Double pole
2” width
Triple pole
3” width
Single pole
1” width
10
10
10
10
10
10
10
10
10
10
5
5
5
5
5
5
5
5
5
5
3
3
3
3
3
3
3
3
3
3
5A
10A
15A
20A
30A
40A
50A
60A
75A
100A
5A
10A
15A
20A
30A
40A
50A
60A
75A
100A
5A
10A
15A
20A
30A
40A
50A
60A
75A
100A
TOPI-3 105
TOPI-3 110
TOPI-3 115
TOPI-3 120
TOPI-3 130
TOPI-3 140
TOPI-3 150
TOPI-3 160
TOPI-3 175
TOPI-3 1100
TOPI-3 205
TOPI-3 210
TOPI-3 215
TOPI-3 220
TOPI-3 230
TOPI-3 240
TOPI-3 250
TOPI-3 260
TOPI-3 275
TOPI-3 2100
TOPI-3 305
TOPI-3 310
TOPI-3 315
TOPI-3 320
TOPI-3 330
TOPI-3 340
TOPI-3 350
TOPI-3 360
TOPI-3 375
TOPI-3 3100
Technical Data
=Conform to IEC 60898,BS 3871-Pt1
=Body material: Glassfiber polyester/Bakelite
=Rated Current: Bakelite 5-100A
=Rated Voltage: 120,120/240,240/440V AC
=Breaking Capacity: 6kA
=Frequency: 50/60Hz
=Degree of protection:IP20
Connection
=Clamp terminal
=Mounting:
=Clips mounting base
Standrad: IEC 60898
Plug-in Miniature Circuit Breakers
Miniature
CircuitBreaker
Miniature
CircuitBreaker
Miniature
CircuitBreaker
TOPI-4
A-36
Description
=For protection against overload and
short circuits in the electrical distribution
system.
=Use in domestic, commercial and
light industrial installations.
Overall & Installation Dimensions
Specification
Designation Rating(Amps) Pack Qty. Cat.No.
Double pole
2” width
Triple pole
3” width
Single pole
1” width
10
10
10
10
10
10
10
10
10
10
5
5
5
5
5
5
5
5
5
5
3
3
3
3
3
3
3
3
3
3
5A
10A
15A
20A
30A
40A
50A
60A
75A
100A
5A
10A
15A
20A
30A
40A
50A
60A
75A
100A
5A
10A
15A
20A
30A
40A
50A
60A
75A
100A
TOPI-4 105
TOPI-4 110
TOPI-4 115
TOPI-4 120
TOPI-4 130
TOPI-4 140
TOPI-4 150
TOPI-4 160
TOPI-4 175
TOPI-4 1100
TOPI-4 205
TOPI-4 210
TOPI-4 215
TOPI-4 220
TOPI-4 230
TOPI-4 240
TOPI-4 250
TOPI-4 260
TOPI-4 275
TOPI-4 2100
TOPI-4 305
TOPI-4 310
TOPI-4 315
TOPI-4 320
TOPI-4 330
TOPI-4 340
TOPI-4 350
TOPI-4 360
TOPI-4 375
TOPI-4 3100
Technical Data
=Conform to IEC 60898,BS 3871-Pt1
=Body material: Bakelite
=Rated Current: 5-100A
=Rated Voltage: 120,120/240,240/440V AC
=Breaking Capacity: 6kA
=Frequency: 50/60Hz
=Degree of protection:IP20
Connection
=Clamp terminal
=Mounting:
=Clips mounting base
Standrad: IEC 60898
Plug-in Miniature Circuit Breakers
Description
=For protection against overload and
short circuits in the electrical distribution
system.
=Use in domestic, commercial and
light industrial installations.
Overall & Installation Dimensions
Specification
Designation Rating(Amps) Pack Qty. Cat.No.
Double pole
2” width
Triple pole
3” width
Single pole
1” width
10
10
10
10
10
10
10
10
10
10
5
5
5
5
5
5
5
5
5
5
3
3
3
3
3
3
3
3
3
3
5A
10A
15A
20A
30A
40A
50A
60A
75A
100A
5A
10A
15A
20A
30A
40A
50A
60A
75A
100A
5A
10A
15A
20A
30A
40A
50A
60A
75A
100A
TOPI-5 105
TOPI-5 110
TOPI-5 115
TOPI-5 120
TOPI-5 130
TOPI-5 140
TOPI-5 150
TOPI-5 160
TOPI-5 175
TOPI-51100
TOPI-5 205
TOPI-5 210
TOPI-5 215
TOPI-5 220
TOPI-5 230
TOPI-5 240
TOPI-5 250
TOPI-5 260
TOPI-5 275
TOPI-5 2100
TOPI-5 305
TOPI-5 310
TOPI-5 315
TOPI-5 320
TOPI-5 330
TOPI-5 340
TOPI-5 350
TOPI-5 360
TOPI-5 375
TOPI-5 3100
Technical Data
=Conform to IEC 60898,BS 3871-Pt1
=Body material: Bakelite
=Rated Current: 5-100A
=Rated Voltage: 120,120/240,240/440V AC
=Breaking Capacity: 6kA
=Frequency: 50/60Hz
=Degree of protection:IP20
Connection
=Clamp terminal
=Mounting:
=Clips mounting base
TOPI-5
A-37
Standrad: IEC 60898
Plug-in Miniature Circuit Breakers
Miniature
CircuitBreaker
Miniature
CircuitBreaker
Miniature
CircuitBreaker
Description
=For protection against overload and
short circuits in the electrical distribution
system.
=Use in domestic, commercial and
light industrial installations.
Overall & Installation Dimensions
Specification
Designation Rating(Amps) Pack Qty. Cat.No.
Double pole
2” width
Triple pole
3” width
Single pole
1” width
10
10
10
10
10
10
10
10
10
10
10
5
5
5
5
5
5
5
5
5
5
5
3
3
3
3
3
3
3
3
3
3
3
6A
10A
16A
20A
25A
30A
40A
50A
60A
75A
100A
6A
10A
16A
20A
25A
30A
40A
50A
60A
75A
100A
6A
10A
16A
20A
25A
30A
40A
50A
60A
75A
100A
TOPI-M 3106
TOPI-M 3110
TOPI-M 3116
TOPI-M 3120
TOPI-M 3125
TOPI-M 3130
TOPI-M 3140
TOPI-M 3150
TOPI-M 3160
TOPI-M 3175
TOPI-M 31100
TOPI-M 3206
TOPI-M 3210
TOPI-M 3216
TOPI-M 3220
TOPI-M 3225
TOPI-M 3230
TOPI-M 3240
TOPI-M 3250
TOPI-M 3260
TOPI-M 3275
TOPI-M 32100
TOPI-M 3306
TOPI-M 3310
TOPI-M 3316
TOPI-M 3320
TOPI-M 3325
TOPI-M 3330
TOPI-M 3340
TOPI-M 3350
TOPI-M 3360
TOPI-M 3375
TOPI-M 33100
Technical Data
=Conform to IEC 60898,BS 3871-Pt1
=Body material: Bakelite/Glassfiber polyester
=Rated Current: 6-100A
=Rated Voltage: 120,120/240,240/415V AC
=AIC Rating: 10,000 RMS SYM
=Degree of protection:IP20
Connection
=Pillar type terminal
=Mounting
=Clips pan assembly base
=Plug-in mounting base
TOPI-M
A-38
Standrad: IEC 60898
Plug-in Miniature Circuit Breakers
Description
=For protection against overload and
short circuits in the electrical distribution
system.
=Use in domestic, commercial and
light industrial installations.
Overall & Installation Dimensions
Specification
Designation Rating(Amps) Pack Qty. Cat.No.
Double pole
2” width
Triple pole
3” width
Single pole
1” width
10
10
10
10
10
10
10
10
10
10
10
5
5
5
5
5
5
5
5
5
5
5
3
3
3
3
3
3
3
3
3
3
3
6A
10A
16A
20A
25A
30A
40A
50A
60A
75A
100A
6A
10A
16A
20A
25A
30A
40A
50A
60A
75A
100A
6A
10A
16A
20A
25A
30A
40A
50A
60A
75A
100A
TOPI-6 106
TOPI-6 110
TOPI-6 116
TOPI-6 120
TOPI-6 125
TOPI-6 130
TOPI-6 140
TOPI-6 150
TOPI-6 160
-
-
TOPI-6 206
TOPI-6 210
TOPI-6 216
TOPI-6 220
TOPI-6 225
TOPI-6 230
TOPI-6 240
TOPI-6 250
TOPI-6 260
-
-
TOPI-6 306
TOPI-6 310
TOPI-6 316
TOPI-6 320
TOPI-6 325
TOPI-6 330
TOPI-6 340
TOPI-6 350
TOPI-6 360
-
-
Technical Data
=Conform to IEC 60898,BS 3871-Pt1
=Body material: Glassfiber polyester/Bakelite
=Rated Current: 6-100A
=Rated Voltage: 120,120/240,240/415V AC
=Breaking Capacity: 6kA
=Frequency: 50/60Hz
=Degree of protection:IP20
Connection
=Pillar type terminal
=Mounting
=Clips pan assembly base
=Plug-in mounting base
TOPI-6 106
TOPI-6 110
TOPI-6 116
TOPI-6 120
TOPI-6 125
TOPI-6 130
TOPI-6 140
TOPI-6 150
TOPI-6 160
TOPI-6 175
TOPI-6 1100
TOPI-6 206
TOPI-6 210
TOPI-6 216
TOPI-6 220
TOPI-6 225
TOPI-6 230
TOPI-6 240
TOPI-6 250
TOPI-6 260
TOPI-6 275
TOPI-6 2100
TOPI-6 306
TOPI-6 310
TOPI-6 316
TOPI-6 320
TOPI-6 325
TOPI-6 330
TOPI-6 340
TOPI-6 350
TOPI-6 360
TOPI-6 375
TOPI-6 3100
TOPI-6
A-39
Standrad: IEC 60898
Plug-in Miniature Circuit Breakers
Miniature
CircuitBreaker
Miniature
CircuitBreaker
Miniature
CircuitBreaker
Description
=For protection against overload and
short circuits in the electrical distribution
system.
=Use in domestic, commercial and
light industrial installations.
Overall & Installation Dimensions
Specification
Designation Rating(Amps) Pack Qty. Cat.No.
Double pole
2” width
Triple pole
3” width
Single pole
1” width
10
10
10
10
10
10
10
10
10
5
5
5
5
5
5
5
5
5
3
3
3
3
3
3
3
3
3
5A
10A
16A
20A
25A
30A
40A
50A
60A
5A
10A
16A
20A
25A
30A
40A
50A
60A
5A
10A
16A
20A
25A
30A
40A
50A
60A
TOPI-7 105
TOPI-7 110
TOPI-7 116
TOPI-7 120
TOPI-7 125
TOPI-7 130
TOPI-7 140
TOPI-7 150
TOPI-7 160
TOPI-7 205
TOPI-7 210
TOPI-7 216
TOPI-7 220
TOPI-7 225
TOPI-7 230
TOPI-7 240
TOPI-7 250
TOPI-7 260
TOPI-7 305
TOPI-7 310
TOPI-7 316
TOPI-7 320
TOPI-7 325
TOPI-7 330
TOPI-7 340
TOPI-7 350
TOPI-7 360
Technical Data
=Conform to IEC 60898 BS 3871-Pt1
=Body material: Glassfiber polyester/Bakelite
=Rated Current: 5-60A
=Rated Voltage: 120,120/240,240/415V AC
=Breaking Capacity: 3KA
=Frequency: 50/60Hz
=Degree of protection:IP20
Connection
=Clamp terminal
=Mounting
=Clips mounting base
TOPI-7
A-40
Standrad: IEC 60898
Plug-in Miniature Circuit Breakers
Description
=For protection against overload and
short circuits in the electrical distribution
system.
=Use in domestic, commercial and
light industrial installations.
Overall & Installation Dimensions
Specification
Designation
Double pole
2” width
Triple pole
3” width
Single pole
1” width
Technical Data
=Conform to IEC 60898,UL489
=Body material: Bakelite
=Rated Current: 15-100A
=Rated Voltage: 120,120/240,240/415VAC
=AIC Rating: 10,000 RMS SYM
=Degree of protection:IP20
Connection
=Pillar type terminal
=Mounting
=Clips pan assembly base
=Plug-in mounting base
Rating(Amps) Pack Qty. Cat.No.
10
10
10
10
10
10
10
10
5
5
5
5
5
5
5
5
3
3
3
3
3
3
3
3
15A
20A
30A
40A
50A
60A
75A
100A
15A
20A
30A
40A
50A
60A
75A
100A
15A
20A
30A
40A
50A
60A
75A
100A
TOPI-8 1115
TOPI-8 1120
TOPI-8 1130
TOPI-8 1140
TOPI-8 1150
TOPI-8 1160
TOPI-8 1175
TOPI-8 11100
TOPI-8 1215
TOPI-8 1220
TOPI-8 1230
TOPI-8 1240
TOPI-8 1250
TOPI-8 1260
TOPI-8 1275
TOPI-8 12100
TOPI-8 1315
TOPI-8 1320
TOPI-8 1330
TOPI-8 1340
TOPI-8 1350
TOPI-8 1360
TOPI-8 1375
TOPI-8 13100
TOPI-8
A-41
Standrad: IEC 60898
Plug-in Miniature Circuit Breakers
Miniature
CircuitBreaker
Miniature
CircuitBreaker
Miniature
CircuitBreaker
Description
=For protection against overload and
short circuits in the electrical distribution
system.
=Use in domestic, commercial and
light industrial installations.
Overall & Installation Dimensions
Specification
Designation Rating(Amps) Pack Qty. Cat.No.
Double pole
1” width
Single pole
1/2” width
10
10
10
10
10
5
5
5
5
5
15A
20A
30A
40A
50A
15A
20A
30A
40A
50A
TOPI-9 1115
TOPI-9 1120
TOPI-9 1130
TOPI-9 1140
TOPI-9 1150
TOPI-9 1215
TOPI-9 1220
TOPI-9 1230
TOPI-9 1240
TOPI-9 1250
Technical Data
=Conform to IEC 60898,UL489
=Body material: Bakelite
=Rated Current: 15-50A
=Rated Voltage: 120,120/240,240/415VAC
=AIC Rating: 10,000 RMS SYM
=Degree of protection: IP20
Connection
=Pillar type terminal
=Mounting
=Clips pan assembly base
=Plug-in mounting base
TOPI-9
A-42
Standrad: IEC 60898
Plug-in Miniature Circuit Breakers
Description
=For protection against overload and
short circuits in the electrical distribution
system.
=Use in domestic, commercial and
light industrial installations.
Overall & Installation Dimensions
Specification
Designation Rating(Amps) Pack Qty. Cat.No.
Double pole
2” width
Triple pole
3” width
Single pole
1” width
10
10
10
10
10
10
10
10
5
5
5
5
5
5
5
5
3
3
3
3
3
3
3
3
15A
20A
30A
40A
50A
60A
75A
100A
15A
20A
30A
40A
50A
60A
75A
100A
15A
20A
30A
40A
50A
60A
75A
100A
TOPI-10 2115
TOPI-10 2120
TOPI-10 2130
TOPI-10 2140
TOPI-10 2150
TOPI-10 2160
TOPI-10 2175
TOPI-10 21100
TOPI-10 2215
TOPI-10 2220
TOPI-10 2230
TOPI-10 2240
TOPI-10 2250
TOPI-10 2260
TOPI-10 2275
TOPI-10 22100
TOPI-10 2315
TOPI-10 2320
TOPI-10 2330
TOPI-10 2340
TOPI-10 2350
TOPI-10 2360
TOPI-10 2375
TOPI-10 23100
Technical Data
=Conform to IEC 60898,UL489
=Body material: Bakelite
=Rated Current: 15-100A
=Rated Voltage: 120,120/240,240/415V AC
=AIC Rating: 10,000 RMS SYM
=Degree of protection:IP20
Connection
=Clamp terminal
=Mounting
=Clips pan assembly base
=Plug-in mounting base
TOPI-10
A-43
Standrad: IEC 60898
Plug-in Miniature Circuit Breakers
Miniature
CircuitBreaker
Miniature
CircuitBreaker
Miniature
CircuitBreaker
Construction and Feature
=Protection against overload
=High short-circuit capacity
Technical Data
=Pole No: 2
=Rated voltage: AC 230/400V
=Rated current(A): 10,16,20,25,32
=Tripping curve: B,C,D
=Ultimate short-circuit capacity(lcu): 4.5KA
=Rated frequency: 50/60Hz
=Energy limiting class: 3
=Rated impulse withstand voltage: 6.2KV
=Electro-mechanical endurance: 4000
=Connection terminal: Pillar terminal with clamp
=Connection capacity: Rigid conductor up to 25mm2
=Fastening torque: 2.0Nm
=Installation:
=Panel mounting
TOMT-50
Miniature Circuit Breaker
A-44
Overall & Installation Dimensions

