Superior Duct Fabrication is pleased to now offer Owens Corning® QuietZone®
Spiral Duct Liner. It is both anti-bacterial and anti-fungal. QuietZone® Spiral Duct
Liner is available in 1", 1.5", and 2" thicknesses. It is tested according to UL 181
standards and is listed with UL Laboratories® The R-value and sound absorption
of QuietZone® Spiral Duct Liner outperforms other compressed insulation
available in the market.
Superior Duct Fabrication’s highly trained and experienced mechanics and sheet
metal workers use Superior’s special equipment and processes to assure that
every QuietZone® Spiral Duct Liner board is carefully grooved, cut to size and
fitted in spiral duct and fittings.The surface is fitted with a durable and permanent
airstream surface that is longer lasting, when compared to insulating products
with sprayed-on coatings that tend to get brittle and crack over time. Superior
Duct Fabrication round, internally-lined systems are the perfect, economical
solution..
QuietZone® Spiral Duct Liner
Key Features
• Outstanding thermal and acoustical performance
• Cleanable surface with a black mat facing that provides a
smooth, durable surface making it easier to clean the duct
liners using methods and equipment described in North
American Insulation Manufacturers Association (NAIMA)
Publication AH122, Cleaning Fibrous Glass
Insulated Duct Systems: Recommended Practice
• Bacterial and fungal growth resistant with an EPA registered
biocide that protects the airstream surface from microbial
growth Standards, Codes Compliance
• National Fire Protection Association Standards
NFPA 90A/90B
• ICC International Mechanical Code
• NYC MEA# 186-69
• Meets requirements of ASTM C1338, ASTM G21, fungi test)
and ASTM G22 (bacteria test)
• ASTM C1071, Type II Rigid
Superior Duct Fabrication is an independent contractor and not an affiliate of Owens Corning Insulating
Systems, LLC or its affiliated companies. The color PINK is a registered trademark of Owens Corning.
Quiet Zone.qxp_Layout 1 4/28/15 2:37 PM Page 1
2. On time Deliveries | High Quality | Efficiency | Integrity | Knowledge | Dedication to Excellence
Air Handling Insulation Solution
Superior Duct Fabrication | 1683 Mount Vernon Ave. | Pomona, Ca. 91768 | Hours: Monday - Friday 5:00am to 5:00pm
(800) 797-Duct (3828) Toll-Free | (909) 620-6374 Main Fax | www.sdfab.com
1. The surface burning characteristics of these products have been determined in accordance with UL 723. This standard should be used to
measure and describe the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions
and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions.
However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to
an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating. ASTM E84 and UL 723 are the same test
method.
Thermal Performance
at 75ºF (24ºC) Mean Temperature
Physical Property Data
1" (25mm) 1.5" (38mm) 2.0” (5lmm)
R-value: ft2•ºF/Btu (RSI: m2•ºC/W) 4.3 (0.76) 6.5 (1.15) 8.7 (1.53)
k-value: Btu•in/hr•ft2•ºF (W/m2•ºC) 0.23 (0.033) 0.23 (0.033) .23 (0.033)
Property Test Method Value
Maximum Temperature Limits UL 181
Internal 250°F (121ºC)
External 150°F (66ºC)
Maximum Air Velocity UL 181 Erosion Test 6,000 fpm (30.5 m/s)
Water Vapor Sorption (by weight) ASTM C1104 <3% at 120°F (49ºC), 95% R.H.
Mold Growth UL 181/ASTM C1338 Meets requirements
Fungi Resistance ASTM G21 Meets requirements
Bacteria Resistance ASTM G22 Meets requirements
Surface Burning Characteristics
Flame Spread
Smoke Developed
UL 7231
ASTM E84
25
50
Acoustical Performance - ASTM C 423
Thickness 125 250 500 1000 2000 4000 NRC
1.0” 0.08 0.19 0.69 0.94 0.99 0.98 0.70
1.5” 0.12 0.33 0.92 1.04 1.03 1.02 0.85
2.0” 0.14 0.72 1.15 1.12 1.06 1.07 1.00
Quiet Zone.qxp_Layout 1 4/28/15 2:37 PM Page 2