Journal of Pharmaceutical and Biomedical Analysis
22 (2000) 613–624
Short communication
Simultaneous determination of levodopa, carbidopa and
their metabolites in human plasma and urine samples using
LC-EC
Kamal A. Sagar, Malcolm R. Smyth *
School of Chemical Sciences, Biomedical and En6ironmental Sensor Technology Centre, Dublin City Uni6ersity, Dublin 9, Ireland
Received 10 May 1999; received in revised form 16 September 1999; accepted 19 September 1999
Abstract
In this study levodopa (L-DOPA), carbidopa (C-DOPA) and their metabolites were resolved from other
endogenous components present in human plasma and urine and determined quantitatively. The developed technique
involved the use of a second pump, a switching valve, and a pre-column in the LC system in order to perform on-line
sample clean-up and enrichment. This procedure is dependent on an effective removal of the many interfering matrix
components that vitiate HPLC analysis. Several unknown endogenous electroactive compounds, present in plasma,
were eliminated by the purification step, or suppressed by the pre-treatment or detection conditions. The analyses
were separated on an Octyl-bonded reversed-phase column followed by amperometric detection using a carbon fibre
microelectrode flow cell operated at +0.8 V versus silver/silver phosphate reference electrode. The cell was
compatible with the mobile and the stationary phase used in the flow system without any complex surface reaction.
The peak currents obtained for the different analytes were directly proportional to the analyse over the concentration
range 0.02–4.0 mg ml−1
. Using this method, the minimum detectable concentration was estimated to be 5 and 8 ng
ml−1
for L-DOPA and C-DOPA, respectively. Recovery studies performed on human plasma samples ranged from
93.83 to 89.76%, with a relative standard deviation of B6%. The intra- and inter-assay coefficients of variation were
B7%. The accuracy of the assay, which was defined as the percentage difference between the mean concentration
found and the theoretical (true) concentration, was 12% or better. The electrochemical pre-treatment regime described
in this work permitted a longer application of the same microelectrode. The method showed a good agreement with
other available methods described in the introduction and offers the advantages of being simple, less time and labour
consuming, does not require additional solvents for extraction, inexpensive and suitable for routine analysis and
kinetic purposes. © 2000 Elsevier Science B.V. All rights reserved.
Keywords: Levodopa; Carbidopa; 3-orthomethyl dopa; 3-ortho carbidopa; Human plasma profiles; Urine concentration; Reversed-
phase liquid chromatography; Amperometric detection; Carbon fibre flow cell
www.elsevier.com/locate/jpba
* Corresponding author. Tel.: +353-1-7045308; fax: +353-1-7045032.
E-mail address: smythm@ccmail.dcu.ie (M.R. Smyth)
0731-7085/00/$ - see front matter © 2000 Elsevier Science B.V. All rights reserved.
PII: S0731-7085(00)00237-5
K.A. Sagar, M.R. Smyth / J. Pharm. Biomed. Anal. 22 (2000) 613–624614
1. Introduction
Parkinsonism, first described by Parkinson in
1817, is characterised by rigidity, tremor and
bradykinesia. The observation that the transmitter
dopamine in basal ganglia is markedly decreased
in Parkinson’s disease (PD) [1] lead to the devel-
opment of its metabolic precursor levodopa (L-
DOPA) (3,4-di-hydroxy phenyl alanine) (Fig. 1),
initially alone [2] and later combined with periph-
eral decarboxylase inhibitors (e.g. benserazide and
carbidopa (C-DOPA)) as a substitution therapy
used in combination to treat PD [3–6]. By reduc-
ing daily L-DOPA dosage requirements in this
manner, the addition of C-DOPA also reduces the
side effects associated with L-DOPA administra-
tion. C-DOPA (S,h-hydrazino-3,4-dihydroxy-h-
methyl-benzene propionic acid; Fig. 1) is the
hydrazino derivative of methyldopa, which in-
hibits the decarboxylation of L-DOPA in periph-
eral tissues and, thus, allows a greater amount of
the L-DOPA dose to be transported into the
central nervous system and increases its accessibil-
ity to nigrostriatal sites of action in the brain. A
change in the concentration of one or both drugs
in the body may influence the bioavailability and
biopharmaceutic properties of the pharmaceutical
preparation and subsequently their magnitude of
action [7]. The treatment using these drugs
provide symptomatic relief to most patients at the
initial stages of disease, although unpredictable
symptom fluctuations in the effect of these drugs
are seen in advanced stages of the disease. The
finding that fluctuations in motor performances of
patients with PD receiving L-DOPA in combina-
tion with the aromatic amino acid decarboxylase
inhibitors carbidopa or benserazide, are a major
problem in the treatment of this disorder and a
constant plasma concentration of these drugs sta-
bilises the symptoms [7–9] have focused interest
on developing different methods to monitor
simultaneously the concentration of these drugs in
biological fluids to assist in the management of
this disease. One of the most significant advances
in quantitation techniques has been the develop-
ment of electrochemical detectors combined with
HPLC (LC-EC), which offers the capability of
selective and sensitive determination of electroac-
tive oxidizable or reducible drug products, with
little interference from biological matrix interfer-
ences [10] and with low limits of detection down
to picogram quantities [11]. Few detection meth-
ods used can compare for simplicity and perfor-
mance [11]. Of the numerous methods [12–29]
reported for the determination of these drugs in
biological fluids, few permit a simultaneous quan-
titative determination of both drugs and their
metabolises in biological fluids. Some of these
procedures are difficult to set up, expensive and
require great care in maintaining satisfactory con-
trols [18]. However, there is no general agreement
as to their extraction and clean-up procedures
from biological fluids [19]. Radioenzymatic assays
involve conversion of DOPA to dopamine, and
the intrinsic dopamine must be subtracted from
the final volume [14,15]. Some of these assays
proposed for clinical use were developed using
biological fluids obtained from animals. Experi-
mental animals are usually kept under much more
controlled conditions than people live in. Conse-
quently chromatograms of extracts of biological
fluids from animals tend to be more reproducible
and cleaner than those from people and may be
misleading. HPLC methods used for the simulta-
neous determination of these compounds in rat
brain were sensitive, but they were not selective
enough to be applied to complex biological sam-
ples, such as urine and plasma, even when the
samples were purified by extraction with an or-
ganic solvent [20,21], acid-washed alumina [22,24]
or boric acid gel [23,28,29]. Other methods have
relied upon alumina extraction for separation of
cathecol compounds [24], with a separate ion-ex-
change isolation step for OMD and other O-
methylated cathecol metabolites or, because of
similar retention times of OMD and C-DOPA,
have been unable to resolve the two in clinical
Fig. 1. Basic structural formulae of levodopa (a) and car-
bidopa (b).
K.A. Sagar, M.R. Smyth / J. Pharm. Biomed. Anal. 22 (2000) 613–624 615
samples [17,25]. The procedure using aluminium
oxide, however, has several disadvantages; it is a
complicated and time-consuming task, there is
difficulty in activation of aluminium oxide and
there is low recovery. Gas-chromatographic
methods have been described [26,27], but these
involve the inconvenience of multiple derivatiza-
tion. In view of the importance of determining
these drugs in human plasma as a tool in under-
standing the pharmacotherapy in PD, we
present in this paper a selective and sensitive
analytical procedure for the quantitation of L-
DOPA, C-DOPA, and their active metabolites
in human plasma using a carbon fibre micro-
electrode flow cell previously reported by our
laboratory [30], in combination with an auto-
mated column switching assembly which in-
cluded the use of two columns to extract and
resolve the major drugs components and their
metabolites in human plasma and urine. The use
of two columns allowed the co-elution of the
analytes from the first column, but are separated
from the excess reagent and other side products
in the sample. The peaks of interest are then
switched to the second column where they are
separated from each other. This particular type
of column switching is often referred to as
‘heart-cutting’ [31]. To our knowledge such pro-
cedures have not been reported previously for
the determination of these drugs and their
metabolites simultaneously in biological fluids.
The convenience of our method is facilitated by
its rapidity, ease of sample preparation by using
a fast single-extraction and enrichment step, and
the use of a low cost commercially available
carbon fibre. These advantages are of important
consideration in performing bioavailability stud-
ies or in clinical routine analysis involving a
large number of plasma samples.
2. Experimental
2.1. Chemicals and reagents
All reagents and chemicals were ACS Reagent
Grade and were used without purification.
Sodium dihydrogen orthophosphate was pur-
chased from Fluka (Buchs, Switzerland). Or-
thophosphoric acid was supplied by BDH
(BDH, Poole, Dorset, UK). All other chemicals
were obtained from Sigma (Pool, Dorset, UK).
Water was distilled and then further purified by
passing through a Milli-Q water purification sys-
tem (Millipore, Milford, MA, USA). Plasma
samples were obtained from normal human vol-
unteers. Heparinized plastic tubes used for
whole blood collection ‘LiHeparin Menovette’,
were supplied by Sarstedt (Numbrecht, Ger-
many). Carbon fibres, 14 mm in diameter, were
obtained from AVCO (Lowell, MA, USA). The
surface of these fibres has no external coating.
Silver epoxy was purchased from RS compo-
nents (Corby, Northants, UK) and the glassy
carbon used in the comparison studies was ob-
tained from EG&G Princeton Applied Research
(Princeton, NJ, USA).
2.2. HPLC-mobile phase
The mobile phase used was a mixture of 16.5
g of sodium dihydrogen orthophosphate, 980 ml
of water, 1.0 ml of 0.10 M disodium ethylenedi-
amine tetra-acetic acid (EDTA), 20 ml of
methanol and 1.2 ml of 0.5 mM sodium hep-
tanesulphonate (HAS) with the pH adjusted to
3.4 with 1 M orthophospharic acid. The mobile
phase was filtered through a pore size 0.45 mm
cellulose membrane filter (HVLP, Millipore,
Bedford, MA, USA), degassed under reduced
pressure and used at ambient temperature. With
a flow-rate of 1 ml min−1
, the elution using this
mobile phase was carried out at this tempera-
ture. The EDTA was used to sequester any oxi-
disable metal ions.
2.3. HPLC-columns
An Octyl-bonded/reversed phase column (12.5
cm×4.0 mm I.D. 5-mm particle size, Lichrosorb
RP-8 Hibar) was used for the purpose of the
purification of deproteinized plasma and urine
samples as well as for preconcentration of the
different analytes. The second column, 25.0
cm×4.0 mm I.D. 5-mm reversed-phase column
(Ultrasphere), was used for the separation of the
K.A. Sagar, M.R. Smyth / J. Pharm. Biomed. Anal. 22 (2000) 613–624616
Fig. 2. Sketch of the flow pattern through the column switch-
ing system, used for retaining the analyses in the pre-concen-
tration column (a) and eluting the drugs from the
pre-concentration column (b).
2.4. Equipment
Plasma centrifugation was performed on a Mi-
crofuge 12 microcentrifuge from Beckman Instru-
ments (Fullerton, CA, USA). All analyses were
performed on HPLC waters system consisted of
two pumps (Waters Model 501). Sample introduc-
tion was via a Rheodyne (Cotate, CA, USA)
Model 7125 injection valve, fitted with a 25 ml
loop for direct injection. For the purpose of ex-
traction by column switching, the injection was
fitted with a l ml loop and a second pump (pump
A), and the concentration column was connected
to the analytical assembly via a Rheodyne Model
7000 six-port switching valve. Fig. 2 illustrates
schematically the configuration of the column-
switching system at the valve positions A and B.
At position A, the loading/washing eluent deliv-
ered by pump A eluted the gross plasma interfer-
ents to waste, whereas the drugs and their
metabolites were completely retained. When the
valve rotated to position B, the analytes were
swept onto the concentration column by the mo-
bile phase where it was separated and subse-
quently detected. Oxidative amperometric
measurements were performed using a Model 400
EC potentiostat (EG&G Princeton Applied Re-
search) connected to the flow cell by crocodile
clips. The resultant signals were recorded on a
Philips Model PM 8261 x-t recorder (Eindhoven,
The Netherlands) at a chart speed of 33 mm h−1
.
The peak currents (measured as peak heights on
the recorder) as a function of concentration were
then measured for quantitative analysis.
2.5. Fabrication of micro-electrode flow cell
The micro-electrodes used were fabricated from
carbon fibres, the diameter of which is 14 mm.
There are two prominent features of the electro-
chemistry attained at these electrodes: first, their
small size results in predominantly diffusion-con-
trolled currents that are time-independent within
a very short time of the initial application of
potential; secondly, surface conditions can con-