Contenu connexe

Tendances

Tendances (20)

Ac voltage
Ac voltageAc voltage
Ac voltage
 
circuit breaker
circuit breakercircuit breaker
circuit breaker
 
Generator grounding
Generator groundingGenerator grounding
Generator grounding
 
132 KV Grid Station Intern ship training report
132 KV Grid Station Intern ship training report132 KV Grid Station Intern ship training report
132 KV Grid Station Intern ship training report
 
Lightning protection to structures and power systems
Lightning protection to structures and power systemsLightning protection to structures and power systems
Lightning protection to structures and power systems
 
Testing of circuit breakers
Testing of circuit breakersTesting of circuit breakers
Testing of circuit breakers
 
Automatic Generation Control
Automatic Generation ControlAutomatic Generation Control
Automatic Generation Control
 
Relay coordination
Relay coordinationRelay coordination
Relay coordination
 
Switchgear and protection 2
Switchgear and protection 2Switchgear and protection 2
Switchgear and protection 2
 
Protection against over voltage
Protection against over voltageProtection against over voltage
Protection against over voltage
 
Power system protection devices
Power system protection devicesPower system protection devices
Power system protection devices
 
Electrical safety in power stations
Electrical safety in power stationsElectrical safety in power stations
Electrical safety in power stations
 
Substation Maintenance
Substation MaintenanceSubstation Maintenance
Substation Maintenance
 
Smart energy meter (Updated)
Smart energy meter (Updated)Smart energy meter (Updated)
Smart energy meter (Updated)
 
Power system stability
Power system stability Power system stability
Power system stability
 
relay-distance relay basics
relay-distance relay basicsrelay-distance relay basics
relay-distance relay basics
 
Design planning & layout of high voltage laboratory
Design planning & layout of high voltage laboratoryDesign planning & layout of high voltage laboratory
Design planning & layout of high voltage laboratory
 
Electrical substation (one and half breaker scheme)
Electrical substation (one and half breaker scheme)Electrical substation (one and half breaker scheme)
Electrical substation (one and half breaker scheme)
 
Switchgear Equipment in a Substation
Switchgear Equipment in a SubstationSwitchgear Equipment in a Substation
Switchgear Equipment in a Substation
 
Vacuum Circuit Breaker (VCB) Working and Applications | Uses Of VCB
Vacuum Circuit Breaker (VCB) Working and Applications | Uses Of VCB Vacuum Circuit Breaker (VCB) Working and Applications | Uses Of VCB
Vacuum Circuit Breaker (VCB) Working and Applications | Uses Of VCB
 

En vedette

En vedette (16)

Contactor thermal relay catalogue
Contactor thermal relay catalogueContactor thermal relay catalogue
Contactor thermal relay catalogue
 
Rcbo catalogue
Rcbo catalogueRcbo catalogue
Rcbo catalogue
 
Tongou electrical catalogue
Tongou electrical catalogue Tongou electrical catalogue
Tongou electrical catalogue
 
Rccb catalogue
Rccb catalogueRccb catalogue
Rccb catalogue
 
Mccb catalogue
Mccb catalogueMccb catalogue
Mccb catalogue
 
Distribution box catalogue
Distribution box catalogueDistribution box catalogue
Distribution box catalogue
 
Disconnector switch catalogue
Disconnector switch catalogueDisconnector switch catalogue
Disconnector switch catalogue
 
