www.E-Inst.com
P: (215) 750-1212 F: (215) 750-1399
A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047
2017 Product Catalog
Built With Quality In Mind
Emiss
ions Analyzers Combustion Ana
lyzers
Ind
oor Air Quality Automotive Emiss
ions
E Instruments International
Built With Quality In Mind
The E Instruments organization is a privately held company originally incorporated in
2001 by experts with over 30 years of experience in design manufacturing and industrial
applications. The initial business mission was to provide high quality instrumentation
designed to measure the flue gas emissions from industrial applications.
After many years of successful growth and recognition in the international markets, the
company was incorporated as E Instruments International LLC with the expanded mission
to design, manufacture and market a complete range of innovative instrumentation
solutions encompassing portable Emissions, Exhaust, and Combustion Analyzers,
and Indoor Air Monitors especially designed for the industrial, HVAC, commercial,
automotive, and institutional markets worldwide.
E Instruments’ continued success is based on our commitment to:
With manufacturing facilities in the USA and Europe, our team continues to grow
and we are currently exporting to over 65 countries worldwide.
ABOUT US
1) Design instruments to meet our customer’s needs
2) Apply our expertise to monitoring unique and specialized applications
3) Deliver Analyzers and Monitors Built with Quality in Mind
4) Provide excellent Customer Support
Contents
HVAC Combustion Analyzers Page 4-19
Portable Emissions Analyzers Page 20-33
Indoor Air Quality Monitors Page 42-57
& Calibration Services
NONNNNNNNOOOOOOO
CH O2
CO2CCCCCOOOOOO22222222
SSSSSSS2H
CCCOOO
% RH%%%% RRRHHHH%%%% RRRRRHHHHH
NO2NNNNNNNNNNNOOOOOOOO22222222
SO2
O2
Quality Control, Customer Support
Qualified customer support & technical specialists will work with you and your team with any
product and application questions you may have on a timely manner. We appreciate that your
time is precious and that your analyzers/instruments are important tools for your business.
Our modern Calibration Laboratories provide high quality calibration services and certificates
using EPA protocol gases and NIST traceable calibration standards. Additional traceable
calibration services are offered at our ISO 17025 & ISO 9001 accredited laboratory.
Our Distribution network offers sales and technical product support in many
countries around the world.
E Instruments’ quality control premise encompasses the complete business process from
design, manufacturing, administration, customer support, and after sale Calibration & repair
Services. Our team of qualified professionals is fully committed to our basic philosophy of
“Built with Quality in Mind”, which applies to all products and services offered by our company.
Automotive Exhaust Gas Analyzers Page 34-41
Markets & Applications
‡ Boiler, Furnace, and Burner Manufacturers
‡ Residential, Commercial,& Light Industrial
‡ Condensing Boilers and Furnaces
‡ Boilers, Furnaces, and Heaters
‡ HVAC & Controls Wholesale
‡ HVAC Technical Schools
‡ Retail, Malls, Hotels
‡ Energy Auditing
‡ Weatherization
‡ Hospitals
‡ Schools
Built With Quality In Mind
HVAC
Product Line
Combustion Analyzers
4500
O2, CO, NO
NO2, SO2
7899
Gas Leak Detector
1500
O2, COO2, C900
O2, CO, NO,
CxHy
O2, C
C700
O2, CO
Built With Quality In Mind
‡ Gas & Diesel Engines
‡ Laboratory Analysis
‡ Gas Turbines
‡ Incinerators
‡ Furnaces
‡ Heaters
‡ Boilers
‡ Kilns
Applications
Relevant Markets
‡ Chemical & Industrial Processes
‡ Cement & Mineral Processing
‡ Natural Gas Compression
‡ Universities & Research
‡ Utilities & Power Plants
‡ Power Generation
‡ Petrochemical
‡ Heat Treating
‡ Biomass
‡ Marine
‡ Mining
Industrial
Product Line
Emissions Analyzers
1500
O2, COO
4500
O2, CO, NO
NO2, SO2,
CxHy
E8500 Plus
Up to 9 Gas Sensors
O2, CO, NO, NO2, SO2, H2S
NDIR: CO2, High CO, CxHy
PID: VOC
O
2,
6000
O2, CO, NO
NO2, SO2,
CxHy, H2S
(Max 4 Gas Sensors)
(4 or 5 Gas Sensors)
4 Gas Sensors)4 Gas
E9000
Up to 9 Gas Sensors
O2, CO, NO, NO2, SO2, H2S
NDIR: CO2, High CO, CxHy
Heated Sample Line
Built with Quality in MindFor Boiler & Burner Set-Up, Servicing, & Maintenance
Economical Residential Combustion Analyzer
Robust
Fast
Reliable
Accurate
CO
CO2
O2
Draft & Differential Pressure
Built-In Manometer
Ambient CO Monitor
Flue & Ambient Temp
CO Sensor with NOx Filter
Combustion Efficiency
PC Software w/ Auto Saving
Unbreakable Metal Connections
5 Tools-In-One
TRUE High-
Efficiency for
ALL Condensing Systems
TTTT
ffi i
Automatic,
EfEf
TRUE High
y f
d i S t
TTTTatic,
Calculations
Field ReplaceableFiFieldFie
Pre-Calibrated Sensors
Wireless Bluetooth™ PrinterWirreWire
Built with QuaMaintenance
ure
p
Ox Filter
iency
g
i ns
e
E Instruments International
P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
www.E-Inst.com
CO
CO˺
Tair
Tgas
Differential Temp
Pressure/Draft
Excess Air
Efficiency
Warranty
Electrochemical
Calculated
Pt100
Tc K
Calculated
Calculated
Calculated
Semiconductor
2 years: Analyzer + Sensors
0 - 8000 ppm
0 - 99.9%
-10 to 212°F
-10 to 1830°F
-10 to 1830°F
±0 - 80 inH˺0
0 - 850%
0 - 100%
1 ppm
0.1%
0.1°F
0.1°F
0.1°F
0.001 inH˺0
1%
0.1%
Parameter Sensor ResolutionRange Accuracy
O˺ Electrochemical 0 - 25% 0.1% ±0.2% vol
±8 ppm <400 ppm
±1°F
±1% rdg.
±2°F
Built with Quality in Mind
Ordering Information
Model No. Description
700 - A
700 - AP
Model 700 Kit = O˺, CO, CO˺, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air, 300 Internal Test
Memory, PC Software Included + New Auto Outdoor Air Temp. Saving for TRUE Efficiency Calculations
Model 700 Kit w/ Printer = O˺, CO, CO˺, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air,
300 Internal Test Memory, PC Software Included + Wireless Bluetooth™ Printer + New Auto Outdoor Air
Temp. Saving for TRUE Efficiency Calculations
E Instruments International
P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
www.E-Inst.com
˒ New Auto Outdoor Air Temp
˒ O˺, CO, CO˺
˒ Combustion Efficiency, Losses, &
Excess Air
˒ CO Air Free
˒ Draft & Differential Pressure
˒ Temperature Measurements
˒ 300 Test Internal Memory
˒ Bluetooth Connectivity
˒ Long Lasting Rechargeable Battery
& AC Charger
˒ Gas Sampling Probe & Hoses
˒ Water Trap with Filter Cartridge
˒ Operating Manual
˒ Calibration Certification
All Model 700 Kits Include:
˒ Magnetic Rubber Holster
˒ PC Software & USB Cable
˒ Vinyl Carrying Case
˒ ɟÞNjsĶsǣǣ DĶȖsǼŸŸǼÌ˗ ƻNjÞŘǼsNj
Optional Wireless
Bluetooth™ Printer
(No More Lining Up
Infrared Printers!)
NNNEEEWW!!!
Internal Memory &
PC Software Included
Pre-Calibrated
Field Replaceable
Sensors
10 Fuel / Oil Types
Including Bio-Heat 5%
Unbreakable Metal
Connections
Outdoor
Air Temp. & High
Efficiency
(Condensing Systems)
H˺ Compensated
w/ Built-In NOx Filter ±10 % rdg for >2000 ppm
±5% rdg up to 2000 ppm
O
Air Temp &
Automatic
mpppp. & Higggh
y
sing Systems)
Calculations
AA
Options:
The Latest in Combustion Analysis Technology
CO
CO2
O2
Field Replaceable SensorsFiFieFi
Robust
Fast
Reliable
Accurate
E Instruments International
P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
www.E-Inst.com
Built with Quality in Mind
Wireless Bluetooth™ Printer
N
o
w
W
ith WirelessBl
uetooth™ Printer
Economical Combustion & Emissions Analyzer
Upgradeable to NO/NOxUpgU
Draft & Differential Pressure
Built-In Manometer
Ambient CO Monitor
Flue & Ambient Temp
Upgradeable to NO/NOx
Combustion Efficiency
PC Software w/ Auto Saving
Unbreakable Metal Connections
TRUE High-
Efficiency for
ALL Condensing Systems
TTT
Effi i
Automatic,
E
TRUE High
y f
d i S t
TTTatic,
Calculations
5 Tools-In-One
NOx
d Replaceablieldie
eless Bluetooth™ PrinterWiWireWir
N
o
w
W
ith WirelessBl
uetooth™ Printer
mp
o NO/NOx
Efficiency
In-One
Built with Quality in Mind
Ordering Information
Model No. Description
900 - 2
900 - 3
900 - 3P
Base Kit = O˺, CO, CO˺, Upgradeable to NO/NOx, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air, 600 Internal Test Memory,
PC Software Included + New Auto Outdoor Air Temp. Saving for TRUE Efficiency Calculations
900 - 2P Base Kit w/ Printer = O˺, CO, CO˺, Upgradeable to NO/NOx, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air, 600 Internal Test
Memory, PC Software Included + Wireless Bluetooth™ Printer + New Auto Outdoor Air Temp. Saving for TRUE Efficiency Calculations
NOx Base Kit = O˺, CO, CO˺, NO/NOx Included, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air, 600 Internal Test Memory,
PC Software Included + New Auto Outdoor Air Temp. Saving for TRUE Efficiency Calculations
NOx Kit w/ Printer = O˺, CO, CO˺, NO/NOx Included, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air, 600 Internal Test Memory,
PC Software Included + Wireless Bluetooth™ Printer + New Auto Outdoor Air Temp. Saving for TRUE Efficiency Calculations
E Instruments International
P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
www.E-Inst.com
˒ New Auto Outdoor Air Temp
˒ O˺, CO, CO˺
˒ Upgradeable to NO/NOx
˒ Combustion Efficiency, Losses, &
Excess Air
˒ CO Air Free
˒ Draft & Differential Pressure
˒ Temperature Measurements
˒ 600 Test Internal Memory
˒ Bluetooth Connectivity
˒ Long Lasting Rechargeable Battery
& AC Charger
˒ Gas Sampling Probe & Hoses
˒ Water Trap with Filter Cartridge
˒ Magnetic Rubber Holster
˒ PC Software & USB Cable
˒ Operating Manual
˒ Calibration Certification
˒ Vinyl Carrying Case
˒ ŷƼǼÞŸŘ Ķ ɟÞNjsĶsǣǣ DĶȖsǼŸŸǼÌ˗ ƻNjÞŘǼsNj
All Model 900 Kits Include:
Optional Wireless
Bluetooth™ Printer
(No More Lining Up
Infrared Printers!)
NNEEWW!!!
Internal Memory &
PC Software Included
Pre-Calibrated
Field Replaceable
Sensors
10 Fuel / Oil Types
Including Bio-Heat 5%
Unbreakable Metal
Connections
Outdoor
Air Temp. & High
Efficiency
(Condensing Systems)
CO
CO˺
NO
NOx
Tair
Tgas
Differential Temp
Pressure/Draft
Excess Air
Efficiency
Warranty
Electrochemical
Electrochemical
Calculated
Calculated
Pt100
Tc K
Calculated
Calculated
Calculated
Semiconductor
2 years: Analyzer + Sensors
0 - 8000 ppm
0 - 99.9%
0 - 4000 ppm
0 - 5000 ppm
-10 to 212°F
-10 to 1830°F
-10 to 1830°F
±0 - 80 inH˺0
0 - 850%
0 - 100%
1 ppm
0.1%
1 ppm
1 ppm
0.1°F
0.1°F
0.1°F
0.001 inH˺0
1%
0.1%
Parameter Sensor ResolutionRange Accuracy
O˺ Electrochemical 0 - 25% 0.1% ±0.2% vol
±8 ppm <400 ppm
±5 ppm <100 ppm
±5% rdg up to 1000 ppm
±10% rdg for >4000 ppm
±1°F
±1% rdg.
±2°F
H˺ Compensated
w/ Built-In NOx Filter ±10 % rdg for >2000 ppm
±5% rdg up to 2000 ppm
O
Air Temp &
Automatic
mpppp. & Higggh
y
sing Systems)
Calculations
AA
The Latest in Combustion Analysis Technology
CO
CO˺
O2
Field Replaceable SensorsFiFieFie
Robust
Fast
Reliable
Accurate
E Instruments International
P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
www.E-Inst.com
Built with Quality in Mind
Wireless Bluetooth™ Printer
Combustion & Safety Analyzer
Measure CxHy Hydrocarbons for SafetyMeaM
Draft & Differential Pressure
Built-In Manometer
Ambient CO Monitor
Flue & Ambient Temp
Burner/Boiler Safety
Combustion Efficiency
PC Software w/ Auto Saving
Unbreakable Metal Connections
Ideal for Maintaining &
Troubleshooting Residential
Commercial Burners
5 Tools-In-One
CxHy
d Replaceablelde
eless Bluetooth™ PrinterWiWireWir
p
afety
Efficiency
n-One
CO
CO˺
Tair
Tgas
Differential Temp
Pressure/Draft
Excess Air
Efficiency
Warranty
Electrochemical
Calculated
Pt100
Tc K
Calculated
Calculated
Calculated
Semiconductor
2 years: Analyzer + Sensors
0 - 8000 ppm
0 - 99.9%
-10 to 212°F
-10 to 1830°F
-10 to 1830°F
±0 - 80 inH˺0
0 - 850%
0 - 100%
1 ppm
0.1%
0.1°F
0.1°F
0.1°F
0.001 inH˺0
1%
0.1%
Parameter Sensor ResolutionRange Accuracy
O˺ Electrochemical 0 - 25% 0.1% ±0.2% vol
±10 ppm <400 ppm
±1°F
±1% (-4.014 - 0.806 inH˺0)
±0.008 (-0.802 - 0.802 inH˺0)
±1% (0.806 - 0.292 inH˺0)
±2°F
Built with Quality in Mind
Ordering Information
Model No. Description
900 - C CxHy Base Kit = O˺, CO, CO˺, CxHy Included, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air, 600 Internal
Test Memory, PC Software Included + New Auto Outdoor Air Temp. Saving for TRUE Efficiency Calculations
900 - CP CxHy Kit w/ Printer = O˺, CO, CO˺, CxHy Included, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air,
600 Internal Test Memory, PC Software Included + Wireless Bluetooth™ Printer + New Auto Outdoor Air Temp. Saving
for TRUE Efficiency Calculations
E Instruments International
P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
www.E-Inst.com
Optional Wireless
Bluetooth™ Printer
NNEEWW!!
Pre-Calibrated
Field Replaceable
Sensors
10 Fuel / Oil Types
Including Bio-Heat 5%
Unbreakable Metal
Connections
Outdoor
Air Temp. & High
Efficiency
(Condensing Systems)
H˺ Compensated
w/ Built-In NOx Filter ±10 % rdg for >2000 ppm
±5% rdg up to 2000 ppm
O
Air Temp &
Automatic
mpppp. & Higggh
y
sing Systems)
Calculations
AA
CxHy (HC) Pellistor 0 - 5% 0.01% ±5% Full Scale
Troubleshoot
Burner Defects
Draft/Air Supply
Malfunction
Damaged or Clogged
Burner Tip
Residential & Commercial COMBUSTION ANALYZER
The Latest in Combustion Analysis Technology
CO
CO2
O2
BUILT-IN PrinterBUIIUI
Full COLOR Graphic DisplayFulFullFull
Field Replaceable SensorsFiFielFie
Robust
Fast
Reliable
Accurate
5 Tools-In-One
Built-In Manometer
Ambient CO Monitor
Flue & Ambient Temp
Draft & Differential Pressure
Combustion Efficiency
E Instruments International
P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
www.E-Inst.com
ial USTIOCOMBUS
LLT IN PrinterLTI
One
r
Temp
ential Pressure
Built with Quality in Mind
PC Software w/ Auto Saving
r
Unbreakable Metal Connections
, TRUE High-
Efficiency for
ALL Condensing Systems
EEffii iiE
Automatic TTRRUUE High
yy f
d i S t
,,,,attiicc
Calculations
ols-In-OOne
resse
E Instruments International
P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
www.E-Inst.com
Built with Quality in Mind
O˺
CO
CO˺
Tair
Tgas
Differential Temp.
Pressure/Draft
Excess Air
Efficiency
Warranty
Parameter
H˺ Compensated
w/ Built-In NOx Filter
Sensor
Electrochemical
Electrochemical
Calculated
Pt100
Tc K
Calculated
Semiconductor
Calculated
Calculated
Range Resolution Accuracy
0 - 25 %
0 - 8000 ppm
0 - 99.9%
-10 to 212 ̿F
-10 to 1830 ̿F
-10 to 1830 ̿F
±0 - 80 inH˺O
0 - 850%
0 - 100%
0.1 %
1 ppm
0.1 %
0.1 ̿F
0.1 ̿F
0.1 ̿F
0.001 inH˺O
1 %
0.1 %
±0.2 % vol
±8 ppm <400 ppm
±5 % rdg up to 2000 ppm
±10 % rdg for >2000 ppm
±1 ̿F
±2 ̿F
±1 % rdg.
2 years: Analyzer + Sensors
Ordering Information
Model No. Description
1500-1 Model 1500 Base Kit = Analyzer w/ O˺, CO, CO˺, Efficiency, Excess Air, Draft, Pressure, Temp, Rechargeable
Battery & AC Plug, 10’ Dual Hose, 12” Probe, Vinyl Case, Calibration Certificate, Operating Manual, Cheat
Sheet, Water Trap, Paper Roll, 2000 Internal Data Storage, PC Software, Bluetooth™ Connectivity,
Automatic Outdoor Air Temperature Saving for ALL 90%+ Systems & Condensing Systems for
TRUE Efficiency Calculations + Built-In Printer + New Android App Included
1500-Oil Standard 1500-1 Kit PLUS: Oil Smoke Pump, Smoke Filter Papers, and Comparison Chart
PC Software, Bluetooth,
& App Included
Large Color
Graphic Display
All Model 1500 Kits
Include:
Magnetic
Rubber Holster
Pre-Calibrated
Field Replaceable
Sensors
BUILT-IN PRINTER
(NON-Fading Paper)
Simple Menu
Interface
Full COLOR
Graphic Display
Unbreakable Metal
Connections
Outdoor
Air Temp. & High-
Efficiency
(Condensing Systems)
˒ New Android App
˒ New Auto Outdoor Air Temp.
˒ Built-In Printer
˒ Large Color Display
˒ O˺, CO, CO˺
˒ Combustion Efficiency, Losses,
Excess Air
˒ CO Air Free
˒ Draft & Differential Pressure
˒ Temperature Measurements
˒ 2000 Test Internal Memory
˒ Bluetooth Connectivity
˒ Long Lasting Rechargeable
Battery & AC Charger
˒ Gas Sampling Probe & Hose
˒ Water Trap with Filter
Cartridge
˒ Magnetic Rubber Holster
˒ PC Software & USB Cable
˒ Operating Manual
˒ Calibration Certificate
˒ Carrying Case
O
Air Temp &A
Automatic
mppp. & High-
y
sing S stems)
Calculations
Industrial Combustion Gas & Emissions Analyzer
CO
CO2
O2
Robust
Fast
Reliable
Accurate
Internal Memory (2000 Tests)
2 Channel Thermometer
CO Sensor w/ NOx Filter
Draft & Differential Pressure
E Instruments International
P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
www.E-Inst.com
is & Emi
re
Built with Quality in Mind
BUILT-IN PrinterBUILFull COLOR Graphic DisplayFull
Customizable Display Screen & Print-Out
Pre-Calibrated, Field Replaceable
Gas Sensors
Combustion Efficiency
Up To FOUR Gas Sensors
NO2
SO2
NO
NOx
CxHy
(HC)
Handheld Versatile Gas Analyzer for Emissions Monitoring of
Boiler, Engine, Furnace, and Other Combustion Applications
Dilution Pump For CO Auto-Range
Measurements Up To 10%
PC Software with Bluetooth
Total NOx Capable
NEW Sample Conditioning Unit For
Low NOx & Low SO2 Applications
Automatic Data Saving
N
SSam
ple Conditioning Unit
For Low
NOx & SO2
E Instruments International
P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
www.E-Inst.com
Built with Quality in Mind
Sample Conditioning Unit
For Low NOx & SO˺ Applications
Removes Moisture at the Probe For More
Accurate Low NOx & SO2 Measurements
O˺
CO
CO˺
Tair
Tgas
Pressure/Draft
Excess Air
Efficiency
Parameter
H˺ Compensated
w/ Built-In NOx Filter
Sensor
Electrochemical
Electrochemical
Calculated
Pt100
Tc K
Semiconductor
Calculated
Calculated
Range Resolution Accuracy
0 - 25 %
0 - 8000 ppm
0 - 99.9%
-10 to 212 ̿F
-4 to 2280 ̿F
±0 - 80 inH˺O
0 - 850%
0 - 100%
0.1 %
1 ppm
0.1 %
0.1 ̿F
0.1 ̿F
0.001 inH˺O
1 %
0.1 %
±0.2 % vol
±8 ppm (0 - 200ppm)
±5 % rdg (201 - 2000ppm)
±10 % rdg (2001 - 8000ppm)
±1 ̿F
±0.5 ̿C (-20 to 100 ̿C)
±1.0% rdg
CO DILUTED Electrochemical 0.8% - 10.00% 0.01% ±10% rdg
NO Electrochemical
NO˺ Electrochemical
Low NO and/or
Low NO˺
NOx Calculated
SO˺
Electrochemical
