4. Siemens CT Vision
Siemens CT Vision
Today’s reality product development, and design, relies
upon the advice and recommendations
The justification for the existence of the of external medical experts to determine
entire medical industry is, of course, our focus – and this focus has been on
better healthcare for all patients. But the the needs and demands of our end users.
realities of clinical practice often make this Over the years, this focus has been fine-
simple-to-understand goal quite difficult tuned in four key areas:
to realize: stay within budgets, reduce • to lead technological and medical
hospital stays, speed up time to diagnosis, advancement
and deal with personnel issues, while • to maximize workflow efficiency
maintaining high clinical standards and • to make state-of-the-art CT affordable
volume/throughput. At the same time, • to set the standard in customer care.
patients demand better and faster results.
Our vision
Our approach
As a partner of our customers, we create
In order to meet our share of responsibility CT innovations, that lift clinical practice
in addressing these challenges, Siemens, to a next level of excellence and enable
from the earliest stages of research, wide access to better patient care. We
4
5. believe that even the farthest technical Patient-centric productivity Siemens CT Vision 4
horizons are temporary and can be
surpassed with consistent dedication Now, we are again setting the bar higher SOMATOM Definition Flash 8
to improved healthcare. This visionary with FAST CARE technologies. Fully
approach, backed up by the, by far, largest Assisting Scanner Technologies (FAST) Split-Second Scanning 10
R&D budgets in the healthcare industry, make complex procedures faster, more Defining Low Dose CT 22
has made Siemens the undisputed inno- intuitive, and more reproducible than ever. Dual Source DE for all Patients 34
vation leader in CT over the last 35 years. For example, preparing an anatomically
And our ambitious global team continues correct reconstruction of the whole spine Customer Care 46
to set the trend in an always changing now takes only 30 seconds, compared to
environment, providing Answers for Life. 30 minutes when doing it manually. At the Configuration Overview 48
same time, our Combined Applications to
Leading patient care Reduce Exposure (CARE) are now stream-
lined to make dose reduction easier for all
Today, more than 700 institutions examinations while providing a transparent
worldwide have already taken this dose-saving management. FAST CARE
opportunity to improve patient healthcare delivers a new dimension in clinical
and push their clinical boundaries to a efficiency and patient care. We call it:
higher level utilizing Dual Source CT. patient-centric productivity.
5
8. Flash speed.
Lowest dose.
SOMATOM Definition Flash
Flash speed children, patients who cannot hold their complex CT procedures: the scanning
breath for long), thus causing no process becomes more intuitive, more
The SOMATOM® Definition Flash opens a time-consuming interruptions in your daily automated, and results become more
door to new levels of patient friendliness practice. And now Siemens is once again reproducible. Integrating the capabilities
with the speed to cover the entire thorax redefining speed: the new SOMATOM of the recently developed syngo®.via*
in less than a second – if necessary even Definition Flash, with the new FAST CARE image management platform with its
without a breath hold. A whole-body scan technology platform, allows you to many powerful automated preprocessing
requires only five seconds, while for maximize clinical outcomes – meaning steps and intuitive user interface, the
perfusion or dynamic vascular imaging you will have the best possible clinical complete examination – from scan
long-range scans become routine and results, but with significantly less preparation, scanning, reconstruction, and
pediatric scans become sub-second resources bound to the CT system. The data assessment – is streamlined, leading
procedures. Your patients will be off the ultimate goal is to provide you with more to a fast and reliable diagnosis with less
table faster than ever before – with time for patients and diagnosis – in effect, patient burden. Ultimately, the combination
positive feelings about their scan patient-centric productivity. Our Fully of highest image quality and highest
experience. Flash is also the solution for Assisting Scanner Technologies (FAST) on patient-centric productivity is the lever to
scanning your most difficult patients the new SOMATOM Definition Flash maximizing your clinical outcomes.
(i.e. obese and trauma patients, restless simplify typically time-consuming and
8
9. Lowest dose With the new SOMATOM Definition Flash Add SAFIRE**, the first, raw-data-based
with FAST CARE, Siemens introduces iterative reconstruction, and define low
Maybe even more important – and several innovative Combined Applications dose for all body regions to take best care
impressive – is the incredible reduction in to Reduce Exposure (CARE). CARE kV, for of your patients’ well-being.
dose for all scans, resulting, e.g. in dose instance, is the industry’s first tool that
down to sub-mSv for cardiac imaging. automatically solves the complex equation
Now in its second generation, Dual Energy for optimal image quality at lowest
automatically provides a second contrast possible dose for each individual CT exam
for the best possible diagnosis and added while considering tube voltage, tube
diagnostic confidence so that each scan current, and contrast changes at different *syngo.via can be used as a stand-alone device
can now become a Dual Energy scan. At voltages and attenuation. This allows you or together with a variety of syngo.via-based
the same time, X-CARE protects individual to benefit from the industry’s widest tube software options, which are medical devices in
their own rights.
organs and the most radiation-sensitive voltage range – not only 140 kV for
body regions – for example, female bariatric imaging but now, if necessary,
**The information about this product is being
breasts – by accurately and efficiently also down to 70 kV for new safety and provided for planning purposes.
minimizing exposure while preserving image quality standards in pediatric The product is pending 510(k) review, and is
image quality. imaging. not yet commercially available in the U.S.
9
11. Split-Second
Scanning
How often has your daily practice been interrupted or delayed by fragile,
sick, or traumatic patients who either cannot hold their breath or become
impatient during regular scan procedures? Finding a solution to these
hindrances is what has motivated us to design the world’s fastest CT, by
utilizing Dual Source for Flash-like scan speeds of up to 458 mm/s.
With Flash Spiral scanning, holding breath and motion lose their
significance, making the SOMATOM Definition Flash the optimal patient-
friendly CT. We introduce you to the new, cutting-edge of FAST CARE
technology that raises the standard of your patient-centric productivity,
e.g. through FAST Cardio Wizard, that breaks down the restrictions of
previous CT scanning in cardiology. Today, split-second scanning is
proving its value in actual practice. Emergency department trauma scans
of an entire body in less than five seconds with dose usually under 5 mSv
have also been made possible by the Flash’s speed. Now, with the help of
the FAST Spine feature, making the preparation of complex vertebrae
and disc reconstructions a matter of one click and 30 seconds, we take
trauma imaging and neurological CT examinations to the next efficiency
level for earlier and more accurately targeted treatment.
