SlideShare une entreprise Scribd logo
1  sur  147
Brecknell
1000 Armstrong Drive
Fairmont, Minnesota 56031
Toll Free: 800-637-0529
Telephone: 507-238-8702
Fax: 507-238-8271
Email: sales@brecknellscales.com
Brecknell
Foundry Lane
Smethwick, West Midlands England B66 2LP
Telephone: +44 (0) 845 246 6717
Fax: +44 (0) 845 246 6718
Email: sales@brecknellscales.co.uk
Www.brecknellscales.co.uk
Brecknell
217 Brunsweick Boulevard
Pointe-claire, Quebec Canada H9R 4R7
Toll Free: 800-268-1662
Telephone: 416-213-9900
Fax: 416-213-9960
Email: sales@brecknellscales.ca
Salter India Limited
Plot #53, Sector 25, (Avery India Compound)
Ballabgarh 121 004, Faridabad,
Harvana (India)
Telephone: 91-129-4094400
Fax: 91-129-4094591, 2234091
Email: Sales@averyindia.net
Www.salterindia.com
Manufacturer Models Excitation + Excitation - Signal + Signal - Shield Sense + Sense -
A&D Engineering RED WHITE GREEN BLUE YELLOW
Allegany Technology GREEN BLACK RED WHITE BARE
Advance Transducers RED BLACK GREEN WHITE BARE
Allegany GREEN BLACK WHITE RED BARE
Alphartron RED BLACK GREEN WHITE BARE
Anyload RED BLACK GREEN WHITE BARE
108LSMT GREEN BLACK RED WHITE BARE BLUE BROWN
Artech RED BLACK GREEN WHITE BARE
Avery Weigh-Tronix GREEN BLACK WHITE RED WHITE/ORANGE
Beowulf GREEN BLACK WHITE RED BARE
BLH GREEN BLACK WHITE RED YELLOW
Cas RED BLACK GREEN WHITE BARE BLUE BROWN
Celtron RED BLACK GREEN WHITE BARE
Cardinal GREEN BLACK WHITE RED BARE
CNCell RED BLACK GREEN WHITE BARE
Coti GREEN BLACK WHITE RED BARE
Digi RED WHITE GREEN YELLOW GRAY
Dillon CANISTER TENSION RED BLACK GREEN WHITE ORANGE
COMPRESSION RED BLACK WHITE GREEN ORANGE
Z-CELL RED BLACK WHITE GREEN ORANGE
Electroscale RED BLACK GREEN WHITE BARE
Epelsa RED BLACK GREEN WHITE BARE VIOLET GRAY
Evergreen GREEN BLACK WHITE RED BARE
Flintec PC1,PC2,PC6,RC1,SB4,SB5,SB6,SB14,SLB,UB1,UB6,SB10, PCB,BK2 GREEN BLACK WHITE RED YELLOW
Force Measurement RED BLACK GREEN WHITE BARE
General Sensor RED BLACK GREEN WHITE BARE
Genisco RED BLACK GREEN WHITE BARE
GSE RED BLACK WHITE GREEN BARE
HBM SBF,SB3,USBU1T,Z6, H35 GREEN BLACK WHITE RED YELLOW
BLC,BLF,JRT,PWS,RSC GREEN BLACK WHITE RED YELLOW
PLC,B35, SBE RED BLACK GREEN WHITE YELLOW
BBS GREEN BLACK WHITE RED BARE
SP4, SP10,PW15,PWS,PWSM GREEN BLACK WHITE RED YELLOW ORANGE BLUE
PW12,PW16,C16,PW15AH BLUE BLACK WHITE RED YELLOW GREEN GRAY
Interface SSM,1200,3200 RED BLACK GREEN WHITE BARE
Kubota RED WHITE GREEN BLUE YELLOW
LeBow RED BLACK GREEN WHITE BARE
Mettler Toledo WHITE BLUE GREEN BLACK ORANGE YELLOW RED
National Scale GREEN BLACK WHITE RED YELLOW
Nikkei RED BLACK GREEN WHITE BARE
NCI RED BLACK WHITE GREEN BARE YELLOW BLUE
NMB RED WHITE GREEN BLUE BARE
Ormond RED BLACK GREEN WHITE BARE
Pennsylvania ORANGE BLUE GREEN WHITE BARE
Pesage Promotion BLUE WHITE RED BLACK YELLOW
Philips RED BLUE GREEN GRAY BARE
Revere Transducers 62HU,63HU,363,953,9523 RED BLACK GREEN WHITE BARE
92CC,93CC,24U,43U,263D,462,6762, 9102, 9103, 9123,9363,5102,5103, 5123, 5223,
5723, 9363
RED BLACK GREEN WHITE ORANGE
392B,642,652,692B2,BSP,HPS, USP1 GREEN BLACK WHITE RED BARE
792, 933, SHB, SSB GREEN BLACK WHITE RED CLEAR
CP1,CSP1 GREEN BLACK WHITE RED ORANGE
RLC PINK GRAY BROWN WHITE BARE
Rice Lake Weighing RL20000,RL20000SS,RL20001HE,RL30000,RL75061,RL50500,
RL70000SS,RL71000HE,RL75016HE
RED BLACK GREEN WHITE BARE
RL35023,RL35023S,RL35082,RL35083,RL39123,RL75223,RL90000,RLETB,
RLETS,RLHSS,RLMK4
RED BLACK GREEN WHITE BARE
RL39523,RL50210,RL56044,RL70000,RL75016,RL75016SS,RL75040A,
RL75058,RL75060
RED BLACK GREEN WHITE BARE
RLMK1 RED BLACK WHITE GREEN ORANGE YELLOW BLUE
RLMK15,RLMK21 RED BLACK GREEN WHITE ORANGE
RL1521A GREEN BLACK RED WHITE BARE
RL40BBS,RLBLC,RLSB2,RLSB2L,RLSB2M,RLSB250,RLSSB,RLKIS,
RL9000TWM,RL75114,RLSCA,RLBLP,RLSB2MLW
GREEN BLACK WHITE RED BARE
RL8C2P1SS,RLCSP1,RL75000SS,RL30745 GREEN BLACK WHITE RED ORANGE
RL1380,RL1385,RLH35,RL30745,RLPC6 GREEN BLACK WHITE RED YELLOW
RLPCB-60 GREEN BLACK WHITE RED YELLOW BLUE BROWN
RL1010,RL1040,RL1140,RL1250,RL1260 GREEN BLACK RED WHITE BARE BLUE BROWN
RLHBB,RLHTO BLUE BLACK WHITE RED BARE GREEN GRAY
RL32155 WHITE BLUE GREEN BLACK ORANGE YELLOW RED
Scaime BROWN GREEN YELLOW BLACK WHITE GRAY PINK
Sensortronics RED BLACK GREEN WHITE BARE
Sensotec RED BLACK WHITE GREEN BARE
Strainsert RED BLACK GREEN WHITE BARE
T-Hydronics RED BLACK GREEN WHITE BARE
Tedea Huntleigh GREEN BLACK RED WHITE BARE BLUE BROWN
Thames Side RED BLUE GREEN YELLOW BARE
Toledo GREEN BLACK WHITE RED YELLOW
Totalcomp RED BLACK GREEN WHITE BARE
Transducers Inc. RED BLACK GREEN WHITE ORANGE
Transcell RED BLACK GREEN WHITE
Vishay BLH C2P1,C3P1,T2P1,T3P1 GREEN BLACK WHITE RED YELLOW
Vishay Celtron PSD,SEB,LCD,CSB,DSR,LOC,SQB,STC,STCSS,DSR,CLB,HED,DLB,SQB,HSS RED BLACK GREEN WHITE BARE
LPS RED BLUE GREEN WHITE BARE
HOC,MOC GREEN BLACK RED WHITE BARE BLUE BROWN
Vishay Sensortronics 60001,60008,60018,60030,60036,60040,60048,60048SS,60050,60051,60060,
60060-101,60063,65007,65016,65016SS
RED BLACK GREEN WHITE BARE
65016W,65023,65023S,65023SS,65024,65040A,65040S,
65058S,65061A,65083,65083S,65114
RED BLACK GREEN WHITE BARE
6007, 60064 GREEN BLACK WHITE RED BARE
65088-1000,65088-1114 GREEN BLACK WHITE RED ORANGE
Vishay Tedea-huntleigh 4157, 4158 RED BLACK GREEN WHITE BARE
3411, 3421 RED BLACK GREEN WHITE BARE BLUE BROWN
240, 1010, 1022, 1040, 1140, 1250, 1260, 1320,9010, 605, 1030, 1240, 1241, 1030,9010,
1030,1320,1510
GREEN BLACK RED WHITE BARE BLUE BROWN
355, 620, 3510 BLUE BLACK WHITE RED BARE GREEN GRAY
Wiring Guide
Central Carolina Scale, Inc
5393 Farrell Road
Sanford NC 27330
PH: 919-776-7737
www.CentralCarolinaScale.com
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
CANADA
TEL: 416-213-9900
WWW.BRECKNELLSCALES.CA
INDIA
TEL: +91 129 4159774/75/76
WWW.SALTERINDIA.COM
Additional 20% off list price
on orders over 1,000 NET
Use Promo Code SBWP250 to receive discount
st
Valid through March 31 , 2013
Free freight
on orders over 1,000 NET
(not to be used with any other discounts/specials)
Use Promo Code SBWP254 to receive discount
st th
Valid May 1 - 29 , 2013
Receive 10% off list price on any
Brecknell Indicator order over 1,000 NET
(to view indicators visit
or your Brecknell Global Catalog)
Use Promo Code SBWP255 to receive discount
st st
Valid July 1 - 31 , 2013
www.brecknellscales.com, www.brecknellscales.co.uk
Brecknell Revere HBM Tedea Celtron Sensortronics Coti Artech Rice Lake Totalcomp BLH Fairbanks NMB Thurman Transcell Flintec Vishay
BCL 1004
L6B 1004
L6C
H2A
H2D
H2F
H2J1
L3H
H3 STC 60001-0221 COMPACT CISB
H3C
H3E
H3F STC 60001,60036,RTI363 CISB
H3G M363 STC 60001 20210 RL20000 / 20001 BSA / BSS STC
H3G-Y 363 STR 60001
H3Y
L3H 6362
L6D 640 PW6-2 1022 LPS 600g ~ 35kg CI-22 61022 RL1521 C2G1 4900 C2C1 C2G1 / LPS
L6D4 PW6K 1022 LPS
L6D5
L6E LPS
L6E3 1263
L6F 1320 HOC
L6G 672 LOC FAV
L6H
L6Q 650 1241 LPS 60kg ~ 200kg
L6J
L6J1 1006
L6J5
L6L
L6N 642 SP4 1042 MT1041 RL1042
L6S 1030
L6T 652 1252
L6X
L6Y
H6G5
H6B
H8 SB3
H8A
H8B Z7
H8C 5123 3411 SQB 65023 CI-23 30310 RL35023 TSB SBS SQB
H8K 5723
H9A
H9B MDB
H9C 5103
H9D 5203 DSR 65016 CI-16 70510 RL75016 DSR
H9G
H9G1
H9C-Y 5103 CSB 60058 CI-5103 70210 RL70000
H9D-Y 5203
H9H DLB 65040A BE40 80310 RL75040 TDE40 TSC840 DLB
H9N 5303 4158 CLB 65058 CI-58 RL75058 CLB
H10
H10A
B3G M9363 STC 60050
B3G-Y 9363 STR 60050
B8D M9123 3410 SQB 65023
B8D-Y 9123 3421 SQB 65023
B8H ALC HVC 65083S
BM6A 60064
B8K 9723
BM8D H35
BM8L 9113
BM8F 9523
BM8H ACB HLC HVC 65084
BM8G SSB SB3 CI-SB3 SS30610 RLSSB
HM8
B9C-Y 9103 CI-5103-SSW RL7100HE
B9D-Y 9203 DSR-HSS 65016W CI-16-SSW RL75016SS DSR-HSS
B9E-Y 9223
B9F-Y 9323 DLB SS 65040S BE40-SSW RL75040A TSC840
B9N 9303 65058SS
B9H-Y 9903 DLB SS 65040S BE40-SSW RL75040A
B9J 9803
B9K 9423
HM9B
HM9E-Y 5223 HED 65040-1127W CI-5223 80210 RL75223 TSC800
BM11 SHB Z6 355 HBB RLHBB HBB
BM14A CSP 65088-1000 CP26S5 90310 RLCSP1 TCSP1
BM14C
BM14G ASC
BM14K C16 CP26S4
HM14C
B14H CCC
B14D
H24L
HM24M
BM24R RLC
PW12 1250 RL1250 PCB LOC
B6Q 1241 S.S.
Cross Reference Guide
*Standard ground freight only *Valid for orders from inter-country stocking locations
Brecknell
1000 Armstrong Drive
Fairmont, Minnesota 56031
Toll Free: 800-637-0529
Telephone: 507-238-8702
Fax: 507-238-8271
Email: sales@brecknellscales.com
www.brecknellscales.com
Brecknell
Foundry Lane
Smethwick, West Midlands England B66 2LP
Telephone: +44 (0) 845 246 6717
Fax: +44 (0) 845 246 6718
Email: sales@brecknellscales.co.uk
www.brecknellscales.co.uk
Brecknell
217 Brunswick Boulevard
Pointe-Claire, Quebec Canada H9R 4R7
Toll Free: 800-268-1662
Telephone: 416-213-9900
Fax: 416-213-9960
Email: sales@brecknellscales.ca
www.brecknellscales.ca
Salter India Ltd.
Plot #53, Sector 25, (Avery India Compound)
Ballabgarh 121 004, Faridbad,
Harvana (India)
Telephone: 91-129-4094400
Fax: 91-129-4094591, 2234091
Email: sales@averyindia.net
Www.averyindia.co.in
CONTACT INFORMATION
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
CANADA
TEL: 416-213-9900
WWW.BRECKNELLSCALES.CA
INDIA
TEL: +91 129 4159774/75/76
WWW.SALTERINDIA.COM
COMPANY HISTORY
Brecknell, part of Avery Weigh-Tronix, a proud
member of the Illinois Tool Works (ITW)
company, celebrated 250 years of customer
commitment and history in 2011. Founded in
1761, under Salter Brecknell, Brecknell has
grown to become a global leader in weighing
solutions. Brecknell products are designed and
constructed with focus on high-value solutions
and accuracy for easy operation for all your
weighing applications.
Today, Brecknell products can be found for most
weighing applications. The Brecknell global
footprint and reach allows Brecknell to offer the
highest quality of service an support to our
customers.
Fairmont, Minnesota
Birmingham, England
Montreal, Canada
India
Naming System of Load Cell / Force Transducers
2
1kg/cm
3m
Naming System of Weighing Assembly
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
Material:
H: Alloy Steel
B: Stainless Steel
L: Aluminum
Accuracy:
N3: NTEP 3000 Division
N5:
N10:
G1: 0.1% Accuracy
G2: 0.2% Accuracy
G3: 0.3% Accuracy
NTEP 5000 Division
NTEP 10,000 Division
C1: OIML Certified 1000 Division
C2: OIML Certified 2000 Division
C3: OIML Certified 3000 Division
C3D: OIML Certified 2500 Division
C3G: OIML Certified 4000 Division
Sealing:
No mark: Adhesive potted
M: Hermetic welded
XXXXX XX X XXXXX
d: Digital load cell
t: High temperature
working
Different Series of
Appearance:
A, B, C, D, E, E3, F, G,
G5, H,H5, J, L, N, Q,
OC3, W
Thread:
No mark: Metric
Y: Imperial
Type & Structure:
2: Spoke Type
3: S-Beam
6: Single Point
8: Single Shear Beam
9: Dual Shear Beam
11: Single Point with Bellow
14: Column type
16: Dual Parallel Beam
Capacity:
lb: Pounds (lb)
K: Klb
Kg: Kilograms
t: Metric tons
N: Newtons
KN: Kilo Newtons
MN: Million Newtons
SE: Small Envelope
LE: Large Envelope
Material:
H: Alloy Steel
B: Stainless steel
L: Aluminum
Assembled Load Cell Type:
2: Spoke Type
3: S-Beam
6: Single Point
8: Single Shear Beam
9: Dual Shear Beam
11: Single Point with Bellow
14: Column type
16: Dual Parallel Beam
Structure:
J: Foot
Y: Load button
D: Plate
L: Ring
M: Mounting
XX XX XXX XX / XX
Series Number:
Defined by number or letter Capacity Range
Load Cell Protection Class
Reference to National Standard of the Cover Protection Class System (P.R.C.)
Equal to IEC529 Standard (International Electrotechnical Commission
IP-6-
Protection Level
Class
Description Meanings
Experimental Method
Achieved
Protection Class
5
6
7
8
Adhesive sealed common load
cell could achieve
Cover sealed inner adhesive
protected load cells could
achieve
Cover (or bellow) welded, inner
adhesive protected load cells
could achieve. Besides of oil-proof,
water proof, it also can proof the
common corrosive gas and medium
Special required load cells
could be customized
Water-
sprinkle
proof
Not be affected by the
water-sprinkle from
any direction in a
short time
Not be affected by the
strong water-spray
from any direction
in a short time
Not be affected by the
inundating into
water in a stated pressure
and time
Can dived into
water for a long time
Water-
sprayed
protection
Soggy
Proof
Diving
Proof
Decided individually
Inundate into 1 meter
deep water for 30 minutes
Continually spray water from any
direction more than 15 minutes
Continually spray water from any
direction more than 15 minutes
Can dived into
water for a long time
Dust-pro (dust could not be introduced to the inner part.)
SoggyProtectionClass
2
1kg/cm
1m
1m
International Protection
Naming System of Load Cell / Force Transducers
2
1kg/cm
3m
Naming System of Weighing Assembly
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
Material:
H: Alloy Steel
B: Stainless Steel
L: Aluminum
Accuracy:
N3: NTEP 3000 Division
N5:
N10:
G1: 0.1% Accuracy
G2: 0.2% Accuracy
G3: 0.3% Accuracy
NTEP 5000 Division
NTEP 10,000 Division
C1: OIML Certified 1000 Division
C2: OIML Certified 2000 Division
C3: OIML Certified 3000 Division
C3D: OIML Certified 2500 Division
C3G: OIML Certified 4000 Division
Sealing:
No mark: Adhesive potted
M: Hermetic welded
XXXXX XX X XXXXX
d: Digital load cell
t: High temperature
working
Different Series of
Appearance:
A, B, C, D, E, E3, F, G,
G5, H,H5, J, L, N, Q,
OC3, W
Thread:
No mark: Metric
Y: Imperial
Type & Structure:
2: Spoke Type
3: S-Beam
6: Single Point
8: Single Shear Beam
9: Dual Shear Beam
11: Single Point with Bellow
14: Column type
16: Dual Parallel Beam
Capacity:
lb: Pounds (lb)
K: Klb
Kg: Kilograms
t: Metric tons
N: Newtons
KN: Kilo Newtons
MN: Million Newtons
SE: Small Envelope
LE: Large Envelope
Material:
H: Alloy Steel
B: Stainless steel
L: Aluminum
Assembled Load Cell Type:
2: Spoke Type
3: S-Beam
6: Single Point
8: Single Shear Beam
9: Dual Shear Beam
11: Single Point with Bellow
14: Column type
16: Dual Parallel Beam
Structure:
J: Foot
Y: Load button
D: Plate
L: Ring
M: Mounting
XX XX XXX XX / XX
Series Number:
Defined by number or letter Capacity Range
Load Cell Protection Class
Reference to National Standard of the Cover Protection Class System (P.R.C.)
Equal to IEC529 Standard (International Electrotechnical Commission
IP-6-
Protection Level
Class
Description Meanings
Experimental Method
Achieved
Protection Class
5
6
7
8
Adhesive sealed common load
cell could achieve
Cover sealed inner adhesive
protected load cells could
achieve
Cover (or bellow) welded, inner
adhesive protected load cells
could achieve. Besides of oil-proof,
water proof, it also can proof the
common corrosive gas and medium
Special required load cells
could be customized
Water-
sprinkle
proof
Not be affected by the
water-sprinkle from
any direction in a
short time
Not be affected by the
strong water-spray
from any direction
in a short time
Not be affected by the
inundating into
water in a stated pressure
and time
Can dived into
water for a long time
Water-
sprayed
protection
Soggy
Proof
Diving
Proof
Decided individually
Inundate into 1 meter
deep water for 30 minutes
Continually spray water from any
direction more than 15 minutes
Continually spray water from any
direction more than 15 minutes
Can dived into
water for a long time
Dust-pro (dust could not be introduced to the inner part.)
SoggyProtectionClass
2
1kg/cm
1m
1m
International Protection
Table of Contents - Numeric
H2F
H3
H3F
B3G
H3G
BM3
L3V
L6B
L6C
L6D
L6D21
L6E
B6E
H6E
L6E3
B6E3
L6F
B6F
H6F
L6G
B6G
H6G
H6G5
L6H5
L6J
L6J1
L6L
L6N
B6N
L6Q
B6Q
L6T
L6W
38
39
40
BM6A
BM6E
BM6G
41
42
43
HM8
H8C
HM8C
44
45
46
B8D
BM8D
H8H
47
48
49
50
51
BM8H
H8Q
B8Q
B9B1
HM9B
52
55
56
53
54
57
58
59
60
61
62
63
65
64
66
67
68
69
70
71
72
B9C
H9C
HM9C
B9D
H9D
B9E
HM9E
B9F
B9H
H9H
B9N
H9N
BM11
HM11
BM14A
BM14C
HM14C
BM14D
BM14G
HM14H
BM14K
Accessories
97
97
98
98
99
100
100
101
101
102
102
HL-3-001
HL-3-002
HL-3-003
HL-3-004
HL-3-005
HJ-8-201
BJ-8-202
HJ-8-203
BJ-8-205
BJ-8-206
BJ-8-207
103HJ-8-213
103
104
104
105
105
106
BJ-8-215
HJ-8-216
HJ-8-217
HJ-8-218
BJ-8-219
BJ-8-220
106
107
107
HD-8-301
HY-8-101
HY-8-102
108BY-8-104
108BY-8-106
111
112
HY-14-104
BY-14-105
110
111
BY-14-102
BY-14-103
Junction box
133
134
135
136
137
JB01
JB02
JB05A
JB06
JB07
Transmitter
138
139
140
FD-3
FD-4
FD-5
5BM24R
Miniature Sensors
73
74
75
76
78
79
80
81
82
1A
1B
IF6-S
1HM
1R1-K
1V3-350
1X1
1Z
2A
83
84
85
2C1
2F
004-G
86
87
88
CF-1
Q45X10
Q45X6
89
90
91
Q70X5
Q84X5
S6400
92DB-1
771P Series
93DB-2 93DB-2
94FAB
95YA-6
96YA-7
109BY-14-101
H2F
H3
H3F
B3G
H3G
BM3
L3V
L6B
L6C
L6D
L6D21
L6E
B6E
H6E
L6E3
B6E3
L6F
B6F
H6F
L6G
B6G
H6G
H6G5
L6H5
L6J
L6J1
L6L
L6N
B6N
L6Q
B6Q
L6T
L6W
38
39
40
BM6A
BM6E
BM6G
41
42
43
HM8
H8C
HM8C
44
45
46
B8D
BM8D
H8H
47
48
49
50
51
BM8H
H8Q
B8Q
B9B1
HM9B
52
55
56
53
54
57
58
59
60
61
62
63
65
64
66
67
68
69
70
71
72
B9C
H9C
HM9C
B9D
H9D
B9E
HM9E
B9F
B9H
H9H
B9N
H9N
BM11
HM11
BM14A
BM14C
HM14C
BM14D
BM14G
HM14H
BM14K
Accessories
97
97
98
98
99
100
100
101
101
102
102
HL-3-001
HL-3-002
HL-3-003
HL-3-004
HL-3-005
HJ-8-201
BJ-8-202
HJ-8-203
BJ-8-205
BJ-8-206
BJ-8-207
103HJ-8-213
103
104
104
105
105
106
BJ-8-215
HJ-8-216
HJ-8-217
HJ-8-218
BJ-8-219
BJ-8-220
106
107
107
HD-8-301
HY-8-101
HY-8-102
108BY-8-104
108BY-8-106
111
112
HY-14-104
BY-14-105
110
111
BY-14-102
BY-14-103
Junction box
133
134
135
136
137
JB01
JB02
JB05A
JB06
JB07
Transmitter
138
139
140
FD-3
FD-4
FD-5
5BM24R
Miniature Sensors
73
74
75
76
78
79
80
81
82
1A
1B
IF6-S
1HM
1R1-K
1V3-350
1X1
1Z
2A
83
84
85
2C1
2F
004-G 86
87
88
CF-1
Q45X10
Q45X6
89
90
91
Q70X5
Q84X5
S6400
92DB-1
771P Series
93
DB-2 93
DB-2
94FAB
95YA-6
96YA-7
109BY-14-101
Table of Contents - Alpha
Table of Contents - Numeric
H2F
H3
H3F
B3G
H3G
BM3
L3V
L6B
L6C
L6D
L6D21
L6E
B6E
H6E
L6E3
B6E3
L6F
B6F
H6F
L6G
B6G
H6G
H6G5
L6H5
L6J
L6J1
L6L
L6N
B6N
L6Q
B6Q
L6T
L6W
38
39
40
BM6A
BM6E
BM6G
41
42
43
HM8
H8C
HM8C
44
45
46
B8D
BM8D
H8H
47
48
49
50
51
BM8H
H8Q
B8Q
B9B1
HM9B
52
55
56
53
54
57
58
59
60
61
62
63
65
64
66
67
68
69
70
71
72
B9C
H9C
HM9C
B9D
H9D
B9E
HM9E
B9F
B9H
H9H
B9N
H9N
BM11
HM11
BM14A
BM14C
HM14C
BM14D
BM14G
HM14H
BM14K
Accessories
97
97
98
98
99
100
100
101
101
102
102
HL-3-001
HL-3-002
HL-3-003
HL-3-004
HL-3-005
HJ-8-201
BJ-8-202
HJ-8-203
BJ-8-205
BJ-8-206
BJ-8-207
103HJ-8-213
103
104
104
105
105
106
BJ-8-215
HJ-8-216
HJ-8-217
HJ-8-218
BJ-8-219
BJ-8-220
106
107
107
HD-8-301
HY-8-101
HY-8-102
108BY-8-104
108BY-8-106
111
112
HY-14-104
BY-14-105
110
111
BY-14-102
BY-14-103
Junction box
133
134
135
136
137
JB01
JB02
JB05A
JB06
JB07
Transmitter
138
139
140
FD-3
FD-4
FD-5
5BM24R
Miniature Sensors
73
74
75
76
78
79
80
81
82
1A
1B
IF6-S
1HM
1R1-K
1V3-350
1X1
1Z
2A
83
84
85
2C1
2F
004-G
86
87
88
CF-1
Q45X10
Q45X6
89
90
91
Q70X5
Q84X5
S6400
92DB-1
771P Series
93DB-2 93DB-2
94FAB
95YA-6
96YA-7
109BY-14-101
H2F
H3
H3F
B3G
H3G
BM3
L3V
L6B
L6C
L6D
L6D21
L6E
B6E
H6E
L6E3
B6E3
L6F
B6F
H6F
L6G
B6G
H6G
H6G5
L6H5
L6J
L6J1
L6L
L6N
B6N
L6Q
B6Q
L6T
L6W
38
39
40
BM6A
BM6E
BM6G
41
42
43
HM8
H8C
HM8C
44
45
46
B8D
BM8D
H8H
47
48
49
50
51
BM8H
H8Q
B8Q
B9B1
HM9B
52
55
56
53
54
57
58
59
60
61
62
63
65
64
66
67
68
69
70
71
72
B9C
H9C
HM9C
B9D
H9D
B9E
HM9E
B9F
B9H
H9H
B9N
H9N
BM11
HM11
BM14A
BM14C
HM14C
BM14D
BM14G
HM14H
BM14K
Accessories
97
97
98
98
99
100
100
101
101
102
102
HL-3-001
HL-3-002
HL-3-003
HL-3-004
HL-3-005
HJ-8-201
BJ-8-202
HJ-8-203
BJ-8-205
BJ-8-206
BJ-8-207
103HJ-8-213
103
104
104
105
105
106
BJ-8-215
HJ-8-216
HJ-8-217
HJ-8-218
BJ-8-219
BJ-8-220
106
107
107
HD-8-301
HY-8-101
HY-8-102
108BY-8-104
108BY-8-106
111
112
HY-14-104
BY-14-105
110
111
BY-14-102
BY-14-103
Junction box
133
134
135
136
137
JB01
JB02
JB05A
JB06
JB07
Transmitter
138
139
140
FD-3
FD-4
FD-5
5BM24R
Miniature Sensors
73
74
75
76
78
79
80
81
82
1A
1B
IF6-S
1HM
1R1-K
1V3-350
1X1
1Z
2A
83
84
85
2C1
2F
004-G 86
87
88
CF-1
Q45X10
Q45X6
89
90
91
Q70X5
Q84X5
S6400
92DB-1
771P Series
93
DB-2 93
DB-2
94FAB
95YA-6
96YA-7
109BY-14-101
Table of Contents - Alpha
H2A
· Capacities:1MN~ 5MN
· Alloy steel construction
· High reliability and long life span
MN 1/2/3/4/5
G2
0.2%
0.05%
0.1%
0.1%
≥2.0
1072±5
1050±5
≥5000(50VDC)
1.0
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
Wiring:
hielded, 4 conductor cable: Φ5mm
Standard cable length: 5m
S
Capacity(MN)
Dimension
D
D1
D2
H
H1
1 2 3 4 5
41
(1.61)
60
(2.36)
73
(2.87)
92
(3.62)
115
(4.53)
260
(10.24)
290
(11.42)
330
(12.99)
400
(15.75)
400
(15.75)
200
(7.87)
225
(8.86)
251
(9.88)
296
(11.65)
307
(12.09)
80
(3.15)
104
(4.09)
123
(4.84)
132
(5.20)
132
(5.20)
10
(0.39)
10
(0.39)
10
(0.39)
10
(0.39)
10
(0.39)
Specifications
ΦD 4-M16 depth 20(0.79)
Equipartion
H
ΦD1
ΦD2
H1
10(0.39)
1
