2-Wire Photoelectric
Duct Smoke Detector

The InnovairFlex™ Series are the only duct smoke

detectors flexible enough to fit configurations from

square to rectangular and everything in between.

Features                                                               The InnovairFlex D2 2-wire photoelectric duct smoke detector
                                                                       features a pivoting housing that fits various applications: both square
•	Photoelectric, integrated low-flow technology
                                                                       and rectangular footprints mount to round or rectangular duct work.
•	Air velocity rating from 100 ft/min to 4,000 ft/min
  (0.5 m/s to 20.32 m/sec)                                             This new duct smoke detector senses airflow speeds ranging
•	Versatile mounting options in square or rectangular configuration    from 100 to 4,000 feet per minute with proven System Sensor
  with modular construction                                            precision. The enhancements built into this model improve false
                                                                       alarm immunity (with plug-in sensor head); broaden operating
•	Plug-in sensor
                                                                       temperature (−4°F to 158°F) and humidity (0 to 95 percent non-
•	Superb false alarm immunity with the latest sensor technology        condensing) ranges; while simplifying installation and maintenance.
•	Broader ranges for operating temperature (−4°F to 158°F) and         These advance features can detect smoke even in the harshest duct
  humidity (0% to 95% non-condensing)                                  applications.

•	Patented sampling tube installs from front or back of the detector
                                                                       The new design provides more wiring space with an added ¾ inch
  with no tools required
                                                                       conduit knockout. Numbers and labels for terminal designations are
•	A cover tamper feature to indicate a trouble condition for removed   consistent with previous Innovair models. The new sampling tube
  or improperly installed sensor cover                                 can be clicked into position with one smooth motion from either the
•	Increased wiring space with a newly added ¾ inch conduit             front or the back of the detector.
  knockout
                                                                       The InnovairFlex D2 duct smoke detector has signals to indicate
•	Improved LED status
                                                                       trouble and maintenance conditions. Additionally, a cover tamper
•	24 VDC                                                               feature is incorporated to indicate a trouble condition for removed
•	Backward compatibility with existing Innovair products, including    or improperly installed sensor cover. An improved cover design, with
  remote accessories                                                   an integrated the low-flow feature, isolates the sensor head from the
                                                                       low-flow technology for simple maintenance.

                                                                       The InnovairFlex series is designed for greater flexibility and reliable
                                                                       smoke detection to simplify installation and maintenance. The new
                                                                       InnovairFlex product line is backward compatible to existing Innovair
                                                                       models, including remote test accessories

                                                                       WARNING: Duct smoke detectors have specific limitations.

Agency Listings                                                        DUCT SMOKE DETECTORS ARE:
                                                                       NOT a substitute for an open area smoke detector,
                                                                       NOT a substitute for early warning detection, and
                                                                       NOT a replacement for a building’s regular fire detection system.
                                                                       Refer to NFPA 72 and 90A for additional duct smoke detector
   S911            3029700        3242-1653:206         2202           application information.
InnovairFlex Duct Smoke Detector Specifications
 Architectural/Engineering Specifications
 The air duct smoke detector shall be a System Sensor InnovairFlex™ D2 Photoelectric Duct Smoke Detector. The detector housing shall be UL listed per UL
 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits both square and rectangular footprints. The detector
 shall operate at air velocities of 100 ft/min to 4000 ft/min (0.5 m/sec to 20.32 m/sec). The unit shall be capable of providing a trouble signal in the event that
 the sensor cover is removed or improperly installed. It shall be capable of local testing via magnetic switch or remote testing using the RTS451KEY remote test
 station. Terminal connections shall be of the strip and clamp method suitable for 12–18 AWG wiring.

