Noise Control Best Practice noise 
TThhee EEnnvviirroonnmmeennttaall NNooiissee 
IInndduussttrryy iiss NNoott FFiitt ffoorr PPuurrppoossee…… 
PPeetteerr WWiillssoonn MMSScc.. MMIIOOAA 
Industrial Noise and Vibration Centre: www.invc.co.uk
www.invc.co.uk 
In Summary 
The “Noise Industry” 
• Generally displays a woeful ignorance of both diagnostic 
techniques and modern noise control methods 
The Victims 
• Thousands of people are therefore needlessly exposed to stressful 
noise from industrial / commercial premises over prolonged periods 
• Many unnecessary deaths consequently (BMJ and WHO reports) 
• Companies waste a fortune on inappropriate mitigation 
The Best Practice to Avoid the Problems 
• The diagnostic procedure that must be followed to evaluate any 
potential noise nuisance problem 
• Case studies illustrating poor practice in attempted mitigation 
(and failed mitigation) of common noise problems 
• Examples of best practice
www.invc.co.uk 
Noise Kills… 
WHO Report: 2011 
• Europe: c3% of deaths from heart attacks is attributable to long 
term exposure to (mainly nighttime) environmental noise 
• 2% of the population suffer from severe sleep disturbance 
• 15% suffer from serious annoyance 
• UK noise complaints increased by x5 over the last 20 years 
• Learning abilities of children badly affected 
BMJ Report: 2013 
• Environmental noise increases the risk of stroke and coronary 
heart disease due to raised blood pressure and hypertension 
• Near Heathrow, 24% increased hospital admissions due to stroke; 
21% increase due to coronary heart disease; 14% increase for 
cardiovascular disease cf low noise areas 
All dB(A) based – but many noise issues are low frequency, 
so these figures seriously underestimate the problem…
www.invc.co.uk 
BS 4142 – technically… 
BS 4142 is almost ubiquitous, largely because it exists… 
However, it is often (badly) applied to situations where it is not suitable. 
• BS 4142 is supposed to assess the likelihood of complaints from 
people inside a building by measuring dB(A) outside 
• inside rooms, the T.L. of windows shapes the spectrum, reducing mid 
and high frequency components - almost un-'A' weighting the sound 
• does not work well for noise containing low frequencies 
• 5dB(A) correction for noise with tones 
• tonal noise at 5dB(A) below non-tonal noise should be equally 
disturbing 
• should not be used where background noise levels are very low 
(<30dB(A))
www.invc.co.uk 
Environmental Noise Control is .... 
…not just about the overall level… 
• Effective noise control must be based on an accurate 
diagnosis that relates noise features to subjective impact, not 
just on assumptions about overall dB(A). 
• Although dB(A) may also be an additional planning / 
specification requirement, this is often a completely separate 
issue. 
• Noise control is an engineering problem that should be solved 
by engineering means at source wherever practical. 
• All the options must be considered, not just the high cost 
conventional palliatives of barriers, enclosures and silencers. 
http://www.invc.co.uk/noise/noise-control/environmental-noise-control/
www.invc.co.uk 
Attitude, Attitude, Attitude - Placebo Silencers
www.invc.co.uk 
Best Practice Elements 
• Attitude 
• Diagnosis - understand the cause of the subjective problem 
 based on detailed diagnosis, objective evaluation linking noise 
features to complaints – temporal and tonal components 
 link problem noise features to specific mechanical / aerodynamic 
plant elements. 
• Assess the Noise Control Options 
 based on current best practice. The majority of noise control 
recommendations that we see are either not fit for purpose or are 
far more costly than necessary. 
• Recommend / Implement Best Practice Noise Control Option 
 typically reduces noise control costs by 50% - 110%! 
 reduces the time required to solve problems (often from years to 
weeks)
www.invc.co.uk 
Diagnosis, Diagnosis, Diagnosis… 
You’re just guessing… 
The approach taken to mitigate noise problems is often 
based on guesswork. 
There should be no guesswork involved. 
•Temporal Diagnosis 
Events, intermittency, turn plant on and off, variation over 
time… 
•Frequency Content 
Broadband: octaves 
Tones: narrow band frequency analysis 
Note: 1/3 octaves are largely a waste of time. This is the 
21st century - FFT is available free on smartphones… 
•Audio Recordings 
Any SLM can be used to produce calibrated audio files 
that can then be analysed by ear and by software 
Play back modified audio to the complainant
www.invc.co.uk 
Source Identification and Ranking 
Identification Techniques 
• run each source separately - measure in far field at reference 
points 
• measure each source close in and predict noise levels (sound 
power and propagation) 
• use narrow band frequency analysis - compare far field and close 
in signatures 
Rank the Sources 
• …by the subjective impact, NOT just dB(A)
www.invc.co.uk 
Cooling Towers
www.invc.co.uk 
Rank Multiple Sources Cooling Towers 
Ranked sources 
• large cooling tower 
• small cooling tower 
• main pumps (5) 
• lift pumps (13) 
Ranked local sources for 
dominant contributor: 
Large cooling tower 
• tower air outlets (3) 
• tower air inlets (3) 
• fan motors
www.invc.co.uk 
Rank Multiple Sources Cooling Towers 
Ranked sources 
tower air outlets (3) 
tower air inlets (3) 
main pumps (5) 
lift pumps (13) 
Conventional: 
3 sets of silencers (outlets) + noise barrier at boundary at c 
£30,000; 56dB(A) 
Detailed Diagnosis 
Modify outlets and inlets, silence main pump cooling fans, local 
screening for lift pumps at c £5000; <50dB(A)
www.invc.co.uk 
Cooling Tower: Untreated / Treated
www.invc.co.uk 
Cooling Tower Pumps: Untreated / Treated
www.invc.co.uk 
Battery Stack Diagnosis
www.invc.co.uk 
Battery Factory Stacks 
Diagnostic measurements 
• synchronise recording time and engineer's watch 
• define shut-down and start-up sequence for stacks 
• engineer notes time of each operation 
• record whole period 
• analyse recording - use timings to identify sources 
Solution 
• purpose designed silencer inserts dropped into 4 of the 5 
stacks 
• 12 - 15 dB(A) reduction in stack noise
