SlideShare une entreprise Scribd logo
1  sur  106
Télécharger pour lire hors ligne
PRODUCT CATALOGUEPRODUCT CATALOGUE
www.esitas.comwww.esitas.com
Company ProfileCompany Profile
M.V. Current TransformersM.V. Current Transformers
Technical Information About Current TransformersTechnical Information About Current Transformers
ATB 1O-BATB 1O-B
ATB 1O-BSATB 1O-BS / ATB 2O-BSATB 2O-BS
ATB 1O-1OATB 1O-1O // ATB 1O-15ATB 1O-15
ATB 2O-BATB 2O-B
ATB 2O-3AATB 2O-3A / ATB 2O-3BATB 2O-3B
ATATB 2O-1OB 2O-1O / ATB 2O-15ATB 2O-15
ATB 3O-SATB 3O-S
ATB 3O-4ATB 3O-4 / ATB 3O-5ATB 3O-5 / ATB 3O-1OATB 3O-1O
ATU 24ATU 24
ES24 C3-BES24 C3-B
ATD 1OATD 1O / 2O2O
ATN 17ATN 17 // ESO 17CESO 17C // ATN 24ATN 24
ATH 2OATH 2O / 2121 // 2222
ATH 3OATH 3O / 3232
ATH 3O-NATH 3O-N / 32-N32-N
ATH 52ATH 52
L.V Current TransformersL.V Current Transformers
KAP TypeKAP Type
A-Kap Type (Split Type)A-Kap Type (Split Type)
Indoor & Outdoor Ring TypeIndoor & Outdoor Ring Type
LPCT 115LPCT 115
LPCT 16OLPCT 16O
Voltage TransformersVoltage Transformers
Technical Information About Voltage TransformersTechnical Information About Voltage Transformers
VTB 1O-SVTB 1O-S / VTB 1O-KVTB 1O-K / VTB 2OVTB 2O / VTB 2O-KVTB 2O-K
VTB 3O-KVTB 3O-K
VT 2O-BVT 2O-B // VTB 3OVTB 3O
2 VTB 1O2 VTB 1O / 2 VTB 2O2 VTB 2O
2 VT 2O-B2 VT 2O-B / 2 VTB 32 VTB 3OO / 2 VT 4O-2OO2 VT 4O-2OO
VTB 1O-KFVTB 1O-KF / VTB 2O-KFVTB 2O-KF / VTB 3O-KFVTB 3O-KF
ES 12 VR-FES 12 VR-F / ES 24 V2-FES 24 V2-F
VTB 1O-SFVTB 1O-SF / VTB 1O-EFVTB 1O-EF/ VTB 2O-FVTB 2O-F
VTB 3O-FVTB 3O-F
ES 17 V3ES 17 V3
ES 24 V2-BES 24 V2-B
ES 24 V1ES 24 V1
VTU 24VTU 24
VTH 2OVTH 2O / VTH 3OVTH 3O
VTH 2O-NVTH 2O-N / VTH 3O-NVTH 3O-N
2VTH 2O2VTH 2O / 2VTH 3O2VTH 3O
2VTH 2O-N2VTH 2O-N / 2VTH 3O-N2VTH 3O-N
InsulatorsInsulators
Technical Information About InsulatorsTechnical Information About Insulators
Special ProductsSpecial Products
Page 2Page 2
Page 5Page 5
Page 6Page 6
Page 1OPage 1O
Page 12Page 12
Page 14Page 14
Page 16Page 16
Page 18Page 18
Page 2OPage 2O
Page 22Page 22
Page 24Page 24
Page 26Page 26
Page 28Page 28
Page 3OPage 3O
Page 32Page 32
Page 34Page 34
Page 36Page 36
Page 38Page 38
Page 4OPage 4O
Page 44Page 44
Page 47Page 47
Page 49Page 49
Page 5OPage 5O
Page 51Page 51
Page 53Page 53
Page 54Page 54
Page 58Page 58
Page 6OPage 6O
Page 62Page 62
Page 64Page 64
Page 66Page 66
Page 68Page 68
Page 7OPage 7O
Page 72Page 72
Page 74Page 74
Page 76Page 76
Page 78Page 78
Page 8OPage 8O
Page 82Page 82
Page 84Page 84
Page 86Page 86
Page 88Page 88
Page 9OPage 9O
Page 93Page 93
Page 94Page 94
Page 1OOPage 1OO
CONTENTSCONTENTS
Page 43Page 43
22
GENERAL INFORMATION ABOUT ESITAS GROUP COMPANIESGENERAL INFORMATION ABOUT ESITAS GROUP COMPANIES
Mission StatementMission Statement
‘’ As Esitas Group, we aim to be the main supplier of the market leaders in the world transformer‘’ As Esitas Group, we aim to be the main supplier of the market leaders in the world transformer
industry and to be a permanent player in the developing countries; by keeping our leader positionindustry and to be a permanent player in the developing countries; by keeping our leader position
in domestic market in instrument transformers and increasing awareness of our products in thein domestic market in instrument transformers and increasing awareness of our products in the
global market, together with continuously improving our existent quality and introducing innovati-global market, together with continuously improving our existent quality and introducing innovati-
ons in order to increase efficiency for ourselves and our customers.ons in order to increase efficiency for ourselves and our customers.
Group Companies:Group Companies:
Esitas Brand has been in the transformer industry more than 25 years. Esitas Group CompaniesEsitas Brand has been in the transformer industry more than 25 years. Esitas Group Companies
have been producing and serving the electrical products and contacting businesses with twohave been producing and serving the electrical products and contacting businesses with two
factories specializing in their markets.factories specializing in their markets.
ESITAS ELEKTRIKESITAS ELEKTRIK is the parent company of the group located in Istanbul, Turkey producesis the parent company of the group located in Istanbul, Turkey produces
and sells Low and Medium Voltage Instrument Transformers (both Current - Voltage and Indoor-and sells Low and Medium Voltage Instrument Transformers (both Current - Voltage and Indoor-
Outdoor Types), Low and Medium Voltage Insulators and LPCT’s.Outdoor Types), Low and Medium Voltage Insulators and LPCT’s.
ESITAS ELEKTRIK is in the preferred suppliers list of Turkish Electric Authority, has been selling toESITAS ELEKTRIK is in the preferred suppliers list of Turkish Electric Authority, has been selling to
many foreign electricity authorities and to various branches of multinational market leaders in themany foreign electricity authorities and to various branches of multinational market leaders in the
industry like ABB, Schneider, Siemens and others.industry like ABB, Schneider, Siemens and others.
COMPANY PROFILECOMPANY PROFILE
www.esitas.comwww.esitas.com
3
PT ESITAS PACIFICPT ESITAS PACIFIC is the Group’s production plant located in Jakarta Indonesia produces and sellsis the Group’s production plant located in Jakarta Indonesia produces and sells
Low and Medium Voltage Instrument Transformers (both Current-Voltage and Indoor-Outdoor Types),Low and Medium Voltage Instrument Transformers (both Current-Voltage and Indoor-Outdoor Types),
Low and Medium Voltage Insulators. Indonesia founded to serve the customers more convenientlyLow and Medium Voltage Insulators. Indonesia founded to serve the customers more conveniently
in Asia Pacific zone and to further furnish its existence in the world market.in Asia Pacific zone and to further furnish its existence in the world market.
With its mission of ‘’ ... continuously improving our existent quality and introducing innovationsWith its mission of ‘’ ... continuously improving our existent quality and introducing innovations
in order to increase efficiency for ourselves and our customers’’, Esitas is your partner in the worldin order to increase efficiency for ourselves and our customers’’, Esitas is your partner in the world
transformer market.transformer market.
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
6
General DefinitionsGeneral Definitions
General definitions have been given according to International Standarts IEC 6OO44General definitions have been given according to International Standarts IEC 6OO44.
Instrument TransformerInstrument Transformer
A transformer intended to supply measuring instruments meters, protection relays and other similiar apparatus.A transformer intended to supply measuring instruments meters, protection relays and other similiar apparatus.
Applicable StandardsApplicable Standards
Our transformers comply with applicable national and international standards.Our transformers comply with applicable national and international standards.
Current TransformersCurrent Transformers
An instrument transformer in which the secondary current, in normal conditions of useAn instrument transformer in which the secondary current, in normal conditions of use, is substantially proportional to the primaryis substantially proportional to the primary
current and differs in phase from it by angle which is approximately zero for an appropriate direction of the connections.current and differs in phase from it by angle which is approximately zero for an appropriate direction of the connections.
It isolates the instrument and protection circuit from the primary side and protect the devices against overload according to theIt isolates the instrument and protection circuit from the primary side and protect the devices against overload according to the
overcurrent characteristics of the transformer. Current transformers can have several secondary windings with cores of identical ofovercurrent characteristics of the transformer. Current transformers can have several secondary windings with cores of identical of
different characteristics completely isolated from each other.different characteristics completely isolated from each other.
Measuring Current TransformerMeasuring Current Transformer
A current transformer intended to supply indicating instruments, integrating meters and similiar apparatus.A current transformer intended to supply indicating instruments, integrating meters and similiar apparatus.
Protective Current TransformerProtective Current Transformer
A current transformer intended to supply protective relays.A current transformer intended to supply protective relays.
Primary WindingPrimary Winding
The winding through which flows the current to be transformed.The winding through which flows the current to be transformed.
Secondary WindingSecondary Winding
The winding, which supplies the current circuits of measuring instruments, meters, relays or similiar devices.The winding, which supplies the current circuits of measuring instruments, meters, relays or similiar devices.
Secondary CircuitSecondary Circuit
The external circuit supplied by the secondary winding of a transformer.The external circuit supplied by the secondary winding of a transformer.
Rated Primary CurrentRated Primary Current
The value of the primary current on which the performance of the transformer is based.The value of the primary current on which the performance of the transformer is based.
Rated Secondary CurrentRated Secondary Current
The value of the secondary current on which the performance of the transformer is based.The value of the secondary current on which the performance of the transformer is based.
Rated Transformation RatioRated Transformation Ratio
The ratio of rated primary current to the rated secondary current (I1NThe ratio of rated primary current to the rated secondary current (I1N/I2N-i.e. 1OOI2N-i.e. 1OO/5A)5A)
Current Error (Ratio Error)Current Error (Ratio Error)
The error which a transformer introduces into the measurement of a current and which arises from the fact that the actualThe error which a transformer introduces into the measurement of a current and which arises from the fact that the actual
transformation ratio is not equal to the rated transformation ratio.transformation ratio is not equal to the rated transformation ratio.
The current error expressed in per cent is given by formula:The current error expressed in per cent is given by formula:
Current ErrorCurrent Error % (Kn Is - Ip)(Kn Is - Ip)
WhereWhere
Kn is the rated transformation ratio;Kn is the rated transformation ratio;
Ip is the actual primary currentIp is the actual primary current
Is is the actual secondary current when Ip is flowing under the conditions of measurements.Is is the actual secondary current when Ip is flowing under the conditions of measurements.
www.esitas.comwww.esitas.com
Accuracy ClassAccuracy Class
A designation assigned to a current transformer errors of which remain within specified limits under prescribed conditions of use.A designation assigned to a current transformer errors of which remain within specified limits under prescribed conditions of use.
BurdenBurden
The impedance of the secondary circuit in ohms and power-factor. The burden is usually expressed as the apparent power inThe impedance of the secondary circuit in ohms and power-factor. The burden is usually expressed as the apparent power in
voltamperes absorbed at a specified power-factor and at the rated secondary current.voltamperes absorbed at a specified power-factor and at the rated secondary current.
Rated BurdenRated Burden
The value of the burden on which the accuracy requirements are based on.The value of the burden on which the accuracy requirements are based on.
Rated OutputRated Output
The value of the apparent power (in voltamperes at a specified power-factor) which the transformer is intended to supply to theThe value of the apparent power (in voltamperes at a specified power-factor) which the transformer is intended to supply to the
secondary circuit at the rated secondary current and with rated burden connected to it.secondary circuit at the rated secondary current and with rated burden connected to it.
Rated Insulation LevelRated Insulation Level
The combination of voltage values which characterizes the insulation of a transformer with regard to its capability to whitstandThe combination of voltage values which characterizes the insulation of a transformer with regard to its capability to whitstand
dielectric stresses.dielectric stresses.
Rated FrequencyRated Frequency
This is the frequency for which the transformer is designed and given in Hz on the rating plate.This is the frequency for which the transformer is designed and given in Hz on the rating plate.
Rated Short-Time Thermal Current (Ith)Rated Short-Time Thermal Current (Ith)
The r.m.s. value of the primary current which a transformer will withstand for one second without suffering harmful effectsThe r.m.s. value of the primary current which a transformer will withstand for one second without suffering harmful effects
the secondary winding being short-circuited.the secondary winding being short-circuited.
Rated Dynamic Current (ldyn)Rated Dynamic Current (ldyn)
The peak value of the primary current which a transformer will withstand without being damaged electrically or mechanicallyThe peak value of the primary current which a transformer will withstand without being damaged electrically or mechanically
by the resulting electromagnetic forces the secondary winding being short-circuited.by the resulting electromagnetic forces the secondary winding being short-circuited.
Rated Continuous Thermal CurrentRated Continuous Thermal Current
The value of the current which can be permitted to flow continuously in the primary winding the secondary winding beingThe value of the current which can be permitted to flow continuously in the primary winding the secondary winding being
connected to the rated burden without temperature rise exceeding the values specified.connected to the rated burden without temperature rise exceeding the values specified.
7
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
8
CONNECTION DIAGRAMSCONNECTION DIAGRAMS
Single Ratio Current TransformersSingle Ratio Current Transformers
S1S1 S2S2 1S11S1 1S21S2 2S12S1 2S22S2 3S13S1
Multi CoresMulti Cores
3S23S2
P1P1 P1P1 P2P2P2P2
Single CoreSingle Core
Reconnection of Current TransformerReconnection of Current Transformer
In case of changeable ratios, it is possible to design the transformer with primary reconnection or secondary tapping;In case of changeable ratios, it is possible to design the transformer with primary reconnection or secondary tapping;
Primary ReconnectionPrimary Reconnection
Changeover will be done at the primaryChangeover will be done at the primary
side by using joint bars.side by using joint bars.
Can be used only for primary currents up to 2 x 6OOACan be used only for primary currents up to 2 x 6OOA
Secondary TappingSecondary Tapping
Changeover will be done at the secondary side.Changeover will be done at the secondary side.
S1S1 S2S2
P1P1 C1C1 C2C2 P2P2
C1 -C2 short circuited: low rated currentC1 -C2 short circuited: low rated current
P1 - C1 and P2 - C2 short circuited: high rated currentP1 - C1 and P2 - C2 short circuited: high rated current
S1 -S2 low rated currentS1 -S2 low rated current
S1 - S3 high rated currentS1 - S3 high rated current
P1P1
S1S1 S2S2 S3S3
P2P2
www.esitas.comwww.esitas.com
Safety Operation Conditions for Current TransformersSafety Operation Conditions for Current Transformers
9
- The secondary circuit of a current transformer must not be operated with an open - circuit.- The secondary circuit of a current transformer must not be operated with an open - circuit.
- The secondary winding of a current transformer which will not be used must- The secondary winding of a current transformer which will not be used must
be short - circuited and earthed as seen in Diagram-2be short - circuited and earthed as seen in Diagram-2
- When the secondary terminals are connected to the measuring or protection devices- When the secondary terminals are connected to the measuring or protection devices
one of the terminals should be earthed for safety as seen in Diagram-1.one of the terminals should be earthed for safety as seen in Diagram-1.
- For the transformer with reconnectable and - or tapped secondaries- For the transformer with reconnectable and - or tapped secondaries
unused terminals must be left open as seen in Diagram-3.unused terminals must be left open as seen in Diagram-3.
- The current transformers which have capacitive divider tap (Ck) must be connected to the indicator if the tap will- The current transformers which have capacitive divider tap (Ck) must be connected to the indicator if the tap will
not be used then it must be earthed.not be used then it must be earthed.
S1S1 S2S2
P1P1 P2P2
A
Diagram-1Diagram-1
S1S1 S2S2
P1P1 P2P2
Diagram-2Diagram-2
S1S1 S2S2
S3 openS3 open
P1P1 P2P2
A
Diagram-3Diagram-3
M.V. CURRENT TRANSFORMERS CONNECTION CLEARENCESM.V. CURRENT TRANSFORMERS CONNECTION CLEARENCES
a b
Insulation LevelInsulation Level
12kV12kV
24kV24kV
36kV36kV
a minimuma minimum
1OOmm1OOmm
19Omm19Omm
3O5mm3O5mm
b minimumb minimum
11Omm11Omm
21Omm21Omm
325mm325mm
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
1010
Technical DataTechnical Data
- Up to 3 cores- Up to 3 cores*
- On request with capacitive layer.- On request with capacitive layer.
- On request with barrier.- On request with barrier.
INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSINDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=3,6kV .............. 12kV BLOCK TYPES)(Um=3,6kV .............. 12kV BLOCK TYPES)
TYPESTYPES ATB 1O-BATB 1O-B ATB 1O-B2ATB 1O-B2 ATB 1O-B3ATB 1O-B3 ATB 1O-2ATB 1O-2
Operating voltage, Um (kV)Operating voltage, Um (kV)
Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV)
Rated frequency (Hz)Rated frequency (Hz)
Primary rated current (A)Primary rated current (A)
Primary reconnection (A)Primary reconnection (A)
Secondary rated current (A)Secondary rated current (A)
Metering classesMetering classes
Protection classesProtection classes
Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA)
Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA)
Short-time load (mechanical) (N)Short-time load (mechanical) (N)
Insulation classInsulation class
Ambient temperature (˚C)Ambient temperature (˚C)
Altitude (m)Altitude (m)
StandardStandard
Weight (approx.) (kg)Weight (approx.) (kg)
3,6 7,2 123,6 7,2 12
1O 2O 281O 2O 28
4O 6O 754O 6O 75
5O-6O5O-6O
5 - 25OO5 - 25OO
2 x 5 - 2 x 6OO2 x 5 - 2 x 6OO
1-51-5
O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1
5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1
max. 1OOO x Inmax. 1OOO x In
2,5 x lth2,5 x lth
5OOO5OOO
E
-25 ........... +4O-25 ........... +4O****
1OOO1OOO
According to the customer requirementsAccording to the customer requirements
2O - 252O - 25 28 - 3328 - 33 33 - 3633 - 36 3636
(On request 3OOOA 1.Oxln(On request 3OOOA 1.Oxln / Cont. &Cont. &
Insulation class B )Insulation class B )
On request operating voltage of 17,5 kV is available.On request operating voltage of 17,5 kV is available.
* For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility.
** It can be produced according to customer's specified ambient temperature.Please contact with ESiTAS for feasibility.It can be produced according to customer's specified ambient temperature.Please contact with ESiTAS for feasibility.
1111
-- All dimensions are in mm.All dimensions are in mm.
-- Tolerances are according to DIN 7168-g when not specified.Tolerances are according to DIN 7168-g when not specified.
-- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
-- Customer designed products are also available.Customer designed products are also available.
INDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGINDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWING
(Um=3,6kV .............. 12kV BLOCK TYPES)(Um=3,6kV .............. 12kV BLOCK TYPES)
TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm)
M5 (Secondary Terminal)M5 (Secondary Terminal)
M8 (Ground Terminal)M8 (Ground Terminal)
M12 (Primary Terminal)M12 (Primary Terminal)
min.
2.5
max.
3.5
15 2O
6O 7O
TYPESTYPES
ATB 1O-BATB 1O-B
ATB 1O-B2ATB 1O-B2
ATB 1O-B3ATB 1O-B3
ATB 1O-2ATB 1O-2
A B C D E F G H
355 155 22O 148 29O 125 27O
395 195 22O 148 33O 125 31O
2O
2O
455 255 22O 148 39O 125 37O 2O
355 155 22O 175 29O 15O 27O 2O
www.esitas.comwww.esitas.com
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
1212
Technical DataTechnical Data
- Up to 3 cores- Up to 3 cores*
- On request with capacitive layer.- On request with capacitive layer.
- On request with barrier.- On request with barrier.
INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSINDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=3,6kV ...... 12kV, 17,5 ...... 24kV NEW BLOCK TYPES)(Um=3,6kV ...... 12kV, 17,5 ...... 24kV NEW BLOCK TYPES)
* For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility.
** On request ATB 1O-BS operating voltage of 17,5kV is available.On request ATB 1O-BS operating voltage of 17,5kV is available.
*** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.
TYPESTYPES ATB 1O-BSATB 1O-BS ATB 2O-BSATB 2O-BS
Operating voltage, Um (kV)Operating voltage, Um (kV)
Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV)
Rated frequency (Hz)Rated frequency (Hz)
Primary rated current (A)Primary rated current (A)
Primary reconnection (A)Primary reconnection (A)
Secondary rated current (A)Secondary rated current (A)
Metering classesMetering classes
Protection classesProtection classes
Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA)
Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA)
Short-time load (mechanical) (N)Short-time load (mechanical) (N)
Insulation classInsulation class
Ambient temperature (˚C)Ambient temperature (˚C)
Altitude (m)Altitude (m)
StandardStandard
Weight (approx.) (kg)Weight (approx.) (kg)
3,6 7,2 123,6 7,2 12
1O 2O 281O 2O 28
4O 6O 754O 6O 75
17,5 2417,5 24
38 5O38 5O
95 12595 125
5O-6O5O-6O
5 - 25OO5 - 25OO
2 x 5 - 2 x 6OO2 x 5 - 2 x 6OO
1-51-5
O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1
5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1
max. 1OOO x Inmax. 1OOO x In
2,5 x lth2,5 x lth
5OOO5OOO
E
-25 ........... +4O-25 ........... +4O******
1OOO1OOO
According to the customer requirementsAccording to the customer requirements
2O - 252O - 25 3O3O
(On request 3OOOA 1.Oxln(On request 3OOOA 1.Oxln / Cont. &Cont. &
Insulation class B )Insulation class B )
**
1313
-- All dimensions are in mm.All dimensions are in mm.
-- Tolerances are according to DIN 7168-g when not specified.Tolerances are according to DIN 7168-g when not specified.
-- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
-- Customer designed products are also available.Customer designed products are also available.
INDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGINDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWING
(Um=3,6kV ...... 12kV, 17,5 ...... 24kV NEW BLOCK TYPES)(Um=3,6kV ...... 12kV, 17,5 ...... 24kV NEW BLOCK TYPES)
TYPESTYPES
ATB 1O-BSATB 1O-BS
ATB 2O-BSATB 2O-BS
A B C D E F G H I J
355 155 22O 148 299 135 -
355 155 28O 178 3OO 135 34O
125
15O
27O
28O
2O
2O
TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm)
M5 (Secondary Terminal)M5 (Secondary Terminal)
M8 (Ground Terminal)M8 (Ground Terminal)
M12 (Primary Terminal)M12 (Primary Terminal)
min.
2.5
max.
3.5
15 2O
6O 7O
8Omm will be8Omm will be
7Omm at7Omm at
ATB1O-BSATB1O-BS
www.esitas.comwww.esitas.com
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
1414
TYPESTYPES ATB 1O-1OATB 1O-1O ATB 1O-15ATB 1O-15
Operating voltage, Um (kV)Operating voltage, Um (kV)
Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV)
Rated frequency (Hz)Rated frequency (Hz)
Primary rated current (A)Primary rated current (A)
Primary reconnection (A)Primary reconnection (A)
Secondary rated current (A)Secondary rated current (A)
Metering classesMetering classes
Protection classesProtection classes
Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA)
Rated dynamic current (ldyn)Rated dynamic current (ldyn) (kA)(kA)
Short-time load (mechanical) (N)Short-time load (mechanical) (N)
Insulation classInsulation class
Ambient temperature (˚C)Ambient temperature (˚C)
Altitude (m)Altitude (m)
StandardStandard
Weight (approx.) (kg)Weight (approx.) (kg)
3,63,6 7,27,2 1212
1O1O 2O2O 2828
4O4O 6O6O 7575
5O-6O5O-6O
5-up to 125O5-up to 125O
2x5- 2x6OO2x5- 2x6OO
1-51-5
O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1
5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1
(max. 2OO x In)(max. 2OO x In)****
2,5 x lth2,5 x lth
5OOO5OOO
E
-25 ........... +4O-25 ........... +4O******
1OOO1OOO
According to the customer requirementsAccording to the customer requirements
1212 1717
On request operating voltage of 17,5 kV is available.On request operating voltage of 17,5 kV is available.
** For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility.
**** May vary according to requested primary current and core values.May vary according to requested primary current and core values.
****** It can be produced according to customer's specified ambient temperature. Please contact with ESiTAS for feasibility.It can be produced according to customer's specified ambient temperature. Please contact with ESiTAS for feasibility.
Technical DataTechnical Data
Types: ATB 1O-1OTypes: ATB 1O-1O
ATB 1O-15ATB 1O-15
- ATB 1O-1O up to 1 core- ATB 1O-1O up to 1 core*
- ATB 1O-15 up to 2 cores.- ATB 1O-15 up to 2 cores.*
- On request with capacitive layer.- On request with capacitive layer.
- On request with barrier.- On request with barrier.
INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSINDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=3,6kV .............. 12kV NARROW BLOCK TYPES)(Um=3,6kV .............. 12kV NARROW BLOCK TYPES)
1515
INDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.INDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGS TECHNICAL DRAWING
(Um=3,6kV .............. 12kV NARROW BLOCK TYPES)(Um=3,6kV .............. 12kV NARROW BLOCK TYPES)
TYPESTYPES
ATB 1O-1OATB 1O-1O
ATB 1O-15ATB 1O-15
A B C D E F G
33O 155 22O 148 125 27O 2O
33O 155 22O 148 125 27O 2O
TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm)
M5 (Secondary Terminal)M5 (Secondary Terminal)
M8 (Ground Terminal)M8 (Ground Terminal)
M12 (Primary Terminal)M12 (Primary Terminal)
min.
2.5
max.
3.5
15 2O
6O 7O
-- All dimensions are in mm.All dimensions are in mm.
-- Tolerances are according to DIN 7168-g when not specified.Tolerances are according to DIN 7168-g when not specified.
-- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
-- Customer designed products are also available.Customer designed products are also available.
www.esitas.comwww.esitas.com
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
1616
Technical DataTechnical Data
INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSINDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=17,5kV .............. 24kV BLOCK TYPES)(Um=17,5kV .............. 24kV BLOCK TYPES)
- Up to 3 cores.- Up to 3 cores.*
- On request with capacitive layer.- On request with capacitive layer.
- On request with barrier.- On request with barrier.
* For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility.
** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.
TYPESTYPES
Operating voltage, Um (kV)Operating voltage, Um (kV)
Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV)
Rated frequency (Hz)Rated frequency (Hz)
Primary rated current (A)Primary rated current (A)
Primary reconnection (A)Primary reconnection (A)
Secondary rated current (A)Secondary rated current (A)
Metering classesMetering classes
Protection classesProtection classes
Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA)
Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA)
Short-time load (mechanical) (N)Short-time load (mechanical) (N)
Insulation classInsulation class
Ambient temperature (˚C)Ambient temperature (˚C)
Altitude (m)Altitude (m)
StandardStandard
Weight (approx.) (kg)Weight (approx.) (kg)
17.5 2417.5 24
38 5O38 5O
95 12595 125
5O-6O5O-6O
5 - 25OO5 - 25OO
2 x 5 - 2 x 6OO2 x 5 - 2 x 6OO
1-51-5
O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1
5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1
max. 1OOO x Inmax. 1OOO x In
2,5 x lth2,5 x lth
5OOO5OOO
E
-25 ........... +4O-25 ........... +4O****
1OOO1OOO
According to the customer requirementsAccording to the customer requirements
3O3O 4242 4444 4444 5555 7O7O
ATB 2O-BATB 2O-B ATB 2O-B2ATB 2O-B2 ATB 2O-B4ATB 2O-B4 ATB 2O-3ATB 2O-3 ATB 2O-3BATB 2O-3B ATB 2O-3KATB 2O-3K
(On request 3OOOA 1.Oxln(On request 3OOOA 1.Oxln / Cont. &Cont. &
Insulation class B )Insulation class B )
INDOOR SUPPORT TYPE CAST RESIN INSULATEDINDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING
(Um=17,5kV .............. 24kV BLOCK TYPES)(Um=17,5kV .............. 24kV BLOCK TYPES)
1717
-- All dimensions are in mm.All dimensions are in mm.
-- Tolerances are according to DIN 7168-g when not specified.Tolerances are according to DIN 7168-g when not specified.
-- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
-- Customer designed products are also available.Customer designed products are also available.
455 197 28O 218 39O 195 19O 375 22
TYPESTYPES
ATB 2O-BATB 2O-B
ATB 2O-B2ATB 2O-B2
ATB 2O-B4ATB 2O-B4
ATB 2O-3ATB 2O-3
ATB 2O-3BATB 2O-3B
ATB 2O-3KATB 2O-3K
A B C D E F G H I
355 155 28O 178 29O 145 15O 28O 2O
355 155 28O 2O5 29O 145 18O 28O 17
355 155 28O 218 29O 145 19O 28O 17
455 197 28O 178 39O 195 15O 375 22
455 197 28O 2O5 39O 195 18O 375 22
TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm)
M5 (Secondary Terminal)M5 (Secondary Terminal)
M8 (Ground Terminal)M8 (Ground Terminal)
M12 (Primary Terminal)M12 (Primary Terminal)
min.
2.5
max.
3.5
15 2O
6O 7O
www.esitas.comwww.esitas.com
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
1818
Technical DataTechnical Data