 Physical Specifications
 Size: (Rectangular)                          14.38 in (37 cm) Length; 5 in (12.7 cm) Width; 2.5 in (6.36 cm) Depth
       (Square)                               7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth
 Weight:                                      1.8 lb (0.82 kg)
 Operating Temperature Range:                 -4°F to 158°F (-20°C to 70°C)
 Storage Temperature Range:                   –22°F to 158°F (–30°C to 70°C)
 Operating Humidity Range:                    0% to 95% relative humidity non-condensing
 Air Duct Velocity:                           100 to 4000 ft/min (0.5 to 20.32 m/sec)
 Electrical Ratings
 Power supply voltage:                  8.5-35 VDC
 Input capacitance:                     0.1 µF max.
 Reset voltage:                         2.5 VDC min.
 Reset time: (with RTS451)              0.03 to 0.3 sec.
 Reset time: (by power down)            0.3 sec. max.
 Power up time:                         35 sec. max.
 Alarm response time:                   15 sec.
 Sensitivity Test:                      See detector label
 Current Requirements: (Using No Accessories)
 Peak standby current:                  120µA
 Max. standby current:                  60 µA (average)
 Max. alarm current:                    130 mA
 Accessory Current Loads at 24 VDC
 Device                                 Standby                               Alarm
 RA100Z                                 0 mA                                  12 mA Max.
 RTS151                                 0 mA                                  12 mA Max.
 RTS151KEY                              12 mA                                 12 mA Max.




Installing the InnovairFlex Sampling Tube
The InnovairFlex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing
the front or rear locking tab (front locking tab shown below right).




A05-0421-002
Wiring for 2-wire Duct Smoke Detector
System wiring diagram for 2-wire duct smoke detectors (powered from initiating device circuit):


UL/FM LISTED
COMPATIBLE 2-WIRE           1ST DETECTOR                                 2ND DETECTOR                                 LAST DETECTOR
CONTROL PANEL               IN LOOP D2                                   IN LOOP D2                                   IN LOOP D2
                                                                                                                                                      EOL RESISTOR
                                                                                                                                                      SPECIFIED
                                                                                                                                                      BY PANEL
                                                                                                                                                      MANUFACTURER




                                                                                                    ~
                                                       ~




                                                                                                    ~
                                                       ~
            (+)
                            (+) IN   (+) OUT                             (+) IN   (+) OUT                             (+) IN   (+) OUT
                                               (+)                                          (+)                                          (+)
                                      (+) RA         RA100Z (OPTIONAL)             (+) RA         RA100Z (OPTIONAL)             (+) RA         RA100Z (OPTIONAL) E
ALARM                                                REMOTE ALARM LED                             REMOTE ALARM LED                             REMOTE ALARM LED O
                                                                                                                                                                 L
INITIATION                            (–) RA                                       (–) RA                                       (–) RA                           R
LOOP                                           (–)   4.4 VDC NOM.                           (–)   4.4 VDC NOM.                           (–)   4.4 VDC NOM.
                                                     IN ALARM                                     IN ALARM                                     IN ALARM
                                      (–)                                          (–)                                          (–)




                                                                                                    ~
                                                       ~




                                                                                                    ~
            (–)                                        ~
                                                      STYLE D OPTIONAL WIRING




Wiring diagram for 2-wire duct smoke detector to RTS151/RTS151KEY Remote Test Station



                  4                                                                                                                                          + TEST COIL
                                        + TEST COIL
 MAGNET                                                                                              24 VDC                      4
 TEST                                                             24 VDC                          AUX POWER        MAGNET
 SWITCH                                 – TEST COIL            AUX POWER                                                                                     – TEST COIL
                                                         (–)                                       SUPPLIED        TEST
                  5                                             SUPPLIED                           BY USER         SWITCH
                                                                BY USER                              (100mA
                                                         (+)      (100mA                                                         5                           + IN
                  2                     + IN                                                        SUPPLY)
                      (–)                                        SUPPLY)
                                                                                                                                 2                           + OUT
                                        + OUT
ALARM                                                       24 VAC (+10%, –15%)           24 VAC (+10%, –15%)                            (–)
LED (RED)             (+)                                  FULL WAVE RECTIFIED,          FULL WAVE RECTIFIED,
                  1                     –                   UNFILTERED POWER              UNFILTERED POWER                                                   –
                                                                                                                   ALARM
                                                               MAY BE USED                   MAY BE USED           LED (RED)     1       (+)
                                        – RA                                                                                                                 – RA

 RTS151/RTS151KEY                                                                                                 RTS151/RTS151KEY                           + RA
(OPTIONAL) REMOTE                       + RA
                                                                                                                 (OPTIONAL) REMOTE
   TEST STATION                                                                                                     TEST STATION                             + RTS
                                        + RTS

