SlideShare une entreprise Scribd logo
1  sur  23
Télécharger pour lire hors ligne
PVElite 2005 version                         Quick Start                                 Page 1 of 24

Introduction

The 2005 version of PVElite introduces an updated user interface. The interface is the area on
the screen where you, the user enter all the information such as dimensions, materials and
temperatures etc. For those of you who are familiar with the previous user interface, there are a
number of changes to which you will need to become accustomed.

To make matters clear, we shall deal with the most important features of the new interface, and
show the step by step procedures required to get a model built. We do not cover every aspect of
the data entry, but will provide you enough information for you to understand the basic principles,
after which, you will be able to perform any task. Remember, this is only a ‘Quick Start’
procedure. Further details in operating the program are to be found in the on line documentation.

Also, a little experimentation on your part will soon have you up and running with confidence. So,
let us begin…..

A Quick Look Around

Once you have PVElite up and running, you will see a screen that will look very much like this:




Before getting into any details let us simply build a simple vertical vessel. Our first attempt is a
vessel with 3 parts as shown below:
PVElite 2005 version                        Quick Start                                 Page 2 of 24




                                               Now, you must understand this important principle:

                                               The vessel is built in PVElite from the bottom to the
                                               top. Or, the case of a horizontal vessel, from left to
                                               right. We shall consider building a horizontal vessel
                                               later.

                                               Below we show how the vessel is built component
                                               by component:




This is how the vessel is built:




Let us now built the model of this vessel using PVElite:

Component Buttons

Near the top of the main input window, there is a row of buttons that look like this:




Working from left to right, the components referred are:

       Cylindrical Shell

       Ellipse Head (Ellipsoidal Head)
PVElite 2005 version                         Quick Start                              Page 3 of 24

        Torispherical Head (F & D Head)


        Hemispherical Head

        Conical Head or Transition

        Welded Flat Head


We shall not deal with the remaining icons (buttons) here, as I am sure you are anxious to start
building your first vessel. Before we leave this subject however, if you let your mouse cursor
hover over any of the buttons, you will get a ‘tool tip’, which briefly describes the function of the
button. In the case of the ellipse head button, the tool tip would look like this:

Building the vessel from the bottom up

    1         Bottom head: Click the ellipse head button:

    2         Main shell: Click the cylinder button:

    3         Top head: Click the ellipse head button:

If you now look at the right hand window, you should see the see the 3D model, which will look
somewhat like this:

                                                                                   Window Divider




You will see that you get two models on the screen. On the left we have a 2D model, and on the
right we have a 3D model. By moving the adjustable Window Divider, you can enlarge or
reduce the left or right window; you can slide the window divider left or right. To do this, simply
place your mouse cursor over the frame, hold down the left mouse button, and slide the vertical
window divider left or right to suit your purpose.

What about the dimensions

Now, the actual height and other dimensions are probably not what you want for your vessel.
PVElite made certain assumptions as you built the model, including diameter, thicknesses,
lengths and materials.
PVElite 2005 version                        Quick Start                               Page 4 of 24

Let us look for a moment at the assumptions. Before we look at the dimensions, please click your
mouse on the bottom head, either on the 2D or 3D model. This will select the bottom head as
the current component.

If you look at the 2D model (Left model window), you will see that it has turned a light green color.
It looks like this:




Let us look at the dimension PVElite chose for the current component (light green in the
                                                   1
illustration above. The details will look like this :
                                                                                       2
                                                      Here are the major assumptions :

                                                      Inside Diameter:         96 inches
                                                      Straight Flange:         0.1667 feet – 2 ins
                                                      Finished Thickness:      0.2500 inches
                                                      Internal Corrosion:      0.125 inches
                                                      External Corrosion:      0
                                                      Internal Pressure:       100 psi
                                                      External Pressure:       15 psi
                                                                                    O
                                                      Temperatures:            100 F
                                                      Head Aspect Ratio        2.000 (Aspect Ratio)

                                                      There is other information, but let us now
                                                      make some changes to suit our vessel. First
                                                      we change the dimensions and the pressure:

                                                      New Values:

                                                      Inside Diameter:         60 inches
                                                      Finished Thickness:      0.5000 inches
                                                      Internal Corrosion:      0.0625 inches
                                                      External Corrosion:      0.0625 inches
                                                      Internal Pressure:       120 psi
                                                                                    O
                                                      Temperatures:            200 F




1
 Your screen may look different, but follow along, and it will all become clear
2
  If you are accustomed to working in the metric system, just follow along, we shall address that
situation shortly.
PVElite 2005 version                           Quick Start                              Page 5 of 24


Let us first change the diameter. Follow these simple steps:

Click on the left side of the dimension field so that it looks like this:




Note: The field description is highlighted in blue. Make sure you get this highlight effect.

Now simply enter the new diameter by typing ‘60’, after which the field will look like this:




Now press the <Enter> key on your keyboard twice, and this will move the cursor down to the
next field. Like this:




As you do not want to change the straight flange, press the <Enter> key again, you now get to the
thickness field. As in the case of changing the diameter, enter the new thickness ‘0.5’ and press
the <Enter> key twice. You should be able to complete the entries for you new dimensions, until
your input screen looks like this:




Make sure you have the same dimensions as shown above.

Material Specification

Let us change the material from SA-516 70 to SA 240 316L. This is simple, but follows the steps
carefully.

Click on the material button near the top of the screen. It looks like this:
PVElite 2005 version                       Quick Start                                Page 6 of 24

A new screen opens up that looks like this:




                                                   Grey Bar




In the field called: ‘Material Search String’, type in ‘SA240316L’. Don’t worry about spaces and
dashes. The material in the upper window will have a grey bar highlighting the first instance of the
material. Click on the grey bar to get this screen shown below:
PVElite 2005 version                     Quick Start                            Page 7 of 24




This screen gives you information about the material you have chosen. Simply click on the
‘Select’ button, and the material for your bottom head will have been changes as follows:




Updating the other components in the vessel

So far, we have updated the bottom head with the new data. Also, if you look at the screen you
will this odd looking vessel:
PVElite 2005 version                        Quick Start                               Page 8 of 24

The vessel looks like this because the remaining components (main shell and top head) have not
had their data fields updated. We are going to use a short cut to copy the values for the bottom
to the remaining components.

This is the ‘Share’ button, located near the top of the screen:

Click on this button to get the following screen:




                                                              Notice the boxes that have been
                                                              checked. The checks indicate that
                                                              the items to which they refer will be
                                                              shared with all the other upper
                                                                          3
                                                              components . Make sure you have
                                                              checked all and only the boxes
                                                              shown as being checked on the left.

                                                              Now click the ‘OK’ button, and all the
                                                              components should be updated to
                                                              the new data.




Your model now looks more realistic. You can see that at least the diameter of the bottom head
has been shared with the main shell and top head.




3
    We discuss NODE numbers later. Just follow along for the time being.
PVElite 2005 version                         Quick Start                               Page 9 of 24

The Status Bar at the bottom of the screen

So far, we have only entered the data relevant to our vessel, and produced the model on the
screen. Let us now have a look at what computed data is available to us.

Select the main shell by clicking on it in either the 2D or 3D model. Your screen should look like
this:




                                   If you look at the input data screen to the left, you will see that
                                   the information has been updated to copy the information from
                                   the bottom head.