Types: ATB 2O-3ATypes: ATB 2O-3A
ATB 2O-3BATB 2O-3B
INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSINDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=17,5kV .............. 24kV NEW BLOCK TYPES)(Um=17,5kV .............. 24kV NEW BLOCK TYPES)
- Up to 3 cores.- Up to 3 cores.*
- On request with capacitive layer.- On request with capacitive layer.
- On request with barrier.- On request with barrier.
* For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility.
** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.
TYPESTYPES
Operating voltage, Um (kV)Operating voltage, Um (kV)
Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV)
Rated frequency (Hz)Rated frequency (Hz)
Primary rated current (A)Primary rated current (A)
Primary reconnection (A)Primary reconnection (A)
Secondary rated current (A)Secondary rated current (A)
Metering classesMetering classes
Protection classesProtection classes
Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA)
Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA)
Short-time load (mechanical) (N)Short-time load (mechanical) (N)
Insulation classInsulation class
Ambient temperature (˚C)Ambient temperature (˚C)
Altitude (m)Altitude (m)
StandardStandard
Weight (approx.) (kg)Weight (approx.) (kg)
17.5 2417.5 24
38 5O38 5O
95 12595 125
5O-6O5O-6O
5 - 25OO5 - 25OO
2 x 5 - 2 x 6OO2 x 5 - 2 x 6OO
1-51-5
O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1
5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1
max. 1OOO x Inmax. 1OOO x In
2,5 x lth2,5 x lth
5OOO5OOO
E
-25 ........... +4O-25 ........... +4O****
1OOO1OOO
According to the customer requirementsAccording to the customer requirements
4444 5555
ATB 2O-3BATB 2O-3BATB 2O-3AATB 2O-3A
(On request 3OOOA 1.Oxln(On request 3OOOA 1.Oxln / Cont. &Cont. &
Insulation class B )Insulation class B )
INDOOR SUPPORT TYPE CAST RESIN INSULATEDINDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING
(Um=17,5kV .............. 24kV NEW BLOCK TYPES)(Um=17,5kV .............. 24kV NEW BLOCK TYPES)
1919
-- All dimensions are in mm.All dimensions are in mm.
-- Tolerances are according to DIN 7168-g when not specified.Tolerances are according to DIN 7168-g when not specified.
-- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
-- Customer designed products are also available.Customer designed products are also available.
TYPESTYPES
ATB 2O-3AATB 2O-3A
ATB 2O-3BATB 2O-3B
A B C D E F G H
455 28O 178 39O 14O 15O 375
455 28O 2O5 39O 14O 18O 375 2O
2O
TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm)
M5 (Secondary Terminal)M5 (Secondary Terminal)
M8 (Ground Terminal)M8 (Ground Terminal)
M12 (Primary Terminal)M12 (Primary Terminal)
min.
2.5
max.
3.5
15 2O
6O 7O
www.esitas.comwww.esitas.com
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
2020
Technical DataTechnical Data
Types: ATB 2O-1OTypes: ATB 2O-1O
ATB 2O-15ATB 2O-15
INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSINDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=17,5kV .............. 24kV NARROW BLOCK TYPES)(Um=17,5kV .............. 24kV NARROW BLOCK TYPES)
- ATB 2O-1O up to 1 core- ATB 2O-1O up to 1 core*
- ATB 2O-15 up to 2 cores.- ATB 2O-15 up to 2 cores.*
- On request with capacitive layer.- On request with capacitive layer.
- On request with barrier.- On request with barrier.
TYPESTYPES
Operating voltage, Um (kV)Operating voltage, Um (kV)
Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV)
Rated frequency (Hz)Rated frequency (Hz)
Primary rated current (A)Primary rated current (A)
Primary reconnection (A)Primary reconnection (A)
Secondary rated current (A)Secondary rated current (A)
Metering classesMetering classes
Protection classesProtection classes
Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA)
Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA)
Short-time load (mechanical) (N)Short-time load (mechanical) (N)
Insulation classInsulation class
Ambient temperature (˚C)Ambient temperature (˚C)
Altitude (m)Altitude (m)
StandardStandard
Weight (approx.) (kg)Weight (approx.) (kg)
17.5 2417.5 24
38 5O38 5O
95 12595 125
5O-6O5O-6O
5 up to 125O5 up to 125O
2 x 5 - 2 x 6OO2 x 5 - 2 x 6OO
1-51-5
O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1
5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1
(max. 3OO x In)(max. 3OO x In)****
2,5 x lth2,5 x lth
5OOO5OOO
E
-25 ........... +4O-25 ........... +4O******
1OOO1OOO
According to the customer requirementsAccording to the customer requirements
2222 3O3O
ATB 2O-15ATB 2O-15ATB 2O-1OATB 2O-1O
* For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility.
** May vary according to requested primary current and core values.May vary according to requested primary current and core values.
*** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.
INDOOR SUPPORT TYPE CAST RESIN INSULATEDINDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING
(Um=17,5kV .............. 24kV NARROW BLOCK TYPES)(Um=17,5kV .............. 24kV NARROW BLOCK TYPES)
2121
-- All dimensions are in mm.All dimensions are in mm.
-- Tolerances are according to DIN 7168-g when not specified.Tolerances are according to DIN 7168-g when not specified.
-- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
-- Customer designed products are also available.Customer designed products are also available.
TYPESTYPES
ATB 2O-1OATB 2O-1O
ATB 2O-15ATB 2O-15
A B C D E F G
335 155 28O 178 15O 28O 2O
335 155 28O 178 15O 28O 2O
TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm)
M5 (Secondary Terminal)M5 (Secondary Terminal)
M8 (Ground Terminal)M8 (Ground Terminal)
M12 (Primary Terminal)M12 (Primary Terminal)
min.
2.5
max.
3.5
15 2O
6O 7O
www.esitas.comwww.esitas.com
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
2222
Technical DataTechnical Data
INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSINDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=36kV BLOCK TYPES)(Um=36kV BLOCK TYPES)
- Up to 3 cores.- Up to 3 cores.*
- On request with capacitive layer.- On request with capacitive layer.
- On request with barrier.- On request with barrier.
* For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility.
** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.
TYPESTYPES
Operating voltage, Um (kV)Operating voltage, Um (kV)
Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV)
Rated frequency (Hz)Rated frequency (Hz)
Primary rated current (A)Primary rated current (A)
Primary reconnection (A)Primary reconnection (A)
Secondary rated current (A)Secondary rated current (A)
Metering classesMetering classes
Protection classesProtection classes
Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA)
Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA)
Short-time load (mechanical) (N)Short-time load (mechanical) (N)
Insulation classInsulation class
Ambient temperature (˚C)Ambient temperature (˚C)
Altitude (m)Altitude (m)
StandardStandard
Weight (approx.) (kg)Weight (approx.) (kg)
3636
7O7O
17O17O
5O-6O5O-6O
5 - 25OO5 - 25OO
2 x 5 - 2 x 6OO2 x 5 - 2 x 6OO
1-51-5
O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1
5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1
max. 1OOO x Inmax. 1OOO x In
2,5 x lth2,5 x lth
5OOO5OOO
E
-25 ........... +4O-25 ........... +4O****
1OOO1OOO
According to the customer requirementsAccording to the customer requirements
ATB 3O-SATB 3O-S ATB 3O-S1ATB 3O-S1 ATB 3O-1ATB 3O-1 ATB 3O-2ATB 3O-2 ATB 3O-3ATB 3O-3
(On request 3OOOA 1.Oxln(On request 3OOOA 1.Oxln / Cont. &Cont. &
Insulation class B )Insulation class B )
3535 3737 4O4O 4646 5151
INDOOR SUPPORT TYPE CAST RESIN INSULATEDINDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING
(Um=36kV BLOCK TYPES)(Um=36kV BLOCK TYPES)
2323
-- All dimensions are in mm.All dimensions are in mm.
- Tolerances are according to DIN 7168-g when not specified.Tolerances are according to DIN 7168-g when not specified.
- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
- Customer designed products are also available.Customer designed products are also available.
TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm)
M5 (Secondary Terminal)M5 (Secondary Terminal)
M8 (Ground Terminal)M8 (Ground Terminal)
M12 (Primary Terminal)M12 (Primary Terminal)
min.
2.5
max.
3.5
15 2O
6O 7O
TYPESTYPES
ATB 3O-SATB 3O-S
ATB 3O-S1ATB 3O-S1
ATB 3O-1ATB 3O-1
A B C D E F G H I J
385 17O 36O 255 25O 125 21O 225
385 17O 36O 255 27O 135 22O 225
385 17O 36O 255 27O 135 22O 225
3OO
3OO
3OO
2O
2O
2O
ATB 3O-2ATB 3O-2 385 17O 36O 255 31O 155 24O 225 3OO 2O
ATB 3O-3ATB 3O-3 455 21O 36O 255 389 195 249 225 375 2O
www.esitas.comwww.esitas.com
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
2424
Technical DataTechnical Data
INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSINDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=36kV NARROW BLOCK TYPES)(Um=36kV NARROW BLOCK TYPES)
- ATB 3O-4- ATB 3O-4, 3O-53O-5, 3O-1O up to 1 core.3O-1O up to 1 core.*
- ATB 3O-15 up to 2 cores.- ATB 3O-15 up to 2 cores.**
- On request with capacitive layer.- On request with capacitive layer.
- ATB 3O-1O & ATB 3O-15 with barrier on request.- ATB 3O-1O & ATB 3O-15 with barrier on request.
* For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility.
** May vary according to requested primary current and core values.May vary according to requested primary current and core values.
*** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.
5 - up to 6OO5 - up to 6OO
2x5 - 2x3OO2x5 - 2x3OO
5 - up to 125O5 - up to 125O
2x5 - 2x6OO2x5 - 2x6OO
TYPESTYPES
Operating voltage, Um (kV)Operating voltage, Um (kV)
Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV)
Rated frequency (Hz)Rated frequency (Hz)
Primary rated current (A)Primary rated current (A)
Primary reconnection (A)Primary reconnection (A)
Secondary rated current (A)Secondary rated current (A)
Metering classesMetering classes
Protection classesProtection classes
Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA)
3636
7O7O
17O17O
5O-6O5O-6O
1-51-5
O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1
5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1
Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA)
Short-time load (mechanical) (N)Short-time load (mechanical) (N)
Insulation classInsulation class
Ambient temperature (˚C)Ambient temperature (˚C)
Altitude (m)Altitude (m)
StandardStandard
Weight (approx.) (kg)Weight (approx.) (kg)
2,5 x lth2,5 x lth
5OOO5OOO
E
-25 ........... +4O-25 ........... +4O******
1OOO1OOO
According to the customer requirementsAccording to the customer requirements
2O2O 2222 2525 3535
ATB 3O-4ATB 3O-4 ATB 3O-5ATB 3O-5 ATB 3O-1OATB 3O-1O ATB 3O-15ATB 3O-15
max. 3OOxInmax. 3OOxIn**
(for 1(for 1
measurementmeasurement
core)core)
max. 4OOxInmax. 4OOxIn**
(for 1(for 1
measurementmeasurement
core)core)
max. 8OOxInmax. 8OOxIn**
(for 1(for 1
measurementmeasurement
core)core)
max. 3OOxInmax. 3OOxIn**
(for 2 cores)(for 2 cores)
INDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGINDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWING
(Um=36kV NARROW BLOCK TYPES)(Um=36kV NARROW BLOCK TYPES)
2525
-- All dimensions are in mm.All dimensions are in mm.
- Tolerances are according to DIN 7168-g when not specified.Tolerances are according to DIN 7168-g when not specified.
- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
- Customer designed products are also available.Customer designed products are also available.
TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm)
M5 (Secondary Terminal)M5 (Secondary Terminal)
M8 (Ground Terminal)M8 (Ground Terminal)
M 12 (Primary Terminal)M 12 (Primary Terminal)
min.
2.5
max.
3.5
15 2O
6O 7O
TYPESTYPES
ATB 3O-4ATB 3O-4
ATB 3O-5ATB 3O-5
ATB 3O-1OATB 3O-1O
ATB 3O-15ATB 3O-15
A B C D E F G H I J
385 17O 36O 255 2OO 1OO 18O 225
385 17O 36O 255 25O 125 21O 225
385 17O 36O 255 25O 125 21O 225
385 17O 36O 255 25O 125 21O 225
3OO
3OO
3OO
3OO
2O
2O
2O
2O
www.esitas.comwww.esitas.com
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
2626
Technical DataTechnical Data
Types: ATU 24Types: ATU 24
INDOOR SUPPORT TYPE CAST RESIN INSULATED NARROW TYPE CURRENT TRANSFORMERSINDOOR SUPPORT TYPE CAST RESIN INSULATED NARROW TYPE CURRENT TRANSFORMERS
(Um=7,2kV .......... 24kV BLOCK TYPES)(Um=7,2kV .......... 24kV BLOCK TYPES)
- Up to 2 cores.- Up to 2 cores.
* May vary according to requested primary current and core values.May vary according to requested primary current and core values.
** It can be produced according to customer’s specified ambient temperature. Please contact with ESITAS for feasibility.It can be produced according to customer’s specified ambient temperature. Please contact with ESITAS for feasibility.
Secondary rated current (A)Secondary rated current (A)
Primary reconnection (A)Primary reconnection (A)
Metering classesMetering classes
Protection classesProtection classes
Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA)
Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA)
Short-time load (mechanical) (N)Short-time load (mechanical) (N)
Insulation classInsulation class
Ambient temperature (˚C)Ambient temperature (˚C)
Altitude (m)Altitude (m)
StandardStandard
Weight (approx.) (kg)Weight (approx.) (kg)
1-51-5
O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1
5P- 1OP Acc. to IEC 6OO44-15P- 1OP Acc. to IEC 6OO44-1
1OO x In1OO x In*
2,5 x lth2,5 x lth
5OOO5OOO
E
-25............+4O-25............+4O****
1OOO1OOO
According to the customer requirementsAccording to the customer requirements
2424
TYPESTYPES
Operating voltage, Um (kV)Operating voltage, Um (kV)
Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV)
Rated frequency (Hz)Rated frequency (Hz)
Primary rated current (A)Primary rated current (A)
7,2 12 17,5 247,2 12 17,5 24
2O 28 38 5O2O 28 38 5O
6O 75 95 1256O 75 95 125
5O-6O5O-6O
1O - up to 8OO1O - up to 8OO
2x1O - 2x4OO2x1O - 2x4OO
ATU 24ATU 24
INDOOR SUPPORT TYPE CAST RESIN INSULATED NARROW TYPE C.T.’SINDOOR SUPPORT TYPE CAST RESIN INSULATED NARROW TYPE C.T.’S
TECHNICAL DRAWINGTECHNICAL DRAWING
(Um=7,2kV .......... 24kV BLOCK TYPES)(Um=7,2kV .......... 24kV BLOCK TYPES)
2727
-- All dimensions are in mm.All dimensions are in mm.
- Tolerances are according to DIN 7168-g when not specified.Tolerances are according to DIN 7168-g when not specified.
- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
- Customer designed products are also available.Customer designed products are also available.
www.esitas.comwww.esitas.com
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
2828
Technical DataTechnical Data
Types: ES24 C3-BTypes: ES24 C3-B
INDOOR SUPPORT TYPE CAST RESIN INSULATED SPECIAL TYPEINDOOR SUPPORT TYPE CAST RESIN INSULATED SPECIAL TYPE
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
(Um=7,2kV .......... 24kV BLOCK TYPES)
- Up to 2 cores.- Up to 2 cores.
* May vary according to requested primary current and core values.May vary according to requested primary current and core values.
** It can be produced according to customer’s specified ambient temperature. Please contact with ESITAS for feasibility.It can be produced according to customer’s specified ambient temperature. Please contact with ESITAS for feasibility.
Secondary rated current (A)Secondary rated current (A)
Primary reconnection (A)Primary reconnection (A)
Metering classesMetering classes
Protection classesProtection classes
Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA)
Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA)
Short-time load (mechanical) (N)Short-time load (mechanical) (N)
Insulation classInsulation class
Ambient temperatureAmbient temperature (˚C)(˚C)
Altitude (m)Altitude (m)
StandardStandard
Weight (approx.) (kg)Weight (approx.) (kg)
1-51-5
O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1
5P-1OP-PX Acc. to IEC 6OO44-15P-1OP-PX Acc. to IEC 6OO44-1
Up to 6OkAUp to 6OkA*
2,5 x lth2,5 x lth
5OOO5OOO
E
-25............+4O-25............+4O****
1OOO1OOO
According to the customer requirementsAccording to the customer requirements
2525
TYPESTYPES
Operating voltage, Um (kV)Operating voltage, Um (kV)
Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV)
Rated frequency (Hz)Rated frequency (Hz)
Primary rated current (A)Primary rated current (A)
7,2 12 17,5 247,2 12 17,5 24
2O 28 38 5O2O 28 38 5O
6O 75 95 1256O 75 95 125
5O-6O5O-6O
1O - up to 8OO1O - up to 8OO
2x1O - 2x4OO2x1O - 2x4OO
ES24 C3-BES24 C3-B
PES)
INDOOR SUPPORT TYPE CAST RESIN INSULATED SPECIAL TYPE C.T.’SINDOOR SUPPORT TYPE CAST RESIN INSULATED SPECIAL TYPE C.T.’S
TECHNICAL DRAWINGTECHNICAL DRAWING
(Um=7,2kV .......... 24kV BLOCK TYPES)(Um=7,2kV .......... 24kV BLOCK TYPES)
2929
-- All dimensions are in mm.All dimensions are in mm.
- Tolerances are according to DIN 7168-g when not specified.Tolerances are according to DIN 7168-g when not specified.
- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
- Customer designed products are also available.Customer designed products are also available.
www.esitas.comwww.esitas.com
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
3030
Technical DataTechnical Data
INDOOR POST BUSBAR TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSINDOOR POST BUSBAR TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=3,6kV ....................24kV)(Um=3,6kV ....................24kV)
- Up to 2 cores.- Up to 2 cores.*
* For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility.
** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.
Secondary rated current (A)Secondary rated current (A)
Metering classesMetering classes
Protection classesProtection classes
Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA)
Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA)
Short-time load (mechanical) (N)Short-time load (mechanical) (N)
Insulation classInsulation class
Ambient temperature (˚C)Ambient temperature (˚C)
Altitude (m)Altitude (m)
StandardStandard
Weight (approx.) (kg)Weight (approx.) (kg)
1-51-5
O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1
5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1
max. 1OOmax. 1OO
Practically UnlimitedPractically Unlimited
3OOO3OOO
E
-25 ........... +4O-25 ........... +4O****
1OOO1OOO
According to the customer requirementsAccording to the customer requirements
1919 3434
TYPESTYPES
Operating voltage, Um (kV)Operating voltage, Um (kV)
Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV)
Rated frequency (Hz)Rated frequency (Hz)
Primary rated current (A)Primary rated current (A)
3,6 7,2 123,6 7,2 12
1O 2O 281O 2O 28
4O 6O 754O 6O 75
17,5 2417,5 24
38 5O38 5O
95 12595 125
5O-6O5O-6O
8OO-3OOO8OO-3OOO 8OO-4OOO8OO-4OOO
ATD 1OATD 1O ATD 2OATD 2O
INDOORINDOOR POST BUSBARPOST BUSBAR TYPE CAST RESIN INSULATEDTYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING
(Um=3,6kV ..............24kV)(Um=3,6kV ..............24kV)
3131
-- All dimensions are in mm.All dimensions are in mm.
- Tolerance is DIN 7168-g .Tolerance is DIN 7168-g .
- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
- Customer designed products are also available.Customer designed products are also available.
TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm)
M5 (Secondary Terminal)M5 (Secondary Terminal)
min.
2.5
max.
3.5
TYPESTYPES
ATD 1OATD 1O
ATD 2OATD 2O
A B C D E F G H I
28O 1O2 342 214 215 235 158 155
28O 1O2 427 26O 26O 295 158 155
23
23
www.esitas.comwww.esitas.com
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
3232
Technical DataTechnical Data
INDOOR POST BUSBAR TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSINDOOR POST BUSBAR TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=3,6kV............24kV)(Um=3,6kV............24kV)
- Up to 3 cores.- Up to 3 cores.*
* For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility.
** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.
Secondary rated current (A)Secondary rated current (A)
Metering classesMetering classes
Protection classesProtection classes
Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA)
Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA)
Short-time load (mechanical) (N)Short-time load (mechanical) (N)
Insulation classInsulation class
Ambient temperature (˚C)Ambient temperature (˚C)
Altitude (m)Altitude (m)
StandardStandard
Weight (approx.) (kg)Weight (approx.) (kg)
1-51-5
O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1
5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1
max. 1OOmax. 1OO
Practically UnlimitedPractically Unlimited
3OOO3OOO
E
-25 ........... +4O-25 ........... +4O****
1OOO1OOO
According to the customer requirementsAccording to the customer requirements
3535 4O4O 3838
TYPESTYPES
Operating voltage, Um (kV)Operating voltage, Um (kV)
Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV)
Rated frequency (Hz)Rated frequency (Hz)
Primary rated current (A)Primary rated current (A)
3,6 7,2 12 17,53,6 7,2 12 17,5
1O 2O 28 381O 2O 28 38
4O 6O 75 954O 6O 75 95
17,5 2417,5 24
38 5O38 5O
95 12595 125
5O-6O5O-6O
8OO-4OOO8OO-4OOO
ATN 17ATN 17 ATN 24ATN 24ESO 17CESO 17C
3333
-- All dimensions are in mm.All dimensions are in mm.
- Tolerance is DIN 7168-g.Tolerance is DIN 7168-g.
- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
- Customer designed products are also available.Customer designed products are also available.
M5 (Secondary Terminal)M5 (Secondary Terminal) 2,5 3,5
TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) min. max.
INDOOR POST BUSBAR TYPE CAST RESIN INSULATEDINDOOR POST BUSBAR TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING
(Um=3,6kV............24kV)(Um=3,6kV............24kV)
ATN 17 (width 15Omm )ATN 17 (width 15Omm ) ATN 17ATN 17 (width 28Omm )(width 28Omm )
ATN 24ATN 24 ESO 17CESO 17C
www.esitas.comwww.esitas.com
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
3434
Technical DataTechnical Data
OUTDOOR DRY TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSOUTDOOR DRY TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=3,6kV ....................24kV)(Um=3,6kV ....................24kV)
- ATH 2O up to 1 core.- ATH 2O up to 1 core.*
- ATH 21 up to 2 cores.- ATH 21 up to 2 cores.*
- ATH 22 up to 3 cores.- ATH 22 up to 3 cores.*
* For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility.
Secondary rated current (A)Secondary rated current (A)
Primary reconnection (A)Primary reconnection (A)
Metering classesMetering classes
Protection classesProtection classes
Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA)
Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA)
Short-time load (mechanical) (N)Short-time load (mechanical) (N)
Insulation classInsulation class
Min. creepage distance (mm)Min. creepage distance (mm)
Altitude (m)Altitude (m)
StandardStandard
Weight (approx.) (kg)Weight (approx.) (kg)
1-51-5
O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1
5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1
max. 1OOO x Inmax. 1OOO x In
2,5 x lth2,5 x lth
24OO24OO
E
56O56O 825825 77O77O
According to the customer requirementsAccording to the customer requirements
According to the customer requirementsAccording to the customer requirements
2424 3535 7878
TYPESTYPES
Operating voltage, Um (kV)Operating voltage, Um (kV)
Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV)
Rated frequency (Hz)Rated frequency (Hz)
Primary rated current (A)Primary rated current (A)
3,6 7,2 123,6 7,2 12
1O 2O 281O 2O 28
4O 6O 754O 6O 75
17,5 2417,5 24
38 5O38 5O
95 12595 125
5O-6O5O-6O
5-125O5-125O 5-25OO5-25OO
2x5 - 2x4OO2x5 - 2x4OO 2x5 - 2x6OO2x5 - 2x6OO
ATH 2OATH 2O ATH 21ATH 21 ATH 22ATH 22
For the connectionFor the connection
of aluminium conductorsof aluminium conductors
steel reinforcedsteel reinforced
OUTDOOR DRY TYPE CAST RESIN INSULATEDOUTDOOR DRY TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING
(Um=3,6kV ....................24kV)(Um=3,6kV ....................24kV)
3535
-- All dimensions are in mm.All dimensions are in mm.
-- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
-- Customer designed products are also available.Customer designed products are also available.
TYPESTYPES
ATH 2OATH 2O
A B C D E F G H
245 1O5
max.
35O
max.
37O
max.
38O
max.
225
max.
34O
max.
415
22O 178 175 2O
ATH 21ATH 21 35O 165 3OO 27O 2OO 65
ATH 22ATH 22 4OO 195 37O 34O 25O 7O
M6 (Secondary Terminal)M6 (Secondary Terminal) 3 5
M12 (Primary & Ground Terminal)M12 (Primary & Ground Terminal) 6O 7O
TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) min. max.
www.esitas.comwww.esitas.com
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
3636
Technical DataTechnical Data
Types: ATH 3OTypes: ATH 3O
ATH 32ATH 32
OUTDOOR DRY TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSOUTDOOR DRY TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=36kV)(Um=36kV)
- ATH 3O up to 2 cores.- ATH 3O up to 2 cores.*
- ATH 32 up to 3 cores.- ATH 32 up to 3 cores.*
* For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility.
Secondary rated current (A)Secondary rated current (A)
Primary reconnection (A)Primary reconnection (A)
Metering classesMetering classes
Protection classesProtection classes
Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA)
Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA)
Short-time load (mechanical) (N)Short-time load (mechanical) (N)
Insulation classInsulation class
Min. creepage distance (mm)Min. creepage distance (mm)
Altitude (m)Altitude (m)
StandardStandard
Weight (approx.) (kg)Weight (approx.) (kg)
1-51-5
O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1
5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1
max. 1OOO x Inmax. 1OOO x In
2,5 x lth2,5 x lth
25OO25OO
E
114O114O
According to the customer requirementsAccording to the customer requirements
According to the customer requirementsAccording to the customer requirements
4747 8585
TYPESTYPES
Operating voltage, Um (kV)Operating voltage, Um (kV)
Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV)
Rated frequency (Hz)Rated frequency (Hz)
Primary rated current (A)Primary rated current (A)
3636
7O7O
17O17O
5O-6O5O-6O
5-25OO5-25OO
2x5 - 2x6OO2x5 - 2x6OO
ATH 3OATH 3O ATH 32ATH 32
For the connectionFor the connection
of aluminium conductorsof aluminium conductors
steel reinforcedsteel reinforced
OUTDOOR DRY TYPE CAST RESIN INSULATEDOUTDOOR DRY TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING
(Um=36kV)(Um=36kV)
3737
-- All dimensions are in mm.All dimensions are in mm.
- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
- Customer designed products are also available.Customer designed products are also available.
TYPESTYPES
ATH 3OATH 3O
A B C D E F G H
35O 165
max.
465
max.
477
max.
34O
max.
4O3
3OO 27O 2OO 65
ATH 32ATH 32 39O 19O 35O 32O 25O 65
M6 (Secondary Terminal)M6 (Secondary Terminal) 3 5
M12 (Primary & Ground Terminal)M12 (Primary & Ground Terminal) 6O 7O
TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) min. max.
www.esitas.comwww.esitas.com
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
3838
Technical DataTechnical Data
Types: ATH 3O-NTypes: ATH 3O-N
ATH 32-NATH 32-N
OUTDOOR DRY TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSOUTDOOR DRY TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=36kV)(Um=36kV)
- ATH 3O-N up to 2 cores.- ATH 3O-N up to 2 cores.*
- ATH 32-N up to 3 cores.- ATH 32-N up to 3 cores.*
* For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility.
Secondary rated current (A)Secondary rated current (A)
Primary reconnection (A)Primary reconnection (A)
Metering classesMetering classes
Protection classesProtection classes
Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA)
Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA)
Short-time load (mechanical) (N)Short-time load (mechanical) (N)
Insulation classInsulation class
Min. creepage distance (mm)Min. creepage distance (mm)
Altitude (m)Altitude (m)
StandardStandard
Weight (approx.) (kg)Weight (approx.) (kg)
1-51-5
O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1
5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1
max. 1OOO x Inmax. 1OOO x In
2,5 x lth2,5 x lth
25OO25OO
E
114O114O
According to the customer requirementsAccording to the customer requirements
According to the customer requirementsAccording to the customer requirements
4747 8585
TYPESTYPES
Operating voltage, Um (kV)Operating voltage, Um (kV)
Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV)
Rated frequency (Hz)Rated frequency (Hz)
Primary rated current (A)Primary rated current (A)
3636
7O7O
17O17O
5O-6O5O-6O
5-25OO5-25OO
2x5 - 2x6OO2x5 - 2x6OO
ATH 3O-NATH 3O-N ATH 32-NATH 32-N
For the connectionFor the connection
of aluminium conductorsof aluminium conductors
steel reinforcedsteel reinforced
OUTDOOR DRY TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGOUTDOOR DRY TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWING
(Um=36kV)(Um=36kV)
3939
-- All dimensions are in mm.All dimensions are in mm.
-- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
-- Customer designed products are also available.Customer designed products are also available.
TYPESTYPES
ATH 3O-NATH 3O-N
A B C D E F G H
35O 165
max.
465
max.
474
max.
34O
max.
4OO
3OO 27O 2OO 65
ATH 32-NATH 32-N 39O 173 35O 32O 25O 65
M6 (Secondary Terminal)M6 (Secondary Terminal) 3 5
M12 (PrimaryM12 (Primary TerminalTerminal) 6O 7O
TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) min. max.
www.esitas.comwww.esitas.com
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
4040
Technical DataTechnical Data
Types: ATH 52Types: ATH 52
OUTDOOR DRY TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSOUTDOOR DRY TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=52kV)(Um=52kV)
- Up to 2 cores.- Up to 2 cores.*
* For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility.
Secondary rated current (A)Secondary rated current (A)
Primary reconnection (A)Primary reconnection (A)
Metering classesMetering classes
Protection classesProtection classes
Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA)
Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA)
Short-time load (mechanical) (N)Short-time load (mechanical) (N)
Insulation classInsulation class
Min. creepage distance (mm)Min. creepage distance (mm)
Altitude (m)Altitude (m)
StandardStandard
Weight (approx.) (kg)Weight (approx.) (kg)
1-51-5
O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1
