SlideShare une entreprise Scribd logo
1  sur  2
Télécharger pour lire hors ligne
Real-Time Dynamic Compensation for Static Pressure Effects
Performance under pressure - DP Transmitter Static pressure (SP) is applied equally to both the high-pressure side
and the low-pressure side of a DP transmitter and can vary the linear
Accurate measurement is vital to efficient plant operation and plant characteristics of the DP signal output. The effect is called Static
safety. When selecting a transmitter, a lot of attention is paid to the Pressure Effect . This characteristic has both Zero Effect and
Reference Accuracy noted in supplier's specification documents. Span Effect components.
Reference Accuracy gets its name because the accuracy is based
on a set of reference conditions. The reference conditions dictate
a certain temperature, humidity, and static pressure for the
Reference Accuracy to be measured in a laboratory setting. In the
real world, DP Transmitters are rarely installed in a laboratory
and never under the rigid confines of those reference conditions; therefore,
Real-world Performance (RWP) is always worse than the Reference
Accuracy. To improve RWP, all smart transmitters on the market SP Effect
compensate for variations in temperature; but, Yokogawa's sensor
used in the EJA-A series, EJX-A series, and EJX-B series is unique in
the market place because it can compensate for effects in static
pressure change as well. This ability is referred to 0% 100%
Real-time Dynamic Compensation .
Static Pressure Effects SP = 100
Using differential transmitters to measure flow and tank level are
examples of applications where variations in static pressure can effect 100 100 100 200
the differential pressure readings of a transmitter. 0%
SP = 0
0 0 0 100
0%
PTN1011.003a
To quantify the impact, Real-world Performance (RWP) can be
calculated per published specifications and process conditions. RWP is
a combined error of Reference Accuracy (E1), Temperature Effect (E2),
Static Pressure Zero Effect (E3) and Static Pressure Span Effect (E4).
Competitors state that the static pressure zero effect (E3) can be
PTN1011.001a zeroed at line static pressure during the setup of the transmitter.
In many flow measurements or process level applications, static
pressure is not maintained at a constant value. As operational
conditions change, the static pressure exerted on the DP transmitter
varies. Hence, the static pressure zero effect (E3) cannot always be
cancelled by zeroing at line static pressure during setup. This effect
cannot be neglected when evaluating the real-world performance.
Yokogawa's Full Dynamic Compensation
Yokogawa's silicon resonant sensor is a true multi-sensing platform.
It can measure differential pressure, static pressure, and temperature
in one compact sensor chip. This multi-sensing sensor allows
the transmitter to use correction coefficients stored in the sensor's
ROM to compensate for fluctuations in static pressure and
temperature to reduce the static pressure and temperature effects.
The correction coefficients are unique to each sensor and are
PTN1011.002a generated at the factory through rigorous testing (See Figure 1).
Page 1 of 2
LH.080111.01a PTN-1011 1st Edition 08/2011
LH.012711.a
Static Pressure Zero and Span Effect
Input (DP)
ERROR(%)
Flow Measurement
ΔP ≈ Flow²
Level Measurement
ΔP ≈ Process Level
E3: SP Zero Effect
E4: SP Span Effect
100%
100%
Field Instruments
www.yokogawa.com/us
Alternate Sensor Technology
Capacitive sensor technology used in the marketplace is not capable
of multi-sensing. It can only measure differential pressure. The DP
transmitters using this type of technology incorporate a resistive
temperature sensor near the capacitive sensor to compensate for
temperature fluctuations; but, they do not add a separate sensor to
measure static pressure for static pressure fluctuations. Therefore,
these transmitters are not capable of minimizing the static pressure
effect (See Figure 2).
Figure 1 Yokogawa's Multi-sensing Resonant Sensor Technology
Transmitter
Silicon
Resonant
Sensor
Figure 2 Capacitive Sensor Technology PTN1011.003a
Transmitter
Capacitive
Sensor
RTD
Not measured Static Pressure is not measured; therefore it is not compensated for.
PTN1011.004a
Figure 3 Comparison of Real-world Performance
Conclusion
Even in high static pressure applications, Yokogawa's EJA-A / EJX-A /
EJX-B series dramatically reduces the static pressure effects and provides
superior total performance. Using the published specifications, the Real-
world Performance can be calculated for comparative estimates
(See Figure 3). Note that the Reference Accuracy is the smallest component
of the calculations.
E1: Reference Accuracy Calibrated Span: 0 to 1500 inH ₂O
E2: Temperature Effect Static Pressure: 1,200 psig
E3: Static Pressure Zero Effect PTN1011.005a
E4: Static Pressure Span Effect Page 2 of 2
LH.080111.01a PTN-1011 1st Edition 08/2011
Process
Process
www.yokogawa.com/us
Field Instruments
Correction Coefficients
Dynamic Compensation
Temperature Effect
&
Static Pressure Effect
Primary Variable:
Dynamic Compensated
DP Signal
(4 to 20 mA)
Differential Pressure
Differential Pressure
Temperature Temperature
Static Pressure Static Pressure
Differential Pressure
Temperature
Static Pressure
Differential Pressure
Temperature
Temperature
Correction Coefficients
Temperature Effect
Compensation
Digital /Analog
Conversion
Secondary Variable:
Static Pressure
(Digital Protocol)
Third Variable:
Capsule Temperature
(Digital Protocol)
Digital /Analog
Conversion
Analog /Digital
Conversion
Primary Variable:
Temperature Compensated
DP Signal
(4 to 20 mA)
Secondary Variable:
Temperature
(Digital Protocol)
EJX110A
EJA110A
Capacitive
Sensor
Transmitter
RWP = E1+E2+E3+E4
0.0% 0.5% 1.0% 1.5% 2.0% 2.5%