                               D2                                                                                                                                D2
     METHOD #1 - AUX POWER LOCATED                                                                               METHOD #2 - AUX POWER LOCATED
          AT DUCT DETECTOR                                                                                              AT TEST STATION

    NOTE: THE USE OF EITHER THE RTS151 OR RTS151KEY REQUIRES THE INSTALLATION OF AN ACCESSORY COIL, DCOIL, SOLD
                                   SEPARATELY. SEE FIGURE 9 ABOVE FOR REFERENCE.
Important Note
The use of either RTS151 or RTS151KEY requires the installation of an accessory coil, DCOIL, sold separately.
Please refer to the D2 installation manual for more information




                                                                                                                                                                    A05-0421-002
Accessories
System Sensor provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and
audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL listed.




                RTS151 UL S2522                                         RTS151KEY UL S2522                                  RA100Z UL S2522




Ordering Information
Part No.              Description
D2                    2-wire photoelectric low-flow duct smoke detector
Accessories
2151                  2-wire conventional photoelectric sensor head                  DH400OE-1   Weatherproof enclosure
DCOIL                 2-wire remote test coil required with RTS451/RTS451KEY         ETX         Metal exhaust tube duct width 1ft (0.3m)
DST1                  Metal sampling tube duct width up to 1ft (0.3m)                M02-04-00   Test magnet
DST1.5                Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m)    P48-21-00   End cap for metal sampling tubes
DST3                  Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 1.2 m)    RA100Z      Remote annunciator alarm LED
DST5                  Metal sampling tube duct widths 4 ft to 8 ft (1.2 to 2.4 m)    RTS151      Remote test station
DST10                 Metal sampling tube duct widths 8 ft to 12 ft (2.4 to 3.7 m)   RTS151KEY   Remote test station with key lock



                                                                                                                                  ©2010 System Sensor.
                                                    3825 Ohio Avenue • St. Charles, IL 60174        Product specifications subject to change without notice. Visit systemsensor.com for
                                                                                                        current product information, including the latest version of this data sheet.
                                                    Phone: 800-SENSOR2 • Fax: 630-377-6495                                     A05-0421-002 • 9/10 • #2498

Contenu connexe

Tendances

Apostila CEFET - Instalações Elétricas
Apostila CEFET - Instalações ElétricasApostila CEFET - Instalações Elétricas
Apostila CEFET - Instalações Elétricas
Fermi Xalegre
 
Neutral grounding resistor
Neutral grounding resistorNeutral grounding resistor
Neutral grounding resistor
Nithin Kumar K S
 
Docslide.com.br curso clp-exercicios-propostos
Docslide.com.br curso clp-exercicios-propostosDocslide.com.br curso clp-exercicios-propostos
Docslide.com.br curso clp-exercicios-propostos
Ivanir Silva
 
Cable Tray Installation 211215
Cable Tray Installation 211215Cable Tray Installation 211215
Cable Tray Installation 211215
MUHAMMAD MAJID
 

Tendances (20)

INSULATORS AND ITS TYPES
INSULATORS AND ITS TYPESINSULATORS AND ITS TYPES
INSULATORS AND ITS TYPES
 
Circuit Breaker and its types
Circuit Breaker and its typesCircuit Breaker and its types
Circuit Breaker and its types
 
Electromagnetic bomb
Electromagnetic bombElectromagnetic bomb
Electromagnetic bomb
 
Apostila CEFET - Instalações Elétricas
Apostila CEFET - Instalações ElétricasApostila CEFET - Instalações Elétricas
Apostila CEFET - Instalações Elétricas
 
Lightning, Surge Protection & Earthing of Electrical & Electronic Systems in ...
Lightning, Surge Protection & Earthing of Electrical & Electronic Systems in ...Lightning, Surge Protection & Earthing of Electrical & Electronic Systems in ...
Lightning, Surge Protection & Earthing of Electrical & Electronic Systems in ...
 