tribute significantly to the electrochemical reac-
tions at the electrode. The method of inserting the
carbon fibre into a polyethylene tube is shown in
compounds eluted from the concentration
column. A 2 mm pre-column filter (Rheodyne) was
also used. The column was normally operated at a
back-pressure of 93 bar. The analytical column
was primed by recycling the mobile phase
overnight at a flow-rate of 0.3 ml min−1
At the
end of a use period, the column was washed free
of mobile phase components with 400–500 ml of
water and then was returned by means of a
gradient to 70% methanol for storage. The
column in use retained good efficiency and resolu-
tion for over 6 months despite prolonged expo-
sure to aqueous solutions, and the matrix effects
of the biological samples used.
K.A. Sagar, M.R. Smyth / J. Pharm. Biomed. Anal. 22 (2000) 613–624 617
Fig. 3(a). The needle holes were sealed by gently
heating with an electric iron. The construction of
the counter electrode was described previously
[30]. The working, reference, and counter elec-
trode were mounted in a T-tube arrangement
(Fig. 3(b)), and the working electrode was con-
nected to the outlet of the HPLC column (down-
stream of the working electrode). Hence the
mobile phase eluent passed first through the
working electrode and then via the counter elec-
trode to waste. Placing the auxiliary electrode in
this position reduces the uncompensated resis-
tance to negligible value even with the low ionic
strength of the mobile phase in use. With such a
low uncompensated resistance the interfacial elec-
trode potential is not significantly influenced by
sample concentration, and a wide linear range was
obtained.
2.6. Optimisation of detection potential
In order to determine the optimum applied
potential for both drugs, hydrodynamic voltam-
mograms were obtained by repeated injections of
40 ng ml−1
L-DOPA and C-DOPA standard
solutions into the chromatography system and
recording the peak currents, at fixed applied po-
tentials versus Ag/Ag3PO4. The detector operating
oxidation voltage was increased from roughly 0.2
to 1.2 V in 0.2 V increments.
2.7. Standard solutions and linearity
Plasma standards were prepared from blank
human plasma spiked with L-DOPA, C-DOPA,
and their metabolites (3-OMD, and 3-OMC), in
the range 0.02–4 mg ml−l
, which is enough to
cover the range of expected patient values (usually
up to 3.5 mg ml−1
. The working dilutions were
divide into aliquots, which were frozen immedi-
ately at−70°C, protected from light for maxi-
mum stability, till used for analysis. Each
calibration point was run in triplicate over five
consecutive days, and the observed coefficient of
variation (C.V.) for each standard curve was cal-
culated from the least-squares regression equa-
tions. The overall performance of the system was
verified periodically by injection of standard
samples.
2.8. Extraction reco6ery
The extraction efficiency and recovery of the
assay was assessed at concentrations of 0.5, 1.0
and 1.5 mg ml−1
. Six replicates of each concentra-
tion containing the two compounds in human
plasma were injected into the column and ex-
tracted according to the method described. The
recovery of both drugs from plasma was assessed
by comparing the peak current of the extracted
plasma samples with the peak current of authentic
(unextracted, aqueous) standards, which were di-
rectly injected (i.e. without column switching)
onto the analytical column at the concentration
levels, and the assay recovery was calculated using
the following equation:
% recovery
=(mean peak height plasma extract)
/(mean peak height standard)×100
2.9. Specificity of the method
In order to examine the presence of any inter-
ferences from the active metabolites of both drugs
and other impurities that might exist in the phar-
Fig. 3. Structure of the carbon fibre micro-flow cell: (a)
Method of fixing a carbon fibre into polyethylene tube. (b)
Diagram of the carbon fibre micro-flow cell consisting of (1)
silver wire coated with Ag3PO4, (2) reference electrode body,
(3) internal reference solution, (4) T- tube, (5) ceramic rod, (6)
stainless-steel counter electrode and (7) fibre flow electrode.
K.A. Sagar, M.R. Smyth / J. Pharm. Biomed. Anal. 22 (2000) 613–624618
Fig. 4. Hydrodynamic voltammograms of levodopa ( ) and
carbidopa (
) obtained by injections of a standard solution
prepared in the mobile phase into the chromatograph. Mobile
phase: see text, pH 3.4; working electrode: 14 mm carbon fibre
at different potentials versus Ag/Ag3PO4.
of two electrons and two protons, yielding ortho-
quinone. Fig. 4 shows the hydrodynamic voltam-
mograms of L-DOPA and C-DOPA prepared in
the mobile phase. The voltammograms represent
a rapidly achieved mass transport steady state.
Plot of applied potential (E) against peak current
exhibited one wave for each drug and showed a
distinct sigmoidal dependence upon applied po-
tential. The magnitude of the current is directly
proportional to the bulk concentration at every
point along the voltammetric curve. The single
anodic peak obtained in the range studied verifies
that both compounds underwent a single oxida-
tion process within this range and was also depen-
dent on the change in pH, although it is often
desirable to operate an electrochemical detector
on the limiting current plateau; in this case it was
advantageous to operate on the rising part of the
curve. The lower the potential chosen, the lower
the background current produced and better sen-
sitivity is obtained. Higher potentials resulted in
greater background current and the electrochemi-
cal detector was unlikely to be useful for trace
analysis as the background oxidation became ex-
orbitant. A working potential of +0.8 V afforded
a significant reduction in background current,
which resulted in better signal-to-noise ratios and
this potential was selected for the reminder of the
LC-EC studies.
3.2. Separation of the analytes in human plasma
Reversed-phase chromatography appears to be
most useful in the analysis of mixtures of such
substances which posses both acidic and basic
organic functional groups. Deproteinized plasma
samples were injected directly into the HPLC
system; every four samples were followed by a
standard. The first step in the set-up of the switch-
ing/separation system involved the selection of a
suitable pre- (or concentration) column, which
would retain the analytes while other endogenous
components are eluted to waste. Among the dif-
ferent columns used for this purpose, an Octyl-
bonded/reversed phase column (12.5 cm×4.0 mm
I.D. 5 mm-particle size, Lichrosorb RP-8 Hibar)
showed the most favourable retention characteris-
tics for both drugs and their metabolites. The next
maceutical preparation used in the method devel-
oped. The sensitivities, retention times and extrac-
tion recoveries for these two drugs were
determined by the above procedures in the pres-
ence of these substances at a concentration of 1
mg ml−1
.
2.10. Urine analysis
Samples with 2.0 ml of chlorhexidine gluconate
added as a preservative were acidified immediately
to a pH of 2 with a 6 M HCl to increase the
stability [11]. The samples were then deproteinised
by the addition of 0.01 M HCl and l M perchloric
acid, the mixture was vortexed and centrifuged at
630 g at 5°C for 20 min [12]. Before analysis, the
samples were filtered through 0.22 mm cellulose
filters (Millipore, Sergrate MI, Italy).
3. Results and discussion
3.1. Optimisation of oxidation potential
Each of the analyses contains a phenol or cate-
chol functionality, which can be easily detected by
direct anodic oxidation at relatively low potential
[11,32]. The detector operated in the amperomet-
ric mode with a fixed potential sufficiently positive
to force the ortho-hydroxy groups to undergo loss
K.A. Sagar, M.R. Smyth / J. Pharm. Biomed. Anal. 22 (2000) 613–624 619
stage was to find two compatible eluents of differ-
ent elutropic strengths; one should have a poor/
elution capability to concentrate the analyses on
the pre-column, and a second strongly eluting
solvent to elute the analytes off the pre-column
and onto the analytical column. The washing
eluent should also be miscible with the mobile
phase, as even slight incompatibility could result
in a slug of solvent travelling down the analytical
column, partially carrying sample components
which may cause band broadening. The use of a
0.05 M solution of perchloric acid allowed the
purification of plasma samples by washing out
neutral and acidic compounds while the analyses
(containing amino groups) were retained by the
pre-column. A wash time (defined as the length of
time between injection and switching of the valve)
of 1.5 min was found to be satisfactory to provide
a good clean-up of the plasma components with-
out causing the analytes to elute. Six replicate
injections of plasma samples containing the differ-
ent analyses yielded a relative standard deviation
(RSD) 5% for each substance. The configura-
tion of the LC-EC system, the size of the packing
materials used in both columns and the choice of
the suitable columns and mobile/washing eluents
had reduced the back-pressure and pressure jumps
caused by switching of two HPLC columns, and
in return reduced the possibility of unacceptable
baseline disturbances or any peak broadening
usually caused by the use of large particles. Mem-
ory effects, a usual problem occurring when using
column switching chromatography, was never en-
countered using such a configuration.
Fig. 5 shows the chromatogram of a spiked
plasma sample containing 0.3 mg ml−1
L-DOPA/
3-OMD and 0.35 pg ml−1
C-DOPA/3-OMC. The
figure clearly indicates that under the experimen-
tal conditions, both drugs were well resolved from
the endogenous plasma peaks flanking it and their
main metabolites. The mobile phase was opti-
mised by careful examination of all major vari-
ables, including pH and ionic strength, to
determine their influence on enhancing peak sepa-
ration without prolonging the analysis time for
each sample. In such separations, an acidic pH
proves optimal and modest pH adjustments can
produce significant changes in the retention time
characteristics of these substances. The pH se-
lected for the mobile phase did not significantly
alter the peak characteristics, even after 6 months
of continuous use. There was no interference from
the heparin and sodium metabisulphite, which are
added to the blood as anticoagulant and antioxi-
dant, respectively. The retention sequence for the
different analyses can be explained due to the
basis of the difference in the polarity. The primary
amine levodopa elutes well before the less polar
hydrazine-containing carbidopa. Methyl dopa and
methylcarbidopa, due to the extra methyl group,
are retained more, relative to L-DOPA and C-
DOPA, respectively. The importance of separat-
ing and detecting these metabolites lies in the side
Fig. 5. A chromatogram obtained by direct injection of de-
proteinized plasma sample containing L-DOPA, 3-OMD, C-
DOPA and 3-OMC. Peaks: 1=L-DOPA; 2=3-OMD;
3=C-DOPA; 4=3-OMC.
K.A. Sagar, M.R. Smyth / J. Pharm. Biomed. Anal. 22 (2000) 613–624620
Fig. 6. Chromatograms of 0.3 mg ml−1
levodopa obtained by analysing the drug (A) before and (B) after electrochemical
pre-treatment of the working electrode.
effects caused by their presence during long term
therapies. Side-effects (dyskinesia, on-off phenom-
ena and psychoses) is attributed to the high levels
of 3-OMD in plasma and/or the plasma 3-OMD/
L-DOPA ratio [33,34]. Furthermore, hypokinesia
( a situation associated with low plasma levels of
L-DOPA) can occur due to a competition for
transport across the blood–brain barrier between
L-DOPA and 3-OMD [35], and the determination
of O-methylated products might be of clinical
significance in psychiatric disorders [36]. Other
metabolic pathways are unimportant [37].
3.3. Pre-treatment of the micro-electrode
Due to its inherent surface characteristics, car-
bon often exhibits poor electron-transfer kinetics.
This seems to be especially true for analysis of
anionic species. Since the voltammetric response
at carbon surfaces often degrades at an enhanced
rate when placed in biological media, presumably
due to adsorption of large molecules to the elec-
trode surface, a process is required to renew the
carbon surface before obtaining electrochemical
information. The surface of the electrode used
often changed after several runs (Fig. 6(a)). One
reason for such changes is due to either the ad-
sorption of species from solution or chemical
changes which could have occurred on the elec-
trode surface itself possibly because of the differ-
ent reactions between the analyte and the
electrode surface or due to a resultant by-product.
These changes produced a high baseline noise
resulted in variations in sensitivity, reproducibility
and selectivity. A variety of methods have been
used in the past by different workers, among these
was laser treatment of the working electrode [38]
and electrochemical pre-treatment [39].
The latter was preferred due to the configura-
tion of the system and the availability of such
treatment within the system used. Anodisation of
the microelectrode at +1.0 V for 60 s, then
cathodisation at −1.0 V for another minute,
followed by equilibration at the working potential
for 5 min was enough to remove any surface
contaminants or inhibitory layers which hindered