· H2A load cells are available in the manifold accurate
measurement in the capacities 1MN to 5MN.
· Alloy steel,surface bluing treatment, spray painted,
oil-proof, waterproof and anti-corrosion, suitable for
groundsill measuring and other engineering
measuring fields.
· Spoke type, easy installation, suitable for special
force measuring equipments.
· Safety and anti-explosive product, can be used in
atrocious environments and hazardous areas.
Capacity
Accuracy
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
Outline Dimension mm(inch)
Features
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
G3
0.3%
0.05%
0.2%
0.2%
Outline Dimension mm(inch)
H2D
· H2D load cells are available for manifold
accurate measurement in the capacities 5t~ 20t.
· Alloy steel, sealed by adhesive, oil-proof,
waterproof and anti-corrosion, suitable for
all kinds of environments.
· Spoke type, easy installation, suitable for
crane scale, hopper scale and other electronic
weighing devices.
· Safe and anti-explosive product, can be used in
atrocious environment and hazardous areas.
· Capacity: 5t~ 20t
· Alloy steel construction
· High accuracy
5/10/20
C2
2000
Emax/5000
≤±0.030
≤±0.023
≤±0.017
≤±0.029
2.0±0.008
750±10
700±7
≥5000(50VDC)
1.0
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
Wiring:
Five-wire connector
hielded, 4 conductor cable: Φ5mm
Standard cable length: 5m(5t,10t),10m(20t)
S
D D1 M H
Capacityt()
Dimension
(mm)
5
10
20
L
83
(3.27)
128
(5.04)
45
(1.77) M24×2
8
(0.31)
150
(5.91)
160
(6.03)
60
(2.36) M39×2 30
(1.18)
220
(8.66)
200
(7.78)
80
(2.99) M60×2 60
(2.36)
t
Specifications
M
25
(0.98)
L
H
52
(2.05)
ΦD
ΦD1
2
Capacity
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
nmax
vmin
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
Features
CANADA
TEL: 416-213-9900
WWW.BRECKNELLSCALES.CA
INDIA
TEL: +91 129 4159774/75/76
WWW.SALTERINDIA.COM
HM2D4
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
tCapacity
C3
2000
Emax/5000
≤±0.030
≤±0.024
≤±0.017
≤±0.023
2.0±0.002
350±3
351±2
≥5000(50VDC)
1.0
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
Features
· Capacity: 0.5t~ 50t
· High accuracy
· Alloy steel construction
· Low profile
Outline Dimension mm(inch)
Wiring:
Shielded, 6 conductor cable: Φ5.6mm
Standard cable length: 5m
·
·
·
HM2D4 load cells are available for manifold
accurate measurement in the capacities 0.5t~ 20t.
Alloy steel, completely welded, oil-proof,
waterproof and anti-corrosive gas and medium,
suitable for all kinds of environments.
Spoke type, suitable for electronic truck scales,
hopper scales, automotive testing equipments,
and other electronic weighing or force measuring fields.
0.5/1/2/3/5/10/20/50
Output (+) White
Sense (-) Blue
Output (-) Red
Input (+) Green
Input (-) Black
Sense (+) Yellow
0.5t~2t
D
105
(4.13)
28
(1.10)
70
(2.76)
Dimension
(mm)
Capacity(t)
3t,5t
10t,20t
D1 H M
120
(4.72)
155
(6.10)
33
(1.3)
60.5
(2.38)
90
(3.54)
80
(3.15)
M14×2
M20×1.5
M32×2
IP68
50
(1.97)
ΦD1
25
(0.98)
30
(0.18)
H
ΦD
M
Specifications
3
nmax
vmin
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
50t 200
(7.87)
75
(2.95)
120
(4.72) M45×3
H2F
· H2F load cells are available for manifold accurate
measurement in the capacities 1t~ 50t.
· Alloy steel, potted with adhesive inside, oil-proof,
waterproof and anti-corrosion, suitable for all kinds
of environments.
· Spoke type, easy installation, suitable for
electronic truck scales, hopper scales and other
electronic weighing devices.
· Safe and anti-explosive product, can be used in
atrocious environment and hazardous areas.
Features
· Capacity: 1t~ 50t
· Alloy steel construction
· High accuracy
C1
1000
Emax/3000
≤±0.050
≤±0.038
≤±0.028
≤±0.047
C2
2000
Emax/5000
≤±0.030
≤±0.023
≤±0.017
≤±0.029
2.0±0.01
770±30
700±5
≥5000(50VDC)
1.5
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
Output (+) Blue
Sense (-) Black
Output (-) White
Input (+) Red
Input (-) Yellow
Sense (+) Brown
Wiring:
hielded, 6 conductor cable: Φ6mm
Standard cable length: 3m(1~3t),4m(5~10t),15m(15~50t)
S
Capacity(t)
Dimension(mm)
Capacity
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
t
Specifications
D D1 D2 H H1 H2 WL
1
2
3
5
10
15
20
30
50
115
(4.53)
22
(0.87)
86
(3.39)
43
(1.69)
12
(0.47)
5
(0.2)
8
(0.31)
8.4
(0.33)
120
(4.72)
26
(1.02)
128
(5.04)
160
(6.3)
128
(5.04)
194
(7.64)
220
(8.66)
230
(9.06)
264
(10.39)
20
(0.79)
20
(0.79)
40
(1.57)
42
(1.65)
44
(1.73)
48
(1.89)
52
(2.05)
90
(3.54)
100
(3.94)
100
(3.94)
120
(4.72)
154
(6.06)
170
(6.69)
188
(7.4)
214
(8.43)
45
(1.77)
46
(1.81)
63
(2.48)
73
(2.87)
78
(3.07)
90
(3.54)
68
(2.68)
46
(1.81)
12
(0.47)
8
(0.31)
8
(0.31)
15
(0.59)
20
(0.79)
22
(0.87)
25
(0.98)
30
(1.18)
5
(0.2)
5
(0.2)
10
(0.39)
10
(0.39)
10
(0.39)
10
(0.39)
10
(0.39)
5
(0.2)
8
(0.31)
7
(0.28)
7
(0.28)
10
(0.39)
12
(0.47)
12
(0.47)
12
(0.47)
12
(0.47)
8.4
(0.33)
10.4
(0.41)
10.4
(0.41)
10.4
(0.41)
12.4
(0.49)
12.4
(0.49)
12.4
(0.49)
12.4
(0.49)
Accessory
· HM-2-401
· BM-2-402
ΦD2
H2
ΦD
H1
4-W
4-L
45° 45°
ΦD1
4
nmax
vmin
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
Outline Dimension mm(inch)
CANADA
TEL: 416-213-9900
WWW.BRECKNELLSCALES.CA
INDIA
TEL: +91 129 4159774/75/76
WWW.SALTERINDIA.COM
H
1/2/3/5/10/15/20/30/50
·
·
hazardous
BM24R applied a ring type, suitable for all kinds of
platform scales and dynamic weighing system.
Stainless steel, Hermetically sealed IP68,low profile
load cell for all kinds of applications.
Features
· Capacity: 60kg-60t
High accuracy
OIML Cert. No.: R60/2000-NL-11.21
NTEP Cert. No.: 11-103A1
·
·
·
BM24R
BM24R 60kg-280kg
Accessory: BJ-24-202
BM-24-401
BM24R 250kg-13t
BJ-24-203 BJ-24-204
BM-24-402 BM-24-403
BM24R-28t-60t
BJ-24-205
Capacity
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
C3
3000
Emax/10000
≤±0.0230
≤±0.0245
≤±0.0117
≤±0.0140
Specifications
60kg / 130kg / 250kg / 280kg / 500kg / 1t / 2t / 3.5t / 5t/ 10t / 13t / 28t / 60t
nmax
vmin
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(%FS)
60kg / 130kg /
280kg
1.0±0.1
250kg
1.75±0.1 2.0±0.1
60kg / 130kg /
280kg
1260±100
500kg 60t~
250kg /
500kg 10t~
1100±100
13t
1200±100
28t 60t
1075±100 1350±100
60kg / 130kg /
280kg
1020±0.5
250kg /
500kg 10t~ 13t 28t 60t
1025±25 1000±0.5 930±0.5 1175±0.5
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
≥5000(50VDC)
1.0
-10 +40~
-30 +70~
5 12(DC)~
15(DC)
150
300
Nm
60kg / 130kg /
280kg
8
250kg /
500kg 10t~ 13t 28t 60t
10 - - -
Recommended torque on
fixation bolts
Protection class IP68
Outline Dimension mm(inch)
Wiring:
S
±
hielded, 4 conductor cable:
Φ6.2mm 0.1mm
Dim.
Capacity
ΦA ΦB C D E ΦF G H I J ΦK SR
60kg /
130kg /
280kg
63 15.1 22 11 60 54 6 10 Φ3.2 -- -- --
0.25t/0.5t/1t 80 19 25 12.5 65 71 10 18 M10 1 25 --
2t / 3.5t 80 19 30 12.5 65 71 10 18 Φ15 6 25 --
10t 95 26 35 12.5 72 75 20.7 31.2 -- -- 29 --
13t 95 26 35 20 85 79.5 20 31 -- -- 29 --
28t 120 35.9 46 25 94 102 -- 53 -- -- -- 400
60t 140 47.9 62 34 104 124 -- 69 -- -- -- 600
Capacity Cable length
60kg
3m
130kg
250kg
280kg
500kg
1t
2t
6m3.5t
5t
10t
15m
13t
28t
60t
5
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
To order call (919) 776-7737 or visit www.CentralCarolinaScale.com
25kg-5t
L
2-M
H
W1
0.1-20klb
H1
2Places
7.5t-30t
L
2-M
H
H1
2Places
H3
Accuracy
Approvals
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
t
lb
Capacity
25kg/50kg/100kg/150kg/200kg/250kg/300kg/500kg/600kg/750kg/1t/1.5t/2t/2.5t/3t/5t/7.5t/10t/15t/20t/30t
100/150/200/250/300/500/750/1K/1.5K/2K/2.5K/3K/5K/10K/15K/20K
C3
OIML R60 C3
3000
Emax/10000
≤±0.020
≤±0.016
≤±0.011
≤±0.015
N10
10000
Emax/10000
≤±0.20
≤±0.020
≤±0.014
≤±0.017
2.0±0.004(Metric) 3.0±0.008(Imperial)
350±3.5
351±2.0
≥5000(50VDC)
1.5(Metric) 1.0(Imperial)
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
· H3 load cells are available in the capacities
25kg~ 30t and 100lb~ 20Klb.
· Alloy steel, sealed by adhesive inside, oil-proof, waterproof
and anti-corrosion, suitable for all kinds of environments.
· S beam design, tension and/or compression loading possible,
easy installation, suitable for crane scale, mechanical
conversion scale, hopper scale and other electronic weighing
devices.
· Safe and anti-explosive product, can be used in
atrocious environment and hazardous areas.
Features
· Capacity: 25kg~ 30t ; 100lb~ 20Klb
· High accuracy
· Alloy steel construction
· Low profile
· OIML Certificates No:R60/2000-CN-00.01
· PTB Approval No:D09-03.18 Revision 2
· NTEP Certificates No:CC06-099A1
Accessory
· HL-3-001 · HL-3-002
· HL-3-003 · HL-3-004· HL-3-005
Specifications
Outline Dimension mm(inch)
Wiring:
Shielded, 4 conductor cable: Φ5mm
Standard cable length: 3m(0.025t~0.75t),
6m(1t~30t)(0.1klb~20klb)
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
W1 W MCapacity
Dimension(mm)
H1±0.4
25kg~50kg
0.1t~0.15t
0.2t~0.75t
1t~1.5t
2t~5t
7.5t~10t
15t~20t
30t
100lb~300lb
500lb
0.75klb~1.5klb
2klb~2.5klb
3klb
5klb~10klb
15klb
20klb
15.7(0.62)
10.16(0.4)
15.3(0.60)
15.3(0.60)
12.1(0.48)
76.2(3.0)
76.2(3.0)
76.2(3.0)
76.2(3.0)
101.6(4.0)
175(6.89)
200(7.89)
230(9.06)
63.5(2.5)
63.5(2.5)
63.5(2.5)
63.5(2.5)
101.6(4.0)
101.6(4.0)
139.7(5.5)
177.8(7.0)
50.8(2.0)
50.8(2.0)
50.8(2.0)
50.8(2.0)
76.2(3.0)
125(4.92)
160(6.3)
190(7.48)
50.8(2.0)
50.8(2.0)
50.8(2.0)
50.8(2.0)
76.2(3.0)
76.2(3.0)
101.6(4.0)
127(5.0)
12.7(0.5)
19.0(0.75)
19.0(0.75)
25.4(1.0)
25.4(1.0)
50(1.97)
60(2.36)
80(3.15)
12.7(0.5)
19.05(0.75)
19.05(0.75)
25.4(1.0)
25.4(1.0)
25.4(1.0)
31.75(1.25)
50.8(2.0)
16.1(0.63)
22.4(0.88)
22.4(0.88)
28.8(1.13)
28.8(1.13)
/
/
/
15.9(0.63)
22.25(0.88)
22.25(0.88)
28.6(1.13)
28.6(1.13)
28.6(1.13)
34.95(1.38)
54(2.13)
M8
M10×1.5
M10×1.5
M12×1.75
M20×1.5
M33×3
M42×3
M42×3
1/4-28UNF
1/2-20UNF
1/2-20UNF
1/2-20UNF
1/2-20UNF
3/4-16UNF
1-14UNS
20(0.79)
40.2(1.58)
51(2.01)
57.5(2.26)
15.24(0.6)
31(1.22)
39.9(1.57)
15.24(0.6)
W
W1
5
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
nmax
vmin
H L
6
CANADA
TEL: 416-213-9900
WWW.BRECKNELLSCALES.CA
INDIA
TEL: +91 129 4159774/75/76
WWW.SALTERINDIA.COM
Central Carolina Scale, Inc
5393 Farrell Road
Sanford NC 27330
PH: 919-776-7737
www.CentralCarolinaScale.com
H3F
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
t
lb
Capacity
C3
3000
Emax/10000
≤±0.020
≤±0.016
≤±0.011
≤±0.015
N5
5000
Emax/5000
≤±0.020
≤±0.020
≤±0.017
≤±0.020
3.0±0.008
350±3.5
351±2.0
≥5000(50VDC)
1.0
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
· H3F load cells are available in the capacities
0.1t~ 5t and 250lb~ 20Klb.
· Alloy steel, sealed by adhesive inside, oil-proof,
waterproof and anti-corrosion, suitable for all
kinds of environments.
· S beam design, tension and/or compression loading
possible, easy installation, suitable for crane scale,
mechanical conversion scale, hopper scale and other
electronic weighing devices.
· Safe and anti-explosive product, can be used in
atrocious environment and hazardous areas.
Features
· Capacity: 0.1t~ 5t;250lb~ 20Klb
· High accuracy
· Alloy steel construction
· Low profile
· NTEP Certificates No:CC06-099A1
Accessory
· HL-3-001 · HL-3-002
· HL-3-003 · HL-3-004· HL-3-005
Specifications
Outline Dimension mm(inch)
100kg/250kg/500kg/750kg/1t/1.5t/2t/2.5t/5t
250/500/750/1K/1.5K/2K/2.5K/3K/5K/7.5K/10K/15K/20K
Capacity
Dimension
mm
100kg
250kg
500kg
750kg
1000kg
1500kg
2000kg
2500kg
5000kg
250lb
500lb
750lb
1klb
1.5klb
2klb
2.5klb
3klb
5klb
7.5klb
10klb
15klb
20klb
76.2(3)
76.2(3)
76.2(3)
76.2(3)
76.2(3)
76.2(3)
108(4.25)
108(4.25)
108(4.25)
76.2(3)
76.2(3)
76.2(3)
76.2(3)
76.2(3)
76.2(3)
76.2(3)
76.2(3)
108(4.25)
108(4.25)
108(4.25)
140(5.51)
177.8(7)
25.4(1.0)
25.4(1.0)
25.4(1.0)
25.4(1.0)
31.8(1.25)
31.8(1.25)
31.8(1.25)
31.8(1.25)
31.8(1.25)
19(0.75)
25.4(1.0)
25.4(1.0)
25.4(1.0)
25.4(1.0)
31.8(1.25)
31.8(1.25)
31.8(1.25)
31.8(1.25)
31.8(1.25)
31.8(1.25)
38.1(1.31)
50.8(2.0)
19(0.75)
19(0.75)
19(0.75)
19(0.75)
25.4(1)
25.4(1)
25.4(1)
25.4(1)
25.4(1)
12.7(0.5)
19(0.75)
19(0.75)
19(0.75)
19(0.75)
25.4(1)
25.4(1)
25.4(1)
25.4(1)
25.4(1)
25.4(1)
31.8(1.25)
49.3(1.94)
50.8(2)
50.8(2)
50.8(2)
50.8(2)
50.8(2)
50.8(2)
76.2(3)
76.2(3)
76.2(3)
50.8(2)
50.8(2)
50.8(2)
50.8(2)
50.8(2)
50.8(2)
50.8(2)
50.8(2)
76.2(3)
76.2(3)
76.2(3)
100(3.94)
125.5(4.94)
15.8(0.62)
15.12(0.6)
14.2(0.56)
13.46(0.53)
13.24(0.52)
12.1(0.48)
26.7(1.05)
25.48(1)
20.26(0.8)
15.69(0.62)
15.25(0.6)
14.95(0.59)
14.4(0.57)
13.75(0.54)
13.4(0.53)
13.03(0.51)
12.39(0.49)
27.18(1.07)
25.78(1.01)
23.88(0.94)
31(1.22)
39.9(1.57)
M10×1.5
M12×1.75
M12×1.75
M12×1.75
M12×1.75
M12×1.75
M18×1.5
M18×1.5
M18×1.5
3/8-24UNF-2B
1/2-20UNF-2B
1/2-20UNF-2B
1/2-20UNF-2B
1/2-20UNF-2B
1/2-20UNF-2B
1/2-20UNF-2B
1/2-20UNF-2B
3/4-16UNF-2B
3/4-16UNF-2B
3/4-16UNF-2B
1-14UNS-2B
1-1/4-12UNF-2B
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
Shielded, 4 conductor cable: Φ5mm
Standard cable length: 6m
Wiring:
H W W1 L H1 MW1
H
2-M-6H
L
H1
(2Places)
W
nmax
vmin
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
7
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
B3G
t
lb
Capacity
C3
OIMLR60 C3
3000
Emax/10000
≤±0.020
≤±0.016
≤±0.011
≤±0.015
N3
3000
Emax/3000
≤±0.030
≤±0.030
≤±0.020
≤±0.025
3.0±0.008
430±60
351±2.0
≥5000(50VDC)
1.0
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
Features
· Capacity:50kg~ 10t ;50lb~ 20Klb
·
·
·
· R60/2000-CNI-06.02
· D09-06.07
· NTEP Certificates No:CC06-099A1
High accuracy
Stainless steel construction
Low profile
OIML Certificates No:
PTB Approval No:
Accessory
· HL-3-001 · HL-3-002
· HL-3-003 · HL-3-004· HL-3-005
Specifications
Outline Dimension mm(inch)
Wiring:
Shielded, 4 conductor cable: Φ5mm
Standard cable length: 6m
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
50kg/100kg/250kg/500kg/1t/2.5t/5t/7.5t/10t
50/75/100/150/200/250/300/500/750/1K/1.5K/2K/2.5K/3K/5K/10K/15K/20K
· B3G load cells are available in the capacities
50kg~ 10t and 50lb~ 20Klb.
· Stainless steel, sealed by adhesive inside, oil-proof, waterproof
and anti-corrosion, suitable for all kinds of environments.
· S beam design, tension and/or compression loading possible,
easy installation, suitable for crane scale,mechanical conversion
scale, hopper scale and other electronic weighing devices.
· Safe and anti-explosive product, can be used in atrocious
environment and hazardous areas.
50.8
(2.0)
11.68
(0.46)
15.06
(0.59)
50.8
(2.0)
18.03
(0.71)
21.4
(0.84)
50.8
(2.0)
24.38
(0.96)
27.76
(1.09)
Dimension
mm
M8
1/4-28UNF
74.68
(2.94)
87.38
(3.44)
37.08
(1.46)
40.46
(1.59)
112.78
(4.44)
42.93
(1.69)
46.31
(1.82)
M12
1/2-20UNF
M12
1/2-20UNF
M20×1.5
1/2-20UNF
M20×1.5
3/4-16UNF
M24×2
1-14UNS
60.96
(2.4)
139.7
(5.5)
177.8
(7.0)
99.06
(3.9)
30.74
(1.21)
34.12
(1.34)
Capacity
L H WW1 M H1
50kg,100kg
50lb~300lb
250kg,500kg
500lb~1.5 lb
1t
2,2.5klb
2.5t
3klb
5t
10klb
7.5t
15klb
10t
20klb
k
76.2
(3.0)
5klb 76.2
(3.0)
60.96
(2.4)
60.96
(2.4)
99.06
(3.9)
99.06
(3.9)
24.38
(0.96)
24.38
(0.96)
27.76
(1.09)
27.76
(1.09)
M30×2
-12UNS1-1
4
3/4-16UNF
8.89
(0.35)
13.97
(0.55)
18.37(0.72)
15.75(0.62)
27.5
(1.08)
39.9
(1.57)
13.97
(0.55)
W2-M
L
H
H1
2Places
W1
7
nmax
vmin
Accuracy
Approvals
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
8
CANADA
TEL: 416-213-9900
WWW.BRECKNELLSCALES.CA
INDIA
TEL: +91 129 4159774/75/76
WWW.SALTERINDIA.COM
N10
10000
Emax/10000
≤±0.020
≤±0.020
≤±0.014
≤±0.017
H
2-M
L
H1
2Places
W
H3G
Features
· Capacity: 50kg~ 10t ; 50lb~ 20Klb
· High accuracy
· Alloy steel construction
· Low profile
· NTEP Certificates No:CC06-099A1
· OIML Certificates No:R60/2000-NL1-10.30
Accessory
· HL-3-001 · HL-3-002
· HL-3-003 · HL-3-004· HL-3-005
Outline Dimension mm(inch)
Wiring:
Shielded, 4 conductor cable: Φ5mm
Standard cable length: 6m
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
· H3G load cells are available in the capacities
50kg~ 7.5t and 50lb~ 20Klb.
· Alloy steel, sealed by adhesive inside, oil-proof, waterproof
and anti-corrosion, suitable for all kinds of environments.
· S beam design, tension and/or compression loading possible,
easy installation, suitable for crane scale,mechanical
conversion scale, hopper scale and other electronic weighing
devices.
· Safe and anti-explosive product, can be used in atrocious
environment and hazardous areas.
50.8
(2.0)
12.7
(0.5)
16.07
(0.63)
50.8
(2.0)
19.05
(0.75)
22.43
(0.88)
50.8
(2.0)
25.4
(1.0)
28.78
(1.13)
Dimension
mm
M8
1/4-28UNF
101.6
(4.0)
31.75
(1.25)
35.13
(1.38)
127
(5.0)
50.8
(2.0)
54.6
(2.15)
M12
1/2-20UNF
M12
1/2-20UNF
M20×1.5
1/2-20UNF
M20×1.5
3/4-16UNF
M24×2
1-14UNS
63.5
(2.5)
139.7
(5.5)
177.8
(7.0)
25.4
(1.0)
Capacity
L H WW1 M H1
50kg,100kg
50lb~300lb
200kg,500kg
500lb~1.5klb
1t
2,2.5klb
2.5t
3klb
5t
5klb,10klb
7.5t
15klb
76.2
(3.0)
25.4
(1.0)
-12UNF1-1
4
10.16
(0.4)
15.2
(0.6)
20(0.79)
15.24(0.6)
39.9
(1.57)
76.2
(3.0)
63.5
(2.5)
63.5
(2.5)
101.6
(4.0)
101.6
(4.0)
28.78
(1.13)
28.78
(1.13)
20klb
30(1.18)
31(1.22)
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
t
lb
Capacity
C3
3000
Emax/10000
≤±0.020
≤±0.016
≤±0.011
≤±0.015
N3
3000
Emax/3000
≤±0.030
≤±0.030
≤±0.020
≤±0.025
3.0±0.008
430±60
351±2.0
≥5000(50VDC)
1.0
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
Specifications
0.05/0.1/0.25/0.5/1/2.5/5/7.5
50/75/100/150/200/250/300/500/750/1K/1.5K/2K/2.5K/3K/5K/10K/15K/20K
W1
8
nmax
vmin
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
9
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
N10
10000
Emax/10000
≤±0.020
≤±0.020
≤±0.014
≤±0.017
W
86
92(3.62)
Φ99
2-M-6H
Features
· Capacity:1t~ 7.5t
· High accuracy
· Stainless steel construction
· Low profile
· PTB Approval NO:D09-08.01
· NTEP Certificates No:CC06-099A1
Accessory
· HL-3-001 · HL-3-002
· HL-3-003 · HL-3-004· HL-3-005
Outline Dimension mm(inch)
Wiring:
Shielded, 4 conductor cable: Φ5mm
Standard cable length: 3m(500kg), 6m(1t~7.5t)
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
· Bm3 load cells are available in the capacities 1t~ 7.5t.
· Stainless steel, hermetically welded, oil-proof, waterproof and
anti-corrosion, suitable for all kinds of environments.
· S beam design, tension and/or compression loading possible,
easy installation, suitable for electronic crane scale, hopper
scale and other electronic weighing devices.
· Safe and anti-explosive product, can be used in atrocious
environment and hazardous areas.
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
tCapacity
C3
3000
Emax/10000
≤±0.020
≤±0.016
≤±0.011
≤±0.015
2.0±0.004
350±3.5
351±2.0
≥5000(50VDC)
1.5
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
Specifications
1/2/3/4/5/6
W 32(1.26) 32(1.26) 32(1.26)
Dimension(mm)
36(1.42) 50(1.97) 50(1.97)
M
H
Capacity (t)
1.0 2.0-2.5t 3.0 4.0 5.0 6.0
M20×1.5 M20×1.5 M20×1.5 M24×2 M24×2M12×1.75
25(0.98)25(0.98) 25(0.98) 25(0.98) 24(0.94)24(0.94)
BM3
H
2Places
nmax
vmin
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
Approvals OIML R60 C3
(3.90)
(3.39)
10
CANADA
TEL: 416-213-9900
WWW.BRECKNELLSCALES.CA
INDIA
TEL: +91 129 4159774/75/76
WWW.SALTERINDIA.COM
L3V
Features
· Capacity: 200kg~500kg
· Aluminum S beam
· High accuracy
· High reliability
kg
· L3V load cells are available in the capacities 200kg and 500kg.
· Aluminum material, sealed with silicon adhesive,
surface spraying plastic with good resistance against
corrosion.
· Integral construction, easy installation.
· Suitable for textile machinery measuring and other electronic
measuring fields.
Wiring:
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
Shielded, 4 conductor cable: Φ5.3±0.2mm,
and cable jacket is PVC.
Standard cable length: 2.6±0.1m
IP65
200/500
C2
2000
Emax/5000
≤±0.030
≤±0.024
≤±0.03
≤±0.5
2.3±0.2
410±30
351±2
≥5000(50VDC)
2
-10~ +40
-35~ +65
5~ 12(DC)
18(DC)
120
150
64(2.52)
80(3.15)
25(0.98)
2-M12
15
(0.59)
15
(0.59)
Capacity
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Specifications
102
nmax
vmin
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
Outline Dimension mm(inch)
11
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
L6B
Features
· Capacity: 0.3kg~ 3kg
· High accuracy
· Max. platform size: 200×200mm
·
0.3kg~ 3kg.
· Aluminum construction with parallel beam.
· Silicon adhesive sealed, surface anodized
and anti-corrosion.
· Integral structure and easy installation.
· Suitable for electronic balance and other
electronic weighing devices.
L6B load cells are available in the capacities
Wiring:
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
Shielded, 4 conductor cable, and cable
jacket is PVC.
Cable length: 0.45±0.05m
Cable diameter: 3±0.2mm
7(0.28)
2 Places
5(0.20)
2 Places
33(1.30)
4-M3 Depth 10(0.39)
10(0.39)
17(0.67)17(0.67)
110(4.33)
IP65
11