11
12. Introduction
Split-Second Scanning
< 1 sec
Body imaging in adult and Definition Flash with FAST CARE now
pediatric patients offers Siemens’ unique FAST (Fully
Assisting Scanner Technologies) platform
Scanning an entire thorax in only to support you in finding and applying the
0.6 seconds for motion-artifact-free ideal settings for every individual
studies that revolutionizes triple-rule-out examination to get to a safe, sound, and
Tube 1 Tube 2 Vol
protocols. The scan speed is fast enough sustainable diagnosis.
Sub-second thorax scan for triple-rule-out and a dose to image the thorax without any breath
below 5 mSv. hold and also produces crystal clear Cardiac imaging in a quarter
imaging of the coronary arteries, thus of a heartbeat
< 1 sec routinely enabling sub-second triple-rule-
out with less than 5 mSv dose. The system’s unique split-second scanning
capability allows scanning the heart in
Bringing this scan speed to imaging only 250 ms, a quarter of a heartbeat.
children makes sedation a thing of the Together with its highest temporal
past. Now Flash Spiral scans are resolution of 75 ms, available in all cardiac
consistently fast enough to produce sharp scan modes, it freezes any cardiac motion
Tube 1 Tube 2 Vol
pediatric images without sedation. This safely, irrespective of the heart rate.
Sub-second pediatric scan without the need for sedation shortens prep time, eliminates repeating
or anesthesia. scans due to motion, and reduces risk as Fastest scanning preparation
well as anxiety.
< 4 sec The challenge for each CT scan is to find
Fastest emergency CT and apply the ideal settings for every
individual patient, but at the same time
For several years now, CT has been the achieve a high degree of reproducibility.
ideal modality for trauma cases. However, Now, with FAST, scan and recon planning
in the most severe cases the time required can become as fast and easy as just
to produce useful images often placed the one click.
Tube 1 Tube 2 Vol
patient at risk. With Flash speed, scan time
Whole body imaging in less than 4 seconds without is no longer an issue. The new SOMATOM
motion artifacts.
12 Split-second scanning
13. Automated scan and recon possible. FAST Cardio Wizard helps you
planning achieve high-quality clinical outcomes in
every situation. Flash Spiral scanning –
Decisive for the ideal settings for scan,
reconstruction, and image evaluation are Ready for review in one click no breath hold required
the organs and body regions. Based on the
respective organ, the chosen examination FAST Spine, another prominent feature
Sharp coronaries at all heart rates
type, and, at the end, also expected of the FAST technology, enhances rapid – even without beta-blockers
images, in-depth knowledge of the trauma and neuro imaging, saving up to
appropriate system settings is normally 30 minutes with a single click compared Pediatric scans without sedation
required. Imagine the time the system to conventional workflows. Again easing,
can save you by automatically planning accelerating, and standardizing the Whole body trauma scan < 4 sec
the subsequent reconstruction fields in workflow in CT scanning.
a whole body trauma. The SOMATOM Both guided and standardized
Definition Flash with FAST and syngo.via syngo.via-based diagnosis cardiac workflow
now automatically assist you in solving
this challenge, making possible even Let us look at only one example of more
shorter time to diagnosis and more than 17 functions that syngo.via, the
Accurate spine recons with
interaction with patients. outstanding multimodality imaging just a single click
platform, performs: a triple-rule-out
All heart rates, all patients assessment in less than four minutes Immediate, organ-based scan
and automatically (at no click), coronal
Not only does the selection of the and sagittal images for your referring
planning
appropriate scan mode for imaging every physicians located anywhere in your
cardiac patient demand expertise, but also clinical network. The reading physician
the preparation for image evaluation is can immediately start with the evaluation
anything but trivial. It is important that of the case without wasting efforts in case
you feel safe in having done everything in preparation.
order to achieve the best clinical outcome
13
14. How it works
Flash Spiral
Even the most advanced single-source CTs The SOMATOM Definition Flash guarantees
are limited in their scan speed by the fast and accurate ED imaging by putting
maximum table feed that can be used and you in the position to achieve earlier and
still allow the acquisition of contiguous more accurately targeted treatment
data. The SOMATOM Definition Flash decisions that positively affect the patients
breaks through this barrier primarily by 30-day adverse event rate and reduce
simultaneously integrating data from a repeated visits.(2)
second source during the scan. By
combining this Dual Source technology Revolutionizing the
with fastest available hardware triple-rule-out
components, including a gantry that
rotates at 0.28 seconds, a patient table In case of acute chest pain, scanning
that can handle immense table feeds, and with the SOMATOM Definition Flash
ultra-fast data transmission technology, significantly saves time because it is now
makes possible the fastest scan mode in possible to assess pulmonary arteries,
CT history. The result is an unprecedented coronary arteries, and the aorta in a single
scan speed of up to 458 mm/s, fast split-second scan. Scientific validation in
enough to scan an entire adult patient large cohorts demonstrate impressive
in less than four 4 seconds. results. Due to the SOMATOM Definition
Flash’s split-second scanning capabilities
Increased patient friendliness physicians obtain “motion-artifact-free
and accurate visualization” in these
Patients who cannot hold their breath or challenging examinations “at a very low
suffer from shortness of breath, patients radiation exposure.”(2) Mean scan times are Single-source CT requires slower table feeds to prevent
who are restless or impatient, who are 0.7 seconds while a radiation dose of only gaps in the acquired volume (bottom).
uncooperative, obese patients or young 4.1 mSv or less is applied. Researchers find
children, are no longer a problem. Due to that the Flash Spiral technology “has the
its unprecedented scan speed, the Flash potential to revolutionize triple-rule-out
Source
Spiral mode even stops motion entirely, protocols.”(1) 1: Barns E. et al, High-pitch DSCT offers speedy images;
preventing image artifacts that might www.AuntMinnie.com, Nov 30, 2009.
obscure image quality and affect your 2: Press release, Andrew Stewart, Radiology Manager,
sound diagnosis.(1) St George’s Hospital, UK, published online, Jan 1, 2010.
14 Split-second scanning
15. Barrier-free pediatric Avoiding repetition of scans
imaging
Another and widely underestimated
Bringing this scan speed to imaging risk factor is eliminated as well by the
children, the most delicate patient group, Flash Spiral technology: the unnecessary
opens new possibilities by eliminating repetition of scans in young children due
the need for sedation or anesthesia. to failed sedation, which unfortunately
Researchers state that mean examination is the case in 29% of conventional
times of only 0.49 seconds provide examinations, shown in a large trial.(2)
highest image quality making sedation
or controlled ventilation unnecessary, Sub-second scanning of up to 458 mm,
Tube 1 Tube 2
while maintaining low radiation dose with a wide 78 cm bore for unrestricted
values.(1) access to your most sensitive patients,
makes a true difference in your pediatric Dual Source CT combines the data from two detectors for
Being independent of this time-consuming scanning, from saving prep time and faster table feeds above a pitch of three for revolutionary
and potentially dangerous procedure can staff, repeating scans due to motion, to triple-rule-out scanning and barrier-free pediatric imaging
save you up to 80 minutes of preparation reducing risk as well as anxiety. Yet without sedation.
time and involves less personnel. another proof for the SOMATOM Definition
A positive economic side effect of the Flash being the healthiest CT available.
