Continuous Emission Monitoring Systems

service@a1-cbiss.com
sales@a1-cbiss.com

Market Leading Technical & Legislative Consultancy
Complete Turnkey Solution Providers
MCERTS Accredited Hardware & Software
Cradle to Grave Support Approach
Continuous Emission Monitoring Systems
For over 20 years, a1-cbiss continue to be a market leading
• MCERTS accredited emission monitoring systems provider
•  pecialising in design, manufacture and integration
S

For over a decade, a1-cbiss have built a relationship
with Environnement SA to provide a range of
MCERTS accredited, market leading Continuous
Emission Monitoring Systems to meet your
legislative requirements

•  omplete environmental monitoring turnkey
C
solutions
•  ully MCERTS accredited Data Acquisition
F
Software
•  upported by the industry’s largest service
S
network across the UK

2.	 Dedicated Project Management
	 •  very project is fully supported by a
E
dedicated project manager to provide one
point of contact throughout every phase
through to completion

1. CEMS Management Consultancy

	 •  arket leading technical  legislative
M
consultancy
	 •  omplete turnkey solution providers
C
	 •  radle to grave support
C
approach
3.	n-House Project Design,
I
Build  Integration
	 •  egular design reviews 
R
client feedback support
revisions as the project
evolves
	 •  ystems are all custom
S
built in-house by factory
trained engineers
	
•  actory Acceptance
F
Tests (FAT’s) carried
out with all relevant
inspection certification
issued

5.	
After Sales Service  Support
	 • 
Bespoke contracts tailored to site specific, legislative
or budgetary requirements offering peace of mind that
equipment is covered for all eventualities
	 • 
24/7 regional service support
	 • 
From 6 hour callout response

1

Tel: 0151 666 8300
www.a1-cbiss.com

4.	 Installation  Commissioning
	 •  xpert installation team with over 10 years experience to
E
integrate, calibrate  commission your system
	 • Site Acceptance Tests (SAT’s) carried out

2
Environnement SA MIR-FT

Environnement SA MIR-9000
(Plus CLD Option)

Fourier Transform Infra-Red

Datasheet

Multi-Gas Infrared GFC Analyser

Datasheet
Installed across the majority of the UK’s municipal waste
incinerators, the MIR-FT Utilises Fourier Transform Infra-Red
(FT-IR) to offer multiple gas measurements simultaneously,
including NO, NO2, SO2, NH3, HCl and CO.
With the emissions limits tightening and new gases being
introduced, this instrument allows future gas upgrades,
providing the solution for today and what may happen
tomorrow. Designed to operate under legislation such as
2000/76/EC (WID) and 2001/80/EC (LCPD), The MIR-FT
offers maximum availability and complete compliance with
QAL 1 of EN14181  EN15267-3.

The MIR-FT is rack mounted in air conditioned enclosures.
Complete systems would normally comprise of:
•  ample extraction and conditioning probe (with integrated
S
temperature, pressure and flow measurement)
•  eated sample lines
H
•  utomatic calibration units
A
• nstrument air drying system
I
•  DAS Data Acquisition Software
C

Features:
•  esigned for measurements in wet and corrosive sample
D
gases
• Future upgrades possible
• Excellent calibration stability
• Automatic spectral interference corrections
• Fast and simultaneous measurements for multiple gases
• Reproducible and accurate
• Windows based PC driven software with on-board data

acquisition
• Capable of automatic QAL 3 checks when used in

conjuction with IVIS unit
• MCERTS Certified


With over 1500 installations world wide, the MIR-9000 is a proven
Continuous Emissions Monitoring system across a wide range of
industries. All measurements are supplied dry as the sample is
conditioned at the extraction point via the SEC drying system before
being transported down a cool polytube line.
The MIR-9000-CLD option utilises the Standard Reference Method
(SRM) for the monitoring of NO N2O NO2 NOx CO CO2 SO2 and
O2. The MIR-9000-CLD analyser is a free standing monitoring
system that incorporates three monitoring technologies, these are
Chemiluminescence for low level NOx measurement, Infra-Red Gas
Filter Correlation for CO, CO2 etc and finally Paramagnetic for O2.
Designed to operate under legislation such as 2000/76/EC (WID)
and 2001/80/EC (LCPD), The MIR-9000 offers maximum availability
and complete compliance with QAL 1 of EN14181  EN15267-3.
Features:
• Measures from 1 - 10 gases simultaneously
• Built-in data logger for 7 additional parameters (flow, pressure,

temperature or any other analogue input)
Complete systems would normally comprise of:

• Real time graphic display


• Sample extraction and conditioning probe (with integrated

temperature, pressure and flow measurement)

• Interactive menu-driven software allowing ease of operation


• Cold sample lines


• Readings measured and expressed on a dry basis


• Unheated sample line utilising permapure drying technology

• On-board oxygen correction for environmental reporting


• Automatic calibration units

• Instrument air drying system


• Optional stack pressure, temperature and flow measurements

available

•  DAS Data Acquisition Software
C

• MCERTS Certified


Specification

Specification
Applications:
• Municipal, Industrial  Hospital

Waste Incinerators
• Power  Combustion

• Biomass

• Cement Kilns

• Pulp  Paper

• DeNOx (SNCR, SCR)


3

Specification:
Z
 ero drift: ± 1% full scale/30 days
Span drift: ± 1% full scale/30 days
Repeatability: ± 2% full scale
Lower detectable limit: 2% full scale
Response time: 2mins depending on
the gas
Power supply: 220V, ± 15%, 50-60Hz,
200VA
Weight: 20 kg approximately
Operating temperature: +10°C to
+35°C

Tel: 0151 666 8300
www.a1-cbiss.com

Applications:

Gas 	
NO 	
NO2 	
CO 	
CO2 	
SO2 	
N2O 	
HCl 	
NH3 	
H2O 	
O2 	

MCERTS Certification Ranges
0-200mg/m3 - 0-600mg/m3
0-200mg/m3
0-75mg/m3 - 0-300mg/m3
0-25%
0-75mg/m3 - 0-500mg/m3
0-100mg/m3
0-15mg/m3 - 0-90mg/m3
0-15mg/m3
0-30%
0-25%

Specification:

• Municipal, Industrial  Hospital Waste

Incinerators

Repeatability: 2% of Full Scale (F.S.)

• Thermal Oxidisers
• Exhaust Gas Analysis
•  tandard Reference Method for VOC
S
Monitoring
• Laboratories and Research Centres
• Process Control
• Combustion Monitoring

Zero drift: 2% F.S. / 30 days
Span drift: 1% F.S. / 7 days
Linearity: 1% F.S.
Power supply: 80 - 230V, 50-60 Hz
Consumption: 300 VA
Serial link: RS232, RS422
Operating temperature: +5°C to +40°C

Gas 	 MCERTS Certification Ranges
NO (CLD)	 0-20mg/m3 - 0-2000mg/m3
NO2 (CLD) 	 0-20mg/m3
NOx (CLD) 	 0-20mg/m3
NO		
0-100mg/m3 - 0-500mg/m3
CO 		
0-75mg/m3 - 0-500mg/m3
CO2		
0-25%
SO2 		
0-75mg/m3 - 0-200mg/m3
N2O 		
0-20mg/m3 - 0-200mg/m3
HCl 		
0-15mg/m3 - 0-100mg/m3
CH4 		
0-10mg/m3 - 0-200mg/m3
O2 		
0-10% - 0-25%

4
Environnement SA
Graphite 52M

Environnement SA MIR-IS
Infra-Red Gas Filter Correlation

Datasheet

Heated FID Volatile Organic
Compounds Analyser

Datasheet

Designed to operate under legislation such as 2000/76/
EC (WID) and 2001/80/EC (LCPD), The MIR-IS offers
maximum availability and complete compliance with QAL 1
of EN14181  EN15267-3.
Based on the MIR-9000, the in-situ multi-gas CEM system
is a compact extractive monitoring system, providing fast
response, close coupled measurements.

For multi-gas monitoring, in less than 40 milliseconds, the
MIR-IS monitors each selected gas by Infra-Red Gas Filter
Correlation principle. This technology eliminates cross
sensitivity from other present gases and provides high
accuracy.
The MIR-IS also monitors temperature, flow and pressure
integrated into the sample extraction probe.
Features:
• n-situ extractive installation
I
• Measures from 1-10 gases simultaneously
•  ase of installation: single stack entry, sample line not
E
required therefore reducing costs
• ntegrated air drying and handling system
I
•  he Infra-red technology eliminates cross sensitivity from
T
other present gases and provides high accuracy
•  ast response for process control
F
•  uto calibration check capability
A
•  owerful remote functions
P
•  ynoptic flow diagram display
S
• nteractive menu driven software
I
•  ptional stack pressure, temperature and flow
O
measurements available
•  CERTS Certified
M

The FID is temperature controlled up to 191°C to eliminate
condensation. Extremely compact and with a very short
response time, this heated FID provides continuous
monitoring of total VOC’s, in compliance with the Waste
Incineration Directive and EN12619 standard as written in
most WID permits.

The Graphite 52M is fully supported by MCERTS
certified CDAS Elite Data Aquisition Software and a
comprehensive service and support package.
Equipped with one burner placed in a heated block, the
Graphite 52M allows continuous and accurate Total VOC
monitoring.

