SlideShare une entreprise Scribd logo
1  sur  17
SCP Turbine Flame Detectors (UV) OmniGuard Model 660 Operation & Maintenance Prepared by :- Mustafa Ali Reviewed by :- Nabeel Minhaj / Khalil Sultan I & C Department (Sawan)
Description Omni Guard 660 Flame Detectors The Omniguard® 660 Series Flame Detectors are optically based, self-contained, microprocessor controlled, high-speed ultraviolet (UV) flame detectors.  These Flame Detectors are compatible with most alarm panels without the need for a controller. All electronics are housed within a copper free aluminum, high temperature, TGIC-Polyester coated enclosure with a 3/4-14NPT or M20-1.5 conduit entry. Operation Flame Detectors are single spectrum detectors utilizing the ultraviolet sensor tube. Flame Detector requires only that a signal, with in the detection envelope of the UV sensor, be present in a  pre-defined strength for a specified time duration. These parameters are user adjustable and will determine the sensitivity and response time to all fires. Applications Flame Detectors are designed for fire detection applications where sudden fires from hydrocarbon fuels or when proper options are selected, from specified non-hydrocarbon fuels, may occur.  These detectors are not recommended for smoldering, or electrical fire hazards.
Standard Features Microprocessor Based. 0 to 60 seconds user adjustable time delays. User adjustable latching or non-latching fire relays. User adjustable sensitivity. User adjustable NO or NC relay outputs. LED indication: fire (red), fault (amber). Transient voltage (surge) protection. Specifications ( Environmental ) Suitable for use in hazardous locations: Class I, Division 1, Groups B, C & D Class II, Division 1, Groups E, F & G NEMA 4 rated. Electrical Interface Nominal voltage input —24VDC(20 Min/32 Max). Maximum allowable ripple voltage — 240mV Current Draw (@ 24 VDC): Manual Auto Standby Alarm Test Relay Contact rating (660 High Temperature Model) 4 Amps @ 30 VDC (Resistive) Note:  Each detector contains two relays: (1) Fire, (1) Fault.
Typical Hydrocarbon Fire Spectrum
Flame Detector Horizontal Field of View
SCP Gas Turbine Enclosure Flame Detection Application ,[object Object],[object Object],[object Object],[object Object],[object Object],Tyco Panel Installed in UCP for Turbine enclosure F&G System Monitoring Two Flame Detectors with Tyco  Zone Module ( K1261 ) installed with  Normal / Fault / Test selectable options.
The General Monitors TL105 UV Test Lamp is a portable, rechargeable source of ultraviolet radiation, specifically designed for use in testing UV flame detectors. It emits a wide band of radiation, which includes the 185 to 260 nanometer region. To avoid damaging exposure to ultraviolet radiation, the TL105 provides a "Power On" indicator so that direct viewing of the lamp is not necessary.  The TL100 is approved by CSA as intrinsically safe for use in Class I, Division 1, Groups C & D. Fire Detector Testing ( Simulation )
Maintenance & Troubleshooting Periodic cleaning of the optical surfaces inessential,  The detectors should be regularly inspected for a build-up of dust or other contaminants on the optical surfaces. The detection specifications presented in this manual are predicated on performance with clean sensor windows. Contaminants such as dust, oil and paint will reduce sensitivity. Severe contamination on the light guides or sensor windows will cause a failure of the auto-test. A detector that fails auto-test due to dirty optical surfaces may be capable of detecting fire, but its effectiveness will be limited. Normal  Condition Flame Detectors are equipped with a fault relay to annunciate a change in the operational status of the detector. When power is applied to the detector, the fault relay will energize within 2 seconds. A loss of power will cause the relay to de-energize. If the fault relay output fails to change state within 2 seconds after power-up and the amber LED fails to illuminate. There may be no power reaching the detector’s electronic module. Check the supply voltage, the condition of the fuse located at F1 on the PCB and the wiring to terminals 8 and 10. Also, inspect the wiring to the fault relay terminals 6 and 7 and the jumper JP1 that sets the fault relay option.
