SlideShare une entreprise Scribd logo
1  sur  2
Télécharger pour lire hors ligne
Agency Listings
Smoke Detectors with
Sounder and Relay Option
System Sensor i3™
sounder and relay smoke detectors
apply the guiding principles of installation ease,
intelligence, and instant inspection in a series of
specialty conventional devices.
Features
• 85 dB sounder
• Form C relay
• Isolated thermal sensor
• Plug-in design (base included)
• In-line terminals
• Flexible mounting options
• Stop-Drop ’N Lock™
attachment to the base
• Removable cover and chamber
• Remote maintenance signaling
• Drift compensation and smoothing algorithms
• Simplified sensitivity measurement
• Dual-color LEDs
Installation ease. Throughout the i3 series, installation is simple
with its installer-friendly base and plug-in design. The base
accommodates a broad range of back box and direct mounting
options and provides ample space for pre-wiring the device. To
complete the installation, the i3 detector plugs into its base with a
simple Stop-Drop ’N Lock action.
Intelligence. To reduce the likelihood of nuisance alarms, all
i3 detectors are equipped with both drift compensation and
smoothing algorithms. These capabilities minimize both short- and
long-term causes of nuisance alarms, such as RF interference and
dust accumulation. When connected to the 2W-MOD2 loop test/
maintenance module or an i3 Ready™
panel, 2‑wire i3 detectors can
generate a remote maintenance signal when in a maintenance or
freeze trouble condition. To measure the sensitivity of any i3 detector,
the SENS-RDR displays the reading, in terms of percent-per-foot
obscuration, within seconds.
Instant inspection. i3 has red and green LEDs to simplify local
status indication during power-up, standby, alarm, maintenance,
and freeze trouble conditions. When in alarm, i3 sounder models
generate an 85 dB temporal tone. If connected to the RRS-MOD
reversing relay/synchronization module, all i3 sounders on the loop
will activate when one detector is in alarm. The RRS-MOD also
synchronizes i3 sounder output to ensure a clear audible signal.
Should the application call for differentiating between a local and
a general alarm, the i3 line offers an isolated thermal model, which
initiates a local alarm when smoke is detected, and a general alarm
when the thermal sensor is activated.
2133372-02-E7272-1653:1643015195S911 3180932
3825 Ohio Avenue • St. Charles, IL 60174
Phone: 800-SENSOR2 • Fax: 630-377-6495
©2009 System Sensor.
Product specifications subject to change without notice.Visit systemsensor.com for
current product information, including the latest version of this data sheet.
A05-0348-004 • 6/09 • #2170
Ordering Information
Model Thermal Wiring Alarm Current
2WTA-B Yes 2-wire 130 mA max. limited by
control panel
2WTR-B Yes 2-wire 130 mA max. limited by
control panel
4WTA-B Yes 4-wire 35 mA
4WTR-B Yes 4-wire 35 mA
4WTAR-B Yes 4-wire 50 mA
4WITAR-B Yes 4-wire 50 mA
Smoke Detector Specifications
Electrical Specifications
Operating Voltage Nominal: 12/24 V non-polarized
2-wire: 8.5 V to 35 V
4-wire: 10 V to 35 V
Maximum Ripple Voltage 30% of applied voltage (peak to peak)
Standby Current 2-wire: 50 µA maximum average
4-wire: 50 µA maximum average
Peak Standby Current 2-wire: 100 µA
4-wire: n/a