SOMATOM Definition Flash for pediatric
imaging is that you can do without the
expensive services of the anesthetist.
Source
1: Lell MM. et al, Invest Radiol. Sep 17, 2010. [Epub ahead of print].
2: Malviya S. et al, British Journal of Anesthesia 84 (6): 743–8 (2000).
15
16. How it works
FAST Cardio Wizard
All heart rates, all patients Guidance for high-quality
clinical outcomes in every
The SOMATOM Definition Flash is the
fastest cardiac scanner in the industry, situation
offering a true single-segment temporal
resolution of 75 ms. Its Flash Spiral But cardiac CT examinations are also
acquires the entire heart in around among the most sophisticated and
250 ms – within a single heartbeat. demanding procedures in CT, requiring
It alternatively enables robust diagnostic careful preparation and a high degree of
outcomes, even in the presence of high expertise. All the more, it is important that
heart rates and arrhythmia, and has been the user feels sure that he has done
repeatedly proven by a wide range of everything correctly in order to achieve
clinical studies. This permits imaging the the best clinical outcome possible and to
heart without the clinical, workflow, and avoid any unnecessary radiation of the
financial aspects of utilizing beta-blockers patient. Additionally, it allows you to
when using the Flash cardio sequence. define your individual institutional guided
The realities of healthcare today often do cardiac workflow for standardization to
not permit the interruptions in workflow, guarantee continuous high-quality clinical The modifiable text in the guided workflow allows you to
longer patient preparation times, and use outcomes in every situation. define your standards and quality goals that users have to
of personnel required by the use of beta- follow in order to always achieve an optimal cardiac scan.
blockers. Not to mention the fact that Therefore, the new SOMATOM Definition
some patients should not receive beta- Flash offers the FAST Cardio Wizard,
blockers, such as in certain cases of explaining to the operator on a step-by-
pulmonary disease. All this makes the step basis what needs to be done to
Flash Cardio Sequence the industry’s most achieve an optimal cardiac scan, either in
versatile low dose mode for cardiac real-time when preparing a scan or for
imaging. training purposes.
16 Split-second scanning
17. How it works
FAST Planning
Fastest emergency CT through FAST Planning uses defined
automated planning anatomical landmarks to set the
correct recon ranges within a large
In time-critical emergency situations, scan field of view – as in trauma
long scan ranges involving different body imaging – for faster results when
regions and organs are common. The every second counts.
planning of the scan and reconstruction
field of view is prone to error and eat up
precious time to diagnosis.
FAST Planning focuses explicitly on this
critical part of the scan process. Based
on the topogram, FAST Planning assists
the scan and reconstruction planning to
provide an easier, faster, and standardized
workflow in CT scanning. The selection of
the anatomical region of interest (ROI)
from a list automatically defines
prospectively the scan and reconstruction
ranges. The scan ROIs are automatically
detected based on the characteristics of
the organ that is to be scanned. In
addition, the corresponding scan ranges
are proposed in the topogram as well. In
the case of head scans, the iso-center is
automatically adapted according to the
position of the patient’s head to prevent
cutting off important information during
the emergency examination.
17
18. syngo.via Additional Benefits with syngo.via
Make lifesaving decisions,
when every second counts …
Acute Care imaging often requires
multiple clinical disciplines such as
radiologists, cardiologists, neurologists,
and trauma surgeons to review images
to develop a structured and prioritized
treatment plan. syngo.via’s unique
information sharing makes it easy to
involve all required disciplines into the
therapeutic decision-making process.
The client/server architecture allows you
to access the data independently with
up to five users for fast parallel reading.
It allows clinicians to review the same
images on their individual workplaces For example, it enables you to conduct Dual-monitor layout for instant emergency reading
to discuss decisions remotely. a thorough analysis of the major blood process. This is the first view directly after loading
vessels of the body with their curved the patient.
The Acute Care Engine helps you in more multi-planar reformations (MPR) and
demanding cases by automatically adding appropriate display layouts the moment
incremental information for your diagnosis you open the case. Additionally, it
and supports you with a powerful set of automatically provides you with coronal,
intelligent tools. sagittal reconstructions of the patient’s
data that can be displayed in the entire
clinical network such as the ICU, the PACS
workplace, the OR, or when you discuss
the patient’s diagnosis in your office.
18 Split-second scanning
19. Rule out coronary heart The syngo.CT Cardiac Function – as part of
disease in under a minute the CT Cardio-Vascular Engine – allows
you to read and diagnose CT angiography
The moment you open a cardiac case, the images of the left side of the heart for the
Automated Case Preparation has already evaluation of ischemia or cardiomyopathy.
preprocessed the images and displays
them in your appropriate layout together Additionally, the application can evaluate
with the adequate evaluation tools. This the late or early myocardial enhancement
means that you can immediately start of single energetic CT data which is
evaluating the coronary vessels, the displayed as a color overlay. The Cardio-
functional parameters, and the prepared Vascular Engine’s Pro level provides right
calcium score. ventricular volumetric analysis,* which
may have prognostic value for congestive
The comprehensive layout for display of heart failure, chronic pulmonary disease,
multiple CPRs permits the review of the and pulmonary emboli.
coronary tree at the blink of an eye. All
your findings and key images are collected
in the Findings Navigator on-the-fly as you Single-click stenosis aneurysm measurement.
read the case. Your result: rule-out and Three reference lines are already predefined.
reporting of coronary artery disease in less
than a minute.
*The CT Acute Care Engine is pending 510(k) review and is not yet commercially available in the U.S.
19
20. Split-second scanning
Clinical Results
Motion-free emergency room trauma Flash Spiral scans of an entire body in Split-second scanning of the human heart with Flash
less than four seconds with dose usually under 5 mSv. Spiral in only 250 ms for motion-free and sharp coronary
arteries due to unmatched 75 ms temporal resolution.
20 Split-second scanning
21. Organ-based setting of scan and recon ranges with FAST Planning for a fast and more Restless children or patients who cannot hold their breath
standardized workflow at the scanner. FAST Spine allows the preparation of anatomically no longer cause time-consuming interruptions.
aligned spine recons with just a single click.
