AUTOMATIC METER
READING SYSTEMS
Definition
• AMR
– Automatic Remote Meter Reading .
– Automating the process of measurement through
digital communication techniques.
METERING SYSTEM
PASTPAST
ELECTRO-MECHANICAL
Low Accuracy
Control – NIL
Communications - Expensive
Theft Detection – Poor
ELECTRO-MECHANICAL
Low Accuracy
Control – NIL
Communications - Expensive
Theft Detection – Poor
CURRENTCURRENT
DIGITAL SOLID STATE
High Accuracy
Control – LIMITED
Communications – External through Retrofit
Theft Detection – Node only
DIGITAL SOLID STATE
High Accuracy
Control – LIMITED
Communications – External through Retrofit
Theft Detection – Node only
NEXTGENNEXTGEN
NEXT GEN SMART METER & IT SYSTEM
Very High Accuracy
Control – FULL
Communications – Built in (on chip / PCB)
Theft Detection – High (Network level)
NEXT GEN SMART METER & IT SYSTEM
Very High Accuracy
Control – FULL
Communications – Built in (on chip / PCB)
Theft Detection – High (Network level)
 Ability to detect tamper events and outage occurrences.
 Remotely Connect/ Disconnect power supply through meter.
 Calculate transformer loading and sizing from interval data
 15 minute interval data gives accurate load information for supply
scheduling, switching operations, planning etc
 Monitor voltage at each premise to know conditions when to
operate capacitor switches or regulators
 Consistent and granular data for improved accuracy
Critical Benefits from AMRS
How AMR works ?
• Remotely reads customer meters and then transfers the
data into the billing system
• Reduce the need for meter readers to manually gather
utility meter readings each month.
AMR
ARCHITECTURE
PRIMARY COMPONENTS:
• Meter Interface Module
• Communication System
• Central Office Equipment
Meter interface module
– The AMR system starts at the
meter. Some means of translating
readings from rotating meter dials,
or cyclometer style meter dials, into
digital form is necessary in order to
send digital metering data from the
customer site to a central point.
– Electro - optical interface
– Signal Processing Electronics
– RAM & Program Memory
Retrofit Card
• Consists of a single PCB, which converts
CF pulses of Electronic Energy Meters to
Electrical pulses, accumulate them and
generate a meter reading with help of
Microprocessor.
• Microprocessor converts this data into
Power Line Modulation.
• Existing Meter Reading, Meter Constant
and Meter ID is stored in NV RAM of
Micro controller, before Retrofit is made
operational.
• One unit is incremented when Retrofit
senses the pulses equal to Meter
constant.
• The incremented unit are stored in the NV
RAM of the Micro controller.
Communications systems
Used for the transmission, or telemetry, of data and
control send signals between the meter interface units
and the central office.
1. GSM Based Communication
Single stage communication between Meter and central
station through GSM Modem
2. PLCC Based Communication
Single stage communication between Meter and central
station through electricity network
GSM Communication
GSM Based Communication
• GSM modem
• Antenna
GSM Modem
• Dual Band or Triband GSM GPRS modem
(EGSM 900/1800MHz) / (EGSM 900/1800 / 1900
MHz )
• Designed for GPRS, data, fax, SMS and voice
applications
• Fully compliant with ETSI GSM Phase 2+
specifications (Normal MS)
• Interfaces
• RS-232 through D-TYPE 9 pin connector
• Power supply through Molex 4 pin connector
• SMA antenna connector
• Toggle spring SIM holder
• Red LED Power on
• Green LED status of GSM / GPRS module
GSM Network In AMR
• Utilizing an existing cellular network for data transportation
requires no additional equipment or software, resulting in a
significant savings in both time and capital.
• Cellular technology utilizes an encryption technique to prevent
an outside source from receiving the transmitted data.
• The cellular network provides full two-way communications,
allowing scheduled reads, demand reads, alarm and event
reporting, power outage reporting and power restoration
reporting.
• Smart automated processes instead of manual work
• Accurate information from the network load to optimise
maintenance and investments
• Customized rates and billing dates.
• Streamlined high bill investigations.
• Detection of tampering of Meters.
• Accurate measurement of transmission losses.
• Better network performance and cost efficiency.
• Demand and distribution management.
• More intelligence to business planning.
Better company credibility.
ELECTRIC COMPANY BENEFITS
Advantages Of AMR System
CUSTOMER BENEFITS
• Precise consumption information
• Clear and accurate billing
• Automatic outage information and
faster recovery
• Better and faster customer service
• Flag potential high consumption before
customer gets a high bill.