Maximum Alarm Current 2-wire: 2WTR-B: 130 mA limited by control
panel
2WTA-B: 130 mA**
4-wire: 4WTA-B, 4WTR-B: 35 mA
4WTAR-B, 4WITAR-B: 50 mA
**Direct Power (Non-Reverse Polarity): 130
mA limited by panel. Reverse Polarity Power:
30 mA for the 2WTA-B in alarm; 12 mA for all
other 2WTA-B units on the loop. Add 25 mA
for the RRS-MOD reversing relay alarm current.
Alarm Contact Ratings 2-wire: n/a
4-wire: 0.5 A @ 30 V AC/DC
Form C Contact Ratings 2 A @ 30 V AC/DC
Physical Specifications
OperatingTemperature
Range
32°F to 100°F (0°C to 37.8°C)
Operating Humidity
Range
0 to 95% RH non-condensing
Thermal Sensor 135°F (57.2°C) fixed
FreezeTrouble 41°F (5°C)
Sensitivity 2.5%/ft. nominal
InputTerminals 14–22 AWG
Dimensions (including
base)
5.3 inches (134 mm) diameter, 2.0 inches
(51 mm) height
Approximate Weight 7.1 oz (200 g)
Sound Pressure Output 85 dBA (models 2WTA-B, 4WTA-B, 4WTAR-B,
and 4WITAR-B only)
Mounting 3½-inch octagonal back box, 4-inch octagonal
back box, single-gang back box, 4-inch square
back box with a plaster ring, direct mount to
ceiling
LED Modes
LED Mode Green LED Red LED Condition Duration
Power up Blink every
10 seconds
Blink every 10
seconds
Initial LED
status
indication
80 seconds
Normal
(standby)
Blink every 5
seconds
off
Out of
sensitivity
off Blink every 5
seconds
Freeze
trouble
off Blink every 10
seconds
Alarm off Solid
Power-Up Sequence for LED Indication
Condition Duration
Initial LED
status
indication
80 seconds
Architect/Engineer Specifications
Smoke detector shall be a System Sensor i3 Series model number_______,
listed to Underwriters Laboratories UL 268 for Fire Protection Signaling
Systems. The detector shall be a combination photoelectric/thermal
equipped with a sounder (model 2WTA-B, 4WTA-B), a Form C relay (model
2WTR-B), a combination sounder/relay (model 4WTAR‑B), or an isolated
thermal/sounder/relay (model 4WITAR-B). The detector shall include a
mounting base for mounting to 3½-inch and 4-inch octagonal, single-gang,
and 4-inch square back boxes with a plaster ring, or direct mount to the
ceiling using drywall anchors. Wiring connections shall be made by means
of SEMS screws. The detector shall allow pre-wiring of the base and the
head shall be a plug-in type. The detector shall have a nominal sensitivity
of 2.5 percent per foot as measured in the UL smoke box. The detector
shall be capable of automatically adjusting its sensitivity by means of drift
compensation and smoothing algorithms. The detector shall provide dual-
color LED indication that blinks to indicate power-up, normal standby, out of
sensitivity, alarm, and freeze trouble conditions. When used in conjunction
with the 2W-MOD2 module, 2-wire models shall include a maintenance
signal to indicate the need for maintenance at the alarm control panel and
shall provide a loop testing capability to verify the circuit without testing each
detector individually. When used in conjunction with the RRS-MOD module,
all i3
sounder models on a loop shall sound when one sounder alarms, all shall
be synchronized, and all sounders may be silenced from the panel.
Model Description
RRS-MOD Reversing relay/synchronization module
2W-MOD2 2-wire loop test/maintenance module
SENS-RDR Sensitivity reader
RT Removal/replacement tool
A77-AB2 Retrofit adapter bracket