transport of electrons and oxidation of the species
at the electrode surface. The activation of the
K.A. Sagar, M.R. Smyth / J. Pharm. Biomed. Anal. 22 (2000) 613–624 621
electrode surface as a result of the pre-treatment
process can produce quinoidal functionalities and
improve the current response [40]. Fig. 6b illus-
trates clearly the influence of the pre-treatment
regime in the base-line noise and the signal-to-
noise ratio level.
3.4. Method e6aluation
3.4.1. Linearity and detection limits
Linear calibration graphs of peak heights of the
standards, versus the concentration of the stan-
dards were constructed by analysing spiked blank
plasma over five days in the concentration range
0.02–4.0 mg ml−1
. This concentration range is
within the therapeutic levels for these drugs
[7,41–43]. The resulting current was directly pro-
portional to the concentration of the oxidisable
species. The plotted points represented the means
of at least five replicate injections per standard.
The curves showed a good linearity between the
detector response and the analyte concentration.
For each of the five regression lines the correla-
tion coefficients (r2
) were all greater than 0.993.
The coefficient of variation of the slopes (n=5) of
the regression lines calculated from the least
squares regression equations, ranged from 3.0–
8.74%, with intercepts all close to zero.
The sensitivity of the method is often expressed
as the limit of detection (LOD). The LOD for the
analysis is defined as the standard deviation of the
base line noise. The measurement of the base line
noise is not ambiguous and a more useful way to
describe the sensitivity when blood or urine sam-
ples are analysed could be to calculate the instru-
mental limit of detection (ILOD) and the limit of
quantitation (LOQ). The ILOD is the amount of
an analyse giving a peak height three times the
standard deviation of the base line noise without
any matrix interference, whereas the LOQ is the
concentration of an analyse in the matrix that
could be determined with a precision (a signal-to-
noise ratio of 3) under the given analytical proce-
dure. In our case the ILOD for L-DOPA and
C-DOPA was found to be 5 and 8 ng ml−1
,
respectively. The LOQ was ca. 8 ng ml−1
for
L-DOPA and 10 ng ml−1
for C-DOPA. This limit
of quantitation is adequate for clinical analysis
and pharmacotherapeutic studies and comparable
to those values obtained by previous workers
[3,6,44–46]. The use of relatively low potential,
incorporation of reference and auxiliary elec-
trodes in the same cell and recycling of the mobile
phase, all resulted in reduction of the back-
ground noise and improved LOD and LOQ
values.
3.5. Precision and extraction reco6ery
The column switching technique usually gives
better precision than the traditional direct injec-
tion technique for micro-samples [47]. The preci-
sion of the method based on peak-height
measurements was evaluated by replicate injection
exhibited a coefficient of variation of B6.0%.
Peak-height measurements were found to yield the
same reproducible results as peak-area determina-
tions, and there was no need to include an inter-
nal standard in the analysis due to the good
recovery and reproducibility obtained. The mean
absolute recovery achieved with the described ex-
traction procedure was always greater than 91.0%
for L-DOPA and 89% for C-DOPA. Table 1
illustrates the precision and extraction recovery
for both drugs using the technique described.
3.6. Selecti6ity of the method
The possible potential various foreign com-
pounds were studied; these compounds were se-
lected according to (a) compounds which can be
present as impurities in combination with the
drugs in different pharmaceutical formulations
and affect the analytical process and (b) other
drugs that might be administered with these
drugs. United States Pharmacopoeia (USP) [48]
specifies methyl dopa, 3-methoxy tyrosine, and
3-O-methyl carbidopa as impurities in the analy-
sis of L-DOPA–C-DOPA combination formula-
tions. Interference from some of these substances
in the determination of the drugs was tested in
two different studies using the proposed tech-
nique. The separation peak height, retention times
and the recovery of the analyses were not affected
by the presence of these substances. Errors B2%
were calculated by comparing the results with the
K.A. Sagar, M.R. Smyth / J. Pharm. Biomed. Anal. 22 (2000) 613–624622
Table 1
Precision and extraction recovery
Mean concentration found (mgConcentration added (mgCompound Recovery (%) Coefficienta
of variation Accuracyb
(%)ml−l
)ml−l
)
0.459 91.83L-DOPA 4.700.5 4.10
1.0 0.925 92.50 3.92 7.50
1.407 93.86 3.101.5* 9.30
0.449 89.80C-DOPA 5.200.5 5.10
0.913 91.311.0 4.63 8.70
1.5* 1.387 92.47 3.75 11.30
a
Mean of six samples from single plasma pool assayed in triplicate.
b
The percentage difference between the mean concentration found and the theoretical concentration.
* Highest concentrations observed in clinical samples.
corresponding results obtained with a solution
containing only both drugs. Other drugs such as
tricyclic antidepressants (Desipramine) that might
be co-administered with both drugs was not ob-
served under the experimental conditions. The
selectivity and the resolution of the column was
enhanced by the use of an ion pairing species
(HSA), and by the admixture of an organic
modifier such as methanol in the mobile phase.
3.7. Inter- and intra-assay 6ariability
Within-day variabilities were established for
five different days concentrations (0.25, 0.5 and
l.5 mg ml−1
) for dopa and carbidopa by adding
the drugs to blank plasma over five consecutive
days. Peak current values were interpolated on the
individual regression lines to yield three new val-
ues of amount found at each concentration level
for every day. Between-day variability was then
calculated by obtaining the mean C.V (%). Re-
sults from this experiment are presented in Table
2, and they show that the overall assay variations
at 0.25, 0.5 and l.5 mg nl−1
were B7% for both
drugs.
3.8. Stability studies
The stability of the electrode is of importance in
order to define the period of time over which the
electrode can be used without a significant de-
crease in the sensitivity. After 1 week it was
observed that a significant decrease in the sensitiv-
ity has occurred even with the use of the electro-
chemical pre-treatment procedure. The electrode
response was at 45% of its initial value, with
relative standard deviations greater than 13%.
The amperometric detector was left on as long as
Table 2
Inter- and intra-assay variability
Compound Intra-assayInter-assay
C.V. (%)Concentrationa
(mg ml−1
) Concentration (mg ml−1
) C.V. (%)
0.25 5.1 0.25 6.73Levodopa
0.50 4.70 0.50 5.91
3.561.50 4.541.50
0.255.34 6.860.25Carbidopa
0.50 4.55 0.50 5.34
1.50 3.21 1.50 4.23
a
Individual values are the mean of three measurements.
K.A. Sagar, M.R. Smyth / J. Pharm. Biomed. Anal. 22 (2000) 613–624 623
Table 3
Absolute recovery of L-DOPA and 3-OMD from urine sam-
ples
ConcentrationSubstance Mean concentration
recovereda
(mg ml−1
)
2.0L-DOPA 1.87
3.0C-DOPA 2.81
a
n=5.
from other endogenous components present in
urine or plasma, it is not so subject to sample loss
during transfer stages as off-line methods, and
can be useful in routine biomedical and clinical
investigations of these drugs and their metabo-
lites. A work involving the use of this method in
studying the different pharmacokinetic parame-
ters and estimation of drug bioavailability in pa-
tients receiving different formulations containing
a combination of these drugs and identification of
impurities in these formulations will be conducted
in our laboratory in the near future.
References
[1] W.C. Bowman, M.J. Rand, Text book of Pharmacology,
2nd edition, Blackwell Scientific Publications, Cambridge,
1980, pp. 18–19.
[2] M. Da Prada, H. Keller, L. Pieri, R. Kettler, W. Haefely,
Experientia 40 (1984) 1165–1304.
[3] D. Titus, T. August, K. Yeh, R. Eisenhandler, W. Bayne,
D. Musson, J. Chromatogr. 534 (1990) 87–100.
[4] D. Deleu, S. Sarre, G. Ebinger, Y. Michotte, J. Pharm.
Biomed. Anal. 11 (1993) 577–585.
[5] The Merck Index, 12th Edition, Merck and Company
Incorporated, NJ, US, 1996, pp. 292–293.
[6] I. Rondelli, D. Acerbi, F. Mariotti, P. Ventura, J. Chro-
matogr. B 653 (1994) 17–23.
[7] K. Yeh, T. August, D. Bush, K. Lasseter, D. Musson, S.
Schwartz, M. Smith, D. Titus, Neurology 39 (1989) 25–
38.
[8] M. Marion, F. Stocchi, N. Quinn, Clin. Neuropharmacol.
9 (1986) 165–181.
[9] J. Sage, L. Schuh, R. Heikkila, Clin. Neuropharmacol. 11
(1988) 36–44.
[10] P.T. Kissinger, R.M. Riggin, R.L. Alcorn, L.D. Rau,
Biochem. Med. 13 (1975) 299–306.
[11] P.T. Kissinger, Anal. Chem. 489 (1977) 447A–456A.
[12] T. Ishimitsu, S. Hirose, J. Chromatogr. 337 (1985) 239–
248.
[13] T. Ishimitsu, S. Hirose, Anal. Biochem. 150 (1985) 300–
308.
[14] G.A. Johnson, J.M. Green, R. Kupiecki, Clin. Chem. 24
(1978) 1927–1930.
[15] G. Zurcher, M. Da Prada, J. Neurochem. 33 (1979)
631–639.
[16] M.J. Brown, C.T. Dollery, Br. J. Clin. Pharmacol. 11
(1981) 79–83.
[17] M.P. Beers, M. Stern, H. Hurtz, A. Scarpa, J. Chro-
matogr. 336 (1984) 380–384.
[18] L. Rentzlog, Acta. Physiol. Scand. 377 (1972) 1–3.
[19] E. Nissinen, J. Taskinen, J. Chromatogr. 231 (1982) 459–
462.
the mobile phase flowed through the column and
the flow cell and the nature of the cell construc-
tion made it very stable in the mobile phase with
no leakage during its operating lifetime. The con-
tinuous washing process extended the life of the
cell and minimised the start-up time. The working
electrode was replaced every 7 days, but as such
an electrode can be easily and cost effectively
replaced, this problem of decreasing in sensitivity
is not of major consequence.
Stability of urine samples kept in an ice bath
was tested by making 5 consecutive injections of
same urine sample over a period of approximately
3 h. There were no significant changes in the peak
current between the first and the last samples. In
addition, urine samples were stable for over a
week when stored at −4°C. The recovery of the
drugs from spiked urine samples was satisfactory
(Table 3), and the concentration of the ‘spiked
samples’ did not appear to influence the recovery
of the residues in urine specimens.
4. Conclusions
The results demonstrate that L-DOPA, C-
DOPA and their metabolites can be effectively
resolved and quantitated in biological samples
with a single on-line extraction and enrichment
step followed by amperometric detection by em-
ploying a potential of +0.8 V at the working
electrode. The micro-flow cell described here is
simple to prepare and easy to manage. The cell
has the advantage of small iR drop, virtually
insignificant capacitive charging currents and a
rapid mass transport to and from the working
electrode. The method eliminates interferences
K.A. Sagar, M.R. Smyth / J. Pharm. Biomed. Anal. 22 (2000) 613–624624
[20] T.G. Rosano, H.H. Brown, J.M. Meola, Clin. Chem. 7
(1981) 228–231.
[21] A. Yoshioka, T. Sakai, Z. Tamura, J. Chromatogr. 227
(1982) 162–167.
[22] A.H. Anton, D.F. Sayre, J. Pharmacol. Exp. Ther. 138
(1962) 360–375.
[23] S. Higa, T. Suzuki, A. Hayashi, I. Tsuge, Y. Yamamura,
Anal. Biochem. 77 (1977) 18–24.
[24] J. O’Hanlon, H. Campuzano, S. Horvath, Anal. Biochem.
34 (1970) 567–581.
[25] A. Baruzzi, M. Contin, F. Albani, R. Riva, J. Chro-
matogr. 375 (1986) 165–169.
[26] Y. Mizuno, Clin. Chim. Acta 74 (1977) 9–11.
[27] C. Hansson, G. Agrup, H. Rorsman, A.M. Rosengren, J.
Chromatogr. 162 (1979) 7–22.
[28] H. Schott, E. Rudloff, P. Schmidt, R. Roychoudhury, H.
Kossel, Biochemistry 12 (1973) 932–938.
[29] H. Weith, J. Wiebers, P. Gilham, Biochemistry 9 (1970)
4396–4401.
[30] K.A. Sagar, M.R. Smyth, J. Wilson, K. McLaughlin, J.
Chromatogr. 659 (1994) 329–336.
[31] M. Mifune, D. Krehbiel, J. Stobaugh, C. Riley, J. Chro-
matogr. 496 (1989) 5570.
[32] P. Kabra, L. Manton, Clinical Applications of Liquid
Chromatography, Humana Press, New York, 1981, p.
253.
[33] E. Rivera-Calimlim, D. Tandon, F. Anderson, R. Joynt,
Arch. Neurol. 34 (1977) 228–232.
[34] M.D. Muenter, N.S. Sharpless, G.M. Tyce, Mayo Clin.
Proc. 47 (1972) 389–395.
[35] A. Reches, S. Fahm, Ann. Neurol. 12 (1982) 267–271.
[36] G. Marzullo, (1981) in Function and Regulation of Mon-
amine Enzymes: Basic Clinical Aspects, Proceedings 2nd
Conference, In: Usdin, E. Weinr, N., and Youdin, M.
(eds), pp.665–673, MacMillan, London.
[37] N. Sharpless, M. Muenter, G. Tyce, Clin. Chim. Acta 37
(1972) 359–369.
[38] T.G. Sterlin, A.G. Ewing, Anal. Chem. 63 (1991) 194–
198.
[39] J. Wang, P. Tuzhi, V.J. Villa, J. Electroanal. Chem. 234
(1987) 119–131.
[40] T.E. Edmonds, J. Guoliang, Anal. Chim. Acta 151 (1983)
99–108.
[41] P. Benetello, M. Furlanut, G. Zara, M. Baraldo, E.
Hassan, Eur. Neurol. 33 (1993) 69–73.
[42] A. Grahnen, S. Eckernas, C. Collin, A. Ling-Andersson,
G. Tiger, M. Nilsson, Eur. Neurol. 32 (1993) 343–348.
[43] E. Breberg, H. Lennernas, L. Paalzow, Pharm. Res. 11
(1994) 549–555.
[44] M. Gerlach, N. Klaunzer, H. Przuntek, J. Chromatogr.
380 (1986) 379–385.
[45] M. Da Prada, R. Kettler, G. Zurcher, R. Schaffer, W.
Heafely, Eur. Neurol. 27 (1) (1987) 9–12.
[46] Y. Michotte, M. Moors, D. Deleu, P. Herregodts, G.
Ebinger, J. Pharm. Biomed. Anal. 5 (1987) 659–664.
[47] C. Goewie, E. Hogendoorn, Sci. Total Environ. 47 (1985)
349–360.
[48] The United States Pharmacopeia, 23rd Revision, Rand
McNally, Taunton, MA, 1995, p. 270.
.