www.invc.co.uk 
Press Shop Noise Complaints 
• £12k wasted on factory end wall treatment, 
£65k additional roof improvements planned 
(no guarantee) and £40k+ legal fees spent… 
• 3 presses required treatment - c£12k solved 
problem. 
http://www.invc.co.uk/noise/noise-control/environmental-noise-control/#casestudies
www.invc.co.uk 
Air Handling / Chiller Units 
The Problem 
Several chillers and 2 large AHUs installed at the 
rear of a high tech facility were causing serious 
environmental noise complaints (more than 
10dB(A) above background with tonal content). 
£100k spent on ineffective noise control - one 
chiller fitted with silencers, simple noise barrier 
erected (which also caused air-flow problems) - 
but with no effect on complaints…. 
The Solution 
The primary requirement was to carry out an 
accurate diagnosis that would allow the sources 
to be ranked in terms of their contribution to the 
environmental noise and then to rank the noise 
sources within each of the significant 
contributors. 
http://www.invc.co.uk/noise/noise-control/environmental-noise-control/#casestudies
www.invc.co.uk 
AHU Diagnosis and Noise Control 
Diagnosis 
• 2 existing acoustic louvres on each unit for extract and supply air. 
Detailed noise measurements were carried out inside each 
plenum and outside each louvre over the operating range of the 
unit. 
- top louvre (extract) 4dB(A) noisier 
- poor design due to potential for air recirculation 
Noise Control 
• turn top louvre round (also improve performance) 
• line plenums with acoustic absorbent 
• fit baffle to extract fan outlet to reduce noise transmission down 
into supply plenum and out through louvre 
• plenum lining and baffle reduced noise by 5.5dB(A) 
• total noise reduction just over 10dB(A)
www.invc.co.uk 
Air Handling Unit: Re-directed Extract 
Extract 
Supply
www.invc.co.uk 
Diagnosis Outside Plenums
www.invc.co.uk 
AHU Modifications 
complainants 
before 
after 
extract 
supply 
84dB(A) 
louvres 
80dB(A) filter 
absorbent 
baffle 
78dB(A)
www.invc.co.uk 
Chiller Silencers and Barrier 
Intake and exhaust silencers fitted by supplier. Exhaust silencers have some 
benefit, intakes none as the chiller is open at the far end. The barriers have 
only a small effect for similar reasons.
www.invc.co.uk 
Dry Chiller: Impellor Change 
noisy impellor 
quiet impellor
www.invc.co.uk 
Panel Vibration Reduction 
damped 
undamped 
Total 8dB(A) noise reduction under 
chiller (damping + absorbent)
www.invc.co.uk 
Source Ranking and Target Level 
Overall target at complainant: 40dB(A): (35dB(A) + 35dB(A) + 35dB(A)) 
Eliminate tonal components
www.invc.co.uk 
Chiller Plant Noise Reduction
www.invc.co.uk 
bedroom 
window 
open/shut 
Cooling Tower Tonal Source ID 
cooling towers 1 / 2 at 2m 
grinder 5m
www.invc.co.uk 
Cooling Towers: Detail 
Only 71.3Hz blade pass of fans in tower 1 matches bedroom 
spectrum - grinder and tower 2 are eliminated as sources
www.invc.co.uk 
Remote Control of Noise 
video 
sound 
photos 
email 
-internet 
Specialised analysis 
BPM 
BAT 
Costs 
database 
experience 
@ 
@ 
http://www.invc.co.uk/noise/noise-control/remote-control-of-noise/
www.invc.co.uk 
Remote Control of Noise 
Roof-top fans 
£50k wasted on acoustic lagging – no effect 
Aerodynamic modifications 
135Hz reduced by 17dB 
270Hz reduced by 22dB 
http://www.invc.co.uk/noise/noise-control/remote-control-of-noise/
www.invc.co.uk 
Noise Complaints from Industrial Premises 
Source: National Physical Laboratory
www.invc.co.uk 
Fan Noise Control Options 
Techniques by priority and cost effectiveness…. 
•Control at source 
engineering modifications 
efficiency – lowest fan noise coincides with maximum efficiency 
vibration isolation and vibration damping 
Only if the above are not practical should you consider… 
•Silencing 
•Enclosures 
•Lagging 
•Barriers 
•Building modifications 
Conventionally, these 
high cost techniques 
have been the only 
measures that are 
considered…. 
http://www.invc.co.uk/noise/noise-control/fan-noise-reduction/
www.invc.co.uk 
Innovative Noise Control Technology 
These are some of the innovations we use as part of current best practice 
in environmental noise control. 
• Quiet Fan technology (QFt) 
 typically 10% - 20% of the cost, no effect on fan efficiency 
• Chiller / HVAC noise control 
 <20% of the cost, free cooling unaffected, higher efficiency 
• Fan / combustion stacks 
 retro-fit, low cost, fast 
• Burner / combustion noise 
 source control technology – typically <5% of the cost 
• Acoustic Camouflage 
 psychological electronic silencing
www.invc.co.uk 
London: Office A/C Plant… 
• Chillers on top of high-rise office block caused noise complaints in an 
adjacent street 
• Noise consultancy carried out BS 4142 assessment and 
recommended replacing one of the chillers 
• Chiller replaced at cost of £100k, several dB(A) quieter at 1m 
• Complaints unabated as the noise nuisance was caused by low 
frequency tonal noise from a different chiller… 
http://www.invc.co.uk/noise/noise-control/fan-noise-reduction/#chiller
www.invc.co.uk 
Diageo Chiller 
Cooling tower noise experts report conclusion:- 
• “A “pure tone” is extremely difficult to eradicate as it requires changes 
to the mass being excited and as indicated is a direct result of the 
noise power at a primary frequency being amplified and combined 
with other harmonics across the frequency band. 
• There is no quick fix or simple change that can cure such 
phenomena. In order to cut the generated noise level from this 
cooling tower we believe the only solution is to correct the fault at 
source with a fan change out but while doing so install a low sound 
fan i.e. wide cord, sophisticated profile, larger diameter and run at 
slower speed.” 
• £30,500 plus downtime of several days.
www.invc.co.uk 
Diageo Chiller 
Diagnosis 
•£30k recommendation made with no frequency analysis… 
•Analysis of video soundtrack via email – 10 minutes 
•670Hz tone is gear-mesh frequency of motor pinion 
•Recommended replace gear 
•Whole gearbox replaced <£3,000, downtime c one day 
Video soundtrack analysis
www.invc.co.uk 
Dryer Fan 