Look at the bottom of the screen to the status bar. It looks like this:



The status bar gives us a lot of information for the selected component. Let us consider the fields
from left to right:

El# 2 of 3               :        This is component number 2 of 3 components (from the bottom)
Fr: 0.17 to: 4.17 ft     :        This element spans from 0.17 ft to 4.17 ft from the datum line
Up                       :        Do not worry about this field for the time being
Tr: 0.340                :        This is the computed thickness for the internal pressure (120 psi)
Mawp: 206.8              :        This is the MAWP for this element (206.8 psi)
MAPnc: 275.6             :        Maximum allowable pressure new and cold (275.6 psi)
Trext: 0.327             :        The computed thickness for the external pressure
Slen: 23.9 ft            :        The maximum unsupported length for the external pressure

Let us now see what happens when there is a problem with an element.

Go to the ‘Finished Thickness’ field, and change the thickness from 0.5 inches to 0.31 inches.




Now look at the status bar at the bottom of the screen. It now looks like this:



The required thickness for the internal and external pressures now appears in red, indicating that
there is a problem. In our case, the problem is the thickness. It is not adequate.

Change the thickness back to ‘0.5’ inches, to render the status bar values in black lettering.
PVElite 2005 version                        Quick Start                               Page 10 of 24

The Output Processor

Now we have built our simple model, we need to get the complete details of the calculations
performed by PVElite. At the top of the screen there is a button that looks like this:




Click this button. We now get the ‘Output Processor’ as follows:




Your screen may look different, but it can easily be changed to look like the illustration above.

The left window has the heading ‘Report List’. In the right window, we are told ‘There are no
Reports Selected for Viewing’. In the left hand window, click on ‘Internal Pressure Calculations’
The right hand window now shows the results of the item you selected in the left hand window.
The output window now looks as shown below:
PVElite 2005 version                        Quick Start                              Page 11 of 24




You can scroll up and down to look at the complete calculation for the internal pressure
computations.

Generating and Printing the final pressure vessel report

The illustration above shows the output only for the ‘Internal Pressure Calculations’. How do we
get all the information? To select the items you want included in your final report do the following:

Hold down the <Control> button on your keyboard, and while holding it down, click on the items
you want included in the ‘Report List’ (left) window. Your selected items will be highlighted with a
blue background like this (for example):
PVElite 2005 version                        Quick Start                                Page 12 of 24




Once these items are selected, you are ready to generate the report.

If you simply want to send the output to a printer, then you need only click this button (the print to
printer button):

       This will print the report immediately with page numbers and headings on each page.

There are other options. For example, you may find it convenient to send the output to MS-
      TM                            TM
Word . Provided you have MS-Word installed on your computer, this is a simple process.
This time, click this button:
                                                               TM
        This will send the selected output result to MS-Word .

This feature allows you, the user to edit the results, and add your own notes.

You can also send the output to a text file. This time, from the file menu at the top of the screen,
select ‘Print to file’:




You will be asked for a file name. This will be a text file with a filename extension of .txt. You will
                                                                       TM              TM
be able to access this file with any text editor such as Notepad , or MS-Word . When you send
the output to a text file, all the colored text will be lost, and will simply be in black type.
PVElite 2005 version                         Quick Start                                Page 13 of 24

Data Input – Other information

If you look at the bottom of the Data Input screen, you will see a series of tabs that look like this:




If you look carefully at these tabs, you will see that the left most tab is currently selected. The full
name of this tab is: ‘General Input’. This tab refers to the the basic dimensional, pressure,
temperature and material section for the currently selected element. Let us now look at the other
tabs:

If we now click the ‘Heading’ tab we get the following screen:




We have entered form information to demonstrate what can be typed in the first three fields
(Lines 1,2 and 3). In the final output, whether sent to the printer, or to MS-WordTM, the three
lines will appear at the top of each and every page of the report like this:
PVElite 2005 version                         Quick Start                                Page 14 of 24


There is another field also while we have the ‘Heading’ tab selected. This is this one:




Click the little button to the right (see the arrow in the above illustration) to have this screen open
up:




Design Constraints (Global Settings in PVElite)

Enter any information you care to, and it will be printed on the Title Page when sent to the printer
or to a file. This will over write the information PVElite would otherwise print as its default. If in th
output processor you select the title page, it will now look like this:




Let us now investigat the the ‘Design Constraints Tab’. It is this one:
PVElite 2005 version                         Quick Start                               Page 15 of 24

This tab allows us to set the default values for the entire vessel. Let us look at some of the main
fields:

                                                      By entering the pressures and temperatures
                                                      in these first four fields, PVElite will use these
                                                      values as the default values for the whole
                                                      vessel. This saves time later.



The datum field.



If you look at your 3D model on the screen it will look something likd this:

                                                             PVElite has located the datum line at
                                                             the tangent line of the bottom head. We
                                                             can change the location of the datum
                                                             line at anytime to move it to a more
                                                             convenient location to suit your
                                                             purpose. Let us do this now to see
                                                             what happens:



Set the datum line to 3 feet up from its current location:



The model now looks like this:




Once you have a skirt attached to the bottom of the vessel you may wish to mover the datum line
to the bottom of the skirt as it may be more convenient.

Hydrotest Type and Position of the hydrotest:




From the drop down box, you can tell PVElite how it must calculate the hydrotest pressure
PVElite 2005 version                        Quick Start                               Page 16 of 24

The next box also allows you to let PVElite know which position the vessel will be ini during the
hydrotest:

These are the choices you have available to you:




Tall towers for example, are usually hydrotested in the horizontal position. PVElite has to
compute the hydrostatic pressure from the water in the vessel at hydrotest time. If the vessel is
tested in the vertical position, the pressure at the bottom of the vessel will be greater than if the
vessel is tested in the horizontal position. Give careful consideration to the position that is
appropriate to your situation.

Nozzle Projections:




Enter the nozzle projection from the surface of the vessel pressure envelope. This information is
used by PVElite to compute any extra liquid level where the nozzle project higher than the vessel
envelope. This information is fairly straight forward, and needs no further explanation.

Minimum Metal Temperature:




Enter the minimum metal temperature. This temperature will be applied to the whole vessel. In
the case of carbon steel vessels, this temperature is very important. Where vessels are operating
at low temperature, the material and weldments may need to be impact tested (UG-34 and UCS
66 of ASME Division 1). Also, using normalized materials may enhance the low temperature
properties of the materials of construction.

PVElite computes the minimum allowable metal temperature, and compares it with the required
minimum metal temperature.

Flange Distance to Top:




Enter the distance from the centerline/face of flange to the top of the vessel. This value will be
used in case the flanges govern the MAP of the vessel. If the vessel is being in the vertical
position and the vessel is being tested in accordance with UG-99 c, this value will used in
conjunction with the flange projection from top to determine the total static head to subtract for the
type hydrostatic test.
PVElite 2005 version                      Quick Start                             Page 17 of 24

Construction Type:




The meanings are fairly obvious. It is most likely that the default ‘Welded’ is used about 99.9 %
of the time. That is why it is the default setting.

Service Type:




The type of service is specific to ASME Section VIII, Division 1. The code (Section UW) imposes
special requirements for vessels in lethal and steam services. This is usually left at the default
value of ‘None’

Degree of Radiography:




From the drop down box, click on the appropriate degree of radiography. PVElite does NOT
automatically set the joint factor (E) from this global selection.

Design Code:

PVEite allows the user to perform vessel calculations in several pressure vessel codes.