Iwiss Fiber Optic Tools Catalogue 2013
Iwiss Fiber Optic Tools Catalogue 2013Iwiss Fiber Optic Tools Catalogue 2013
Iwiss Fiber Optic Tools Catalogue 2013
 
Iwiss Power Fitting Catalogue 2014
Iwiss Power Fitting Catalogue 2014Iwiss Power Fitting Catalogue 2014
Iwiss Power Fitting Catalogue 2014
 
Iwiss Wire Processing Machine Catalogue 2013
Iwiss Wire Processing Machine Catalogue 2013Iwiss Wire Processing Machine Catalogue 2013
Iwiss Wire Processing Machine Catalogue 2013
 
Wiring Accessories - Wire Terminals,Cable Gland,Cable Connectors,Cable Ties
Wiring Accessories - Wire Terminals,Cable Gland,Cable Connectors,Cable TiesWiring Accessories - Wire Terminals,Cable Gland,Cable Connectors,Cable Ties
Wiring Accessories - Wire Terminals,Cable Gland,Cable Connectors,Cable Ties
 
Iwiss Hydraulic Tools Catalogue Main 2013-2014
Iwiss Hydraulic Tools Catalogue Main 2013-2014Iwiss Hydraulic Tools Catalogue Main 2013-2014
Iwiss Hydraulic Tools Catalogue Main 2013-2014
 
Iwiss Tools Catalogue - Solar Tools,Heavy Duty Connector Tools, Network Tools...
Iwiss Tools Catalogue - Solar Tools,Heavy Duty Connector Tools, Network Tools...Iwiss Tools Catalogue - Solar Tools,Heavy Duty Connector Tools, Network Tools...
Iwiss Tools Catalogue - Solar Tools,Heavy Duty Connector Tools, Network Tools...
 
Iwiss pressing-tools-for-pipes-201301
Iwiss pressing-tools-for-pipes-201301Iwiss pressing-tools-for-pipes-201301
Iwiss pressing-tools-for-pipes-201301
 
Industrial lighting Catalogue Iwiss Electric Co.,Ltd
Industrial lighting Catalogue Iwiss Electric Co.,LtdIndustrial lighting Catalogue Iwiss Electric Co.,Ltd
Industrial lighting Catalogue Iwiss Electric Co.,Ltd
 
Full Automatic Terminal Crimping Machine Iwiss Tools
Full Automatic Terminal Crimping Machine Iwiss ToolsFull Automatic Terminal Crimping Machine Iwiss Tools
Full Automatic Terminal Crimping Machine Iwiss Tools
 

Similaire à Mcb catalogue

1 residual current circuit breaker (rccb) ( elcb)
1 residual current circuit breaker (rccb) ( elcb)1 residual current circuit breaker (rccb) ( elcb)
1 residual current circuit breaker (rccb) ( elcb)
nikeshdubey
 
Earthing and disconnecting panel report.pdf
Earthing and disconnecting panel report.pdfEarthing and disconnecting panel report.pdf
Earthing and disconnecting panel report.pdf
MohitKumar989420
 

Similaire à Mcb catalogue (20)

Catalog cs fdp
Catalog cs fdpCatalog cs fdp
Catalog cs fdp
 
Catalog cs mcb rccb
Catalog cs mcb rccbCatalog cs mcb rccb
Catalog cs mcb rccb
 
Catalog cs mcb rccb dienhathe.vn
Catalog cs mcb rccb dienhathe.vnCatalog cs mcb rccb dienhathe.vn
Catalog cs mcb rccb dienhathe.vn
 
Catalog cs mcb rccb
Catalog cs mcb rccbCatalog cs mcb rccb
Catalog cs mcb rccb
 
Catalog cs fdp
Catalog cs fdpCatalog cs fdp
Catalog cs fdp
 
Catalog cs fdp dienhathe.vn
Catalog cs fdp dienhathe.vnCatalog cs fdp dienhathe.vn
Catalog cs fdp dienhathe.vn
 
Crouzet Aerospace - Electrical Protection & Distribution
Crouzet Aerospace - Electrical Protection & DistributionCrouzet Aerospace - Electrical Protection & Distribution
Crouzet Aerospace - Electrical Protection & Distribution
 
1 residual current circuit breaker (rccb) ( elcb)
1 residual current circuit breaker (rccb) ( elcb)1 residual current circuit breaker (rccb) ( elcb)
1 residual current circuit breaker (rccb) ( elcb)
 
Mcbelcb
McbelcbMcbelcb
Mcbelcb
 
Earthing and disconnecting panel report.pdf
Earthing and disconnecting panel report.pdfEarthing and disconnecting panel report.pdf
Earthing and disconnecting panel report.pdf
 
Electrical System.ppsx
Electrical System.ppsxElectrical System.ppsx
Electrical System.ppsx
 
Electrical Installations, MCB, MCCB, ELCB
Electrical Installations, MCB, MCCB, ELCBElectrical Installations, MCB, MCCB, ELCB
Electrical Installations, MCB, MCCB, ELCB
 
VOCATIONAL TRAINING FROM SECL , SOHAGPUR , KHAIRHA MINE , PPT (POWER POINT PR...
VOCATIONAL TRAINING FROM SECL , SOHAGPUR , KHAIRHA MINE , PPT (POWER POINT PR...VOCATIONAL TRAINING FROM SECL , SOHAGPUR , KHAIRHA MINE , PPT (POWER POINT PR...
VOCATIONAL TRAINING FROM SECL , SOHAGPUR , KHAIRHA MINE , PPT (POWER POINT PR...
 
Catalog Motor CB Fuji Electric
Catalog Motor CB Fuji ElectricCatalog Motor CB Fuji Electric
Catalog Motor CB Fuji Electric
 
Components of LT Switchgear.pptx
Components of LT Switchgear.pptxComponents of LT Switchgear.pptx
Components of LT Switchgear.pptx
 
Industrial Miniature Circuit Breaker Suppliers in Vadodara | Shreelight Power
Industrial Miniature Circuit Breaker Suppliers in Vadodara | Shreelight PowerIndustrial Miniature Circuit Breaker Suppliers in Vadodara | Shreelight Power
Industrial Miniature Circuit Breaker Suppliers in Vadodara | Shreelight Power
 
02- Manual Motor Starter - Fuji Electric
02- Manual Motor Starter - Fuji Electric02- Manual Motor Starter - Fuji Electric
02- Manual Motor Starter - Fuji Electric
 
L.v tech presentation 2
L.v tech presentation 2L.v tech presentation 2
L.v tech presentation 2
 
Surge Protection - Main Incoming Supply Sub Distribution Boards Socket Outlet...
Surge Protection - Main Incoming Supply Sub Distribution Boards Socket Outlet...Surge Protection - Main Incoming Supply Sub Distribution Boards Socket Outlet...
Surge Protection - Main Incoming Supply Sub Distribution Boards Socket Outlet...
 
MV Switchgear from IEEE
MV Switchgear from IEEEMV Switchgear from IEEE
MV Switchgear from IEEE
 

Dernier

Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Victor Rentea
 
Architecting Cloud Native Applications
Architecting Cloud Native ApplicationsArchitecting Cloud Native Applications
Architecting Cloud Native Applications
WSO2
 
Why Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businessWhy Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire business
panagenda
 

Dernier (20)

Elevate Developer Efficiency & build GenAI Application with Amazon Q​
Elevate Developer Efficiency & build GenAI Application with Amazon Q​Elevate Developer Efficiency & build GenAI Application with Amazon Q​
Elevate Developer Efficiency & build GenAI Application with Amazon Q​
 
Platformless Horizons for Digital Adaptability
Platformless Horizons for Digital AdaptabilityPlatformless Horizons for Digital Adaptability
Platformless Horizons for Digital Adaptability
 
Introduction to Multilingual Retrieval Augmented Generation (RAG)
Introduction to Multilingual Retrieval Augmented Generation (RAG)Introduction to Multilingual Retrieval Augmented Generation (RAG)
Introduction to Multilingual Retrieval Augmented Generation (RAG)
 
Six Myths about Ontologies: The Basics of Formal Ontology
Six Myths about Ontologies: The Basics of Formal OntologySix Myths about Ontologies: The Basics of Formal Ontology
Six Myths about Ontologies: The Basics of Formal Ontology
 
DEV meet-up UiPath Document Understanding May 7 2024 Amsterdam
DEV meet-up UiPath Document Understanding May 7 2024 AmsterdamDEV meet-up UiPath Document Understanding May 7 2024 Amsterdam
DEV meet-up UiPath Document Understanding May 7 2024 Amsterdam
 
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
 
Architecting Cloud Native Applications
Architecting Cloud Native ApplicationsArchitecting Cloud Native Applications
Architecting Cloud Native Applications
 
Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...
 
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
 
Apidays New York 2024 - APIs in 2030: The Risk of Technological Sleepwalk by ...
Apidays New York 2024 - APIs in 2030: The Risk of Technological Sleepwalk by ...Apidays New York 2024 - APIs in 2030: The Risk of Technological Sleepwalk by ...
Apidays New York 2024 - APIs in 2030: The Risk of Technological Sleepwalk by ...
 
AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of Terraform
 
Apidays New York 2024 - Passkeys: Developing APIs to enable passwordless auth...
Apidays New York 2024 - Passkeys: Developing APIs to enable passwordless auth...Apidays New York 2024 - Passkeys: Developing APIs to enable passwordless auth...
Apidays New York 2024 - Passkeys: Developing APIs to enable passwordless auth...
 
CNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In PakistanCNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In Pakistan
 
presentation ICT roal in 21st century education
presentation ICT roal in 21st century educationpresentation ICT roal in 21st century education
presentation ICT roal in 21st century education
 
MINDCTI Revenue Release Quarter One 2024
MINDCTI Revenue Release Quarter One 2024MINDCTI Revenue Release Quarter One 2024
MINDCTI Revenue Release Quarter One 2024
 
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
 
"I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ..."I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ...
 