The recommendation from the first noise specialist was the following: 
• Replace impeller or whole fan if practicable to prevent tone being 
generated. A cost estimate for a replacement fan and discharge 
silencer was obtained at approximately £100k and would require an 
extended shutdown to install and modify the existing duct-work to suit. 
• Fit attenuators to fan if necessary to reduce noise levels at stack by 5 
- 10 dB. The proposal was to add a top conical section to the stack to 
increase the exit velocity. This was not pursued as it had high 
installation cost as the stack could not self-support the new section. 
http://www.invc.co.uk/noise/noise-control/fan-noise-reduction/
www.invc.co.uk 
Dryer Fan 
Diagnosis 
•£100k recommendation made with no frequency analysis… 
•An internet search by the Precipitates Plant Manager led company to 
approach us about our Quiet Fan technology… 
•The noise control measures reduced the tone by 20dB, cost <£7k and 
paid for themselves in around 9 months as they reduce power 
consumption… 
Noise analysis 
http://www.invc.co.uk/noise/noise-control/fan-noise-reduction/
www.invc.co.uk 
Corrugation Plant 
• Abatement notice - £150k quoted 
for building modification - with no 
guarantee of success. EHO 
suggested our 2nd opinion… 
• Diagnosed corrugator roller tones 
and defined BPM. 
• Reduced tonal content at source 
by 12dB – and eliminated PPE 
requirement – for cost of £25k…
www.invc.co.uk 
Restaurant Fans and Chiller 
Kitchen extract exhaust system and chiller on roof 
65dB(A) outside bathroom window; 33dB(A) in bedroom 
Consultant recommendation: move chiller + build noise barrier; 
expensive silencer in duct
www.invc.co.uk 
Restaurant Fans and Chiller 
Naked chiller Proposed silencer (£400)
www.invc.co.uk 
Restaurant Fans and Chiller 
Bedroom and room 
below chiller 
Chiller tone at 48.5Hz + harmonics 
– previous recommendations 
would not have worked….
www.invc.co.uk 
Chiller Fans 
Low frequency noise 
complaints (48.5Hz) 
Money wasted on 
recommended noise 
barrier… 
Emailed this video. 
Analysed soundtrack to 
reveal tonal content… 
http://www.invc.co.uk/noise/noise-control/fan-noise-reduction/#chiller
www.invc.co.uk 
Chiller Fans 
Aerodynamic modifications reduced 
48.5Hz tone by 13dB and other tones by 
up to 20dB plus improved efficiency… 8 
fans, < £4k 
http://www.invc.co.uk/noise/noise-control/fan-noise-reduction/#chiller
www.invc.co.uk 
Schiller Biomass Power Station Fan 
• 50MW station (largest in USA) 
noise problem: 2 storey ID fan. 
• Conventional silencer had a 
very big impact on efficiency 
• QFt fitted in only 12 hours! 
• 10dB reduction in noise 
• Fan power consumption 
reduced 
• No site visit… 
“…the 3m wide ID combustion 
fan could be heard across the 
river… after installation (only 12 
hours)…10dB drop in noise, 
which is huge…recorded a 
reduction in ID fan power after 
QFt had been installed.” – Jim 
Granger, Senior Engineer 
http://www.invc.co.uk/noise/noise-control/fan-noise-reduction/
www.invc.co.uk 
Scrap Can Extract and Chopper Fans 
modified fan 
Problem 
Occupational + environmental tonal 
noise 
Conventional 
• silencers, lagging and enclosures 
• capital cost > c£35000 + 
maintenance costs 
BPM Engineering 
• internal fan modification reduced 
tones by 23dB and overall noise 
by 22dB(A) 
• cost c £3000 - no maintenance 
costs (lasts the lifetime of the fans 
despite passage of cans) 
http://www.invc.co.uk/noise/noise-control/fan-noise-reduction/
www.invc.co.uk 
Thermal Oxidiser Fans 
New plant – supplier suggested earth berm, enclosures etc 
CMB asked for a 2nd opinion 
BPM – Quiet fan technology, remove “beating”, damper type and location 
changed, small secondary silencers: 15dB(A) reduction >£100k saved and 
more efficient….
www.invc.co.uk 
Axial Vent Fans 
8 off axial vent fans with 8m long silencers several stories up 
112Hz blade pass problem tone reduced by 20dB by fitting invertors to 
change speed slightly to avoid resonant condition. 
http://www.invc.co.uk/noise/noise-control/fan-noise-reduction/#chiller
www.invc.co.uk 
Chiller Farm 
£300k quoted to reduce fan noise - several stories up – loss of free cooling 
Innovative geometries + control systems + control at source 
15dB(A) reduction, no loss of efficiency, c £40k… 
http://www.invc.co.uk/noise/noise-control/fan-noise-reduction/#chiller
www.invc.co.uk 
Yoghurt-Based Noise Control - Boiler Burner 
16dB tonal noise reduction 
http://www.invc.co.uk/noise/noise-control/environmental-noise-control/
www.invc.co.uk 
Cement Works Stack Noise Control 
• Plant update to improve efficiency 
had a disastrous effect on stack 
noise, causing complaints over a 
wide area. 
• Planned conventional silencing 
would have been very costly and 
would have caused unacceptable 
down-time. 
• We designed tuned inserts that 
were installed over a weekend. 
• Noise reduced by 19dB with no 
effect on system efficiency and at 
a small fraction of the cost. 
http://www.invc.co.uk/noise/noise-control/environmental-noise-control/
www.invc.co.uk 
Remote Control of Noise 
BP Refinery: $1.25m conventional silencers: $0.25m via engineering 
– no impact on efficiency, no site visit
www.invc.co.uk 
In Summary 
The “Noise Industry” 
• Generally displays a woeful ignorance of both diagnostic 
techniques and modern noise control methods 
The Victims 
• Thousands of people are therefore needlessly exposed to stressful 
noise from industrial / commercial premises over prolonged periods 
• Many unnecessary deaths consequently (BMJ and WHO reports) 
• Companies waste a fortune on inappropriate mitigation 
The Best Practice to Avoid the Problems 
• The diagnostic procedure that must be followed to evaluate any 
potential noise nuisance problem 
• Case studies illustrating poor practice in attempted mitigation 
(and failed mitigation) of common noise problems 
• Examples of best practice
www.invc.co.uk 
Noise Control Best Practice noise 
QQuueessttiioonnss?? 
PPeetteerr WWiillssoonn MMSScc.. MMIIOOAA 
CCoonnttaacctt uuss ffoorr ffuurrtthheerr iinnffoorrmmaattiioonn 
ccoonnssuulltt@@iinnvvcc..ccoo..uukk ++444411775533 6699888800 
Industrial Noise and Vibration Centre: www.invc.co.uk