Capacity
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
C3
≤±0.030
0.9±0.1
406±6
350±3
≥5000(50VDC)
2
-10~ +40
-35~ +65
5~ 12(DC)
18(DC)
120
150
2500
Emax/5000
≤±0.020
≤±0.021
≤±0.028
Specifications
0.3/0.6/1.2/3
0.02% /100mmload value
nmax
vmin
Outline Dimension mm(inch)
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
Underport Depth 15(0.38)
12
CANADA
TEL: 416-213-9900
WWW.BRECKNELLSCALES.CA
INDIA
TEL: +91 129 4159774/75/76
WWW.SALTERINDIA.COM
Outline Dimension mm(inch)
L6C
Features
· Capacity: 3kg~ 50kg
· High accuracy
· Max. platform size: 450×450mm
· Installed screw request M8, 8.8 class,
with oiled screw, torque 25Nm.
Capacity
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
C3D
≤±0.030
2500
Emax/5000
≤±0.020
≤±0.021
≤±0.028
Specifications
· L6C load cells are available in the capacities
3kg~ 50kg.
· Aluminum construction with parallel beam.
· Silicon adhesive sealed, surface anodized
and anti-corrosion.
· Integral structure and easy installation.
· Suitable for pricing scale, counting scale, electronic
balance and other electronic weighing devices.
Wiring:
406±6
350±3
≥5000(50VDC)
2
-10~ +40
-35~ +65
5~ 12(DC)
18(DC)
120
150
0.02% /100mmload value
3/5/8/20/30/50
Input (+)
Shield
Output (-)
Input (-)
Output (+)
Shielded, 5 conductor ribbon cable.
Cable length: 0.35±0.05m
The shield is connected to the element.
IP65
2-M8-6H Through
125(4.92)
45(1.77)
29(1.14)
24(0.94)
45(1.77)
27
(1.06)
8
(0.31)
2-M8 Depth 15(0.59)
2 Places
Limiting plate
2
nmax
vmin
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
1.9±0.2
13
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
L6D
Features
· Capacity: 2.5kg~ 50kg
· High accuracy
· Max. platform size: 250×350mm
· OIML Certificates No:R60/2000-CN-00.05 Revision 1
· PTB Approval No:D09-03.20 Revision 1
· NTEP Certificates N0: CC 11-012
Capacity
Accuracy
Approvals
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
C3
OIML R60 C3
3000
Emax/7000
≤±0.020
≤±0.0167
≤±0.0175
≤±0.020
2.0±0.2
406±6/1065±15
350±3/1000±10
≥5000(50VDC)
2
-10~ +40
-35~ +65
5~ 12(DC)
18(DC)
120
150
0.02%load value/100mm
Specifications
· L6D load cells are available in the capacities
2.5kg~ 50kg.
· Aluminum construction with parallel beam.
· Silicon adhesive sealed, surface anodized
and anti-corrosion.
· Integral structure and easy installation.
· Suitable for pricing scale, platform scale and other
electronic weighing devices.
2.5/3/5/6/8/10/15/20/30/35/40/50
Output
resistance
Input Output
+ +- -
R
R
W
B G
G
W
B1000(Ω)
Wiring:
Shield
Transparent
350(Ω)
hielded, 4 conductor cable, and cable
jacket is PVC.
Cable length: 0.40±0.05m
Cable diameter: 3.8±0.2mm
S
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
IP65
15(0.59)
25(0.98)
2 Places
301.18()
130(5.21)
22(0.87)
2Places
2 Places
12(0.47)
4-M6-6H Through
Outline Dimension mm(inch)
nmax
vmin
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
14
CANADA
TEL: 416-213-9900
WWW.BRECKNELLSCALES.CA
INDIA
TEL: +91 129 4159774/75/76
WWW.SALTERINDIA.COM
Outline Dimension mm(inch)
L6D21
Features
· Capacity: 3kg~ 50kg
· Excellent waterproof ability
· High accuracy
· Max. platform size: 250×350mm
· L6D21 load cells are available in the capacities
3kg~ 50kg.
· Aluminum construction with parallel beam.
· Special sealing techniques and surface anodized
makes waterproof and anti-corrosion.
· Integral structure and easy installation.
· Suitable for pricing scales, platform scales and
other electronic weighing devices which has high
requirements for waterproof ability.
Wiring:
Shielded, 4 conductor cable,
and cable jacket is PVC.
Cable length: 4m
Cable diameter: 3.8±0.2mm
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
Capacity
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
C3
3000
Emax/7000
≤±0.020
≤±0.0167
≤±0.0175
≤±0.020
2.0±0.2
409±6
350±3
≥5000(50VDC)
2
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
0.02%load value/100mm
Specifications
3/6/10/15/20/30/40/50
IP68
15(0.59)
2Places22
(0.87)
106
(4.17)
30
(1.18)
130
(5.12)
4-M6-6H
Through
nmax
vmin
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
15
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
40(1.57)
150(5.91)
33(1.30)
4 Places
35(1.38)
7(0.28) 19(0.75)
8-M8-6H Depth 20(0.79)
Through hole
15(0.59)
19(0.75)
19(0.75) 7(0.28)
Outline Dimension mm(inch)
L6E
Features
· Capacity: 50kg~ 300kg
· High accuracy
· Max. platform size: 400×400mm
· OIML Certificates No:R60/2000-CN-00.04 Revision 1
· PTB Approval No:D09-03.21 Revision 1
· NTEP Certificates No: CC:11-062
Capacity
Accuracy
Approvals
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
C3
OIML R60 C3
3000
Emax/7000
≤±0.020
≤±0.0167
≤±0.0175
≤±0.020
2.0±0.2
406±6
350±3
≥5000(50VDC)
2
-10~ +40
-35~ +65
5~ 12(DC)
18(DC)
120
150
0.02%load value/100mm
Specifications
· L6E load cells are available in the capacities
50kg~ 300kg.
· Aluminum construction with parallel beam.
· Silicon adhesive sealed, surface anodized
and anti-corrosion.
· Integral structure and easy installation.
· Suitable for pricing scales, platform scales and other
electronic weighing devices.
Wiring:
hielded, 4 conductor cable,
and cable jacket is PVC.
Cable length: 2±0.1m
Cable diameter: 5.3±0.2mm
S
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
IP65
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
nmax
vmin
8-M8-6H Depth 20(0.79)
Depth 24
16
CANADA
TEL: 416-213-9900
WWW.BRECKNELLSCALES.CA
INDIA
TEL: +91 129 4159774/75/76
WWW.SALTERINDIA.COM
50/60/80/100/150/200/300
B6E
Outline Dimension mm(inch)
Wiring:
Shielded, 4 conductor cable:Φ5mm
Standard cable length: 2m
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
· B6E load cells are available in the capacities
100kg~ 300kg.
· 17-4PH stainless steel construction, potted
by adhesive inside, oil proof, waterproof,
anti-corrosive gas and medium making it
suitable for all kinds of environments.
· Single point with parallel beam, suitable
for electronic scales, platform scales, belt
scales and other electronic weighing devices.
· Recommended platform size: 400×400mm
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
Capacity
C3
3000
Emax/10000
≤±0.020
≤±0.016
≤±0.011
≤±0.015
2.0±0.2/2.0±0.002
384±4/400±20
351±2.0
≥5000(50VDC)
1.5
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
0.02%load value/100mm
100/150/200/300
16.5(0.65)
8-M6-6H 15(0.59)Depth
35
(0.99)
15(0.59)
7(0.28)
Two ends
2-3
Two ends
Two ends
Twoends
Two ends
19(0.75)
150(5.91)
40(1.57)
38(1.50)
)
0
3
.
1
(
3
3
8
(0.31)
38
(1.50)
IP66
Specifications
2
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
nmax
vmin
Features
· Capacity: 100kg~ 300kg
· High accuracy
· Stainless steel construction
· Low profile and easy installation
17
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
Outline Dimension mm(inch)
H6E
Features
· Capacity: 100kg~ 300kg
· High accuracy
· Alloy
·
steel construction
Low profile and easy installation
Wiring:
Shielded, 4 conductor cable: Φ5mm
Standard cable length: 2m
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
· H6E load cells are available in the capacities
10 ~
· Alloy nickel plated,
·
· ×
0kg 300kg.
steel construction, potted
by adhesive inside, oil proof, waterproof,
anti-corrosive gas and medium making it
suitable for all kinds of environments.
Single point with parallel beam, suitable
for electronic scales, platform scales, belt
scales and other electronic weighing devices.
Recommended platform size: 400 400mm
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
Capacity
C3
3000
Emax/10000
≤±0.020
≤±0.016
≤±0.011
≤±0.015
2.0±0.2/2.0±0.002
384±4/400±20
351±2.0
≥5000(50VDC)
1.5
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
0.02%load value/100mm
Specifications
100/150/200/300
IP66
16.5(0.65)
8-M6-6H Depth 15(0.59)
35
(0.99)
15(0.59)
7(0.28)
Two ends
2-3
Two ends
Twoends
Two ends
19(0.75)
150(5.91)
40(1.57)
38(1.50)
)
0
3
.
1
(
3
3
8
(0.31)
38
(1.50)
17
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
nmax
vmin
Two ends
18
CANADA
TEL: 416-213-9900
WWW.BRECKNELLSCALES.CA
INDIA
TEL: +91 129 4159774/75/76
WWW.SALTERINDIA.COM
40(1.75)
2 Places
33(1.30)
2 Places
6(0.24)
150(5.91)
8-M6-6H Depth 20(0.79)
44(1.73)
30(1.18)
19(0.75)
2 Places
2Places
Outline Dimension mm(inch)
L6E3
Features
· Capacity: 50kg~ 300kg
· High accuracy
· Max. platform size: 450×450mm
· OIML Certificates No:R60/2000-CN1-06.08
· PTB Approval No: D09-06.09
· NTEP Certificates No: CC11-062
Capacity
Accuracy
Approvals
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
2.0±0.2
406±6
350±3
≥5000(50VDC)
2
-10~ +40
-35~ +65
5~ 12(DC)
18(DC)
120
150
0.02%load value/100mm
Specifications
· L6E3 load cells are available in the capacities
50kg~ 300kg.
· Aluminum construction with parallel beam.
· Silicon adhesive sealed, surface anodized
and anti-corrosion.
· Integral structure and easy installation.
· Suitable for electronic pricing scales, electronic
platform scales and other electronic weighing devices.
50/100/150/200/250/300
Wiring:
hielded, 4 conductor cable, and cable
jacket is PVC.
Cable length: 3±0.1m
Cable diameter: 5.3±0.2mm
S
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
IP65
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
C3
OIML R60 C3
3000
Emax/7000
≤±0.020
≤±0.0167
≤±0.0175
≤±0.020
nmax
vmin
Underport Depth 24(0.94)
19
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
Central Carolina Scale, Inc
5393 Farrell Road
Sanford NC 27330
PH: 919-776-7737
www.CentralCarolinaScale.com
B6E3
Features
· Capacity: 20kg~ 300kg
· High accuracy
· Stainless steel construction
· Low profile and easy installation
Outline Dimension mm(inch)
Wiring:
Shielded, 4 conductor cable: Φ5mm
Standard cable length: 3m
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
· B6E3 load cells are available in the capacities
~
·
·
· Max. ×
20kg 300kg.
17-4PH stainless steel construction, potted
by adhesive inside, oil proof, waterproof,
anti-corrosive gas and medium making it
suitable for all kinds of environments.
Single point with parallel beam, suitable
for electronic scales, platform scales, belt
scales and other electronic weighing devices.
platform size: 400 400mm
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
Capacity
C3
3000
Emax/10000
≤±0.020
≤±0.016
≤±0.011
≤±0.015
2.0 0 2/2.0±0.002
384±4
351±2.0
≥5000(50VDC)
1.5
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
0.02%load value/100mm
± .
20/30/50/75/100/150/200/250/300
IP66
40
(1.57)
Two ends
8-M8-6H Depth 20
6(0.24)
2-3
Two ends
Twoends
19(0.75)
Two ends
150(5.91)
15.5
(0.61)
Φ12.2
Through
33(1.30)
38
(1.50)
38(1.50)
8(0.31)
44
(1.73)
30(1.18)
19
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
nmax
vmin
Underport Depth27
Specifications
20
CANADA
TEL: 416-213-9900
WWW.BRECKNELLSCALES.CA
INDIA
TEL: +91 129 4159774/75/76
WWW.SALTERINDIA.COM
L W
H
W1
H1
8-M
L6F
Features
· Capacity: 50kg~ 2000kg
· High accuracy
· Max. platform size:
50kg~ 200kg 600×600mm
250kg~ 500kg 600×800mm
750kg~ 2000kg 1200×1200mm
· OIML Certificates No:R60/2000-CN1-06.01 Revision 1
· PTB Approval No:D09-06.10
Capacity
Accuracy
Approvals
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
C3
OIML R60 C3
3000
Emax/7000
≤±0.020
≤±0.0167
≤±0.0175
≤±0.020
2.0±0.2
406±6
350±3
≥5000(50VDC)
2
-10~ +40
-35~ +65
5~ 12(DC)
18(DC)
120
150
0.02%load value/100mm
Specifications
· L6F load cells are available in the capacities
50kg~ 2000kg.
· Aluminum construction with parallel beam.
· Silicon adhesive sealed, surface anodized
and anti-corrosion.
· Integral structure and easy installation.
· Suitable for electronic pricing scales, platform
scales and other electronic weighing devices.
Wiring:
hielded, 6 conductor cable, and cable
jacket is PVC.
Cable length: 3±0.1m
Cable diameter: 6.2±0.2mm
S
50/100/150/200/250/500/750/1000/2000
Input (+) Red
Input (-) Yellow
Output (-) White
Output (+) Blue
Shield
Sense (+) Brown
Sense (-) Black
M12-7H Depth20(0.79)
Dimension
Capacity
50~200kg,250kgSE
250~500kg,750kgSE
750~2000kg
H H1 L W W1 M
M16-7H Depth20(0.79)
M12-7H Depth18(0.71)
75(2.95)
95(3.74)
125(4.92)
50(1.97)
70(2.76)
85(3.35)
156(6.14)
146(5.75)
176(6.93)
44(1.73)
60(2.36)
76(2.99)
24(0.94)
36(1.42)
46(1.81)
IP65
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
nmax
vmin
Outline Dimension mm(inch)
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
21
4-R3
2
2 Places
2
4 Places
H2
Twoends
H
H1
Twoends
8-MDepth20
B1
Twoends
3
2Places
L1
B
L
L2
B6F
Features
· Capacity: 100kg~ 2000kg
· High accuracy
· Stainless steel construction
· Low profile and easy installation
· OIML Certificates No:R60/2000-NL1-10.31
Outline Dimension mm(inch)
Wiring:
Shielded, 4 conductor cable: Φ6.2mm
Standard cable length: 3m
· B6F load cells are available in the capacities
100kg~ 2000kg.
· 17-4PH stainless steel construction, potted
by adhesive inside, oil proof, waterproof,
anti-corrosive gas and medium making it
suitable for all kinds of environments.
· Single point with parallel beam, suitable
for electronic scales, platform scales, belt
scales and other electronic weighing devices.
· Max. platform size:
100kg~ 200kg 400×400mm
250kg~ 500kg 600×800mm
750kg~ 2000kg 1200×1200mm
Capacity
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
C3
3000
Emax/10000
≤±0.020
≤±0.016
≤±0.011
≤±0.015
2.0±0.2/2.0±0.002
384±4/400±20
351±2.0
≥5000(50VDC)
1.5
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
0.02%load value/100mm
Specifications
100/150/200/250/500/750/1000/2000
Output (+) Blue
Sense (-) Black
Output (-) White
Input (+) Red
Input (-) Yellow
Sense (+) Brown
Dimension
250kg~500kg
44(1.73)
24(0.94)
75(2.95)
50(1.97)
30(1.18)
156(6.14)
112(4.4)
14(0.55)
M12-7H
B
B1
H
H1
H2
L
L1
L2
M
60(2.36)
36(1.42)
95(3.74)
70(2.76)
30(1.18)
146(5.75)
110(4.33)
11(0.43)
M12-7H
76(2.99)
46(1.81)
125(4.92)
95(3.74)
65(2.56)
176(6.93)
110(4.33)
24(0.94)
M16-7H
750kg~2t100kg~200kg
Capacity
IP66
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
nmax
vmin
9
2
h
t
p
e
D
22
CANADA
TEL: 416-213-9900
WWW.BRECKNELLSCALES.CA
INDIA
TEL: +91 129 4159774/75/76
WWW.SALTERINDIA.COM
H6F
Features
· Capacity: 100kg~ 2000kg
· High accuracy
· Alloy steel construction
· Low profile and easy installation
Outline Dimension mm(inch)
Wiring:
Shielded, 4 conductor cable: Φ5mm
Standard cable length: 3m
· H6F load cells are available in the capacities
100kg~ 2000kg.
· Alloy steel construction, potted
by adhesive inside, oil proof, waterproof,
anti-corrosive gas and medium making it
suitable for all kinds of environments.
· Single point with parallel beam, suitable
for electronic scales, platform scales, belt
scales and other electronic weighing devices.
· Max. platform size:
100kg~ 200kg 400×400mm
250kg~ 500kg 600×800mm
750kg~ 2000kg 1200×1200mm
Capacity
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
C3
3000
Emax/10000
≤±0.020
≤±0.016
≤±0.011
≤±0.015
2.0±0.2/2.0±0.002
384±4/400±20
351±2.0
≥5000(50VDC)
1.5
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
0.02%load value/100mm
Specifications
100/150/200/250/350/500/750/1000/2000
Output (+) Blue
Sense (-) Black
Output (-) White
Input (+) Red
Input (-) Yellow
Sense (+) Brown
Dimension
250kg~500kg
44(1.73)
24(0.94)
75(2.95)
50(1.97)
30(1.18)
156(6.14)
112(4.4)
14(0.55)
M12-7H
B
B1
H
H1
H2
L
L1
L2
M
60(2.36)
36(1.42)
95(3.74)
70(2.76)
30(1.18)
146(5.75)
110(4.33)
11(0.43)
M12-7H
76(2.99)
46(1.81)
125(4.92)
95(3.74)
65(2.56)
176(6.93)
110(4.33)
24(0.94)
M16-7H
750kg~2t100kg~200kg
Capacity
IP66
4-R3
2
2 Places
5
4 Places
H2
Twoends
H
H1
Twoends
8-MDepth20
B1
Twoends
3
2Places
L1
B
L
L2
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
nmax
vmin
9
2
h
t
p
e
D
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
23
Specifications
8-M8-7H Depth 32(1.26)
4 Places
7(0.28)
4 Places
19(0.75)
65(2.56)60(2.36)
30(1.18)
42(1.69)
174(6.86)
43(1.69)
Outline Dimension mm(inch)
L6G
Features
· Capacity: 50kg~ 600kg
· High accuracy
· Max. platform size: 600×600mm
· OIML Certificates No:R60/2000-CN-00.03
· PTB Approval No:D09-03.22 Revision 2
Capacity
Accuracy
Approvals
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
C3
OIML R60 C3
3000
Emax/7000
≤±0.020
≤±0.0167
≤±0.0175
≤±0.020
2.0±0.2
406±6/1065±15
350±3/1000±10
≥5000(50VDC)
2
-10~ +40
-35~ +65
5~ 12(DC)
18(DC)
120
150
0.02%load value/100mm
· L6G load cells are available in the capacities
50kg~ 600kg.
· Aluminum construction with parallel beam.
· Silicon adhesive sealed, surface anodized
and anti-corrosion.
· Integral structure and easy installation.
· Suitable for electronic pricing scales, platform
scales and other electronic weighing devices.
Wiring:
hielded, 6 conductor cable, and cable
jacket is PVC.
Cable length: 3±0.1m
Cable diameter: 6±0.2mm
The shield is connected to the element.
S
50/100/150/200/250/300/500/600
Input (+) Red
Input (-) Black
Output (-) White
Output (+) Green
Shield
Sense (+) Blue
Sense (-) Yellow
IP65
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
nmax
vmin
Underport Depth 40(1.57)
24
CANADA
TEL: 416-213-9900
WWW.BRECKNELLSCALES.CA
INDIA
TEL: +91 129 4159774/75/76
WWW.SALTERINDIA.COM
63(2.48)
65(2.56)
32.5(1.28)
174(6.85)
Twoends
30(1.18)
60(2.36)
16.5
(0.65)
43(1.69)
Two ends
Twoends
8-M8-6H Depth 25(0.98)
Two ends
7(0.28) 19(0.75)
2-3
(0.12)
B6G
Features
· Capacity: 100kg~ 600kg
· High accuracy
· Stainless steel construction
· Low profile and easy installation
Outline Dimension mm(inch)
Wiring:
Shielded, 6 conductor cable: Φ6.2mm
Standard cable length: 3m
· B6G load cells are available in the capacities
100kg~ 600kg.
· 17-4PH stainless steel construction, potted
by adhesive inside, oil proof, waterproof,
anti-corrosive gas and medium making it
suitable for all kinds of environments.
· Single point with parallel beam, suitable
for electronic scales, platform scales, belt
scales and other electronic weighing devices.
· Recommended platform size: 600×600mm
Capacity
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
C3
3000
Emax/10000
≤±0.020
≤±0.016
≤±0.011
≤±0.015
2.0±0.002
384±4
351±2.0
≥5000(50VDC)
1.5
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
0.02%load value/100mm
Specifications
100/150/200/250/300/500/600
Output (+) Blue
Sense (-) Black
Output (-) White
Input (+) Red
Input (-) Yellow
Sense (+) Brown
IP66
kg
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
nmax
vmin
Underport Depth33(1.3)
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
25
H6G
Features
· Capacity: 100kg~ 600kg
· High accuracy
· Alloy steel construction
· Low profile and easy installation
Outline Dimension mm(inch)
Wiring:
Shielded, 6 conductor cable: Φ6.2mm
Standard cable length: 3m
· H6G load cells are available in the capacities
100kg~ 600kg.
· Alloy steel construction, potted
by adhesive inside, oil proof, waterproof,
anti-corrosive gas and medium making it
suitable for all kinds of environments.
· Single point with parallel beam, suitable
for electronic scales, platform scales, belt
scales and other electronic weighing devices.
· Recommended platform size: 600×600mm
Capacity
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
C3
3000
Emax/10000
≤±0.020
≤±0.016
≤±0.011
≤±0.015
2.0±0.002
384±4
351±2.0
≥5000(50VDC)
1.5
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
0.02%load value/100mm
Specifications
100/150/200/250/300/500/600
Output (+) Blue
Sense (-) Black
Output (-) White
Input (+) Red
Input (-) Yellow
Sense (+) Brown
IP66
632.48()
652.56()
32.5(1.28)
174(6.85)
Twoends
30(1.18)
60(2.36)
16.5
(0.65)
43(1.69)
Two ends
Twoends
8-M8-6H Depth 25(0.98)
Two ends
7(0.28) 19(0.75)
2-3
(0.12)
kg
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
nmax
vmin
Underport Depth33(1.3)
26
CANADA
TEL: 416-213-9900
WWW.BRECKNELLSCALES.CA
INDIA
TEL: +91 129 4159774/75/76
WWW.SALTERINDIA.COM
H6G5
Features
· Capacity: 50kg~ 2t
· High accuracy
· Alloy steel construction
· Low profile and easy installation
Outline Dimension mm(inch)
Wiring:
Shielded, 4 conductor cable: Φ6.2mm
Standard cable length: 3m
· H6G5 load cells are available in the capacities
50kg~ 2000kg.
· Alloy steel construction, potted
by adhesive inside, oil proof, waterproof,
anti-corrosive gas and medium making it
suitable for all kinds of environments.
· Single point with parallel beam, suitable
for electronic scales, platform scales, belt
scales and other electronic weighing devices.
· Max. platform size:
50kg~ 1t 600×800mm
1.5t~ 2t 1000×1000mm
tCapacity
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
C3
3000
Emax/10000
≤±0.020
≤±0.016