Electrochemical
0 - 5000 ppm
0 - 1000 ppm
0 - 100.0 ppm
0 - 5000 ppm
0 - 5000 ppm
1 ppm
1 ppm
0.1 ppm
1 ppm
1 ppm
±5 ppm (0 - 100 ppm)
±5% rdg (101 - 5000ppm)
±5 ppm (0 - 100 ppm)
±5% rdg (101 - 1000ppm)
±1.5 ppm (0.0 - 40.0ppm)
±5% rdg (40.1 - 100.0ppm)
±5 ppm (0 - 100ppm)
±5% rdg (101 - 5000ppm)
-20 to 1250 ̿C
-10 to 100 ̿C ±1 ̿C
̝˟ʳˤ̇ Nj_¶ ʹˠ˟ˠ ǼŸ ˠˡˤ˟ ̿C)
0.1 ̿C
0.1 ̿C
Ordering Information
Model No. Description
4500 with O˺, CO, NO/NOx, SO˺ Gas Sensors & CO Dilution Auto-Range to 50,000 ppm
4500 with O˺, CO, NO/NOx Gas Sensors Installed, Upgradeable to 4th Gas Sensor4500-3
4500 with O˺, CO, NO/NOx, NO˺ Gas Sensors & CO Dilution Auto-Range to 50,000 ppm4500-N
4500-S
Probes & Hoses
Standard: 12”, 300mm Probe,
1470̿F/800̿C max with
10’/3m Dual Hose
Long: 30”, 750mm Probe,
1470̿F/800̿C max with
10’/3m Dual Hose
Long & High Temp: 40”, 1m Probe,
2190̿F/1200̿C max, with
10’/3m Hose
Hose Extensions: 10’/3m Length
Available
All Model 4500 Kits Include:
˒ Built-In Printer
˒ Draft & Differential Pressure
˒ Temperature Measurements
˒ Calculation for CO˺, Efficiency
& Excess Air
˒ Rechargeable Batteries &
AC Charger
˒ Gas Sampling Probe & Hoses
˒ Water Trap with Filter Cartridge
˒ Magnetic Rubber Holster
˒ 2000 Test Internal Memory
˒ PC Software & USB Cable
˒ Bluetooth Module (Internal)
˒ Operating Manual
˒ Calibration Certificate
˒ ABS Hard Plastic Carrying Case
4500 with O˺, CO, NO/NOx, CxHy (HC) Gas Sensors & CO Dilution Auto-Range to 50,000 ppm4500-C
CxHy (HC) Pellistor 0 - 5% 0.01% ±5% Full Scale
Bulletin:E4500.3Ed.01/2017Information&designsubjecttochangeatmanufacture’sdiscretion
Low SO˺ Electrochemical 0 - 100.0 ppm 0.1 ppm ±1.5 ppm (0.0 - 40.0ppm)
±5% rdg (40.1 - 100.0ppm)
4500-NLow
4500-SLow
4500 with O˺, CO, Low NO/NOx, Low NO˺ Gas Sensors & CO Dilution Auto-Range to 50,000 ppm
4500 with O˺, CO, NO/NOx, Low SO˺ Gas Sensors & CO Dilution Auto-Range to 50,000 ppm
High Temperature Probe
& Sintered Filter Available
P
eeeeree ed FFilter Avvailableinte& Sintered FFilter Av
Six Gas Industrial Emissions Analyzer
CO
CO2
O2
Robust
Fast
Reliable
Accurate
Internal Memory (2000 Tests)
Low NOx & Low SO˺ Capable
CO Sensor w/ NOx Filter
Draft & Differential Pressure
E Instruments International
P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
www.E-Inst.com
Capable
r
ure
Built with Quality in Mind
BUILT-IN PrinterBUILFull COLOR Graphic DisplayFull
Customizable Display Screen & Print-Out
Pre-Calibrated, Field Replaceable
Gas Sensors
Combustion Efficiency
Up To SIX Gas Sensors
Hand-Held Versatile Gas Analyzer for Emissions Monitoring of
Boiler, Engine, Furnace, and Other Combustion Applications
Dilution Pump For CO Auto-Range
Measurements Up To 10%
PC Software with Bluetooth
Total NOx Capable
NEW Sample Conditioning Unit For
Low NOx & Low SO˺ Applications
Automatic Data Saving
Sam
ple Conditioning Unit
For Low
NOx & SO2
NO˺
SO˺
NO
NOx
CxHy
(HC)
H˺Ǣ
E Instruments International
P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
www.E-Inst.com
Built with Quality in Mind
Sample Conditioning Unit
For Low NOx & SO˺ Applications
Removes Moisture at the Probe For More
Accurate Low NOx & SO2 Measurements
O˺
CO
CO˺
Tair
Tgas
Pressure/Draft
Excess Air
Efficiency
Parameter
H˺ Compensated
w/ Built-In NOx Filter
Sensor
Electrochemical
Electrochemical
Calculated
Pt100
Tc K
Semiconductor
Calculated
Calculated
Range Resolution Accuracy
0 - 25 %
0 - 8000 ppm
0 - 99.9%
-10 to 212 ̿F
-4 to 2280 ̿F
±0 - 80 inH˺O
0 - 850%
0 - 100%
0.1 %
1 ppm
0.1 %
0.1 ̿F
0.1 ̿F
0.001 inH˺O
1 %
0.1 %
±0.2 % vol
±8 ppm (0 - 200ppm)
±5 % rdg (201 - 2000ppm)
±10 % rdg (2001 - 8000ppm)
±1 ̿F
±0.5 ̿C (-20 to 100 ̿C)
±1.0% rdg
CO DILUTED Electrochemical 0.8% - 10.00% 0.01% ±10% rdg
NO Electrochemical
NO˺ Electrochemical
Low NO and/or
Low NO˺
NOx Calculated
SO˺
Electrochemical
Electrochemical
0 - 5000 ppm
0 - 1000 ppm
0 - 100.0 ppm
0 - 5000 ppm
0 - 5000 ppm
1 ppm
1 ppm
0.1 ppm
1 ppm
1 ppm
±5 ppm (0 - 100 ppm)
±5% rdg (101 - 5000ppm)
±5 ppm (0 - 100 ppm)
±5% rdg (101 - 1000ppm)
±1.5 ppm (0.0 - 40.0ppm)
±5% rdg (40.1 - 100.0ppm)
±5 ppm (0 - 100ppm)
±5% rdg (101 - 5000ppm)
-20 to 1250 ̿C
-10 to 100 ̿C ±1 ̿C
̝˟ʳˤ̇ Nj_¶ ʹˠ˟ˠ ǼŸ ˠˡˤ˟ ̿C)
0.1 ̿C
0.1 ̿C
Ordering Information
Model No. Description
E6000 with O˺, CO, NO, SO˺, H˺S Gas Sensors Installed, Upgradeable to 6th Gas Sensor*
E6000 with O˺, CO, NO, NO˺ , SO˺ Gas Sensors Installed, Upgradeable to 6th Gas Sensor*E6000-5DS
E6000 with O˺, CO, NO, NO˺, CxHy(HC) Gas Sensors Installed, Upgradeable to 6th Gas Sensor*E6000-5DC
E6000-5SH
Probes & Hoses
Standard: 12”, 300mm Probe,
1470̿F/800̿C max with
10’/3m Dual Hose
Long: 30”, 750mm Probe,
1470̿F/800̿C max with
10’/3m Dual Hose
Long & High Temp: 40”, 1m Probe,
2190̿F/1200̿C max, with
10’/3m Hose
Hose Extensions: 10’/3m Length
Available
All E6000 Kits Include:
˒ Built-In Printer
˒ CO Dilution Auto-Range to 10%
˒ Draft & Differential Pressure
˒ Temperature Measurements
˒ Calculation for CO˺, Efficiency
& Excess Air
˒ Rechargeable Batteries &
AC Charger
˒ Gas Sampling Probe & Hoses
˒ Water Trap with Filter Cartridge
˒ Magnetic Rubber Holster
˒ 2000 Test Internal Memory
˒ PC Software & USB Cable
˒ Bluetooth Module (Internal)
˒ Operating Manual
˒ Calibration Certificate
˒ ABS Hard Plastic Carrying Case
˒ Android Smart Phone App
CxHy (HC) Pellistor 0 - 5% 0.01% ±5% Full Scale
Bulletin:E6000.2Ed.01/2017Information&designsubjecttochangeatmanufacture’sdiscretion
Low SO˺ Electrochemical 0 - 100.0 ppm 0.1 ppm ±1.5 ppm (0.0 - 40.0ppm)
±5% rdg (40.1 - 100.0ppm)
E6000-5SC E6000 with O˺, CO, NO, SO˺, CxHy(HC) Gas Sensors Installed, Upgradeable to 6th Gas Sensor*
High Temperature Probe
& Sintered Filter Availabled FFilter Aveeeereee ed vailable& Sinteered FFilter Avere
*All Configurations Available With Low NO, Low NO˺, and/or Low SO˺ Sensors
H˺S Electrochemical 0 - 500 ppm 0.1 ppm ±5 ppm (0.0 - 125.0ppm)
±4% rdg (125.1 - 500.0ppm)
E6000-6DSH
E6000-6DSC
E6000 with O˺, CO, NO, NO˺, SO˺, H˺S Gas Sensors Installed*
E6000 with O˺, CO, NO, NO˺, SO˺, CxHy(HC) Gas Sensors Installed*
Portable Industrial Flue Gas & Emissions Analyzer
Complete Portable Emissions Analyzer with up to Nine Gas Sensors
for Boiler, Engine, Furnace, and other Combustion Applications
CO
O˺
E Instruments International
P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047
www.E-Inst.com
Built with Quality in Mind
NO
E8500 PLUS
Built-In Thermoelectric Chiller
Up to 9 Total Gas Sensors
MADE IN USA
CO Dilution Auto-Range
Automatic Condensate Drain
Long Life Rechargeable Battery
Upgraded Memory (2000 Tests)
True NOx & Low NOx Measurements
High Accuracy NDIR Sensors
NO˺
SO˺
H˺S
VOC
CO˺
NEW Display Screen & Keypad
NEW Software with Automatic Data Logging
Direct CO˺ Measurement to 50%
y
2000 Tests)
ents
creen & Keypad
nt to 50%
CxHy(HC)
NEW Display Screen & Keypad Design
with Easy Filter Replacement
NEW
REAL-TIME Software Package
with Automatic Data Logging
REA
NEW PID VOC Sensor OptionNEW
(NDIR)
True SO˺ & Low SO˺ Measurements
Sample Conditionniinng UUnnit
For Looww NNOOx & SO2
Backlit Display with Zoom Function
E Instruments International
P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047
www.E-Inst.com
Built with Quality in Mind
E8500 PLUS
The updated “EGAS” software package includes the ability
to save & graph data in real-time in the field with a laptop or in
a laboratory with a PC. It also allows the user to automatically
log data for an exact number of tests for a specified time
period. Communications between the E8500 PLUS and a
computer are established either by wireless Bluetooth
communications or USB cable. A Bluetooth wireless adapter
for a computer comes standard with each E8500 PLUS gas
analyzer. Data from the “EGAS” software can be exported to
other spreadsheet programs for more user flexibility to create
detailed emissions reports.
Real-Time Software with Data Logging
EGAS Software
The internal thermoelectric chiller efficiently
and quickly removes the water vapor from
the flue gas sample to prevent combustion
gases from bubbling from the gas phase into
the condensate. The built-in condensate drain
pump automatically pumps the accumulated
water out through the bottom of the unit
for greater convenience.
Built-In Thermoelectric Chiller
with Auto Condensate Drain
40”(1m) & 60”(1.5m)
High Temperature Probeshh Temperature Prob
40”(1m) & 600”(1 5m)
Sintered Filter
E Instruments International
P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047
www.E-Inst.com
Built with Quality in Mind
ϴϱϬϬ Wh^ ^ƉĞĐŝĮĐĂƟŽŶƐ
The E8500 PLUS has a
newly designed user
interface that includes an
easily accessible filter
compartment for quick and
simple inspection 
replacement of filters in
the field.
Easy Filter Replacement
The E8500 PLUS can have
a maximum of nine total
gas sensors; up to six
electrochemical type
sensors, up to three NDIR
type sensors, and an
optional PID sensor for
measuring VOC.
Gas Sensors
An internal pressure sensor
allows the analyzer to
measure both pressure and
stack draft. With two
pressure inputs, differential
pressure can also be
measured. Gas velocity
can be measured using the
differential pressure and an
optional Pitot tube.
Draft, Pressure,  Velocity
Parameter Sensor Range Res. Accuracy
O
CO
CO
NO
NO
Pressure/Draft
Excess Air
Gas Velocity
Efficiency
2
x
ppm=±4%
up to 5000 ppm=±4%
1.00 - infinity
Electrochemical up to 2000 ppm=±4%
2000 ppm=±10%
NDIR
Electrochemical
up to 5000
up to 1000 ppm=±4%
up to 500 ppm=±4%
14.0 - 212.0°F
32.0 - 1830°F
32.0 - 1830°F
Calculated
Calculated
Calculated
Auto Range
CO
NO
Low NO
Low NO
SO
CO
CO
C H
H S
VOC
Tair
Tgas
2
2
2
2
2
x y
2
'T
0 - 8000 ppm 1 ppm
300 ppm=±8 ppm
0.01% ±0.1% vol0 - 25%Electrochemical
±10% rdg.1 ppm0 - 20,000 ppmElectrochemical
0 - 15.00% 0.01% ±3% rdg.
0 - 5000 ppm 1 ppm
1 ppm
125 ppm=±5 ppm
Electrochemical 0 - 1000 ppm
125 ppm=±5 ppm
up to 100.0 ppm=±4%
0 - 100.0 ppm 0.1 ppmElectrochemical
50.0 ppm=±1.5 ppm
Calculated 0 - 5000 ppm 1 ppm
0 - 5000 ppmElectrochemical
125 ppm=±5 ppm
1 ppm
Calculated 0 - 99.9% 0.1%
0 - 50.0%
0 - 3.00%
0.1%
0.01% ±3% rdg. + 0.01%
±3% rdg.  20%
NDIR
NDIR
Electrochemical 0 - 500 ppm 1 ppm 125 ppm=±5 ppm
PID 0 - 200 ppm 1 ppm ±10 % rdg. + 1 ppm
Calculated
Pt100
-10 - 99.9°C 1°C
1°F
±2°C
±3°F
Tc K 0 - 999.9°C 0.1°C ±3°C
0.1°F ±5°F
0 - 999.9°C
1°F
1°C
Bridge ± 40.0 in H O 0.1 in H O ±1% rdg.
0.01
0 - 99.9 m/s
0 - 330 ft/s
0.1 m/s
0.1 ft/s
1 - 99.9% 0.1%
2 2
0 - 100.0 ppm 0.1 ppmElectrochemicalLow SO
0 - 100.0 ppm 0.1 ppmElectrochemical
2
up to 100.0 ppm=±4%
50.0 ppm=±1.5 ppm
up to 100.0 ppm=±4%
50.0 ppm=±1.5 ppm
The Sample Conditioning Unit
is mounted directly at the
sampling probe exit, where
excess moisture rapidly
condenses and separates
from the gas sample. This
minimizes contact of the gases
with moisture, which could
potentially affect NOx and
SO2 measurements.
Sample Conditioning Unit
±5% rdg.  20%
E Instruments International
P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047
www.E-Inst.com
Built with Quality in Mind
E8500 PLUS
E8500 PLUS Ordering Code
Part # 8500P - Table A - Table B - Table C
Table C - Sampling Probes and Hoses
12 12” (300mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose
30
40
60
30” (750mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose
40” (1m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for
High Temperature Combustion Applications
60” (1.5m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for
High Temperature Combustion Applications
Table B - NDIR (non-dispersive infrared) Sensors
ABC CO Sensor (0 - 50 %), CxHy Sensor (0 - 3 %), High CO Sensor (0 - 15 %)2 and
0 No NDIR sensors
Standard E8500 PLUS Configuration (E8500P-OCN-0-12) Includes:
- O2, CO, and NO Gas Sensors
- Thermoelectric Chiller with Automatic Condensate Drain Pump
- Rechargeable Battery Pack
- 110-240VAC/50-60Hz Battery Charger
- 12”/300mm Probe with 10’/3m Dual Hose
- Stack Gas  Air Temperature Measurements
- Draft  Differential Pressure Measurements
- Calculated Values for Efficiency, Excess Air,  CO %
- Internal Memory (2,000 Tests)
- Real-Time Software Package with Bluetooth Module
- Wireless Bluetooth Communications
- Protective Carrying Case
- Calibration Certificate
- Operations Manual
2
Weight: 11 lbs. (5 kg) Dimensions: 10x6x9.5” (26x15x24 cm)
mp
Bulletin:E8500PLUS.2Ed.01/2017Informationdesignsubjecttochangeatthemanufacturer’sdiscretion
Table A - Electrochemical Sensors
O
C
N
D
S
H
O Sensor (0 - 25 %)
CO Sensor (0 - 8000 ppm) with Dilution Auto-Range up to 20,000 ppm
NO Sensor (0 - 5000 ppm)
NO Sensor (0 - 1000 ppm)
SO Sensor (0 - 5000 ppm)
H S Sensor (0 - 500 ppm)
2
2
2
2
V VOC Sensor (0 - 200 ppm)**
*H S  VOC sensors cannot concurrently be installed on one E8500 PLUS2
**Must include NDIR sensor option to include VOC sensor
Portable Industrial Flue Gas  Emissions Analyzer
Portable Emissions Analyzer with Temperature Controlled NOx Measurement
for Boiler, Engine, Furnace, and other Combustion Applications
E Instruments International
P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047
www.E-Inst.com
Built with Quality in Mind
E8500 Cooled NOx
Built-In Thermoelectric Cooler
for NO Sensor
Up to 9 Total Gas Sensors
MADE IN USA
CO Dilution Auto-Range
Long Life Rechargeable Battery
Upgraded Memory (2000 Tests)
True NOx  Low NOx Measurements
NEW Display Screen  Keypad
NEW Software with Automatic Data Logging
Direct CO˺ Measurement to 50%
USAMADE IN UUS
NEW Cooled NO Sensor to Optimize
Accuracy of NOx Measurements
NEW
A
Displays  Records the Temperature
at the Cooled NO Sensor
DispDisp
CO
O˺
NO˺
SO˺
H˺S
VOC
CxHy
CO˺(NDIR)
NEW PID VOC Sensor Option
NOx
NO(Cooled)
E Instruments International
P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047
www.E-Inst.com
Built with Quality in Mind
E8500 Cooled NOx
The updated “EGAS” software package includes the ability
to save  graph data in real-time in the field with a laptop or in
a laboratory with a PC. It also allows the user to automatically
log data for an exact number of tests for a specified time
period. Communications between the E8500 Cooled NOx and a
computer are established either by wireless Bluetooth
communications or USB cable. A Bluetooth wireless adapter
for a computer comes standard with each E8500 Cooled NOx
gas analyzer. Data from the “EGAS” software can be exported
to other spreadsheet programs for more user flexibility to
create detailed emissions reports.
Real-Time Software with Data Logging
EGAS Software
The accuracy of the gas sensor for NO, the primary
component of NOx, can be compromised when
exposed to ambient temperatures above 86°F (30°C)
and significantly more so above 104°F (40°C).
To help prevent this temperature effect on the
NO sensor, the E8500 Cooled NOx keeps the NO
sensor cooled with an internal cooling system.
The analyzer measures, displays,  records the NO
sensor temperature to make it easier to comply with
US EPA conditional test methods such as CTM-030.
Cooled NO Sensor for Optimal Accuracy
Sintered Filter
40”(1m)  60”(1.5m)
High Temperature Probes
E Instruments International
P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047
www.E-Inst.com
Built with Quality in Mind
ϴϱϬϬ ŽŽůĞĚ EKdž ^ƉĞĐŝĮĐĂƟŽŶƐ
The E8500 Cooled NOx
has a newly designed
user interface that includes
an easily accessible filter
compartment for quick and
easy inspection  replacement
of filters in the field.
Easy Filter Replacement
The E8500 Cooled NOx can
have a maximum of nine
total gas sensors; up to six
electrochemical type sensors,
up to three NDIR type sensors,
and an optional PID sensor
for measuring VOC.
Gas Sensors
An internal pressure sensor
allows the analyzer to
measure both pressure and
stack draft. With two
pressure inputs, differential
pressure can also be
measured. Gas velocity
can be measured using the
differential pressure and an
optional Pitot tube.
Draft, Pressure,  Velocity
Parameter Sensor Range Res. Accuracy
O
CO
CO
NO
NO
Pressure/Draft
Excess Air
Gas Velocity
Efficiency
2
x
ppm=±4%
up to 5000 ppm=±4%
1.00 - infinity
Electrochemical up to 2000 ppm=±4%
2000 ppm=±10%
NDIR
Electrochemical
up to 5000
up to 1000 ppm=±4%
up to 500 ppm=±4%
14.0 - 212.0°F
32.0 - 1830°F
32.0 - 1830°F
Calculated
Calculated
Calculated
Auto Range
CO
NO
Low NO
Low NO
SO
CO
CO
C H
H S
VOC
Tair
Tgas
2
2
2
2
2
x y
2
'T
0 - 8000 ppm 1 ppm
300 ppm=±8 ppm
0.01% ±0.1% vol0 - 25%Electrochemical
±10% rdg.1 ppm0 - 20,000 ppmElectrochemical
0 - 15.00% 0.01% ±3% rdg.
0 - 5000 ppm 1 ppm
1 ppm
125 ppm=±5 ppm
Electrochemical 0 - 1000 ppm
125 ppm=±5 ppm
up to 100.0 ppm=±4%
0 - 100.0 ppm 0.1 ppmElectrochemical
50.0 ppm=±1.5 ppm
Calculated 0 - 5000 ppm 1 ppm
0 - 5000 ppmElectrochemical
125 ppm=±5 ppm
1 ppm
Calculated 0 - 99.9% 0.1%
0 - 50.0%
0 - 3.00%
0.1%
0.01% ±3% rdg. + 0.01%
±3% rdg.  20%
NDIR
NDIR
Electrochemical 0 - 500 ppm 1 ppm 125 ppm=±5 ppm
PID 0 - 200 ppm 1 ppm ±10 % rdg. + 1 ppm
Calculated
Pt100
-10 - 99.9°C 1°C
1°F
±2°C
±3°F
Tc K 0 - 999.9°C 0.1°C ±3°C
0.1°F ±5°F
0 - 999.9°C
1°F
1°C
Bridge ± 40.0 in H O 0.1 in H O ±1% rdg.
0.01
0 - 99.9 m/s
0 - 330 ft/s
0.1 m/s
0.1 ft/s
1 - 99.9% 0.1%
2 2
0 - 100.0 ppm 0.1 ppmElectrochemicalLow SO
0 - 100.0 ppm 0.1 ppmElectrochemical
2
up to 100.0 ppm=±4%
50.0 ppm=±1.5 ppm
up to 100.0 ppm=±4%
50.0 ppm=±1.5 ppm
The Sample Conditioning Unit
is mounted directly at the
sampling probe exit, where
excess moisture rapidly
condenses and separates
from the gas sample. This
minimizes contact of the gases
with moisture, which could
potentially affect NOx and
SO2 measurements.
Sample Conditioning Unit
±5% rdg.  20%
E Instruments International
P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047
www.E-Inst.com
Built with Quality in Mind
E8500 Cooled NOx
E8500 Cooled NOx Ordering Code
