2. Before You Start – Network Bandwidth Check
Browser
SMR8300
Windows based PC
GbE Switch
VMS Remote Client
100Mbit network, check?
Cameras
Click!
The Network bandwidth will effect the quality.
Please guarantee the Network bandwidth first!
3. Before You Start – Network Bandwidth Check
Browser
SMR8300
Windows based PC
GbE Switch
VMS Remote Client
Cameras
GbE network, check?
Click!
The Network bandwidth will effect the quality.
Please guarantee the Network bandwidth first!
4. Before You Start – Network Bandwidth Check
Browser
Windows based PC
GbE Switch
VMS Remote Client GbE network, check?
Click!
SMR8300
The Network bandwidth will effect the quality.
Please guarantee the Network bandwidth first!
5. Before You Start – Network Bandwidth Check
Browser
Windows based PC
GbE Switch
VMS Remote Client
100Mbit network, check?
Cameras
Click!
SMR8300
The Network bandwidth will effect the quality.
Please guarantee the Network bandwidth first!
6. Before You Start – Installation Scenario
DHCP Server presented No DHCP Server
DHCP Server presented Case 1 Case 3
No DHCP Server Case 2 Case 4
Customer Field Site
Your Office / Lab
* The network bandwidth between camera and NVR is 100Mbit or higher.
* The network bandwidth between remote client and NVR(SMR) is 1Gbit or higher.
* The total power budget of your PoE switch is enough for all cameras.
* Please make sure you already check all the pre-condition and meet all requirements
Please click the scenario which is matched your case.
7. Case 1
DHCP Server presented No DHCP Server
DHCP Server presented Case 1 Case 3
No DHCP Server Case 2 Case 4
Customer Field Site
Your Office / Lab
You have DHCP server in LAB.
Your customer has DHCP server.
8. 8
Case 1 – SMR8300
: Your LAB
: Customer site
DHCP Server
Cameras
SMR8300
Your LAB
Installation Procedure:
1. No need to pre-configure in your LAB.
Notice:
1. It is highly recommended to setup the system directly at customer site.
2. If you have configured the cameras in your office, please remember to delete all cameras
in SMR8300 before you go to customer sites.
You have DHCP server in LAB.
9. 9
Case 1 – IP Camera
: Your LAB
: Customer site
DHCP Server
Cameras
Your LAB
Installation Procedure:
1. No need to pre-configure in your LAB.
You have DHCP server in LAB.
SMR8300
Notice:
1. It is highly recommended to setup the system directly at customer site.
2. Cameras will all get the IP automatically in your customer’s site.
10. 10
Case 1 – Field Site Installation
: Your LAB
: Customer site
DHCP Server
Cameras
Your Customer Site
Installation Procedure:
1. Bring all products to your customer site.
2. Install all cameras, and power on all cameras.
3. Attach the network cables to LAN1 on SMR8300
4. Set DHCP mode to SMR8300 in Installation Wizard.
5. Add cameras into SMR8300.
6. Done
Your customer has DHCP server.
Back to Index
SMR8300
Notice:
1. It is highly recommended to setup the system directly at customer site.
2. Remember to attach the cable to LAN1 on SMR8300.
3. Cameras will all get the IP automatically.
4. If you have configured the cameras in your office, please remember to delete all cameras
in SMR8300 before you go to customer sites.
11. Case 2
DHCP Server presented No DHCP Server
DHCP Server presented Case 1 Case 3
No DHCP Server Case 2 Case 4
Customer Field Site
Your Office / Lab
You DO NOT have DHCP server in LAB.
Your customer has DHCP server.
12. 12
Case 2 – SMR8300
: Your LAB
: Customer site
DHCP Server
Cameras
Your LAB
Installation Procedure:
1. No need to pre-configure in your LAB.
You DO NOT have DHCP server in LAB.
SMR8300
Notice:
1. It is highly recommended to setup the system directly at customer site.
2. If you have configured the cameras in your office, please remember to delete all cameras
in SMR8300 before you go to customer sites.
13. 13
Case 2 – IP Camera
: Your LAB
: Customer site
DHCP Server
Cameras
Your LAB
Installation Procedure:
1. No need to pre-configure in your LAB.
You DO NOT have DHCP server in LAB.
SMR8300
Notice:
1. It is highly recommended to setup the system directly at customer site.
2. Cameras will all get the IP automatically in your customer’s site.
14. 14
Case 2 – Field Site Installation
: Your LAB
: Customer site
Installation Procedure:
1. Bring all products to your customer site.
2. Install all cameras, and power on all cameras.
3. Attach the network cables to LAN1 on SMR8300
4. Set DHCP mode to SMR8300 in Installation Wizard.
5. Add cameras into SMR8300.
6. Done
Your customer has DHCP server.