MS Copilot expands with MS Graph connectors
MS Copilot expands with MS Graph connectorsMS Copilot expands with MS Graph connectors
MS Copilot expands with MS Graph connectors
 
Why Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businessWhy Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire business
 
DBX First Quarter 2024 Investor Presentation
DBX First Quarter 2024 Investor PresentationDBX First Quarter 2024 Investor Presentation
DBX First Quarter 2024 Investor Presentation
 

Mcb catalogue

  • 1.
  • 2. TONGOU Electrical is one of the most specialized manufacturers and exports for modular electric terminal devices for household,commerical, industrial and similar installations in china. The wide range products under manufacturing covers Miniature Citcuit Breaker(MCB), Residual Current Circuit Breaker(RCCB), Residual Current Circuit Breakers with Overcurrent Protection(RCBO), Switch- disconnector, Distribution Box, Moulded case circuit breaker(MCCB), air circuit breaker(ACB), AC Contactor, Magnetic Starter, Motor Protection Circuit Breaker and Thermal Relay etc. The company takes the reputation as one of the largest manufacturer of electromagnetic type RCCB and RCBO. OEM or ODM projects are fully accepted, and currently the company is co- operating with numbers of renowned international corporations for such project. In order to create distinguished achievement,we insist on “3S” “SAFE with (Warranty, qualification, fully tested), SAVE with ( Time, Cost, Energy), Smile with(Service,Future, Attitude)” TONGOU Electrical possesses full line of high-tech production equip- ment and great strength of technology support besides advanced des- ignation forces powered by the first class engineering teams with su- per industrial computer systems. Thus, our products are novel in design, excellent in workmanship and top reliable in quality. Experience in manufacturing under customers design, trade, biding project, OEM and competitive cooperation related to the new prod- ucts & technology. Won approvals of CE, SEMKO, CB, CCC and ISO9001 Quality System Certificate etc. Products being popular around the world, such as Europe, America, Southeast Asia, Middle East, Africa, etc. www.elcb.net www.chinatongou.com About TONGOU
  • 3. TONGOU poroducts are certified by the following international certificates: International Germany Germany Sweden EU Netheland USA Argentina China
  • 5. Standrad: IEC 60898 Miniature Circuit Breaker Miniature Circuit Breaker A TOMP1-32 Miniature Circuit Breaker ........................... TOMPG-32 Miniature Circuit Breaker .......................... TOMP10-32 Miniature Circuit Breaker ......................... TOMP11-32 Miniature Circuit Breaker .......................... TOM10-100 Miniature Circuit Breaker .......................... TOM65-100Miniature Circuit Breaker ........................... TOMG1-100 Miniature Circuit Breaker ......................... TOML1-100 Miniature Circuit Breaker .......................... TOMS1-100 Miniature Circuit Breaker ......................... Miniature Circuit Breaker Electrical Accessories .......... Modular Indicator .......................................................... TOPI-1 Plug-in Miniature Circuit Breakers ........................ TOPI-2 Plug-in Miniature Circuit Breakers ........................ TOPI-3 Plug-in Miniature Circuit Breakers ........................ TOPI-4 Plug-in Miniature Circuit Breakers ........................ TOPI-5 Plug-in Miniature Circuit Breakers ........................ TOPI-M Plug-in Miniature Circuit Breakers ....................... TOPI-6 Plug-in Miniature Circuit Breakers ........................ TOPI-7 Plug-in Miniature Circuit Breakers ...................... TOPI-8 Plug-in Miniature Circuit Breakers .................... TOPI-9 Plug-in Miniature Circuit Breakers ....................... TOPI-10 Plug-in Miniature Circuit Breakers .................. TOMT-50 Miniature Circuit Breaker .............................. A-23 A-24 A-25 A-25 A-26 A-27 A-28 A-29 A-30 A-31 A-32 A-33 A-34 A-35 A-36 A-37 A-38 A-39 A-40 A-41 A-42 A-43 A-44 TOMN1-63 Miniature Circuit Breaker ....................... TOMC1-63 Miniature Circuit Breaker ....................... TOMC2-63 Miniature Circuit Breaker ....................... TOMC3-63 Miniature Circuit Breaker ....................... TOM71-63 Miniature Circuit Breaker ....................... TOM72-63 Miniature Circuit Breaker ....................... TOM7B-63Miniature Circuit Breaker ....................... TOMHW-63(3KA) Miniature Circuit Breaker ............. TOMHU-63(6KA) Miniature Circuit Breaker ............. TOMHC-63 Miniature Circuit Breaker ..................... TOMHT-63 Miniature Circuit Breaker ...................... TOMHB-63 Miniature Circuit Breaker ...................... TOM10-63 Miniature Circuit Breaker ....................... TOM11-63 Miniature Circuit Breaker ....................... TOM12-63 Miniature Circuit Breaker ....................... TOM65-63 Miniature Circuit Breaker ....................... TOMG1-63 Miniature Circuit Breaker ..................... TOML1-63 Miniature Circuit Breaker ....................... TOML2-63 Miniature Circuit Breaker ....................... TOM30-63 Miniature Circuit Breaker ....................... TOMS1-63 Miniature Circuit Breaker ..................... TOMS2-63 Miniature Circuit Breaker ..................... TOMS3-63 Miniature Circuit Breaker ..................... A-01 A-02 A-03 A-04 A-05 A-06 A-07 A-08 A-08 A-09 A-10 A-11 A-12 A-13 A-14 A-15 A-16 A-17 A-18 A-19 A-20 A-21 A-22
  • 6. Standrad: IEC 60898 Miniature Circuit Breaker MCB is applicable to electric circuits with rated voltage 230/400V AC, frequency 50/60Hz and rated current up to 125Amp. The product provides protection against voerload and short circuit to electric circuits and equipments in household and commercial installation. MCB is also used as non-frequent changeover of electric circuits. Special tips: 1. MCB is for non-professional operation by those untrained, and no maintenance is required 2. Satisfying conditions and applications as mentioned above,MCB with “ON-OFF” indicating device is considered suitable for isolation function. 3. Particular devices such as surge protective devices,surge arrester etc are recommended to install at upstream line to MCB as precaution against potential surge voltage and current occurring at its power input side. 4. Appropriate tripping curve being chosen and properly installed, MCB trips and switches off its protected circuit in case of fault, and thus provides protection against electric shock. 5. B,C,D tripping curve(see graphics 1): B cure: =Instantaneous tripping current:5In =Instantaneous non-tripping current:3In =Application:provides protection to circuits with low inductive load C curve: =Instantaneous tripping current:10In =Instantaneous non-tripping current:5In =Application:provides protection to circuits with inductive load or to highly inductive illumination system D curve: =Instantaneous tripping current: 20In =Instantaneous non-tripping current:10In =Application:provides protection to circuits with high inductive load or electric distribution system with high surge current 6. Ambient temperature and current rating curve GENERAL Miniature Circuit Breaker Http://www.elcb.net
  • 7. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =The state-of-art design =Elegant appearance;cover and handle in arc shape make comfortable operation. =Contact position indicating window =Transparent cover designed to carry label. =Handle central-staying function for circuit fault indicating =In case of overload, to protect circuit,MCB handle trips and stays at central position, which enables a quick solution to the faulty line. The handle cannot stay in such position when operated manually. =High short-circuit capacity =High short-circuit capacity 6KA for whole range and 10kA capacity for current rating up to 40A thanks to the powerful electric arc extinguishing system. =Long electrical endurance up to 6000 cycles thanks to quick making mechanism. =Handle padlock device =MCB handle can be locked either at “ON” position or at “OFF” position to prevent unwanted operation of the product. =Screw terminal lock device =The lock device prevents unwanted or casual dismounting of connected terminals. Overall & Installation Dimensions Technical Data =Pole No: 1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve: B,C,D =Rated short-circuit capacity(lcn): 6kA =Rated service short-circuit breaking capacity(lcs): 7.5kA =Rated frequency: 50/60Hz =Energy limiting class: 3 =Rated impulse withstand voltage: 6.2kV =Electro-mechanical endurance: 8000 =Contact positon indication =Connection terminal: =Screw terminal =Pillar terminal with clamp =Connection capacity: Rigid conductor up to 25mm2 =Fastening torque: 2.0Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting TOMN1-63 A-01