E bomb
E bombE bomb
E bomb
 
Smart Solar Grass Cutter Robot
Smart Solar Grass Cutter RobotSmart Solar Grass Cutter Robot
Smart Solar Grass Cutter Robot
 
The E-Bomb
The E-BombThe E-Bomb
The E-Bomb
 
IndoDivert™ - Bird Flight Diverter
IndoDivert™ - Bird Flight DiverterIndoDivert™ - Bird Flight Diverter
IndoDivert™ - Bird Flight Diverter
 
Airware for Drones
Airware for DronesAirware for Drones
Airware for Drones
 
Lightning Protection
Lightning ProtectionLightning Protection
Lightning Protection
 
Directed Energy Weapons 1/2
Directed Energy Weapons 1/2Directed Energy Weapons 1/2
Directed Energy Weapons 1/2
 
Neutral grounding resistor
Neutral grounding resistorNeutral grounding resistor
Neutral grounding resistor
 
Electric instalation operation and training manual
Electric instalation operation and training manualElectric instalation operation and training manual
Electric instalation operation and training manual
 
Redes industriais aula-1
Redes industriais aula-1Redes industriais aula-1
Redes industriais aula-1
 
Docslide.com.br curso clp-exercicios-propostos
Docslide.com.br curso clp-exercicios-propostosDocslide.com.br curso clp-exercicios-propostos
Docslide.com.br curso clp-exercicios-propostos
 
Cable Tray Installation 211215
Cable Tray Installation 211215Cable Tray Installation 211215
Cable Tray Installation 211215
 
Smart Grid & WAMS
Smart Grid & WAMSSmart Grid & WAMS
Smart Grid & WAMS
 
Spda
SpdaSpda
Spda
 
ADMS (Advanced Distribution Management System)
ADMS (Advanced Distribution Management System)ADMS (Advanced Distribution Management System)
ADMS (Advanced Distribution Management System)
 

En vedette

How to estimate the cost of a commercial fire alarm system
How to estimate the cost of a commercial fire alarm systemHow to estimate the cost of a commercial fire alarm system
How to estimate the cost of a commercial fire alarm system
Robert Tranford
 
2010 - Statistics of EU nationals registering and working in Malta
2010 - Statistics of EU nationals registering and working in Malta2010 - Statistics of EU nationals registering and working in Malta
2010 - Statistics of EU nationals registering and working in Malta
trESS Network
 
La1 uw24 x column loudspeakers
La1 uw24 x column loudspeakersLa1 uw24 x column loudspeakers
La1 uw24 x column loudspeakers
sanzen enterprises
 
Giornata Oasi "Torrente Chisone" Villar Perosa
Giornata Oasi "Torrente Chisone" Villar PerosaGiornata Oasi "Torrente Chisone" Villar Perosa
Giornata Oasi "Torrente Chisone" Villar Perosa
wwfpinerolese
 
100 comment win xp
100 comment win xp100 comment win xp
100 comment win xp
Nie Andini
 
Microsoft word bab 1 tahap 1 5
Microsoft word   bab 1 tahap 1 5Microsoft word   bab 1 tahap 1 5
Microsoft word bab 1 tahap 1 5
Nie Andini
 
Biographie
BiographieBiographie
Biographie
cawslide
 
Belajar membuat website
Belajar membuat websiteBelajar membuat website
Belajar membuat website
Nie Andini
 
Microsoft word proposal game battle ship online 1 3
Microsoft word   proposal game battle ship online 1 3Microsoft word   proposal game battle ship online 1 3
Microsoft word proposal game battle ship online 1 3
Nie Andini
 
Berenschot - Best Practices Duurzame Ontwikkeling
Berenschot - Best Practices Duurzame OntwikkelingBerenschot - Best Practices Duurzame Ontwikkeling
Berenschot - Best Practices Duurzame Ontwikkeling
mverheijen
 
Microlatch product review pac-15
Microlatch product review   pac-15Microlatch product review   pac-15
Microlatch product review pac-15
sanzen enterprises
 
Lessen Trekken Uit Het Verleden Om Uw Return Te Verhogen
Lessen Trekken Uit Het Verleden Om Uw Return Te VerhogenLessen Trekken Uit Het Verleden Om Uw Return Te Verhogen
Lessen Trekken Uit Het Verleden Om Uw Return Te Verhogen
Horatius Vermogensbeheer NV
 

En vedette (20)

How to estimate the cost of a commercial fire alarm system
How to estimate the cost of a commercial fire alarm systemHow to estimate the cost of a commercial fire alarm system
How to estimate the cost of a commercial fire alarm system
 