Contenu connexe

Tendances

Determination of cefadroxil antibiotic by an analytical method
Determination of cefadroxil antibiotic by an analytical methodDetermination of cefadroxil antibiotic by an analytical method
Determination of cefadroxil antibiotic by an analytical method
Alexander Decker
 
Publications-Indian_drugs__2016[1]-Mohan
Publications-Indian_drugs__2016[1]-MohanPublications-Indian_drugs__2016[1]-Mohan
Publications-Indian_drugs__2016[1]-Mohan
Mohan Thippeswamy
 
NRFPRESENTATIONNEWSAIP1finallypresentation13july
NRFPRESENTATIONNEWSAIP1finallypresentation13julyNRFPRESENTATIONNEWSAIP1finallypresentation13july
NRFPRESENTATIONNEWSAIP1finallypresentation13july
Musa Lonwabo Kwetana
 
020203 ps0096
020203 ps0096020203 ps0096
020203 ps0096
Jing Zang
 
depolymerization-of-high-molecular-weight-into-a-predicted-low-molecular-weig...
depolymerization-of-high-molecular-weight-into-a-predicted-low-molecular-weig...depolymerization-of-high-molecular-weight-into-a-predicted-low-molecular-weig...
depolymerization-of-high-molecular-weight-into-a-predicted-low-molecular-weig...
trunghieuchinh
 

Tendances (20)

Determination of cefadroxil antibiotic by an analytical method
Determination of cefadroxil antibiotic by an analytical methodDetermination of cefadroxil antibiotic by an analytical method
Determination of cefadroxil antibiotic by an analytical method
 
Separation of L-Phenylalanine by Solvent Sublation and Solvent Extraction Method
Separation of L-Phenylalanine by Solvent Sublation and Solvent Extraction MethodSeparation of L-Phenylalanine by Solvent Sublation and Solvent Extraction Method
Separation of L-Phenylalanine by Solvent Sublation and Solvent Extraction Method
 
Null 6
Null 6Null 6
Null 6
 
Determination of Sugars, Bioproducts & Degradation Products in Liquid Fractio...
Determination of Sugars, Bioproducts & Degradation Products in Liquid Fractio...Determination of Sugars, Bioproducts & Degradation Products in Liquid Fractio...
Determination of Sugars, Bioproducts & Degradation Products in Liquid Fractio...
 
G0342034037
G0342034037G0342034037
G0342034037
 
Publications-Indian_drugs__2016[1]-Mohan
Publications-Indian_drugs__2016[1]-MohanPublications-Indian_drugs__2016[1]-Mohan
Publications-Indian_drugs__2016[1]-Mohan
 
Carbon-14 labelled ADCs and Peptides by Sean L Kitson
Carbon-14 labelled ADCs and Peptides by Sean L KitsonCarbon-14 labelled ADCs and Peptides by Sean L Kitson
Carbon-14 labelled ADCs and Peptides by Sean L Kitson
 
J comb chem
J comb chemJ comb chem
J comb chem
 
Simultaneous estimation and validation for gliclazide(yachita)
Simultaneous estimation and validation for gliclazide(yachita)Simultaneous estimation and validation for gliclazide(yachita)
Simultaneous estimation and validation for gliclazide(yachita)
 
LC-MS/MS method for the quantification of carbinoxamine in human plasma
LC-MS/MS method for the quantification of carbinoxamine in human plasmaLC-MS/MS method for the quantification of carbinoxamine in human plasma
LC-MS/MS method for the quantification of carbinoxamine in human plasma
 
NRFPRESENTATIONNEWSAIP1finallypresentation13july
NRFPRESENTATIONNEWSAIP1finallypresentation13julyNRFPRESENTATIONNEWSAIP1finallypresentation13july
NRFPRESENTATIONNEWSAIP1finallypresentation13july
 
020203 ps0096
020203 ps0096020203 ps0096
020203 ps0096
 
(37)
(37)(37)
(37)
 
Formulation and Evaluation of Atorvastatin Calcium Niosomes
Formulation and Evaluation of Atorvastatin Calcium NiosomesFormulation and Evaluation of Atorvastatin Calcium Niosomes
Formulation and Evaluation of Atorvastatin Calcium Niosomes
 
A novel reversed-phase liquid chromatographic method for the simultaneous det...
A novel reversed-phase liquid chromatographic method for the simultaneous det...A novel reversed-phase liquid chromatographic method for the simultaneous det...
A novel reversed-phase liquid chromatographic method for the simultaneous det...
 
DM Garby_Vitamin B6 AACC 2012
DM Garby_Vitamin B6 AACC 2012DM Garby_Vitamin B6 AACC 2012
DM Garby_Vitamin B6 AACC 2012
 
depolymerization-of-high-molecular-weight-into-a-predicted-low-molecular-weig...
depolymerization-of-high-molecular-weight-into-a-predicted-low-molecular-weig...depolymerization-of-high-molecular-weight-into-a-predicted-low-molecular-weig...
depolymerization-of-high-molecular-weight-into-a-predicted-low-molecular-weig...
 
Methyl phenidate
Methyl phenidate Methyl phenidate
Methyl phenidate
 
SYNTHESIS OF DRUG CARRIER POLYACRYLIC
SYNTHESIS OF DRUG CARRIER POLYACRYLICSYNTHESIS OF DRUG CARRIER POLYACRYLIC
SYNTHESIS OF DRUG CARRIER POLYACRYLIC
 
H0434555
H0434555H0434555
H0434555
 

En vedette

Social media analytics bod
Social media analytics bodSocial media analytics bod
Social media analytics bod
Stuart Meagher
 
Alimentacion saludable proyecto final
Alimentacion saludable proyecto finalAlimentacion saludable proyecto final
Alimentacion saludable proyecto final
vielkavasquez
 
What is electric current
What is electric currentWhat is electric current
What is electric current
N Chalkley
 
Testing the Power of Pointing
Testing the Power of PointingTesting the Power of Pointing
Testing the Power of Pointing
alexphilstrom
 
Bp holdings barcelona & madrid spain
Bp holdings barcelona & madrid spainBp holdings barcelona & madrid spain
Bp holdings barcelona & madrid spain
Jaantje Browning
 
How are cells_specialized_chapter_8_lesson_2
How are cells_specialized_chapter_8_lesson_2How are cells_specialized_chapter_8_lesson_2
How are cells_specialized_chapter_8_lesson_2
N Chalkley
 
Pj tahun 2 cempaka 2012
Pj tahun 2 cempaka 2012Pj tahun 2 cempaka 2012
Pj tahun 2 cempaka 2012
RoyIzwan Izwan
 

En vedette (17)

1 s2.0-s1570023203002794-main
1 s2.0-s1570023203002794-main1 s2.0-s1570023203002794-main
1 s2.0-s1570023203002794-main
 
informatica
informaticainformatica
informatica
 
Oci formally signs us$ 363 m contract in iraq
Oci formally signs us$ 363 m contract in iraqOci formally signs us$ 363 m contract in iraq
Oci formally signs us$ 363 m contract in iraq
 
Social media analytics bod
Social media analytics bodSocial media analytics bod
Social media analytics bod
 
Sp brochure
Sp brochureSp brochure
Sp brochure
 
Rpsb template
Rpsb templateRpsb template
Rpsb template
 
Alimentacion saludable proyecto final
Alimentacion saludable proyecto finalAlimentacion saludable proyecto final
Alimentacion saludable proyecto final
 
Andy Fazekas speech about Arena Platos
Andy Fazekas speech about Arena PlatosAndy Fazekas speech about Arena Platos
Andy Fazekas speech about Arena Platos
 
What is electric current
What is electric currentWhat is electric current
What is electric current
 
I b.tech -main exams time tables
I b.tech -main exams time tablesI b.tech -main exams time tables
I b.tech -main exams time tables
 
Retete de la GoodFood Romania BBQ Party #2
Retete de la GoodFood Romania BBQ Party #2Retete de la GoodFood Romania BBQ Party #2
Retete de la GoodFood Romania BBQ Party #2
 
Testing the Power of Pointing
Testing the Power of PointingTesting the Power of Pointing
Testing the Power of Pointing
 
Bp holdings barcelona & madrid spain
Bp holdings barcelona & madrid spainBp holdings barcelona & madrid spain
Bp holdings barcelona & madrid spain
 
Test presentation
Test presentationTest presentation
Test presentation
 
How are cells_specialized_chapter_8_lesson_2
How are cells_specialized_chapter_8_lesson_2How are cells_specialized_chapter_8_lesson_2
How are cells_specialized_chapter_8_lesson_2
 
Pj tahun 2 cempaka 2012
Pj tahun 2 cempaka 2012Pj tahun 2 cempaka 2012
Pj tahun 2 cempaka 2012
 