≤±0.011
≤±0.015
2.0±0.002
384±4
351±2.0
≥5000(50VDC)
1.5
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
120
150
0.02%load value/100mm
Specifications
Output (+) Blue
Sense (-) Black
Output (-) White
Input (+) Red
Input (-) Yellow
Sense (+) Brown
Dimension 1.5t~2t50kg~1t
Capacity
50kg/100kg/150kg/200kg/250kg/300kg/500kg/1t/2t
L
H
H1
W
W1
68(2.68)
38(1.50)
77(3.03)
46(1.81)
76(2.99)
150(5.91)150(5.91)
88(3.46)
55(2.17)
42(1.65)
IP66
16.5(0.65)
8-M14-6H Depth 25
2-3
H
H1
Twoends
H/2
2-W1
Twoends
W
L
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
nmax
vmin
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
27
Outline Dimension mm(inch)
L6H5
Features
· Capacity: 4kg~ 20kg
· High accuracy
· Max. platform size: 200×200mm
· OIML Certificates No:R60/2000-NL1-10.23
Capacity
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
kg
Specifications
4/5/6/8/10/20
C3D
2500
Emax/5000
≤±0.030
≤±0.020
≤±0.020
≤±0.020
2.0±0.2
406±6
350±3
≥5000(50VDC)
2
-10~ +40
-35~ +65
5~ 12(DC)
18(DC)
120
150
0.02%load value/100mm
· L6H5 load cells are available in the capacities
4kg~ 20kg.
· Aluminum construction with parallel beam.
· Silicon adhesive sealed, surface anodized
and anti-corrosion.
· Integral structure and easy installation.
· Suitable for electronic balance and other
electronic weighing devices.
Wiring:
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
Shielded, 4 conductor cable, and cable
jacket is PVC.
Cable length: 0.17±0.05m
Cable diameter: 3.8±0.2mm
2Places
28(1.18)
50(1.97)
20(0.79)
80(3.15)
4-M8Depth10(0.39)
2Places
IP65
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
nmax
vmin
28
CANADA
TEL: 416-213-9900
WWW.BRECKNELLSCALES.CA
INDIA
TEL: +91 129 4159774/75/76
WWW.SALTERINDIA.COM
Outline Dimension mm(inch)
L6J
Features
· Capacity: 1kg~ 20kg
· High accuracy
· Max. platform size: 200×200mm
Capacity
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
kg
Specifications
· L6J load cells are available in the capacities
1kg~ 20kg.
· Aluminum construction with parallel beam.
· Silicon adhesive sealed, surface anodized
and anti-corrosion.
· Integral structure and easy installation.
· Suitable for electronic balance and other
electronic weighing devices.
Wiring:
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
Shielded, 4 conductor cable, and cable
jacket is PVC.
Cable length: 0.45±0.05m
Cable diameter: 3.0±0.2mm
32(1.26)
2 Places
32(1.26)
10(0.39)
2 Places
2-M5Depth18(0.71)
79(3.11)
88(3.46)
16(0.63)
2-M5 Depth 18(0.71)
IP65
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
nmax
vmin
1/2/3/5/8/10/15/20
C3D
2500
Emax/5000
≤±0.030
≤±0.020
≤±0.020
≤±0.020
1.5±0.2
406±6
350±3
≥5000(50VDC)
2
-10~ +40
-35~ +65
5~ 12(DC)
18(DC)
120
150
0.02%load value/100mm
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
29
4-M3 Depth 14(0.55)
70(2.76)
2Places
7(0.28)
12
(0.47)
22
(0.87)
2 Through holes
6
(0.23)
Outline Dimension mm(inch)
L6J1
Features
· Capacity: 0.3kg~3kg
· High accuracy
· Max. platform size: 200×200mm
Capacity
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
kg
Specifications
· L6J1 load cells are available in the capacities
0.3kg~3kg.
· Aluminum construction with parallel beam.
· Silicon adhesive sealed, surface anodized
and anti-corrosion.
· Integral structure and easy installation.
· Suitable for electronic balance and other
electronic weighing devices.
Wiring:
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
Shielded, 4 conductor cable, and cable
jacket is PVC.
Cable length: 0.45±0.05m
Cable diameter: 3.0±0.2mm
IP65
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
nmax
vmin
0.3/0.4/0.5/0.6/1/3
C3D
2500
Emax/5000
≤±0.030
≤±0.020
≤±0.030
≤±0.030
1.0±0.1
394±6
350±3
≥5000(50VDC)
2
-10~+40
-35~+65
5~ 12(DC)
18(DC)
120
150
0.02%load value/100mm
30
CANADA
TEL: 416-213-9900
WWW.BRECKNELLSCALES.CA
INDIA
TEL: +91 129 4159774/75/76
WWW.SALTERINDIA.COM
Outline Dimension mm(inch)
L6L
Features
· Capacity: 5kg~ 200kg
· High accuracy
· Max. platform size: 350×400mm
Capacity
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
kg
· L6L load cells are available in the capacities
5kg~ 200kg.
· Aluminum construction with parallel beam.
· Silicon adhesive sealed, surface anodized
and anti-corrosion.
· Integral structure and easy installation.
· Suitable for electronic balance and other
electronic weighing devices.
Wiring:
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
Shielded, 4 conductor cable,
and cable jacket is PVC.
Cable length: 1.0±0.05m
Cable diameter: 5.3±0.2mm
IP65
40(1.57)
F View
2-M6 Depth 20(0.79)M6-7H Through hole
18(0.71)
6(0.24) 18(0.71) 31(1.22)
2Places
4-M6 Depth 20(0.79)
6(0.24)
F View
18(0.71)
18(0.71)
150(5.91)
Specifications
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
nmax
vmin
5/8/10/15/20/30/50/80/100/150/200
C3D
2500
Emax/5000
≤±0.030
≤±0.020
≤±0.021
≤±0.028
2.0±0.2
394±6
350±3
≥5000(50VDC)
2
-10~ +40
-35~ +65
5~ 12(DC)
18(DC)
120
150
0.02%load value/100mm
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
31
Capacity
Accuracy
Approvals
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
kg
Specifications
3/5/8/10/15/20/30/50/75/100
C3
OIML R60 C3
3000
Emax/7000
≤±0.020
≤±0.0167
≤±0.0175
≤±0.020
2.0±0.2
406±6
350±3
≥5000(50VDC)
2
-10~ +40
-35~ +65
5~ 12(DC)
18(DC)
120
150
0.02%load value/100mm
Outline Dimension mm(inch)
L6N
Features
· Capacity: 3kg~ 100kg
· High accuracy
· Max. Platform size: 400×400mm
· OIML Certificates No:R60/2000-CN1-06.04
· PTB Approval No:D09-06.11
· NTEP Certificates No: CC11-055
· L6N load cells are available in the capacities
3kg~ 100kg.
· Aluminum construction with parallel beam.
· Silicon adhesive sealed, surface anodized
and anti-corrosion.
· Integral structure and easy installation.
· Suitable for electronic balance and other
electronic weighing devices.
Wiring:
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
Shielded, 4 conductor cable, and cable
jacket is PVC.
Cable length: 3.0±0.05m
Cable diameter: 5.0±0.2mm
Ip65
7-M Depth 15(0.59)
19(0.75)
2Places
31.24
(1.23)
11.18
(0.44)
40
(1.58)
19
(0.75)
150(5.9)
5.84(0.23)
2Places
25.4
(1.0)
100(3.94)
34
(1.34)
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
nmax
vmin
32
CANADA
TEL: 416-213-9900
WWW.BRECKNELLSCALES.CA
INDIA
TEL: +91 129 4159774/75/76
WWW.SALTERINDIA.COM
B6N
Features
· Capacity: 15kg~ 200kg
· High accuracy
· Stainless steel construction
· Low profile and easy installation
· OIML Certificates No:R60/2000-NL1-11.27
Outline Dimension mm(inch)
Wiring:
hielded, 4 conductor cable: Φ5mm
Standard cable length: 1m
S
· B6N load cells are available in the capacities
15kg~ 200kg.
· 17-4PH stainless steel construction, potted
by adhesive inside, oil proof, waterproof,
anti-corrosive gas and medium making it
suitable for all kinds of environments.
· Single point with parallel beam, suitable
for electronic scales, platform scales, belt
scales and other electronic weighing devices.
· Recommended platform size: 400×400mm
Capacity
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
C3
3000
Emax/10000
≤±0.020
≤±0.016
≤±0.011
≤±0.015
2.0±0.002
384±4
351±2.0
≥5000(50VDC)
1.5
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
0.02%load value/100mm
Specifications
Output (+) White
Sense (-) Yellow
Output (-) Red
Input (+) Green
Input (-) Black
Sense (+) Blue
15/20/30/50/75/100/150/200
Note:
Machining thread hole M and N are basing
on customers' requirements.
When customers require imperial:
Thread hole M is 1/4-20UNC-2B,
Thread hole N is 1/4-28UNF-2B;
When customers require metric:
Both thread holes M and N are M6-6H,
and there will be an "M" under exit hole.
·
·
·
IP66
34
Twoends(1.34)
19.05
(0.75)
25
(0.98)
38(1.5)
19.05(0.75)
150(5.91)
H1
4-MDepth15(0.59)
H
40(1.57)
38(1.496)
NDepth15(0.59)
100(3.94)
kg
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
nmax
vmin
Underport Depth18(0.71)
Underport Depth18(0.71)
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
33
Outline Dimension mm(inch)
L6Q
Features
· Capacity: 50kg~ 250kg
· High accuracy
· Max. platform size: 400×400mm
PTB Approval No: D09-07.06·
· NTEP Certificates No: CC11-104
Capacity
Accuracy
Approvals
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
C3
OIML R60 C3
3000
Emax/7000
≤±0.020
≤±0.0167
≤±0.0175
≤±0.020
2.0±0.2
406±6
350±3
≥5000(50VDC)
2
10~ +40
-35~ +65
5~ 12(DC)
18(DC)
120
150
0.02%load value/100mm
-
kg
Specifications
· L6Q load cells are available in the capacities
50kg~ 250kg.
· Aluminum construction with parallel beam.
· Silicon adhesive sealed, stainless steel cover, surface
anodized and anti-corrosion.
· Integral structure and easy installation.
· Suitable for electronic pricing scales, platform
scales and other electronic weighing devices.
Wiring:
Shielded, 6 conductor cable, and cable
jacket is PVC.
Cable length: 3.0±0.05m
Cable diameter: 5.0±0.2mm
50/100/150/200/250
Input (+) Red
Input (-) Black
Output (-) White
Output (+) Green
Sense (+) Blue
Sense (-) Brown
M
Metric Imperial
M6 1/4-20UNC
8-M Depth 13(0.51)
6.35(0.25)
2 Places
25.1(1.0)
2 Places
150(5.91)
25.4(1.0)
44(1.73)
38.1(1.5)
2Places
38.1(1.5)
IP66
nmax
vmin
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
Depth15(0.59)
34
CANADA
TEL: 416-213-9900
WWW.BRECKNELLSCALES.CA
INDIA
TEL: +91 129 4159774/75/76
WWW.SALTERINDIA.COM
B6Q
Features
· Capacity: 200kg and 250kg.
· High accuracy
· Stainless steel construction
· Low profile and easy installation
Outline Dimension mm(inch)
Wiring:
Shielded, 6 conductor cable: Φ5.0mm
Standard cable length: 1.5m
· B6Q load cells are available in the capacities
200kg and 250kg.
· 17-4PH stainless steel construction, potted
by adhesive inside, oil proof, waterproof,
anti-corrosive gas and medium making it
suitable for all kinds of environments.
· Single point with parallel beam, suitable
for electronic scales, platform scales, belt
scales and other electronic weighing devices.
· Recommended platform size:400×400mm
kgCapacity
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
C3
3000
Emax/10000
≤±0.020
≤±0.016
≤±0.011
≤±0.015
2.0±0.2/2.0±0.002
384±4/400±20
351±2.0
≥5000(50VDC)
1.5
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
0.02%load value/100mm
Specifications
Output (+) White
Sense (-) Yellow
Output (-) Red
Input (+) Green
Input (-) Black
Sense (+) Blue
200/250
IP66
38.1
Twoends(1.5)
38
(1.5)
9.35
(0.37)
38
(1.5)
39.9
(1.57)
8-1/4-20UNF-2BDepth15(0.59)
38.1(1.5)
6.35
(0.25)
25.4
4Places(1.0)
150(5.91)
8(0.31)
4-25.4(1.0)
Twoends
1/4-28UNF-2B Depth10
41.5(1.63)
nmax
vmin
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
Underport Depth12
Underport Depth18(0.71)
35
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
35
L6T
Features
· Capacity: 50kg~ 1000kg
· High accuracy
· Max. platform size: 600×600mm
· OIML Certificates No:R60/2000-DE1-10.11
Capacity
Accuracy
Approvals
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
C3
OIML R60 C3
3000
Emax/7000
≤±0.020
≤±0.0167
≤±0.0175
≤±0.020
2.0±0.2
406±6
350±3
≥5000(50VDC)
2
-10~ +40
-35~ +65
5~ 12(DC)
18(DC)
120
150
0.02%load value/100mm
kg
Specifications
· L6T load cells are available in the capacities
50kg~ 1000kg.
· Aluminum construction with parallel beam.
· Silicon adhesive sealed, surface anodized
and anti-corrosion.
· Integral structure and easy installation.
· Suitable for electronic pricing scales, electronic
platform scales and other electronic weighing devices.
Wiring:
Shielded, 6 conductor cable, and cable
jacket is PVC.
Cable length: 3.0±0.1m
Cable diameter: 5.0±0.2mm
50/75/100/150/200/250/300/500/635/1000
Input (+) Red
Input (-) Black
Output (-) White
Output (+) Green
Sense (+) Blue
Sense (-) Brown
M
Metric Imperial
M8x1.25 5/16-18UNC-2B
76.2(3.0)
39.8
(1.57)
2Places
24.9(0.98)8-D Depth16(0.63)
60.2(2.37)
2Places
2Places
39.8
(1.57)
7.87(0.31)
2Places
191(7.52)
75.44(2.97)
IP65
nmax
vmin
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
Outline Dimension mm(inch)
36
CANADA
TEL: 416-213-9900
WWW.BRECKNELLSCALES.CA
INDIA
TEL: +91 129 4159774/75/76
WWW.SALTERINDIA.COM
Outline Dimension mm(inch)
L6W
Features
· Capacity: 50kg~ 635kg
· High accuracy
· Recommended platform size:
50kg~ 200kg: 600×600mm
250kg~ 635kg:600×800mm
· OIML Certificates No:R60/2000-CNI-06.03
· PTB Approval No: D09-06.12
Capacity
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
C3
3000
Emax/7000
≤±0.020
≤±0.0167
≤±0.0175
≤±0.020
2.0±0.2
406±6
350±3
≥5000(50VDC)
2
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
0.02%load value/100mm
Specifications
· L6W load cells are available in the capacities
50kg~ 635kg.
· Aluminum construction with parallel beam.
· Silicon adhesive sealed, surface anodized
and anti-corrosion.
· Integral structure and easy installation.
· Suitable for electronic balance and other
electronic weighing devices.
Wiring:
Shielded, 4 conductor cable, and cable
jacket is PVC.
Cable length: 3.0±0.1m
Cable diameter: 4.7±0.2mm
50/100/150/200/250/300/500/635
Input (+) Red
Input (-) Black
Output (-) White
Output (+) Green
Sense (+) Blue
Sense (-) Brown
2Places
55(2.17)2Places
2Places
188(7.40)
5.5(0.22) 35(1.38)
2Places
50(1.97)
2Places
8-M8(0.31)-6M Depth 20(0.79)
63.5(2.51)
IP65
62.3(2.45)
kg
Approvals OIML R60 C3
nmax
vmin
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
37
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
37
BM6A
Features
· Capacity: 6kg~ 60kg
· High accuracy
· Stainless steel construction
· Low profile and easy installation
· OIML Certificate No: R60/2000-NL1-10.32
Outline Dimension mm(inch)
Wiring:
Cable diameter: Φ5±0.2mm
Standard length for 6 conductor cable: 6m
· BM6A load cells are available in the capacities
6kg~ 60kg, and 25~ 100lb.
· 17-4PH stainless steel construction, potted
by adhesive inside, oil proof, waterproof,
anti-corrosive gas and medium making it
suitable for all kinds of environments.
· Single point with parallel beam, suitable
for electronic scales, platform scales, belt
scales, packaging scales and other electronic
weighing devices.
· Recommended platform size: 300×300mm
Dimension
Capacity
6,12,15,30kg
60kg
L H W
130(5.12)
130(5.12)
50(1.96)
50(1.96)
18.5(0.73)
23.5(0.92)
6,12,15,30,60kg
50
(1.97)
10-M6 Depth 8(0.32)
W
25
(0.98)
42.5(1.67) 19(0.75)
L
(0.95)
24
19
(0.75)
65(2.56)
157(6.18)
6
(0.24)24
(0.95)
Output (+) White
Sense (-) Blue
Output (-) Red
Input (+) Green
Input (-) Black
Sense (+) Yellow
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
kgCapacity
C3
3000
Emax/10000
≤±0.020
≤±0.016
≤±0.011
≤±0.015
2.0±0.2/2.0±0.002/3.0±0.2
400±20
351±2.0
≥5000(50VDC)
1.5
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
Specifications
Note: output sensitivity of S1 type is 2.0±0.002mv/v; output of imperial model is 3.0±0.2mv/v,
0.02% /100mmload value
6/12/30/60
nmax
vmin
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
38
CANADA
TEL: 416-213-9900
WWW.BRECKNELLSCALES.CA
INDIA
TEL: +91 129 4159774/75/76
WWW.SALTERINDIA.COM
BM6E
Features
· Capacity: 3kg~ 300kg
· High accuracy
· Stainless steel construction
· Low profile and easy installation
Outline Dimension mm(inch)
Wiring:
Shielded, 4 conductor cable: Φ5mm
Standard cable length: 2m
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
· BM6E load cells are available in the capacities
50kg~ 300kg.
· Stainless steel construction, hermetically welded
oil proof, waterproof,
anti-corrosive gas and medium making it
suitable for all kinds of environments.
· Single point with parallel beam, suitable
for electronic scales, platform scales, belt
scales and other electronic weighing devices.
· Recommended platform size: 600×600mm
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
Capacity
C3
3000
Emax/10000
≤±0.020
≤±0.016
≤±0.011
≤±0.015
2.0±0.2/2.0±0.002
350±3.5
351±2.0
≥5000(50VDC)
1.5
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
Specifications
3/50/100/200/300
0.02% /100mmload value
150(5.9)
15
(0.59)
40(1.57)
35(1.38)
8-M6-6H Depth 15(0.59)7(0.28)
2 Places
15(0.59)
2Places
19(0.75)
2 Places
kg
nmax
vmin
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
Depth 17(0.67)
37
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
39
BM6G
Features
· Capacity: 75kg~ 500kg
· High accuracy
· Stainless steel construction
· Low profile and easy installation
· PTB Approval NO:D09-10.06
· OIML Certificates NO:R60/2000-NL1-11.29
· NTEP Certificate No: CC12-017
· BM6G load cells are available in the capacities
75kg~ 500kg.
· 17-4PH stainless steel construction, potted
by adhesive inside, oil proof, waterproof,
anti-corrosive gas and medium making it
suitable for all kinds of environments.
· Single point with parallel beam, suitable
for electronic scales, platform scales, belt
scales and other electronic weighing devices.
· Safe and anti-explosive product, can be used in
atrocious environment and hazardous areas.
· Recommended platform size: 800×800mm
Outline Dimension mm(inch)
Wiring:
Shielded, 4 conductor cable:Φ5mm
Standard cable length: 3m
Output (+) Green
Input (-) Black
Output (-) White
Input (+) Red
43(1.69)
2 Places
62
(2.44)
19(0.75)
2 Places7
(0.28)
18
(0.71)
174(6.85)
45(1.77)
30(1.81)
2Places
8-M8 Depth18(0.71)
62(2.44)
64(2.52)
32(1.26)
Capacity
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
Corner correction
C3
3000
Emax/10000
≤±0.020
≤±0.016
≤±0.011
≤±0.015
2.0±0.2/2.0±0.002
350±3.5
350±3.5
≥5000(50VDC)
1.5
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
0.02%load value/100mm
Specifications
3/75/100/150/200/300/400/500kg
nmax
vmin
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
OIML R60 C3Approvals
Depth 22(0.87)
40
CANADA
TEL: 416-213-9900
WWW.BRECKNELLSCALES.CA
INDIA
TEL: +91 129 4159774/75/76
WWW.SALTERINDIA.COM
Features
· Capacity: 500kg~ 50t
· High accuracy
· Alloy steel construction
· Low profile
· OIML Certificate No: R60/2000-NL1-12.14
Accessories
· HY-8-101
· HM-8-401
· HM-8-406
· Hm8 load cells are available in the capacities 500kg~ 50t.
· Alloy steel, hermetically welded, oil-proof,
waterproof and anti-corrosion, suitable for
all kinds of environments.
· Single shear beam, easy for installation, suitable for
electronic truck scales, track scales, hopper scale and
other electronic weighing devices.
· Safe and anti-explosive product, can be used in
atrocious environment and hazardous areas.
HM8
Outline Dimension mm(inch)
37
(1.47)
57.9
(2.28)
37
(1.47)
57.9
(2.28)
37
(1.47)
62.9
(2.48)
Capacity
Dimension
35
(1.38)
48
(1.89)
78.7
(3.1)
60
(2.36)
127.7
(5.03)
35
(1.38)
35
(1.38)
42
(1.65)
57
(2.24)
1-2t
2.5t
3t
5t
5
(0.2)
5
(0.2)
5
(0.2)
8
(0.31)
12
(0.47)
43
(1.69)
43
(1.69)
43
(1.69)
52
(2.05)
67
(2.64)
37
(1.47)
37
(1.47)
15
(0.59)
48
(1.89)
60
(2.36)
37
(1.47)
13
(0.51)
15
(0.59)
21
(0.83)
28
(1.10)
203
(7.99)
203
(7.99)
203
(7.997)
235
(9.25)
279
(10.98)
95
(3.74)
95
(3.74)
95
(3.74)
110
(4.33)
133
(5.24)
22
(0.87)
22
(0.87)
22
(0.87)
22
(0.87)
32
(1.26)
98
(3.86)
98
(3.86)
98
(3.86)
124
(4.88)
140
(5.51)
82.5
(3.25)
115
(4.53)
90
(3.54)
70
(2.76)
12
(0.47)
18
(0.71)
143.5
(5.65)
174
(6.85)
70
(2.76)
70
(2.76)
34
(1.34)
26
(1.02)
70
(2.76)
96
(3.78)
318
(12.52)
374
(14.72)
153
(6.02)
189
(7.44)
38
(1.5)
44.5
(1..75)
159
(6.26)
181
(7.13)
64
(2.52)
64
(2.52)
64
(2.52)
66
(2.6)
82
(3.32)
89
(3.5)
76
(2.99)
/
/
/
/
/
/
51
(2.01)
/
/
/
/
/
/
46
(1.81)
Wiring:
Shielded, 6 conductor cable:Φ6.2mm
Standard cable length: 6m
Output (+) Blue
Sense (-) Black
Output (-) White
Input (+) Red
Input (-) Yellow
Sense (+) Brown
10t,15t
20t,25t
30t
H H1 H2 H3 ΦD ΦdW L L1 L2 L3 L4 L5 L6
L
H2
H1
L1
H3
2-Φd
30t,50tThrough hole
Through hole 0.5t,25t
L4 L3 L2
L6
WW
H
L5 L3 L2L4
ΦD
6-Φd
tCapacity
Accuracy
Maximum number of verification intervals
Minimum load cell verification interval
Combined error
Creep
Temperature effect on sensitivity
Temperature effect on zero
Output sensitivity
Input resistance
Output resistance
Insulation resistance
Zero balance
Temperature, compensated
Temperature, operating
Excitation, recommended
Excitation, max
Safe overload
Ultimate overload
C3
3000
Emax/10000
≤±0.020
≤±0.016
≤±0.011
≤±0.015
Specifications
500kg/1/2/2.5/3/5/10/15/20/25/30/50
2.0±0.002
350±3.5
352±3.0
≥5000(50VDC)
1.5
-10~ +40
-35~ +70
5~ 12(DC)
18(DC)
150
300
nmax
vmin
(%FS)
(%FS/30min)
(%FS/10℃)
(%FS/10℃)
(mv/v)
(Ω)
(Ω)
(MΩ)
(%FS)
(℃)
(℃)
(V)
(V)
(%FS)
(%FS)
37
UNITED STATES
TEL: 800-637-0529
WWW.BRECKNELLSCALES.COM
UNITED KINGDOM
TEL: + 44 (0) 845 246 6717
WWW.BRECKNELLSCALES.CO.UK
41
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales
Brecknell Replacement Load Cells For Scales