Lbc 395111
Lbc 395111Lbc 395111
Lbc 395111
 
Gallo presentation on Voicethreads
Gallo presentation on VoicethreadsGallo presentation on Voicethreads
Gallo presentation on Voicethreads
 
2010 - Statistics of EU nationals registering and working in Malta
2010 - Statistics of EU nationals registering and working in Malta2010 - Statistics of EU nationals registering and working in Malta
2010 - Statistics of EU nationals registering and working in Malta
 
Honeywell hus xact_4_0_ds
Honeywell hus xact_4_0_dsHoneywell hus xact_4_0_ds
Honeywell hus xact_4_0_ds
 
La1 uw24 x column loudspeakers
La1 uw24 x column loudspeakersLa1 uw24 x column loudspeakers
La1 uw24 x column loudspeakers
 
Sncrx
SncrxSncrx
Sncrx
 
Zouti Kanpay
Zouti KanpayZouti Kanpay
Zouti Kanpay
 
Giornata Oasi "Torrente Chisone" Villar Perosa
Giornata Oasi "Torrente Chisone" Villar PerosaGiornata Oasi "Torrente Chisone" Villar Perosa
Giornata Oasi "Torrente Chisone" Villar Perosa
 
James Warren From Webershandwick
James Warren From WebershandwickJames Warren From Webershandwick
James Warren From Webershandwick
 
100 comment win xp
100 comment win xp100 comment win xp
100 comment win xp
 
Microsoft word bab 1 tahap 1 5
Microsoft word   bab 1 tahap 1 5Microsoft word   bab 1 tahap 1 5
Microsoft word bab 1 tahap 1 5
 
Biographie
BiographieBiographie
Biographie
 
List str.2
List str.2List str.2
List str.2
 
Belajar membuat website
Belajar membuat websiteBelajar membuat website
Belajar membuat website
 
1 office, word
1 office, word1 office, word
1 office, word
 
Microsoft word proposal game battle ship online 1 3
Microsoft word   proposal game battle ship online 1 3Microsoft word   proposal game battle ship online 1 3
Microsoft word proposal game battle ship online 1 3
 
Berenschot - Best Practices Duurzame Ontwikkeling
Berenschot - Best Practices Duurzame OntwikkelingBerenschot - Best Practices Duurzame Ontwikkeling
Berenschot - Best Practices Duurzame Ontwikkeling
 
Microlatch product review pac-15
Microlatch product review   pac-15Microlatch product review   pac-15
Microlatch product review pac-15
 
Lessen Trekken Uit Het Verleden Om Uw Return Te Verhogen
Lessen Trekken Uit Het Verleden Om Uw Return Te VerhogenLessen Trekken Uit Het Verleden Om Uw Return Te Verhogen
Lessen Trekken Uit Het Verleden Om Uw Return Te Verhogen
 

Similaire à D2

Honeywell 5808w3-data-sheet
Honeywell 5808w3-data-sheetHoneywell 5808w3-data-sheet
Honeywell 5808w3-data-sheet
Alarm Grid
 
Honeywell 5806w3-data-sheet
Honeywell 5806w3-data-sheetHoneywell 5806w3-data-sheet
Honeywell 5806w3-data-sheet
Alarm Grid
 
4351 e hightempthermaldetector
4351 e hightempthermaldetector4351 e hightempthermaldetector
4351 e hightempthermaldetector
sanzen enterprises
 

Similaire à D2 (20)

Dnr
DnrDnr
Dnr
 
System Sensor 2151 Data Sheet
System Sensor 2151 Data SheetSystem Sensor 2151 Data Sheet
System Sensor 2151 Data Sheet
 
Industrial vli datasheet
Industrial vli datasheetIndustrial vli datasheet
Industrial vli datasheet
 
Honeywell 5808w3-data-sheet
Honeywell 5808w3-data-sheetHoneywell 5808w3-data-sheet
Honeywell 5808w3-data-sheet
 
Integrated Flame Scanner For Commercial and Industrial Combustion Operations
Integrated Flame Scanner For Commercial and Industrial Combustion OperationsIntegrated Flame Scanner For Commercial and Industrial Combustion Operations
Integrated Flame Scanner For Commercial and Industrial Combustion Operations
 