Specification

Specification
Applications:
• Municipal, Industrial  Hospital

Waste Incinerators
• Power  Combustion
• Biomass
• Cement Kilns
• Pulp  Paper
• DeNOx (SNCR, SCR)

5

Specification:
•  aterial in contact with effluent:
M
Stainless Steel, Hastelloy or PTFE
•  umber of gases monitored: up to 10
N
•  epeatability: ± 2% of full scale
R
•  ero drift: ± 2% of full scale/30 days
Z
•  pan drift: ± 2% of full scale/30 days
S
•  inearity: ± 1% of full scale
L
•  owest detectable limit: ± 2% of full
L
scale
•  ata storage: last 3000 averages
D
•  igital output: RS232/422
D
•  robe length: 700x1000x1500mm
P
•  eight: 30kg approximately
W
•  ower: 115/230VAC, 50/60Hz, 700VA
P
•  perating temperature: -15°C to
O
+50°C

Tel: 0151 666 8300
www.a1-cbiss.com

Gas 	
NO 	
N2O	
CO 	
CO2 	
SO2 	
HCl 	
CH4 	
O2 	

MCERTS Certification Ranges
0-100mg/m3 - 0-500mg/m3
0-20mg/m3 - 0-200mg/m3
0-75mg/m3 - 0-500mg/m3
0-25%
0-75mg/m3 - 0-200mg/m3
0-15mg/m3 - 0-100mg/m3
0-10mg/m3 - 0-200mg/m3
0-10% - 0-25%

Features:
• Detector placed in a heated oven, up to 191°C

allowing measurement of high concentrations of heavy
hydrocarbons
• Fast response time

• Real time graphic display with interactive menu driven

software
• Integrated zero air catalyst

• Dual stream monitoring by independent detectors

available
• User selectable ranging

• Very low limits of detection

• Hydrogen/Helium fuel supply thus reducing oxygen

interference
• Fully compatible with the Environnement S.A. MIR-FT 

MIR-9000 CEM systems
• MCERTS Certified


Applications:
• Municipal, Industrial  Hospital

Waste Incinerators
• Thermal Oxidisers
• Exhaust Gas Analysis
• Standard Reference Method for VOC Monitoring
• Laboratories and Research Centres
• Process Control
• Combustion Monitoring
MCERTS Certification Range:
TOC: 0-15mg/m3

Specification:
•  anges: 0-10/100/1000/10000 ppm or user programmable
R
range up to 50 000 ppm
•  ccuracy:  1% of the displayed value between 15% and
A
100% of the F.S.
•  ower detectable limit: 0.05 ppm of the 10 ppm range
L
•  esponse time:  1 sec. (T90)
R
•  ero drift: 1%/24h F.S. 2%/7 days F.S.
Z
•  pan drift: 1% / 7 days F.S.
S
•  inearity: 1% for concentration between 10 % and 90%
L
of the scale
•  emperature of the heated block: up to 191°C
T
•  eight: 22kg approximately
W
• Power supply: 230 VAC, 50Hz or 115 VAC, 60 Hz
• Operating temperature: +5°C to +40°C

6
Syngas Monitoring System

PCME QAL181  QAL991
Particulate Monitoring Systems

Datasheet

Datasheet
The PCME QAL181 utilises Proscatter to measure the
scattered forward light from a laser source. The QAL991
utilises PCME’s unique AC Electrodynamic technology, an
advanced Triboelectric method.

Syngas Monitoring System (SMS) is designed to monitor
and report the constituents of the syngas produced by the
gasification process. The SMS provides live CV value,
essential to determine your qualification for renewable
obligation certificates (ROCS). In modern gasification where
syngas composition is paramount for determining the
calorific value, the a1-cbiss SMS provides an accurate, cost
effective solution.

The QAL181  QAL991 are ideal where high accuracy and
stability are required or when bag filters are not installed,
designed to operate under legislation such as 2000/76/EC
(WID) and 2001/80/EC (LCPD), the QAL181 offers complete
compliance with EN14181, EN13284-2  EN15267-3.

The SMS utilises varying degrees of high temperature
probes ranging from stainless steel through to inconel
and water cooled if required. The SMS gas is continuously
taken, conditioned and analysed at a single sampling point.

Features:
• Automatic self-checks which record results for QAL3 tests


Sample preparation and conditioning is a key element
of the system, upon which substantially depends on the
correctness of the consequent measurement, as well as the
lifetime of the measurement sensors.

• Capability to conduct linearity checks in accordance with

EN14181
• Real time graphic display with interactive menu driven

software
• Very low limits of detection

With online calibration capability, the QAL181  QAL991
minimises drift but also offers the QAL3 facility when used
with CDAS Elite Data Acquisition Software.

Specification

• MCERTS Certified


Specification
Applications:

Specification QAL991

Specification QAL181

• Municipal, Industrial  Hospital

Waste Incinerators

•  ertification range: 0-15mg/m3 (as
C
stated in QAL1 approval)

• Thermal Oxidisers

•  easurement capability: 0-100mg/m3
M

• Exhaust Gas Analysis

•  ong term zero drift: 0.1mg/m3
L

• Minimum detection limit of  0.05

mg/m3 and certification range of
0-15 mg/m3 and measurement range
0-200 mg/m3

• Laboratories and Research Centres

• nspection frequency: 6 months
I

• Process Control

•  o velocity restrictions in processes
N
between 8m/s-20m/s

Data Acquisition Software
In conjunction with the SMS a1-cbiss are able to offer
market leading MCERTS accredited data acquisition and
reporting software complete with live CV calculation.

• Combustion Monitoring
MCERTS Certification Range:
TPM: 0-15mg/m3

•  onstant velocity required outside
C
this range
•  or stack diameters: 500mm to 3m
F
(multi-sensor configuration required
for stack  3m)
•  nclosure temperature rating -25°C to
E
+55°C

7

Tel: 0151 666 8300
www.a1-cbiss.com

• Long term zero drift: 0.1mg/m3


Specifications:
• Power supply: 110v or 230v

• Inspection frequency: 3 months

• Air purge requirements: 30 to 40

litres/ minute unaffected by changes
in velocity

How Does the System Work?
The sample intake is provided through a heated sample
probe with large surface filtration. The sample conditioning
system includes a high performance cooler. The heat
exchanger is constructed in a way to minimise the loss of
water soluble compounds.
The sample gas is appropriately filtered in order to remove
solid particulates and any acid aerosols. The sample
conditioning equipment in total consists of a condensate
detector, condensate pump and sample pump.

• Enclosure temperature rating -25°C to

+55°C

Applications:
•  asification
G
• 
Anaerobic Digestion
•  iogas
B

• Probe length 700mm or 1400mm


• Operating temperature: +5°C to +40°C

What Does the System Measure?
•  O • H2 • CO2 • O2 • CH4
C
•  ption to add additional parameters to meet gasification
O
process

Model
Gas Accuarcy
Stability
Gascard NG CO +/- 2% of range 2% of range over 12 mths
CH4
CO2
K1550

H2

+/- 2% FSD

1% FSD per month

8
AMESA

Bacharach

Dioxins  Furans
Emissions Sampler

Combustion Analysers

Datasheet

ECA 450
The AMESA is fast becoming the
system of choice for new build energy
from waste plants for the continuous
sampling of dioxins and furans as
standard.

The ECA 450 from Bacharach is ideal for professionals to
conduct accurate combustion and emissions tests whilst
improving overall combustion efficiency, reducing fuel
costs, and determining emissions compliance.
The ECA 450 takes continuous samplings of furnaces,
boilers and other industrial combustion equipment for up
to 8 hours and generates precise, reliable combustion and
environmental measurements and calculations. It generates
this complex data easily — even at selected intervals
- enabling plants to make more accurate equipment
adjustments and better assess pollution levels.

The continuous dioxin and furan
sampling system makes it possible to
sample trace pollutants such as dioxins
and furans.
The AMESA® is MCERTS accredited
and complies with EN1948. Fully
supported by AMLEIT monitoring
software and MCERTS Certified CDAS
Elite Data Aquisition Software.

Specification
Applications:

Features  Benefits:

MCERTS Certification Ranges:

• Municipal, Hazardous  Hospital

Waste Incineration

•  ontinuous automatic sampling
C
giving a more accurate
representation of the sample

Measures:
•  xygen (O2), Carbon Monoxide (CO), Nitric Oxide (NO),
O
Nitrogen Dioxide (NO2), Sulphur Dioxide (SO2)
•  ombustibles, Temperature  Draft. It also calculates
C
combustion efficiency, excess air, carbon dioxide, NOx
(Nitrogen Oxides) and pollution units

Features and Benefits:
•  arge, easy-to-read fluorescent display that is visible from
L
wide angles
•  odular design lets you add sensors as your needs
M
change
•  uilt-in printer and complete data downloading to a PC
B
capability
•  tores over 1000 individual combustion and/or pressure
S
test records, which can later be recalled for viewing or
printing

Isokinetic Sampling Velocity:

• Energy From Waste (EFW)

• Production Plants

• Recycling Plants

• Cement Kilns

• Metallurgic Plants

• Pulp and Paper


•  utomated datalogging recording
A
over a period of 6 hours up to 30
days
•  atalogging including: flue gas
D
velocity, sample gas flow volume,
flue gas temperature and cartridge
temperature as half-hourly average
•  imultaneous monitoring of up to
S
4 sample streams with 1 AMESA
system
•  emote control functionality available
R
•  educed costs due to optimisation of
R
the built-in dioxin reduction stages

PCA 3

•  -20m/s
2
a1-cbiss are pleased to announce the
launch of the new Bacharach PCA®3,
the industry’s first advanced portable
combustion analyser with a full colour
graphic display for superior visibility
and user-friendly interface and the most
sensor configuration flexibility in its
class.

Features and Benefits:
• Sensors can easily be added or

removed in the field without down
time, using the B-Smart®
pre-calibrated sensor options.

Measures:
• n addition to the included Oxygen
I
(O2) and Carbon Monoxide (CO)
The PCA®3 is the definitive combustion
sensors, the PCA®3 can be ordered
and emissions analyser that enables
with CO (high), Nitric Oxide (NO),
fast and accurate measurement
Nitrogen Dioxide (NO2) and Sulphur
for on-demand or semi-continuous
Dioxide (SO2) sensors.
sampling of light industrial, institutional,
commercial and residential furnaces,
boilers and appliances.