21
23. Defining
Low Dose CT
Applying the lowest radiation dose possible is of the utmost importance
for both you and, of course, your patients. Therefore you always want
to be assured that you have taken every means available to protect your
patient from unnecessary radiation. This desire lies at the heart of
our CARE (Combined Applications to Reduce Exposure) research and
development philosophy. Consequently, with Siemens’ continuing effort
to achieve highest dose protection, the new SOMATOM Definition Flash
now combines all features to reduce radiation as low as possible: next to
its already outstanding dose protection portfolio from the initial product
generation, it now adds a wide range of new and improved dose
reduction features.
CARE kV, for instance, is the industry’s first tool for automatically solving
the complex equation for optimal image quality at lowest possible dose
for each individual CT exam while considering tube voltage, tube current,
and contrast changes at different voltages and attenuation. This allows
you to benefit from the industry’s widest tube voltage range – not only
140 kV for bariatric imaging but now, if necessary, also down to 70 kV
where the Definition Flash sets new standards in pediatric safety.
Add the first, raw-data-based iterative reconstruction SAFIRE* and define
low dose for all body regions to take best care of your patients well-being.
*The information about this product is being provided for planning purposes.
The product is pending 510(k) review, and is not yet commercially available in the U.S.
23
24. Introduction
Defining Low Dose CT
Sub-mSv heart – CARE kV – solving a complex
the ultimate CARE feature equation
Discussions regarding dose in cardiac But CT scanning is not only about adapting
scanning have changed because dose mAs values: the right kV settings play an
values down to under 1 mSv are so equal, if not more important, role in
frequent that Sub-mSv heart can be choosing the right parameter to achieve
considered routine for Siemens SOMATOM optimal clinical outcome at lowest
Definition Flash owners. Such low routine possible dose. Siemens’ unique CARE kV
values have opened realistic discussions now addresses this consideration, and
about the use of Flash Spiral for early supports the user in exploiting the
detection of coronary artery disease. remaining dose-saving capabilities in
kV adaptation.
Optimizing tube current
and voltage
< 1 mSv
As early as 1994, Siemens introduced the
first versions of CARE Dose4D to actively
Flash Spiral allows for ultra-fast spiral acquisition at modulate the applied power for scans
75 ms temporal resolution with scan speed of up to depending on the patient’s anatomy. With
458 mm/s for maximum dose efficiency in your daily FAST CARE the configuration options have
clinical practice. now been made more flexible and can be
perfectly adjusted for every patient so that
you can achieve lowest possible dose at
optimal image quality in every
examination.
24 Defining low dose CT
25. Taking care of children Preventing unnecessary
radiation
The Flash Spiral scan has proven to be Routine Sub-mSv cardiac CT
a robust method for scanning children and SOMATOM Definition Flash eliminates
infants without sedation while providing unnecessary pre- and post-spiral
opens the door to early detection
high image quality at lowest possible over-radiation with its two Adaptive Dose
dose.(1) Shields offering dose reductions up to
Lowest dose in all organs
25%. It also protects dose-sensitive body
With CARE Child, offering the 70 kV regions, such as the female breast,
Adaptive Dose Shields eliminate
STRATON tube redesign together with a set eyeballs, the thyroid glands, or the unnecessary dose
of dedicated pediatric scan protocols, the gonads, through X-CARE with possible
new SOMATOM Definition Flash offers a dose reductions up to 40% while Protect radiation-sensitive organs
unique solution to provide even healthier preserving the image quality.
scanning for your youngest patients. Dose reductions in a wide range
With CARE kV you now benefit from the Iterative reconstruction of protocols with iterative
industry’s widest tube voltage range –
down to 70 kV where the new SOMATOM Siemens now introduces SAFIRE*, the first reconstruction
Definition Flash sets new standards in low raw-data-based iterative reconstruction,
dose pediatric imaging. that is a unique approach allowing for up
to 60% additional dose savings.
*The information about this product is being
Source provided for planning purposes.
1: Lell MM. et al, Invest Radiol. Sep 17, 2010. The product is pending 510(k) review, and is
[Epub ahead of print]. not yet commercially available in the U.S.
25
26. How it works
Sub-mSv Heart
20 mSv
Dose down to below 1 mSv Low dose cardiac for all
heart rates
Single source
With the SOMATOM Definition Flash,
15 mSv discussions regarding high dose versus When fully flexible X-ray pulsing meets
low dose cardiac scanning will change, 75 ms of temporal resolution, the result
10 mSv because, even under unfavorable is the Flash Cardio Sequence, the most
conditions, the patient exposure with the versatile low dose cardio scan mode on
SOMATOM Definition Flash is less than the market.
5 mSv what is required for diagnostic cardiac
cath. Many clinical trials demonstrate that The intelligently triggered sequence shuts
1 mSv high dose cardiac CT no longer exists with off radiation in the systolic phase when
Siemens equipment.(1, 2, 3) With Flash Spiral, not required and dynamically reacts to
Single-source cardiac spiral scanning requires dose values down to under 1 mSv – irregularities during the ECG trace. The
overlapping data acquisition, resulting in relatively high especially important for the most dose- real-time ECG monitoring reacts instantly
patient exposure (top). sensitive patients – are so frequent they and stops the scan until the heart rate
can be considered routine. becomes stable again. This arrhythmia
compensation method allows for high
5 mSv
Such low values can open realistic dose savings and an increased robustness
discussions about the use of CTA for early of the scan.
4 mSv
detection of coronary artery disease,
3 mSv taking advantage of its ability to scan the For the first time, a step-and-shoot mode
entire heart in only 250 ms – a quarter is robust and fast enough to freeze the
2 mSv of a heartbeat. And, for less favorable heart and visualize the coronary arteries
conditions, such as high heart rate or even at high heart rates, thus allowing
1 mSv arrhythmia, the Flash Cardio Sequence even low dose cardiac CT without the
Flash
with its automated arrhythmia need for beta-blockers.
compensation still allows dose below
diagnostic cath. Its unique dual pulsing Source
Flash Spiral with Dual Source CT allows for ultra-fast spiral even calculates the heart’s ejection 1: Leschka S. et al, Eur Radiol. 2009 Dec; 19(12): 2896–903.
acquisition for maximum dose efficiency in your daily fraction. 2: Lell M. et al, Eur Radiol. 2009 Nov; 19(11): 2576–83.
clinical practice (bottom). 3: Achenbach S. et al, Eur Heart J. 2010 Feb; 31(3): 340–6.
