SlideShare une entreprise Scribd logo
1  sur  101
Télécharger pour lire hors ligne
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 1 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
HANDBOOKHANDBOOKHANDBOOKHANDBOOK
ForForForFor
Outside PlantOutside PlantOutside PlantOutside Plant----Fiber to the HomeFiber to the HomeFiber to the HomeFiber to the Home
(FTTH(FTTH(FTTH(FTTH----OSP)OSP)OSP)OSP)
ForForForFor
PT TELKOM INDONESIAPT TELKOM INDONESIAPT TELKOM INDONESIAPT TELKOM INDONESIA
V 1.0V 1.0V 1.0V 1.0
<REFERENCE<REFERENCE<REFERENCE<REFERENCE ffffor DESIGN,or DESIGN,or DESIGN,or DESIGN,
WORKWORKWORKWORK IMPLEMENTATION & TESTING>IMPLEMENTATION & TESTING>IMPLEMENTATION & TESTING>IMPLEMENTATION & TESTING>
(June 2013)(June 2013)(June 2013)(June 2013)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 2 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
Contents
PART-I DESIGN & INSTALLATION ........................................................................ 4
FTTH-OSP DESIGN PRINCIPLES .......................................................................... 5
MATERIALS FOR FTTH-OSP (STO - ODP) .......................................................................... 7
MATERIALS FOR FTTH-OSP (HRB: Hign-Rise Building) ......................................................... 8
1. FEEDER CABLE DESIGN .. . ... 11
1.1 Google Map .......................................... 11
1.2 Skema Kabel Feeder .. ............... . 12
1.3 PetaLokasi Duct & Kabel Feeder . .. . 15
1.4 Sample Design of Feeder Cable Network . . ............. 15
1.5 Core Assignment Diagram . . . .. 19
1.6 General Concept for Feeder Cable Design . .. ............ 22
2. DISTRIBUTION CABLE DESIGN . 25
2.1 Google Map .. ... 25
2.2 Skema Kabel Distribusi .. 25
2.3 Sample Design of Distribution Cable Network . ............ 28
2.4 Branching ODP .. .......... 32
2.5 Duct Usage for Distribution Network & Drop-core Installation (Underground) .......................... 33
3. GENERAL CONCEPT FOR DISTRIBUTION CABLE DESIGN ............. 34
3.1 Duct / Buried Section . ............... 34
3.2 Aerial Section .. ............................ 37
4. CABLE RACK / OTB RACK IN STO BUILDING .. . 41
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 3 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
5. HIGH-RISE BUILDING (HRB) DESIGN ......................................................................... 42
5.1 Materials for HRB Solution ........................................... 42
5.2 Design Concept for HRB Solution .. ............... .. 43
5.3 Type of ODC for High-Rise-Building . .. .. 44
5.4 Example of Cable Tray/Trunking . . ............. 45
5.5 Sample Design: Skema Distribusi . . . .. 46
5.6 Sample Design: Peta Lokasi Distribusi . .. ............ 47
6. REFERENCE . 50
6.1 Pondasi ODC-C-144 Splitter .. ... 51
6.2 Pondasi ODC-C-288 Splitter .. ... 52
6.3 Pondasi ODP Pedestal & HH-PIT-60 . .............. 53
6.4 HH-1: Dimensi Dalam (P=1700 x L=1250 x T=1300) ... .. .......... 54
6.5 HH-2: Dimensi Dalam (P=1200 x L=600 x T=1300) .............................................................. 55
6.6 HH-80: Dimensi Dalam (P=800 x L=800 x T=800) .............................................................. 56
6.7 Installation of ODP Wall ............................................................................ 57
6.8 Form for Core Assignment Diagram ............................................................................ 59
6.9 Installation Check Sheet ............................................................................ 63
6.10 List of Assembly Unit Designator ............................................................................ 67
PART-II ACCEPTANCE TESTING ........................................................................ 73
1. TEST PROCEDURE ................................ 74
2. OPM MEASUREMENT ......................................................................... 86
2.1 Application of Measurement Forms . ............... 87
2.2 Measurement Forms .. ............................ 92
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 4 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 5 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
FTTH-OSP DESIGN PRINCIPLES (1)
1. FTTH OSP Design Work (Feeder & Distribusion) shall be carried out in accordance
with the frame of this document.
2. LINK BUDGET
1) Descriptions in the Contract:
The Design shall ensure the FTTH OSP System Power Budget of the GPON OLT
to ONU (in the configuration of 1:4 Splitter at ODC and 1:8 Splitter at ODP) shall
be 28dB (including the margin of 3dB).
2) Applicable Power Budget in the Project:
Contract Requirement: 28dB - 3dB (Margin) = 25dB (ITU-T G.652D @ Wave
Length 1310nm=0.35dB/km)
Requirement by KBB: 25dB - 2dB = 23dB (including 2dB as an Additional
Margin due to an incidental increment of the loss in OSP during an operation)
Link Budget to be applied for the Project: 25dB @ 1310nm
We may try however, to keep 23dB @ 1310nm as far as practicable.
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 6 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
FTTH-OSP DESIGN PRINCIPLES (2)
3. FTTH OSP Design shall be composed of the following:
3.1 Feeder Cable Design
1) Google Map per STO
2) Skema Kabel Feeder (Schematic Drawing)
3) Skema Duct (Schematic Drawing)
4) Peta Lokasi Duct & Kabel Feeder (Location Map)
5) Special Design (MH Modification, Duct Bridge etc.)
3.2 Distribution Cable Design
1) Google Map per Lokasi
2) Skema Kabel Distibusi
3) Peta Lokasi Distribusi
4) Special Design (HH Modification, Modified ODP Foundation etc.)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 7 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
Feeder Cable
DC-OF-SM-
12D/24D/48D/
96D/144D/288D
ODC
ODC-C-48/144/288 Splitter
Note: ODC-C-48 = Wallmount Type
Pass through closure Type/Designator
for 48core Star/Ring SC-OF-SM-PT-48
for 96core Star/Ring, 144core Star SC-OF-SM-PT-144S
for 144core Ring SC-OF-SM-PT-144R
for 288core Star SC-OF-SM-PT-288S
for 288core Ring SC-OF-SM-PT-288R
Inline closure Type/Designator
for 12c-24c SC-OF-SM-24
for 12c-48c SC-OF-SM-48
for 12c-96c SC-OF-SM-96
for 12c-144c SC-OF-SM-144
for 12c-288c SC-OF-SM-288
STO
ODC
ODP (Aerial)
ODP-SSW-8
(1:8 Splitter built-in)
Branching ODP
(Pole/Wall Mount)
ODP-PW-BR
Branching ODP
(Pedestal)
ODP-PL-BR
ODP (Wall Mount)
ODP-PW-8/16
Distribution Cable
(Aerial)
AC-OF-SM-8/12/24-SC
ODP (Pedestal)
ODPPL-8/16
Distribution Cable
(Duct)
DC-OF-SM-8/12/24-SC
Passive Splitter
PS-1-2-ODC/
PS-1-4-ODC
PS-1-8-ODP
Line Guard/
Suspension
C-Clamp
Materials for FTTH OSP (STO - ODP)
OTB
TC-OF-SM-
12/24/48/72/96/144
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 8 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
Cable Trunking and Accessories
Splitter for ODC-HRB
PS-1-4-ODC-HRB
Materials for FTTH-OSP (HRB: High-Rise Building)
ODC-HRB (Cabinet)
ODC-HRB-420
ODC-HRB-240
ODC-HRB-180
ODC-HRB(Rack)
ODC-HRB-RACK-480
ODC-HRB-RACK-240
ODC-HRB-RACK-120
19 inch Rack
TC-OF-R-19
or
Indoor Cable
(1-C Low Friction)
IC-OF-SM-1D
ODC-HRB
ODP-HRB
ODP-HRB-16/32 PS-1-8-ODP-HRB
Indoor Cable
(2-C Low Friction)
IC-OF-SM-2D
ROSETTE
RS-IN-SC-1P/
TC-MK-SC-1P
FUSE-CONNECT
ISC-UPC-FD
T-JointCable Trunking Elbow (Flat Angle)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 9 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
LIST OF MATERIALS AND INSTALLATION MANUALS (1/2) As of: 01-June-2013
No. Spec.No. Manual.No. Sub manuals
1 - 5. ESMDDLT000*****K
6 ESMDDLT00028824K
7 - 8. JBT-05166A
9 - 12. ESMDALT0000****K
13-16 ENZDSCDLT0*****K
17 - 20 ENZDSCALT00****K
21-23 ESMDDLT0000****K
24 JBT-05027B
25 - 26 JBT-05026-> JBT-05391
49 - 50 JBT-04109A
51 - 52 JBT-04770D
53 - 54 JBT-04109A
55 - 56 PNJHC-1101-54-02(2.8mm)
57 - 75 TS1211-01
76 - 78 PNJBC-0516-54-03 PNJBC-0516-82-01 ODC-C sub manual_130214
79 PNJBC-0516-54-04 PNJBC-0516-82-01 ODC-C sub manual_130214
80-81 PNJCS-0013-54-10
82 - 83 PNJCY-0085-54-03 PNJCY-0085-82-01 ODP-CA sub manual_130323
84 - 87 PNJBC-0516-54-06
88 - 89 JEMBO Pedestal + ODP-CA PNJCY-0085-82-01
90 - 95 PNJBC-0516-54-07 PNJBC-0516-82-04 TC-SM sub manual_130225
96 PNJBC-0470-54-04 PNJBC-0470-82-02
97 PNJBC-0472-54-08A
98 PNJBC-0516-54-08
99-101 PNJBC-0516-54-09 PNJBC-0516-82-06
102 - 106 PNJBC-0516-54-10
107 - 111 PNJSC-1077-54-03Rev.1
112 - 116 PNJBC-0516-54-11
117 - 121 PNJSC-1077-54-04Rev.1
200 PNJCY-0084-54-02
201 PNJCY-0084-54-01
202 PNJCY-0084-54-04
203 PNJCY-0084-54-03
204 PNJCY-0084-54-05
Manuals will be available upon supply of the material
Manauals not applicable
DC-OF-SM-*D (SM.D D - LT */*T)
DC-OF-SM-*-SC (SM.D D - LT */*T)
AC-OF-SM-8-SC (OGGDE-SSW)
Name File
AC-OF-SM-*D (SM.D A - LT */*T)
DC-OF-SM-*C (NZDS.C D - LT */*T)
AC-OF-SM-*C (NZDS.C A - LT */*T)
DC-OF-SM-288D (SM.D D - LT 288/24T)
DC-OF-SM-*D (OG8ETSWBE)
AC-OF-SM-*-SC (OGNM4WTGDE-SSW)
GC-OF-SM-1D (FR-OGINE)
HC-OF-SM-*D (FR-OGNMGDE-SSD)
GC-OF-SM-1D (FR-OGINE)
Patch cord (2.8mm, BIS-B)
Pigtails and Patchcords
ODC-C-* Splitter
ODC-C-48 Splitter
ODC-CU (FSCO-HHS)
ODP-CA-* for Pole Mount
ODP-A-*
ODP-PL-* (Pedestal_Box+ ODP-CA-* For_Wall_mount)
TC-SM-*
RS-IN-SC-1P (FPB-103A(S))
RS-IN-SC-2P (FPB-302-2SC(PT))
House Hook
Cable cleat
RS-IN-SC-4P (RS-IN-SC-4)
TC-MK-SC-*
PS-1-*-ODC (Optical Spitter Module 1 x N Type)
PS-1-*-ODP(PLC Type 1xN Splitter)
PS-2-*-ODC (Optical Spitter Module 2 x N Type)
PS-2-*-ODP (PLC Type 2xN Splitter)
Deadending Wire Vice (C clamp)
Drop Cable Clamp (S Clamp)
Selft-Support Wire Line Guard (Line Guard 2.6mm)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 10 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
LIST OF MATERIALS AND INSTALLATION MANUALS 2/2) As of: 01-June-2013
No. Spec.No. Manual.No. Sub manuals
205 PNJCY-0084-54-06
206 PNJCY-0084-54-07
207 PNJCY-0084-54-08
400 - 401 PNJHC-1101-53-01
402 PNJCY-0067-54-18 PNJC-0067-82-04
403 PNJHY-0001-53-11
404 PNJHY-0001-53-10
405 PNJHY-0107-53-05
406 PNJHY-0107-54-21Rev.2 JDAA-11-12-0048D
PNJHY-0107-54-21Rev.2 JDAA-11-13-0075
407 PNJBC-0480-54-17
408 PNJBC-0480-54-17
409 PNJBC-0480-54-17
410 B-12F0401 PNJCY-0085-82-03
411 B-12F0401 PNJCY-0085-82-03
412 PNJBC-0085-54-02 PNJCY-0085-82-01
413 PNJBC-0085-54-02 PNJCY-0085-82-01
414 JBT-04260B
415 JBT-04260B
416
417
418
419
420
421 PNJBC-0516-54-12 PNJBC-0516-82-09A
422 PNJBC-0516-54-12 PNJBC-0516-82-09A
423 PNJBC-0516-54-12 PNJBC-0516-82-09A
424 PNJBC-0516-54-13 PNJBC-0516-82-10
425 PNJBC-0516-54-13 PNJBC-0516-82-11
426 PNJBC-0527-54-07
427 PNJBC-1077-54-03Rev.1
Manuals will be available upon supply of the material
PS-1-8-ODP-HRB
ODP-HRB-16
PS-1-4-ODC-HRB
Pass through closureType4 ( For 288core Ring)
ODC-HRB-420
ODC-HRB-240
ODC-HRB-180
ODP-HRB-32
Low Friction Indoor Cable , 2C
Pass through closureType1 ( For 48core Star/Ring )
Pass through closureType2 ( For 96core Star/Ring )
Pass through closureType3 ( For 144core Ring )
Pass through closureType4 ( For 288core Star)
ODP-BR for Branching (3 Hole Type) , Pole mounting type
ODP-BR for Branching (3 Hole Type) , termasuk Dome Pedestal
ODP Outdoor/Wall , Termasuk Adaptor , Space Passive Splitter, 8 Port
ODP Outdoor/Wall , Termasuk Adaptor , Space Passive Splitter, 16 Port
Low Friction Indoor Cable , 1C
Outdoor Optical Connector Cabinet (FPB-203-*SC-A (PT)) 4 Port
L-clamp
Flex Band IBT-206
BW-Clamp
Free Bending Optical cord (3mm, BIS-B)
Outdoor Optical Connector Cabinet (FPB-203-*SC-A (PT)) 1 Port
Outdoor Optical Connector Cabinet (FPB-203-*SC-A (PT)) 2 Port
ODP-SSW (FSCO-AS-SP(in/splice))
FIELD INSTALLBLE SC CONNECTOR (FAST-SC-SM-09/CO)
FIELD INSTALLBLE SC CONNECTOR (FAST (N) -SC-SM-UNI/GT)
FUSION CONNECTOR (Fuseconnect-SC-SF-SM-20/30)
FUSION CONNECTOR (Fuseconnect-SC-DC) for Drop cable
FUSION CONNECTOR (Fuseconnect-SC-LF) for LowFriction cable
Name File
Manauals not applicable
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 11 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
1. FEEDER CABLE DESIGN
A. The Feeder Cable Route shall be planned to utilize the existing duct route as
the first priority so as to minimize the road excavation length.
B. The capacity of Feeder Cables designed/implemented by the previous
TOS/PO as well as for the followings shall be taken into account at the
Feeder Cable Capacity Planning:
1) AL PRO: Existing Facility such as MSAN, RK, etc.
2) Node B Project
3) GDI: Government Digitalization Network
1.1 GOOGLE MAP
1) Nama STO: legend berbentuk Rumah (Warna Merah)
2) Route Feeder: warna Merah
3) Nama ODC sesuai dengan Lokasi/Cluster
4) Kapasitas ODC/ Jumlah Homepass
5) Boundary ODC/Lokasi/Cluster dg Boundary Area Potensi
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 12 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
1.2 SKEMA KABEL FEEDER
► Purpose: Information required for the Feeder Cable Work
A. OTB at STO
OTB to be installed with the symbol Telkom Standard and indicated with the designator in BoQ:
Example: TC-OF-SM-xx (yy)
B. Feeder Cable
Indication: Black Line (New: 0.6 point, Existing: 0.3 point)
Information:
1) Type (Duct/Aerial) and capacity of cable
2) Length of cable
3) Core Assignment
Note: The younger core number shall be assigned for the far end (the last position) and
spare cores (Cadangan).
Total Quantity of OTB
Type of OTB
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 13 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
IDENTIFICATION OF FEEDER CABLE
FE XXX 01-01-01 (01-288)
Core No. In Cable
Segment No.
Feeder No.
Code STO
Code Feeder Cable
DC-OF-SM-XXX-xxxxM
Cable Length
in meter
No. Of Cores
Type of Cable
Duct Cable: DC-OF-SM
Aerial Cable: AC-OF-SM
Branch-Segment No.
Note:
Cable Line:
New: Tebal (e.g. 6pt.)
Existing: Tipis (e.g. 3pt.)
Identification:
New: Bold Font
Existiong: Normal Font
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 14 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
C. ODC
D. MH/HH/CLOSURE
1) MH/HH: Name of Existing MH/HH or Type of New MH/HH
2) Closure:
a. Straight Joint: SC-OF-SM-xxx
b. Pass-through Joint: SC-OF-SM-xxx-PT
ODC Capacity
ODC No. “FA”, “FB”, .......
Code STO
Code ODC
xx PS 1:4 (xxx HP)
Number of Homepass
Code Splitter 1:4
Number of Splitter 1:4
Coordinates Lokasi ODC
ODC-XXX-FA-288
( - )
Assigned core to be
terminated
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 15 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
1.4 SAMPLE DESIGN OF FEEDER CABLE NETWORK
1.3 PETA LOKASI DUCT & KABEL FEEDER
►►►► Purpose: Information required for the Civil Work shall be plot on the scaled map
1) SKEMA DUCT
(Refer to 1.4.1)
2) SKEMA KABEL FEEDER
(Refer to 1.4.2)
3) PETA LOKASI
KABEL FEEDER
(Refer to 1.4.3)
Lokasi CC
ODC-ABC-F -288
STO
ABC
24
15.0
ABC
01/01
ABC
01/02
ABC
01/03
ABC
01/xx
ABC
01/yy
6 6
664
ABC
02/02
ABC
02/01
ABC
02/xx
100.0 100.0
100.0100.0100.0
HH-2
HH-
80
DD-BM-HDPE-1
35.0
HH-1
HH-1
DD-BM-HDPE-1
150.0
DD-BM-HDPE-BIG-1DD-BM-
HDPE-
BIG-1
150.0
bbb.
0
Lokasi AA
ODC-ABC-F -144
Lokasi BB
ODC-ABC-F -288
Lokasi DD
ODC-ABC-F -144
JL.ABCRAYA
JL.ABCII
JL.ABC I
aaa.0
DD-BM-
HDPE-
BIG-1
HH-1
Cableslack(10)shallbeprovidedat
every1000mofcablelength.(Incase
ofDD-BM-HDPE,HH-1/2shallbe
installed.)
Legend:
: Assigned Duct for New Cable
: Vacant Duct
: Occupied Duct
Lokasi CC
ODC-ABC-F -288
xx PS 1:4 (yyHP)
(241-288)
NNNN xxxxxxxxxxxx°°°°xxx.xxxx
E yyy °°°° yyy.yyyy
Lokasi DD
ODC-ABC-F -144
xx PS 1:4 (yyHP)
(217-240)
NNNN xxxxxxxxxxxx°°°°xxx.xxxx
E yyy °°°° yyy.yyyy
Lokasi AA
ODC-ABC-F -144
xx PS 1:4 (yyHP)
(121-144)
NNNN xxxxxxxxxxxx°°°°xxx.xxxx
E yyy °°°° yyy.yyyy
Lokasi BB
ODC-ABC-F -288
xx PS 1:4 (yyHP)
(73-120)
NNNN xxxxxxxxxxxx°°°°xxx.xxxx
E yyy °°°° yyy.yyyy
STO ABC
TC-SM-144 (3)
FE-ABC-01-01 (01-144)
DC-OF-SM-144D m
FE-ABC-01-01-01 (121-144)
DC-OF-SM-24D m
FE-ABC-01-02(01-120)
DC-OF-SM-144D
m
FE-ABC-01-02-01 (73-120)
DC-OF-SM-48D m
CAD
(01 – 72)
FE-ABC-02-01(01-288)
DC-OF-SM-288D
m
DC-OF-SM-288D
m
FE-ABC-02-
02
(01-240)
CAD
(01 – 216)
FE-ABC-02-01-01 (241-288)
DC-OF-SM-48D m
FE-ABC-02-02-01 (217-240)
DC-OF-SM-48D m
JL.ABCRAYA
JL.ABC I
JL.ABCII
ABC
01/02
ABC
01/yy
DC-OF-SM-288D
m
FE-ABC-02-
02
(01-240)
Cable Slack (10m) shall be
placed every 1000m of
cable span and/or the
location where the future
demand is expected.
STO
ABC
100.0
ABC
01/01
DD-BM-HDPE-1
150.0
DD-BM-HDPE-1
35.0
HH-
80
HH-2
HH-1
HH-1
DD-BM-HDPE-BIG-1
150.0
JL.ABCRAYA
JL.ABCII
JL.ABC I
Lokasi BB
ODC-ABC-F -288
Lokasi AA
ODC-ABC-F -144
Lokasi CC
ODC-ABC-F -288
Lokasi DD
ODC-ABC-F -144
DD-BM-1
10.0
DD-BM-1
10.0
DD-ROD-1
15.0
DD-ROD-1
xxxx.0
ABC
01/02
ABC
01/03
ABC
01/xx
DD-BM-HDPE-
BIG-1
bbb.
0
aaa.
0
DD-BM-HDPE-
BIG-1
HH-1
ABC
02/03
ABC
02/01
ABC
02/xx
ABC
01/xx
ABC
01/xx
ABC
01/yy
ABC
02/02
DD-ROD-
1
100000000.0
DD-ROD-
1
100000000.0
DD-ROD-
1
100000000.0
DD-ROD-
1
xxx.0
DD-ROD-
1
100000000.0
DD-ROD-
1
100000000.0
DD-ROD-
1
xxx.0
DD-ROD-
1
100000000.0
DD-ROD-
1
100000000.0
DD-ROD-
1
xxx.0
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 16 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
1.4.1 SKEMA DUCT
STO ABC
24
15.0
ABC
01/01
ABC
01/02
ABC
01/03
ABC
01/xx
ABC
01/yy
66
664
ABC
02/02
ABC
02/01
ABC
02/xx
100.0100.0
100.0100.0100.0
HH-2HH-80
DD-BM-HDPE-1
35.0
HH-1HH-1
DD-BM-HDPE-1
150.0
DD-BM-HDPE-
BIG-1
DD-BM-HDPE-
BIG-1
150.0bbb.0
Lokasi AA
ODC-ABC-F -144
Lokasi BB
ODC-ABC-F -288
Lokasi CC
ODC-ABC-F -288
Lokasi DD
ODC-ABC-F -144
JL.ABC RAYA
JL.ABC II
JL.ABCI
aaa.0
DD-BM-HDPE-
BIG-1
HH-1
Cable slack (10) shall be provided at every 1000m
of cable length. (In case of DD-BM-HDPE, HH-1/2
according to Page 23, 1.6.3 shall be installed.)
Legend:
: Assigned Duct for New Cable
: Vacant Duct
: Occupied Duct
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 17 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
1.4.2 SKEMA KABEL FEEDER
Lokasi CC
ODC-ABC-F -288
xx PS 1:4 (yyHP)
(241-288)
NNNN xxxxxxxxxxxx°°°°xxx.xxxx
E yyy °°°° yyy.yyyy
Lokasi DD
ODC-ABC-F -144
xx PS 1:4 (yyHP)
(217-240)
NNNN xxxxxxxxxxxx°°°°xxx.xxxx
E yyy °°°° yyy.yyyy
Lokasi AA
ODC-ABC-F -144
xx PS 1:4 (yyHP)
(121-144)
NNNN xxxxxxxxxxxx°°°°xxx.xxxx
E yyy °°°° yyy.yyyy
Lokasi BB
ODC-ABC-F -288
xx PS 1:4 (yyHP)
(73-120)
NNNN xxxxxxxxxxxx°°°°xxx.xxxx
E yyy °°°° yyy.yyyy
STO ABC
TC-SM-144 (3)
FE-ABC-01-01 (01-144)
DC-OF-SM-144D m
FE-ABC-01-01-01 (121-144)
DC-OF-SM-24D m
FE-ABC-01-02 (01-120)
DC-OF-SM-144D m
FE-ABC-01-02-01 (73-120)
DC-OF-SM-48D m
CAD
(01 – 72)
FE-ABC-02-01 (01-288)
DC-OF-SM-288D mDC-OF-SM-288D
m
FE-ABC-02-02
(01-240)
CAD
(01 – 216)
FE-ABC-02-01-01 (241-288)
DC-OF-SM-48D m
FE-ABC-02-02-01 (217-240)
DC-OF-SM-48D m
JL.ABC RAYA
JL.ABCI
JL.ABC II
ABC
01/02
ABC
01/yy
DC-OF-SM-288D
m
FE-ABC-02-02
(01-240)
Cable Slack (10m) shall be
placed every 1000m of cable
span and/or the location where
the future demand is expected.
(Note: Do not show on drawing)
( )
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 18 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
1.4.3 PETA LOKASI KABEL FEEDER
STO
ABC
ABC
01/01
DD-BM-HDPE-1
150.0
DD-BM-HDPE-1
35.0
HH-80
HH-2
HH-1 HH-1
DD-BM-HDPE-
BIG-1
150.0
JL.ABC RAYA
JL.ABC II
JL.ABCI
Lokasi BB
ODC-ABC-F -288
Lokasi AA
ODC-ABC-F -144
Lokasi CC
ODC-ABC-F -288
Lokasi DD
ODC-ABC-F -144
DD-BM-1
10.0
DD-BM-1
10.0
DD-ROD-1
15.0m
ABC
01/02
ABC
01/03
ABC
01/xx
DD-BM-HDPE-
BIG-1
bbb.0aaa.0
DD-BM-HDPE-
BIG-1
HH-1
ABC
02/02
ABC
02/01
ABC
02/xx
ABC
01/xx
ABC
01/xx
ABC
01/yy
ABC
02/03
DD-ROD-1
xxx.0m
DD-ROD-1
100.0m
DD-ROD-1
100.0m
DD-ROD-1
100.0m
DD-ROD-1
100.0m
DD-ROD-1
100.0m
DD-ROD-1
100.0m
DD-ROD-1
100.0m
DD-ROD-1
xxx.0m
DD-ROD-1
xxx.0m
1. FE-ABC-01
2. FE=ABC-02
Note:
In case if plural cables
will be installed in one
(1) route, Cable No. to
be installed shall be
indicated.
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 19 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
1.5 CORE ASSIGNMENT DIAGRAM
1. CORE ASSIGNMENT DIAGRAM shall be prepared prior to draw the SKEMA KABELas a tool so as to
arrange the core assignment of the feeder cable easily. (Not for submission purpose)
2. CORE ASSIGNMENT DIAGRAM shall be prepared per each FEEDER CABLE.
3. The higher number of core (e.g. 288 in 288-core cable) shall be assigned from the nearest ODC, and the
youngest number shall be assigned for the furthest ODC or CAD (Spare core).
START
FEEDER CABLE ROUTE PLAN:
=> Draft for Skema Feeder
1. SKEMA DUCT EXISTING shall be referred as the
basic information for the Feeder Cable Route Plan.
2. Plot all ODCs TO BE FED BY THE CABLE
together with its capacity along the existing duct
route.
3. Where the existing duct is not available, new duct
construction or DD-BM-HDPE shall be planned.
4. Plot all prospected/ potential locations including
Al-Pro, MSAN, GDI etc. along the expected
feeder cable route.
Decision of Network
Configuration:
1.Ring
2.Star/Bus
SUM UP the required
number of fiber cores:
1.ODC-144: 24 cores
2.ODC-288: 48 cores
Decision of Feeder Cable Capacity:
1.Required number of cores ≤ 96 → 96C
2.Required number of cores 97 ≥, ≤ 144 → 144
3.Required number of cores 145 ≥, ≤ 288 → 288
4.Required number of cores ≥ 288 → 288 +
another cable according to the required capacity
Preparation of
CORE ASSIGNMENT
DIAGRAM
END
FLOW OF CORE ASSIGNMENT DIAGRAM PREPARATION
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 20 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
1.5.1 EXAMPLE OF CORE ASSIGNMENT DIAGRAM (1): STAR/BUS TOPOLOGY
SKEMA KABEL FEEDER
(Reference for Main Information)
Lokasi AA
ODC-288
(241 – 288)
Lokasi CC
ODC-144
(169 – 192)
Lokasi DD
ODC-144
(145 – 168)
Lokasi BB
ODC-288
(193 – 240)
CAD (72)
(01 – 72)
Lokasi EE
ODC-288
(97 – 144)CAD (24)
(73 – 96)
(01 – 288)
(288) (288) (288)
(01 – 240) (01 – 192)
(145 – 192)
(01 – 72)
(96)
(48) (145 – 168)
(24)
(48)
(97 – 144)
(48)
(193 – 240)
(48)
(241 – 288)
(24)
(169 – 192)
STO ABC
TC-OF-SM-144 (2)
01 - 24
25 - 48
49 - 72
73 - 96
97 - 120
121 - 144
145 - 168
169 - 192
193 - 216
217 - 240
241 - 264
265 - 288
Lokasi AA
ODC-288
(241 – 288)
Lokasi BB
ODC-288
(193 – 240)
STO ABC
Lokasi CC
ODC-144
(169 – 192)
Lokasi DD
ODC-144
(145 – 168)
CAD
(73 – 96)
CAD (72)
(01 – 72)
Lokasi EE
ODC-288
(97 – 144)(288)
(96)
(48)
(48)
(24) (24)
(48) LEGEND:
: Joint Closure
: Fusion Splicing
: Cable (Core)
(XX)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 21 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
1.5.2 EXAMPLE OF CORE ASSIGNMENT DIAGRAM (2): RING TOPOLOGY
Lokasi DD
ODC-288
(145 – 192)
01 24
25 48
49 72
73 96
97 120
121 144
145 168
169 192
193 216
217 240
241 264
265 288
265 288
241 264
217 240
193 216
169 192
145 168
121 144
97 120
73 96
49 72
25 48
01 24
Lokasi AA
ODC-144
(265 – 288)STO ABC
Lokasi CC
ODC-288
(193 – 240)
Lokasi EE
ODC-144
(121 – 144)
Lokasi GG
ODC-288
(49 – 96)
Lokasi BB
ODC-144
(241 – 264)
Lokasi DD
ODC-288
(145 – 192)Lokasi FF
ODC-144
(97 – 120)
CAD
(01 – 48)
CAD
(01 – 48)
SKEMA KABEL FEEDER
(Reference for Main Information)
STO ABC
TC-OF-SM-144 (4)
Lokasi AA
ODC-288
(241 – 288) (01 – 288)
(01 – 288)(01 – 288)
Lokasi BB
ODC-144
(241 – 264)
Lokasi CC
ODC-288
(193 – 240)
Lokasi EE
ODC-144
(121 – 144)
Lokasi FF
ODC-144
(97 – 120)
Lokasi GG
ODC-288
(49 – 96)
(48)
(48)
(48)
(48)
(96)
(96)
(96)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 22 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
1.6 GENERAL CONCEPT FOR FEEDER CABLE DESIGN
1.6.1 ODC SPEC. (Non-HRB Type)
ODC
type
Designator
Splitter
(1:4)
Maximum HP
Feeder
(input Fiber core)
Number of Cable Entry
(Input+Output)
48
(pole)
ODC-C-48 Splitter Max. 6pcs 6x32=192
Star ; 12C
Ring ; 24C
4
96
(pedestal)
ODC-C-96 Splitter Max. 8pcs 8*32=256
Star ; 12C
Ring ; 24C
8
144
(pedestal)
ODC-C-144 Splitter Max. 18pcs 18x32=576
Star ; 24C
Ring ; 48C
12
288
(pedestal)
ODC-C-288 Splitter Max. 36pcs 36x32=1152
Star ; 48C
Ring ; 96C
12
576
(pedestal)
ODC-C-576 Splitter Max. 72pcs 72x32=2304
Star ; 96C
Ring ; 192C
24
1.6.2 FEEDER CABLE SPEC.
Fiber Count Number of Tubes Number of Fiber/Tube Tube Diameter Outer Diameter
Bending Radius
(20 x OD)
12C 2 6 2.1mm 12.8mm 25.6cm
24C 4 6 2.1mm 12.8mm 25.6cm
48C 4 12 2.5mm 13.9mm 27.8cm
96C 8 12 2.5mm 15.6mm 31.2cm
144C 12 12 2.5mm 19.1mm 38.2cm
288C 24 12 2.5mm 22.1mm 44.2cm
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 23 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
1.6.3 HDPE PIPE/HANDHOLE for FEEDER CABLE
In case when the existing duct is not available and new duct (HDPE) will be installed, the following shall be taken into
consideration:
1) Feeder Cable with the capacity 288-core:
► HDPE BIG/SUBDUCT BIG shall be used.
► Hand-hole Type HH-1 (L=1700 x W=1250 x D=1300) shall be used for all locations.
2) Feeder Cable with the capacity 144-core
► HDPE 33/40/SUBDUCT shall be used.
► Hand-hole Type HH-1 (L=1700 x W=1250 x D=1300) shall be used for all locations.
3) Feeder Cable with the capacity 96-core or less
► HDPE 33/40/SUBDUCT shall be used.
► Hand-hole Type HH-2 (L=1200 x W=600 x D=1300) shall be used for all locations
1.6.4 HANDHOLE for ODC
At ODC location, HANDHOLE shall be installed:
1) Type HH-1 (L=1700 x W=1250 x D=1300):
► Where the Jointing Closure from the Feeder Cable with 288/144-core.is installed including the location
where slack is located for future jointing.
2) Type HH-2 (L=1200 x W=600 x D=1300):
► Where Handhole shall be located on the carriage way.
3) Type HH-80 (L=800 x W=800 x D=800):
► Where Handhole will be located on the Green Area (Taman) in the housing area (Perumahan) and where
no jointing closure will be located.
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 24 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
1.6.5 PASS THROUGH CLOSURE for FEEDER CABLE
Through Cable
Type
Model No. (3M)
48core 2179CS Type 1 : 24core tray (1)
Size ; 447mm x 175mm x 107mm
96core, 144core 2179C Type 2 : 24core tray (1)
Type 3 : 24core tray (2)
Size ; 557mm x 215mm x 119mm
288core 2178LS Type 4 : 24core tray (2)
Type 5 : 24core tray (4)
Size ; 557mm x 216mm x 203mm
Option: 24core tray , Re-entry kit
Consultation shall be necessary in case when the other optional items are required.
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 25 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
2. DISTRIBUTION CABLE DESIGN
Maximum Usage of Distribution Cable shall be 80% of the cable capacity:
Maximum No. of ODP: No. of Spare Core (CADANGAN)
1) 8-Core Cable: 6 (Only for Branch Section) 2 CORE CAD.
2) 12-Core Cable: 10 2 CORE CAD.
3) 24-Core Cable: 20 4 CORE CAD.
2.1 GOOGLE MAP
1) ODC (Name/Capacity)
2) Distribution Cable Route
3) Location of ODP
2.2 SKEMA KABEL DISTRIBUSI
► Purpose: Information required for the Distribution Cable Work
1) ODC
ODC Capacity
ODC No. “FA”, “FB”, .......
Code STO
Code ODC
ODC-XXX-FA-288
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 26 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
2) DISTRIBUTION CABLE
DSXXX-FE 01-01-01/01-01-01 (01-24)
Core No. In Cable
Segment No.
Label Feeder (Feeder No., Segment No.)Code STO
DC-OF-SM-24SC-xxM
Cable Length in meter
Designation for “Easy to Split” Cable
No. Of Cores
Type of Cable
Duct Cable: DC-OF-SM
Aerial Cable: AC-OF-SM
Code Distribution Cable
Distribution No.
Branch-Segment No.
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 27 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
3) ODP
FA/D01/xx/yy
(xx)
No. No.
Number of Splitter 1:8
“1”: ODC-8
“2”: ODC-16
ODP No.
Note: 1. Continuous number starting from D01:
example: 10 ODP on D01, ODP on D02 shall be
started from No.11.
2. ODP No. shall be given from the far most ODP
from ODC location.
Distribution Cable No.
ODC No.
Core No. to be terminated at ODP
e.g. from 01 to 24
The largest No. of care shall be allocated to the nearest
ODP from ODC.
House No. in front of
ODP Location
Coordinates Lokasi ODP
Note: Grounding shall be placed at the last ODP for each distribution cable.
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 28 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
2.3 SAMPLE DESIGN OF DISTRIBUTION CABLE NETWORK
1) SKEMA KABEL DISTRIBUSI
2) PETA LOKASI KABEL DISTRIBUSI
2.3.1 CASE-1: UNDERGROUND/DUCT CABLE
ODC-F -144
xx PS 1:4 (yyHP)
DSABC-FE-01-01/01-01 (01-12) DSABC-FE-01-01/01-02 (01-10) DSABC-FE-01-01/01-03 (01-09) DSABC-FE-01-01/01-xx (01-05)
F /D01/07/02
(11-12)
N ...
E .......
N ...
E .......
F /D01/06/01
(10)
N ...
E .......
F /D01/05/01
(09)
ODP-PW-BR
N ...
E .......
F /D01/01/02
(03-04)
N ...
E .......
CAD
(01-02)
DC-OF-SM-12-SC ..m DC-OF-SM-12-SC ..m DC-OF-SM-12-SC ..m DC-OF-SM-12-SC ..m
3 4 9 10 16 17 31
F /D01/04/01
(08)
DSABC-FE-01-01/01-03-01 (08)
DC-OF-SM-8-SC ..m
N ...
E .......
JL. ..
HH-2
ODC-F -144
xx PS 1:4
(yyHP)
DD-BM-HDPE-1 ..m
DD-BM-HDPE-1 ..m
DD-BM-HDPE-1 ..m
DD-BM-HDPE-1 ..m
DD-BM-1 ..m
DD-BM-1 ..m
DD-BM-1 ..m
DD-BM-HDPE-1 ..m
DD-BM-HDPE-1 ..m
DD-BM-HDPE-1 ..m
DD-BM-1 ..m
DD-BM-HDPE-1 ..m
DD-BM-1 ..m
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 29 30
31
32
DD-BM-HDPE-1 ..m
F /D01/07/02 F /D01/06/01
F /D01/05/01
ODP-PW-BR F /D01/01/02
F /D01/04/01
JL. ..
Note:
At the BRANCHING, the core
assignment and the ODP No. shall be
in accordance with the rule below.
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 29 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
STO ABC NAMA LOKASI Cluster AA (ODC-F -144)
DISTRIBUTION
CABLE No.
D-01 CAPACITY 12-CORE
FEEDER SEGMENT DISTRIBUTION SEGMENT
OTB
Port No.
ODC
PORT No.
SPLITTER 1:4 ODC TRAY CORE
No.No. Port No. PORT No.
49 1 1
1
1
1 1
2 2 2
3 3 3
4 4 4
50 2 2
1 5 5
2 6 6
3 7 7
4 8 8
51 3 3
1 9 9
2 10 10
3 11 11
4 12 12
7 6 5 4 3 2
3) CORE ASSIGNMENT DIAGRAM (For CASE-1)
1
CAD
8-C
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 30 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
2.3.2 CASE-2: AERIAL CABLE
1) SKEMA KABEL DISTRIBUSI
2) PETA LOKASI KABEL DISTRIBUSI
ODC-F -144
xx PS 1:4 (yyHP)
DSABC-FE-01-01/01-01 (01-12) DSABC-FE-01-01/01-02 (01-11) DSABC-FE-01-01/01-03 (01-10) DSABC-FE-01-01/01-xx (01-05)
F /D01/08/01
(12)
N ...
E .......
N ...
E .......
F /D01/07/01
(11)
N ...
E .......
F /D01/06/01
(10)
ODP-PW-BR
N ...
E .......
F /D01/01/01
(05)
N ...
E .......
CAD
(01-04)
AC-OF-SM-12-SC ..m AC-OF-SM-12-SC ..m AC-OF-SM-12-SC ..m AC-OF-SM-12-SC ..m
3 4 9 10 16 17 31
F /D01/05/01
(09)
DSABC-FE-01-01/01-03-01 (09)
AC-OF-SM-8-SC ..m
N ...
E .......
JL. ..
HH-2
ODC-F -144
xx PS 1:4
(yyHP)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 29 30
31
32
F /D01/08/02 F /D01/07/01
F /D01/06/01
ODP-PW-BR F /D01/01/01
F /D01/05/01
JL. ..
BC-PP 3m 30m 45m 45m 45m
45m
25m.m
LEGEND
: New Pole
: Existing Pole
Branching ODP
(1 x 1:8 Splitter)
ODP Aerial
(1 x 1:8 Splitter)
30m
Note:
At the BRANCHING, the core
assignment and the ODP No. shall be
in accordance with the rule below.
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 31 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
3) CORE ASSIGNMENT DIAGRAM (For CASE-2)
STO ABCABCABCABC NAMA LOKASI Cluster AA (ODC-F -144)
DISTRIBUTION
CABLE No.
D-01 CAPACITY 12-CORE
FEEDER SEGMENT DISTRIBUTION SEGMENT
OTB
Port No.
ODC
PORT No.
SPLITTER 1:4 ODC TRAY
CORE No.
No. Port No. PORT No.
49494949 1111 1111
1
1111
1 1
2 2 2
3 3 3
4 4 4
50505050 2222 2222
1 5 5
2 6 6
3 7 7
4 8 8
51515151 3333 3333
1 9 9
2 10 10
3 11 11
4 12 12
ODP No. 15 34 2678
CAD
12-C 12-C
8-C
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 32 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
Main Cable
(SCPT-8/12/24-core)
ODP Pedestal/Wall
Capacity: 8 or 16
ODP Pedestal/Wall
Capacity: 8 or 16
Branching Cable
(SCPT-8-core)
Branching ODP
(1 x 1:8 Splitter)
Designator:
ODP-PL-BR
2.4 BRANCHING ODP
1) Underground Cable
(Pedestal/Wall Mount)
Branching ODP shall be used in case when the several ODP locations are not suitable to be fed by the main cable but
independent cable installation is also not efficient due to the limited number of ODP (Less than 8 ODP).
Branching ODP:
1)Branching ODP is applicable for both underground as well as aerial distribution cable design.
2)Type of ODP is “Cabinet” type to be mounted on: WALL, POLE and PEDESTAL.
3)The cable to be branched from the main cable shall be of “8-Core”.