Part # 8500CN - Table A - Table B - Table C
Table C - Sampling Probes and Hoses
12 12” (300mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose
30
40
60
30” (750mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose
40” (1m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for
High Temperature Combustion Applications
60” (1.5m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for
High Temperature Combustion Applications
Table B - NDIR (non-dispersive infrared) Sensors
ABC CO Sensor (0 - 50 %), CxHy Sensor (0 - 3 %), High CO Sensor (0 - 15 %)2 and
0 No NDIR sensors
Standard E8500 Cooled NOx Configuration (E8500CN-OCN-0-12) Includes:
-
-
- Rechargeable Battery Pack
- 110-240VAC/50-60Hz Battery Charger
- 12”/300mm Probe with 10’/3m Dual Hose
- Stack Gas  Air Temperature Measurements
- Draft  Differential Pressure Measurements
- Calculated Values for Efficiency, Excess Air,  CO %
- Internal Memory (2,000 Tests)
- Real-Time Software Package with Bluetooth Module
- Wireless Bluetooth Communications
- Protective Carrying Case
- Calibration Certificate
-
2
Weight: 11 lbs. (5 kg) Dimensions: 10x6x9.5” (26x15x24 cm)
T
Bulletin:E8500CooledNOx.1Ed.03/2017Informationdesignsubjecttochangeatthemanufacturer’sdiscretion
Table A - Electrochemical Sensors
O
C
N
D
S
H
O Sensor (0 - 25 %)
CO Sensor (0 - 8000 ppm) with Dilution Auto-Range up to 20,000 ppm
NO Sensor (0 - 5000 ppm)
NO Sensor (0 - 1000 ppm)
SO Sensor (0 - 5000 ppm)
H S Sensor (0 - 500 ppm)
2
2
2
2
V VOC Sensor (0 - 200 ppm)**
*H S  VOC sensors cannot concurrently be installed on one E8500 Cooled NOx2
**Must include NDIR sensor option to include VOC sensor
-
-
NL Low NO Sensor (0 - 100.0 ppm)
DL Low NO Sensor (0 - 100.0 ppm)2
- NO Sensor Temperature Measurement
Operations Manual
External Water Trap with Filter
Thermoelectric Cooler for NO Sensor
O2, CO, and NO Gas Sensors
Sample Conditioning Unit
Portable Industrial Flue Gas  Emissions Analyzer
Transportable Emissions Analyzer for Boiler, Engine,
Furnace, Kiln, and other Combustion Applications
CO
O˺
E Instruments International
P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047
www.E-Inst.com
Built with Quality in Mind
NO
E9000
Built-In Thermoelectric Chiller
Up to 9 Total Gas Sensors
CO Dilution Auto-Range
Automatic Condensate Drain
Pre-Calibrated Gas Sensors
Upgraded Memory (16,000 Tests)
True NOx  Low NOx Measurements
High Accuracy NDIR Sensors
Including CO˺ Sensor to 50%
NO˺
SO˺
H˺S
Low
NOx
CO˺
Color Graphic Display
Software with Automatic Data Logging
Built-In Printer
CxHy(HC)
Heated Probe Head  Sample HoseHea
Software Package with Automatic
Data Logging
Soft
(NDIR)
Android App to Monitor  Save Data
lt-In Thermoelectric Chiller
ge
tic Condensate Drain
rs
emory (16,000 Tests)
ments
s
%
isplay
Software
US EPA CTM-030  CTM-034 Compliant
Customize to Meet Your Em
issio
ns
Monitoring Requirem
ents
Heavy Duty Case
E Instruments International
P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047
www.E-Inst.com
Built with Quality in Mind
E9000 Specifications
Heated Sample Hose  Probe Head
The E9000 has an optional heated probe head and flexible heated sample line. This feature maintains the sample
gas at a temperature higher than the dew point to prevent condensation from occurring before the stack gas
reaches the internal thermoelectric chiller. The water vapor condenses very rapidly at the chiller so the gases do
not have ample opportunity time to dissolve into the condensate. This sample conditioning system maintains the
integrity of the gas composition especially for the most water soluble gases such as NO˺ and SO˺.
The large multi-color graphic display screen includes a zoom
function. The capacitive touch sensing keypad guides the
operator through the user friendly menus on the display screen.
The measured  calculated parameters on the display screen
can be fully customized as the operator requires.
The internal printer is included with each E9000 and prints on a
special non-fading polymer paper so it can still be easily read
even when exposed to water, heat, or light. As with the display
screen, the parameters on the print-out can be customized by
each operator.
Each E9000 includes an internal high efficiency Peltier
thermoelectric chiller with a built-in condensate drain
pump that automatically pumps the accumulated water
out through the bottom of the unit for greater
convenience. Along with the optional heated sample
hose  probe head, this sample conditioning system
allows for longer test periods while maximizing the
integrity and composition of the sampled stack gas so
the gases measured by the analyzer are representative
of the actual stack/flue gases.
Superior Sample Conditioning for
Semi-Continuous Use
Display Screen  Keypad
Built-In Printer
E Instruments International
P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047
www.E-Inst.com
Built with Quality in Mind
E9000 Specifications
Parameter Sensor Range Res. Accuracy
O
CO
CO
NO
NO
2
x
ppm=±4%
up to 5000 ppm=±4%
Electrochemical up to 2000 ppm=±4%
2000 ppm=±10%
NDIR
Electrochemical
up to 5000
up to 1000 ppm=±4%
up to 500 ppm=±4%
Auto Range
CO
NO
Low NO
Low NO
SO
CO
CO
C H
H S
2
2
2
2
2
x y
2
0 - 8000 ppm 1 ppm
200 ppm=±5 ppm
0.1% ±0.1% vol0 - 25%Electrochemical
±10% rdg.0.01%0 - 10.00%Electrochemical
0 - 15.00% 0.01% ±3% rdg.
0 - 5000 ppm 1 ppm
1 ppm
125 ppm=±5 ppm
Electrochemical 0 - 1000 ppm
125 ppm=±5 ppm
up to 100.0 ppm=±4%
0 - 100.0 ppm 0.1 ppmElectrochemical
50.0 ppm=±1.5 ppm
Calculated 0 - 5000 ppm 1 ppm
0 - 5000 ppmElectrochemical
125 ppm=±5 ppm
1 ppm
Calculated 0 - 99.9% 0.1%
0 - 50.0%
0 - 50,000 ppm
0.1%
1 ppm
NDIR
NDIR
Electrochemical 0 - 500 ppm 0.1 ppm 125 ppm=±5 ppm
Pellistor 0 - 5.00% 0.01% ±5 % Full Scale
0 - 100.0 ppm 0.1 ppmElectrochemicalLow SO
0 - 100.0 ppm 0.1 ppmElectrochemical
2
up to 100.0 ppm=±4%
50.0 ppm=±1.5 ppm
up to 100.0 ppm=±4%
50.0 ppm=±1.5 ppm
C Hx y
up to 50,000 ppm=±2%
1000 ppm=±50 ppm
up to 50%=±5% rdg.
8%=±3% rdg.
E Instruments International
P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047
www.E-Inst.com
Built with Quality in Mind
E9000
Table C - Sampling Probes and Hoses
12 12” (300mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose
30
40
60
30” (750mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose
40” (1m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for
High Temperature Combustion Applications
60” (1.5m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for
High Temperature Combustion Applications
Table B - NDIR (non-dispersive infrared) Sensors
IR CO Sensor (0 - 50 %), CxHy Sensor (0 - 5 %), High CO Sensor (0 - 15 %)2 and
0 No NDIR sensors
Standard E9000 Configuration (E9000-OCN-0-12) Includes:
- O2, CO, and NO Gas Sensors, Upgradeable to 9 Gas Sensors Total
- Thermoelectric Chiller with Automatic Condensate Drain Pump
- Rechargeable Battery Pack
- 110-240VAC/50-60Hz Battery Charger
- 12”/300mm Probe with 10’/3m Dual Hose
- Stack Gas  Air Temperature Measurements
- Draft  Differential Pressure Measurements
- Calculated Values for Efficiency, Excess Air,  CO %
- Internal Memory (16,000 Tests)
- Software Package with USB  Bluetooth Interface
- Wireless Bluetooth Communications
- Heavy Duty Aluminum Carrying Case
- Calibration Certificate
- Operations Manual
2
Weight: 29 lbs. (13 kg) Dimensions: 20x14x8” (50x36x20 cm)
-12) Includeses:
Sensors Totalal
Pump
Bulletin:E9000.1Ed.6/2016Informationdesignsubjecttochangeatthemanufacturer’sdiscretion
E9000 Ordering Code
Part # 9000 - Table A - Table B - Table C
Table A - Electrochemical Sensors (Maximum of Six)
O
C
N
D
S
H
O Sensor (0 - 25 %)
CO Sensor (0 - 8000 ppm) with Dilution Auto-Range up to 10%
NO Sensor (0 - 5000 ppm)
NO Sensor (0 - 1000 ppm)
SO Sensor (0 - 5000 ppm)
H S Sensor (0 - 500 ppm)
2
2
2
2
NL Low NO Sensor (0 - 100.0 ppm)
DL Low NO Sensor (0 - 100.0 ppm)
SL Low SO Sensor (0 - 100.0 ppm)2
2
12” (300mm) Probe, 1470°F (800°C) max, with 10’ (3m) Heated
Sample Hose  Probe Head
12H
40” (1m) Probe, 2190°F (1200°C) max, with 10’ (3m) Heated Sample
Hose  Probe Head
40H
SINT1 Sintered Filter with Half Shield for Probe Tip
( ) p
Application Notes
Emissions Monitoring
E Instruments is Proud to Offer A Wide Variety of
In-Depth Application Notes to its Customers
Such As:
MARPOL ANNEX VI Compliance Using a Portable
Emissions Analyzer
Application Note # IA-14-0701
Flexibility  Versatility of a Portable Emissions AnalyzerApplication Note # IA-13-0501
Mining
Using Portable Emissions Analyzers for Optimizing the
Performance of a Cogeneration Plant
Application Note # IA-13-0801
Cogeneration
Forklifts
Marine
Power
Generation
Engines
Industrial
Boilers
For a Complete List of Our Application Notes
Please Visit Our Website at
www.E-Inst.com
Refineries
Cement
Incinerators
Application Notes
Combustion Analysis
E Instruments is Proud to Offer A Wide Variety of
In-Depth Application Notes to its Customers
Such As:
Why Use NOx Filters on CO Sensors?Application Note # HV-16-0915
The Importance of Combustible Gas Leak DetectionApplication Note # HV-13-0516
Boilers
Measuring Combustion Efficiency on Atmospheric
Boilers  Furnaces
Application Note # HV-13-0717
Technical
Schools
Burners
For a Complete List of Our Application Notes
Please Visit Our Website at
www.E-Inst.com
Furnaces
Heaters
Weatherization
Research 
Development
Energy
Auditing
Controls
Building
Inspection
Facilities
Gas Sampling Probes  Accessories
12(300mm) Standard Probe (gas  draft), 1470F(800C) max, with 10'(3m) dual hose
30(750mm) Probe (gas  draft), 1470F(800C) max, with 10'(3m) dual hose
Sintered Filter with Half-Shield for End of Probe (compatible with 40  60 Probes only)
for High Dust, Particle,  Ash Applications
36 (900mm) Pitot Tube for Measurements  Calculations of:
Standard Probes
Sintered Filter
Pitot Tube
˒ Stack/Flue Gas Velocity
˒ Coal Fired Boilers
˒ Cement Kilns
˒ Volumetric Flow Rate
˒ Mass Emissions
˒ Steel Furnaces
˒ Incinerators
˒ Boilers
˒ Burners
˒ Heaters
˒ Engines
Applications:
Applications:
40 (1m) Probe, 2190F (1200C) max, with 10' (3m) Hose
60 (1.5m) Probe, 2190F (1200C) max, with 10' (3m) Hose
Longer  High Temperature Probes
˒ Cement
˒ Power Plants
obes
˒ Steel
˒ Glass
Applications:
* Customized Probes available up to 100” (2.5m) in length available upon request
Sample Conditioning Unit
˒ High Moisture Flue Gases
˒ ĵŸɠ ŗŷɮ ˓ ĵŸɠ Ǣŷ˺
Measurements
Applications:
Removes moisture at probe handle
to maintain the integrity of the
sampled flue gas.
Available with all gas analyzers.
Built With Quality In Mind
‡ Automobiles
‡ Forklifts
‡ Trucks
‡ Buses
‡ Burnishers
‡ Loaders
‡ Excavators
‡ Tractors
‡ Motorcycles
Applications
Relevant Markets
‡ Material Handling
‡ Automotive Maintenance
‡ Transpotation  Shipping
‡ Fleet Maintenance
‡ Mining
‡ Fuel Additives
‡ Engine Catalysts
‡ Construction
‡ Combustion Research
Automotive
Emissions
Product Line
Automotive Emissions
Analyzers
F900
O2  CO
F5000
O2, CO, NO,
CxHy
7899
Hydrocarbon
Detector
O2Robust
Fast
Reliable
Accurate
E Instruments International
P: 215-750-1212 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
www.E-Inst.com
Built with Quality in Mind
N
Forklift  Small Engine Exhaust Gas Analyzer
Pre-Compliance VerificationPre-
CO Safety TestingCO S
Engine Tuning  MaintenanceEngi
CO
Traceable Calibration Certificate
Optional Wireless Bluetooth™ Printer
Oxygen (O2)Measurement
Internal Memory (2,000 Tests)
Measure CO
Up to 50,000 ppm (5%)
Sampling Probe  S-Type Exhaust Fitting
Real-Time Data
Logging Software
g yp h
Ideal For:
Automatic Data Saving Feature
Protective Magnetic Boot
MADE IN USA
Built with Quality in Mind
Ordering Information
Model No. Description
F900
F900-P
Base Kit = CO Sensor, 2,000 Internal Test Memory, PC Software, Bluetooth™, Exhaust Sampling Probe
Base Kit w/ Printer = CO Sensor, 2,000 Internal Test Memory, PC Software, Bluetooth™, Exhaust Sampling Probe
+ Wireless Bluetooth™ Printer
E Instruments International
P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
www.E-Inst.com
˒ CO Sensor (0 to 50,000 ppm, 5%)
˒ Option for O2 Sensor
˒ 2,000 Test Internal Memory
˒ Bluetooth Connectivity
˒ Rechargeable Battery 
AC Charger
˒ ˠˡˇ Gas Sampling Probe  Hose
˒ ŷƼǼÞŸŘ ¯ŸNj Ǣ˚ǻɴƼs ƻNjŸEs ®ÞǼǼÞŘض
˒ ŷƼǼÞŸŘ ¯ŸNj ®ĶsɮÞEĶs ƻNjŸEs ǻÞƼ
˒ Water Trap with Filter Cartridge
˒ Magnetic Rubber Holster
˒ PC Software  USB Cable
˒ Operating Manual
˒ Calibration Certification
˒ Vinyl Carrying Case
˒ ŷƼǼÞŸŘ ¯ŸNj ɟÞNjsĶsǣǣ
Bluetooth™ Printer
All F900 Kits Include:
S-Type Probe Fitting
w/ Exhaust Clamp
 Flexible Tip
Optional Wireless
Bluetooth™ Printer
NEW!!
PC Software
 Wireless Bluetooth
High Range CO Sensor
(0 - 50,000 ppm, 5%)
Internal Memory 
Automatic Data Saving
Gas Sampling Probe
 Magnetic Boot
Applications
Parameter Sensor ResolutionRange Accuracy
ŷ˺
CO
Electrochemical
Electrochemical
0 - 25%
0 - 50,000 ppm
(0 - 5 %)
˟ʳˠ̇
ˠ ƼƼŎ
±0.2% vol
±8 ppm 300 ppm
±4% rdg up to 4000 ppm
̝ˠ˟̇ Nj_¶ ̤ˣ˟˟˟ ƼƼŎ
Technical Specifications
Hands Free Operation Durable Design
Forklifts
Propane Burnishers
 Polishers
Other Small Engines
Propane Grinders
Bulletin:F900.3Ed.01/2017Informationdesignsubjecttochangeatmanufacture’sdiscretion
nical Specificat
PC Software with
Real-Time Automatic
Data Logging
Save, Graph, 
Export Data Wirelessly
via Bluetooth
S-Type P
w/ Exhaust Clamp
 Flexible Tip
sly
E Instruments International
P: 215-750-1212 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
www.E-Inst.com
Automotive  Forklift Exhaust Gas Analyzer
Pre-Compliance VerificationPre-
Vehicle DiagnosticsVehi
Engine Tuning  MaintenanceEngi
Applications:
Built with Quality in Mind
Flexible Exhaust Probe Tip
Sampling Probe with S-Type Exhaust Fitting
Real-Time Data Logging Software
Wireless Bluetooth™ Printer
High Accuracy NDIR Sensors: CO, CO2, HC
For Propane, Diesel, LPG, CNG,  Gasoline Engines
CO
HC
CO2
NOxO2
AFR
Lambda (ʭ)
Built with Quality in Mind
E Instruments International
P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
www.E-Inst.com
˒ CO2 Sensor
˒ CO Sensor
˒ HC Sensor
˒ O2 Sensor
˒ NO/NOx Sensor
˒ Internal Memory (2000 Tests)
˒ Bluetooth Connectivity
˒ Rechargeable Battery  Charger
˒ ˠˡˇˀˢ˟˟ŎŎ Sampling Probe 
ˠ˟˅ˀˢŎ Ǣ ŎƼĶÞض ËŸǣs
˒ S-Type Exhaust Fitting w/ Clamp
˒ Sample Conditioning Unit (SCU)
For Condensation Removal
˒ PC Software  USB Cable
˒ Operating Manual
˒ Calibration Certificate
˒ ŷƼǼÞŸŘ ¯ŸNj ɟÞNjsĶsǣǣ
Bluetooth™ Printer
˒ ŷƼǼÞŸŘ ¯ŸNj ®ĶsɮÞEĶs
Probe Attachment
˒ ŷƼǼÞŸŘ ¯ŸNj ƻNjŸǼsOǼÞɚs N NjNjɴÞض N ǣs
F5000-5GAS Includes:
Optional Wireless
Bluetooth™ Printer
Applications
Bulletin:F5000.3Ed.01/2017Informationdesignsubjecttochangeatmanufacture’sdiscretion
ndBuilt with Quality in Min
Flexible Probe Tip
PC Software with Real-Time
Automatic Data Logging
Technical SpecificationsTe
Parameter Sensor ResolutionRange Accuracy
CO NDIR ˟˚ˠˤ ̇ ˟ʳ˟ˠ ̇ ˟ʳ˟ˡ̇ ̝ˢ̇ Nj_¶ʳ
NDIR ˟˚ˡ˟ ̇ ˟ʳˠ ̇ ˟ʳˠ̇ ̝ˢ̇ Nj_¶ʳNŷ˺
HC NDIR ˟ ˚ ˠ˟ʰ˟˟˟ ƼƼŎ ˠ ƼƼŎ
ŷ˺ Electrochemical ˟ ˚ ˡˤ̇ ˟ʳˠ̇ ̝˟ʳˠ̇ ɚŸĶ
NO/NOx Electrochemical ˟ ˚ ˤʰ˟˟˟ ƼƼŎ ˠ ƼƼŎ
̣ˠˡˤ ƼƼŎ̠̝ˤ ƼƼŎ
ȖƼ ǼŸ ˤʰ˟˟˟ ƼƼŎ̠̝ˣ̇
Light Weight, Portable,  Durable
Printed  Digital Emissions Reports
Rechargeable, Long Life Battery
Vehicles
Trucks
Buses
Forklifts
MADE IN USA
Swivel Handle For
Easy Operation  Transport
S-Type Probe Fitting
 Exhaust Clamp
̝ˢ̇ Nj_¶ʳ ʹˢ˟ˠ˚ˣʰ˟˟˟ ƼƼŎʺ
̝˧ ƼƼŎ ʹ˟˚ˢ˟˟ ƼƼŎʺ
̝ˤ̇ Nj_¶ʳ ʹˣʰ˟˟ˠ˚ˠ˟ʰ˟˟˟ ƼƼŎʺ
Economical  Accurate Combustible Hydrocarbon Gas
Detector for Automotive, Small Engines, and Forklifts
Hydrocarbon Gas Detector
Model 7899
Propane
Propane
Propane
2
0.0 - 5,500 ppm
Automotive Emissions Sampling
Probes  Accessories
12(300mm) Exhaust Gas Sampling Probe with 10'(3m) hose
Standard Probe
12(300mm) Exhaust Gas Sampling Probe with S-Type Fitting, Exhaust Clamp,  10'(3m) hose
Standard Probe
with S-Type
Fitting
12(300mm) Exhaust Gas Sampling Probe with Sample Conditioning Unit (SCU),
S-Type Fitting, Exhaust Clamp,  10'(3m) hose
Automotive
Probe
Flexible Extension for Probes Installed with an S-Type Fitting
Flexible Tip
Extension
Wireless
Bluetooth Printer
Sampling Prob
lamp,  10'(3m) hose
Probes Installed with an S-Type Fitting
Wireless Bluetooth Printer for On-Site Emissions Reports
(Comes With SCU)
Built With Quality In Mind
Product Line
Markets  Applications
‡ Architects  Building Developers
‡ Research  Development
‡ Manufacturing Facilities
‡ Research Laboratories
‡ Greenhouse Buildings
‡ Hospitals  Medical
‡ Building Inspectors
‡ LEED Certification
‡ Industrial Hygiene
‡ Building Hygiene
‡ Energy Auditing
‡ Weatherization
‡ VOC Testing
‡ Warehouses
‡ Universities
‡ Incubators
‡ Airports
IAQ
Indoor Air Quality Monitors
AQ PRO
AQ Incuba
AQ VOC
AQ Comfort
AQ Expert
NONNNNNNNOOOOOOO
CH O2
CO2CCCCCOOOOOOOO22222222
SSSSSSS2H
COCCCCCCCCCOOOOOOOO
% RHRRRRRRHHHHHHHH%%%% RRRRRRRR
NO2NNNNNNNOOOOOOO222222222
SO2
O2
VOC
O3
Protective Magnetic Rubber Boot
Handheld Indoor Air Quality Monitor
PC Software  USB Cable
E Instruments International www.E-Inst.com
P: 215-750-1212
Wireless Communications with
Computer  Remote Printer
Light Weight, Durable,
Handheld Design
F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
CO2
The Latest in Indoor Air Quality Monitoring  Real-Time Data-Logging
for IAQ Analysis in Homes, Schools, Offices, and much more
Real-Time Data-Logging for
Graphs, Data Review, IAQ Reports
“Built with Quality in Mind”
Temp.
% RH
Optional Handheld Probe
Temp.
Differential
Optional Wireless Printer
AQ ComfortAQ Comfort
CO
Add Safety-
Long Lasting Rechargeable Battery
Easy to Use Menu System
Large Internal Memory (2000)
Innovative IAQ Tool for HVAC Professionals
REAL-TIME Continuous Data-Logging
Provide your own Comfort Audit ™
Active Internal Sampling Pump
Compact Handheld Unit
Dew Point
Differential
Pressure
Wet Bulb
Accessories:
MADE IN USA
P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