Fault Condition Flame Detectors are equipped with automatic self-test in addition to the manual test. Approximately every 15 minutes, the automatic self-test is actuated and for a brief time interval, the optics and electronics are checked for functionality. If a detector goes into a fault condition, the optical surfaces should be checked for cleanliness. Clean sensor windows and light guide ends are necessary for the detector (s) to pass self-test. After the optical surfaces have been inspected and cleaned, reset the detector. If the detector is wired for manual test, perform the manual test. The typical response time should be from 0.6 seconds beyond the actual fire output time delay. Optical Self-Test Fire Detectors have a “through-the-lens” optical clarity-checking feature. The factory setting is for automatic test only, switch position 1 is “OFF”, and switch position 2 is “ON”.  If the addition of the manual test feature is desired, then toggle the switch position 1 to “ON”.  If only the manual test feature is needed, then toggle the switch position 1 “ON” and switch position 2 “OFF”. If no optical testing is preferred, then ensure that both of these switches are “OFF”.
Failure To Alarm Upon detection of fire, the fire outputs will activate and the red LED, visible through the UV sensor window, will turn “ON”. If during testing, a detector fails to alarm, inspect the sensor windows for cleanliness. Clean sensor windows are essential for effective optical fire detection. Should the detector continue to be inoperative, check the supply voltage and all associated wiring. Alarm Condition - No Fire Present A detector in alarm condition when no fire is present may be caused by an inadvertent actuation of the manual test.  Verify the light guides are illuminated. If they are, then check the manual test wiring and the test switch for broken, loose, or intermittent connections. Repair or tighten any faulty connections. If the light guides are not illuminated, then contact Omni Guard. Detection Speed Flame Detectors Switch position 5 is used to select two detection speeds. The normal speed utilizes a slower sampling rate and automatic self-test interval. The high speed setting increases the data sampling rate and auto self-test frequency.  The normal speed option is the factory setting and recommended for most applications.
Fire Time Delay Flame Detector The fire outputs can be configured to delay for up to 63 seconds. The factory setting for this delay time is 3 seconds.  To adjust the fire outputs delay time, use Potentiometer (Pot) R49. Turning the Pot counter clock wise (CCW) will decrease the time delay. One turn equals approximately five seconds. Sensitivity Levels Flame Detector Switch positions 3 and 4 adjust the sensitivity to four different levels.  Level 1 being the most sensitive to UV radiation and the most susceptible to false alarms. Level 2 is the factory setting and is recommended for most applications.
Relay Adjustments There are two relays, and Configuration Option Jumpers, JP1 and JP2, located on the exposed surface of the printed circuit board (PCB) in the housing assembly. Using these jumpers, the relays may be configured as normally open or closed. The factory will ship the detectors with the following settings. 1.) Fire relay (K2) — normally open: -will close when there is a fire present beyond the fire time delay setting. -will close when manual test is activated beyond the length of time for the fire delay time setting. Note:  The red, light emitting diode (LED), will be illuminated when relay transfers. 2.) Fault relay (K1) - normally open: - will close when power is applied (Model 860 after 2 seconds and Model 660 less then a second). - will open when power is lost (or fuse F1 on process PCB is open). - will open when detector fails automatic test. - will open when detector fails manual test. Note:  The amber LED will be illuminated when relay transfers, unless there is a loss of power. Caution: Upon applying power, insure that the detector remains on for at least 5 seconds to allow for complete initialization to take place.
User Selectable Options Locations
Terminal Wiring Identification
User Selectable DIP Switch Details
Siemens wiring Details
Tyco F&G Wiring Details