The following design codes are supported by PVElite:

            •   ASME Section VIII, Division 1
            •   ASME Section VIII, Division 2
            •   The British PD 5500
            •   The European EN 13445
PVElite 2005 version                       Quick Start                             Page 18 of 24

Once a code is selected, the user will have to re-select the materials, as each code has its own
design stress tables.

User Defined MAWP:




The ASME Section VIII, Division 1 code determes the Maximim Allowable Working Pressure
(MAWP) the vessel is able to sustain. PVElite uses the MAWP to compute the shop hydrotest
pressure and the required reinforcement for nozzle reinforcement. The code (Division 1) allows
the designer to set the MAWP to the design pressure. If you want the MAWP to be limited to a
paraticular value, then PVElite will use this value instead of the computed MAWP in its
computations. It is possible that the MAWP will exceed the allowable pressure rating of the vessel
flanges. The computed MAWP could for example force the design to increase the flanges (for
example) from Class 150 to Class 300, which could be expensive.

User Defined MAPnc:




In the cold condition, the flange ratings again could be exceeded. The user can set his own value
of Maximum Allowable Pressure New and Cold.

User Defined Hydro. Pressure:




In the case of ASME Division 1, the hydrotest pressure is computed per UG-99 with varying
degrees of severity. The user can reduce or change the hydrotest pressure. PVElite computes
the actual stresses existing in the various components during the shop hydrotest. The stresses
can be reduced by the user by setting the test pressure to a lower value.

Aditional Operating Static Pressure:




If for example, the vessel had a piping system attached, the liquid contained in the piping could
add to the design pressure. If there are other factors that raise the pressure during the operating
condition, this added pressure can be catered for.

Use Higher Longitudinal Stress:




The ASME Code (Section VIII, Division 1, Paragraph UG-23(d)) allows the allowable stress for
the combination of earthquake loading, or wind loading with other loadings to be increased by a
factor of 1.2. if the operating condition is below the following temperatures. To take advantage of
this concession, check the box as shown above. Seismic and wind loads are considered to be
occasion, whereas pressure loading is considered to be sustained.
PVElite 2005 version                         Quick Start                                Page 19 of 24

Hydrotest, Allow Unmodified:




By default PVElite uses the hydrotest stress times the allowable stress increase factor for
occasional loads (times the joint efficiency. on the tensile side). However, for stainless steel
vessels this value is often limited to 0.9 times the yield stress. Then this field should checked in
order to use the defined value without any modification.

Consider Vortex Shedding:




If this box is checked PVElite will perform vortex shedding calculations on the vessel. This
method is documented in the National Building Code of Canada and in texts on wind engineering.
If are analyzing a tall slender vessel it may be susceptible to vortex shedding. PVElite will
compute the likelihood of this occurrence based on the research of Zorilla and Mahajan. If there is
no possibility of wind vibration and you have this box checked, PVElite will warn you that
unrealistic (high) stresses will result and give you the option to turn this calculation off at run time.

Is this a Heat Exchanger:




Note: This check box is optional.

If the Dimensional Solutions 3D file interface button is checked see above right), PVElite will write
out a text file that contains the geometry and loading information for this particular vessel design.
If this box is checked, the program will simply write this data out to the Jobname.ini file created in
the current working directory. More information about the Dimensional Solutions product line can
be found on their website at the following web site: www.Dimsoln.com

To completely define an exchanger it is necessary to enter in the required information regarding
the tubes, tubesheets and the floating head (if any). With the exchanger data, PVElite can then
compute the weights and required thicknesses of the exchanger components

Corroded Hydrotest:




By default PVElite uses the uncorroded wall thickness when the stresses on the elements during
the hydrotest are computed. In some cases it is necessary to hydrotest the vessel after it has
corroded. If you wish to use a corroded thickness in the calculations, check this box. Please note
that longitudinal stresses due to Hydrostatic test pressure will also be computed in a similar
manner.
PVElite 2005 version                        Quick Start                              Page 20 of 24


Hydrotest Allowable 90% Yield:



For ASME Division 1, the hydrotest allowable stress is 1.3 times the ambient allowable stress for
the material. When the vessel is tested, the largest circumferential stress should not exceed this
value. If you wish to use 90 percent of the ambient yield stress instead of 1.3 the ambient
allowable, then you can check this box.

ASME Steel Stack:




PVElite will analyze steel stacks in accordance with ASME STS-2000. A further discussion is
outside the scope of this Quick Sart document.

Let PVElite automatically select thickness / Stiffening Rings etc.:




If any of the items is set to yes, PVElite will correct the item should it fail in the analysis. For
example, if ‘Select Wall Thickness for Internal Pressure’ be set to ‘Yes’, PVElite will automatically
increase the thickness of a component should it not be thick enough.

By now, you should be able to figure out what the rest of the tabs at the bottom of the data input
screen do. A little experimentation will make their use quite cliear.

Building a Horizontal Vessel – Start a new vessel

As discussed above, the vessel is built either from bottom to top, or from left to right. Let us
quickly build a simple horizontal vessel:

On the input data screen start with the first head. Simply click on this button :

The head will look like this:




Clearly, PVElite has assumed you are building a vertical vessel, and this is the bottom head. We
need to Flip this head to enable us to build a horizontal vessel To do this, locate the ‘Flip’ button
which looks like this:




Click on this button, and the head will then be turn clockwise through 90 degress to look like this:
PVElite 2005 version                      Quick Start                            Page 21 of 24




Now add the cylindrical shell and right hand head (as shown in the beginning of this document),
until the vessel looks like this:




The rest of the design is can be completed from here.

Inserting a Component

As discussed above, a vessel is built from the bottom to the top, or from left to right. Often a
component is missing, and has to be inserted into the model. The procedure is very simple.

These are the steps you must take:

    •   Select the item on your model (click on the component in the 2D model is easiest). The
        selected component will turn light green.
    •   Near the top of the screen click on the insert button:
    •   A new screen opens up:




    •   In the upper frame select the type of element you wish to insert
PVElite 2005 version                       Quick Start                             Page 22 of 24

    •   In the lower frame, determine if you want the inserted element to inserted before (below
        or to the left) or after (above or to the right) of the formerly selected element.
    •   If you experiment, it will all become quite cliear.

Deleting a Component

The steps are very simple:

    •   Select the item you wish to delete (make sure there are no nozzles in this element). The
        selected element will turn light green in the 2D model.
    •   Click the delete button:
    •   Then follow the on screen instructions.

What is meant by Node Numbers

This is a very important topic. All elements that make up a vessel exist between nodes. At the
top of the input screen you will see a box that looks lke this:




Every main element (not attachments such as nozzles etc) has two nodes. Consider these two
vessels shown below:




Notice that every element from the bottom to the top, or from the left to the right exists between
two node numbers. There is a ‘From Node’, and there is a ‘To Node’. In the case of the bottom
(or left) head the nodes are situated at the tangent line and the weld line.

The PVElite Help System

PVElite has an extensive on screen help system. Let us once your cursor is sitting in a particular
field, and you want information about that field. You can press the ‘F1’ key on your keyboard, and
instant help is availlable. Also, the complete user manual is available at any time you need it. To
ger the on screen user manual, click on ‘Help’ in the menu line, and select ‘View Documentation’
PVElite 2005 version                  Quick Start                          Page 23 of 24


Conclusion

This brings us to the end of our Quick Start discussion. If you work you way through this
document, you will be able to build just about any type of vessel you please.