4)The number of ODP on branched cable shall be less than 8.
5)The branching ODP is able to accommodate only one (1) unit of 1:8 Splitter.
2) Aerial Cable
(Pole Mount)
Main Cable
(SSW-8/12/24-core)
ODP Aerial
Capacity: 8
ODP Aerial
Capacity: 8Branching Cable
(SCPT-8-core)
Branching ODP
(1 x 1:8 Splitter)
Designator:
ODP-P/W-BR
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 33 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
2.5 DUCT USAGE FOR DISTRIBUTION NETWORK &
DROP-CORE INSTALLATION (UNDERGROUND)
ODC – ODP/ ODP – ODP
1)DD-BM-HDPE
2)BC-TR-1.5 + DD-HDPE
ODP (HH-PIT-60) – HH-PIT-40/
HH-PIT-40 – HH-PIT-40
1) BC-TR-0.6 + DC-SD-1 BigHH-PIT-60
HH-PIT-40
HH-PIT-40
HH-PIT-40 - Premises
1) BC-TR-0.4 + PP-OF-OUT(PVC ¾”)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 34 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
3. GENERAL CONCEPT FOR DISTRIBUTION CABLE DESIGN
1) Bila ditemukan jalan buntu pada perumahan dengan jalak Drop core <100 meter maka
penempatan ODP diletakkan di ujung jalan masuk Blok Perumahan, Gambar Terlampir:
1) When you find a blind alley which need drop core cable less than 100 m, the ODP should be placed at
the entrance of the alley. Please see the illustration below.
General Preparation for the Distribution Cable Design:
Prior to plotting ODP on the map, ODP Boundary (Max. 8 or 16HP) shall be designated so
that the number of ODP and its location can be planned efficiently.
3.1 DUCT/BURIED SECTION
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 35 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
2) Bila ditemukan jalan buntu pada perumahan dengan jalak Droop core >100 meter maka
diperbolehkan menggunakan ODP Branch dari kabel distribusi untuk kabel yang akan menuju ke
ODP dengan jumlah branch sesuai denga HP, Gambar Terlampir :
2) When you find a blind alley which need drop cable more than 100 m, it is allowed to use the ODP Branch from the
main distribution cable according to the quantity of HP. Please see the illustration below.
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 36 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
3) Bila ditemukan jalan tidak buntu pada perumahan maka penarikan kabel distribusi dapat dilakukan
secara mengelilingi perumahan yang letak ODP di sesuaikan dengan jumlah HP, Gambar Terlampir :
3) When it is not a blind alley, span of the cable should pass around the complex and placement of ODP should be
adjusted according to the HP. Please see the illustration below.
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 37 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
3.2 AERIAL SECTION
1) Sample Design based on Duct Cable Design Standard
=> (Some consideration due to particularity of the aerial cable shall be required.)
6.5m 45m
6.5m
30m
45m
45m
40m
45m
45m
45m11m
45m
45m
25m
25m
6.5m
35m
45m
45m
45m
Road width
more than 6m
Road width
less than 6m
AC-OF-SM-12-SC
AC-OF-SM-8-SC
AC-OF-SM-8-SC
AC-OF-SM-12-SC
ODP-BR
ODP-BR
Note: Location where special
consideration is required due
to a particularity of the aerial
cable installation
: ODC
: ODP
1) ODP-SSW-8
2) ODP-BR
: HH-2/HH-80
: New Pole 7m/9m
LEGEND
C-CLAMP x 2
Detail for Riser Part
SSW CABLE
Cable part shall be
protected with Spiral
for outdoor use (Black
color)
Detail for
Riser Part
Note: Prior to plotting ODP on the map, ODP Boundary (Max. 8HP) shall be designated so that the number
of ODP and its location can be planned efficiently.
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 38 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
2) Sample Design based on Particularity for Aerial Cable
: Additional Pole for
Drop Core
LEGEND for Additional Item
: Drop Core Run
6.5m
45m
6.5m
40m
45m
45m
40m
45m
45m
45m
11m
45m
45m
25m
25m
6.5m
35m
45m
45m
45m
Road width
more than 6m
Road width
less than 6m
30m
35m
10m
15m
25m
30m
30m
40m
35m
25m
35m
Detail "Drop-A"
Detail "Drop-B" Detail "Drop-C"
Note: Location where special
consideration is taken due to
a particularity of the aerial
cable installation
Some particular consideration required for
Aerial Cable Design
1. Additional pole(s) may be required for the
drop cable installation. (Actual installation
of additional poles shall be decided in
accordance with contract with the
developper/owner)
2. Road width less than 6m can be crossed by
the drop cable as far as the road traffic will
not be disturbed otherwise new pole shall
be installed.
3. Location of ODP shall be decided so that:
1) Drop cable can be installed along SSW
cable.
2) Drop cable can be installed indipendently
for one (1) span (2 spans at maximum)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 39 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
C-CLAMP x 2
SSW CABLE
Cable part shall
be protected with
Spiral for outdoor
use (Black color)
3) Details of SSW Installation
A. Details of Riser Part B. ODP-SSW Location
10cm
ODP-SSW-8
B-1. With C-CLAMP
C. Cable Allignment
As far as it is practical, the
cable shall be installed so
that the suspension wire is
always above the cable part.
Suspension Wire
Cable Part
At the cable laying, turns in
the cable shall be released
by turning the cable winding
while making the 8-figure.
50mm
Bend
150mm remove sheath
D. C-LAMP E. Line Guard Installation
±30cm
Line Guard
L= 51cm
ODP-SSW-8
B-2. With LINE GUARD
SUSPENSION CLAMP
±25cm
< 120°°°°
LINE GUARD shall be installed where:
1. One (1) in every three (3) poles in the
straight line.
2. At the pole beside the ODP-SSW is
installed except the location where C-
CLAMP is installed.
Caution:
LINE GUARD shall be fixed and the Suspension
Wire at C-CLAMP shall be bent ONLY after all
ODP-SSW installation have been completed
and the cable allignment has been confirmed
so that no turn is contained in the cable span.
: SSW Cable (Japan)
LEGEND
: C-Clamp (Japan)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 40 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
Drop Cable
(Aerial)
HC-OF-SM-2D
4) Details of Drop-Core Solution
Detail "Drop-A"
Messenger wire from drop cable to pole or
φ1.2mm galvanized steel wire with sheath coating
Detail "Drop-B"
Detail "Drop-C"
: S-Clamp (Japan)
LEGEND
: D-Clamp (Japan)
: BW-Clamp (Local)
FUSE-CONNECT
ISC-UPC-FD
ROSETTE
RS-IN-SC-1P/
TC-MK-SC-1P
Details of "Home Connect"
ODP-SSW-8
ODP-PL/PW-
8/16
Drop Cable
(Underground)
GC-OF-SM-2D
Wire Grip 3/8"
with double nut
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 41 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
4. CABLE RACK/OTB RACK IN STO BUILDING
Note:
1. The cable routing in the STO building shall be
measured so as to estimate the cable length
from the duct entrance at the Cable Chamber
until the OTB.
2. In case when the new rack shall be provided, the
rack to be installed shall be of same type and
the same color with the existing one.
3. In the decision of the location of 19” rack
installation, well coordination with DBB, Telkom
Area and/or WASPANG is required.
4. When the location of new 19” Rack installation
is fixed, the designated location on the floor
shall be clearly marked with an adhesive tape
and a permanent marker as:
“FTTH OSP
JF DJAFa”
5. The maximum number of unit of TC-OF-SM-144
to be accommodated in the 19” Rack with
Height of 2.20m shall be FIVE (5).
CABLE
CHAMBER
MDF
ROOM OTB ROOM/
TRANSMISSION
ROOM
19”RACKH=2200
Max.5xTC-OF-SM-144
FEEDER
CABLE
STO BUILDING
CABLE RACK
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 42 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
5. HIGH-RISE BUILDING (HRB) DESIGN
No. Designator Application No. of Splitter
(Max.)
Number of Port Home Pass
Accommodated (80%)In Out Total
1. ODC for HRB/MDU (Approx.)
1.1 ODC-HRB-180 (*) Cabinet/ Wall 1:4 x 36 36 144 180 900
1.2 ODC-HRB-240 (*) Cabinet 1:4 x 48 48 192 240 1200
1.3 ODC-HRB-420 (*) Cabinet 1:4 x 84 84 336 420 2200
1.4 ODC-HRB-RACK-120 (**) 19" Rack Mount 1:4 x 24 24 96 120 600
1.5 ODC-HRB-RACK-240 (**) 19" Rack Mount 1:4 x 48 48 192 240 1200
1.6 ODC-HRB-RACK-480 (**) 19" Rack Mount 1:4 x 96 96 384 480 2500
2. ODP for HRB/MDU (Installed) (Max.)
2.1 ODP-HRB-16 (*) Wall Mount
1:8 x 1 - 8 8
16
1:8 x 2 - 16 16
2.2 ODP-HRB-32 (*) Wall Mount
1:8 x 3 - 24 24
32
1:8 x 4 - 32 32
3. 2-C Low Friction Indoor Cable
3.1 IC-OF-SM-1D
Distribution/ Drop-core
1-Core (G657A) Low Friction Indoor Cable for DISTRIBUTION-CABLE
3.2 IC-OF-SM-2D 2-Core (G657A) Low Friction Indoor Cable for DROP-CABLE
1-Core connected with Fuse-Connect (ISC-UPC-FD), 1-Core for spare
4. ROSETTE SC Adapter
4.1 RS-IN-SC-1P 1
Indoor Rosette4.2 RS-IN-SC-2P 2 To be discussed when necessary (***)
4.3 RS-IN-SC-4P 4 To be discussed when necessary (***)
4.4 TC-MK-SC-1P 1
Indoor Rosette (Buried in
wall)
4.5 TC-MK-SC-2P 2 To be discussed when necessary (***)
4.6 TC-MK-SC-4P 4 To be discussed when necessary (***)
5.1 MATERIAL FOR HRB SOLUTION
Note (*): New Item (Specifications have been accepted by TELKOM)
(**): New Item (Specifications shall be subject to concurrence by TELKOM)
(***): To be discussed with DBB TELKOM when 2P or 4P Rosette is required by the Developer
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 43 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
1-Core Low Friction Indoor Cable for
1x 1:8 Splitter with Field Installable SC Connector
(Fuse-connect) x 1pc at both ends
ODC-HRB-
1) 180
2) 240
3) 420
ODC-HRB-RACK-
1) 120
2) 240
3) 480
Feeder Cable:
1) For ODC-HRB-180: 24/48C
2) For ODC-HRB-240: 48C
3) For ODC-HRB-480: 96C
ODP:
1) ODP-HRB-16: Up to 16 HP (1or 2 x 1:8 Splitter)
Size: H=330 x W=260 x D=130
2) ODP-HRB-32: Up to 32 HP (3 or 4 x 1:8 Splitter)
Size: H=412 x W=312 x D=140
ODP-
HRB
Cable Tray/Shaft/Ladder
Rosette: TC-MK-SC-xP
(1-Port/2-Port/4-Port)
2-Core Low Friction Indoor Cable
with Field Installable SC Connector
(Fuse-connect) x 1pc at both ends
ODP-
HRB
4) For ODC-HRB-RACK-120: 24C
5) For ODC-HRB-RACK-240: 48C
6) For ODC-HRB-RACK-480: 96C
5.2 DESIGN CONCEPT FOR HRB SOLUTION
DESIGN CONCEPT FOR HRB
1. ODC shall be selected among all types
according to the site situation as well as
number of Home Pass of the target
building.
2. ODP shall be selected among three (3)
types according to the number of Home
Pass and the Floor Layout.
3. 2-Core Low Friction Indoor Cable shall
be used between ODC and ODP.
4. One (1) Low Friction Indoor Cable shall
be connected ODC Port with one (1) 1:8
Splitter of ODP i.e.:
1) ODP-HRB-16: One (1) or two (2) Low
Friction Indoor Cable:
a. 1 x 1:8 Splitter: 1 Low Friction Cable
b. 2 x 1:8 Splitter: 2 Low Friction Cables
2) ODP-HRB-32: Three (3) or four (4) Low
Friction Indoor Cables:
a. 3 x 1:8 Splitter: 3 Low Friction Cables
b. 4 x 1:8 Splitter: 4 Low Friction Cables
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 44 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
5.3 Type of ODC for High-Rise-Building
1) CABINET TYPE 2) RACK MOUNT TYPE
(To be mounted in the Closed Rack H=1.20m)
H= 770
W=555
D=310
ODC-HRB-180
Application: Wall/Floor
D=360
H= 1450
W=750
ODC-HRB-240/420
Application: Floor
W=428
H= 275
D=302.3
ODC-HRB-RACK-120
Application: 19" Rack
W=428
D=302.3H= 445
ODC-HRB-RACK-240
Application: 19" Rack
W=428
D=302.3
H= 890
ODC-HRB-RACK-480
Application: 19" Rack
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 45 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
5.4 Example of Cable Tray/Trunking
1) HORIZONTAL RUN
(a) On the Cable Tray
Cable Tray
Cable Trunking
(b) Direct Attachment to the Building Wall
2) VERTICAL RUN
ODP-
HRB
Elbow (Flat Angle)
T-Joint
Cable Trunking
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 46 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
5.5 SAMPLE DESIGN: SKEMA DISTRIBUSI
ODC ABC BUILDING
F.../STO/HRB-xxx
xx PS 1:4 (xxx HP)
S 6
E 106 ...
x IC-OF-SM-1D __m x IC-LF-OF-SM-1D __m
x IC-OF-SM-1D __m
2 IC-OF-SM-1D__m
x IC-LF-OF-SM-1D __m
1 IC-LF-OF-SM-1D __m 2 IC-OF-SM-1D __m
x IC-OF-SM-1D __m
x IC-OF-SM-1D __m
F /P01-02/1/2
ODP-HRB-16
F /P03/2/1
ODP-HRB-16
(Note: Not "8")
ODC No.
Code STO
"HRB"-"Capacity"
180
240
420
No. of Splitter No. of Home Pass
No. of Splitter 1:8
ODP No.
ODC Port No.
Each No. to be given for Each 1-Core
Indoor CableODC No.
Specify "Tower" and/or
"Shaft" according to the
Building Layout.
F /P04-05/3/2
ODP-HRB-16
2: No. of Indoor Cable to be installed and
terminated to ODP
__m: Cable Length from ODC to ODP
Tower A/
Shaft No.1
Floor-xx
Floor-yy
Floor-zz
Descriptions for ODC
1.1.1.1.ODC XXX (Name of Building)
2. F... /STO /HRB-(RACK)-xxx
3. xx PS 1:4 (xxx HP)
4. Coordinates
1. F / P-03/ 2/ 1
Descriptions for ODP
2. ODP-HRB-xx
Type of ODP: ODP-HRB-16, 32 (See Note above.)
Note:
Type of ODP-HRB is 2:
1. ODP-HRB-16: No. of 1:8
Splitter= 1 or 2
2. ODP-HRB-32: No. of 1:8
Splitter= 3 or 4
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 47 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
5.6 SAMPLE DESIGN: PETA LOKASI DISTRIBUSI
1) PETA LOKASI KABEL DISTRIBUSI (Vertical View)
Tower A
F /P03/2/1
ODP-HRB-16
Note: Not "8"
F /P04-05/3/2
ODP-HRB-16
ODC ABC BUILDING
F.../STO/HRB-xxx
xx PS 1:4 (xxx HP)
F /P01-02/1/2
ODP-HRB-16
Cable Shaft No.1 Cable Shaft No.2
Cable Tray/Trunking to be installed
e.g. Cable Tray W=100mm x 35m
1
LEGEND
: ODC-HRB
: ODP-HRB
: Cable Tray/Trunking
(New)
2
: Rosette (1-Port)
: Rosette (2-Port)
: Cable Tray/Trunking
(Existing)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 48 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
2 31
LIFT
11
4 5 6 7 8 9 10
19
31
22
32 33 34 35 36 37 38 3930
18
23
17
24
16
25
15
26
14
27
13
28
1 1 1
1 1
1
1 1 1 1 1
1 1 1 1 1 1
12 20
2129
F /P01-02/1/2
ODP-HRB-16
F /P03/2/1
ODP-HRB-16
Note: Not "8"
F /P04-05/3/2
ODP-HRB-16
2) PETA LOKASI DROP-CORE (Floor Plan)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 49 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
Table-1: List of Port Management
ODC Port
No.
Distribution
Cable No.
ODP
Unit No.
Drop Cable
Length (m)No./Floor Splitter No. Port
1 D01
8
1
1 1 30.0
2 2 18.0
3 3 10.0
4 25 55.0
5 26 50.0
6 27 45.0
7 28 40.0
8 29 35.0
2 D02 2
1 11
12
30
31
32
33
34
35
6
7
8
3) LIST OF PORT MANAGEMENT & DROP-CORE LENGTH
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 50 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 51 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
6.1 PONDASI ODC-C-144 Splitter
Keterangan:
Pondasi dan lantai kerja berlapis keramik.
1. Pondasi: Keramik 20 x 20, warna biru
2. Lantai kerja: Keramik 20 x 20 Non-slip, warna biru
310mm
1035mm
555mm
463
170
500600
660
360150 150
ODC Foundation: A-A
(Not to scale/ Unit: mm)
98.5 98.5
75 – 85mm
Drill:Ф14mm/ d= 75 – 85mm
(Expansion Bolt: M8 x 150)
1100
463
G.L
52.5 52.5555
ODC Foundation: B-B
(Not to scale/ Unit: mm)
440
150 150140
115 115170
75 – 85mm
Drill:Ф14mm/ d= 75 – 85mm
(Expansion Bolt: M8 x 150)
G.L
31065 65
ODC Foundation: Top View
(Not to scale/ Unit: mm)
150150140
440
150 150360
660
440
135135170
660
98.5
98.5
463
Drill:Ф14mm/ d= 75 – 85mm
A A
B
B
(Expansion Bolt: M8 x 150)
ODC Foundation
Conduit Connection
(Not to scale/ Unit)
R > 500mm
W=600
(HH-2)
Handhole
Type:HH2
5 x HDPE 33/40
(B-B Side)
Approx.30cm or less
Approx. 30cm
G.L.
- 200
± 0
- 1500
- 1000
Handhole
Type:HH-80
W=800
(HH-80)
- 600
Special Attention:
Cable Slack shall be placed only in
HANDHOLE/HH-PIT and never be
located in the ODC Foundation.
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 52 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
6.2 PONDASI ODC-C-288 Splitter
150150140
440
165 165520
850
440
120120200
850
119 119612
Drill:Ф18mm/ d= 60 – 80mm
ODC Foundation: Top View
(Not to scale/ Unit: mm)
A A
B
B
(Expansion Bolt: M12 x 150)
320mm
1450mm
750mm
ODC Mount and
Location of Anchor
Bolt
612
200
ODC Foundation: A-A
(Not to scale/ Unit: mm)
G.L
500600
850
520165 165
119 119
60 – 80mm
Drill:Ф18mm/ d= 60 – 80mm
(Expansion Bolt: M12 x 150)
1100
612
50 50750
Keterangan:
Pondasi dan lantai kerja berlapis keramik.
1. Pondasi: Keramik 20 x 20, warna biru
2. Lantai kerja: Keramik 20 x 20 Non-slip, warna biruODC Foundation: B-B
(Not to scale/ Unit: mm)
440
150 150
120 120200
60 – 80mm
Drill:Ф18mm/ d= 60 – 80mm
(Expansion Bolt: M12 x 150)
G.L
60 60320
140
Conduit Connection
(Not to scale/ Unit)
R > 500mm
W=600
(HH-2)
Handhole
Type:HH2
5 x HDPE 33/40
(B-B Side)
Approx.30cm or less
Approx. 30cm
G.L.
- 200
± 0
- 1500
- 1000
Handhole
Type:HH-80
W=800
(HH-80)
- 600
ODC Foundation
Special Attention:
Cable Slack shall be placed only in
HANDHOLE/HH-PIT and never be
located in the ODC Foundation.
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 53 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
500
100 300 100
TELKOM
500
100100
300
Ф 300
PVC 4"
Sub-duct BIG
500
700
200150150
100100
Distance in accordance with
the site situation.
Jarak sesuai kondisi lapangan.
150 150400
700
900
100 100
Sub-duct BIG
PVC 4"
PVC 4" for
Drop Cable
L=300
PVC 4" for
Distribution Cable
L=300
450150
900
600150 150
150
600
150
900
700
150
500
200150 150
100 100
150
100
80220
H(*)600-H
600
500
100 100Ф 300
150 150400
700
LARGE RADIUS ELBOW
PVC 4"
(WAVIN D-LL 4" or Equivalent)
PVC4"L=±650
Distance in accordance with
the site situation.
Jarak sesuai kondisi lapangan.
6.3 PONDASI ODP PEDESTAL & HH-PIT-60
Cable Installation Method between HH-PIT-60 and ODP
Distribution Cable Installation
shall cautiously be carried out
so that the Bending Radius of
20cm shall be secured.
Note “H”: Height above ground
shall be minimum 10cm. Actual
height shall be in accordance
with the site condition.
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 54 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
1300
250150900
250 1000
1250
288-C cable
R= 44.2mm
+- 150cm
557mm
450625 625
1700
1300
250150+-90cm
450625 625
PASS-THROUGH CLOSURE ARRANGEMENT IN HH-1
(288-C Loose Tube Cable / 3M Type 2178LS)
BESI 70 x 50 x 3
150 1501250
1550
100 1001350
200 200950
1550
Hole Ф20mm
Ф10mm x 125mm
POT B - B
Ф12mm x 125mm
PVC Ф4" x 4
L= 300
1
5
0
1
5
0
1
5
0
1
5
0
Ф10mm x
125mm
BETON: 225kg/cm²
150 1501700
2000
2001501300
1650600 600100 100
200 200 200200 200 200
Ф10mm x 125mm
Ф10mm x 125mm
POT A - A
600
200 200 200
Ф12mm x 125mm
150150
L=300
T
E
L
K
O
M
T
E
L
K
O
M
T
E
L
K
O
M
150150150950
1550
A A
B
B
100200200200 200 200200
2000
200 200100
1350
3 x 600 = 1800
150
TELKOM
200
TELKOM
TELKOM
6.4 HH-1: Dimensi Dalam (P=1700 x L=1250 x T=1300)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 55 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
BESI 70 x 50 x 3
150 150600
900
100 100700
150 150400
900
Hole
Ф20mm
Ф10mm x 125mm
POT B - B
PVC Ф4" x 4
L= 300
150
150150
150
T
E
L
K
O
M
100 225 225 100200 225225 200
1500
150150150300
900
A A
B
B
T
E
L
K
O
M
2 x 650 = 1300
700
150
PVC Ф4" x 4
L= 300
150 1501200
1500
2001501300
1650
650 650100 100
225 200 225225 200 225
150
Ф10mm x 125mm
Ф10mm x 125mm
POT A - A
150
L=300
6.5 HH-2: Dimensi Dalam (P=1200 x L=600 x T=1300)
BETON: 225kg/cm²
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 56 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
6.6 HH-80: Dimensi Dalam (P=800 x L=800 x T=800)
150150 800
1100
150
Ф10mm x 125mm
Ф10mm x 125mm
200150800
1150100
200
450
1100
125
150
L=300
450 100
125 200125 125
POT A - A
Hole Ф20mm
150
150150 PVC Ф4" x 4
L= 300
BESI 70 x 50 x 3
Ф10mm x 125mm
150 150
800
1100
200150800
1150
1100
100 100900
150 150600
150
POT B - B
B
T
E
L
K
O
M
1100
150
100
1100
A A
B
1100
PVC Ф4" x 4
L= 300
900
T
E
L
K
O
M
150
100
600
100
125
100
200
450
1100
450
125 125 200 125
BETON: 225kg/cm²
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 57 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
G.L.
Approx.2.20m
10cm
30cm
10c
m
30cm
Approx.
10cm
Clampsshallbeattached
Approx.@<1.0m
ClampsshallbeattachedApprox.
@<1.0m
Gap between steel pipe (Ф
2") and ODP (Wall Mount)
shall be less than 10cm
Galvanized Steel Pipe (Ф2")
and Clamps shall be painted
with the same color with the
wall.
Approx.
10cm
Approx.
10cm
Approx.
10cm
B (See detail.)
A (See
detail.)
Approx.
5cm
Gap between steel pipe (Ф
2") and ODP (Wall Mount)
shall be less than 10cm
Identification Marking
(White color) shall be
applied on the cable of
"Up-stream/ODC" side.
In case Gap between
steel pipe (Ф 2") and ODP
(Wall Mount) is more than
5cm, cables shall be
protected with spiral or
flexible pipe (Black color)
HDPE Pipe 33/40
Ф 2" Galvanized Steel Pipe
Details "A"
30cm
10cm20cm
30cm
30cm
G.L.
HDPE 33/40 shall be
installed until the level with
Galvanized Steel Pipe..
Details "B"
6.7 INSTALLATION OF ODP WALL (1)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 58 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
Flex. Pipe
OD=25mm
Steel flexible inside
HH PIT-60
150 Flex-pipe
R≧300
Approx.
200
Appro
x. 100
Approx. 100
Approx. 100
Flex-pipe R≧300
Flex-pipe
R≧300
Flex-pipe
R≧300
Flex-pipe
R≧300
PVC Simple
Socket for OD
25mm Pipe
PVC/High-Impact
Conduit OD Ф25mm
PVC/High-Impact
Conduit OD Ф25mm
Pipes shall be buried in the wall.
Pipe space shall be filled with
concrete after ODP installation.
150
Approx.
200
100
50
Approx.
100
HH PIT-60
Note:
In case when pipes shall be buried in the building wall due to the
requirement by the developer, the following points shall be taken into
account for the installation.
1. HH-PIT-60 shall be installed in front of ODP location.
2. Flexible Pipe with steel (OD 25mm) shall be used at the bending part of
conduit.
3. Bending Radius of Flexible Pipe shall be more than 300mm.
4. PVC/High-Impact Pipe (OD 25mm) shall be used at the straight part of
conduit.
5. PVC Simple Socket for OD 25mm Pipe shall be used at all jointing part.
6. Pipe space of wall shall be filled with concrete after installation of ODP.
(ODP termination work shall be done prior to the pipe fixing and concrete
work.)
7. The wall shall be restored to the original condition and painted with the
same color with the original wall.
MOM/BA shall be made (to be signed by the PIC of the developer) for the
confirmation of the requirement.
2 x PVC Ф50
(L=200)
Pipes shall be buried in the wall.
Pipe space shall be filled with
concrete after ODP installation.
Drop Cable
6.7 INSTALLATION OF ODP WALL (2)
(In case pipe shall be buried in the wall)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 59 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
6.8 FORM FOR CORE ASSIGNMENT
6.8.1 FEEDER CABLE (STAR TOPOLOGY: 24 CORE BASE)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 60 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
6.8.2 FEEDER CABLE (STAR TOPOLOGY: 12 CORE BASE)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 61 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
6.8.3 FEEDER CABLE (RING TOPOLOGY)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 62 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
6.8.4 DISTRIBUTION CABLE
No. Port No. PORT No.
CORE ASSIGNMENT DIAGRAM (DISTRIBUTION CABLE)
CAPACITY -CORE
OTB
Port No.
SPLITTER 1:4
CORE No.
ODC
PORT No.
ODC TRAY
DISTRIBUTION CABLE No.
4
3
4
1
2
D-
2
3
4
1
2
3
4
1
2
3
3
4
1
2
3
4
1
2
1
19
20
21
22
23
24
13
14
15
16
17
18
7
8
9
10
11
12
1
2
3
4
5
6
FEEDER SEGMENT
1
2
3
4
1
2
3
4
5
6
7
8
9
10
STO
11
12
5
6
7
8
DISTRIBUTION SEGMENT
ODP No.ODP No.ODP No.ODP No.
NAMA LOKASI
9
10
11
12
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 63 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
TipeProduct:ODC-C-144
Tgl.Instalasi
NamaLokasi
NamaInstaller
CategoryItems
1.AksesorisCableband(M)
Cableband(L)
SpiralTube
Compound
Cabletie
Assemblymanual
PVCtape
2.PondasiODCBautexpansiontidakkendur
3.LubangKabelMasuk(Feeder&Distribusi)
4.CableclampClampuntuktensionMembertidakkendur
CableBandtidakKendur
5.RuteLooseTubeTidakadasmallbending(diameter>60)
tidakterjepitdengantutuptray
Tidakadasmallbending(diameter>60)
tidakterjepitdengantutuptray
7.RutePigtaildalamTrayArahRute(bentukS)
Tidakadasmallbending(diameter>60)
tidakterjepitdengantutuptray
8.InstalasiSplittermodul
rutesesuaipetunjukmanual
Tidakadasmallbending(diameter>60)
tidaksalingtersangkutdanmudahdiurai
10.SCconnectorpatchingKonektortercolokdenganbenar(sampaibunyiklik)
diperiksaoleh:
(Sitemanager)
Catatan
ArahdanPosisiSplitterharusbenar(Input:bawah;
Output:atas)
PenggunaanCompoundharusrapat(tidakadacelah)
InstallationCheckSheet
pcs
pcs
pcs
pc
pcs
9.RutekabeldariSplitterkeTray
pc
pc
Check
*2buahkunciODCharussudah
diterimasitemanager
*ceksisaaksesorisyangdiperlukan
untukinstalasikabelberikutnyadanuntuk
maintenance
6.RuteFiberdidalamTray
6.9 INSTALLATION CHECK SHEET
6.9.1 INSTALLATION CHECK SHEET: ODC-C-144
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 64 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
6.9.2 INSTALLATION CHECK SHEET: ODC-C-288
TipeProduk:ODC-C-288
Tgl.Instalasi
NamaLokasi
NamaInstaller
CategoryItems
1.AksesorisCableband(M)
Cableband(L)
SpiralTube
Compound
Cabletie
Assemblymanual
PVCtape
2.PondasiODCBautexpansiontidakkendur
3.LubangKabelMasuk(Feeder&Distribusi)
4.CableclampClampuntuktensionMembertidakkendur
CableBandtidakKendur
5.RuteLooseTubeTidakadasmallbending(diameter>60)
tidakterjepitdengantutuptray
Tidakadasmallbending(diameter>60)
tidakterjepitdengantutuptray
7.RutePigtaildalamTrayArahRute(bentukS)
Tidakadasmallbending(diameter>60)
tidakterjepitdengantutuptray
8.InstalasiSplittermodul
rutesesuaipetunjukmanual
Tidakadasmallbending(diameter>60)
tidaksalingtersangkutdanmudahdiurai
10.SCconnectorpatchingKonektortercolokdenganbenar(sampaibunyiklik)
Diperiksaoleh
(Sitemanager)
Catatan
ArahdanPosisiSplitterharusbenar(Input:kiri;
Output:kanan)
*2buahkunciODCharussudah
diterimasitemanager
InstallationCheckSheet
Check
pcs
pcs
pcs
pc
pcs
*ceksisaaksesorisyangdiperlukan
untukinstalasikabelberikutnyadanuntuk
maintenance
6.RuteFiberdidalamTray
9.RutekabeldariSplitterkeTray
pc
pc
PenggunaanCompoundharusrapat(tidakada
celah)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 65 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
ProductType:ODP-CA-8/16-WP
InstallationDate:
InstallationSite:
InstallerName:
CategoryItemsCheck
1.AccessoryCabletiepcs
Expansionscrewsets
Dropcablefixingclamppcs
Bukumanualpc
PVCtapepc
2.InstalasiSplitterArah:input:kiri;output:kanan,labelterlihat
PosisiSplitter:No1palingatas
Tidakadasmallbending(diameter>60)
KabelTidakterjepitatautersangkutjikadibuka
PosisiKonektor
4.LubangTempatkabelmasuk
5.clampKabelClampuntukTensionmemberTidakkendur
Clampuntukkabeltidakkendur
6.RutekabelSCPTPassthroughTidakadasmallbending(diameter>60)
TidakterjepitdantersangkutjikaODPdibuka
7.ClampdanruteSCPTyangditerminasipastikanpenggunaankabelTiesditigatitik
Tidakadasmallbending(diameter>60)
tidakterjepitdantersangkutjikaODPdibuka
8.RuteFibersetelahSplicingTidakadasmallbending(diameter>60)
tidakterjepitdantersangkutjikaODPdibuka
Diperiksaoleh:
(Sitemanager)
Catatan
pemasangantempatmasukkabelharusrata,tidakmiring
InstallationChecksheet
*1buahkunciODPharussudah
diterimasitemanager
tidakadacelah(penggunaansolasiataugrommet
harusdapatmenutupcelah)
adadisebelahkanan,
BariskonektorpalingbawahuntukSplitterno.1
*ceksisaaksesorisyangdiperlukan
untukinstalasikabelberikutnyadanuntuk
maintenance
3.instalasioutputSplitterpadapanel
Adapter
6.9.3 INSTALLATION CHECK SHEET: ODP-PL/PW-8/16
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 66 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
ProductType:TC-SM-144
InstallationDate:
InstallationSite:
InstallerName:
CategoryItems
1.AksesorisCableband(M)
Cableband(L)
PlasticTube
Screwandnut
Cabletie
BukuManual
PVCtape
2.ClampkabelClampuntukTensionmemberTidakkendur
CableBandtidakkendur
3.RutekabelLoosetubeTidakadasmallbending(diameter>60)
kabelTidakterjepitatautersangkutjikatraydilepas
Tidakadasmallbending(diameter>60)
Tidakterjepitatautersangkutjikacovertraydibuka
5.RutePigtailpadaTrayRutemembentukhurufS
Tidakadasmallbending(diameter>60)
TidakTerjepitatautersangkutjikacovertraydibuka
Diperiksaoleh
(Sitemanager)
Catatan
pc
pc
Check
4.Rutekabeldalamtray
*Ceksisaaksesorisyangdiperlukan
untukinstalasikabelberikutnyadanuntuk
maintenance
InstallationCheckSheet
pcs
pcs
pcs
sets
pcs
6.9.4 INSTALLATION CHECK SHEET: TC-SM-144
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 67 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
6.10 LIST OF ASSEMBLY UNIT DESIGNATOR (1/6)
AKABEL&PENYAMBUNGAN
1DC-OF-SM-12D
PengadaandanpemasanganKabelDuctFiberOptik
SingleMode12coreG652D(termasukperijinan
PEMDA,PU,Warga)
meter
2DC-OF-SM-24DIdem24coremeter
3DC-OF-SM-48DIdem48coremeter
4DC-OF-SM-96DIdem96coremeter
5DC-OF-SM-144DIdem144coremeter
6DC-OF-SM-288DIdem288coremeter
7DC-OF-SM-432DIdem432coremeter
8DC-OF-SM-960DIdem960coremeter
9AC-OF-SM-12D
PengadaandanpemasanganKabelUdaraFiber
OptikSingleMode12coreG652D(termasuk
perijinanPEMDA,PU,Warga)
meter
10AC-OF-SM-24DIdem24coremeter
11AC-OF-SM-48DIdem48coremeter
12AC-OF-SM-96DIdem96coremeter
13DC-OF-SM-12C
PengadaandanpemasanganKabelDuctFiberOptik
SingleMode12coreG655C(termasukperijinan
PEMDA,PU,Warga)
meter
14DC-OF-SM-24CIdem24coremeter
15DC-OF-SM-48CIdem48coremeter
16DC-OF-SM-96CIdem96coremeter
17AC-OF-SM-12C
PengadaandanpemasanganKabelUdaraFiber
OptikSingleMode12coreG655C(termasuk
perijinanPEMDA,PU,Warga)
meter
18AC-OF-SM-24CIdem24coremeter
19AC-OF-SM-48CIdem48coremeter
20AC-OF-SM-96CIdem96coremeter
21DC-OF-SM-8-SC
PengadaandanpemasanganKabelDuctFiberOptik
SingleMode8coreG652D,"Easytosplit"
(termasukperijinanPEMDA,PU,Warga)
meter
22DC-OF-SM-12-SCIdem12Coremeter
23DC-OF-SM-24-SCIdem24Coremeter
24AC-OF-SM-8-SC
PengadaandanpemasanganKabelUdaraFiber
OptikSingleMode8coreG652D,"Easytosplit"
(termasukperijinanPEMDA,PU,Warga)
meter
25AC-OF-SM-12-SCIdem12Coremeter
26AC-OF-SM-24-SCIdem24Coremeter
27SC-OF-SM-24
Pengadaandanpemasanganalatsambung(cabang/
lurus)untukFiberOptikkapasitas12-24core
pcs
28SC-OF-SM-48Idem12-48corepcs
29SC-OF-SM-96Idem12-96corepcs
30SC-OF-SM-144Idem12-144corepcs
31SC-OF-SM-288Idem12-288corepcs
32OS-SM-1Eks
PenyambunganKabelOptikSingleModekap1core
dengancarafusionsplice
core
33OS-SM-6
PenyambunganKabelOptikSingleModekap6core
dengancarafusionsplice
pcs
34OS-SM-12Idemkap12corepcs
35OS-SM-24Idemkap24corepcs
36OS-SM-48Idemkap48corepcs
37OS-SM-96Idemkap96corepcs
38OS-SM-144Idemkap144corepcs
39OS-SM-288Idemkap288corepcs
40AB-OF-SM-2D
PengadaandanpemasanganAirBlownCableOptik,
SingleMode2core,G652D(termasukperijinan
PEMDA,PU,Warga)
meter
41AB-OF-SM-4DIdem4coremeter
42AB-OF-SM-8DIdem8coremeter
43AB-OF-SM-12DIdem12coremeter
44AB-OF-SM-24DIdem24coremeter
45AB-OF-SM-48DIdem48coremeter
46AB-OF-SM-72DIdem72coremeter
47AB-OF-SM-96DIdem96coremeter
48AB-OF-SM-144DIdem144coremeter
49GC-OF-SM-1D
PengadaandanpemasanganDropCableFODuct
/underground1CoreSingleMode,G.657
meter
50GC-OF-SM-2Didem2core
51HC-OF-SM-1D
PengadaandanpemasanganDropCableFOatas
tanah/aerial1CoreSingleMode,G.657
meter
52HC-OF-SM-2Didem2coremeter
53IC-OF-SM-1D
PengadaandanpemasanganIndoorCableFOSingle
Mode1core,G.657
meter
54IC-OF-SM-2DIdem2coremeter
KETERANGANNODESIGNATORURAIANPEKERJAANSATUAN
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 68 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
6.10 LIST OF ASSEMBLY UNIT DESIGNATOR (2/6)
55PC-SC-2-BI
Patchcord2meter,BendInsensitive(SC/APCTo
SC/UPC)dariRosetkeONT,G.657
pcs
56PC-SC-5-BI
Patchcord5meter,BendInsensitive(SC/APCTo
SC/UPC)dariRosetkeONT,G.657
pcs
57PC-SC-2Patchcord2meter,(SC/APCToSC/APC),G.657pcs
58PC-SC-5Patchcord5meter(SC/APCToSC/APC),G.657pcs
59PC-SC-10Patchcord10meter(SC/APCToSC/APC),G.657pcs
60PC-SC-20Patchcord20meter(SC/APCToSC/APC),G.657pcs
61PC-FC-20Patchcord20meter(FC/APCToFC/APC),G.657pcs
62PC-SC-30Patchcord30meter(SC/APCToSC/APC),G.657pcs
63PC-FC-30Patchcord30meter(FC/APCToFC/APC),G.657pcs
64PC-SC-40Patchcord40meter(SC/APCToSC/APC),G.657pcs
65PC-FC-40Patchcord40meter(FC/APCToFC/APC),G.657pcs
66PC-SC-2Patchcord2meter,(SC/UPCToSC/UPC),G.657pcs
67PC-SC-5Patchcord5meter(SC/UPCToSC/UPC),G.657pcs
68PC-SC-10Patchcord10meter(SC/UPCToSC/UPC),G.657pcs
69PC-SC-20Patchcord20meter(FC/UPCToFC/UPC),G.657pcs
70PC-FC-20Patchcord20meter(SC/UPCToSC/UPC),G.657pcs
71PC-SC-30Patchcord20meter(FC/UPCToFC/UPC),G.657pcs
72PC-FC-30Patchcord30meter(SC/UPCToSC/UPC),G.657pcs