  • 8. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Contact position indication =Applicable to terminal and pin/fork type busbar connection =Easy mounting onto 35mm DIN rail Overall & Installation Dimensions Technical Data =Pole No:1,2,3,4 =Rated voltage:AC 230/400V =Rated current(A):1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve:B,C,D =Rated short-circuit capacity(lcn):6kA =Rated frequency:50/60Hz =Energy limiting calss:3 =Rated impulse withstand voltage:6.2kV =Electro-mechanical endurance: 6000 =Contact position indication =Connection terminal: =Screw terminal =Pillar terminal with calmp =Connection capacity:Rigid conductor up to 25mm2 =Fastening torque:2.0Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting TOMC1-63 Miniature CircuitBreaker A-02
  • 9. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Contact position indication =Applicable to terminal and pin/fork type busbar connection =Easy mounting onto 35mm DIN rail Technical Data =Pole No:1,2,3,4 =Rated voltage:AC 230/400V =Rated current(A):1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve:B,C,D =Rated short-circuit capacity(lcn):6kA =Rated frequency:50/60Hz =Energy limiting calss:3 =Rated impulse withstand voltage:6.2kV =Electro-mechanical endurance: 6000 =Contact position indication =Connection terminal: =Screw terminal =Pillar terminal with calmp =Connection capacity:Rigid conductor up to 25mm2 =Fastening torque:2.0Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting Overall & Installation Dimensions TOMC2-63 A-03
  • 10. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Contact position indication =Applicable to terminal and pin/fork type busbar connection =Easy mounting onto 35mm DIN rail Overall & Installation Dimensions Technical Data =Pole No:1,2,3,4 =Rated voltage:AC 230/400V =Rated current(A):1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve:B,C,D =Rated short-circuit capacity(lcn):6kA =Rated frequency:50/60Hz =Energy limiting calss:3 =Rated impulse withstand voltage:6.2kV =Electro-mechanical endurance: 6000 =Contact position indication =Connection terminal: =Screw terminal =Pillar terminal with calmp =Connection capacity:Rigid conductor up to 25mm2 =Fastening torque:2.0Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting TOMC3-63 Miniature CircuitBreaker A-04
  • 11. Standrad: IEC 60898 Miniature Circuit Breaker Overall & Installation Dimensions 50 66 78 17.5 35 52.5 70 81 45 35.5 Technical Data =Pole No:1,2,3,4 =Rated voltage:AC 230/400V =Rated current(A):1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve:B,C,D =Rated short-circuit capacity(lcn):6kA =Rated frequency:50/60Hz =Energy limiting calss:3 =Rated impulse withstand voltage:6.2kV =Electro-mechanical endurance: 6000 =Contact position indication =Connection terminal: =Screw terminal =Pillar terminal with calmp =Connection capacity:Rigid conductor up to 25mm2 =Fastening torque:2.0Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Contact position indication =Applicable to terminal and pin/fork type busbar connection =Easy mounting onto 35mm DIN rail TOM71-63 A-05
  • 12. Standrad: IEC 60898 Miniature Circuit Breaker Overall & Installation Dimensions 17.5 50 66 76 35 52.5 70 80 45 36 Technical Data =Pole No: 1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve: B,C,D =Rated short-circuit capacity(lcn): 6kA =Rated frequency: 50/60Hz =Energy limiting calss: 3 =Rated impulse withstand voltage: 6.2kV =Electro-mechanical endurance: 6000 =Contact position indication =Connection terminal: =Screw terminal =Pillar terminal with calmp =Connection capacity: Rigid conductor up to 25mm2 =Fastening torque: 2.0Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Contact position indication =Applicable to terminal and pin/fork type busbar connection =Easy mounting onto 35mm DIN rail TOM72-63 Miniature CircuitBreaker A-06
  • 13. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Contact position indication =Applicable to terminal and pin/fork type busbar connection =Easy mounting onto 35mm DIN rail Overall & Installation Dimensions 18 36 54 50 80 45 35 66 72 Technical Data =Pole No: 1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve: B,C,D =Rated short-circuit capacity(lcn): 6kA =Rated frequency: 50/60Hz =Energy limiting calss: 3 =Rated impulse withstand voltage: 6.2kV =Electro-mechanical endurance: 6000 =Contact position indication =Connection terminal: =Screw terminal =Pillar terminal with calmp =Connection capacity:Rigid conductor up to 25mm2 =Fastening torque: 2.0Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting TOM7B-63 A-07
  • 14. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Applicable to terminal and pin/fork type busbar connection =Easy mounting onto 35mm DIN rail Overall & Installation Dimensions =Pole No: 1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve: B,C,D =Rated short-circuit capacity(lcn): 3kA,6kA =Rated frequency: 50/60Hz =Energy limiting calss: 3 =Rated impulse withstand voltage: 6.2kV =Electro-mechanical endurance: 6000 =Connection terminal: =Screw terminal =Pillar terminal with calmp =Connection capacity:Rigid conductor up to 25mm2 =Fastening torque:2.0Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting Technical Data TOMHW-63(3KA) TOMHU-63(6KA) Miniature CircuitBreaker A-08
  • 15. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Contact position indication =Applicable to terminal and pin/fork type busbar connection =Easy mounting onto 35mm DIN rail Overall & Installation Dimensions 18 36 54 72 Technical Data =Pole No: 1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve: B,C,D =Rated short-circuit capacity(lcn): 6kA =Rated frequency: 50/60Hz =Energy limiting calss: 3 =Rated impulse withstand voltage: 6.2kV =Electro-mechanical endurance: 6000 =Contact position indication =Connection terminal: =Screw terminal =Pillar terminal with calmp =Connection capacity:Rigid conductor up to 25mm2 =Fastening torque: 2.0Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting TOMHC-63 A-09
  • 16. Standrad: IEC 60898 Miniature Circuit Breaker Overall & Installation Dimensions Technical Data =Pole No: 1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve: B,C,D =Rated short-circuit capacity(lcn): 6kA =Rated frequency: 50/60Hz =Energy limiting calss: 3 =Rated impulse withstand voltage: 6.2kV =Electro-mechanical endurance: 6000 =Connection terminal: =Screw terminal =Pillar terminal with calmp =Connection capacity: Rigid conductor up to 25mm2 =Fastening torque: 2.0Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Applicable to terminal and pin/fork type busbar connection =Easy mounting onto 35mm DIN rail TOMHT-63 Miniature CircuitBreaker A-10
  • 17. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Transparent cover designed to carry label =Applicable to terminal and pin/fork type busbar connection =Easy mounting onto 35mm DIN rail Overall & Installation Dimensions Technical Data =Pole No: 1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve: B,C,D =Rated short-circuit capacity(lcn): 6kA =Rated frequency: 50/60Hz =Energy limiting calss: 3 =Rated impulse withstand voltage: 6.2kV =Electro-mechanical endurance: 6000 =Connection terminal: =Screw terminal =Pillar terminal with calmp =Connection capacity: Rigid conductor up to 25mm2 =Fastening torque: 2.0Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting TOMHB-63 A-11
  • 18. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Easy mounting onto 35mm DIN rail Overall & Installation Dimensions Technical Data =Pole No: 1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve: B,C,D =Ultimate short-circuit capacity(lcu): 4.5KA =Rated frequency: 50/60Hz =Energy limiting class: 3 =Rated impulse withstand voltage: 6.2KV =Electro-mechanical endurance: 4000 =Connection terminal: Pillar terminal with clamp =Connection capacity: Rigid conductor up to 25mm2 =Fastening torque: 2.0Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting TOM10-63 Miniature CircuitBreaker A-12
  • 19. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Easy mounting onto 35mm DIN rail TOM11-63 A-13 Technical Data =Pole No:1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve: B,C,D =Rated short-circuit capacity(lcn): 6kA =Rated frequency: 50/60Hz =Energy limiting calss: 3 =Rated impulse withstand voltage: 6.2kV =Electro-mechanical endurance: 6000 =Connection terminal: =Screw terminal =Pillar terminal with calmp =Connection capacity:Rigid conductor up to 25mm2 =Fastening torque:2.0Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting Overall & Installation Dimensions
  • 20. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Easy mounting onto 35mm DIN rail TOM12-63 Miniature CircuitBreaker A-14 Overall & Installation Dimensions Technical Data =Pole No: 1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve: B,C,D =Ultimate short-circuit capacity(lcu): 6KA =Rated frequency: 50/60Hz =Energy limiting class: 3 =Rated impulse withstand voltage: 6.2KV =Electro-mechanical endurance: 4000 =Connection terminal: Pillar terminal with clamp =Connection capacity: Rigid conductor up to 25mm2 =Fastening torque: 2.0Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting
  • 21. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Easy mounting onto 35mm DIN rail TOM65-63 A-15 Technical Data =Pole No:1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve: B,C,D =Rated short-circuit capacity(lcn): 6kA =Rated frequency: 50/60Hz =Energy limiting calss: 3 =Rated impulse withstand voltage: 6.2kV =Electro-mechanical endurance: 6000 =Connection terminal: =Screw terminal =Pillar terminal with calmp =Connection capacity: Rigid conductor up to 25mm2 =Fastening torque:2.0Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting 36 54 72 Overall & Installation Dimensions
