Air Purification & Fume Extraction for Medical Applications- Sentry Air Systems
Medical-PPT
1. HI-TECH is ISO 9001:2008 Certified company. We are one of the
India’s leading company, specializing in clean air and containment
facilities for Medical Field in operation theatre .
Hi-tech' takes great pride in providing our products and services with
the goal of attaining the highest level of excellence and customer
satisfaction. We strive for consistency and reliability in the products that
we manufacture, and the highest level of workmanship possible. Our
range of products is made only with the highest quality parts and the
latest assembly and quality control techniques to ensure the long life of
our products. We have been able to become innovative in designing
equipment for better performance in accordance with the international
standard i.e. ISO- 14644, Fed Std. 209E, BS 5295-76 etc.
Whatever your needs in clean air and containment we are confident
that HI-TECH can provide a competitive engineered solution to meet
your requirements.
2.
3. Laminar flow ventilation is used in modern orthopaedic
operating theatres to reduce the number of infective organisms
present in the air, which may lead to post-operative infection of
the wound. This is of particular significance in joint prosthesis
surgery (such as knee replacement and hip replacement
surgery), where deep-seated post-operative infection may result
in poor patient outcomes and substantial costs, both to patients
and healthcare providers.
4.
5.
6.
7.
8.
9.
10.
11.
12. FEATURES:
•Class 5 and class 100 as per ISO 14644-1 and Fed Std 209E respectively.
•As per “NABH” Guidelines.
•Protective grills.
•Low noise levels (below 60db).
•Compact and unique design.
SPECIFICATIONS:
•MOC : S.S / CRCA powder coated/Painted.
•HEPA Filter: Imported glass fiber (fire retardant) media HEPA filer
eliminates 99.978% of all the particles down to 0.3 microns and above.
•Pre Filter: HDP washable and reusable arrests not less than 98% of
particles 10 micron and larger thus prolonging HEPA filter life.
•Motor: International Standard motor.
•Size: Different sizes as per your requirement.
13.
14. An isolation room is a specially constructed area in a hospital designed for
housing patients with an infectious disease in order to prevent the spread
of the disease in the hospital. Unlike a clean room, which is designed to
isolate the outside from the patient, the isolation room is designed to
isolate the patient from the rest of the world.
ISOLATION ROOMS (Negative pressure Room) is designed for
Infectious Patients such as
Influenza,Tuberculosis,sars,Varicella,MRSA,etc.
15.
16. Greater air pressure in the isolation room than in the adjacent corridor or
anteroom. To prevent transmission from the outside environment to
profoundly immunosuppressed persons/patients. Recirculation
Ventilation in which all or most of the air that is exhausted from an area
is returned to the same area or other areas of the facility.
ISOLATION ROOMS (Positive Pressure Room) is designed for
patients with weakened immune systems such as Oncology,
Hematology, Neonatology, transplant, Burn units, Operating Theatres,
ICU’s.
17.
18.
19. We are a leading manufacturers & Supplier of Modular Operation Theatre
Equipment such as Laminar Air Flow Unit, Wall Panels, O.T light, O.T Table,
Hermetically Door, O.T. Control Panel , X-ray Viewer and Pressure Relief
Damper from India.
20.
21.
22.
23. How does it work?
Ultra clean laminar airflow is directed directly over the surgical site and
instruments, acting as a barrier and minimizing the presence of bacteria-
carrying particles at the wound.
An easy to use control system helps the user direct airflow in the most
effective way: The airflow direction and the correct distance from the
surgical site will gives you maximum effect.
Ambient air is passed through a medical grade ULPA filtration (99.99%
efficient to .12 microns) filter combined with the germicidal disinfection
power of UVGI lamp. The ultra- clean air leaves the perforated screen as
a laminar (turbulence-free) flow, pushing contaminated air forwards away
from the risk zone and into the room, to be absorbed by the conventional
ventilation system.
24.
25. Used in ICCU, ICU, CANCER PATIENTS ROOM, TB
PATIENT ROOM, GENERAL WARDS, LABORATORY,
COMMERCIAL BUILDING, HAIR SALOON,
GYMNESIUM, HOMES, HOTELS, OFFICES, etc.
26. •Used in ICCU, ICU, GENERAL WARDS, HOMES,
HOTELS, CANCER PATIENTS ROOM etc.
27.
28.
29. SPECIFICATIONS:
•MOC : S.S / CRCA powder coated
•Motor: International Standard motor.
•Fan assembly: Dynamically Balanced Aluminum , directly driven, cross
flow Blowers are aero-dynamically spaced to obtain optimum tangential
velocity at blade tips which enables handling of large air volume at low
power consumption.
•Size: S.S : 3’, 3.25’, 4’, 5’, 6’.
CRCA : 2’, 2.5’, 3’, 4’, 5’.
30.
31.
32.
33.
34.
35. Baba Orthopedic Hospital- Dr. Mahesh Pandya , Vadodara.
Global Meridian- Dr.Sanjay Pandya
Shaili Endoscopy – Dr.Paresh Shah,Dhabhasa
Pranayam Hospital- Dr.Nirav Bhalani, Vadodara
Aashray Hospital - Dr. Aashit Shah , Vadodara.
Kaka Orthopedic, Vadodara.
Venus Hospital, Vadodara.
Dhiraj General Hospital , Vadodara.
Sai Krishna, Mehsana.
Dr. Piyush, Navsari.
Sangam Hospital, Vadodara.Dhruvpal Sisodia, Anand.
Haribhakti Aarogya mandir.
And many more………..