Contenu connexe

Tendances

Leviton vrr15 1 lz product specification bulletin
Leviton vrr15 1 lz product specification bulletinLeviton vrr15 1 lz product specification bulletin
Leviton vrr15 1 lz product specification bulletin
Alarm Grid
 
Leviton vrs15 1 lz installation manual and setup guide
Leviton vrs15 1 lz installation manual and setup guideLeviton vrs15 1 lz installation manual and setup guide
Leviton vrs15 1 lz installation manual and setup guide
Alarm Grid
 
CONTROLLING HOME APPLIANCES USING REMOTE(1)
CONTROLLING HOME APPLIANCES USING REMOTE(1)CONTROLLING HOME APPLIANCES USING REMOTE(1)
CONTROLLING HOME APPLIANCES USING REMOTE(1)
Ambar Gupta
 
Minibatch 5-130518000824-phpapp01
Minibatch 5-130518000824-phpapp01Minibatch 5-130518000824-phpapp01
Minibatch 5-130518000824-phpapp01
Vidya Sree
 
Remote control for home appliances
Remote control for home appliancesRemote control for home appliances
Remote control for home appliances
Bharath University
 
Smart din rail module product sheet 1.3 website
Smart din rail module product sheet 1.3 websiteSmart din rail module product sheet 1.3 website
Smart din rail module product sheet 1.3 website
fifthplay
 

Tendances (19)

Leviton vrr15 1 lz product specification bulletin
Leviton vrr15 1 lz product specification bulletinLeviton vrr15 1 lz product specification bulletin
Leviton vrr15 1 lz product specification bulletin
 
Netzer ds 58-specsheet
Netzer ds 58-specsheetNetzer ds 58-specsheet
Netzer ds 58-specsheet
 
Edwards Signaling E-NAC Installation Manual
Edwards Signaling E-NAC Installation ManualEdwards Signaling E-NAC Installation Manual
Edwards Signaling E-NAC Installation Manual
 
Leviton vrs15 1 lz installation manual and setup guide
Leviton vrs15 1 lz installation manual and setup guideLeviton vrs15 1 lz installation manual and setup guide
Leviton vrs15 1 lz installation manual and setup guide
 
PR Electronics 3000 Series High Performance Temperature Transmitters and Sign...
PR Electronics 3000 Series High Performance Temperature Transmitters and Sign...PR Electronics 3000 Series High Performance Temperature Transmitters and Sign...
PR Electronics 3000 Series High Performance Temperature Transmitters and Sign...
 
CONTROLLING HOME APPLIANCES USING REMOTE(1)
CONTROLLING HOME APPLIANCES USING REMOTE(1)CONTROLLING HOME APPLIANCES USING REMOTE(1)
CONTROLLING HOME APPLIANCES USING REMOTE(1)
 
2018 AI Next / Aleph Home Security Catalog
2018 AI Next / Aleph Home Security Catalog2018 AI Next / Aleph Home Security Catalog
2018 AI Next / Aleph Home Security Catalog
 
Alarm Annunciator
Alarm AnnunciatorAlarm Annunciator
Alarm Annunciator
 
Minibatch 5-130518000824-phpapp01
Minibatch 5-130518000824-phpapp01Minibatch 5-130518000824-phpapp01
Minibatch 5-130518000824-phpapp01
 
Drager Polytron 5310 Fixed Gas Detector - Spec Sheet
Drager Polytron 5310 Fixed Gas Detector - Spec SheetDrager Polytron 5310 Fixed Gas Detector - Spec Sheet
Drager Polytron 5310 Fixed Gas Detector - Spec Sheet
 
Controlling home appliances using remote (2)
Controlling home appliances using remote (2)Controlling home appliances using remote (2)
Controlling home appliances using remote (2)
 
Remote control regulator
Remote control regulatorRemote control regulator
Remote control regulator
 
Access control basics-9
Access control basics-9Access control basics-9
Access control basics-9
 
Bussmann By Eaton - Surge Protection Devices Catalogue
Bussmann By Eaton - Surge Protection Devices CatalogueBussmann By Eaton - Surge Protection Devices Catalogue
Bussmann By Eaton - Surge Protection Devices Catalogue
 
Alarmline application guides
Alarmline application guidesAlarmline application guides
Alarmline application guides
 
Remote control for home appliances
Remote control for home appliancesRemote control for home appliances
Remote control for home appliances
 
wiDom Smart Roller Shutter Z-Wave Plus Module Manual
wiDom Smart Roller Shutter Z-Wave Plus Module ManualwiDom Smart Roller Shutter Z-Wave Plus Module Manual
wiDom Smart Roller Shutter Z-Wave Plus Module Manual
 