Contenu connexe

En vedette

компьютерные сети
компьютерные сетикомпьютерные сети
компьютерные сети
student_SSGA
 
Top 8 it support engineer resume samples
Top 8 it support engineer resume samplesTop 8 it support engineer resume samples
Top 8 it support engineer resume samples
jomcoret
 
Cenit 2 Grupo Frial
Cenit 2 Grupo FrialCenit 2 Grupo Frial
Cenit 2 Grupo Frial
Grupo Frial
 
Redes Sociais - Sou mais Web - julho/2009
Redes Sociais - Sou mais Web - julho/2009Redes Sociais - Sou mais Web - julho/2009
Redes Sociais - Sou mais Web - julho/2009
Camila Leite
 

En vedette (17)

Planifccion
PlanifccionPlanifccion
Planifccion
 
¿Qué es el RSS?
¿Qué es el RSS?¿Qué es el RSS?
¿Qué es el RSS?
 
Web 2 Health 2 Presentation
Web 2 Health 2 PresentationWeb 2 Health 2 Presentation
Web 2 Health 2 Presentation
 
Brochure drylin E igus®
Brochure drylin E igus®Brochure drylin E igus®
Brochure drylin E igus®
 
Zhang Wenyu, Work Samples
Zhang Wenyu, Work SamplesZhang Wenyu, Work Samples
Zhang Wenyu, Work Samples
 
TechShanghai2016 - 高可靠性PCB – 从设计到制造
TechShanghai2016 - 高可靠性PCB – 从设计到制造TechShanghai2016 - 高可靠性PCB – 从设计到制造
TechShanghai2016 - 高可靠性PCB – 从设计到制造
 
компьютерные сети
компьютерные сетикомпьютерные сети
компьютерные сети
 
iPad apps for creative learning
iPad apps for creative learningiPad apps for creative learning
iPad apps for creative learning
 
Porque elegir francia 2011
Porque elegir francia 2011Porque elegir francia 2011
Porque elegir francia 2011
 
Yearbook2014
Yearbook2014Yearbook2014
Yearbook2014
 
4maila 2009 05_mintzamena-1
4maila 2009 05_mintzamena-14maila 2009 05_mintzamena-1
4maila 2009 05_mintzamena-1
 
Top 8 it support engineer resume samples
Top 8 it support engineer resume samplesTop 8 it support engineer resume samples
Top 8 it support engineer resume samples
 
Cenit 2 Grupo Frial
Cenit 2 Grupo FrialCenit 2 Grupo Frial
Cenit 2 Grupo Frial
 
Redes Sociais - Sou mais Web - julho/2009
Redes Sociais - Sou mais Web - julho/2009Redes Sociais - Sou mais Web - julho/2009
Redes Sociais - Sou mais Web - julho/2009
 
Вестник Союза франчайзинга
Вестник Союза франчайзингаВестник Союза франчайзинга
Вестник Союза франчайзинга
 
Consumer Electronics_B Plan Final
Consumer Electronics_B Plan FinalConsumer Electronics_B Plan Final
Consumer Electronics_B Plan Final
 
Quien es MultiON
Quien es MultiONQuien es MultiON
Quien es MultiON
 

Plus de ccscale

Ohaus Industrial Scales Brochure 2015
Ohaus Industrial Scales Brochure 2015Ohaus Industrial Scales Brochure 2015
Ohaus Industrial Scales Brochure 2015
ccscale
 

Plus de ccscale (11)

Detecto FoodService Scale Catalog
Detecto FoodService Scale CatalogDetecto FoodService Scale Catalog
Detecto FoodService Scale Catalog
 
Safety of Life at Sea (Solas) Weighing Scale Guide
Safety of Life at Sea (Solas) Weighing Scale GuideSafety of Life at Sea (Solas) Weighing Scale Guide
Safety of Life at Sea (Solas) Weighing Scale Guide
 
Safety of Life at Sea (SOLAS) Shippers Guide
Safety of Life at Sea (SOLAS) Shippers Guide Safety of Life at Sea (SOLAS) Shippers Guide
Safety of Life at Sea (SOLAS) Shippers Guide
 
Brecknell Load Cell Catalog 2015
Brecknell Load Cell Catalog 2015Brecknell Load Cell Catalog 2015
Brecknell Load Cell Catalog 2015
 
Avery Weigh-Tronix Warehouse Scales Brochure
Avery Weigh-Tronix Warehouse Scales BrochureAvery Weigh-Tronix Warehouse Scales Brochure
Avery Weigh-Tronix Warehouse Scales Brochure
 
Ohaus Laboratory Balance Brochure 2015
Ohaus Laboratory Balance Brochure 2015Ohaus Laboratory Balance Brochure 2015
Ohaus Laboratory Balance Brochure 2015
 
Ohaus Industrial Scales Brochure 2015
Ohaus Industrial Scales Brochure 2015Ohaus Industrial Scales Brochure 2015
Ohaus Industrial Scales Brochure 2015
 
Sensortronics Load Cell Catalog 2015
Sensortronics Load Cell Catalog 2015Sensortronics Load Cell Catalog 2015
Sensortronics Load Cell Catalog 2015
 
CAS Scale Load Cells and Weigh Modules
CAS Scale Load Cells and Weigh ModulesCAS Scale Load Cells and Weigh Modules
CAS Scale Load Cells and Weigh Modules
 
Veterinary Scales For Weighing Dogs
Veterinary Scales For Weighing DogsVeterinary Scales For Weighing Dogs
Veterinary Scales For Weighing Dogs
 
Rice Lake Survivor OTR Truck Scale
Rice Lake Survivor OTR Truck ScaleRice Lake Survivor OTR Truck Scale
Rice Lake Survivor OTR Truck Scale
 

Dernier

call Now 9811711561 Cash Payment乂 Call Girls in Dwarka Mor
call Now 9811711561 Cash Payment乂 Call Girls in Dwarka Morcall Now 9811711561 Cash Payment乂 Call Girls in Dwarka Mor
call Now 9811711561 Cash Payment乂 Call Girls in Dwarka Mor
vikas rana
 

Dernier (15)

(Anamika) VIP Call Girls Navi Mumbai Call Now 8250077686 Navi Mumbai Escorts ...
(Anamika) VIP Call Girls Navi Mumbai Call Now 8250077686 Navi Mumbai Escorts ...(Anamika) VIP Call Girls Navi Mumbai Call Now 8250077686 Navi Mumbai Escorts ...
(Anamika) VIP Call Girls Navi Mumbai Call Now 8250077686 Navi Mumbai Escorts ...
 
(Aarini) Russian Call Girls Surat Call Now 8250077686 Surat Escorts 24x7
(Aarini) Russian Call Girls Surat Call Now 8250077686 Surat Escorts 24x7(Aarini) Russian Call Girls Surat Call Now 8250077686 Surat Escorts 24x7
(Aarini) Russian Call Girls Surat Call Now 8250077686 Surat Escorts 24x7
 
2k Shots ≽ 9205541914 ≼ Call Girls In Dashrath Puri (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Dashrath Puri (Delhi)2k Shots ≽ 9205541914 ≼ Call Girls In Dashrath Puri (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Dashrath Puri (Delhi)
 
The Selfspace Journal Preview by Mindbrush
The Selfspace Journal Preview by MindbrushThe Selfspace Journal Preview by Mindbrush
The Selfspace Journal Preview by Mindbrush
 
LC_YouSaidYes_NewBelieverBookletDone.pdf
LC_YouSaidYes_NewBelieverBookletDone.pdfLC_YouSaidYes_NewBelieverBookletDone.pdf
LC_YouSaidYes_NewBelieverBookletDone.pdf
 
WOMEN EMPOWERMENT women empowerment.pptx
WOMEN EMPOWERMENT women empowerment.pptxWOMEN EMPOWERMENT women empowerment.pptx
WOMEN EMPOWERMENT women empowerment.pptx
 
8377087607 Full Enjoy @24/7-CLEAN-Call Girls In Chhatarpur,
8377087607 Full Enjoy @24/7-CLEAN-Call Girls In Chhatarpur,8377087607 Full Enjoy @24/7-CLEAN-Call Girls In Chhatarpur,
8377087607 Full Enjoy @24/7-CLEAN-Call Girls In Chhatarpur,
 
2k Shots ≽ 9205541914 ≼ Call Girls In Mukherjee Nagar (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Mukherjee Nagar (Delhi)2k Shots ≽ 9205541914 ≼ Call Girls In Mukherjee Nagar (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Mukherjee Nagar (Delhi)
 
Top Rated Pune Call Girls Tingre Nagar ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Tingre Nagar ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Tingre Nagar ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Tingre Nagar ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
2k Shots ≽ 9205541914 ≼ Call Girls In Jasola (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Jasola (Delhi)2k Shots ≽ 9205541914 ≼ Call Girls In Jasola (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Jasola (Delhi)
 
2k Shots ≽ 9205541914 ≼ Call Girls In Palam (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Palam (Delhi)2k Shots ≽ 9205541914 ≼ Call Girls In Palam (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Palam (Delhi)
 
$ Love Spells^ 💎 (310) 882-6330 in West Virginia, WV | Psychic Reading Best B...
$ Love Spells^ 💎 (310) 882-6330 in West Virginia, WV | Psychic Reading Best B...$ Love Spells^ 💎 (310) 882-6330 in West Virginia, WV | Psychic Reading Best B...
$ Love Spells^ 💎 (310) 882-6330 in West Virginia, WV | Psychic Reading Best B...
 
9892124323, Call Girls in mumbai, Vashi Call Girls , Kurla Call girls
9892124323, Call Girls in mumbai, Vashi Call Girls , Kurla Call girls9892124323, Call Girls in mumbai, Vashi Call Girls , Kurla Call girls
9892124323, Call Girls in mumbai, Vashi Call Girls , Kurla Call girls
 
Pokemon Go... Unraveling the Conspiracy Theory
Pokemon Go... Unraveling the Conspiracy TheoryPokemon Go... Unraveling the Conspiracy Theory
Pokemon Go... Unraveling the Conspiracy Theory
 
call Now 9811711561 Cash Payment乂 Call Girls in Dwarka Mor
call Now 9811711561 Cash Payment乂 Call Girls in Dwarka Morcall Now 9811711561 Cash Payment乂 Call Girls in Dwarka Mor
call Now 9811711561 Cash Payment乂 Call Girls in Dwarka Mor
 