  • 22. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Easy mounting onto 35mm DIN rail Overall & Installation Dimensions TOMG1-63 Miniature CircuitBreaker A-16 Technical Data =Pole No:1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve: B,C,D =Rated short-circuit capacity(lcn): 6kA =Rated frequency: 50/60Hz =Energy limiting calss: 3 =Rated impulse withstand voltage: 6.2kV =Electro-mechanical endurance: 6000 =Connection terminal: =Screw terminal =Pillar terminal with calmp =Connection capacity: Rigid conductor up to 25mm2 =Fastening torque: 2.0Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting
  • 23. Standrad: IEC 60898 Miniature Circuit Breaker TOML1-63 Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Applicable to terminal and pin/fork type busbar connection =Easy mounting onto 35mm DIN rail A-17 36 54 72 Overall & Installation Dimensions Technical Data =Pole No: 1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve: B,C,D =Rated short-circuit capacity(lcn): 6kA =Rated frequency: 50/60Hz =Energy limiting calss: 3 =Rated impulse withstand voltage: 6.2kV =Electro-mechanical endurance: 6000 =Connection terminal: =Screw terminal =Pillar terminal with calmp =Connection capacity: Rigid conductor up to 25mm2 =Fastening torque: 2.0Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting
  • 24. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Applicable to terminal and pin/fork type busbar connection =Easy mounting onto 35mm DIN rail Technical Data =Pole No: 1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve: B,C,D =Rated short-circuit capacity(lcn): 6kA =Rated frequency: 50/60Hz =Energy limiting calss: 3 =Rated impulse withstand voltage: 6.2kV =Electro-mechanical endurance: 6000 =Connection terminal: =Screw terminal =Pillar terminal with calmp =Connection capacity:Rigid conductor up to 25mm2 =Fastening torque: 2.0Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting TOML2-63 Miniature CircuitBreaker A-18 Overall & Installation Dimensions 36 54 72
  • 25. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Easy mounting onto 35mm DIN rail TOM30-63 A-19 Overall & Installation Dimensions Technical Data =Pole No: 1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve: B,C,D =Ultimate short-circuit capacity(lcu): 6KA =Rated frequency: 50/60Hz =Energy limiting class: 3 =Rated impulse withstand voltage: 6.2KV =Electro-mechanical endurance: 6000 =Connection terminal: =Screw terminal =Pillar terminal with clamp =Connection capacity: Rigid conductor up to 25mm2 =Fastening torque: 2.0Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting
  • 26. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Applicable to terminal and pin/fork type busbar connection =Easy mounting onto 35mm DIN rail TOMS1-63 Miniature CircuitBreaker A-20 Overall & Installation Dimensions 17 34 51 78 Technical Data =Pole No: 1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve: B,C,D =Rated short-circuit capacity(lcn): 6kA =Rated frequency: 50/60Hz =Energy limiting calss: 3 =Rated impulse withstand voltage: 6.2kV =Electro-mechanical endurance:6000 =Connection terminal: =Screw terminal =Pillar terminal with calmp =Connection capacity: Rigid conductor up to 25mm2 =Fastening torque: 2.0Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting
  • 27. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Easy mounting onto 35mm DIN rail TOMS2-63 A-21 Overall & Installation Dimensions 36 54 72 Technical Data =Pole No:1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve: B,C,D =Rated short-circuit capacity(lcn): 6kA =Rated frequency: 50/60Hz =Energy limiting calss: 3 =Rated impulse withstand voltage: 6.2kV =Electro-mechanical endurance: 6000 =Connection terminal: =Screw terminal =Pillar terminal with calmp =Connection capacity: Rigid conductor up to 25mm2 =Fastening torque: 2.0Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting
  • 28. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Easy mounting onto 35mm DIN rail Overall & Installation Dimensions TOMS3-63 Miniature CircuitBreaker A-22 Technical Data =Pole No:1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve: B,C,D =Rated short-circuit capacity(lcn): 6kA =Rated frequency: 50/60Hz =Energy limiting calss: 3 =Rated impulse withstand voltage: 6.2kV =Electro-mechanical endurance: 6000 =Connection terminal: =Screw terminal =Pillar terminal with calmp =Connection capacity: Rigid conductor up to 25mm2 =Fastening torque: 2.0Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting
  • 29. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =Protection against both overload and short circuits =Integrated with switched phase and neutral pole =Neutral pole provides no protection against overload and short circuits =Easy mounting onto 35mm DIN rail Overall & Installation Dimensions Technical Data =Pole No: 1P+N =Rated voltage: AC 230 =Rated current(A): 3,6,10,16,20,25,32 =Tripping curve: C =Rated short-circuit capacity: 6KA =Rated service short-circuit capacity(lcs): 6KA =Rated frequency: 50/60Hz =Connection terminal: Pillar terminal with clamp =Connection capacity: Rigid conductor up to 10mm2 =Fastening torque: 1.2Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting TOMP1-32 A-23
  • 30. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =Protection against both overload and short circuits =Integrated with switched phase and neutral pole =Neutral pole provides no protection against overload and short circuits =Easy mounting onto 35mm DIN rail Overall & Installation Dimensions Technical Data =Pole No: 1P+N =Rated voltage: AC 230 =Rated current(A): 3,6,10,16,20,25,32 =Tripping curve: C =Rated short-circuit capacity: 6KA =Rated service short-circuit capacity(lcs): 6KA =Rated frequency: 50/60Hz =Connection terminal: Pillar terminal with clamp =Connection capacity: Rigid conductor up to 10mm2 =Fastening torque: 1.2Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting TOMPG-32 Miniature CircuitBreaker A-24
  • 31. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =Protection against both overload and short circuits =Integrated with switched phase and neutral pole =Neutral pole provides no protection against overload and short circuits =Easy mounting onto 35mm DIN rail Overall & Installation Dimensions Technical Data =Pole No: 1P+N =Rated voltage: AC 230 =Rated current(A): 3,6,10,16,20,25,32 =Tripping curve: C =Rated short-circuit capacity: 6KA =Rated service short-circuit capacity(lcs): 6KA =Rated frequency: 50/60Hz =Connection terminal: Pillar terminal with clamp =Connection capacity: Rigid conductor up to 10mm2 =Fastening torque: 1.2Nm =Installation: =On symmetrical DIN rail 35mm =Panel mounting TOMP10-32 TOMP11-32 A-25 MP10-32 MP11-32
  • 32. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =High short-circuit capacity 25KA =Designed to protect circuit carrying big current up to 125A =Contact position indication =Used as main switch in household and similar installation TOM10-100 Miniature CircuitBreaker A-26 Overall & Installation Dimensions Technical Data =Pole No: 1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 20,25,32,40,50,63,80,100,125 =Tripping curve: C,D =Ultimate short-circuit breaking capacity(lcu): 25KA =Service short-circuit breaking capacity(lcs): 15KA =Rated frequency: 50/60Hz =Rated impulse withstand voltage: 6KV =Electro-mechanical endurance: In 100=10000; In125=8000 =Connection terminal: Pillar terminal with clamp =Connection capacity: =Flexible conductor 35mm2 =Rigid conductor 50mm2 =Installation: =On symmetrical DIN rail 35mm =Panel mounting
  • 33. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Easy mounting onto 35mm DIN rail Overall & Installation Dimensions Technical Data =Pole No: 1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 20,25,32,40,50,63,80,100,125 =Tripping curve: C,D =Ultimate short-circuit breaking capacity(lcu): 25KA =Service short-circuit breaking capacity(lcs): 15KA =Rated frequency: 50/60Hz =Rated impulse withstand voltage: 6KV =Electro-mechanical endurance: In 100=10000; In125=8000 =Connection terminal: Pillar terminal with clamp =Connection capacity: =Flexible conductor 35mm2 =Rigid conductor 50mm2 =Installation: =On symmetrical DIN rail 35mm =Panel mounting 54 81 108 TOM65-100 A-27
  • 34. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =High short-circuit capacity 25KA =Designed to protect circuit carrying big current up to 125A =Contact position indication =Used as main switch in household and similar installation Overall & Installation Dimensions Technical Data =Pole No: 1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 20,25,32,40,50,63,80,100,125 =Tripping curve: C,D =Ultimate short-circuit breaking capacity(lcu): 25KA =Service short-circuit breaking capacity(lcs): 15KA =Rated frequency: 50/60Hz =Rated impulse withstand voltage: 6KV =Electro-mechanical endurance: In 100=10000; In125=8000 =Connection terminal: Pillar terminal with clamp =Connection capacity: =Flexible conductor 35mm2 =Rigid conductor 50mm2 =Installation: =On symmetrical DIN rail 35mm =Panel mounting TOMG1-100 Miniature CircuitBreaker A-28