•  lue transparency
F

9

Tel: 0151 666 8300
www.a1-cbiss.com

10
CDAS Report

C D A S

CDAS Report is an offline package that allows
reports and graphs to be generated. CDAS Report
offers the flexibility to configure reports to meet the
requirements of the site permit and the EA.
Sira MC090153/00

Environmental CDAS Data Acquisition Reporting and Network Packages

Each report can be generated at any time without
interrupting the data collection process. Reports are
simple to generate using the report wizard.

What is CDAS?
EN14181

CDAS is the market leading MCERTS accredited (parts A, B, C1  C2) Data Acquisition package that
retrieves data from a range of instruments for CEMS, Gas Detection and Sampling applications. The CDAS
software meets the stringent demands of WID, LCPD, EN14181, IPPC and customer specific requirements.
From data logging to data processing, trending and
reporting, the CDAS software suite provides the
flexibility to supply a complete solution for your site.

Standard CDAS Features:

Typical communications protocols include serial,
Ethernet, analogue and digital I/O. Other protocols
are supported such as Modbus, OPC and
PROFIBUS, for easy interfacing to a PLC.

CDAS eases the burden of EN14181 compliance as it
allows application of QAL2 calibration functions and
performs automatic QAL3 Testing

• Dual Redundant Data Collection

• Automatic Period Reports
• Communicates via Remote Analogue I/O
• Correction to Standard Reference Conditions
•  llows application of EN14181 Calibration
A
Functions

C D A S

• Performs Automatic EN14181 QAL3 Testing
• Graphing Options
• Configurable Alarms
• Searchable Alarm History Screen

Based on market feedback and regular
communications with existing customers,
a1-cbiss are launching the new CDAS
platform with improved features to support
evolving requirements
NEW CDAS Features in 2011:
• Windows 7 Compatability
• Specific Gas Bottles Associated to QAL3

Test

Data Collection, Processing  Visualisation
CDAS acquires data in real time. Real time data then
converted to:
• Raw Data (Instrument Value)


CDAS allows the data to be viewed in a fully
configurable screen layout to support individual
preferences via preset and customisable data
channels.

Dual Redundancy
To maximise data capture, two copies of CDAS can
be set up in a duty/standby dual redundant
arrangement. The standby machine connects to the
duty machine and is supplied with live data. If the
standby machine detects that the live data supply is
interrupted then it will attempt to collect data from the
instruments itself.

• Simultaneously Performs Multiple QAL3

Tests from a Mixed Gas Bottle
• Multi Language Support

• Calibrated Data (EN14181 QAL2 Calibration

Function)
• Corrected Data (Reference Conditions)

• Adjusted Data (Reportable Values)

A data file for each of the conditions above is written
to the hard disk. CDAS does not delete any data
that it has recorded.

11

Tel: 0151 666 8300
www.a1-cbiss.com

12
Service  Support

Service Contract Benefits

The a1-cbiss philosophy differs from our
competitors in that we firmly believe quality should
continue far beyond supply. All systems are
supported by our dedicated service department to
provide repair, calibration, preventative maintenance,
software support and remote diagnostics - 24 hour /
7 days per week to our customers

Our wealth of knowledge and experience ensures
you meet legislative requirements with no downtime,
therefore maximising your investment. Additional
benefits include:

With the largest dedicated CEMS service support
network in the industry, a1-cbiss have fully factory
trained industry specialists on hand to provide full
customer service and support

• OMA - Pre audit check and OMA audit

attendance

Ongoing service  support is integral to the a1-cbiss
offering. With a comprehensive service  support
package that is fully flexible to meet customer
specific, legislative or budgetary requirements,
offering peace of mind that equipment is covered for
all eventualities

• Flexibility to suit your requirements
• EN14181 consultancy and compliance support

• Full operator system training

• Reduced downtime to improve plant efficiency


Typical Service Contract Comprises:
• 4 scheduled service and calibration visits

per year
• All parts, labour and travel inclusive

• Guaranteed response time from 6 hours

• Site allocated service engineer

• Fully inclusive of warranty and breakdown

cover
• 24/7 regional service support

• Remote diagnostics support

• Unrivalled industry experience


• Legislation compliant service

documentation

• Regional on-call service engineer 24/7


• EN14181 compliant functional checks

• Comprehensive stockists of critical spare

parts and consumables

•  egional service structure
R
•  edicated engineers allocated to your site
D
to improve customer relations and quality of
service
•  ost experienced CEMS service team in the
M
UK with combined industry experience of over
150 years

Paul Morgan
Southern Area Sales 
Service Manager

Training:
a1-cbiss can provide a comprehensive training
package to meet all of your site requirements. Our
service department can also provide full system
training for your staff, advice and support for OMA
surveys and advice and guidance on all relevant
legislation. We offer structured training programs for
all of our CEMS equipment, which would comprise of
the following topics:
• Advanced system technical training
• Advanced system CDAS training
•  bjective CEMS specification consultancy to meet
O
permit requirements
• Legislation specific
• EN14181 - QAL3

13

Tel: 0151 666 8300
www.a1-cbiss.com

14
Client Reference Lists

Client Testimonials

Veolia, Ellesmere Port

Peake GB Ltd, Cornwall

Dalkia, Chilton

MES, Wolverhampton

“
	

W
 e became aware of a1-cbiss and their emissions monitoring systems through our
operational involvement on one of our Contract Energy Management contracts in the NorthEast of England.

	 were in the design phase of a new wood chip burning Power Station and, as relative
We
newcomers to this field, we received a great deal of technical guidance from a1-cbiss
regarding WID compliance.

London Waste, Edmonton

MES, Dudley,

CNIM, States of Jersey

MES, Stoke

Inco Europe, London

Veolia SELCHP Deptford
,

	

We look forward to working with them during the commissioning phase of the station.

Voelia, Tyseley

Metso, Markinch Scotland

	
	
	

Peter Cleary
Senior Project Engineer
Dalkia Energy

Hampshire Waste, Chineham

Slough Heat  Power Ltd

Hampshire Waste, Marchwood

EON UK Ltd, Ironbridge

Hampshire Waste, Portsmouth

EON UK Ltd, Kingsnorth

Qinetiq Ltd, Essex

EON UK Ltd, Castleford

Coventry  Solihull

EON UK Ltd, Killingholme

	 were particularly impressed by the fact that the CEMS is 100% engineered by a1-cbiss
We
including the CDAS software and also received a very competitive tender return compared to
their rivals in this field.

“
“

”

”

EON UK Ltd, Sandbach

Whiterose Environmental Ltd, Kent

Coryton Power, Stanford-le-hope

DSTL, Wiltshire

EON UK Ltd, Stoke on Trent

Lakeside EFW, Colnbrook

EON UK Ltd, Ratcliffe

Grundon Waste Management Ltd, Berkshire

15

Tel: 0151 666 8300
www.a1-cbiss.com

W
 SP regularly partner with a1-cbiss to ensure our permitting clients get the best technical
advice and response to their CEMS needs.

	
	
	

Neal Barker
Technical Director
WSP Environment and Energy

	

Borders General Hospital, Melrose

	

W
 e have been using a1-cbiss since the plant was built for their expertise, technical
guidance and market leading equipment. The equipment we have onsite is the MIR-FT
system combined with a GR52M FID and the a1-cbiss data acquisition software CDAS
Elite. The complete CEM system has proven to be very reliable and dependable over the
years. One of the key benefits to us is the CDAS elite software package which is easy to
use and extremely flexible meeting all our site requirements. The a1-cbiss engineers offer
exceptional support, as well as being professional and knowledgeable. The a1-cbiss
legislative consultancy approach has been invaluable and helped contribute to us achieving
one of the highest OMA scores in the industry.

	
	
	

Andy McQueen
EFW Facility Plant Manager
Veolia Chineham

”

16
Case Study
Power Industry

the Result
a1-cbiss manage all aspects of the project from design  build, installation and commissioning, through to on-going
service and support.

the Background
Because of ageing equipment and increasing issues surrounding reliability, one of Europe’s leading power suppliers
decided to roll out a series of site upgrades to replace their continuous emission monitoring systems (CEMS) at a coal
fired power station and two gas turbine sites across the UK.

The coal fired power station saw the installation of nine MIR9000 multi-gas MCERTS accredited analysers comprising
of four duty MIR9000 systems and 1 standby MIR9000 with a changeover system for redundancy. The analysers are
integrated into a purpose built enclosure, all communicating via the MCERTS certified CBISS Elite Data Acquisition 
Reporting software (CDAS) which also incorporates the IVIS hardware panel allowing for QAL 3 functionality.
The gas turbine site saw the installation of seven MIR9000 CLD multi-gas analysers. Again the analysers are integrated
into a purpose built enclosure, all communicating via the MCERTS certified CBISS Elite Data Acquisition  Reporting
software (CDAS) which also incorporates the IVIS hardware panel allowing for QAL 3 functionality.

the Challenge
1.  o supply CEMS that complies with the requirements of MCERTS, the large combustion plant directive (LCPD) and the
T
industrial emissions directive (IED), which is due to be enforced in 2016
2. To include a system redundancy option at the coal fired power station to prevent any downtime

Design and Build

3.  o monitor temperature, pressure and flow measurement directly from the flue and establish communications between
T
the analysers and Data Acquisition  Reporting Software
4.  he coal fired power station required the systems to be installed in the main exit flues (within one concrete windshield),
T
at a height of 75 meters above ground level
5.  he incumbent systems were not provided by a1-cbiss, therefore a1-cbiss would have to prove that their solution,
T
service and support is superior to the incumbent supplier

Purpose Built Enclosure

the Solution
At the coal fired power station, a1-cbiss proposed an MCERTS accredited MIR9000 infrared multi-gas analyser that
monitors extracted samples on a dry basis, using a SEC sample conditioning system. The SEC sample conditioning
system comprised of an in-situ probe, a permeation dryer unit and a temperature, pressure and flow module
integrated into the same probe. A permeation dryer eradicates the requirement for long lengths of heated line.
The MIR9000 system MCERTS accreditation is based on the Emission Limit Values (ELV) of the waste incineration
directive, and subsequently future proofs the site for the ELV change when the IED comes into force in 2016.
Using a single probe for measuring all of the required parameters reduced the number of penetrations in the flues and
consequently lowered the cost of installation.
The option for system redundancy was addressed by proposing a fully automated change-over system with an additional
MIR9000 analyser. The system would be fully controlled by the CDAS software, therefore requiring minimal user
intervention and eliminating any risk of downtime.
For the gas turbine site, a1-cbiss proposed MIR9000 CLD chemiluminescence and infrared multi-gas analysers that
monitor extracted samples on a dry basis, using a SEC sample conditioning system. The SEC sample conditioning system
comprised of the same elements as used in the MIR9000 system. The CLD system fully complies with the standard
reference method (SRM) EN 14792 for the measurement of NOx. The CLD also has MCERTS certification that complies
with the new limits in the IED.