Contenu connexe

En vedette

Project Pelican Pulse Oximeter Presentations
Project Pelican Pulse Oximeter PresentationsProject Pelican Pulse Oximeter Presentations
Project Pelican Pulse Oximeter Presentations
Léah Chung
 
Handbook For Process Plant Project Engineers - Peter Watermeyer
Handbook For Process Plant Project Engineers - Peter WatermeyerHandbook For Process Plant Project Engineers - Peter Watermeyer
Handbook For Process Plant Project Engineers - Peter Watermeyer
Veerender Putta
 

En vedette (10)

Pelican Pulse Oximeter
Pelican Pulse OximeterPelican Pulse Oximeter
Pelican Pulse Oximeter
 
Yokogawa Differential Pressure Transmitter
Yokogawa Differential Pressure TransmitterYokogawa Differential Pressure Transmitter
Yokogawa Differential Pressure Transmitter
 
Instrumentation measurement principles
Instrumentation  measurement principlesInstrumentation  measurement principles
Instrumentation measurement principles
 
The Internet of Everything: Tom Lee, Stanford School of Engineering
The Internet of Everything:  Tom Lee, Stanford School of EngineeringThe Internet of Everything:  Tom Lee, Stanford School of Engineering
The Internet of Everything: Tom Lee, Stanford School of Engineering
 
Cisco Internet of Things
Cisco Internet of ThingsCisco Internet of Things
Cisco Internet of Things
 
Project Pelican Pulse Oximeter Presentations
Project Pelican Pulse Oximeter PresentationsProject Pelican Pulse Oximeter Presentations
Project Pelican Pulse Oximeter Presentations
 
Fired Heater and Combustion Optimization From Yokogawa
Fired Heater and Combustion Optimization From YokogawaFired Heater and Combustion Optimization From Yokogawa
Fired Heater and Combustion Optimization From Yokogawa
 
Process Plant design fundementals
Process Plant design fundementalsProcess Plant design fundementals
Process Plant design fundementals
 
Handbook For Process Plant Project Engineers - Peter Watermeyer
Handbook For Process Plant Project Engineers - Peter WatermeyerHandbook For Process Plant Project Engineers - Peter Watermeyer
Handbook For Process Plant Project Engineers - Peter Watermeyer
 
Basic instrumentation
Basic instrumentationBasic instrumentation
Basic instrumentation
 

Plus de Miller Energy, Inc.

Plus de Miller Energy, Inc. (20)

Flow & Pressure Instrumentation for Biopharmaceuticals & Life Sciences
Flow & Pressure Instrumentation for Biopharmaceuticals & Life SciencesFlow & Pressure Instrumentation for Biopharmaceuticals & Life Sciences
Flow & Pressure Instrumentation for Biopharmaceuticals & Life Sciences
 
One Series Safety Transmitter - Pressure and Temperature Transmitter-Switch
One Series Safety Transmitter - Pressure and Temperature Transmitter-SwitchOne Series Safety Transmitter - Pressure and Temperature Transmitter-Switch
One Series Safety Transmitter - Pressure and Temperature Transmitter-Switch
 
Magnetrol Guide Wave Radar Level Transmitter For Hygienic Applications
Magnetrol Guide Wave Radar Level Transmitter For Hygienic ApplicationsMagnetrol Guide Wave Radar Level Transmitter For Hygienic Applications
Magnetrol Guide Wave Radar Level Transmitter For Hygienic Applications
 
Solenoid Valves for Water Conditioning and Purification Systems and Equipment
Solenoid Valves for Water Conditioning and Purification Systems and EquipmentSolenoid Valves for Water Conditioning and Purification Systems and Equipment
Solenoid Valves for Water Conditioning and Purification Systems and Equipment
 
Special RTD Temperature Sensor Configuration for Heat Trace Applications
Special RTD Temperature Sensor Configuration for Heat Trace ApplicationsSpecial RTD Temperature Sensor Configuration for Heat Trace Applications
Special RTD Temperature Sensor Configuration for Heat Trace Applications
 