  • 35. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Easy mounting onto 35mm DIN rail Technical Data =Pole No: 1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 20,25,32,40,50,63,80,100,125 =Tripping curve: C,D =Ultimate short-circuit breaking capacity(lcu): 25KA =Service short-circuit breaking capacity(lcs): 15KA =Rated frequency: 50/60Hz =Rated impulse withstand voltage: 6KV =Electro-mechanical endurance: In 100=10000; In125=8000 =Connection terminal: Pillar terminal with clamp =Connection capacity: =Flexible conductor 35mm2 =Rigid conductor 50mm2 =Installation: =On symmetrical DIN rail 35mm =Panel mounting Overall & Installation Dimensions 27 54 81 108 TOML1-100 A-29
  • 36. Standrad: IEC 60898 Miniature Circuit Breaker Construction and Feature =High short-circuit capacity 25KA =Designed to protect circuit carrying big current up to 125A =Contact position indication =Used as main switch in household and similar installation 54 81 108 Overall & Installation Dimensions Technical Data =Pole No: 1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 20,25,32,40,50,63,80,100,125 =Tripping curve: C,D =Ultimate short-circuit breaking capacity(lcu): 25KA =Service short-circuit breaking capacity(lcs): 15KA =Rated frequency: 50/60Hz =Rated impulse withstand voltage: 6KV =Electro-mechanical endurance: In 100=10000; In125=8000 =Connection terminal: Pillar terminal with clamp =Connection capacity: =Flexible conductor 35mm2 =Rigid conductor 50mm2 =Installation: =On symmetrical DIN rail 35mm =Panel mounting TOMS1-100 Miniature CircuitBreaker A-30
  • 37. Standrad: IEC 60898 Miniature Circuit BreakerMiniature Circuit Breaker Electrical Accessories Specification Q Undervoltage Auxiliary Switch G Overvoltage Auxiliary Switch VAC Mx+Of Shunt Triper Auxiliary Switch MN Under-Voltage Auxiliary Switch Model OF Auxiliary Switch SD Alarm Auxiliary Switch MX Shunt Triper QG Over-/Under-Voltage Auxiliary Switch VDC VDC VAC VAC VAC VDC VAC VDC VAC VAC VDC Rated Voltage (V) Rated Current (A) Installing Size (Times of 9mm Width) 415V - 125V - - 415V°´ - 125V - - 220-415V°´ 24-48V 220-415V°´ 110-220V°´ 24-48V 12-24V 220-415V°´ 110-220V°´ 24-48V 12-24V 170V±5% 280V±5% 170V±5% 280V±5% -... -... -... -... -... TOM10-63 -... -... 1 2 2 2 2 TOM10-63 TOM65-63 TOM71-63 2 1 1 1 2 - 2 2 2 1 1 2 - 2 2 2 MX+OF SD SD OF MX+OF + + + + OF SD OF MX+OF + + + + TOM71-63 + TOM65-63 TOM10-63 =Character: Used to indicate the Off” position of circuit breaker. =Assembly: Installed on the left side of circuit breaker. =Application: It’s used to indicate the fault of equipments like the electric circuir in air-conditioning room or elevator for passenger or goods. SD Alarm Auxiliary Switch Of Auxiliary Switch =Character: Used to indicate the On ” or Off ” position of circuit breaker. =Assembly: Installed on the left side of circuit breaker. =Application: Used to indicate the On”or Off ”position of circuit breaker, the signals can be seen on the case or its front or on the operating stage. It is can be connected with SD alarm auxiliary switch. MX+OF Shunt TripperR =Character: Used for remote control tripping. =Assembly: Installed on the right side of circuit breaker. =Application: it’s applied to break or contact fire fighting alarm system by remote control for electric circuit, it’s also available for remote trip by pressing emergency stop button. Meanwhile, it owns the same functions of OF auxiliary switch. A-31 TOM65-63 415V°´ 230V°´ 24V 48V 130V 415V°´ 230V°´ 24V 48V 130V 220-415V°´ 24-48V 220-415V°´ 110-220V°´ 24-48V 12-24V - - - - 170V±5% 280V±5% 170V±5% 280V±5% -... -... -... -... -... -... -... -... -... TOM71-63 415V°´ 230V°´ 24V 48V 130V 415V°´ 230V°´ 24V - - 220-415V°´ 24-48V 220-415V°´ 110-220V°´ 110-220V 24-60V - - - - 170V±5% 280V±5% 170V±5% 280V±5% -... -... -... -... -... -... -... 44V 48V 3 3 3 44V 44V 480V 3 3 3 - 44V 44V 480V 3 3 3 - 3 - 1 - - 3 - 1 - - TOM10-63 TOM65-63 TOM71-63 3 6 6 2 1 3 6 6 2 1 3 6 4 2 1 2 4 1 - -
  • 38. Standrad: IEC 60898 Miniature Circuit BreakerModular Indicator TOIL1 TOIL2 TOIL3 TOI71TOI70 TOI72 TOI31TOIS1 TOI32 TOI10TOI12(LED) TOI11 Application The modular signal lamp is applicable to circuit with rated voltage 230V~ and frequency 50/60Hz for visual indication and signaling. Construction & Feature =Low service duration, minimum power consumption =Compact design in modular size =Easy installation Technical Data =Rated voltage: 230V AC =Rated frequency: 50/60Hz =Colour: =Connection terminal: pillar terminal with clamp =Connection capacity: rigid conductor 10mm2 =Installation: =On symmetrical DIN rail =Panel mounting Overall & Installation Dimensions Miniature CircuitBreaker Miniature CircuitBreaker Miniature CircuitBreaker A-32
  • 39. Standrad: IEC 60898 Plug-in Miniature Circuit Breakers Construction and Feature =Protection against both overload and short circuit =High short-circuit capacity =Applicable to terminal and pin/fork type busbar connection Technical Data =Pole No: 1,2,3,4 =Rated voltage: AC 230/400V =Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63 =Tripping curve: B,C,D =Rated short-circuit capacity(lcn): 6kA =Rated frequency: 50/60Hz =Energy limiting calss: 3 =Rated impulse withstand voltage: 6.2kV =Electro-mechanical endurance: 6000 =Connection terminal: =Screw terminal =Pillar terminal with calmp =Connection capacity: Rigid conductor up to 25mm2 =Fastening torque: 2.0Nm =Installation: =Clips pan assembly base =Panel mounting Overall & Installation Dimensions TOPI-1 A-33
  • 40. Standrad: IEC 60898 Plug-in Miniature Circuit Breakers Miniature CircuitBreaker Miniature CircuitBreaker Miniature CircuitBreaker Description =For protection against overload and short circuits in the electrical distribution system. =Use in domestic, commercial and light industrial installations. Overall & Installation Dimensions Specification Designation Rating(Amps) Pack Qty. Cat.No. Double pole 2” width Triple pole 3” width Single pole 1” width 10 10 10 10 10 10 10 10 10 10 5 5 5 5 5 5 5 5 5 5 3 3 3 3 3 3 3 3 3 3 5A 10A 15A 20A 30A 40A 50A 60A 75A 100A 5A 10A 15A 20A 30A 40A 50A 60A 75A 100A 5A 10A 15A 20A 30A 40A 50A 60A 75A 100A TOPI-2 105 TOPI-2 110 TOPI-2 115 TOPI-2 120 TOPI-2 130 TOPI-2 140 TOPI-2 150 TOPI-2 160 TOPI-2 175 TOPI-2 1100 TOPI-2 205 TOPI-2 210 TOPI-2 215 TOPI-2 220 TOPI-2 230 TOPI-2 240 TOPI-2 250 TOPI-2 260 TOPI-2 275 TOPI-2 2100 TOPI-2 305 TOPI-2 310 TOPI-2 315 TOPI-2 320 TOPI-2 330 TOPI-2 340 TOPI-2 350 TOPI-2 360 TOPI-2 375 TOPI-2 3100 Technical Data =Conform to IEC 60898,BS 3871-Pt1 =Body material: Bakelite =Rated Current: 5-100A =Rated Voltage: 120,120/240,240/440V AC =Breaking Capacity: 6kA =Frequency: 50/60Hz =Degree of protection:IP20 Connection =Clamp terminal =Mounting: =Clips mounting base TOPI-2 A-34
  • 41. Standrad: IEC 60898 Plug-in Miniature Circuit Breakers TOPI-3 A-35 Description =For protection against overload and short circuits in the electrical distribution system. =Use in domestic, commercial and light industrial installations. Overall & Installation Dimensions Specification Designation Rating(Amps) Pack Qty. Cat.No. Double pole 2” width Triple pole 3” width Single pole 1” width 10 10 10 10 10 10 10 10 10 10 5 5 5 5 5 5 5 5 5 5 3 3 3 3 3 3 3 3 3 3 5A 10A 15A 20A 30A 40A 50A 60A 75A 100A 5A 10A 15A 20A 30A 40A 50A 60A 75A 100A 5A 10A 15A 20A 30A 40A 50A 60A 75A 100A TOPI-3 105 TOPI-3 110 TOPI-3 115 TOPI-3 120 TOPI-3 130 TOPI-3 140 TOPI-3 150 TOPI-3 160 TOPI-3 175 TOPI-3 1100 TOPI-3 205 TOPI-3 210 TOPI-3 215 TOPI-3 220 TOPI-3 230 TOPI-3 240 TOPI-3 250 TOPI-3 260 TOPI-3 275 TOPI-3 2100 TOPI-3 305 TOPI-3 310 TOPI-3 315 TOPI-3 320 TOPI-3 330 TOPI-3 340 TOPI-3 350 TOPI-3 360 TOPI-3 375 TOPI-3 3100 Technical Data =Conform to IEC 60898,BS 3871-Pt1 =Body material: Glassfiber polyester/Bakelite =Rated Current: Bakelite 5-100A =Rated Voltage: 120,120/240,240/440V AC =Breaking Capacity: 6kA =Frequency: 50/60Hz =Degree of protection:IP20 Connection =Clamp terminal =Mounting: =Clips mounting base
  • 42. Standrad: IEC 60898 Plug-in Miniature Circuit Breakers Miniature CircuitBreaker Miniature CircuitBreaker Miniature CircuitBreaker TOPI-4 A-36 Description =For protection against overload and short circuits in the electrical distribution system. =Use in domestic, commercial and light industrial installations. Overall & Installation Dimensions Specification Designation Rating(Amps) Pack Qty. Cat.No. Double pole 2” width Triple pole 3” width Single pole 1” width 10 10 10 10 10 10 10 10 10 10 5 5 5 5 5 5 5 5 5 5 3 3 3 3 3 3 3 3 3 3 5A 10A 15A 20A 30A 40A 50A 60A 75A 100A 5A 10A 15A 20A 30A 40A 50A 60A 75A 100A 5A 10A 15A 20A 30A 40A 50A 60A 75A 100A TOPI-4 105 TOPI-4 110 TOPI-4 115 TOPI-4 120 TOPI-4 130 TOPI-4 140 TOPI-4 150 TOPI-4 160 TOPI-4 175 TOPI-4 1100 TOPI-4 205 TOPI-4 210 TOPI-4 215 TOPI-4 220 TOPI-4 230 TOPI-4 240 TOPI-4 250 TOPI-4 260 TOPI-4 275 TOPI-4 2100 TOPI-4 305 TOPI-4 310 TOPI-4 315 TOPI-4 320 TOPI-4 330 TOPI-4 340 TOPI-4 350 TOPI-4 360 TOPI-4 375 TOPI-4 3100 Technical Data =Conform to IEC 60898,BS 3871-Pt1 =Body material: Bakelite =Rated Current: 5-100A =Rated Voltage: 120,120/240,240/440V AC =Breaking Capacity: 6kA =Frequency: 50/60Hz =Degree of protection:IP20 Connection =Clamp terminal =Mounting: =Clips mounting base