Back to Index
DHCP Server
Cameras
Your Customer Site
SMR8300
Notice:
1. It is highly recommended to setup the system directly at customer site.
2. Remember to attach the cable to LAN1 on SMR8300.
3. Cameras will all get the IP automatically.
4. If you have configured the cameras in your office, please remember to delete all cameras
in SMR8300 before you go to customer sites.
15. Case - 3
DHCP Server presented No DHCP Server
DHCP Server presented Case 1 Case 3
No DHCP Server Case 2 Case 4
Customer Field Site
Your Office / Lab
You have DHCP server in LAB.
Your customer DO NOT have DHCP server.
16. 16
Case 3 – SMR8300
: Your LAB
: Customer site
DHCP Server
Cameras
Your LAB
Installation Procedure:
1. Get the field site IP list of all devices.
2. Attach the network cables to LAN1 on SMR8300.
3. Power on the SMR8300, run the Installation wizard.
4. Configure the IP of SMR8300 in the wizard according to field site IP list.
Notice:
1. Remember to attach the cable to LAN1 on SMR8300.
2. Please skip the “step8: Add Camera”, we will add camera later.
You have DHCP server in LAB.
SMR8300
17. 17
Case 3 – IP Camera
DHCP Server
Cameras
Your LAB
Installation Procedures:
1. Get the field site IP list of all devices.
2. Power on and connect all cameras to a PoE switch in your LAB.
3. The PoE switch should connect with you LAB network.
4. Use Surveon IP utility to find all cameras.(On Windows PC)
5. Login and change the IP of all cameras according to field site IP list.
6. Login SMR8300, and use the local client to add all cameras into SMR8300.
Notice:
1. Surveon IP Utility:
https://www.dropbox.com/s/acv2orn5rmpjmmn/IP%20Utility%20V1.3A05.Surveon.20141205.zip?dl=0
2. You need a windows-based PC, installed with IE10 or before.
You have DHCP server in LAB.
Windows PC + IP Utility
SMR8300
18. 18
Case 3 – Field Site Installation
: Your LAB
: Customer site
Cameras
NVR3000
Your Customer Site
Installation Procedure:
1. Bring all products to your customer site.
2. Install all cameras, and power on all cameras.
3. Done
Your customer DO NOT have DHCP server.
Back to Index
Notice:
1. If possible, please keep the network independent, and being used only for the NVR(SMR) and
cameras.
2. Make sure the network bandwidth of customer’s site is guarantee.
Private and Independent Network SMR8300
19. Case 4
DHCP Server presented No DHCP Server
DHCP Server presented Case 1 Case 3
No DHCP Server Case 2 Case 4
Customer Field Site
Your Office / Lab
You DO NOT have DHCP server in LAB.
Your customer DO NOT have DHCP server.
20. 20
Case 4 – SMR8300
: Your LAB
: Customer site
DHCP Server
Cameras
Your LAB
Installation Procedure:
1. Get the field site IP list of all devices.
2. Attach the network cables to LAN1 on SMR8300.
3. Power on the SMR8300, run the Installation wizard.
4. Configure the IP of SMR8300 in the wizard according to field site IP list.
Notice:
1. Remember to attach the cable to LAN1 on SMR8300.
2. Please skip the “step8: Add Camera”, we will add cameras later.
You DO NOT have DHCP server in LAB.
SMR8300
21. 21
Case 4 – IP Camera
Cameras
Your LAB
Installation Procedures:
1. Get the field site IP list of all devices.
2. Find a windows PC, and change its network configuration to 192.168.88.1/24
3. Connect and power on only one camera to switch.
4. Use the PC to login camera, the camera IP will be 192.168.88.10/24.
5. Change the IP address of cameras according to your field site IP list.
6. The camera will reboot.
7. Repeat 7~10 until all cameras get the correct IP.
8. Add cameras into SMR8300.
Notice:
1. Surveon IP Utility:
https://www.dropbox.com/s/acv2orn5rmpjmmn/IP%20Utility%20V1.3A05.Surveon.20141205.zip?dl=0
2. You need a windows-based PC, installed with IE10 or before.
Windows PC
You DO NOT have DHCP server in LAB. : Your LAB
: Customer site
SMR8300
22. 22
Case 4 – Field Site Installation
: Your LAB
: Customer site
Cameras
NVR3000
Your Customer SiteInstallation Procedure:
1. Bring all products to your customer site.
2. Install all cameras, and power on all cameras.
3. Done
Your customer DO NOT have DHCP server.
Back to Index
Notice:
1. If possible, please keep the network independent, and being used only for the NVR and cameras.
2. Make sure the network bandwidth of customer’s site is guarantee.
Private and Independent Network NVR3000
SMR8300