Installation  Commissioning

Service  support is integral to the a1-cbiss offering. With the largest service network in the industry and nationwide
coverage, the dedicated team of service engineers provide service, repair  maintenance on all equipment supplied.

17

Tel: 0151 666 8300
www.a1-cbiss.com

18

Contenu connexe

Tendances (14)

Inspecting Lead-Clad Pipes with Pulsed Eddy Current (PEC)
Inspecting Lead-Clad Pipes with Pulsed Eddy Current (PEC)Inspecting Lead-Clad Pipes with Pulsed Eddy Current (PEC)
Inspecting Lead-Clad Pipes with Pulsed Eddy Current (PEC)
 
Gas detection
Gas detectionGas detection
Gas detection
 
Estimation of Pressure Drop in Pipe Systems
Estimation of Pressure Drop in Pipe SystemsEstimation of Pressure Drop in Pipe Systems
Estimation of Pressure Drop in Pipe Systems
 
Acoustic Emission testing
Acoustic Emission testingAcoustic Emission testing
Acoustic Emission testing
 
Ultrasonic Testing Level 1 Quiz
Ultrasonic Testing Level 1 QuizUltrasonic Testing Level 1 Quiz
Ultrasonic Testing Level 1 Quiz
 
Measure uncertainty
Measure uncertaintyMeasure uncertainty
Measure uncertainty
 
UT _ Ultrasonic Testing
UT _ Ultrasonic TestingUT _ Ultrasonic Testing
UT _ Ultrasonic Testing
 
A review of the application of Acoustic Emission Technique in Engineering
A review of the application of Acoustic Emission Technique in EngineeringA review of the application of Acoustic Emission Technique in Engineering
A review of the application of Acoustic Emission Technique in Engineering
 
4.4.heat exchanger
4.4.heat exchanger4.4.heat exchanger
4.4.heat exchanger
 
Introduction to Fiscal Metering (Custody Transfer)
Introduction to Fiscal Metering (Custody Transfer) Introduction to Fiscal Metering (Custody Transfer)
Introduction to Fiscal Metering (Custody Transfer)
 
Indoor Air Quality for School Buildings
Indoor Air Quality for School BuildingsIndoor Air Quality for School Buildings
Indoor Air Quality for School Buildings
 
ipec.info | Pfd p&id
ipec.info | Pfd p&idipec.info | Pfd p&id
ipec.info | Pfd p&id
 
TTTech Company Overview
TTTech Company OverviewTTTech Company Overview
TTTech Company Overview
 
Asme b 36.19
Asme b 36.19Asme b 36.19
Asme b 36.19
 

Similaire à Continuous Emissions Monitoring

GCEM 40 series extractive gas analyser codel datasheet
GCEM 40 series extractive gas analyser codel datasheetGCEM 40 series extractive gas analyser codel datasheet
GCEM 40 series extractive gas analyser codel datasheetENVIMART
 
Hệ thống quan trắc khí thải tự động - Tư vấn: 0938-564-123
Hệ thống quan trắc khí thải tự động - Tư vấn: 0938-564-123Hệ thống quan trắc khí thải tự động - Tư vấn: 0938-564-123
Hệ thống quan trắc khí thải tự động - Tư vấn: 0938-564-123Lâm Nguyễn Hoàng
 
GCEM4100 extractive gas analyser codel datasheet
GCEM4100 extractive gas analyser codel datasheetGCEM4100 extractive gas analyser codel datasheet
GCEM4100 extractive gas analyser codel datasheetENVIMART
 
GCEM4000 insitu gas analyser codel datasheet
GCEM4000 insitu gas analyser codel datasheetGCEM4000 insitu gas analyser codel datasheet
GCEM4000 insitu gas analyser codel datasheetENVIMART
 
Steri trac detection system 0
Steri trac detection system 0Steri trac detection system 0
Steri trac detection system 0a1-cbiss
 
Mir ft datasheet
Mir ft datasheetMir ft datasheet
Mir ft datasheeta1-cbiss
 
Refrigeration brochure sept 2012 (2)
Refrigeration brochure sept 2012 (2)Refrigeration brochure sept 2012 (2)
Refrigeration brochure sept 2012 (2)a1-cbiss
 
GCEM 40 series gas analyser insitu-codel datasheet
GCEM 40 series gas analyser insitu-codel datasheetGCEM 40 series gas analyser insitu-codel datasheet
GCEM 40 series gas analyser insitu-codel datasheetENVIMART
 
Sensepoint_Pro_pdf.pdf
Sensepoint_Pro_pdf.pdfSensepoint_Pro_pdf.pdf
Sensepoint_Pro_pdf.pdfssuser3e1ce9
 
Data sheet g52 m print version
Data sheet g52 m print versionData sheet g52 m print version
Data sheet g52 m print versiona1-cbiss
 
Mir is datasheet
Mir is datasheetMir is datasheet
Mir is datasheeta1-cbiss
 
Refrigeration Brochure
Refrigeration BrochureRefrigeration Brochure
Refrigeration Brochurea1-cbiss
 
Refrigeration brochure 3
Refrigeration brochure 3Refrigeration brochure 3
Refrigeration brochure 3a1-cbiss
 
Rotronic Katalog 2017 | Rotronic measuring instruments and monitoring solutions
Rotronic Katalog 2017 | Rotronic measuring instruments and monitoring solutionsRotronic Katalog 2017 | Rotronic measuring instruments and monitoring solutions
Rotronic Katalog 2017 | Rotronic measuring instruments and monitoring solutionsPT. Siwali Swantika
 
Crowcon Portable Gas Detectors - Product Brochure
Crowcon Portable Gas Detectors - Product BrochureCrowcon Portable Gas Detectors - Product Brochure
Crowcon Portable Gas Detectors - Product BrochureThorne & Derrick UK
 

Similaire à Continuous Emissions Monitoring (20)

GCEM 40 series extractive gas analyser codel datasheet
GCEM 40 series extractive gas analyser codel datasheetGCEM 40 series extractive gas analyser codel datasheet
GCEM 40 series extractive gas analyser codel datasheet
 
Hệ thống quan trắc khí thải tự động - Tư vấn: 0938-564-123
Hệ thống quan trắc khí thải tự động - Tư vấn: 0938-564-123Hệ thống quan trắc khí thải tự động - Tư vấn: 0938-564-123
Hệ thống quan trắc khí thải tự động - Tư vấn: 0938-564-123
 
GCEM4100 extractive gas analyser codel datasheet
GCEM4100 extractive gas analyser codel datasheetGCEM4100 extractive gas analyser codel datasheet
GCEM4100 extractive gas analyser codel datasheet
 
GCEM4000 insitu gas analyser codel datasheet
GCEM4000 insitu gas analyser codel datasheetGCEM4000 insitu gas analyser codel datasheet
GCEM4000 insitu gas analyser codel datasheet
 
Steri trac detection system 0
Steri trac detection system 0Steri trac detection system 0
Steri trac detection system 0
 
Mir ft datasheet
Mir ft datasheetMir ft datasheet
Mir ft datasheet
 
Refrigeration brochure sept 2012 (2)
Refrigeration brochure sept 2012 (2)Refrigeration brochure sept 2012 (2)
Refrigeration brochure sept 2012 (2)
 
GCEM 40 series gas analyser insitu-codel datasheet
GCEM 40 series gas analyser insitu-codel datasheetGCEM 40 series gas analyser insitu-codel datasheet
GCEM 40 series gas analyser insitu-codel datasheet
 
Sensepoint_Pro_pdf.pdf
Sensepoint_Pro_pdf.pdfSensepoint_Pro_pdf.pdf
Sensepoint_Pro_pdf.pdf
 
Data sheet g52 m print version
Data sheet g52 m print versionData sheet g52 m print version
Data sheet g52 m print version
 
Dissolved Oxygen Sensors-Oxymax COS22/22D
Dissolved Oxygen Sensors-Oxymax COS22/22DDissolved Oxygen Sensors-Oxymax COS22/22D
Dissolved Oxygen Sensors-Oxymax COS22/22D
 
Mir is datasheet
Mir is datasheetMir is datasheet
Mir is datasheet
 
Refrigeration Brochure
Refrigeration BrochureRefrigeration Brochure
Refrigeration Brochure
 
KwikSense Smart Digital Gas Transmitter
KwikSense Smart Digital Gas TransmitterKwikSense Smart Digital Gas Transmitter
KwikSense Smart Digital Gas Transmitter
 
Refrigeration brochure 3
Refrigeration brochure 3Refrigeration brochure 3
Refrigeration brochure 3
 
Photometric sensor for SAC or nitrate measurement
Photometric sensor for SAC or nitrate measurementPhotometric sensor for SAC or nitrate measurement
Photometric sensor for SAC or nitrate measurement
 
Rotronic Katalog 2017 | Rotronic measuring instruments and monitoring solutions
Rotronic Katalog 2017 | Rotronic measuring instruments and monitoring solutionsRotronic Katalog 2017 | Rotronic measuring instruments and monitoring solutions
Rotronic Katalog 2017 | Rotronic measuring instruments and monitoring solutions
 