Contenu connexe

Tendances

Apostila festo pneumatica
Apostila festo pneumaticaApostila festo pneumatica
Apostila festo pneumaticaoantu
 
Chromatography Basics 2021
Chromatography Basics 2021Chromatography Basics 2021
Chromatography Basics 2021Yokogawa1
 
Clp [automação residencial com clp]
Clp [automação residencial com clp]Clp [automação residencial com clp]
Clp [automação residencial com clp]Josemar Pereira
 
Instrumentação 1 simbologia
Instrumentação 1 simbologiaInstrumentação 1 simbologia
Instrumentação 1 simbologiainstitutocarvalho
 
Topic 1 review of biomedical instrumentation
Topic 1 review of  biomedical instrumentationTopic 1 review of  biomedical instrumentation
Topic 1 review of biomedical instrumentationGhansyam Rathod
 
DCS fundamentals
DCS fundamentalsDCS fundamentals
DCS fundamentalsAlok Saikia
 
Interesting and Useful Features of the DeltaV PID Controller
Interesting and Useful Features of the DeltaV PID ControllerInteresting and Useful Features of the DeltaV PID Controller
Interesting and Useful Features of the DeltaV PID ControllerJim Cahill
 
Temperature sensor
Temperature sensorTemperature sensor
Temperature sensorRaj Kumar
 
04 acoes de_controle_em_malha_fechada_teoria_isa_curitiba
04 acoes de_controle_em_malha_fechada_teoria_isa_curitiba04 acoes de_controle_em_malha_fechada_teoria_isa_curitiba
04 acoes de_controle_em_malha_fechada_teoria_isa_curitibaJeferson Carmo
 
Process Analyzer Sampling Systems Simplified
Process Analyzer Sampling Systems SimplifiedProcess Analyzer Sampling Systems Simplified
Process Analyzer Sampling Systems SimplifiedYokogawa1
 
Apostila de instrumentação_industrial_-_senai
Apostila de instrumentação_industrial_-_senaiApostila de instrumentação_industrial_-_senai
Apostila de instrumentação_industrial_-_senaijeff1989
 
Yokogawa's GC8000 Process Analyzer Product Introduction
Yokogawa's GC8000 Process Analyzer Product IntroductionYokogawa's GC8000 Process Analyzer Product Introduction
Yokogawa's GC8000 Process Analyzer Product IntroductionYokogawa1
 

Tendances (20)

Apostila festo pneumatica
Apostila festo pneumaticaApostila festo pneumatica
Apostila festo pneumatica
 
Vibration sensor
Vibration sensorVibration sensor
Vibration sensor
 
Chromatography Basics 2021
Chromatography Basics 2021Chromatography Basics 2021
Chromatography Basics 2021
 
Clp [automação residencial com clp]
Clp [automação residencial com clp]Clp [automação residencial com clp]
Clp [automação residencial com clp]
 
Instrumentação 1 simbologia
Instrumentação 1 simbologiaInstrumentação 1 simbologia
Instrumentação 1 simbologia
 
Topic 1 review of biomedical instrumentation
Topic 1 review of  biomedical instrumentationTopic 1 review of  biomedical instrumentation
Topic 1 review of biomedical instrumentation
 
3 sensores-e-atuadores
3 sensores-e-atuadores3 sensores-e-atuadores
3 sensores-e-atuadores
 
DCS fundamentals
DCS fundamentalsDCS fundamentals
DCS fundamentals
 
Alarm management at DeltaV
Alarm management at DeltaVAlarm management at DeltaV
Alarm management at DeltaV
 
ii unit
 ii unit ii unit
ii unit
 
Interesting and Useful Features of the DeltaV PID Controller
Interesting and Useful Features of the DeltaV PID ControllerInteresting and Useful Features of the DeltaV PID Controller
Interesting and Useful Features of the DeltaV PID Controller
 
Temperature sensor
Temperature sensorTemperature sensor
Temperature sensor
 
04 acoes de_controle_em_malha_fechada_teoria_isa_curitiba
04 acoes de_controle_em_malha_fechada_teoria_isa_curitiba04 acoes de_controle_em_malha_fechada_teoria_isa_curitiba
04 acoes de_controle_em_malha_fechada_teoria_isa_curitiba
 
Seminar ppt
Seminar pptSeminar ppt
Seminar ppt
 
Modern control system
Modern control systemModern control system
Modern control system
 
Process Analyzer Sampling Systems Simplified
Process Analyzer Sampling Systems SimplifiedProcess Analyzer Sampling Systems Simplified
Process Analyzer Sampling Systems Simplified
 
Apostila de instrumentação_industrial_-_senai
Apostila de instrumentação_industrial_-_senaiApostila de instrumentação_industrial_-_senai
Apostila de instrumentação_industrial_-_senai
 
Yokogawa's GC8000 Process Analyzer Product Introduction
Yokogawa's GC8000 Process Analyzer Product IntroductionYokogawa's GC8000 Process Analyzer Product Introduction
Yokogawa's GC8000 Process Analyzer Product Introduction
 
Oxygen Analyzer
Oxygen AnalyzerOxygen Analyzer
Oxygen Analyzer
 
Pid controller
Pid controllerPid controller
Pid controller
 

Similaire à Omni Guard 660 Flame Detector Presentation

General Monitors Flame Detectors Scp
General Monitors Flame Detectors ScpGeneral Monitors Flame Detectors Scp
General Monitors Flame Detectors ScpMustafa Ali
 
Manual de instalacion detector honeywell
Manual de instalacion detector honeywellManual de instalacion detector honeywell
Manual de instalacion detector honeywellCésar Ortiz Rincón
 
