7.
8.
9. TOUCHART – One ZONE SWITCH
TA 101
Technical Manual
Specifications:
Supply voltage : 90 - 250V/AC
Supply frequency : 50-60 Hz
Number of switching zone : 1
Load per switching zone : 1000W resistive or 300W inductive Lamps or
4 fittings of fluorescent Lamps
Power consumption of wall unit : < 10 mw
Operating Temperature : -10°C to 55°C
WIRING DIAGRAM (REAR VIEW)
TOYAMA
TA 101
NEUTRAL
PHASE
LOAD 1
BLACK
BLUE
RED
NOTE:
Always Use
60mm Depth
Metal Boxes.
220V AC
Note: Use 1.5 Sq.mm. flexible wires for connections (Phase, Neutral & Load)
Mounting Metal box for the Device - 2 Module (75mmX75mmX60mm)
10. TOUCHART POWER SWITCH for AC,Geyser,..
TA 101A
Technical Manual
Specifications:
Supply voltage : 90 - 250V/AC
Supply frequency : 50-60 Hz
Number of switching zones : 1
Load per switching zone : 20A
Power consumption of wall unit : < 10 mw
Operating Temperature : -10°C to 55°C
WIRING DIAGRAM OF TOUCHART POWER SWITCH (REAR VIEW)
TOYAMA
TA 101A
NEUTRAL
PHASE
LOAD 1
BLACK
RED
BLUE
NOTE:
Always Use
60mm Depth
Metal Boxes.
220V AC
Note: Use 2.5 Sq.mm. Flexible wires for connections (Phase, Neutral & Load)
Mounting Metal box for the Device - 2 Module (75mmX75mmX60mm)
11. TOUCHART – BELL SWITCH
TA 101B
Technical Manual
Specifications:
Supply voltage : 90 - 250V/AC
Supply frequency : 50-60 Hz
Number of zones : 1 Bell
Power consumption of wall unit : < 10 mw
Operating Temperature : -10°C to 55°C
WIRING DIAGRAM (REAR VIEW)
TOYAMA
TA 101B
NEUTRAL
PHASE
BELL
RED
BLACK
BLUE
NOTE:
Always Use
60mm Depth
Metal Boxes.
220V AC
Note: Use 1.5 Sq.mm. flexible wires for connections (Phase, Neutral & Load)
Mounting Metal box for the Device - 2 Module (75mmX75mmX60mm)
12. TOUCHART – TWO WAY SWITCH
TA 101 T
Technical Manual
Specifications:
Supply voltage : 90 - 250V/AC
Supply frequency : 50-60 Hz
Number of switching zone : 1
Load per switching zone : 1000W resistive or 300W inductive Lamps or
4 fittings of fluorescent Lamps
Power consumption of wall unit : < 10 mw
Operating Temperature : -10°C to 55°C
WIRING DIAGRAM (REAR VIEW)
SWITCH-1 SWITCH-2
TOYAMA
TOYAMA
TA 101T TA 101T
NEUTRAL
NEUTRAL
PHASE IN
PHASE
PHASE
LOAD
NO
NC
NO
NC
NOTE:
Always Use
60mm Depth
Metal Boxes.
YELLOW
YELLOW
RED
BLACK
BLUE
BLUE
RED
BLACK
BLUE
BLUE
220V AC 220V AC
Note: Use 1.5 Sq.mm. flexible wires for connections (Phase, Neutral & Load)
Mounting Metal box for the Device - 2 Module (75mmX75mmX60mm)
13. TOUCHART - 2 ZONE SWITCH
TA 102
Technical Manual
Specifications:
Supply voltage : 90 - 250V/AC
Supply frequency : 50-60 Hz
Number of switching zones : 2
Load per switching zone : 5A
Power consumption of wall unit : < 10 mw
Operating Temperature : -10°C to 55°C
WIRING DIAGRAM (REAR VIEW)
TOYAMA
TA 102
NEUTRAL
LOAD 1
PHASE
LOAD 2
BLACK
RED
BLUE
BLUE
NOTE:
Always Use
60mm Depth
Metal Boxes.