5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1
max. 1OOO x Inmax. 1OOO x In
2,5 x lth2,5 x lth
25OO25OO
E
16OO16OO
According to the customer requirementsAccording to the customer requirements
According to the customer requirementsAccording to the customer requirements
14O14O
TYPESTYPES
Operating voltage, Um (kV)Operating voltage, Um (kV)
Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV)
Rated frequency (Hz)Rated frequency (Hz)
Primary rated current (A)Primary rated current (A)
5252
9595
25O25O
5O-6O5O-6O
5-25OO5-25OO
2x5 - 2x6OO2x5 - 2x6OO
ATH 52ATH 52
For the connectionFor the connection
of aluminium conductorsof aluminium conductors
steel reinforcedsteel reinforced
OUTDOOR DRY TYPE CAST RESIN INSULATEDOUTDOOR DRY TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING
(Um=52kV )(Um=52kV )
4141
-- All dimensions are in mm.All dimensions are in mm.
- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
- Customer designed products are also available.Customer designed products are also available.
M6 (Secondary Terminal)M6 (Secondary Terminal) 3 5
M12 (Primary & Ground Terminal)M12 (Primary & Ground Terminal) 6O 7O
TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) min. max.
www.esitas.comwww.esitas.com
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
Technical DataTechnical Data
Types: KAPTypes: KAP
INDOOR KAP TYPE (CABLE TYPE) CAST RESIN INSULATEDINDOOR KAP TYPE (CABLE TYPE) CAST RESIN INSULATED
ANDAND
ENCLOSED BY PLASTIC COVERENCLOSED BY PLASTIC COVER
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
(Um=O,72kV)
- Width 35- Width 35, 55mm up to 1 core.55mm up to 1 core.*
- Width 95- Width 95, 115mm up to 2 cores.115mm up to 2 cores.*
* For more cores, please contact with ESITAS for feasibility.For more cores, please contact with ESITAS for feasibility.
** It can be produced according to customer’s specified ambient temperature. Please contact with ESITAS for feasibility.It can be produced according to customer’s specified ambient temperature. Please contact with ESITAS for feasibility.
)
4444
1-51-5
O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1
5P- 1OP; Acc. to IEC 6OO44-15P- 1OP; Acc. to IEC 6OO44-1
max. 1OOmax. 1OO
Practically unlimitedPractically unlimited
E
-25............+4O-25............+4O****
1OOO1OOO
According to the customer requirementsAccording to the customer requirements
TYPESTYPES
Secondary rated current (A)Secondary rated current (A)
Metering classesMetering classes
Protection classesProtection classes
Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA)
Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA)
Insulation classInsulation class
Ambient temperatureAmbient temperature (˚C)(˚C)
Altitude (m)Altitude (m)
StandardStandard
Operating voltage, Um (kV)Operating voltage, Um (kV)
Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV)
Rated frequency (Hz)Rated frequency (Hz)
Primary rated currentPrimary rated current (A)(A)
O,72O,72
3
-
5O-6O5O-6O
4O ........... 3OOO4O ........... 3OOO
KAPKAP
* All dimensions are in mm.All dimensions are in mm.
INDOOR KAP TYPE (CABLE TYPE) CAST RESIN INSULATED AND ENCLOSED BY PLASTIC COVERINDOOR KAP TYPE (CABLE TYPE) CAST RESIN INSULATED AND ENCLOSED BY PLASTIC COVER
C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING (Um=O,72kV)(Um=O,72kV)
NONO TYPETYPE IDID ODOD H K O A B C
1 KAP-4OKAP-4O/19O-3519O-35 4O4O 19O19O 241241 3535 119119 15O15O 13O13O -
2 KAP-4OKAP-4O/19O-5519O-55 4O4O 19O19O 241241 5555 119119 15O15O 13O13O 2525
3 KAP-4OKAP-4O/19O-9519O-95 4O4O 19O19O 241241 9595 119119 15O15O 13O13O 4O4O
4 KAP-4OKAP-4O/19O-11519O-115 4O4O 19O19O 241241 115115 119119 17O17O 15O15O 4O4O
5 KAP-6OKAP-6O/19O-3519O-35 6O6O 19O19O 241241 3535 119119 15O15O 13O13O -
6 KAP-6OKAP-6O/19O-5519O-55 6O6O 19O19O 241241 5555 119119 15O15O 13O13O 2525
7 KAP-6OKAP-6O/19O-9519O-95 6O6O 19O19O 241241 9595 119119 15O15O 13O13O 4O4O
8 KAP-6OKAP-6O/19O-11519O-115 6O6O 19O19O 241241 115115 119119 17O17O 15O15O 4O4O
9 KAP-8OKAP-8O/19O-3519O-35 8O8O 19O19O 241241 3535 119119 15O15O 13O13O -
1O1O KAP-8OKAP-8O/19O-5519O-55 8O8O 19O19O 241241 5555 119119 15O15O 13O13O 2525
1111 KAP-8OKAP-8O/19O-9519O-95 8O8O 19O19O 241241 9595 119119 15O15O 13O13O 4O4O
1212 KAP-8OKAP-8O/19O-11519O-115 8O8O 19O19O 241241 115115 119119 17O17O 15O15O 4O4O
1313 KAP-4OKAP-4O/21O-3521O-35 4O4O 21O21O 261261 3535 129129 15O15O 13O13O -
1414 KAP-4OKAP-4O/21O-5521O-55 4O4O 21O21O 261261 5555 129129 15O15O 13O13O 2525
1515 KAP-4OKAP-4O/21O-9521O-95 4O4O 21O21O 261261 9595 129129 15O15O 13O13O 4O4O
1616 KAP-4OKAP-4O/21O-11521O-115 4O4O 21O21O 261261 115115 129129 17O17O 15O15O 4O4O
1717 KAP-6OKAP-6O/21O-3521O-35 6O6O 21O21O 261261 3535 129129 15O15O 13O13O -
1818 KAP-6OKAP-6O/21O-5521O-55 6O6O 21O21O 261261 5555 129129 15O15O 13O13O 2525
1919 KAP-6OKAP-6O/21O-9521O-95 6O6O 21O21O 261261 9595 129129 15O15O 13O13O 4O4O
2O2O KAP-6OKAP-6O/21O-11521O-115 6O6O 21O21O 261261 115115 129129 17O17O 15O15O 4O4O
2121 KAP-8OKAP-8O/21O-3521O-35 8O8O 21O21O 261261 3535 129129 15O15O 13O13O -
2222 KAP-8OKAP-8O/21O-5521O-55 8O8O 21O21O 261261 5555 129129 15O15O 13O13O 2525
2323 KAP-8OKAP-8O/21O-9521O-95 8O8O 21O21O 261261 9595 129129 15O15O 13O13O 4O4O
2424 KAP-8OKAP-8O/21O-11521O-115 8O8O 21O21O 261261 115115 129129 17O17O 15O15O 4O4O
NONO TYPETYPE IDID ODOD H K O A B C
2525 KAP-4OKAP-4O/25O-3525O-35 4O4O 25O25O 3O13O1 3535 149149 15O15O 13O13O -
2626 KAP-4OKAP-4O/25O-5525O-55 4O4O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525
2727 KAP-4OKAP-4O/25O-9525O-95 4O4O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O
2828 KAP-4OKAP-4O/25O-11525O-115 4O4O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O
2929 KAP-6OKAP-6O/25O-3525O-35 6O6O 25O25O 3O13O1 3535 149149 15O15O 13O13O -
3O3O KAP-6OKAP-6O/25O-5525O-55 6O6O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525
3131 KAP-6OKAP-6O/25O-9525O-95 6O6O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O
3232 KAP-6OKAP-6O/25O-11525O-115 6O6O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O
3333 KAP-8OKAP-8O/25O-3525O-35 8O8O 25O25O 3O13O1 3535 149149 15O15O 13O13O -
3434 KAP-8OKAP-8O/25O-5525O-55 8O8O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525
3535 KAP-8OKAP-8O/25O-9525O-95 8O8O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O
3636 KAP-8OKAP-8O/25O-11525O-115 8O8O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O
3737 KAP-1OOKAP-1OO/25O-3525O-35 1OO1OO 25O25O 3O13O1 3535 149149 15O15O 13O13O -
3838 KAP-1OOKAP-1OO/25O-5525O-55 1OO1OO 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525
3939 KAP-1OOKAP-1OO/25O-9525O-95 1OO1OO 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O
4O4O
=
KAP-1OOKAP-1OO/25O-11525O-115 1OO1OO 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O
4141 KAP-12OKAP-12O/25O-5525O-55 12O12O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525
4242 KAP-12OKAP-12O/25O-9525O-95 12O12O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O
4343 KAP-12OKAP-12O/25O-11525O-115 12O12O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O
4444 KAP-15OKAP-15O/25O-5525O-55 15O15O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525
4545 KAP-15OKAP-15O/25O-9525O-95 15O15O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O
4646 KAP-15OKAP-15O/25O-11525O-115 15O15O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O
4747 KAP-1OOKAP-1OO/19O-5519O-55 1OO1OO 19O19O 241241 5555 119119 15O15O 13O13O 2525
4848 KAP-1OOKAP-1OO/19O-9519O-95 1OO1OO 19O19O 241241 9595 119119 15O15O 13O13O 4O4O
4949 KAP-1OOKAP-1OO/19O-11519O-115 1OO1OO 19O19O 241241 115115 119119 17O17O 15O15O 4O4O
5O5O KAP-17OKAP-17O/25O-5525O-55 17O17O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525
5151 KAP-17OKAP-17O/25O-9525O-95 17O17O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O
5252 KAP-17OKAP-17O/25O-11525O-115 17O17O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O
KAP TYPES (DIMENSIONS)KAP TYPES (DIMENSIONS)*
KAP TYPE ( With Horizontal Mounted Plates)KAP TYPE ( With Horizontal Mounted Plates)
CURRENT TRANSFORMERCURRENT TRANSFORMER
As can be seen In the below tables there are various dimensions ofAs can be seen In the below tables there are various dimensions of
KAP Types. Please contact with ESiTAS for feasibility of required transformer'sKAP Types. Please contact with ESiTAS for feasibility of required transformer's
which have different ratiowhich have different ratio, classclass, burden and dimensions.burden and dimensions.
! Attention : Transformers which have 35mm height ( K)Attention : Transformers which have 35mm height ( K),
there Is only one connection plate.there Is only one connection plate.
M5 (Secondary Terminal)M5 (Secondary Terminal) 2,5 3,5
TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) min. max.
4545
www.esitas.comwww.esitas.com
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
* All dimensions are in mm.All dimensions are in mm.
INDOOR KAP TYPE (CABLE TYPE) CAST RESIN INSULATED AND ENCLOSED BY PLASTIC COVERINDOOR KAP TYPE (CABLE TYPE) CAST RESIN INSULATED AND ENCLOSED BY PLASTIC COVER
C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING (Um=O,72kV)(Um=O,72kV)
KAP TYPES (DIMENSIONS)KAP TYPES (DIMENSIONS)*
KAP TYPE ( With Vertical Mounted Plates)KAP TYPE ( With Vertical Mounted Plates)
CURRENT TRANSFORMERCURRENT TRANSFORMER
As can be seen In the below tables there are various dimensions ofAs can be seen In the below tables there are various dimensions of
KAP Types. Please contact with ESiTAS for feasibility of required transformer'sKAP Types. Please contact with ESiTAS for feasibility of required transformer's
which have different ratio, class, burden and dimensions.which have different ratio, class, burden and dimensions.
M5 (Secondary Terminal)M5 (Secondary Terminal) 2,5 3,5
TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) min. max.
4646
NONO TYPETYPE IDID ODOD H K O A B C
1 KAP-4OKAP-4O/19O-3519O-35 4O4O 19O19O 241241 3535 119119 15O15O 13O13O 4O4O
2 KAP-4OKAP-4O/19O-5519O-55 4O4O 19O19O 241241 5555 119119 15O15O 13O13O 2525
3 KAP-4OKAP-4O/19O-9519O-95 4O4O 19O19O 241241 9595 119119 15O15O 13O13O 4O4O
4 KAP-4OKAP-4O/19O-11519O-115 4O4O 19O19O 241241 115115 119119 17O17O 15O15O 4O4O
5 KAP-6OKAP-6O/19O-3519O-35 6O6O 19O19O 241241 3535 119119 15O15O 13O13O 4O4O
6 KAP-6OKAP-6O/19O-5519O-55 6O6O 19O19O 241241 5555 119119 15O15O 13O13O 2525
7 KAP-6OKAP-6O/19O-9519O-95 6O6O 19O19O 241241 9595 119119 15O15O 13O13O 4O4O
8 KAP-6OKAP-6O/19O-11519O-115 6O6O 19O19O 241241 115115 119119 17O17O 15O15O 4O4O
9 KAP-8OKAP-8O/19O-3519O-35 8O8O 19O19O 241241 3535 119119 15O15O 13O13O 4O4O
1O1O KAP-8OKAP-8O/19O-5519O-55 8O8O 19O19O 241241 5555 119119 15O15O 13O13O 2525
1111 KAP-8OKAP-8O/19O-9519O-95 8O8O 19O19O 241241 9595 119119 15O15O 13O13O 4O4O
1212 KAP-8OKAP-8O/19O-11519O-115 8O8O 19O19O 241241 115115 119119 17O17O 15O15O 4O4O
1313 KAP-4OKAP-4O/21O-3521O-35 4O4O 21O21O 261261 3535 129129 15O15O 13O13O 4O4O
1414 KAP-4OKAP-4O/21O-5521O-55 4O4O 21O21O 261261 5555 129129 15O15O 13O13O 2525
1515 KAP-4OKAP-4O/21O-9521O-95 4O4O 21O21O 261261 9595 129129 15O15O 13O13O 4O4O
1616 KAP-4OKAP-4O/21O-11521O-115 4O4O 21O21O 261261 115115 129129 17O17O 15O15O 4O4O
1717 KAP-6OKAP-6O/21O-3521O-35 6O6O 21O21O 261261 3535 129129 15O15O 13O13O 4O4O
1818 KAP-6OKAP-6O/21O-5521O-55 6O6O 21O21O 261261 5555 129129 15O15O 13O13O 2525
1919 KAP-6OKAP-6O/21O-9521O-95 6O6O 21O21O 261261 9595 129129 15O15O 13O13O 4O4O
2O2O KAP-6OKAP-6O/21O-11521O-115 6O6O 21O21O 261261 115115 129129 17O17O 15O15O 4O4O
2121 KAP-8OKAP-8O/21O-3521O-35 8O8O 21O21O 261261 3535 129129 15O15O 13O13O 4O4O
2222 KAP-8OKAP-8O/21O-5521O-55 8O8O 21O21O 261261 5555 129129 15O15O 13O13O 2525
2323 KAP-8OKAP-8O/21O-9521O-95 8O8O 21O21O 261261 9595 129129 15O15O 13O13O 4O4O
2424 KAP-8OKAP-8O/21O-11521O-115 8O8O 21O21O 261261 115115 129129 17O17O 15O15O 4O4O
NONO TYPETYPE IDID ODOD H K O A B C
2525 KAP-4OKAP-4O/25O-3525O-35 4O4O 25O25O 3O13O1 3535 149149 15O15O 13O13O 4O4O
2626 KAP-4OKAP-4O/25O-5525O-55 4O4O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525
2727 KAP-4OKAP-4O/25O-9525O-95 4O4O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O
2828 KAP-4OKAP-4O/25O-11525O-115 4O4O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O
2929 KAP-6OKAP-6O/25O-3525O-35 6O6O 25O25O 3O13O1 3535 149149 15O15O 13O13O 4O4O
3O3O KAP-6OKAP-6O/25O-5525O-55 6O6O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525
3131 KAP-6OKAP-6O/25O-9525O-95 6O6O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O
3232 KAP-6OKAP-6O/25O-11525O-115 6O6O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O
3333 KAP-8OKAP-8O/25O-3525O-35 8O8O 25O25O 3O13O1 3535 149149 15O15O 13O13O 4O4O
3434 KAP-8OKAP-8O/25O-5525O-55 8O8O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525
3535 KAP-8OKAP-8O/25O-9525O-95 8O8O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O
3636 KAP-8OKAP-8O/25O-11525O-115 8O8O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O
3737 KAP-1OOKAP-1OO/25O-3525O-35 1OO1OO 25O25O 3O13O1 3535 149149 15O15O 13O13O 4O4O
3838 KAP-1OOKAP-1OO/25O-5525O-55 1OO1OO 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525
3939 KAP-1OOKAP-1OO/25O-9525O-95 1OO1OO 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O
4O4O
=
KAP-1OOKAP-1OO/25O-11525O-115 1OO1OO 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O
4141 KAP-12OKAP-12O/25O-5525O-55 12O12O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525
4242 KAP-12OKAP-12O/25O-9525O-95 12O12O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O
4343 KAP-12OKAP-12O/25O-11525O-115 12O12O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O
4444 KAP-15OKAP-15O/25O-5525O-55 15O15O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525
4545 KAP-15OKAP-15O/25O-9525O-95 15O15O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O
4646 KAP-15OKAP-15O/25O-11525O-115 15O15O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O
4747 KAP-1OOKAP-1OO/19O-5519O-55 1OO1OO 19O19O 241241 5555 119119 15O15O 13O13O 2525
4848 KAP-1OOKAP-1OO/19O-9519O-95 1OO1OO 19O19O 241241 9595 119119 15O15O 13O13O 4O4O
4949 KAP-1OOKAP-1OO/19O-11519O-115 1OO1OO 19O19O 241241 115115 119119 17O17O 15O15O 4O4O
5O5O KAP-17OKAP-17O/25O-5525O-55 17O17O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525
5151 KAP-17OKAP-17O/25O-9525O-95 17O17O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O
5252 KAP-17OKAP-17O/25O-11525O-115 17O17O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O
- Inside Diameters: 8O- Inside Diameters: 8O / 1OO1OO / 12O12O
Technical DataTechnical Data
Types: A-KAPTypes: A-KAP
INDOOR A-KAP TYPE (SPLIT TYPE) CAST RESIN INSULATEDINDOOR A-KAP TYPE (SPLIT TYPE) CAST RESIN INSULATED
ANDAND
ENCLOSED BY PLASTIC COVERENCLOSED BY PLASTIC COVER
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
(Um=O,72kV)(Um=O,72kV)
* It can be produced according to customer’s specified ambient temperature. Please contact with ESITAS for feasibility.It can be produced according to customer’s specified ambient temperature. Please contact with ESITAS for feasibility. 4747
1-51-5
O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1
5P- 1OP; Acc. to IEC 6OO44-15P- 1OP; Acc. to IEC 6OO44-1
max. 1OOmax. 1OO
Practically unlimitedPractically unlimited
E
-25............+4O-25............+4O*
1OOO1OOO
According to the customer requirementsAccording to the customer requirements
TYPESTYPES
Secondary rated current (A)Secondary rated current (A)
Metering classesMetering classes
Protection classesProtection classes
Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA)
Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA)
Insulation classInsulation class
Ambient temperatureAmbient temperature (˚C)(˚C)
Altitude (m)Altitude (m)
StandardStandard
Operating voltage, Um (kV)Operating voltage, Um (kV)
Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV)
Rated frequency (Hz)Rated frequency (Hz)
Primary rated currentPrimary rated current (A)(A)
O,72O,72
3
-
5O-6O5O-6O
5O ........... 2OOO5O ........... 2OOO
A-KAPA-KAP
www.esitas.comwww.esitas.com
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
* All dimensions are in mm.All dimensions are in mm.
INDOOR A-KAP TYPE (SPLIT TYPE) CAST RESIN INSULATED AND ENCLOSED BY PLASTIC COVERINDOOR A-KAP TYPE (SPLIT TYPE) CAST RESIN INSULATED AND ENCLOSED BY PLASTIC COVER
C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING (Um=O,72kV)(Um=O,72kV)
M5 (Secondary Terminal)M5 (Secondary Terminal) 2,5 3,5
TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) min. max.
NONO A
1 8O8O
1OO1OO
12O12O
2
3
4848
4949
RING TYPE CURRENT TRANSFORMERSRING TYPE CURRENT TRANSFORMERS
(Um=O,72kV)(Um=O,72kV)
INDOOR RING TYPESINDOOR RING TYPES
BUSHING TYPESBUSHING TYPES
OUTDOOR RING TYPESOUTDOOR RING TYPES
- Cable type.- Cable type.
- Insulated by cast resin.- Insulated by cast resin.
- Applicable for measurement and protection purposes.- Applicable for measurement and protection purposes.
- For power transformers.- For power transformers.
- Suitable for operation under oil continuous 13O- Suitable for operation under oil continuous 13O˚C.C.
- Insulated by Insulation paper or Polyester tape.- Insulated by Insulation paper or Polyester tape.
- Applicable for measurement and protection purposes.- Applicable for measurement and protection purposes.
- Dimensions : According to the customer requirements.Dimensions : According to the customer requirements.
- Standards : According to the customer requirements.Standards : According to the customer requirements.
- Please contact with ESITAS for feasibility of required transformer's which have different ratio, class, burden and dimensions.Please contact with ESITAS for feasibility of required transformer's which have different ratio, class, burden and dimensions.
www.esitas.comwww.esitas.com
CURRENT TRANSFORMERSCURRENT TRANSFORMERS
5050
Technical DataTechnical Data
Types: LPCT-115Types: LPCT-115
INDOOR TYPE LPCTINDOOR TYPE LPCT
(Low Power Current Transformer) (Cable Type)(Low Power Current Transformer) (Cable Type)
(Um=O, 72kV)(Um=O, 72kV)
- LPCT-115 is defining low power current transformer with- LPCT-115 is defining low power current transformer with
voltage output in compliance with IEC 6OO44-8.voltage output in compliance with IEC 6OO44-8.
- It is designed for measuring nominal currents of 5A to- It is designed for measuring nominal currents of 5A to
125O A with ratio 1OOA125O A with ratio 1OOA / 22,5mV. Thus it should be used with a22,5mV. Thus it should be used with a
digital relay which have 1OOAdigital relay which have 1OOA // 22,5mV input with LPCT.22,5mV input with LPCT.
- Esitas LPCT Set is composed of three LPCT and one digital- Esitas LPCT Set is composed of three LPCT and one digital
relay. In case of preffered set without relay, Esitas has to berelay. In case of preffered set without relay, Esitas has to be
informed about the relay that will be usedinformed about the relay that will be used,
- The sensor is delivered with cable which is between 5m - 8m- The sensor is delivered with cable which is between 5m - 8m
upon customer request.upon customer request.
Advantages :Advantages :
-Same transformer is usable for nominal currents of 5A to 125OA.-Same transformer is usable for nominal currents of 5A to 125OA.
- Accurracy warranty throughout the range :- Accurracy warranty throughout the range :
•• Protection : 5A-4OkA ; class 5PProtection : 5A-4OkA ; class 5P
•• Measuring: 1OOA-125OA; class O,5 (class O,75 for 2OA, class 1,5 for 5A).Measuring: 1OOA-125OA; class O,5 (class O,75 for 2OA, class 1,5 for 5A).
Simple Assembly :Simple Assembly :
- Ready for connection secondary cables.- Ready for connection secondary cables.
- Simple connection with insulated cable for all types cubicles.- Simple connection with insulated cable for all types cubicles.
Safety Operation :Safety Operation :
- Openable secondary circuit under load.- Openable secondary circuit under load.
cable between 5m - 8mcable between 5m - 8m
upon customer request.upon customer request.
Class of protectionClass of protection
Class of measuringClass of measuring
Accuracy limit factor (Kalf)Accuracy limit factor (Kalf)
Rated short - time current (kARated short - time current (kA / 1s)1s)
Insulation level (kV)Insulation level (kV)
Frequency (Hz)Frequency (Hz)
5P5P
15O15O
4O4O
O,72O,72 / 33 / --
5O - 6O5O - 6O
2
TYPESTYPES
StandardStandard
Minimum primary curent (A)Minimum primary curent (A)
Rated primary current (A)Rated primary current (A)
Rated secondary voltage (mV)Rated secondary voltage (mV)
Rated maximum primary current (A)Rated maximum primary current (A)
IEC 6OO44-8IEC 6OO44-8
5
1OO1OO
22,522,5
125O125O
O,5 (1OOA - 125OA), O,75 (2OA), 1,5 (5A)O,5 (1OOA - 125OA), O,75 (2OA), 1,5 (5A)
LPCT - 115LPCT - 115
5151
Technical DataTechnical Data
Types: LPCT-16OTypes: LPCT-16O
INDOOR TYPE LPCTINDOOR TYPE LPCT
(Low Power Current Transformer) (Cable Type)(Low Power Current Transformer) (Cable Type)
(Um=O, 72kV)(Um=O, 72kV)
- LPCT-16O is defining low power current transformer with- LPCT-16O is defining low power current transformer with
voltage output in compliance with IEC 6OO44-8.voltage output in compliance with IEC 6OO44-8.
- It is designed for measuring nominal currents of 5A to- It is designed for measuring nominal currents of 5A to
2OOO A with ratio 1OOA2OOO A with ratio 1OOA / 22,5mV. Thus it should be used with a22,5mV. Thus it should be used with a
digital relay which have 1OOAdigital relay which have 1OOA // 22,5mV input with LPCT.22,5mV input with LPCT.
- Esitas LPCT Set is composed of three LPCT and one digital- Esitas LPCT Set is composed of three LPCT and one digital
relay. In case of preffered set without relay, Esitas has to berelay. In case of preffered set without relay, Esitas has to be
informed about the relay that will be usedinformed about the relay that will be used,
- The sensor is delivered with cable which is between 5m - 8m- The sensor is delivered with cable which is between 5m - 8m
upon customer request.upon customer request.
Advantages :Advantages :
-Same transformer is usable for nominal currents of 5A to 2OOOA.-Same transformer is usable for nominal currents of 5A to 2OOOA.
- Accurracy warranty throughout the range :- Accurracy warranty throughout the range :
•• Protection : 5A-4OkA ; class 5PProtection : 5A-4OkA ; class 5P
•• Measuring: 1OOA-2OOOA; class O,5 (class O,75 for 2OA, class 1,5 for 5A).Measuring: 1OOA-2OOOA; class O,5 (class O,75 for 2OA, class 1,5 for 5A).
Simple Assembly :Simple Assembly :
- Ready for connection secondary cables.- Ready for connection secondary cables.
- Simple connection with insulated cable for all types cubicles.- Simple connection with insulated cable for all types cubicles.
Safety Operation :Safety Operation :
- Openable secondary circuit under load.- Openable secondary circuit under load. cable between 5m - 8mcable between 5m - 8m
upon customer request.upon customer request.
Class of protectionClass of protection
Class of measuringClass of measuring
Accuracy limit factor (Kalf)Accuracy limit factor (Kalf)
Rated short - time current (kARated short - time current (kA / 1s)1s)
Insulation level (kV)Insulation level (kV)
Frequency (Hz)Frequency (Hz)
Burden (Rbr)Burden (Rbr)
5P5P
4OO4OO
4O4O
O,72O,72 / 33 / --
5O - 6O5O - 6O
2
TYPESTYPES
StandardStandard
Minimum primary curent (A)Minimum primary curent (A)
Rated primary current (A)Rated primary current (A)
Rated secondary voltage (mV)Rated secondary voltage (mV)
Rated maximum primary current (A)Rated maximum primary current (A)
IEC 6OO44-8IEC 6OO44-8
5
1OO1OO
22,522,5
2OOO2OOO
O,5 (1OOA - 2OOOA), O,75 (2OA), 1,5 (5A)O,5 (1OOA - 2OOOA), O,75 (2OA), 1,5 (5A)
LPCT - 16OLPCT - 16O
www.esitas.comwww.esitas.com
VOLTAGE TRANSFORMERSVOLTAGE TRANSFORMERS
Voltage TransformersVoltage Transformers
An instrument transformer in which the secondary voltage, in normal conditions of use, is substantially proportional to the primaryAn instrument transformer in which the secondary voltage, in normal conditions of use, is substantially proportional to the primary
voltage and differs in phase from it by an angle which is approximately zero for an appropriate direction of thevoltage and differs in phase from it by an angle which is approximately zero for an appropriate direction of the connections.connections.
It isolates the primary side rated voltage from the connected instruments and protection circuits and convert the primaryIt isolates the primary side rated voltage from the connected instruments and protection circuits and convert the primary
voltage into a measurable secondary voltage, which is true in magnitude and phase.voltage into a measurable secondary voltage, which is true in magnitude and phase.
Primary WindingPrimary Winding
The winding to which the voltage to be transformed is applied.The winding to which the voltage to be transformed is applied.
Secondary WindingSecondary Winding
The winding, which supplies the voltage circuits of measuring instruments, meters, relays or similar apparatus.The winding, which supplies the voltage circuits of measuring instruments, meters, relays or similar apparatus.
Rated Primary VoltageRated Primary Voltage
The value of the primary voltage, which appears in the designation of the transformer and on which its performance is based.The value of the primary voltage, which appears in the designation of the transformer and on which its performance is based.
Rated Secondary VoltageRated Secondary Voltage
The value of the secondary voltage, which appears in the designation of the transformer and on which its performanceThe value of the secondary voltage, which appears in the designation of the transformer and on which its performance isis based.based.
Rated Transformation RatioRated Transformation Ratio
The ratio of the rated primary to the rated secondary voltage.The ratio of the rated primary to the rated secondary voltage.
Voltage Error (Ratio Error)Voltage Error (Ratio Error)
The error which a transformer introduces into the measurement of a voltage and which arises when the actual transformationThe error which a transformer introduces into the measurement of a voltage and which arises when the actual transformation
ratio is not equal to the transformation ratio.ratio is not equal to the transformation ratio.
The voltage error, expressed in per cent, is given by the formula:The voltage error, expressed in per cent, is given by the formula:
Voltage ErrorVoltage Error % =
WhereWhere
Kn is the rated transformation ratio;Kn is the rated transformation ratio;
Up is the actual primary voltage;Up is the actual primary voltage;
Us is the actual secondary voltage when Up is applied under the conditions of measurement.Us is the actual secondary voltage when Up is applied under the conditions of measurement.
Accuracy ClassAccuracy Class
A designation assigned to a voltage transformer, the errors of which remain within specified limits under prescribed conditions of use.A designation assigned to a voltage transformer, the errors of which remain within specified limits under prescribed conditions of use.
BurdenBurden
The admittance of the secondary circuit expressed in siemens and power factor (lagging or leading)The admittance of the secondary circuit expressed in siemens and power factor (lagging or leading)
Rated BurdenRated Burden
The value of the burden on which the accuracy requirements are based on.The value of the burden on which the accuracy requirements are based on.
Rated OutputRated Output
The value of apparent power (in voltamperes at a specified power - factor), which the transformer is intended to supply to theThe value of apparent power (in voltamperes at a specified power - factor), which the transformer is intended to supply to the
secondary circuit at the rated secondary voltage and with rated burden, connected to it.secondary circuit at the rated secondary voltage and with rated burden, connected to it.
Rated Insulation LevelRated Insulation Level
The combination of voltage values which characterizes the isolation of a transformer with regard to its capability to withstandThe combination of voltage values which characterizes the isolation of a transformer with regard to its capability to withstand
dielectric stresses.dielectric stresses.
Rated Voltage FactorRated Voltage Factor
The multiplying factor to be applied to the rated primary voltage to determine the maximum voltage at which a transformer mustThe multiplying factor to be applied to the rated primary voltage to determine the maximum voltage at which a transformer must
comply with the relevant thermal requirements for a specified time and with the relevant accuracy requirements.comply with the relevant thermal requirements for a specified time and with the relevant accuracy requirements.
Kn Us - UpKn Us - Up
UpUp
x1OOx1OO
5454
CONNECTION DIAGRAMSCONNECTION DIAGRAMS
a n a n dada dndn
Single Pole insulatedSingle Pole insulated
voltage transformervoltage transformer
with an open delta windingwith an open delta winding
(e.g. 11OOO(e.g. 11OOO/√/√3: 1OO3: 1OO/√/√3V - 1OO3V - 1OO/3V)3V)
Double pole insulatedDouble pole insulated
voltage transformervoltage transformer
(e.g. 11OOO: 1OOV)(e.g. 11OOO: 1OOV)
It can be required for multi secondary winding and changeable ratios.It can be required for multi secondary winding and changeable ratios.
A A NN
Single Pole insulatedSingle Pole insulated
voltage transformervoltage transformer
(e.g. 11OOO(e.g. 11OOO/√/√3: 1OO3: 1OO/√/√3V)3V)
V-Connection of Two Double Pole Insulated Voltage TransformersV-Connection of Two Double Pole Insulated Voltage Transformers
Safety Operation Conditions for Voltage TransformersSafety Operation Conditions for Voltage Transformers
-When the Secondary terminals are connected to the measuring or protection devices, one of the terminals should be earthed for-When the Secondary terminals are connected to the measuring or protection devices, one of the terminals should be earthed for
safety as seen in Diagram-1.safety as seen in Diagram-1.
a b
a b
A B A B
a b
A B
R S T
sr t
A B
a
b
V
5555
Diagram-1Diagram-1
www.esitas.comwww.esitas.com
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş
akım trafosu, gerilim trafosu esitaş

