The document describes the Shimadzu FTIR-8400S Fourier Transform Infrared Spectrophotometer. It maintains optimal interferometer alignment automatically through a dynamic alignment system, ensuring high quality and reproducible spectra. It also includes IRsolution software for easy analysis and compliance with FDA regulations. Key features include high signal-to-noise ratio, automatic validation of instrument performance, and data processing and analysis capabilities.
1. C103-E062B
FTIR-8400S
Fourier Transform Infrared Spectrophotometer
Shimadzu was the first company to offer dynamic alignment as a standard feature in an affordable FTIR
spectrometer. With state-of-the-art technology, the Shimadzu dynamic alignment system continuously
maintains optimal alignment during data acquisition, ensuring consistently reproducible spectra without
the need for tedious mechanical adjustments.
FTIR-8400S is combined with the IRsolution - a 32 bit high performance FTIR software - to analyze your
samples easily and securely.
T h e S i g n a l - t o - N o i s e A dva n t ag e T h e S i m p l i c i t y A dva n t ag e
Peak-to-Peak S/N ratio is 20,000:1 or better, New FTIR operators will love the quick-start
guaranteed! function that prompts the user through every
action from setting scan parameters and
The Dynamic Alignment Advantage acquiring the spectrum, to detecting peaks and
Optimal interferometer alignment is maintained printing.
automatically for continuous optimization and
exceptional reproducibility. T h e I R s o l u t i o n A dva n t ag e
Powerful IRsolution software offers a myriad of
T h e Va l i d a t i o n A dva n t ag e standard data processing functions.
The software validates instrument performance The management of user group, protection by
to ensure compliance based on user name/password, and operation log
Japanese/European Pharmacopoeia and ASTM. recording with IRsolution Agent software supports
The instrument and data reliability are ensured the FDA 21 CFR Part 11.
by GLP/GMP and FDA 21 CFR Part 11
compliance.
2. FTIR-8400S
Specifications Dimensions
Interferometer Michelson type with 30¡ incident angle, dynamic alignment, With desktop PC
sealed and desiccated
Optical system Single beam optics
Beam splitter Germanium-coated KBr plate 305
Light source High brightness ceramic
Detector Temperature controlled high sensitivity detector (DLATGS detector)
326
584
Greater than 20,000:1 (KRS-5 window, 4cm-1,
S/N ratio
1 minute, 2200cm-1, P-P)
Wavenumber range 7,800cm-1 - 350cm-1
Resolution 0.85, 1, 2, 4, 8, 16cm-1 622
460
Mirror speed 3 steps; 2.8, 5, 9mm/sec
Data sampling He-Ne laser
Sample compartment W200mm x D230mm x H170mm
Arithmetic operation between spectrum and constant,
Arithmetic operation among spectra, Spectral subtraction,
250
Data processing
Peak detection, Smoothing, Derivative, Baseline
functions
correction, Data correction, Normalization, Kubelka-Munk
conversion, Kramers-Kronig analysis, ATR correction
Optional programs PLS quantitation, Curve fitting, Mapping, Macro platform
Validation programs Compliance to Japanese/European Pharmacopoeia and ASTM With laptop PC using rack
Operation log recording, Software protection by
GLP/GMP user name/password, Management of user level 630
320
Electronic signature, Data manipulation history recording,
FDA 21 CFR Part 11 Saving of measured interferogram/background spectrum/
(note1) manipulated spectra
260
15 - 30¡ C
Ambient conditions
592
Less than 70%
Power requirement AC100/120/220/230/240V 50/60Hz 160VA (note2)
(note1) IRsolution Agent software is needed to fully comply to FDA 21 CFR Part 11.
(note2) PC requires additional power.
PC Specifications
530
Desktop (SCSI interface for desktop PC is required.)
Type
260
Notebook (SCSI interface for notebook PC is required.)
OS Microsoft Windows 2000 (note3)
CPU Celeron 766MHz or Duron 850MHz or Pentium3 850MHz and later (note4)
Video 1024 x 768 pixels/256 color or better
(note5) Dimensions for PC and Printer depend on models.
RAM 128MB and more
HDD 30MB and more for free space
(note3) Windows is a trademark of Microsoft Corporation.
(note4) Celeron and Pentium are trademarks of Intel Corporation, Duron is trademark of
Advanced Micro Devices, Inc.
JQA-0376
SHIMADZU CORPORATION. International Marketing Division SHIMADZU DO BRASIL COMÉRCIO LTDA.
3. Kanda-Nishikicho 1-chome, Chiyoda-ku, Tokyo 101-8448, Japan Phone: 81(3)3219-5641 Fax. 81(3)3219-5710 Avenida Marqus de S‹o Vicente, 1771. Barra Funda CEP : 01139-003-S‹o Paulo-SP, Brasil
Cable Add.:SHIMADZU TOKYO Phone: (55)11-3611-1688 Fax. (55)11-3611-2209
SHIMADZU SCIENTIFIC INSTRUMENTS, INC. SHIMADZU (HONG KONG) LIMITED
7102 Riverwood Drive, Columbia, Maryland 21046, U.S.A. Suite 1028 Ocean Center, Harbour City, Tsim Sha Tsui, Kowloon HONG KONG
Phone: 1(410)381-1227 Fax. 1(410)381-1222 Toll Free: 1(800)477-1227 Phone: (852)2375-4979 Fax. (852)2199-7438
SHIMADZU EUROPA GmbH SHIMADZU INTERNATIONAL TRADING (SHANGHAI) Co., LTD. SHANGHAI OFFICE
Albert-Hahn-Strasse 6-10, 47269 Duisburg, F.R. Germany Phone: 49(203)7687-0 Fax. 49(203)766625 24th Floor, Shanghai Xin Hualian Building, No.755 Huaihai Zhong Lu, Shanghai, China
SHIMADZU (ASIA PACIFIC) PTE LTD. Phone: 86-21-6472-8442 Fax. 86-21-6472-8648
16 Science Park Drive #01-01 Singapore Science Park, Singapore 118227, Republic of Singapore Overseas Offices
Phone: 65-6778-6280 Fax. 65-6779-2935 Istanbul, Moscow
SHIMADZU SCIENTIFIC INSTRUMENTS (OCEANIA) PTY. LTD.
URL http://www.shimadzu.com
Units F, 10-16 South Street Rydalmere N.S.W. 2116, Australia
Phone: 61(2)9684-4200 Fax. 61(2)9684-4055
The contents of this brochure are subject to change without notice.