220V AC
Note: Use 1.5 Sq.mm.flexible wires for connections (Phase, Neutral & Load)
Mounting Metal box for the Device - 2 Module (75mmX75mmX60mm)
14. TOUCHART DIMMER One Zone
TA 301
Technical Manual
Specifications:
Supply voltage : 90 - 250V/AC
Supply frequency : 50-60 Hz
Number of dimming zone : 1
Load per regulating/dimming zone : 200W of GLS or 100W of Halogen lamps or 1 fan
Power consumption of wall unit : < 10 mw
Operating Temperature : -10°C to 55°C
WIRING DIAGRAM (REAR VIEW)
TOYAMA
TA 301
NEUTRAL
PHASE
LOAD
RED
BLACK
BLUE
NOTE:
Always Use
60mm Depth
Metal Boxes.
220V AC
Note: Use 1.5 Sq.mm. flexible wires for connections (Phase, Neutral & Load)
Mounting Metal box for the Device - 2 Module (75mmX75mmX60mm)
15. TOUCHART CURTAIN SWITCH -1 Zone
TA 502
Installation Manual
Specifications:
Supply voltage : 90 - 250V/AC
Supply frequency : 50-60 Hz
Number of Curtain zones : 1 (Open, Close & Stop)
Power consumption of wall unit : < 10 mw
Operating Temperature : -10°C to 55°C
Wiring Diagram (Rear View)
TOYAMA
TA 502
NEUTRAL
C-CLOSE
C-OPEN
PHASE
RED
BLACK
BLUE
BLUE
NOTE:
Always Use
60mm Depth
Metal Boxes.
220V AC
Note: Use 1.5 Sq.mm. flexible wires for Phase, Neutral & Load connections
Mounting Metal box for the Device - 4 Module (75mmX140mmX60mm)
16. Hotel TouchArt Corridor Panel -Direct
TH 413LD
Technical Manual
Specifications:
Supply voltage : 90 - 250V/AC
Supply frequency : 50-60 Hz
Corridor Panel (indicator icons) :“Privacy” “Clean My Room” “Laundry” & “BELL”
Operating Temperature : -10°C to +50°C
Dissipation power : <10mW
Wiring diagram: (Rear View)
Common
Laundry
Privacy
CMR
SWITCH PANEL
(Bed Side)
NOTE: BLACK
YELLOW
RED
BLUE
Always Use
60mm Depth
Metal Boxes.
4Core Cable
TH 413LD
NEUTRAL
PHASE
BELL
BLUE
BLACK
RED
220V AC
Note: Use 1.5 Sq.mm. flexible wires for Phase, Neutral & Load connections
Mounting Metal box for the Devices - 2 Module (75mmX75mmX60mm)
17. Hotel Corridor & Service panels
TH 413L + TH 403L
Technical Manual
Specifications:
Corridor Panel:
Supply voltage : 90 - 250V/AC
Supply frequency : 50-60 Hz
Corridor Panel (indicator icons) : “Do not disturb” , “Clean My Room”, “Laundry” & “DoorBell”
Operating Temperature : -10°C to +50°C
Dissipation power : <10mW
Service Panel:
Service Panel (indicator icons) : “Do not disturb” , “Clean My Room” & “Laundry”
Dimension : W90mmXH90mmXD40mm
Wiring diagram: (Rear View)
CAT5 Cable
YELLOW
YELLOW
BLACK
BLACK
BLUE
BLUE
RED
RED
TOYAMA
TOYAMA
4Core Cable
4Core Cable
TH 413L TH 403L
NEUTRAL
PHASE
BELL
BLUE
BLACK
RED
NOTE:
Always Use
60mm Depth
Metal Boxes.
220V AC
Note: Use 1.5 Sq.mm. flexible wires for Phase, Neutral & Load connections
Mounting Metal box for the Devices - 2 Module (75mmX75mmX60mm)
18. TOUCHART Remote Switch - 4 Zone
TA 104
Installation Manual
Specifications:
Supply voltage : 90 - 250V/AC
Supply frequency : 50-60 Hz
Number of switching zones : 4
Load per switching zone : 1000W resistive or 300W inductive Lamps or
4 fittings of fluorescent Lamps
Remote operating angle : 140°
Remote operating distance straight : 25 feet
Power consumption of wall unit : < 10 mw
Operating Temperature : -10°C to 55°C
Wiring Diagram (Rear View)
TOYAMA
RED NOTE:
PHASE IN
Always Use
BLUE L1 TA 104 60mm Depth
Metal Boxes.