73PC-SC-40Patchcord40meter(FC/UPCToFC/UPC),G.657pcs
74PC-FC-40Patchcord40meter(SC/UPCToSC/UPC),G.657pcs
75PC-FC-40Patchcord40meter(FC/UPCToFC/UPC),G.657pcs
76ODC-C-144Splitter
PengadaandanpemasangankabinetODC(Outdoor)
kap144coredenganspaceuntuksplitermodular
termasukmaterialadaptorSC/UPC,pigtail,pondasi
berlapiskeramik,lantaikerja,patokpengaman(5
buah),berikutpelabelan
pcs
77ODC-C-288Splitter
PengadaandanpemasangankabinetODC(Outdoor)
kap288coredenganspaceuntuksplitermodular
termasukmaterialadaptorSC/UPC,pigtail,pondasi
berlapiskeramik,lantaikerja,patokpengaman(5
buah),berikutpelabelan
pcs
78ODC-C-576Splitter
PengadaandanpemasangankabinetODC(Outdoor)
kap576coredenganspaceuntuksplitermodular
termasukmaterialadaptorSC/UPC,pigtail,pondasi
berlapiskeramik,lantaikerja,patokpengaman(5
buah),berikutpelabelan
pcs
79ODC-C-48Splitter
PengadaandanpemasanganODC-Pole(Outdoor)
withspaceforpassivespliter,adaptorSC/UPCkap
48core,berikutpelabelan
pcs
80ODP-CU-8
PengadaandanpemasanganODPtypeClosure
UndergroundKap8corewithspaceforsplitter,
AdapterSC/UPC
pcs
81ODP-CU-16idem16corepcs
82ODP-CA-8
PengadaandanpemasanganODPtypeClosure
AerialKap8coreberikutspacepasivespliter(1:8),
adapterSC/UPC,berikutpelabelan
pcs
83ODP-CA-16
PengadaandanpemasanganODPtypeClosure
AerialKap16coreberikutspace2pasivespliter
(1:8),adapterSC/UPC,berikutpelabelan
pcs
84ODP-A-8
PengadaandanpemasanganODPtypeIndoor/wall
Kap8coreberikutspacepasivespliter(1:8),adapter
SC/UPC,berikutpelabelan
pcs
85ODP-A-16
PengadaandanpemasanganODPtypeIndoor/wall
Kap16coreberikutspace2pasivespliter(1:8),
adapterSC/UPC,berikutpelabelan
pcs
86ODP-A-24
PengadaandanpemasanganODPtypeIndoor/wall
Kap24coreberikutspace3pasivespliter(1:8),
adapterSC/UPC,berikutpelabelan
pcs
87ODP-A-48
PengadaandanpemasanganODPtypeIndoor/wall
Kap48coreberikutspace6pasivespliter(1:8),
adapterSC/UPC,berikutpelabelan
pcs
88ODP-PL-8
PengadaandanpemasanganODP(Pilar)kap8
coretermasukpigtail,berikutspace1splitter(1:8),
pelabelan.
pcs
89ODP-PL-16
PengadaandanpemasanganODP(Pilar)kap16
coretermasukpigtail,berikutspace2splitter(1:8),
pelabelan.
pcs
KETERANGANNODESIGNATORURAIANPEKERJAANSATUAN
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 69 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
6.10 LIST OF ASSEMBLY UNIT DESIGNATOR (3/6)
90TC-SM-12
PengadaandanPemasanganOTBtermasuk
terminasidanpenyambungankabeloptikSingle
modekap12coresertaAdapter(SCConnector),
pigtaildanprotectionsleevepadacassette/box
pcs
91TC-SM-24Idem24corepcs
92TC-SM-48Idem48corepcs
93TC-SM-72Idem72corepcs
94TC-SM-96Idem96corepcs
95TC-SM-144Idem144corepcs
96RS-IN-SC-1P
PemasangandanterminasiRoset/IndoorOptical
OutletwithSCAdaptor-kap1portberikutpigtail
pcs
97RS-IN-SC-2Pidem2portpcs
98RS-IN-SC-4Pidem4portpcs
99TC-MK-SC-1P
RosetOptikModularKeystone(Ditanamditembok)
denganSCAdaptorkap1port
unit
100TC-MK-SC-2Pidem2portunit
101TC-MK-SC-4Pidem4portunit
102PS-1-2-ODC
PengadaandanpemasanganPassiveSplitter1:2,
typemodular,forODC,termasukpigtail
pcs
103PS-1-4-ODCIdem,1:4pcs
104PS-1-8-ODCIdem,1:8pcs
105PS-1-16-ODCIdem,1:16pcs
106PS-1-32-ODCIdem,1:32pcs
107PS-1-2-ODP
PengadaandanpemasanganPassiveSplitter1:2,
typePLC/Modular,forODP,termasukadaptor
pcs
108PS-1-4-ODPIdem,1:4pcs
109PS-1-8-ODPIdem,1:8pcs
110PS-1-16-ODPIdem,1:16pcs
111PS-1-32-ODPIdem,1:32pcs
112PS-2-2-ODC
PengadaandanpemasanganPassiveSplitter2:2,
typemodular,forODC,termasukpigtail
pcs
113PS-2-4-ODCIdem,2:4pcs
114PS-2-8-ODCIdem,2:8pcs
115PS-2-16-ODCIdem,2:16pcs
116PS-2-32-ODCIdem,2:32pcs
117PS-2-2-ODP
PengadaandanpemasanganPassiveSplitter2:2,
typePLC/Modular,forODP,termasukadaptor
pcs
118PS-2-4-ODPIdem,2:4pcs
119PS-2-8-ODPIdem,2:8pcs
120PS-2-16-ODPIdem,2:16pcs
121PS-2-32-ODPIdem,2:32pcs
122SITACODCAkuisisiLahanSITACODCNode
123PU-S7.0-140
PengadaandanPemasanganTiangBesi7meter,
berikutcat&corpondasidanassesories-kekuatan
tarik140kg
pcs
124PU-S9.0-140
PengadaandanPemasanganTiangBesi9meter,
berikutcat&cordanassesories-kekuatantarik140
kg
pcs
125PU-C9.0-300
PengadaandanPemasanganTiangBeton9meter,
berikutassesories
126GU-GPengadaandanPemasanganTemberangTarikpcs
127PU-SB-7.0-140
Pengadaandanpemasangantemberangsokong7
meter,kekuatantarik140kg
pcs
128PU-ASAsesoristiangeksistingset
129GB-G1
PengadaandanPemasanganGrounding1titikrod
padaODP/kotakpembagidenganmaks3ohm
pcs
130GB-G3
PengadaandanPemasanganGrounding3titikrod
padaODCdenganmaks1ohm
pcs
131GroundingdiEksisting
PengadaandanPemasanganmaterialGroundingdi
lokasigedungeksistingdengancaraintegrasi
pcs
132TC-XX-ODC
PengaddaandanPemasanganRisePipeuntuk
pengamankabeloptikkeODCPole/titiknaikKU
diamater1panjang3meter
pcs
133TC-OF-R-19
Pengadaandanpemasanganrakkabel19inchuntuk
FiberOptikClosedRack,2,2Mtr
pcs
134FLEX-PIPE
PengadaandanpemasanganFlexiblepipe(pipa
spiral)ukuran1.5inchtermasukaksesoris.
meter
KETERANGANNODESIGNATORURAIANPEKERJAANSATUAN
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 70 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
135PP-OF-IN
PengadaandanPemasanganPipeProtectorIndoor
Cable(PVCWhite)HighImpactConduit20mm
meter
136PP-OF-OUT
PengadaandanPemasanganPipeProtector
OutdoorCable(PVCBlack)HighImpactConduit20
mm
meter
137TC-OF-DC-10
PengadaandanpemasanganDuctCableuntuk
RouteKabelmenujuRoset,10x20mm
meter
138TC-OF-DC-20idem20x40mmmeter
139TC-OF-CR-100
PengadaandanpemasanganTrayCable,Lebar100
mmtebal5mmAlumuniumdisesuaikankebutuhan
meter
140TC-OF-CR-200idem200mmmeter
141TC-OF-CR-300idem300mmmeter
142DD-S3-1
PengadaandanpemasanganPipaBesiDiameter
Dalam100mmdanketebalanpipa3,65mmuntuk
crossing1pipa
meter
143DD-S3-2
PengadaandanpemasanganPipabesidiameter
dalam100mmdanketebalanpipa3,65mmuntuk
crossing2pipa
meter
144DD-S3-3
PengadaandanpemasanganPipabesidiameter
dalam100mmdanketebalanpipa3,65mmuntuk
crossing3pipa
meter
145DD-V4-1
PengadandanPemasanganPipaDuctdengan
pengecorandiameterdalam100mm,ketebalan4
mm,1pipa
meter
146DD-V4-2Idem,2pipameter
147DD-V5-1
PemasanganPipaDuctdenganpasirdia100mm,1
pipa(crossing)
meter
148DD-V5-2Idem,2pipameter
149DD-DA-S1
PengadaandanpemasanganpipaDuctmenempel
padajembatanmenggunakanPipaGalvanis
diamenterdalam100mm,tebal3,65mm,1pipa
meter
150DD-BSS-S1
PengadaandanpemasanganpipaDuctpada
jembatandenganmenempelmenggunakanPipabesi
Galv1pipa(Parit)
meter
151DD-BTS-S1
PengadaandanpemasanganPipaDuctdengan
penguatsendiri1pipa
meter
152DD-BTS-S2
PengadaandanpemasanganPipaDuctdengan
penguatsendiri2pipa
meter
153HB-PS-1
PengadaandanpemasanganPipaDuctdengan
systemgantung1pipabentangs/d40meter
meter
154HB-PS-2
PengadaandanpemasanganPipaDuctdengan
systemgantung2pipabentanglebih40meter
meter
155DD-BMR
BoringpadaLintasanKeretaApimenggunakan2
pipa
track
156DC-SD-1
PengadaandanPemasangan1Subduct27/32mm
padapolonganrouteDuct
meter
157DC-SD-3
PengadaandanPemasangan3Subduct27/32mm
padapolonganrouteDuct
meter
158DC-SD-1Big
PengadaandanPemasangan1SubductBigpada
polonganrouteDuct
meter
159DC-SD-2Big
PengadaandanPemasangan2SubductBigpada
polonganrouteDuct
meter
160DCD-PVC-1
PembuatanDuctCableDistribusidiameterpipaPVC
2incAW1pipa
meter
161DCD-PVC-2idem2pipameter
162DCD-PVC-4idem4pipameter
163DD-BM-1
PemasanganPipaDuctdengancaraboringmanual
/mesin1pipa
meter
164DD-BM-2Idem2pipameter
165DD-BM-HDPE-1
Boringmanual/mesinuntukHDPE/MicroDuct
diameterdalam33mm1pipakedalaman1,5meter
meter
166DD-BM-HDPE-2Idem,2pipameter
167DD-HDPE-1
PengadaandanPemasangan1pipaHDPE/HDPE
BIGuntukkabelFO,IncludeSoketHDPE
meter
168DD-HDPE-2Idem2pipa
169DD-ROD
PembersihanpadarouteDuctyangkosong/Rodding
DuctExisting.
meter
170DD-RV-1PerbaikanRouteDuct/HDPE,1pipa.meter
KETERANGANNODESIGNATORURAIANPEKERJAANSATUAN
6.10 LIST OF ASSEMBLY UNIT DESIGNATOR (4/6)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 71 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
6.10 LIST OF ASSEMBLY UNIT DESIGNATOR (5/6)
171DD-RV-CONCRETE
RelocatedanExspandPipainCounterWallbyBobok
Concrete
m3
172BC-TR-0.4
Galian,Pengurugankembalidanperbaikankembali,
pengisianpasir,deekstendantandarutekabeltanah
dantempatsambungkedalaman0.4meter
meter
173BC-TR-0.6
Galian,Pengurugankembalidanperbaikankembali,
pengisianpasir,deekstendantandarutekabeltanah
dantempatsambungkedalaman0.6meter
meter
174BC-TR-5
Galian,Pengurugankembalidanperbaikankembali,
pengisianpasir,deekstendantandarutekabeltanah
dantempatsambungkedalaman1,5meter
meter
175BD-SK
PembobokandanperbaikanDindinguntuklubang
SparingKabel
Titik
176BP-IC
PembobokandanperbaikanPlafonuntukrouteIndoor
Cable
Titik
177SMD-ABS-2A
PengadaandanpemasanganAlatSambungMicro
Ductcabang/lurus2cabang,termasukconnector,gas
block&endcap
pcs
178SMD-ABS-3Aidem3cabangpcs
179SMD-ABS-4Aidem4cabangpcs
180DD-MDDI-1A
PengadaandanPemasangan5/3.5mmMicroDuct,
DirectInstall,1way,untukAirBlownkabelFO
termasukconnector
meter
181DD-MDDI-2AIdem2waymeter
182DD-MDDI-4AIdem4waymeter
183DD-MDDI-7AIdem7waymeter
184DD-MDDI-12AIdem12waymeter
185DD-MDDI-19AIdem19waymeter
186DD-MDDI-24AIdem24waymeter
187DD-MDDI-1B
PengadaandanPemasangan10/8mmMicroDuct,
DirectInstall,1way,untukAirBlownkabelFO
termasukconnector
meter
188DD-MDDI-2BIdem2waymeter
189DD-MDDI-4BIdem4waymeter
190DD-MDDI-7BIdem7waymeter
191DD-MDDI-1C
PengadaandanPemasangan12/10mmMicroDuct,
DirectInstall,1way,untukAirBlownkabelFO
termasukconnector
meter
192DD-MDDI-2CIdem2waymeter
193DD-MDDI-4CIdem4waymeter
194DD-MDDI-7CIdem7waymeter
195DD-MDDB-1A
PengadaandanPemasangan5/3.5mmMicroDuct,
DirectBuried,1way,untukAirBlownkabelFO
termasukconnector
meter
196DD-MDDB-2AIdem2waymeter
197DD-MDDB-4AIdem4waymeter
198DD-MDDB-7AIdem7waymeter
199DD-MDDB-12AIdem12waymeter
200DD-MDDB-19AIdem19waymeter
201DD-MDDB-24AIdem24waymeter
202DD-MDDB-1B
PengadaandanPemasangan10/8mmMicroDuct,
DirectBuried,1way,untukAirBlownkabelFO
termasukconnector
meter
203DD-MDDB-2BIdem2waymeter
204DD-MDDB-4BIdem4waymeter
205DD-MDDB-7BIdem7waymeter
206DD-MDDB-1C
PengadaandanPemasangan12/10mmMicroDuct,
DirectBuried,1way,untukAirBlownkabelFO
termasukconnector
meter
207DD-MDDB-2CIdem2waymeter
208DD-MDDB-4CIdem4waymeter
209DD-MDDB-7CIdem7waymeter
210GB-K-A1GambarKertaskalkirukuranA1HardCopy&Softlbr
211GB-L-A1GambarKertaslighdrukukuranA1lbr
212MH-HIS5PembuatanManholeLurusTypeHIS5pcs
213MH-HIS5TPembuatanManholeTypeHIS5Tpcs
214MH-HIIS7PembuatanManholeTypeHIIS7pcs
215MH-HH1PembuatanHandholeTypeHH1pcs
216MH-HH2PembuatanHandholeTypeHH2pcs
217MH-CAPeninggianTutupManhole/Handholepcs
218MH-MODModifikasiManhole/Handhole(sesuailuasan)m3
219MH-RSInstalasistrukturrakdalammanholeyangada.kg
220HH-PIT-60
PembuatanHHukurandiameterdalam(PXLXT=
60x40x60)corbeton1:2:3
pcs
221HH-PIT-40
PembuatanHHukurandiameterdalam(PXLXT=
40x40x40)corbeton1:2:3
pcs
KETERANGANNODESIGNATORURAIANPEKERJAANSATUAN
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 72 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
6.10 LIST OF ASSEMBLY UNIT DESIGNATOR (6/6)
222HH-PIT-Portable
PengadaandanpemasanganHHPitPortable
besertaaksesorisnya
pcs
BNEWITEM
newDD-HDPE-Big
PengadaandanPemasangan1pipaHDPE/HDPE
BIGuntukkabelFO,IncludeSoketHDPE
meterUNTUK288
newDD-V4-4
PengadandanPemasanganPipaDuctdengan
pengecorandiameterdalam100mm,ketebalan4
mm,4pipa
meterOK
newHH-80
PembuatanHHukurandiameterdalam(PXLXT=
80x80x80)corbeton1:2:3
pcs
new
CableTray/Ladder(Plastic)40x40mmBerikut
Assesories
meter
new
CableTray/Ladder(Plastic)16x16mmBerikut
Assesories
meter
newBC-PP
PengaddaandanPemasanganRisePipeBesiuntuk
pengamankabeloptik/titiknaikKUdanGrounding
diamater1,5inchpanjang3meter
pcsOK
newODC-HRB-180pcsOK
newODC-HRB-240pcsOK
newODC-HRB-420pcsOK
newODP-HRB-16pcsOK
newODP-HRB-32pcsOK
newODP-SSW-8
PengadaandanpemasanganODPtypeClosure
Aerial(SSW)Kap8coreberikutspacepasivespliter
(1:8),adapterSC/UPC,berikutpelabelan
pcs
newODP-PW-8
PengadaandanpemasanganODPtypeOudoor/wall
Kap8coreberikutspacepasivespliter(1:8),adapter
SC/UPC,berikutpelabelan
pcsOK
newODP-PW-16
PengadaandanpemasanganODPtypeOudoor/wall
Kap16coreberikutspace2pasivespliter(1:8),
adapterSC/UPC,berikutpelabelan
pcsOK
newODP-PW-BR-16pcs
newODP-PL-BR-16pcs
newPengukuranCableExistingCore
KETERANGANNODESIGNATORURAIANPEKERJAANSATUAN
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 73 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 74 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 75 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
Civil Work
FOC Laying Work
FOC Joint Work
FOC Termination Work
OTDR Measurement
Total Loss Measurement
by LS/OPM
Construction
Work
UT (PAT) UT
Pass
Fail
Work Flow to Test-Com(Internal Commissioning Test) and UT (PAT)
1. High Loss Event Detection
by OTDR 1.55um for;
1) Feeder Segment,
2) Distribution Segment
2. Fiber Length Measurement
Test-Com
(Internal Test)
(for optical test on Fiber)
Preparation of OPM Test Form
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 76 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
1 2 3 4 5 6 7 8 9 1011 12
1 2 3 4 5 6 7 8 9 1011 12
1:8 splitter
1
2
3
4
5
6
7
8
1:8 splitter
1
2
3
4
5
6
7
8
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
1:4splitter
OTB ODC ODP
No.1
ODP
No.2
Feeder
Cable
Distribution
Cable 1:8
splitter
Port#.1
1:4 splitter
Port#.1
Splitter
#.1
Port#.1
Splitter#.1
Splitter#.2
Port#.1 Port#.1
Feeder
Cable
Distribution
Cable
Typical System Cofiguration between OTB and ODP
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 77 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
Definition of Segment
OTB
fo
Feeder
1:4 splitter
ODC
fo
Distribution
1:8 splitter
ODP
fo
Drop
Rosette ONT
BIF
patchcord
OLT
Feeder Segment Distribution Segment
(Drop Segment)
Splice
SC/UPC connector
Overall Segment (OTB - ODP)
Bi-directional OTDR Measurement shall
be done upon request by TELKOM
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 78 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
Policy of Test for Optial Measurement
• OTDR ; detect partially harmful waveform =only 1.55um (sensitive for fiber bend)
• LS/OPM ; for guarantee the final performance of the line
1) Feeder Segment
1-1) Measurment by OTDR with one-way to detect partially harmful event
(Bi-directional Measurement shall be done for Segment A - Segment A' upon request by TELKOM.)
1-2) Measurment by LS/OPM
2) Distribution Segment
2-1) Measurment by OTDR from ODC to ODP splitter input (one-way)
(because Handy OTDR cannot measure over 1:8 splitter)
2-2) Measurment by LS/OPM
3) Drop Segment
Measurment by LS/OPM
(Drop Segment cannot be measured by OTDR because drop cable length is <100m)
4) End to End ; Overall Section
Measurment only by LS/OPM
(because Handy OTDR cannot measure over 1:8 splitter)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 79 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
Optical
Light
Source
NEW
Patch-cord
Optical
Power
Meter
NEW Battery
KALIBRASI (Input Power Measurement)
Method of Measurement
Leave the Light Source 5 ~ 10 min. to
make the input power (Pi) stable after
switch on.
• Check Pi three (3) times at least
• Max.Pi - Min.Pi < 0.1dB
• Average Pi
Ex. Good Bad
1st - 8.20dBm -8.20dBm
2nd -8.18dBm -8.18dBm
3rd -8.22dBm -8. 07dBm
Ave -8. 20dBm
Pi = 8.20dB
DO NOT
TAKE OUT
Optical
Light Source
Optical
Power Meter
TAKE OUT
(OPM SIDE)
Prior to LS/OPM Measurement, the INPUT
POWER (Pi) shall be measured and recorded.
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 80 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
OTB
fo
Feeder 1:4 splitter
ODC
Segment A'
Segment A' cannot be measured by
OTDR because 4-OTDR signal overlap
in this segment.
Optical performance of this segment
is guaranteed by Test Report of splitter
module and measurment
of Segment A by LS/OPM
OTB
fo
Feeder 1:4 splitter
ODC
Segment A
Segment A'
OTDR
Optical Power
Meter
OTDR@1550nm
LS/OPM
@1310nm & 1550nm
Patchcord is
not needed for
measurment
Optial Light
Source
Segment A
1.1 Feeder Segment
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 81 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
1.2 Distribution Segment-1 (SCPT and SSW; ODP installed)
fo
Distribution
1:8 splitter
ODP
Segment B
ODC
Segment B'
OTDR@1550nm
LS/OPM
@1310nm & 1550nm
Segment B' cannot measure by OTDR
because 8-OTDR signal overlap in this
segment.
Optical performance of this segment is
guaranteed by Test Report of splitter
module and measurment of Segment
B by LS/OPM.
fo
Distribution
1:8 splitter
ODP
Segment B
ODC
Bi-directional mesurement by ODR is not
possible because Handy OTDR cannot
measure over 1:8 splitter.
OTDR
Optial Light
Source
Optical Power
Meter
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 82 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
1.3 Distribution Segment-2
SCPT/SSW CADANGAN or,
SSW; ODP not installed, only cable installed
fo
Distribution
Segment B
ODC OTDR@1550nm
LS/OPM
@1310nm&1550nmfo
Distribution
Segment B
ODC
temporarily splice pigtail to end
of fiber
OTDR
Optial Light
Source
Optical Power
Meter
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 83 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
1.4 Drop Segment
ODP
fo
Drop
Rosette
Segment C
LS/OPM
@1310nm&1550nm
Drop segment cannot be measured by
OTDR because drop cable length is
<100m.
Optial Light
Source
Optical Power
Meter
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 84 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
1.5 End to End Overall (SCPT and SSW; ODP installed)
OTB
fo
Feeder
1:4 splitter
ODC
fo
Distribution
1:8 splitter
ODP
fo
Drop
Rosette
Segment A Segment B Segment CSegment D
LS/OPM
@1310nm & 1550nm
Note:
Overall segment cannot be measured by OTDR
because splitter is included in the line.
Optial Light
Source Optical
Power Meter
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 85 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
1.6 Calculation of Attenuation Limit (LS/OPM Test)
Segment Calculation of Attenuation Limit Remarks
1. Feeder Cable Segment
- 1310nm A-F13= {0.35dB/km x .. Km} + {0.1dB x (No. of Splice)} +
{0.25dB x (No. of Connector)}
A-F13: Attenuation Limit of Feeder
Cable at 1310nm
- 1550nm A-F15= {0.215dB/km x .. Km} + {0.1dB x (No. of Splice)} +
{0.25dB x (No. of Connector)}
A-F15: Attenuation Limit of Feeder
Cable at 1550nm
2. Distribution Cable Segment
- 1310nm A-D13= {0.35dB/km x .. Km} + {0.1dB x (No. of Splice)} +
{0.25dB x (No. of Connector)}
A-D13: Attenuation Limit of
Distribution Cable at 1310nm
- 1550nm A-D15= {0.215dB/km x .. Km} + {0.1dB x (No. of Splice)} +
{0.25dB x (No. of Connector)}
A-D15: Attenuation Limit of
Distribution Cable at 1550nm
3. Drop Cable Segment
- 1310nm A-DR13= {0.35dB/km x .. Km} + {0.25dB x (No. of
Connector)}
A-DR13: Attenuation Limit of
Distribution Cable at 1310nm
- 1550nm A-DR15= {0.215dB/km x .. Km} + {0.25dB x (No. of
Connector)}
A-DR15: Attenuation Limit of
Distribution Cable at 1550nm
4. End to End/Overall Section
- 1310nm A-EE13= [A-F13] + 7.5dB (Splitter 1x4) + [D-F13] + 11.0dB
(Splitter 1x8) + [A-DR13]
A-EE13: Overall Attenuation of End
to End at 1310nm
- 1550nm A-EE15= [A-F15] + 7.5dB (Splitter 1x4) + [D-F15] + 11.0dB
(Splitter 1x8) + [A-DR15]
A-EE15: Overall Attenuation of End
to End at 1550nm
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 86 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 87 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
Form # Name From / To
Ia / Ib Total Loss Measurement 1310nm / 1550nm
Subsystem: Oerall Segment (OTB-ODC-ODP)
From: OTB ①①①①
To: ODP ⑤⑤⑤⑤
IIa / IIb Seg.A(OTB-ODC_splitter) Loss Measurement 1310nm/ 1550nm
Subsystem: Feeder Segment (OTB-ODC) without splitter
From: OTB ①①①①
To: ODC ②②②②
IIc / IId Seg.A(OTB-ODC_splitter) Loss Measurement 1310nm/ 1550nm
Subsystem: Feeder Segment (OTB-ODC) with passive splitter 1:4
From: OTB ①①①①
To:ODC ④④④④
IIIa / IIIb Seg.B(ODC-ODP) Loss Measurement 1310nm/1550nm
Subsystem: Segment B (ODC - ODP)
From: ODC ④④④④
To: ODP ⑤⑤⑤⑤
2.1 APPLICATION OF MEASUREMENT FORMS
Form Ia / Ib
(Overall Segment)
OTB
Feeder
Cable
ODC
Distribution
Cable
1:8
splitter
ODP No.X
Port#.1
1:4 splitter
Port#.1
Splitter
#.1
Port#.1
Splitter
#.1
Port#.1
Form IIa / IIb
(Feeder Segment / Seg.A)
Form IIIa / IIIb
(Distribution Segment / Seg.B)
Form IIc / IId
(Feeder Segment / Seg.A)
1 2
3
4
6
5
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 88 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
2.1.1 FORM I a/I b: Overall Segment (OTB-ODC-ODP)
2 6
Distribution Cable Core No.
to be terminated at ODP
NOTE:
1) Input in accordance with
the site information, condition
2) Input when measurement
3
5
1
OTB
Feeder
Cable
ODC
Distribution
Cable
1:8
splitter
ODP No.X
Port#.1
1:4 splitter
Port#.1
Splitter#.1
Port#.1
Splitter#.1
Port#.1
OVERALL SEGMENT
1 2
3
4
6
5
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 89 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
2.1.2 FORM II a/II b: Feeder Segment (OTB-ODC) without splitter
OTB
Feeder
Cable
ODC
Distribution
Cable
1:8
splitter
ODP No.X
Port#.1
1:4 splitter
Port#.1
Splitter#.1
Port#.1
Splitter#.1
Port#.1
FEEDER SEGMENT
1 2
3
4
6
5
NOTE:
1) Input in accordance with the
site information, condition
2) Input when measurementInput Tray No.
1 2
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 90 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
2.1.3 FORM II c/II d: Feeder Segment (OTB-ODC) with 1:4 Passive Splitter
OTB
Feeder
Cable
ODC
Distribution
Cable
1:8
splitter
ODP No.X
Port#.1
1:4 splitter
Port#.1
Splitter#.1
Port#.1
Splitter#.1
Port#.1
FEEDER SEGMENT with Splitter
1 2
3
4
6
5
1 3 4
NOTE:
1) Input in accordance with the
site information, condition
2) Input when measurement
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 91 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
2.1.4 FORM III a/III b: Distribution Segment (ODC-ODP)
OTB
Feeder
Cable
ODC
Distribution
Cable
1:8
splitter
ODP No.X
Port#.1
1:4 splitter
Port#.1
Splitter#.1
Port#.1
Splitter#.1
Port#.1
DISTRIBUTION SEGMENT
1 2
3
4
6
5
6 3 4
5
NOTE:
1) Input in accordance with the
site information, condition
2) Input when measurement
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 92 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
2.2 MEASUREMENT FORMS (File: UT-Form Measurement -r2.2.xls)
Note:
1) Forms provided hereunder is "r-2.3a", which is the
latest version as of 28 June, 2013.
2) It is to request users to confirm the latest version to JF
DJAFa Consortium before use Forms.
3) Use Forms of Excel format for submission purpose.
4) In case if the form is not enough (e.g. more than 5 ODP
(1:8 Splitter) are exist in one distribution cable), the
related "Worksheet of Excel" (e.g. Form I and III) shall
be duplicated/copied.
5) Do not incert any Line/Raw in the form so as not to
alter the calculation formula in the sheet.
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 93 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
2.2.1 FORM I a: Overall Segment (OTB-ODC-ODP) @ 1310nm
FORM:Ia
PTTELEKOMUNIKASIINDONESIA
SubSistem:OVERALLSEGMENT(OTB-ODC-ODP)
ODCNo.CAPACITYE00˚˚˚˚00'00"
CABLENo.WAVELENGTH
RESULT
No.PortNo.Pin(dB)Pout(dB)Pout-Pin(dB)PASS/FAILSE
CoreNo.1-PASS
2-PASS
ODPNo.3-PASS
4-PASS
5-PASS
SplitterNo.6-PASS
7-PASS
8-PASS
CoreNo.1-PASS
2-PASS
ODPNo.3-PASS
4-PASS
5-PASS
SplitterNo.6-PASS
7-PASS
8-PASS
CoreNo.1-PASS
2-PASS
ODPNo.3-PASS
4-PASS
5-PASS
SplitterNo.6-PASS
7-PASS
8-PASS
CoreNo.1-PASS
2-PASS
ODPNo.3-PASS
4-PASS
5-PASS
SplitterNo.6-PASS
7-PASS
8-PASS
Catatan:PowerMeterdigunakanuntuktestpelurusankabel
*)TotalLoss=(Cablelengthx0,35dB+Connectorx0.25dB+Splitter1:4x7.25dB+Splitter1:8x10.38dB+Splicex0.1dB)
CALCULATIONOFLOSSBUDGET:
Unit
Attenuation
Splitter-.1Splitter-.2Splitter-.3Splitter-.4
1.CABLELENGTH(km)0.35----
2.No.ofSPLICE(pcs)0.1
3.No.ofCONNECTOR(pcs)0.25
4.SPLITTER1:4(1pc)7.25
5.SPLITTER1:8(1pc)10.38
0.000.000.000.00
FEEDER
DISTRIBUTIO
N
DISTRIBUTIO
N
DISTRIBUTIO
N
DISTRIBUTIO
N
CABLELENGTH(km):
Note:CABLELENGTHofOTDRIndication
OverallLossMeasurement1310nm
DATEOFMEASUREMENT:
DAERASTONAMA
LOKASI
ATTENUATIONLIMITATION(dB)
-
-
ODC
PORTNo.
LOSS
BUDGET
-
-
00˚˚˚˚00'00"
00˚˚˚˚00'00"
00˚˚˚˚00'00"
00˚˚˚˚00'00"
00˚˚˚˚00'00"
00˚˚˚˚00'00"
ODPCOORDINATES
00˚˚˚˚00'00"
Measurementtools:PowerMeter
Specification/limitation:dB(Cablelengthx0.35dB+Connectorx0.25dB+Splitter1:4x7.25dB+Splitter1:8x10.38dB+Splicex0.1dB)
NoofCores1310nm
REMARKS
FEEDERCABLEDISTRIBUTIONCABLE
00˚˚˚˚00'00"
ODPATTENUATION(dB)
NoofCores
OTBPortNo.
COORDINATESS00˚˚˚˚00'00"
CABLENo.
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 94 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
2.2.2 FORM I b: Overall Segment (OTB-ODC-ODP) @ 1550nm
FORM:Ib
PTTELEKOMUNIKASIINDONESIA
SubSistem:OVERALLSEGMENT(OTB-ODC-ODP)
ODCNo.CAPACITYE00˚˚˚˚00'00"
CABLENo.WAVELENGTH
ODPPortNo.ODPSpecificationlimitationAttenuation(dB)ResultRemarks
RESULT
No.PortNo.Pin(dB)Pout(dB)Pout-Pin(dB)PASS/FAILSE
CoreNo.1-PASS
2-PASS
ODPNo.3-PASS
4-PASS
5-PASS
SplitterNo.6-PASS
7-PASS
8-PASS
CoreNo.1-PASS
2-PASS
ODPNo.3-PASS
4-PASS
5-PASS
SplitterNo.6-PASS
7-PASS
8-PASS
CoreNo.1-PASS
2-PASS
ODPNo.3-PASS
4-PASS
5-PASS
SplitterNo.6-PASS
7-PASS
8-PASS
CoreNo.1-PASS
2-PASS
ODPNo.3-PASS
4-PASS
5-PASS
SplitterNo.6-PASS
7-PASS
8-PASS
*)TotalLoss=(Cablelengthx0,215dB+Connectorx0.25dB+Splitter1:4x7.25dB+Splitter1:8x10.38dB+Splicex0.1dB)
CALCULATI
ONOF
ATTENUATI
ONLIMIT:
Unit
Attenuation
Splitter-.1Splitter-.2Splitter-.3Splitter-.4
0.2150000
2.No.ofSPLICE(pcs)0.1
3.No.ofCONNECTOR(pcs)0.25
4.SPLITTER1:4(1pc)7.25
5.SPLITTER1:8(1pc)10.38
0.000.000.000.00
FEEDER
DISTRIBUTIO
N
DISTRIBUTIO
N
DISTRIBUTIO
N
DISTRIBUTIO
N
CABLELENGTH(km):
Note:CABLELENGTHofOTDRIndication
TotalLossMeasurement1550nm
DATEOFMEASUREMENT:
DAERASTO
ATTENUATION(dB)ODPCOORDINATES
FEEDERCABLE
COORDINATESS00˚˚˚˚00'00"
CABLENo.
1.CABLELENGTH(km)
ATTENUATIONLIMITATION(dB)
ODC
PORTNo.
LOSS
BUDGET
NAMA
LOKASI
NoofCores
00˚˚˚˚00'00"
00˚˚˚˚00'00"
00˚˚˚˚00'00"
00˚˚˚˚00'00"
DISTRIBUTIONCABLENoofCores
OTBPortNo.
Specification/limitation:dB(Cablelengthx0.215dB+Connectorx0.25dB+Splitter1:4x7.25dB+Splitter1:8x10.38dB+Splicex0.1dB)
ODP
00˚˚˚˚00'00"
00˚˚˚˚00'00"
00˚˚˚˚00'00"
00˚˚˚˚00'00"
1550nm
REMARKS
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 95 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
2.2.3 FORM II a: Feeder Segment (OTB-ODC) without splitter @ 1310nm
FORM:IIa
PTTELEKOMUNIKASIINDONESIA
WAVELENGTH
CAPACITY
OTBRESULT
PORTNo.TrayNo.PortNo.Pin(dB)Pout(dB)Pout-Pin(dB)PASS/FAIL
11-PASS
22-PASS
33-PASS
44-PASS
55-PASS
66-PASS
77-PASS
88-PASS
99-PASS
1010-PASS
1111-PASS
1212-PASS
131-PASS
142-PASS
153-PASS
164-PASS
175-PASS
186-PASS
197-PASS
208-PASS
219-PASS
2210-PASS
2311-PASS
2412-PASS
251-PASS
262-PASS
273-PASS
284-PASS
295-PASS
306-PASS
317-PASS
328-PASS
339-PASS
3410-PASS
3511-PASS
3612-PASS
371-PASS
382-PASS
393-PASS
404-PASS
415-PASS
426-PASS
437-PASS
448-PASS
459-PASS
4610-PASS
4711-PASS
4812-PASS
Catatan:PowerMeterdigunakanuntuktestpelurusankabel
*)TotalLoss=(Cablelengthx0,35dB+Connectorx0.25dB+Splicex0.1dB)
CALCULATIONOFATTENUATIONLIMIT:
UnitAttenuationODC
1.CABLELENGTH(km)0.35-
2.No.ofSPLICE(pcs)0.1
3.No.ofCONNECTOR(pcs)0.25
0.00
FEEDER
CABLELENGTH(km)
Note:CABLELENGTHofOTDRIndication
NAMA
LOKASI
Seg.A(OTB-ODC_splitter)LossMeasurement1310nm
SubSistem:FEEDERSEGMENT(OTB-ODC)WITHOUTSPLITTERDATEOFMEASUREMENT:
DAERASTO
Measurementtools:PowerMeter
ODC
NAME/TYPE
1310nmNo.ofCores
ODCCOORDINATESS00˚˚˚˚00'00"E00˚˚˚˚00'00"
Specification/limitation:dB(Cablelengthx0.35dB+Connectorx0.25dB+Splitter1:4x7.25dB+Splicex0.1dB)
ODCATTNUATION(dB)
ATTENUATIONLIMITATION(dB)
REMARKS
FEEDERCABLE
CABLENo.
No.LOSS
BUDGET
-
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 96 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
2.2.4 FORM II b: Feeder Segment (OTB-ODC) without splitter @ 1550nm
FORM:IIb
PTTELEKOMUNIKASIINDONESIA
WAVELENGTH
CAPACITY
OTBRESULT
PORTNo.TrayNo.PortNo.Pin(dB)Pout(dB)Pout-Pin(dB)PASS/FAIL
11-PASS
22-PASS
33-PASS
44-PASS
55-PASS
66-PASS
77-PASS
88-PASS
99-PASS
1010-PASS
1111-PASS
1212-PASS
131-PASS
142-PASS
153-PASS
164-PASS
175-PASS
186-PASS
197-PASS
208-PASS
219-PASS
2210-PASS
2311-PASS
2412-PASS
251-PASS
262-PASS
273-PASS
284-PASS
295-PASS
306-PASS
317-PASS
328-PASS
339-PASS
3410-PASS
3511-PASS
3612-PASS
371-PASS
382-PASS
393-PASS
404-PASS
415-PASS
426-PASS
437-PASS
448-PASS
459-PASS
4610-PASS
4711-PASS
4812-PASS
Catatan:PowerMeterdigunakanuntuktestpelurusankabel
*)TotalLoss=(Cablelengthx0,215dB+Connectorx0.25dB+Splicex0.1dB)
CALCULATIONOFATTENUATIONLIMIT:
UnitAttenuationODC
1.CABLELENGTH(km)0.215-
2.No.ofSPLICE(pcs)0.1
3.No.ofCONNECTOR(pcs)0.25
0.00
FEEDER
CABLELENGTH(km)
Note:CABLELENGTHofOTDRIndication
NAMA
LOKASI
Seg.A(OTB-ODC_splitter)LossMeasurement1550nm
SubSistem:FEEDERSEGMENT(OTB-ODC)WITHOUTSPLITTERDATEOFMEASUREMENT:
DAERASTO
Measurementtools:PowerMeter
ODC
NAME/TYPE
1550nmNo.ofCores
ODCCOORDINATESS00˚˚˚˚00'00"E00˚˚˚˚00'00"
Specification/limitation:dB(Cablelengthx0.215dB+Connectorx0.25dB+Splitter1:4x7.25dB+Splicex0.1dB)
ODCATTNUATION(dB)
ATTENUATIONLIMITATION(dB)
REMARKS
FEEDER
CABLE
CABLENo.
No.LOSS
BUDGET
-
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 97 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
2.2.5 FORM II c: Feeder Segment (OTB-ODC) with 1:4 Passive Splitter @ 1310nm
FORM:IIc
PTTELEKOMUNIKASIINDONESIA
WAVELENGTH
CAPACITY
OTBRESULT
PORTNo.SplitterPortNo.Pin(dB)Pout(dB)Pout-Pin(dB)PASS/FAIL
11-PASS
22-PASS
33-PASS
44-PASS
51-PASS
62-PASS
73-PASS
84-PASS
91-PASS
102-PASS
113-PASS
124-PASS
131-PASS
142-PASS
153-PASS
164-PASS
171-PASS
182-PASS
193-PASS
204-PASS
211-PASS
222-PASS
233-PASS
244-PASS
251-PASS
262-PASS
273-PASS
284-PASS
291-PASS
302-PASS
313-PASS
324-PASS
331-PASS
342-PASS
353-PASS
364-PASS
371-PASS
382-PASS
393-PASS
404-PASS
411-PASS
422-PASS
433-PASS
444-PASS
451-PASS
462-PASS
473-PASS
484-PASS
Catatan:PowerMeterdigunakanuntuktestpelurusankabel
*)TotalLoss=(Cablelengthx0,35dB+Connectorx0.25dB+Splitter1:4x7.25dB+Splicex0.1dB)
CALCULATIONOFATTENUATIONLIMIT:
UnitAttenuationODC
1.CABLELENGTH(km)0.35-
2.No.ofSPLICE(pcs)0.1
3.No.ofCONNECTOR(pcs)0.25
4.SPLITTER1:4(1pc)7.25
0.00
FEEDER
CABLELENGTH(km)
Note:CABLELENGTHofOTDRIndication
Seg.A(OTB-ODC_splitter)LossMeasurement1310nm
SubSistem:FEEDERSEGMENT(OTB-ODC)WITHPASSIVESPLITTER1:4DATEOFMEASUREMENT:
DAERASTO
No.
ODCATTNUATION(dB)
ATTENUATIONLIMITATION(dB)
1
2
3
4
5
6
7
9
10
11
12
LOSS
BUDGET
-
1310nm
REMARKS
8
Specification/limitation:dB(Cablelengthx0.35dB+Connectorx0.25dB+Splitter1:4x7.25dB+Splicex0.1dB)
No.ofCores
ODCCOORDINATESS00˚˚˚˚00'00"E00˚˚˚˚00'00"
Measurementtools:PowerMeter
FEEDERCABLE
CABLENo.
ODC
NAMA
LOKASI
NAME/TYPE
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 98 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
2.2.6 FORM II d: Feeder Segment (OTB-ODC) with 1:4 Passive Splitter @ 1550nm
FORM:IId
PTTELEKOMUNIKASIINDONESIA
WAVELENGTH
CAPACITY
OTBRESULT
PORTNo.SplitterPortNo.Pin(dB)Pout(dB)Pout-Pin(dB)PASS/FAIL
11-PASS
22-PASS
33-PASS
44-PASS
51-PASS
62-PASS
73-PASS
84-PASS
91-PASS
102-PASS
113-PASS
124-PASS
131-PASS
142-PASS
153-PASS
164-PASS
171-PASS
182-PASS
193-PASS
204-PASS
211-PASS
222-PASS
233-PASS
244-PASS
251-PASS
262-PASS
273-PASS
284-PASS
291-PASS
302-PASS
313-PASS
324-PASS
331-PASS
342-PASS
353-PASS
364-PASS
371-PASS
382-PASS
393-PASS
404-PASS
411-PASS
422-PASS
433-PASS
444-PASS
451-PASS
462-PASS
473-PASS
484-PASS
Catatan:PowerMeterdigunakanuntuktestpelurusankabel
*)TotalLoss=(Cablelengthx0,215dB+Connectorx0.25dB+Splitter1:4x7.25dB+Splicex0.1dB)
CALCULATIONOFATTENUATIONLIMIT:
UnitAttenuationODC
1.CABLELENGTH(km)0.215-
2.No.ofSPLICE(pcs)0.1
3.No.ofCONNECTOR(pcs)0.25
4.SPLITTER1:4(1pc)7.25
0.00
FEEDER
CABLELENGTH(km)
Note:CABLELENGTHofOTDRIndication
Seg.A(OTB-ODC_splitter)LossMeasurement1550nm
SubSistem:FEEDERSEGMENT(OTB-ODC)WITHPASSIVESPLITTERDATEOFMEASUREMENT:
DAERASTO
No.
ODCATTNUATION(dB)
ATTENUATIONLIMITATION(dB)
6
1
2
3
4
5
12
7
8
9
10
11
-
ODC
NAMA
LOKASI
NAME/TYPE
Specification/limitation:dB(Cablelengthx0.215dB+Connectorx0.25dB+Splitter1:4x7.25dB+Splicex0.1dB)
No.ofCores
ODCCOORDINATESS00˚˚˚˚00'00"E00˚˚˚˚00'00"
Measurementtools:PowerMeter
1550nm
REMARKS
FEEDER
CABLE
CABLENo.
LOSS
BUDGET
Handbook for ftth osp v1.0
Handbook for ftth osp v1.0
Handbook for ftth osp v1.0