Contenu connexe

Similaire à Environmental "noise industry" is not fit for purpose...

exterior_hvac_guidance_sheet
exterior_hvac_guidance_sheetexterior_hvac_guidance_sheet
exterior_hvac_guidance_sheet
timothy park
 
ACA2012 Banff - 01dB DUO at MontrealFBe
ACA2012 Banff - 01dB DUO at MontrealFBeACA2012 Banff - 01dB DUO at MontrealFBe
ACA2012 Banff - 01dB DUO at MontrealFBe
Fred Bouchard
 
Noise pollution
Noise pollutionNoise pollution
Noise pollution
Tej Kiran
 

Similaire à Environmental "noise industry" is not fit for purpose... (20)

ANC Tutorial (2013)
ANC Tutorial (2013)ANC Tutorial (2013)
ANC Tutorial (2013)
 
exterior_hvac_guidance_sheet
exterior_hvac_guidance_sheetexterior_hvac_guidance_sheet
exterior_hvac_guidance_sheet
 
Noise Pollution
Noise PollutionNoise Pollution
Noise Pollution
 
The Fundamentals of HVAC Acoustics
The Fundamentals of HVAC AcousticsThe Fundamentals of HVAC Acoustics
The Fundamentals of HVAC Acoustics
 
Group 18
Group 18Group 18
Group 18
 
OSHA
OSHAOSHA
OSHA
 
Sound Power Basics
Sound Power BasicsSound Power Basics
Sound Power Basics
 
Noise control
Noise controlNoise control
Noise control
 
Symposium Presentation
Symposium PresentationSymposium Presentation
Symposium Presentation
 
Hearing Aid Design for Disabling Hearing Loss
Hearing Aid Design for Disabling Hearing LossHearing Aid Design for Disabling Hearing Loss
Hearing Aid Design for Disabling Hearing Loss
 
Noise Calibration
Noise CalibrationNoise Calibration
Noise Calibration
 
Final Presentation
Final PresentationFinal Presentation
Final Presentation
 
ACA2012 Banff - 01dB DUO at MontrealFBe
ACA2012 Banff - 01dB DUO at MontrealFBeACA2012 Banff - 01dB DUO at MontrealFBe
ACA2012 Banff - 01dB DUO at MontrealFBe
 
Noise Control of Vacuum Cleaners
Noise Control of Vacuum CleanersNoise Control of Vacuum Cleaners
Noise Control of Vacuum Cleaners
 
Method statement to measure noise level by eng. juma yousef juma saleh- getco
Method statement to measure noise level by eng. juma yousef juma saleh- getcoMethod statement to measure noise level by eng. juma yousef juma saleh- getco
Method statement to measure noise level by eng. juma yousef juma saleh- getco
 
Noise pollution
Noise pollutionNoise pollution
Noise pollution
 
Introduction to Industrial Noise Control
Introduction to Industrial Noise ControlIntroduction to Industrial Noise Control
Introduction to Industrial Noise Control
 
Noise pollution
Noise pollutionNoise pollution
Noise pollution
 
Audio_Overview.pptx
Audio_Overview.pptxAudio_Overview.pptx
Audio_Overview.pptx
 
Active Noise Cancellation
Active Noise Cancellation Active Noise Cancellation
Active Noise Cancellation
 

Dernier

Green Marketing
Green MarketingGreen Marketing
Green Marketing
Dr. Salem Baidas
 
Call Girls In Bloom Boutique | GK-1 ☎ 9990224454 High Class Delhi NCR 24 Hour...
Call Girls In Bloom Boutique | GK-1 ☎ 9990224454 High Class Delhi NCR 24 Hour...Call Girls In Bloom Boutique | GK-1 ☎ 9990224454 High Class Delhi NCR 24 Hour...
Call Girls In Bloom Boutique | GK-1 ☎ 9990224454 High Class Delhi NCR 24 Hour...
rajputriyana310
 

Dernier (20)

RATING SYSTEMS- IGBC, GRIHA, LEED--.pptx
RATING  SYSTEMS- IGBC, GRIHA, LEED--.pptxRATING  SYSTEMS- IGBC, GRIHA, LEED--.pptx
RATING SYSTEMS- IGBC, GRIHA, LEED--.pptx
 
Call Girls Talegaon Dabhade Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Talegaon Dabhade Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Talegaon Dabhade Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Talegaon Dabhade Call Me 7737669865 Budget Friendly No Advance Boo...
 