Brecknell Replacement Load Cells For Scales

  • 1. Brecknell 1000 Armstrong Drive Fairmont, Minnesota 56031 Toll Free: 800-637-0529 Telephone: 507-238-8702 Fax: 507-238-8271 Email: sales@brecknellscales.com Brecknell Foundry Lane Smethwick, West Midlands England B66 2LP Telephone: +44 (0) 845 246 6717 Fax: +44 (0) 845 246 6718 Email: sales@brecknellscales.co.uk Www.brecknellscales.co.uk Brecknell 217 Brunsweick Boulevard Pointe-claire, Quebec Canada H9R 4R7 Toll Free: 800-268-1662 Telephone: 416-213-9900 Fax: 416-213-9960 Email: sales@brecknellscales.ca Salter India Limited Plot #53, Sector 25, (Avery India Compound) Ballabgarh 121 004, Faridabad, Harvana (India) Telephone: 91-129-4094400 Fax: 91-129-4094591, 2234091 Email: Sales@averyindia.net Www.salterindia.com Manufacturer Models Excitation + Excitation - Signal + Signal - Shield Sense + Sense - A&D Engineering RED WHITE GREEN BLUE YELLOW Allegany Technology GREEN BLACK RED WHITE BARE Advance Transducers RED BLACK GREEN WHITE BARE Allegany GREEN BLACK WHITE RED BARE Alphartron RED BLACK GREEN WHITE BARE Anyload RED BLACK GREEN WHITE BARE 108LSMT GREEN BLACK RED WHITE BARE BLUE BROWN Artech RED BLACK GREEN WHITE BARE Avery Weigh-Tronix GREEN BLACK WHITE RED WHITE/ORANGE Beowulf GREEN BLACK WHITE RED BARE BLH GREEN BLACK WHITE RED YELLOW Cas RED BLACK GREEN WHITE BARE BLUE BROWN Celtron RED BLACK GREEN WHITE BARE Cardinal GREEN BLACK WHITE RED BARE CNCell RED BLACK GREEN WHITE BARE Coti GREEN BLACK WHITE RED BARE Digi RED WHITE GREEN YELLOW GRAY Dillon CANISTER TENSION RED BLACK GREEN WHITE ORANGE COMPRESSION RED BLACK WHITE GREEN ORANGE Z-CELL RED BLACK WHITE GREEN ORANGE Electroscale RED BLACK GREEN WHITE BARE Epelsa RED BLACK GREEN WHITE BARE VIOLET GRAY Evergreen GREEN BLACK WHITE RED BARE Flintec PC1,PC2,PC6,RC1,SB4,SB5,SB6,SB14,SLB,UB1,UB6,SB10, PCB,BK2 GREEN BLACK WHITE RED YELLOW Force Measurement RED BLACK GREEN WHITE BARE General Sensor RED BLACK GREEN WHITE BARE Genisco RED BLACK GREEN WHITE BARE GSE RED BLACK WHITE GREEN BARE HBM SBF,SB3,USBU1T,Z6, H35 GREEN BLACK WHITE RED YELLOW BLC,BLF,JRT,PWS,RSC GREEN BLACK WHITE RED YELLOW PLC,B35, SBE RED BLACK GREEN WHITE YELLOW BBS GREEN BLACK WHITE RED BARE SP4, SP10,PW15,PWS,PWSM GREEN BLACK WHITE RED YELLOW ORANGE BLUE PW12,PW16,C16,PW15AH BLUE BLACK WHITE RED YELLOW GREEN GRAY Interface SSM,1200,3200 RED BLACK GREEN WHITE BARE Kubota RED WHITE GREEN BLUE YELLOW LeBow RED BLACK GREEN WHITE BARE Mettler Toledo WHITE BLUE GREEN BLACK ORANGE YELLOW RED National Scale GREEN BLACK WHITE RED YELLOW Nikkei RED BLACK GREEN WHITE BARE NCI RED BLACK WHITE GREEN BARE YELLOW BLUE NMB RED WHITE GREEN BLUE BARE Ormond RED BLACK GREEN WHITE BARE Pennsylvania ORANGE BLUE GREEN WHITE BARE Pesage Promotion BLUE WHITE RED BLACK YELLOW Philips RED BLUE GREEN GRAY BARE Revere Transducers 62HU,63HU,363,953,9523 RED BLACK GREEN WHITE BARE 92CC,93CC,24U,43U,263D,462,6762, 9102, 9103, 9123,9363,5102,5103, 5123, 5223, 5723, 9363 RED BLACK GREEN WHITE ORANGE 392B,642,652,692B2,BSP,HPS, USP1 GREEN BLACK WHITE RED BARE 792, 933, SHB, SSB GREEN BLACK WHITE RED CLEAR CP1,CSP1 GREEN BLACK WHITE RED ORANGE RLC PINK GRAY BROWN WHITE BARE Rice Lake Weighing RL20000,RL20000SS,RL20001HE,RL30000,RL75061,RL50500, RL70000SS,RL71000HE,RL75016HE RED BLACK GREEN WHITE BARE RL35023,RL35023S,RL35082,RL35083,RL39123,RL75223,RL90000,RLETB, RLETS,RLHSS,RLMK4 RED BLACK GREEN WHITE BARE RL39523,RL50210,RL56044,RL70000,RL75016,RL75016SS,RL75040A, RL75058,RL75060 RED BLACK GREEN WHITE BARE RLMK1 RED BLACK WHITE GREEN ORANGE YELLOW BLUE RLMK15,RLMK21 RED BLACK GREEN WHITE ORANGE RL1521A GREEN BLACK RED WHITE BARE RL40BBS,RLBLC,RLSB2,RLSB2L,RLSB2M,RLSB250,RLSSB,RLKIS, RL9000TWM,RL75114,RLSCA,RLBLP,RLSB2MLW GREEN BLACK WHITE RED BARE RL8C2P1SS,RLCSP1,RL75000SS,RL30745 GREEN BLACK WHITE RED ORANGE RL1380,RL1385,RLH35,RL30745,RLPC6 GREEN BLACK WHITE RED YELLOW RLPCB-60 GREEN BLACK WHITE RED YELLOW BLUE BROWN RL1010,RL1040,RL1140,RL1250,RL1260 GREEN BLACK RED WHITE BARE BLUE BROWN RLHBB,RLHTO BLUE BLACK WHITE RED BARE GREEN GRAY RL32155 WHITE BLUE GREEN BLACK ORANGE YELLOW RED Scaime BROWN GREEN YELLOW BLACK WHITE GRAY PINK Sensortronics RED BLACK GREEN WHITE BARE Sensotec RED BLACK WHITE GREEN BARE Strainsert RED BLACK GREEN WHITE BARE T-Hydronics RED BLACK GREEN WHITE BARE Tedea Huntleigh GREEN BLACK RED WHITE BARE BLUE BROWN Thames Side RED BLUE GREEN YELLOW BARE Toledo GREEN BLACK WHITE RED YELLOW Totalcomp RED BLACK GREEN WHITE BARE Transducers Inc. RED BLACK GREEN WHITE ORANGE Transcell RED BLACK GREEN WHITE Vishay BLH C2P1,C3P1,T2P1,T3P1 GREEN BLACK WHITE RED YELLOW Vishay Celtron PSD,SEB,LCD,CSB,DSR,LOC,SQB,STC,STCSS,DSR,CLB,HED,DLB,SQB,HSS RED BLACK GREEN WHITE BARE LPS RED BLUE GREEN WHITE BARE HOC,MOC GREEN BLACK RED WHITE BARE BLUE BROWN Vishay Sensortronics 60001,60008,60018,60030,60036,60040,60048,60048SS,60050,60051,60060, 60060-101,60063,65007,65016,65016SS RED BLACK GREEN WHITE BARE 65016W,65023,65023S,65023SS,65024,65040A,65040S, 65058S,65061A,65083,65083S,65114 RED BLACK GREEN WHITE BARE 6007, 60064 GREEN BLACK WHITE RED BARE 65088-1000,65088-1114 GREEN BLACK WHITE RED ORANGE Vishay Tedea-huntleigh 4157, 4158 RED BLACK GREEN WHITE BARE 3411, 3421 RED BLACK GREEN WHITE BARE BLUE BROWN 240, 1010, 1022, 1040, 1140, 1250, 1260, 1320,9010, 605, 1030, 1240, 1241, 1030,9010, 1030,1320,1510 GREEN BLACK RED WHITE BARE BLUE BROWN 355, 620, 3510 BLUE BLACK WHITE RED BARE GREEN GRAY Wiring Guide Central Carolina Scale, Inc 5393 Farrell Road Sanford NC 27330 PH: 919-776-7737 www.CentralCarolinaScale.com
  • 2. UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM Additional 20% off list price on orders over 1,000 NET Use Promo Code SBWP250 to receive discount st Valid through March 31 , 2013 Free freight on orders over 1,000 NET (not to be used with any other discounts/specials) Use Promo Code SBWP254 to receive discount st th Valid May 1 - 29 , 2013 Receive 10% off list price on any Brecknell Indicator order over 1,000 NET (to view indicators visit or your Brecknell Global Catalog) Use Promo Code SBWP255 to receive discount st st Valid July 1 - 31 , 2013 www.brecknellscales.com, www.brecknellscales.co.uk Brecknell Revere HBM Tedea Celtron Sensortronics Coti Artech Rice Lake Totalcomp BLH Fairbanks NMB Thurman Transcell Flintec Vishay BCL 1004 L6B 1004 L6C H2A H2D H2F H2J1 L3H H3 STC 60001-0221 COMPACT CISB H3C H3E H3F STC 60001,60036,RTI363 CISB H3G M363 STC 60001 20210 RL20000 / 20001 BSA / BSS STC H3G-Y 363 STR 60001 H3Y L3H 6362 L6D 640 PW6-2 1022 LPS 600g ~ 35kg CI-22 61022 RL1521 C2G1 4900 C2C1 C2G1 / LPS L6D4 PW6K 1022 LPS L6D5 L6E LPS L6E3 1263 L6F 1320 HOC L6G 672 LOC FAV L6H L6Q 650 1241 LPS 60kg ~ 200kg L6J L6J1 1006 L6J5 L6L L6N 642 SP4 1042 MT1041 RL1042 L6S 1030 L6T 652 1252 L6X L6Y H6G5 H6B H8 SB3 H8A H8B Z7 H8C 5123 3411 SQB 65023 CI-23 30310 RL35023 TSB SBS SQB H8K 5723 H9A H9B MDB H9C 5103 H9D 5203 DSR 65016 CI-16 70510 RL75016 DSR H9G H9G1 H9C-Y 5103 CSB 60058 CI-5103 70210 RL70000 H9D-Y 5203 H9H DLB 65040A BE40 80310 RL75040 TDE40 TSC840 DLB H9N 5303 4158 CLB 65058 CI-58 RL75058 CLB H10 H10A B3G M9363 STC 60050 B3G-Y 9363 STR 60050 B8D M9123 3410 SQB 65023 B8D-Y 9123 3421 SQB 65023 B8H ALC HVC 65083S BM6A 60064 B8K 9723 BM8D H35 BM8L 9113 BM8F 9523 BM8H ACB HLC HVC 65084 BM8G SSB SB3 CI-SB3 SS30610 RLSSB HM8 B9C-Y 9103 CI-5103-SSW RL7100HE B9D-Y 9203 DSR-HSS 65016W CI-16-SSW RL75016SS DSR-HSS B9E-Y 9223 B9F-Y 9323 DLB SS 65040S BE40-SSW RL75040A TSC840 B9N 9303 65058SS B9H-Y 9903 DLB SS 65040S BE40-SSW RL75040A B9J 9803 B9K 9423 HM9B HM9E-Y 5223 HED 65040-1127W CI-5223 80210 RL75223 TSC800 BM11 SHB Z6 355 HBB RLHBB HBB BM14A CSP 65088-1000 CP26S5 90310 RLCSP1 TCSP1 BM14C BM14G ASC BM14K C16 CP26S4 HM14C B14H CCC B14D H24L HM24M BM24R RLC PW12 1250 RL1250 PCB LOC B6Q 1241 S.S. Cross Reference Guide *Standard ground freight only *Valid for orders from inter-country stocking locations
  • 3. Brecknell 1000 Armstrong Drive Fairmont, Minnesota 56031 Toll Free: 800-637-0529 Telephone: 507-238-8702 Fax: 507-238-8271 Email: sales@brecknellscales.com www.brecknellscales.com Brecknell Foundry Lane Smethwick, West Midlands England B66 2LP Telephone: +44 (0) 845 246 6717 Fax: +44 (0) 845 246 6718 Email: sales@brecknellscales.co.uk www.brecknellscales.co.uk Brecknell 217 Brunswick Boulevard Pointe-Claire, Quebec Canada H9R 4R7 Toll Free: 800-268-1662 Telephone: 416-213-9900 Fax: 416-213-9960 Email: sales@brecknellscales.ca www.brecknellscales.ca Salter India Ltd. Plot #53, Sector 25, (Avery India Compound) Ballabgarh 121 004, Faridbad, Harvana (India) Telephone: 91-129-4094400 Fax: 91-129-4094591, 2234091 Email: sales@averyindia.net Www.averyindia.co.in CONTACT INFORMATION UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM COMPANY HISTORY Brecknell, part of Avery Weigh-Tronix, a proud member of the Illinois Tool Works (ITW) company, celebrated 250 years of customer commitment and history in 2011. Founded in 1761, under Salter Brecknell, Brecknell has grown to become a global leader in weighing solutions. Brecknell products are designed and constructed with focus on high-value solutions and accuracy for easy operation for all your weighing applications. Today, Brecknell products can be found for most weighing applications. The Brecknell global footprint and reach allows Brecknell to offer the highest quality of service an support to our customers. Fairmont, Minnesota Birmingham, England Montreal, Canada India
  • 4. Naming System of Load Cell / Force Transducers 2 1kg/cm 3m Naming System of Weighing Assembly UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK Material: H: Alloy Steel B: Stainless Steel L: Aluminum Accuracy: N3: NTEP 3000 Division N5: N10: G1: 0.1% Accuracy G2: 0.2% Accuracy G3: 0.3% Accuracy NTEP 5000 Division NTEP 10,000 Division C1: OIML Certified 1000 Division C2: OIML Certified 2000 Division C3: OIML Certified 3000 Division C3D: OIML Certified 2500 Division C3G: OIML Certified 4000 Division Sealing: No mark: Adhesive potted M: Hermetic welded XXXXX XX X XXXXX d: Digital load cell t: High temperature working Different Series of Appearance: A, B, C, D, E, E3, F, G, G5, H,H5, J, L, N, Q, OC3, W Thread: No mark: Metric Y: Imperial Type & Structure: 2: Spoke Type 3: S-Beam 6: Single Point 8: Single Shear Beam 9: Dual Shear Beam 11: Single Point with Bellow 14: Column type 16: Dual Parallel Beam Capacity: lb: Pounds (lb) K: Klb Kg: Kilograms t: Metric tons N: Newtons KN: Kilo Newtons MN: Million Newtons SE: Small Envelope LE: Large Envelope Material: H: Alloy Steel B: Stainless steel L: Aluminum Assembled Load Cell Type: 2: Spoke Type 3: S-Beam 6: Single Point 8: Single Shear Beam 9: Dual Shear Beam 11: Single Point with Bellow 14: Column type 16: Dual Parallel Beam Structure: J: Foot Y: Load button D: Plate L: Ring M: Mounting XX XX XXX XX / XX Series Number: Defined by number or letter Capacity Range Load Cell Protection Class Reference to National Standard of the Cover Protection Class System (P.R.C.) Equal to IEC529 Standard (International Electrotechnical Commission IP-6- Protection Level Class Description Meanings Experimental Method Achieved Protection Class 5 6 7 8 Adhesive sealed common load cell could achieve Cover sealed inner adhesive protected load cells could achieve Cover (or bellow) welded, inner adhesive protected load cells could achieve. Besides of oil-proof, water proof, it also can proof the common corrosive gas and medium Special required load cells could be customized Water- sprinkle proof Not be affected by the water-sprinkle from any direction in a short time Not be affected by the strong water-spray from any direction in a short time Not be affected by the inundating into water in a stated pressure and time Can dived into water for a long time Water- sprayed protection Soggy Proof Diving Proof Decided individually Inundate into 1 meter deep water for 30 minutes Continually spray water from any direction more than 15 minutes Continually spray water from any direction more than 15 minutes Can dived into water for a long time Dust-pro (dust could not be introduced to the inner part.) SoggyProtectionClass 2 1kg/cm 1m 1m International Protection
  • 5. Naming System of Load Cell / Force Transducers 2 1kg/cm 3m Naming System of Weighing Assembly UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK Material: H: Alloy Steel B: Stainless Steel L: Aluminum Accuracy: N3: NTEP 3000 Division N5: N10: G1: 0.1% Accuracy G2: 0.2% Accuracy G3: 0.3% Accuracy NTEP 5000 Division NTEP 10,000 Division C1: OIML Certified 1000 Division C2: OIML Certified 2000 Division C3: OIML Certified 3000 Division C3D: OIML Certified 2500 Division C3G: OIML Certified 4000 Division Sealing: No mark: Adhesive potted M: Hermetic welded XXXXX XX X XXXXX d: Digital load cell t: High temperature working Different Series of Appearance: A, B, C, D, E, E3, F, G, G5, H,H5, J, L, N, Q, OC3, W Thread: No mark: Metric Y: Imperial Type & Structure: 2: Spoke Type 3: S-Beam 6: Single Point 8: Single Shear Beam 9: Dual Shear Beam 11: Single Point with Bellow 14: Column type 16: Dual Parallel Beam Capacity: lb: Pounds (lb) K: Klb Kg: Kilograms t: Metric tons N: Newtons KN: Kilo Newtons MN: Million Newtons SE: Small Envelope LE: Large Envelope Material: H: Alloy Steel B: Stainless steel L: Aluminum Assembled Load Cell Type: 2: Spoke Type 3: S-Beam 6: Single Point 8: Single Shear Beam 9: Dual Shear Beam 11: Single Point with Bellow 14: Column type 16: Dual Parallel Beam Structure: J: Foot Y: Load button D: Plate L: Ring M: Mounting XX XX XXX XX / XX Series Number: Defined by number or letter Capacity Range Load Cell Protection Class Reference to National Standard of the Cover Protection Class System (P.R.C.) Equal to IEC529 Standard (International Electrotechnical Commission IP-6- Protection Level Class Description Meanings Experimental Method Achieved Protection Class 5 6 7 8 Adhesive sealed common load cell could achieve Cover sealed inner adhesive protected load cells could achieve Cover (or bellow) welded, inner adhesive protected load cells could achieve. Besides of oil-proof, water proof, it also can proof the common corrosive gas and medium Special required load cells could be customized Water- sprinkle proof Not be affected by the water-sprinkle from any direction in a short time Not be affected by the strong water-spray from any direction in a short time Not be affected by the inundating into water in a stated pressure and time Can dived into water for a long time Water- sprayed protection Soggy Proof Diving Proof Decided individually Inundate into 1 meter deep water for 30 minutes Continually spray water from any direction more than 15 minutes Continually spray water from any direction more than 15 minutes Can dived into water for a long time Dust-pro (dust could not be introduced to the inner part.) SoggyProtectionClass 2 1kg/cm 1m 1m International Protection
  • 6. Table of Contents - Numeric H2F H3 H3F B3G H3G BM3 L3V L6B L6C L6D L6D21 L6E B6E H6E L6E3 B6E3 L6F B6F H6F L6G B6G H6G H6G5 L6H5 L6J L6J1 L6L L6N B6N L6Q B6Q L6T L6W 38 39 40 BM6A BM6E BM6G 41 42 43 HM8 H8C HM8C 44 45 46 B8D BM8D H8H 47 48 49 50 51 BM8H H8Q B8Q B9B1 HM9B 52 55 56 53 54 57 58 59 60 61 62 63 65 64 66 67 68 69 70 71 72 B9C H9C HM9C B9D H9D B9E HM9E B9F B9H H9H B9N H9N BM11 HM11 BM14A BM14C HM14C BM14D BM14G HM14H BM14K Accessories 97 97 98 98 99 100 100 101 101 102 102 HL-3-001 HL-3-002 HL-3-003 HL-3-004 HL-3-005 HJ-8-201 BJ-8-202 HJ-8-203 BJ-8-205 BJ-8-206 BJ-8-207 103HJ-8-213 103 104 104 105 105 106 BJ-8-215 HJ-8-216 HJ-8-217 HJ-8-218 BJ-8-219 BJ-8-220 106 107 107 HD-8-301 HY-8-101 HY-8-102 108BY-8-104 108BY-8-106 111 112 HY-14-104 BY-14-105 110 111 BY-14-102 BY-14-103 Junction box 133 134 135 136 137 JB01 JB02 JB05A JB06 JB07 Transmitter 138 139 140 FD-3 FD-4 FD-5 5BM24R Miniature Sensors 73 74 75 76 78 79 80 81 82 1A 1B IF6-S 1HM 1R1-K 1V3-350 1X1 1Z 2A 83 84 85 2C1 2F 004-G 86 87 88 CF-1 Q45X10 Q45X6 89 90 91 Q70X5 Q84X5 S6400 92DB-1 771P Series 93DB-2 93DB-2 94FAB 95YA-6 96YA-7 109BY-14-101 H2F H3 H3F B3G H3G BM3 L3V L6B L6C L6D L6D21 L6E B6E H6E L6E3 B6E3 L6F B6F H6F L6G B6G H6G H6G5 L6H5 L6J L6J1 L6L L6N B6N L6Q B6Q L6T L6W 38 39 40 BM6A BM6E BM6G 41 42 43 HM8 H8C HM8C 44 45 46 B8D BM8D H8H 47 48 49 50 51 BM8H H8Q B8Q B9B1 HM9B 52 55 56 53 54 57 58 59 60 61 62 63 65 64 66 67 68 69 70 71 72 B9C H9C HM9C B9D H9D B9E HM9E B9F B9H H9H B9N H9N BM11 HM11 BM14A BM14C HM14C BM14D BM14G HM14H BM14K Accessories 97 97 98 98 99 100 100 101 101 102 102 HL-3-001 HL-3-002 HL-3-003 HL-3-004 HL-3-005 HJ-8-201 BJ-8-202 HJ-8-203 BJ-8-205 BJ-8-206 BJ-8-207 103HJ-8-213 103 104 104 105 105 106 BJ-8-215 HJ-8-216 HJ-8-217 HJ-8-218 BJ-8-219 BJ-8-220 106 107 107 HD-8-301 HY-8-101 HY-8-102 108BY-8-104 108BY-8-106 111 112 HY-14-104 BY-14-105 110 111 BY-14-102 BY-14-103 Junction box 133 134 135 136 137 JB01 JB02 JB05A JB06 JB07 Transmitter 138 139 140 FD-3 FD-4 FD-5 5BM24R Miniature Sensors 73 74 75 76 78 79 80 81 82 1A 1B IF6-S 1HM 1R1-K 1V3-350 1X1 1Z 2A 83 84 85 2C1 2F 004-G 86 87 88 CF-1 Q45X10 Q45X6 89 90 91 Q70X5 Q84X5 S6400 92DB-1 771P Series 93 DB-2 93 DB-2 94FAB 95YA-6 96YA-7 109BY-14-101 Table of Contents - Alpha
  • 7. Table of Contents - Numeric H2F H3 H3F B3G H3G BM3 L3V L6B L6C L6D L6D21 L6E B6E H6E L6E3 B6E3 L6F B6F H6F L6G B6G H6G H6G5 L6H5 L6J L6J1 L6L L6N B6N L6Q B6Q L6T L6W 38 39 40 BM6A BM6E BM6G 41 42 43 HM8 H8C HM8C 44 45 46 B8D BM8D H8H 47 48 49 50 51 BM8H H8Q B8Q B9B1 HM9B 52 55 56 53 54 57 58 59 60 61 62 63 65 64 66 67 68 69 70 71 72 B9C H9C HM9C B9D H9D B9E HM9E B9F B9H H9H B9N H9N BM11 HM11 BM14A BM14C HM14C BM14D BM14G HM14H BM14K Accessories 97 97 98 98 99 100 100 101 101 102 102 HL-3-001 HL-3-002 HL-3-003 HL-3-004 HL-3-005 HJ-8-201 BJ-8-202 HJ-8-203 BJ-8-205 BJ-8-206 BJ-8-207 103HJ-8-213 103 104 104 105 105 106 BJ-8-215 HJ-8-216 HJ-8-217 HJ-8-218 BJ-8-219 BJ-8-220 106 107 107 HD-8-301 HY-8-101 HY-8-102 108BY-8-104 108BY-8-106 111 112 HY-14-104 BY-14-105 110 111 BY-14-102 BY-14-103 Junction box 133 134 135 136 137 JB01 JB02 JB05A JB06 JB07 Transmitter 138 139 140 FD-3 FD-4 FD-5 5BM24R Miniature Sensors 73 74 75 76 78 79 80 81 82 1A 1B IF6-S 1HM 1R1-K 1V3-350 1X1 1Z 2A 83 84 85 2C1 2F 004-G 86 87 88 CF-1 Q45X10 Q45X6 89 90 91 Q70X5 Q84X5 S6400 92DB-1 771P Series 93DB-2 93DB-2 94FAB 95YA-6 96YA-7 109BY-14-101 H2F H3 H3F B3G H3G BM3 L3V L6B L6C L6D L6D21 L6E B6E H6E L6E3 B6E3 L6F B6F H6F L6G B6G H6G H6G5 L6H5 L6J L6J1 L6L L6N B6N L6Q B6Q L6T L6W 38 39 40 BM6A BM6E BM6G 41 42 43 HM8 H8C HM8C 44 45 46 B8D BM8D H8H 47 48 49 50 51 BM8H H8Q B8Q B9B1 HM9B 52 55 56 53 54 57 58 59 60 61 62 63 65 64 66 67 68 69 70 71 72 B9C H9C HM9C B9D H9D B9E HM9E B9F B9H H9H B9N H9N BM11 HM11 BM14A BM14C HM14C BM14D BM14G HM14H BM14K Accessories 97 97 98 98 99 100 100 101 101 102 102 HL-3-001 HL-3-002 HL-3-003 HL-3-004 HL-3-005 HJ-8-201 BJ-8-202 HJ-8-203 BJ-8-205 BJ-8-206 BJ-8-207 103HJ-8-213 103 104 104 105 105 106 BJ-8-215 HJ-8-216 HJ-8-217 HJ-8-218 BJ-8-219 BJ-8-220 106 107 107 HD-8-301 HY-8-101 HY-8-102 108BY-8-104 108BY-8-106 111 112 HY-14-104 BY-14-105 110 111 BY-14-102 BY-14-103 Junction box 133 134 135 136 137 JB01 JB02 JB05A JB06 JB07 Transmitter 138 139 140 FD-3 FD-4 FD-5 5BM24R Miniature Sensors 73 74 75 76 78 79 80 81 82 1A 1B IF6-S 1HM 1R1-K 1V3-350 1X1 1Z 2A 83 84 85 2C1 2F 004-G 86 87 88 CF-1 Q45X10 Q45X6 89 90 91 Q70X5 Q84X5 S6400 92DB-1 771P Series 93 DB-2 93 DB-2 94FAB 95YA-6 96YA-7 109BY-14-101 Table of Contents - Alpha
  • 8. H2A · Capacities:1MN~ 5MN · Alloy steel construction · High reliability and long life span MN 1/2/3/4/5 G2 0.2% 0.05% 0.1% 0.1% ≥2.0 1072±5 1050±5 ≥5000(50VDC) 1.0 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 Output (+) Green Input (-) Black Output (-) White Input (+) Red Wiring: hielded, 4 conductor cable: Φ5mm Standard cable length: 5m S Capacity(MN) Dimension D D1 D2 H H1 1 2 3 4 5 41 (1.61) 60 (2.36) 73 (2.87) 92 (3.62) 115 (4.53) 260 (10.24) 290 (11.42) 330 (12.99) 400 (15.75) 400 (15.75) 200 (7.87) 225 (8.86) 251 (9.88) 296 (11.65) 307 (12.09) 80 (3.15) 104 (4.09) 123 (4.84) 132 (5.20) 132 (5.20) 10 (0.39) 10 (0.39) 10 (0.39) 10 (0.39) 10 (0.39) Specifications ΦD 4-M16 depth 20(0.79) Equipartion H ΦD1 ΦD2 H1 10(0.39) 1 · H2A load cells are available in the manifold accurate measurement in the capacities 1MN to 5MN. · Alloy steel,surface bluing treatment, spray painted, oil-proof, waterproof and anti-corrosion, suitable for groundsill measuring and other engineering measuring fields. · Spoke type, easy installation, suitable for special force measuring equipments. · Safety and anti-explosive product, can be used in atrocious environments and hazardous areas. Capacity Accuracy Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) Outline Dimension mm(inch) Features UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK G3 0.3% 0.05% 0.2% 0.2%
  • 9. Outline Dimension mm(inch) H2D · H2D load cells are available for manifold accurate measurement in the capacities 5t~ 20t. · Alloy steel, sealed by adhesive, oil-proof, waterproof and anti-corrosion, suitable for all kinds of environments. · Spoke type, easy installation, suitable for crane scale, hopper scale and other electronic weighing devices. · Safe and anti-explosive product, can be used in atrocious environment and hazardous areas. · Capacity: 5t~ 20t · Alloy steel construction · High accuracy 5/10/20 C2 2000 Emax/5000 ≤±0.030 ≤±0.023 ≤±0.017 ≤±0.029 2.0±0.008 750±10 700±7 ≥5000(50VDC) 1.0 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 Output (+) Green Input (-) Black Output (-) White Input (+) Red Wiring: Five-wire connector hielded, 4 conductor cable: Φ5mm Standard cable length: 5m(5t,10t),10m(20t) S D D1 M H Capacityt() Dimension (mm) 5 10 20 L 83 (3.27) 128 (5.04) 45 (1.77) M24×2 8 (0.31) 150 (5.91) 160 (6.03) 60 (2.36) M39×2 30 (1.18) 220 (8.66) 200 (7.78) 80 (2.99) M60×2 60 (2.36) t Specifications M 25 (0.98) L H 52 (2.05) ΦD ΦD1 2 Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) Features CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  • 10. HM2D4 Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload tCapacity C3 2000 Emax/5000 ≤±0.030 ≤±0.024 ≤±0.017 ≤±0.023 2.0±0.002 350±3 351±2 ≥5000(50VDC) 1.0 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 Features · Capacity: 0.5t~ 50t · High accuracy · Alloy steel construction · Low profile Outline Dimension mm(inch) Wiring: Shielded, 6 conductor cable: Φ5.6mm Standard cable length: 5m · · · HM2D4 load cells are available for manifold accurate measurement in the capacities 0.5t~ 20t. Alloy steel, completely welded, oil-proof, waterproof and anti-corrosive gas and medium, suitable for all kinds of environments. Spoke type, suitable for electronic truck scales, hopper scales, automotive testing equipments, and other electronic weighing or force measuring fields. 0.5/1/2/3/5/10/20/50 Output (+) White Sense (-) Blue Output (-) Red Input (+) Green Input (-) Black Sense (+) Yellow 0.5t~2t D 105 (4.13) 28 (1.10) 70 (2.76) Dimension (mm) Capacity(t) 3t,5t 10t,20t D1 H M 120 (4.72) 155 (6.10) 33 (1.3) 60.5 (2.38) 90 (3.54) 80 (3.15) M14×2 M20×1.5 M32×2 IP68 50 (1.97) ΦD1 25 (0.98) 30 (0.18) H ΦD M Specifications 3 nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 50t 200 (7.87) 75 (2.95) 120 (4.72) M45×3
  • 11. H2F · H2F load cells are available for manifold accurate measurement in the capacities 1t~ 50t. · Alloy steel, potted with adhesive inside, oil-proof, waterproof and anti-corrosion, suitable for all kinds of environments. · Spoke type, easy installation, suitable for electronic truck scales, hopper scales and other electronic weighing devices. · Safe and anti-explosive product, can be used in atrocious environment and hazardous areas. Features · Capacity: 1t~ 50t · Alloy steel construction · High accuracy C1 1000 Emax/3000 ≤±0.050 ≤±0.038 ≤±0.028 ≤±0.047 C2 2000 Emax/5000 ≤±0.030 ≤±0.023 ≤±0.017 ≤±0.029 2.0±0.01 770±30 700±5 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 Output (+) Blue Sense (-) Black Output (-) White Input (+) Red Input (-) Yellow Sense (+) Brown Wiring: hielded, 6 conductor cable: Φ6mm Standard cable length: 3m(1~3t),4m(5~10t),15m(15~50t) S Capacity(t) Dimension(mm) Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload t Specifications D D1 D2 H H1 H2 WL 1 2 3 5 10 15 20 30 50 115 (4.53) 22 (0.87) 86 (3.39) 43 (1.69) 12 (0.47) 5 (0.2) 8 (0.31) 8.4 (0.33) 120 (4.72) 26 (1.02) 128 (5.04) 160 (6.3) 128 (5.04) 194 (7.64) 220 (8.66) 230 (9.06) 264 (10.39) 20 (0.79) 20 (0.79) 40 (1.57) 42 (1.65) 44 (1.73) 48 (1.89) 52 (2.05) 90 (3.54) 100 (3.94) 100 (3.94) 120 (4.72) 154 (6.06) 170 (6.69) 188 (7.4) 214 (8.43) 45 (1.77) 46 (1.81) 63 (2.48) 73 (2.87) 78 (3.07) 90 (3.54) 68 (2.68) 46 (1.81) 12 (0.47) 8 (0.31) 8 (0.31) 15 (0.59) 20 (0.79) 22 (0.87) 25 (0.98) 30 (1.18) 5 (0.2) 5 (0.2) 10 (0.39) 10 (0.39) 10 (0.39) 10 (0.39) 10 (0.39) 5 (0.2) 8 (0.31) 7 (0.28) 7 (0.28) 10 (0.39) 12 (0.47) 12 (0.47) 12 (0.47) 12 (0.47) 8.4 (0.33) 10.4 (0.41) 10.4 (0.41) 10.4 (0.41) 12.4 (0.49) 12.4 (0.49) 12.4 (0.49) 12.4 (0.49) Accessory · HM-2-401 · BM-2-402 ΦD2 H2 ΦD H1 4-W 4-L 45° 45° ΦD1 4 nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) Outline Dimension mm(inch) CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM H 1/2/3/5/10/15/20/30/50