  • 43. Standrad: IEC 60898 Plug-in Miniature Circuit Breakers Description =For protection against overload and short circuits in the electrical distribution system. =Use in domestic, commercial and light industrial installations. Overall & Installation Dimensions Specification Designation Rating(Amps) Pack Qty. Cat.No. Double pole 2” width Triple pole 3” width Single pole 1” width 10 10 10 10 10 10 10 10 10 10 5 5 5 5 5 5 5 5 5 5 3 3 3 3 3 3 3 3 3 3 5A 10A 15A 20A 30A 40A 50A 60A 75A 100A 5A 10A 15A 20A 30A 40A 50A 60A 75A 100A 5A 10A 15A 20A 30A 40A 50A 60A 75A 100A TOPI-5 105 TOPI-5 110 TOPI-5 115 TOPI-5 120 TOPI-5 130 TOPI-5 140 TOPI-5 150 TOPI-5 160 TOPI-5 175 TOPI-51100 TOPI-5 205 TOPI-5 210 TOPI-5 215 TOPI-5 220 TOPI-5 230 TOPI-5 240 TOPI-5 250 TOPI-5 260 TOPI-5 275 TOPI-5 2100 TOPI-5 305 TOPI-5 310 TOPI-5 315 TOPI-5 320 TOPI-5 330 TOPI-5 340 TOPI-5 350 TOPI-5 360 TOPI-5 375 TOPI-5 3100 Technical Data =Conform to IEC 60898,BS 3871-Pt1 =Body material: Bakelite =Rated Current: 5-100A =Rated Voltage: 120,120/240,240/440V AC =Breaking Capacity: 6kA =Frequency: 50/60Hz =Degree of protection:IP20 Connection =Clamp terminal =Mounting: =Clips mounting base TOPI-5 A-37
  • 44. Standrad: IEC 60898 Plug-in Miniature Circuit Breakers Miniature CircuitBreaker Miniature CircuitBreaker Miniature CircuitBreaker Description =For protection against overload and short circuits in the electrical distribution system. =Use in domestic, commercial and light industrial installations. Overall & Installation Dimensions Specification Designation Rating(Amps) Pack Qty. Cat.No. Double pole 2” width Triple pole 3” width Single pole 1” width 10 10 10 10 10 10 10 10 10 10 10 5 5 5 5 5 5 5 5 5 5 5 3 3 3 3 3 3 3 3 3 3 3 6A 10A 16A 20A 25A 30A 40A 50A 60A 75A 100A 6A 10A 16A 20A 25A 30A 40A 50A 60A 75A 100A 6A 10A 16A 20A 25A 30A 40A 50A 60A 75A 100A TOPI-M 3106 TOPI-M 3110 TOPI-M 3116 TOPI-M 3120 TOPI-M 3125 TOPI-M 3130 TOPI-M 3140 TOPI-M 3150 TOPI-M 3160 TOPI-M 3175 TOPI-M 31100 TOPI-M 3206 TOPI-M 3210 TOPI-M 3216 TOPI-M 3220 TOPI-M 3225 TOPI-M 3230 TOPI-M 3240 TOPI-M 3250 TOPI-M 3260 TOPI-M 3275 TOPI-M 32100 TOPI-M 3306 TOPI-M 3310 TOPI-M 3316 TOPI-M 3320 TOPI-M 3325 TOPI-M 3330 TOPI-M 3340 TOPI-M 3350 TOPI-M 3360 TOPI-M 3375 TOPI-M 33100 Technical Data =Conform to IEC 60898,BS 3871-Pt1 =Body material: Bakelite/Glassfiber polyester =Rated Current: 6-100A =Rated Voltage: 120,120/240,240/415V AC =AIC Rating: 10,000 RMS SYM =Degree of protection:IP20 Connection =Pillar type terminal =Mounting =Clips pan assembly base =Plug-in mounting base TOPI-M A-38
  • 45. Standrad: IEC 60898 Plug-in Miniature Circuit Breakers Description =For protection against overload and short circuits in the electrical distribution system. =Use in domestic, commercial and light industrial installations. Overall & Installation Dimensions Specification Designation Rating(Amps) Pack Qty. Cat.No. Double pole 2” width Triple pole 3” width Single pole 1” width 10 10 10 10 10 10 10 10 10 10 10 5 5 5 5 5 5 5 5 5 5 5 3 3 3 3 3 3 3 3 3 3 3 6A 10A 16A 20A 25A 30A 40A 50A 60A 75A 100A 6A 10A 16A 20A 25A 30A 40A 50A 60A 75A 100A 6A 10A 16A 20A 25A 30A 40A 50A 60A 75A 100A TOPI-6 106 TOPI-6 110 TOPI-6 116 TOPI-6 120 TOPI-6 125 TOPI-6 130 TOPI-6 140 TOPI-6 150 TOPI-6 160 - - TOPI-6 206 TOPI-6 210 TOPI-6 216 TOPI-6 220 TOPI-6 225 TOPI-6 230 TOPI-6 240 TOPI-6 250 TOPI-6 260 - - TOPI-6 306 TOPI-6 310 TOPI-6 316 TOPI-6 320 TOPI-6 325 TOPI-6 330 TOPI-6 340 TOPI-6 350 TOPI-6 360 - - Technical Data =Conform to IEC 60898,BS 3871-Pt1 =Body material: Glassfiber polyester/Bakelite =Rated Current: 6-100A =Rated Voltage: 120,120/240,240/415V AC =Breaking Capacity: 6kA =Frequency: 50/60Hz =Degree of protection:IP20 Connection =Pillar type terminal =Mounting =Clips pan assembly base =Plug-in mounting base TOPI-6 106 TOPI-6 110 TOPI-6 116 TOPI-6 120 TOPI-6 125 TOPI-6 130 TOPI-6 140 TOPI-6 150 TOPI-6 160 TOPI-6 175 TOPI-6 1100 TOPI-6 206 TOPI-6 210 TOPI-6 216 TOPI-6 220 TOPI-6 225 TOPI-6 230 TOPI-6 240 TOPI-6 250 TOPI-6 260 TOPI-6 275 TOPI-6 2100 TOPI-6 306 TOPI-6 310 TOPI-6 316 TOPI-6 320 TOPI-6 325 TOPI-6 330 TOPI-6 340 TOPI-6 350 TOPI-6 360 TOPI-6 375 TOPI-6 3100 TOPI-6 A-39
  • 46. Standrad: IEC 60898 Plug-in Miniature Circuit Breakers Miniature CircuitBreaker Miniature CircuitBreaker Miniature CircuitBreaker Description =For protection against overload and short circuits in the electrical distribution system. =Use in domestic, commercial and light industrial installations. Overall & Installation Dimensions Specification Designation Rating(Amps) Pack Qty. Cat.No. Double pole 2” width Triple pole 3” width Single pole 1” width 10 10 10 10 10 10 10 10 10 5 5 5 5 5 5 5 5 5 3 3 3 3 3 3 3 3 3 5A 10A 16A 20A 25A 30A 40A 50A 60A 5A 10A 16A 20A 25A 30A 40A 50A 60A 5A 10A 16A 20A 25A 30A 40A 50A 60A TOPI-7 105 TOPI-7 110 TOPI-7 116 TOPI-7 120 TOPI-7 125 TOPI-7 130 TOPI-7 140 TOPI-7 150 TOPI-7 160 TOPI-7 205 TOPI-7 210 TOPI-7 216 TOPI-7 220 TOPI-7 225 TOPI-7 230 TOPI-7 240 TOPI-7 250 TOPI-7 260 TOPI-7 305 TOPI-7 310 TOPI-7 316 TOPI-7 320 TOPI-7 325 TOPI-7 330 TOPI-7 340 TOPI-7 350 TOPI-7 360 Technical Data =Conform to IEC 60898 BS 3871-Pt1 =Body material: Glassfiber polyester/Bakelite =Rated Current: 5-60A =Rated Voltage: 120,120/240,240/415V AC =Breaking Capacity: 3KA =Frequency: 50/60Hz =Degree of protection:IP20 Connection =Clamp terminal =Mounting =Clips mounting base TOPI-7 A-40
  • 47. Standrad: IEC 60898 Plug-in Miniature Circuit Breakers Description =For protection against overload and short circuits in the electrical distribution system. =Use in domestic, commercial and light industrial installations. Overall & Installation Dimensions Specification Designation Double pole 2” width Triple pole 3” width Single pole 1” width Technical Data =Conform to IEC 60898,UL489 =Body material: Bakelite =Rated Current: 15-100A =Rated Voltage: 120,120/240,240/415VAC =AIC Rating: 10,000 RMS SYM =Degree of protection:IP20 Connection =Pillar type terminal =Mounting =Clips pan assembly base =Plug-in mounting base Rating(Amps) Pack Qty. Cat.No. 10 10 10 10 10 10 10 10 5 5 5 5 5 5 5 5 3 3 3 3 3 3 3 3 15A 20A 30A 40A 50A 60A 75A 100A 15A 20A 30A 40A 50A 60A 75A 100A 15A 20A 30A 40A 50A 60A 75A 100A TOPI-8 1115 TOPI-8 1120 TOPI-8 1130 TOPI-8 1140 TOPI-8 1150 TOPI-8 1160 TOPI-8 1175 TOPI-8 11100 TOPI-8 1215 TOPI-8 1220 TOPI-8 1230 TOPI-8 1240 TOPI-8 1250 TOPI-8 1260 TOPI-8 1275 TOPI-8 12100 TOPI-8 1315 TOPI-8 1320 TOPI-8 1330 TOPI-8 1340 TOPI-8 1350 TOPI-8 1360 TOPI-8 1375 TOPI-8 13100 TOPI-8 A-41
  • 48. Standrad: IEC 60898 Plug-in Miniature Circuit Breakers Miniature CircuitBreaker Miniature CircuitBreaker Miniature CircuitBreaker Description =For protection against overload and short circuits in the electrical distribution system. =Use in domestic, commercial and light industrial installations. Overall & Installation Dimensions Specification Designation Rating(Amps) Pack Qty. Cat.No. Double pole 1” width Single pole 1/2” width 10 10 10 10 10 5 5 5 5 5 15A 20A 30A 40A 50A 15A 20A 30A 40A 50A TOPI-9 1115 TOPI-9 1120 TOPI-9 1130 TOPI-9 1140 TOPI-9 1150 TOPI-9 1215 TOPI-9 1220 TOPI-9 1230 TOPI-9 1240 TOPI-9 1250 Technical Data =Conform to IEC 60898,UL489 =Body material: Bakelite =Rated Current: 15-50A =Rated Voltage: 120,120/240,240/415VAC =AIC Rating: 10,000 RMS SYM =Degree of protection: IP20 Connection =Pillar type terminal =Mounting =Clips pan assembly base =Plug-in mounting base TOPI-9 A-42
  • 49. Standrad: IEC 60898 Plug-in Miniature Circuit Breakers Description =For protection against overload and short circuits in the electrical distribution system. =Use in domestic, commercial and light industrial installations. Overall & Installation Dimensions Specification Designation Rating(Amps) Pack Qty. Cat.No. Double pole 2” width Triple pole 3” width Single pole 1” width 10 10 10 10 10 10 10 10 5 5 5 5 5 5 5 5 3 3 3 3 3 3 3 3 15A 20A 30A 40A 50A 60A 75A 100A 15A 20A 30A 40A 50A 60A 75A 100A 15A 20A 30A 40A 50A 60A 75A 100A TOPI-10 2115 TOPI-10 2120 TOPI-10 2130 TOPI-10 2140 TOPI-10 2150 TOPI-10 2160 TOPI-10 2175 TOPI-10 21100 TOPI-10 2215 TOPI-10 2220 TOPI-10 2230 TOPI-10 2240 TOPI-10 2250 TOPI-10 2260 TOPI-10 2275 TOPI-10 22100 TOPI-10 2315 TOPI-10 2320 TOPI-10 2330 TOPI-10 2340 TOPI-10 2350 TOPI-10 2360 TOPI-10 2375 TOPI-10 23100 Technical Data =Conform to IEC 60898,UL489 =Body material: Bakelite =Rated Current: 15-100A =Rated Voltage: 120,120/240,240/415V AC =AIC Rating: 10,000 RMS SYM =Degree of protection:IP20 Connection =Clamp terminal =Mounting =Clips pan assembly base =Plug-in mounting base TOPI-10 A-43
  • 50. Standrad: IEC 60898 Plug-in Miniature Circuit Breakers Miniature CircuitBreaker Miniature CircuitBreaker Miniature CircuitBreaker Construction and Feature =Protection against overload =High short-circuit capacity Technical Data =Pole No: 2 =Rated voltage: AC 230/400V =Rated current(A): 10,16,20,25,32 =Tripping curve: B,C,D =Ultimate short-circuit capacity(lcu): 4.5KA =Rated frequency: 50/60Hz =Energy limiting class: 3 =Rated impulse withstand voltage: 6.2KV =Electro-mechanical endurance: 4000 =Connection terminal: Pillar terminal with clamp =Connection capacity: Rigid conductor up to 25mm2 =Fastening torque: 2.0Nm =Installation: =Panel mounting TOMT-50 Miniature Circuit Breaker A-44 Overall & Installation Dimensions