Heiman hm 710 gas detector user manual - arab fires
Heiman hm 710 gas detector user manual - arab firesHeiman hm 710 gas detector user manual - arab fires
Heiman hm 710 gas detector user manual - arab firesarabfires
 
Flame Scanners Optimization
Flame Scanners OptimizationFlame Scanners Optimization
Flame Scanners OptimizationMustafa Ali
 
Andel Floodline - Instruction Manual
Andel Floodline - Instruction ManualAndel Floodline - Instruction Manual
Andel Floodline - Instruction ManualThorne & Derrick UK
 
3003 explosion proof fire sensor
3003 explosion proof fire sensor3003 explosion proof fire sensor
3003 explosion proof fire sensorkhuranasac
 
Electronic units and systems for armored vehicles
Electronic units and systems for armored vehiclesElectronic units and systems for armored vehicles
Electronic units and systems for armored vehiclesAndrew Diakoniuk
 
Building Electronics (Fire Detection and Alarm System and CCTV)
Building Electronics (Fire Detection and Alarm System and CCTV)Building Electronics (Fire Detection and Alarm System and CCTV)
Building Electronics (Fire Detection and Alarm System and CCTV)Jed Concepcion
 
Everspring sp816 user manual
Everspring sp816 user manualEverspring sp816 user manual
Everspring sp816 user manualDomotica daVinci
 
Fire and Gas Detection System : Part 1_The Field Devices and Its Panels
Fire and Gas Detection System : Part 1_The Field Devices and Its PanelsFire and Gas Detection System : Part 1_The Field Devices and Its Panels
Fire and Gas Detection System : Part 1_The Field Devices and Its PanelsGan Chun Chet
 
Edwards Signaling E-HD Data Sheet
Edwards Signaling E-HD Data SheetEdwards Signaling E-HD Data Sheet
Edwards Signaling E-HD Data SheetJMAC Supply
 
Edwards Signaling RB4U Data Sheet
Edwards Signaling RB4U Data SheetEdwards Signaling RB4U Data Sheet
Edwards Signaling RB4U Data SheetJMAC Supply
 
Edwards Signaling E-PD Installation Manual
Edwards Signaling E-PD Installation ManualEdwards Signaling E-PD Installation Manual
Edwards Signaling E-PD Installation ManualJMAC Supply
 
Smoke Alarm using Photodiode
Smoke Alarm using PhotodiodeSmoke Alarm using Photodiode
Smoke Alarm using PhotodiodeChintan Patel
 
General Monitors Gdi Presentation
General Monitors Gdi PresentationGeneral Monitors Gdi Presentation
General Monitors Gdi PresentationMustafa Ali
 

Similaire à Omni Guard 660 Flame Detector Presentation (20)

General Monitors Flame Detectors Scp
General Monitors Flame Detectors ScpGeneral Monitors Flame Detectors Scp
General Monitors Flame Detectors Scp
 
Manual de instalacion detector honeywell
Manual de instalacion detector honeywellManual de instalacion detector honeywell
Manual de instalacion detector honeywell
 
Heiman hm 710 gas detector user manual - arab fires
Heiman hm 710 gas detector user manual - arab firesHeiman hm 710 gas detector user manual - arab fires
Heiman hm 710 gas detector user manual - arab fires
 
Flame Scanners Optimization
Flame Scanners OptimizationFlame Scanners Optimization
Flame Scanners Optimization
 
Andel Floodline - Instruction Manual
Andel Floodline - Instruction ManualAndel Floodline - Instruction Manual
Andel Floodline - Instruction Manual
 
3003 explosion proof fire sensor
3003 explosion proof fire sensor3003 explosion proof fire sensor
3003 explosion proof fire sensor
 
Six channel fire monitoring & control
Six channel fire monitoring & controlSix channel fire monitoring & control
Six channel fire monitoring & control
 
Smoke Detection System
Smoke Detection SystemSmoke Detection System
Smoke Detection System
 
Flame Scanner.ppt
Flame Scanner.pptFlame Scanner.ppt
Flame Scanner.ppt
 
Electronic units and systems for armored vehicles
Electronic units and systems for armored vehiclesElectronic units and systems for armored vehicles
Electronic units and systems for armored vehicles
 
Building Electronics (Fire Detection and Alarm System and CCTV)
Building Electronics (Fire Detection and Alarm System and CCTV)Building Electronics (Fire Detection and Alarm System and CCTV)
Building Electronics (Fire Detection and Alarm System and CCTV)
 