26 Defining low dose CT
27. How it works
CARE kV and CARE Child
Real-time dose modulation CARE kV, an extension of CARE Dose4D,
can now automatically suggest kV and
CARE Dose4D aims to regulate the effective mAs to optimize the contrast-to-
mAs so that image quality is uniform noise-ratio (CNR) of the image while
across the whole scan range. CARE Dose limiting the applied dose. The system’s
Configurator provides the user the ability proposal is based on the attenuation as
to select reference curves for each body measured in the topogram and the user-
region and for each body habitus defined acquisition type (non-contrast,
individually. With the new SOMATOM bone, soft tissue, vascular). The system
Definition Flash with FAST CARE the also identifies bariatric patients and
configuration options have now been consequently sets the parameters to make
made even more flexible for perfect full use of the system’s reserves. CARE kV 70 kV
80 kV
adjustment for every patient. is, of course, fully customizable, meaning 100 kV
that the user can choose the degree of 120 kV
Solving a complex equation system assistance between none, semi,
140 kV
and full.
The dose saving and image quality
potential of the right kV settings play an Taking care of children
equal, if not more important, role to
achieve optimal clinical outcomes. But With the new improved STRATON tube
changing kV values always comes along the voltage range is extended from 80
with the need to adapt all other values down to 70 kV where it sets new standards
according to the respective patient and in low dose pediatric imaging with CARE
the proposed examination. Unfortunately, Child. The new 70 kV scan mode further
up to now this had to be done manually reduces the dose to small pediatric or Example: For a vessel examination of a small
and required a lot of expertise. These neonate patients. These dedicated patient, CARE kV proposes scanning with 70 kV
dependencies are described in a complex pediatric scan modes take care of the well- and sets the other values for optimal image quality
physical equation, so that often the full being of our youngest patients. Overall, at lowest dose accordingly.
potential for dose reduction remained with these features, an additional dose
untapped with 120 kV being used in reduction of up to 60% is possible and
almost every adult patient. easy to achieve in clinical practice.
27
28. How it works
X-CARE
X-ray low
Additional dose reduction
of up to 40%
Siemens has recognized the importance
of dose-sensitive scanning, especially for
female patients, but also when directly
radiating the eye lens or the thyroid gland.
A simple but effective approach to lower
dose for the most dose-sensitive body
regions is partial CT scanning, that has
been integrated into dedicated protocols X-ray on
of the SOMATOM Definition Flash.
It protects these areas from direct X-ray Conventional scanning X-CARE nearly switches the
exposure by nearly switching the X-ray applies radiation permanently tube current off within a
tube off for a certain range of projections, during the full rotation, thus certain range of projections,
while automatically adjusting tube resulting in direct exposure of minimizing direct exposure
currents for the remaining projections radiation-sensitive organs, for highly dose-sensitive
to prevent deteriorating image quality. for example for the breasts. body regions.
The result with X-CARE is reduced
sensitive-area exposure up to 40% without
loss of image quality.
28 Defining low dose CT
29. How it works
SAFIRE
Iterative Reconstruction with homologous reference data. This Standard Filtered SAFIRE*
procedure can be regarded as validating Back Projection
SAFIRE* – Sinogram Affirmed Iterative (or affirming) the current images.
Reconstruction – for the first time allows
to utilize the full dose-saving potential An updated image is then again recon-
of the iterative reconstruction in clinical structed, using the detected deviation
practice. Now, raw-data information information. In each iteration a dynamic
(which is visualized in the so-called raw-data-based noise model is applied
Raw data
sinogram) is actually being utilized in that allows for reduction of image noise
recon Raw data Image data Image
the image improvement process. without noticeable loss of sharpness. This recon recon correction
optimization process thus makes even
After the initial reconstruction using the better use of the diagnostic information
weighted filtered back projection (WFBP) contained in the raw data. Using multiple
the first iterative reconstruction loop is iterations, geometrical imperfections of
performed. The CT images are retrans- the WFBP are corrected in addition to
ferred to raw data which models all incrementally reducing image noise.
relevant geometrical properties of the CT
scanner. This step reproduces CT raw data With this, SAFIRE* allows for a radiation Ultra-fast reconstruction More powerful dose
like a real scanner does. By comparing dose reduction of up to 60% or improved without iterations reduction than image-
this synthetic raw data with the acquired image quality in regards to contrast, Well-established image based methods
data, differences are identified. A further sharpness, and noise. impression Well-established image
iteration loop compares the images Limited dose reduction impression
Superior image quality
Fast reconstruction in
image and raw-data space
and improved workflow
with variable settings
*The information about this product is being
provided for planning purposes.
The product is pending 510(k) review, and
is not yet commercially available in the U.S.
29
30. syngo.via Additional benefits with syngo.via
CT Acute Care Engine disease, aortic dissection, or pulmonary
embolism. syngo.CT Coronary Analysis,
Make lifesaving decisions, when every as a part of the CT Acute Care Engine,
second counts … evaluates the coronary status and
quantifies stenoses in less than one
CT is the modality of choice when it minute through Single Click Stenosis
comes to diagnostic imaging in acute care measurement. syngo.CT’s Cardiac Function
situations, whether it is for a triple-rule-out is also able to evaluate whether the
of acute chest pain, for stroke assessment, myocardial function has already been
polytrauma, or for acute abdominal pain. affected by an infarction, while syngo.CT
The CT Acute Care Engine provides clinical Vascular Analysis with VesselSURF is the
functionality that delivers decisive results perfect tool to assess the extent of an
Tube 1 Tube 2
for all of these challenging indications. aortic dissection, or to evaluate a
syngo.via’s workflow is another remarkable pulmonary embolism.
feature, as the Direct Image Transfer, Dual Source CT combines the data from two detectors
Study Split for parallel assessment with Flash Spiral scanning of the for faster table feeds above a pitch of three.
up to five parallel readers, together with entire thorax below 4 mSv
Automated Case Preparation, make the
CT Acute Care Engine the zero-delay The prospectively triggered Flash Spiral
diagnostic tool. Above all, speed and scan perfectly meets the need for patients
dependability add confidence for critical who present with acute chest pain to
decisions made against the clock. exclude coronary artery disease,
pulmonary embolism, and aortic
The CT Acute Care Engine* provides dissection. The average dose for this high
comprehensive image-processing speed examination is 1.6 mSv for patients
functionality for triple-rule-out of acute who can be scanned with 100 kV protocols
chest pain caused by coronary heart and 3.2 mSv for patients who can be * The CT Acute Care Engine is pending 510(k) review and is not yet
scanned with 120 kV protocols. commercially available in the U.S.