  • 12. · · hazardous BM24R applied a ring type, suitable for all kinds of platform scales and dynamic weighing system. Stainless steel, Hermetically sealed IP68,low profile load cell for all kinds of applications. Features · Capacity: 60kg-60t High accuracy OIML Cert. No.: R60/2000-NL-11.21 NTEP Cert. No.: 11-103A1 · · · BM24R BM24R 60kg-280kg Accessory: BJ-24-202 BM-24-401 BM24R 250kg-13t BJ-24-203 BJ-24-204 BM-24-402 BM-24-403 BM24R-28t-60t BJ-24-205 Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance C3 3000 Emax/10000 ≤±0.0230 ≤±0.0245 ≤±0.0117 ≤±0.0140 Specifications 60kg / 130kg / 250kg / 280kg / 500kg / 1t / 2t / 3.5t / 5t/ 10t / 13t / 28t / 60t nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (%FS) 60kg / 130kg / 280kg 1.0±0.1 250kg 1.75±0.1 2.0±0.1 60kg / 130kg / 280kg 1260±100 500kg 60t~ 250kg / 500kg 10t~ 1100±100 13t 1200±100 28t 60t 1075±100 1350±100 60kg / 130kg / 280kg 1020±0.5 250kg / 500kg 10t~ 13t 28t 60t 1025±25 1000±0.5 930±0.5 1175±0.5 Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) ≥5000(50VDC) 1.0 -10 +40~ -30 +70~ 5 12(DC)~ 15(DC) 150 300 Nm 60kg / 130kg / 280kg 8 250kg / 500kg 10t~ 13t 28t 60t 10 - - - Recommended torque on fixation bolts Protection class IP68 Outline Dimension mm(inch) Wiring: S ± hielded, 4 conductor cable: Φ6.2mm 0.1mm Dim. Capacity ΦA ΦB C D E ΦF G H I J ΦK SR 60kg / 130kg / 280kg 63 15.1 22 11 60 54 6 10 Φ3.2 -- -- -- 0.25t/0.5t/1t 80 19 25 12.5 65 71 10 18 M10 1 25 -- 2t / 3.5t 80 19 30 12.5 65 71 10 18 Φ15 6 25 -- 10t 95 26 35 12.5 72 75 20.7 31.2 -- -- 29 -- 13t 95 26 35 20 85 79.5 20 31 -- -- 29 -- 28t 120 35.9 46 25 94 102 -- 53 -- -- -- 400 60t 140 47.9 62 34 104 124 -- 69 -- -- -- 600 Capacity Cable length 60kg 3m 130kg 250kg 280kg 500kg 1t 2t 6m3.5t 5t 10t 15m 13t 28t 60t 5 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK To order call (919) 776-7737 or visit www.CentralCarolinaScale.com
  • 13. 25kg-5t L 2-M H W1 0.1-20klb H1 2Places 7.5t-30t L 2-M H H1 2Places H3 Accuracy Approvals Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload t lb Capacity 25kg/50kg/100kg/150kg/200kg/250kg/300kg/500kg/600kg/750kg/1t/1.5t/2t/2.5t/3t/5t/7.5t/10t/15t/20t/30t 100/150/200/250/300/500/750/1K/1.5K/2K/2.5K/3K/5K/10K/15K/20K C3 OIML R60 C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 N10 10000 Emax/10000 ≤±0.20 ≤±0.020 ≤±0.014 ≤±0.017 2.0±0.004(Metric) 3.0±0.008(Imperial) 350±3.5 351±2.0 ≥5000(50VDC) 1.5(Metric) 1.0(Imperial) -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 · H3 load cells are available in the capacities 25kg~ 30t and 100lb~ 20Klb. · Alloy steel, sealed by adhesive inside, oil-proof, waterproof and anti-corrosion, suitable for all kinds of environments. · S beam design, tension and/or compression loading possible, easy installation, suitable for crane scale, mechanical conversion scale, hopper scale and other electronic weighing devices. · Safe and anti-explosive product, can be used in atrocious environment and hazardous areas. Features · Capacity: 25kg~ 30t ; 100lb~ 20Klb · High accuracy · Alloy steel construction · Low profile · OIML Certificates No:R60/2000-CN-00.01 · PTB Approval No:D09-03.18 Revision 2 · NTEP Certificates No:CC06-099A1 Accessory · HL-3-001 · HL-3-002 · HL-3-003 · HL-3-004· HL-3-005 Specifications Outline Dimension mm(inch) Wiring: Shielded, 4 conductor cable: Φ5mm Standard cable length: 3m(0.025t~0.75t), 6m(1t~30t)(0.1klb~20klb) Output (+) Green Input (-) Black Output (-) White Input (+) Red W1 W MCapacity Dimension(mm) H1±0.4 25kg~50kg 0.1t~0.15t 0.2t~0.75t 1t~1.5t 2t~5t 7.5t~10t 15t~20t 30t 100lb~300lb 500lb 0.75klb~1.5klb 2klb~2.5klb 3klb 5klb~10klb 15klb 20klb 15.7(0.62) 10.16(0.4) 15.3(0.60) 15.3(0.60) 12.1(0.48) 76.2(3.0) 76.2(3.0) 76.2(3.0) 76.2(3.0) 101.6(4.0) 175(6.89) 200(7.89) 230(9.06) 63.5(2.5) 63.5(2.5) 63.5(2.5) 63.5(2.5) 101.6(4.0) 101.6(4.0) 139.7(5.5) 177.8(7.0) 50.8(2.0) 50.8(2.0) 50.8(2.0) 50.8(2.0) 76.2(3.0) 125(4.92) 160(6.3) 190(7.48) 50.8(2.0) 50.8(2.0) 50.8(2.0) 50.8(2.0) 76.2(3.0) 76.2(3.0) 101.6(4.0) 127(5.0) 12.7(0.5) 19.0(0.75) 19.0(0.75) 25.4(1.0) 25.4(1.0) 50(1.97) 60(2.36) 80(3.15) 12.7(0.5) 19.05(0.75) 19.05(0.75) 25.4(1.0) 25.4(1.0) 25.4(1.0) 31.75(1.25) 50.8(2.0) 16.1(0.63) 22.4(0.88) 22.4(0.88) 28.8(1.13) 28.8(1.13) / / / 15.9(0.63) 22.25(0.88) 22.25(0.88) 28.6(1.13) 28.6(1.13) 28.6(1.13) 34.95(1.38) 54(2.13) M8 M10×1.5 M10×1.5 M12×1.75 M20×1.5 M33×3 M42×3 M42×3 1/4-28UNF 1/2-20UNF 1/2-20UNF 1/2-20UNF 1/2-20UNF 3/4-16UNF 1-14UNS 20(0.79) 40.2(1.58) 51(2.01) 57.5(2.26) 15.24(0.6) 31(1.22) 39.9(1.57) 15.24(0.6) W W1 5 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin H L 6 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM Central Carolina Scale, Inc 5393 Farrell Road Sanford NC 27330 PH: 919-776-7737 www.CentralCarolinaScale.com
  • 14. H3F Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload t lb Capacity C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 N5 5000 Emax/5000 ≤±0.020 ≤±0.020 ≤±0.017 ≤±0.020 3.0±0.008 350±3.5 351±2.0 ≥5000(50VDC) 1.0 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 · H3F load cells are available in the capacities 0.1t~ 5t and 250lb~ 20Klb. · Alloy steel, sealed by adhesive inside, oil-proof, waterproof and anti-corrosion, suitable for all kinds of environments. · S beam design, tension and/or compression loading possible, easy installation, suitable for crane scale, mechanical conversion scale, hopper scale and other electronic weighing devices. · Safe and anti-explosive product, can be used in atrocious environment and hazardous areas. Features · Capacity: 0.1t~ 5t;250lb~ 20Klb · High accuracy · Alloy steel construction · Low profile · NTEP Certificates No:CC06-099A1 Accessory · HL-3-001 · HL-3-002 · HL-3-003 · HL-3-004· HL-3-005 Specifications Outline Dimension mm(inch) 100kg/250kg/500kg/750kg/1t/1.5t/2t/2.5t/5t 250/500/750/1K/1.5K/2K/2.5K/3K/5K/7.5K/10K/15K/20K Capacity Dimension mm 100kg 250kg 500kg 750kg 1000kg 1500kg 2000kg 2500kg 5000kg 250lb 500lb 750lb 1klb 1.5klb 2klb 2.5klb 3klb 5klb 7.5klb 10klb 15klb 20klb 76.2(3) 76.2(3) 76.2(3) 76.2(3) 76.2(3) 76.2(3) 108(4.25) 108(4.25) 108(4.25) 76.2(3) 76.2(3) 76.2(3) 76.2(3) 76.2(3) 76.2(3) 76.2(3) 76.2(3) 108(4.25) 108(4.25) 108(4.25) 140(5.51) 177.8(7) 25.4(1.0) 25.4(1.0) 25.4(1.0) 25.4(1.0) 31.8(1.25) 31.8(1.25) 31.8(1.25) 31.8(1.25) 31.8(1.25) 19(0.75) 25.4(1.0) 25.4(1.0) 25.4(1.0) 25.4(1.0) 31.8(1.25) 31.8(1.25) 31.8(1.25) 31.8(1.25) 31.8(1.25) 31.8(1.25) 38.1(1.31) 50.8(2.0) 19(0.75) 19(0.75) 19(0.75) 19(0.75) 25.4(1) 25.4(1) 25.4(1) 25.4(1) 25.4(1) 12.7(0.5) 19(0.75) 19(0.75) 19(0.75) 19(0.75) 25.4(1) 25.4(1) 25.4(1) 25.4(1) 25.4(1) 25.4(1) 31.8(1.25) 49.3(1.94) 50.8(2) 50.8(2) 50.8(2) 50.8(2) 50.8(2) 50.8(2) 76.2(3) 76.2(3) 76.2(3) 50.8(2) 50.8(2) 50.8(2) 50.8(2) 50.8(2) 50.8(2) 50.8(2) 50.8(2) 76.2(3) 76.2(3) 76.2(3) 100(3.94) 125.5(4.94) 15.8(0.62) 15.12(0.6) 14.2(0.56) 13.46(0.53) 13.24(0.52) 12.1(0.48) 26.7(1.05) 25.48(1) 20.26(0.8) 15.69(0.62) 15.25(0.6) 14.95(0.59) 14.4(0.57) 13.75(0.54) 13.4(0.53) 13.03(0.51) 12.39(0.49) 27.18(1.07) 25.78(1.01) 23.88(0.94) 31(1.22) 39.9(1.57) M10×1.5 M12×1.75 M12×1.75 M12×1.75 M12×1.75 M12×1.75 M18×1.5 M18×1.5 M18×1.5 3/8-24UNF-2B 1/2-20UNF-2B 1/2-20UNF-2B 1/2-20UNF-2B 1/2-20UNF-2B 1/2-20UNF-2B 1/2-20UNF-2B 1/2-20UNF-2B 3/4-16UNF-2B 3/4-16UNF-2B 3/4-16UNF-2B 1-14UNS-2B 1-1/4-12UNF-2B Output (+) Green Input (-) Black Output (-) White Input (+) Red Shielded, 4 conductor cable: Φ5mm Standard cable length: 6m Wiring: H W W1 L H1 MW1 H 2-M-6H L H1 (2Places) W nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) 7 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK
  • 15. B3G t lb Capacity C3 OIMLR60 C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 N3 3000 Emax/3000 ≤±0.030 ≤±0.030 ≤±0.020 ≤±0.025 3.0±0.008 430±60 351±2.0 ≥5000(50VDC) 1.0 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 Features · Capacity:50kg~ 10t ;50lb~ 20Klb · · · · R60/2000-CNI-06.02 · D09-06.07 · NTEP Certificates No:CC06-099A1 High accuracy Stainless steel construction Low profile OIML Certificates No: PTB Approval No: Accessory · HL-3-001 · HL-3-002 · HL-3-003 · HL-3-004· HL-3-005 Specifications Outline Dimension mm(inch) Wiring: Shielded, 4 conductor cable: Φ5mm Standard cable length: 6m Output (+) Green Input (-) Black Output (-) White Input (+) Red 50kg/100kg/250kg/500kg/1t/2.5t/5t/7.5t/10t 50/75/100/150/200/250/300/500/750/1K/1.5K/2K/2.5K/3K/5K/10K/15K/20K · B3G load cells are available in the capacities 50kg~ 10t and 50lb~ 20Klb. · Stainless steel, sealed by adhesive inside, oil-proof, waterproof and anti-corrosion, suitable for all kinds of environments. · S beam design, tension and/or compression loading possible, easy installation, suitable for crane scale,mechanical conversion scale, hopper scale and other electronic weighing devices. · Safe and anti-explosive product, can be used in atrocious environment and hazardous areas. 50.8 (2.0) 11.68 (0.46) 15.06 (0.59) 50.8 (2.0) 18.03 (0.71) 21.4 (0.84) 50.8 (2.0) 24.38 (0.96) 27.76 (1.09) Dimension mm M8 1/4-28UNF 74.68 (2.94) 87.38 (3.44) 37.08 (1.46) 40.46 (1.59) 112.78 (4.44) 42.93 (1.69) 46.31 (1.82) M12 1/2-20UNF M12 1/2-20UNF M20×1.5 1/2-20UNF M20×1.5 3/4-16UNF M24×2 1-14UNS 60.96 (2.4) 139.7 (5.5) 177.8 (7.0) 99.06 (3.9) 30.74 (1.21) 34.12 (1.34) Capacity L H WW1 M H1 50kg,100kg 50lb~300lb 250kg,500kg 500lb~1.5 lb 1t 2,2.5klb 2.5t 3klb 5t 10klb 7.5t 15klb 10t 20klb k 76.2 (3.0) 5klb 76.2 (3.0) 60.96 (2.4) 60.96 (2.4) 99.06 (3.9) 99.06 (3.9) 24.38 (0.96) 24.38 (0.96) 27.76 (1.09) 27.76 (1.09) M30×2 -12UNS1-1 4 3/4-16UNF 8.89 (0.35) 13.97 (0.55) 18.37(0.72) 15.75(0.62) 27.5 (1.08) 39.9 (1.57) 13.97 (0.55) W2-M L H H1 2Places W1 7 nmax vmin Accuracy Approvals Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) 8 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM N10 10000 Emax/10000 ≤±0.020 ≤±0.020 ≤±0.014 ≤±0.017
  • 16. H 2-M L H1 2Places W H3G Features · Capacity: 50kg~ 10t ; 50lb~ 20Klb · High accuracy · Alloy steel construction · Low profile · NTEP Certificates No:CC06-099A1 · OIML Certificates No:R60/2000-NL1-10.30 Accessory · HL-3-001 · HL-3-002 · HL-3-003 · HL-3-004· HL-3-005 Outline Dimension mm(inch) Wiring: Shielded, 4 conductor cable: Φ5mm Standard cable length: 6m Output (+) Green Input (-) Black Output (-) White Input (+) Red · H3G load cells are available in the capacities 50kg~ 7.5t and 50lb~ 20Klb. · Alloy steel, sealed by adhesive inside, oil-proof, waterproof and anti-corrosion, suitable for all kinds of environments. · S beam design, tension and/or compression loading possible, easy installation, suitable for crane scale,mechanical conversion scale, hopper scale and other electronic weighing devices. · Safe and anti-explosive product, can be used in atrocious environment and hazardous areas. 50.8 (2.0) 12.7 (0.5) 16.07 (0.63) 50.8 (2.0) 19.05 (0.75) 22.43 (0.88) 50.8 (2.0) 25.4 (1.0) 28.78 (1.13) Dimension mm M8 1/4-28UNF 101.6 (4.0) 31.75 (1.25) 35.13 (1.38) 127 (5.0) 50.8 (2.0) 54.6 (2.15) M12 1/2-20UNF M12 1/2-20UNF M20×1.5 1/2-20UNF M20×1.5 3/4-16UNF M24×2 1-14UNS 63.5 (2.5) 139.7 (5.5) 177.8 (7.0) 25.4 (1.0) Capacity L H WW1 M H1 50kg,100kg 50lb~300lb 200kg,500kg 500lb~1.5klb 1t 2,2.5klb 2.5t 3klb 5t 5klb,10klb 7.5t 15klb 76.2 (3.0) 25.4 (1.0) -12UNF1-1 4 10.16 (0.4) 15.2 (0.6) 20(0.79) 15.24(0.6) 39.9 (1.57) 76.2 (3.0) 63.5 (2.5) 63.5 (2.5) 101.6 (4.0) 101.6 (4.0) 28.78 (1.13) 28.78 (1.13) 20klb 30(1.18) 31(1.22) Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload t lb Capacity C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 N3 3000 Emax/3000 ≤±0.030 ≤±0.030 ≤±0.020 ≤±0.025 3.0±0.008 430±60 351±2.0 ≥5000(50VDC) 1.0 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 Specifications 0.05/0.1/0.25/0.5/1/2.5/5/7.5 50/75/100/150/200/250/300/500/750/1K/1.5K/2K/2.5K/3K/5K/10K/15K/20K W1 8 nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) 9 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK N10 10000 Emax/10000 ≤±0.020 ≤±0.020 ≤±0.014 ≤±0.017
  • 17. W 86 92(3.62) Φ99 2-M-6H Features · Capacity:1t~ 7.5t · High accuracy · Stainless steel construction · Low profile · PTB Approval NO:D09-08.01 · NTEP Certificates No:CC06-099A1 Accessory · HL-3-001 · HL-3-002 · HL-3-003 · HL-3-004· HL-3-005 Outline Dimension mm(inch) Wiring: Shielded, 4 conductor cable: Φ5mm Standard cable length: 3m(500kg), 6m(1t~7.5t) Output (+) Green Input (-) Black Output (-) White Input (+) Red · Bm3 load cells are available in the capacities 1t~ 7.5t. · Stainless steel, hermetically welded, oil-proof, waterproof and anti-corrosion, suitable for all kinds of environments. · S beam design, tension and/or compression loading possible, easy installation, suitable for electronic crane scale, hopper scale and other electronic weighing devices. · Safe and anti-explosive product, can be used in atrocious environment and hazardous areas. Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload tCapacity C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.004 350±3.5 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 Specifications 1/2/3/4/5/6 W 32(1.26) 32(1.26) 32(1.26) Dimension(mm) 36(1.42) 50(1.97) 50(1.97) M H Capacity (t) 1.0 2.0-2.5t 3.0 4.0 5.0 6.0 M20×1.5 M20×1.5 M20×1.5 M24×2 M24×2M12×1.75 25(0.98)25(0.98) 25(0.98) 25(0.98) 24(0.94)24(0.94) BM3 H 2Places nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) Approvals OIML R60 C3 (3.90) (3.39) 10 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  • 18. L3V Features · Capacity: 200kg~500kg · Aluminum S beam · High accuracy · High reliability kg · L3V load cells are available in the capacities 200kg and 500kg. · Aluminum material, sealed with silicon adhesive, surface spraying plastic with good resistance against corrosion. · Integral construction, easy installation. · Suitable for textile machinery measuring and other electronic measuring fields. Wiring: Output (+) Green Input (-) Black Output (-) White Input (+) Red Shielded, 4 conductor cable: Φ5.3±0.2mm, and cable jacket is PVC. Standard cable length: 2.6±0.1m IP65 200/500 C2 2000 Emax/5000 ≤±0.030 ≤±0.024 ≤±0.03 ≤±0.5 2.3±0.2 410±30 351±2 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 64(2.52) 80(3.15) 25(0.98) 2-M12 15 (0.59) 15 (0.59) Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Specifications 102 nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) Outline Dimension mm(inch) 11 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK
  • 19. L6B Features · Capacity: 0.3kg~ 3kg · High accuracy · Max. platform size: 200×200mm · 0.3kg~ 3kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic balance and other electronic weighing devices. L6B load cells are available in the capacities Wiring: Output (+) Green Input (-) Black Output (-) White Input (+) Red Shielded, 4 conductor cable, and cable jacket is PVC. Cable length: 0.45±0.05m Cable diameter: 3±0.2mm 7(0.28) 2 Places 5(0.20) 2 Places 33(1.30) 4-M3 Depth 10(0.39) 10(0.39) 17(0.67)17(0.67) 110(4.33) IP65 11 Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 ≤±0.030 0.9±0.1 406±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 2500 Emax/5000 ≤±0.020 ≤±0.021 ≤±0.028 Specifications 0.3/0.6/1.2/3 0.02% /100mmload value nmax vmin Outline Dimension mm(inch) (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) Underport Depth 15(0.38) 12 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  • 20. Outline Dimension mm(inch) L6C Features · Capacity: 3kg~ 50kg · High accuracy · Max. platform size: 450×450mm · Installed screw request M8, 8.8 class, with oiled screw, torque 25Nm. Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3D ≤±0.030 2500 Emax/5000 ≤±0.020 ≤±0.021 ≤±0.028 Specifications · L6C load cells are available in the capacities 3kg~ 50kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for pricing scale, counting scale, electronic balance and other electronic weighing devices. Wiring: 406±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02% /100mmload value 3/5/8/20/30/50 Input (+) Shield Output (-) Input (-) Output (+) Shielded, 5 conductor ribbon cable. Cable length: 0.35±0.05m The shield is connected to the element. IP65 2-M8-6H Through 125(4.92) 45(1.77) 29(1.14) 24(0.94) 45(1.77) 27 (1.06) 8 (0.31) 2-M8 Depth 15(0.59) 2 Places Limiting plate 2 nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) 1.9±0.2 13 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK
  • 21. L6D Features · Capacity: 2.5kg~ 50kg · High accuracy · Max. platform size: 250×350mm · OIML Certificates No:R60/2000-CN-00.05 Revision 1 · PTB Approval No:D09-03.20 Revision 1 · NTEP Certificates N0: CC 11-012 Capacity Accuracy Approvals Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 OIML R60 C3 3000 Emax/7000 ≤±0.020 ≤±0.0167 ≤±0.0175 ≤±0.020 2.0±0.2 406±6/1065±15 350±3/1000±10 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm Specifications · L6D load cells are available in the capacities 2.5kg~ 50kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for pricing scale, platform scale and other electronic weighing devices. 2.5/3/5/6/8/10/15/20/30/35/40/50 Output resistance Input Output + +- - R R W B G G W B1000(Ω) Wiring: Shield Transparent 350(Ω) hielded, 4 conductor cable, and cable jacket is PVC. Cable length: 0.40±0.05m Cable diameter: 3.8±0.2mm S Output (+) Green Input (-) Black Output (-) White Input (+) Red IP65 15(0.59) 25(0.98) 2 Places 301.18() 130(5.21) 22(0.87) 2Places 2 Places 12(0.47) 4-M6-6H Through Outline Dimension mm(inch) nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) 14 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  • 22. Outline Dimension mm(inch) L6D21 Features · Capacity: 3kg~ 50kg · Excellent waterproof ability · High accuracy · Max. platform size: 250×350mm · L6D21 load cells are available in the capacities 3kg~ 50kg. · Aluminum construction with parallel beam. · Special sealing techniques and surface anodized makes waterproof and anti-corrosion. · Integral structure and easy installation. · Suitable for pricing scales, platform scales and other electronic weighing devices which has high requirements for waterproof ability. Wiring: Shielded, 4 conductor cable, and cable jacket is PVC. Cable length: 4m Cable diameter: 3.8±0.2mm Output (+) Green Input (-) Black Output (-) White Input (+) Red Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 3000 Emax/7000 ≤±0.020 ≤±0.0167 ≤±0.0175 ≤±0.020 2.0±0.2 409±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm Specifications 3/6/10/15/20/30/40/50 IP68 15(0.59) 2Places22 (0.87) 106 (4.17) 30 (1.18) 130 (5.12) 4-M6-6H Through nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) 15 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK
  • 23. 40(1.57) 150(5.91) 33(1.30) 4 Places 35(1.38) 7(0.28) 19(0.75) 8-M8-6H Depth 20(0.79) Through hole 15(0.59) 19(0.75) 19(0.75) 7(0.28) Outline Dimension mm(inch) L6E Features · Capacity: 50kg~ 300kg · High accuracy · Max. platform size: 400×400mm · OIML Certificates No:R60/2000-CN-00.04 Revision 1 · PTB Approval No:D09-03.21 Revision 1 · NTEP Certificates No: CC:11-062 Capacity Accuracy Approvals Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 OIML R60 C3 3000 Emax/7000 ≤±0.020 ≤±0.0167 ≤±0.0175 ≤±0.020 2.0±0.2 406±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm Specifications · L6E load cells are available in the capacities 50kg~ 300kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for pricing scales, platform scales and other electronic weighing devices. Wiring: hielded, 4 conductor cable, and cable jacket is PVC. Cable length: 2±0.1m Cable diameter: 5.3±0.2mm S Output (+) Green Input (-) Black Output (-) White Input (+) Red IP65 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin 8-M8-6H Depth 20(0.79) Depth 24 16 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM 50/60/80/100/150/200/300
  • 24. B6E Outline Dimension mm(inch) Wiring: Shielded, 4 conductor cable:Φ5mm Standard cable length: 2m Output (+) Green Input (-) Black Output (-) White Input (+) Red · B6E load cells are available in the capacities 100kg~ 300kg. · 17-4PH stainless steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. · Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. · Recommended platform size: 400×400mm Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction Capacity C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.2/2.0±0.002 384±4/400±20 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm 100/150/200/300 16.5(0.65) 8-M6-6H 15(0.59)Depth 35 (0.99) 15(0.59) 7(0.28) Two ends 2-3 Two ends Two ends Twoends Two ends 19(0.75) 150(5.91) 40(1.57) 38(1.50) ) 0 3 . 1 ( 3 3 8 (0.31) 38 (1.50) IP66 Specifications 2 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin Features · Capacity: 100kg~ 300kg · High accuracy · Stainless steel construction · Low profile and easy installation 17 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK
  • 25. Outline Dimension mm(inch) H6E Features · Capacity: 100kg~ 300kg · High accuracy · Alloy · steel construction Low profile and easy installation Wiring: Shielded, 4 conductor cable: Φ5mm Standard cable length: 2m Output (+) Green Input (-) Black Output (-) White Input (+) Red · H6E load cells are available in the capacities 10 ~ · Alloy nickel plated, · · × 0kg 300kg. steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. Recommended platform size: 400 400mm Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction Capacity C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.2/2.0±0.002 384±4/400±20 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm Specifications 100/150/200/300 IP66 16.5(0.65) 8-M6-6H Depth 15(0.59) 35 (0.99) 15(0.59) 7(0.28) Two ends 2-3 Two ends Twoends Two ends 19(0.75) 150(5.91) 40(1.57) 38(1.50) ) 0 3 . 1 ( 3 3 8 (0.31) 38 (1.50) 17 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin Two ends 18 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  • 26. 40(1.75) 2 Places 33(1.30) 2 Places 6(0.24) 150(5.91) 8-M6-6H Depth 20(0.79) 44(1.73) 30(1.18) 19(0.75) 2 Places 2Places Outline Dimension mm(inch) L6E3 Features · Capacity: 50kg~ 300kg · High accuracy · Max. platform size: 450×450mm · OIML Certificates No:R60/2000-CN1-06.08 · PTB Approval No: D09-06.09 · NTEP Certificates No: CC11-062 Capacity Accuracy Approvals Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction 2.0±0.2 406±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm Specifications · L6E3 load cells are available in the capacities 50kg~ 300kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic pricing scales, electronic platform scales and other electronic weighing devices. 50/100/150/200/250/300 Wiring: hielded, 4 conductor cable, and cable jacket is PVC. Cable length: 3±0.1m Cable diameter: 5.3±0.2mm S Output (+) Green Input (-) Black Output (-) White Input (+) Red IP65 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) C3 OIML R60 C3 3000 Emax/7000 ≤±0.020 ≤±0.0167 ≤±0.0175 ≤±0.020 nmax vmin Underport Depth 24(0.94) 19 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK Central Carolina Scale, Inc 5393 Farrell Road Sanford NC 27330 PH: 919-776-7737 www.CentralCarolinaScale.com