Contenu connexe

Tendances

Abb+ +presentacion+descagadores+de+sobre+tension+-+bolivia+-+mayo+2013
Abb+ +presentacion+descagadores+de+sobre+tension+-+bolivia+-+mayo+2013Abb+ +presentacion+descagadores+de+sobre+tension+-+bolivia+-+mayo+2013
Abb+ +presentacion+descagadores+de+sobre+tension+-+bolivia+-+mayo+2013
Manuel Pochet
 
Generator Protection
Generator ProtectionGenerator Protection
Generator Protection
Priten Vasa
 

Tendances (20)

Condition monitoring of rotating electrical machines
Condition monitoring of rotating electrical machinesCondition monitoring of rotating electrical machines
Condition monitoring of rotating electrical machines
 
128 electrical power-protection_guide
128 electrical power-protection_guide128 electrical power-protection_guide
128 electrical power-protection_guide
 
FEAM Enclosures - Hazardous Area & Explosion Proof Enclosures (ATEX, IECEx, I...
FEAM Enclosures - Hazardous Area & Explosion Proof Enclosures (ATEX, IECEx, I...FEAM Enclosures - Hazardous Area & Explosion Proof Enclosures (ATEX, IECEx, I...
FEAM Enclosures - Hazardous Area & Explosion Proof Enclosures (ATEX, IECEx, I...
 
Circuit breaker, Types of circuit breaker & different CB related questions
Circuit breaker, Types of circuit breaker & different CB related questionsCircuit breaker, Types of circuit breaker & different CB related questions
Circuit breaker, Types of circuit breaker & different CB related questions
 
Ieee generator protection
Ieee generator protectionIeee generator protection
Ieee generator protection
 
Relays
  Relays  Relays
Relays
 
Catalog Metasol Susol ACB LS technical
Catalog Metasol Susol ACB LS technicalCatalog Metasol Susol ACB LS technical
Catalog Metasol Susol ACB LS technical
 
Insulation Resistance Test
Insulation Resistance TestInsulation Resistance Test
Insulation Resistance Test
 
MICOM P 632
MICOM P 632MICOM P 632
MICOM P 632
 
SF6 CIRCUIT BREAKER
SF6 CIRCUIT BREAKERSF6 CIRCUIT BREAKER
SF6 CIRCUIT BREAKER
 
PE UNIT IV - INVERTERS.pptx
PE UNIT IV - INVERTERS.pptxPE UNIT IV - INVERTERS.pptx
PE UNIT IV - INVERTERS.pptx
 
ISOLATORS.pptx
ISOLATORS.pptxISOLATORS.pptx
ISOLATORS.pptx
 
Generator Voltage control
Generator Voltage controlGenerator Voltage control
Generator Voltage control
 
2017 2 tutorial-ac_hv_circuit_breakers_dufournet
2017 2 tutorial-ac_hv_circuit_breakers_dufournet2017 2 tutorial-ac_hv_circuit_breakers_dufournet
2017 2 tutorial-ac_hv_circuit_breakers_dufournet
 
SLD-LINE LENGTH-NAMEPLATE DETAILS OF 765/400/220KV EQUIPMENT DETAILS-TYPES OF...
SLD-LINE LENGTH-NAMEPLATE DETAILS OF 765/400/220KV EQUIPMENT DETAILS-TYPES OF...SLD-LINE LENGTH-NAMEPLATE DETAILS OF 765/400/220KV EQUIPMENT DETAILS-TYPES OF...
SLD-LINE LENGTH-NAMEPLATE DETAILS OF 765/400/220KV EQUIPMENT DETAILS-TYPES OF...
 
Abb+ +presentacion+descagadores+de+sobre+tension+-+bolivia+-+mayo+2013
Abb+ +presentacion+descagadores+de+sobre+tension+-+bolivia+-+mayo+2013Abb+ +presentacion+descagadores+de+sobre+tension+-+bolivia+-+mayo+2013
Abb+ +presentacion+descagadores+de+sobre+tension+-+bolivia+-+mayo+2013
 
SWITCH GEAR & PROTECTIVE DEVICE (EEN-437)
SWITCH GEAR & PROTECTIVE DEVICE (EEN-437)SWITCH GEAR & PROTECTIVE DEVICE (EEN-437)
SWITCH GEAR & PROTECTIVE DEVICE (EEN-437)
 
Powerpoint presentation on SF6 circuit breaker
Powerpoint presentation on SF6 circuit breakerPowerpoint presentation on SF6 circuit breaker
Powerpoint presentation on SF6 circuit breaker
 
Transformer asset management
Transformer asset managementTransformer asset management
Transformer asset management
 
Generator Protection
Generator ProtectionGenerator Protection
Generator Protection
 

En vedette

WALLPAPER quick sheet for site
WALLPAPER quick sheet for siteWALLPAPER quick sheet for site
WALLPAPER quick sheet for site
Nathan Vaughan
 
Presentation of project proposal and design brief
Presentation of project proposal and design briefPresentation of project proposal and design brief
Presentation of project proposal and design brief
Brandon Cooper
 
2 conceptos de 2 do orden o nociones históricas y como estos se gradúa a lo l...
2 conceptos de 2 do orden o nociones históricas y como estos se gradúa a lo l...2 conceptos de 2 do orden o nociones históricas y como estos se gradúa a lo l...
2 conceptos de 2 do orden o nociones históricas y como estos se gradúa a lo l...
esteba damian
 

En vedette (20)

La web
La webLa web
La web
 
RF Dresses PPT
RF Dresses PPTRF Dresses PPT
RF Dresses PPT
 
Acknowledgement
AcknowledgementAcknowledgement
Acknowledgement
 
Доклад «Приминение адаптивного дизайна при подборе дозы препарата нового поко...
Доклад «Приминение адаптивного дизайна при подборе дозы препарата нового поко...Доклад «Приминение адаптивного дизайна при подборе дозы препарата нового поко...
Доклад «Приминение адаптивного дизайна при подборе дозы препарата нового поко...
 
Доклад «Применение адаптивного дизайна при сравнении двух ДПП-4 ингибиторов»
Доклад «Применение адаптивного дизайна при сравнении двух ДПП-4 ингибиторов»Доклад «Применение адаптивного дизайна при сравнении двух ДПП-4 ингибиторов»
Доклад «Применение адаптивного дизайна при сравнении двух ДПП-4 ингибиторов»
 
WALLPAPER quick sheet for site
WALLPAPER quick sheet for siteWALLPAPER quick sheet for site
WALLPAPER quick sheet for site
 
Integrated Intelligent Transportation Systems (ITS)
Integrated Intelligent Transportation Systems (ITS)Integrated Intelligent Transportation Systems (ITS)
Integrated Intelligent Transportation Systems (ITS)
 
Ogechi A Carl-Onyeukwu
Ogechi A  Carl-OnyeukwuOgechi A  Carl-Onyeukwu
Ogechi A Carl-Onyeukwu
 
Uso del videojuego en el aula.
Uso del videojuego en el aula.Uso del videojuego en el aula.
Uso del videojuego en el aula.
 
Presentation
PresentationPresentation
Presentation
 
Presentation of project proposal and design brief
Presentation of project proposal and design briefPresentation of project proposal and design brief
Presentation of project proposal and design brief
 
Qualifications
QualificationsQualifications
Qualifications
 
Planificación del marketing
Planificación del marketingPlanificación del marketing
Planificación del marketing
 
2 conceptos de 2 do orden o nociones históricas y como estos se gradúa a lo l...
2 conceptos de 2 do orden o nociones históricas y como estos se gradúa a lo l...2 conceptos de 2 do orden o nociones históricas y como estos se gradúa a lo l...
2 conceptos de 2 do orden o nociones históricas y como estos se gradúa a lo l...
 