Crowcon Portable Gas Detectors Product Brochure
Crowcon Portable Gas Detectors Product BrochureCrowcon Portable Gas Detectors Product Brochure
Crowcon Portable Gas Detectors Product Brochure
 
Crowcon Portable Gas Detectors - Product Brochure
Crowcon Portable Gas Detectors - Product BrochureCrowcon Portable Gas Detectors - Product Brochure
Crowcon Portable Gas Detectors - Product Brochure
 
CEMSI Cement Solutions
CEMSI Cement SolutionsCEMSI Cement Solutions
CEMSI Cement Solutions
 

Plus de a1-cbiss

Gas Detector Tube List
Gas Detector Tube ListGas Detector Tube List
Gas Detector Tube Lista1-cbiss
 
a1-cbiss Gas Detectors Brochure
a1-cbiss Gas Detectors Brochurea1-cbiss Gas Detectors Brochure
a1-cbiss Gas Detectors Brochurea1-cbiss
 
a1-cbiss Gastec Tubes
a1-cbiss Gastec Tubesa1-cbiss Gastec Tubes
a1-cbiss Gastec Tubesa1-cbiss
 
Tango tx1 Gas Detection Datasheet
Tango tx1 Gas Detection DatasheetTango tx1 Gas Detection Datasheet
Tango tx1 Gas Detection Datasheeta1-cbiss
 
Oldham OLCT100 Gas Detector Datasheet
Oldham OLCT100 Gas Detector DatasheetOldham OLCT100 Gas Detector Datasheet
Oldham OLCT100 Gas Detector Datasheeta1-cbiss
 
Mx43 Gas Detector
Mx43 Gas DetectorMx43 Gas Detector
Mx43 Gas Detectora1-cbiss
 
Innova 1412 Gas Monitor
Innova 1412 Gas MonitorInnova 1412 Gas Monitor
Innova 1412 Gas Monitora1-cbiss
 
Oldham OLCT80 Gas Detector
Oldham OLCT80 Gas DetectorOldham OLCT80 Gas Detector
Oldham OLCT80 Gas Detectora1-cbiss
 
MSA Ultrasonic Gas Detector
MSA Ultrasonic Gas DetectorMSA Ultrasonic Gas Detector
MSA Ultrasonic Gas Detectora1-cbiss
 
Odalog RTx Datasheet
Odalog RTx DatasheetOdalog RTx Datasheet
Odalog RTx Datasheeta1-cbiss
 
Egas datasheet
Egas datasheetEgas datasheet
Egas datasheeta1-cbiss
 
Horiba pg250 datasheet
Horiba pg250 datasheetHoriba pg250 datasheet
Horiba pg250 datasheeta1-cbiss
 
Olct10 datasheet
Olct10 datasheetOlct10 datasheet
Olct10 datasheeta1-cbiss
 
Wireless olct 80 datasheet 0
Wireless olct 80 datasheet 0Wireless olct 80 datasheet 0
Wireless olct 80 datasheet 0a1-cbiss
 
Monicon ir80 co2 gas detector
Monicon ir80 co2 gas detectorMonicon ir80 co2 gas detector
Monicon ir80 co2 gas detectora1-cbiss
 
Detect f 2013 datasheet 0
Detect f 2013 datasheet 0Detect f 2013 datasheet 0
Detect f 2013 datasheet 0a1-cbiss
 
Genie 757 spot sampling assembly datasheet
Genie 757 spot sampling assembly datasheetGenie 757 spot sampling assembly datasheet
Genie 757 spot sampling assembly datasheeta1-cbiss
 
Oda log l2 datasheet
Oda log l2 datasheetOda log l2 datasheet
Oda log l2 datasheeta1-cbiss
 
Gas badge pro datasheet
Gas badge pro datasheetGas badge pro datasheet
Gas badge pro datasheeta1-cbiss
 
Qal 991 particulate monitor datasheet
Qal 991 particulate monitor datasheetQal 991 particulate monitor datasheet
Qal 991 particulate monitor datasheeta1-cbiss
 

Plus de a1-cbiss (20)

Gas Detector Tube List
Gas Detector Tube ListGas Detector Tube List
Gas Detector Tube List
 
a1-cbiss Gas Detectors Brochure
a1-cbiss Gas Detectors Brochurea1-cbiss Gas Detectors Brochure
a1-cbiss Gas Detectors Brochure
 
a1-cbiss Gastec Tubes
a1-cbiss Gastec Tubesa1-cbiss Gastec Tubes
a1-cbiss Gastec Tubes
 
Tango tx1 Gas Detection Datasheet
Tango tx1 Gas Detection DatasheetTango tx1 Gas Detection Datasheet
Tango tx1 Gas Detection Datasheet
 
Oldham OLCT100 Gas Detector Datasheet
Oldham OLCT100 Gas Detector DatasheetOldham OLCT100 Gas Detector Datasheet
Oldham OLCT100 Gas Detector Datasheet
 
Mx43 Gas Detector
Mx43 Gas DetectorMx43 Gas Detector
Mx43 Gas Detector
 
Innova 1412 Gas Monitor
Innova 1412 Gas MonitorInnova 1412 Gas Monitor
Innova 1412 Gas Monitor
 
Oldham OLCT80 Gas Detector
Oldham OLCT80 Gas DetectorOldham OLCT80 Gas Detector
Oldham OLCT80 Gas Detector
 
MSA Ultrasonic Gas Detector
MSA Ultrasonic Gas DetectorMSA Ultrasonic Gas Detector
MSA Ultrasonic Gas Detector
 
Odalog RTx Datasheet
Odalog RTx DatasheetOdalog RTx Datasheet
Odalog RTx Datasheet
 
Egas datasheet
Egas datasheetEgas datasheet
Egas datasheet
 
Horiba pg250 datasheet
Horiba pg250 datasheetHoriba pg250 datasheet
Horiba pg250 datasheet
 
Olct10 datasheet
Olct10 datasheetOlct10 datasheet
Olct10 datasheet
 
Wireless olct 80 datasheet 0
Wireless olct 80 datasheet 0Wireless olct 80 datasheet 0
Wireless olct 80 datasheet 0
 
Monicon ir80 co2 gas detector
Monicon ir80 co2 gas detectorMonicon ir80 co2 gas detector
Monicon ir80 co2 gas detector
 
Detect f 2013 datasheet 0
Detect f 2013 datasheet 0Detect f 2013 datasheet 0
Detect f 2013 datasheet 0
 
Genie 757 spot sampling assembly datasheet
Genie 757 spot sampling assembly datasheetGenie 757 spot sampling assembly datasheet
Genie 757 spot sampling assembly datasheet
 
Oda log l2 datasheet
Oda log l2 datasheetOda log l2 datasheet
Oda log l2 datasheet
 
Gas badge pro datasheet
Gas badge pro datasheetGas badge pro datasheet
Gas badge pro datasheet
 
Qal 991 particulate monitor datasheet
Qal 991 particulate monitor datasheetQal 991 particulate monitor datasheet
Qal 991 particulate monitor datasheet
 

Dernier

FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024The Digital Insurer
 
Boost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfBoost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfsudhanshuwaghmare1
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...Martijn de Jong
 
ICT role in 21st century education and its challenges
ICT role in 21st century education and its challengesICT role in 21st century education and its challenges
ICT role in 21st century education and its challengesrafiqahmad00786416
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processorsdebabhi2
 
Spring Boot vs Quarkus the ultimate battle - DevoxxUK
Spring Boot vs Quarkus the ultimate battle - DevoxxUKSpring Boot vs Quarkus the ultimate battle - DevoxxUK
Spring Boot vs Quarkus the ultimate battle - DevoxxUKJago de Vreede
 
CNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In PakistanCNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In Pakistandanishmna97
 
Why Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businessWhy Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businesspanagenda
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoffsammart93
 
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...DianaGray10
 
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProduct Anonymous
 
[BuildWithAI] Introduction to Gemini.pdf
[BuildWithAI] Introduction to Gemini.pdf[BuildWithAI] Introduction to Gemini.pdf
[BuildWithAI] Introduction to Gemini.pdfSandro Moreira
 
MINDCTI Revenue Release Quarter One 2024
MINDCTI Revenue Release Quarter One 2024MINDCTI Revenue Release Quarter One 2024
MINDCTI Revenue Release Quarter One 2024MIND CTI
 
Cyberprint. Dark Pink Apt Group [EN].pdf
Cyberprint. Dark Pink Apt Group [EN].pdfCyberprint. Dark Pink Apt Group [EN].pdf
Cyberprint. Dark Pink Apt Group [EN].pdfOverkill Security
 
Ransomware_Q4_2023. The report. [EN].pdf
Ransomware_Q4_2023. The report. [EN].pdfRansomware_Q4_2023. The report. [EN].pdf
Ransomware_Q4_2023. The report. [EN].pdfOverkill Security
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerThousandEyes
 
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWEREMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWERMadyBayot
 
Artificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : UncertaintyArtificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : UncertaintyKhushali Kathiriya
 
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost SavingRepurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost SavingEdi Saputra
 

Dernier (20)

FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024
 
Boost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfBoost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdf
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...
 