30 Defining low dose CT
31. The prospectively triggered high-pitch
Flash Spiral scan mode for triple-rule-out
allows motion-artifact-free and accurate
visualization of the entire thoracic vessels,
including the aorta, pulmonary, and
coronary arteries at dose levels, before
unseen, of below 4 mSv.
syngo.via automatically displays the
acquired data in the appropriate layout
and has preprocessed it according to the
triple-rule-out specific (disease-oriented)
workflow for a quick rule-out in less than
four minutes.
Triple-rule-out of coronary artery disease, aortic dissection, or pulmonary embolism in less than four minutes.
31
32. Defining low dose CT
Clinical Results
CARE Child, with the 70 kV STRATON tube, defines new low dose Sub-mSv heart, the ultimate CARE feature. Dose values down to under
safety and image quality standards in pediatric imaging. 1 mSv are so frequent that Sub-mSv heart can be considered routine for
SOMATOM Definition Flash users.
32 Defining low dose CT
33. Thoracoabdominal aorta examination, including the coronary arteries, with 1.9 mSv low dose Flash Spiral scan together with iterative reconstruction of
dose below 5 mSv, automatically preprocessed in syngo.via, showing aortic a newborn after perinatal complications.
insufficiency.
33
35. Dual Source DE
for all Patients
It has always been a CT goal to collect as much information as possible in
order to differentiate tissues. With Dual Energy scanning, the SOMATOM
Definition and SOMATOM Definition Flash open the door to a new world
of characterization, visualizing the chemical composition of material. The
idea of Dual Energy is not new to the CT community. Earlier approaches,
including two subsequent scans at different tube voltages or two
subsequent scans at the same position, failed to seamlessly align the
imaged anatomy and to capture the same phase of contrast
enhancement.
Dual Energy was first successfully introduced into clinical practice with
Dual Source CT, i.e. two X-ray tubes and two UFC (Ultra-Fast Ceramic)
detectors mounted at 90 degrees from each other and perfectly
synchronized during scans. And, to date, Dual Source remains the only
modality that enables the usage of Dual Energy in daily practice at a dose
comparable to a conventional 120 kV scan and with optimum spectra
separation for highest value DE information.
With 12 FDA-cleared applications and more than 700 Dual Source CTs
installed, the number of Dual Energy scans has skyrocketed worldwide
and is expected to continue increasing at an even higher rate. Dual
Energy with Dual Source CT adds the decisive diagnostic confidence for
sustainable and sound treatment decisions – it is the advantage that
proves itself over and over in daily practice.
35
36. Introduction
Dual Source DE for all Patients
Selective Dual Source Dual Energy Dose-neutral every day
Photon Shield setting the standards Dual Energy imaging
Dual Source Dual Energy (DE) CT An additional benefit is the fact that all
acquisition provides an expanded set of renowned dose-saving techniques, such
diagnostic capabilities and alters CT as CARE Dose4D, Adaptive Dose Shield,
imaging in significant ways. Clinicians in and X-CARE, can be applied to effectively
700 international institutions, working achieve dose-neutral Dual Energy imaging
with SOMATOM Definition and Definition for everyday usage without a dose
Flash, are setting the technological and penalty compared to a conventional 120 kV
clinical benchmark in Dual Energy scan.(1, 2, 3) Moreover, with Dual Source
imaging. Dual Energy you can now get motion-free
80 kV 140 kV diagnostic images with a temporal
Attenuation B Attenuation A Most important and most obvious with the resolution of down to 75 ms in Cardiac
Dual Source approach: detector units can Dual Energy imaging.
Always a dose-neutral
operate at different tube potentials during
second contrast.
the synchronous CT acquisition. This avoids
spectral contamination or waste of applied
dose occurring during kV-switching time
intervals. Furthermore, the Dual Source
approach allows the introduction of X-ray
filters such as the Selective Photon Shield
for even further spectral separation.
Source
1: Schenzle JC. et al, Radiol. 2010 Jun; 45(6): 347–53.
2: Graser A. et al, Invest Radiol. 2010 Jul; 45(7): 399–405.
3: Thomas C. et al, Invest Radiol. 2010 Jul; 45(7): 393–8.
36 Dual Source DE for all patients
37. Dual Energy for all patients Already clinical routine
Dual Source DE brings new levels of More than 130 peer-reviewed publications Always second contrast at no dose
contrast, for instance with Optimum for our 12 FDA-approved DE applications
Contrast, to all images over a broad range provide evidence and identify the
penalty
of routine examinations. It offers improvements in clinical outcome as a
significant patient benefit improving result of their implementation. 800,000
Wide range of 12 FDA-cleared
diagnostic outcomes through improved successful DE examinations have already applications
lesion detection, removal of bone and helped to detect pulmonary embolisms in
plaque, improved visualization of metal lung vessels, to directly remove bone and Optimum Contrast in every image
prostheses, chemical analysis of normal plaque in angiographies, to characterize
and pathologic tissue, and iodine mapping. renal calculi, or to allow for enhanced Improved visualization of metal
It may grant the decisive diagnostic lesion conspicuity through Optimum
information for a safe, sound, and Contrast, or simply to speed up workflow
prostheses
sustainable diagnosis and treatment through Virtual Non-Contrast Imaging.
planning in any of the patients entrusted
75 ms high temporal resolution DE
to you. freezing any cardiac motion
syngo.via automatic virtual non-
contrast bone and hard plaque
removal
syngo.via auto-preprocessing for
immediate sagittal/coronal display
37
38. How it works
Single-Source CT
Dual Source Dual Energy (DE)
The X-ray tube’s kilo voltage (kV) Benefits of
determines the average energy level of Dual Source scanning
the X-ray beam. Changing the kV setting
120 kV
results in an alteration of photon energy Using the two Z-Sharp STRATON tubes,
and a changed attenuation of the Dual Source data acquisition allows for
materials scanned. For instance, scanning at least 1,152 projections per rotation Single-source CT only provides one energy level for
an object with 80 kV results in a different and spectrum. This provides homogeneous morphology imaging.
attenuation than with 140 kV. In addition, image quality over the entire FOV.
this attenuation depends also on the type In spiral mode the same slice is acquired
of tissue scanned. While the CT value for within the same time interval for both
iodine is highest at the low-energy scans, spectra, so the reconstructed images show
it can be less than half in the high-energy no time offset. The fast gantry rotation of Dual Source CT
scans. The attenuation of bones, on the 0.28 seconds, with only 0.24 ms sampling
other hand, changes much less when time, minimizes motion artifacts, while all
exposed to low-energy scans compared renown dose-saving techniques can be
to high-energy voltage examinations. applied, such as CARE Dose4D, Adaptive
Dose Shield, and X-CARE. In addition,
The material-specific difference in IRIS and SAFIRE* iterative reconstruction
attenuation enables an easy classification techniques can be applied.
of the elementary chemical composition
of the scanned tissue. In addition, a fused Monoenergetic imaging
image is provided for initial diagnosis.