Luz maria rios
Luz maria riosLuz maria rios
Luz maria rios
 

Similaire à 1 s2.0-s0731708500002375-main

RP-HPLC method development and validation for simultaneous determination of d...
RP-HPLC method development and validation for simultaneous determination of d...RP-HPLC method development and validation for simultaneous determination of d...
RP-HPLC method development and validation for simultaneous determination of d...
BRNSSPublicationHubI
 
Determination of 3-chloropropanediol in soy sauce samples by liquid phase ext...
Determination of 3-chloropropanediol in soy sauce samples by liquid phase ext...Determination of 3-chloropropanediol in soy sauce samples by liquid phase ext...
Determination of 3-chloropropanediol in soy sauce samples by liquid phase ext...
International Multispeciality Journal of Health
 
Analytical chemistry
Analytical chemistryAnalytical chemistry
Analytical chemistry
nqkhanh1985
 
Diclofenac rabeprazole hplc
Diclofenac rabeprazole hplcDiclofenac rabeprazole hplc
Diclofenac rabeprazole hplc
Deepak Gadade
 
A Systematic Approach to Overcome the Matrix Effect during LC-ESI-MS/MS Analysis
A Systematic Approach to Overcome the Matrix Effect during LC-ESI-MS/MS AnalysisA Systematic Approach to Overcome the Matrix Effect during LC-ESI-MS/MS Analysis
A Systematic Approach to Overcome the Matrix Effect during LC-ESI-MS/MS Analysis
Bhaswat Chakraborty
 
In vitro and in vivo evaluation of positively charged liposaccharide derivati...
In vitro and in vivo evaluation of positively charged liposaccharide derivati...In vitro and in vivo evaluation of positively charged liposaccharide derivati...
In vitro and in vivo evaluation of positively charged liposaccharide derivati...
Adel Abdelrahim, PhD
 
Relative examination of monosaccharide and disaccharide
Relative examination of monosaccharide and disaccharideRelative examination of monosaccharide and disaccharide
Relative examination of monosaccharide and disaccharide
Alexander Decker
 

Similaire à 1 s2.0-s0731708500002375-main (20)

Supercritical fluid (CO2) chromatography for quantitative determination of se...
Supercritical fluid (CO2) chromatography for quantitative determination of se...Supercritical fluid (CO2) chromatography for quantitative determination of se...
Supercritical fluid (CO2) chromatography for quantitative determination of se...
 
RP-HPLC method development and validation for simultaneous determination of d...
RP-HPLC method development and validation for simultaneous determination of d...RP-HPLC method development and validation for simultaneous determination of d...
RP-HPLC method development and validation for simultaneous determination of d...
 
Sagar kanade m pharm indrustial project
Sagar kanade m pharm indrustial projectSagar kanade m pharm indrustial project
Sagar kanade m pharm indrustial project
 
Short chain fatty acids analysis
Short chain fatty acids analysisShort chain fatty acids analysis
Short chain fatty acids analysis
 
CHROMB17026[1]
CHROMB17026[1]CHROMB17026[1]
CHROMB17026[1]
 
Sample preparation and protocols in metabolite identification
Sample preparation and protocols in metabolite identificationSample preparation and protocols in metabolite identification
Sample preparation and protocols in metabolite identification
 
Determination of 3-chloropropanediol in soy sauce samples by liquid phase ext...
Determination of 3-chloropropanediol in soy sauce samples by liquid phase ext...Determination of 3-chloropropanediol in soy sauce samples by liquid phase ext...
Determination of 3-chloropropanediol in soy sauce samples by liquid phase ext...
 
A Simple and Validated RP-HPLC Method for the Estimation of Methylcobalamin i...
A Simple and Validated RP-HPLC Method for the Estimation of Methylcobalamin i...A Simple and Validated RP-HPLC Method for the Estimation of Methylcobalamin i...
A Simple and Validated RP-HPLC Method for the Estimation of Methylcobalamin i...
 
HPLC (RP-HPLC) Method Development for simultaneous estimation of EMP & LNG
HPLC (RP-HPLC) Method Development for simultaneous estimation of EMP & LNGHPLC (RP-HPLC) Method Development for simultaneous estimation of EMP & LNG
HPLC (RP-HPLC) Method Development for simultaneous estimation of EMP & LNG
 
Analytical chemistry
Analytical chemistryAnalytical chemistry
Analytical chemistry
 
IOSR Journal of Pharmacy (IOSRPHR)
IOSR Journal of Pharmacy (IOSRPHR)IOSR Journal of Pharmacy (IOSRPHR)
IOSR Journal of Pharmacy (IOSRPHR)
 
Diclofenac rabeprazole hplc
Diclofenac rabeprazole hplcDiclofenac rabeprazole hplc
Diclofenac rabeprazole hplc
 
Simultaneous estimation of meclizine and nicotinic acid by using RP-HPLC
Simultaneous estimation of meclizine and nicotinic acid by using RP-HPLCSimultaneous estimation of meclizine and nicotinic acid by using RP-HPLC
Simultaneous estimation of meclizine and nicotinic acid by using RP-HPLC
 
Method development and validation for the simultaneous estimation of sitaglip...
Method development and validation for the simultaneous estimation of sitaglip...Method development and validation for the simultaneous estimation of sitaglip...
Method development and validation for the simultaneous estimation of sitaglip...
 
A Systematic Approach to Overcome the Matrix Effect during LC-ESI-MS/MS Analysis
A Systematic Approach to Overcome the Matrix Effect during LC-ESI-MS/MS AnalysisA Systematic Approach to Overcome the Matrix Effect during LC-ESI-MS/MS Analysis
A Systematic Approach to Overcome the Matrix Effect during LC-ESI-MS/MS Analysis
 
In vitro and in vivo evaluation of positively charged liposaccharide derivati...
In vitro and in vivo evaluation of positively charged liposaccharide derivati...In vitro and in vivo evaluation of positively charged liposaccharide derivati...
In vitro and in vivo evaluation of positively charged liposaccharide derivati...
 
Green analytical techniques used in pharmaceutical analysis
Green analytical techniques used in pharmaceutical analysisGreen analytical techniques used in pharmaceutical analysis
Green analytical techniques used in pharmaceutical analysis
 
Bioanalytical method development and validation .
Bioanalytical method development and validation .Bioanalytical method development and validation .
Bioanalytical method development and validation .
 
Enhancing Volatile Organic Compounds in Water
Enhancing Volatile Organic Compounds in Water Enhancing Volatile Organic Compounds in Water
Enhancing Volatile Organic Compounds in Water
 
Relative examination of monosaccharide and disaccharide
Relative examination of monosaccharide and disaccharideRelative examination of monosaccharide and disaccharide
Relative examination of monosaccharide and disaccharide
 

Plus de Narayana Reddy Palakollu (11)

1 s2.0-s0039914097002452-main
1 s2.0-s0039914097002452-main1 s2.0-s0039914097002452-main
1 s2.0-s0039914097002452-main
 
1 s2.0-s0022072896048048-main
1 s2.0-s0022072896048048-main1 s2.0-s0022072896048048-main
1 s2.0-s0022072896048048-main
 
elective determination of L-dopa in the presence of uric acid and ascorbic ac...
elective determination of L-dopa in the presence of uric acid and ascorbic ac...elective determination of L-dopa in the presence of uric acid and ascorbic ac...
elective determination of L-dopa in the presence of uric acid and ascorbic ac...
 
1 s2.0-s0731708505002189-main
1 s2.0-s0731708505002189-main1 s2.0-s0731708505002189-main
1 s2.0-s0731708505002189-main
 
R 13 regulations b tech ist year syllabi of all branches 12 sept 13
R 13 regulations b tech ist year syllabi of all branches 12 sept 13R 13 regulations b tech ist year syllabi of all branches 12 sept 13
R 13 regulations b tech ist year syllabi of all branches 12 sept 13
 
Engineering Chemistry syllabus
Engineering Chemistry syllabusEngineering Chemistry syllabus
Engineering Chemistry syllabus
 
Science of corrosion
Science of corrosionScience of corrosion
Science of corrosion
 
WATER
WATERWATER
WATER
 
Syllabus
SyllabusSyllabus
Syllabus
 
Appscj unior lecturerspreviouspaperswithexplanations
Appscj unior lecturerspreviouspaperswithexplanationsAppscj unior lecturerspreviouspaperswithexplanations
Appscj unior lecturerspreviouspaperswithexplanations
 
I b.tech -main exams time tables
I b.tech -main exams time tablesI b.tech -main exams time tables
I b.tech -main exams time tables
 

Dernier

+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
?#DUbAI#??##{{(☎️+971_581248768%)**%*]'#abortion pills for sale in dubai@
 
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Victor Rentea
 

Dernier (20)

FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
 
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
 
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
 
MINDCTI Revenue Release Quarter One 2024
MINDCTI Revenue Release Quarter One 2024MINDCTI Revenue Release Quarter One 2024
MINDCTI Revenue Release Quarter One 2024
 
Rising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdf
Rising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdfRising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdf
Rising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdf
 
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
 
ICT role in 21st century education and its challenges
ICT role in 21st century education and its challengesICT role in 21st century education and its challenges
ICT role in 21st century education and its challenges
 
"I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ..."I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ...
 
Elevate Developer Efficiency & build GenAI Application with Amazon Q​
Elevate Developer Efficiency & build GenAI Application with Amazon Q​Elevate Developer Efficiency & build GenAI Application with Amazon Q​
Elevate Developer Efficiency & build GenAI Application with Amazon Q​
 
Strategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a FresherStrategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a Fresher
 
Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...
Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...
Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...
 
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
 
MS Copilot expands with MS Graph connectors
MS Copilot expands with MS Graph connectorsMS Copilot expands with MS Graph connectors
MS Copilot expands with MS Graph connectors
 
CNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In PakistanCNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In Pakistan
 
Apidays New York 2024 - APIs in 2030: The Risk of Technological Sleepwalk by ...
Apidays New York 2024 - APIs in 2030: The Risk of Technological Sleepwalk by ...Apidays New York 2024 - APIs in 2030: The Risk of Technological Sleepwalk by ...
Apidays New York 2024 - APIs in 2030: The Risk of Technological Sleepwalk by ...
 
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
 
Artificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : UncertaintyArtificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : Uncertainty
 
WSO2's API Vision: Unifying Control, Empowering Developers
WSO2's API Vision: Unifying Control, Empowering DevelopersWSO2's API Vision: Unifying Control, Empowering Developers
WSO2's API Vision: Unifying Control, Empowering Developers
 
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost SavingRepurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
 