Contenu connexe

Tendances

Fttx planning and design
Fttx planning and designFttx planning and design
Fttx planning and designAhmed Hamdy
 
FTTH Basics and Network Design.pdf
FTTH Basics and Network Design.pdfFTTH Basics and Network Design.pdf
FTTH Basics and Network Design.pdfHisham Hasan
 
Huawei GPON Fundamentals
Huawei GPON FundamentalsHuawei GPON Fundamentals
Huawei GPON Fundamentalsibrahimnabil17
 
Modul 1 overview ft tx
Modul 1 overview ft txModul 1 overview ft tx
Modul 1 overview ft txSherly Toresia
 
Real Fibre optic FTTH FTTX network design, engineering & planning software fo...
Real Fibre optic FTTH FTTX network design, engineering & planning software fo...Real Fibre optic FTTH FTTX network design, engineering & planning software fo...
Real Fibre optic FTTH FTTX network design, engineering & planning software fo...van den Dool Dick
 
Fttx fiber-count-planning-calculation
Fttx fiber-count-planning-calculationFttx fiber-count-planning-calculation
Fttx fiber-count-planning-calculationKarthik Govin
 
Passive infrastructure of FTTH networks: an overview
Passive infrastructure of FTTH networks: an overviewPassive infrastructure of FTTH networks: an overview
Passive infrastructure of FTTH networks: an overviewLuc De Heyn
 
Gpon Fundamentals
Gpon FundamentalsGpon Fundamentals
Gpon Fundamentalsmansoor_gr8
 
ftth mnc vision march 2019.pptx
ftth mnc vision  march 2019.pptxftth mnc vision  march 2019.pptx
ftth mnc vision march 2019.pptxDandiErlangga2
 
Gponfundamentals 130805074507-phpapp02
Gponfundamentals 130805074507-phpapp02Gponfundamentals 130805074507-phpapp02
Gponfundamentals 130805074507-phpapp02morris otieno
 
Convergence Access Networks Challenge Gpon
Convergence Access Networks Challenge GponConvergence Access Networks Challenge Gpon
Convergence Access Networks Challenge GponQasim Khan
 
Modul 5 guidance hld & survey lapangan ft tx
Modul 5 guidance hld & survey lapangan ft txModul 5 guidance hld & survey lapangan ft tx
Modul 5 guidance hld & survey lapangan ft txSherly Toresia
 
Huawei OLT Ma5600 & 5608t GPON feature glance
Huawei OLT Ma5600 & 5608t GPON feature glanceHuawei OLT Ma5600 & 5608t GPON feature glance
Huawei OLT Ma5600 & 5608t GPON feature glanceSayed Qaisar Shah
 
Passive Optical Networks - PON: Customer Case Study, Design, Implementation a...
Passive Optical Networks - PON: Customer Case Study, Design, Implementation a...Passive Optical Networks - PON: Customer Case Study, Design, Implementation a...
Passive Optical Networks - PON: Customer Case Study, Design, Implementation a...Bruno Teixeira
 
Ont, olt and mdu in gpon technology
Ont, olt and mdu in gpon technologyOnt, olt and mdu in gpon technology
Ont, olt and mdu in gpon technologyHuanetwork
 

Tendances (20)

Fttx planning and design
Fttx planning and designFttx planning and design
Fttx planning and design
 
FTTH Basics and Network Design.pdf
FTTH Basics and Network Design.pdfFTTH Basics and Network Design.pdf
FTTH Basics and Network Design.pdf
 
Huawei GPON Fundamentals
Huawei GPON FundamentalsHuawei GPON Fundamentals
Huawei GPON Fundamentals
 
Fttx arcitectures
Fttx arcitecturesFttx arcitectures
Fttx arcitectures
 
Modul 1 overview ft tx
Modul 1 overview ft txModul 1 overview ft tx
Modul 1 overview ft tx
 
Fttx
FttxFttx
Fttx
 
Real Fibre optic FTTH FTTX network design, engineering & planning software fo...
Real Fibre optic FTTH FTTX network design, engineering & planning software fo...Real Fibre optic FTTH FTTX network design, engineering & planning software fo...
Real Fibre optic FTTH FTTX network design, engineering & planning software fo...
 
Fttx fiber-count-planning-calculation
Fttx fiber-count-planning-calculationFttx fiber-count-planning-calculation
Fttx fiber-count-planning-calculation
 
Passive infrastructure of FTTH networks: an overview
Passive infrastructure of FTTH networks: an overviewPassive infrastructure of FTTH networks: an overview
Passive infrastructure of FTTH networks: an overview
 
Gpon Fundamentals
Gpon FundamentalsGpon Fundamentals
Gpon Fundamentals
 
ftth mnc vision march 2019.pptx
ftth mnc vision  march 2019.pptxftth mnc vision  march 2019.pptx
ftth mnc vision march 2019.pptx
 
Gpon fundamentals
Gpon fundamentals Gpon fundamentals
Gpon fundamentals
 
Gponfundamentals 130805074507-phpapp02
Gponfundamentals 130805074507-phpapp02Gponfundamentals 130805074507-phpapp02
Gponfundamentals 130805074507-phpapp02
 
FTTH Basics
FTTH BasicsFTTH Basics
FTTH Basics
 
Gpon fundamentals
Gpon fundamentalsGpon fundamentals
Gpon fundamentals
 
Convergence Access Networks Challenge Gpon
Convergence Access Networks Challenge GponConvergence Access Networks Challenge Gpon
Convergence Access Networks Challenge Gpon
 
Modul 5 guidance hld & survey lapangan ft tx
Modul 5 guidance hld & survey lapangan ft txModul 5 guidance hld & survey lapangan ft tx
Modul 5 guidance hld & survey lapangan ft tx
 
Huawei OLT Ma5600 & 5608t GPON feature glance
Huawei OLT Ma5600 & 5608t GPON feature glanceHuawei OLT Ma5600 & 5608t GPON feature glance
Huawei OLT Ma5600 & 5608t GPON feature glance
 
Passive Optical Networks - PON: Customer Case Study, Design, Implementation a...
Passive Optical Networks - PON: Customer Case Study, Design, Implementation a...Passive Optical Networks - PON: Customer Case Study, Design, Implementation a...
Passive Optical Networks - PON: Customer Case Study, Design, Implementation a...
 
Ont, olt and mdu in gpon technology
Ont, olt and mdu in gpon technologyOnt, olt and mdu in gpon technology
Ont, olt and mdu in gpon technology
 

Similaire à Handbook for ftth osp v1.0

PT Eigen Network - Network Planning & Overview
PT Eigen Network - Network Planning & OverviewPT Eigen Network - Network Planning & Overview
PT Eigen Network - Network Planning & OverviewEM Archieve
 
B 1 b-12 f0371b(standard operation procedure)
B 1 b-12 f0371b(standard operation procedure)B 1 b-12 f0371b(standard operation procedure)
B 1 b-12 f0371b(standard operation procedure)Chikal II
 
B 1 b-12 f0371b(standard operation procedure)
B 1 b-12 f0371b(standard operation procedure)B 1 b-12 f0371b(standard operation procedure)
B 1 b-12 f0371b(standard operation procedure)Chikal II
 
PLNOG16: Planowanie sieci FTTx z wykorzystaniem technik T-WDM, Adam Grodecki
PLNOG16: Planowanie sieci FTTx z wykorzystaniem technik T-WDM, Adam GrodeckiPLNOG16: Planowanie sieci FTTx z wykorzystaniem technik T-WDM, Adam Grodecki
PLNOG16: Planowanie sieci FTTx z wykorzystaniem technik T-WDM, Adam GrodeckiPROIDEA
 
Technical Proposal - Longhaul Backbone Project
Technical Proposal - Longhaul Backbone ProjectTechnical Proposal - Longhaul Backbone Project
Technical Proposal - Longhaul Backbone ProjectKhurram Shafique
 
Hcd 70 Split Waveguide
Hcd 70 Split WaveguideHcd 70 Split Waveguide
Hcd 70 Split Waveguideguest36ea6a77
 
Design of Satellite Based Solution for Indonesian Far and Outermost Islands
Design of Satellite Based Solution for Indonesian Far and Outermost Islands Design of Satellite Based Solution for Indonesian Far and Outermost Islands
Design of Satellite Based Solution for Indonesian Far and Outermost Islands Uun Ainurrofiq (Fiq)
 
Design a Low Power Flip-Flop Based on a Signal Feed-Through Scheme
Design a Low Power Flip-Flop Based on a Signal Feed-Through SchemeDesign a Low Power Flip-Flop Based on a Signal Feed-Through Scheme
Design a Low Power Flip-Flop Based on a Signal Feed-Through SchemeIRJET Journal
 
GSM_UMTS_Single_RAN_operation_and_Maintenance_training_Volume_2.pptx
GSM_UMTS_Single_RAN_operation_and_Maintenance_training_Volume_2.pptxGSM_UMTS_Single_RAN_operation_and_Maintenance_training_Volume_2.pptx
GSM_UMTS_Single_RAN_operation_and_Maintenance_training_Volume_2.pptxhussenbelew
 
Tank700kl 150530040421-lva1-app6891
Tank700kl 150530040421-lva1-app6891Tank700kl 150530040421-lva1-app6891
Tank700kl 150530040421-lva1-app6891Tanmay Majhi
 
ELECTRICAL DESIGN ENGINEER - RESUME
ELECTRICAL DESIGN ENGINEER -  RESUMEELECTRICAL DESIGN ENGINEER -  RESUME
ELECTRICAL DESIGN ENGINEER - RESUMEVEERABHARATHI MUNI
 
PCB Design and Layout - Checklist of What You Need Before You Start
PCB Design and Layout - Checklist of What You Need Before You StartPCB Design and Layout - Checklist of What You Need Before You Start
PCB Design and Layout - Checklist of What You Need Before You StartEpec Engineered Technologies
 
Advances in EM Simulations
Advances in EM SimulationsAdvances in EM Simulations
Advances in EM SimulationsAltair
 
Analysis of FinFET and CNTFET based HybridCMOS Full Adder Circuit
Analysis of FinFET and CNTFET based HybridCMOS Full Adder CircuitAnalysis of FinFET and CNTFET based HybridCMOS Full Adder Circuit
Analysis of FinFET and CNTFET based HybridCMOS Full Adder CircuitIRJET Journal
 
Fiber optics catalogue_ver2.01
Fiber optics catalogue_ver2.01Fiber optics catalogue_ver2.01
Fiber optics catalogue_ver2.01Eric Yang
 
Total Turnkey DAS: A Path to Ensure Rapid Business Growth and Career Success
Total Turnkey DAS: A Path to Ensure Rapid Business Growth and Career SuccessTotal Turnkey DAS: A Path to Ensure Rapid Business Growth and Career Success
Total Turnkey DAS: A Path to Ensure Rapid Business Growth and Career Successtelecom-wiring
 

Similaire à Handbook for ftth osp v1.0 (20)

PT Eigen Network - Network Planning & Overview
PT Eigen Network - Network Planning & OverviewPT Eigen Network - Network Planning & Overview
PT Eigen Network - Network Planning & Overview
 
B 1 b-12 f0371b(standard operation procedure)
B 1 b-12 f0371b(standard operation procedure)B 1 b-12 f0371b(standard operation procedure)
B 1 b-12 f0371b(standard operation procedure)
 
B 1 b-12 f0371b(standard operation procedure)
B 1 b-12 f0371b(standard operation procedure)B 1 b-12 f0371b(standard operation procedure)
B 1 b-12 f0371b(standard operation procedure)
 
PLNOG16: Planowanie sieci FTTx z wykorzystaniem technik T-WDM, Adam Grodecki
PLNOG16: Planowanie sieci FTTx z wykorzystaniem technik T-WDM, Adam GrodeckiPLNOG16: Planowanie sieci FTTx z wykorzystaniem technik T-WDM, Adam Grodecki
PLNOG16: Planowanie sieci FTTx z wykorzystaniem technik T-WDM, Adam Grodecki
 
Technical Proposal - Longhaul Backbone Project
Technical Proposal - Longhaul Backbone ProjectTechnical Proposal - Longhaul Backbone Project
Technical Proposal - Longhaul Backbone Project
 
Hcd 70 Split Waveguide
Hcd 70 Split WaveguideHcd 70 Split Waveguide
Hcd 70 Split Waveguide
 
Gpon Network
Gpon NetworkGpon Network
Gpon Network
 
Gpon Network
Gpon NetworkGpon Network
Gpon Network
 
Design of Satellite Based Solution for Indonesian Far and Outermost Islands
Design of Satellite Based Solution for Indonesian Far and Outermost Islands Design of Satellite Based Solution for Indonesian Far and Outermost Islands
Design of Satellite Based Solution for Indonesian Far and Outermost Islands
 
Design a Low Power Flip-Flop Based on a Signal Feed-Through Scheme
Design a Low Power Flip-Flop Based on a Signal Feed-Through SchemeDesign a Low Power Flip-Flop Based on a Signal Feed-Through Scheme
Design a Low Power Flip-Flop Based on a Signal Feed-Through Scheme
 