Maintenance Procedures for Yokogawa ADMAG TI Series AXW Magnetic Flow Meter
Maintenance Procedures for Yokogawa ADMAG TI Series AXW Magnetic Flow MeterMaintenance Procedures for Yokogawa ADMAG TI Series AXW Magnetic Flow Meter
Maintenance Procedures for Yokogawa ADMAG TI Series AXW Magnetic Flow Meter
 
Asco Safety Systems Solenoid Valve Selection Guide
Asco Safety Systems Solenoid Valve Selection GuideAsco Safety Systems Solenoid Valve Selection Guide
Asco Safety Systems Solenoid Valve Selection Guide
 
Eclipse Model 706 High Performance Guided Wave Radar Level Transmitter
Eclipse Model 706 High Performance Guided Wave Radar Level TransmitterEclipse Model 706 High Performance Guided Wave Radar Level Transmitter
Eclipse Model 706 High Performance Guided Wave Radar Level Transmitter
 
Schubert & Salzer Product Overview
Schubert & Salzer Product OverviewSchubert & Salzer Product Overview
Schubert & Salzer Product Overview
 
Mass Flow Controller - Quantim Series
Mass Flow Controller - Quantim SeriesMass Flow Controller - Quantim Series
Mass Flow Controller - Quantim Series
 
RACO Verbation Alarm Monitoring System Schematic
RACO Verbation Alarm Monitoring System SchematicRACO Verbation Alarm Monitoring System Schematic
RACO Verbation Alarm Monitoring System Schematic
 
Quick Coupling Products Guide - Commercial & Industrial
Quick Coupling Products Guide - Commercial & IndustrialQuick Coupling Products Guide - Commercial & Industrial
Quick Coupling Products Guide - Commercial & Industrial
 
Temperature, Pressure, Vacuum, and Differential Switches
Temperature, Pressure, Vacuum, and Differential SwitchesTemperature, Pressure, Vacuum, and Differential Switches
Temperature, Pressure, Vacuum, and Differential Switches
 
Current to Pneumatic Converter
Current to Pneumatic ConverterCurrent to Pneumatic Converter
Current to Pneumatic Converter
 
WirelessHART Gas Detector for Toxic and Combustible Gas
WirelessHART Gas Detector for Toxic and Combustible GasWirelessHART Gas Detector for Toxic and Combustible Gas
WirelessHART Gas Detector for Toxic and Combustible Gas
 
Life Science Applications and Products - Magnetrol
Life Science Applications and Products - MagnetrolLife Science Applications and Products - Magnetrol
Life Science Applications and Products - Magnetrol
 
Pump Protection Using Thermal Dispersion Switches
Pump Protection Using Thermal Dispersion SwitchesPump Protection Using Thermal Dispersion Switches
Pump Protection Using Thermal Dispersion Switches
 
Metal Tube Variable Area Flow Meter
Metal Tube Variable Area Flow MeterMetal Tube Variable Area Flow Meter
Metal Tube Variable Area Flow Meter
 
Industrial Valves for Gas Distribution, CNG, LNG
Industrial Valves for Gas Distribution, CNG, LNGIndustrial Valves for Gas Distribution, CNG, LNG
Industrial Valves for Gas Distribution, CNG, LNG
 
Magnetrol Non-Contact Radar Level Transmitter Pulsar R86
Magnetrol Non-Contact Radar Level Transmitter Pulsar R86Magnetrol Non-Contact Radar Level Transmitter Pulsar R86
Magnetrol Non-Contact Radar Level Transmitter Pulsar R86
 

Dernier

Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Christo Ananth
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
dharasingh5698
 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
dollysharma2066
 
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night StandCall Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
amitlee9823
 

Dernier (20)

(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.ppt
 
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
 
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptxBSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - V
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPT
 
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
 
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night StandCall Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
 
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
 
Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01
 
Thermal Engineering Unit - I & II . ppt
Thermal Engineering  Unit - I & II . pptThermal Engineering  Unit - I & II . ppt
Thermal Engineering Unit - I & II . ppt
 
Unleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leapUnleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leap
 
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
 
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
 

Dynamic Compensation for Static Pressure Effects in Differential Pressure Measurement