1 s2.0-s0731708500002375-main

  • 1. Journal of Pharmaceutical and Biomedical Analysis 22 (2000) 613–624 Short communication Simultaneous determination of levodopa, carbidopa and their metabolites in human plasma and urine samples using LC-EC Kamal A. Sagar, Malcolm R. Smyth * School of Chemical Sciences, Biomedical and En6ironmental Sensor Technology Centre, Dublin City Uni6ersity, Dublin 9, Ireland Received 10 May 1999; received in revised form 16 September 1999; accepted 19 September 1999 Abstract In this study levodopa (L-DOPA), carbidopa (C-DOPA) and their metabolites were resolved from other endogenous components present in human plasma and urine and determined quantitatively. The developed technique involved the use of a second pump, a switching valve, and a pre-column in the LC system in order to perform on-line sample clean-up and enrichment. This procedure is dependent on an effective removal of the many interfering matrix components that vitiate HPLC analysis. Several unknown endogenous electroactive compounds, present in plasma, were eliminated by the purification step, or suppressed by the pre-treatment or detection conditions. The analyses were separated on an Octyl-bonded reversed-phase column followed by amperometric detection using a carbon fibre microelectrode flow cell operated at +0.8 V versus silver/silver phosphate reference electrode. The cell was compatible with the mobile and the stationary phase used in the flow system without any complex surface reaction. The peak currents obtained for the different analytes were directly proportional to the analyse over the concentration range 0.02–4.0 mg ml−1 . Using this method, the minimum detectable concentration was estimated to be 5 and 8 ng ml−1 for L-DOPA and C-DOPA, respectively. Recovery studies performed on human plasma samples ranged from 93.83 to 89.76%, with a relative standard deviation of B6%. The intra- and inter-assay coefficients of variation were B7%. The accuracy of the assay, which was defined as the percentage difference between the mean concentration found and the theoretical (true) concentration, was 12% or better. The electrochemical pre-treatment regime described in this work permitted a longer application of the same microelectrode. The method showed a good agreement with other available methods described in the introduction and offers the advantages of being simple, less time and labour consuming, does not require additional solvents for extraction, inexpensive and suitable for routine analysis and kinetic purposes. © 2000 Elsevier Science B.V. All rights reserved. Keywords: Levodopa; Carbidopa; 3-orthomethyl dopa; 3-ortho carbidopa; Human plasma profiles; Urine concentration; Reversed- phase liquid chromatography; Amperometric detection; Carbon fibre flow cell www.elsevier.com/locate/jpba * Corresponding author. Tel.: +353-1-7045308; fax: +353-1-7045032. E-mail address: smythm@ccmail.dcu.ie (M.R. Smyth) 0731-7085/00/$ - see front matter © 2000 Elsevier Science B.V. All rights reserved. PII: S0731-7085(00)00237-5
  • 2. K.A. Sagar, M.R. Smyth / J. Pharm. Biomed. Anal. 22 (2000) 613–624614 1. Introduction Parkinsonism, first described by Parkinson in 1817, is characterised by rigidity, tremor and bradykinesia. The observation that the transmitter dopamine in basal ganglia is markedly decreased in Parkinson’s disease (PD) [1] lead to the devel- opment of its metabolic precursor levodopa (L- DOPA) (3,4-di-hydroxy phenyl alanine) (Fig. 1), initially alone [2] and later combined with periph- eral decarboxylase inhibitors (e.g. benserazide and carbidopa (C-DOPA)) as a substitution therapy used in combination to treat PD [3–6]. By reduc- ing daily L-DOPA dosage requirements in this manner, the addition of C-DOPA also reduces the side effects associated with L-DOPA administra- tion. C-DOPA (S,h-hydrazino-3,4-dihydroxy-h- methyl-benzene propionic acid; Fig. 1) is the hydrazino derivative of methyldopa, which in- hibits the decarboxylation of L-DOPA in periph- eral tissues and, thus, allows a greater amount of the L-DOPA dose to be transported into the central nervous system and increases its accessibil- ity to nigrostriatal sites of action in the brain. A change in the concentration of one or both drugs in the body may influence the bioavailability and biopharmaceutic properties of the pharmaceutical preparation and subsequently their magnitude of action [7]. The treatment using these drugs provide symptomatic relief to most patients at the initial stages of disease, although unpredictable symptom fluctuations in the effect of these drugs are seen in advanced stages of the disease. The finding that fluctuations in motor performances of patients with PD receiving L-DOPA in combina- tion with the aromatic amino acid decarboxylase inhibitors carbidopa or benserazide, are a major problem in the treatment of this disorder and a constant plasma concentration of these drugs sta- bilises the symptoms [7–9] have focused interest on developing different methods to monitor simultaneously the concentration of these drugs in biological fluids to assist in the management of this disease. One of the most significant advances in quantitation techniques has been the develop- ment of electrochemical detectors combined with HPLC (LC-EC), which offers the capability of selective and sensitive determination of electroac- tive oxidizable or reducible drug products, with little interference from biological matrix interfer- ences [10] and with low limits of detection down to picogram quantities [11]. Few detection meth- ods used can compare for simplicity and perfor- mance [11]. Of the numerous methods [12–29] reported for the determination of these drugs in biological fluids, few permit a simultaneous quan- titative determination of both drugs and their metabolises in biological fluids. Some of these procedures are difficult to set up, expensive and require great care in maintaining satisfactory con- trols [18]. However, there is no general agreement as to their extraction and clean-up procedures from biological fluids [19]. Radioenzymatic assays involve conversion of DOPA to dopamine, and the intrinsic dopamine must be subtracted from the final volume [14,15]. Some of these assays proposed for clinical use were developed using biological fluids obtained from animals. Experi- mental animals are usually kept under much more controlled conditions than people live in. Conse- quently chromatograms of extracts of biological fluids from animals tend to be more reproducible and cleaner than those from people and may be misleading. HPLC methods used for the simulta- neous determination of these compounds in rat brain were sensitive, but they were not selective enough to be applied to complex biological sam- ples, such as urine and plasma, even when the samples were purified by extraction with an or- ganic solvent [20,21], acid-washed alumina [22,24] or boric acid gel [23,28,29]. Other methods have relied upon alumina extraction for separation of cathecol compounds [24], with a separate ion-ex- change isolation step for OMD and other O- methylated cathecol metabolites or, because of similar retention times of OMD and C-DOPA, have been unable to resolve the two in clinical Fig. 1. Basic structural formulae of levodopa (a) and car- bidopa (b).
  • 3. K.A. Sagar, M.R. Smyth / J. Pharm. Biomed. Anal. 22 (2000) 613–624 615 samples [17,25]. The procedure using aluminium oxide, however, has several disadvantages; it is a complicated and time-consuming task, there is difficulty in activation of aluminium oxide and there is low recovery. Gas-chromatographic methods have been described [26,27], but these involve the inconvenience of multiple derivatiza- tion. In view of the importance of determining these drugs in human plasma as a tool in under- standing the pharmacotherapy in PD, we present in this paper a selective and sensitive analytical procedure for the quantitation of L- DOPA, C-DOPA, and their active metabolites in human plasma using a carbon fibre micro- electrode flow cell previously reported by our laboratory [30], in combination with an auto- mated column switching assembly which in- cluded the use of two columns to extract and resolve the major drugs components and their metabolites in human plasma and urine. The use of two columns allowed the co-elution of the analytes from the first column, but are separated from the excess reagent and other side products in the sample. The peaks of interest are then switched to the second column where they are separated from each other. This particular type of column switching is often referred to as ‘heart-cutting’ [31]. To our knowledge such pro- cedures have not been reported previously for the determination of these drugs and their metabolites simultaneously in biological fluids. The convenience of our method is facilitated by its rapidity, ease of sample preparation by using a fast single-extraction and enrichment step, and the use of a low cost commercially available carbon fibre. These advantages are of important consideration in performing bioavailability stud- ies or in clinical routine analysis involving a large number of plasma samples. 2. Experimental 2.1. Chemicals and reagents All reagents and chemicals were ACS Reagent Grade and were used without purification. Sodium dihydrogen orthophosphate was pur- chased from Fluka (Buchs, Switzerland). Or- thophosphoric acid was supplied by BDH (BDH, Poole, Dorset, UK). All other chemicals were obtained from Sigma (Pool, Dorset, UK). Water was distilled and then further purified by passing through a Milli-Q water purification sys- tem (Millipore, Milford, MA, USA). Plasma samples were obtained from normal human vol- unteers. Heparinized plastic tubes used for whole blood collection ‘LiHeparin Menovette’, were supplied by Sarstedt (Numbrecht, Ger- many). Carbon fibres, 14 mm in diameter, were obtained from AVCO (Lowell, MA, USA). The surface of these fibres has no external coating. Silver epoxy was purchased from RS compo- nents (Corby, Northants, UK) and the glassy carbon used in the comparison studies was ob- tained from EG&G Princeton Applied Research (Princeton, NJ, USA). 2.2. HPLC-mobile phase The mobile phase used was a mixture of 16.5 g of sodium dihydrogen orthophosphate, 980 ml of water, 1.0 ml of 0.10 M disodium ethylenedi- amine tetra-acetic acid (EDTA), 20 ml of methanol and 1.2 ml of 0.5 mM sodium hep- tanesulphonate (HAS) with the pH adjusted to 3.4 with 1 M orthophospharic acid. The mobile phase was filtered through a pore size 0.45 mm cellulose membrane filter (HVLP, Millipore, Bedford, MA, USA), degassed under reduced pressure and used at ambient temperature. With a flow-rate of 1 ml min−1 , the elution using this mobile phase was carried out at this tempera- ture. The EDTA was used to sequester any oxi- disable metal ions. 2.3. HPLC-columns An Octyl-bonded/reversed phase column (12.5 cm×4.0 mm I.D. 5-mm particle size, Lichrosorb RP-8 Hibar) was used for the purpose of the purification of deproteinized plasma and urine samples as well as for preconcentration of the different analytes. The second column, 25.0 cm×4.0 mm I.D. 5-mm reversed-phase column (Ultrasphere), was used for the separation of the
  • 4. K.A. Sagar, M.R. Smyth / J. Pharm. Biomed. Anal. 22 (2000) 613–624616 Fig. 2. Sketch of the flow pattern through the column switch- ing system, used for retaining the analyses in the pre-concen- tration column (a) and eluting the drugs from the pre-concentration column (b). 2.4. Equipment Plasma centrifugation was performed on a Mi- crofuge 12 microcentrifuge from Beckman Instru- ments (Fullerton, CA, USA). All analyses were performed on HPLC waters system consisted of two pumps (Waters Model 501). Sample introduc- tion was via a Rheodyne (Cotate, CA, USA) Model 7125 injection valve, fitted with a 25 ml loop for direct injection. For the purpose of ex- traction by column switching, the injection was fitted with a l ml loop and a second pump (pump A), and the concentration column was connected to the analytical assembly via a Rheodyne Model 7000 six-port switching valve. Fig. 2 illustrates schematically the configuration of the column- switching system at the valve positions A and B. At position A, the loading/washing eluent deliv- ered by pump A eluted the gross plasma interfer- ents to waste, whereas the drugs and their metabolites were completely retained. When the valve rotated to position B, the analytes were swept onto the concentration column by the mo- bile phase where it was separated and subse- quently detected. Oxidative amperometric measurements were performed using a Model 400 EC potentiostat (EG&G Princeton Applied Re- search) connected to the flow cell by crocodile clips. The resultant signals were recorded on a Philips Model PM 8261 x-t recorder (Eindhoven, The Netherlands) at a chart speed of 33 mm h−1 . The peak currents (measured as peak heights on the recorder) as a function of concentration were then measured for quantitative analysis. 2.5. Fabrication of micro-electrode flow cell The micro-electrodes used were fabricated from carbon fibres, the diameter of which is 14 mm. There are two prominent features of the electro- chemistry attained at these electrodes: first, their small size results in predominantly diffusion-con- trolled currents that are time-independent within a very short time of the initial application of potential; secondly, surface conditions can con- tribute significantly to the electrochemical reac- tions at the electrode. The method of inserting the carbon fibre into a polyethylene tube is shown in compounds eluted from the concentration column. A 2 mm pre-column filter (Rheodyne) was also used. The column was normally operated at a back-pressure of 93 bar. The analytical column was primed by recycling the mobile phase overnight at a flow-rate of 0.3 ml min−1 At the end of a use period, the column was washed free of mobile phase components with 400–500 ml of water and then was returned by means of a gradient to 70% methanol for storage. The column in use retained good efficiency and resolu- tion for over 6 months despite prolonged expo- sure to aqueous solutions, and the matrix effects of the biological samples used.