Integrated Flame Scanner for Industrial Combustion Operations
Integrated Flame Scanner for Industrial Combustion OperationsIntegrated Flame Scanner for Industrial Combustion Operations
Integrated Flame Scanner for Industrial Combustion Operations
 
Optical smokedetectoreco1003
Optical smokedetectoreco1003Optical smokedetectoreco1003
Optical smokedetectoreco1003
 
Sensepoint_Pro_pdf.pdf
Sensepoint_Pro_pdf.pdfSensepoint_Pro_pdf.pdf
Sensepoint_Pro_pdf.pdf
 
114 142 fire & security
114 142 fire & security114 142 fire & security
114 142 fire & security
 
Vlf250
Vlf250Vlf250
Vlf250
 
Honeywell 5806w3-data-sheet
Honeywell 5806w3-data-sheetHoneywell 5806w3-data-sheet
Honeywell 5806w3-data-sheet
 
G vlp 400 data sheet
G vlp 400 data sheetG vlp 400 data sheet
G vlp 400 data sheet
 
G vlp 400 data sheet
G vlp 400 data sheetG vlp 400 data sheet
G vlp 400 data sheet
 
Fire Safety Devices , Fire detection systems
Fire Safety Devices , Fire detection systems Fire Safety Devices , Fire detection systems
Fire Safety Devices , Fire detection systems
 
4351 e
4351 e4351 e
4351 e
 
4351 e hightempthermaldetector
4351 e hightempthermaldetector4351 e hightempthermaldetector
4351 e hightempthermaldetector
 
Sr
SrSr
Sr
 
ATI_Q46PR.pdf
ATI_Q46PR.pdfATI_Q46PR.pdf
ATI_Q46PR.pdf
 
A05 0182
A05 0182A05 0182
A05 0182
 
SenseTek Fireray 5000 datasheet
SenseTek Fireray 5000 datasheetSenseTek Fireray 5000 datasheet
SenseTek Fireray 5000 datasheet
 

Plus de sanzen enterprises (20)

Odyssey 3
Odyssey 3Odyssey 3
Odyssey 3
 
Vm3240va ce cb1e
Vm3240va ce cb1eVm3240va ce cb1e
Vm3240va ce cb1e
 
Vm 3240 e
Vm 3240 eVm 3240 e
Vm 3240 e
 
Sv200ma mi1e
Sv200ma mi1eSv200ma mi1e
Sv200ma mi1e
 
Sc610 cs1e
Sc610 cs1eSc610 cs1e
Sc610 cs1e
 
Sc610 cs1e
Sc610 cs1eSc610 cs1e
Sc610 cs1e
 
Cs154 cs1e
Cs154 cs1eCs154 cs1e
Cs154 cs1e
 
Bs678 cs1e tei rev1
Bs678 cs1e tei rev1Bs678 cs1e tei rev1
Bs678 cs1e tei rev1
 
Bs633a data sheet
Bs633a data sheetBs633a data sheet
Bs633a data sheet
 
Data sheet en_us_1902186891
Data sheet en_us_1902186891Data sheet en_us_1902186891
Data sheet en_us_1902186891
 
Data sheet en_us_1902186891
Data sheet en_us_1902186891Data sheet en_us_1902186891
Data sheet en_us_1902186891
 
Data sheet en_us_1911721995
Data sheet en_us_1911721995Data sheet en_us_1911721995
Data sheet en_us_1911721995
 
La1 uw24 x column loudspeakers
La1 uw24 x column loudspeakersLa1 uw24 x column loudspeakers
La1 uw24 x column loudspeakers
 