GSM_UMTS_Single_RAN_operation_and_Maintenance_training_Volume_2.pptx
GSM_UMTS_Single_RAN_operation_and_Maintenance_training_Volume_2.pptxGSM_UMTS_Single_RAN_operation_and_Maintenance_training_Volume_2.pptx
GSM_UMTS_Single_RAN_operation_and_Maintenance_training_Volume_2.pptx
 
Tank700kl 150530040421-lva1-app6891
Tank700kl 150530040421-lva1-app6891Tank700kl 150530040421-lva1-app6891
Tank700kl 150530040421-lva1-app6891
 
Tank 700 kl
Tank 700 klTank 700 kl
Tank 700 kl
 
ELECTRICAL DESIGN ENGINEER - RESUME
ELECTRICAL DESIGN ENGINEER -  RESUMEELECTRICAL DESIGN ENGINEER -  RESUME
ELECTRICAL DESIGN ENGINEER - RESUME
 
PCB Design and Layout - Checklist of What You Need Before You Start
PCB Design and Layout - Checklist of What You Need Before You StartPCB Design and Layout - Checklist of What You Need Before You Start
PCB Design and Layout - Checklist of What You Need Before You Start
 
PON design considerations for FTTH FTTx
PON design considerations for FTTH FTTxPON design considerations for FTTH FTTx
PON design considerations for FTTH FTTx
 
Advances in EM Simulations
Advances in EM SimulationsAdvances in EM Simulations
Advances in EM Simulations
 
Analysis of FinFET and CNTFET based HybridCMOS Full Adder Circuit
Analysis of FinFET and CNTFET based HybridCMOS Full Adder CircuitAnalysis of FinFET and CNTFET based HybridCMOS Full Adder Circuit
Analysis of FinFET and CNTFET based HybridCMOS Full Adder Circuit
 
Fiber optics catalogue_ver2.01
Fiber optics catalogue_ver2.01Fiber optics catalogue_ver2.01
Fiber optics catalogue_ver2.01
 
Total Turnkey DAS: A Path to Ensure Rapid Business Growth and Career Success
Total Turnkey DAS: A Path to Ensure Rapid Business Growth and Career SuccessTotal Turnkey DAS: A Path to Ensure Rapid Business Growth and Career Success
Total Turnkey DAS: A Path to Ensure Rapid Business Growth and Career Success
 

Dernier

Editorial design Magazine design project.pdf
Editorial design Magazine design project.pdfEditorial design Magazine design project.pdf
Editorial design Magazine design project.pdftbatkhuu1
 
2-tool presenthdbdbdbdbddhdhddation.pptx
2-tool presenthdbdbdbdbddhdhddation.pptx2-tool presenthdbdbdbdbddhdhddation.pptx
2-tool presenthdbdbdbdbddhdhddation.pptxsuhanimunjal27
 
Design Inspiration for College by Slidesgo.pptx
Design Inspiration for College by Slidesgo.pptxDesign Inspiration for College by Slidesgo.pptx
Design Inspiration for College by Slidesgo.pptxTusharBahuguna2
 
💫✅jodhpur 24×7 BEST GENUINE PERSON LOW PRICE CALL GIRL SERVICE FULL SATISFACT...
💫✅jodhpur 24×7 BEST GENUINE PERSON LOW PRICE CALL GIRL SERVICE FULL SATISFACT...💫✅jodhpur 24×7 BEST GENUINE PERSON LOW PRICE CALL GIRL SERVICE FULL SATISFACT...
💫✅jodhpur 24×7 BEST GENUINE PERSON LOW PRICE CALL GIRL SERVICE FULL SATISFACT...sonalitrivedi431
 
infant assessment fdbbdbdddinal ppt.pptx
infant assessment fdbbdbdddinal ppt.pptxinfant assessment fdbbdbdddinal ppt.pptx
infant assessment fdbbdbdddinal ppt.pptxsuhanimunjal27
 
Booking open Available Pune Call Girls Nanded City 6297143586 Call Hot India...
Booking open Available Pune Call Girls Nanded City  6297143586 Call Hot India...Booking open Available Pune Call Girls Nanded City  6297143586 Call Hot India...
Booking open Available Pune Call Girls Nanded City 6297143586 Call Hot India...Call Girls in Nagpur High Profile
 
Call Girls Basavanagudi Just Call 👗 7737669865 👗 Top Class Call Girl Service ...
Call Girls Basavanagudi Just Call 👗 7737669865 👗 Top Class Call Girl Service ...Call Girls Basavanagudi Just Call 👗 7737669865 👗 Top Class Call Girl Service ...
Call Girls Basavanagudi Just Call 👗 7737669865 👗 Top Class Call Girl Service ...amitlee9823
 
Top Rated Pune Call Girls Saswad ⟟ 6297143586 ⟟ Call Me For Genuine Sex Serv...
Top Rated  Pune Call Girls Saswad ⟟ 6297143586 ⟟ Call Me For Genuine Sex Serv...Top Rated  Pune Call Girls Saswad ⟟ 6297143586 ⟟ Call Me For Genuine Sex Serv...
Top Rated Pune Call Girls Saswad ⟟ 6297143586 ⟟ Call Me For Genuine Sex Serv...Call Girls in Nagpur High Profile
 
Chapter 19_DDA_TOD Policy_First Draft 2012.pdf
Chapter 19_DDA_TOD Policy_First Draft 2012.pdfChapter 19_DDA_TOD Policy_First Draft 2012.pdf
Chapter 19_DDA_TOD Policy_First Draft 2012.pdfParomita Roy
 
The_Canvas_of_Creative_Mastery_Newsletter_April_2024_Version.pdf
The_Canvas_of_Creative_Mastery_Newsletter_April_2024_Version.pdfThe_Canvas_of_Creative_Mastery_Newsletter_April_2024_Version.pdf
The_Canvas_of_Creative_Mastery_Newsletter_April_2024_Version.pdfAmirYakdi
 
UI:UX Design and Empowerment Strategies for Underprivileged Transgender Indiv...
UI:UX Design and Empowerment Strategies for Underprivileged Transgender Indiv...UI:UX Design and Empowerment Strategies for Underprivileged Transgender Indiv...
UI:UX Design and Empowerment Strategies for Underprivileged Transgender Indiv...RitikaRoy32
 
Pooja 9892124323, Call girls Services and Mumbai Escort Service Near Hotel Hy...
Pooja 9892124323, Call girls Services and Mumbai Escort Service Near Hotel Hy...Pooja 9892124323, Call girls Services and Mumbai Escort Service Near Hotel Hy...
Pooja 9892124323, Call girls Services and Mumbai Escort Service Near Hotel Hy...Pooja Nehwal
 
call girls in Kaushambi (Ghaziabad) 🔝 >༒8448380779 🔝 genuine Escort Service 🔝...
call girls in Kaushambi (Ghaziabad) 🔝 >༒8448380779 🔝 genuine Escort Service 🔝...call girls in Kaushambi (Ghaziabad) 🔝 >༒8448380779 🔝 genuine Escort Service 🔝...
call girls in Kaushambi (Ghaziabad) 🔝 >༒8448380779 🔝 genuine Escort Service 🔝...Delhi Call girls
 
Jigani Call Girls Service: 🍓 7737669865 🍓 High Profile Model Escorts | Bangal...
Jigani Call Girls Service: 🍓 7737669865 🍓 High Profile Model Escorts | Bangal...Jigani Call Girls Service: 🍓 7737669865 🍓 High Profile Model Escorts | Bangal...
Jigani Call Girls Service: 🍓 7737669865 🍓 High Profile Model Escorts | Bangal...amitlee9823
 
VVIP CALL GIRLS Lucknow 💓 Lucknow < Renuka Sharma > 7877925207 Escorts Service
VVIP CALL GIRLS Lucknow 💓 Lucknow < Renuka Sharma > 7877925207 Escorts ServiceVVIP CALL GIRLS Lucknow 💓 Lucknow < Renuka Sharma > 7877925207 Escorts Service
VVIP CALL GIRLS Lucknow 💓 Lucknow < Renuka Sharma > 7877925207 Escorts Servicearoranaina404
 
Brookefield Call Girls: 🍓 7737669865 🍓 High Profile Model Escorts | Bangalore...
Brookefield Call Girls: 🍓 7737669865 🍓 High Profile Model Escorts | Bangalore...Brookefield Call Girls: 🍓 7737669865 🍓 High Profile Model Escorts | Bangalore...
Brookefield Call Girls: 🍓 7737669865 🍓 High Profile Model Escorts | Bangalore...amitlee9823
 
VIP Model Call Girls Kalyani Nagar ( Pune ) Call ON 8005736733 Starting From ...
VIP Model Call Girls Kalyani Nagar ( Pune ) Call ON 8005736733 Starting From ...VIP Model Call Girls Kalyani Nagar ( Pune ) Call ON 8005736733 Starting From ...
VIP Model Call Girls Kalyani Nagar ( Pune ) Call ON 8005736733 Starting From ...SUHANI PANDEY
 
call girls in Vasundhra (Ghaziabad) 🔝 >༒8448380779 🔝 genuine Escort Service 🔝...
call girls in Vasundhra (Ghaziabad) 🔝 >༒8448380779 🔝 genuine Escort Service 🔝...call girls in Vasundhra (Ghaziabad) 🔝 >༒8448380779 🔝 genuine Escort Service 🔝...
call girls in Vasundhra (Ghaziabad) 🔝 >༒8448380779 🔝 genuine Escort Service 🔝...Delhi Call girls
 
Call Girls in Kalkaji Delhi 8264348440 call girls ❤️
Call Girls in Kalkaji Delhi 8264348440 call girls ❤️Call Girls in Kalkaji Delhi 8264348440 call girls ❤️
Call Girls in Kalkaji Delhi 8264348440 call girls ❤️soniya singh
 

Dernier (20)

Editorial design Magazine design project.pdf
Editorial design Magazine design project.pdfEditorial design Magazine design project.pdf
Editorial design Magazine design project.pdf
 
2-tool presenthdbdbdbdbddhdhddation.pptx
2-tool presenthdbdbdbdbddhdhddation.pptx2-tool presenthdbdbdbdbddhdhddation.pptx
2-tool presenthdbdbdbdbddhdhddation.pptx
 
Design Inspiration for College by Slidesgo.pptx
Design Inspiration for College by Slidesgo.pptxDesign Inspiration for College by Slidesgo.pptx
Design Inspiration for College by Slidesgo.pptx
 
💫✅jodhpur 24×7 BEST GENUINE PERSON LOW PRICE CALL GIRL SERVICE FULL SATISFACT...
💫✅jodhpur 24×7 BEST GENUINE PERSON LOW PRICE CALL GIRL SERVICE FULL SATISFACT...💫✅jodhpur 24×7 BEST GENUINE PERSON LOW PRICE CALL GIRL SERVICE FULL SATISFACT...
💫✅jodhpur 24×7 BEST GENUINE PERSON LOW PRICE CALL GIRL SERVICE FULL SATISFACT...
 
infant assessment fdbbdbdddinal ppt.pptx
infant assessment fdbbdbdddinal ppt.pptxinfant assessment fdbbdbdddinal ppt.pptx
infant assessment fdbbdbdddinal ppt.pptx
 
Booking open Available Pune Call Girls Nanded City 6297143586 Call Hot India...
Booking open Available Pune Call Girls Nanded City  6297143586 Call Hot India...Booking open Available Pune Call Girls Nanded City  6297143586 Call Hot India...
Booking open Available Pune Call Girls Nanded City 6297143586 Call Hot India...
 
Call Girls Basavanagudi Just Call 👗 7737669865 👗 Top Class Call Girl Service ...
Call Girls Basavanagudi Just Call 👗 7737669865 👗 Top Class Call Girl Service ...Call Girls Basavanagudi Just Call 👗 7737669865 👗 Top Class Call Girl Service ...
Call Girls Basavanagudi Just Call 👗 7737669865 👗 Top Class Call Girl Service ...
 
Top Rated Pune Call Girls Saswad ⟟ 6297143586 ⟟ Call Me For Genuine Sex Serv...
Top Rated  Pune Call Girls Saswad ⟟ 6297143586 ⟟ Call Me For Genuine Sex Serv...Top Rated  Pune Call Girls Saswad ⟟ 6297143586 ⟟ Call Me For Genuine Sex Serv...
Top Rated Pune Call Girls Saswad ⟟ 6297143586 ⟟ Call Me For Genuine Sex Serv...
 
Chapter 19_DDA_TOD Policy_First Draft 2012.pdf
Chapter 19_DDA_TOD Policy_First Draft 2012.pdfChapter 19_DDA_TOD Policy_First Draft 2012.pdf
Chapter 19_DDA_TOD Policy_First Draft 2012.pdf
 
The_Canvas_of_Creative_Mastery_Newsletter_April_2024_Version.pdf
The_Canvas_of_Creative_Mastery_Newsletter_April_2024_Version.pdfThe_Canvas_of_Creative_Mastery_Newsletter_April_2024_Version.pdf
The_Canvas_of_Creative_Mastery_Newsletter_April_2024_Version.pdf
 
UI:UX Design and Empowerment Strategies for Underprivileged Transgender Indiv...
UI:UX Design and Empowerment Strategies for Underprivileged Transgender Indiv...UI:UX Design and Empowerment Strategies for Underprivileged Transgender Indiv...
UI:UX Design and Empowerment Strategies for Underprivileged Transgender Indiv...
 
Pooja 9892124323, Call girls Services and Mumbai Escort Service Near Hotel Hy...
Pooja 9892124323, Call girls Services and Mumbai Escort Service Near Hotel Hy...Pooja 9892124323, Call girls Services and Mumbai Escort Service Near Hotel Hy...
Pooja 9892124323, Call girls Services and Mumbai Escort Service Near Hotel Hy...
 
call girls in Kaushambi (Ghaziabad) 🔝 >༒8448380779 🔝 genuine Escort Service 🔝...
call girls in Kaushambi (Ghaziabad) 🔝 >༒8448380779 🔝 genuine Escort Service 🔝...call girls in Kaushambi (Ghaziabad) 🔝 >༒8448380779 🔝 genuine Escort Service 🔝...
call girls in Kaushambi (Ghaziabad) 🔝 >༒8448380779 🔝 genuine Escort Service 🔝...
 
Jigani Call Girls Service: 🍓 7737669865 🍓 High Profile Model Escorts | Bangal...
Jigani Call Girls Service: 🍓 7737669865 🍓 High Profile Model Escorts | Bangal...Jigani Call Girls Service: 🍓 7737669865 🍓 High Profile Model Escorts | Bangal...
Jigani Call Girls Service: 🍓 7737669865 🍓 High Profile Model Escorts | Bangal...
 
VVIP CALL GIRLS Lucknow 💓 Lucknow < Renuka Sharma > 7877925207 Escorts Service
VVIP CALL GIRLS Lucknow 💓 Lucknow < Renuka Sharma > 7877925207 Escorts ServiceVVIP CALL GIRLS Lucknow 💓 Lucknow < Renuka Sharma > 7877925207 Escorts Service
VVIP CALL GIRLS Lucknow 💓 Lucknow < Renuka Sharma > 7877925207 Escorts Service
 
Brookefield Call Girls: 🍓 7737669865 🍓 High Profile Model Escorts | Bangalore...
Brookefield Call Girls: 🍓 7737669865 🍓 High Profile Model Escorts | Bangalore...Brookefield Call Girls: 🍓 7737669865 🍓 High Profile Model Escorts | Bangalore...
Brookefield Call Girls: 🍓 7737669865 🍓 High Profile Model Escorts | Bangalore...
 
VIP Model Call Girls Kalyani Nagar ( Pune ) Call ON 8005736733 Starting From ...
VIP Model Call Girls Kalyani Nagar ( Pune ) Call ON 8005736733 Starting From ...VIP Model Call Girls Kalyani Nagar ( Pune ) Call ON 8005736733 Starting From ...
VIP Model Call Girls Kalyani Nagar ( Pune ) Call ON 8005736733 Starting From ...
 
call girls in Vasundhra (Ghaziabad) 🔝 >༒8448380779 🔝 genuine Escort Service 🔝...
call girls in Vasundhra (Ghaziabad) 🔝 >༒8448380779 🔝 genuine Escort Service 🔝...call girls in Vasundhra (Ghaziabad) 🔝 >༒8448380779 🔝 genuine Escort Service 🔝...
call girls in Vasundhra (Ghaziabad) 🔝 >༒8448380779 🔝 genuine Escort Service 🔝...
 
Call Girls in Kalkaji Delhi 8264348440 call girls ❤️
Call Girls in Kalkaji Delhi 8264348440 call girls ❤️Call Girls in Kalkaji Delhi 8264348440 call girls ❤️
Call Girls in Kalkaji Delhi 8264348440 call girls ❤️
 
Call Girls Service Mukherjee Nagar @9999965857 Delhi 🫦 No Advance VVIP 🍎 SER...
Call Girls Service Mukherjee Nagar @9999965857 Delhi 🫦 No Advance  VVIP 🍎 SER...Call Girls Service Mukherjee Nagar @9999965857 Delhi 🫦 No Advance  VVIP 🍎 SER...
Call Girls Service Mukherjee Nagar @9999965857 Delhi 🫦 No Advance VVIP 🍎 SER...
 