  • 5. K.A. Sagar, M.R. Smyth / J. Pharm. Biomed. Anal. 22 (2000) 613–624 617 Fig. 3(a). The needle holes were sealed by gently heating with an electric iron. The construction of the counter electrode was described previously [30]. The working, reference, and counter elec- trode were mounted in a T-tube arrangement (Fig. 3(b)), and the working electrode was con- nected to the outlet of the HPLC column (down- stream of the working electrode). Hence the mobile phase eluent passed first through the working electrode and then via the counter elec- trode to waste. Placing the auxiliary electrode in this position reduces the uncompensated resis- tance to negligible value even with the low ionic strength of the mobile phase in use. With such a low uncompensated resistance the interfacial elec- trode potential is not significantly influenced by sample concentration, and a wide linear range was obtained. 2.6. Optimisation of detection potential In order to determine the optimum applied potential for both drugs, hydrodynamic voltam- mograms were obtained by repeated injections of 40 ng ml−1 L-DOPA and C-DOPA standard solutions into the chromatography system and recording the peak currents, at fixed applied po- tentials versus Ag/Ag3PO4. The detector operating oxidation voltage was increased from roughly 0.2 to 1.2 V in 0.2 V increments. 2.7. Standard solutions and linearity Plasma standards were prepared from blank human plasma spiked with L-DOPA, C-DOPA, and their metabolites (3-OMD, and 3-OMC), in the range 0.02–4 mg ml−l , which is enough to cover the range of expected patient values (usually up to 3.5 mg ml−1 . The working dilutions were divide into aliquots, which were frozen immedi- ately at−70°C, protected from light for maxi- mum stability, till used for analysis. Each calibration point was run in triplicate over five consecutive days, and the observed coefficient of variation (C.V.) for each standard curve was cal- culated from the least-squares regression equa- tions. The overall performance of the system was verified periodically by injection of standard samples. 2.8. Extraction reco6ery The extraction efficiency and recovery of the assay was assessed at concentrations of 0.5, 1.0 and 1.5 mg ml−1 . Six replicates of each concentra- tion containing the two compounds in human plasma were injected into the column and ex- tracted according to the method described. The recovery of both drugs from plasma was assessed by comparing the peak current of the extracted plasma samples with the peak current of authentic (unextracted, aqueous) standards, which were di- rectly injected (i.e. without column switching) onto the analytical column at the concentration levels, and the assay recovery was calculated using the following equation: % recovery =(mean peak height plasma extract) /(mean peak height standard)×100 2.9. Specificity of the method In order to examine the presence of any inter- ferences from the active metabolites of both drugs and other impurities that might exist in the phar- Fig. 3. Structure of the carbon fibre micro-flow cell: (a) Method of fixing a carbon fibre into polyethylene tube. (b) Diagram of the carbon fibre micro-flow cell consisting of (1) silver wire coated with Ag3PO4, (2) reference electrode body, (3) internal reference solution, (4) T- tube, (5) ceramic rod, (6) stainless-steel counter electrode and (7) fibre flow electrode.
  • 6. K.A. Sagar, M.R. Smyth / J. Pharm. Biomed. Anal. 22 (2000) 613–624618 Fig. 4. Hydrodynamic voltammograms of levodopa ( ) and carbidopa ( ) obtained by injections of a standard solution prepared in the mobile phase into the chromatograph. Mobile phase: see text, pH 3.4; working electrode: 14 mm carbon fibre at different potentials versus Ag/Ag3PO4. of two electrons and two protons, yielding ortho- quinone. Fig. 4 shows the hydrodynamic voltam- mograms of L-DOPA and C-DOPA prepared in the mobile phase. The voltammograms represent a rapidly achieved mass transport steady state. Plot of applied potential (E) against peak current exhibited one wave for each drug and showed a distinct sigmoidal dependence upon applied po- tential. The magnitude of the current is directly proportional to the bulk concentration at every point along the voltammetric curve. The single anodic peak obtained in the range studied verifies that both compounds underwent a single oxida- tion process within this range and was also depen- dent on the change in pH, although it is often desirable to operate an electrochemical detector on the limiting current plateau; in this case it was advantageous to operate on the rising part of the curve. The lower the potential chosen, the lower the background current produced and better sen- sitivity is obtained. Higher potentials resulted in greater background current and the electrochemi- cal detector was unlikely to be useful for trace analysis as the background oxidation became ex- orbitant. A working potential of +0.8 V afforded a significant reduction in background current, which resulted in better signal-to-noise ratios and this potential was selected for the reminder of the LC-EC studies. 3.2. Separation of the analytes in human plasma Reversed-phase chromatography appears to be most useful in the analysis of mixtures of such substances which posses both acidic and basic organic functional groups. Deproteinized plasma samples were injected directly into the HPLC system; every four samples were followed by a standard. The first step in the set-up of the switch- ing/separation system involved the selection of a suitable pre- (or concentration) column, which would retain the analytes while other endogenous components are eluted to waste. Among the dif- ferent columns used for this purpose, an Octyl- bonded/reversed phase column (12.5 cm×4.0 mm I.D. 5 mm-particle size, Lichrosorb RP-8 Hibar) showed the most favourable retention characteris- tics for both drugs and their metabolites. The next maceutical preparation used in the method devel- oped. The sensitivities, retention times and extrac- tion recoveries for these two drugs were determined by the above procedures in the pres- ence of these substances at a concentration of 1 mg ml−1 . 2.10. Urine analysis Samples with 2.0 ml of chlorhexidine gluconate added as a preservative were acidified immediately to a pH of 2 with a 6 M HCl to increase the stability [11]. The samples were then deproteinised by the addition of 0.01 M HCl and l M perchloric acid, the mixture was vortexed and centrifuged at 630 g at 5°C for 20 min [12]. Before analysis, the samples were filtered through 0.22 mm cellulose filters (Millipore, Sergrate MI, Italy). 3. Results and discussion 3.1. Optimisation of oxidation potential Each of the analyses contains a phenol or cate- chol functionality, which can be easily detected by direct anodic oxidation at relatively low potential [11,32]. The detector operated in the amperomet- ric mode with a fixed potential sufficiently positive to force the ortho-hydroxy groups to undergo loss
  • 7. K.A. Sagar, M.R. Smyth / J. Pharm. Biomed. Anal. 22 (2000) 613–624 619 stage was to find two compatible eluents of differ- ent elutropic strengths; one should have a poor/ elution capability to concentrate the analyses on the pre-column, and a second strongly eluting solvent to elute the analytes off the pre-column and onto the analytical column. The washing eluent should also be miscible with the mobile phase, as even slight incompatibility could result in a slug of solvent travelling down the analytical column, partially carrying sample components which may cause band broadening. The use of a 0.05 M solution of perchloric acid allowed the purification of plasma samples by washing out neutral and acidic compounds while the analyses (containing amino groups) were retained by the pre-column. A wash time (defined as the length of time between injection and switching of the valve) of 1.5 min was found to be satisfactory to provide a good clean-up of the plasma components with- out causing the analytes to elute. Six replicate injections of plasma samples containing the differ- ent analyses yielded a relative standard deviation (RSD) 5% for each substance. The configura- tion of the LC-EC system, the size of the packing materials used in both columns and the choice of the suitable columns and mobile/washing eluents had reduced the back-pressure and pressure jumps caused by switching of two HPLC columns, and in return reduced the possibility of unacceptable baseline disturbances or any peak broadening usually caused by the use of large particles. Mem- ory effects, a usual problem occurring when using column switching chromatography, was never en- countered using such a configuration. Fig. 5 shows the chromatogram of a spiked plasma sample containing 0.3 mg ml−1 L-DOPA/ 3-OMD and 0.35 pg ml−1 C-DOPA/3-OMC. The figure clearly indicates that under the experimen- tal conditions, both drugs were well resolved from the endogenous plasma peaks flanking it and their main metabolites. The mobile phase was opti- mised by careful examination of all major vari- ables, including pH and ionic strength, to determine their influence on enhancing peak sepa- ration without prolonging the analysis time for each sample. In such separations, an acidic pH proves optimal and modest pH adjustments can produce significant changes in the retention time characteristics of these substances. The pH se- lected for the mobile phase did not significantly alter the peak characteristics, even after 6 months of continuous use. There was no interference from the heparin and sodium metabisulphite, which are added to the blood as anticoagulant and antioxi- dant, respectively. The retention sequence for the different analyses can be explained due to the basis of the difference in the polarity. The primary amine levodopa elutes well before the less polar hydrazine-containing carbidopa. Methyl dopa and methylcarbidopa, due to the extra methyl group, are retained more, relative to L-DOPA and C- DOPA, respectively. The importance of separat- ing and detecting these metabolites lies in the side Fig. 5. A chromatogram obtained by direct injection of de- proteinized plasma sample containing L-DOPA, 3-OMD, C- DOPA and 3-OMC. Peaks: 1=L-DOPA; 2=3-OMD; 3=C-DOPA; 4=3-OMC.
  • 8. K.A. Sagar, M.R. Smyth / J. Pharm. Biomed. Anal. 22 (2000) 613–624620 Fig. 6. Chromatograms of 0.3 mg ml−1 levodopa obtained by analysing the drug (A) before and (B) after electrochemical pre-treatment of the working electrode. effects caused by their presence during long term therapies. Side-effects (dyskinesia, on-off phenom- ena and psychoses) is attributed to the high levels of 3-OMD in plasma and/or the plasma 3-OMD/ L-DOPA ratio [33,34]. Furthermore, hypokinesia ( a situation associated with low plasma levels of L-DOPA) can occur due to a competition for transport across the blood–brain barrier between L-DOPA and 3-OMD [35], and the determination of O-methylated products might be of clinical significance in psychiatric disorders [36]. Other metabolic pathways are unimportant [37]. 3.3. Pre-treatment of the micro-electrode Due to its inherent surface characteristics, car- bon often exhibits poor electron-transfer kinetics. This seems to be especially true for analysis of anionic species. Since the voltammetric response at carbon surfaces often degrades at an enhanced rate when placed in biological media, presumably due to adsorption of large molecules to the elec- trode surface, a process is required to renew the carbon surface before obtaining electrochemical information. The surface of the electrode used often changed after several runs (Fig. 6(a)). One reason for such changes is due to either the ad- sorption of species from solution or chemical changes which could have occurred on the elec- trode surface itself possibly because of the differ- ent reactions between the analyte and the electrode surface or due to a resultant by-product. These changes produced a high baseline noise resulted in variations in sensitivity, reproducibility and selectivity. A variety of methods have been used in the past by different workers, among these was laser treatment of the working electrode [38] and electrochemical pre-treatment [39]. The latter was preferred due to the configura- tion of the system and the availability of such treatment within the system used. Anodisation of the microelectrode at +1.0 V for 60 s, then cathodisation at −1.0 V for another minute, followed by equilibration at the working potential for 5 min was enough to remove any surface contaminants or inhibitory layers which hindered transport of electrons and oxidation of the species at the electrode surface. The activation of the