ICT role in 21st century education and its challenges
ICT role in 21st century education and its challengesICT role in 21st century education and its challenges
ICT role in 21st century education and its challenges
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processors
 
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
 
Spring Boot vs Quarkus the ultimate battle - DevoxxUK
Spring Boot vs Quarkus the ultimate battle - DevoxxUKSpring Boot vs Quarkus the ultimate battle - DevoxxUK
Spring Boot vs Quarkus the ultimate battle - DevoxxUK
 
CNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In PakistanCNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In Pakistan
 
Why Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businessWhy Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire business
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
 
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
 
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
 
[BuildWithAI] Introduction to Gemini.pdf
[BuildWithAI] Introduction to Gemini.pdf[BuildWithAI] Introduction to Gemini.pdf
[BuildWithAI] Introduction to Gemini.pdf
 
MINDCTI Revenue Release Quarter One 2024
MINDCTI Revenue Release Quarter One 2024MINDCTI Revenue Release Quarter One 2024
MINDCTI Revenue Release Quarter One 2024
 
Cyberprint. Dark Pink Apt Group [EN].pdf
Cyberprint. Dark Pink Apt Group [EN].pdfCyberprint. Dark Pink Apt Group [EN].pdf
Cyberprint. Dark Pink Apt Group [EN].pdf
 
Ransomware_Q4_2023. The report. [EN].pdf
Ransomware_Q4_2023. The report. [EN].pdfRansomware_Q4_2023. The report. [EN].pdf
Ransomware_Q4_2023. The report. [EN].pdf
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected Worker
 
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWEREMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
 
Artificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : UncertaintyArtificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : Uncertainty
 
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost SavingRepurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
 