Contenu connexe

Tendances

Tendances (20)

Smart Meters
Smart MetersSmart Meters
Smart Meters
 
Smart energy metering system
Smart energy metering systemSmart energy metering system
Smart energy metering system
 
Protection and control of Microgrid
Protection and control of MicrogridProtection and control of Microgrid
Protection and control of Microgrid
 
Automatic energy meter reading
Automatic energy meter readingAutomatic energy meter reading
Automatic energy meter reading
 
smart meter technical seminar report
smart meter technical seminar reportsmart meter technical seminar report
smart meter technical seminar report
 
AUTOMATIC METER READING BY SAIKIRAN PANJALA
AUTOMATIC METER READING BY SAIKIRAN PANJALAAUTOMATIC METER READING BY SAIKIRAN PANJALA
AUTOMATIC METER READING BY SAIKIRAN PANJALA
 
Electricity theft control
Electricity theft controlElectricity theft control
Electricity theft control
 
An approach to smart energy meter
An approach to smart energy meterAn approach to smart energy meter
An approach to smart energy meter
 
Smart Grid & WAMS
Smart Grid & WAMSSmart Grid & WAMS
Smart Grid & WAMS
 
Smart meter
Smart meterSmart meter
Smart meter
 
Smart energy meter ppt
Smart energy meter   pptSmart energy meter   ppt
Smart energy meter ppt
 
Smart energy meter (Updated)
Smart energy meter (Updated)Smart energy meter (Updated)
Smart energy meter (Updated)
 
OUTAGE MANAGEMENT SYSTEM
OUTAGE MANAGEMENT SYSTEMOUTAGE MANAGEMENT SYSTEM
OUTAGE MANAGEMENT SYSTEM
 
Smart Meters
Smart MetersSmart Meters
Smart Meters
 
concept of resilience and self healing in smart grid
concept of resilience and self healing in smart gridconcept of resilience and self healing in smart grid
concept of resilience and self healing in smart grid
 
Cloud computing for smart grid applications
Cloud computing for smart grid applicationsCloud computing for smart grid applications
Cloud computing for smart grid applications
 
Smart meters
Smart metersSmart meters
Smart meters
 
Smart Grid Advanced Metering Infrastructure
Smart Grid Advanced Metering InfrastructureSmart Grid Advanced Metering Infrastructure
Smart Grid Advanced Metering Infrastructure
 
Power qualty conditioners
Power qualty conditionersPower qualty conditioners
Power qualty conditioners
 
Smart Grid
Smart GridSmart Grid
Smart Grid
 

Similaire à AUTOMATIC METER READING SYSTEMS

it_in_power_distribution.ppt
it_in_power_distribution.pptit_in_power_distribution.ppt
it_in_power_distribution.ppt
YuvrajSaigal
 
AMR & EMS- Automated Meter Reading and Energy Management System
AMR & EMS- Automated Meter Reading and Energy Management SystemAMR & EMS- Automated Meter Reading and Energy Management System
AMR & EMS- Automated Meter Reading and Energy Management System
Sushant Kumar Sinha
 
Raritan BCM Data Sheet
Raritan BCM Data SheetRaritan BCM Data Sheet
Raritan BCM Data Sheet
Mike Hogan
 
GSM Based Prepaid Remote Energy Meter & OverVoltage Protection
GSM Based Prepaid Remote Energy Meter & OverVoltage ProtectionGSM Based Prepaid Remote Energy Meter & OverVoltage Protection
GSM Based Prepaid Remote Energy Meter & OverVoltage Protection
Pringil Alphanso
 
Power theft detection via plc
Power theft detection via plcPower theft detection via plc
Power theft detection via plc
bbshashanka
 