Contenu connexe

Tendances

Design of pressure vessel
Design of pressure vesselDesign of pressure vessel
Design of pressure vesselKJ Savaliya
 
Pressure vessel manufacturing
Pressure vessel manufacturingPressure vessel manufacturing
Pressure vessel manufacturingphysics101
 
Summary of pressure vessel 1
Summary of pressure vessel 1Summary of pressure vessel 1
Summary of pressure vessel 1Mohamed Basyoni
 
Static and Fatigue Analysis of Pressure Vessel as per ASME Codes
Static and Fatigue Analysis of Pressure Vessel as per ASME CodesStatic and Fatigue Analysis of Pressure Vessel as per ASME Codes
Static and Fatigue Analysis of Pressure Vessel as per ASME CodesUtsav Patel
 
Design Of Pressure Vessel
Design Of  Pressure VesselDesign Of  Pressure Vessel
Design Of Pressure VesselFasih Khan
 
Piping handbook
Piping handbookPiping handbook
Piping handbookpdmsguy
 
Asme viii Div. 1 presentation rev.0
Asme viii Div. 1  presentation   rev.0Asme viii Div. 1  presentation   rev.0
Asme viii Div. 1 presentation rev.0Mohammad Mahrous
 
Piping design and flexibility analysis
Piping design and flexibility analysisPiping design and flexibility analysis
Piping design and flexibility analysisSarath Krishnakumar
 
AVEVA Everything 3D
AVEVA Everything 3DAVEVA Everything 3D
AVEVA Everything 3DHadi Karimi
 
Floating head heat exchanger components &amp; maintenance
Floating head heat exchanger components &amp; maintenanceFloating head heat exchanger components &amp; maintenance
Floating head heat exchanger components &amp; maintenanceKarnav Rana
 
pipe stress analysis for piping engineering
pipe stress analysis for piping engineeringpipe stress analysis for piping engineering
pipe stress analysis for piping engineeringYoga Sathish
 

Tendances (20)

Design of pressure vessel
Design of pressure vesselDesign of pressure vessel
Design of pressure vessel
 
Wellhead Valves Technical Data
Wellhead Valves Technical DataWellhead Valves Technical Data
Wellhead Valves Technical Data
 
Pressure vessel manufacturing
Pressure vessel manufacturingPressure vessel manufacturing
Pressure vessel manufacturing
 
Summary of pressure vessel 1
Summary of pressure vessel 1Summary of pressure vessel 1
Summary of pressure vessel 1
 
Piping ppt1
Piping ppt1Piping ppt1
Piping ppt1
 
Static and Fatigue Analysis of Pressure Vessel as per ASME Codes
Static and Fatigue Analysis of Pressure Vessel as per ASME CodesStatic and Fatigue Analysis of Pressure Vessel as per ASME Codes
Static and Fatigue Analysis of Pressure Vessel as per ASME Codes
 
O ring Seals
O ring SealsO ring Seals
O ring Seals
 
Design Of Pressure Vessel
Design Of  Pressure VesselDesign Of  Pressure Vessel
Design Of Pressure Vessel
 
Introduction to piping design
Introduction to piping designIntroduction to piping design
Introduction to piping design
 
Engineering & Design of Pipe Supports
Engineering & Design of Pipe SupportsEngineering & Design of Pipe Supports
Engineering & Design of Pipe Supports
 
Piping handbook
Piping handbookPiping handbook
Piping handbook
 
Asme viii Div. 1 presentation rev.0
Asme viii Div. 1  presentation   rev.0Asme viii Div. 1  presentation   rev.0
Asme viii Div. 1 presentation rev.0
 
metal_casting
 metal_casting metal_casting
metal_casting
 
pressure vessel, its types and uses
pressure vessel, its types and usespressure vessel, its types and uses
pressure vessel, its types and uses
 
Piping design and flexibility analysis
Piping design and flexibility analysisPiping design and flexibility analysis
Piping design and flexibility analysis
 
Presentation on SECVIII
Presentation on SECVIIIPresentation on SECVIII
Presentation on SECVIII
 
Pv elite v8
Pv elite v8 Pv elite v8
Pv elite v8
 
AVEVA Everything 3D
AVEVA Everything 3DAVEVA Everything 3D
AVEVA Everything 3D
 
Floating head heat exchanger components &amp; maintenance
Floating head heat exchanger components &amp; maintenanceFloating head heat exchanger components &amp; maintenance
Floating head heat exchanger components &amp; maintenance
 
pipe stress analysis for piping engineering
pipe stress analysis for piping engineeringpipe stress analysis for piping engineering
pipe stress analysis for piping engineering
 

En vedette

Pressure vessels
Pressure vessels  Pressure vessels
Pressure vessels GPTraining
 
Proyecto de recipiente a presión mediante PVElite, con ASME y Dir. 97/23/CEE
Proyecto de recipiente a presión mediante PVElite, con ASME y Dir. 97/23/CEEProyecto de recipiente a presión mediante PVElite, con ASME y Dir. 97/23/CEE
Proyecto de recipiente a presión mediante PVElite, con ASME y Dir. 97/23/CEEVega Phil
 
Pvp2005 71123
Pvp2005 71123Pvp2005 71123
Pvp2005 71123wangzh2k
 
Fluidos richard w greene- compresores y bombas
Fluidos richard w greene- compresores y bombasFluidos richard w greene- compresores y bombas
Fluidos richard w greene- compresores y bombascarlcox
 
Design & analysis of thick pressure vessels 1
Design & analysis of thick pressure vessels 1Design & analysis of thick pressure vessels 1
Design & analysis of thick pressure vessels 1Sumit Dharmarao
 
Libraries quick build_model
Libraries quick build_modelLibraries quick build_model
Libraries quick build_modelGem Gem
 
Válvulas, selección, uso y mantenimiento richard w. greene
Válvulas, selección, uso y mantenimiento   richard w. greeneVálvulas, selección, uso y mantenimiento   richard w. greene
Válvulas, selección, uso y mantenimiento richard w. greeneEduardo Sagredo
 
Compresores - Maquinas y Equipos Térmicos
Compresores - Maquinas y Equipos TérmicosCompresores - Maquinas y Equipos Térmicos
Compresores - Maquinas y Equipos TérmicosOscaar Diaz
 
Design by Analysis - A general guideline for pressure vessel
Design by Analysis - A general guideline for pressure vesselDesign by Analysis - A general guideline for pressure vessel
Design by Analysis - A general guideline for pressure vesselAnalyzeForSafety
 
Teoria diseño y aplicaciones de bombas
Teoria diseño y aplicaciones de bombasTeoria diseño y aplicaciones de bombas
Teoria diseño y aplicaciones de bombasEduardo Sagredo
 

En vedette (19)

Pressure vessels
Pressure vessels  Pressure vessels
Pressure vessels
 
Vessel design
Vessel designVessel design
Vessel design
 
Proyecto de recipiente a presión mediante PVElite, con ASME y Dir. 97/23/CEE
Proyecto de recipiente a presión mediante PVElite, con ASME y Dir. 97/23/CEEProyecto de recipiente a presión mediante PVElite, con ASME y Dir. 97/23/CEE
Proyecto de recipiente a presión mediante PVElite, con ASME y Dir. 97/23/CEE
 