E Instruments International www.E-Inst.com
Applications
Distributed By:
Bulletin:AQCOMFORT.1Ed.10/2016Informationdesignsubjecttochangeatthemanufacture’sdiscretion.’
(Optional) AQ Gas Real-time
Datalogging Software
®
CO
% RH
CO2
ALL AQ Comfort Kits Include:
Ɣ Continuous Active Internal Sampling Pump
Ɣ Differential Pressure
Ɣ Operating Manual
Ɣ Long Lasting Battery  AC Charger
Ɣ Factory Calibration Certificate
Ɣ Differential Temperature
AQ ComfortAAQQQ ComfortComfortComfort
Temp
¨P
Temp.
CO
Relative Humidity
Ambient
CO2
Temperature
Type K T1
Differential
Pressure
Specifications
Parameter Sensor Range Res. Accuracy
0 - 200 ppm 0.1 ppm ± 1% rdg. ± 0.2 ppmElectrochemical
NDIR 0 - 5,000 ppm 1 ppm
0.1°C/F
Tc K
(0 - 1100°C)
0.1%TFC
Bridge ± 8.0 inH O
± 1% rdg.2
(±20.0 mbar) (0.25 mbar)
(-40 - 125°C)
Electomagnetic Compatibility EN 61326-1, Portable Equipment
Temperature
CO
Features
AQ Comfort ORDERING CODE
AQ Comfort Kit
CO2
Bluetooth
AmbientTemp
%RH, Wet Bulb  Dew Point
Carrying Case
Ŷ
Kit-1 Kit-2
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Kit-3 Kit-4
Internal Memory (2000)
PC Software Kit
ŶŶ
-40 - 257°F
Pt100
20.1 inH O
5°F (3°C) or 2% of rdg1°C/F
0 - 2000°F
5 - 95%
± 0.4°C (0 - 60°C)
± 2% RH
± 2% rdg. ± 10 ppm
PC Software  USB Included
Long Lasting Rechargeable Battery
Barometric Air Pressure
Protective Magnetic Rubber Boot
Large Internal Memory (2000)
Handheld Indoor Air Quality Monitor
E Instruments International www.E-Inst.com
P: 215-750-1212
Wireless Communications with
Computer  Remote Printer
Light Weight, Durable,
Handheld Design
F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
CO
CO
2
Customize UP to 3 Gases
The Latest in Indoor Air Quality Monitoring  Real-Time Data-Logging
for IAQ Analysis in Hospitals, Universities, Labs, Airports, and more
Graphs, Data Review, IAQ reports
AQ PRO
REAL-TIME Continuous Data-Logging
Active Internal Sampling Pump
“Built with Quality in Mind”
H S2
NO2
SO2
Temp
AAQQQ OPROPRO
% RH
Compact Handheld Unit
O2
Optional Handheld Probe
Barometric
Pressure
Formaldehyde
NO
Optional Wireless Printer
MADE IN USA
Real-Time Data-Logging for
attery
oot
a-LLoooogging
mp
(Multiple Parameters - Up to 6 Total)
P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
E Instruments International www.E-Inst.com
AQ PROAQ PRO
Relative Humidity
Temp.
Ambient
Barometric
Pressure
Pressure
Temperature
Type K T1
Differential
Specifications
Parameter Sensor Range Res. Accuracy
Pt100 -40 - 257°F 0.1°C/F ± 0.4°C (0 - 60°C)
Solid State
Tc K 0 - 2000°F 1°C/F ± 2% of rdg
(0 - 1100°C)
5 - 95% RH 0.1% RH ± 2% RHTFC
Bridge ± 8.0 inH O 0.1 inH O ±1% of rdg.2 2
Distributed By:
NO2
SO2
O2
CO
H2S
% RH
CO2
CH O2
Bulletin:AQPRO.5Ed.01/2017Informationdesignsubjecttochangeatthemanufacture’sdiscretion.’
AQ Gas Real-Time
Datalogging Software
260 - 1260 mbar 1 mbar ± 2 mbar
NNNNNNNOOOOOOOO222222222
OOOOOOOOO2222222
CCCCCCCCOOOOOOOO
SSSSSSOOOOOO22222SS
%%%% RRRRRRRHHHHHHH%%%%
HHHHHHH2222222SSSSS
CCCCHHHHHHH OOOOOOOO22222
OO
CCCCCOOOOOOO2222222
(±20.0 mbar) (0.25 mbar)
(-40 - 125°C)
Electomagnetic Compatibility EN 61326-1, Portable Equipment
Operating Manual  Quick Reference Guide
ALL AQ PRO Kits Include:
Temperature, % Relative Humidity
Continuous Active Internal Sampling Pump
Differential Pressure
Long Lasting Battery  AC Charger
Factory Calibration Certificate
AQ PRO ORDERING CODE
Barometric Pressure
PC Software  USB Cable
Bluetooth Connectivity
Protective Carrying Case
Select UP to ANY 3* Gases Below:
Part #: PRO - ___ - ___ - ___
Optional Accessories
Wireless Bluetooth™
Printer
ories
Example: Part #: PRO - C2 - C - H = CO2, CO,  H2S
Parameter Sensor Range Res. Accuracy
O - Oxygen (O ) EC 0 - 25% 0.1 % ± 0.1% vol rdg.2
C2 - Carbon Dioxide (CO ) NDIR 0 - 5,000 ppm 1 ppm ± 2% of rdg. ± 10 ppm2
1
EC 0 - 20 ppmN - Nitrogen Dioxide (NO )2
EC 0 - 250 ppm 0.1 ppm ± 4% of rdg. ± 0.5 ppmX - Nitric Oxide (NO)
2
EC 0 - 20 ppm 0.1 ppm ± 4% of rdg. ± 0.5 ppm- Sulfur Dioxide (SO )2
1
H - Hydrogen Sulfide (H S) 0 - 100 ppm 1 ppm2
±4% of rdg. ± 0.5 ppm
C - Carbon Monoxide (CO) 0 - 200 ppm 0.1 ppm ± 4% of rdg. ± 0.5 ppm
®
REAL-TIME Continuous Data-Logging
F 0 - 10 ppm- Formaldehyde (CH O) ± 5% of rdg. ± 50 ppb
(0 - 10,000 ppb)
(EE900P)
(E85AACSF13)
Pitot Tube
(BB610032)
for Air Velocity
Sampling Probe
0 - 300 ft/sec 1 ft/secAir Velocity Calculated
ElectrochemicalOther Ranges are Available Upon Request Accuracy Based on Laboratory Conditions2.1. 3.
This sensor may have interference from H2 , CO, H2S and other reducing gases such as alcohols4.
2,5
2,5
2,5
2,5
2,5
2,5
2,5
EC
EC
1
3,4
EC
1
1
1
Maximum of TWO (2) Electrochemical (EC) Sensors Per Unit*5.
(AQMET)
Moisture Exchange
Tube for Calibration
± 4% of rdg. ± 0.5 ppm0.1 ppm
1 ppb
Portable Handheld VOC Monitor
E Instruments International www.E-Inst.com
P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
AQ VOC
“Built with Quality in Mind”
AAQQQ CVOCVOC
Accurate VOC Monitoring  Real-Time Data-Logging for Air Quality Analysis
in Industrial Safety, Environmental, Laboratories and other IAQ Applications
Wireless Communications with
Computer  Remote Printer
Light Weight, Durable,
Handheld Design
Real-time Data-Logging Software for
Graphs, Data Review, IAQ reports
VOC
Formaldehyde
CO
CO
2
H S2
NO2
SO2
Temp
% RH
O2
Barometric
Pressure
NO
REAL-TIME Continuous Data-Logging
Active Internal Sampling Pump
Large Internal Memory (2000)
PC Software  USB Included
Long Lasting Rechargeable Battery
Barometric Air Pressure
Protective Magnetic Rubber Boot
Optional Wireless Printer
Optional Handheld Probe
Dynamic PID VOC Sensor Technology
VOC in ppb/μg/m³ or ppm/mg/m³
UPGRADEABLE:
(Add UP TO 2 More Gas Sensors)
0 - 20,000 PPB
0 - 200 PPM
MADE IN USA
a-Logging
mp
)
ttery
ot
m/mg/m³
ensors)
EC
P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
E Instruments International www.E-Inst.com
AQ VOCAQ VOC
Specifications
Parameter Sensor Range Res. Accuracy
Relative Humidity 5 - 95% RHTFC
Distributed By:
NO2
SO2
O2
CO
H2S
% RH
Bulletin:AQPRO.2Ed.01/2017Informationdesignsubjecttochangeatthemanufacture’sdiscretion.’
AQ Gas Real-Time
Datalogging Software
SSSSSOOOOO222222
®
Barometric
Pressure
Solid State 260 - 1260 mbar 1 mbar
NNNNNNNOOOOOOOO22222222
SS
OOOOOOOOO2222222
CCCCCCCCOOOOOOOO
%%%% RRRRRRRHHHHHHHH%
HHHHHHH222222222SSSS
CH O2
CCCCHHHHHH OOOOOOO22222
OO
CO2CCCCCOOOOOO2222222
Temp.
Ambient -40 - 257°F
(-40 - 125°C)
Electomagnetic Compatibility EN 61326-1, Portable Equipment
Optional Accessories
Wireless Bluetooth™
Printer
Electrochemical
EC 0 - 20 ppm- Sulfur Dioxide (SO )
EC ±4% of rdg. ± 0.5 ppmN - Nitrogen Dioxide (NO )2
X - Nitric Oxide (NO)
EC 1 ppbF - Formaldehyde (CH O)2 ± 5% od rdg. ± 50 ppb
2
Other Ranges are Available Upon Request
H - Hydrogen Sulfide (H S) EC 0 - 100 ppm 1 ppm2 ± 4% of rdg. ± 0.5 ppm
Accuracy Based on Laboratory Conditions
C - Carbon Monoxide (CO) EC 0 - 200 ppm 0.1 ppm ± 4% of rdg. ± 0.5 ppm
Optional Gas Sensor Upgrades (Choose UPTo ANY 2)
S
- Carbon Dioxide (CO ) NDIR 0 - 5,000 ppm 1 ppm ± 2% of rdg. ± 10 ppm
O - Oxygen (O ) EC 0 - 25%2
2C2
sories
Sampling Probe
(E85AACSF13)(EE900P)
VOC
Select Your VOC Range:
Parameter Sensor Range
(0 - 46,000 μg/m )3V1- PID 0 - 20,000 ppbLow Range VOC
V2- PID 0 - 200 ppmHigh Range VOC
(0 - 460 mg/m )3
ALL AQ VOC Kits Include:
AQ VOC ORDERING CODE
Part #: VOC- ___ - ___ - ___
Example: Part #: VOC - 1 - F - C2 = 2Low Range VOC, CH O, CO
Operating Manual  Quick Reference Guide
Temperature, % Relative Humidity
Continuous Active Internal Sampling Pump
Long Lasting Battery  AC Charger
Factory Calibration Certificate
Barometric Pressure
PC Software  USB Cable
Bluetooth Connectivity
Protective Carrying Case
REAL-TIME Continuous Data-Logging
2
(0 - 46,000 μg/m )3
(1 μg/m )3
PID 0 - 20,000 ppb 1 ppb ±10 % of rdg. ± 20 ppb
(1 mg/m )
PID
0 - 200 ppm 1 ppm
±10 % of rdg. ± 2 ppm
(0 - 460 mg/m )
3
Low Range VOC
High Range VOC
Pt100
± 2% RH
OR
3
Differential
Pressure
Bridge ±8.0 in H O 0.1 inH O
±1% of rdg.2 2
(±20 mbar) (0.25 mbar)
Air Velocity 0 - 300 ft/secCalculated
Pitot Tube
(BB610032)
for Air Velocity
1
1 2
2
2
2
2
2
2
2.
3,4
1
1
1
1
1. 3.
4. This sensor may have interference from H2 , CO, H2S and other reducing gases such as alcohols
(AQ CAL-ZF)
Zero Filter for
Calibration
(AQMET)
Moisture Exchange
Tube for Calibration
y Conditions
f
Zero Filter for
ation
± 2 mbar
± 0.4°C (0 - 60°C)0.1°C/F
0.1% RH
1 ft/sec
0 - 10,000 ppb
0 - 20 ppm
0.1% ± 0.1% vol rdg.
0 - 250 ppm 0.1 ppm
0.1 ppm
0.1 ppm
± 4% of rdg. ± 0.5 ppm
± 4% of rdg. ± 0.5 ppm
CO˺ Incubator Monitor
The Latest in Incubator Monitoring  Real-Time Data-Logging
for Air Quality Analysis for Incubators
E Instruments International
P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047
www.E-Inst.com
Built with Quality in Mind
AQ INCUBA
Relative Humidity  Temperature
CO2 Measurement Ranges of:
(0 - 5%, 0 - 10%, 0 - 20%)
MADE IN USA
Active Internal Sampling Pump
Long Lasting Rechargeable Battery
Barometric Pressure
CO˺
User Friendly Interface
REAL-TIME Data-Logging
Large Internal Memory (2000)
Real-Time Data-Logging for Graphs,
Data Review,  IAQ Reports
ReaeaRea
Wireless Communications with
Computer  Remote Printer
Wire
Light Weight, Durable,
Hand-Held Design
Lig
Accessories:
Real-Time PC Software
Protective Magnetic Hands-Free Boot
Optional Wireless Printer
Optional Temperature Probe
Temp.
Fast
Reliable
Accurate
Samplililing Pump
ttery
etric Pressure
ce
E Data-Logging
000)
ess CoCommunicationns wiitttttttthn
ommp t
oot
%RH
P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
E Instruments International www.E-Inst.com
Applications
Bulletin:AQINCUBA.1Ed.04/2017Informationdesignsubjecttochangeatthemanufacture’sdiscretion.’
AQ Gas Real-time
Datalogging Software
®
AQ INCUBAAQ INCUBA
% RH
CO2
Temp
P. Bar
O2
Ambient
CO2
Temperature
Type K T1
Specifications
Parameter Sensor Range Res. Accuracy
NDIR
0 - 5%
0.1°C/F
Tc K
(0 - 1100°C)
(-40 - 125°C)
Electomagnetic Compatibility EN 61326-1, Portable Equipment
Temperature
-40 - 257°F
Pt100
5°F (3°C) or 2% of rdg1°C/F
0 - 2000°F
± 0.4°C (0 - 60°C)
± 3% of rdg.0.1%
0 - 25% ± 0.1% vol rdg.ElectrochemicalO2 0.1%
Barometric
Pressure
Solid State 260 - 1260 mbar 1 mbar ± 2 mbar
0 - 10%
0 - 20%
0.1%
0.1%
± 3% of rdg.
± 3% of rdg.
ALL AQ INCUBA Kits Include:
Ɣ Continuous Active Internal Sampling Pump
Ɣ Operating Manual
Ɣ Long Lasting Battery  AC Charger
Ɣ Factory Calibration Certificate
Ɣ Differential Temperature
Features
CO2 Measurement
Ɣ Sampling Hose  Filter
Ɣ Barometric Pressure
Moisture Removal SystemƔ
AQ INCUBA ORDERING CODE
AQ INCUBA Kit
CO2
Ambient Temp
100
O (0 - 25%)2
101
Optional Accessories
Wireless Bluetooth™
Printer
(EE900P)
(E1500SP)
Temperature Probe
(AQMET)
Moisture Exchange
Tube
102
Barometric Pressure
0 - 5% 0 - 10% 0 - 20%
Option Option Option
Relative
Humidity
TFC 5 - 95% RH 0.1% RH ± 2% RH
% Relative Humidity
Ɣ
(TRH-EXT)
Temp.  RH
Extension Probe
Temp.  RH
(AQ650078)
Pack of 3
Moisture Filters
Easy to Use Menu System
Optional Wireless Printer
Barometric Air Pressure
Optional Air Sampling Probe
Large Internal Memory (2000)
Portable Indoor Air Quality Monitor
PC Software  USB Included
Long Lasting Rechargeable Battery
E Instruments International www.E-Inst.com
P: 215-750-1212
Wireless Communications with
Computer  Remote Printer
Light Weight, Durable, and
Easy to Transport Design
F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
CO
CO2
Customize UP to 7 Gases
Providing the latest in Monitoring  Data Logging for IAQ testing in
Buildings, Hospitals, Universities, Labs, Clean Rooms, Airports  more
Portable w/ Swivel Handle
Real-Time Data-Logging Software
For Graphs, Data Review, IAQ Reports
AQ EXPERT
REAL-TIME Continuous Data-Logging
Active Internal Sampling Pump
Dual Temp TcK Inputs
“Built with Quality in Mind”
% RH
Temp
Barometric
Pressure
H S2
VOC
Formaldehyde
O2
NO2
NO
2SO
O3
MADE IN USA
(Multiple Parameters - Up to 12)
P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
E Instruments International www.E-Inst.com
Features
Applications
CO2, CO, % RH, Temp, TVOC’s, O2, NO, NO2, O3, CH2O, SO2, H2S, Barometric Pressure
Easy Calibration
Custom to Your Application REAL-TIME Data Logging
Save and graph using USB
or wireless Bluetooth to a
Computer or Tablet
Made in USA
Designed and manufactured
in the USA
AQ EXPERT
NO
CO2
O2
CO
NO2
SO2
H2S
NNNNNNOOOOOOOOOO
% RH
Built-in menu driven
calibration procedure
CH2O
AQ Gas Real-Time
Datalogging Software
AQ G R l T
®
Up to 7 different toxic gases
to meet the needs of most
air quality analyses
VOCs
VOCs
Sampling Probe
P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
E Instruments International www.E-Inst.com
Accessories
AQ EXPERT
Wireless Bluetooth
Printer
Carrying Case
Air Velocity w/ Pitot Tube
Parameter Sensor Range Res. Accuracy
CO
O2 Electrochemical 0 - 25% 0.1% ±0.1% vo rdg.l
0 - 200 ppm 0.1 ppm ±4% of rdg. ±0.5 ppm
Electrochemical 0 - 100 ppm 1 ppm ±4% of rdg. ± 0.5 ppm
Electrochemical
NDIR 0 - 5,000 ppm 1 ppm ±2% of rdg. ±10 ppm
PID 0 - 20,000 ppb 1 ppb ±10 % of rdg. ± 20 ppb
HR%2±HR%1.0HR%59-5eviticapaCmliFnihT
Pt100 -40 - 257°F 0.1°C/F ±2°F (32-140°F)
Electrochemical 0 - 5 ppm 1 ppb
VOCs
% RH
Temperature
Ambient
Ozone (O )
CO2
H S2
Specifications
CO2 NDIR 0 - 20% 0.1% ±3% of rdg.
VOCs PID 0 - 200 ppm
(-40 - 125°C) (± 0.4°C [0-60°C])
3
(0 - 46,000 μg/m ) (1 μg/m )
(0 - 460 mg/m ) (1 mg/m )3 3
3 3
1 ppm
Other Ranges are Available Upon Request Accuracy Based on Laboratory Conditions1. 2. 3.
1
1
CH O2
bpp05±.gdr% of5bpp1lacimehcortcelE
Barometric
Pressure
Solid State
Temperature
Type K T1  T2
Tc K 0 - 2000°F 1°C/F 2% of rdg.
(0 - 1100°C)
Air Velocity 0 - 300 ft/sec 1 ft/secCalculated
Electrochemical 0 - 20 ppm 0.1 ppmNO2
NO Electrochemical 0 - 250 ppm 0.1 ppm
2SO Electrochemical 0 - 20 ppm 0.1 ppm
Differential
Pressure
Bridge ±40.0 inH O 0.1 inH O ±1% of rdg.2 2
(±100 mbar) (0.25 mbar)
260 - 1260 mbar 1 mbar ±2 mbar
Electromagnetic compatibility EN 61326-1, Portable Equipment
0 - 10,000 ppb
2,3
1
1
1
±10 % of rdg. ± 2 ppm
This sensor may have interference from H2 , CO, H2S and other reducing gases such as alcohols
Moisture Exchange
Tube for Calibration
Ambient Air
Zero Filter
Exchange
Calibration
Ambient Air
Zero Filter
±4% of rdg. ±0.5 ppm
±4% of rdg. ±0.5 ppm
±4% of rdg. ±0.5 ppm
±
±
P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047
E Instruments International www.E-Inst.com
AQ EXPERT ORDERING CODE
Part Number: EXPERT-___-___-___-___-___
(Example: EXPERT-C2-C-V1 =
2
Ambient Temp, % RH, Barometric Pressure,
CO (0-5000 ppm), CO (0-200 ppm), VOC (0-20,000 ppb)
AQ EXPERT Base Unit Including:
- Ambient Temperature, % Relative Humidity
- Barometric Pressure, Wet Bulb  Dew Point
-
- REAL-TIME data logging
- PC Software (with USB Cable)
- Wireless Bluetooth  External Dongle
- Dual-channel TcK (Diff. Temp)
- Differential Pressure
- Operating Manual
- Swivel Handle for Easy Transport
- Rechargeable Battery  AC Charger
- Factory Calibration Certificate
ADD UP TO 7 (SEVEN) ADDITIONAL SENSORS FROM THE LIST BELOW:
PART NUMBER DESCRIPTION
Expert- AQ Expert Base Unit w/ Ambient Temp, %RH, Barometric Pressure
2CO Sensor (0-5,000 ppm)-C2
-C CO Sensor (0-200 ppm)
-V1 VOC Sensor (0-20,000 ppb)
-V2 VOC Sensor (0-200 ppm)
-N NO2 Sensor (0-20 ppm)**
-Z O3 Sensor (0-5 ppm)**
-H H2S Sensor (0-100 ppm)
-O O2 Sensor (0-25%)
-S SO2 Sensor (0-20 ppm)**
-X NO Sensor (0-250 ppm)
-F CH2O Sensor (0-10,000 ppb)
OPTIONAL ACCESSORIES:
PART NUMBER DESCRIPTION
E858140 Protective Carrying Case
E85AACSF13 12” (300mm) Probe, 10’ (3m) Dual Hose
EE900P Bluetooth Wireless Printer
BB610032 12” (300mm) Pitot Tube (Air Velocity)
AACKP01 Differential Pressure Kit
AQ EXPERT
*
*
*
*
* Other Ranges are Available Upon Request Bulletin:AQEXPERT.2Ed.01/2017Informationdesignsubjecttochangeatthemanufacture’sdiscretion.
Note: All 3 O3, NO2,  SO2 Sensors Cannot
Concurrently be Installed on one Instrument
**
- Differential Temperature
*
Continuous Internal Sampling Pump
*
AQ CAL-ZF Ambient Air Zero Filter
AQ MET Moisture Exchange Tube for Calibration
Application Notes
Indoor Air Quality
E Instruments is Proud to Offer A Wide Variety of
In-Depth Application Notes to its Customers
Such As:
The Toxic Effects of Hydrogen Sulfide (H˺S) Gas
From Sewers on Health  Infrastructure
Application Note # AQ-14-0723
VOCs: An Indoor Air Quality Health RiskApplication Note # AQ-13-0601
Warehouses
Why Energy Auditors Need to Measure CO˺Application Note # AQ-14-0313
Manufacturing
Facilities
Architecture
 Buildings
For a Complete List of Our Application Notes
Please Visit Our Website at
www.E-Inst.com
Laboratories
Hospitals
 Medical
Incubators
Research 
Development
Clean Rooms
Building
Hygiene
Industrial
Hygiene
LEED
Certification
Universities
Air Quality Probes  Accessories
12(300mm) Standard Probe
(gas  draft), 1470F (800C) max,
with 10'(3m) dual hose
Standard Probe
Temp.  %RH module extension
cable for testing inside incubators
Temperature  Humidity
Module Extension
Tem
cable
ity
Hose and moisture filter for
testing inside incubatorsIncubator Sampling Hose
Tubing for equalizing humidity
in span gas with atmosphereMoisture Exchange Tube
T
in
(See Figure 1 Below)
Disposable filter for simple zero
calibration of gas sensorsAQ Zero Filter
be
diity
Disposa
calibratFilter
(Figure 1)
For more information about our products please call:
(215) 750-1212 or visit our website at:
www. E-Inst.com
Built With Quality In Mind
E Instruments International is a designer,
manufacturer,  provider of a complete range of
innovative instrumentation solutions including
portable combustion gas and emissions analyzers,
automotive exhaust analyzers, gas leak detectors,
and IAQ Monitors, which we export to over
65 countries worldwide.
more