Everspring sp816 user manual
Everspring sp816 user manualEverspring sp816 user manual
Everspring sp816 user manual
 
Fire and Gas Detection System : Part 1_The Field Devices and Its Panels
Fire and Gas Detection System : Part 1_The Field Devices and Its PanelsFire and Gas Detection System : Part 1_The Field Devices and Its Panels
Fire and Gas Detection System : Part 1_The Field Devices and Its Panels
 
Eclipse manual
Eclipse manualEclipse manual
Eclipse manual
 
Edwards Signaling E-HD Data Sheet
Edwards Signaling E-HD Data SheetEdwards Signaling E-HD Data Sheet
Edwards Signaling E-HD Data Sheet
 
Edwards Signaling RB4U Data Sheet
Edwards Signaling RB4U Data SheetEdwards Signaling RB4U Data Sheet
Edwards Signaling RB4U Data Sheet
 
Edwards Signaling E-PD Installation Manual
Edwards Signaling E-PD Installation ManualEdwards Signaling E-PD Installation Manual
Edwards Signaling E-PD Installation Manual
 
Smoke Alarm using Photodiode
Smoke Alarm using PhotodiodeSmoke Alarm using Photodiode
Smoke Alarm using Photodiode
 
General Monitors Gdi Presentation
General Monitors Gdi PresentationGeneral Monitors Gdi Presentation
General Monitors Gdi Presentation
 
Banner sensors fiber
Banner sensors fiberBanner sensors fiber
Banner sensors fiber
 

