1. Tel: +44 (0)191 490 1547
Fax: +44 (0)191 477 5371
Email: northernsales@thorneandderrick.co.uk
Website: www.heattracing.co.uk
for long heating circuits
The heating cable ELW-3-FEP/PVC is particularly suited for specific applications requiring long heating
distances to be covered. The heating cable is applied for frost protection, typical application ranges
are for example pipes in tunnels.
The heating cable consists of three high-quality resistance wires with an insulation of chemically re-sistant
FEP. Additionally the heating cable is protected by a PVC outer jacket.
Moreover the heating cable stands out for simple installation in spite of its solid design.
Type ELW-3-FEP/PVC up to 90 °C
Advantages:
Long heating circuits
Simple termination
Different nominal voltages
Moisture proof
Easy to assemble thanks to
longitudinal lay
Applications:
Long distances
Frost protection and temperature maintenance
Pipes in tunnels
Fire mains
Heating tape
he aHteinagti ncagb claebs laen udn hde Haetiinzgb ätanpdesr 1.45
www.thorneanderrick.co.uk
2. 03/2012 – All rights reserved. Subject to change without notice.
Outer jacket
PVC
Type ELW-3-FEP/PVC
up to 90°C
For suitable connection and termination kits please note our considera-ble
accessories catalogue unit.
Heating conductor
Technical information
Data
Insulation fluoropolymer
Outer jacket PVC
Nominal voltage 300/500 V
Output, max. 25 W/m
Working temp., max. 90 °C power off
30 °C power on
Insulation thickness 1 mm
Bending radius 30 mm
Protection class II
Moisture proof yes
Insulation
fluoropolymer
Type Resistance
Ω/km
Circuit length*, min. in
m(400 V/Stern)
Dimensions, approx (mm) Item n°
3 x 0,50 mm2 34,2 435 5,2 x 17,1 03T0342
3 x 0.,75 mm2 23,8 520 5,2 x 17,1 03T0238
3 x 1,00 mm2 17,1 610 5,2 x 17,1 03T0171
3 x 1,50 mm2 11,5 750 5,2 x 17,1 03T0115
3 x 2,50 mm2 7,0 952 8,0 x 20,6 03T0070
3 x 4,00 mm2 4,3 1215 8,0 x 20,6 03T0043
3 x 6,00 mm2 2,9 1480 8,0 x 20,6 03T0029