Smart din rail module product sheet 1.3 website
Smart din rail module product sheet 1.3 websiteSmart din rail module product sheet 1.3 website
Smart din rail module product sheet 1.3 website
 
I 9319
I 9319I 9319
I 9319
 

Similaire à System Sensor 2WTR-B Data Sheet

Similaire à System Sensor 2WTR-B Data Sheet (20)

Edwards Signaling E-IDC1B Data Sheet
Edwards Signaling E-IDC1B Data SheetEdwards Signaling E-IDC1B Data Sheet
Edwards Signaling E-IDC1B Data Sheet
 
Edwards Signaling E-IDCWS Data Sheet
Edwards Signaling E-IDCWS Data SheetEdwards Signaling E-IDCWS Data Sheet
Edwards Signaling E-IDCWS Data Sheet
 
Edwards Signaling E-NAC Data Sheet
Edwards Signaling E-NAC Data SheetEdwards Signaling E-NAC Data Sheet
Edwards Signaling E-NAC Data Sheet
 
Manual osciloscopio GDS-800
Manual osciloscopio GDS-800Manual osciloscopio GDS-800
Manual osciloscopio GDS-800
 
I 9308
I 9308I 9308
I 9308
 
Edwards Signaling E-HD Data Sheet
Edwards Signaling E-HD Data SheetEdwards Signaling E-HD Data Sheet
Edwards Signaling E-HD Data Sheet
 
Edwards Signaling RB4U Data Sheet
Edwards Signaling RB4U Data SheetEdwards Signaling RB4U Data Sheet
Edwards Signaling RB4U Data Sheet
 
4903-0010 - Conventional Strobe with Horn.pdf
4903-0010 - Conventional Strobe with Horn.pdf4903-0010 - Conventional Strobe with Horn.pdf
4903-0010 - Conventional Strobe with Horn.pdf
 
CINT alarm systems
CINT alarm systemsCINT alarm systems
CINT alarm systems
 
System Sensor 2151 Data Sheet
System Sensor 2151 Data SheetSystem Sensor 2151 Data Sheet
System Sensor 2151 Data Sheet
 
Universal Dimmer 250W Z-Wave+ Fibaro Manual
Universal Dimmer 250W  Z-Wave+ Fibaro ManualUniversal Dimmer 250W  Z-Wave+ Fibaro Manual
Universal Dimmer 250W Z-Wave+ Fibaro Manual
 
Trio tm-50.0 60.0-bcd.00658_en_rev_e
Trio tm-50.0 60.0-bcd.00658_en_rev_eTrio tm-50.0 60.0-bcd.00658_en_rev_e
Trio tm-50.0 60.0-bcd.00658_en_rev_e
 
ABB-TRIO-TM-50.0-400-POWER-MODULE
ABB-TRIO-TM-50.0-400-POWER-MODULEABB-TRIO-TM-50.0-400-POWER-MODULE
ABB-TRIO-TM-50.0-400-POWER-MODULE
 
Fault Isolator Base - 4098-9793.pdf
Fault Isolator Base - 4098-9793.pdfFault Isolator Base - 4098-9793.pdf
Fault Isolator Base - 4098-9793.pdf
 
Sd355
Sd355Sd355
Sd355
 
WIRELESS FIRE ALARM & MONITOR ON LCD
WIRELESS FIRE ALARM & MONITOR ON LCDWIRELESS FIRE ALARM & MONITOR ON LCD
WIRELESS FIRE ALARM & MONITOR ON LCD
 
Ad355
Ad355Ad355
Ad355
 
Presentation o surge protection devices
Presentation o surge protection devicesPresentation o surge protection devices
Presentation o surge protection devices
 