Bgt 4139 ts
Bgt 4139 tsBgt 4139 ts
Bgt 4139 ts
 
Bgt 5504 a
Bgt 5504 aBgt 5504 a
Bgt 5504 a
 
Bgt 5140 a
Bgt 5140 aBgt 5140 a
Bgt 5140 a
 
Bgt 9120 ts
Bgt 9120 tsBgt 9120 ts
Bgt 9120 ts
 
Bgt 9119 as
Bgt 9119 asBgt 9119 as
Bgt 9119 as
 
Bgt 720 tos
Bgt 720 tosBgt 720 tos
Bgt 720 tos
 
Bgt 5221 as
Bgt 5221 asBgt 5221 as
Bgt 5221 as
 

D2

  • 1. 2-Wire Photoelectric Duct Smoke Detector The InnovairFlex™ Series are the only duct smoke detectors flexible enough to fit configurations from square to rectangular and everything in between. Features The InnovairFlex D2 2-wire photoelectric duct smoke detector features a pivoting housing that fits various applications: both square • Photoelectric, integrated low-flow technology and rectangular footprints mount to round or rectangular duct work. • Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 m/sec) This new duct smoke detector senses airflow speeds ranging • Versatile mounting options in square or rectangular configuration from 100 to 4,000 feet per minute with proven System Sensor with modular construction precision. The enhancements built into this model improve false alarm immunity (with plug-in sensor head); broaden operating • Plug-in sensor temperature (−4°F to 158°F) and humidity (0 to 95 percent non- • Superb false alarm immunity with the latest sensor technology condensing) ranges; while simplifying installation and maintenance. • Broader ranges for operating temperature (−4°F to 158°F) and These advance features can detect smoke even in the harshest duct humidity (0% to 95% non-condensing) applications. • Patented sampling tube installs from front or back of the detector The new design provides more wiring space with an added ¾ inch with no tools required conduit knockout. Numbers and labels for terminal designations are • A cover tamper feature to indicate a trouble condition for removed consistent with previous Innovair models. The new sampling tube or improperly installed sensor cover can be clicked into position with one smooth motion from either the • Increased wiring space with a newly added ¾ inch conduit front or the back of the detector. knockout The InnovairFlex D2 duct smoke detector has signals to indicate • Improved LED status trouble and maintenance conditions. Additionally, a cover tamper • 24 VDC feature is incorporated to indicate a trouble condition for removed • Backward compatibility with existing Innovair products, including or improperly installed sensor cover. An improved cover design, with remote accessories an integrated the low-flow feature, isolates the sensor head from the low-flow technology for simple maintenance. The InnovairFlex series is designed for greater flexibility and reliable smoke detection to simplify installation and maintenance. The new InnovairFlex product line is backward compatible to existing Innovair models, including remote test accessories WARNING: Duct smoke detectors have specific limitations. Agency Listings DUCT SMOKE DETECTORS ARE: NOT a substitute for an open area smoke detector, NOT a substitute for early warning detection, and NOT a replacement for a building’s regular fire detection system. Refer to NFPA 72 and 90A for additional duct smoke detector S911 3029700 3242-1653:206 2202 application information.
  • 2. InnovairFlex Duct Smoke Detector Specifications Architectural/Engineering Specifications The air duct smoke detector shall be a System Sensor InnovairFlex™ D2 Photoelectric Duct Smoke Detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits both square and rectangular footprints. The detector shall operate at air velocities of 100 ft/min to 4000 ft/min (0.5 m/sec to 20.32 m/sec). The unit shall be capable of providing a trouble signal in the event that the sensor cover is removed or improperly installed. It shall be capable of local testing via magnetic switch or remote testing using the RTS451KEY remote test station. Terminal connections shall be of the strip and clamp method suitable