Handbook for ftth osp v1.0

  • 1. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 1 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N HANDBOOKHANDBOOKHANDBOOKHANDBOOK ForForForFor Outside PlantOutside PlantOutside PlantOutside Plant----Fiber to the HomeFiber to the HomeFiber to the HomeFiber to the Home (FTTH(FTTH(FTTH(FTTH----OSP)OSP)OSP)OSP) ForForForFor PT TELKOM INDONESIAPT TELKOM INDONESIAPT TELKOM INDONESIAPT TELKOM INDONESIA V 1.0V 1.0V 1.0V 1.0 <REFERENCE<REFERENCE<REFERENCE<REFERENCE ffffor DESIGN,or DESIGN,or DESIGN,or DESIGN, WORKWORKWORKWORK IMPLEMENTATION & TESTING>IMPLEMENTATION & TESTING>IMPLEMENTATION & TESTING>IMPLEMENTATION & TESTING> (June 2013)(June 2013)(June 2013)(June 2013)
  • 2. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 2 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N Contents PART-I DESIGN & INSTALLATION ........................................................................ 4 FTTH-OSP DESIGN PRINCIPLES .......................................................................... 5 MATERIALS FOR FTTH-OSP (STO - ODP) .......................................................................... 7 MATERIALS FOR FTTH-OSP (HRB: Hign-Rise Building) ......................................................... 8 1. FEEDER CABLE DESIGN .. . ... 11 1.1 Google Map .......................................... 11 1.2 Skema Kabel Feeder .. ............... . 12 1.3 PetaLokasi Duct & Kabel Feeder . .. . 15 1.4 Sample Design of Feeder Cable Network . . ............. 15 1.5 Core Assignment Diagram . . . .. 19 1.6 General Concept for Feeder Cable Design . .. ............ 22 2. DISTRIBUTION CABLE DESIGN . 25 2.1 Google Map .. ... 25 2.2 Skema Kabel Distribusi .. 25 2.3 Sample Design of Distribution Cable Network . ............ 28 2.4 Branching ODP .. .......... 32 2.5 Duct Usage for Distribution Network & Drop-core Installation (Underground) .......................... 33 3. GENERAL CONCEPT FOR DISTRIBUTION CABLE DESIGN ............. 34 3.1 Duct / Buried Section . ............... 34 3.2 Aerial Section .. ............................ 37 4. CABLE RACK / OTB RACK IN STO BUILDING .. . 41
  • 3. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 3 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 5. HIGH-RISE BUILDING (HRB) DESIGN ......................................................................... 42 5.1 Materials for HRB Solution ........................................... 42 5.2 Design Concept for HRB Solution .. ............... .. 43 5.3 Type of ODC for High-Rise-Building . .. .. 44 5.4 Example of Cable Tray/Trunking . . ............. 45 5.5 Sample Design: Skema Distribusi . . . .. 46 5.6 Sample Design: Peta Lokasi Distribusi . .. ............ 47 6. REFERENCE . 50 6.1 Pondasi ODC-C-144 Splitter .. ... 51 6.2 Pondasi ODC-C-288 Splitter .. ... 52 6.3 Pondasi ODP Pedestal & HH-PIT-60 . .............. 53 6.4 HH-1: Dimensi Dalam (P=1700 x L=1250 x T=1300) ... .. .......... 54 6.5 HH-2: Dimensi Dalam (P=1200 x L=600 x T=1300) .............................................................. 55 6.6 HH-80: Dimensi Dalam (P=800 x L=800 x T=800) .............................................................. 56 6.7 Installation of ODP Wall ............................................................................ 57 6.8 Form for Core Assignment Diagram ............................................................................ 59 6.9 Installation Check Sheet ............................................................................ 63 6.10 List of Assembly Unit Designator ............................................................................ 67 PART-II ACCEPTANCE TESTING ........................................................................ 73 1. TEST PROCEDURE ................................ 74 2. OPM MEASUREMENT ......................................................................... 86 2.1 Application of Measurement Forms . ............... 87 2.2 Measurement Forms .. ............................ 92
  • 4. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 4 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
  • 5. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 5 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N FTTH-OSP DESIGN PRINCIPLES (1) 1. FTTH OSP Design Work (Feeder & Distribusion) shall be carried out in accordance with the frame of this document. 2. LINK BUDGET 1) Descriptions in the Contract: The Design shall ensure the FTTH OSP System Power Budget of the GPON OLT to ONU (in the configuration of 1:4 Splitter at ODC and 1:8 Splitter at ODP) shall be 28dB (including the margin of 3dB). 2) Applicable Power Budget in the Project: Contract Requirement: 28dB - 3dB (Margin) = 25dB (ITU-T G.652D @ Wave Length 1310nm=0.35dB/km) Requirement by KBB: 25dB - 2dB = 23dB (including 2dB as an Additional Margin due to an incidental increment of the loss in OSP during an operation) Link Budget to be applied for the Project: 25dB @ 1310nm We may try however, to keep 23dB @ 1310nm as far as practicable.
  • 6. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 6 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N FTTH-OSP DESIGN PRINCIPLES (2) 3. FTTH OSP Design shall be composed of the following: 3.1 Feeder Cable Design 1) Google Map per STO 2) Skema Kabel Feeder (Schematic Drawing) 3) Skema Duct (Schematic Drawing) 4) Peta Lokasi Duct & Kabel Feeder (Location Map) 5) Special Design (MH Modification, Duct Bridge etc.) 3.2 Distribution Cable Design 1) Google Map per Lokasi 2) Skema Kabel Distibusi 3) Peta Lokasi Distribusi 4) Special Design (HH Modification, Modified ODP Foundation etc.)
  • 7. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 7 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N Feeder Cable DC-OF-SM- 12D/24D/48D/ 96D/144D/288D ODC ODC-C-48/144/288 Splitter Note: ODC-C-48 = Wallmount Type Pass through closure Type/Designator for 48core Star/Ring SC-OF-SM-PT-48 for 96core Star/Ring, 144core Star SC-OF-SM-PT-144S for 144core Ring SC-OF-SM-PT-144R for 288core Star SC-OF-SM-PT-288S for 288core Ring SC-OF-SM-PT-288R Inline closure Type/Designator for 12c-24c SC-OF-SM-24 for 12c-48c SC-OF-SM-48 for 12c-96c SC-OF-SM-96 for 12c-144c SC-OF-SM-144 for 12c-288c SC-OF-SM-288 STO ODC ODP (Aerial) ODP-SSW-8 (1:8 Splitter built-in) Branching ODP (Pole/Wall Mount) ODP-PW-BR Branching ODP (Pedestal) ODP-PL-BR ODP (Wall Mount) ODP-PW-8/16 Distribution Cable (Aerial) AC-OF-SM-8/12/24-SC ODP (Pedestal) ODPPL-8/16 Distribution Cable (Duct) DC-OF-SM-8/12/24-SC Passive Splitter PS-1-2-ODC/ PS-1-4-ODC PS-1-8-ODP Line Guard/ Suspension C-Clamp Materials for FTTH OSP (STO - ODP) OTB TC-OF-SM- 12/24/48/72/96/144
  • 8. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 8 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N Cable Trunking and Accessories Splitter for ODC-HRB PS-1-4-ODC-HRB Materials for FTTH-OSP (HRB: High-Rise Building) ODC-HRB (Cabinet) ODC-HRB-420 ODC-HRB-240 ODC-HRB-180 ODC-HRB(Rack) ODC-HRB-RACK-480 ODC-HRB-RACK-240 ODC-HRB-RACK-120 19 inch Rack TC-OF-R-19 or Indoor Cable (1-C Low Friction) IC-OF-SM-1D ODC-HRB ODP-HRB ODP-HRB-16/32 PS-1-8-ODP-HRB Indoor Cable (2-C Low Friction) IC-OF-SM-2D ROSETTE RS-IN-SC-1P/ TC-MK-SC-1P FUSE-CONNECT ISC-UPC-FD T-JointCable Trunking Elbow (Flat Angle)
  • 9. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 9 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N LIST OF MATERIALS AND INSTALLATION MANUALS (1/2) As of: 01-June-2013 No. Spec.No. Manual.No. Sub manuals 1 - 5. ESMDDLT000*****K 6 ESMDDLT00028824K 7 - 8. JBT-05166A 9 - 12. ESMDALT0000****K 13-16 ENZDSCDLT0*****K 17 - 20 ENZDSCALT00****K 21-23 ESMDDLT0000****K 24 JBT-05027B 25 - 26 JBT-05026-> JBT-05391 49 - 50 JBT-04109A 51 - 52 JBT-04770D 53 - 54 JBT-04109A 55 - 56 PNJHC-1101-54-02(2.8mm) 57 - 75 TS1211-01 76 - 78 PNJBC-0516-54-03 PNJBC-0516-82-01 ODC-C sub manual_130214 79 PNJBC-0516-54-04 PNJBC-0516-82-01 ODC-C sub manual_130214 80-81 PNJCS-0013-54-10 82 - 83 PNJCY-0085-54-03 PNJCY-0085-82-01 ODP-CA sub manual_130323 84 - 87 PNJBC-0516-54-06 88 - 89 JEMBO Pedestal + ODP-CA PNJCY-0085-82-01 90 - 95 PNJBC-0516-54-07 PNJBC-0516-82-04 TC-SM sub manual_130225 96 PNJBC-0470-54-04 PNJBC-0470-82-02 97 PNJBC-0472-54-08A 98 PNJBC-0516-54-08 99-101 PNJBC-0516-54-09 PNJBC-0516-82-06 102 - 106 PNJBC-0516-54-10 107 - 111 PNJSC-1077-54-03Rev.1 112 - 116 PNJBC-0516-54-11 117 - 121 PNJSC-1077-54-04Rev.1 200 PNJCY-0084-54-02 201 PNJCY-0084-54-01 202 PNJCY-0084-54-04 203 PNJCY-0084-54-03 204 PNJCY-0084-54-05 Manuals will be available upon supply of the material Manauals not applicable DC-OF-SM-*D (SM.D D - LT */*T) DC-OF-SM-*-SC (SM.D D - LT */*T) AC-OF-SM-8-SC (OGGDE-SSW) Name File AC-OF-SM-*D (SM.D A - LT */*T) DC-OF-SM-*C (NZDS.C D - LT */*T) AC-OF-SM-*C (NZDS.C A - LT */*T) DC-OF-SM-288D (SM.D D - LT 288/24T) DC-OF-SM-*D (OG8ETSWBE) AC-OF-SM-*-SC (OGNM4WTGDE-SSW) GC-OF-SM-1D (FR-OGINE) HC-OF-SM-*D (FR-OGNMGDE-SSD) GC-OF-SM-1D (FR-OGINE) Patch cord (2.8mm, BIS-B) Pigtails and Patchcords ODC-C-* Splitter ODC-C-48 Splitter ODC-CU (FSCO-HHS) ODP-CA-* for Pole Mount ODP-A-* ODP-PL-* (Pedestal_Box+ ODP-CA-* For_Wall_mount) TC-SM-* RS-IN-SC-1P (FPB-103A(S)) RS-IN-SC-2P (FPB-302-2SC(PT)) House Hook Cable cleat RS-IN-SC-4P (RS-IN-SC-4) TC-MK-SC-* PS-1-*-ODC (Optical Spitter Module 1 x N Type) PS-1-*-ODP(PLC Type 1xN Splitter) PS-2-*-ODC (Optical Spitter Module 2 x N Type) PS-2-*-ODP (PLC Type 2xN Splitter) Deadending Wire Vice (C clamp) Drop Cable Clamp (S Clamp) Selft-Support Wire Line Guard (Line Guard 2.6mm)
  • 10. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 10 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N LIST OF MATERIALS AND INSTALLATION MANUALS 2/2) As of: 01-June-2013 No. Spec.No. Manual.No. Sub manuals 205 PNJCY-0084-54-06 206 PNJCY-0084-54-07 207 PNJCY-0084-54-08 400 - 401 PNJHC-1101-53-01 402 PNJCY-0067-54-18 PNJC-0067-82-04 403 PNJHY-0001-53-11 404 PNJHY-0001-53-10 405 PNJHY-0107-53-05 406 PNJHY-0107-54-21Rev.2 JDAA-11-12-0048D PNJHY-0107-54-21Rev.2 JDAA-11-13-0075 407 PNJBC-0480-54-17 408 PNJBC-0480-54-17 409 PNJBC-0480-54-17 410 B-12F0401 PNJCY-0085-82-03 411 B-12F0401 PNJCY-0085-82-03 412 PNJBC-0085-54-02 PNJCY-0085-82-01 413 PNJBC-0085-54-02 PNJCY-0085-82-01 414 JBT-04260B 415 JBT-04260B 416 417 418 419 420 421 PNJBC-0516-54-12 PNJBC-0516-82-09A 422 PNJBC-0516-54-12 PNJBC-0516-82-09A 423 PNJBC-0516-54-12 PNJBC-0516-82-09A 424 PNJBC-0516-54-13 PNJBC-0516-82-10 425 PNJBC-0516-54-13 PNJBC-0516-82-11 426 PNJBC-0527-54-07 427 PNJBC-1077-54-03Rev.1 Manuals will be available upon supply of the material PS-1-8-ODP-HRB ODP-HRB-16 PS-1-4-ODC-HRB Pass through closureType4 ( For 288core Ring) ODC-HRB-420 ODC-HRB-240 ODC-HRB-180 ODP-HRB-32 Low Friction Indoor Cable , 2C Pass through closureType1 ( For 48core Star/Ring ) Pass through closureType2 ( For 96core Star/Ring ) Pass through closureType3 ( For 144core Ring ) Pass through closureType4 ( For 288core Star) ODP-BR for Branching (3 Hole Type) , Pole mounting type ODP-BR for Branching (3 Hole Type) , termasuk Dome Pedestal ODP Outdoor/Wall , Termasuk Adaptor , Space Passive Splitter, 8 Port ODP Outdoor/Wall , Termasuk Adaptor , Space Passive Splitter, 16 Port Low Friction Indoor Cable , 1C Outdoor Optical Connector Cabinet (FPB-203-*SC-A (PT)) 4 Port L-clamp Flex Band IBT-206 BW-Clamp Free Bending Optical cord (3mm, BIS-B) Outdoor Optical Connector Cabinet (FPB-203-*SC-A (PT)) 1 Port Outdoor Optical Connector Cabinet (FPB-203-*SC-A (PT)) 2 Port ODP-SSW (FSCO-AS-SP(in/splice)) FIELD INSTALLBLE SC CONNECTOR (FAST-SC-SM-09/CO) FIELD INSTALLBLE SC CONNECTOR (FAST (N) -SC-SM-UNI/GT) FUSION CONNECTOR (Fuseconnect-SC-SF-SM-20/30) FUSION CONNECTOR (Fuseconnect-SC-DC) for Drop cable FUSION CONNECTOR (Fuseconnect-SC-LF) for LowFriction cable Name File Manauals not applicable
  • 11. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 11 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 1. FEEDER CABLE DESIGN A. The Feeder Cable Route shall be planned to utilize the existing duct route as the first priority so as to minimize the road excavation length. B. The capacity of Feeder Cables designed/implemented by the previous TOS/PO as well as for the followings shall be taken into account at the Feeder Cable Capacity Planning: 1) AL PRO: Existing Facility such as MSAN, RK, etc. 2) Node B Project 3) GDI: Government Digitalization Network 1.1 GOOGLE MAP 1) Nama STO: legend berbentuk Rumah (Warna Merah) 2) Route Feeder: warna Merah 3) Nama ODC sesuai dengan Lokasi/Cluster 4) Kapasitas ODC/ Jumlah Homepass 5) Boundary ODC/Lokasi/Cluster dg Boundary Area Potensi
  • 12. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 12 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 1.2 SKEMA KABEL FEEDER ► Purpose: Information required for the Feeder Cable Work A. OTB at STO OTB to be installed with the symbol Telkom Standard and indicated with the designator in BoQ: Example: TC-OF-SM-xx (yy) B. Feeder Cable Indication: Black Line (New: 0.6 point, Existing: 0.3 point) Information: 1) Type (Duct/Aerial) and capacity of cable 2) Length of cable 3) Core Assignment Note: The younger core number shall be assigned for the far end (the last position) and spare cores (Cadangan). Total Quantity of OTB Type of OTB
  • 13. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 13 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N IDENTIFICATION OF FEEDER CABLE FE XXX 01-01-01 (01-288) Core No. In Cable Segment No. Feeder No. Code STO Code Feeder Cable DC-OF-SM-XXX-xxxxM Cable Length in meter No. Of Cores Type of Cable Duct Cable: DC-OF-SM Aerial Cable: AC-OF-SM Branch-Segment No. Note: Cable Line: New: Tebal (e.g. 6pt.) Existing: Tipis (e.g. 3pt.) Identification: New: Bold Font Existiong: Normal Font
  • 14. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 14 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N C. ODC D. MH/HH/CLOSURE 1) MH/HH: Name of Existing MH/HH or Type of New MH/HH 2) Closure: a. Straight Joint: SC-OF-SM-xxx b. Pass-through Joint: SC-OF-SM-xxx-PT ODC Capacity ODC No. “FA”, “FB”, ....... Code STO Code ODC xx PS 1:4 (xxx HP) Number of Homepass Code Splitter 1:4 Number of Splitter 1:4 Coordinates Lokasi ODC ODC-XXX-FA-288 ( - ) Assigned core to be terminated
  • 15. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 15 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 1.4 SAMPLE DESIGN OF FEEDER CABLE NETWORK 1.3 PETA LOKASI DUCT & KABEL FEEDER ►►►► Purpose: Information required for the Civil Work shall be plot on the scaled map 1) SKEMA DUCT (Refer to 1.4.1) 2) SKEMA KABEL FEEDER (Refer to 1.4.2) 3) PETA LOKASI KABEL FEEDER (Refer to 1.4.3) Lokasi CC ODC-ABC-F -288 STO ABC 24 15.0 ABC 01/01 ABC 01/02 ABC 01/03 ABC 01/xx ABC 01/yy 6 6 664 ABC 02/02 ABC 02/01 ABC 02/xx 100.0 100.0 100.0100.0100.0 HH-2 HH- 80 DD-BM-HDPE-1 35.0 HH-1 HH-1 DD-BM-HDPE-1 150.0 DD-BM-HDPE-BIG-1DD-BM- HDPE- BIG-1 150.0 bbb. 0 Lokasi AA ODC-ABC-F -144 Lokasi BB ODC-ABC-F -288 Lokasi DD ODC-ABC-F -144 JL.ABCRAYA JL.ABCII JL.ABC I aaa.0 DD-BM- HDPE- BIG-1 HH-1 Cableslack(10)shallbeprovidedat every1000mofcablelength.(Incase ofDD-BM-HDPE,HH-1/2shallbe installed.) Legend: : Assigned Duct for New Cable : Vacant Duct : Occupied Duct Lokasi CC ODC-ABC-F -288 xx PS 1:4 (yyHP) (241-288) NNNN xxxxxxxxxxxx°°°°xxx.xxxx E yyy °°°° yyy.yyyy Lokasi DD ODC-ABC-F -144 xx PS 1:4 (yyHP) (217-240) NNNN xxxxxxxxxxxx°°°°xxx.xxxx E yyy °°°° yyy.yyyy Lokasi AA ODC-ABC-F -144 xx PS 1:4 (yyHP) (121-144) NNNN xxxxxxxxxxxx°°°°xxx.xxxx E yyy °°°° yyy.yyyy Lokasi BB ODC-ABC-F -288 xx PS 1:4 (yyHP) (73-120) NNNN xxxxxxxxxxxx°°°°xxx.xxxx E yyy °°°° yyy.yyyy STO ABC TC-SM-144 (3) FE-ABC-01-01 (01-144) DC-OF-SM-144D m FE-ABC-01-01-01 (121-144) DC-OF-SM-24D m FE-ABC-01-02(01-120) DC-OF-SM-144D m FE-ABC-01-02-01 (73-120) DC-OF-SM-48D m CAD (01 – 72) FE-ABC-02-01(01-288) DC-OF-SM-288D m DC-OF-SM-288D m FE-ABC-02- 02 (01-240) CAD (01 – 216) FE-ABC-02-01-01 (241-288) DC-OF-SM-48D m FE-ABC-02-02-01 (217-240) DC-OF-SM-48D m JL.ABCRAYA JL.ABC I JL.ABCII ABC 01/02 ABC 01/yy DC-OF-SM-288D m FE-ABC-02- 02 (01-240) Cable Slack (10m) shall be placed every 1000m of cable span and/or the location where the future demand is expected. STO ABC 100.0 ABC 01/01 DD-BM-HDPE-1 150.0 DD-BM-HDPE-1 35.0 HH- 80 HH-2 HH-1 HH-1 DD-BM-HDPE-BIG-1 150.0 JL.ABCRAYA JL.ABCII JL.ABC I Lokasi BB ODC-ABC-F -288 Lokasi AA ODC-ABC-F -144 Lokasi CC ODC-ABC-F -288 Lokasi DD ODC-ABC-F -144 DD-BM-1 10.0 DD-BM-1 10.0 DD-ROD-1 15.0 DD-ROD-1 xxxx.0 ABC 01/02 ABC 01/03 ABC 01/xx DD-BM-HDPE- BIG-1 bbb. 0 aaa. 0 DD-BM-HDPE- BIG-1 HH-1 ABC 02/03 ABC 02/01 ABC 02/xx ABC 01/xx ABC 01/xx ABC 01/yy ABC 02/02 DD-ROD- 1 100000000.0 DD-ROD- 1 100000000.0 DD-ROD- 1 100000000.0 DD-ROD- 1 xxx.0 DD-ROD- 1 100000000.0 DD-ROD- 1 100000000.0 DD-ROD- 1 xxx.0 DD-ROD- 1 100000000.0 DD-ROD- 1 100000000.0 DD-ROD- 1 xxx.0
  • 16. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 16 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 1.4.1 SKEMA DUCT STO ABC 24 15.0 ABC 01/01 ABC 01/02 ABC 01/03 ABC 01/xx ABC 01/yy 66 664 ABC 02/02 ABC 02/01 ABC 02/xx 100.0100.0 100.0100.0100.0 HH-2HH-80 DD-BM-HDPE-1 35.0 HH-1HH-1 DD-BM-HDPE-1 150.0 DD-BM-HDPE- BIG-1 DD-BM-HDPE- BIG-1 150.0bbb.0 Lokasi AA ODC-ABC-F -144 Lokasi BB ODC-ABC-F -288 Lokasi CC ODC-ABC-F -288 Lokasi DD ODC-ABC-F -144 JL.ABC RAYA JL.ABC II JL.ABCI aaa.0 DD-BM-HDPE- BIG-1 HH-1 Cable slack (10) shall be provided at every 1000m of cable length. (In case of DD-BM-HDPE, HH-1/2 according to Page 23, 1.6.3 shall be installed.) Legend: : Assigned Duct for New Cable : Vacant Duct : Occupied Duct
  • 17. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 17 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 1.4.2 SKEMA KABEL FEEDER Lokasi CC ODC-ABC-F -288 xx PS 1:4 (yyHP) (241-288) NNNN xxxxxxxxxxxx°°°°xxx.xxxx E yyy °°°° yyy.yyyy Lokasi DD ODC-ABC-F -144 xx PS 1:4 (yyHP) (217-240) NNNN xxxxxxxxxxxx°°°°xxx.xxxx E yyy °°°° yyy.yyyy Lokasi AA ODC-ABC-F -144 xx PS 1:4 (yyHP) (121-144) NNNN xxxxxxxxxxxx°°°°xxx.xxxx E yyy °°°° yyy.yyyy Lokasi BB ODC-ABC-F -288 xx PS 1:4 (yyHP) (73-120) NNNN xxxxxxxxxxxx°°°°xxx.xxxx E yyy °°°° yyy.yyyy STO ABC TC-SM-144 (3) FE-ABC-01-01 (01-144) DC-OF-SM-144D m FE-ABC-01-01-01 (121-144) DC-OF-SM-24D m FE-ABC-01-02 (01-120) DC-OF-SM-144D m FE-ABC-01-02-01 (73-120) DC-OF-SM-48D m CAD (01 – 72) FE-ABC-02-01 (01-288) DC-OF-SM-288D mDC-OF-SM-288D m FE-ABC-02-02 (01-240) CAD (01 – 216) FE-ABC-02-01-01 (241-288) DC-OF-SM-48D m FE-ABC-02-02-01 (217-240) DC-OF-SM-48D m JL.ABC RAYA JL.ABCI JL.ABC II ABC 01/02 ABC 01/yy DC-OF-SM-288D m FE-ABC-02-02 (01-240) Cable Slack (10m) shall be placed every 1000m of cable span and/or the location where the future demand is expected. (Note: Do not show on drawing) ( )
  • 18. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 18 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 1.4.3 PETA LOKASI KABEL FEEDER STO ABC ABC 01/01 DD-BM-HDPE-1 150.0 DD-BM-HDPE-1 35.0 HH-80 HH-2 HH-1 HH-1 DD-BM-HDPE- BIG-1 150.0 JL.ABC RAYA JL.ABC II JL.ABCI Lokasi BB ODC-ABC-F -288 Lokasi AA ODC-ABC-F -144 Lokasi CC ODC-ABC-F -288 Lokasi DD ODC-ABC-F -144 DD-BM-1 10.0 DD-BM-1 10.0 DD-ROD-1 15.0m ABC 01/02 ABC 01/03 ABC 01/xx DD-BM-HDPE- BIG-1 bbb.0aaa.0 DD-BM-HDPE- BIG-1 HH-1 ABC 02/02 ABC 02/01 ABC 02/xx ABC 01/xx ABC 01/xx ABC 01/yy ABC 02/03 DD-ROD-1 xxx.0m DD-ROD-1 100.0m DD-ROD-1 100.0m DD-ROD-1 100.0m DD-ROD-1 100.0m DD-ROD-1 100.0m DD-ROD-1 100.0m DD-ROD-1 100.0m DD-ROD-1 xxx.0m DD-ROD-1 xxx.0m 1. FE-ABC-01 2. FE=ABC-02 Note: In case if plural cables will be installed in one (1) route, Cable No. to be installed shall be indicated.
  • 19. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 19 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 1.5 CORE ASSIGNMENT DIAGRAM 1. CORE ASSIGNMENT DIAGRAM shall be prepared prior to draw the SKEMA KABELas a tool so as to arrange the core assignment of the feeder cable easily. (Not for submission purpose) 2. CORE ASSIGNMENT DIAGRAM shall be prepared per each FEEDER CABLE. 3. The higher number of core (e.g. 288 in 288-core cable) shall be assigned from the nearest ODC, and the youngest number shall be assigned for the furthest ODC or CAD (Spare core). START FEEDER CABLE ROUTE PLAN: => Draft for Skema Feeder 1. SKEMA DUCT EXISTING shall be referred as the basic information for the Feeder Cable Route Plan. 2. Plot all ODCs TO BE FED BY THE CABLE together with its capacity along the existing duct route. 3. Where the existing duct is not available, new duct construction or DD-BM-HDPE shall be planned. 4. Plot all prospected/ potential locations including Al-Pro, MSAN, GDI etc. along the expected feeder cable route. Decision of Network Configuration: 1.Ring 2.Star/Bus SUM UP the required number of fiber cores: 1.ODC-144: 24 cores 2.ODC-288: 48 cores Decision of Feeder Cable Capacity: 1.Required number of cores ≤ 96 → 96C 2.Required number of cores 97 ≥, ≤ 144 → 144 3.Required number of cores 145 ≥, ≤ 288 → 288 4.Required number of cores ≥ 288 → 288 + another cable according to the required capacity Preparation of CORE ASSIGNMENT DIAGRAM END FLOW OF CORE ASSIGNMENT DIAGRAM PREPARATION
  • 20. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 20 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 1.5.1 EXAMPLE OF CORE ASSIGNMENT DIAGRAM (1): STAR/BUS TOPOLOGY SKEMA KABEL FEEDER (Reference for Main Information) Lokasi AA ODC-288 (241 – 288) Lokasi CC ODC-144 (169 – 192) Lokasi DD ODC-144 (145 – 168) Lokasi BB ODC-288 (193 – 240) CAD (72) (01 – 72) Lokasi EE ODC-288 (97 – 144)CAD (24) (73 – 96) (01 – 288) (288) (288) (288) (01 – 240) (01 – 192) (145 – 192) (01 – 72) (96) (48) (145 – 168) (24) (48) (97 – 144) (48) (193 – 240) (48) (241 – 288) (24) (169 – 192) STO ABC TC-OF-SM-144 (2) 01 - 24 25 - 48 49 - 72 73 - 96 97 - 120 121 - 144 145 - 168 169 - 192 193 - 216 217 - 240 241 - 264 265 - 288 Lokasi AA ODC-288 (241 – 288) Lokasi BB ODC-288 (193 – 240) STO ABC Lokasi CC ODC-144 (169 – 192) Lokasi DD ODC-144 (145 – 168) CAD (73 – 96) CAD (72) (01 – 72) Lokasi EE ODC-288 (97 – 144)(288) (96) (48) (48) (24) (24) (48) LEGEND: : Joint Closure : Fusion Splicing : Cable (Core) (XX)
  • 21. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 21 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 1.5.2 EXAMPLE OF CORE ASSIGNMENT DIAGRAM (2): RING TOPOLOGY Lokasi DD ODC-288 (145 – 192) 01 24 25 48 49 72 73 96 97 120 121 144 145 168 169 192 193 216 217 240 241 264 265 288 265 288 241 264 217 240 193 216 169 192 145 168 121 144 97 120 73 96 49 72 25 48 01 24 Lokasi AA ODC-144 (265 – 288)STO ABC Lokasi CC ODC-288 (193 – 240) Lokasi EE ODC-144 (121 – 144) Lokasi GG ODC-288 (49 – 96) Lokasi BB ODC-144 (241 – 264) Lokasi DD ODC-288 (145 – 192)Lokasi FF ODC-144 (97 – 120) CAD (01 – 48) CAD (01 – 48) SKEMA KABEL FEEDER (Reference for Main Information) STO ABC TC-OF-SM-144 (4) Lokasi AA ODC-288 (241 – 288) (01 – 288) (01 – 288)(01 – 288) Lokasi BB ODC-144 (241 – 264) Lokasi CC ODC-288 (193 – 240) Lokasi EE ODC-144 (121 – 144) Lokasi FF ODC-144 (97 – 120) Lokasi GG ODC-288 (49 – 96) (48) (48) (48) (48) (96) (96) (96)
  • 22. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 22 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 1.6 GENERAL CONCEPT FOR FEEDER CABLE DESIGN 1.6.1 ODC SPEC. (Non-HRB Type) ODC type Designator Splitter (1:4) Maximum HP Feeder (input Fiber core) Number of Cable Entry (Input+Output) 48 (pole) ODC-C-48 Splitter Max. 6pcs 6x32=192 Star ; 12C Ring ; 24C 4 96 (pedestal) ODC-C-96 Splitter Max. 8pcs 8*32=256 Star ; 12C Ring ; 24C 8 144 (pedestal) ODC-C-144 Splitter Max. 18pcs 18x32=576 Star ; 24C Ring ; 48C 12 288 (pedestal) ODC-C-288 Splitter Max. 36pcs 36x32=1152 Star ; 48C Ring ; 96C 12 576 (pedestal) ODC-C-576 Splitter Max. 72pcs 72x32=2304 Star ; 96C Ring ; 192C 24 1.6.2 FEEDER CABLE SPEC. Fiber Count Number of Tubes Number of Fiber/Tube Tube Diameter Outer Diameter Bending Radius (20 x OD) 12C 2 6 2.1mm 12.8mm 25.6cm 24C 4 6 2.1mm 12.8mm 25.6cm 48C 4 12 2.5mm 13.9mm 27.8cm 96C 8 12 2.5mm 15.6mm 31.2cm 144C 12 12 2.5mm 19.1mm 38.2cm 288C 24 12 2.5mm 22.1mm 44.2cm
  • 23. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 23 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 1.6.3 HDPE PIPE/HANDHOLE for FEEDER CABLE In case when the existing duct is not available and new duct (HDPE) will be installed, the following shall be taken into consideration: 1) Feeder Cable with the capacity 288-core: ► HDPE BIG/SUBDUCT BIG shall be used. ► Hand-hole Type HH-1 (L=1700 x W=1250 x D=1300) shall be used for all locations. 2) Feeder Cable with the capacity 144-core ► HDPE 33/40/SUBDUCT shall be used. ► Hand-hole Type HH-1 (L=1700 x W=1250 x D=1300) shall be used for all locations. 3) Feeder Cable with the capacity 96-core or less ► HDPE 33/40/SUBDUCT shall be used. ► Hand-hole Type HH-2 (L=1200 x W=600 x D=1300) shall be used for all locations 1.6.4 HANDHOLE for ODC At ODC location, HANDHOLE shall be installed: 1) Type HH-1 (L=1700 x W=1250 x D=1300): ► Where the Jointing Closure from the Feeder Cable with 288/144-core.is installed including the location where slack is located for future jointing. 2) Type HH-2 (L=1200 x W=600 x D=1300): ► Where Handhole shall be located on the carriage way. 3) Type HH-80 (L=800 x W=800 x D=800): ► Where Handhole will be located on the Green Area (Taman) in the housing area (Perumahan) and where no jointing closure will be located.
  • 24. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 24 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 1.6.5 PASS THROUGH CLOSURE for FEEDER CABLE Through Cable Type Model No. (3M) 48core 2179CS Type 1 : 24core tray (1) Size ; 447mm x 175mm x 107mm 96core, 144core 2179C Type 2 : 24core tray (1) Type 3 : 24core tray (2) Size ; 557mm x 215mm x 119mm 288core 2178LS Type 4 : 24core tray (2) Type 5 : 24core tray (4) Size ; 557mm x 216mm x 203mm Option: 24core tray , Re-entry kit Consultation shall be necessary in case when the other optional items are required.
  • 25. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 25 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 2. DISTRIBUTION CABLE DESIGN Maximum Usage of Distribution Cable shall be 80% of the cable capacity: Maximum No. of ODP: No. of Spare Core (CADANGAN) 1) 8-Core Cable: 6 (Only for Branch Section) 2 CORE CAD. 2) 12-Core Cable: 10 2 CORE CAD. 3) 24-Core Cable: 20 4 CORE CAD. 2.1 GOOGLE MAP 1) ODC (Name/Capacity) 2) Distribution Cable Route 3) Location of ODP 2.2 SKEMA KABEL DISTRIBUSI ► Purpose: Information required for the Distribution Cable Work 1) ODC ODC Capacity ODC No. “FA”, “FB”, ....... Code STO Code ODC ODC-XXX-FA-288
  • 26. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 26 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 2) DISTRIBUTION CABLE DSXXX-FE 01-01-01/01-01-01 (01-24) Core No. In Cable Segment No. Label Feeder (Feeder No., Segment No.)Code STO DC-OF-SM-24SC-xxM Cable Length in meter Designation for “Easy to Split” Cable No. Of Cores Type of Cable Duct Cable: DC-OF-SM Aerial Cable: AC-OF-SM Code Distribution Cable Distribution No. Branch-Segment No.
  • 27. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 27 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 3) ODP FA/D01/xx/yy (xx) No. No. Number of Splitter 1:8 “1”: ODC-8 “2”: ODC-16 ODP No. Note: 1. Continuous number starting from D01: example: 10 ODP on D01, ODP on D02 shall be started from No.11. 2. ODP No. shall be given from the far most ODP from ODC location. Distribution Cable No. ODC No. Core No. to be terminated at ODP e.g. from 01 to 24 The largest No. of care shall be allocated to the nearest ODP from ODC. House No. in front of ODP Location Coordinates Lokasi ODP Note: Grounding shall be placed at the last ODP for each distribution cable.
  • 28. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 28 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 2.3 SAMPLE DESIGN OF DISTRIBUTION CABLE NETWORK 1) SKEMA KABEL DISTRIBUSI 2) PETA LOKASI KABEL DISTRIBUSI 2.3.1 CASE-1: UNDERGROUND/DUCT CABLE ODC-F -144 xx PS 1:4 (yyHP) DSABC-FE-01-01/01-01 (01-12) DSABC-FE-01-01/01-02 (01-10) DSABC-FE-01-01/01-03 (01-09) DSABC-FE-01-01/01-xx (01-05) F /D01/07/02 (11-12) N ... E ....... N ... E ....... F /D01/06/01 (10) N ... E ....... F /D01/05/01 (09) ODP-PW-BR N ... E ....... F /D01/01/02 (03-04) N ... E ....... CAD (01-02) DC-OF-SM-12-SC ..m DC-OF-SM-12-SC ..m DC-OF-SM-12-SC ..m DC-OF-SM-12-SC ..m 3 4 9 10 16 17 31 F /D01/04/01 (08) DSABC-FE-01-01/01-03-01 (08) DC-OF-SM-8-SC ..m N ... E ....... JL. .. HH-2 ODC-F -144 xx PS 1:4 (yyHP) DD-BM-HDPE-1 ..m DD-BM-HDPE-1 ..m DD-BM-HDPE-1 ..m DD-BM-HDPE-1 ..m DD-BM-1 ..m DD-BM-1 ..m DD-BM-1 ..m DD-BM-HDPE-1 ..m DD-BM-HDPE-1 ..m DD-BM-HDPE-1 ..m DD-BM-1 ..m DD-BM-HDPE-1 ..m DD-BM-1 ..m 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 29 30 31 32 DD-BM-HDPE-1 ..m F /D01/07/02 F /D01/06/01 F /D01/05/01 ODP-PW-BR F /D01/01/02 F /D01/04/01 JL. .. Note: At the BRANCHING, the core assignment and the ODP No. shall be in accordance with the rule below.
  • 29. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 29 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N STO ABC NAMA LOKASI Cluster AA (ODC-F -144) DISTRIBUTION CABLE No. D-01 CAPACITY 12-CORE FEEDER SEGMENT DISTRIBUTION SEGMENT OTB Port No. ODC PORT No. SPLITTER 1:4 ODC TRAY CORE No.No. Port No. PORT No. 49 1 1 1 1 1 1 2 2 2 3 3 3 4 4 4 50 2 2 1 5 5 2 6 6 3 7 7 4 8 8 51 3 3 1 9 9 2 10 10 3 11 11 4 12 12 7 6 5 4 3 2 3) CORE ASSIGNMENT DIAGRAM (For CASE-1) 1 CAD 8-C
  • 30. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 30 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 2.3.2 CASE-2: AERIAL CABLE 1) SKEMA KABEL DISTRIBUSI 2) PETA LOKASI KABEL DISTRIBUSI ODC-F -144 xx PS 1:4 (yyHP) DSABC-FE-01-01/01-01 (01-12) DSABC-FE-01-01/01-02 (01-11) DSABC-FE-01-01/01-03 (01-10) DSABC-FE-01-01/01-xx (01-05) F /D01/08/01 (12) N ... E ....... N ... E ....... F /D01/07/01 (11) N ... E ....... F /D01/06/01 (10) ODP-PW-BR N ... E ....... F /D01/01/01 (05) N ... E ....... CAD (01-04) AC-OF-SM-12-SC ..m AC-OF-SM-12-SC ..m AC-OF-SM-12-SC ..m AC-OF-SM-12-SC ..m 3 4 9 10 16 17 31 F /D01/05/01 (09) DSABC-FE-01-01/01-03-01 (09) AC-OF-SM-8-SC ..m N ... E ....... JL. .. HH-2 ODC-F -144 xx PS 1:4 (yyHP) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 29 30 31 32 F /D01/08/02 F /D01/07/01 F /D01/06/01 ODP-PW-BR F /D01/01/01 F /D01/05/01 JL. .. BC-PP 3m 30m 45m 45m 45m 45m 25m.m LEGEND : New Pole : Existing Pole Branching ODP (1 x 1:8 Splitter) ODP Aerial (1 x 1:8 Splitter) 30m Note: At the BRANCHING, the core assignment and the ODP No. shall be in accordance with the rule below.
  • 31. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 31 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 3) CORE ASSIGNMENT DIAGRAM (For CASE-2) STO ABCABCABCABC NAMA LOKASI Cluster AA (ODC-F -144) DISTRIBUTION CABLE No. D-01 CAPACITY 12-CORE FEEDER SEGMENT DISTRIBUTION SEGMENT OTB Port No. ODC PORT No. SPLITTER 1:4 ODC TRAY CORE No. No. Port No. PORT No. 49494949 1111 1111 1 1111 1 1 2 2 2 3 3 3 4 4 4 50505050 2222 2222 1 5 5 2 6 6 3 7 7 4 8 8 51515151 3333 3333 1 9 9 2 10 10 3 11 11 4 12 12 ODP No. 15 34 2678 CAD 12-C 12-C 8-C
  • 32. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 32 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N Main Cable (SCPT-8/12/24-core) ODP Pedestal/Wall Capacity: 8 or 16 ODP Pedestal/Wall Capacity: 8 or 16 Branching Cable (SCPT-8-core) Branching ODP (1 x 1:8 Splitter) Designator: ODP-PL-BR 2.4 BRANCHING ODP 1) Underground Cable (Pedestal/Wall Mount) Branching ODP shall be used in case when the several ODP locations are not suitable to be fed by the main cable but independent cable installation is also not efficient due to the limited number of ODP (Less than 8 ODP). Branching ODP: 1)Branching ODP is applicable for both underground as well as aerial distribution cable design. 2)Type of ODP is “Cabinet” type to be mounted on: WALL, POLE and PEDESTAL. 3)The cable to be branched from the main cable shall be of “8-Core”. 4)The number of ODP on branched cable shall be less than 8. 5)The branching ODP is able to accommodate only one (1) unit of 1:8 Splitter. 2) Aerial Cable (Pole Mount) Main Cable (SSW-8/12/24-core) ODP Aerial Capacity: 8 ODP Aerial Capacity: 8Branching Cable (SCPT-8-core) Branching ODP (1 x 1:8 Splitter) Designator: ODP-P/W-BR