Using the SOMATOM Definition Flash
also allows obtaining monoenergetic CT
images. These are similar to images
acquired with a synchrotron X-ray beam
80 kV 140 kV
Attenuation B Attenuation A
of single photon energy. The equivalent
*The information about this product is being
photon energy between 40 keV and
provided for planning purposes. 190 keV (151 steps) can be optimized Two X-ray sources set to different kV levels simultaneously
The product is pending 510(k) review, and interactively to provide best contrast for acquire two data sets at different attenuation levels.
is not yet commercially available in the U.S. the lesion of interest.
38 Dual Source DE for all patients
39. How it works
Selective Photon Shield
Without Selective Photon Shield
number of quanta
80 kV
140 kV
overlap
Eliminating unnecessary Better dose efficiency
radiation
While Dual Source technology has already
An important factor in making dose overcome this limitation, the Selective
neutrality viable is the development of Photon Shield further increases dose
the Selective Photon Shield that blocks efficiency by filtering out unnecessary
unnecessary photons of the X-ray energy photons of the high-energy X-ray tube.
spectrum. The result is a much better The remaining photon spectrum is photon energy
separation of the 80 kV and 140 kV therefore better focused and more clearly
images, as the second detector is 25% separated from the photons emitted by With Selective Photon Shield
larger than previously. the low-energy tube. The result is a much number of quanta
better separation of the 80/140 kV images,
80 kV
In effect, the Selective Photon Shield increasing bone-iodine differentiation
140 kV
assures dose neutrality for single-dose by up to 80% while reducing overall dose.
overlap
Dual Energy by avoiding unnecessary Therefore, the high-quality 80/140 kV
exposure. Thus it makes Dual Energy as mode is ideal for the head and extremities,
dose-efficient as conventional 120 kV especially CT angiographies.
scans. So all the diagnostic advantages of
Dual Energy imaging are now available The spectral separation through the
with the same dose as a single energy Selective Photon Shield on the other hand,
scan. opens the possibility to use 100/140 kV
imaging with still 30% better bone-iodine
contrast and more power reserves for photon energy
cardio, abdomen, pelvis, and larger
patients in general, making Dual Energy a The Selective Photon Shield increases energy
clinical application for all your patients. separation and reduces unnecessary dose
by blocking low-energy photons out of the
high-energy X-ray tube’s spectrum. This
results in optimal information quality and
dose neutrality compared to a conventional
120 kV scan.
39
40. How it works
Optimum Contrast
Maximizing anatomic the detail from the 140 kV images in non-
information enhanced areas, an optimized image can
be automatically calculated. It is especially
Dual Energy can be used to enhance the helpful in enhancing conspicuity of lesions
iodine signal. It is well-known that the for a safe, sound, and sustainable therapy
iodine signal is potentiated at low tube planning that may improve outcome, cost
energies (80 and 100 kV), yet lower tube effectiveness, and patient comfort.
energies are not employed in general CT
scanning because of increased noise. syngo.via enhanced
This is what builds the foundation of Dual DE imaging
Energy Optimum Contrast.
80 kV scan 140 kV scan syngo.via dose not only provides you
Focus: iodine, high Focus: soft tissue Optimum Contrast with the result images, for instance of
contrast and low image noise Optimum Contrast, in all standard views
The images obtained at 80 and 140 kV such as coronal, sagittal, and axial. It also
automatically exploit the spectral behavior automatically removes bone and hard
of certain materials or tissues in syngo.via. plaque in the major vessels for a easier
Additionally, average images can be assessment of the true lumen.
calculated to provide a ”normal” CT image,
because the 140 kV images lack contrast, With syngo.via clients, your results, such
while the 80 kV images are naturally more as Dual Energy Brain Hemorrhage images,
noisy. can be instantaneously displayed in the
OR* or the angio suite.
By adding more of the contrast
information from the 80 kV images in
Best of both worlds to maximize areas of iodine enhancement, and more of
anatomic information: less noise
and more contrast than standard *Usage of syngo.via for an emergency case
CT images. requires customer to provide respective
emergency measures in case of non-availability
of system or network.
40 Dual Source DE for all patients
41. How it works
High Temporal Resolution DE
Dual Energy Flash Cardio Dual Energy Heart Perfused
Blood Volume
Another CT first: the SOMATOM Definition
Flash allows scanning the entire heart, With its high temporal resolution, Dual
and then evaluating the coronaries with a Source CT has greatly improved coronary
full temporal resolution of 75 ms as well CT angiography, because it is less sensitive
as, in a second reconstruction, visualizing to high heart rates or arrhythmia than
perfusion defects in the myocardium, other types of scanners. With Dual
thus combining the maximum speed of Energy CT, it is now possible to highlight 80 kV 140 kV
Dual Source CT with Dual Energy imaging iodine content to visualize organ Attenuation B Attenuation A
in a single scan. This has been made perfusion. Prospectively triggered
possible with our latest reconstruction sequence or retrospectively gated spiral
technology, that allows achieving Dual acquisition modes are available for first
Source temporal resolution from image pass or late enhancement Dual Energy
components acquired at different energy myocardial perfusion studies. The
levels. The result is the ability to obtain corresponding syngo Dual Energy Heart
diagnostic Dual Energy CT images without PBV software color-codes myocardial
the use of beta-blockers. perfusion, so that both coronary artery 140 ms reconstruction 75 ms high temporal
morphology and myocardial perfusion (low spatial frequencies) resolution reconstruction
can be assessed in a single CT scan. (high spatial frequencies)
Result: high temporal
resolution DE
High 75 ms temporal resolution Dual Energy freezes
even cardiac motion and allows color-coded perfused
myocardial blood pool evaluation, for example for
patients suspected of having an acute myocardial
infarction.
41
42. syngo.via Additional Benefits with syngo.via
Speed in routine – power
in challenging cases
The new CT Cardio-Vascular Engine offers
excellent functionality for the automatic
anatomical evaluation, quantification, and
functional assessment of CT angiography
images of the heart or the peripheral
vessels, while allowing manual interaction
for challenging cases at any time.
