The Guide Right Surgical Guide System is a system of components for the fabrication and correction of diagnostic and surgical dental implant guides in 1 or 2 dimensions.
1. Mandibular Posterior Case
Correcting Divergent Angled Diagnostic Guide Sleeves
Featuring:
Magnetic Offset Guide Posts
Open Guide Sleeves
Diagnostic Guide Sleeves [to increase diameter of guide sleeve]
GALAXIS Cone Beam Software Evaluation
Generation ll ▪ Guide Post Bending Tool
CALHO 2.2013
2. Magnetic Guide Posts
Straight
3.0 mm od
Offset
3.0 od X 0.5 mm os
3.0 od X 1.0 mm os
3.0 od X 1.5 mm os
3.0 od X 2.0 mm os
3.0 od X 2.5 mm os
3.0 od X 3.0 mm os
3. Magnetic Guide Post & Open Guide Sleeve Set
3.0 mm Open Guide Sleeve
3.3 mm Open Guide Sleeve
3.7 mm Open Guide Sleeve
4.0 mm Open Guide Sleeve
3.0 mm Straight Magnetic Guide Posts
3.0 mm Offset Magnetic Guide Post
2.0 mm Pilot Drills (to start the osteotomy)
Other Drill Sizes Available on Request
5. Holes are drilled deliberately accentuating inaccurately initially
planned long axis of the implant positions with a 3/32” drill.
6. Straight 3 mm guide posts are placed in the questionable
holes drilled in the positions of #19 and #20.
7. View of 3 mm straight guide posts in place showing the divergent angles.
8. 3 mm guide sleeves are positioned on the guide post with the cleat facing the
lingual. The cast is lubricated & Triad® Gel added to the guide sleeves
capturing the cleats including lingual & incisal surfaces of several of the
adjacent teeth. After curing the DIAGNOSTIC guide & securely seating
it in the patient, a cone beam X-ray is taken.
10. Preview of Pre-op Corrections
ANGULAR CORRECTIONS
#19
9° Bend toward the buccal
#20
7° Bend rotated toward the lingual
Cosine is applied to determine correction data.
* see next 3 slide
11. DéPlaque
Pythagorean Theorem
COSINE Calculations for Guide Right™ Guides
The cosine of 45°
is recommended for Guide Right corrections
BECAUSE
rotating the offset guide post half way
between 2 adjacent planes (90° apart) is 45°.
12. Correction based on the calculations
from the Pythagorean Theorem
To move the position of the guide sleeve 1.4 mm both mesially & buccally:
► use a 3 mm X 1.5 mm offset guide post
► and direct the offset 45º facially and buccally.
Cosine: 1.5 mm X 0.71 = 1.06 mm
see slideshow > Use of Pythagorean Theorem in 9 Single Implant Case
13. A= cosine of 45º X 1.5
(0.707 X 1.5 mm = 1.06 mm
14. GALAXIS
Panoramic view #19 highlighted
The mandibular nerve is drawn in with the GALAXIS software.
16. 9°
L B
GALAXIS tangential cross sectional
# 19 evaluated in GALAXIS software and 9° corrected angle drawn in.
17. L B
9°
#19 tangential #19 cross sectional
GALAXIS
A cone beam X-ray is taken with the DIAGNOSIC guide in place.
The images are evaluated with the software.
The cross sectional image on the right will be corrected 9°
rotated toward the buccal surface.
19. 9°
L B
GALAXIS #20 tangential #20 cross sectional
The image of the mesial implant will be rotated 7° toward the lingual
20. 7°
L B
GALAXIS #20 tangential
#20 tangential #20 cross sectional
#20 cross sectional
The image of the mesial implant will be rotated 7 ° toward the lingual
26. Buccal view
3 mm guide posts with (3 x 2 mm id) diagnostic guide sleeves (1 cleat)
serving to increase the diameter of the 3 mm guide sleeve
for use with 4 mm open guide sleeve
27. occlusal view
3 mm guide post with 2 mm id diagnostic guide sleeve (1 cleat)
serving to increase the diameter of the 3 mm guide sleeve
for use with 4mm open guide sleeve
28. 3 mm diagnostic guide sleeves - 3 mm magnetic guide posts
with 4 mm open guide sleeves added
32. Guide Right™
GENERATION II ▪ GUIDE POST BENDING TOOL
SINGLE BEND review
Step 1 Place bending tool plate on a secure flat surface with the degree increments
at the top & the stainless steel bar with the v-cut at the bottom.
Step 2 Locate 3/32” hole in the center of the v-cut and place the bottom half of the
guide post into the hole. Tighten the set screw.
Step 3 Locate the hole in the bottom of the stylus that you will use that will fit over
the top half of the guide post (3.0 mm, 4.0 mm or 5.0 mm).
Step 4 Fit the stylus over the guide post securely with the point directed at
zero degrees and the bottom of the stylus in contact with the V block.
Step 5 Using the stylus as a lever, bend the guide post to the degree of angle of
correction. You may need to ease the point of the stylus beyond the
point of the desired degree.
Step 6 Loosen screw and remove guide post and the stylus to find the guide post
bent to the desired angle.
33. Guide Right™
GENERATION II ▪ Guide Post BENDING TOOL
COMPOUND BEND overview
Step 1 Position a straight or offset guide post in the bending plate, tightening the set
screw against one of the flat surfaces on the lower half of the guide post.
Step 2 The 1st bend can be made to the right or left direction.
Step 3 The set screw is loosened and the guide post is rotated 90 ° next flat surface.
Step 4 The 2nd bend in the second plane is made after rotating the guide post up away
from the surface of the bending plate to register the stylus point back at 0 degrees.
Step 5 Slide the stylus support bar down under the stylus until it supports the stylus.
Tighten the side screws before making the second bend.
Step 6 The second bend can be made in either direction according to the x-ray.
Step 7 Remove the stylus and place the guide post back in the cast with the
appropriate side indicated by a mark facing the buccal or lingual surface.
Be sure the post is in the correct position.
If the post needs to be corrected by a linear movement an offset guide post can be used.
Off sets available in the 3 mm guide post: 0.5,1,1.5, 2.0 ,or 3.0 mm.
34. Guide Right™
Products used in this presentation
1 - 3/32” drill
2 - 3 mm Guide Post
2 - 3 mm Guide Sleeve
2 - 3 mm x 2 mm id Diagnostic Guide Sleeve [1 cleat]
2 - 4.0 mm Open Guide Sleeve (short)
1 - 2.0 mm x 5.0 mm Pilot Drill
1 - 2.0 mm x 10.0 mm Pilot Drill
Triad® Gel
Generation ll ▪ Guide Post Bending Tool
1.800.314.0065 • www.deplaque.com
35. A System of Components
for the fabrication and correction of diagnostic & surgical guides
in one or two dimensions
In-office or lab fabrication
Evaluate with 2D & 3D imaging
Allows linear and angular correction
Enables precision implant placement
Cost effective
36. Guide Right™ Surgical Guide System
fabricate ▪ evaluate ▪ correct ▪ verify ▪ place
Start With Precision. Place With Confidence.™
1.800.314.0065 • www.deplaque.com