  • 33. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 33 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 2.5 DUCT USAGE FOR DISTRIBUTION NETWORK & DROP-CORE INSTALLATION (UNDERGROUND) ODC – ODP/ ODP – ODP 1)DD-BM-HDPE 2)BC-TR-1.5 + DD-HDPE ODP (HH-PIT-60) – HH-PIT-40/ HH-PIT-40 – HH-PIT-40 1) BC-TR-0.6 + DC-SD-1 BigHH-PIT-60 HH-PIT-40 HH-PIT-40 HH-PIT-40 - Premises 1) BC-TR-0.4 + PP-OF-OUT(PVC ¾”)
  • 34. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 34 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 3. GENERAL CONCEPT FOR DISTRIBUTION CABLE DESIGN 1) Bila ditemukan jalan buntu pada perumahan dengan jalak Drop core <100 meter maka penempatan ODP diletakkan di ujung jalan masuk Blok Perumahan, Gambar Terlampir: 1) When you find a blind alley which need drop core cable less than 100 m, the ODP should be placed at the entrance of the alley. Please see the illustration below. General Preparation for the Distribution Cable Design: Prior to plotting ODP on the map, ODP Boundary (Max. 8 or 16HP) shall be designated so that the number of ODP and its location can be planned efficiently. 3.1 DUCT/BURIED SECTION
  • 35. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 35 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 2) Bila ditemukan jalan buntu pada perumahan dengan jalak Droop core >100 meter maka diperbolehkan menggunakan ODP Branch dari kabel distribusi untuk kabel yang akan menuju ke ODP dengan jumlah branch sesuai denga HP, Gambar Terlampir : 2) When you find a blind alley which need drop cable more than 100 m, it is allowed to use the ODP Branch from the main distribution cable according to the quantity of HP. Please see the illustration below.
  • 36. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 36 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 3) Bila ditemukan jalan tidak buntu pada perumahan maka penarikan kabel distribusi dapat dilakukan secara mengelilingi perumahan yang letak ODP di sesuaikan dengan jumlah HP, Gambar Terlampir : 3) When it is not a blind alley, span of the cable should pass around the complex and placement of ODP should be adjusted according to the HP. Please see the illustration below.
  • 37. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 37 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 3.2 AERIAL SECTION 1) Sample Design based on Duct Cable Design Standard => (Some consideration due to particularity of the aerial cable shall be required.) 6.5m 45m 6.5m 30m 45m 45m 40m 45m 45m 45m11m 45m 45m 25m 25m 6.5m 35m 45m 45m 45m Road width more than 6m Road width less than 6m AC-OF-SM-12-SC AC-OF-SM-8-SC AC-OF-SM-8-SC AC-OF-SM-12-SC ODP-BR ODP-BR Note: Location where special consideration is required due to a particularity of the aerial cable installation : ODC : ODP 1) ODP-SSW-8 2) ODP-BR : HH-2/HH-80 : New Pole 7m/9m LEGEND C-CLAMP x 2 Detail for Riser Part SSW CABLE Cable part shall be protected with Spiral for outdoor use (Black color) Detail for Riser Part Note: Prior to plotting ODP on the map, ODP Boundary (Max. 8HP) shall be designated so that the number of ODP and its location can be planned efficiently.
  • 38. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 38 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 2) Sample Design based on Particularity for Aerial Cable : Additional Pole for Drop Core LEGEND for Additional Item : Drop Core Run 6.5m 45m 6.5m 40m 45m 45m 40m 45m 45m 45m 11m 45m 45m 25m 25m 6.5m 35m 45m 45m 45m Road width more than 6m Road width less than 6m 30m 35m 10m 15m 25m 30m 30m 40m 35m 25m 35m Detail "Drop-A" Detail "Drop-B" Detail "Drop-C" Note: Location where special consideration is taken due to a particularity of the aerial cable installation Some particular consideration required for Aerial Cable Design 1. Additional pole(s) may be required for the drop cable installation. (Actual installation of additional poles shall be decided in accordance with contract with the developper/owner) 2. Road width less than 6m can be crossed by the drop cable as far as the road traffic will not be disturbed otherwise new pole shall be installed. 3. Location of ODP shall be decided so that: 1) Drop cable can be installed along SSW cable. 2) Drop cable can be installed indipendently for one (1) span (2 spans at maximum)
  • 39. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 39 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N C-CLAMP x 2 SSW CABLE Cable part shall be protected with Spiral for outdoor use (Black color) 3) Details of SSW Installation A. Details of Riser Part B. ODP-SSW Location 10cm ODP-SSW-8 B-1. With C-CLAMP C. Cable Allignment As far as it is practical, the cable shall be installed so that the suspension wire is always above the cable part. Suspension Wire Cable Part At the cable laying, turns in the cable shall be released by turning the cable winding while making the 8-figure. 50mm Bend 150mm remove sheath D. C-LAMP E. Line Guard Installation ±30cm Line Guard L= 51cm ODP-SSW-8 B-2. With LINE GUARD SUSPENSION CLAMP ±25cm < 120°°°° LINE GUARD shall be installed where: 1. One (1) in every three (3) poles in the straight line. 2. At the pole beside the ODP-SSW is installed except the location where C- CLAMP is installed. Caution: LINE GUARD shall be fixed and the Suspension Wire at C-CLAMP shall be bent ONLY after all ODP-SSW installation have been completed and the cable allignment has been confirmed so that no turn is contained in the cable span. : SSW Cable (Japan) LEGEND : C-Clamp (Japan)
  • 40. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 40 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N Drop Cable (Aerial) HC-OF-SM-2D 4) Details of Drop-Core Solution Detail "Drop-A" Messenger wire from drop cable to pole or φ1.2mm galvanized steel wire with sheath coating Detail "Drop-B" Detail "Drop-C" : S-Clamp (Japan) LEGEND : D-Clamp (Japan) : BW-Clamp (Local) FUSE-CONNECT ISC-UPC-FD ROSETTE RS-IN-SC-1P/ TC-MK-SC-1P Details of "Home Connect" ODP-SSW-8 ODP-PL/PW- 8/16 Drop Cable (Underground) GC-OF-SM-2D Wire Grip 3/8" with double nut
  • 41. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 41 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 4. CABLE RACK/OTB RACK IN STO BUILDING Note: 1. The cable routing in the STO building shall be measured so as to estimate the cable length from the duct entrance at the Cable Chamber until the OTB. 2. In case when the new rack shall be provided, the rack to be installed shall be of same type and the same color with the existing one. 3. In the decision of the location of 19” rack installation, well coordination with DBB, Telkom Area and/or WASPANG is required. 4. When the location of new 19” Rack installation is fixed, the designated location on the floor shall be clearly marked with an adhesive tape and a permanent marker as: “FTTH OSP JF DJAFa” 5. The maximum number of unit of TC-OF-SM-144 to be accommodated in the 19” Rack with Height of 2.20m shall be FIVE (5). CABLE CHAMBER MDF ROOM OTB ROOM/ TRANSMISSION ROOM 19”RACKH=2200 Max.5xTC-OF-SM-144 FEEDER CABLE STO BUILDING CABLE RACK
  • 42. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 42 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 5. HIGH-RISE BUILDING (HRB) DESIGN No. Designator Application No. of Splitter (Max.) Number of Port Home Pass Accommodated (80%)In Out Total 1. ODC for HRB/MDU (Approx.) 1.1 ODC-HRB-180 (*) Cabinet/ Wall 1:4 x 36 36 144 180 900 1.2 ODC-HRB-240 (*) Cabinet 1:4 x 48 48 192 240 1200 1.3 ODC-HRB-420 (*) Cabinet 1:4 x 84 84 336 420 2200 1.4 ODC-HRB-RACK-120 (**) 19" Rack Mount 1:4 x 24 24 96 120 600 1.5 ODC-HRB-RACK-240 (**) 19" Rack Mount 1:4 x 48 48 192 240 1200 1.6 ODC-HRB-RACK-480 (**) 19" Rack Mount 1:4 x 96 96 384 480 2500 2. ODP for HRB/MDU (Installed) (Max.) 2.1 ODP-HRB-16 (*) Wall Mount 1:8 x 1 - 8 8 16 1:8 x 2 - 16 16 2.2 ODP-HRB-32 (*) Wall Mount 1:8 x 3 - 24 24 32 1:8 x 4 - 32 32 3. 2-C Low Friction Indoor Cable 3.1 IC-OF-SM-1D Distribution/ Drop-core 1-Core (G657A) Low Friction Indoor Cable for DISTRIBUTION-CABLE 3.2 IC-OF-SM-2D 2-Core (G657A) Low Friction Indoor Cable for DROP-CABLE 1-Core connected with Fuse-Connect (ISC-UPC-FD), 1-Core for spare 4. ROSETTE SC Adapter 4.1 RS-IN-SC-1P 1 Indoor Rosette4.2 RS-IN-SC-2P 2 To be discussed when necessary (***) 4.3 RS-IN-SC-4P 4 To be discussed when necessary (***) 4.4 TC-MK-SC-1P 1 Indoor Rosette (Buried in wall) 4.5 TC-MK-SC-2P 2 To be discussed when necessary (***) 4.6 TC-MK-SC-4P 4 To be discussed when necessary (***) 5.1 MATERIAL FOR HRB SOLUTION Note (*): New Item (Specifications have been accepted by TELKOM) (**): New Item (Specifications shall be subject to concurrence by TELKOM) (***): To be discussed with DBB TELKOM when 2P or 4P Rosette is required by the Developer
  • 43. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 43 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 1-Core Low Friction Indoor Cable for 1x 1:8 Splitter with Field Installable SC Connector (Fuse-connect) x 1pc at both ends ODC-HRB- 1) 180 2) 240 3) 420 ODC-HRB-RACK- 1) 120 2) 240 3) 480 Feeder Cable: 1) For ODC-HRB-180: 24/48C 2) For ODC-HRB-240: 48C 3) For ODC-HRB-480: 96C ODP: 1) ODP-HRB-16: Up to 16 HP (1or 2 x 1:8 Splitter) Size: H=330 x W=260 x D=130 2) ODP-HRB-32: Up to 32 HP (3 or 4 x 1:8 Splitter) Size: H=412 x W=312 x D=140 ODP- HRB Cable Tray/Shaft/Ladder Rosette: TC-MK-SC-xP (1-Port/2-Port/4-Port) 2-Core Low Friction Indoor Cable with Field Installable SC Connector (Fuse-connect) x 1pc at both ends ODP- HRB 4) For ODC-HRB-RACK-120: 24C 5) For ODC-HRB-RACK-240: 48C 6) For ODC-HRB-RACK-480: 96C 5.2 DESIGN CONCEPT FOR HRB SOLUTION DESIGN CONCEPT FOR HRB 1. ODC shall be selected among all types according to the site situation as well as number of Home Pass of the target building. 2. ODP shall be selected among three (3) types according to the number of Home Pass and the Floor Layout. 3. 2-Core Low Friction Indoor Cable shall be used between ODC and ODP. 4. One (1) Low Friction Indoor Cable shall be connected ODC Port with one (1) 1:8 Splitter of ODP i.e.: 1) ODP-HRB-16: One (1) or two (2) Low Friction Indoor Cable: a. 1 x 1:8 Splitter: 1 Low Friction Cable b. 2 x 1:8 Splitter: 2 Low Friction Cables 2) ODP-HRB-32: Three (3) or four (4) Low Friction Indoor Cables: a. 3 x 1:8 Splitter: 3 Low Friction Cables b. 4 x 1:8 Splitter: 4 Low Friction Cables
  • 44. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 44 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 5.3 Type of ODC for High-Rise-Building 1) CABINET TYPE 2) RACK MOUNT TYPE (To be mounted in the Closed Rack H=1.20m) H= 770 W=555 D=310 ODC-HRB-180 Application: Wall/Floor D=360 H= 1450 W=750 ODC-HRB-240/420 Application: Floor W=428 H= 275 D=302.3 ODC-HRB-RACK-120 Application: 19" Rack W=428 D=302.3H= 445 ODC-HRB-RACK-240 Application: 19" Rack W=428 D=302.3 H= 890 ODC-HRB-RACK-480 Application: 19" Rack
  • 45. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 45 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 5.4 Example of Cable Tray/Trunking 1) HORIZONTAL RUN (a) On the Cable Tray Cable Tray Cable Trunking (b) Direct Attachment to the Building Wall 2) VERTICAL RUN ODP- HRB Elbow (Flat Angle) T-Joint Cable Trunking
  • 46. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 46 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 5.5 SAMPLE DESIGN: SKEMA DISTRIBUSI ODC ABC BUILDING F.../STO/HRB-xxx xx PS 1:4 (xxx HP) S 6 E 106 ... x IC-OF-SM-1D __m x IC-LF-OF-SM-1D __m x IC-OF-SM-1D __m 2 IC-OF-SM-1D__m x IC-LF-OF-SM-1D __m 1 IC-LF-OF-SM-1D __m 2 IC-OF-SM-1D __m x IC-OF-SM-1D __m x IC-OF-SM-1D __m F /P01-02/1/2 ODP-HRB-16 F /P03/2/1 ODP-HRB-16 (Note: Not "8") ODC No. Code STO "HRB"-"Capacity" 180 240 420 No. of Splitter No. of Home Pass No. of Splitter 1:8 ODP No. ODC Port No. Each No. to be given for Each 1-Core Indoor CableODC No. Specify "Tower" and/or "Shaft" according to the Building Layout. F /P04-05/3/2 ODP-HRB-16 2: No. of Indoor Cable to be installed and terminated to ODP __m: Cable Length from ODC to ODP Tower A/ Shaft No.1 Floor-xx Floor-yy Floor-zz Descriptions for ODC 1.1.1.1.ODC XXX (Name of Building) 2. F... /STO /HRB-(RACK)-xxx 3. xx PS 1:4 (xxx HP) 4. Coordinates 1. F / P-03/ 2/ 1 Descriptions for ODP 2. ODP-HRB-xx Type of ODP: ODP-HRB-16, 32 (See Note above.) Note: Type of ODP-HRB is 2: 1. ODP-HRB-16: No. of 1:8 Splitter= 1 or 2 2. ODP-HRB-32: No. of 1:8 Splitter= 3 or 4
  • 47. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 47 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 5.6 SAMPLE DESIGN: PETA LOKASI DISTRIBUSI 1) PETA LOKASI KABEL DISTRIBUSI (Vertical View) Tower A F /P03/2/1 ODP-HRB-16 Note: Not "8" F /P04-05/3/2 ODP-HRB-16 ODC ABC BUILDING F.../STO/HRB-xxx xx PS 1:4 (xxx HP) F /P01-02/1/2 ODP-HRB-16 Cable Shaft No.1 Cable Shaft No.2 Cable Tray/Trunking to be installed e.g. Cable Tray W=100mm x 35m 1 LEGEND : ODC-HRB : ODP-HRB : Cable Tray/Trunking (New) 2 : Rosette (1-Port) : Rosette (2-Port) : Cable Tray/Trunking (Existing)
  • 48. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 48 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 2 31 LIFT 11 4 5 6 7 8 9 10 19 31 22 32 33 34 35 36 37 38 3930 18 23 17 24 16 25 15 26 14 27 13 28 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 12 20 2129 F /P01-02/1/2 ODP-HRB-16 F /P03/2/1 ODP-HRB-16 Note: Not "8" F /P04-05/3/2 ODP-HRB-16 2) PETA LOKASI DROP-CORE (Floor Plan)
  • 49. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 49 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N Table-1: List of Port Management ODC Port No. Distribution Cable No. ODP Unit No. Drop Cable Length (m)No./Floor Splitter No. Port 1 D01 8 1 1 1 30.0 2 2 18.0 3 3 10.0 4 25 55.0 5 26 50.0 6 27 45.0 7 28 40.0 8 29 35.0 2 D02 2 1 11 12 30 31 32 33 34 35 6 7 8 3) LIST OF PORT MANAGEMENT & DROP-CORE LENGTH
  • 50. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 50 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
  • 51. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 51 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 6.1 PONDASI ODC-C-144 Splitter Keterangan: Pondasi dan lantai kerja berlapis keramik. 1. Pondasi: Keramik 20 x 20, warna biru 2. Lantai kerja: Keramik 20 x 20 Non-slip, warna biru 310mm 1035mm 555mm 463 170 500600 660 360150 150 ODC Foundation: A-A (Not to scale/ Unit: mm) 98.5 98.5 75 – 85mm Drill:Ф14mm/ d= 75 – 85mm (Expansion Bolt: M8 x 150) 1100 463 G.L 52.5 52.5555 ODC Foundation: B-B (Not to scale/ Unit: mm) 440 150 150140 115 115170 75 – 85mm Drill:Ф14mm/ d= 75 – 85mm (Expansion Bolt: M8 x 150) G.L 31065 65 ODC Foundation: Top View (Not to scale/ Unit: mm) 150150140 440 150 150360 660 440 135135170 660 98.5 98.5 463 Drill:Ф14mm/ d= 75 – 85mm A A B B (Expansion Bolt: M8 x 150) ODC Foundation Conduit Connection (Not to scale/ Unit) R > 500mm W=600 (HH-2) Handhole Type:HH2 5 x HDPE 33/40 (B-B Side) Approx.30cm or less Approx. 30cm G.L. - 200 ± 0 - 1500 - 1000 Handhole Type:HH-80 W=800 (HH-80) - 600 Special Attention: Cable Slack shall be placed only in HANDHOLE/HH-PIT and never be located in the ODC Foundation.
  • 52. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 52 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 6.2 PONDASI ODC-C-288 Splitter 150150140 440 165 165520 850 440 120120200 850 119 119612 Drill:Ф18mm/ d= 60 – 80mm ODC Foundation: Top View (Not to scale/ Unit: mm) A A B B (Expansion Bolt: M12 x 150) 320mm 1450mm 750mm ODC Mount and Location of Anchor Bolt 612 200 ODC Foundation: A-A (Not to scale/ Unit: mm) G.L 500600 850 520165 165 119 119 60 – 80mm Drill:Ф18mm/ d= 60 – 80mm (Expansion Bolt: M12 x 150) 1100 612 50 50750 Keterangan: Pondasi dan lantai kerja berlapis keramik. 1. Pondasi: Keramik 20 x 20, warna biru 2. Lantai kerja: Keramik 20 x 20 Non-slip, warna biruODC Foundation: B-B (Not to scale/ Unit: mm) 440 150 150 120 120200 60 – 80mm Drill:Ф18mm/ d= 60 – 80mm (Expansion Bolt: M12 x 150) G.L 60 60320 140 Conduit Connection (Not to scale/ Unit) R > 500mm W=600 (HH-2) Handhole Type:HH2 5 x HDPE 33/40 (B-B Side) Approx.30cm or less Approx. 30cm G.L. - 200 ± 0 - 1500 - 1000 Handhole Type:HH-80 W=800 (HH-80) - 600 ODC Foundation Special Attention: Cable Slack shall be placed only in HANDHOLE/HH-PIT and never be located in the ODC Foundation.
  • 53. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 53 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 500 100 300 100 TELKOM 500 100100 300 Ф 300 PVC 4" Sub-duct BIG 500 700 200150150 100100 Distance in accordance with the site situation. Jarak sesuai kondisi lapangan. 150 150400 700 900 100 100 Sub-duct BIG PVC 4" PVC 4" for Drop Cable L=300 PVC 4" for Distribution Cable L=300 450150 900 600150 150 150 600 150 900 700 150 500 200150 150 100 100 150 100 80220 H(*)600-H 600 500 100 100Ф 300 150 150400 700 LARGE RADIUS ELBOW PVC 4" (WAVIN D-LL 4" or Equivalent) PVC4"L=±650 Distance in accordance with the site situation. Jarak sesuai kondisi lapangan. 6.3 PONDASI ODP PEDESTAL & HH-PIT-60 Cable Installation Method between HH-PIT-60 and ODP Distribution Cable Installation shall cautiously be carried out so that the Bending Radius of 20cm shall be secured. Note “H”: Height above ground shall be minimum 10cm. Actual height shall be in accordance with the site condition.
  • 54. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 54 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 1300 250150900 250 1000 1250 288-C cable R= 44.2mm +- 150cm 557mm 450625 625 1700 1300 250150+-90cm 450625 625 PASS-THROUGH CLOSURE ARRANGEMENT IN HH-1 (288-C Loose Tube Cable / 3M Type 2178LS) BESI 70 x 50 x 3 150 1501250 1550 100 1001350 200 200950 1550 Hole Ф20mm Ф10mm x 125mm POT B - B Ф12mm x 125mm PVC Ф4" x 4 L= 300 1 5 0 1 5 0 1 5 0 1 5 0 Ф10mm x 125mm BETON: 225kg/cm² 150 1501700 2000 2001501300 1650600 600100 100 200 200 200200 200 200 Ф10mm x 125mm Ф10mm x 125mm POT A - A 600 200 200 200 Ф12mm x 125mm 150150 L=300 T E L K O M T E L K O M T E L K O M 150150150950 1550 A A B B 100200200200 200 200200 2000 200 200100 1350 3 x 600 = 1800 150 TELKOM 200 TELKOM TELKOM 6.4 HH-1: Dimensi Dalam (P=1700 x L=1250 x T=1300)
  • 55. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 55 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N BESI 70 x 50 x 3 150 150600 900 100 100700 150 150400 900 Hole Ф20mm Ф10mm x 125mm POT B - B PVC Ф4" x 4 L= 300 150 150150 150 T E L K O M 100 225 225 100200 225225 200 1500 150150150300 900 A A B B T E L K O M 2 x 650 = 1300 700 150 PVC Ф4" x 4 L= 300 150 1501200 1500 2001501300 1650 650 650100 100 225 200 225225 200 225 150 Ф10mm x 125mm Ф10mm x 125mm POT A - A 150 L=300 6.5 HH-2: Dimensi Dalam (P=1200 x L=600 x T=1300) BETON: 225kg/cm²
  • 56. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 56 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 6.6 HH-80: Dimensi Dalam (P=800 x L=800 x T=800) 150150 800 1100 150 Ф10mm x 125mm Ф10mm x 125mm 200150800 1150100 200 450 1100 125 150 L=300 450 100 125 200125 125 POT A - A Hole Ф20mm 150 150150 PVC Ф4" x 4 L= 300 BESI 70 x 50 x 3 Ф10mm x 125mm 150 150 800 1100 200150800 1150 1100 100 100900 150 150600 150 POT B - B B T E L K O M 1100 150 100 1100 A A B 1100 PVC Ф4" x 4 L= 300 900 T E L K O M 150 100 600 100 125 100 200 450 1100 450 125 125 200 125 BETON: 225kg/cm²
  • 57. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 57 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N G.L. Approx.2.20m 10cm 30cm 10c m 30cm Approx. 10cm Clampsshallbeattached Approx.@<1.0m ClampsshallbeattachedApprox. @<1.0m Gap between steel pipe (Ф 2") and ODP (Wall Mount) shall be less than 10cm Galvanized Steel Pipe (Ф2") and Clamps shall be painted with the same color with the wall. Approx. 10cm Approx. 10cm Approx. 10cm B (See detail.) A (See detail.) Approx. 5cm Gap between steel pipe (Ф 2") and ODP (Wall Mount) shall be less than 10cm Identification Marking (White color) shall be applied on the cable of "Up-stream/ODC" side. In case Gap between steel pipe (Ф 2") and ODP (Wall Mount) is more than 5cm, cables shall be protected with spiral or flexible pipe (Black color) HDPE Pipe 33/40 Ф 2" Galvanized Steel Pipe Details "A" 30cm 10cm20cm 30cm 30cm G.L. HDPE 33/40 shall be installed until the level with Galvanized Steel Pipe.. Details "B" 6.7 INSTALLATION OF ODP WALL (1)
  • 58. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 58 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N Flex. Pipe OD=25mm Steel flexible inside HH PIT-60 150 Flex-pipe R≧300 Approx. 200 Appro x. 100 Approx. 100 Approx. 100 Flex-pipe R≧300 Flex-pipe R≧300 Flex-pipe R≧300 Flex-pipe R≧300 PVC Simple Socket for OD 25mm Pipe PVC/High-Impact Conduit OD Ф25mm PVC/High-Impact Conduit OD Ф25mm Pipes shall be buried in the wall. Pipe space shall be filled with concrete after ODP installation. 150 Approx. 200 100 50 Approx. 100 HH PIT-60 Note: In case when pipes shall be buried in the building wall due to the requirement by the developer, the following points shall be taken into account for the installation. 1. HH-PIT-60 shall be installed in front of ODP location. 2. Flexible Pipe with steel (OD 25mm) shall be used at the bending part of conduit. 3. Bending Radius of Flexible Pipe shall be more than 300mm. 4. PVC/High-Impact Pipe (OD 25mm) shall be used at the straight part of conduit. 5. PVC Simple Socket for OD 25mm Pipe shall be used at all jointing part. 6. Pipe space of wall shall be filled with concrete after installation of ODP. (ODP termination work shall be done prior to the pipe fixing and concrete work.) 7. The wall shall be restored to the original condition and painted with the same color with the original wall. MOM/BA shall be made (to be signed by the PIC of the developer) for the confirmation of the requirement. 2 x PVC Ф50 (L=200) Pipes shall be buried in the wall. Pipe space shall be filled with concrete after ODP installation. Drop Cable 6.7 INSTALLATION OF ODP WALL (2) (In case pipe shall be buried in the wall)
  • 59. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 59 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 6.8 FORM FOR CORE ASSIGNMENT 6.8.1 FEEDER CABLE (STAR TOPOLOGY: 24 CORE BASE)
  • 60. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 60 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 6.8.2 FEEDER CABLE (STAR TOPOLOGY: 12 CORE BASE)
  • 61. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 61 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 6.8.3 FEEDER CABLE (RING TOPOLOGY)
  • 62. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 62 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 6.8.4 DISTRIBUTION CABLE No. Port No. PORT No. CORE ASSIGNMENT DIAGRAM (DISTRIBUTION CABLE) CAPACITY -CORE OTB Port No. SPLITTER 1:4 CORE No. ODC PORT No. ODC TRAY DISTRIBUTION CABLE No. 4 3 4 1 2 D- 2 3 4 1 2 3 4 1 2 3 3 4 1 2 3 4 1 2 1 19 20 21 22 23 24 13 14 15 16 17 18 7 8 9 10 11 12 1 2 3 4 5 6 FEEDER SEGMENT 1 2 3 4 1 2 3 4 5 6 7 8 9 10 STO 11 12 5 6 7 8 DISTRIBUTION SEGMENT ODP No.ODP No.ODP No.ODP No. NAMA LOKASI 9 10 11 12
  • 63. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 63 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N TipeProduct:ODC-C-144 Tgl.Instalasi NamaLokasi NamaInstaller CategoryItems 1.AksesorisCableband(M) Cableband(L) SpiralTube Compound Cabletie Assemblymanual PVCtape 2.PondasiODCBautexpansiontidakkendur 3.LubangKabelMasuk(Feeder&Distribusi) 4.CableclampClampuntuktensionMembertidakkendur CableBandtidakKendur 5.RuteLooseTubeTidakadasmallbending(diameter>60) tidakterjepitdengantutuptray Tidakadasmallbending(diameter>60) tidakterjepitdengantutuptray 7.RutePigtaildalamTrayArahRute(bentukS) Tidakadasmallbending(diameter>60) tidakterjepitdengantutuptray 8.InstalasiSplittermodul rutesesuaipetunjukmanual Tidakadasmallbending(diameter>60) tidaksalingtersangkutdanmudahdiurai 10.SCconnectorpatchingKonektortercolokdenganbenar(sampaibunyiklik) diperiksaoleh: (Sitemanager) Catatan ArahdanPosisiSplitterharusbenar(Input:bawah; Output:atas) PenggunaanCompoundharusrapat(tidakadacelah) InstallationCheckSheet pcs pcs pcs pc pcs 9.RutekabeldariSplitterkeTray pc pc Check *2buahkunciODCharussudah diterimasitemanager *ceksisaaksesorisyangdiperlukan untukinstalasikabelberikutnyadanuntuk maintenance 6.RuteFiberdidalamTray 6.9 INSTALLATION CHECK SHEET 6.9.1 INSTALLATION CHECK SHEET: ODC-C-144
  • 64. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 64 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 6.9.2 INSTALLATION CHECK SHEET: ODC-C-288 TipeProduk:ODC-C-288 Tgl.Instalasi NamaLokasi NamaInstaller CategoryItems 1.AksesorisCableband(M) Cableband(L) SpiralTube Compound Cabletie Assemblymanual PVCtape 2.PondasiODCBautexpansiontidakkendur 3.LubangKabelMasuk(Feeder&Distribusi) 4.CableclampClampuntuktensionMembertidakkendur CableBandtidakKendur 5.RuteLooseTubeTidakadasmallbending(diameter>60) tidakterjepitdengantutuptray Tidakadasmallbending(diameter>60) tidakterjepitdengantutuptray 7.RutePigtaildalamTrayArahRute(bentukS) Tidakadasmallbending(diameter>60) tidakterjepitdengantutuptray 8.InstalasiSplittermodul rutesesuaipetunjukmanual Tidakadasmallbending(diameter>60) tidaksalingtersangkutdanmudahdiurai 10.SCconnectorpatchingKonektortercolokdenganbenar(sampaibunyiklik) Diperiksaoleh (Sitemanager) Catatan ArahdanPosisiSplitterharusbenar(Input:kiri; Output:kanan) *2buahkunciODCharussudah diterimasitemanager InstallationCheckSheet Check pcs pcs pcs pc pcs *ceksisaaksesorisyangdiperlukan untukinstalasikabelberikutnyadanuntuk maintenance 6.RuteFiberdidalamTray 9.RutekabeldariSplitterkeTray pc pc PenggunaanCompoundharusrapat(tidakada celah)
  • 65. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 65 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N ProductType:ODP-CA-8/16-WP InstallationDate: InstallationSite: InstallerName: CategoryItemsCheck 1.AccessoryCabletiepcs Expansionscrewsets Dropcablefixingclamppcs Bukumanualpc PVCtapepc 2.InstalasiSplitterArah:input:kiri;output:kanan,labelterlihat PosisiSplitter:No1palingatas Tidakadasmallbending(diameter>60) KabelTidakterjepitatautersangkutjikadibuka PosisiKonektor 4.LubangTempatkabelmasuk 5.clampKabelClampuntukTensionmemberTidakkendur Clampuntukkabeltidakkendur 6.RutekabelSCPTPassthroughTidakadasmallbending(diameter>60) TidakterjepitdantersangkutjikaODPdibuka 7.ClampdanruteSCPTyangditerminasipastikanpenggunaankabelTiesditigatitik Tidakadasmallbending(diameter>60) tidakterjepitdantersangkutjikaODPdibuka 8.RuteFibersetelahSplicingTidakadasmallbending(diameter>60) tidakterjepitdantersangkutjikaODPdibuka Diperiksaoleh: (Sitemanager) Catatan pemasangantempatmasukkabelharusrata,tidakmiring InstallationChecksheet *1buahkunciODPharussudah diterimasitemanager tidakadacelah(penggunaansolasiataugrommet harusdapatmenutupcelah) adadisebelahkanan, BariskonektorpalingbawahuntukSplitterno.1 *ceksisaaksesorisyangdiperlukan untukinstalasikabelberikutnyadanuntuk maintenance 3.instalasioutputSplitterpadapanel Adapter 6.9.3 INSTALLATION CHECK SHEET: ODP-PL/PW-8/16
  • 66. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 66 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N ProductType:TC-SM-144 InstallationDate: InstallationSite: InstallerName: CategoryItems 1.AksesorisCableband(M) Cableband(L) PlasticTube Screwandnut Cabletie BukuManual PVCtape 2.ClampkabelClampuntukTensionmemberTidakkendur CableBandtidakkendur 3.RutekabelLoosetubeTidakadasmallbending(diameter>60) kabelTidakterjepitatautersangkutjikatraydilepas Tidakadasmallbending(diameter>60) Tidakterjepitatautersangkutjikacovertraydibuka 5.RutePigtailpadaTrayRutemembentukhurufS Tidakadasmallbending(diameter>60) TidakTerjepitatautersangkutjikacovertraydibuka Diperiksaoleh (Sitemanager) Catatan pc pc Check 4.Rutekabeldalamtray *Ceksisaaksesorisyangdiperlukan untukinstalasikabelberikutnyadanuntuk maintenance InstallationCheckSheet pcs pcs pcs sets pcs 6.9.4 INSTALLATION CHECK SHEET: TC-SM-144
  • 67. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 67 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 6.10 LIST OF ASSEMBLY UNIT DESIGNATOR (1/6) AKABEL&PENYAMBUNGAN 1DC-OF-SM-12D PengadaandanpemasanganKabelDuctFiberOptik SingleMode12coreG652D(termasukperijinan PEMDA,PU,Warga) meter 2DC-OF-SM-24DIdem24coremeter 3DC-OF-SM-48DIdem48coremeter 4DC-OF-SM-96DIdem96coremeter 5DC-OF-SM-144DIdem144coremeter 6DC-OF-SM-288DIdem288coremeter 7DC-OF-SM-432DIdem432coremeter 8DC-OF-SM-960DIdem960coremeter 9AC-OF-SM-12D PengadaandanpemasanganKabelUdaraFiber OptikSingleMode12coreG652D(termasuk perijinanPEMDA,PU,Warga) meter 10AC-OF-SM-24DIdem24coremeter 11AC-OF-SM-48DIdem48coremeter 12AC-OF-SM-96DIdem96coremeter 13DC-OF-SM-12C PengadaandanpemasanganKabelDuctFiberOptik SingleMode12coreG655C(termasukperijinan PEMDA,PU,Warga) meter 14DC-OF-SM-24CIdem24coremeter 15DC-OF-SM-48CIdem48coremeter 16DC-OF-SM-96CIdem96coremeter 17AC-OF-SM-12C PengadaandanpemasanganKabelUdaraFiber OptikSingleMode12coreG655C(termasuk perijinanPEMDA,PU,Warga) meter 18AC-OF-SM-24CIdem24coremeter 19AC-OF-SM-48CIdem48coremeter 20AC-OF-SM-96CIdem96coremeter 21DC-OF-SM-8-SC PengadaandanpemasanganKabelDuctFiberOptik SingleMode8coreG652D,"Easytosplit" (termasukperijinanPEMDA,PU,Warga) meter 22DC-OF-SM-12-SCIdem12Coremeter 23DC-OF-SM-24-SCIdem24Coremeter 24AC-OF-SM-8-SC PengadaandanpemasanganKabelUdaraFiber OptikSingleMode8coreG652D,"Easytosplit" (termasukperijinanPEMDA,PU,Warga) meter 25AC-OF-SM-12-SCIdem12Coremeter 26AC-OF-SM-24-SCIdem24Coremeter 27SC-OF-SM-24 Pengadaandanpemasanganalatsambung(cabang/ lurus)untukFiberOptikkapasitas12-24core pcs 28SC-OF-SM-48Idem12-48corepcs 29SC-OF-SM-96Idem12-96corepcs 30SC-OF-SM-144Idem12-144corepcs 31SC-OF-SM-288Idem12-288corepcs 32OS-SM-1Eks PenyambunganKabelOptikSingleModekap1core dengancarafusionsplice core 33OS-SM-6 PenyambunganKabelOptikSingleModekap6core dengancarafusionsplice pcs 34OS-SM-12Idemkap12corepcs 35OS-SM-24Idemkap24corepcs 36OS-SM-48Idemkap48corepcs 37OS-SM-96Idemkap96corepcs 38OS-SM-144Idemkap144corepcs 39OS-SM-288Idemkap288corepcs 40AB-OF-SM-2D PengadaandanpemasanganAirBlownCableOptik, SingleMode2core,G652D(termasukperijinan PEMDA,PU,Warga) meter 41AB-OF-SM-4DIdem4coremeter 42AB-OF-SM-8DIdem8coremeter 43AB-OF-SM-12DIdem12coremeter 44AB-OF-SM-24DIdem24coremeter 45AB-OF-SM-48DIdem48coremeter 46AB-OF-SM-72DIdem72coremeter 47AB-OF-SM-96DIdem96coremeter 48AB-OF-SM-144DIdem144coremeter 49GC-OF-SM-1D PengadaandanpemasanganDropCableFODuct /underground1CoreSingleMode,G.657 meter 50GC-OF-SM-2Didem2core 51HC-OF-SM-1D PengadaandanpemasanganDropCableFOatas tanah/aerial1CoreSingleMode,G.657 meter 52HC-OF-SM-2Didem2coremeter 53IC-OF-SM-1D PengadaandanpemasanganIndoorCableFOSingle Mode1core,G.657 meter 54IC-OF-SM-2DIdem2coremeter KETERANGANNODESIGNATORURAIANPEKERJAANSATUAN