Contenu connexe

Tendances

Refrigeration brochure sept 2012 (2)
Refrigeration brochure sept 2012 (2)Refrigeration brochure sept 2012 (2)
Refrigeration brochure sept 2012 (2)
a1-cbiss
 
VEGA Pressure & Level Measurement – Building Materials, Stone, Aggregates In...
VEGA Pressure & Level Measurement  – Building Materials, Stone, Aggregates In...VEGA Pressure & Level Measurement  – Building Materials, Stone, Aggregates In...
VEGA Pressure & Level Measurement – Building Materials, Stone, Aggregates In...
Thorne & Derrick UK
 

Tendances (20)

TEMPERATURE HUMIDITY CONTROL CABINETS
TEMPERATURE HUMIDITY CONTROL CABINETSTEMPERATURE HUMIDITY CONTROL CABINETS
TEMPERATURE HUMIDITY CONTROL CABINETS
 
Refrigeration brochure sept 2012 (2)
Refrigeration brochure sept 2012 (2)Refrigeration brochure sept 2012 (2)
Refrigeration brochure sept 2012 (2)
 
SICK - Sensors & Sensor Solutions - Catalogue
SICK - Sensors & Sensor Solutions - CatalogueSICK - Sensors & Sensor Solutions - Catalogue
SICK - Sensors & Sensor Solutions - Catalogue
 
Micro liquid-bath-mlb-30
Micro liquid-bath-mlb-30Micro liquid-bath-mlb-30
Micro liquid-bath-mlb-30
 
Optimizing chemcial industry processes
Optimizing chemcial industry processesOptimizing chemcial industry processes
Optimizing chemcial industry processes
 
Process Analytics Product Catalog
Process Analytics Product CatalogProcess Analytics Product Catalog
Process Analytics Product Catalog
 
GC Cure Pod Mini
GC Cure Pod MiniGC Cure Pod Mini
GC Cure Pod Mini
 
Datasheet Fluke 975. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 975. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke 975. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 975. Hubungi PT. Siwali Swantika 021-45850618
 
Datasheet Fluke 971. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 971. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke 971. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 971. Hubungi PT. Siwali Swantika 021-45850618
 
GPO Customer Presentation
GPO Customer PresentationGPO Customer Presentation
GPO Customer Presentation
 
Pharmaceutical Manufacturing Case Study: Refurbish Old Bioreactor
Pharmaceutical Manufacturing Case Study: Refurbish Old BioreactorPharmaceutical Manufacturing Case Study: Refurbish Old Bioreactor
Pharmaceutical Manufacturing Case Study: Refurbish Old Bioreactor
 
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product BrochureKatronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
 
Equipment for Water Monitoring
Equipment for Water MonitoringEquipment for Water Monitoring
Equipment for Water Monitoring
 
Sick Fluid Sensors
Sick Fluid SensorsSick Fluid Sensors
Sick Fluid Sensors
 
Sika Measuring Metering Calibration Instruments
Sika Measuring Metering Calibration InstrumentsSika Measuring Metering Calibration Instruments
Sika Measuring Metering Calibration Instruments
 
GEBEL & BIOREM BTF & BF BIOLOGICAL ODOUR MANAGEMENT
GEBEL & BIOREM BTF & BF BIOLOGICAL ODOUR MANAGEMENTGEBEL & BIOREM BTF & BF BIOLOGICAL ODOUR MANAGEMENT
GEBEL & BIOREM BTF & BF BIOLOGICAL ODOUR MANAGEMENT
 
Linear instruments
Linear instrumentsLinear instruments
Linear instruments
 
VEGA Pressure & Level Measurement – Building Materials, Stone, Aggregates In...
VEGA Pressure & Level Measurement  – Building Materials, Stone, Aggregates In...VEGA Pressure & Level Measurement  – Building Materials, Stone, Aggregates In...
VEGA Pressure & Level Measurement – Building Materials, Stone, Aggregates In...
 
Cold Rooms by Shri Ram HVAC Technologies Pvt. Ltd. Chennai
Cold Rooms by Shri Ram HVAC Technologies Pvt. Ltd. ChennaiCold Rooms by Shri Ram HVAC Technologies Pvt. Ltd. Chennai
Cold Rooms by Shri Ram HVAC Technologies Pvt. Ltd. Chennai
 
Nunes instruments
Nunes instrumentsNunes instruments
Nunes instruments
 

Similaire à E Instruments Product Catalog 2017

Bacharach eca450 print version
Bacharach eca450 print versionBacharach eca450 print version
Bacharach eca450 print version
a1-cbiss
 
Edurables-profile-16-17
Edurables-profile-16-17Edurables-profile-16-17
Edurables-profile-16-17
Mukesh Goswami
 
Fyrite insight plus
Fyrite insight plusFyrite insight plus
Fyrite insight plus
a1-cbiss
 
Refinery meet
Refinery meet Refinery meet
Refinery meet
rajeshvari
 

Similaire à E Instruments Product Catalog 2017 (20)

Carbon Dioxide Incubator by ACMAS Technologies Pvt Ltd.
Carbon Dioxide Incubator by ACMAS Technologies Pvt Ltd.Carbon Dioxide Incubator by ACMAS Technologies Pvt Ltd.
Carbon Dioxide Incubator by ACMAS Technologies Pvt Ltd.
 
ACAL BFi HVAC Solutions
ACAL BFi HVAC SolutionsACAL BFi HVAC Solutions
ACAL BFi HVAC Solutions
 
ACAL BFi HVAC Solutions
ACAL BFi HVAC SolutionsACAL BFi HVAC Solutions
ACAL BFi HVAC Solutions
 
Bacharach eca450 print version
Bacharach eca450 print versionBacharach eca450 print version
Bacharach eca450 print version
 
Edurables-profile-16-17
Edurables-profile-16-17Edurables-profile-16-17
Edurables-profile-16-17
 
Fyrite insight plus
Fyrite insight plusFyrite insight plus
Fyrite insight plus
 
Vacuum Oven Round by ACMAS Technologies Pvt Ltd.
Vacuum Oven Round by ACMAS Technologies Pvt Ltd.Vacuum Oven Round by ACMAS Technologies Pvt Ltd.
Vacuum Oven Round by ACMAS Technologies Pvt Ltd.
 
Cnt20111201
Cnt20111201Cnt20111201
Cnt20111201
 
Om technical-solutions
Om technical-solutionsOm technical-solutions
Om technical-solutions
 
Refinery meet
Refinery meet Refinery meet
Refinery meet
 
Nebula equipments-pvt-ltd
Nebula equipments-pvt-ltdNebula equipments-pvt-ltd
Nebula equipments-pvt-ltd
 
LN Wrench
LN WrenchLN Wrench
LN Wrench
 
Environmental Monitoring 2019
Environmental Monitoring 2019Environmental Monitoring 2019
Environmental Monitoring 2019
 
Vacuum oven-rectangular
Vacuum oven-rectangularVacuum oven-rectangular
Vacuum oven-rectangular
 
Oil Sensors for Wind Turbines
Oil Sensors for Wind TurbinesOil Sensors for Wind Turbines
Oil Sensors for Wind Turbines
 
Oil sensors for wind turbines
Oil sensors for wind turbinesOil sensors for wind turbines
Oil sensors for wind turbines
 
Professional heat pump manufacturers
Professional heat pump manufacturersProfessional heat pump manufacturers
Professional heat pump manufacturers
 
Brosur bacharach
Brosur bacharachBrosur bacharach
Brosur bacharach
 
Process Instrumentation for the Chemical Industry
Process Instrumentation for the Chemical IndustryProcess Instrumentation for the Chemical Industry
Process Instrumentation for the Chemical Industry
 
HeaterSIM - Fired Heater Technology Brochure.pdf
HeaterSIM - Fired Heater Technology Brochure.pdfHeaterSIM - Fired Heater Technology Brochure.pdf
HeaterSIM - Fired Heater Technology Brochure.pdf
 

Plus de PT. Siwali Swantika

Plus de PT. Siwali Swantika (20)

NetAlly LinkRunner 10G
NetAlly LinkRunner 10GNetAlly LinkRunner 10G
NetAlly LinkRunner 10G
 
NetAlly Etherscope nXG
NetAlly Etherscope nXGNetAlly Etherscope nXG
NetAlly Etherscope nXG
 
Fluke 418x Infrared Calibrator.pdf
Fluke 418x Infrared Calibrator.pdfFluke 418x Infrared Calibrator.pdf
Fluke 418x Infrared Calibrator.pdf
 
Kalibrasi dengan metode komparasi
Kalibrasi dengan metode komparasiKalibrasi dengan metode komparasi
Kalibrasi dengan metode komparasi
 
Kalibrasi Transmitter
Kalibrasi TransmitterKalibrasi Transmitter
Kalibrasi Transmitter
 
Kategori Pengukuran Kelistrikan
Kategori Pengukuran KelistrikanKategori Pengukuran Kelistrikan
Kategori Pengukuran Kelistrikan
 
5 Langkah Kalibrasi RTD
5 Langkah Kalibrasi RTD5 Langkah Kalibrasi RTD
5 Langkah Kalibrasi RTD
 
Keuntungan AnyWare Cloud.pdf
Keuntungan AnyWare Cloud.pdfKeuntungan AnyWare Cloud.pdf
Keuntungan AnyWare Cloud.pdf
 
3 Metode Kalibrasi Sensor Suhu
3 Metode Kalibrasi Sensor Suhu3 Metode Kalibrasi Sensor Suhu
3 Metode Kalibrasi Sensor Suhu
 
10 Langkah Kalibrasi Termometer.pdf
10 Langkah Kalibrasi Termometer.pdf10 Langkah Kalibrasi Termometer.pdf
10 Langkah Kalibrasi Termometer.pdf
 
Pengujian Sistem Photovoltaic.pdf
Pengujian Sistem Photovoltaic.pdfPengujian Sistem Photovoltaic.pdf
Pengujian Sistem Photovoltaic.pdf
 
Fluke Process Calibration Tools Catalog
Fluke Process Calibration Tools CatalogFluke Process Calibration Tools Catalog
Fluke Process Calibration Tools Catalog
 
Fluke Temperature Calibration Catalog
Fluke Temperature Calibration CatalogFluke Temperature Calibration Catalog
Fluke Temperature Calibration Catalog
 
Vitrek Catalog
Vitrek CatalogVitrek Catalog
Vitrek Catalog
 
Rotronic Water Activity Series
Rotronic Water Activity SeriesRotronic Water Activity Series
Rotronic Water Activity Series
 
Rotronic Catalog 2022
Rotronic Catalog 2022Rotronic Catalog 2022
Rotronic Catalog 2022
 
Rotronic RMS Catalog
Rotronic RMS CatalogRotronic RMS Catalog
Rotronic RMS Catalog
 
Fluke Catalog 2022
Fluke Catalog 2022Fluke Catalog 2022
Fluke Catalog 2022
 
Metrel Catalog 2022
Metrel Catalog 2022Metrel Catalog 2022
Metrel Catalog 2022
 
NetAlly Product Family Brochure
NetAlly Product Family BrochureNetAlly Product Family Brochure
NetAlly Product Family Brochure
 

Dernier

Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Dr.Costas Sachpazis
 
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort ServiceCall Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
9953056974 Low Rate Call Girls In Saket, Delhi NCR
 
AKTU Computer Networks notes --- Unit 3.pdf
AKTU Computer Networks notes ---  Unit 3.pdfAKTU Computer Networks notes ---  Unit 3.pdf
AKTU Computer Networks notes --- Unit 3.pdf
ankushspencer015
 
result management system report for college project
result management system report for college projectresult management system report for college project
result management system report for college project
Tonystark477637
 
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Christo Ananth
 

Dernier (20)

Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01
 
UNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICS
UNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICSUNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICS
UNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICS
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
 
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort ServiceCall Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
 
AKTU Computer Networks notes --- Unit 3.pdf
AKTU Computer Networks notes ---  Unit 3.pdfAKTU Computer Networks notes ---  Unit 3.pdf
AKTU Computer Networks notes --- Unit 3.pdf
 
result management system report for college project
result management system report for college projectresult management system report for college project
result management system report for college project
 
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptxBSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
 
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
 
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
 
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
 
Intze Overhead Water Tank Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank  Design by Working Stress - IS Method.pdfIntze Overhead Water Tank  Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank Design by Working Stress - IS Method.pdf
 
Vivazz, Mieres Social Housing Design Spain
Vivazz, Mieres Social Housing Design SpainVivazz, Mieres Social Housing Design Spain
Vivazz, Mieres Social Housing Design Spain
 
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordCCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
 
Java Programming :Event Handling(Types of Events)
Java Programming :Event Handling(Types of Events)Java Programming :Event Handling(Types of Events)
Java Programming :Event Handling(Types of Events)
 
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlyKubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghly
 
UNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular ConduitsUNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular Conduits
 
Unit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfUnit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdf
 
University management System project report..pdf
University management System project report..pdfUniversity management System project report..pdf
University management System project report..pdf
 