D4120
D4120D4120
D4120
 
Vertx v100 ds_en
Vertx v100 ds_enVertx v100 ds_en
Vertx v100 ds_en
 

Plus de JMAC Supply

Plus de JMAC Supply (20)

Bosch ALTV244UL Data Sheet
Bosch ALTV244UL Data SheetBosch ALTV244UL Data Sheet
Bosch ALTV244UL Data Sheet
 
Bosch AL1002WAL Data Sheet
Bosch AL1002WAL Data SheetBosch AL1002WAL Data Sheet
Bosch AL1002WAL Data Sheet
 
Bosch AIM-AEC21-CVT Data Sheet
Bosch AIM-AEC21-CVT Data SheetBosch AIM-AEC21-CVT Data Sheet
Bosch AIM-AEC21-CVT Data Sheet
 
Bosch AI1 Data Sheet
Bosch AI1 Data SheetBosch AI1 Data Sheet
Bosch AI1 Data Sheet
 
Bosch AH-24WP-R Data Sheet
Bosch AH-24WP-R Data SheetBosch AH-24WP-R Data Sheet
Bosch AH-24WP-R Data Sheet
 
Bosch AEC-8I8O-EXT Data Sheet
Bosch AEC-8I8O-EXT Data SheetBosch AEC-8I8O-EXT Data Sheet
Bosch AEC-8I8O-EXT Data Sheet
 
Bosch AE774 Data Sheet
Bosch AE774 Data SheetBosch AE774 Data Sheet
Bosch AE774 Data Sheet
 
Bosch AE203R Data Sheet
Bosch AE203R Data SheetBosch AE203R Data Sheet
Bosch AE203R Data Sheet
 
Bosch AE101 Data Sheet
Bosch AE101 Data SheetBosch AE101 Data Sheet
Bosch AE101 Data Sheet
 
Bosch AE4 Data Sheet
Bosch AE4 Data SheetBosch AE4 Data Sheet
Bosch AE4 Data Sheet
 
Bosch AE1 Data Sheet
Bosch AE1 Data SheetBosch AE1 Data Sheet
Bosch AE1 Data Sheet
 
Bosch ACD-IC16K37-50 Data Sheet
Bosch ACD-IC16K37-50 Data SheetBosch ACD-IC16K37-50 Data Sheet
Bosch ACD-IC16K37-50 Data Sheet
 
Bosch ACD-IC2K37-50 Data Sheet
Bosch ACD-IC2K37-50 Data SheetBosch ACD-IC2K37-50 Data Sheet
Bosch ACD-IC2K37-50 Data Sheet
 
Bosch ACA-IC2K26-10 Data Sheet
Bosch ACA-IC2K26-10 Data SheetBosch ACA-IC2K26-10 Data Sheet
Bosch ACA-IC2K26-10 Data Sheet
 
Bosch 9208B Data Sheet
Bosch 9208B Data SheetBosch 9208B Data Sheet
Bosch 9208B Data Sheet
 
Bosch 7110XC Data Sheet
Bosch 7110XC Data SheetBosch 7110XC Data Sheet
Bosch 7110XC Data Sheet
 
Samsung Techwin SNB-1000 Data Sheet
Samsung Techwin SNB-1000 Data SheetSamsung Techwin SNB-1000 Data Sheet
Samsung Techwin SNB-1000 Data Sheet
 
Samsung Techwin SMT-4031 Data Sheet
Samsung Techwin SMT-4031 Data SheetSamsung Techwin SMT-4031 Data Sheet
Samsung Techwin SMT-4031 Data Sheet
 
Samsung Techwin SMT-4023 Data Sheet
Samsung Techwin SMT-4023 Data SheetSamsung Techwin SMT-4023 Data Sheet
Samsung Techwin SMT-4023 Data Sheet
 
Samsung Techwin SMT-3232 Data Sheet
Samsung Techwin SMT-3232 Data SheetSamsung Techwin SMT-3232 Data Sheet
Samsung Techwin SMT-3232 Data Sheet
 

Dernier

Dernier (20)

Exploring Multimodal Embeddings with Milvus
Exploring Multimodal Embeddings with MilvusExploring Multimodal Embeddings with Milvus
Exploring Multimodal Embeddings with Milvus
 
Understanding the FAA Part 107 License ..
Understanding the FAA Part 107 License ..Understanding the FAA Part 107 License ..
Understanding the FAA Part 107 License ..
 