BLUE L2
L3
BLUE
L4
BLUE
NEUTRAL BLACK 220V AC
PHASE
RED
Note: Use 1.5 Sq.mm. flexible wires for Phase, Neutral & Load connections
Mounting Metal box for the Device - 4 Module (75mmX140mmX60mm)
19. TOUCHART Remote Switch – 3+1 Zone
TA 113
Installation Manual
Specifications:
Supply voltage : 90 - 250V/AC
Supply frequency : 50-60 Hz
Number of switching zones : 3
Load per switching zone : 1000W resistive or 300W inductive Lamps or
4 fittings of fluorescent Lamps
Number of regulating/dimming zone : 1
Load per regulating/dimming zone : 200W of GLS or 100W of Halogen lamps or 1 fan.
Remote operating angle : 140°
Remote operating distance straight : 25 feet
Power consumption of wall unit : < 10 mw
Operating Temperature : -10°C to 55°C
Wiring Diagram (Rear View)
TOYAMA
RED PHASE IN NOTE:
Always Use
BLUE L1 TA 113 60mm Depth
L2 Metal Boxes.
BLUE
BLUE L3
FAN/D4 NEUTRAL BLACK
BLUE 220V AC
PHASE RED
Note: Use 1.5 Sq.mm. flexible wires for Phase, Neutral & Load connections
Mounting Metal box for the Device - 4 Module (75mmX140mmX60mm)
20. TOUCHART Remote Dimmer (Filament)
TA 340
Installation Manual
Specifications:
Supply voltage : 90 - 250V/AC
Supply frequency : 50-60 Hz
Number of filament dimming zone : 4
Load per regulating/dimming zone : 200W of GLS or 100W of Halogen lamps or 1 fan.
Remote operating angle : 140°
Remote operating distance straight : 25 feet
Power consumption of wall unit : < 10 mw
Operating Temperature : -10°C to 55°C
Wiring Diagram (Rear View)
TOYAMA
RED PHASE IN NOTE:
BLUE D1 TA 340 Always Use
60mm Depth
D2 Metal Boxes.
BLUE
BLUE D3
BLUE D4
NEUTRAL BLACK 220V AC
PHASE
RED
Note: Use 1.5 Sq.mm. flexible wires for Phase, Neutral & Load connections
Mounting Metal box for the Device - 4 Module (75mmX140mmX60mm)
21. TOUCHART Remote Dimmer (Florescent)
TA 340FD
Installation Manual
Specifications:
Supply voltage : 90 - 250V/AC
Supply frequency : 50-60 Hz
Number of florescent dimming zone : 4
Load per regulating/dimming zone : 3 fittings of fluorescent Lamps
Remote operating angle : 140°
Remote operating distance straight : 25 feet
Power consumption of wall unit : < 10 mw
Operating Temperature : -10°C to 55°C
Wiring Diagram (Rear View)
TOYAMA
RED
PHASE IN NOTE:
Always Use
BLUE
D1 TA 340FD 60mm Depth
D2 Metal Boxes.
BLUE
D3
BLUE
D4
BLUE
NEUTRAL BLACK
PHASE
RED
Note: Use 1.5 Sq.mm. flexible wires for Phase, Neutral & Load connections
Mounting Metal box for the Device - 4 Module (75mmX140mmX60mm)
22. TOUCHART CURTAIN SWITCH -2 Zone
TA 504
Installation Manual
Specifications:
Supply voltage : 90 - 250V/AC
Supply frequency : 50-60 Hz
Number of Curtain zones : 2 (Open, Close & Stop)
Remote operating angle : 140°
Remote operating distance straight : 25 feet
Power consumption of wall unit : < 10 mw
Operating Temperature : -10°C to 55°C
Wiring Diagram (Rear View)
TOYAMA
RED PHASE IN NOTE:
BLUE
C1-OPEN TA 504 Always Use
60mm Depth
BLUE C1-CLOSE Metal Boxes.