Cnc processing stampings parts provider
Cnc processing stampings parts providerCnc processing stampings parts provider
Cnc processing stampings parts provider
 
Xpert 2016-new-low
Xpert 2016-new-lowXpert 2016-new-low
Xpert 2016-new-low
 
Personal Persona Project
Personal Persona ProjectPersonal Persona Project
Personal Persona Project
 
Clinical trial protocol: strategy for success
Clinical trial protocol: strategy for successClinical trial protocol: strategy for success
Clinical trial protocol: strategy for success
 
Nowshads CV
Nowshads CVNowshads CV
Nowshads CV
 
Chapter I Introduction
Chapter I IntroductionChapter I Introduction
Chapter I Introduction
 

Similaire à akım trafosu, gerilim trafosu esitaş

Servo stabilizer manufacturers
Servo stabilizer manufacturersServo stabilizer manufacturers
Servo stabilizer manufacturers
tecmax
 
Report on Industrial Visit at Pahartali Textile and Hosiery Mills of M.M. Isp...
Report on Industrial Visit at Pahartali Textile and Hosiery Mills of M.M. Isp...Report on Industrial Visit at Pahartali Textile and Hosiery Mills of M.M. Isp...
Report on Industrial Visit at Pahartali Textile and Hosiery Mills of M.M. Isp...
Ekram Bin Mamun
 

Similaire à akım trafosu, gerilim trafosu esitaş (20)

Pragati pt cataloge
Pragati pt catalogePragati pt cataloge
Pragati pt cataloge
 
Original NPN Bipolar Transistor 2SC3423 C3423 3423 TO-126 New Toshiba
Original NPN Bipolar Transistor 2SC3423 C3423 3423 TO-126 New ToshibaOriginal NPN Bipolar Transistor 2SC3423 C3423 3423 TO-126 New Toshiba
Original NPN Bipolar Transistor 2SC3423 C3423 3423 TO-126 New Toshiba
 
Lighting Transformers in Pune - Starlit Electricals
Lighting Transformers in Pune - Starlit ElectricalsLighting Transformers in Pune - Starlit Electricals
Lighting Transformers in Pune - Starlit Electricals
 
Zero Voltage Switching Converters
Zero Voltage Switching ConvertersZero Voltage Switching Converters
Zero Voltage Switching Converters
 
Original NPN Transistor 2SC5949 5949 TO-3P New Toshiba
Original NPN Transistor 2SC5949 5949 TO-3P New ToshibaOriginal NPN Transistor 2SC5949 5949 TO-3P New Toshiba
Original NPN Transistor 2SC5949 5949 TO-3P New Toshiba
 
Solid state relay_catalog
Solid state relay_catalogSolid state relay_catalog
Solid state relay_catalog
 
Sheetal Corporation, Vadodara, Electrical Products
Sheetal Corporation, Vadodara, Electrical ProductsSheetal Corporation, Vadodara, Electrical Products
Sheetal Corporation, Vadodara, Electrical Products
 
02- Manual Motor Starter - Fuji Electric
02- Manual Motor Starter - Fuji Electric02- Manual Motor Starter - Fuji Electric
02- Manual Motor Starter - Fuji Electric
 
Original NPN 2SC5171 C5171 TO-220F New Toshiba
Original NPN 2SC5171 C5171 TO-220F New ToshibaOriginal NPN 2SC5171 C5171 TO-220F New Toshiba
Original NPN 2SC5171 C5171 TO-220F New Toshiba
 
Differential Current Protection of Transformer using Arduino
Differential Current Protection of Transformer using ArduinoDifferential Current Protection of Transformer using Arduino
Differential Current Protection of Transformer using Arduino
 
Zeni Products Presentation 2022
Zeni Products Presentation 2022 Zeni Products Presentation 2022
Zeni Products Presentation 2022
 
Aresster
AressterAresster
Aresster
 
ntpc ppt
ntpc pptntpc ppt
ntpc ppt
 
Traxon Cove Light AC Data Injector Specification
Traxon Cove Light AC Data Injector SpecificationTraxon Cove Light AC Data Injector Specification
Traxon Cove Light AC Data Injector Specification
 
Servo stabilizer manufacturers
Servo stabilizer manufacturersServo stabilizer manufacturers
Servo stabilizer manufacturers
 
Report on Industrial Visit at Pahartali Textile and Hosiery Mills of M.M. Isp...
Report on Industrial Visit at Pahartali Textile and Hosiery Mills of M.M. Isp...Report on Industrial Visit at Pahartali Textile and Hosiery Mills of M.M. Isp...
Report on Industrial Visit at Pahartali Textile and Hosiery Mills of M.M. Isp...
 
R. Sanghavi Mercantile Pvt. Ltd, Mumbai, Circuit Breakers
R. Sanghavi Mercantile Pvt. Ltd, Mumbai, Circuit BreakersR. Sanghavi Mercantile Pvt. Ltd, Mumbai, Circuit Breakers
R. Sanghavi Mercantile Pvt. Ltd, Mumbai, Circuit Breakers
 
Catalog Motor CB Fuji Electric
Catalog Motor CB Fuji ElectricCatalog Motor CB Fuji Electric
Catalog Motor CB Fuji Electric
 
IRJET - Designing of 1 Phase 5KVA Servo Stabilizer with Isolation Transformer
IRJET - Designing of 1 Phase 5KVA Servo Stabilizer with Isolation TransformerIRJET - Designing of 1 Phase 5KVA Servo Stabilizer with Isolation Transformer
IRJET - Designing of 1 Phase 5KVA Servo Stabilizer with Isolation Transformer
 
Company Profile of Tirupati Transformers Pvt Ltd
Company Profile of Tirupati Transformers Pvt LtdCompany Profile of Tirupati Transformers Pvt Ltd
Company Profile of Tirupati Transformers Pvt Ltd
 

Dernier

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
ssuser89054b
 
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
dharasingh5698
 
notes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.pptnotes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.ppt
MsecMca
 
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night StandCall Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
amitlee9823
 

Dernier (20)

Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
 
Thermal Engineering Unit - I & II . ppt
Thermal Engineering  Unit - I & II . pptThermal Engineering  Unit - I & II . ppt
Thermal Engineering Unit - I & II . ppt
 
Roadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and RoutesRoadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and Routes
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.ppt
 
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performance
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
 
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELL
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELLPVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELL
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELL
 
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
 
notes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.pptnotes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.ppt
 
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
 
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night StandCall Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
 
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
 
NFPA 5000 2024 standard .
NFPA 5000 2024 standard                                  .NFPA 5000 2024 standard                                  .
NFPA 5000 2024 standard .
 
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordCCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
 
Intze Overhead Water Tank Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank  Design by Working Stress - IS Method.pdfIntze Overhead Water Tank  Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank Design by Working Stress - IS Method.pdf
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
 
Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPT
 

akım trafosu, gerilim trafosu esitaş

  • 2. Company ProfileCompany Profile M.V. Current TransformersM.V. Current Transformers Technical Information About Current TransformersTechnical Information About Current Transformers ATB 1O-BATB 1O-B ATB 1O-BSATB 1O-BS / ATB 2O-BSATB 2O-BS ATB 1O-1OATB 1O-1O // ATB 1O-15ATB 1O-15 ATB 2O-BATB 2O-B ATB 2O-3AATB 2O-3A / ATB 2O-3BATB 2O-3B ATATB 2O-1OB 2O-1O / ATB 2O-15ATB 2O-15 ATB 3O-SATB 3O-S ATB 3O-4ATB 3O-4 / ATB 3O-5ATB 3O-5 / ATB 3O-1OATB 3O-1O ATU 24ATU 24 ES24 C3-BES24 C3-B ATD 1OATD 1O / 2O2O ATN 17ATN 17 // ESO 17CESO 17C // ATN 24ATN 24 ATH 2OATH 2O / 2121 // 2222 ATH 3OATH 3O / 3232 ATH 3O-NATH 3O-N / 32-N32-N ATH 52ATH 52 L.V Current TransformersL.V Current Transformers KAP TypeKAP Type A-Kap Type (Split Type)A-Kap Type (Split Type) Indoor & Outdoor Ring TypeIndoor & Outdoor Ring Type LPCT 115LPCT 115 LPCT 16OLPCT 16O Voltage TransformersVoltage Transformers Technical Information About Voltage TransformersTechnical Information About Voltage Transformers VTB 1O-SVTB 1O-S / VTB 1O-KVTB 1O-K / VTB 2OVTB 2O / VTB 2O-KVTB 2O-K VTB 3O-KVTB 3O-K VT 2O-BVT 2O-B // VTB 3OVTB 3O 2 VTB 1O2 VTB 1O / 2 VTB 2O2 VTB 2O 2 VT 2O-B2 VT 2O-B / 2 VTB 32 VTB 3OO / 2 VT 4O-2OO2 VT 4O-2OO VTB 1O-KFVTB 1O-KF / VTB 2O-KFVTB 2O-KF / VTB 3O-KFVTB 3O-KF ES 12 VR-FES 12 VR-F / ES 24 V2-FES 24 V2-F VTB 1O-SFVTB 1O-SF / VTB 1O-EFVTB 1O-EF/ VTB 2O-FVTB 2O-F VTB 3O-FVTB 3O-F ES 17 V3ES 17 V3 ES 24 V2-BES 24 V2-B ES 24 V1ES 24 V1 VTU 24VTU 24 VTH 2OVTH 2O / VTH 3OVTH 3O VTH 2O-NVTH 2O-N / VTH 3O-NVTH 3O-N 2VTH 2O2VTH 2O / 2VTH 3O2VTH 3O 2VTH 2O-N2VTH 2O-N / 2VTH 3O-N2VTH 3O-N InsulatorsInsulators Technical Information About InsulatorsTechnical Information About Insulators Special ProductsSpecial Products Page 2Page 2 Page 5Page 5 Page 6Page 6 Page 1OPage 1O Page 12Page 12 Page 14Page 14 Page 16Page 16 Page 18Page 18 Page 2OPage 2O Page 22Page 22 Page 24Page 24 Page 26Page 26 Page 28Page 28 Page 3OPage 3O Page 32Page 32 Page 34Page 34 Page 36Page 36 Page 38Page 38 Page 4OPage 4O Page 44Page 44 Page 47Page 47 Page 49Page 49 Page 5OPage 5O Page 51Page 51 Page 53Page 53 Page 54Page 54 Page 58Page 58 Page 6OPage 6O Page 62Page 62 Page 64Page 64 Page 66Page 66 Page 68Page 68 Page 7OPage 7O Page 72Page 72 Page 74Page 74 Page 76Page 76 Page 78Page 78 Page 8OPage 8O Page 82Page 82 Page 84Page 84 Page 86Page 86 Page 88Page 88 Page 9OPage 9O Page 93Page 93 Page 94Page 94 Page 1OOPage 1OO CONTENTSCONTENTS Page 43Page 43
  • 3. 22 GENERAL INFORMATION ABOUT ESITAS GROUP COMPANIESGENERAL INFORMATION ABOUT ESITAS GROUP COMPANIES Mission StatementMission Statement ‘’ As Esitas Group, we aim to be the main supplier of the market leaders in the world transformer‘’ As Esitas Group, we aim to be the main supplier of the market leaders in the world transformer industry and to be a permanent player in the developing countries; by keeping our leader positionindustry and to be a permanent player in the developing countries; by keeping our leader position in domestic market in instrument transformers and increasing awareness of our products in thein domestic market in instrument transformers and increasing awareness of our products in the global market, together with continuously improving our existent quality and introducing innovati-global market, together with continuously improving our existent quality and introducing innovati- ons in order to increase efficiency for ourselves and our customers.ons in order to increase efficiency for ourselves and our customers. Group Companies:Group Companies: Esitas Brand has been in the transformer industry more than 25 years. Esitas Group CompaniesEsitas Brand has been in the transformer industry more than 25 years. Esitas Group Companies have been producing and serving the electrical products and contacting businesses with twohave been producing and serving the electrical products and contacting businesses with two factories specializing in their markets.factories specializing in their markets. ESITAS ELEKTRIKESITAS ELEKTRIK is the parent company of the group located in Istanbul, Turkey producesis the parent company of the group located in Istanbul, Turkey produces and sells Low and Medium Voltage Instrument Transformers (both Current - Voltage and Indoor-and sells Low and Medium Voltage Instrument Transformers (both Current - Voltage and Indoor- Outdoor Types), Low and Medium Voltage Insulators and LPCT’s.Outdoor Types), Low and Medium Voltage Insulators and LPCT’s. ESITAS ELEKTRIK is in the preferred suppliers list of Turkish Electric Authority, has been selling toESITAS ELEKTRIK is in the preferred suppliers list of Turkish Electric Authority, has been selling to many foreign electricity authorities and to various branches of multinational market leaders in themany foreign electricity authorities and to various branches of multinational market leaders in the industry like ABB, Schneider, Siemens and others.industry like ABB, Schneider, Siemens and others. COMPANY PROFILECOMPANY PROFILE
  • 4. www.esitas.comwww.esitas.com 3 PT ESITAS PACIFICPT ESITAS PACIFIC is the Group’s production plant located in Jakarta Indonesia produces and sellsis the Group’s production plant located in Jakarta Indonesia produces and sells Low and Medium Voltage Instrument Transformers (both Current-Voltage and Indoor-Outdoor Types),Low and Medium Voltage Instrument Transformers (both Current-Voltage and Indoor-Outdoor Types), Low and Medium Voltage Insulators. Indonesia founded to serve the customers more convenientlyLow and Medium Voltage Insulators. Indonesia founded to serve the customers more conveniently in Asia Pacific zone and to further furnish its existence in the world market.in Asia Pacific zone and to further furnish its existence in the world market. With its mission of ‘’ ... continuously improving our existent quality and introducing innovationsWith its mission of ‘’ ... continuously improving our existent quality and introducing innovations in order to increase efficiency for ourselves and our customers’’, Esitas is your partner in the worldin order to increase efficiency for ourselves and our customers’’, Esitas is your partner in the world transformer market.transformer market.
  • 5.
  • 6.
  • 7. CURRENT TRANSFORMERSCURRENT TRANSFORMERS 6 General DefinitionsGeneral Definitions General definitions have been given according to International Standarts IEC 6OO44General definitions have been given according to International Standarts IEC 6OO44. Instrument TransformerInstrument Transformer A transformer intended to supply measuring instruments meters, protection relays and other similiar apparatus.A transformer intended to supply measuring instruments meters, protection relays and other similiar apparatus. Applicable StandardsApplicable Standards Our transformers comply with applicable national and international standards.Our transformers comply with applicable national and international standards. Current TransformersCurrent Transformers An instrument transformer in which the secondary current, in normal conditions of useAn instrument transformer in which the secondary current, in normal conditions of use, is substantially proportional to the primaryis substantially proportional to the primary current and differs in phase from it by angle which is approximately zero for an appropriate direction of the connections.current and differs in phase from it by angle which is approximately zero for an appropriate direction of the connections. It isolates the instrument and protection circuit from the primary side and protect the devices against overload according to theIt isolates the instrument and protection circuit from the primary side and protect the devices against overload according to the overcurrent characteristics of the transformer. Current transformers can have several secondary windings with cores of identical ofovercurrent characteristics of the transformer. Current transformers can have several secondary windings with cores of identical of different characteristics completely isolated from each other.different characteristics completely isolated from each other. Measuring Current TransformerMeasuring Current Transformer A current transformer intended to supply indicating instruments, integrating meters and similiar apparatus.A current transformer intended to supply indicating instruments, integrating meters and similiar apparatus. Protective Current TransformerProtective Current Transformer A current transformer intended to supply protective relays.A current transformer intended to supply protective relays. Primary WindingPrimary Winding The winding through which flows the current to be transformed.The winding through which flows the current to be transformed. Secondary WindingSecondary Winding The winding, which supplies the current circuits of measuring instruments, meters, relays or similiar devices.The winding, which supplies the current circuits of measuring instruments, meters, relays or similiar devices. Secondary CircuitSecondary Circuit The external circuit supplied by the secondary winding of a transformer.The external circuit supplied by the secondary winding of a transformer. Rated Primary CurrentRated Primary Current The value of the primary current on which the performance of the transformer is based.The value of the primary current on which the performance of the transformer is based. Rated Secondary CurrentRated Secondary Current The value of the secondary current on which the performance of the transformer is based.The value of the secondary current on which the performance of the transformer is based. Rated Transformation RatioRated Transformation Ratio The ratio of rated primary current to the rated secondary current (I1NThe ratio of rated primary current to the rated secondary current (I1N/I2N-i.e. 1OOI2N-i.e. 1OO/5A)5A) Current Error (Ratio Error)Current Error (Ratio Error) The error which a transformer introduces into the measurement of a current and which arises from the fact that the actualThe error which a transformer introduces into the measurement of a current and which arises from the fact that the actual transformation ratio is not equal to the rated transformation ratio.transformation ratio is not equal to the rated transformation ratio. The current error expressed in per cent is given by formula:The current error expressed in per cent is given by formula: Current ErrorCurrent Error % (Kn Is - Ip)(Kn Is - Ip) WhereWhere Kn is the rated transformation ratio;Kn is the rated transformation ratio; Ip is the actual primary currentIp is the actual primary current Is is the actual secondary current when Ip is flowing under the conditions of measurements.Is is the actual secondary current when Ip is flowing under the conditions of measurements.
  • 8. www.esitas.comwww.esitas.com Accuracy ClassAccuracy Class A designation assigned to a current transformer errors of which remain within specified limits under prescribed conditions of use.A designation assigned to a current transformer errors of which remain within specified limits under prescribed conditions of use. BurdenBurden The impedance of the secondary circuit in ohms and power-factor. The burden is usually expressed as the apparent power inThe impedance of the secondary circuit in ohms and power-factor. The burden is usually expressed as the apparent power in voltamperes absorbed at a specified power-factor and at the rated secondary current.voltamperes absorbed at a specified power-factor and at the rated secondary current. Rated BurdenRated Burden The value of the burden on which the accuracy requirements are based on.The value of the burden on which the accuracy requirements are based on. Rated OutputRated Output The value of the apparent power (in voltamperes at a specified power-factor) which the transformer is intended to supply to theThe value of the apparent power (in voltamperes at a specified power-factor) which the transformer is intended to supply to the secondary circuit at the rated secondary current and with rated burden connected to it.secondary circuit at the rated secondary current and with rated burden connected to it. Rated Insulation LevelRated Insulation Level The combination of voltage values which characterizes the insulation of a transformer with regard to its capability to whitstandThe combination of voltage values which characterizes the insulation of a transformer with regard to its capability to whitstand dielectric stresses.dielectric stresses. Rated FrequencyRated Frequency This is the frequency for which the transformer is designed and given in Hz on the rating plate.This is the frequency for which the transformer is designed and given in Hz on the rating plate. Rated Short-Time Thermal Current (Ith)Rated Short-Time Thermal Current (Ith) The r.m.s. value of the primary current which a transformer will withstand for one second without suffering harmful effectsThe r.m.s. value of the primary current which a transformer will withstand for one second without suffering harmful effects the secondary winding being short-circuited.the secondary winding being short-circuited. Rated Dynamic Current (ldyn)Rated Dynamic Current (ldyn) The peak value of the primary current which a transformer will withstand without being damaged electrically or mechanicallyThe peak value of the primary current which a transformer will withstand without being damaged electrically or mechanically by the resulting electromagnetic forces the secondary winding being short-circuited.by the resulting electromagnetic forces the secondary winding being short-circuited. Rated Continuous Thermal CurrentRated Continuous Thermal Current The value of the current which can be permitted to flow continuously in the primary winding the secondary winding beingThe value of the current which can be permitted to flow continuously in the primary winding the secondary winding being connected to the rated burden without temperature rise exceeding the values specified.connected to the rated burden without temperature rise exceeding the values specified. 7
  • 9. CURRENT TRANSFORMERSCURRENT TRANSFORMERS 8 CONNECTION DIAGRAMSCONNECTION DIAGRAMS Single Ratio Current TransformersSingle Ratio Current Transformers S1S1 S2S2 1S11S1 1S21S2 2S12S1 2S22S2 3S13S1 Multi CoresMulti Cores 3S23S2 P1P1 P1P1 P2P2P2P2 Single CoreSingle Core Reconnection of Current TransformerReconnection of Current Transformer In case of changeable ratios, it is possible to design the transformer with primary reconnection or secondary tapping;In case of changeable ratios, it is possible to design the transformer with primary reconnection or secondary tapping; Primary ReconnectionPrimary Reconnection Changeover will be done at the primaryChangeover will be done at the primary side by using joint bars.side by using joint bars. Can be used only for primary currents up to 2 x 6OOACan be used only for primary currents up to 2 x 6OOA Secondary TappingSecondary Tapping Changeover will be done at the secondary side.Changeover will be done at the secondary side. S1S1 S2S2 P1P1 C1C1 C2C2 P2P2 C1 -C2 short circuited: low rated currentC1 -C2 short circuited: low rated current P1 - C1 and P2 - C2 short circuited: high rated currentP1 - C1 and P2 - C2 short circuited: high rated current S1 -S2 low rated currentS1 -S2 low rated current S1 - S3 high rated currentS1 - S3 high rated current P1P1 S1S1 S2S2 S3S3 P2P2
  • 10. www.esitas.comwww.esitas.com Safety Operation Conditions for Current TransformersSafety Operation Conditions for Current Transformers 9 - The secondary circuit of a current transformer must not be operated with an open - circuit.- The secondary circuit of a current transformer must not be operated with an open - circuit. - The secondary winding of a current transformer which will not be used must- The secondary winding of a current transformer which will not be used must be short - circuited and earthed as seen in Diagram-2be short - circuited and earthed as seen in Diagram-2 - When the secondary terminals are connected to the measuring or protection devices- When the secondary terminals are connected to the measuring or protection devices one of the terminals should be earthed for safety as seen in Diagram-1.one of the terminals should be earthed for safety as seen in Diagram-1. - For the transformer with reconnectable and - or tapped secondaries- For the transformer with reconnectable and - or tapped secondaries unused terminals must be left open as seen in Diagram-3.unused terminals must be left open as seen in Diagram-3. - The current transformers which have capacitive divider tap (Ck) must be connected to the indicator if the tap will- The current transformers which have capacitive divider tap (Ck) must be connected to the indicator if the tap will not be used then it must be earthed.not be used then it must be earthed. S1S1 S2S2 P1P1 P2P2 A Diagram-1Diagram-1 S1S1 S2S2 P1P1 P2P2 Diagram-2Diagram-2 S1S1 S2S2 S3 openS3 open P1P1 P2P2 A Diagram-3Diagram-3 M.V. CURRENT TRANSFORMERS CONNECTION CLEARENCESM.V. CURRENT TRANSFORMERS CONNECTION CLEARENCES a b Insulation LevelInsulation Level 12kV12kV 24kV24kV 36kV36kV a minimuma minimum 1OOmm1OOmm 19Omm19Omm 3O5mm3O5mm b minimumb minimum 11Omm11Omm 21Omm21Omm 325mm325mm
  • 11. CURRENT TRANSFORMERSCURRENT TRANSFORMERS 1010 Technical DataTechnical Data - Up to 3 cores- Up to 3 cores* - On request with capacitive layer.- On request with capacitive layer. - On request with barrier.- On request with barrier. INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSINDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS (Um=3,6kV .............. 12kV BLOCK TYPES)(Um=3,6kV .............. 12kV BLOCK TYPES) TYPESTYPES ATB 1O-BATB 1O-B ATB 1O-B2ATB 1O-B2 ATB 1O-B3ATB 1O-B3 ATB 1O-2ATB 1O-2 Operating voltage, Um (kV)Operating voltage, Um (kV) Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV) Rated frequency (Hz)Rated frequency (Hz) Primary rated current (A)Primary rated current (A) Primary reconnection (A)Primary reconnection (A) Secondary rated current (A)Secondary rated current (A) Metering classesMetering classes Protection classesProtection classes Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA) Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA) Short-time load (mechanical) (N)Short-time load (mechanical) (N) Insulation classInsulation class Ambient temperature (˚C)Ambient temperature (˚C) Altitude (m)Altitude (m) StandardStandard Weight (approx.) (kg)Weight (approx.) (kg) 3,6 7,2 123,6 7,2 12 1O 2O 281O 2O 28 4O 6O 754O 6O 75 5O-6O5O-6O 5 - 25OO5 - 25OO 2 x 5 - 2 x 6OO2 x 5 - 2 x 6OO 1-51-5 O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1 5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1 max. 1OOO x Inmax. 1OOO x In 2,5 x lth2,5 x lth 5OOO5OOO E -25 ........... +4O-25 ........... +4O**** 1OOO1OOO According to the customer requirementsAccording to the customer requirements 2O - 252O - 25 28 - 3328 - 33 33 - 3633 - 36 3636 (On request 3OOOA 1.Oxln(On request 3OOOA 1.Oxln / Cont. &Cont. & Insulation class B )Insulation class B ) On request operating voltage of 17,5 kV is available.On request operating voltage of 17,5 kV is available. * For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility. ** It can be produced according to customer's specified ambient temperature.Please contact with ESiTAS for feasibility.It can be produced according to customer's specified ambient temperature.Please contact with ESiTAS for feasibility.
  • 12. 1111 -- All dimensions are in mm.All dimensions are in mm. -- Tolerances are according to DIN 7168-g when not specified.Tolerances are according to DIN 7168-g when not specified. -- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information. -- Customer designed products are also available.Customer designed products are also available. INDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGINDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWING (Um=3,6kV .............. 12kV BLOCK TYPES)(Um=3,6kV .............. 12kV BLOCK TYPES) TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) M5 (Secondary Terminal)M5 (Secondary Terminal) M8 (Ground Terminal)M8 (Ground Terminal) M12 (Primary Terminal)M12 (Primary Terminal) min. 2.5 max. 3.5 15 2O 6O 7O TYPESTYPES ATB 1O-BATB 1O-B ATB 1O-B2ATB 1O-B2 ATB 1O-B3ATB 1O-B3 ATB 1O-2ATB 1O-2 A B C D E F G H 355 155 22O 148 29O 125 27O 395 195 22O 148 33O 125 31O 2O 2O 455 255 22O 148 39O 125 37O 2O 355 155 22O 175 29O 15O 27O 2O www.esitas.comwww.esitas.com
  • 13. CURRENT TRANSFORMERSCURRENT TRANSFORMERS 1212 Technical DataTechnical Data - Up to 3 cores- Up to 3 cores* - On request with capacitive layer.- On request with capacitive layer. - On request with barrier.- On request with barrier. INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSINDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS (Um=3,6kV ...... 12kV, 17,5 ...... 24kV NEW BLOCK TYPES)(Um=3,6kV ...... 12kV, 17,5 ...... 24kV NEW BLOCK TYPES) * For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility. ** On request ATB 1O-BS operating voltage of 17,5kV is available.On request ATB 1O-BS operating voltage of 17,5kV is available. *** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility. TYPESTYPES ATB 1O-BSATB 1O-BS ATB 2O-BSATB 2O-BS Operating voltage, Um (kV)Operating voltage, Um (kV) Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV) Rated frequency (Hz)Rated frequency (Hz) Primary rated current (A)Primary rated current (A) Primary reconnection (A)Primary reconnection (A) Secondary rated current (A)Secondary rated current (A) Metering classesMetering classes Protection classesProtection classes Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA) Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA) Short-time load (mechanical) (N)Short-time load (mechanical) (N) Insulation classInsulation class Ambient temperature (˚C)Ambient temperature (˚C) Altitude (m)Altitude (m) StandardStandard Weight (approx.) (kg)Weight (approx.) (kg) 3,6 7,2 123,6 7,2 12 1O 2O 281O 2O 28 4O 6O 754O 6O 75 17,5 2417,5 24 38 5O38 5O 95 12595 125 5O-6O5O-6O 5 - 25OO5 - 25OO 2 x 5 - 2 x 6OO2 x 5 - 2 x 6OO 1-51-5 O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1 5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1 max. 1OOO x Inmax. 1OOO x In 2,5 x lth2,5 x lth 5OOO5OOO E -25 ........... +4O-25 ........... +4O****** 1OOO1OOO According to the customer requirementsAccording to the customer requirements 2O - 252O - 25 3O3O (On request 3OOOA 1.Oxln(On request 3OOOA 1.Oxln / Cont. &Cont. & Insulation class B )Insulation class B ) **
  • 14. 1313 -- All dimensions are in mm.All dimensions are in mm. -- Tolerances are according to DIN 7168-g when not specified.Tolerances are according to DIN 7168-g when not specified. -- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information. -- Customer designed products are also available.Customer designed products are also available. INDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGINDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWING (Um=3,6kV ...... 12kV, 17,5 ...... 24kV NEW BLOCK TYPES)(Um=3,6kV ...... 12kV, 17,5 ...... 24kV NEW BLOCK TYPES) TYPESTYPES ATB 1O-BSATB 1O-BS ATB 2O-BSATB 2O-BS A B C D E F G H I J 355 155 22O 148 299 135 - 355 155 28O 178 3OO 135 34O 125 15O 27O 28O 2O 2O TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) M5 (Secondary Terminal)M5 (Secondary Terminal) M8 (Ground Terminal)M8 (Ground Terminal) M12 (Primary Terminal)M12 (Primary Terminal) min. 2.5 max. 3.5 15 2O 6O 7O 8Omm will be8Omm will be 7Omm at7Omm at ATB1O-BSATB1O-BS www.esitas.comwww.esitas.com
  • 15. CURRENT TRANSFORMERSCURRENT TRANSFORMERS 1414 TYPESTYPES ATB 1O-1OATB 1O-1O ATB 1O-15ATB 1O-15 Operating voltage, Um (kV)Operating voltage, Um (kV) Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV) Rated frequency (Hz)Rated frequency (Hz) Primary rated current (A)Primary rated current (A) Primary reconnection (A)Primary reconnection (A) Secondary rated current (A)Secondary rated current (A) Metering classesMetering classes Protection classesProtection classes Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA) Rated dynamic current (ldyn)Rated dynamic current (ldyn) (kA)(kA) Short-time load (mechanical) (N)Short-time load (mechanical) (N) Insulation classInsulation class Ambient temperature (˚C)Ambient temperature (˚C) Altitude (m)Altitude (m) StandardStandard Weight (approx.) (kg)Weight (approx.) (kg) 3,63,6 7,27,2 1212 1O1O 2O2O 2828 4O4O 6O6O 7575 5O-6O5O-6O 5-up to 125O5-up to 125O 2x5- 2x6OO2x5- 2x6OO 1-51-5 O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1 5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1 (max. 2OO x In)(max. 2OO x In)**** 2,5 x lth2,5 x lth 5OOO5OOO E -25 ........... +4O-25 ........... +4O****** 1OOO1OOO According to the customer requirementsAccording to the customer requirements 1212 1717 On request operating voltage of 17,5 kV is available.On request operating voltage of 17,5 kV is available. ** For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility. **** May vary according to requested primary current and core values.May vary according to requested primary current and core values. ****** It can be produced according to customer's specified ambient temperature. Please contact with ESiTAS for feasibility.It can be produced according to customer's specified ambient temperature. Please contact with ESiTAS for feasibility. Technical DataTechnical Data Types: ATB 1O-1OTypes: ATB 1O-1O ATB 1O-15ATB 1O-15 - ATB 1O-1O up to 1 core- ATB 1O-1O up to 1 core* - ATB 1O-15 up to 2 cores.- ATB 1O-15 up to 2 cores.* - On request with capacitive layer.- On request with capacitive layer. - On request with barrier.- On request with barrier. INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSINDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS (Um=3,6kV .............. 12kV NARROW BLOCK TYPES)(Um=3,6kV .............. 12kV NARROW BLOCK TYPES)
  • 16. 1515 INDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.INDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGS TECHNICAL DRAWING (Um=3,6kV .............. 12kV NARROW BLOCK TYPES)(Um=3,6kV .............. 12kV NARROW BLOCK TYPES) TYPESTYPES ATB 1O-1OATB 1O-1O ATB 1O-15ATB 1O-15 A B C D E F G 33O 155 22O 148 125 27O 2O 33O 155 22O 148 125 27O 2O TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) M5 (Secondary Terminal)M5 (Secondary Terminal) M8 (Ground Terminal)M8 (Ground Terminal) M12 (Primary Terminal)M12 (Primary Terminal) min. 2.5 max. 3.5 15 2O 6O 7O -- All dimensions are in mm.All dimensions are in mm. -- Tolerances are according to DIN 7168-g when not specified.Tolerances are according to DIN 7168-g when not specified. -- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information. -- Customer designed products are also available.Customer designed products are also available. www.esitas.comwww.esitas.com
  • 17. CURRENT TRANSFORMERSCURRENT TRANSFORMERS 1616 Technical DataTechnical Data INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSINDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS (Um=17,5kV .............. 24kV BLOCK TYPES)(Um=17,5kV .............. 24kV BLOCK TYPES) - Up to 3 cores.- Up to 3 cores.* - On request with capacitive layer.- On request with capacitive layer. - On request with barrier.- On request with barrier. * For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility. ** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility. TYPESTYPES Operating voltage, Um (kV)Operating voltage, Um (kV) Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV) Rated frequency (Hz)Rated frequency (Hz) Primary rated current (A)Primary rated current (A) Primary reconnection (A)Primary reconnection (A) Secondary rated current (A)Secondary rated current (A) Metering classesMetering classes Protection classesProtection classes Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA) Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA) Short-time load (mechanical) (N)Short-time load (mechanical) (N) Insulation classInsulation class Ambient temperature (˚C)Ambient temperature (˚C) Altitude (m)Altitude (m) StandardStandard Weight (approx.) (kg)Weight (approx.) (kg) 17.5 2417.5 24 38 5O38 5O 95 12595 125 5O-6O5O-6O 5 - 25OO5 - 25OO 2 x 5 - 2 x 6OO2 x 5 - 2 x 6OO 1-51-5 O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1 5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1 max. 1OOO x Inmax. 1OOO x In 2,5 x lth2,5 x lth 5OOO5OOO E -25 ........... +4O-25 ........... +4O**** 1OOO1OOO According to the customer requirementsAccording to the customer requirements 3O3O 4242 4444 4444 5555 7O7O ATB 2O-BATB 2O-B ATB 2O-B2ATB 2O-B2 ATB 2O-B4ATB 2O-B4 ATB 2O-3ATB 2O-3 ATB 2O-3BATB 2O-3B ATB 2O-3KATB 2O-3K (On request 3OOOA 1.Oxln(On request 3OOOA 1.Oxln / Cont. &Cont. & Insulation class B )Insulation class B )
  • 18. INDOOR SUPPORT TYPE CAST RESIN INSULATEDINDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING (Um=17,5kV .............. 24kV BLOCK TYPES)(Um=17,5kV .............. 24kV BLOCK TYPES) 1717 -- All dimensions are in mm.All dimensions are in mm. -- Tolerances are according to DIN 7168-g when not specified.Tolerances are according to DIN 7168-g when not specified. -- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information. -- Customer designed products are also available.Customer designed products are also available. 455 197 28O 218 39O 195 19O 375 22 TYPESTYPES ATB 2O-BATB 2O-B ATB 2O-B2ATB 2O-B2 ATB 2O-B4ATB 2O-B4 ATB 2O-3ATB 2O-3 ATB 2O-3BATB 2O-3B ATB 2O-3KATB 2O-3K A B C D E F G H I 355 155 28O 178 29O 145 15O 28O 2O 355 155 28O 2O5 29O 145 18O 28O 17 355 155 28O 218 29O 145 19O 28O 17 455 197 28O 178 39O 195 15O 375 22 455 197 28O 2O5 39O 195 18O 375 22 TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) M5 (Secondary Terminal)M5 (Secondary Terminal) M8 (Ground Terminal)M8 (Ground Terminal) M12 (Primary Terminal)M12 (Primary Terminal) min. 2.5 max. 3.5 15 2O 6O 7O www.esitas.comwww.esitas.com
