Testing and Troubleshooting Fiber Optic Cables
1. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
Testing &
Troubleshooting of
Fibre Optic
Cables
2. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
If you are interested in further training or information,
please visit:
http://www.idc-online.com/slideshare
3. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
• To be discussed
– Fundamental concepts of optical measurement
– Standard fibre optic cable tests
– Standard fibre optic equipment tests
– Data transmission tests
– Laboratory measurements
4. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
Fundamental concepts of optical
measurement
• Optical power
– Measured in watts
– Optical measurements relate directly to electrical
measurements
– Optical energy measured as average of incoming
optical pulsed signal
5. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
Power for received optical waveform
POWER
(dBm)
TIME
Peak
Average
-16
-21
-23
6. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
– Light constructed of photons
– The higher the frequency the more energy in the photon
– Light energy is directly proportional to frequency and
inversely proportional to wavelength
– C = λ x f
– Planck’s law
– Q = h x f
• Q = energy of photon
• h = Planck’s constant
7. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
• Electrical power
– P = dQ / dt
Q = electron energy in joules
• Light power
– P = d (nQp) / dt
Qp = energy of a single photon
n = number of photons
8. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
• Power measurement
– Different materials used for different wavelengths
• e.g: Silicon reacts strongly at 850 µm
• Gallium arsenide reacts strongly at 1300 & 1550 µ m
– Therefore instruments are calibrated for the
different wavelengths
– Measure average power
9. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
• Bandwidth
– 3 dB limits as discussed
– For optical detector a 3 dB drop in optical level
represents a 6 dB drop in electrical output.
– Power meter shows correct optical power
10. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
Fibre optic tests
• Generally tests carried out before and after
installation
• Transmitter power test
• Connect Tx device via 2 m fibre to power meter
• Should be +/- 5% of specified figure
• Receiver performance test
• Connect Tx to Rx through optical fibre & attenuators.
Drop Rx level down to specified receiver sensitivity
• Check BER is < 10
-9
11. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
Measuring power into fibre
12. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
Testing the Receiver
13. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
• Continuity testing
– Very basic test of fibre continuity
– A continuity tester works at a 650µm
wavelength (red).
– Use physical observation
– Used for
• Tracing cores
• Finding fractures or bad splices with leaking
light
• Locating cores at intermediate points by
bending the fibres
14. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
• Insertion loss testing
– The most commonly used test
– Firstly calibrate the power meter to the optical
source
• Use a 2 metre fibre
• Generally to -10 dBm
– Check
• Calibration fibre is the same type as the installed
fibre
• Test wavelength is the same as the installed
operating wavelength
• Test source is the same as the installed source (led or
laser)
» Cont
15. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
• Test connectors are the same as the installed
connectors
– Cable insertion loss is calculated as
• Power source output value minus power meter
reading
– Carry out the test in both directions (diameter
and NA mismatches)
– Perform on every fibre in cable
– Where possible use the actual transmitter as a
source on some cores to compare the results
16. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
Insertion loss measurement
17. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
• Optical time domain reflectometry (OTDR)
– A short pulse is injected into the fibre
– The strength of the reflection shows attenuation
– The time delay in the return of the reflection shows
distance to the fault
– Reflections can be caused by
• Connectors, cracks, splices,impurities, breaks
• Continual reflection from backscatter (rayleigh scattering)
18. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
Trace fromTrace from an OTDROTDR
4 dB/Div
2km/Div
DeadBand
L
L
L
L
5 4 2
5
5
6 1
7
3
L = Loss introduced by inline obstruction
Distance
Attenuation
19. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
– Accuracies of 1m and 0.01dB loss are
achievable
– Carry out tests on the reel and after
installation
– This is a relative measurement therefore
should not be used for insertion loss
measurements.
– Carry out in both directions (different
diameters and NAs)
– For helical fibre laid cables use the fibre / cable
length ratio to calculate distance to fault
20. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
• Bit Error Rate testing
– BER = error bits received
total bits sent for a given period of time
– Normally 30 mins to 1 hr
– Expect residual BERof 10
-9
– Availability
• Time that link is available for uninterrupted use
over a 12 month period at a BER of 10
-12
• Expect 99.9999% or better
21. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
BER vs RSL for optical system
22. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
• Eye diagrams
– Provides analysis of the communications
system in real time
– Formed by continually overlapping the
signal at the Rx input on a scope (with a
pseudo random signal from the Tx)
– Measures
• Noise, jitter, period, duty cycle, settling time,
pulse width, rise time, fall time, overshoot,
undershoot, preshoot, settling time, pulse
quality and extinction ratio.
23. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
Eye diagram
Logic 1 overshoot
Logic 0 overshoot
Logic 1 undershoot
Logic 0 undershoot
Eye Width
10%
90%
Eye
Opening
Height
Rise
Time
Fall
Time
Noise and Distortion
Jitter
24. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
Other tests
• Laboratory tests
– Wavelength measurement
– Dispersion measurement
– Bandwidth measurement
– Phase measurement
– Polarisation measurement
– Number of travelling modes
– NA measurement
– Core diameter
25. Technology Training that WorksTechnology Training that Workswww.idc-online.com/slideshare
Thank You For Your Interest