Book Sex Workers Available Pune Call Girls Khadki 6297143586 Call Hot Indian...
Book Sex Workers Available Pune Call Girls Khadki  6297143586 Call Hot Indian...Book Sex Workers Available Pune Call Girls Khadki  6297143586 Call Hot Indian...
Book Sex Workers Available Pune Call Girls Khadki 6297143586 Call Hot Indian...
 
Green Marketing
Green MarketingGreen Marketing
Green Marketing
 
CSR_Module5_Green Earth Initiative, Tree Planting Day
CSR_Module5_Green Earth Initiative, Tree Planting DayCSR_Module5_Green Earth Initiative, Tree Planting Day
CSR_Module5_Green Earth Initiative, Tree Planting Day
 
Alandi Road ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready ...
Alandi Road ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready ...Alandi Road ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready ...
Alandi Road ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready ...
 
Kondhwa ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
Kondhwa ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...Kondhwa ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...
Kondhwa ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
 
VVIP Pune Call Girls Koregaon Park (7001035870) Pune Escorts Nearby with Comp...
VVIP Pune Call Girls Koregaon Park (7001035870) Pune Escorts Nearby with Comp...VVIP Pune Call Girls Koregaon Park (7001035870) Pune Escorts Nearby with Comp...
VVIP Pune Call Girls Koregaon Park (7001035870) Pune Escorts Nearby with Comp...
 
Call Girls Jejuri Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Jejuri Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Jejuri Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Jejuri Call Me 7737669865 Budget Friendly No Advance Booking
 
Verified Trusted Kalyani Nagar Call Girls 8005736733 𝐈𝐍𝐃𝐄𝐏𝐄𝐍𝐃𝐄𝐍𝐓 Call 𝐆𝐈𝐑𝐋 𝐕...
Verified Trusted Kalyani Nagar Call Girls  8005736733 𝐈𝐍𝐃𝐄𝐏𝐄𝐍𝐃𝐄𝐍𝐓 Call 𝐆𝐈𝐑𝐋 𝐕...Verified Trusted Kalyani Nagar Call Girls  8005736733 𝐈𝐍𝐃𝐄𝐏𝐄𝐍𝐃𝐄𝐍𝐓 Call 𝐆𝐈𝐑𝐋 𝐕...
Verified Trusted Kalyani Nagar Call Girls 8005736733 𝐈𝐍𝐃𝐄𝐏𝐄𝐍𝐃𝐄𝐍𝐓 Call 𝐆𝐈𝐑𝐋 𝐕...
 
The Most Attractive Pune Call Girls Shirwal 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Shirwal 8250192130 Will You Miss This Cha...The Most Attractive Pune Call Girls Shirwal 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Shirwal 8250192130 Will You Miss This Cha...
 
Booking open Available Pune Call Girls Yewalewadi 6297143586 Call Hot Indian...
Booking open Available Pune Call Girls Yewalewadi  6297143586 Call Hot Indian...Booking open Available Pune Call Girls Yewalewadi  6297143586 Call Hot Indian...
Booking open Available Pune Call Girls Yewalewadi 6297143586 Call Hot Indian...
 
Call Girls Magarpatta Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Magarpatta Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Magarpatta Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Magarpatta Call Me 7737669865 Budget Friendly No Advance Booking
 
VIP Model Call Girls Hadapsar ( Pune ) Call ON 8005736733 Starting From 5K to...
VIP Model Call Girls Hadapsar ( Pune ) Call ON 8005736733 Starting From 5K to...VIP Model Call Girls Hadapsar ( Pune ) Call ON 8005736733 Starting From 5K to...
VIP Model Call Girls Hadapsar ( Pune ) Call ON 8005736733 Starting From 5K to...
 
Book Sex Workers Available Pune Call Girls Kondhwa 6297143586 Call Hot India...
Book Sex Workers Available Pune Call Girls Kondhwa  6297143586 Call Hot India...Book Sex Workers Available Pune Call Girls Kondhwa  6297143586 Call Hot India...
Book Sex Workers Available Pune Call Girls Kondhwa 6297143586 Call Hot India...
 
VIP Model Call Girls Chakan ( Pune ) Call ON 8005736733 Starting From 5K to 2...
VIP Model Call Girls Chakan ( Pune ) Call ON 8005736733 Starting From 5K to 2...VIP Model Call Girls Chakan ( Pune ) Call ON 8005736733 Starting From 5K to 2...
VIP Model Call Girls Chakan ( Pune ) Call ON 8005736733 Starting From 5K to 2...
 
Call Girls In Bloom Boutique | GK-1 ☎ 9990224454 High Class Delhi NCR 24 Hour...
Call Girls In Bloom Boutique | GK-1 ☎ 9990224454 High Class Delhi NCR 24 Hour...Call Girls In Bloom Boutique | GK-1 ☎ 9990224454 High Class Delhi NCR 24 Hour...
Call Girls In Bloom Boutique | GK-1 ☎ 9990224454 High Class Delhi NCR 24 Hour...
 
Call Girls Service Pune ₹7.5k Pick Up & Drop With Cash Payment 8005736733 Cal...
Call Girls Service Pune ₹7.5k Pick Up & Drop With Cash Payment 8005736733 Cal...Call Girls Service Pune ₹7.5k Pick Up & Drop With Cash Payment 8005736733 Cal...
Call Girls Service Pune ₹7.5k Pick Up & Drop With Cash Payment 8005736733 Cal...
 
Call Girls in Sakinaka Agency, { 9892124323 } Mumbai Vashi Call Girls Serivce...
Call Girls in Sakinaka Agency, { 9892124323 } Mumbai Vashi Call Girls Serivce...Call Girls in Sakinaka Agency, { 9892124323 } Mumbai Vashi Call Girls Serivce...
Call Girls in Sakinaka Agency, { 9892124323 } Mumbai Vashi Call Girls Serivce...
 
VVIP Pune Call Girls Wagholi WhatSapp Number 8005736733 With Elite Staff And ...
VVIP Pune Call Girls Wagholi WhatSapp Number 8005736733 With Elite Staff And ...VVIP Pune Call Girls Wagholi WhatSapp Number 8005736733 With Elite Staff And ...
VVIP Pune Call Girls Wagholi WhatSapp Number 8005736733 With Elite Staff And ...
 