E Instruments Product Catalog 2017

  • 1. www.E-Inst.com P: (215) 750-1212 F: (215) 750-1399 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 2017 Product Catalog Built With Quality In Mind Emiss ions Analyzers Combustion Ana lyzers Ind oor Air Quality Automotive Emiss ions
  • 2. E Instruments International Built With Quality In Mind The E Instruments organization is a privately held company originally incorporated in 2001 by experts with over 30 years of experience in design manufacturing and industrial applications. The initial business mission was to provide high quality instrumentation designed to measure the flue gas emissions from industrial applications. After many years of successful growth and recognition in the international markets, the company was incorporated as E Instruments International LLC with the expanded mission to design, manufacture and market a complete range of innovative instrumentation solutions encompassing portable Emissions, Exhaust, and Combustion Analyzers, and Indoor Air Monitors especially designed for the industrial, HVAC, commercial, automotive, and institutional markets worldwide. E Instruments’ continued success is based on our commitment to: With manufacturing facilities in the USA and Europe, our team continues to grow and we are currently exporting to over 65 countries worldwide. ABOUT US 1) Design instruments to meet our customer’s needs 2) Apply our expertise to monitoring unique and specialized applications 3) Deliver Analyzers and Monitors Built with Quality in Mind 4) Provide excellent Customer Support
  • 3. Contents HVAC Combustion Analyzers Page 4-19 Portable Emissions Analyzers Page 20-33 Indoor Air Quality Monitors Page 42-57 & Calibration Services NONNNNNNNOOOOOOO CH O2 CO2CCCCCOOOOOO22222222 SSSSSSS2H CCCOOO % RH%%%% RRRHHHH%%%% RRRRRHHHHH NO2NNNNNNNNNNNOOOOOOOO22222222 SO2 O2 Quality Control, Customer Support Qualified customer support & technical specialists will work with you and your team with any product and application questions you may have on a timely manner. We appreciate that your time is precious and that your analyzers/instruments are important tools for your business. Our modern Calibration Laboratories provide high quality calibration services and certificates using EPA protocol gases and NIST traceable calibration standards. Additional traceable calibration services are offered at our ISO 17025 & ISO 9001 accredited laboratory. Our Distribution network offers sales and technical product support in many countries around the world. E Instruments’ quality control premise encompasses the complete business process from design, manufacturing, administration, customer support, and after sale Calibration & repair Services. Our team of qualified professionals is fully committed to our basic philosophy of “Built with Quality in Mind”, which applies to all products and services offered by our company. Automotive Exhaust Gas Analyzers Page 34-41
  • 4. Markets & Applications ‡ Boiler, Furnace, and Burner Manufacturers ‡ Residential, Commercial,& Light Industrial ‡ Condensing Boilers and Furnaces ‡ Boilers, Furnaces, and Heaters ‡ HVAC & Controls Wholesale ‡ HVAC Technical Schools ‡ Retail, Malls, Hotels ‡ Energy Auditing ‡ Weatherization ‡ Hospitals ‡ Schools Built With Quality In Mind HVAC Product Line
  • 5. Combustion Analyzers 4500 O2, CO, NO NO2, SO2 7899 Gas Leak Detector 1500 O2, COO2, C900 O2, CO, NO, CxHy O2, C C700 O2, CO
  • 6. Built With Quality In Mind ‡ Gas & Diesel Engines ‡ Laboratory Analysis ‡ Gas Turbines ‡ Incinerators ‡ Furnaces ‡ Heaters ‡ Boilers ‡ Kilns Applications Relevant Markets ‡ Chemical & Industrial Processes ‡ Cement & Mineral Processing ‡ Natural Gas Compression ‡ Universities & Research ‡ Utilities & Power Plants ‡ Power Generation ‡ Petrochemical ‡ Heat Treating ‡ Biomass ‡ Marine ‡ Mining Industrial Product Line
  • 7. Emissions Analyzers 1500 O2, COO 4500 O2, CO, NO NO2, SO2, CxHy E8500 Plus Up to 9 Gas Sensors O2, CO, NO, NO2, SO2, H2S NDIR: CO2, High CO, CxHy PID: VOC O 2, 6000 O2, CO, NO NO2, SO2, CxHy, H2S (Max 4 Gas Sensors) (4 or 5 Gas Sensors) 4 Gas Sensors)4 Gas E9000 Up to 9 Gas Sensors O2, CO, NO, NO2, SO2, H2S NDIR: CO2, High CO, CxHy Heated Sample Line
  • 8. Built with Quality in MindFor Boiler & Burner Set-Up, Servicing, & Maintenance Economical Residential Combustion Analyzer Robust Fast Reliable Accurate CO CO2 O2 Draft & Differential Pressure Built-In Manometer Ambient CO Monitor Flue & Ambient Temp CO Sensor with NOx Filter Combustion Efficiency PC Software w/ Auto Saving Unbreakable Metal Connections 5 Tools-In-One TRUE High- Efficiency for ALL Condensing Systems TTTT ffi i Automatic, EfEf TRUE High y f d i S t TTTTatic, Calculations Field ReplaceableFiFieldFie Pre-Calibrated Sensors Wireless Bluetooth™ PrinterWirreWire Built with QuaMaintenance ure p Ox Filter iency g i ns e E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com
  • 9. CO CO˺ Tair Tgas Differential Temp Pressure/Draft Excess Air Efficiency Warranty Electrochemical Calculated Pt100 Tc K Calculated Calculated Calculated Semiconductor 2 years: Analyzer + Sensors 0 - 8000 ppm 0 - 99.9% -10 to 212°F -10 to 1830°F -10 to 1830°F ±0 - 80 inH˺0 0 - 850% 0 - 100% 1 ppm 0.1% 0.1°F 0.1°F 0.1°F 0.001 inH˺0 1% 0.1% Parameter Sensor ResolutionRange Accuracy O˺ Electrochemical 0 - 25% 0.1% ±0.2% vol ±8 ppm <400 ppm ±1°F ±1% rdg. ±2°F Built with Quality in Mind Ordering Information Model No. Description 700 - A 700 - AP Model 700 Kit = O˺, CO, CO˺, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air, 300 Internal Test Memory, PC Software Included + New Auto Outdoor Air Temp. Saving for TRUE Efficiency Calculations Model 700 Kit w/ Printer = O˺, CO, CO˺, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air, 300 Internal Test Memory, PC Software Included + Wireless Bluetooth™ Printer + New Auto Outdoor Air Temp. Saving for TRUE Efficiency Calculations E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com ˒ New Auto Outdoor Air Temp ˒ O˺, CO, CO˺ ˒ Combustion Efficiency, Losses, & Excess Air ˒ CO Air Free ˒ Draft & Differential Pressure ˒ Temperature Measurements ˒ 300 Test Internal Memory ˒ Bluetooth Connectivity ˒ Long Lasting Rechargeable Battery & AC Charger ˒ Gas Sampling Probe & Hoses ˒ Water Trap with Filter Cartridge ˒ Operating Manual ˒ Calibration Certification All Model 700 Kits Include: ˒ Magnetic Rubber Holster ˒ PC Software & USB Cable ˒ Vinyl Carrying Case ˒ ɟÞNjsĶsǣǣ DĶȖsǼŸŸǼÌ˗ ƻNjÞŘǼsNj Optional Wireless Bluetooth™ Printer (No More Lining Up Infrared Printers!) NNNEEEWW!!! Internal Memory & PC Software Included Pre-Calibrated Field Replaceable Sensors 10 Fuel / Oil Types Including Bio-Heat 5% Unbreakable Metal Connections Outdoor Air Temp. & High Efficiency (Condensing Systems) H˺ Compensated w/ Built-In NOx Filter ±10 % rdg for >2000 ppm ±5% rdg up to 2000 ppm O Air Temp & Automatic mpppp. & Higggh y sing Systems) Calculations AA Options:
  • 10. The Latest in Combustion Analysis Technology CO CO2 O2 Field Replaceable SensorsFiFieFi Robust Fast Reliable Accurate E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind Wireless Bluetooth™ Printer N o w W ith WirelessBl uetooth™ Printer Economical Combustion & Emissions Analyzer Upgradeable to NO/NOxUpgU Draft & Differential Pressure Built-In Manometer Ambient CO Monitor Flue & Ambient Temp Upgradeable to NO/NOx Combustion Efficiency PC Software w/ Auto Saving Unbreakable Metal Connections TRUE High- Efficiency for ALL Condensing Systems TTT Effi i Automatic, E TRUE High y f d i S t TTTatic, Calculations 5 Tools-In-One NOx d Replaceablieldie eless Bluetooth™ PrinterWiWireWir N o w W ith WirelessBl uetooth™ Printer mp o NO/NOx Efficiency In-One
  • 11. Built with Quality in Mind Ordering Information Model No. Description 900 - 2 900 - 3 900 - 3P Base Kit = O˺, CO, CO˺, Upgradeable to NO/NOx, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air, 600 Internal Test Memory, PC Software Included + New Auto Outdoor Air Temp. Saving for TRUE Efficiency Calculations 900 - 2P Base Kit w/ Printer = O˺, CO, CO˺, Upgradeable to NO/NOx, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air, 600 Internal Test Memory, PC Software Included + Wireless Bluetooth™ Printer + New Auto Outdoor Air Temp. Saving for TRUE Efficiency Calculations NOx Base Kit = O˺, CO, CO˺, NO/NOx Included, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air, 600 Internal Test Memory, PC Software Included + New Auto Outdoor Air Temp. Saving for TRUE Efficiency Calculations NOx Kit w/ Printer = O˺, CO, CO˺, NO/NOx Included, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air, 600 Internal Test Memory, PC Software Included + Wireless Bluetooth™ Printer + New Auto Outdoor Air Temp. Saving for TRUE Efficiency Calculations E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com ˒ New Auto Outdoor Air Temp ˒ O˺, CO, CO˺ ˒ Upgradeable to NO/NOx ˒ Combustion Efficiency, Losses, & Excess Air ˒ CO Air Free ˒ Draft & Differential Pressure ˒ Temperature Measurements ˒ 600 Test Internal Memory ˒ Bluetooth Connectivity ˒ Long Lasting Rechargeable Battery & AC Charger ˒ Gas Sampling Probe & Hoses ˒ Water Trap with Filter Cartridge ˒ Magnetic Rubber Holster ˒ PC Software & USB Cable ˒ Operating Manual ˒ Calibration Certification ˒ Vinyl Carrying Case ˒ ŷƼǼÞŸŘ Ķ ɟÞNjsĶsǣǣ DĶȖsǼŸŸǼÌ˗ ƻNjÞŘǼsNj All Model 900 Kits Include: Optional Wireless Bluetooth™ Printer (No More Lining Up Infrared Printers!) NNEEWW!!! Internal Memory & PC Software Included Pre-Calibrated Field Replaceable Sensors 10 Fuel / Oil Types Including Bio-Heat 5% Unbreakable Metal Connections Outdoor Air Temp. & High Efficiency (Condensing Systems) CO CO˺ NO NOx Tair Tgas Differential Temp Pressure/Draft Excess Air Efficiency Warranty Electrochemical Electrochemical Calculated Calculated Pt100 Tc K Calculated Calculated Calculated Semiconductor 2 years: Analyzer + Sensors 0 - 8000 ppm 0 - 99.9% 0 - 4000 ppm 0 - 5000 ppm -10 to 212°F -10 to 1830°F -10 to 1830°F ±0 - 80 inH˺0 0 - 850% 0 - 100% 1 ppm 0.1% 1 ppm 1 ppm 0.1°F 0.1°F 0.1°F 0.001 inH˺0 1% 0.1% Parameter Sensor ResolutionRange Accuracy O˺ Electrochemical 0 - 25% 0.1% ±0.2% vol ±8 ppm <400 ppm ±5 ppm <100 ppm ±5% rdg up to 1000 ppm ±10% rdg for >4000 ppm ±1°F ±1% rdg. ±2°F H˺ Compensated w/ Built-In NOx Filter ±10 % rdg for >2000 ppm ±5% rdg up to 2000 ppm O Air Temp & Automatic mpppp. & Higggh y sing Systems) Calculations AA
  • 12. The Latest in Combustion Analysis Technology CO CO˺ O2 Field Replaceable SensorsFiFieFie Robust Fast Reliable Accurate E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind Wireless Bluetooth™ Printer Combustion & Safety Analyzer Measure CxHy Hydrocarbons for SafetyMeaM Draft & Differential Pressure Built-In Manometer Ambient CO Monitor Flue & Ambient Temp Burner/Boiler Safety Combustion Efficiency PC Software w/ Auto Saving Unbreakable Metal Connections Ideal for Maintaining & Troubleshooting Residential Commercial Burners 5 Tools-In-One CxHy d Replaceablelde eless Bluetooth™ PrinterWiWireWir p afety Efficiency n-One
  • 13. CO CO˺ Tair Tgas Differential Temp Pressure/Draft Excess Air Efficiency Warranty Electrochemical Calculated Pt100 Tc K Calculated Calculated Calculated Semiconductor 2 years: Analyzer + Sensors 0 - 8000 ppm 0 - 99.9% -10 to 212°F -10 to 1830°F -10 to 1830°F ±0 - 80 inH˺0 0 - 850% 0 - 100% 1 ppm 0.1% 0.1°F 0.1°F 0.1°F 0.001 inH˺0 1% 0.1% Parameter Sensor ResolutionRange Accuracy O˺ Electrochemical 0 - 25% 0.1% ±0.2% vol ±10 ppm <400 ppm ±1°F ±1% (-4.014 - 0.806 inH˺0) ±0.008 (-0.802 - 0.802 inH˺0) ±1% (0.806 - 0.292 inH˺0) ±2°F Built with Quality in Mind Ordering Information Model No. Description 900 - C CxHy Base Kit = O˺, CO, CO˺, CxHy Included, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air, 600 Internal Test Memory, PC Software Included + New Auto Outdoor Air Temp. Saving for TRUE Efficiency Calculations 900 - CP CxHy Kit w/ Printer = O˺, CO, CO˺, CxHy Included, Draft, Diff. Pressure, Flue/Air Temperature, Efficiency, Excess Air, 600 Internal Test Memory, PC Software Included + Wireless Bluetooth™ Printer + New Auto Outdoor Air Temp. Saving for TRUE Efficiency Calculations E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com Optional Wireless Bluetooth™ Printer NNEEWW!! Pre-Calibrated Field Replaceable Sensors 10 Fuel / Oil Types Including Bio-Heat 5% Unbreakable Metal Connections Outdoor Air Temp. & High Efficiency (Condensing Systems) H˺ Compensated w/ Built-In NOx Filter ±10 % rdg for >2000 ppm ±5% rdg up to 2000 ppm O Air Temp & Automatic mpppp. & Higggh y sing Systems) Calculations AA CxHy (HC) Pellistor 0 - 5% 0.01% ±5% Full Scale Troubleshoot Burner Defects Draft/Air Supply Malfunction Damaged or Clogged Burner Tip
  • 14. Residential & Commercial COMBUSTION ANALYZER The Latest in Combustion Analysis Technology CO CO2 O2 BUILT-IN PrinterBUIIUI Full COLOR Graphic DisplayFulFullFull Field Replaceable SensorsFiFielFie Robust Fast Reliable Accurate 5 Tools-In-One Built-In Manometer Ambient CO Monitor Flue & Ambient Temp Draft & Differential Pressure Combustion Efficiency E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com ial USTIOCOMBUS LLT IN PrinterLTI One r Temp ential Pressure Built with Quality in Mind PC Software w/ Auto Saving r Unbreakable Metal Connections , TRUE High- Efficiency for ALL Condensing Systems EEffii iiE Automatic TTRRUUE High yy f d i S t ,,,,attiicc Calculations ols-In-OOne
  • 15. resse E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind O˺ CO CO˺ Tair Tgas Differential Temp. Pressure/Draft Excess Air Efficiency Warranty Parameter H˺ Compensated w/ Built-In NOx Filter Sensor Electrochemical Electrochemical Calculated Pt100 Tc K Calculated Semiconductor Calculated Calculated Range Resolution Accuracy 0 - 25 % 0 - 8000 ppm 0 - 99.9% -10 to 212 ̿F -10 to 1830 ̿F -10 to 1830 ̿F ±0 - 80 inH˺O 0 - 850% 0 - 100% 0.1 % 1 ppm 0.1 % 0.1 ̿F 0.1 ̿F 0.1 ̿F 0.001 inH˺O 1 % 0.1 % ±0.2 % vol ±8 ppm <400 ppm ±5 % rdg up to 2000 ppm ±10 % rdg for >2000 ppm ±1 ̿F ±2 ̿F ±1 % rdg. 2 years: Analyzer + Sensors Ordering Information Model No. Description 1500-1 Model 1500 Base Kit = Analyzer w/ O˺, CO, CO˺, Efficiency, Excess Air, Draft, Pressure, Temp, Rechargeable Battery & AC Plug, 10’ Dual Hose, 12” Probe, Vinyl Case, Calibration Certificate, Operating Manual, Cheat Sheet, Water Trap, Paper Roll, 2000 Internal Data Storage, PC Software, Bluetooth™ Connectivity, Automatic Outdoor Air Temperature Saving for ALL 90%+ Systems & Condensing Systems for TRUE Efficiency Calculations + Built-In Printer + New Android App Included 1500-Oil Standard 1500-1 Kit PLUS: Oil Smoke Pump, Smoke Filter Papers, and Comparison Chart PC Software, Bluetooth, & App Included Large Color Graphic Display All Model 1500 Kits Include: Magnetic Rubber Holster Pre-Calibrated Field Replaceable Sensors BUILT-IN PRINTER (NON-Fading Paper) Simple Menu Interface Full COLOR Graphic Display Unbreakable Metal Connections Outdoor Air Temp. & High- Efficiency (Condensing Systems) ˒ New Android App ˒ New Auto Outdoor Air Temp. ˒ Built-In Printer ˒ Large Color Display ˒ O˺, CO, CO˺ ˒ Combustion Efficiency, Losses, Excess Air ˒ CO Air Free ˒ Draft & Differential Pressure ˒ Temperature Measurements ˒ 2000 Test Internal Memory ˒ Bluetooth Connectivity ˒ Long Lasting Rechargeable Battery & AC Charger ˒ Gas Sampling Probe & Hose ˒ Water Trap with Filter Cartridge ˒ Magnetic Rubber Holster ˒ PC Software & USB Cable ˒ Operating Manual ˒ Calibration Certificate ˒ Carrying Case O Air Temp &A Automatic mppp. & High- y sing S stems) Calculations
  • 16. Industrial Combustion Gas & Emissions Analyzer CO CO2 O2 Robust Fast Reliable Accurate Internal Memory (2000 Tests) 2 Channel Thermometer CO Sensor w/ NOx Filter Draft & Differential Pressure E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com is & Emi re Built with Quality in Mind BUILT-IN PrinterBUILFull COLOR Graphic DisplayFull Customizable Display Screen & Print-Out Pre-Calibrated, Field Replaceable Gas Sensors Combustion Efficiency Up To FOUR Gas Sensors NO2 SO2 NO NOx CxHy (HC) Handheld Versatile Gas Analyzer for Emissions Monitoring of Boiler, Engine, Furnace, and Other Combustion Applications Dilution Pump For CO Auto-Range Measurements Up To 10% PC Software with Bluetooth Total NOx Capable NEW Sample Conditioning Unit For Low NOx & Low SO2 Applications Automatic Data Saving N SSam ple Conditioning Unit For Low NOx & SO2
  • 17. E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind Sample Conditioning Unit For Low NOx & SO˺ Applications Removes Moisture at the Probe For More Accurate Low NOx & SO2 Measurements O˺ CO CO˺ Tair Tgas Pressure/Draft Excess Air Efficiency Parameter H˺ Compensated w/ Built-In NOx Filter Sensor Electrochemical Electrochemical Calculated Pt100 Tc K Semiconductor Calculated Calculated Range Resolution Accuracy 0 - 25 % 0 - 8000 ppm 0 - 99.9% -10 to 212 ̿F -4 to 2280 ̿F ±0 - 80 inH˺O 0 - 850% 0 - 100% 0.1 % 1 ppm 0.1 % 0.1 ̿F 0.1 ̿F 0.001 inH˺O 1 % 0.1 % ±0.2 % vol ±8 ppm (0 - 200ppm) ±5 % rdg (201 - 2000ppm) ±10 % rdg (2001 - 8000ppm) ±1 ̿F ±0.5 ̿C (-20 to 100 ̿C) ±1.0% rdg CO DILUTED Electrochemical 0.8% - 10.00% 0.01% ±10% rdg NO Electrochemical NO˺ Electrochemical Low NO and/or Low NO˺ NOx Calculated SO˺ Electrochemical Electrochemical 0 - 5000 ppm 0 - 1000 ppm 0 - 100.0 ppm 0 - 5000 ppm 0 - 5000 ppm 1 ppm 1 ppm 0.1 ppm 1 ppm 1 ppm ±5 ppm (0 - 100 ppm) ±5% rdg (101 - 5000ppm) ±5 ppm (0 - 100 ppm) ±5% rdg (101 - 1000ppm) ±1.5 ppm (0.0 - 40.0ppm) ±5% rdg (40.1 - 100.0ppm) ±5 ppm (0 - 100ppm) ±5% rdg (101 - 5000ppm) -20 to 1250 ̿C -10 to 100 ̿C ±1 ̿C ̝˟ʳˤ̇ Nj_¶ ʹˠ˟ˠ ǼŸ ˠˡˤ˟ ̿C) 0.1 ̿C 0.1 ̿C Ordering Information Model No. Description 4500 with O˺, CO, NO/NOx, SO˺ Gas Sensors & CO Dilution Auto-Range to 50,000 ppm 4500 with O˺, CO, NO/NOx Gas Sensors Installed, Upgradeable to 4th Gas Sensor4500-3 4500 with O˺, CO, NO/NOx, NO˺ Gas Sensors & CO Dilution Auto-Range to 50,000 ppm4500-N 4500-S Probes & Hoses Standard: 12”, 300mm Probe, 1470̿F/800̿C max with 10’/3m Dual Hose Long: 30”, 750mm Probe, 1470̿F/800̿C max with 10’/3m Dual Hose Long & High Temp: 40”, 1m Probe, 2190̿F/1200̿C max, with 10’/3m Hose Hose Extensions: 10’/3m Length Available All Model 4500 Kits Include: ˒ Built-In Printer ˒ Draft & Differential Pressure ˒ Temperature Measurements ˒ Calculation for CO˺, Efficiency & Excess Air ˒ Rechargeable Batteries & AC Charger ˒ Gas Sampling Probe & Hoses ˒ Water Trap with Filter Cartridge ˒ Magnetic Rubber Holster ˒ 2000 Test Internal Memory ˒ PC Software & USB Cable ˒ Bluetooth Module (Internal) ˒ Operating Manual ˒ Calibration Certificate ˒ ABS Hard Plastic Carrying Case 4500 with O˺, CO, NO/NOx, CxHy (HC) Gas Sensors & CO Dilution Auto-Range to 50,000 ppm4500-C CxHy (HC) Pellistor 0 - 5% 0.01% ±5% Full Scale Bulletin:E4500.3Ed.01/2017Information&designsubjecttochangeatmanufacture’sdiscretion Low SO˺ Electrochemical 0 - 100.0 ppm 0.1 ppm ±1.5 ppm (0.0 - 40.0ppm) ±5% rdg (40.1 - 100.0ppm) 4500-NLow 4500-SLow 4500 with O˺, CO, Low NO/NOx, Low NO˺ Gas Sensors & CO Dilution Auto-Range to 50,000 ppm 4500 with O˺, CO, NO/NOx, Low SO˺ Gas Sensors & CO Dilution Auto-Range to 50,000 ppm High Temperature Probe & Sintered Filter Available P eeeeree ed FFilter Avvailableinte& Sintered FFilter Av
