This document is an oil analysis report from PT. Petrolab Services for a sample from PT. EKA SEJAHTERA ABADI. The report provides the results of tests on multiple parameters of the oil sample including viscosity, total base number, color, wear metals, additives, flash point, FTIR analysis, water content, and notes that the analysis results are normal with resampling recommended at 5,000 running hours.
1. Nama Pelanggan :
Alamat :
(Address)
Telepon/Faks :
(Phone/Fax)
Untuk Pelanggan : Jam Kerja Oil :
(Attention) (Running Hours of Oil)
Nama Sampel : :
(Sample Name)
No. Lab. : :
(Lab. No.)
Tgl. Pengambilan Sampel : :
(Sampling date)
Tgl. Penerimaan Sampel : :
(Received date)
Tgl. Analisis : :
(Analysis date)
No Unit
1 Appearance
2 Viscosity Kin at 100°C cSt ASTM D 445-09
3 Total Base Number (TBN) mg KOH/g ASTM D 2896-07a
4 Colour ASTM *)
No. ASTM ASTM D 1500
5 Wear Metal *)
Fe (Iron) *)
ppm
Cu (Copper) *)
ppm
Aluminium (Al) *)
ppm
Pb (Lead) *)
ppm
Cr (Chromium) *)
ppm
Ni (Nikel) *)
ppm
Sn (Tin) *)
ppm
Silicon (Si) *)
ppm
Na (Sodium) *)
ppm
6 Metal Additive : *)
Ca (Calcium) *)
ppm
Mg (Magnesium) *)
ppm
Zn (Zinc) *)
ppm
7 Flash Point COC °C ASTM D 92-05a
8 FTIR *)
Soot *)
Abs/0.1 mm
Oxidation *)
Abs/0.1 mm
Nitration *)
Abs/0.1 mm
Sulfation *)
Abs/0.1 mm
Fuel *)
%
Glycol *)
%
9 Water Content by Distillation %vol ASTM D 95-05
Manager Teknis,
Asbari, SSi
Catatan : Data analisa hanya berlaku untuk sampel yang diuji di Laboratorium PT. Petrolab Services RK/5.10/01/01/04
(Note) Pengaduan tidak dilayani setelah 30 hari dari tanggal report diterbitkan.
*)
Diluar ruang lingkup akreditasi
No. 05228/NEO/NO/09/12
Jakarta, 28 September 2012
PT. EKA SEJAHTERA ABADI Overall Analysis Result
(Customer Name)
Normal
Kencana Tower Lt.3 Komplek Perk Jl. Raya Meruya Utara - Kembangan,
Jakarta Barat
021 - 99650461 / 021 - 58901427
PT. SIBA SURYA SEMARANG 1.440
15345 KM
(Running Hours)
05261/L/12 Pembuat Mesin -
(Eng. Builder)
18 September 2012 Type Mesin -
(Eng. Type/ Model)
25 September 2012 No. Seri H 1956 LS, H 1809 BF
(5A)(Serial Number )
25 - 28 September 2012 Lokasi Mesin -
(Eng. Location)
PARAMETER Method RESULT Limit Used Oil. *
VISUAL (MU/5.4/01/04-APP) Dark -
13,97 11,25 - 17,93
6,78 Min. 4,40
N/D -
ASTM D 5185-09 18 Max. 125
ASTM D 5185-09 2 Max. 35
ASTM D 5185-09 1 max. 25
ASTM D 5185-09 < 1 max. 25
ASTM D 5185-09 < 1 Max. 15
ASTM D 5185-09 < 1 Max. 10
ASTM D 5185-09 < 1 Max. 20
ASTM D 5185-09 5 Max. 45
ASTM D 5185-09 < 1 Max. 50
232 -
-
0,24 Max. 0,4
ASTM E 2412-04 0,15 Max. 0,8
ASTM E 2412-04 0,13 Max. 0,4
PT PETROLAB Services
Komplek Ruko Graha Mas. Blok AD No.23 Rawamangun - Jakarta Timur 13220; Telp: +62 21 4717001; Fax: +62 21 4716985
petrolab@cbn.net.id; http://www.petrolab.co.id
ASTM E 2412-04 0,00 Max. 3
ASTM E 2412-04 0,00 Max. 3
N/D = Not Defined
-
< 0,05 Max. 0,2
Keterangan:
(Remarks) Hasil analisa normal. Resampling 5.000 km berikutnya.
ASTM E 2412-04 0,11 Max. 0,4
ASTM E 2412-04
ASTM D 5185-09 820 -
ASTM D 5185-09 2192 -
ASTM D 5185-09 8
OIL ANALYSIS REPORTLube and Fuel Laboratory Consultant
PT. Petrolab Services
OIL ANALYSIS REPORTOIL ANALYSIS REPORTOIL ANALYSIS REPORT
Page 1 of 1
PENLUBE CI-4 SAE 15W-40 Jam Kerja Mesin