Constant updating of load spectra, evolution of standards, regulations, rules and calculation methods has increased the importance of seismic evaluation of NPP structures.
Few rules to be followed like:
•Equipments are classified as Class I, Class II and Class-III.
•ASME Section III Div 1 subsection NB, NC, ND based on the seismic safety class of the equipment.
•Supports qualified as per ASME section III Div 1 subsection NF.
2. engineering your designswww.pro-sim.com 2
Types of Seismic Vibrations
Natural Events
•Earthquakes
•Volcanoes
•Tsunami
•Microseisms
Man-made events
•Explosions
•Reservoir seismicity
•Rock burst (mines)
•Induced seismicity
•Cultural noise
Significance
Constant updating of load spectra, evolution of standards, regulations,
rules and calculation methods has increased the importance of seismic
evaluation of NPP structures.
3. engineering your designswww.pro-sim.com
Seismic Qualification (Earthquake)
•Equipments are classified as Class I, Class II and Class-III.
•ASME Section III Div 1 subsection NB, NC, ND based on the seismic
safety class of the equipment.
•Supports qualified as per ASME section III Div 1 subsection NF.
Rules
3
•Equipments are classified as:
•Passive equipments
•Active equipments
Passive equipments are qualified for structural integrity and active
equipments with an additional functional operability criteria.
8. engineering your designswww.pro-sim.com
4200 KW DG SET
8
Parts considered for
qualification:
- Base frame (skid)
- Engine crank case
- Alternator assembly
- Crank shaft
- Turbocharger support
- Turbocharger
- Fly wheel
- Flexible coupling
- Oil sump
•Allowable stress limits of
the material as per
manufacturer’s standard
engineering practice.
•Functional operability
checked
10. engineering your designswww.pro-sim.com
Load-1 = Engine dynamic forces
Load-2 = Alternator normal torque
Load-3 = Self/Dead weight
Load-4 = Loads due to seismic condition (OBE)
Load-5 = Loads due to seismic condition (SSE)
Load-6 = Short circuit load
LOAD COMBINATION FOR QUALIFICATION
•LC-1 = Loads under normal running condition
= Load-1+ Load-2 + Load-3
•LC-2 = Engine running + seismic (OBE)
= LC-1 + Load-4
•LC-3 = Engine running + seismic (SSE)
= LC-1 + Load-5
•LC-4 = Abnormal running condition = LC-1 + Load-6
10
LOADS AND COMBINATIONS (4.2 MW DG SET)
Alternator Load Application
11. engineering your designswww.pro-sim.com
Sloshing inside a tank (details)
11
•Eigen value analysis with missing mass
correction
•Dynamic analysis carried out for sloshing effects
•Housner model used to adequately represent
the behavior
•Shell qualified as per ASME Sec III, ND
•Supports qualified as per ASME Sec III, NF
•Embedded plate size checks
•Weld adequacy checks
•impulsive mass, mi
•convective mass, mc
•mass of water, mw
•height of mi from bottom, hi
•height of mc from bottom, hc
•maximum height of fluid, h
•spring stiffness, Kc
Sloshing effect modeling
13. engineering your designswww.pro-sim.com 13
•Visited site (RAPP) to check availability of usable EPs and
area around the building
•Designed the tower from scratch
•Strength design of columns.
•Strength design of bracings.
•Strength design of stacks.
•Strength design of structure foundation bolts.
•Strength design of structure base plate and gussets.
•Pull out shear failure mode of foundation.
LATTICE TOWER SUPPORTED CHIMNEY
3 exhaust pipes entering the tower Silencer arrangement on the roof Complete lattice tower
14. engineering your designswww.pro-sim.com 14
CONCLUSION
Seismic qualification is mandatory for all equipments before they are
installed in a Nuclear Facility.
ASME Sec III, is applicable for qualification based on the safety class of the
equipment.
FE Software provides a comprehensive assessment for qualification.
We have developed macros & scripts for load combination and qualification.
Successfully completed >45 projects on seismic qualification.
DAE entities & their EPCs: NPCIL, IGCAR, BARC-NRB and Punj Lloyd/
L&T
ITER, France through AMEC Nuclear, UK.
15. engineering your designswww.pro-sim.com 15