  • 18. Six Gas Industrial Emissions Analyzer CO CO2 O2 Robust Fast Reliable Accurate Internal Memory (2000 Tests) Low NOx & Low SO˺ Capable CO Sensor w/ NOx Filter Draft & Differential Pressure E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com Capable r ure Built with Quality in Mind BUILT-IN PrinterBUILFull COLOR Graphic DisplayFull Customizable Display Screen & Print-Out Pre-Calibrated, Field Replaceable Gas Sensors Combustion Efficiency Up To SIX Gas Sensors Hand-Held Versatile Gas Analyzer for Emissions Monitoring of Boiler, Engine, Furnace, and Other Combustion Applications Dilution Pump For CO Auto-Range Measurements Up To 10% PC Software with Bluetooth Total NOx Capable NEW Sample Conditioning Unit For Low NOx & Low SO˺ Applications Automatic Data Saving Sam ple Conditioning Unit For Low NOx & SO2 NO˺ SO˺ NO NOx CxHy (HC) H˺Ǣ
  • 19. E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind Sample Conditioning Unit For Low NOx & SO˺ Applications Removes Moisture at the Probe For More Accurate Low NOx & SO2 Measurements O˺ CO CO˺ Tair Tgas Pressure/Draft Excess Air Efficiency Parameter H˺ Compensated w/ Built-In NOx Filter Sensor Electrochemical Electrochemical Calculated Pt100 Tc K Semiconductor Calculated Calculated Range Resolution Accuracy 0 - 25 % 0 - 8000 ppm 0 - 99.9% -10 to 212 ̿F -4 to 2280 ̿F ±0 - 80 inH˺O 0 - 850% 0 - 100% 0.1 % 1 ppm 0.1 % 0.1 ̿F 0.1 ̿F 0.001 inH˺O 1 % 0.1 % ±0.2 % vol ±8 ppm (0 - 200ppm) ±5 % rdg (201 - 2000ppm) ±10 % rdg (2001 - 8000ppm) ±1 ̿F ±0.5 ̿C (-20 to 100 ̿C) ±1.0% rdg CO DILUTED Electrochemical 0.8% - 10.00% 0.01% ±10% rdg NO Electrochemical NO˺ Electrochemical Low NO and/or Low NO˺ NOx Calculated SO˺ Electrochemical Electrochemical 0 - 5000 ppm 0 - 1000 ppm 0 - 100.0 ppm 0 - 5000 ppm 0 - 5000 ppm 1 ppm 1 ppm 0.1 ppm 1 ppm 1 ppm ±5 ppm (0 - 100 ppm) ±5% rdg (101 - 5000ppm) ±5 ppm (0 - 100 ppm) ±5% rdg (101 - 1000ppm) ±1.5 ppm (0.0 - 40.0ppm) ±5% rdg (40.1 - 100.0ppm) ±5 ppm (0 - 100ppm) ±5% rdg (101 - 5000ppm) -20 to 1250 ̿C -10 to 100 ̿C ±1 ̿C ̝˟ʳˤ̇ Nj_¶ ʹˠ˟ˠ ǼŸ ˠˡˤ˟ ̿C) 0.1 ̿C 0.1 ̿C Ordering Information Model No. Description E6000 with O˺, CO, NO, SO˺, H˺S Gas Sensors Installed, Upgradeable to 6th Gas Sensor* E6000 with O˺, CO, NO, NO˺ , SO˺ Gas Sensors Installed, Upgradeable to 6th Gas Sensor*E6000-5DS E6000 with O˺, CO, NO, NO˺, CxHy(HC) Gas Sensors Installed, Upgradeable to 6th Gas Sensor*E6000-5DC E6000-5SH Probes & Hoses Standard: 12”, 300mm Probe, 1470̿F/800̿C max with 10’/3m Dual Hose Long: 30”, 750mm Probe, 1470̿F/800̿C max with 10’/3m Dual Hose Long & High Temp: 40”, 1m Probe, 2190̿F/1200̿C max, with 10’/3m Hose Hose Extensions: 10’/3m Length Available All E6000 Kits Include: ˒ Built-In Printer ˒ CO Dilution Auto-Range to 10% ˒ Draft & Differential Pressure ˒ Temperature Measurements ˒ Calculation for CO˺, Efficiency & Excess Air ˒ Rechargeable Batteries & AC Charger ˒ Gas Sampling Probe & Hoses ˒ Water Trap with Filter Cartridge ˒ Magnetic Rubber Holster ˒ 2000 Test Internal Memory ˒ PC Software & USB Cable ˒ Bluetooth Module (Internal) ˒ Operating Manual ˒ Calibration Certificate ˒ ABS Hard Plastic Carrying Case ˒ Android Smart Phone App CxHy (HC) Pellistor 0 - 5% 0.01% ±5% Full Scale Bulletin:E6000.2Ed.01/2017Information&designsubjecttochangeatmanufacture’sdiscretion Low SO˺ Electrochemical 0 - 100.0 ppm 0.1 ppm ±1.5 ppm (0.0 - 40.0ppm) ±5% rdg (40.1 - 100.0ppm) E6000-5SC E6000 with O˺, CO, NO, SO˺, CxHy(HC) Gas Sensors Installed, Upgradeable to 6th Gas Sensor* High Temperature Probe & Sintered Filter Availabled FFilter Aveeeereee ed vailable& Sinteered FFilter Avere *All Configurations Available With Low NO, Low NO˺, and/or Low SO˺ Sensors H˺S Electrochemical 0 - 500 ppm 0.1 ppm ±5 ppm (0.0 - 125.0ppm) ±4% rdg (125.1 - 500.0ppm) E6000-6DSH E6000-6DSC E6000 with O˺, CO, NO, NO˺, SO˺, H˺S Gas Sensors Installed* E6000 with O˺, CO, NO, NO˺, SO˺, CxHy(HC) Gas Sensors Installed*
  • 20. Portable Industrial Flue Gas & Emissions Analyzer Complete Portable Emissions Analyzer with up to Nine Gas Sensors for Boiler, Engine, Furnace, and other Combustion Applications CO O˺ E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind NO E8500 PLUS Built-In Thermoelectric Chiller Up to 9 Total Gas Sensors MADE IN USA CO Dilution Auto-Range Automatic Condensate Drain Long Life Rechargeable Battery Upgraded Memory (2000 Tests) True NOx & Low NOx Measurements High Accuracy NDIR Sensors NO˺ SO˺ H˺S VOC CO˺ NEW Display Screen & Keypad NEW Software with Automatic Data Logging Direct CO˺ Measurement to 50% y 2000 Tests) ents creen & Keypad nt to 50% CxHy(HC) NEW Display Screen & Keypad Design with Easy Filter Replacement NEW REAL-TIME Software Package with Automatic Data Logging REA NEW PID VOC Sensor OptionNEW (NDIR) True SO˺ & Low SO˺ Measurements Sample Conditionniinng UUnnit For Looww NNOOx & SO2 Backlit Display with Zoom Function
  • 21. E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind E8500 PLUS The updated “EGAS” software package includes the ability to save & graph data in real-time in the field with a laptop or in a laboratory with a PC. It also allows the user to automatically log data for an exact number of tests for a specified time period. Communications between the E8500 PLUS and a computer are established either by wireless Bluetooth communications or USB cable. A Bluetooth wireless adapter for a computer comes standard with each E8500 PLUS gas analyzer. Data from the “EGAS” software can be exported to other spreadsheet programs for more user flexibility to create detailed emissions reports. Real-Time Software with Data Logging EGAS Software The internal thermoelectric chiller efficiently and quickly removes the water vapor from the flue gas sample to prevent combustion gases from bubbling from the gas phase into the condensate. The built-in condensate drain pump automatically pumps the accumulated water out through the bottom of the unit for greater convenience. Built-In Thermoelectric Chiller with Auto Condensate Drain 40”(1m) & 60”(1.5m) High Temperature Probeshh Temperature Prob 40”(1m) & 600”(1 5m) Sintered Filter
  • 22. E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind ϴϱϬϬ Wh^ ^ƉĞĐŝĮĐĂƟŽŶƐ The E8500 PLUS has a newly designed user interface that includes an easily accessible filter compartment for quick and simple inspection replacement of filters in the field. Easy Filter Replacement The E8500 PLUS can have a maximum of nine total gas sensors; up to six electrochemical type sensors, up to three NDIR type sensors, and an optional PID sensor for measuring VOC. Gas Sensors An internal pressure sensor allows the analyzer to measure both pressure and stack draft. With two pressure inputs, differential pressure can also be measured. Gas velocity can be measured using the differential pressure and an optional Pitot tube. Draft, Pressure, Velocity Parameter Sensor Range Res. Accuracy O CO CO NO NO Pressure/Draft Excess Air Gas Velocity Efficiency 2 x ppm=±4% up to 5000 ppm=±4% 1.00 - infinity Electrochemical up to 2000 ppm=±4% 2000 ppm=±10% NDIR Electrochemical up to 5000 up to 1000 ppm=±4% up to 500 ppm=±4% 14.0 - 212.0°F 32.0 - 1830°F 32.0 - 1830°F Calculated Calculated Calculated Auto Range CO NO Low NO Low NO SO CO CO C H H S VOC Tair Tgas 2 2 2 2 2 x y 2 'T 0 - 8000 ppm 1 ppm 300 ppm=±8 ppm 0.01% ±0.1% vol0 - 25%Electrochemical ±10% rdg.1 ppm0 - 20,000 ppmElectrochemical 0 - 15.00% 0.01% ±3% rdg. 0 - 5000 ppm 1 ppm 1 ppm 125 ppm=±5 ppm Electrochemical 0 - 1000 ppm 125 ppm=±5 ppm up to 100.0 ppm=±4% 0 - 100.0 ppm 0.1 ppmElectrochemical 50.0 ppm=±1.5 ppm Calculated 0 - 5000 ppm 1 ppm 0 - 5000 ppmElectrochemical 125 ppm=±5 ppm 1 ppm Calculated 0 - 99.9% 0.1% 0 - 50.0% 0 - 3.00% 0.1% 0.01% ±3% rdg. + 0.01% ±3% rdg. 20% NDIR NDIR Electrochemical 0 - 500 ppm 1 ppm 125 ppm=±5 ppm PID 0 - 200 ppm 1 ppm ±10 % rdg. + 1 ppm Calculated Pt100 -10 - 99.9°C 1°C 1°F ±2°C ±3°F Tc K 0 - 999.9°C 0.1°C ±3°C 0.1°F ±5°F 0 - 999.9°C 1°F 1°C Bridge ± 40.0 in H O 0.1 in H O ±1% rdg. 0.01 0 - 99.9 m/s 0 - 330 ft/s 0.1 m/s 0.1 ft/s 1 - 99.9% 0.1% 2 2 0 - 100.0 ppm 0.1 ppmElectrochemicalLow SO 0 - 100.0 ppm 0.1 ppmElectrochemical 2 up to 100.0 ppm=±4% 50.0 ppm=±1.5 ppm up to 100.0 ppm=±4% 50.0 ppm=±1.5 ppm The Sample Conditioning Unit is mounted directly at the sampling probe exit, where excess moisture rapidly condenses and separates from the gas sample. This minimizes contact of the gases with moisture, which could potentially affect NOx and SO2 measurements. Sample Conditioning Unit ±5% rdg. 20%
  • 23. E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind E8500 PLUS E8500 PLUS Ordering Code Part # 8500P - Table A - Table B - Table C Table C - Sampling Probes and Hoses 12 12” (300mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose 30 40 60 30” (750mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose 40” (1m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for High Temperature Combustion Applications 60” (1.5m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for High Temperature Combustion Applications Table B - NDIR (non-dispersive infrared) Sensors ABC CO Sensor (0 - 50 %), CxHy Sensor (0 - 3 %), High CO Sensor (0 - 15 %)2 and 0 No NDIR sensors Standard E8500 PLUS Configuration (E8500P-OCN-0-12) Includes: - O2, CO, and NO Gas Sensors - Thermoelectric Chiller with Automatic Condensate Drain Pump - Rechargeable Battery Pack - 110-240VAC/50-60Hz Battery Charger - 12”/300mm Probe with 10’/3m Dual Hose - Stack Gas Air Temperature Measurements - Draft Differential Pressure Measurements - Calculated Values for Efficiency, Excess Air, CO % - Internal Memory (2,000 Tests) - Real-Time Software Package with Bluetooth Module - Wireless Bluetooth Communications - Protective Carrying Case - Calibration Certificate - Operations Manual 2 Weight: 11 lbs. (5 kg) Dimensions: 10x6x9.5” (26x15x24 cm) mp Bulletin:E8500PLUS.2Ed.01/2017Informationdesignsubjecttochangeatthemanufacturer’sdiscretion Table A - Electrochemical Sensors O C N D S H O Sensor (0 - 25 %) CO Sensor (0 - 8000 ppm) with Dilution Auto-Range up to 20,000 ppm NO Sensor (0 - 5000 ppm) NO Sensor (0 - 1000 ppm) SO Sensor (0 - 5000 ppm) H S Sensor (0 - 500 ppm) 2 2 2 2 V VOC Sensor (0 - 200 ppm)** *H S VOC sensors cannot concurrently be installed on one E8500 PLUS2 **Must include NDIR sensor option to include VOC sensor
  • 24. Portable Industrial Flue Gas Emissions Analyzer Portable Emissions Analyzer with Temperature Controlled NOx Measurement for Boiler, Engine, Furnace, and other Combustion Applications E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind E8500 Cooled NOx Built-In Thermoelectric Cooler for NO Sensor Up to 9 Total Gas Sensors MADE IN USA CO Dilution Auto-Range Long Life Rechargeable Battery Upgraded Memory (2000 Tests) True NOx Low NOx Measurements NEW Display Screen Keypad NEW Software with Automatic Data Logging Direct CO˺ Measurement to 50% USAMADE IN UUS NEW Cooled NO Sensor to Optimize Accuracy of NOx Measurements NEW A Displays Records the Temperature at the Cooled NO Sensor DispDisp CO O˺ NO˺ SO˺ H˺S VOC CxHy CO˺(NDIR) NEW PID VOC Sensor Option NOx NO(Cooled)
  • 25. E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind E8500 Cooled NOx The updated “EGAS” software package includes the ability to save graph data in real-time in the field with a laptop or in a laboratory with a PC. It also allows the user to automatically log data for an exact number of tests for a specified time period. Communications between the E8500 Cooled NOx and a computer are established either by wireless Bluetooth communications or USB cable. A Bluetooth wireless adapter for a computer comes standard with each E8500 Cooled NOx gas analyzer. Data from the “EGAS” software can be exported to other spreadsheet programs for more user flexibility to create detailed emissions reports. Real-Time Software with Data Logging EGAS Software The accuracy of the gas sensor for NO, the primary component of NOx, can be compromised when exposed to ambient temperatures above 86°F (30°C) and significantly more so above 104°F (40°C). To help prevent this temperature effect on the NO sensor, the E8500 Cooled NOx keeps the NO sensor cooled with an internal cooling system. The analyzer measures, displays, records the NO sensor temperature to make it easier to comply with US EPA conditional test methods such as CTM-030. Cooled NO Sensor for Optimal Accuracy Sintered Filter 40”(1m) 60”(1.5m) High Temperature Probes
  • 26. E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind ϴϱϬϬ ŽŽůĞĚ EKdž ^ƉĞĐŝĮĐĂƟŽŶƐ The E8500 Cooled NOx has a newly designed user interface that includes an easily accessible filter compartment for quick and easy inspection replacement of filters in the field. Easy Filter Replacement The E8500 Cooled NOx can have a maximum of nine total gas sensors; up to six electrochemical type sensors, up to three NDIR type sensors, and an optional PID sensor for measuring VOC. Gas Sensors An internal pressure sensor allows the analyzer to measure both pressure and stack draft. With two pressure inputs, differential pressure can also be measured. Gas velocity can be measured using the differential pressure and an optional Pitot tube. Draft, Pressure, Velocity Parameter Sensor Range Res. Accuracy O CO CO NO NO Pressure/Draft Excess Air Gas Velocity Efficiency 2 x ppm=±4% up to 5000 ppm=±4% 1.00 - infinity Electrochemical up to 2000 ppm=±4% 2000 ppm=±10% NDIR Electrochemical up to 5000 up to 1000 ppm=±4% up to 500 ppm=±4% 14.0 - 212.0°F 32.0 - 1830°F 32.0 - 1830°F Calculated Calculated Calculated Auto Range CO NO Low NO Low NO SO CO CO C H H S VOC Tair Tgas 2 2 2 2 2 x y 2 'T 0 - 8000 ppm 1 ppm 300 ppm=±8 ppm 0.01% ±0.1% vol0 - 25%Electrochemical ±10% rdg.1 ppm0 - 20,000 ppmElectrochemical 0 - 15.00% 0.01% ±3% rdg. 0 - 5000 ppm 1 ppm 1 ppm 125 ppm=±5 ppm Electrochemical 0 - 1000 ppm 125 ppm=±5 ppm up to 100.0 ppm=±4% 0 - 100.0 ppm 0.1 ppmElectrochemical 50.0 ppm=±1.5 ppm Calculated 0 - 5000 ppm 1 ppm 0 - 5000 ppmElectrochemical 125 ppm=±5 ppm 1 ppm Calculated 0 - 99.9% 0.1% 0 - 50.0% 0 - 3.00% 0.1% 0.01% ±3% rdg. + 0.01% ±3% rdg. 20% NDIR NDIR Electrochemical 0 - 500 ppm 1 ppm 125 ppm=±5 ppm PID 0 - 200 ppm 1 ppm ±10 % rdg. + 1 ppm Calculated Pt100 -10 - 99.9°C 1°C 1°F ±2°C ±3°F Tc K 0 - 999.9°C 0.1°C ±3°C 0.1°F ±5°F 0 - 999.9°C 1°F 1°C Bridge ± 40.0 in H O 0.1 in H O ±1% rdg. 0.01 0 - 99.9 m/s 0 - 330 ft/s 0.1 m/s 0.1 ft/s 1 - 99.9% 0.1% 2 2 0 - 100.0 ppm 0.1 ppmElectrochemicalLow SO 0 - 100.0 ppm 0.1 ppmElectrochemical 2 up to 100.0 ppm=±4% 50.0 ppm=±1.5 ppm up to 100.0 ppm=±4% 50.0 ppm=±1.5 ppm The Sample Conditioning Unit is mounted directly at the sampling probe exit, where excess moisture rapidly condenses and separates from the gas sample. This minimizes contact of the gases with moisture, which could potentially affect NOx and SO2 measurements. Sample Conditioning Unit ±5% rdg. 20%
  • 27. E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind E8500 Cooled NOx E8500 Cooled NOx Ordering Code Part # 8500CN - Table A - Table B - Table C Table C - Sampling Probes and Hoses 12 12” (300mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose 30 40 60 30” (750mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose 40” (1m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for High Temperature Combustion Applications 60” (1.5m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for High Temperature Combustion Applications Table B - NDIR (non-dispersive infrared) Sensors ABC CO Sensor (0 - 50 %), CxHy Sensor (0 - 3 %), High CO Sensor (0 - 15 %)2 and 0 No NDIR sensors Standard E8500 Cooled NOx Configuration (E8500CN-OCN-0-12) Includes: - - - Rechargeable Battery Pack - 110-240VAC/50-60Hz Battery Charger - 12”/300mm Probe with 10’/3m Dual Hose - Stack Gas Air Temperature Measurements - Draft Differential Pressure Measurements - Calculated Values for Efficiency, Excess Air, CO % - Internal Memory (2,000 Tests) - Real-Time Software Package with Bluetooth Module - Wireless Bluetooth Communications - Protective Carrying Case - Calibration Certificate - 2 Weight: 11 lbs. (5 kg) Dimensions: 10x6x9.5” (26x15x24 cm) T Bulletin:E8500CooledNOx.1Ed.03/2017Informationdesignsubjecttochangeatthemanufacturer’sdiscretion Table A - Electrochemical Sensors O C N D S H O Sensor (0 - 25 %) CO Sensor (0 - 8000 ppm) with Dilution Auto-Range up to 20,000 ppm NO Sensor (0 - 5000 ppm) NO Sensor (0 - 1000 ppm) SO Sensor (0 - 5000 ppm) H S Sensor (0 - 500 ppm) 2 2 2 2 V VOC Sensor (0 - 200 ppm)** *H S VOC sensors cannot concurrently be installed on one E8500 Cooled NOx2 **Must include NDIR sensor option to include VOC sensor - - NL Low NO Sensor (0 - 100.0 ppm) DL Low NO Sensor (0 - 100.0 ppm)2 - NO Sensor Temperature Measurement Operations Manual External Water Trap with Filter Thermoelectric Cooler for NO Sensor O2, CO, and NO Gas Sensors Sample Conditioning Unit
  • 28. Portable Industrial Flue Gas Emissions Analyzer Transportable Emissions Analyzer for Boiler, Engine, Furnace, Kiln, and other Combustion Applications CO O˺ E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind NO E9000 Built-In Thermoelectric Chiller Up to 9 Total Gas Sensors CO Dilution Auto-Range Automatic Condensate Drain Pre-Calibrated Gas Sensors Upgraded Memory (16,000 Tests) True NOx Low NOx Measurements High Accuracy NDIR Sensors Including CO˺ Sensor to 50% NO˺ SO˺ H˺S Low NOx CO˺ Color Graphic Display Software with Automatic Data Logging Built-In Printer CxHy(HC) Heated Probe Head Sample HoseHea Software Package with Automatic Data Logging Soft (NDIR) Android App to Monitor Save Data lt-In Thermoelectric Chiller ge tic Condensate Drain rs emory (16,000 Tests) ments s % isplay Software US EPA CTM-030 CTM-034 Compliant Customize to Meet Your Em issio ns Monitoring Requirem ents Heavy Duty Case
  • 29. E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind E9000 Specifications Heated Sample Hose Probe Head The E9000 has an optional heated probe head and flexible heated sample line. This feature maintains the sample gas at a temperature higher than the dew point to prevent condensation from occurring before the stack gas reaches the internal thermoelectric chiller. The water vapor condenses very rapidly at the chiller so the gases do not have ample opportunity time to dissolve into the condensate. This sample conditioning system maintains the integrity of the gas composition especially for the most water soluble gases such as NO˺ and SO˺. The large multi-color graphic display screen includes a zoom function. The capacitive touch sensing keypad guides the operator through the user friendly menus on the display screen. The measured calculated parameters on the display screen can be fully customized as the operator requires. The internal printer is included with each E9000 and prints on a special non-fading polymer paper so it can still be easily read even when exposed to water, heat, or light. As with the display screen, the parameters on the print-out can be customized by each operator. Each E9000 includes an internal high efficiency Peltier thermoelectric chiller with a built-in condensate drain pump that automatically pumps the accumulated water out through the bottom of the unit for greater convenience. Along with the optional heated sample hose probe head, this sample conditioning system allows for longer test periods while maximizing the integrity and composition of the sampled stack gas so the gases measured by the analyzer are representative of the actual stack/flue gases. Superior Sample Conditioning for Semi-Continuous Use Display Screen Keypad Built-In Printer