Lecture+9+-+SCADA+Systems.pdf
Lecture+9+-+SCADA+Systems.pdfLecture+9+-+SCADA+Systems.pdf
Lecture+9+-+SCADA+Systems.pdf
SmritiGarg21
 

Similaire à AUTOMATIC METER READING SYSTEMS (20)

it_in_power_distribution.ppt
it_in_power_distribution.pptit_in_power_distribution.ppt
it_in_power_distribution.ppt
 
AMR & EMS- Automated Meter Reading and Energy Management System
AMR & EMS- Automated Meter Reading and Energy Management SystemAMR & EMS- Automated Meter Reading and Energy Management System
AMR & EMS- Automated Meter Reading and Energy Management System
 
Concepts of smart meter
Concepts of smart meterConcepts of smart meter
Concepts of smart meter
 
AUTOMATIC ENERGY METER READING SYSTEM FOR BILLING PURPOSE
AUTOMATIC ENERGY METER READING SYSTEM FOR BILLING PURPOSEAUTOMATIC ENERGY METER READING SYSTEM FOR BILLING PURPOSE
AUTOMATIC ENERGY METER READING SYSTEM FOR BILLING PURPOSE
 
AUTOMATIC METER READING
AUTOMATIC METER READINGAUTOMATIC METER READING
AUTOMATIC METER READING
 
GSM Prepaid Meter PPT.ppt
GSM Prepaid Meter PPT.pptGSM Prepaid Meter PPT.ppt
GSM Prepaid Meter PPT.ppt
 
20BEE042 5th semester Internship PPT.pptx
20BEE042 5th semester Internship PPT.pptx20BEE042 5th semester Internship PPT.pptx
20BEE042 5th semester Internship PPT.pptx
 
Smart Grid – What’s in it for me? Customer Benefits and Engineering Career Op...
Smart Grid – What’s in it for me? Customer Benefits and Engineering Career Op...Smart Grid – What’s in it for me? Customer Benefits and Engineering Career Op...
Smart Grid – What’s in it for me? Customer Benefits and Engineering Career Op...
 
Engineering the Smart Grid
Engineering the Smart GridEngineering the Smart Grid
Engineering the Smart Grid
 
Raritan BCM Data Sheet
Raritan BCM Data SheetRaritan BCM Data Sheet
Raritan BCM Data Sheet
 
Photovoltaic Training Course - Module 3.2 - control system components and inf...
Photovoltaic Training Course - Module 3.2 - control system components and inf...Photovoltaic Training Course - Module 3.2 - control system components and inf...
Photovoltaic Training Course - Module 3.2 - control system components and inf...
 
GSM Based Prepaid Remote Energy Meter & OverVoltage Protection
GSM Based Prepaid Remote Energy Meter & OverVoltage ProtectionGSM Based Prepaid Remote Energy Meter & OverVoltage Protection
GSM Based Prepaid Remote Energy Meter & OverVoltage Protection
 
Unit ii
Unit   iiUnit   ii
Unit ii
 
SICAM FCM – Feeder Condition Monitor
SICAM FCM – Feeder Condition MonitorSICAM FCM – Feeder Condition Monitor
SICAM FCM – Feeder Condition Monitor
 
Power theft detection via plc
Power theft detection via plcPower theft detection via plc
Power theft detection via plc
 
Lecture+9+-+SCADA+Systems.pdf
Lecture+9+-+SCADA+Systems.pdfLecture+9+-+SCADA+Systems.pdf
Lecture+9+-+SCADA+Systems.pdf
 
Lecture+9+-+SCADA+Systems.pptx
Lecture+9+-+SCADA+Systems.pptxLecture+9+-+SCADA+Systems.pptx
Lecture+9+-+SCADA+Systems.pptx
 
BPSK Modulation and Demodulation with Power Line Carrier Communication and GS...
BPSK Modulation and Demodulation with Power Line Carrier Communication and GS...BPSK Modulation and Demodulation with Power Line Carrier Communication and GS...
BPSK Modulation and Demodulation with Power Line Carrier Communication and GS...
 