BLUE C2-OPEN
BLUE C2-CLOSE
NEUTRAL BLACK 220V AC
PHASE
RED
Note: Use 1.5 Sq.mm. flexible wires for Phase, Neutral & Load connections
Mounting Metal box for the Device - 4 Module (75mmX140mmX60mm)
23. TOUCHART Scene Maker
TA 706
Installation Manual
Specifications:
Supply voltage : 90 - 250V/AC
Supply frequency : 50-60 Hz
Number of Scenes : 6 +1 Scenes
Communication protocol : RS 485
Number of TA Devices with RS485
to be connected : 1 to 15 nos
Remote operating angle : 140°
Remote operating distance straight : 25 feet
Power consumption of wall unit : < 10 mw
Operating Temperature : -10°C to 55°C
Wiring Diagram (Rear View)
GREEN
BLACK
TOYAMA
NOTE:
_
+ 485 Always Use
RS
TA 706 60mm Depth
Metal Boxes.
BLACK
NEUTRAL
220V AC
PHASE
RED
Note: Use 1.5 Sq.mm. flexible wires for Phase, Neutral & Load connections
Mounting Metal box for the Device - 4 Module (75mmX140mmX60mm)
24. TOUCHART Remote Switch -7zone
TA 107
Technical Manual
Specifications:
Supply voltage : 90 - 250V/AC
Supply frequency : 50-60 Hz
Number of switching zones : 7
Load per switching zone : 1000W resistive or 300W inductive Lamps or
4 fittings of fluorescent Lamps
Remote operating angle : 140°
Remote operating distance : 25 feet
Power consumption of wall unit : < 10 mw
Operating Temperature : -10°C to +55°C
Wiring Diagram (Rear View)
TOYAMA
PHASE RED
TA 107 NEUTRAL BLACK
BLUE L1
PHASE IN
BLUE L2
L3
BLUE
L6 L7 L4 L5
PHASE IN
RED
BLUE
BLUE
BLUE
BLUE
RED
NOTE:
Always Use
60mm Depth
Metal Boxes.
Note: Use 1.5 Sq.mm. flexible wires for Phase, Neutral & Load connections
Mounting Metal box for the Device - 8 Module (75mmX210mmX60mm)
25. TOUCHART Remote Switch -5+2 zone
TA 125
Technical Manual
Specifications:
Supply voltage : 90 - 250V/AC
Supply frequency : 50-60 Hz
Number of switching zones : 5
Load per switching zone : 1000W resistive or 300W inductive Lamps or
4 fittings of fluorescent Lamps
Number of regulating/dimming zones : 2
Load per regulating/dimming zone : 200W of GLS or 100W of Halogen lamps or 1 fan.
Remote operating angle : 140°
Remote operating distance : 25 feet
Power consumption of wall unit : < 10 mw
Operating Temperature : -10°C to +55°C
Wiring Diagram (Rear View)
TOYAMA
TA 125
BLUE L2 L1 BLUE
L6
BLUE
L3 BLUE
D5/FAN2
D4/FAN1
PHASE
NEUTRAL PHASE
BLACK RED
PHASE L7
RED BLUE
BLUE
BLUE
RED
NOTE:
Always Use
60mm Depth
Metal Boxes.
Note: Use 1.5 Sq.mm. flexible wires for Phase, Neutral & Load connections
Mounting Metal box for the Device - 8 Module (75mmX210mmX60mm)
26. TOUCHART REMOTE COMBINATION SWITCH
TA 523
Technical Manual
Specifications:
Supply voltage : 90 - 250V/AC
Supply frequency : 50-60 Hz
Number of switching zones : 3
Load per switching zone : 1000W resistive or 300W inductive Lamps or
4 fittings of fluorescent Lamps
Number of regulating/dimming zones : 2
Load per regulating/dimming zone : 200W of GLS or 100W of Halogen lamps or 1 fan.
Curtain zone : 1 (Open, Close & Stop)
Remote operating angle : 140°
Remote operating distance : 25 feet
Power consumption of wall unit : < 10 mw
Operating Temperature : -10°C to +55°C
Wiring Diagram (Rear View)
TOYAMA
TA 523
L2 L1
BLUE BLUE
BLUE C-0pen
PHASE IN
L3
BLUE
D4/FAN1
D5/FAN2
NEUTRAL PHASE IN
BLACK RED
PHASE C-Close
RED BLUE
BLUE
BLUE
RED
NOTE:
Always Use
60mm Depth
Metal Boxes.
Note: Use 1.5 Sq.mm. flexible wires for Phase, Neutral & Load connections
Mounting Metal box for the Device - 8 Module (75mmX210mmX60mm)