Before you open a case, the Automated
Case Preparation has already pre-
processed the images, including the Dual
Energy direct bone and hard plaque
removal and displays them in your
appropriate layout together with the
adequate evaluation tools.
You can immediately start evaluating syngo.via showing a severely calcified
the major blood vessels of the body with thoracic aorta in which Dual Energy
their curved multi-planar reformations direct bone and hard plaque removal was
(MPR) and appropriate display layouts. automatically applied in the background –
Additionally, it automatically provides you before you opened the case. A single
with coronal, sagittal reconstructions of click on your patient in your private
the patient’s data that can be displayed in Worklist opens the case the way it is
the entire clinical network such as the ICU, displayed here.
the PACS workplace, or when you discuss
the patient’s diagnosis in your office. *Not commercially available in the US.
42 Dual Source DE for all patients
43. From scan to diagnosis status of the vascular structures and
in under ten minutes the brain tissue for these patients –
from scanning to diagnosis in less than
CT Neuro imaging is very often a matter ten minutes including Dual Energy data
of life-and-death therapeutic decision- into the disease-oriented workflow for
making. From infarctions caused by stroke seamless integration into your clinical
and extensive bleeding, to subarachnoid practice. Using data delivered by the
hemorrhage and a ruptured aneurysm – Adaptive 4D Spiral, perfusion assessment
seeing them clearly is essential because of the brain can easily be integrated in the
of the huge difference it makes in assessment. The CT Neuro Engine also
determining treatment. The new CT Neuro helps identify fractures after an accident
Engine provides tools and workflows that and, for instance, uncovers the potential
help deliver a complete and accurate stenosis when looking at the vascularity
of the neck.
If a Dual Energy examination, such as a
Dual Energy Brain Hemorrhage calculation
was made, the data is automatically
displayed together with all your other pre-
processed data. So Dual Energy data,
seamlessly integrated in syngo.via, may
give you the decisive diagnostic
information for taking sound, safe, and
sustainable treatment decisions in any
patient.
43
44. Dual Source DE for all patie
Clinical Results
Single dose Dual Energy shows a lung perfusion defect in the right Dual Energy direct hard plaque and bone removal for immediate true lumen
lower segment – unveiling the effect of pulmonary emboli. assessment. Automatically preprocessed in syngo.via with coronal, sagittal,
and axial reformats for sound treatment decisions.
44 Dual Source DE for all patients
45. nts
Monoenergetic imaging, on the right, provides improved visualization of the Dual Energy Optimum Contrast (right) combines the advantages of low and high kV
metal screws relative to the surrounding bone tissue. CT scans for enhanced lesion conspicuity in iodine-enhanced CT images.
45
46. Customer Care
Dedicated to Your Success
Remain one step ahead and tap the Upgrades and migration: Services and support
full potential of your Siemens CT system Evolve, Expand, Elevate
with our customer care program, Life. Feel confident with our proactive
As a worldwide innovation leader in Stay competitive with up-to-date systems service solutions
medical imaging, Siemens has gained
unmatched knowledge in Computed Due to increasing healthcare demands you High system availability, diagnostic
Tomography. You can profit from excellent have to stay on the cutting edge to be confidence, and optimized workflow
CT systems and innovative, flexible, and competitive. We will help you to keep your are crucial for the success of your
comprehensive service solutions that solutions up-to-date and to keep pace with CT service. To meet your performance
enable you to concentrate on what is the latest technological advancements expectations, we systematically focus
most important for you: patient care. through the syngo Evolve program. syngo on being proactive. Based on real-time
The customer care program, Life, is Evolve offers certainty in budget planning, system monitoring we detect system
the unique solution from Siemens that feature enhancements for your CT, access errors and alert you before problems
helps you to maximize the return on to new applications, and lower cost occur. The Siemens Guardian Program™
investment throughout the entire life upgrades for your CT system. helps to make unplanned downtime a
cycle of your system. thing of the past.
46 Customer Care
47. Education and training Information
and communication
Broaden your knowledge and expertise
Be informed – get connected
Know-how is the key to success. With
our extensive portfolio of education and To ensure you are always up-to-date
training programs you can deepen your on what is happening in the CT world,
knowledge and clinical expertise. We we offer you a variety of information
show you how to maximize the benefits services including easily accessible
that can be achieved with our advanced information portals, monthly newsletters,
technology. This will help you to optimize our customer magazine SOMATOM
your workflows so you can offer an even Sessions, and the SOMATOM World
higher quality of care for your patients. Summit, our scientific user conference.
47
48. SOMATOM Definition Flash
Configuration Overview
SOMATOM Definition Flash
with FAST CARE
• All routine and advanced • High-speed whole-body coverage at Access to:
applications for clinical practice highest spatial resolution
• SAFIRE* – the first raw-data-based
• Industry’s fastest Flash Spiral • Pediatric and bariatric CT imaging with iterative reconstruction
scanning no patient exclusion
• Full FAST functionality like FAST Planning
• Full CARE functionality like CARE • Two Adaptive Dose Shields blocking and FAST Spine to raise patient-centric
kV and CARE Child, including the clinically irrelevant dose in spiral scans productivity
redesigned 70 kV STRATON tube
• 3D-guided interventional CT
• High-performance image
• Ultra-long-range dynamic
reconstruction system with
imaging (up to 48 cm) for
WorkStream 4D
whole organ coverage
• Industry’s highest – heart rate
• Scanner-injector coupling including
independent – temporal
injector protocol management
resolution of 75 ms for all heart
rates in cardiovascular imaging • Latest syngo.via Engines with automated
preprocessing tools for rapid, sound and
• State-of-the-art cardiovascular
sustainable diagnosis
imaging
• Dose-neutral Dual Energy imaging at
• Industry’s widest range of kV
high temporal resolution with 12 FDA-
steps and strongest generator
cleared applications
power
• Dynamic myocardial stress perfusion
imaging
*The information about this product is being
provided for planning purposes.
The product is pending 510(k) review, and
For more details on FAST CARE benefits for your patients, please visit www.siemens.com/fastcare is not yet commercially available in the U.S.
48 Configuration overview
49. Rotation time 0.28 s*
Number of slices 2 x 128
Generator 200 kW (2 x 100 kW)
kV steps 70, 80, 100, 120, 140 kV
Isotropic resolution 0.33 mm
Temporal resolution 75 ms*, heart-rate independent
Max. scan speed 458 mm/s* with Flash Spiral
Table load up to 300 kg/660 lbs*
Gantry opening 78 cm
*optional
49