Continuous Emissions Monitoring

  • 1. Contact Us: North & Scotland Area Sales & Service Manager Sam Thorneycroft Mobile: 07771 640245 Email: sam.thorneycroft@a1-cbiss.com Southern Area Sales & Service Manager Paul Morgan Mobile: 07909 992517 Email: paul.morgan@a1-cbiss.com Head Office, Engineering & Service a1-cbiss Ltd 11 Ark Royal Way Lairdside Technology Park Tranmere Wirral CH41 9HT Web: www.a1-cbiss.com General Tel: +44 (0) 151 666 8300 Service & Engineering Fax: +44 (0) 151 666 8566 Accounts, Sales & General Fax: +44 (0) 151 666 8329 Email: engineering@a1-cbiss.com Continuous Emission Monitoring Systems service@a1-cbiss.com sales@a1-cbiss.com Market Leading Technical & Legislative Consultancy Complete Turnkey Solution Providers MCERTS Accredited Hardware & Software Cradle to Grave Support Approach
  • 2. Continuous Emission Monitoring Systems For over 20 years, a1-cbiss continue to be a market leading • MCERTS accredited emission monitoring systems provider • pecialising in design, manufacture and integration S For over a decade, a1-cbiss have built a relationship with Environnement SA to provide a range of MCERTS accredited, market leading Continuous Emission Monitoring Systems to meet your legislative requirements • omplete environmental monitoring turnkey C solutions • ully MCERTS accredited Data Acquisition F Software • upported by the industry’s largest service S network across the UK 2. Dedicated Project Management • very project is fully supported by a E dedicated project manager to provide one point of contact throughout every phase through to completion 1. CEMS Management Consultancy • arket leading technical legislative M consultancy • omplete turnkey solution providers C • radle to grave support C approach 3. n-House Project Design, I Build Integration • egular design reviews R client feedback support revisions as the project evolves • ystems are all custom S built in-house by factory trained engineers • actory Acceptance F Tests (FAT’s) carried out with all relevant inspection certification issued 5. After Sales Service Support • Bespoke contracts tailored to site specific, legislative or budgetary requirements offering peace of mind that equipment is covered for all eventualities • 24/7 regional service support • From 6 hour callout response 1 Tel: 0151 666 8300 www.a1-cbiss.com 4. Installation Commissioning • xpert installation team with over 10 years experience to E integrate, calibrate commission your system • Site Acceptance Tests (SAT’s) carried out 2
  • 3. Environnement SA MIR-FT Environnement SA MIR-9000 (Plus CLD Option) Fourier Transform Infra-Red Datasheet Multi-Gas Infrared GFC Analyser Datasheet Installed across the majority of the UK’s municipal waste incinerators, the MIR-FT Utilises Fourier Transform Infra-Red (FT-IR) to offer multiple gas measurements simultaneously, including NO, NO2, SO2, NH3, HCl and CO. With the emissions limits tightening and new gases being introduced, this instrument allows future gas upgrades, providing the solution for today and what may happen tomorrow. Designed to operate under legislation such as 2000/76/EC (WID) and 2001/80/EC (LCPD), The MIR-FT offers maximum availability and complete compliance with QAL 1 of EN14181 EN15267-3. The MIR-FT is rack mounted in air conditioned enclosures. Complete systems would normally comprise of: • ample extraction and conditioning probe (with integrated S temperature, pressure and flow measurement) • eated sample lines H • utomatic calibration units A • nstrument air drying system I • DAS Data Acquisition Software C Features: • esigned for measurements in wet and corrosive sample D gases • Future upgrades possible • Excellent calibration stability • Automatic spectral interference corrections • Fast and simultaneous measurements for multiple gases • Reproducible and accurate • Windows based PC driven software with on-board data acquisition • Capable of automatic QAL 3 checks when used in conjuction with IVIS unit • MCERTS Certified With over 1500 installations world wide, the MIR-9000 is a proven Continuous Emissions Monitoring system across a wide range of industries. All measurements are supplied dry as the sample is conditioned at the extraction point via the SEC drying system before being transported down a cool polytube line. The MIR-9000-CLD option utilises the Standard Reference Method (SRM) for the monitoring of NO N2O NO2 NOx CO CO2 SO2 and O2. The MIR-9000-CLD analyser is a free standing monitoring system that incorporates three monitoring technologies, these are Chemiluminescence for low level NOx measurement, Infra-Red Gas Filter Correlation for CO, CO2 etc and finally Paramagnetic for O2. Designed to operate under legislation such as 2000/76/EC (WID) and 2001/80/EC (LCPD), The MIR-9000 offers maximum availability and complete compliance with QAL 1 of EN14181 EN15267-3. Features: • Measures from 1 - 10 gases simultaneously • Built-in data logger for 7 additional parameters (flow, pressure, temperature or any other analogue input) Complete systems would normally comprise of: • Real time graphic display • Sample extraction and conditioning probe (with integrated temperature, pressure and flow measurement) • Interactive menu-driven software allowing ease of operation • Cold sample lines • Readings measured and expressed on a dry basis • Unheated sample line utilising permapure drying technology • On-board oxygen correction for environmental reporting • Automatic calibration units • Instrument air drying system • Optional stack pressure, temperature and flow measurements available • DAS Data Acquisition Software C • MCERTS Certified Specification Specification Applications: • Municipal, Industrial Hospital Waste Incinerators • Power Combustion • Biomass • Cement Kilns • Pulp Paper • DeNOx (SNCR, SCR) 3 Specification: Z ero drift: ± 1% full scale/30 days Span drift: ± 1% full scale/30 days Repeatability: ± 2% full scale Lower detectable limit: 2% full scale Response time: 2mins depending on the gas Power supply: 220V, ± 15%, 50-60Hz, 200VA Weight: 20 kg approximately Operating temperature: +10°C to +35°C Tel: 0151 666 8300 www.a1-cbiss.com Applications: Gas NO NO2 CO CO2 SO2 N2O HCl NH3 H2O O2 MCERTS Certification Ranges 0-200mg/m3 - 0-600mg/m3 0-200mg/m3 0-75mg/m3 - 0-300mg/m3 0-25% 0-75mg/m3 - 0-500mg/m3 0-100mg/m3 0-15mg/m3 - 0-90mg/m3 0-15mg/m3 0-30% 0-25% Specification: • Municipal, Industrial Hospital Waste Incinerators Repeatability: 2% of Full Scale (F.S.) • Thermal Oxidisers • Exhaust Gas Analysis • tandard Reference Method for VOC S Monitoring • Laboratories and Research Centres • Process Control • Combustion Monitoring Zero drift: 2% F.S. / 30 days Span drift: 1% F.S. / 7 days Linearity: 1% F.S. Power supply: 80 - 230V, 50-60 Hz Consumption: 300 VA Serial link: RS232, RS422 Operating temperature: +5°C to +40°C Gas MCERTS Certification Ranges NO (CLD) 0-20mg/m3 - 0-2000mg/m3 NO2 (CLD) 0-20mg/m3 NOx (CLD) 0-20mg/m3 NO 0-100mg/m3 - 0-500mg/m3 CO 0-75mg/m3 - 0-500mg/m3 CO2 0-25% SO2 0-75mg/m3 - 0-200mg/m3 N2O 0-20mg/m3 - 0-200mg/m3 HCl 0-15mg/m3 - 0-100mg/m3 CH4 0-10mg/m3 - 0-200mg/m3 O2 0-10% - 0-25% 4
  • 4. Environnement SA Graphite 52M Environnement SA MIR-IS Infra-Red Gas Filter Correlation Datasheet Heated FID Volatile Organic Compounds Analyser Datasheet Designed to operate under legislation such as 2000/76/ EC (WID) and 2001/80/EC (LCPD), The MIR-IS offers maximum availability and complete compliance with QAL 1 of EN14181 EN15267-3. Based on the MIR-9000, the in-situ multi-gas CEM system is a compact extractive monitoring system, providing fast response, close coupled measurements. For multi-gas monitoring, in less than 40 milliseconds, the MIR-IS monitors each selected gas by Infra-Red Gas Filter Correlation principle. This technology eliminates cross sensitivity from other present gases and provides high accuracy. The MIR-IS also monitors temperature, flow and pressure integrated into the sample extraction probe. Features: • n-situ extractive installation I • Measures from 1-10 gases simultaneously • ase of installation: single stack entry, sample line not E required therefore reducing costs • ntegrated air drying and handling system I • he Infra-red technology eliminates cross sensitivity from T other present gases and provides high accuracy • ast response for process control F • uto calibration check capability A • owerful remote functions P • ynoptic flow diagram display S • nteractive menu driven software I • ptional stack pressure, temperature and flow O measurements available • CERTS Certified M The FID is temperature controlled up to 191°C to eliminate condensation. Extremely compact and with a very short response time, this heated FID provides continuous monitoring of total VOC’s, in compliance with the Waste Incineration Directive and EN12619 standard as written in most WID permits. The Graphite 52M is fully supported by MCERTS certified CDAS Elite Data Aquisition Software and a comprehensive service and support package. Equipped with one burner placed in a heated block, the Graphite 52M allows continuous and accurate Total VOC monitoring. Specification Specification Applications: • Municipal, Industrial Hospital Waste Incinerators • Power Combustion • Biomass • Cement Kilns • Pulp Paper • DeNOx (SNCR, SCR) 5 Specification: • aterial in contact with effluent: M Stainless Steel, Hastelloy or PTFE • umber of gases monitored: up to 10 N • epeatability: ± 2% of full scale R • ero drift: ± 2% of full scale/30 days Z • pan drift: ± 2% of full scale/30 days S • inearity: ± 1% of full scale L • owest detectable limit: ± 2% of full L scale • ata storage: last 3000 averages D • igital output: RS232/422 D • robe length: 700x1000x1500mm P • eight: 30kg approximately W • ower: 115/230VAC, 50/60Hz, 700VA P • perating temperature: -15°C to O +50°C Tel: 0151 666 8300 www.a1-cbiss.com Gas NO N2O CO CO2 SO2 HCl CH4 O2 MCERTS Certification Ranges 0-100mg/m3 - 0-500mg/m3 0-20mg/m3 - 0-200mg/m3 0-75mg/m3 - 0-500mg/m3 0-25% 0-75mg/m3 - 0-200mg/m3 0-15mg/m3 - 0-100mg/m3 0-10mg/m3 - 0-200mg/m3 0-10% - 0-25% Features: • Detector placed in a heated oven, up to 191°C allowing measurement of high concentrations of heavy hydrocarbons • Fast response time • Real time graphic display with interactive menu driven software • Integrated zero air catalyst • Dual stream monitoring by independent detectors available • User selectable ranging • Very low limits of detection • Hydrogen/Helium fuel supply thus reducing oxygen interference • Fully compatible with the Environnement S.A. MIR-FT MIR-9000 CEM systems • MCERTS Certified Applications: • Municipal, Industrial Hospital Waste Incinerators • Thermal Oxidisers • Exhaust Gas Analysis • Standard Reference Method for VOC Monitoring • Laboratories and Research Centres • Process Control • Combustion Monitoring MCERTS Certification Range: TOC: 0-15mg/m3 Specification: • anges: 0-10/100/1000/10000 ppm or user programmable R range up to 50 000 ppm • ccuracy: 1% of the displayed value between 15% and A 100% of the F.S. • ower detectable limit: 0.05 ppm of the 10 ppm range L • esponse time: 1 sec. (T90) R • ero drift: 1%/24h F.S. 2%/7 days F.S. Z • pan drift: 1% / 7 days F.S. S • inearity: 1% for concentration between 10 % and 90% L of the scale • emperature of the heated block: up to 191°C T • eight: 22kg approximately W • Power supply: 230 VAC, 50Hz or 115 VAC, 60 Hz • Operating temperature: +5°C to +40°C 6
  • 5. Syngas Monitoring System PCME QAL181 QAL991 Particulate Monitoring Systems Datasheet Datasheet The PCME QAL181 utilises Proscatter to measure the scattered forward light from a laser source. The QAL991 utilises PCME’s unique AC Electrodynamic technology, an advanced Triboelectric method. Syngas Monitoring System (SMS) is designed to monitor and report the constituents of the syngas produced by the gasification process. The SMS provides live CV value, essential to determine your qualification for renewable obligation certificates (ROCS). In modern gasification where syngas composition is paramount for determining the calorific value, the a1-cbiss SMS provides an accurate, cost effective solution. The QAL181 QAL991 are ideal where high accuracy and stability are required or when bag filters are not installed, designed to operate under legislation such as 2000/76/EC (WID) and 2001/80/EC (LCPD), the QAL181 offers complete compliance with EN14181, EN13284-2 EN15267-3. The SMS utilises varying degrees of high temperature probes ranging from stainless steel through to inconel and water cooled if required. The SMS gas is continuously taken, conditioned and analysed at a single sampling point. Features: • Automatic self-checks which record results for QAL3 tests Sample preparation and conditioning is a key element of the system, upon which substantially depends on the correctness of the consequent measurement, as well as the lifetime of the measurement sensors. • Capability to conduct linearity checks in accordance with EN14181 • Real time graphic display with interactive menu driven software • Very low limits of detection With online calibration capability, the QAL181 QAL991 minimises drift but also offers the QAL3 facility when used with CDAS Elite Data Acquisition Software. Specification • MCERTS Certified Specification Applications: Specification QAL991 Specification QAL181 • Municipal, Industrial Hospital Waste Incinerators • ertification range: 0-15mg/m3 (as C stated in QAL1 approval) • Thermal Oxidisers • easurement capability: 0-100mg/m3 M • Exhaust Gas Analysis • ong term zero drift: 0.1mg/m3 L • Minimum detection limit of 0.05 mg/m3 and certification range of 0-15 mg/m3 and measurement range 0-200 mg/m3 • Laboratories and Research Centres • nspection frequency: 6 months I • Process Control • o velocity restrictions in processes N between 8m/s-20m/s Data Acquisition Software In conjunction with the SMS a1-cbiss are able to offer market leading MCERTS accredited data acquisition and reporting software complete with live CV calculation. • Combustion Monitoring MCERTS Certification Range: TPM: 0-15mg/m3 • onstant velocity required outside C this range • or stack diameters: 500mm to 3m F (multi-sensor configuration required for stack 3m) • nclosure temperature rating -25°C to E +55°C 7 Tel: 0151 666 8300 www.a1-cbiss.com • Long term zero drift: 0.1mg/m3 Specifications: • Power supply: 110v or 230v • Inspection frequency: 3 months • Air purge requirements: 30 to 40 litres/ minute unaffected by changes in velocity How Does the System Work? The sample intake is provided through a heated sample probe with large surface filtration. The sample conditioning system includes a high performance cooler. The heat exchanger is constructed in a way to minimise the loss of water soluble compounds. The sample gas is appropriately filtered in order to remove solid particulates and any acid aerosols. The sample conditioning equipment in total consists of a condensate detector, condensate pump and sample pump. • Enclosure temperature rating -25°C to +55°C Applications: • asification G • Anaerobic Digestion • iogas B • Probe length 700mm or 1400mm • Operating temperature: +5°C to +40°C What Does the System Measure? • O • H2 • CO2 • O2 • CH4 C • ption to add additional parameters to meet gasification O process Model Gas Accuarcy Stability Gascard NG CO +/- 2% of range 2% of range over 12 mths CH4 CO2 K1550 H2 +/- 2% FSD 1% FSD per month 8