  • 27. B6E3 Features · Capacity: 20kg~ 300kg · High accuracy · Stainless steel construction · Low profile and easy installation Outline Dimension mm(inch) Wiring: Shielded, 4 conductor cable: Φ5mm Standard cable length: 3m Output (+) Green Input (-) Black Output (-) White Input (+) Red · B6E3 load cells are available in the capacities ~ · · · Max. × 20kg 300kg. 17-4PH stainless steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. platform size: 400 400mm Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction Capacity C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0 0 2/2.0±0.002 384±4 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm ± . 20/30/50/75/100/150/200/250/300 IP66 40 (1.57) Two ends 8-M8-6H Depth 20 6(0.24) 2-3 Two ends Twoends 19(0.75) Two ends 150(5.91) 15.5 (0.61) Φ12.2 Through 33(1.30) 38 (1.50) 38(1.50) 8(0.31) 44 (1.73) 30(1.18) 19 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin Underport Depth27 Specifications 20 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  • 28. L W H W1 H1 8-M L6F Features · Capacity: 50kg~ 2000kg · High accuracy · Max. platform size: 50kg~ 200kg 600×600mm 250kg~ 500kg 600×800mm 750kg~ 2000kg 1200×1200mm · OIML Certificates No:R60/2000-CN1-06.01 Revision 1 · PTB Approval No:D09-06.10 Capacity Accuracy Approvals Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 OIML R60 C3 3000 Emax/7000 ≤±0.020 ≤±0.0167 ≤±0.0175 ≤±0.020 2.0±0.2 406±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm Specifications · L6F load cells are available in the capacities 50kg~ 2000kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic pricing scales, platform scales and other electronic weighing devices. Wiring: hielded, 6 conductor cable, and cable jacket is PVC. Cable length: 3±0.1m Cable diameter: 6.2±0.2mm S 50/100/150/200/250/500/750/1000/2000 Input (+) Red Input (-) Yellow Output (-) White Output (+) Blue Shield Sense (+) Brown Sense (-) Black M12-7H Depth20(0.79) Dimension Capacity 50~200kg,250kgSE 250~500kg,750kgSE 750~2000kg H H1 L W W1 M M16-7H Depth20(0.79) M12-7H Depth18(0.71) 75(2.95) 95(3.74) 125(4.92) 50(1.97) 70(2.76) 85(3.35) 156(6.14) 146(5.75) 176(6.93) 44(1.73) 60(2.36) 76(2.99) 24(0.94) 36(1.42) 46(1.81) IP65 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin Outline Dimension mm(inch) UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 21
  • 29. 4-R3 2 2 Places 2 4 Places H2 Twoends H H1 Twoends 8-MDepth20 B1 Twoends 3 2Places L1 B L L2 B6F Features · Capacity: 100kg~ 2000kg · High accuracy · Stainless steel construction · Low profile and easy installation · OIML Certificates No:R60/2000-NL1-10.31 Outline Dimension mm(inch) Wiring: Shielded, 4 conductor cable: Φ6.2mm Standard cable length: 3m · B6F load cells are available in the capacities 100kg~ 2000kg. · 17-4PH stainless steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. · Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. · Max. platform size: 100kg~ 200kg 400×400mm 250kg~ 500kg 600×800mm 750kg~ 2000kg 1200×1200mm Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.2/2.0±0.002 384±4/400±20 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm Specifications 100/150/200/250/500/750/1000/2000 Output (+) Blue Sense (-) Black Output (-) White Input (+) Red Input (-) Yellow Sense (+) Brown Dimension 250kg~500kg 44(1.73) 24(0.94) 75(2.95) 50(1.97) 30(1.18) 156(6.14) 112(4.4) 14(0.55) M12-7H B B1 H H1 H2 L L1 L2 M 60(2.36) 36(1.42) 95(3.74) 70(2.76) 30(1.18) 146(5.75) 110(4.33) 11(0.43) M12-7H 76(2.99) 46(1.81) 125(4.92) 95(3.74) 65(2.56) 176(6.93) 110(4.33) 24(0.94) M16-7H 750kg~2t100kg~200kg Capacity IP66 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin 9 2 h t p e D 22 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  • 30. H6F Features · Capacity: 100kg~ 2000kg · High accuracy · Alloy steel construction · Low profile and easy installation Outline Dimension mm(inch) Wiring: Shielded, 4 conductor cable: Φ5mm Standard cable length: 3m · H6F load cells are available in the capacities 100kg~ 2000kg. · Alloy steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. · Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. · Max. platform size: 100kg~ 200kg 400×400mm 250kg~ 500kg 600×800mm 750kg~ 2000kg 1200×1200mm Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.2/2.0±0.002 384±4/400±20 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm Specifications 100/150/200/250/350/500/750/1000/2000 Output (+) Blue Sense (-) Black Output (-) White Input (+) Red Input (-) Yellow Sense (+) Brown Dimension 250kg~500kg 44(1.73) 24(0.94) 75(2.95) 50(1.97) 30(1.18) 156(6.14) 112(4.4) 14(0.55) M12-7H B B1 H H1 H2 L L1 L2 M 60(2.36) 36(1.42) 95(3.74) 70(2.76) 30(1.18) 146(5.75) 110(4.33) 11(0.43) M12-7H 76(2.99) 46(1.81) 125(4.92) 95(3.74) 65(2.56) 176(6.93) 110(4.33) 24(0.94) M16-7H 750kg~2t100kg~200kg Capacity IP66 4-R3 2 2 Places 5 4 Places H2 Twoends H H1 Twoends 8-MDepth20 B1 Twoends 3 2Places L1 B L L2 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin 9 2 h t p e D UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 23
  • 31. Specifications 8-M8-7H Depth 32(1.26) 4 Places 7(0.28) 4 Places 19(0.75) 65(2.56)60(2.36) 30(1.18) 42(1.69) 174(6.86) 43(1.69) Outline Dimension mm(inch) L6G Features · Capacity: 50kg~ 600kg · High accuracy · Max. platform size: 600×600mm · OIML Certificates No:R60/2000-CN-00.03 · PTB Approval No:D09-03.22 Revision 2 Capacity Accuracy Approvals Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 OIML R60 C3 3000 Emax/7000 ≤±0.020 ≤±0.0167 ≤±0.0175 ≤±0.020 2.0±0.2 406±6/1065±15 350±3/1000±10 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm · L6G load cells are available in the capacities 50kg~ 600kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic pricing scales, platform scales and other electronic weighing devices. Wiring: hielded, 6 conductor cable, and cable jacket is PVC. Cable length: 3±0.1m Cable diameter: 6±0.2mm The shield is connected to the element. S 50/100/150/200/250/300/500/600 Input (+) Red Input (-) Black Output (-) White Output (+) Green Shield Sense (+) Blue Sense (-) Yellow IP65 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin Underport Depth 40(1.57) 24 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  • 32. 63(2.48) 65(2.56) 32.5(1.28) 174(6.85) Twoends 30(1.18) 60(2.36) 16.5 (0.65) 43(1.69) Two ends Twoends 8-M8-6H Depth 25(0.98) Two ends 7(0.28) 19(0.75) 2-3 (0.12) B6G Features · Capacity: 100kg~ 600kg · High accuracy · Stainless steel construction · Low profile and easy installation Outline Dimension mm(inch) Wiring: Shielded, 6 conductor cable: Φ6.2mm Standard cable length: 3m · B6G load cells are available in the capacities 100kg~ 600kg. · 17-4PH stainless steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. · Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. · Recommended platform size: 600×600mm Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.002 384±4 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm Specifications 100/150/200/250/300/500/600 Output (+) Blue Sense (-) Black Output (-) White Input (+) Red Input (-) Yellow Sense (+) Brown IP66 kg (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin Underport Depth33(1.3) UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 25
  • 33. H6G Features · Capacity: 100kg~ 600kg · High accuracy · Alloy steel construction · Low profile and easy installation Outline Dimension mm(inch) Wiring: Shielded, 6 conductor cable: Φ6.2mm Standard cable length: 3m · H6G load cells are available in the capacities 100kg~ 600kg. · Alloy steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. · Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. · Recommended platform size: 600×600mm Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.002 384±4 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm Specifications 100/150/200/250/300/500/600 Output (+) Blue Sense (-) Black Output (-) White Input (+) Red Input (-) Yellow Sense (+) Brown IP66 632.48() 652.56() 32.5(1.28) 174(6.85) Twoends 30(1.18) 60(2.36) 16.5 (0.65) 43(1.69) Two ends Twoends 8-M8-6H Depth 25(0.98) Two ends 7(0.28) 19(0.75) 2-3 (0.12) kg (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin Underport Depth33(1.3) 26 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  • 34. H6G5 Features · Capacity: 50kg~ 2t · High accuracy · Alloy steel construction · Low profile and easy installation Outline Dimension mm(inch) Wiring: Shielded, 4 conductor cable: Φ6.2mm Standard cable length: 3m · H6G5 load cells are available in the capacities 50kg~ 2000kg. · Alloy steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. · Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. · Max. platform size: 50kg~ 1t 600×800mm 1.5t~ 2t 1000×1000mm tCapacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.002 384±4 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm Specifications Output (+) Blue Sense (-) Black Output (-) White Input (+) Red Input (-) Yellow Sense (+) Brown Dimension 1.5t~2t50kg~1t Capacity 50kg/100kg/150kg/200kg/250kg/300kg/500kg/1t/2t L H H1 W W1 68(2.68) 38(1.50) 77(3.03) 46(1.81) 76(2.99) 150(5.91)150(5.91) 88(3.46) 55(2.17) 42(1.65) IP66 16.5(0.65) 8-M14-6H Depth 25 2-3 H H1 Twoends H/2 2-W1 Twoends W L (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 27
  • 35. Outline Dimension mm(inch) L6H5 Features · Capacity: 4kg~ 20kg · High accuracy · Max. platform size: 200×200mm · OIML Certificates No:R60/2000-NL1-10.23 Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction kg Specifications 4/5/6/8/10/20 C3D 2500 Emax/5000 ≤±0.030 ≤±0.020 ≤±0.020 ≤±0.020 2.0±0.2 406±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm · L6H5 load cells are available in the capacities 4kg~ 20kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic balance and other electronic weighing devices. Wiring: Output (+) Green Input (-) Black Output (-) White Input (+) Red Shielded, 4 conductor cable, and cable jacket is PVC. Cable length: 0.17±0.05m Cable diameter: 3.8±0.2mm 2Places 28(1.18) 50(1.97) 20(0.79) 80(3.15) 4-M8Depth10(0.39) 2Places IP65 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin 28 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  • 36. Outline Dimension mm(inch) L6J Features · Capacity: 1kg~ 20kg · High accuracy · Max. platform size: 200×200mm Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction kg Specifications · L6J load cells are available in the capacities 1kg~ 20kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic balance and other electronic weighing devices. Wiring: Output (+) Green Input (-) Black Output (-) White Input (+) Red Shielded, 4 conductor cable, and cable jacket is PVC. Cable length: 0.45±0.05m Cable diameter: 3.0±0.2mm 32(1.26) 2 Places 32(1.26) 10(0.39) 2 Places 2-M5Depth18(0.71) 79(3.11) 88(3.46) 16(0.63) 2-M5 Depth 18(0.71) IP65 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin 1/2/3/5/8/10/15/20 C3D 2500 Emax/5000 ≤±0.030 ≤±0.020 ≤±0.020 ≤±0.020 1.5±0.2 406±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 29
  • 37. 4-M3 Depth 14(0.55) 70(2.76) 2Places 7(0.28) 12 (0.47) 22 (0.87) 2 Through holes 6 (0.23) Outline Dimension mm(inch) L6J1 Features · Capacity: 0.3kg~3kg · High accuracy · Max. platform size: 200×200mm Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction kg Specifications · L6J1 load cells are available in the capacities 0.3kg~3kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic balance and other electronic weighing devices. Wiring: Output (+) Green Input (-) Black Output (-) White Input (+) Red Shielded, 4 conductor cable, and cable jacket is PVC. Cable length: 0.45±0.05m Cable diameter: 3.0±0.2mm IP65 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin 0.3/0.4/0.5/0.6/1/3 C3D 2500 Emax/5000 ≤±0.030 ≤±0.020 ≤±0.030 ≤±0.030 1.0±0.1 394±6 350±3 ≥5000(50VDC) 2 -10~+40 -35~+65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm 30 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  • 38. Outline Dimension mm(inch) L6L Features · Capacity: 5kg~ 200kg · High accuracy · Max. platform size: 350×400mm Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction kg · L6L load cells are available in the capacities 5kg~ 200kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic balance and other electronic weighing devices. Wiring: Output (+) Green Input (-) Black Output (-) White Input (+) Red Shielded, 4 conductor cable, and cable jacket is PVC. Cable length: 1.0±0.05m Cable diameter: 5.3±0.2mm IP65 40(1.57) F View 2-M6 Depth 20(0.79)M6-7H Through hole 18(0.71) 6(0.24) 18(0.71) 31(1.22) 2Places 4-M6 Depth 20(0.79) 6(0.24) F View 18(0.71) 18(0.71) 150(5.91) Specifications (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin 5/8/10/15/20/30/50/80/100/150/200 C3D 2500 Emax/5000 ≤±0.030 ≤±0.020 ≤±0.021 ≤±0.028 2.0±0.2 394±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 31
  • 39. Capacity Accuracy Approvals Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction kg Specifications 3/5/8/10/15/20/30/50/75/100 C3 OIML R60 C3 3000 Emax/7000 ≤±0.020 ≤±0.0167 ≤±0.0175 ≤±0.020 2.0±0.2 406±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm Outline Dimension mm(inch) L6N Features · Capacity: 3kg~ 100kg · High accuracy · Max. Platform size: 400×400mm · OIML Certificates No:R60/2000-CN1-06.04 · PTB Approval No:D09-06.11 · NTEP Certificates No: CC11-055 · L6N load cells are available in the capacities 3kg~ 100kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic balance and other electronic weighing devices. Wiring: Output (+) Green Input (-) Black Output (-) White Input (+) Red Shielded, 4 conductor cable, and cable jacket is PVC. Cable length: 3.0±0.05m Cable diameter: 5.0±0.2mm Ip65 7-M Depth 15(0.59) 19(0.75) 2Places 31.24 (1.23) 11.18 (0.44) 40 (1.58) 19 (0.75) 150(5.9) 5.84(0.23) 2Places 25.4 (1.0) 100(3.94) 34 (1.34) (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin 32 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  • 40. B6N Features · Capacity: 15kg~ 200kg · High accuracy · Stainless steel construction · Low profile and easy installation · OIML Certificates No:R60/2000-NL1-11.27 Outline Dimension mm(inch) Wiring: hielded, 4 conductor cable: Φ5mm Standard cable length: 1m S · B6N load cells are available in the capacities 15kg~ 200kg. · 17-4PH stainless steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. · Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. · Recommended platform size: 400×400mm Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.002 384±4 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm Specifications Output (+) White Sense (-) Yellow Output (-) Red Input (+) Green Input (-) Black Sense (+) Blue 15/20/30/50/75/100/150/200 Note: Machining thread hole M and N are basing on customers' requirements. When customers require imperial: Thread hole M is 1/4-20UNC-2B, Thread hole N is 1/4-28UNF-2B; When customers require metric: Both thread holes M and N are M6-6H, and there will be an "M" under exit hole. · · · IP66 34 Twoends(1.34) 19.05 (0.75) 25 (0.98) 38(1.5) 19.05(0.75) 150(5.91) H1 4-MDepth15(0.59) H 40(1.57) 38(1.496) NDepth15(0.59) 100(3.94) kg (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin Underport Depth18(0.71) Underport Depth18(0.71) UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 33
  • 41. Outline Dimension mm(inch) L6Q Features · Capacity: 50kg~ 250kg · High accuracy · Max. platform size: 400×400mm PTB Approval No: D09-07.06· · NTEP Certificates No: CC11-104 Capacity Accuracy Approvals Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 OIML R60 C3 3000 Emax/7000 ≤±0.020 ≤±0.0167 ≤±0.0175 ≤±0.020 2.0±0.2 406±6 350±3 ≥5000(50VDC) 2 10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm - kg Specifications · L6Q load cells are available in the capacities 50kg~ 250kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, stainless steel cover, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic pricing scales, platform scales and other electronic weighing devices. Wiring: Shielded, 6 conductor cable, and cable jacket is PVC. Cable length: 3.0±0.05m Cable diameter: 5.0±0.2mm 50/100/150/200/250 Input (+) Red Input (-) Black Output (-) White Output (+) Green Sense (+) Blue Sense (-) Brown M Metric Imperial M6 1/4-20UNC 8-M Depth 13(0.51) 6.35(0.25) 2 Places 25.1(1.0) 2 Places 150(5.91) 25.4(1.0) 44(1.73) 38.1(1.5) 2Places 38.1(1.5) IP66 nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) Depth15(0.59) 34 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  • 42. B6Q Features · Capacity: 200kg and 250kg. · High accuracy · Stainless steel construction · Low profile and easy installation Outline Dimension mm(inch) Wiring: Shielded, 6 conductor cable: Φ5.0mm Standard cable length: 1.5m · B6Q load cells are available in the capacities 200kg and 250kg. · 17-4PH stainless steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. · Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. · Recommended platform size:400×400mm kgCapacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.2/2.0±0.002 384±4/400±20 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm Specifications Output (+) White Sense (-) Yellow Output (-) Red Input (+) Green Input (-) Black Sense (+) Blue 200/250 IP66 38.1 Twoends(1.5) 38 (1.5) 9.35 (0.37) 38 (1.5) 39.9 (1.57) 8-1/4-20UNF-2BDepth15(0.59) 38.1(1.5) 6.35 (0.25) 25.4 4Places(1.0) 150(5.91) 8(0.31) 4-25.4(1.0) Twoends 1/4-28UNF-2B Depth10 41.5(1.63) nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) Underport Depth12 Underport Depth18(0.71) 35 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 35
  • 43. L6T Features · Capacity: 50kg~ 1000kg · High accuracy · Max. platform size: 600×600mm · OIML Certificates No:R60/2000-DE1-10.11 Capacity Accuracy Approvals Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 OIML R60 C3 3000 Emax/7000 ≤±0.020 ≤±0.0167 ≤±0.0175 ≤±0.020 2.0±0.2 406±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm kg Specifications · L6T load cells are available in the capacities 50kg~ 1000kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic pricing scales, electronic platform scales and other electronic weighing devices. Wiring: Shielded, 6 conductor cable, and cable jacket is PVC. Cable length: 3.0±0.1m Cable diameter: 5.0±0.2mm 50/75/100/150/200/250/300/500/635/1000 Input (+) Red Input (-) Black Output (-) White Output (+) Green Sense (+) Blue Sense (-) Brown M Metric Imperial M8x1.25 5/16-18UNC-2B 76.2(3.0) 39.8 (1.57) 2Places 24.9(0.98)8-D Depth16(0.63) 60.2(2.37) 2Places 2Places 39.8 (1.57) 7.87(0.31) 2Places 191(7.52) 75.44(2.97) IP65 nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) Outline Dimension mm(inch) 36 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  • 44. Outline Dimension mm(inch) L6W Features · Capacity: 50kg~ 635kg · High accuracy · Recommended platform size: 50kg~ 200kg: 600×600mm 250kg~ 635kg:600×800mm · OIML Certificates No:R60/2000-CNI-06.03 · PTB Approval No: D09-06.12 Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 3000 Emax/7000 ≤±0.020 ≤±0.0167 ≤±0.0175 ≤±0.020 2.0±0.2 406±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm Specifications · L6W load cells are available in the capacities 50kg~ 635kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic balance and other electronic weighing devices. Wiring: Shielded, 4 conductor cable, and cable jacket is PVC. Cable length: 3.0±0.1m Cable diameter: 4.7±0.2mm 50/100/150/200/250/300/500/635 Input (+) Red Input (-) Black Output (-) White Output (+) Green Sense (+) Blue Sense (-) Brown 2Places 55(2.17)2Places 2Places 188(7.40) 5.5(0.22) 35(1.38) 2Places 50(1.97) 2Places 8-M8(0.31)-6M Depth 20(0.79) 63.5(2.51) IP65 62.3(2.45) kg Approvals OIML R60 C3 nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) 37 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 37
  • 45. BM6A Features · Capacity: 6kg~ 60kg · High accuracy · Stainless steel construction · Low profile and easy installation · OIML Certificate No: R60/2000-NL1-10.32 Outline Dimension mm(inch) Wiring: Cable diameter: Φ5±0.2mm Standard length for 6 conductor cable: 6m · BM6A load cells are available in the capacities 6kg~ 60kg, and 25~ 100lb. · 17-4PH stainless steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. · Single point with parallel beam, suitable for electronic scales, platform scales, belt scales, packaging scales and other electronic weighing devices. · Recommended platform size: 300×300mm Dimension Capacity 6,12,15,30kg 60kg L H W 130(5.12) 130(5.12) 50(1.96) 50(1.96) 18.5(0.73) 23.5(0.92) 6,12,15,30,60kg 50 (1.97) 10-M6 Depth 8(0.32) W 25 (0.98) 42.5(1.67) 19(0.75) L (0.95) 24 19 (0.75) 65(2.56) 157(6.18) 6 (0.24)24 (0.95) Output (+) White Sense (-) Blue Output (-) Red Input (+) Green Input (-) Black Sense (+) Yellow Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction kgCapacity C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.2/2.0±0.002/3.0±0.2 400±20 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 Specifications Note: output sensitivity of S1 type is 2.0±0.002mv/v; output of imperial model is 3.0±0.2mv/v, 0.02% /100mmload value 6/12/30/60 nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) 38 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  • 46. BM6E Features · Capacity: 3kg~ 300kg · High accuracy · Stainless steel construction · Low profile and easy installation Outline Dimension mm(inch) Wiring: Shielded, 4 conductor cable: Φ5mm Standard cable length: 2m Output (+) Green Input (-) Black Output (-) White Input (+) Red · BM6E load cells are available in the capacities 50kg~ 300kg. · Stainless steel construction, hermetically welded oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. · Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. · Recommended platform size: 600×600mm Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction Capacity C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.2/2.0±0.002 350±3.5 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 Specifications 3/50/100/200/300 0.02% /100mmload value 150(5.9) 15 (0.59) 40(1.57) 35(1.38) 8-M6-6H Depth 15(0.59)7(0.28) 2 Places 15(0.59) 2Places 19(0.75) 2 Places kg nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) Depth 17(0.67) 37 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 39
  • 47. BM6G Features · Capacity: 75kg~ 500kg · High accuracy · Stainless steel construction · Low profile and easy installation · PTB Approval NO:D09-10.06 · OIML Certificates NO:R60/2000-NL1-11.29 · NTEP Certificate No: CC12-017 · BM6G load cells are available in the capacities 75kg~ 500kg. · 17-4PH stainless steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. · Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. · Safe and anti-explosive product, can be used in atrocious environment and hazardous areas. · Recommended platform size: 800×800mm Outline Dimension mm(inch) Wiring: Shielded, 4 conductor cable:Φ5mm Standard cable length: 3m Output (+) Green Input (-) Black Output (-) White Input (+) Red 43(1.69) 2 Places 62 (2.44) 19(0.75) 2 Places7 (0.28) 18 (0.71) 174(6.85) 45(1.77) 30(1.81) 2Places 8-M8 Depth18(0.71) 62(2.44) 64(2.52) 32(1.26) Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.2/2.0±0.002 350±3.5 350±3.5 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm Specifications 3/75/100/150/200/300/400/500kg nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) OIML R60 C3Approvals Depth 22(0.87) 40 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  • 48. Features · Capacity: 500kg~ 50t · High accuracy · Alloy steel construction · Low profile · OIML Certificate No: R60/2000-NL1-12.14 Accessories · HY-8-101 · HM-8-401 · HM-8-406 · Hm8 load cells are available in the capacities 500kg~ 50t. · Alloy steel, hermetically welded, oil-proof, waterproof and anti-corrosion, suitable for all kinds of environments. · Single shear beam, easy for installation, suitable for electronic truck scales, track scales, hopper scale and other electronic weighing devices. · Safe and anti-explosive product, can be used in atrocious environment and hazardous areas. HM8 Outline Dimension mm(inch) 37 (1.47) 57.9 (2.28) 37 (1.47) 57.9 (2.28) 37 (1.47) 62.9 (2.48) Capacity Dimension 35 (1.38) 48 (1.89) 78.7 (3.1) 60 (2.36) 127.7 (5.03) 35 (1.38) 35 (1.38) 42 (1.65) 57 (2.24) 1-2t 2.5t 3t 5t 5 (0.2) 5 (0.2) 5 (0.2) 8 (0.31) 12 (0.47) 43 (1.69) 43 (1.69) 43 (1.69) 52 (2.05) 67 (2.64) 37 (1.47) 37 (1.47) 15 (0.59) 48 (1.89) 60 (2.36) 37 (1.47) 13 (0.51) 15 (0.59) 21 (0.83) 28 (1.10) 203 (7.99) 203 (7.99) 203 (7.997) 235 (9.25) 279 (10.98) 95 (3.74) 95 (3.74) 95 (3.74) 110 (4.33) 133 (5.24) 22 (0.87) 22 (0.87) 22 (0.87) 22 (0.87) 32 (1.26) 98 (3.86) 98 (3.86) 98 (3.86) 124 (4.88) 140 (5.51) 82.5 (3.25) 115 (4.53) 90 (3.54) 70 (2.76) 12 (0.47) 18 (0.71) 143.5 (5.65) 174 (6.85) 70 (2.76) 70 (2.76) 34 (1.34) 26 (1.02) 70 (2.76) 96 (3.78) 318 (12.52) 374 (14.72) 153 (6.02) 189 (7.44) 38 (1.5) 44.5 (1..75) 159 (6.26) 181 (7.13) 64 (2.52) 64 (2.52) 64 (2.52) 66 (2.6) 82 (3.32) 89 (3.5) 76 (2.99) / / / / / / 51 (2.01) / / / / / / 46 (1.81) Wiring: Shielded, 6 conductor cable:Φ6.2mm Standard cable length: 6m Output (+) Blue Sense (-) Black Output (-) White Input (+) Red Input (-) Yellow Sense (+) Brown 10t,15t 20t,25t 30t H H1 H2 H3 ΦD ΦdW L L1 L2 L3 L4 L5 L6 L H2 H1 L1 H3 2-Φd 30t,50tThrough hole Through hole 0.5t,25t L4 L3 L2 L6 WW H L5 L3 L2L4 ΦD 6-Φd tCapacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 Specifications 500kg/1/2/2.5/3/5/10/15/20/25/30/50 2.0±0.002 350±3.5 352±3.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) 37 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 41