  • 1. Real-Time Dynamic Compensation for Static Pressure Effects Performance under pressure - DP Transmitter Static pressure (SP) is applied equally to both the high-pressure side and the low-pressure side of a DP transmitter and can vary the linear Accurate measurement is vital to efficient plant operation and plant characteristics of the DP signal output. The effect is called Static safety. When selecting a transmitter, a lot of attention is paid to the Pressure Effect . This characteristic has both Zero Effect and Reference Accuracy noted in supplier's specification documents. Span Effect components. Reference Accuracy gets its name because the accuracy is based on a set of reference conditions. The reference conditions dictate a certain temperature, humidity, and static pressure for the Reference Accuracy to be measured in a laboratory setting. In the real world, DP Transmitters are rarely installed in a laboratory and never under the rigid confines of those reference conditions; therefore, Real-world Performance (RWP) is always worse than the Reference Accuracy. To improve RWP, all smart transmitters on the market SP Effect compensate for variations in temperature; but, Yokogawa's sensor used in the EJA-A series, EJX-A series, and EJX-B series is unique in the market place because it can compensate for effects in static pressure change as well. This ability is referred to 0% 100% Real-time Dynamic Compensation . Static Pressure Effects SP = 100 Using differential transmitters to measure flow and tank level are examples of applications where variations in static pressure can effect 100 100 100 200 the differential pressure readings of a transmitter. 0% SP = 0 0 0 0 100 0% PTN1011.003a To quantify the impact, Real-world Performance (RWP) can be calculated per published specifications and process conditions. RWP is a combined error of Reference Accuracy (E1), Temperature Effect (E2), Static Pressure Zero Effect (E3) and Static Pressure Span Effect (E4). Competitors state that the static pressure zero effect (E3) can be PTN1011.001a zeroed at line static pressure during the setup of the transmitter. In many flow measurements or process level applications, static pressure is not maintained at a constant value. As operational conditions change, the static pressure exerted on the DP transmitter varies. Hence, the static pressure zero effect (E3) cannot always be cancelled by zeroing at line static pressure during setup. This effect cannot be neglected when evaluating the real-world performance. Yokogawa's Full Dynamic Compensation Yokogawa's silicon resonant sensor is a true multi-sensing platform. It can measure differential pressure, static pressure, and temperature in one compact sensor chip. This multi-sensing sensor allows the transmitter to use correction coefficients stored in the sensor's ROM to compensate for fluctuations in static pressure and temperature to reduce the static pressure and temperature effects. The correction coefficients are unique to each sensor and are PTN1011.002a generated at the factory through rigorous testing (See Figure 1). Page 1 of 2 LH.080111.01a PTN-1011 1st Edition 08/2011 LH.012711.a Static Pressure Zero and Span Effect Input (DP) ERROR(%) Flow Measurement ΔP ≈ Flow² Level Measurement ΔP ≈ Process Level E3: SP Zero Effect E4: SP Span Effect 100% 100% Field Instruments www.yokogawa.com/us
  • 2. Alternate Sensor Technology Capacitive sensor technology used in the marketplace is not capable of multi-sensing. It can only measure differential pressure. The DP transmitters using this type of technology incorporate a resistive temperature sensor near the capacitive sensor to compensate for temperature fluctuations; but, they do not add a separate sensor to measure static pressure for static pressure fluctuations. Therefore, these transmitters are not capable of minimizing the static pressure effect (See Figure 2). Figure 1 Yokogawa's Multi-sensing Resonant Sensor Technology Transmitter Silicon Resonant Sensor Figure 2 Capacitive Sensor Technology PTN1011.003a Transmitter Capacitive Sensor RTD Not measured Static Pressure is not measured; therefore it is not compensated for. PTN1011.004a Figure 3 Comparison of Real-world Performance Conclusion Even in high static pressure applications, Yokogawa's EJA-A / EJX-A / EJX-B series dramatically reduces the static pressure effects and provides superior total performance. Using the published specifications, the Real- world Performance can be calculated for comparative estimates (See Figure 3). Note that the Reference Accuracy is the smallest component of the calculations. E1: Reference Accuracy Calibrated Span: 0 to 1500 inH ₂O E2: Temperature Effect Static Pressure: 1,200 psig E3: Static Pressure Zero Effect PTN1011.005a E4: Static Pressure Span Effect Page 2 of 2 LH.080111.01a PTN-1011 1st Edition 08/2011 Process Process www.yokogawa.com/us Field Instruments Correction Coefficients Dynamic Compensation Temperature Effect & Static Pressure Effect Primary Variable: Dynamic Compensated DP Signal (4 to 20 mA) Differential Pressure Differential Pressure Temperature Temperature Static Pressure Static Pressure Differential Pressure Temperature Static Pressure Differential Pressure Temperature Temperature Correction Coefficients Temperature Effect Compensation Digital /Analog Conversion Secondary Variable: Static Pressure (Digital Protocol) Third Variable: Capsule Temperature (Digital Protocol) Digital /Analog Conversion Analog /Digital Conversion Primary Variable: Temperature Compensated DP Signal (4 to 20 mA) Secondary Variable: Temperature (Digital Protocol) EJX110A EJA110A Capacitive Sensor Transmitter RWP = E1+E2+E3+E4 0.0% 0.5% 1.0% 1.5% 2.0% 2.5%