Pvp2005 71123
Pvp2005 71123Pvp2005 71123
Pvp2005 71123
 
Recipiente
RecipienteRecipiente
Recipiente
 
Fluidos richard w greene- compresores y bombas
Fluidos richard w greene- compresores y bombasFluidos richard w greene- compresores y bombas
Fluidos richard w greene- compresores y bombas
 
Design & analysis of thick pressure vessels 1
Design & analysis of thick pressure vessels 1Design & analysis of thick pressure vessels 1
Design & analysis of thick pressure vessels 1
 
Compresores richard w. greene
Compresores   richard w. greeneCompresores   richard w. greene
Compresores richard w. greene
 
Compresores
CompresoresCompresores
Compresores
 
Base ring analysis
Base ring analysisBase ring analysis
Base ring analysis
 
Libraries quick build_model
Libraries quick build_modelLibraries quick build_model
Libraries quick build_model
 
Hungary
HungaryHungary
Hungary
 
Válvulas, selección, uso y mantenimiento richard w. greene
Válvulas, selección, uso y mantenimiento   richard w. greeneVálvulas, selección, uso y mantenimiento   richard w. greene
Válvulas, selección, uso y mantenimiento richard w. greene
 
Compresores - Maquinas y Equipos Térmicos
Compresores - Maquinas y Equipos TérmicosCompresores - Maquinas y Equipos Térmicos
Compresores - Maquinas y Equipos Térmicos
 
Design by Analysis - A general guideline for pressure vessel
Design by Analysis - A general guideline for pressure vesselDesign by Analysis - A general guideline for pressure vessel
Design by Analysis - A general guideline for pressure vessel
 
Pressure vessel types
Pressure vessel typesPressure vessel types
Pressure vessel types
 
Pressure vessels
Pressure vesselsPressure vessels
Pressure vessels
 
Teoria diseño y aplicaciones de bombas
Teoria diseño y aplicaciones de bombasTeoria diseño y aplicaciones de bombas
Teoria diseño y aplicaciones de bombas
 
calculo de recipientes a presion
calculo de recipientes a presioncalculo de recipientes a presion
calculo de recipientes a presion
 

Similaire à 54414198 tutorial-pv-elite-2005 2

ABC Consolidated Financial InfoABC Companys current financial inf.docx
ABC Consolidated Financial InfoABC Companys current financial inf.docxABC Consolidated Financial InfoABC Companys current financial inf.docx
ABC Consolidated Financial InfoABC Companys current financial inf.docxransayo
 
User guide to power point
User guide to power pointUser guide to power point
User guide to power pointmvandamme3
 
Ankit Phadia Hacking tools (1)
Ankit Phadia Hacking tools (1)Ankit Phadia Hacking tools (1)
Ankit Phadia Hacking tools (1)Chandra Pr. Singh
 
Sheet metal design
Sheet metal designSheet metal design
Sheet metal designHien Dinh
 
Concrete bent with_nonprismatic_cap_beam
Concrete bent with_nonprismatic_cap_beamConcrete bent with_nonprismatic_cap_beam
Concrete bent with_nonprismatic_cap_beamubaidinfo
 
Intro to Inventor with MugTree
Intro to Inventor with MugTreeIntro to Inventor with MugTree
Intro to Inventor with MugTreekrysia
 
Mv process log form 2019 (2)
Mv process log form 2019 (2)Mv process log form 2019 (2)
Mv process log form 2019 (2)EllieJones40
 
VB.NET programming
VB.NET programmingVB.NET programming
VB.NET programmingElrey Belga
 
SAP2000 Piperack Tutorial 2010.pdf
SAP2000 Piperack Tutorial 2010.pdfSAP2000 Piperack Tutorial 2010.pdf
SAP2000 Piperack Tutorial 2010.pdfsdads1
 
AssetsAsset IDCustomer IDItemModelSerial NumberCategoryIn Service .docx
AssetsAsset IDCustomer IDItemModelSerial NumberCategoryIn Service .docxAssetsAsset IDCustomer IDItemModelSerial NumberCategoryIn Service .docx
AssetsAsset IDCustomer IDItemModelSerial NumberCategoryIn Service .docxfredharris32
 
SAP Training ( PS , Material PR , Service PR ,Cost Planning , Budgeting , PO...
SAP Training ( PS , Material PR , Service PR ,Cost Planning , Budgeting ,  PO...SAP Training ( PS , Material PR , Service PR ,Cost Planning , Budgeting ,  PO...
SAP Training ( PS , Material PR , Service PR ,Cost Planning , Budgeting , PO...Soumya De
 
Sap ps training material
Sap ps training materialSap ps training material
Sap ps training materialSoumya De
 
Xmastcamcribboard
XmastcamcribboardXmastcamcribboard
Xmastcamcribboarddoglupo
 
Primavera manual tutorial book
Primavera manual tutorial bookPrimavera manual tutorial book
Primavera manual tutorial bookThomas Britto
 
Primavera manual tutorial book
Primavera manual tutorial bookPrimavera manual tutorial book
Primavera manual tutorial bookThomas Britto
 
Knowledgeware
KnowledgewareKnowledgeware
Knowledgewaremusawi
 
6.develop a synchronous service for caliculation of factorial of a given number
6.develop a synchronous service for caliculation of factorial of a given number6.develop a synchronous service for caliculation of factorial of a given number
6.develop a synchronous service for caliculation of factorial of a given numberxavier john
 
Windows 7 tips tricks
Windows 7 tips tricksWindows 7 tips tricks
Windows 7 tips trickschenley
 

Similaire à 54414198 tutorial-pv-elite-2005 2 (20)

ABC Consolidated Financial InfoABC Companys current financial inf.docx
ABC Consolidated Financial InfoABC Companys current financial inf.docxABC Consolidated Financial InfoABC Companys current financial inf.docx
ABC Consolidated Financial InfoABC Companys current financial inf.docx
 
User guide to power point
User guide to power pointUser guide to power point
User guide to power point
 
Ankit Phadia Hacking tools (1)
Ankit Phadia Hacking tools (1)Ankit Phadia Hacking tools (1)
Ankit Phadia Hacking tools (1)
 
Sheet metal design
Sheet metal designSheet metal design
Sheet metal design
 
Concrete bent with_nonprismatic_cap_beam
Concrete bent with_nonprismatic_cap_beamConcrete bent with_nonprismatic_cap_beam
Concrete bent with_nonprismatic_cap_beam
 
Intro to Inventor with MugTree
Intro to Inventor with MugTreeIntro to Inventor with MugTree
Intro to Inventor with MugTree
 
A Primavera Tutorial
A Primavera TutorialA Primavera Tutorial
A Primavera Tutorial
 
Mv process log form 2019 (2)
Mv process log form 2019 (2)Mv process log form 2019 (2)
Mv process log form 2019 (2)
 
VB.NET programming
VB.NET programmingVB.NET programming
VB.NET programming
 
SAP2000 Piperack Tutorial 2010.pdf
SAP2000 Piperack Tutorial 2010.pdfSAP2000 Piperack Tutorial 2010.pdf
SAP2000 Piperack Tutorial 2010.pdf
 
Fusion 360 training course
Fusion 360 training courseFusion 360 training course
Fusion 360 training course
 
AssetsAsset IDCustomer IDItemModelSerial NumberCategoryIn Service .docx
AssetsAsset IDCustomer IDItemModelSerial NumberCategoryIn Service .docxAssetsAsset IDCustomer IDItemModelSerial NumberCategoryIn Service .docx
AssetsAsset IDCustomer IDItemModelSerial NumberCategoryIn Service .docx
 
SAP Training ( PS , Material PR , Service PR ,Cost Planning , Budgeting , PO...
SAP Training ( PS , Material PR , Service PR ,Cost Planning , Budgeting ,  PO...SAP Training ( PS , Material PR , Service PR ,Cost Planning , Budgeting ,  PO...
SAP Training ( PS , Material PR , Service PR ,Cost Planning , Budgeting , PO...
 