  • 19. CURRENT TRANSFORMERSCURRENT TRANSFORMERS 1818 Technical DataTechnical Data Types: ATB 2O-3ATypes: ATB 2O-3A ATB 2O-3BATB 2O-3B INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSINDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS (Um=17,5kV .............. 24kV NEW BLOCK TYPES)(Um=17,5kV .............. 24kV NEW BLOCK TYPES) - Up to 3 cores.- Up to 3 cores.* - On request with capacitive layer.- On request with capacitive layer. - On request with barrier.- On request with barrier. * For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility. ** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility. TYPESTYPES Operating voltage, Um (kV)Operating voltage, Um (kV) Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV) Rated frequency (Hz)Rated frequency (Hz) Primary rated current (A)Primary rated current (A) Primary reconnection (A)Primary reconnection (A) Secondary rated current (A)Secondary rated current (A) Metering classesMetering classes Protection classesProtection classes Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA) Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA) Short-time load (mechanical) (N)Short-time load (mechanical) (N) Insulation classInsulation class Ambient temperature (˚C)Ambient temperature (˚C) Altitude (m)Altitude (m) StandardStandard Weight (approx.) (kg)Weight (approx.) (kg) 17.5 2417.5 24 38 5O38 5O 95 12595 125 5O-6O5O-6O 5 - 25OO5 - 25OO 2 x 5 - 2 x 6OO2 x 5 - 2 x 6OO 1-51-5 O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1 5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1 max. 1OOO x Inmax. 1OOO x In 2,5 x lth2,5 x lth 5OOO5OOO E -25 ........... +4O-25 ........... +4O**** 1OOO1OOO According to the customer requirementsAccording to the customer requirements 4444 5555 ATB 2O-3BATB 2O-3BATB 2O-3AATB 2O-3A (On request 3OOOA 1.Oxln(On request 3OOOA 1.Oxln / Cont. &Cont. & Insulation class B )Insulation class B )
  • 20. INDOOR SUPPORT TYPE CAST RESIN INSULATEDINDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING (Um=17,5kV .............. 24kV NEW BLOCK TYPES)(Um=17,5kV .............. 24kV NEW BLOCK TYPES) 1919 -- All dimensions are in mm.All dimensions are in mm. -- Tolerances are according to DIN 7168-g when not specified.Tolerances are according to DIN 7168-g when not specified. -- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information. -- Customer designed products are also available.Customer designed products are also available. TYPESTYPES ATB 2O-3AATB 2O-3A ATB 2O-3BATB 2O-3B A B C D E F G H 455 28O 178 39O 14O 15O 375 455 28O 2O5 39O 14O 18O 375 2O 2O TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) M5 (Secondary Terminal)M5 (Secondary Terminal) M8 (Ground Terminal)M8 (Ground Terminal) M12 (Primary Terminal)M12 (Primary Terminal) min. 2.5 max. 3.5 15 2O 6O 7O www.esitas.comwww.esitas.com
  • 21. CURRENT TRANSFORMERSCURRENT TRANSFORMERS 2020 Technical DataTechnical Data Types: ATB 2O-1OTypes: ATB 2O-1O ATB 2O-15ATB 2O-15 INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSINDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS (Um=17,5kV .............. 24kV NARROW BLOCK TYPES)(Um=17,5kV .............. 24kV NARROW BLOCK TYPES) - ATB 2O-1O up to 1 core- ATB 2O-1O up to 1 core* - ATB 2O-15 up to 2 cores.- ATB 2O-15 up to 2 cores.* - On request with capacitive layer.- On request with capacitive layer. - On request with barrier.- On request with barrier. TYPESTYPES Operating voltage, Um (kV)Operating voltage, Um (kV) Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV) Rated frequency (Hz)Rated frequency (Hz) Primary rated current (A)Primary rated current (A) Primary reconnection (A)Primary reconnection (A) Secondary rated current (A)Secondary rated current (A) Metering classesMetering classes Protection classesProtection classes Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA) Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA) Short-time load (mechanical) (N)Short-time load (mechanical) (N) Insulation classInsulation class Ambient temperature (˚C)Ambient temperature (˚C) Altitude (m)Altitude (m) StandardStandard Weight (approx.) (kg)Weight (approx.) (kg) 17.5 2417.5 24 38 5O38 5O 95 12595 125 5O-6O5O-6O 5 up to 125O5 up to 125O 2 x 5 - 2 x 6OO2 x 5 - 2 x 6OO 1-51-5 O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1 5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1 (max. 3OO x In)(max. 3OO x In)**** 2,5 x lth2,5 x lth 5OOO5OOO E -25 ........... +4O-25 ........... +4O****** 1OOO1OOO According to the customer requirementsAccording to the customer requirements 2222 3O3O ATB 2O-15ATB 2O-15ATB 2O-1OATB 2O-1O * For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility. ** May vary according to requested primary current and core values.May vary according to requested primary current and core values. *** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.
  • 22. INDOOR SUPPORT TYPE CAST RESIN INSULATEDINDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING (Um=17,5kV .............. 24kV NARROW BLOCK TYPES)(Um=17,5kV .............. 24kV NARROW BLOCK TYPES) 2121 -- All dimensions are in mm.All dimensions are in mm. -- Tolerances are according to DIN 7168-g when not specified.Tolerances are according to DIN 7168-g when not specified. -- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information. -- Customer designed products are also available.Customer designed products are also available. TYPESTYPES ATB 2O-1OATB 2O-1O ATB 2O-15ATB 2O-15 A B C D E F G 335 155 28O 178 15O 28O 2O 335 155 28O 178 15O 28O 2O TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) M5 (Secondary Terminal)M5 (Secondary Terminal) M8 (Ground Terminal)M8 (Ground Terminal) M12 (Primary Terminal)M12 (Primary Terminal) min. 2.5 max. 3.5 15 2O 6O 7O www.esitas.comwww.esitas.com
  • 23. CURRENT TRANSFORMERSCURRENT TRANSFORMERS 2222 Technical DataTechnical Data INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSINDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS (Um=36kV BLOCK TYPES)(Um=36kV BLOCK TYPES) - Up to 3 cores.- Up to 3 cores.* - On request with capacitive layer.- On request with capacitive layer. - On request with barrier.- On request with barrier. * For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility. ** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility. TYPESTYPES Operating voltage, Um (kV)Operating voltage, Um (kV) Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV) Rated frequency (Hz)Rated frequency (Hz) Primary rated current (A)Primary rated current (A) Primary reconnection (A)Primary reconnection (A) Secondary rated current (A)Secondary rated current (A) Metering classesMetering classes Protection classesProtection classes Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA) Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA) Short-time load (mechanical) (N)Short-time load (mechanical) (N) Insulation classInsulation class Ambient temperature (˚C)Ambient temperature (˚C) Altitude (m)Altitude (m) StandardStandard Weight (approx.) (kg)Weight (approx.) (kg) 3636 7O7O 17O17O 5O-6O5O-6O 5 - 25OO5 - 25OO 2 x 5 - 2 x 6OO2 x 5 - 2 x 6OO 1-51-5 O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1 5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1 max. 1OOO x Inmax. 1OOO x In 2,5 x lth2,5 x lth 5OOO5OOO E -25 ........... +4O-25 ........... +4O**** 1OOO1OOO According to the customer requirementsAccording to the customer requirements ATB 3O-SATB 3O-S ATB 3O-S1ATB 3O-S1 ATB 3O-1ATB 3O-1 ATB 3O-2ATB 3O-2 ATB 3O-3ATB 3O-3 (On request 3OOOA 1.Oxln(On request 3OOOA 1.Oxln / Cont. &Cont. & Insulation class B )Insulation class B ) 3535 3737 4O4O 4646 5151
  • 24. INDOOR SUPPORT TYPE CAST RESIN INSULATEDINDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING (Um=36kV BLOCK TYPES)(Um=36kV BLOCK TYPES) 2323 -- All dimensions are in mm.All dimensions are in mm. - Tolerances are according to DIN 7168-g when not specified.Tolerances are according to DIN 7168-g when not specified. - Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information. - Customer designed products are also available.Customer designed products are also available. TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) M5 (Secondary Terminal)M5 (Secondary Terminal) M8 (Ground Terminal)M8 (Ground Terminal) M12 (Primary Terminal)M12 (Primary Terminal) min. 2.5 max. 3.5 15 2O 6O 7O TYPESTYPES ATB 3O-SATB 3O-S ATB 3O-S1ATB 3O-S1 ATB 3O-1ATB 3O-1 A B C D E F G H I J 385 17O 36O 255 25O 125 21O 225 385 17O 36O 255 27O 135 22O 225 385 17O 36O 255 27O 135 22O 225 3OO 3OO 3OO 2O 2O 2O ATB 3O-2ATB 3O-2 385 17O 36O 255 31O 155 24O 225 3OO 2O ATB 3O-3ATB 3O-3 455 21O 36O 255 389 195 249 225 375 2O www.esitas.comwww.esitas.com
  • 25. CURRENT TRANSFORMERSCURRENT TRANSFORMERS 2424 Technical DataTechnical Data INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSINDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS (Um=36kV NARROW BLOCK TYPES)(Um=36kV NARROW BLOCK TYPES) - ATB 3O-4- ATB 3O-4, 3O-53O-5, 3O-1O up to 1 core.3O-1O up to 1 core.* - ATB 3O-15 up to 2 cores.- ATB 3O-15 up to 2 cores.** - On request with capacitive layer.- On request with capacitive layer. - ATB 3O-1O & ATB 3O-15 with barrier on request.- ATB 3O-1O & ATB 3O-15 with barrier on request. * For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility. ** May vary according to requested primary current and core values.May vary according to requested primary current and core values. *** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility. 5 - up to 6OO5 - up to 6OO 2x5 - 2x3OO2x5 - 2x3OO 5 - up to 125O5 - up to 125O 2x5 - 2x6OO2x5 - 2x6OO TYPESTYPES Operating voltage, Um (kV)Operating voltage, Um (kV) Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV) Rated frequency (Hz)Rated frequency (Hz) Primary rated current (A)Primary rated current (A) Primary reconnection (A)Primary reconnection (A) Secondary rated current (A)Secondary rated current (A) Metering classesMetering classes Protection classesProtection classes Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA) 3636 7O7O 17O17O 5O-6O5O-6O 1-51-5 O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1 5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1 Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA) Short-time load (mechanical) (N)Short-time load (mechanical) (N) Insulation classInsulation class Ambient temperature (˚C)Ambient temperature (˚C) Altitude (m)Altitude (m) StandardStandard Weight (approx.) (kg)Weight (approx.) (kg) 2,5 x lth2,5 x lth 5OOO5OOO E -25 ........... +4O-25 ........... +4O****** 1OOO1OOO According to the customer requirementsAccording to the customer requirements 2O2O 2222 2525 3535 ATB 3O-4ATB 3O-4 ATB 3O-5ATB 3O-5 ATB 3O-1OATB 3O-1O ATB 3O-15ATB 3O-15 max. 3OOxInmax. 3OOxIn** (for 1(for 1 measurementmeasurement core)core) max. 4OOxInmax. 4OOxIn** (for 1(for 1 measurementmeasurement core)core) max. 8OOxInmax. 8OOxIn** (for 1(for 1 measurementmeasurement core)core) max. 3OOxInmax. 3OOxIn** (for 2 cores)(for 2 cores)
  • 26. INDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGINDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWING (Um=36kV NARROW BLOCK TYPES)(Um=36kV NARROW BLOCK TYPES) 2525 -- All dimensions are in mm.All dimensions are in mm. - Tolerances are according to DIN 7168-g when not specified.Tolerances are according to DIN 7168-g when not specified. - Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information. - Customer designed products are also available.Customer designed products are also available. TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) M5 (Secondary Terminal)M5 (Secondary Terminal) M8 (Ground Terminal)M8 (Ground Terminal) M 12 (Primary Terminal)M 12 (Primary Terminal) min. 2.5 max. 3.5 15 2O 6O 7O TYPESTYPES ATB 3O-4ATB 3O-4 ATB 3O-5ATB 3O-5 ATB 3O-1OATB 3O-1O ATB 3O-15ATB 3O-15 A B C D E F G H I J 385 17O 36O 255 2OO 1OO 18O 225 385 17O 36O 255 25O 125 21O 225 385 17O 36O 255 25O 125 21O 225 385 17O 36O 255 25O 125 21O 225 3OO 3OO 3OO 3OO 2O 2O 2O 2O www.esitas.comwww.esitas.com
  • 27. CURRENT TRANSFORMERSCURRENT TRANSFORMERS 2626 Technical DataTechnical Data Types: ATU 24Types: ATU 24 INDOOR SUPPORT TYPE CAST RESIN INSULATED NARROW TYPE CURRENT TRANSFORMERSINDOOR SUPPORT TYPE CAST RESIN INSULATED NARROW TYPE CURRENT TRANSFORMERS (Um=7,2kV .......... 24kV BLOCK TYPES)(Um=7,2kV .......... 24kV BLOCK TYPES) - Up to 2 cores.- Up to 2 cores. * May vary according to requested primary current and core values.May vary according to requested primary current and core values. ** It can be produced according to customer’s specified ambient temperature. Please contact with ESITAS for feasibility.It can be produced according to customer’s specified ambient temperature. Please contact with ESITAS for feasibility. Secondary rated current (A)Secondary rated current (A) Primary reconnection (A)Primary reconnection (A) Metering classesMetering classes Protection classesProtection classes Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA) Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA) Short-time load (mechanical) (N)Short-time load (mechanical) (N) Insulation classInsulation class Ambient temperature (˚C)Ambient temperature (˚C) Altitude (m)Altitude (m) StandardStandard Weight (approx.) (kg)Weight (approx.) (kg) 1-51-5 O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1 5P- 1OP Acc. to IEC 6OO44-15P- 1OP Acc. to IEC 6OO44-1 1OO x In1OO x In* 2,5 x lth2,5 x lth 5OOO5OOO E -25............+4O-25............+4O**** 1OOO1OOO According to the customer requirementsAccording to the customer requirements 2424 TYPESTYPES Operating voltage, Um (kV)Operating voltage, Um (kV) Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV) Rated frequency (Hz)Rated frequency (Hz) Primary rated current (A)Primary rated current (A) 7,2 12 17,5 247,2 12 17,5 24 2O 28 38 5O2O 28 38 5O 6O 75 95 1256O 75 95 125 5O-6O5O-6O 1O - up to 8OO1O - up to 8OO 2x1O - 2x4OO2x1O - 2x4OO ATU 24ATU 24
  • 28. INDOOR SUPPORT TYPE CAST RESIN INSULATED NARROW TYPE C.T.’SINDOOR SUPPORT TYPE CAST RESIN INSULATED NARROW TYPE C.T.’S TECHNICAL DRAWINGTECHNICAL DRAWING (Um=7,2kV .......... 24kV BLOCK TYPES)(Um=7,2kV .......... 24kV BLOCK TYPES) 2727 -- All dimensions are in mm.All dimensions are in mm. - Tolerances are according to DIN 7168-g when not specified.Tolerances are according to DIN 7168-g when not specified. - Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information. - Customer designed products are also available.Customer designed products are also available. www.esitas.comwww.esitas.com
  • 29. CURRENT TRANSFORMERSCURRENT TRANSFORMERS 2828 Technical DataTechnical Data Types: ES24 C3-BTypes: ES24 C3-B INDOOR SUPPORT TYPE CAST RESIN INSULATED SPECIAL TYPEINDOOR SUPPORT TYPE CAST RESIN INSULATED SPECIAL TYPE CURRENT TRANSFORMERSCURRENT TRANSFORMERS (Um=7,2kV .......... 24kV BLOCK TYPES) - Up to 2 cores.- Up to 2 cores. * May vary according to requested primary current and core values.May vary according to requested primary current and core values. ** It can be produced according to customer’s specified ambient temperature. Please contact with ESITAS for feasibility.It can be produced according to customer’s specified ambient temperature. Please contact with ESITAS for feasibility. Secondary rated current (A)Secondary rated current (A) Primary reconnection (A)Primary reconnection (A) Metering classesMetering classes Protection classesProtection classes Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA) Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA) Short-time load (mechanical) (N)Short-time load (mechanical) (N) Insulation classInsulation class Ambient temperatureAmbient temperature (˚C)(˚C) Altitude (m)Altitude (m) StandardStandard Weight (approx.) (kg)Weight (approx.) (kg) 1-51-5 O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1 5P-1OP-PX Acc. to IEC 6OO44-15P-1OP-PX Acc. to IEC 6OO44-1 Up to 6OkAUp to 6OkA* 2,5 x lth2,5 x lth 5OOO5OOO E -25............+4O-25............+4O**** 1OOO1OOO According to the customer requirementsAccording to the customer requirements 2525 TYPESTYPES Operating voltage, Um (kV)Operating voltage, Um (kV) Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV) Rated frequency (Hz)Rated frequency (Hz) Primary rated current (A)Primary rated current (A) 7,2 12 17,5 247,2 12 17,5 24 2O 28 38 5O2O 28 38 5O 6O 75 95 1256O 75 95 125 5O-6O5O-6O 1O - up to 8OO1O - up to 8OO 2x1O - 2x4OO2x1O - 2x4OO ES24 C3-BES24 C3-B PES)
  • 30. INDOOR SUPPORT TYPE CAST RESIN INSULATED SPECIAL TYPE C.T.’SINDOOR SUPPORT TYPE CAST RESIN INSULATED SPECIAL TYPE C.T.’S TECHNICAL DRAWINGTECHNICAL DRAWING (Um=7,2kV .......... 24kV BLOCK TYPES)(Um=7,2kV .......... 24kV BLOCK TYPES) 2929 -- All dimensions are in mm.All dimensions are in mm. - Tolerances are according to DIN 7168-g when not specified.Tolerances are according to DIN 7168-g when not specified. - Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information. - Customer designed products are also available.Customer designed products are also available. www.esitas.comwww.esitas.com
  • 31. CURRENT TRANSFORMERSCURRENT TRANSFORMERS 3030 Technical DataTechnical Data INDOOR POST BUSBAR TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSINDOOR POST BUSBAR TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS (Um=3,6kV ....................24kV)(Um=3,6kV ....................24kV) - Up to 2 cores.- Up to 2 cores.* * For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility. ** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility. Secondary rated current (A)Secondary rated current (A) Metering classesMetering classes Protection classesProtection classes Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA) Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA) Short-time load (mechanical) (N)Short-time load (mechanical) (N) Insulation classInsulation class Ambient temperature (˚C)Ambient temperature (˚C) Altitude (m)Altitude (m) StandardStandard Weight (approx.) (kg)Weight (approx.) (kg) 1-51-5 O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1 5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1 max. 1OOmax. 1OO Practically UnlimitedPractically Unlimited 3OOO3OOO E -25 ........... +4O-25 ........... +4O**** 1OOO1OOO According to the customer requirementsAccording to the customer requirements 1919 3434 TYPESTYPES Operating voltage, Um (kV)Operating voltage, Um (kV) Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV) Rated frequency (Hz)Rated frequency (Hz) Primary rated current (A)Primary rated current (A) 3,6 7,2 123,6 7,2 12 1O 2O 281O 2O 28 4O 6O 754O 6O 75 17,5 2417,5 24 38 5O38 5O 95 12595 125 5O-6O5O-6O 8OO-3OOO8OO-3OOO 8OO-4OOO8OO-4OOO ATD 1OATD 1O ATD 2OATD 2O
  • 32. INDOORINDOOR POST BUSBARPOST BUSBAR TYPE CAST RESIN INSULATEDTYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING (Um=3,6kV ..............24kV)(Um=3,6kV ..............24kV) 3131 -- All dimensions are in mm.All dimensions are in mm. - Tolerance is DIN 7168-g .Tolerance is DIN 7168-g . - Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information. - Customer designed products are also available.Customer designed products are also available. TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) M5 (Secondary Terminal)M5 (Secondary Terminal) min. 2.5 max. 3.5 TYPESTYPES ATD 1OATD 1O ATD 2OATD 2O A B C D E F G H I 28O 1O2 342 214 215 235 158 155 28O 1O2 427 26O 26O 295 158 155 23 23 www.esitas.comwww.esitas.com
  • 33. CURRENT TRANSFORMERSCURRENT TRANSFORMERS 3232 Technical DataTechnical Data INDOOR POST BUSBAR TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSINDOOR POST BUSBAR TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS (Um=3,6kV............24kV)(Um=3,6kV............24kV) - Up to 3 cores.- Up to 3 cores.* * For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility. ** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility. Secondary rated current (A)Secondary rated current (A) Metering classesMetering classes Protection classesProtection classes Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA) Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA) Short-time load (mechanical) (N)Short-time load (mechanical) (N) Insulation classInsulation class Ambient temperature (˚C)Ambient temperature (˚C) Altitude (m)Altitude (m) StandardStandard Weight (approx.) (kg)Weight (approx.) (kg) 1-51-5 O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1 5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1 max. 1OOmax. 1OO Practically UnlimitedPractically Unlimited 3OOO3OOO E -25 ........... +4O-25 ........... +4O**** 1OOO1OOO According to the customer requirementsAccording to the customer requirements 3535 4O4O 3838 TYPESTYPES Operating voltage, Um (kV)Operating voltage, Um (kV) Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV) Rated frequency (Hz)Rated frequency (Hz) Primary rated current (A)Primary rated current (A) 3,6 7,2 12 17,53,6 7,2 12 17,5 1O 2O 28 381O 2O 28 38 4O 6O 75 954O 6O 75 95 17,5 2417,5 24 38 5O38 5O 95 12595 125 5O-6O5O-6O 8OO-4OOO8OO-4OOO ATN 17ATN 17 ATN 24ATN 24ESO 17CESO 17C
  • 34. 3333 -- All dimensions are in mm.All dimensions are in mm. - Tolerance is DIN 7168-g.Tolerance is DIN 7168-g. - Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information. - Customer designed products are also available.Customer designed products are also available. M5 (Secondary Terminal)M5 (Secondary Terminal) 2,5 3,5 TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) min. max. INDOOR POST BUSBAR TYPE CAST RESIN INSULATEDINDOOR POST BUSBAR TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING (Um=3,6kV............24kV)(Um=3,6kV............24kV) ATN 17 (width 15Omm )ATN 17 (width 15Omm ) ATN 17ATN 17 (width 28Omm )(width 28Omm ) ATN 24ATN 24 ESO 17CESO 17C www.esitas.comwww.esitas.com
  • 35. CURRENT TRANSFORMERSCURRENT TRANSFORMERS 3434 Technical DataTechnical Data OUTDOOR DRY TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSOUTDOOR DRY TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS (Um=3,6kV ....................24kV)(Um=3,6kV ....................24kV) - ATH 2O up to 1 core.- ATH 2O up to 1 core.* - ATH 21 up to 2 cores.- ATH 21 up to 2 cores.* - ATH 22 up to 3 cores.- ATH 22 up to 3 cores.* * For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility. Secondary rated current (A)Secondary rated current (A) Primary reconnection (A)Primary reconnection (A) Metering classesMetering classes Protection classesProtection classes Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA) Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA) Short-time load (mechanical) (N)Short-time load (mechanical) (N) Insulation classInsulation class Min. creepage distance (mm)Min. creepage distance (mm) Altitude (m)Altitude (m) StandardStandard Weight (approx.) (kg)Weight (approx.) (kg) 1-51-5 O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1 5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1 max. 1OOO x Inmax. 1OOO x In 2,5 x lth2,5 x lth 24OO24OO E 56O56O 825825 77O77O According to the customer requirementsAccording to the customer requirements According to the customer requirementsAccording to the customer requirements 2424 3535 7878 TYPESTYPES Operating voltage, Um (kV)Operating voltage, Um (kV) Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV) Rated frequency (Hz)Rated frequency (Hz) Primary rated current (A)Primary rated current (A) 3,6 7,2 123,6 7,2 12 1O 2O 281O 2O 28 4O 6O 754O 6O 75 17,5 2417,5 24 38 5O38 5O 95 12595 125 5O-6O5O-6O 5-125O5-125O 5-25OO5-25OO 2x5 - 2x4OO2x5 - 2x4OO 2x5 - 2x6OO2x5 - 2x6OO ATH 2OATH 2O ATH 21ATH 21 ATH 22ATH 22 For the connectionFor the connection of aluminium conductorsof aluminium conductors steel reinforcedsteel reinforced
  • 36. OUTDOOR DRY TYPE CAST RESIN INSULATEDOUTDOOR DRY TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING (Um=3,6kV ....................24kV)(Um=3,6kV ....................24kV) 3535 -- All dimensions are in mm.All dimensions are in mm. -- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information. -- Customer designed products are also available.Customer designed products are also available. TYPESTYPES ATH 2OATH 2O A B C D E F G H 245 1O5 max. 35O max. 37O max. 38O max. 225 max. 34O max. 415 22O 178 175 2O ATH 21ATH 21 35O 165 3OO 27O 2OO 65 ATH 22ATH 22 4OO 195 37O 34O 25O 7O M6 (Secondary Terminal)M6 (Secondary Terminal) 3 5 M12 (Primary & Ground Terminal)M12 (Primary & Ground Terminal) 6O 7O TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) min. max. www.esitas.comwww.esitas.com
  • 37. CURRENT TRANSFORMERSCURRENT TRANSFORMERS 3636 Technical DataTechnical Data Types: ATH 3OTypes: ATH 3O ATH 32ATH 32 OUTDOOR DRY TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSOUTDOOR DRY TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS (Um=36kV)(Um=36kV) - ATH 3O up to 2 cores.- ATH 3O up to 2 cores.* - ATH 32 up to 3 cores.- ATH 32 up to 3 cores.* * For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility. Secondary rated current (A)Secondary rated current (A) Primary reconnection (A)Primary reconnection (A) Metering classesMetering classes Protection classesProtection classes Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA) Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA) Short-time load (mechanical) (N)Short-time load (mechanical) (N) Insulation classInsulation class Min. creepage distance (mm)Min. creepage distance (mm) Altitude (m)Altitude (m) StandardStandard Weight (approx.) (kg)Weight (approx.) (kg) 1-51-5 O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1 5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1 max. 1OOO x Inmax. 1OOO x In 2,5 x lth2,5 x lth 25OO25OO E 114O114O According to the customer requirementsAccording to the customer requirements According to the customer requirementsAccording to the customer requirements 4747 8585 TYPESTYPES Operating voltage, Um (kV)Operating voltage, Um (kV) Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV) Rated frequency (Hz)Rated frequency (Hz) Primary rated current (A)Primary rated current (A) 3636 7O7O 17O17O 5O-6O5O-6O 5-25OO5-25OO 2x5 - 2x6OO2x5 - 2x6OO ATH 3OATH 3O ATH 32ATH 32 For the connectionFor the connection of aluminium conductorsof aluminium conductors steel reinforcedsteel reinforced
  • 38. OUTDOOR DRY TYPE CAST RESIN INSULATEDOUTDOOR DRY TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING (Um=36kV)(Um=36kV) 3737 -- All dimensions are in mm.All dimensions are in mm. - Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information. - Customer designed products are also available.Customer designed products are also available. TYPESTYPES ATH 3OATH 3O A B C D E F G H 35O 165 max. 465 max. 477 max. 34O max. 4O3 3OO 27O 2OO 65 ATH 32ATH 32 39O 19O 35O 32O 25O 65 M6 (Secondary Terminal)M6 (Secondary Terminal) 3 5 M12 (Primary & Ground Terminal)M12 (Primary & Ground Terminal) 6O 7O TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) min. max. www.esitas.comwww.esitas.com
  • 39. CURRENT TRANSFORMERSCURRENT TRANSFORMERS 3838 Technical DataTechnical Data Types: ATH 3O-NTypes: ATH 3O-N ATH 32-NATH 32-N OUTDOOR DRY TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSOUTDOOR DRY TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS (Um=36kV)(Um=36kV) - ATH 3O-N up to 2 cores.- ATH 3O-N up to 2 cores.* - ATH 32-N up to 3 cores.- ATH 32-N up to 3 cores.* * For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility. Secondary rated current (A)Secondary rated current (A) Primary reconnection (A)Primary reconnection (A) Metering classesMetering classes Protection classesProtection classes Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA) Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA) Short-time load (mechanical) (N)Short-time load (mechanical) (N) Insulation classInsulation class Min. creepage distance (mm)Min. creepage distance (mm) Altitude (m)Altitude (m) StandardStandard Weight (approx.) (kg)Weight (approx.) (kg) 1-51-5 O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1 5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1 max. 1OOO x Inmax. 1OOO x In 2,5 x lth2,5 x lth 25OO25OO E 114O114O According to the customer requirementsAccording to the customer requirements According to the customer requirementsAccording to the customer requirements 4747 8585 TYPESTYPES Operating voltage, Um (kV)Operating voltage, Um (kV) Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV) Rated frequency (Hz)Rated frequency (Hz) Primary rated current (A)Primary rated current (A) 3636 7O7O 17O17O 5O-6O5O-6O 5-25OO5-25OO 2x5 - 2x6OO2x5 - 2x6OO ATH 3O-NATH 3O-N ATH 32-NATH 32-N For the connectionFor the connection of aluminium conductorsof aluminium conductors steel reinforcedsteel reinforced
  • 40. OUTDOOR DRY TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGOUTDOOR DRY TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWING (Um=36kV)(Um=36kV) 3939 -- All dimensions are in mm.All dimensions are in mm. -- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information. -- Customer designed products are also available.Customer designed products are also available. TYPESTYPES ATH 3O-NATH 3O-N A B C D E F G H 35O 165 max. 465 max. 474 max. 34O max. 4OO 3OO 27O 2OO 65 ATH 32-NATH 32-N 39O 173 35O 32O 25O 65 M6 (Secondary Terminal)M6 (Secondary Terminal) 3 5 M12 (PrimaryM12 (Primary TerminalTerminal) 6O 7O TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) min. max. www.esitas.comwww.esitas.com
  • 41. CURRENT TRANSFORMERSCURRENT TRANSFORMERS 4040 Technical DataTechnical Data Types: ATH 52Types: ATH 52 OUTDOOR DRY TYPE CAST RESIN INSULATED CURRENT TRANSFORMERSOUTDOOR DRY TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS (Um=52kV)(Um=52kV) - Up to 2 cores.- Up to 2 cores.* * For more cores please contact with ESITAS for feasibility.For more cores please contact with ESITAS for feasibility. Secondary rated current (A)Secondary rated current (A) Primary reconnection (A)Primary reconnection (A) Metering classesMetering classes Protection classesProtection classes Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA) Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA) Short-time load (mechanical) (N)Short-time load (mechanical) (N) Insulation classInsulation class Min. creepage distance (mm)Min. creepage distance (mm) Altitude (m)Altitude (m) StandardStandard Weight (approx.) (kg)Weight (approx.) (kg) 1-51-5 O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1 5P- 1OP; CI:PX Acc. to IEC 6OO44-15P- 1OP; CI:PX Acc. to IEC 6OO44-1 max. 1OOO x Inmax. 1OOO x In 2,5 x lth2,5 x lth 25OO25OO E 16OO16OO According to the customer requirementsAccording to the customer requirements According to the customer requirementsAccording to the customer requirements 14O14O TYPESTYPES Operating voltage, Um (kV)Operating voltage, Um (kV) Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV) Rated frequency (Hz)Rated frequency (Hz) Primary rated current (A)Primary rated current (A) 5252 9595 25O25O 5O-6O5O-6O 5-25OO5-25OO 2x5 - 2x6OO2x5 - 2x6OO ATH 52ATH 52 For the connectionFor the connection of aluminium conductorsof aluminium conductors steel reinforcedsteel reinforced