Environmental "noise industry" is not fit for purpose...

  • 1. www.invc.co.uk Noise Control Best Practice noise TThhee EEnnvviirroonnmmeennttaall NNooiissee IInndduussttrryy iiss NNoott FFiitt ffoorr PPuurrppoossee…… PPeetteerr WWiillssoonn MMSScc.. MMIIOOAA Industrial Noise and Vibration Centre: www.invc.co.uk
  • 2. www.invc.co.uk In Summary The “Noise Industry” • Generally displays a woeful ignorance of both diagnostic techniques and modern noise control methods The Victims • Thousands of people are therefore needlessly exposed to stressful noise from industrial / commercial premises over prolonged periods • Many unnecessary deaths consequently (BMJ and WHO reports) • Companies waste a fortune on inappropriate mitigation The Best Practice to Avoid the Problems • The diagnostic procedure that must be followed to evaluate any potential noise nuisance problem • Case studies illustrating poor practice in attempted mitigation (and failed mitigation) of common noise problems • Examples of best practice
  • 3. www.invc.co.uk Noise Kills… WHO Report: 2011 • Europe: c3% of deaths from heart attacks is attributable to long term exposure to (mainly nighttime) environmental noise • 2% of the population suffer from severe sleep disturbance • 15% suffer from serious annoyance • UK noise complaints increased by x5 over the last 20 years • Learning abilities of children badly affected BMJ Report: 2013 • Environmental noise increases the risk of stroke and coronary heart disease due to raised blood pressure and hypertension • Near Heathrow, 24% increased hospital admissions due to stroke; 21% increase due to coronary heart disease; 14% increase for cardiovascular disease cf low noise areas All dB(A) based – but many noise issues are low frequency, so these figures seriously underestimate the problem…
  • 4. www.invc.co.uk BS 4142 – technically… BS 4142 is almost ubiquitous, largely because it exists… However, it is often (badly) applied to situations where it is not suitable. • BS 4142 is supposed to assess the likelihood of complaints from people inside a building by measuring dB(A) outside • inside rooms, the T.L. of windows shapes the spectrum, reducing mid and high frequency components - almost un-'A' weighting the sound • does not work well for noise containing low frequencies • 5dB(A) correction for noise with tones • tonal noise at 5dB(A) below non-tonal noise should be equally disturbing • should not be used where background noise levels are very low (<30dB(A))
  • 5. www.invc.co.uk Environmental Noise Control is .... …not just about the overall level… • Effective noise control must be based on an accurate diagnosis that relates noise features to subjective impact, not just on assumptions about overall dB(A). • Although dB(A) may also be an additional planning / specification requirement, this is often a completely separate issue. • Noise control is an engineering problem that should be solved by engineering means at source wherever practical. • All the options must be considered, not just the high cost conventional palliatives of barriers, enclosures and silencers. http://www.invc.co.uk/noise/noise-control/environmental-noise-control/
  • 6. www.invc.co.uk Attitude, Attitude, Attitude - Placebo Silencers
  • 7. www.invc.co.uk Best Practice Elements • Attitude • Diagnosis - understand the cause of the subjective problem  based on detailed diagnosis, objective evaluation linking noise features to complaints – temporal and tonal components  link problem noise features to specific mechanical / aerodynamic plant elements. • Assess the Noise Control Options  based on current best practice. The majority of noise control recommendations that we see are either not fit for purpose or are far more costly than necessary. • Recommend / Implement Best Practice Noise Control Option  typically reduces noise control costs by 50% - 110%!  reduces the time required to solve problems (often from years to weeks)
  • 8. www.invc.co.uk Diagnosis, Diagnosis, Diagnosis… You’re just guessing… The approach taken to mitigate noise problems is often based on guesswork. There should be no guesswork involved. •Temporal Diagnosis Events, intermittency, turn plant on and off, variation over time… •Frequency Content Broadband: octaves Tones: narrow band frequency analysis Note: 1/3 octaves are largely a waste of time. This is the 21st century - FFT is available free on smartphones… •Audio Recordings Any SLM can be used to produce calibrated audio files that can then be analysed by ear and by software Play back modified audio to the complainant
  • 9. www.invc.co.uk Source Identification and Ranking Identification Techniques • run each source separately - measure in far field at reference points • measure each source close in and predict noise levels (sound power and propagation) • use narrow band frequency analysis - compare far field and close in signatures Rank the Sources • …by the subjective impact, NOT just dB(A)
  • 11. www.invc.co.uk Rank Multiple Sources Cooling Towers Ranked sources • large cooling tower • small cooling tower • main pumps (5) • lift pumps (13) Ranked local sources for dominant contributor: Large cooling tower • tower air outlets (3) • tower air inlets (3) • fan motors
  • 12. www.invc.co.uk Rank Multiple Sources Cooling Towers Ranked sources tower air outlets (3) tower air inlets (3) main pumps (5) lift pumps (13) Conventional: 3 sets of silencers (outlets) + noise barrier at boundary at c £30,000; 56dB(A) Detailed Diagnosis Modify outlets and inlets, silence main pump cooling fans, local screening for lift pumps at c £5000; <50dB(A)
  • 13. www.invc.co.uk Cooling Tower: Untreated / Treated
  • 14. www.invc.co.uk Cooling Tower Pumps: Untreated / Treated
  • 16. www.invc.co.uk Battery Factory Stacks Diagnostic measurements • synchronise recording time and engineer's watch • define shut-down and start-up sequence for stacks • engineer notes time of each operation • record whole period • analyse recording - use timings to identify sources Solution • purpose designed silencer inserts dropped into 4 of the 5 stacks • 12 - 15 dB(A) reduction in stack noise