  • 68. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 68 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 6.10 LIST OF ASSEMBLY UNIT DESIGNATOR (2/6) 55PC-SC-2-BI Patchcord2meter,BendInsensitive(SC/APCTo SC/UPC)dariRosetkeONT,G.657 pcs 56PC-SC-5-BI Patchcord5meter,BendInsensitive(SC/APCTo SC/UPC)dariRosetkeONT,G.657 pcs 57PC-SC-2Patchcord2meter,(SC/APCToSC/APC),G.657pcs 58PC-SC-5Patchcord5meter(SC/APCToSC/APC),G.657pcs 59PC-SC-10Patchcord10meter(SC/APCToSC/APC),G.657pcs 60PC-SC-20Patchcord20meter(SC/APCToSC/APC),G.657pcs 61PC-FC-20Patchcord20meter(FC/APCToFC/APC),G.657pcs 62PC-SC-30Patchcord30meter(SC/APCToSC/APC),G.657pcs 63PC-FC-30Patchcord30meter(FC/APCToFC/APC),G.657pcs 64PC-SC-40Patchcord40meter(SC/APCToSC/APC),G.657pcs 65PC-FC-40Patchcord40meter(FC/APCToFC/APC),G.657pcs 66PC-SC-2Patchcord2meter,(SC/UPCToSC/UPC),G.657pcs 67PC-SC-5Patchcord5meter(SC/UPCToSC/UPC),G.657pcs 68PC-SC-10Patchcord10meter(SC/UPCToSC/UPC),G.657pcs 69PC-SC-20Patchcord20meter(FC/UPCToFC/UPC),G.657pcs 70PC-FC-20Patchcord20meter(SC/UPCToSC/UPC),G.657pcs 71PC-SC-30Patchcord20meter(FC/UPCToFC/UPC),G.657pcs 72PC-FC-30Patchcord30meter(SC/UPCToSC/UPC),G.657pcs 73PC-SC-40Patchcord40meter(FC/UPCToFC/UPC),G.657pcs 74PC-FC-40Patchcord40meter(SC/UPCToSC/UPC),G.657pcs 75PC-FC-40Patchcord40meter(FC/UPCToFC/UPC),G.657pcs 76ODC-C-144Splitter PengadaandanpemasangankabinetODC(Outdoor) kap144coredenganspaceuntuksplitermodular termasukmaterialadaptorSC/UPC,pigtail,pondasi berlapiskeramik,lantaikerja,patokpengaman(5 buah),berikutpelabelan pcs 77ODC-C-288Splitter PengadaandanpemasangankabinetODC(Outdoor) kap288coredenganspaceuntuksplitermodular termasukmaterialadaptorSC/UPC,pigtail,pondasi berlapiskeramik,lantaikerja,patokpengaman(5 buah),berikutpelabelan pcs 78ODC-C-576Splitter PengadaandanpemasangankabinetODC(Outdoor) kap576coredenganspaceuntuksplitermodular termasukmaterialadaptorSC/UPC,pigtail,pondasi berlapiskeramik,lantaikerja,patokpengaman(5 buah),berikutpelabelan pcs 79ODC-C-48Splitter PengadaandanpemasanganODC-Pole(Outdoor) withspaceforpassivespliter,adaptorSC/UPCkap 48core,berikutpelabelan pcs 80ODP-CU-8 PengadaandanpemasanganODPtypeClosure UndergroundKap8corewithspaceforsplitter, AdapterSC/UPC pcs 81ODP-CU-16idem16corepcs 82ODP-CA-8 PengadaandanpemasanganODPtypeClosure AerialKap8coreberikutspacepasivespliter(1:8), adapterSC/UPC,berikutpelabelan pcs 83ODP-CA-16 PengadaandanpemasanganODPtypeClosure AerialKap16coreberikutspace2pasivespliter (1:8),adapterSC/UPC,berikutpelabelan pcs 84ODP-A-8 PengadaandanpemasanganODPtypeIndoor/wall Kap8coreberikutspacepasivespliter(1:8),adapter SC/UPC,berikutpelabelan pcs 85ODP-A-16 PengadaandanpemasanganODPtypeIndoor/wall Kap16coreberikutspace2pasivespliter(1:8), adapterSC/UPC,berikutpelabelan pcs 86ODP-A-24 PengadaandanpemasanganODPtypeIndoor/wall Kap24coreberikutspace3pasivespliter(1:8), adapterSC/UPC,berikutpelabelan pcs 87ODP-A-48 PengadaandanpemasanganODPtypeIndoor/wall Kap48coreberikutspace6pasivespliter(1:8), adapterSC/UPC,berikutpelabelan pcs 88ODP-PL-8 PengadaandanpemasanganODP(Pilar)kap8 coretermasukpigtail,berikutspace1splitter(1:8), pelabelan. pcs 89ODP-PL-16 PengadaandanpemasanganODP(Pilar)kap16 coretermasukpigtail,berikutspace2splitter(1:8), pelabelan. pcs KETERANGANNODESIGNATORURAIANPEKERJAANSATUAN
  • 69. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 69 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 6.10 LIST OF ASSEMBLY UNIT DESIGNATOR (3/6) 90TC-SM-12 PengadaandanPemasanganOTBtermasuk terminasidanpenyambungankabeloptikSingle modekap12coresertaAdapter(SCConnector), pigtaildanprotectionsleevepadacassette/box pcs 91TC-SM-24Idem24corepcs 92TC-SM-48Idem48corepcs 93TC-SM-72Idem72corepcs 94TC-SM-96Idem96corepcs 95TC-SM-144Idem144corepcs 96RS-IN-SC-1P PemasangandanterminasiRoset/IndoorOptical OutletwithSCAdaptor-kap1portberikutpigtail pcs 97RS-IN-SC-2Pidem2portpcs 98RS-IN-SC-4Pidem4portpcs 99TC-MK-SC-1P RosetOptikModularKeystone(Ditanamditembok) denganSCAdaptorkap1port unit 100TC-MK-SC-2Pidem2portunit 101TC-MK-SC-4Pidem4portunit 102PS-1-2-ODC PengadaandanpemasanganPassiveSplitter1:2, typemodular,forODC,termasukpigtail pcs 103PS-1-4-ODCIdem,1:4pcs 104PS-1-8-ODCIdem,1:8pcs 105PS-1-16-ODCIdem,1:16pcs 106PS-1-32-ODCIdem,1:32pcs 107PS-1-2-ODP PengadaandanpemasanganPassiveSplitter1:2, typePLC/Modular,forODP,termasukadaptor pcs 108PS-1-4-ODPIdem,1:4pcs 109PS-1-8-ODPIdem,1:8pcs 110PS-1-16-ODPIdem,1:16pcs 111PS-1-32-ODPIdem,1:32pcs 112PS-2-2-ODC PengadaandanpemasanganPassiveSplitter2:2, typemodular,forODC,termasukpigtail pcs 113PS-2-4-ODCIdem,2:4pcs 114PS-2-8-ODCIdem,2:8pcs 115PS-2-16-ODCIdem,2:16pcs 116PS-2-32-ODCIdem,2:32pcs 117PS-2-2-ODP PengadaandanpemasanganPassiveSplitter2:2, typePLC/Modular,forODP,termasukadaptor pcs 118PS-2-4-ODPIdem,2:4pcs 119PS-2-8-ODPIdem,2:8pcs 120PS-2-16-ODPIdem,2:16pcs 121PS-2-32-ODPIdem,2:32pcs 122SITACODCAkuisisiLahanSITACODCNode 123PU-S7.0-140 PengadaandanPemasanganTiangBesi7meter, berikutcat&corpondasidanassesories-kekuatan tarik140kg pcs 124PU-S9.0-140 PengadaandanPemasanganTiangBesi9meter, berikutcat&cordanassesories-kekuatantarik140 kg pcs 125PU-C9.0-300 PengadaandanPemasanganTiangBeton9meter, berikutassesories 126GU-GPengadaandanPemasanganTemberangTarikpcs 127PU-SB-7.0-140 Pengadaandanpemasangantemberangsokong7 meter,kekuatantarik140kg pcs 128PU-ASAsesoristiangeksistingset 129GB-G1 PengadaandanPemasanganGrounding1titikrod padaODP/kotakpembagidenganmaks3ohm pcs 130GB-G3 PengadaandanPemasanganGrounding3titikrod padaODCdenganmaks1ohm pcs 131GroundingdiEksisting PengadaandanPemasanganmaterialGroundingdi lokasigedungeksistingdengancaraintegrasi pcs 132TC-XX-ODC PengaddaandanPemasanganRisePipeuntuk pengamankabeloptikkeODCPole/titiknaikKU diamater1panjang3meter pcs 133TC-OF-R-19 Pengadaandanpemasanganrakkabel19inchuntuk FiberOptikClosedRack,2,2Mtr pcs 134FLEX-PIPE PengadaandanpemasanganFlexiblepipe(pipa spiral)ukuran1.5inchtermasukaksesoris. meter KETERANGANNODESIGNATORURAIANPEKERJAANSATUAN
  • 70. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 70 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 135PP-OF-IN PengadaandanPemasanganPipeProtectorIndoor Cable(PVCWhite)HighImpactConduit20mm meter 136PP-OF-OUT PengadaandanPemasanganPipeProtector OutdoorCable(PVCBlack)HighImpactConduit20 mm meter 137TC-OF-DC-10 PengadaandanpemasanganDuctCableuntuk RouteKabelmenujuRoset,10x20mm meter 138TC-OF-DC-20idem20x40mmmeter 139TC-OF-CR-100 PengadaandanpemasanganTrayCable,Lebar100 mmtebal5mmAlumuniumdisesuaikankebutuhan meter 140TC-OF-CR-200idem200mmmeter 141TC-OF-CR-300idem300mmmeter 142DD-S3-1 PengadaandanpemasanganPipaBesiDiameter Dalam100mmdanketebalanpipa3,65mmuntuk crossing1pipa meter 143DD-S3-2 PengadaandanpemasanganPipabesidiameter dalam100mmdanketebalanpipa3,65mmuntuk crossing2pipa meter 144DD-S3-3 PengadaandanpemasanganPipabesidiameter dalam100mmdanketebalanpipa3,65mmuntuk crossing3pipa meter 145DD-V4-1 PengadandanPemasanganPipaDuctdengan pengecorandiameterdalam100mm,ketebalan4 mm,1pipa meter 146DD-V4-2Idem,2pipameter 147DD-V5-1 PemasanganPipaDuctdenganpasirdia100mm,1 pipa(crossing) meter 148DD-V5-2Idem,2pipameter 149DD-DA-S1 PengadaandanpemasanganpipaDuctmenempel padajembatanmenggunakanPipaGalvanis diamenterdalam100mm,tebal3,65mm,1pipa meter 150DD-BSS-S1 PengadaandanpemasanganpipaDuctpada jembatandenganmenempelmenggunakanPipabesi Galv1pipa(Parit) meter 151DD-BTS-S1 PengadaandanpemasanganPipaDuctdengan penguatsendiri1pipa meter 152DD-BTS-S2 PengadaandanpemasanganPipaDuctdengan penguatsendiri2pipa meter 153HB-PS-1 PengadaandanpemasanganPipaDuctdengan systemgantung1pipabentangs/d40meter meter 154HB-PS-2 PengadaandanpemasanganPipaDuctdengan systemgantung2pipabentanglebih40meter meter 155DD-BMR BoringpadaLintasanKeretaApimenggunakan2 pipa track 156DC-SD-1 PengadaandanPemasangan1Subduct27/32mm padapolonganrouteDuct meter 157DC-SD-3 PengadaandanPemasangan3Subduct27/32mm padapolonganrouteDuct meter 158DC-SD-1Big PengadaandanPemasangan1SubductBigpada polonganrouteDuct meter 159DC-SD-2Big PengadaandanPemasangan2SubductBigpada polonganrouteDuct meter 160DCD-PVC-1 PembuatanDuctCableDistribusidiameterpipaPVC 2incAW1pipa meter 161DCD-PVC-2idem2pipameter 162DCD-PVC-4idem4pipameter 163DD-BM-1 PemasanganPipaDuctdengancaraboringmanual /mesin1pipa meter 164DD-BM-2Idem2pipameter 165DD-BM-HDPE-1 Boringmanual/mesinuntukHDPE/MicroDuct diameterdalam33mm1pipakedalaman1,5meter meter 166DD-BM-HDPE-2Idem,2pipameter 167DD-HDPE-1 PengadaandanPemasangan1pipaHDPE/HDPE BIGuntukkabelFO,IncludeSoketHDPE meter 168DD-HDPE-2Idem2pipa 169DD-ROD PembersihanpadarouteDuctyangkosong/Rodding DuctExisting. meter 170DD-RV-1PerbaikanRouteDuct/HDPE,1pipa.meter KETERANGANNODESIGNATORURAIANPEKERJAANSATUAN 6.10 LIST OF ASSEMBLY UNIT DESIGNATOR (4/6)
  • 71. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 71 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 6.10 LIST OF ASSEMBLY UNIT DESIGNATOR (5/6) 171DD-RV-CONCRETE RelocatedanExspandPipainCounterWallbyBobok Concrete m3 172BC-TR-0.4 Galian,Pengurugankembalidanperbaikankembali, pengisianpasir,deekstendantandarutekabeltanah dantempatsambungkedalaman0.4meter meter 173BC-TR-0.6 Galian,Pengurugankembalidanperbaikankembali, pengisianpasir,deekstendantandarutekabeltanah dantempatsambungkedalaman0.6meter meter 174BC-TR-5 Galian,Pengurugankembalidanperbaikankembali, pengisianpasir,deekstendantandarutekabeltanah dantempatsambungkedalaman1,5meter meter 175BD-SK PembobokandanperbaikanDindinguntuklubang SparingKabel Titik 176BP-IC PembobokandanperbaikanPlafonuntukrouteIndoor Cable Titik 177SMD-ABS-2A PengadaandanpemasanganAlatSambungMicro Ductcabang/lurus2cabang,termasukconnector,gas block&endcap pcs 178SMD-ABS-3Aidem3cabangpcs 179SMD-ABS-4Aidem4cabangpcs 180DD-MDDI-1A PengadaandanPemasangan5/3.5mmMicroDuct, DirectInstall,1way,untukAirBlownkabelFO termasukconnector meter 181DD-MDDI-2AIdem2waymeter 182DD-MDDI-4AIdem4waymeter 183DD-MDDI-7AIdem7waymeter 184DD-MDDI-12AIdem12waymeter 185DD-MDDI-19AIdem19waymeter 186DD-MDDI-24AIdem24waymeter 187DD-MDDI-1B PengadaandanPemasangan10/8mmMicroDuct, DirectInstall,1way,untukAirBlownkabelFO termasukconnector meter 188DD-MDDI-2BIdem2waymeter 189DD-MDDI-4BIdem4waymeter 190DD-MDDI-7BIdem7waymeter 191DD-MDDI-1C PengadaandanPemasangan12/10mmMicroDuct, DirectInstall,1way,untukAirBlownkabelFO termasukconnector meter 192DD-MDDI-2CIdem2waymeter 193DD-MDDI-4CIdem4waymeter 194DD-MDDI-7CIdem7waymeter 195DD-MDDB-1A PengadaandanPemasangan5/3.5mmMicroDuct, DirectBuried,1way,untukAirBlownkabelFO termasukconnector meter 196DD-MDDB-2AIdem2waymeter 197DD-MDDB-4AIdem4waymeter 198DD-MDDB-7AIdem7waymeter 199DD-MDDB-12AIdem12waymeter 200DD-MDDB-19AIdem19waymeter 201DD-MDDB-24AIdem24waymeter 202DD-MDDB-1B PengadaandanPemasangan10/8mmMicroDuct, DirectBuried,1way,untukAirBlownkabelFO termasukconnector meter 203DD-MDDB-2BIdem2waymeter 204DD-MDDB-4BIdem4waymeter 205DD-MDDB-7BIdem7waymeter 206DD-MDDB-1C PengadaandanPemasangan12/10mmMicroDuct, DirectBuried,1way,untukAirBlownkabelFO termasukconnector meter 207DD-MDDB-2CIdem2waymeter 208DD-MDDB-4CIdem4waymeter 209DD-MDDB-7CIdem7waymeter 210GB-K-A1GambarKertaskalkirukuranA1HardCopy&Softlbr 211GB-L-A1GambarKertaslighdrukukuranA1lbr 212MH-HIS5PembuatanManholeLurusTypeHIS5pcs 213MH-HIS5TPembuatanManholeTypeHIS5Tpcs 214MH-HIIS7PembuatanManholeTypeHIIS7pcs 215MH-HH1PembuatanHandholeTypeHH1pcs 216MH-HH2PembuatanHandholeTypeHH2pcs 217MH-CAPeninggianTutupManhole/Handholepcs 218MH-MODModifikasiManhole/Handhole(sesuailuasan)m3 219MH-RSInstalasistrukturrakdalammanholeyangada.kg 220HH-PIT-60 PembuatanHHukurandiameterdalam(PXLXT= 60x40x60)corbeton1:2:3 pcs 221HH-PIT-40 PembuatanHHukurandiameterdalam(PXLXT= 40x40x40)corbeton1:2:3 pcs KETERANGANNODESIGNATORURAIANPEKERJAANSATUAN
  • 72. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 72 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 6.10 LIST OF ASSEMBLY UNIT DESIGNATOR (6/6) 222HH-PIT-Portable PengadaandanpemasanganHHPitPortable besertaaksesorisnya pcs BNEWITEM newDD-HDPE-Big PengadaandanPemasangan1pipaHDPE/HDPE BIGuntukkabelFO,IncludeSoketHDPE meterUNTUK288 newDD-V4-4 PengadandanPemasanganPipaDuctdengan pengecorandiameterdalam100mm,ketebalan4 mm,4pipa meterOK newHH-80 PembuatanHHukurandiameterdalam(PXLXT= 80x80x80)corbeton1:2:3 pcs new CableTray/Ladder(Plastic)40x40mmBerikut Assesories meter new CableTray/Ladder(Plastic)16x16mmBerikut Assesories meter newBC-PP PengaddaandanPemasanganRisePipeBesiuntuk pengamankabeloptik/titiknaikKUdanGrounding diamater1,5inchpanjang3meter pcsOK newODC-HRB-180pcsOK newODC-HRB-240pcsOK newODC-HRB-420pcsOK newODP-HRB-16pcsOK newODP-HRB-32pcsOK newODP-SSW-8 PengadaandanpemasanganODPtypeClosure Aerial(SSW)Kap8coreberikutspacepasivespliter (1:8),adapterSC/UPC,berikutpelabelan pcs newODP-PW-8 PengadaandanpemasanganODPtypeOudoor/wall Kap8coreberikutspacepasivespliter(1:8),adapter SC/UPC,berikutpelabelan pcsOK newODP-PW-16 PengadaandanpemasanganODPtypeOudoor/wall Kap16coreberikutspace2pasivespliter(1:8), adapterSC/UPC,berikutpelabelan pcsOK newODP-PW-BR-16pcs newODP-PL-BR-16pcs newPengukuranCableExistingCore KETERANGANNODESIGNATORURAIANPEKERJAANSATUAN
  • 73. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 73 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
  • 74. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 74 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
  • 75. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 75 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N Civil Work FOC Laying Work FOC Joint Work FOC Termination Work OTDR Measurement Total Loss Measurement by LS/OPM Construction Work UT (PAT) UT Pass Fail Work Flow to Test-Com(Internal Commissioning Test) and UT (PAT) 1. High Loss Event Detection by OTDR 1.55um for; 1) Feeder Segment, 2) Distribution Segment 2. Fiber Length Measurement Test-Com (Internal Test) (for optical test on Fiber) Preparation of OPM Test Form
  • 76. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 76 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 1 2 3 4 5 6 7 8 9 1011 12 1 2 3 4 5 6 7 8 9 1011 12 1:8 splitter 1 2 3 4 5 6 7 8 1:8 splitter 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 1:4splitter OTB ODC ODP No.1 ODP No.2 Feeder Cable Distribution Cable 1:8 splitter Port#.1 1:4 splitter Port#.1 Splitter #.1 Port#.1 Splitter#.1 Splitter#.2 Port#.1 Port#.1 Feeder Cable Distribution Cable Typical System Cofiguration between OTB and ODP
  • 77. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 77 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N Definition of Segment OTB fo Feeder 1:4 splitter ODC fo Distribution 1:8 splitter ODP fo Drop Rosette ONT BIF patchcord OLT Feeder Segment Distribution Segment (Drop Segment) Splice SC/UPC connector Overall Segment (OTB - ODP) Bi-directional OTDR Measurement shall be done upon request by TELKOM
  • 78. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 78 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N Policy of Test for Optial Measurement • OTDR ; detect partially harmful waveform =only 1.55um (sensitive for fiber bend) • LS/OPM ; for guarantee the final performance of the line 1) Feeder Segment 1-1) Measurment by OTDR with one-way to detect partially harmful event (Bi-directional Measurement shall be done for Segment A - Segment A' upon request by TELKOM.) 1-2) Measurment by LS/OPM 2) Distribution Segment 2-1) Measurment by OTDR from ODC to ODP splitter input (one-way) (because Handy OTDR cannot measure over 1:8 splitter) 2-2) Measurment by LS/OPM 3) Drop Segment Measurment by LS/OPM (Drop Segment cannot be measured by OTDR because drop cable length is <100m) 4) End to End ; Overall Section Measurment only by LS/OPM (because Handy OTDR cannot measure over 1:8 splitter)
  • 79. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 79 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N Optical Light Source NEW Patch-cord Optical Power Meter NEW Battery KALIBRASI (Input Power Measurement) Method of Measurement Leave the Light Source 5 ~ 10 min. to make the input power (Pi) stable after switch on. • Check Pi three (3) times at least • Max.Pi - Min.Pi < 0.1dB • Average Pi Ex. Good Bad 1st - 8.20dBm -8.20dBm 2nd -8.18dBm -8.18dBm 3rd -8.22dBm -8. 07dBm Ave -8. 20dBm Pi = 8.20dB DO NOT TAKE OUT Optical Light Source Optical Power Meter TAKE OUT (OPM SIDE) Prior to LS/OPM Measurement, the INPUT POWER (Pi) shall be measured and recorded.
  • 80. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 80 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N OTB fo Feeder 1:4 splitter ODC Segment A' Segment A' cannot be measured by OTDR because 4-OTDR signal overlap in this segment. Optical performance of this segment is guaranteed by Test Report of splitter module and measurment of Segment A by LS/OPM OTB fo Feeder 1:4 splitter ODC Segment A Segment A' OTDR Optical Power Meter OTDR@1550nm LS/OPM @1310nm & 1550nm Patchcord is not needed for measurment Optial Light Source Segment A 1.1 Feeder Segment
  • 81. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 81 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 1.2 Distribution Segment-1 (SCPT and SSW; ODP installed) fo Distribution 1:8 splitter ODP Segment B ODC Segment B' OTDR@1550nm LS/OPM @1310nm & 1550nm Segment B' cannot measure by OTDR because 8-OTDR signal overlap in this segment. Optical performance of this segment is guaranteed by Test Report of splitter module and measurment of Segment B by LS/OPM. fo Distribution 1:8 splitter ODP Segment B ODC Bi-directional mesurement by ODR is not possible because Handy OTDR cannot measure over 1:8 splitter. OTDR Optial Light Source Optical Power Meter
  • 82. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 82 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 1.3 Distribution Segment-2 SCPT/SSW CADANGAN or, SSW; ODP not installed, only cable installed fo Distribution Segment B ODC OTDR@1550nm LS/OPM @1310nm&1550nmfo Distribution Segment B ODC temporarily splice pigtail to end of fiber OTDR Optial Light Source Optical Power Meter
  • 83. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 83 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 1.4 Drop Segment ODP fo Drop Rosette Segment C LS/OPM @1310nm&1550nm Drop segment cannot be measured by OTDR because drop cable length is <100m. Optial Light Source Optical Power Meter
  • 84. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 84 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 1.5 End to End Overall (SCPT and SSW; ODP installed) OTB fo Feeder 1:4 splitter ODC fo Distribution 1:8 splitter ODP fo Drop Rosette Segment A Segment B Segment CSegment D LS/OPM @1310nm & 1550nm Note: Overall segment cannot be measured by OTDR because splitter is included in the line. Optial Light Source Optical Power Meter
  • 85. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 85 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 1.6 Calculation of Attenuation Limit (LS/OPM Test) Segment Calculation of Attenuation Limit Remarks 1. Feeder Cable Segment - 1310nm A-F13= {0.35dB/km x .. Km} + {0.1dB x (No. of Splice)} + {0.25dB x (No. of Connector)} A-F13: Attenuation Limit of Feeder Cable at 1310nm - 1550nm A-F15= {0.215dB/km x .. Km} + {0.1dB x (No. of Splice)} + {0.25dB x (No. of Connector)} A-F15: Attenuation Limit of Feeder Cable at 1550nm 2. Distribution Cable Segment - 1310nm A-D13= {0.35dB/km x .. Km} + {0.1dB x (No. of Splice)} + {0.25dB x (No. of Connector)} A-D13: Attenuation Limit of Distribution Cable at 1310nm - 1550nm A-D15= {0.215dB/km x .. Km} + {0.1dB x (No. of Splice)} + {0.25dB x (No. of Connector)} A-D15: Attenuation Limit of Distribution Cable at 1550nm 3. Drop Cable Segment - 1310nm A-DR13= {0.35dB/km x .. Km} + {0.25dB x (No. of Connector)} A-DR13: Attenuation Limit of Distribution Cable at 1310nm - 1550nm A-DR15= {0.215dB/km x .. Km} + {0.25dB x (No. of Connector)} A-DR15: Attenuation Limit of Distribution Cable at 1550nm 4. End to End/Overall Section - 1310nm A-EE13= [A-F13] + 7.5dB (Splitter 1x4) + [D-F13] + 11.0dB (Splitter 1x8) + [A-DR13] A-EE13: Overall Attenuation of End to End at 1310nm - 1550nm A-EE15= [A-F15] + 7.5dB (Splitter 1x4) + [D-F15] + 11.0dB (Splitter 1x8) + [A-DR15] A-EE15: Overall Attenuation of End to End at 1550nm
  • 86. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 86 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N
  • 87. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 87 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N Form # Name From / To Ia / Ib Total Loss Measurement 1310nm / 1550nm Subsystem: Oerall Segment (OTB-ODC-ODP) From: OTB ①①①① To: ODP ⑤⑤⑤⑤ IIa / IIb Seg.A(OTB-ODC_splitter) Loss Measurement 1310nm/ 1550nm Subsystem: Feeder Segment (OTB-ODC) without splitter From: OTB ①①①① To: ODC ②②②② IIc / IId Seg.A(OTB-ODC_splitter) Loss Measurement 1310nm/ 1550nm Subsystem: Feeder Segment (OTB-ODC) with passive splitter 1:4 From: OTB ①①①① To:ODC ④④④④ IIIa / IIIb Seg.B(ODC-ODP) Loss Measurement 1310nm/1550nm Subsystem: Segment B (ODC - ODP) From: ODC ④④④④ To: ODP ⑤⑤⑤⑤ 2.1 APPLICATION OF MEASUREMENT FORMS Form Ia / Ib (Overall Segment) OTB Feeder Cable ODC Distribution Cable 1:8 splitter ODP No.X Port#.1 1:4 splitter Port#.1 Splitter #.1 Port#.1 Splitter #.1 Port#.1 Form IIa / IIb (Feeder Segment / Seg.A) Form IIIa / IIIb (Distribution Segment / Seg.B) Form IIc / IId (Feeder Segment / Seg.A) 1 2 3 4 6 5
  • 88. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 88 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 2.1.1 FORM I a/I b: Overall Segment (OTB-ODC-ODP) 2 6 Distribution Cable Core No. to be terminated at ODP NOTE: 1) Input in accordance with the site information, condition 2) Input when measurement 3 5 1 OTB Feeder Cable ODC Distribution Cable 1:8 splitter ODP No.X Port#.1 1:4 splitter Port#.1 Splitter#.1 Port#.1 Splitter#.1 Port#.1 OVERALL SEGMENT 1 2 3 4 6 5
  • 89. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 89 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 2.1.2 FORM II a/II b: Feeder Segment (OTB-ODC) without splitter OTB Feeder Cable ODC Distribution Cable 1:8 splitter ODP No.X Port#.1 1:4 splitter Port#.1 Splitter#.1 Port#.1 Splitter#.1 Port#.1 FEEDER SEGMENT 1 2 3 4 6 5 NOTE: 1) Input in accordance with the site information, condition 2) Input when measurementInput Tray No. 1 2
  • 90. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 90 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 2.1.3 FORM II c/II d: Feeder Segment (OTB-ODC) with 1:4 Passive Splitter OTB Feeder Cable ODC Distribution Cable 1:8 splitter ODP No.X Port#.1 1:4 splitter Port#.1 Splitter#.1 Port#.1 Splitter#.1 Port#.1 FEEDER SEGMENT with Splitter 1 2 3 4 6 5 1 3 4 NOTE: 1) Input in accordance with the site information, condition 2) Input when measurement
  • 91. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 91 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 2.1.4 FORM III a/III b: Distribution Segment (ODC-ODP) OTB Feeder Cable ODC Distribution Cable 1:8 splitter ODP No.X Port#.1 1:4 splitter Port#.1 Splitter#.1 Port#.1 Splitter#.1 Port#.1 DISTRIBUTION SEGMENT 1 2 3 4 6 5 6 3 4 5 NOTE: 1) Input in accordance with the site information, condition 2) Input when measurement
  • 92. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 92 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 2.2 MEASUREMENT FORMS (File: UT-Form Measurement -r2.2.xls) Note: 1) Forms provided hereunder is "r-2.3a", which is the latest version as of 28 June, 2013. 2) It is to request users to confirm the latest version to JF DJAFa Consortium before use Forms. 3) Use Forms of Excel format for submission purpose. 4) In case if the form is not enough (e.g. more than 5 ODP (1:8 Splitter) are exist in one distribution cable), the related "Worksheet of Excel" (e.g. Form I and III) shall be duplicated/copied. 5) Do not incert any Line/Raw in the form so as not to alter the calculation formula in the sheet.
  • 93. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 93 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 2.2.1 FORM I a: Overall Segment (OTB-ODC-ODP) @ 1310nm FORM:Ia PTTELEKOMUNIKASIINDONESIA SubSistem:OVERALLSEGMENT(OTB-ODC-ODP) ODCNo.CAPACITYE00˚˚˚˚00'00" CABLENo.WAVELENGTH RESULT No.PortNo.Pin(dB)Pout(dB)Pout-Pin(dB)PASS/FAILSE CoreNo.1-PASS 2-PASS ODPNo.3-PASS 4-PASS 5-PASS SplitterNo.6-PASS 7-PASS 8-PASS CoreNo.1-PASS 2-PASS ODPNo.3-PASS 4-PASS 5-PASS SplitterNo.6-PASS 7-PASS 8-PASS CoreNo.1-PASS 2-PASS ODPNo.3-PASS 4-PASS 5-PASS SplitterNo.6-PASS 7-PASS 8-PASS CoreNo.1-PASS 2-PASS ODPNo.3-PASS 4-PASS 5-PASS SplitterNo.6-PASS 7-PASS 8-PASS Catatan:PowerMeterdigunakanuntuktestpelurusankabel *)TotalLoss=(Cablelengthx0,35dB+Connectorx0.25dB+Splitter1:4x7.25dB+Splitter1:8x10.38dB+Splicex0.1dB) CALCULATIONOFLOSSBUDGET: Unit Attenuation Splitter-.1Splitter-.2Splitter-.3Splitter-.4 1.CABLELENGTH(km)0.35---- 2.No.ofSPLICE(pcs)0.1 3.No.ofCONNECTOR(pcs)0.25 4.SPLITTER1:4(1pc)7.25 5.SPLITTER1:8(1pc)10.38 0.000.000.000.00 FEEDER DISTRIBUTIO N DISTRIBUTIO N DISTRIBUTIO N DISTRIBUTIO N CABLELENGTH(km): Note:CABLELENGTHofOTDRIndication OverallLossMeasurement1310nm DATEOFMEASUREMENT: DAERASTONAMA LOKASI ATTENUATIONLIMITATION(dB) - - ODC PORTNo. LOSS BUDGET - - 00˚˚˚˚00'00" 00˚˚˚˚00'00" 00˚˚˚˚00'00" 00˚˚˚˚00'00" 00˚˚˚˚00'00" 00˚˚˚˚00'00" ODPCOORDINATES 00˚˚˚˚00'00" Measurementtools:PowerMeter Specification/limitation:dB(Cablelengthx0.35dB+Connectorx0.25dB+Splitter1:4x7.25dB+Splitter1:8x10.38dB+Splicex0.1dB) NoofCores1310nm REMARKS FEEDERCABLEDISTRIBUTIONCABLE 00˚˚˚˚00'00" ODPATTENUATION(dB) NoofCores OTBPortNo. COORDINATESS00˚˚˚˚00'00" CABLENo.
  • 94. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 94 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 2.2.2 FORM I b: Overall Segment (OTB-ODC-ODP) @ 1550nm FORM:Ib PTTELEKOMUNIKASIINDONESIA SubSistem:OVERALLSEGMENT(OTB-ODC-ODP) ODCNo.CAPACITYE00˚˚˚˚00'00" CABLENo.WAVELENGTH ODPPortNo.ODPSpecificationlimitationAttenuation(dB)ResultRemarks RESULT No.PortNo.Pin(dB)Pout(dB)Pout-Pin(dB)PASS/FAILSE CoreNo.1-PASS 2-PASS ODPNo.3-PASS 4-PASS 5-PASS SplitterNo.6-PASS 7-PASS 8-PASS CoreNo.1-PASS 2-PASS ODPNo.3-PASS 4-PASS 5-PASS SplitterNo.6-PASS 7-PASS 8-PASS CoreNo.1-PASS 2-PASS ODPNo.3-PASS 4-PASS 5-PASS SplitterNo.6-PASS 7-PASS 8-PASS CoreNo.1-PASS 2-PASS ODPNo.3-PASS 4-PASS 5-PASS SplitterNo.6-PASS 7-PASS 8-PASS *)TotalLoss=(Cablelengthx0,215dB+Connectorx0.25dB+Splitter1:4x7.25dB+Splitter1:8x10.38dB+Splicex0.1dB) CALCULATI ONOF ATTENUATI ONLIMIT: Unit Attenuation Splitter-.1Splitter-.2Splitter-.3Splitter-.4 0.2150000 2.No.ofSPLICE(pcs)0.1 3.No.ofCONNECTOR(pcs)0.25 4.SPLITTER1:4(1pc)7.25 5.SPLITTER1:8(1pc)10.38 0.000.000.000.00 FEEDER DISTRIBUTIO N DISTRIBUTIO N DISTRIBUTIO N DISTRIBUTIO N CABLELENGTH(km): Note:CABLELENGTHofOTDRIndication TotalLossMeasurement1550nm DATEOFMEASUREMENT: DAERASTO ATTENUATION(dB)ODPCOORDINATES FEEDERCABLE COORDINATESS00˚˚˚˚00'00" CABLENo. 1.CABLELENGTH(km) ATTENUATIONLIMITATION(dB) ODC PORTNo. LOSS BUDGET NAMA LOKASI NoofCores 00˚˚˚˚00'00" 00˚˚˚˚00'00" 00˚˚˚˚00'00" 00˚˚˚˚00'00" DISTRIBUTIONCABLENoofCores OTBPortNo. Specification/limitation:dB(Cablelengthx0.215dB+Connectorx0.25dB+Splitter1:4x7.25dB+Splitter1:8x10.38dB+Splicex0.1dB) ODP 00˚˚˚˚00'00" 00˚˚˚˚00'00" 00˚˚˚˚00'00" 00˚˚˚˚00'00" 1550nm REMARKS
  • 95. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 95 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 2.2.3 FORM II a: Feeder Segment (OTB-ODC) without splitter @ 1310nm FORM:IIa PTTELEKOMUNIKASIINDONESIA WAVELENGTH CAPACITY OTBRESULT PORTNo.TrayNo.PortNo.Pin(dB)Pout(dB)Pout-Pin(dB)PASS/FAIL 11-PASS 22-PASS 33-PASS 44-PASS 55-PASS 66-PASS 77-PASS 88-PASS 99-PASS 1010-PASS 1111-PASS 1212-PASS 131-PASS 142-PASS 153-PASS 164-PASS 175-PASS 186-PASS 197-PASS 208-PASS 219-PASS 2210-PASS 2311-PASS 2412-PASS 251-PASS 262-PASS 273-PASS 284-PASS 295-PASS 306-PASS 317-PASS 328-PASS 339-PASS 3410-PASS 3511-PASS 3612-PASS 371-PASS 382-PASS 393-PASS 404-PASS 415-PASS 426-PASS 437-PASS 448-PASS 459-PASS 4610-PASS 4711-PASS 4812-PASS Catatan:PowerMeterdigunakanuntuktestpelurusankabel *)TotalLoss=(Cablelengthx0,35dB+Connectorx0.25dB+Splicex0.1dB) CALCULATIONOFATTENUATIONLIMIT: UnitAttenuationODC 1.CABLELENGTH(km)0.35- 2.No.ofSPLICE(pcs)0.1 3.No.ofCONNECTOR(pcs)0.25 0.00 FEEDER CABLELENGTH(km) Note:CABLELENGTHofOTDRIndication NAMA LOKASI Seg.A(OTB-ODC_splitter)LossMeasurement1310nm SubSistem:FEEDERSEGMENT(OTB-ODC)WITHOUTSPLITTERDATEOFMEASUREMENT: DAERASTO Measurementtools:PowerMeter ODC NAME/TYPE 1310nmNo.ofCores ODCCOORDINATESS00˚˚˚˚00'00"E00˚˚˚˚00'00" Specification/limitation:dB(Cablelengthx0.35dB+Connectorx0.25dB+Splitter1:4x7.25dB+Splicex0.1dB) ODCATTNUATION(dB) ATTENUATIONLIMITATION(dB) REMARKS FEEDERCABLE CABLENo. No.LOSS BUDGET -
  • 96. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 96 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 2.2.4 FORM II b: Feeder Segment (OTB-ODC) without splitter @ 1550nm FORM:IIb PTTELEKOMUNIKASIINDONESIA WAVELENGTH CAPACITY OTBRESULT PORTNo.TrayNo.PortNo.Pin(dB)Pout(dB)Pout-Pin(dB)PASS/FAIL 11-PASS 22-PASS 33-PASS 44-PASS 55-PASS 66-PASS 77-PASS 88-PASS 99-PASS 1010-PASS 1111-PASS 1212-PASS 131-PASS 142-PASS 153-PASS 164-PASS 175-PASS 186-PASS 197-PASS 208-PASS 219-PASS 2210-PASS 2311-PASS 2412-PASS 251-PASS 262-PASS 273-PASS 284-PASS 295-PASS 306-PASS 317-PASS 328-PASS 339-PASS 3410-PASS 3511-PASS 3612-PASS 371-PASS 382-PASS 393-PASS 404-PASS 415-PASS 426-PASS 437-PASS 448-PASS 459-PASS 4610-PASS 4711-PASS 4812-PASS Catatan:PowerMeterdigunakanuntuktestpelurusankabel *)TotalLoss=(Cablelengthx0,215dB+Connectorx0.25dB+Splicex0.1dB) CALCULATIONOFATTENUATIONLIMIT: UnitAttenuationODC 1.CABLELENGTH(km)0.215- 2.No.ofSPLICE(pcs)0.1 3.No.ofCONNECTOR(pcs)0.25 0.00 FEEDER CABLELENGTH(km) Note:CABLELENGTHofOTDRIndication NAMA LOKASI Seg.A(OTB-ODC_splitter)LossMeasurement1550nm SubSistem:FEEDERSEGMENT(OTB-ODC)WITHOUTSPLITTERDATEOFMEASUREMENT: DAERASTO Measurementtools:PowerMeter ODC NAME/TYPE 1550nmNo.ofCores ODCCOORDINATESS00˚˚˚˚00'00"E00˚˚˚˚00'00" Specification/limitation:dB(Cablelengthx0.215dB+Connectorx0.25dB+Splitter1:4x7.25dB+Splicex0.1dB) ODCATTNUATION(dB) ATTENUATIONLIMITATION(dB) REMARKS FEEDER CABLE CABLENo. No.LOSS BUDGET -
  • 97. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 97 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 2.2.5 FORM II c: Feeder Segment (OTB-ODC) with 1:4 Passive Splitter @ 1310nm FORM:IIc PTTELEKOMUNIKASIINDONESIA WAVELENGTH CAPACITY OTBRESULT PORTNo.SplitterPortNo.Pin(dB)Pout(dB)Pout-Pin(dB)PASS/FAIL 11-PASS 22-PASS 33-PASS 44-PASS 51-PASS 62-PASS 73-PASS 84-PASS 91-PASS 102-PASS 113-PASS 124-PASS 131-PASS 142-PASS 153-PASS 164-PASS 171-PASS 182-PASS 193-PASS 204-PASS 211-PASS 222-PASS 233-PASS 244-PASS 251-PASS 262-PASS 273-PASS 284-PASS 291-PASS 302-PASS 313-PASS 324-PASS 331-PASS 342-PASS 353-PASS 364-PASS 371-PASS 382-PASS 393-PASS 404-PASS 411-PASS 422-PASS 433-PASS 444-PASS 451-PASS 462-PASS 473-PASS 484-PASS Catatan:PowerMeterdigunakanuntuktestpelurusankabel *)TotalLoss=(Cablelengthx0,35dB+Connectorx0.25dB+Splitter1:4x7.25dB+Splicex0.1dB) CALCULATIONOFATTENUATIONLIMIT: UnitAttenuationODC 1.CABLELENGTH(km)0.35- 2.No.ofSPLICE(pcs)0.1 3.No.ofCONNECTOR(pcs)0.25 4.SPLITTER1:4(1pc)7.25 0.00 FEEDER CABLELENGTH(km) Note:CABLELENGTHofOTDRIndication Seg.A(OTB-ODC_splitter)LossMeasurement1310nm SubSistem:FEEDERSEGMENT(OTB-ODC)WITHPASSIVESPLITTER1:4DATEOFMEASUREMENT: DAERASTO No. ODCATTNUATION(dB) ATTENUATIONLIMITATION(dB) 1 2 3 4 5 6 7 9 10 11 12 LOSS BUDGET - 1310nm REMARKS 8 Specification/limitation:dB(Cablelengthx0.35dB+Connectorx0.25dB+Splitter1:4x7.25dB+Splicex0.1dB) No.ofCores ODCCOORDINATESS00˚˚˚˚00'00"E00˚˚˚˚00'00" Measurementtools:PowerMeter FEEDERCABLE CABLENo. ODC NAMA LOKASI NAME/TYPE
  • 98. HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 98 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N 2.2.6 FORM II d: Feeder Segment (OTB-ODC) with 1:4 Passive Splitter @ 1550nm FORM:IId PTTELEKOMUNIKASIINDONESIA WAVELENGTH CAPACITY OTBRESULT PORTNo.SplitterPortNo.Pin(dB)Pout(dB)Pout-Pin(dB)PASS/FAIL 11-PASS 22-PASS 33-PASS 44-PASS 51-PASS 62-PASS 73-PASS 84-PASS 91-PASS 102-PASS 113-PASS 124-PASS 131-PASS 142-PASS 153-PASS 164-PASS 171-PASS 182-PASS 193-PASS 204-PASS 211-PASS 222-PASS 233-PASS 244-PASS 251-PASS 262-PASS 273-PASS 284-PASS 291-PASS 302-PASS 313-PASS 324-PASS 331-PASS 342-PASS 353-PASS 364-PASS 371-PASS 382-PASS 393-PASS 404-PASS 411-PASS 422-PASS 433-PASS 444-PASS 451-PASS 462-PASS 473-PASS 484-PASS Catatan:PowerMeterdigunakanuntuktestpelurusankabel *)TotalLoss=(Cablelengthx0,215dB+Connectorx0.25dB+Splitter1:4x7.25dB+Splicex0.1dB) CALCULATIONOFATTENUATIONLIMIT: UnitAttenuationODC 1.CABLELENGTH(km)0.215- 2.No.ofSPLICE(pcs)0.1 3.No.ofCONNECTOR(pcs)0.25 4.SPLITTER1:4(1pc)7.25 0.00 FEEDER CABLELENGTH(km) Note:CABLELENGTHofOTDRIndication Seg.A(OTB-ODC_splitter)LossMeasurement1550nm SubSistem:FEEDERSEGMENT(OTB-ODC)WITHPASSIVESPLITTERDATEOFMEASUREMENT: DAERASTO No. ODCATTNUATION(dB) ATTENUATIONLIMITATION(dB) 6 1 2 3 4 5 12 7 8 9 10 11 - ODC NAMA LOKASI NAME/TYPE Specification/limitation:dB(Cablelengthx0.215dB+Connectorx0.25dB+Splitter1:4x7.25dB+Splicex0.1dB) No.ofCores ODCCOORDINATESS00˚˚˚˚00'00"E00˚˚˚˚00'00" Measurementtools:PowerMeter 1550nm REMARKS FEEDER CABLE CABLENo. LOSS BUDGET