Sap ps training material
Sap ps training materialSap ps training material
Sap ps training material
 
Xmastcamcribboard
XmastcamcribboardXmastcamcribboard
Xmastcamcribboard
 
Primavera manual tutorial book
Primavera manual tutorial bookPrimavera manual tutorial book
Primavera manual tutorial book
 
Primavera manual tutorial book
Primavera manual tutorial bookPrimavera manual tutorial book
Primavera manual tutorial book
 
Knowledgeware
KnowledgewareKnowledgeware
Knowledgeware
 
6.develop a synchronous service for caliculation of factorial of a given number
6.develop a synchronous service for caliculation of factorial of a given number6.develop a synchronous service for caliculation of factorial of a given number
6.develop a synchronous service for caliculation of factorial of a given number
 
Windows 7 tips tricks
Windows 7 tips tricksWindows 7 tips tricks
Windows 7 tips tricks
 

54414198 tutorial-pv-elite-2005 2

  • 1. PVElite 2005 version Quick Start Page 1 of 24 Introduction The 2005 version of PVElite introduces an updated user interface. The interface is the area on the screen where you, the user enter all the information such as dimensions, materials and temperatures etc. For those of you who are familiar with the previous user interface, there are a number of changes to which you will need to become accustomed. To make matters clear, we shall deal with the most important features of the new interface, and show the step by step procedures required to get a model built. We do not cover every aspect of the data entry, but will provide you enough information for you to understand the basic principles, after which, you will be able to perform any task. Remember, this is only a ‘Quick Start’ procedure. Further details in operating the program are to be found in the on line documentation. Also, a little experimentation on your part will soon have you up and running with confidence. So, let us begin….. A Quick Look Around Once you have PVElite up and running, you will see a screen that will look very much like this: Before getting into any details let us simply build a simple vertical vessel. Our first attempt is a vessel with 3 parts as shown below:
  • 2. PVElite 2005 version Quick Start Page 2 of 24 Now, you must understand this important principle: The vessel is built in PVElite from the bottom to the top. Or, the case of a horizontal vessel, from left to right. We shall consider building a horizontal vessel later. Below we show how the vessel is built component by component: This is how the vessel is built: Let us now built the model of this vessel using PVElite: Component Buttons Near the top of the main input window, there is a row of buttons that look like this: Working from left to right, the components referred are: Cylindrical Shell Ellipse Head (Ellipsoidal Head)
  • 3. PVElite 2005 version Quick Start Page 3 of 24 Torispherical Head (F & D Head) Hemispherical Head Conical Head or Transition Welded Flat Head We shall not deal with the remaining icons (buttons) here, as I am sure you are anxious to start building your first vessel. Before we leave this subject however, if you let your mouse cursor hover over any of the buttons, you will get a ‘tool tip’, which briefly describes the function of the button. In the case of the ellipse head button, the tool tip would look like this: Building the vessel from the bottom up 1 Bottom head: Click the ellipse head button: 2 Main shell: Click the cylinder button: 3 Top head: Click the ellipse head button: If you now look at the right hand window, you should see the see the 3D model, which will look somewhat like this: Window Divider You will see that you get two models on the screen. On the left we have a 2D model, and on the right we have a 3D model. By moving the adjustable Window Divider, you can enlarge or reduce the left or right window; you can slide the window divider left or right. To do this, simply place your mouse cursor over the frame, hold down the left mouse button, and slide the vertical window divider left or right to suit your purpose. What about the dimensions Now, the actual height and other dimensions are probably not what you want for your vessel. PVElite made certain assumptions as you built the model, including diameter, thicknesses, lengths and materials.
  • 4. PVElite 2005 version Quick Start Page 4 of 24 Let us look for a moment at the assumptions. Before we look at the dimensions, please click your mouse on the bottom head, either on the 2D or 3D model. This will select the bottom head as the current component. If you look at the 2D model (Left model window), you will see that it has turned a light green color. It looks like this: Let us look at the dimension PVElite chose for the current component (light green in the 1 illustration above. The details will look like this : 2 Here are the major assumptions : Inside Diameter: 96 inches Straight Flange: 0.1667 feet – 2 ins Finished Thickness: 0.2500 inches Internal Corrosion: 0.125 inches External Corrosion: 0 Internal Pressure: 100 psi External Pressure: 15 psi O Temperatures: 100 F Head Aspect Ratio 2.000 (Aspect Ratio) There is other information, but let us now make some changes to suit our vessel. First we change the dimensions and the pressure: New Values: Inside Diameter: 60 inches Finished Thickness: 0.5000 inches Internal Corrosion: 0.0625 inches External Corrosion: 0.0625 inches Internal Pressure: 120 psi O Temperatures: 200 F 1 Your screen may look different, but follow along, and it will all become clear 2 If you are accustomed to working in the metric system, just follow along, we shall address that situation shortly.
  • 5. PVElite 2005 version Quick Start Page 5 of 24 Let us first change the diameter. Follow these simple steps: Click on the left side of the dimension field so that it looks like this: Note: The field description is highlighted in blue. Make sure you get this highlight effect. Now simply enter the new diameter by typing ‘60’, after which the field will look like this: Now press the <Enter> key on your keyboard twice, and this will move the cursor down to the next field. Like this: As you do not want to change the straight flange, press the <Enter> key again, you now get to the thickness field. As in the case of changing the diameter, enter the new thickness ‘0.5’ and press the <Enter> key twice. You should be able to complete the entries for you new dimensions, until your input screen looks like this: Make sure you have the same dimensions as shown above. Material Specification Let us change the material from SA-516 70 to SA 240 316L. This is simple, but follows the steps carefully. Click on the material button near the top of the screen. It looks like this:
  • 6. PVElite 2005 version Quick Start Page 6 of 24 A new screen opens up that looks like this: Grey Bar In the field called: ‘Material Search String’, type in ‘SA240316L’. Don’t worry about spaces and dashes. The material in the upper window will have a grey bar highlighting the first instance of the material. Click on the grey bar to get this screen shown below:
  • 7. PVElite 2005 version Quick Start Page 7 of 24 This screen gives you information about the material you have chosen. Simply click on the ‘Select’ button, and the material for your bottom head will have been changes as follows: Updating the other components in the vessel So far, we have updated the bottom head with the new data. Also, if you look at the screen you will this odd looking vessel:
  • 8. PVElite 2005 version Quick Start Page 8 of 24 The vessel looks like this because the remaining components (main shell and top head) have not had their data fields updated. We are going to use a short cut to copy the values for the bottom to the remaining components. This is the ‘Share’ button, located near the top of the screen: Click on this button to get the following screen: Notice the boxes that have been checked. The checks indicate that the items to which they refer will be shared with all the other upper 3 components . Make sure you have checked all and only the boxes shown as being checked on the left. Now click the ‘OK’ button, and all the components should be updated to the new data. Your model now looks more realistic. You can see that at least the diameter of the bottom head has been shared with the main shell and top head. 3 We discuss NODE numbers later. Just follow along for the time being.