  • 9. K.A. Sagar, M.R. Smyth / J. Pharm. Biomed. Anal. 22 (2000) 613–624 621 electrode surface as a result of the pre-treatment process can produce quinoidal functionalities and improve the current response [40]. Fig. 6b illus- trates clearly the influence of the pre-treatment regime in the base-line noise and the signal-to- noise ratio level. 3.4. Method e6aluation 3.4.1. Linearity and detection limits Linear calibration graphs of peak heights of the standards, versus the concentration of the stan- dards were constructed by analysing spiked blank plasma over five days in the concentration range 0.02–4.0 mg ml−1 . This concentration range is within the therapeutic levels for these drugs [7,41–43]. The resulting current was directly pro- portional to the concentration of the oxidisable species. The plotted points represented the means of at least five replicate injections per standard. The curves showed a good linearity between the detector response and the analyte concentration. For each of the five regression lines the correla- tion coefficients (r2 ) were all greater than 0.993. The coefficient of variation of the slopes (n=5) of the regression lines calculated from the least squares regression equations, ranged from 3.0– 8.74%, with intercepts all close to zero. The sensitivity of the method is often expressed as the limit of detection (LOD). The LOD for the analysis is defined as the standard deviation of the base line noise. The measurement of the base line noise is not ambiguous and a more useful way to describe the sensitivity when blood or urine sam- ples are analysed could be to calculate the instru- mental limit of detection (ILOD) and the limit of quantitation (LOQ). The ILOD is the amount of an analyse giving a peak height three times the standard deviation of the base line noise without any matrix interference, whereas the LOQ is the concentration of an analyse in the matrix that could be determined with a precision (a signal-to- noise ratio of 3) under the given analytical proce- dure. In our case the ILOD for L-DOPA and C-DOPA was found to be 5 and 8 ng ml−1 , respectively. The LOQ was ca. 8 ng ml−1 for L-DOPA and 10 ng ml−1 for C-DOPA. This limit of quantitation is adequate for clinical analysis and pharmacotherapeutic studies and comparable to those values obtained by previous workers [3,6,44–46]. The use of relatively low potential, incorporation of reference and auxiliary elec- trodes in the same cell and recycling of the mobile phase, all resulted in reduction of the back- ground noise and improved LOD and LOQ values. 3.5. Precision and extraction reco6ery The column switching technique usually gives better precision than the traditional direct injec- tion technique for micro-samples [47]. The preci- sion of the method based on peak-height measurements was evaluated by replicate injection exhibited a coefficient of variation of B6.0%. Peak-height measurements were found to yield the same reproducible results as peak-area determina- tions, and there was no need to include an inter- nal standard in the analysis due to the good recovery and reproducibility obtained. The mean absolute recovery achieved with the described ex- traction procedure was always greater than 91.0% for L-DOPA and 89% for C-DOPA. Table 1 illustrates the precision and extraction recovery for both drugs using the technique described. 3.6. Selecti6ity of the method The possible potential various foreign com- pounds were studied; these compounds were se- lected according to (a) compounds which can be present as impurities in combination with the drugs in different pharmaceutical formulations and affect the analytical process and (b) other drugs that might be administered with these drugs. United States Pharmacopoeia (USP) [48] specifies methyl dopa, 3-methoxy tyrosine, and 3-O-methyl carbidopa as impurities in the analy- sis of L-DOPA–C-DOPA combination formula- tions. Interference from some of these substances in the determination of the drugs was tested in two different studies using the proposed tech- nique. The separation peak height, retention times and the recovery of the analyses were not affected by the presence of these substances. Errors B2% were calculated by comparing the results with the
  • 10. K.A. Sagar, M.R. Smyth / J. Pharm. Biomed. Anal. 22 (2000) 613–624622 Table 1 Precision and extraction recovery Mean concentration found (mgConcentration added (mgCompound Recovery (%) Coefficienta of variation Accuracyb (%)ml−l )ml−l ) 0.459 91.83L-DOPA 4.700.5 4.10 1.0 0.925 92.50 3.92 7.50 1.407 93.86 3.101.5* 9.30 0.449 89.80C-DOPA 5.200.5 5.10 0.913 91.311.0 4.63 8.70 1.5* 1.387 92.47 3.75 11.30 a Mean of six samples from single plasma pool assayed in triplicate. b The percentage difference between the mean concentration found and the theoretical concentration. * Highest concentrations observed in clinical samples. corresponding results obtained with a solution containing only both drugs. Other drugs such as tricyclic antidepressants (Desipramine) that might be co-administered with both drugs was not ob- served under the experimental conditions. The selectivity and the resolution of the column was enhanced by the use of an ion pairing species (HSA), and by the admixture of an organic modifier such as methanol in the mobile phase. 3.7. Inter- and intra-assay 6ariability Within-day variabilities were established for five different days concentrations (0.25, 0.5 and l.5 mg ml−1 ) for dopa and carbidopa by adding the drugs to blank plasma over five consecutive days. Peak current values were interpolated on the individual regression lines to yield three new val- ues of amount found at each concentration level for every day. Between-day variability was then calculated by obtaining the mean C.V (%). Re- sults from this experiment are presented in Table 2, and they show that the overall assay variations at 0.25, 0.5 and l.5 mg nl−1 were B7% for both drugs. 3.8. Stability studies The stability of the electrode is of importance in order to define the period of time over which the electrode can be used without a significant de- crease in the sensitivity. After 1 week it was observed that a significant decrease in the sensitiv- ity has occurred even with the use of the electro- chemical pre-treatment procedure. The electrode response was at 45% of its initial value, with relative standard deviations greater than 13%. The amperometric detector was left on as long as Table 2 Inter- and intra-assay variability Compound Intra-assayInter-assay C.V. (%)Concentrationa (mg ml−1 ) Concentration (mg ml−1 ) C.V. (%) 0.25 5.1 0.25 6.73Levodopa 0.50 4.70 0.50 5.91 3.561.50 4.541.50 0.255.34 6.860.25Carbidopa 0.50 4.55 0.50 5.34 1.50 3.21 1.50 4.23 a Individual values are the mean of three measurements.
  • 11. K.A. Sagar, M.R. Smyth / J. Pharm. Biomed. Anal. 22 (2000) 613–624 623 Table 3 Absolute recovery of L-DOPA and 3-OMD from urine sam- ples ConcentrationSubstance Mean concentration recovereda (mg ml−1 ) 2.0L-DOPA 1.87 3.0C-DOPA 2.81 a n=5. from other endogenous components present in urine or plasma, it is not so subject to sample loss during transfer stages as off-line methods, and can be useful in routine biomedical and clinical investigations of these drugs and their metabo- lites. A work involving the use of this method in studying the different pharmacokinetic parame- ters and estimation of drug bioavailability in pa- tients receiving different formulations containing a combination of these drugs and identification of impurities in these formulations will be conducted in our laboratory in the near future. References [1] W.C. Bowman, M.J. Rand, Text book of Pharmacology, 2nd edition, Blackwell Scientific Publications, Cambridge, 1980, pp. 18–19. [2] M. Da Prada, H. Keller, L. Pieri, R. Kettler, W. Haefely, Experientia 40 (1984) 1165–1304. [3] D. Titus, T. August, K. Yeh, R. Eisenhandler, W. Bayne, D. Musson, J. Chromatogr. 534 (1990) 87–100. [4] D. Deleu, S. Sarre, G. Ebinger, Y. Michotte, J. Pharm. Biomed. Anal. 11 (1993) 577–585. [5] The Merck Index, 12th Edition, Merck and Company Incorporated, NJ, US, 1996, pp. 292–293. [6] I. Rondelli, D. Acerbi, F. Mariotti, P. Ventura, J. Chro- matogr. B 653 (1994) 17–23. [7] K. Yeh, T. August, D. Bush, K. Lasseter, D. Musson, S. Schwartz, M. Smith, D. Titus, Neurology 39 (1989) 25– 38. [8] M. Marion, F. Stocchi, N. Quinn, Clin. Neuropharmacol. 9 (1986) 165–181. [9] J. Sage, L. Schuh, R. Heikkila, Clin. Neuropharmacol. 11 (1988) 36–44. [10] P.T. Kissinger, R.M. Riggin, R.L. Alcorn, L.D. Rau, Biochem. Med. 13 (1975) 299–306. [11] P.T. Kissinger, Anal. Chem. 489 (1977) 447A–456A. [12] T. Ishimitsu, S. Hirose, J. Chromatogr. 337 (1985) 239– 248. [13] T. Ishimitsu, S. Hirose, Anal. Biochem. 150 (1985) 300– 308. [14] G.A. Johnson, J.M. Green, R. Kupiecki, Clin. Chem. 24 (1978) 1927–1930. [15] G. Zurcher, M. Da Prada, J. Neurochem. 33 (1979) 631–639. [16] M.J. Brown, C.T. Dollery, Br. J. Clin. Pharmacol. 11 (1981) 79–83. [17] M.P. Beers, M. Stern, H. Hurtz, A. Scarpa, J. Chro- matogr. 336 (1984) 380–384. [18] L. Rentzlog, Acta. Physiol. Scand. 377 (1972) 1–3. [19] E. Nissinen, J. Taskinen, J. Chromatogr. 231 (1982) 459– 462. the mobile phase flowed through the column and the flow cell and the nature of the cell construc- tion made it very stable in the mobile phase with no leakage during its operating lifetime. The con- tinuous washing process extended the life of the cell and minimised the start-up time. The working electrode was replaced every 7 days, but as such an electrode can be easily and cost effectively replaced, this problem of decreasing in sensitivity is not of major consequence. Stability of urine samples kept in an ice bath was tested by making 5 consecutive injections of same urine sample over a period of approximately 3 h. There were no significant changes in the peak current between the first and the last samples. In addition, urine samples were stable for over a week when stored at −4°C. The recovery of the drugs from spiked urine samples was satisfactory (Table 3), and the concentration of the ‘spiked samples’ did not appear to influence the recovery of the residues in urine specimens. 4. Conclusions The results demonstrate that L-DOPA, C- DOPA and their metabolites can be effectively resolved and quantitated in biological samples with a single on-line extraction and enrichment step followed by amperometric detection by em- ploying a potential of +0.8 V at the working electrode. The micro-flow cell described here is simple to prepare and easy to manage. The cell has the advantage of small iR drop, virtually insignificant capacitive charging currents and a rapid mass transport to and from the working electrode. The method eliminates interferences
  • 12. K.A. Sagar, M.R. Smyth / J. Pharm. Biomed. Anal. 22 (2000) 613–624624 [20] T.G. Rosano, H.H. Brown, J.M. Meola, Clin. Chem. 7 (1981) 228–231. [21] A. Yoshioka, T. Sakai, Z. Tamura, J. Chromatogr. 227 (1982) 162–167. [22] A.H. Anton, D.F. Sayre, J. Pharmacol. Exp. Ther. 138 (1962) 360–375. [23] S. Higa, T. Suzuki, A. Hayashi, I. Tsuge, Y. Yamamura, Anal. Biochem. 77 (1977) 18–24. [24] J. O’Hanlon, H. Campuzano, S. Horvath, Anal. Biochem. 34 (1970) 567–581. [25] A. Baruzzi, M. Contin, F. Albani, R. Riva, J. Chro- matogr. 375 (1986) 165–169. [26] Y. Mizuno, Clin. Chim. Acta 74 (1977) 9–11. [27] C. Hansson, G. Agrup, H. Rorsman, A.M. Rosengren, J. Chromatogr. 162 (1979) 7–22. [28] H. Schott, E. Rudloff, P. Schmidt, R. Roychoudhury, H. Kossel, Biochemistry 12 (1973) 932–938. [29] H. Weith, J. Wiebers, P. Gilham, Biochemistry 9 (1970) 4396–4401. [30] K.A. Sagar, M.R. Smyth, J. Wilson, K. McLaughlin, J. Chromatogr. 659 (1994) 329–336. [31] M. Mifune, D. Krehbiel, J. Stobaugh, C. Riley, J. Chro- matogr. 496 (1989) 5570. [32] P. Kabra, L. Manton, Clinical Applications of Liquid Chromatography, Humana Press, New York, 1981, p. 253. [33] E. Rivera-Calimlim, D. Tandon, F. Anderson, R. Joynt, Arch. Neurol. 34 (1977) 228–232. [34] M.D. Muenter, N.S. Sharpless, G.M. Tyce, Mayo Clin. Proc. 47 (1972) 389–395. [35] A. Reches, S. Fahm, Ann. Neurol. 12 (1982) 267–271. [36] G. Marzullo, (1981) in Function and Regulation of Mon- amine Enzymes: Basic Clinical Aspects, Proceedings 2nd Conference, In: Usdin, E. Weinr, N., and Youdin, M. (eds), pp.665–673, MacMillan, London. [37] N. Sharpless, M. Muenter, G. Tyce, Clin. Chim. Acta 37 (1972) 359–369. [38] T.G. Sterlin, A.G. Ewing, Anal. Chem. 63 (1991) 194– 198. [39] J. Wang, P. Tuzhi, V.J. Villa, J. Electroanal. Chem. 234 (1987) 119–131. [40] T.E. Edmonds, J. Guoliang, Anal. Chim. Acta 151 (1983) 99–108. [41] P. Benetello, M. Furlanut, G. Zara, M. Baraldo, E. Hassan, Eur. Neurol. 33 (1993) 69–73. [42] A. Grahnen, S. Eckernas, C. Collin, A. Ling-Andersson, G. Tiger, M. Nilsson, Eur. Neurol. 32 (1993) 343–348. [43] E. Breberg, H. Lennernas, L. Paalzow, Pharm. Res. 11 (1994) 549–555. [44] M. Gerlach, N. Klaunzer, H. Przuntek, J. Chromatogr. 380 (1986) 379–385. [45] M. Da Prada, R. Kettler, G. Zurcher, R. Schaffer, W. Heafely, Eur. Neurol. 27 (1) (1987) 9–12. [46] Y. Michotte, M. Moors, D. Deleu, P. Herregodts, G. Ebinger, J. Pharm. Biomed. Anal. 5 (1987) 659–664. [47] C. Goewie, E. Hogendoorn, Sci. Total Environ. 47 (1985) 349–360. [48] The United States Pharmacopeia, 23rd Revision, Rand McNally, Taunton, MA, 1995, p. 270. .