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data DiscoveryTrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
 
Six Myths about Ontologies: The Basics of Formal Ontology
Six Myths about Ontologies: The Basics of Formal OntologySix Myths about Ontologies: The Basics of Formal Ontology
Six Myths about Ontologies: The Basics of Formal Ontology
 
AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of Terraform
 
[BuildWithAI] Introduction to Gemini.pdf
[BuildWithAI] Introduction to Gemini.pdf[BuildWithAI] Introduction to Gemini.pdf
[BuildWithAI] Introduction to Gemini.pdf
 
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
 
"I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ..."I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ...
 
DBX First Quarter 2024 Investor Presentation
DBX First Quarter 2024 Investor PresentationDBX First Quarter 2024 Investor Presentation
DBX First Quarter 2024 Investor Presentation
 
presentation ICT roal in 21st century education
presentation ICT roal in 21st century educationpresentation ICT roal in 21st century education
presentation ICT roal in 21st century education
 
Rising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdf
Rising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdfRising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdf
Rising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdf
 
CNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In PakistanCNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In Pakistan
 
Vector Search -An Introduction in Oracle Database 23ai.pptx
Vector Search -An Introduction in Oracle Database 23ai.pptxVector Search -An Introduction in Oracle Database 23ai.pptx
Vector Search -An Introduction in Oracle Database 23ai.pptx
 
DEV meet-up UiPath Document Understanding May 7 2024 Amsterdam
DEV meet-up UiPath Document Understanding May 7 2024 AmsterdamDEV meet-up UiPath Document Understanding May 7 2024 Amsterdam
DEV meet-up UiPath Document Understanding May 7 2024 Amsterdam
 
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
 
Boost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfBoost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdf
 
WSO2's API Vision: Unifying Control, Empowering Developers
WSO2's API Vision: Unifying Control, Empowering DevelopersWSO2's API Vision: Unifying Control, Empowering Developers
WSO2's API Vision: Unifying Control, Empowering Developers
 
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
 
Artificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : UncertaintyArtificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : Uncertainty
 