  • 9. PVElite 2005 version Quick Start Page 9 of 24 The Status Bar at the bottom of the screen So far, we have only entered the data relevant to our vessel, and produced the model on the screen. Let us now have a look at what computed data is available to us. Select the main shell by clicking on it in either the 2D or 3D model. Your screen should look like this: If you look at the input data screen to the left, you will see that the information has been updated to copy the information from the bottom head. Look at the bottom of the screen to the status bar. It looks like this: The status bar gives us a lot of information for the selected component. Let us consider the fields from left to right: El# 2 of 3 : This is component number 2 of 3 components (from the bottom) Fr: 0.17 to: 4.17 ft : This element spans from 0.17 ft to 4.17 ft from the datum line Up : Do not worry about this field for the time being Tr: 0.340 : This is the computed thickness for the internal pressure (120 psi) Mawp: 206.8 : This is the MAWP for this element (206.8 psi) MAPnc: 275.6 : Maximum allowable pressure new and cold (275.6 psi) Trext: 0.327 : The computed thickness for the external pressure Slen: 23.9 ft : The maximum unsupported length for the external pressure Let us now see what happens when there is a problem with an element. Go to the ‘Finished Thickness’ field, and change the thickness from 0.5 inches to 0.31 inches. Now look at the status bar at the bottom of the screen. It now looks like this: The required thickness for the internal and external pressures now appears in red, indicating that there is a problem. In our case, the problem is the thickness. It is not adequate. Change the thickness back to ‘0.5’ inches, to render the status bar values in black lettering.
  • 10. PVElite 2005 version Quick Start Page 10 of 24 The Output Processor Now we have built our simple model, we need to get the complete details of the calculations performed by PVElite. At the top of the screen there is a button that looks like this: Click this button. We now get the ‘Output Processor’ as follows: Your screen may look different, but it can easily be changed to look like the illustration above. The left window has the heading ‘Report List’. In the right window, we are told ‘There are no Reports Selected for Viewing’. In the left hand window, click on ‘Internal Pressure Calculations’ The right hand window now shows the results of the item you selected in the left hand window. The output window now looks as shown below:
  • 11. PVElite 2005 version Quick Start Page 11 of 24 You can scroll up and down to look at the complete calculation for the internal pressure computations. Generating and Printing the final pressure vessel report The illustration above shows the output only for the ‘Internal Pressure Calculations’. How do we get all the information? To select the items you want included in your final report do the following: Hold down the <Control> button on your keyboard, and while holding it down, click on the items you want included in the ‘Report List’ (left) window. Your selected items will be highlighted with a blue background like this (for example):
  • 12. PVElite 2005 version Quick Start Page 12 of 24 Once these items are selected, you are ready to generate the report. If you simply want to send the output to a printer, then you need only click this button (the print to printer button): This will print the report immediately with page numbers and headings on each page. There are other options. For example, you may find it convenient to send the output to MS- TM TM Word . Provided you have MS-Word installed on your computer, this is a simple process. This time, click this button: TM This will send the selected output result to MS-Word . This feature allows you, the user to edit the results, and add your own notes. You can also send the output to a text file. This time, from the file menu at the top of the screen, select ‘Print to file’: You will be asked for a file name. This will be a text file with a filename extension of .txt. You will TM TM be able to access this file with any text editor such as Notepad , or MS-Word . When you send the output to a text file, all the colored text will be lost, and will simply be in black type.
  • 13. PVElite 2005 version Quick Start Page 13 of 24 Data Input – Other information If you look at the bottom of the Data Input screen, you will see a series of tabs that look like this: If you look carefully at these tabs, you will see that the left most tab is currently selected. The full name of this tab is: ‘General Input’. This tab refers to the the basic dimensional, pressure, temperature and material section for the currently selected element. Let us now look at the other tabs: If we now click the ‘Heading’ tab we get the following screen: We have entered form information to demonstrate what can be typed in the first three fields (Lines 1,2 and 3). In the final output, whether sent to the printer, or to MS-WordTM, the three lines will appear at the top of each and every page of the report like this:
  • 14. PVElite 2005 version Quick Start Page 14 of 24 There is another field also while we have the ‘Heading’ tab selected. This is this one: Click the little button to the right (see the arrow in the above illustration) to have this screen open up: Design Constraints (Global Settings in PVElite) Enter any information you care to, and it will be printed on the Title Page when sent to the printer or to a file. This will over write the information PVElite would otherwise print as its default. If in th output processor you select the title page, it will now look like this: Let us now investigat the the ‘Design Constraints Tab’. It is this one:
  • 15. PVElite 2005 version Quick Start Page 15 of 24 This tab allows us to set the default values for the entire vessel. Let us look at some of the main fields: By entering the pressures and temperatures in these first four fields, PVElite will use these values as the default values for the whole vessel. This saves time later. The datum field. If you look at your 3D model on the screen it will look something likd this: PVElite has located the datum line at the tangent line of the bottom head. We can change the location of the datum line at anytime to move it to a more convenient location to suit your purpose. Let us do this now to see what happens: Set the datum line to 3 feet up from its current location: The model now looks like this: Once you have a skirt attached to the bottom of the vessel you may wish to mover the datum line to the bottom of the skirt as it may be more convenient. Hydrotest Type and Position of the hydrotest: From the drop down box, you can tell PVElite how it must calculate the hydrotest pressure
  • 16. PVElite 2005 version Quick Start Page 16 of 24 The next box also allows you to let PVElite know which position the vessel will be ini during the hydrotest: These are the choices you have available to you: Tall towers for example, are usually hydrotested in the horizontal position. PVElite has to compute the hydrostatic pressure from the water in the vessel at hydrotest time. If the vessel is tested in the vertical position, the pressure at the bottom of the vessel will be greater than if the vessel is tested in the horizontal position. Give careful consideration to the position that is appropriate to your situation. Nozzle Projections: Enter the nozzle projection from the surface of the vessel pressure envelope. This information is used by PVElite to compute any extra liquid level where the nozzle project higher than the vessel envelope. This information is fairly straight forward, and needs no further explanation. Minimum Metal Temperature: Enter the minimum metal temperature. This temperature will be applied to the whole vessel. In the case of carbon steel vessels, this temperature is very important. Where vessels are operating at low temperature, the material and weldments may need to be impact tested (UG-34 and UCS 66 of ASME Division 1). Also, using normalized materials may enhance the low temperature properties of the materials of construction. PVElite computes the minimum allowable metal temperature, and compares it with the required minimum metal temperature. Flange Distance to Top: Enter the distance from the centerline/face of flange to the top of the vessel. This value will be used in case the flanges govern the MAP of the vessel. If the vessel is being in the vertical position and the vessel is being tested in accordance with UG-99 c, this value will used in conjunction with the flange projection from top to determine the total static head to subtract for the type hydrostatic test.
  • 17. PVElite 2005 version Quick Start Page 17 of 24 Construction Type: The meanings are fairly obvious. It is most likely that the default ‘Welded’ is used about 99.9 % of the time. That is why it is the default setting. Service Type: The type of service is specific to ASME Section VIII, Division 1. The code (Section UW) imposes special requirements for vessels in lethal and steam services. This is usually left at the default value of ‘None’ Degree of Radiography: From the drop down box, click on the appropriate degree of radiography. PVElite does NOT automatically set the joint factor (E) from this global selection. Design Code: PVEite allows the user to perform vessel calculations in several pressure vessel codes. The following design codes are supported by PVElite: • ASME Section VIII, Division 1 • ASME Section VIII, Division 2 • The British PD 5500 • The European EN 13445