  • 17. www.invc.co.uk Press Shop Noise Complaints • £12k wasted on factory end wall treatment, £65k additional roof improvements planned (no guarantee) and £40k+ legal fees spent… • 3 presses required treatment - c£12k solved problem. http://www.invc.co.uk/noise/noise-control/environmental-noise-control/#casestudies
  • 18. www.invc.co.uk Air Handling / Chiller Units The Problem Several chillers and 2 large AHUs installed at the rear of a high tech facility were causing serious environmental noise complaints (more than 10dB(A) above background with tonal content). £100k spent on ineffective noise control - one chiller fitted with silencers, simple noise barrier erected (which also caused air-flow problems) - but with no effect on complaints…. The Solution The primary requirement was to carry out an accurate diagnosis that would allow the sources to be ranked in terms of their contribution to the environmental noise and then to rank the noise sources within each of the significant contributors. http://www.invc.co.uk/noise/noise-control/environmental-noise-control/#casestudies
  • 19. www.invc.co.uk AHU Diagnosis and Noise Control Diagnosis • 2 existing acoustic louvres on each unit for extract and supply air. Detailed noise measurements were carried out inside each plenum and outside each louvre over the operating range of the unit. - top louvre (extract) 4dB(A) noisier - poor design due to potential for air recirculation Noise Control • turn top louvre round (also improve performance) • line plenums with acoustic absorbent • fit baffle to extract fan outlet to reduce noise transmission down into supply plenum and out through louvre • plenum lining and baffle reduced noise by 5.5dB(A) • total noise reduction just over 10dB(A)
  • 20. www.invc.co.uk Air Handling Unit: Re-directed Extract Extract Supply
  • 22. www.invc.co.uk AHU Modifications complainants before after extract supply 84dB(A) louvres 80dB(A) filter absorbent baffle 78dB(A)
  • 23. www.invc.co.uk Chiller Silencers and Barrier Intake and exhaust silencers fitted by supplier. Exhaust silencers have some benefit, intakes none as the chiller is open at the far end. The barriers have only a small effect for similar reasons.
  • 24. www.invc.co.uk Dry Chiller: Impellor Change noisy impellor quiet impellor
  • 25. www.invc.co.uk Panel Vibration Reduction damped undamped Total 8dB(A) noise reduction under chiller (damping + absorbent)
  • 26. www.invc.co.uk Source Ranking and Target Level Overall target at complainant: 40dB(A): (35dB(A) + 35dB(A) + 35dB(A)) Eliminate tonal components
  • 27. www.invc.co.uk Chiller Plant Noise Reduction
  • 28. www.invc.co.uk bedroom window open/shut Cooling Tower Tonal Source ID cooling towers 1 / 2 at 2m grinder 5m
  • 29. www.invc.co.uk Cooling Towers: Detail Only 71.3Hz blade pass of fans in tower 1 matches bedroom spectrum - grinder and tower 2 are eliminated as sources
  • 30. www.invc.co.uk Remote Control of Noise video sound photos email -internet Specialised analysis BPM BAT Costs database experience @ @ http://www.invc.co.uk/noise/noise-control/remote-control-of-noise/
  • 31. www.invc.co.uk Remote Control of Noise Roof-top fans £50k wasted on acoustic lagging – no effect Aerodynamic modifications 135Hz reduced by 17dB 270Hz reduced by 22dB http://www.invc.co.uk/noise/noise-control/remote-control-of-noise/
  • 32. www.invc.co.uk Noise Complaints from Industrial Premises Source: National Physical Laboratory
  • 33. www.invc.co.uk Fan Noise Control Options Techniques by priority and cost effectiveness…. •Control at source engineering modifications efficiency – lowest fan noise coincides with maximum efficiency vibration isolation and vibration damping Only if the above are not practical should you consider… •Silencing •Enclosures •Lagging •Barriers •Building modifications Conventionally, these high cost techniques have been the only measures that are considered…. http://www.invc.co.uk/noise/noise-control/fan-noise-reduction/
  • 34. www.invc.co.uk Innovative Noise Control Technology These are some of the innovations we use as part of current best practice in environmental noise control. • Quiet Fan technology (QFt)  typically 10% - 20% of the cost, no effect on fan efficiency • Chiller / HVAC noise control  <20% of the cost, free cooling unaffected, higher efficiency • Fan / combustion stacks  retro-fit, low cost, fast • Burner / combustion noise  source control technology – typically <5% of the cost • Acoustic Camouflage  psychological electronic silencing
  • 35. www.invc.co.uk London: Office A/C Plant… • Chillers on top of high-rise office block caused noise complaints in an adjacent street • Noise consultancy carried out BS 4142 assessment and recommended replacing one of the chillers • Chiller replaced at cost of £100k, several dB(A) quieter at 1m • Complaints unabated as the noise nuisance was caused by low frequency tonal noise from a different chiller… http://www.invc.co.uk/noise/noise-control/fan-noise-reduction/#chiller
  • 36. www.invc.co.uk Diageo Chiller Cooling tower noise experts report conclusion:- • “A “pure tone” is extremely difficult to eradicate as it requires changes to the mass being excited and as indicated is a direct result of the noise power at a primary frequency being amplified and combined with other harmonics across the frequency band. • There is no quick fix or simple change that can cure such phenomena. In order to cut the generated noise level from this cooling tower we believe the only solution is to correct the fault at source with a fan change out but while doing so install a low sound fan i.e. wide cord, sophisticated profile, larger diameter and run at slower speed.” • £30,500 plus downtime of several days.
  • 37. www.invc.co.uk Diageo Chiller Diagnosis •£30k recommendation made with no frequency analysis… •Analysis of video soundtrack via email – 10 minutes •670Hz tone is gear-mesh frequency of motor pinion •Recommended replace gear •Whole gearbox replaced <£3,000, downtime c one day Video soundtrack analysis