Omni Guard 660 Flame Detector Presentation

  • 1. SCP Turbine Flame Detectors (UV) OmniGuard Model 660 Operation & Maintenance Prepared by :- Mustafa Ali Reviewed by :- Nabeel Minhaj / Khalil Sultan I & C Department (Sawan)
  • 2. Description Omni Guard 660 Flame Detectors The Omniguard® 660 Series Flame Detectors are optically based, self-contained, microprocessor controlled, high-speed ultraviolet (UV) flame detectors. These Flame Detectors are compatible with most alarm panels without the need for a controller. All electronics are housed within a copper free aluminum, high temperature, TGIC-Polyester coated enclosure with a 3/4-14NPT or M20-1.5 conduit entry. Operation Flame Detectors are single spectrum detectors utilizing the ultraviolet sensor tube. Flame Detector requires only that a signal, with in the detection envelope of the UV sensor, be present in a pre-defined strength for a specified time duration. These parameters are user adjustable and will determine the sensitivity and response time to all fires. Applications Flame Detectors are designed for fire detection applications where sudden fires from hydrocarbon fuels or when proper options are selected, from specified non-hydrocarbon fuels, may occur. These detectors are not recommended for smoldering, or electrical fire hazards.
  • 3. Standard Features Microprocessor Based. 0 to 60 seconds user adjustable time delays. User adjustable latching or non-latching fire relays. User adjustable sensitivity. User adjustable NO or NC relay outputs. LED indication: fire (red), fault (amber). Transient voltage (surge) protection. Specifications ( Environmental ) Suitable for use in hazardous locations: Class I, Division 1, Groups B, C & D Class II, Division 1, Groups E, F & G NEMA 4 rated. Electrical Interface Nominal voltage input —24VDC(20 Min/32 Max). Maximum allowable ripple voltage — 240mV Current Draw (@ 24 VDC): Manual Auto Standby Alarm Test Relay Contact rating (660 High Temperature Model) 4 Amps @ 30 VDC (Resistive) Note: Each detector contains two relays: (1) Fire, (1) Fault.
  • 6.
  • 7. The General Monitors TL105 UV Test Lamp is a portable, rechargeable source of ultraviolet radiation, specifically designed for use in testing UV flame detectors. It emits a wide band of radiation, which includes the 185 to 260 nanometer region. To avoid damaging exposure to ultraviolet radiation, the TL105 provides a "Power On" indicator so that direct viewing of the lamp is not necessary. The TL100 is approved by CSA as intrinsically safe for use in Class I, Division 1, Groups C & D. Fire Detector Testing ( Simulation )
  • 8. Maintenance & Troubleshooting Periodic cleaning of the optical surfaces inessential, The detectors should be regularly inspected for a build-up of dust or other contaminants on the optical surfaces. The detection specifications presented in this manual are predicated on performance with clean sensor windows. Contaminants such as dust, oil and paint will reduce sensitivity. Severe contamination on the light guides or sensor windows will cause a failure of the auto-test. A detector that fails auto-test due to dirty optical surfaces may be capable of detecting fire, but its effectiveness will be limited. Normal Condition Flame Detectors are equipped with a fault relay to annunciate a change in the operational status of the detector. When power is applied to the detector, the fault relay will energize within 2 seconds. A loss of power will cause the relay to de-energize. If the fault relay output fails to change state within 2 seconds after power-up and the amber LED fails to illuminate. There may be no power reaching the detector’s electronic module. Check the supply voltage, the condition of the fuse located at F1 on the PCB and the wiring to terminals 8 and 10. Also, inspect the wiring to the fault relay terminals 6 and 7 and the jumper JP1 that sets the fault relay option.
  • 9. Fault Condition Flame Detectors are equipped with automatic self-test in addition to the manual test. Approximately every 15 minutes, the automatic self-test is actuated and for a brief time interval, the optics and electronics are checked for functionality. If a detector goes into a fault condition, the optical surfaces should be checked for cleanliness. Clean sensor windows and light guide ends are necessary for the detector (s) to pass self-test. After the optical surfaces have been inspected and cleaned, reset the detector. If the detector is wired for manual test, perform the manual test. The typical response time should be from 0.6 seconds beyond the actual fire output time delay. Optical Self-Test Fire Detectors have a “through-the-lens” optical clarity-checking feature. The factory setting is for automatic test only, switch position 1 is “OFF”, and switch position 2 is “ON”. If the addition of the manual test feature is desired, then toggle the switch position 1 to “ON”. If only the manual test feature is needed, then toggle the switch position 1 “ON” and switch position 2 “OFF”. If no optical testing is preferred, then ensure that both of these switches are “OFF”.
  • 10. Failure To Alarm Upon detection of fire, the fire outputs will activate and the red LED, visible through the UV sensor window, will turn “ON”. If during testing, a detector fails to alarm, inspect the sensor windows for cleanliness. Clean sensor windows are essential for effective optical fire detection. Should the detector continue to be inoperative, check the supply voltage and all associated wiring. Alarm Condition - No Fire Present A detector in alarm condition when no fire is present may be caused by an inadvertent actuation of the manual test. Verify the light guides are illuminated. If they are, then check the manual test wiring and the test switch for broken, loose, or intermittent connections. Repair or tighten any faulty connections. If the light guides are not illuminated, then contact Omni Guard. Detection Speed Flame Detectors Switch position 5 is used to select two detection speeds. The normal speed utilizes a slower sampling rate and automatic self-test interval. The high speed setting increases the data sampling rate and auto self-test frequency. The normal speed option is the factory setting and recommended for most applications.
  • 11. Fire Time Delay Flame Detector The fire outputs can be configured to delay for up to 63 seconds. The factory setting for this delay time is 3 seconds. To adjust the fire outputs delay time, use Potentiometer (Pot) R49. Turning the Pot counter clock wise (CCW) will decrease the time delay. One turn equals approximately five seconds. Sensitivity Levels Flame Detector Switch positions 3 and 4 adjust the sensitivity to four different levels. Level 1 being the most sensitive to UV radiation and the most susceptible to false alarms. Level 2 is the factory setting and is recommended for most applications.
  • 12. Relay Adjustments There are two relays, and Configuration Option Jumpers, JP1 and JP2, located on the exposed surface of the printed circuit board (PCB) in the housing assembly. Using these jumpers, the relays may be configured as normally open or closed. The factory will ship the detectors with the following settings. 1.) Fire relay (K2) — normally open: -will close when there is a fire present beyond the fire time delay setting. -will close when manual test is activated beyond the length of time for the fire delay time setting. Note: The red, light emitting diode (LED), will be illuminated when relay transfers. 2.) Fault relay (K1) - normally open: - will close when power is applied (Model 860 after 2 seconds and Model 660 less then a second). - will open when power is lost (or fuse F1 on process PCB is open). - will open when detector fails automatic test. - will open when detector fails manual test. Note: The amber LED will be illuminated when relay transfers, unless there is a loss of power. Caution: Upon applying power, insure that the detector remains on for at least 5 seconds to allow for complete initialization to take place.
  • 15. User Selectable DIP Switch Details
  • 17. Tyco F&G Wiring Details