  • 42. OUTDOOR DRY TYPE CAST RESIN INSULATEDOUTDOOR DRY TYPE CAST RESIN INSULATED C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING (Um=52kV )(Um=52kV ) 4141 -- All dimensions are in mm.All dimensions are in mm. - Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information. - Customer designed products are also available.Customer designed products are also available. M6 (Secondary Terminal)M6 (Secondary Terminal) 3 5 M12 (Primary & Ground Terminal)M12 (Primary & Ground Terminal) 6O 7O TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) min. max. www.esitas.comwww.esitas.com
  • 43.
  • 44.
  • 45. CURRENT TRANSFORMERSCURRENT TRANSFORMERS Technical DataTechnical Data Types: KAPTypes: KAP INDOOR KAP TYPE (CABLE TYPE) CAST RESIN INSULATEDINDOOR KAP TYPE (CABLE TYPE) CAST RESIN INSULATED ANDAND ENCLOSED BY PLASTIC COVERENCLOSED BY PLASTIC COVER CURRENT TRANSFORMERSCURRENT TRANSFORMERS (Um=O,72kV) - Width 35- Width 35, 55mm up to 1 core.55mm up to 1 core.* - Width 95- Width 95, 115mm up to 2 cores.115mm up to 2 cores.* * For more cores, please contact with ESITAS for feasibility.For more cores, please contact with ESITAS for feasibility. ** It can be produced according to customer’s specified ambient temperature. Please contact with ESITAS for feasibility.It can be produced according to customer’s specified ambient temperature. Please contact with ESITAS for feasibility. ) 4444 1-51-5 O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1 5P- 1OP; Acc. to IEC 6OO44-15P- 1OP; Acc. to IEC 6OO44-1 max. 1OOmax. 1OO Practically unlimitedPractically unlimited E -25............+4O-25............+4O**** 1OOO1OOO According to the customer requirementsAccording to the customer requirements TYPESTYPES Secondary rated current (A)Secondary rated current (A) Metering classesMetering classes Protection classesProtection classes Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA) Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA) Insulation classInsulation class Ambient temperatureAmbient temperature (˚C)(˚C) Altitude (m)Altitude (m) StandardStandard Operating voltage, Um (kV)Operating voltage, Um (kV) Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV) Rated frequency (Hz)Rated frequency (Hz) Primary rated currentPrimary rated current (A)(A) O,72O,72 3 - 5O-6O5O-6O 4O ........... 3OOO4O ........... 3OOO KAPKAP
  • 46. * All dimensions are in mm.All dimensions are in mm. INDOOR KAP TYPE (CABLE TYPE) CAST RESIN INSULATED AND ENCLOSED BY PLASTIC COVERINDOOR KAP TYPE (CABLE TYPE) CAST RESIN INSULATED AND ENCLOSED BY PLASTIC COVER C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING (Um=O,72kV)(Um=O,72kV) NONO TYPETYPE IDID ODOD H K O A B C 1 KAP-4OKAP-4O/19O-3519O-35 4O4O 19O19O 241241 3535 119119 15O15O 13O13O - 2 KAP-4OKAP-4O/19O-5519O-55 4O4O 19O19O 241241 5555 119119 15O15O 13O13O 2525 3 KAP-4OKAP-4O/19O-9519O-95 4O4O 19O19O 241241 9595 119119 15O15O 13O13O 4O4O 4 KAP-4OKAP-4O/19O-11519O-115 4O4O 19O19O 241241 115115 119119 17O17O 15O15O 4O4O 5 KAP-6OKAP-6O/19O-3519O-35 6O6O 19O19O 241241 3535 119119 15O15O 13O13O - 6 KAP-6OKAP-6O/19O-5519O-55 6O6O 19O19O 241241 5555 119119 15O15O 13O13O 2525 7 KAP-6OKAP-6O/19O-9519O-95 6O6O 19O19O 241241 9595 119119 15O15O 13O13O 4O4O 8 KAP-6OKAP-6O/19O-11519O-115 6O6O 19O19O 241241 115115 119119 17O17O 15O15O 4O4O 9 KAP-8OKAP-8O/19O-3519O-35 8O8O 19O19O 241241 3535 119119 15O15O 13O13O - 1O1O KAP-8OKAP-8O/19O-5519O-55 8O8O 19O19O 241241 5555 119119 15O15O 13O13O 2525 1111 KAP-8OKAP-8O/19O-9519O-95 8O8O 19O19O 241241 9595 119119 15O15O 13O13O 4O4O 1212 KAP-8OKAP-8O/19O-11519O-115 8O8O 19O19O 241241 115115 119119 17O17O 15O15O 4O4O 1313 KAP-4OKAP-4O/21O-3521O-35 4O4O 21O21O 261261 3535 129129 15O15O 13O13O - 1414 KAP-4OKAP-4O/21O-5521O-55 4O4O 21O21O 261261 5555 129129 15O15O 13O13O 2525 1515 KAP-4OKAP-4O/21O-9521O-95 4O4O 21O21O 261261 9595 129129 15O15O 13O13O 4O4O 1616 KAP-4OKAP-4O/21O-11521O-115 4O4O 21O21O 261261 115115 129129 17O17O 15O15O 4O4O 1717 KAP-6OKAP-6O/21O-3521O-35 6O6O 21O21O 261261 3535 129129 15O15O 13O13O - 1818 KAP-6OKAP-6O/21O-5521O-55 6O6O 21O21O 261261 5555 129129 15O15O 13O13O 2525 1919 KAP-6OKAP-6O/21O-9521O-95 6O6O 21O21O 261261 9595 129129 15O15O 13O13O 4O4O 2O2O KAP-6OKAP-6O/21O-11521O-115 6O6O 21O21O 261261 115115 129129 17O17O 15O15O 4O4O 2121 KAP-8OKAP-8O/21O-3521O-35 8O8O 21O21O 261261 3535 129129 15O15O 13O13O - 2222 KAP-8OKAP-8O/21O-5521O-55 8O8O 21O21O 261261 5555 129129 15O15O 13O13O 2525 2323 KAP-8OKAP-8O/21O-9521O-95 8O8O 21O21O 261261 9595 129129 15O15O 13O13O 4O4O 2424 KAP-8OKAP-8O/21O-11521O-115 8O8O 21O21O 261261 115115 129129 17O17O 15O15O 4O4O NONO TYPETYPE IDID ODOD H K O A B C 2525 KAP-4OKAP-4O/25O-3525O-35 4O4O 25O25O 3O13O1 3535 149149 15O15O 13O13O - 2626 KAP-4OKAP-4O/25O-5525O-55 4O4O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525 2727 KAP-4OKAP-4O/25O-9525O-95 4O4O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O 2828 KAP-4OKAP-4O/25O-11525O-115 4O4O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O 2929 KAP-6OKAP-6O/25O-3525O-35 6O6O 25O25O 3O13O1 3535 149149 15O15O 13O13O - 3O3O KAP-6OKAP-6O/25O-5525O-55 6O6O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525 3131 KAP-6OKAP-6O/25O-9525O-95 6O6O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O 3232 KAP-6OKAP-6O/25O-11525O-115 6O6O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O 3333 KAP-8OKAP-8O/25O-3525O-35 8O8O 25O25O 3O13O1 3535 149149 15O15O 13O13O - 3434 KAP-8OKAP-8O/25O-5525O-55 8O8O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525 3535 KAP-8OKAP-8O/25O-9525O-95 8O8O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O 3636 KAP-8OKAP-8O/25O-11525O-115 8O8O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O 3737 KAP-1OOKAP-1OO/25O-3525O-35 1OO1OO 25O25O 3O13O1 3535 149149 15O15O 13O13O - 3838 KAP-1OOKAP-1OO/25O-5525O-55 1OO1OO 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525 3939 KAP-1OOKAP-1OO/25O-9525O-95 1OO1OO 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O 4O4O = KAP-1OOKAP-1OO/25O-11525O-115 1OO1OO 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O 4141 KAP-12OKAP-12O/25O-5525O-55 12O12O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525 4242 KAP-12OKAP-12O/25O-9525O-95 12O12O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O 4343 KAP-12OKAP-12O/25O-11525O-115 12O12O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O 4444 KAP-15OKAP-15O/25O-5525O-55 15O15O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525 4545 KAP-15OKAP-15O/25O-9525O-95 15O15O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O 4646 KAP-15OKAP-15O/25O-11525O-115 15O15O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O 4747 KAP-1OOKAP-1OO/19O-5519O-55 1OO1OO 19O19O 241241 5555 119119 15O15O 13O13O 2525 4848 KAP-1OOKAP-1OO/19O-9519O-95 1OO1OO 19O19O 241241 9595 119119 15O15O 13O13O 4O4O 4949 KAP-1OOKAP-1OO/19O-11519O-115 1OO1OO 19O19O 241241 115115 119119 17O17O 15O15O 4O4O 5O5O KAP-17OKAP-17O/25O-5525O-55 17O17O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525 5151 KAP-17OKAP-17O/25O-9525O-95 17O17O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O 5252 KAP-17OKAP-17O/25O-11525O-115 17O17O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O KAP TYPES (DIMENSIONS)KAP TYPES (DIMENSIONS)* KAP TYPE ( With Horizontal Mounted Plates)KAP TYPE ( With Horizontal Mounted Plates) CURRENT TRANSFORMERCURRENT TRANSFORMER As can be seen In the below tables there are various dimensions ofAs can be seen In the below tables there are various dimensions of KAP Types. Please contact with ESiTAS for feasibility of required transformer'sKAP Types. Please contact with ESiTAS for feasibility of required transformer's which have different ratiowhich have different ratio, classclass, burden and dimensions.burden and dimensions. ! Attention : Transformers which have 35mm height ( K)Attention : Transformers which have 35mm height ( K), there Is only one connection plate.there Is only one connection plate. M5 (Secondary Terminal)M5 (Secondary Terminal) 2,5 3,5 TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) min. max. 4545 www.esitas.comwww.esitas.com
  • 47. CURRENT TRANSFORMERSCURRENT TRANSFORMERS * All dimensions are in mm.All dimensions are in mm. INDOOR KAP TYPE (CABLE TYPE) CAST RESIN INSULATED AND ENCLOSED BY PLASTIC COVERINDOOR KAP TYPE (CABLE TYPE) CAST RESIN INSULATED AND ENCLOSED BY PLASTIC COVER C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING (Um=O,72kV)(Um=O,72kV) KAP TYPES (DIMENSIONS)KAP TYPES (DIMENSIONS)* KAP TYPE ( With Vertical Mounted Plates)KAP TYPE ( With Vertical Mounted Plates) CURRENT TRANSFORMERCURRENT TRANSFORMER As can be seen In the below tables there are various dimensions ofAs can be seen In the below tables there are various dimensions of KAP Types. Please contact with ESiTAS for feasibility of required transformer'sKAP Types. Please contact with ESiTAS for feasibility of required transformer's which have different ratio, class, burden and dimensions.which have different ratio, class, burden and dimensions. M5 (Secondary Terminal)M5 (Secondary Terminal) 2,5 3,5 TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) min. max. 4646 NONO TYPETYPE IDID ODOD H K O A B C 1 KAP-4OKAP-4O/19O-3519O-35 4O4O 19O19O 241241 3535 119119 15O15O 13O13O 4O4O 2 KAP-4OKAP-4O/19O-5519O-55 4O4O 19O19O 241241 5555 119119 15O15O 13O13O 2525 3 KAP-4OKAP-4O/19O-9519O-95 4O4O 19O19O 241241 9595 119119 15O15O 13O13O 4O4O 4 KAP-4OKAP-4O/19O-11519O-115 4O4O 19O19O 241241 115115 119119 17O17O 15O15O 4O4O 5 KAP-6OKAP-6O/19O-3519O-35 6O6O 19O19O 241241 3535 119119 15O15O 13O13O 4O4O 6 KAP-6OKAP-6O/19O-5519O-55 6O6O 19O19O 241241 5555 119119 15O15O 13O13O 2525 7 KAP-6OKAP-6O/19O-9519O-95 6O6O 19O19O 241241 9595 119119 15O15O 13O13O 4O4O 8 KAP-6OKAP-6O/19O-11519O-115 6O6O 19O19O 241241 115115 119119 17O17O 15O15O 4O4O 9 KAP-8OKAP-8O/19O-3519O-35 8O8O 19O19O 241241 3535 119119 15O15O 13O13O 4O4O 1O1O KAP-8OKAP-8O/19O-5519O-55 8O8O 19O19O 241241 5555 119119 15O15O 13O13O 2525 1111 KAP-8OKAP-8O/19O-9519O-95 8O8O 19O19O 241241 9595 119119 15O15O 13O13O 4O4O 1212 KAP-8OKAP-8O/19O-11519O-115 8O8O 19O19O 241241 115115 119119 17O17O 15O15O 4O4O 1313 KAP-4OKAP-4O/21O-3521O-35 4O4O 21O21O 261261 3535 129129 15O15O 13O13O 4O4O 1414 KAP-4OKAP-4O/21O-5521O-55 4O4O 21O21O 261261 5555 129129 15O15O 13O13O 2525 1515 KAP-4OKAP-4O/21O-9521O-95 4O4O 21O21O 261261 9595 129129 15O15O 13O13O 4O4O 1616 KAP-4OKAP-4O/21O-11521O-115 4O4O 21O21O 261261 115115 129129 17O17O 15O15O 4O4O 1717 KAP-6OKAP-6O/21O-3521O-35 6O6O 21O21O 261261 3535 129129 15O15O 13O13O 4O4O 1818 KAP-6OKAP-6O/21O-5521O-55 6O6O 21O21O 261261 5555 129129 15O15O 13O13O 2525 1919 KAP-6OKAP-6O/21O-9521O-95 6O6O 21O21O 261261 9595 129129 15O15O 13O13O 4O4O 2O2O KAP-6OKAP-6O/21O-11521O-115 6O6O 21O21O 261261 115115 129129 17O17O 15O15O 4O4O 2121 KAP-8OKAP-8O/21O-3521O-35 8O8O 21O21O 261261 3535 129129 15O15O 13O13O 4O4O 2222 KAP-8OKAP-8O/21O-5521O-55 8O8O 21O21O 261261 5555 129129 15O15O 13O13O 2525 2323 KAP-8OKAP-8O/21O-9521O-95 8O8O 21O21O 261261 9595 129129 15O15O 13O13O 4O4O 2424 KAP-8OKAP-8O/21O-11521O-115 8O8O 21O21O 261261 115115 129129 17O17O 15O15O 4O4O NONO TYPETYPE IDID ODOD H K O A B C 2525 KAP-4OKAP-4O/25O-3525O-35 4O4O 25O25O 3O13O1 3535 149149 15O15O 13O13O 4O4O 2626 KAP-4OKAP-4O/25O-5525O-55 4O4O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525 2727 KAP-4OKAP-4O/25O-9525O-95 4O4O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O 2828 KAP-4OKAP-4O/25O-11525O-115 4O4O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O 2929 KAP-6OKAP-6O/25O-3525O-35 6O6O 25O25O 3O13O1 3535 149149 15O15O 13O13O 4O4O 3O3O KAP-6OKAP-6O/25O-5525O-55 6O6O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525 3131 KAP-6OKAP-6O/25O-9525O-95 6O6O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O 3232 KAP-6OKAP-6O/25O-11525O-115 6O6O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O 3333 KAP-8OKAP-8O/25O-3525O-35 8O8O 25O25O 3O13O1 3535 149149 15O15O 13O13O 4O4O 3434 KAP-8OKAP-8O/25O-5525O-55 8O8O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525 3535 KAP-8OKAP-8O/25O-9525O-95 8O8O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O 3636 KAP-8OKAP-8O/25O-11525O-115 8O8O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O 3737 KAP-1OOKAP-1OO/25O-3525O-35 1OO1OO 25O25O 3O13O1 3535 149149 15O15O 13O13O 4O4O 3838 KAP-1OOKAP-1OO/25O-5525O-55 1OO1OO 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525 3939 KAP-1OOKAP-1OO/25O-9525O-95 1OO1OO 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O 4O4O = KAP-1OOKAP-1OO/25O-11525O-115 1OO1OO 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O 4141 KAP-12OKAP-12O/25O-5525O-55 12O12O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525 4242 KAP-12OKAP-12O/25O-9525O-95 12O12O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O 4343 KAP-12OKAP-12O/25O-11525O-115 12O12O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O 4444 KAP-15OKAP-15O/25O-5525O-55 15O15O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525 4545 KAP-15OKAP-15O/25O-9525O-95 15O15O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O 4646 KAP-15OKAP-15O/25O-11525O-115 15O15O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O 4747 KAP-1OOKAP-1OO/19O-5519O-55 1OO1OO 19O19O 241241 5555 119119 15O15O 13O13O 2525 4848 KAP-1OOKAP-1OO/19O-9519O-95 1OO1OO 19O19O 241241 9595 119119 15O15O 13O13O 4O4O 4949 KAP-1OOKAP-1OO/19O-11519O-115 1OO1OO 19O19O 241241 115115 119119 17O17O 15O15O 4O4O 5O5O KAP-17OKAP-17O/25O-5525O-55 17O17O 25O25O 3O13O1 5555 149149 15O15O 13O13O 2525 5151 KAP-17OKAP-17O/25O-9525O-95 17O17O 25O25O 3O13O1 9595 149149 15O15O 13O13O 4O4O 5252 KAP-17OKAP-17O/25O-11525O-115 17O17O 25O25O 3O13O1 115115 149149 17O17O 15O15O 4O4O
  • 48. - Inside Diameters: 8O- Inside Diameters: 8O / 1OO1OO / 12O12O Technical DataTechnical Data Types: A-KAPTypes: A-KAP INDOOR A-KAP TYPE (SPLIT TYPE) CAST RESIN INSULATEDINDOOR A-KAP TYPE (SPLIT TYPE) CAST RESIN INSULATED ANDAND ENCLOSED BY PLASTIC COVERENCLOSED BY PLASTIC COVER CURRENT TRANSFORMERSCURRENT TRANSFORMERS (Um=O,72kV)(Um=O,72kV) * It can be produced according to customer’s specified ambient temperature. Please contact with ESITAS for feasibility.It can be produced according to customer’s specified ambient temperature. Please contact with ESITAS for feasibility. 4747 1-51-5 O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1 5P- 1OP; Acc. to IEC 6OO44-15P- 1OP; Acc. to IEC 6OO44-1 max. 1OOmax. 1OO Practically unlimitedPractically unlimited E -25............+4O-25............+4O* 1OOO1OOO According to the customer requirementsAccording to the customer requirements TYPESTYPES Secondary rated current (A)Secondary rated current (A) Metering classesMetering classes Protection classesProtection classes Rated short-time thermal current (lth) (1s) (kA)Rated short-time thermal current (lth) (1s) (kA) Rated dynamic current (ldyn) (kA)Rated dynamic current (ldyn) (kA) Insulation classInsulation class Ambient temperatureAmbient temperature (˚C)(˚C) Altitude (m)Altitude (m) StandardStandard Operating voltage, Um (kV)Operating voltage, Um (kV) Rated power-frequency withstand voltage (1 minute) (kV)Rated power-frequency withstand voltage (1 minute) (kV) Rated frequency (Hz)Rated frequency (Hz) Primary rated currentPrimary rated current (A)(A) O,72O,72 3 - 5O-6O5O-6O 5O ........... 2OOO5O ........... 2OOO A-KAPA-KAP www.esitas.comwww.esitas.com
  • 49. CURRENT TRANSFORMERSCURRENT TRANSFORMERS * All dimensions are in mm.All dimensions are in mm. INDOOR A-KAP TYPE (SPLIT TYPE) CAST RESIN INSULATED AND ENCLOSED BY PLASTIC COVERINDOOR A-KAP TYPE (SPLIT TYPE) CAST RESIN INSULATED AND ENCLOSED BY PLASTIC COVER C.T.’S TECHNICAL DRAWINGC.T.’S TECHNICAL DRAWING (Um=O,72kV)(Um=O,72kV) M5 (Secondary Terminal)M5 (Secondary Terminal) 2,5 3,5 TIGHTENING TORQUE (Nm)TIGHTENING TORQUE (Nm) min. max. NONO A 1 8O8O 1OO1OO 12O12O 2 3 4848
  • 50. 4949 RING TYPE CURRENT TRANSFORMERSRING TYPE CURRENT TRANSFORMERS (Um=O,72kV)(Um=O,72kV) INDOOR RING TYPESINDOOR RING TYPES BUSHING TYPESBUSHING TYPES OUTDOOR RING TYPESOUTDOOR RING TYPES - Cable type.- Cable type. - Insulated by cast resin.- Insulated by cast resin. - Applicable for measurement and protection purposes.- Applicable for measurement and protection purposes. - For power transformers.- For power transformers. - Suitable for operation under oil continuous 13O- Suitable for operation under oil continuous 13O˚C.C. - Insulated by Insulation paper or Polyester tape.- Insulated by Insulation paper or Polyester tape. - Applicable for measurement and protection purposes.- Applicable for measurement and protection purposes. - Dimensions : According to the customer requirements.Dimensions : According to the customer requirements. - Standards : According to the customer requirements.Standards : According to the customer requirements. - Please contact with ESITAS for feasibility of required transformer's which have different ratio, class, burden and dimensions.Please contact with ESITAS for feasibility of required transformer's which have different ratio, class, burden and dimensions. www.esitas.comwww.esitas.com
  • 51. CURRENT TRANSFORMERSCURRENT TRANSFORMERS 5050 Technical DataTechnical Data Types: LPCT-115Types: LPCT-115 INDOOR TYPE LPCTINDOOR TYPE LPCT (Low Power Current Transformer) (Cable Type)(Low Power Current Transformer) (Cable Type) (Um=O, 72kV)(Um=O, 72kV) - LPCT-115 is defining low power current transformer with- LPCT-115 is defining low power current transformer with voltage output in compliance with IEC 6OO44-8.voltage output in compliance with IEC 6OO44-8. - It is designed for measuring nominal currents of 5A to- It is designed for measuring nominal currents of 5A to 125O A with ratio 1OOA125O A with ratio 1OOA / 22,5mV. Thus it should be used with a22,5mV. Thus it should be used with a digital relay which have 1OOAdigital relay which have 1OOA // 22,5mV input with LPCT.22,5mV input with LPCT. - Esitas LPCT Set is composed of three LPCT and one digital- Esitas LPCT Set is composed of three LPCT and one digital relay. In case of preffered set without relay, Esitas has to berelay. In case of preffered set without relay, Esitas has to be informed about the relay that will be usedinformed about the relay that will be used, - The sensor is delivered with cable which is between 5m - 8m- The sensor is delivered with cable which is between 5m - 8m upon customer request.upon customer request. Advantages :Advantages : -Same transformer is usable for nominal currents of 5A to 125OA.-Same transformer is usable for nominal currents of 5A to 125OA. - Accurracy warranty throughout the range :- Accurracy warranty throughout the range : •• Protection : 5A-4OkA ; class 5PProtection : 5A-4OkA ; class 5P •• Measuring: 1OOA-125OA; class O,5 (class O,75 for 2OA, class 1,5 for 5A).Measuring: 1OOA-125OA; class O,5 (class O,75 for 2OA, class 1,5 for 5A). Simple Assembly :Simple Assembly : - Ready for connection secondary cables.- Ready for connection secondary cables. - Simple connection with insulated cable for all types cubicles.- Simple connection with insulated cable for all types cubicles. Safety Operation :Safety Operation : - Openable secondary circuit under load.- Openable secondary circuit under load. cable between 5m - 8mcable between 5m - 8m upon customer request.upon customer request. Class of protectionClass of protection Class of measuringClass of measuring Accuracy limit factor (Kalf)Accuracy limit factor (Kalf) Rated short - time current (kARated short - time current (kA / 1s)1s) Insulation level (kV)Insulation level (kV) Frequency (Hz)Frequency (Hz) 5P5P 15O15O 4O4O O,72O,72 / 33 / -- 5O - 6O5O - 6O 2 TYPESTYPES StandardStandard Minimum primary curent (A)Minimum primary curent (A) Rated primary current (A)Rated primary current (A) Rated secondary voltage (mV)Rated secondary voltage (mV) Rated maximum primary current (A)Rated maximum primary current (A) IEC 6OO44-8IEC 6OO44-8 5 1OO1OO 22,522,5 125O125O O,5 (1OOA - 125OA), O,75 (2OA), 1,5 (5A)O,5 (1OOA - 125OA), O,75 (2OA), 1,5 (5A) LPCT - 115LPCT - 115
  • 52. 5151 Technical DataTechnical Data Types: LPCT-16OTypes: LPCT-16O INDOOR TYPE LPCTINDOOR TYPE LPCT (Low Power Current Transformer) (Cable Type)(Low Power Current Transformer) (Cable Type) (Um=O, 72kV)(Um=O, 72kV) - LPCT-16O is defining low power current transformer with- LPCT-16O is defining low power current transformer with voltage output in compliance with IEC 6OO44-8.voltage output in compliance with IEC 6OO44-8. - It is designed for measuring nominal currents of 5A to- It is designed for measuring nominal currents of 5A to 2OOO A with ratio 1OOA2OOO A with ratio 1OOA / 22,5mV. Thus it should be used with a22,5mV. Thus it should be used with a digital relay which have 1OOAdigital relay which have 1OOA // 22,5mV input with LPCT.22,5mV input with LPCT. - Esitas LPCT Set is composed of three LPCT and one digital- Esitas LPCT Set is composed of three LPCT and one digital relay. In case of preffered set without relay, Esitas has to berelay. In case of preffered set without relay, Esitas has to be informed about the relay that will be usedinformed about the relay that will be used, - The sensor is delivered with cable which is between 5m - 8m- The sensor is delivered with cable which is between 5m - 8m upon customer request.upon customer request. Advantages :Advantages : -Same transformer is usable for nominal currents of 5A to 2OOOA.-Same transformer is usable for nominal currents of 5A to 2OOOA. - Accurracy warranty throughout the range :- Accurracy warranty throughout the range : •• Protection : 5A-4OkA ; class 5PProtection : 5A-4OkA ; class 5P •• Measuring: 1OOA-2OOOA; class O,5 (class O,75 for 2OA, class 1,5 for 5A).Measuring: 1OOA-2OOOA; class O,5 (class O,75 for 2OA, class 1,5 for 5A). Simple Assembly :Simple Assembly : - Ready for connection secondary cables.- Ready for connection secondary cables. - Simple connection with insulated cable for all types cubicles.- Simple connection with insulated cable for all types cubicles. Safety Operation :Safety Operation : - Openable secondary circuit under load.- Openable secondary circuit under load. cable between 5m - 8mcable between 5m - 8m upon customer request.upon customer request. Class of protectionClass of protection Class of measuringClass of measuring Accuracy limit factor (Kalf)Accuracy limit factor (Kalf) Rated short - time current (kARated short - time current (kA / 1s)1s) Insulation level (kV)Insulation level (kV) Frequency (Hz)Frequency (Hz) Burden (Rbr)Burden (Rbr) 5P5P 4OO4OO 4O4O O,72O,72 / 33 / -- 5O - 6O5O - 6O 2 TYPESTYPES StandardStandard Minimum primary curent (A)Minimum primary curent (A) Rated primary current (A)Rated primary current (A) Rated secondary voltage (mV)Rated secondary voltage (mV) Rated maximum primary current (A)Rated maximum primary current (A) IEC 6OO44-8IEC 6OO44-8 5 1OO1OO 22,522,5 2OOO2OOO O,5 (1OOA - 2OOOA), O,75 (2OA), 1,5 (5A)O,5 (1OOA - 2OOOA), O,75 (2OA), 1,5 (5A) LPCT - 16OLPCT - 16O www.esitas.comwww.esitas.com
  • 53.
  • 54.
  • 55. VOLTAGE TRANSFORMERSVOLTAGE TRANSFORMERS Voltage TransformersVoltage Transformers An instrument transformer in which the secondary voltage, in normal conditions of use, is substantially proportional to the primaryAn instrument transformer in which the secondary voltage, in normal conditions of use, is substantially proportional to the primary voltage and differs in phase from it by an angle which is approximately zero for an appropriate direction of thevoltage and differs in phase from it by an angle which is approximately zero for an appropriate direction of the connections.connections. It isolates the primary side rated voltage from the connected instruments and protection circuits and convert the primaryIt isolates the primary side rated voltage from the connected instruments and protection circuits and convert the primary voltage into a measurable secondary voltage, which is true in magnitude and phase.voltage into a measurable secondary voltage, which is true in magnitude and phase. Primary WindingPrimary Winding The winding to which the voltage to be transformed is applied.The winding to which the voltage to be transformed is applied. Secondary WindingSecondary Winding The winding, which supplies the voltage circuits of measuring instruments, meters, relays or similar apparatus.The winding, which supplies the voltage circuits of measuring instruments, meters, relays or similar apparatus. Rated Primary VoltageRated Primary Voltage The value of the primary voltage, which appears in the designation of the transformer and on which its performance is based.The value of the primary voltage, which appears in the designation of the transformer and on which its performance is based. Rated Secondary VoltageRated Secondary Voltage The value of the secondary voltage, which appears in the designation of the transformer and on which its performanceThe value of the secondary voltage, which appears in the designation of the transformer and on which its performance isis based.based. Rated Transformation RatioRated Transformation Ratio The ratio of the rated primary to the rated secondary voltage.The ratio of the rated primary to the rated secondary voltage. Voltage Error (Ratio Error)Voltage Error (Ratio Error) The error which a transformer introduces into the measurement of a voltage and which arises when the actual transformationThe error which a transformer introduces into the measurement of a voltage and which arises when the actual transformation ratio is not equal to the transformation ratio.ratio is not equal to the transformation ratio. The voltage error, expressed in per cent, is given by the formula:The voltage error, expressed in per cent, is given by the formula: Voltage ErrorVoltage Error % = WhereWhere Kn is the rated transformation ratio;Kn is the rated transformation ratio; Up is the actual primary voltage;Up is the actual primary voltage; Us is the actual secondary voltage when Up is applied under the conditions of measurement.Us is the actual secondary voltage when Up is applied under the conditions of measurement. Accuracy ClassAccuracy Class A designation assigned to a voltage transformer, the errors of which remain within specified limits under prescribed conditions of use.A designation assigned to a voltage transformer, the errors of which remain within specified limits under prescribed conditions of use. BurdenBurden The admittance of the secondary circuit expressed in siemens and power factor (lagging or leading)The admittance of the secondary circuit expressed in siemens and power factor (lagging or leading) Rated BurdenRated Burden The value of the burden on which the accuracy requirements are based on.The value of the burden on which the accuracy requirements are based on. Rated OutputRated Output The value of apparent power (in voltamperes at a specified power - factor), which the transformer is intended to supply to theThe value of apparent power (in voltamperes at a specified power - factor), which the transformer is intended to supply to the secondary circuit at the rated secondary voltage and with rated burden, connected to it.secondary circuit at the rated secondary voltage and with rated burden, connected to it. Rated Insulation LevelRated Insulation Level The combination of voltage values which characterizes the isolation of a transformer with regard to its capability to withstandThe combination of voltage values which characterizes the isolation of a transformer with regard to its capability to withstand dielectric stresses.dielectric stresses. Rated Voltage FactorRated Voltage Factor The multiplying factor to be applied to the rated primary voltage to determine the maximum voltage at which a transformer mustThe multiplying factor to be applied to the rated primary voltage to determine the maximum voltage at which a transformer must comply with the relevant thermal requirements for a specified time and with the relevant accuracy requirements.comply with the relevant thermal requirements for a specified time and with the relevant accuracy requirements. Kn Us - UpKn Us - Up UpUp x1OOx1OO 5454
  • 56. CONNECTION DIAGRAMSCONNECTION DIAGRAMS a n a n dada dndn Single Pole insulatedSingle Pole insulated voltage transformervoltage transformer with an open delta windingwith an open delta winding (e.g. 11OOO(e.g. 11OOO/√/√3: 1OO3: 1OO/√/√3V - 1OO3V - 1OO/3V)3V) Double pole insulatedDouble pole insulated voltage transformervoltage transformer (e.g. 11OOO: 1OOV)(e.g. 11OOO: 1OOV) It can be required for multi secondary winding and changeable ratios.It can be required for multi secondary winding and changeable ratios. A A NN Single Pole insulatedSingle Pole insulated voltage transformervoltage transformer (e.g. 11OOO(e.g. 11OOO/√/√3: 1OO3: 1OO/√/√3V)3V) V-Connection of Two Double Pole Insulated Voltage TransformersV-Connection of Two Double Pole Insulated Voltage Transformers Safety Operation Conditions for Voltage TransformersSafety Operation Conditions for Voltage Transformers -When the Secondary terminals are connected to the measuring or protection devices, one of the terminals should be earthed for-When the Secondary terminals are connected to the measuring or protection devices, one of the terminals should be earthed for safety as seen in Diagram-1.safety as seen in Diagram-1. a b a b A B A B a b A B R S T sr t A B a b V 5555 Diagram-1Diagram-1 www.esitas.comwww.esitas.com