  • 38. www.invc.co.uk Dryer Fan The recommendation from the first noise specialist was the following: • Replace impeller or whole fan if practicable to prevent tone being generated. A cost estimate for a replacement fan and discharge silencer was obtained at approximately £100k and would require an extended shutdown to install and modify the existing duct-work to suit. • Fit attenuators to fan if necessary to reduce noise levels at stack by 5 - 10 dB. The proposal was to add a top conical section to the stack to increase the exit velocity. This was not pursued as it had high installation cost as the stack could not self-support the new section. http://www.invc.co.uk/noise/noise-control/fan-noise-reduction/
  • 39. www.invc.co.uk Dryer Fan Diagnosis •£100k recommendation made with no frequency analysis… •An internet search by the Precipitates Plant Manager led company to approach us about our Quiet Fan technology… •The noise control measures reduced the tone by 20dB, cost <£7k and paid for themselves in around 9 months as they reduce power consumption… Noise analysis http://www.invc.co.uk/noise/noise-control/fan-noise-reduction/
  • 40. www.invc.co.uk Corrugation Plant • Abatement notice - £150k quoted for building modification - with no guarantee of success. EHO suggested our 2nd opinion… • Diagnosed corrugator roller tones and defined BPM. • Reduced tonal content at source by 12dB – and eliminated PPE requirement – for cost of £25k…
  • 41. www.invc.co.uk Restaurant Fans and Chiller Kitchen extract exhaust system and chiller on roof 65dB(A) outside bathroom window; 33dB(A) in bedroom Consultant recommendation: move chiller + build noise barrier; expensive silencer in duct
  • 42. www.invc.co.uk Restaurant Fans and Chiller Naked chiller Proposed silencer (£400)
  • 43. www.invc.co.uk Restaurant Fans and Chiller Bedroom and room below chiller Chiller tone at 48.5Hz + harmonics – previous recommendations would not have worked….
  • 44. www.invc.co.uk Chiller Fans Low frequency noise complaints (48.5Hz) Money wasted on recommended noise barrier… Emailed this video. Analysed soundtrack to reveal tonal content… http://www.invc.co.uk/noise/noise-control/fan-noise-reduction/#chiller
  • 45. www.invc.co.uk Chiller Fans Aerodynamic modifications reduced 48.5Hz tone by 13dB and other tones by up to 20dB plus improved efficiency… 8 fans, < £4k http://www.invc.co.uk/noise/noise-control/fan-noise-reduction/#chiller
  • 46. www.invc.co.uk Schiller Biomass Power Station Fan • 50MW station (largest in USA) noise problem: 2 storey ID fan. • Conventional silencer had a very big impact on efficiency • QFt fitted in only 12 hours! • 10dB reduction in noise • Fan power consumption reduced • No site visit… “…the 3m wide ID combustion fan could be heard across the river… after installation (only 12 hours)…10dB drop in noise, which is huge…recorded a reduction in ID fan power after QFt had been installed.” – Jim Granger, Senior Engineer http://www.invc.co.uk/noise/noise-control/fan-noise-reduction/
  • 47. www.invc.co.uk Scrap Can Extract and Chopper Fans modified fan Problem Occupational + environmental tonal noise Conventional • silencers, lagging and enclosures • capital cost > c£35000 + maintenance costs BPM Engineering • internal fan modification reduced tones by 23dB and overall noise by 22dB(A) • cost c £3000 - no maintenance costs (lasts the lifetime of the fans despite passage of cans) http://www.invc.co.uk/noise/noise-control/fan-noise-reduction/
  • 48. www.invc.co.uk Thermal Oxidiser Fans New plant – supplier suggested earth berm, enclosures etc CMB asked for a 2nd opinion BPM – Quiet fan technology, remove “beating”, damper type and location changed, small secondary silencers: 15dB(A) reduction >£100k saved and more efficient….
  • 49. www.invc.co.uk Axial Vent Fans 8 off axial vent fans with 8m long silencers several stories up 112Hz blade pass problem tone reduced by 20dB by fitting invertors to change speed slightly to avoid resonant condition. http://www.invc.co.uk/noise/noise-control/fan-noise-reduction/#chiller
  • 50. www.invc.co.uk Chiller Farm £300k quoted to reduce fan noise - several stories up – loss of free cooling Innovative geometries + control systems + control at source 15dB(A) reduction, no loss of efficiency, c £40k… http://www.invc.co.uk/noise/noise-control/fan-noise-reduction/#chiller
  • 51. www.invc.co.uk Yoghurt-Based Noise Control - Boiler Burner 16dB tonal noise reduction http://www.invc.co.uk/noise/noise-control/environmental-noise-control/
  • 52. www.invc.co.uk Cement Works Stack Noise Control • Plant update to improve efficiency had a disastrous effect on stack noise, causing complaints over a wide area. • Planned conventional silencing would have been very costly and would have caused unacceptable down-time. • We designed tuned inserts that were installed over a weekend. • Noise reduced by 19dB with no effect on system efficiency and at a small fraction of the cost. http://www.invc.co.uk/noise/noise-control/environmental-noise-control/
  • 53. www.invc.co.uk Remote Control of Noise BP Refinery: $1.25m conventional silencers: $0.25m via engineering – no impact on efficiency, no site visit
  • 54. www.invc.co.uk In Summary The “Noise Industry” • Generally displays a woeful ignorance of both diagnostic techniques and modern noise control methods The Victims • Thousands of people are therefore needlessly exposed to stressful noise from industrial / commercial premises over prolonged periods • Many unnecessary deaths consequently (BMJ and WHO reports) • Companies waste a fortune on inappropriate mitigation The Best Practice to Avoid the Problems • The diagnostic procedure that must be followed to evaluate any potential noise nuisance problem • Case studies illustrating poor practice in attempted mitigation (and failed mitigation) of common noise problems • Examples of best practice
  • 55. www.invc.co.uk Noise Control Best Practice noise QQuueessttiioonnss?? PPeetteerr WWiillssoonn MMSScc.. MMIIOOAA CCoonnttaacctt uuss ffoorr ffuurrtthheerr iinnffoorrmmaattiioonn ccoonnssuulltt@@iinnvvcc..ccoo..uukk ++444411775533 6699888800 Industrial Noise and Vibration Centre: www.invc.co.uk