Smart meters.pptx
Smart meters.pptxSmart meters.pptx
Smart meters.pptx
 
Low cost ppt final
Low cost ppt finalLow cost ppt final
Low cost ppt final
 

Plus de Divya Yennam (9)

SIMULATION OF MULTIMODE DC-DC CONVERTER FOR EV APPLICATIONS
SIMULATION OF MULTIMODE  DC-DC CONVERTER FOR EV APPLICATIONSSIMULATION OF MULTIMODE  DC-DC CONVERTER FOR EV APPLICATIONS
SIMULATION OF MULTIMODE DC-DC CONVERTER FOR EV APPLICATIONS
 
Hvdc kundur-textbook
Hvdc kundur-textbookHvdc kundur-textbook
Hvdc kundur-textbook
 
Electric Grid
Electric GridElectric Grid
Electric Grid
 
WIDE AREA MANAGEMENT SYSTEM
WIDE AREA MANAGEMENT SYSTEMWIDE AREA MANAGEMENT SYSTEM
WIDE AREA MANAGEMENT SYSTEM
 
Smart grid
Smart gridSmart grid
Smart grid
 
Monitoring PMU,SMART METERS and measurement technologies
Monitoring PMU,SMART METERS and measurement technologiesMonitoring PMU,SMART METERS and measurement technologies
Monitoring PMU,SMART METERS and measurement technologies
 
SCADA
SCADASCADA
SCADA
 
communication technologies and power system automation
communication technologies and power system automationcommunication technologies and power system automation
communication technologies and power system automation
 
Sssc
SsscSssc
Sssc
 

Dernier

scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...
scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...
scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...
HenryBriggs2
 

Dernier (20)

FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced LoadsFEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
 
kiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal loadkiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal load
 
Bridge Jacking Design Sample Calculation.pptx
Bridge Jacking Design Sample Calculation.pptxBridge Jacking Design Sample Calculation.pptx
Bridge Jacking Design Sample Calculation.pptx
 
Online electricity billing project report..pdf
Online electricity billing project report..pdfOnline electricity billing project report..pdf
Online electricity billing project report..pdf
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - V
 
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKARHAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
 
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
 
Introduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaIntroduction to Serverless with AWS Lambda
Introduction to Serverless with AWS Lambda
 
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
COST-EFFETIVE  and Energy Efficient BUILDINGS ptxCOST-EFFETIVE  and Energy Efficient BUILDINGS ptx
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
 
scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...
scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...
scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...
 
Work-Permit-Receiver-in-Saudi-Aramco.pptx
Work-Permit-Receiver-in-Saudi-Aramco.pptxWork-Permit-Receiver-in-Saudi-Aramco.pptx
Work-Permit-Receiver-in-Saudi-Aramco.pptx
 
Minimum and Maximum Modes of microprocessor 8086
Minimum and Maximum Modes of microprocessor 8086Minimum and Maximum Modes of microprocessor 8086
Minimum and Maximum Modes of microprocessor 8086
 
Employee leave management system project.
Employee leave management system project.Employee leave management system project.
Employee leave management system project.
 
Online food ordering system project report.pdf
Online food ordering system project report.pdfOnline food ordering system project report.pdf
Online food ordering system project report.pdf
 
Hostel management system project report..pdf
Hostel management system project report..pdfHostel management system project report..pdf
Hostel management system project report..pdf
 
AIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech studentsAIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech students
 
Computer Networks Basics of Network Devices
Computer Networks  Basics of Network DevicesComputer Networks  Basics of Network Devices
Computer Networks Basics of Network Devices
 
Computer Lecture 01.pptxIntroduction to Computers
Computer Lecture 01.pptxIntroduction to ComputersComputer Lecture 01.pptxIntroduction to Computers
Computer Lecture 01.pptxIntroduction to Computers
 
Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPT
 
Hazard Identification (HAZID) vs. Hazard and Operability (HAZOP): A Comparati...
Hazard Identification (HAZID) vs. Hazard and Operability (HAZOP): A Comparati...Hazard Identification (HAZID) vs. Hazard and Operability (HAZOP): A Comparati...
Hazard Identification (HAZID) vs. Hazard and Operability (HAZOP): A Comparati...
 