System Sensor 2WTR-B Data Sheet

  • 1. Agency Listings Smoke Detectors with Sounder and Relay Option System Sensor i3™ sounder and relay smoke detectors apply the guiding principles of installation ease, intelligence, and instant inspection in a series of specialty conventional devices. Features • 85 dB sounder • Form C relay • Isolated thermal sensor • Plug-in design (base included) • In-line terminals • Flexible mounting options • Stop-Drop ’N Lock™ attachment to the base • Removable cover and chamber • Remote maintenance signaling • Drift compensation and smoothing algorithms • Simplified sensitivity measurement • Dual-color LEDs Installation ease. Throughout the i3 series, installation is simple with its installer-friendly base and plug-in design. The base accommodates a broad range of back box and direct mounting options and provides ample space for pre-wiring the device. To complete the installation, the i3 detector plugs into its base with a simple Stop-Drop ’N Lock action. Intelligence. To reduce the likelihood of nuisance alarms, all i3 detectors are equipped with both drift compensation and smoothing algorithms. These capabilities minimize both short- and long-term causes of nuisance alarms, such as RF interference and dust accumulation. When connected to the 2W-MOD2 loop test/ maintenance module or an i3 Ready™ panel, 2‑wire i3 detectors can generate a remote maintenance signal when in a maintenance or freeze trouble condition. To measure the sensitivity of any i3 detector, the SENS-RDR displays the reading, in terms of percent-per-foot obscuration, within seconds. Instant inspection. i3 has red and green LEDs to simplify local status indication during power-up, standby, alarm, maintenance, and freeze trouble conditions. When in alarm, i3 sounder models generate an 85 dB temporal tone. If connected to the RRS-MOD reversing relay/synchronization module, all i3 sounders on the loop will activate when one detector is in alarm. The RRS-MOD also synchronizes i3 sounder output to ensure a clear audible signal. Should the application call for differentiating between a local and a general alarm, the i3 line offers an isolated thermal model, which initiates a local alarm when smoke is detected, and a general alarm when the thermal sensor is activated. 2133372-02-E7272-1653:1643015195S911 3180932
  • 2. 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2009 System Sensor. Product specifications subject to change without notice.Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0348-004 • 6/09 • #2170 Ordering Information Model Thermal Wiring Alarm Current 2WTA-B Yes 2-wire 130 mA max. limited by control panel 2WTR-B Yes 2-wire 130 mA max. limited by control panel 4WTA-B Yes 4-wire 35 mA 4WTR-B Yes 4-wire 35 mA 4WTAR-B Yes 4-wire 50 mA 4WITAR-B Yes 4-wire 50 mA Smoke Detector Specifications Electrical Specifications Operating Voltage Nominal: 12/24 V non-polarized 2-wire: 8.5 V to 35 V 4-wire: 10 V to 35 V Maximum Ripple Voltage 30% of applied voltage (peak to peak) Standby Current 2-wire: 50 µA maximum average 4-wire: 50 µA maximum average Peak Standby Current 2-wire: 100 µA 4-wire: n/a Maximum Alarm Current 2-wire: 2WTR-B: 130 mA limited by control panel 2WTA-B: 130 mA** 4-wire: 4WTA-B, 4WTR-B: 35 mA 4WTAR-B, 4WITAR-B: 50 mA **Direct Power (Non-Reverse Polarity): 130 mA limited by panel. Reverse Polarity Power: 30 mA for the 2WTA-B in alarm; 12 mA for all other 2WTA-B units on the loop. Add 25 mA for the RRS-MOD reversing relay alarm current. Alarm Contact Ratings 2-wire: n/a 4-wire: 0.5 A @ 30 V AC/DC Form C Contact Ratings 2 A @ 30 V AC/DC Physical Specifications OperatingTemperature Range 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed FreezeTrouble 41°F (5°C) Sensitivity 2.5%/ft. nominal InputTerminals 14–22 AWG Dimensions (including base) 5.3 inches (134 mm) diameter, 2.0 inches (51 mm) height Approximate Weight 7.1 oz (200 g) Sound Pressure Output 85 dBA (models 2WTA-B, 4WTA-B, 4WTAR-B, and 4WITAR-B only) Mounting 3½-inch octagonal back box, 4-inch octagonal back box, single-gang back box, 4-inch square back box with a plaster ring, direct mount to ceiling LED Modes LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Power-Up Sequence for LED Indication Condition Duration Initial LED status indication 80 seconds Architect/Engineer Specifications Smoke detector shall be a System Sensor i3 Series model number_______, listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a combination photoelectric/thermal equipped with a sounder (model 2WTA-B, 4WTA-B), a Form C relay (model 2WTR-B), a combination sounder/relay (model 4WTAR‑B), or an isolated thermal/sounder/relay (model 4WITAR-B). The detector shall include a mounting base for mounting to 3½-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent per foot as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual- color LED indication that blinks to indicate power-up, normal standby, out of sensitivity, alarm, and freeze trouble conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. When used in conjunction with the RRS-MOD module, all i3 sounder models on a loop shall sound when one sounder alarms, all shall be synchronized, and all sounders may be silenced from the panel. Model Description RRS-MOD Reversing relay/synchronization module 2W-MOD2 2-wire loop test/maintenance module SENS-RDR Sensitivity reader RT Removal/replacement tool A77-AB2 Retrofit adapter bracket