for 12–18 AWG wiring. Physical Specifications Size: (Rectangular) 14.38 in (37 cm) Length; 5 in (12.7 cm) Width; 2.5 in (6.36 cm) Depth (Square) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 1.8 lb (0.82 kg) Operating Temperature Range: -4°F to 158°F (-20°C to 70°C) Storage Temperature Range: –22°F to 158°F (–30°C to 70°C) Operating Humidity Range: 0% to 95% relative humidity non-condensing Air Duct Velocity: 100 to 4000 ft/min (0.5 to 20.32 m/sec) Electrical Ratings Power supply voltage: 8.5-35 VDC Input capacitance: 0.1 µF max. Reset voltage: 2.5 VDC min. Reset time: (with RTS451) 0.03 to 0.3 sec. Reset time: (by power down) 0.3 sec. max. Power up time: 35 sec. max. Alarm response time: 15 sec. Sensitivity Test: See detector label Current Requirements: (Using No Accessories) Peak standby current: 120µA Max. standby current: 60 µA (average) Max. alarm current: 130 mA Accessory Current Loads at 24 VDC Device Standby Alarm RA100Z 0 mA 12 mA Max. RTS151 0 mA 12 mA Max. RTS151KEY 12 mA 12 mA Max. Installing the InnovairFlex Sampling Tube The InnovairFlex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking tab (front locking tab shown below right). A05-0421-002
  • 3. Wiring for 2-wire Duct Smoke Detector System wiring diagram for 2-wire duct smoke detectors (powered from initiating device circuit): UL/FM LISTED COMPATIBLE 2-WIRE 1ST DETECTOR 2ND DETECTOR LAST DETECTOR CONTROL PANEL IN LOOP D2 IN LOOP D2 IN LOOP D2 EOL RESISTOR SPECIFIED BY PANEL MANUFACTURER ~ ~ ~ ~ (+) (+) IN (+) OUT (+) IN (+) OUT (+) IN (+) OUT (+) (+) (+) (+) RA RA100Z (OPTIONAL) (+) RA RA100Z (OPTIONAL) (+) RA RA100Z (OPTIONAL) E ALARM REMOTE ALARM LED REMOTE ALARM LED REMOTE ALARM LED O L INITIATION (–) RA (–) RA (–) RA R LOOP (–) 4.4 VDC NOM. (–) 4.4 VDC NOM. (–) 4.4 VDC NOM. IN ALARM IN ALARM IN ALARM (–) (–) (–) ~ ~ ~ (–) ~ STYLE D OPTIONAL WIRING Wiring diagram for 2-wire duct smoke detector to RTS151/RTS151KEY Remote Test Station 4 + TEST COIL + TEST COIL MAGNET 24 VDC 4 TEST 24 VDC AUX POWER MAGNET SWITCH – TEST COIL AUX POWER – TEST COIL (–) SUPPLIED TEST 5 SUPPLIED BY USER SWITCH BY USER (100mA (+) (100mA 5 + IN 2 + IN SUPPLY) (–) SUPPLY) 2 + OUT + OUT ALARM 24 VAC (+10%, –15%) 24 VAC (+10%, –15%) (–) LED (RED) (+) FULL WAVE RECTIFIED, FULL WAVE RECTIFIED, 1 – UNFILTERED POWER UNFILTERED POWER – ALARM MAY BE USED MAY BE USED LED (RED) 1 (+) – RA – RA RTS151/RTS151KEY RTS151/RTS151KEY + RA (OPTIONAL) REMOTE + RA (OPTIONAL) REMOTE TEST STATION TEST STATION + RTS + RTS D2 D2 METHOD #1 - AUX POWER LOCATED METHOD #2 - AUX POWER LOCATED AT DUCT DETECTOR AT TEST STATION NOTE: THE USE OF EITHER THE RTS151 OR RTS151KEY REQUIRES THE INSTALLATION OF AN ACCESSORY COIL, DCOIL, SOLD SEPARATELY. SEE FIGURE 9 ABOVE FOR REFERENCE. Important Note The use of either RTS151 or RTS151KEY requires the installation of an accessory coil, DCOIL, sold separately. Please refer to the D2 installation manual for more information A05-0421-002
  • 4. Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL listed. RTS151 UL S2522 RTS151KEY UL S2522 RA100Z UL S2522 Ordering Information Part No. Description D2 2-wire photoelectric low-flow duct smoke detector Accessories 2151 2-wire conventional photoelectric sensor head DH400OE-1 Weatherproof enclosure DCOIL 2-wire remote test coil required with RTS451/RTS451KEY ETX Metal exhaust tube duct width 1ft (0.3m) DST1 Metal sampling tube duct width up to 1ft (0.3m) M02-04-00 Test magnet DST1.5 Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) P48-21-00 End cap for metal sampling tubes DST3 Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 1.2 m) RA100Z Remote annunciator alarm LED DST5 Metal sampling tube duct widths 4 ft to 8 ft (1.2 to 2.4 m) RTS151 Remote test station DST10 Metal sampling tube duct widths 8 ft to 12 ft (2.4 to 3.7 m) RTS151KEY Remote test station with key lock ©2010 System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. Phone: 800-SENSOR2 • Fax: 630-377-6495 A05-0421-002 • 9/10 • #2498