  • 18. PVElite 2005 version Quick Start Page 18 of 24 Once a code is selected, the user will have to re-select the materials, as each code has its own design stress tables. User Defined MAWP: The ASME Section VIII, Division 1 code determes the Maximim Allowable Working Pressure (MAWP) the vessel is able to sustain. PVElite uses the MAWP to compute the shop hydrotest pressure and the required reinforcement for nozzle reinforcement. The code (Division 1) allows the designer to set the MAWP to the design pressure. If you want the MAWP to be limited to a paraticular value, then PVElite will use this value instead of the computed MAWP in its computations. It is possible that the MAWP will exceed the allowable pressure rating of the vessel flanges. The computed MAWP could for example force the design to increase the flanges (for example) from Class 150 to Class 300, which could be expensive. User Defined MAPnc: In the cold condition, the flange ratings again could be exceeded. The user can set his own value of Maximum Allowable Pressure New and Cold. User Defined Hydro. Pressure: In the case of ASME Division 1, the hydrotest pressure is computed per UG-99 with varying degrees of severity. The user can reduce or change the hydrotest pressure. PVElite computes the actual stresses existing in the various components during the shop hydrotest. The stresses can be reduced by the user by setting the test pressure to a lower value. Aditional Operating Static Pressure: If for example, the vessel had a piping system attached, the liquid contained in the piping could add to the design pressure. If there are other factors that raise the pressure during the operating condition, this added pressure can be catered for. Use Higher Longitudinal Stress: The ASME Code (Section VIII, Division 1, Paragraph UG-23(d)) allows the allowable stress for the combination of earthquake loading, or wind loading with other loadings to be increased by a factor of 1.2. if the operating condition is below the following temperatures. To take advantage of this concession, check the box as shown above. Seismic and wind loads are considered to be occasion, whereas pressure loading is considered to be sustained.
  • 19. PVElite 2005 version Quick Start Page 19 of 24 Hydrotest, Allow Unmodified: By default PVElite uses the hydrotest stress times the allowable stress increase factor for occasional loads (times the joint efficiency. on the tensile side). However, for stainless steel vessels this value is often limited to 0.9 times the yield stress. Then this field should checked in order to use the defined value without any modification. Consider Vortex Shedding: If this box is checked PVElite will perform vortex shedding calculations on the vessel. This method is documented in the National Building Code of Canada and in texts on wind engineering. If are analyzing a tall slender vessel it may be susceptible to vortex shedding. PVElite will compute the likelihood of this occurrence based on the research of Zorilla and Mahajan. If there is no possibility of wind vibration and you have this box checked, PVElite will warn you that unrealistic (high) stresses will result and give you the option to turn this calculation off at run time. Is this a Heat Exchanger: Note: This check box is optional. If the Dimensional Solutions 3D file interface button is checked see above right), PVElite will write out a text file that contains the geometry and loading information for this particular vessel design. If this box is checked, the program will simply write this data out to the Jobname.ini file created in the current working directory. More information about the Dimensional Solutions product line can be found on their website at the following web site: www.Dimsoln.com To completely define an exchanger it is necessary to enter in the required information regarding the tubes, tubesheets and the floating head (if any). With the exchanger data, PVElite can then compute the weights and required thicknesses of the exchanger components Corroded Hydrotest: By default PVElite uses the uncorroded wall thickness when the stresses on the elements during the hydrotest are computed. In some cases it is necessary to hydrotest the vessel after it has corroded. If you wish to use a corroded thickness in the calculations, check this box. Please note that longitudinal stresses due to Hydrostatic test pressure will also be computed in a similar manner.
  • 20. PVElite 2005 version Quick Start Page 20 of 24 Hydrotest Allowable 90% Yield: For ASME Division 1, the hydrotest allowable stress is 1.3 times the ambient allowable stress for the material. When the vessel is tested, the largest circumferential stress should not exceed this value. If you wish to use 90 percent of the ambient yield stress instead of 1.3 the ambient allowable, then you can check this box. ASME Steel Stack: PVElite will analyze steel stacks in accordance with ASME STS-2000. A further discussion is outside the scope of this Quick Sart document. Let PVElite automatically select thickness / Stiffening Rings etc.: If any of the items is set to yes, PVElite will correct the item should it fail in the analysis. For example, if ‘Select Wall Thickness for Internal Pressure’ be set to ‘Yes’, PVElite will automatically increase the thickness of a component should it not be thick enough. By now, you should be able to figure out what the rest of the tabs at the bottom of the data input screen do. A little experimentation will make their use quite cliear. Building a Horizontal Vessel – Start a new vessel As discussed above, the vessel is built either from bottom to top, or from left to right. Let us quickly build a simple horizontal vessel: On the input data screen start with the first head. Simply click on this button : The head will look like this: Clearly, PVElite has assumed you are building a vertical vessel, and this is the bottom head. We need to Flip this head to enable us to build a horizontal vessel To do this, locate the ‘Flip’ button which looks like this: Click on this button, and the head will then be turn clockwise through 90 degress to look like this:
  • 21. PVElite 2005 version Quick Start Page 21 of 24 Now add the cylindrical shell and right hand head (as shown in the beginning of this document), until the vessel looks like this: The rest of the design is can be completed from here. Inserting a Component As discussed above, a vessel is built from the bottom to the top, or from left to right. Often a component is missing, and has to be inserted into the model. The procedure is very simple. These are the steps you must take: • Select the item on your model (click on the component in the 2D model is easiest). The selected component will turn light green. • Near the top of the screen click on the insert button: • A new screen opens up: • In the upper frame select the type of element you wish to insert
  • 22. PVElite 2005 version Quick Start Page 22 of 24 • In the lower frame, determine if you want the inserted element to inserted before (below or to the left) or after (above or to the right) of the formerly selected element. • If you experiment, it will all become quite cliear. Deleting a Component The steps are very simple: • Select the item you wish to delete (make sure there are no nozzles in this element). The selected element will turn light green in the 2D model. • Click the delete button: • Then follow the on screen instructions. What is meant by Node Numbers This is a very important topic. All elements that make up a vessel exist between nodes. At the top of the input screen you will see a box that looks lke this: Every main element (not attachments such as nozzles etc) has two nodes. Consider these two vessels shown below: Notice that every element from the bottom to the top, or from the left to the right exists between two node numbers. There is a ‘From Node’, and there is a ‘To Node’. In the case of the bottom (or left) head the nodes are situated at the tangent line and the weld line. The PVElite Help System PVElite has an extensive on screen help system. Let us once your cursor is sitting in a particular field, and you want information about that field. You can press the ‘F1’ key on your keyboard, and instant help is availlable. Also, the complete user manual is available at any time you need it. To ger the on screen user manual, click on ‘Help’ in the menu line, and select ‘View Documentation’
  • 23. PVElite 2005 version Quick Start Page 23 of 24 Conclusion This brings us to the end of our Quick Start discussion. If you work you way through this document, you will be able to build just about any type of vessel you please.