  • 6. AMESA Bacharach Dioxins Furans Emissions Sampler Combustion Analysers Datasheet ECA 450 The AMESA is fast becoming the system of choice for new build energy from waste plants for the continuous sampling of dioxins and furans as standard. The ECA 450 from Bacharach is ideal for professionals to conduct accurate combustion and emissions tests whilst improving overall combustion efficiency, reducing fuel costs, and determining emissions compliance. The ECA 450 takes continuous samplings of furnaces, boilers and other industrial combustion equipment for up to 8 hours and generates precise, reliable combustion and environmental measurements and calculations. It generates this complex data easily — even at selected intervals - enabling plants to make more accurate equipment adjustments and better assess pollution levels. The continuous dioxin and furan sampling system makes it possible to sample trace pollutants such as dioxins and furans. The AMESA® is MCERTS accredited and complies with EN1948. Fully supported by AMLEIT monitoring software and MCERTS Certified CDAS Elite Data Aquisition Software. Specification Applications: Features Benefits: MCERTS Certification Ranges: • Municipal, Hazardous Hospital Waste Incineration • ontinuous automatic sampling C giving a more accurate representation of the sample Measures: • xygen (O2), Carbon Monoxide (CO), Nitric Oxide (NO), O Nitrogen Dioxide (NO2), Sulphur Dioxide (SO2) • ombustibles, Temperature Draft. It also calculates C combustion efficiency, excess air, carbon dioxide, NOx (Nitrogen Oxides) and pollution units Features and Benefits: • arge, easy-to-read fluorescent display that is visible from L wide angles • odular design lets you add sensors as your needs M change • uilt-in printer and complete data downloading to a PC B capability • tores over 1000 individual combustion and/or pressure S test records, which can later be recalled for viewing or printing Isokinetic Sampling Velocity: • Energy From Waste (EFW) • Production Plants • Recycling Plants • Cement Kilns • Metallurgic Plants • Pulp and Paper • utomated datalogging recording A over a period of 6 hours up to 30 days • atalogging including: flue gas D velocity, sample gas flow volume, flue gas temperature and cartridge temperature as half-hourly average • imultaneous monitoring of up to S 4 sample streams with 1 AMESA system • emote control functionality available R • educed costs due to optimisation of R the built-in dioxin reduction stages PCA 3 • -20m/s 2 a1-cbiss are pleased to announce the launch of the new Bacharach PCA®3, the industry’s first advanced portable combustion analyser with a full colour graphic display for superior visibility and user-friendly interface and the most sensor configuration flexibility in its class. Features and Benefits: • Sensors can easily be added or removed in the field without down time, using the B-Smart® pre-calibrated sensor options. Measures: • n addition to the included Oxygen I (O2) and Carbon Monoxide (CO) The PCA®3 is the definitive combustion sensors, the PCA®3 can be ordered and emissions analyser that enables with CO (high), Nitric Oxide (NO), fast and accurate measurement Nitrogen Dioxide (NO2) and Sulphur for on-demand or semi-continuous Dioxide (SO2) sensors. sampling of light industrial, institutional, commercial and residential furnaces, boilers and appliances. • lue transparency F 9 Tel: 0151 666 8300 www.a1-cbiss.com 10
  • 7. CDAS Report C D A S CDAS Report is an offline package that allows reports and graphs to be generated. CDAS Report offers the flexibility to configure reports to meet the requirements of the site permit and the EA. Sira MC090153/00 Environmental CDAS Data Acquisition Reporting and Network Packages Each report can be generated at any time without interrupting the data collection process. Reports are simple to generate using the report wizard. What is CDAS? EN14181 CDAS is the market leading MCERTS accredited (parts A, B, C1 C2) Data Acquisition package that retrieves data from a range of instruments for CEMS, Gas Detection and Sampling applications. The CDAS software meets the stringent demands of WID, LCPD, EN14181, IPPC and customer specific requirements. From data logging to data processing, trending and reporting, the CDAS software suite provides the flexibility to supply a complete solution for your site. Standard CDAS Features: Typical communications protocols include serial, Ethernet, analogue and digital I/O. Other protocols are supported such as Modbus, OPC and PROFIBUS, for easy interfacing to a PLC. CDAS eases the burden of EN14181 compliance as it allows application of QAL2 calibration functions and performs automatic QAL3 Testing • Dual Redundant Data Collection • Automatic Period Reports • Communicates via Remote Analogue I/O • Correction to Standard Reference Conditions • llows application of EN14181 Calibration A Functions C D A S • Performs Automatic EN14181 QAL3 Testing • Graphing Options • Configurable Alarms • Searchable Alarm History Screen Based on market feedback and regular communications with existing customers, a1-cbiss are launching the new CDAS platform with improved features to support evolving requirements NEW CDAS Features in 2011: • Windows 7 Compatability • Specific Gas Bottles Associated to QAL3 Test Data Collection, Processing Visualisation CDAS acquires data in real time. Real time data then converted to: • Raw Data (Instrument Value) CDAS allows the data to be viewed in a fully configurable screen layout to support individual preferences via preset and customisable data channels. Dual Redundancy To maximise data capture, two copies of CDAS can be set up in a duty/standby dual redundant arrangement. The standby machine connects to the duty machine and is supplied with live data. If the standby machine detects that the live data supply is interrupted then it will attempt to collect data from the instruments itself. • Simultaneously Performs Multiple QAL3 Tests from a Mixed Gas Bottle • Multi Language Support • Calibrated Data (EN14181 QAL2 Calibration Function) • Corrected Data (Reference Conditions) • Adjusted Data (Reportable Values) A data file for each of the conditions above is written to the hard disk. CDAS does not delete any data that it has recorded. 11 Tel: 0151 666 8300 www.a1-cbiss.com 12
  • 8. Service Support Service Contract Benefits The a1-cbiss philosophy differs from our competitors in that we firmly believe quality should continue far beyond supply. All systems are supported by our dedicated service department to provide repair, calibration, preventative maintenance, software support and remote diagnostics - 24 hour / 7 days per week to our customers Our wealth of knowledge and experience ensures you meet legislative requirements with no downtime, therefore maximising your investment. Additional benefits include: With the largest dedicated CEMS service support network in the industry, a1-cbiss have fully factory trained industry specialists on hand to provide full customer service and support • OMA - Pre audit check and OMA audit attendance Ongoing service support is integral to the a1-cbiss offering. With a comprehensive service support package that is fully flexible to meet customer specific, legislative or budgetary requirements, offering peace of mind that equipment is covered for all eventualities • Flexibility to suit your requirements • EN14181 consultancy and compliance support • Full operator system training • Reduced downtime to improve plant efficiency Typical Service Contract Comprises: • 4 scheduled service and calibration visits per year • All parts, labour and travel inclusive • Guaranteed response time from 6 hours • Site allocated service engineer • Fully inclusive of warranty and breakdown cover • 24/7 regional service support • Remote diagnostics support • Unrivalled industry experience • Legislation compliant service documentation • Regional on-call service engineer 24/7 • EN14181 compliant functional checks • Comprehensive stockists of critical spare parts and consumables • egional service structure R • edicated engineers allocated to your site D to improve customer relations and quality of service • ost experienced CEMS service team in the M UK with combined industry experience of over 150 years Paul Morgan Southern Area Sales Service Manager Training: a1-cbiss can provide a comprehensive training package to meet all of your site requirements. Our service department can also provide full system training for your staff, advice and support for OMA surveys and advice and guidance on all relevant legislation. We offer structured training programs for all of our CEMS equipment, which would comprise of the following topics: • Advanced system technical training • Advanced system CDAS training • bjective CEMS specification consultancy to meet O permit requirements • Legislation specific • EN14181 - QAL3 13 Tel: 0151 666 8300 www.a1-cbiss.com 14
  • 9. Client Reference Lists Client Testimonials Veolia, Ellesmere Port Peake GB Ltd, Cornwall Dalkia, Chilton MES, Wolverhampton “ W e became aware of a1-cbiss and their emissions monitoring systems through our operational involvement on one of our Contract Energy Management contracts in the NorthEast of England. were in the design phase of a new wood chip burning Power Station and, as relative We newcomers to this field, we received a great deal of technical guidance from a1-cbiss regarding WID compliance. London Waste, Edmonton MES, Dudley, CNIM, States of Jersey MES, Stoke Inco Europe, London Veolia SELCHP Deptford , We look forward to working with them during the commissioning phase of the station. Voelia, Tyseley Metso, Markinch Scotland Peter Cleary Senior Project Engineer Dalkia Energy Hampshire Waste, Chineham Slough Heat Power Ltd Hampshire Waste, Marchwood EON UK Ltd, Ironbridge Hampshire Waste, Portsmouth EON UK Ltd, Kingsnorth Qinetiq Ltd, Essex EON UK Ltd, Castleford Coventry Solihull EON UK Ltd, Killingholme were particularly impressed by the fact that the CEMS is 100% engineered by a1-cbiss We including the CDAS software and also received a very competitive tender return compared to their rivals in this field. “ “ ” ” EON UK Ltd, Sandbach Whiterose Environmental Ltd, Kent Coryton Power, Stanford-le-hope DSTL, Wiltshire EON UK Ltd, Stoke on Trent Lakeside EFW, Colnbrook EON UK Ltd, Ratcliffe Grundon Waste Management Ltd, Berkshire 15 Tel: 0151 666 8300 www.a1-cbiss.com W SP regularly partner with a1-cbiss to ensure our permitting clients get the best technical advice and response to their CEMS needs. Neal Barker Technical Director WSP Environment and Energy Borders General Hospital, Melrose W e have been using a1-cbiss since the plant was built for their expertise, technical guidance and market leading equipment. The equipment we have onsite is the MIR-FT system combined with a GR52M FID and the a1-cbiss data acquisition software CDAS Elite. The complete CEM system has proven to be very reliable and dependable over the years. One of the key benefits to us is the CDAS elite software package which is easy to use and extremely flexible meeting all our site requirements. The a1-cbiss engineers offer exceptional support, as well as being professional and knowledgeable. The a1-cbiss legislative consultancy approach has been invaluable and helped contribute to us achieving one of the highest OMA scores in the industry. Andy McQueen EFW Facility Plant Manager Veolia Chineham ” 16
  • 10. Case Study Power Industry the Result a1-cbiss manage all aspects of the project from design build, installation and commissioning, through to on-going service and support. the Background Because of ageing equipment and increasing issues surrounding reliability, one of Europe’s leading power suppliers decided to roll out a series of site upgrades to replace their continuous emission monitoring systems (CEMS) at a coal fired power station and two gas turbine sites across the UK. The coal fired power station saw the installation of nine MIR9000 multi-gas MCERTS accredited analysers comprising of four duty MIR9000 systems and 1 standby MIR9000 with a changeover system for redundancy. The analysers are integrated into a purpose built enclosure, all communicating via the MCERTS certified CBISS Elite Data Acquisition Reporting software (CDAS) which also incorporates the IVIS hardware panel allowing for QAL 3 functionality. The gas turbine site saw the installation of seven MIR9000 CLD multi-gas analysers. Again the analysers are integrated into a purpose built enclosure, all communicating via the MCERTS certified CBISS Elite Data Acquisition Reporting software (CDAS) which also incorporates the IVIS hardware panel allowing for QAL 3 functionality. the Challenge 1. o supply CEMS that complies with the requirements of MCERTS, the large combustion plant directive (LCPD) and the T industrial emissions directive (IED), which is due to be enforced in 2016 2. To include a system redundancy option at the coal fired power station to prevent any downtime Design and Build 3. o monitor temperature, pressure and flow measurement directly from the flue and establish communications between T the analysers and Data Acquisition Reporting Software 4. he coal fired power station required the systems to be installed in the main exit flues (within one concrete windshield), T at a height of 75 meters above ground level 5. he incumbent systems were not provided by a1-cbiss, therefore a1-cbiss would have to prove that their solution, T service and support is superior to the incumbent supplier Purpose Built Enclosure the Solution At the coal fired power station, a1-cbiss proposed an MCERTS accredited MIR9000 infrared multi-gas analyser that monitors extracted samples on a dry basis, using a SEC sample conditioning system. The SEC sample conditioning system comprised of an in-situ probe, a permeation dryer unit and a temperature, pressure and flow module integrated into the same probe. A permeation dryer eradicates the requirement for long lengths of heated line. The MIR9000 system MCERTS accreditation is based on the Emission Limit Values (ELV) of the waste incineration directive, and subsequently future proofs the site for the ELV change when the IED comes into force in 2016. Using a single probe for measuring all of the required parameters reduced the number of penetrations in the flues and consequently lowered the cost of installation. The option for system redundancy was addressed by proposing a fully automated change-over system with an additional MIR9000 analyser. The system would be fully controlled by the CDAS software, therefore requiring minimal user intervention and eliminating any risk of downtime. For the gas turbine site, a1-cbiss proposed MIR9000 CLD chemiluminescence and infrared multi-gas analysers that monitor extracted samples on a dry basis, using a SEC sample conditioning system. The SEC sample conditioning system comprised of the same elements as used in the MIR9000 system. The CLD system fully complies with the standard reference method (SRM) EN 14792 for the measurement of NOx. The CLD also has MCERTS certification that complies with the new limits in the IED. Installation Commissioning Service support is integral to the a1-cbiss offering. With the largest service network in the industry and nationwide coverage, the dedicated team of service engineers provide service, repair maintenance on all equipment supplied. 17 Tel: 0151 666 8300 www.a1-cbiss.com 18