AUTOMATIC METER READING SYSTEMS

  • 2. Definition • AMR – Automatic Remote Meter Reading . – Automating the process of measurement through digital communication techniques.
  • 3. METERING SYSTEM PASTPAST ELECTRO-MECHANICAL Low Accuracy Control – NIL Communications - Expensive Theft Detection – Poor ELECTRO-MECHANICAL Low Accuracy Control – NIL Communications - Expensive Theft Detection – Poor CURRENTCURRENT DIGITAL SOLID STATE High Accuracy Control – LIMITED Communications – External through Retrofit Theft Detection – Node only DIGITAL SOLID STATE High Accuracy Control – LIMITED Communications – External through Retrofit Theft Detection – Node only NEXTGENNEXTGEN NEXT GEN SMART METER & IT SYSTEM Very High Accuracy Control – FULL Communications – Built in (on chip / PCB) Theft Detection – High (Network level) NEXT GEN SMART METER & IT SYSTEM Very High Accuracy Control – FULL Communications – Built in (on chip / PCB) Theft Detection – High (Network level)
  • 4.  Ability to detect tamper events and outage occurrences.  Remotely Connect/ Disconnect power supply through meter.  Calculate transformer loading and sizing from interval data  15 minute interval data gives accurate load information for supply scheduling, switching operations, planning etc  Monitor voltage at each premise to know conditions when to operate capacitor switches or regulators  Consistent and granular data for improved accuracy Critical Benefits from AMRS
  • 5. How AMR works ? • Remotely reads customer meters and then transfers the data into the billing system • Reduce the need for meter readers to manually gather utility meter readings each month.
  • 6.
  • 8. PRIMARY COMPONENTS: • Meter Interface Module • Communication System • Central Office Equipment
  • 9. Meter interface module – The AMR system starts at the meter. Some means of translating readings from rotating meter dials, or cyclometer style meter dials, into digital form is necessary in order to send digital metering data from the customer site to a central point. – Electro - optical interface – Signal Processing Electronics – RAM & Program Memory
  • 10. Retrofit Card • Consists of a single PCB, which converts CF pulses of Electronic Energy Meters to Electrical pulses, accumulate them and generate a meter reading with help of Microprocessor. • Microprocessor converts this data into Power Line Modulation. • Existing Meter Reading, Meter Constant and Meter ID is stored in NV RAM of Micro controller, before Retrofit is made operational. • One unit is incremented when Retrofit senses the pulses equal to Meter constant. • The incremented unit are stored in the NV RAM of the Micro controller.
  • 11. Communications systems Used for the transmission, or telemetry, of data and control send signals between the meter interface units and the central office. 1. GSM Based Communication Single stage communication between Meter and central station through GSM Modem 2. PLCC Based Communication Single stage communication between Meter and central station through electricity network
  • 13. GSM Based Communication • GSM modem • Antenna
  • 14. GSM Modem • Dual Band or Triband GSM GPRS modem (EGSM 900/1800MHz) / (EGSM 900/1800 / 1900 MHz ) • Designed for GPRS, data, fax, SMS and voice applications • Fully compliant with ETSI GSM Phase 2+ specifications (Normal MS) • Interfaces • RS-232 through D-TYPE 9 pin connector • Power supply through Molex 4 pin connector • SMA antenna connector • Toggle spring SIM holder • Red LED Power on • Green LED status of GSM / GPRS module
  • 15. GSM Network In AMR • Utilizing an existing cellular network for data transportation requires no additional equipment or software, resulting in a significant savings in both time and capital. • Cellular technology utilizes an encryption technique to prevent an outside source from receiving the transmitted data. • The cellular network provides full two-way communications, allowing scheduled reads, demand reads, alarm and event reporting, power outage reporting and power restoration reporting.
  • 16. • Smart automated processes instead of manual work • Accurate information from the network load to optimise maintenance and investments • Customized rates and billing dates. • Streamlined high bill investigations. • Detection of tampering of Meters. • Accurate measurement of transmission losses. • Better network performance and cost efficiency. • Demand and distribution management. • More intelligence to business planning. Better company credibility. ELECTRIC COMPANY BENEFITS Advantages Of AMR System
  • 17. CUSTOMER BENEFITS • Precise consumption information • Clear and accurate billing • Automatic outage information and faster recovery • Better and faster customer service • Flag potential high consumption before customer gets a high bill.