  • 30. E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind E9000 Specifications Parameter Sensor Range Res. Accuracy O CO CO NO NO 2 x ppm=±4% up to 5000 ppm=±4% Electrochemical up to 2000 ppm=±4% 2000 ppm=±10% NDIR Electrochemical up to 5000 up to 1000 ppm=±4% up to 500 ppm=±4% Auto Range CO NO Low NO Low NO SO CO CO C H H S 2 2 2 2 2 x y 2 0 - 8000 ppm 1 ppm 200 ppm=±5 ppm 0.1% ±0.1% vol0 - 25%Electrochemical ±10% rdg.0.01%0 - 10.00%Electrochemical 0 - 15.00% 0.01% ±3% rdg. 0 - 5000 ppm 1 ppm 1 ppm 125 ppm=±5 ppm Electrochemical 0 - 1000 ppm 125 ppm=±5 ppm up to 100.0 ppm=±4% 0 - 100.0 ppm 0.1 ppmElectrochemical 50.0 ppm=±1.5 ppm Calculated 0 - 5000 ppm 1 ppm 0 - 5000 ppmElectrochemical 125 ppm=±5 ppm 1 ppm Calculated 0 - 99.9% 0.1% 0 - 50.0% 0 - 50,000 ppm 0.1% 1 ppm NDIR NDIR Electrochemical 0 - 500 ppm 0.1 ppm 125 ppm=±5 ppm Pellistor 0 - 5.00% 0.01% ±5 % Full Scale 0 - 100.0 ppm 0.1 ppmElectrochemicalLow SO 0 - 100.0 ppm 0.1 ppmElectrochemical 2 up to 100.0 ppm=±4% 50.0 ppm=±1.5 ppm up to 100.0 ppm=±4% 50.0 ppm=±1.5 ppm C Hx y up to 50,000 ppm=±2% 1000 ppm=±50 ppm up to 50%=±5% rdg. 8%=±3% rdg.
  • 31. E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind E9000 Table C - Sampling Probes and Hoses 12 12” (300mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose 30 40 60 30” (750mm) Probe, 1470°F (800°C) max, with 10’ (3m) Dual Hose 40” (1m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for High Temperature Combustion Applications 60” (1.5m) Probe, 2190°F (1200°C) max, with 10’ (3m) Hose for High Temperature Combustion Applications Table B - NDIR (non-dispersive infrared) Sensors IR CO Sensor (0 - 50 %), CxHy Sensor (0 - 5 %), High CO Sensor (0 - 15 %)2 and 0 No NDIR sensors Standard E9000 Configuration (E9000-OCN-0-12) Includes: - O2, CO, and NO Gas Sensors, Upgradeable to 9 Gas Sensors Total - Thermoelectric Chiller with Automatic Condensate Drain Pump - Rechargeable Battery Pack - 110-240VAC/50-60Hz Battery Charger - 12”/300mm Probe with 10’/3m Dual Hose - Stack Gas Air Temperature Measurements - Draft Differential Pressure Measurements - Calculated Values for Efficiency, Excess Air, CO % - Internal Memory (16,000 Tests) - Software Package with USB Bluetooth Interface - Wireless Bluetooth Communications - Heavy Duty Aluminum Carrying Case - Calibration Certificate - Operations Manual 2 Weight: 29 lbs. (13 kg) Dimensions: 20x14x8” (50x36x20 cm) -12) Includeses: Sensors Totalal Pump Bulletin:E9000.1Ed.6/2016Informationdesignsubjecttochangeatthemanufacturer’sdiscretion E9000 Ordering Code Part # 9000 - Table A - Table B - Table C Table A - Electrochemical Sensors (Maximum of Six) O C N D S H O Sensor (0 - 25 %) CO Sensor (0 - 8000 ppm) with Dilution Auto-Range up to 10% NO Sensor (0 - 5000 ppm) NO Sensor (0 - 1000 ppm) SO Sensor (0 - 5000 ppm) H S Sensor (0 - 500 ppm) 2 2 2 2 NL Low NO Sensor (0 - 100.0 ppm) DL Low NO Sensor (0 - 100.0 ppm) SL Low SO Sensor (0 - 100.0 ppm)2 2 12” (300mm) Probe, 1470°F (800°C) max, with 10’ (3m) Heated Sample Hose Probe Head 12H 40” (1m) Probe, 2190°F (1200°C) max, with 10’ (3m) Heated Sample Hose Probe Head 40H SINT1 Sintered Filter with Half Shield for Probe Tip ( ) p
  • 32. Application Notes Emissions Monitoring E Instruments is Proud to Offer A Wide Variety of In-Depth Application Notes to its Customers Such As: MARPOL ANNEX VI Compliance Using a Portable Emissions Analyzer Application Note # IA-14-0701 Flexibility Versatility of a Portable Emissions AnalyzerApplication Note # IA-13-0501 Mining Using Portable Emissions Analyzers for Optimizing the Performance of a Cogeneration Plant Application Note # IA-13-0801 Cogeneration Forklifts Marine Power Generation Engines Industrial Boilers For a Complete List of Our Application Notes Please Visit Our Website at www.E-Inst.com Refineries Cement Incinerators
  • 33. Application Notes Combustion Analysis E Instruments is Proud to Offer A Wide Variety of In-Depth Application Notes to its Customers Such As: Why Use NOx Filters on CO Sensors?Application Note # HV-16-0915 The Importance of Combustible Gas Leak DetectionApplication Note # HV-13-0516 Boilers Measuring Combustion Efficiency on Atmospheric Boilers Furnaces Application Note # HV-13-0717 Technical Schools Burners For a Complete List of Our Application Notes Please Visit Our Website at www.E-Inst.com Furnaces Heaters Weatherization Research Development Energy Auditing Controls Building Inspection Facilities
  • 34.
  • 35. Gas Sampling Probes Accessories 12(300mm) Standard Probe (gas draft), 1470F(800C) max, with 10'(3m) dual hose 30(750mm) Probe (gas draft), 1470F(800C) max, with 10'(3m) dual hose Sintered Filter with Half-Shield for End of Probe (compatible with 40 60 Probes only) for High Dust, Particle, Ash Applications 36 (900mm) Pitot Tube for Measurements Calculations of: Standard Probes Sintered Filter Pitot Tube ˒ Stack/Flue Gas Velocity ˒ Coal Fired Boilers ˒ Cement Kilns ˒ Volumetric Flow Rate ˒ Mass Emissions ˒ Steel Furnaces ˒ Incinerators ˒ Boilers ˒ Burners ˒ Heaters ˒ Engines Applications: Applications: 40 (1m) Probe, 2190F (1200C) max, with 10' (3m) Hose 60 (1.5m) Probe, 2190F (1200C) max, with 10' (3m) Hose Longer High Temperature Probes ˒ Cement ˒ Power Plants obes ˒ Steel ˒ Glass Applications: * Customized Probes available up to 100” (2.5m) in length available upon request Sample Conditioning Unit ˒ High Moisture Flue Gases ˒ ĵŸɠ ŗŷɮ ˓ ĵŸɠ Ǣŷ˺ Measurements Applications: Removes moisture at probe handle to maintain the integrity of the sampled flue gas. Available with all gas analyzers.
  • 36. Built With Quality In Mind ‡ Automobiles ‡ Forklifts ‡ Trucks ‡ Buses ‡ Burnishers ‡ Loaders ‡ Excavators ‡ Tractors ‡ Motorcycles Applications Relevant Markets ‡ Material Handling ‡ Automotive Maintenance ‡ Transpotation Shipping ‡ Fleet Maintenance ‡ Mining ‡ Fuel Additives ‡ Engine Catalysts ‡ Construction ‡ Combustion Research Automotive Emissions Product Line
  • 37. Automotive Emissions Analyzers F900 O2 CO F5000 O2, CO, NO, CxHy 7899 Hydrocarbon Detector
  • 38. O2Robust Fast Reliable Accurate E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind N Forklift Small Engine Exhaust Gas Analyzer Pre-Compliance VerificationPre- CO Safety TestingCO S Engine Tuning MaintenanceEngi CO Traceable Calibration Certificate Optional Wireless Bluetooth™ Printer Oxygen (O2)Measurement Internal Memory (2,000 Tests) Measure CO Up to 50,000 ppm (5%) Sampling Probe S-Type Exhaust Fitting Real-Time Data Logging Software g yp h Ideal For: Automatic Data Saving Feature Protective Magnetic Boot MADE IN USA
  • 39. Built with Quality in Mind Ordering Information Model No. Description F900 F900-P Base Kit = CO Sensor, 2,000 Internal Test Memory, PC Software, Bluetooth™, Exhaust Sampling Probe Base Kit w/ Printer = CO Sensor, 2,000 Internal Test Memory, PC Software, Bluetooth™, Exhaust Sampling Probe + Wireless Bluetooth™ Printer E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com ˒ CO Sensor (0 to 50,000 ppm, 5%) ˒ Option for O2 Sensor ˒ 2,000 Test Internal Memory ˒ Bluetooth Connectivity ˒ Rechargeable Battery AC Charger ˒ ˠˡˇ Gas Sampling Probe Hose ˒ ŷƼǼÞŸŘ ¯ŸNj Ǣ˚ǻɴƼs ƻNjŸEs ®ÞǼǼÞŘض ˒ ŷƼǼÞŸŘ ¯ŸNj ®ĶsɮÞEĶs ƻNjŸEs ǻÞƼ ˒ Water Trap with Filter Cartridge ˒ Magnetic Rubber Holster ˒ PC Software USB Cable ˒ Operating Manual ˒ Calibration Certification ˒ Vinyl Carrying Case ˒ ŷƼǼÞŸŘ ¯ŸNj ɟÞNjsĶsǣǣ Bluetooth™ Printer All F900 Kits Include: S-Type Probe Fitting w/ Exhaust Clamp Flexible Tip Optional Wireless Bluetooth™ Printer NEW!! PC Software Wireless Bluetooth High Range CO Sensor (0 - 50,000 ppm, 5%) Internal Memory Automatic Data Saving Gas Sampling Probe Magnetic Boot Applications Parameter Sensor ResolutionRange Accuracy ŷ˺ CO Electrochemical Electrochemical 0 - 25% 0 - 50,000 ppm (0 - 5 %) ˟ʳˠ̇ ˠ ƼƼŎ ±0.2% vol ±8 ppm 300 ppm ±4% rdg up to 4000 ppm ̝ˠ˟̇ Nj_¶ ̤ˣ˟˟˟ ƼƼŎ Technical Specifications Hands Free Operation Durable Design Forklifts Propane Burnishers Polishers Other Small Engines Propane Grinders Bulletin:F900.3Ed.01/2017Informationdesignsubjecttochangeatmanufacture’sdiscretion nical Specificat PC Software with Real-Time Automatic Data Logging Save, Graph, Export Data Wirelessly via Bluetooth S-Type P w/ Exhaust Clamp Flexible Tip sly
  • 40. E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com Automotive Forklift Exhaust Gas Analyzer Pre-Compliance VerificationPre- Vehicle DiagnosticsVehi Engine Tuning MaintenanceEngi Applications: Built with Quality in Mind Flexible Exhaust Probe Tip Sampling Probe with S-Type Exhaust Fitting Real-Time Data Logging Software Wireless Bluetooth™ Printer High Accuracy NDIR Sensors: CO, CO2, HC For Propane, Diesel, LPG, CNG, Gasoline Engines CO HC CO2 NOxO2 AFR Lambda (ʭ)
  • 41. Built with Quality in Mind E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 www.E-Inst.com ˒ CO2 Sensor ˒ CO Sensor ˒ HC Sensor ˒ O2 Sensor ˒ NO/NOx Sensor ˒ Internal Memory (2000 Tests) ˒ Bluetooth Connectivity ˒ Rechargeable Battery Charger ˒ ˠˡˇˀˢ˟˟ŎŎ Sampling Probe ˠ˟˅ˀˢŎ Ǣ ŎƼĶÞض ËŸǣs ˒ S-Type Exhaust Fitting w/ Clamp ˒ Sample Conditioning Unit (SCU) For Condensation Removal ˒ PC Software USB Cable ˒ Operating Manual ˒ Calibration Certificate ˒ ŷƼǼÞŸŘ ¯ŸNj ɟÞNjsĶsǣǣ Bluetooth™ Printer ˒ ŷƼǼÞŸŘ ¯ŸNj ®ĶsɮÞEĶs Probe Attachment ˒ ŷƼǼÞŸŘ ¯ŸNj ƻNjŸǼsOǼÞɚs N NjNjɴÞض N ǣs F5000-5GAS Includes: Optional Wireless Bluetooth™ Printer Applications Bulletin:F5000.3Ed.01/2017Informationdesignsubjecttochangeatmanufacture’sdiscretion ndBuilt with Quality in Min Flexible Probe Tip PC Software with Real-Time Automatic Data Logging Technical SpecificationsTe Parameter Sensor ResolutionRange Accuracy CO NDIR ˟˚ˠˤ ̇ ˟ʳ˟ˠ ̇ ˟ʳ˟ˡ̇ ̝ˢ̇ Nj_¶ʳ NDIR ˟˚ˡ˟ ̇ ˟ʳˠ ̇ ˟ʳˠ̇ ̝ˢ̇ Nj_¶ʳNŷ˺ HC NDIR ˟ ˚ ˠ˟ʰ˟˟˟ ƼƼŎ ˠ ƼƼŎ ŷ˺ Electrochemical ˟ ˚ ˡˤ̇ ˟ʳˠ̇ ̝˟ʳˠ̇ ɚŸĶ NO/NOx Electrochemical ˟ ˚ ˤʰ˟˟˟ ƼƼŎ ˠ ƼƼŎ ̣ˠˡˤ ƼƼŎ̠̝ˤ ƼƼŎ ȖƼ ǼŸ ˤʰ˟˟˟ ƼƼŎ̠̝ˣ̇ Light Weight, Portable, Durable Printed Digital Emissions Reports Rechargeable, Long Life Battery Vehicles Trucks Buses Forklifts MADE IN USA Swivel Handle For Easy Operation Transport S-Type Probe Fitting Exhaust Clamp ̝ˢ̇ Nj_¶ʳ ʹˢ˟ˠ˚ˣʰ˟˟˟ ƼƼŎʺ ̝˧ ƼƼŎ ʹ˟˚ˢ˟˟ ƼƼŎʺ ̝ˤ̇ Nj_¶ʳ ʹˣʰ˟˟ˠ˚ˠ˟ʰ˟˟˟ ƼƼŎʺ
  • 42. Economical Accurate Combustible Hydrocarbon Gas Detector for Automotive, Small Engines, and Forklifts Hydrocarbon Gas Detector Model 7899 Propane Propane Propane 2 0.0 - 5,500 ppm
  • 43. Automotive Emissions Sampling Probes Accessories 12(300mm) Exhaust Gas Sampling Probe with 10'(3m) hose Standard Probe 12(300mm) Exhaust Gas Sampling Probe with S-Type Fitting, Exhaust Clamp, 10'(3m) hose Standard Probe with S-Type Fitting 12(300mm) Exhaust Gas Sampling Probe with Sample Conditioning Unit (SCU), S-Type Fitting, Exhaust Clamp, 10'(3m) hose Automotive Probe Flexible Extension for Probes Installed with an S-Type Fitting Flexible Tip Extension Wireless Bluetooth Printer Sampling Prob lamp, 10'(3m) hose Probes Installed with an S-Type Fitting Wireless Bluetooth Printer for On-Site Emissions Reports (Comes With SCU)
  • 44. Built With Quality In Mind Product Line Markets Applications ‡ Architects Building Developers ‡ Research Development ‡ Manufacturing Facilities ‡ Research Laboratories ‡ Greenhouse Buildings ‡ Hospitals Medical ‡ Building Inspectors ‡ LEED Certification ‡ Industrial Hygiene ‡ Building Hygiene ‡ Energy Auditing ‡ Weatherization ‡ VOC Testing ‡ Warehouses ‡ Universities ‡ Incubators ‡ Airports IAQ
  • 45. Indoor Air Quality Monitors AQ PRO AQ Incuba AQ VOC AQ Comfort AQ Expert NONNNNNNNOOOOOOO CH O2 CO2CCCCCOOOOOOOO22222222 SSSSSSS2H COCCCCCCCCCOOOOOOOO % RHRRRRRRHHHHHHHH%%%% RRRRRRRR NO2NNNNNNNOOOOOOO222222222 SO2 O2 VOC O3
  • 46. Protective Magnetic Rubber Boot Handheld Indoor Air Quality Monitor PC Software USB Cable E Instruments International www.E-Inst.com P: 215-750-1212 Wireless Communications with Computer Remote Printer Light Weight, Durable, Handheld Design F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 CO2 The Latest in Indoor Air Quality Monitoring Real-Time Data-Logging for IAQ Analysis in Homes, Schools, Offices, and much more Real-Time Data-Logging for Graphs, Data Review, IAQ Reports “Built with Quality in Mind” Temp. % RH Optional Handheld Probe Temp. Differential Optional Wireless Printer AQ ComfortAQ Comfort CO Add Safety- Long Lasting Rechargeable Battery Easy to Use Menu System Large Internal Memory (2000) Innovative IAQ Tool for HVAC Professionals REAL-TIME Continuous Data-Logging Provide your own Comfort Audit ™ Active Internal Sampling Pump Compact Handheld Unit Dew Point Differential Pressure Wet Bulb Accessories: MADE IN USA
  • 47. P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 E Instruments International www.E-Inst.com Applications Distributed By: Bulletin:AQCOMFORT.1Ed.10/2016Informationdesignsubjecttochangeatthemanufacture’sdiscretion.’ (Optional) AQ Gas Real-time Datalogging Software ® CO % RH CO2 ALL AQ Comfort Kits Include: Ɣ Continuous Active Internal Sampling Pump Ɣ Differential Pressure Ɣ Operating Manual Ɣ Long Lasting Battery AC Charger Ɣ Factory Calibration Certificate Ɣ Differential Temperature AQ ComfortAAQQQ ComfortComfortComfort Temp ¨P Temp. CO Relative Humidity Ambient CO2 Temperature Type K T1 Differential Pressure Specifications Parameter Sensor Range Res. Accuracy 0 - 200 ppm 0.1 ppm ± 1% rdg. ± 0.2 ppmElectrochemical NDIR 0 - 5,000 ppm 1 ppm 0.1°C/F Tc K (0 - 1100°C) 0.1%TFC Bridge ± 8.0 inH O ± 1% rdg.2 (±20.0 mbar) (0.25 mbar) (-40 - 125°C) Electomagnetic Compatibility EN 61326-1, Portable Equipment Temperature CO Features AQ Comfort ORDERING CODE AQ Comfort Kit CO2 Bluetooth AmbientTemp %RH, Wet Bulb Dew Point Carrying Case Ŷ Kit-1 Kit-2 Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ Kit-3 Kit-4 Internal Memory (2000) PC Software Kit ŶŶ -40 - 257°F Pt100 20.1 inH O 5°F (3°C) or 2% of rdg1°C/F 0 - 2000°F 5 - 95% ± 0.4°C (0 - 60°C) ± 2% RH ± 2% rdg. ± 10 ppm
  • 48. PC Software USB Included Long Lasting Rechargeable Battery Barometric Air Pressure Protective Magnetic Rubber Boot Large Internal Memory (2000) Handheld Indoor Air Quality Monitor E Instruments International www.E-Inst.com P: 215-750-1212 Wireless Communications with Computer Remote Printer Light Weight, Durable, Handheld Design F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 CO CO 2 Customize UP to 3 Gases The Latest in Indoor Air Quality Monitoring Real-Time Data-Logging for IAQ Analysis in Hospitals, Universities, Labs, Airports, and more Graphs, Data Review, IAQ reports AQ PRO REAL-TIME Continuous Data-Logging Active Internal Sampling Pump “Built with Quality in Mind” H S2 NO2 SO2 Temp AAQQQ OPROPRO % RH Compact Handheld Unit O2 Optional Handheld Probe Barometric Pressure Formaldehyde NO Optional Wireless Printer MADE IN USA Real-Time Data-Logging for attery oot a-LLoooogging mp (Multiple Parameters - Up to 6 Total)
  • 49. P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 E Instruments International www.E-Inst.com AQ PROAQ PRO Relative Humidity Temp. Ambient Barometric Pressure Pressure Temperature Type K T1 Differential Specifications Parameter Sensor Range Res. Accuracy Pt100 -40 - 257°F 0.1°C/F ± 0.4°C (0 - 60°C) Solid State Tc K 0 - 2000°F 1°C/F ± 2% of rdg (0 - 1100°C) 5 - 95% RH 0.1% RH ± 2% RHTFC Bridge ± 8.0 inH O 0.1 inH O ±1% of rdg.2 2 Distributed By: NO2 SO2 O2 CO H2S % RH CO2 CH O2 Bulletin:AQPRO.5Ed.01/2017Informationdesignsubjecttochangeatthemanufacture’sdiscretion.’ AQ Gas Real-Time Datalogging Software 260 - 1260 mbar 1 mbar ± 2 mbar NNNNNNNOOOOOOOO222222222 OOOOOOOOO2222222 CCCCCCCCOOOOOOOO SSSSSSOOOOOO22222SS %%%% RRRRRRRHHHHHHH%%%% HHHHHHH2222222SSSSS CCCCHHHHHHH OOOOOOOO22222 OO CCCCCOOOOOOO2222222 (±20.0 mbar) (0.25 mbar) (-40 - 125°C) Electomagnetic Compatibility EN 61326-1, Portable Equipment Operating Manual Quick Reference Guide ALL AQ PRO Kits Include: Temperature, % Relative Humidity Continuous Active Internal Sampling Pump Differential Pressure Long Lasting Battery AC Charger Factory Calibration Certificate AQ PRO ORDERING CODE Barometric Pressure PC Software USB Cable Bluetooth Connectivity Protective Carrying Case Select UP to ANY 3* Gases Below: Part #: PRO - ___ - ___ - ___ Optional Accessories Wireless Bluetooth™ Printer ories Example: Part #: PRO - C2 - C - H = CO2, CO, H2S Parameter Sensor Range Res. Accuracy O - Oxygen (O ) EC 0 - 25% 0.1 % ± 0.1% vol rdg.2 C2 - Carbon Dioxide (CO ) NDIR 0 - 5,000 ppm 1 ppm ± 2% of rdg. ± 10 ppm2 1 EC 0 - 20 ppmN - Nitrogen Dioxide (NO )2 EC 0 - 250 ppm 0.1 ppm ± 4% of rdg. ± 0.5 ppmX - Nitric Oxide (NO) 2 EC 0 - 20 ppm 0.1 ppm ± 4% of rdg. ± 0.5 ppm- Sulfur Dioxide (SO )2 1 H - Hydrogen Sulfide (H S) 0 - 100 ppm 1 ppm2 ±4% of rdg. ± 0.5 ppm C - Carbon Monoxide (CO) 0 - 200 ppm 0.1 ppm ± 4% of rdg. ± 0.5 ppm ® REAL-TIME Continuous Data-Logging F 0 - 10 ppm- Formaldehyde (CH O) ± 5% of rdg. ± 50 ppb (0 - 10,000 ppb) (EE900P) (E85AACSF13) Pitot Tube (BB610032) for Air Velocity Sampling Probe 0 - 300 ft/sec 1 ft/secAir Velocity Calculated ElectrochemicalOther Ranges are Available Upon Request Accuracy Based on Laboratory Conditions2.1. 3. This sensor may have interference from H2 , CO, H2S and other reducing gases such as alcohols4. 2,5 2,5 2,5 2,5 2,5 2,5 2,5 EC EC 1 3,4 EC 1 1 1 Maximum of TWO (2) Electrochemical (EC) Sensors Per Unit*5. (AQMET) Moisture Exchange Tube for Calibration ± 4% of rdg. ± 0.5 ppm0.1 ppm 1 ppb
  • 50. Portable Handheld VOC Monitor E Instruments International www.E-Inst.com P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 AQ VOC “Built with Quality in Mind” AAQQQ CVOCVOC Accurate VOC Monitoring Real-Time Data-Logging for Air Quality Analysis in Industrial Safety, Environmental, Laboratories and other IAQ Applications Wireless Communications with Computer Remote Printer Light Weight, Durable, Handheld Design Real-time Data-Logging Software for Graphs, Data Review, IAQ reports VOC Formaldehyde CO CO 2 H S2 NO2 SO2 Temp % RH O2 Barometric Pressure NO REAL-TIME Continuous Data-Logging Active Internal Sampling Pump Large Internal Memory (2000) PC Software USB Included Long Lasting Rechargeable Battery Barometric Air Pressure Protective Magnetic Rubber Boot Optional Wireless Printer Optional Handheld Probe Dynamic PID VOC Sensor Technology VOC in ppb/μg/m³ or ppm/mg/m³ UPGRADEABLE: (Add UP TO 2 More Gas Sensors) 0 - 20,000 PPB 0 - 200 PPM MADE IN USA a-Logging mp ) ttery ot m/mg/m³ ensors)
  • 51. EC P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 E Instruments International www.E-Inst.com AQ VOCAQ VOC Specifications Parameter Sensor Range Res. Accuracy Relative Humidity 5 - 95% RHTFC Distributed By: NO2 SO2 O2 CO H2S % RH Bulletin:AQPRO.2Ed.01/2017Informationdesignsubjecttochangeatthemanufacture’sdiscretion.’ AQ Gas Real-Time Datalogging Software SSSSSOOOOO222222 ® Barometric Pressure Solid State 260 - 1260 mbar 1 mbar NNNNNNNOOOOOOOO22222222 SS OOOOOOOOO2222222 CCCCCCCCOOOOOOOO %%%% RRRRRRRHHHHHHHH% HHHHHHH222222222SSSS CH O2 CCCCHHHHHH OOOOOOO22222 OO CO2CCCCCOOOOOO2222222 Temp. Ambient -40 - 257°F (-40 - 125°C) Electomagnetic Compatibility EN 61326-1, Portable Equipment Optional Accessories Wireless Bluetooth™ Printer Electrochemical EC 0 - 20 ppm- Sulfur Dioxide (SO ) EC ±4% of rdg. ± 0.5 ppmN - Nitrogen Dioxide (NO )2 X - Nitric Oxide (NO) EC 1 ppbF - Formaldehyde (CH O)2 ± 5% od rdg. ± 50 ppb 2 Other Ranges are Available Upon Request H - Hydrogen Sulfide (H S) EC 0 - 100 ppm 1 ppm2 ± 4% of rdg. ± 0.5 ppm Accuracy Based on Laboratory Conditions C - Carbon Monoxide (CO) EC 0 - 200 ppm 0.1 ppm ± 4% of rdg. ± 0.5 ppm Optional Gas Sensor Upgrades (Choose UPTo ANY 2) S - Carbon Dioxide (CO ) NDIR 0 - 5,000 ppm 1 ppm ± 2% of rdg. ± 10 ppm O - Oxygen (O ) EC 0 - 25%2 2C2 sories Sampling Probe (E85AACSF13)(EE900P) VOC Select Your VOC Range: Parameter Sensor Range (0 - 46,000 μg/m )3V1- PID 0 - 20,000 ppbLow Range VOC V2- PID 0 - 200 ppmHigh Range VOC (0 - 460 mg/m )3 ALL AQ VOC Kits Include: AQ VOC ORDERING CODE Part #: VOC- ___ - ___ - ___ Example: Part #: VOC - 1 - F - C2 = 2Low Range VOC, CH O, CO Operating Manual Quick Reference Guide Temperature, % Relative Humidity Continuous Active Internal Sampling Pump Long Lasting Battery AC Charger Factory Calibration Certificate Barometric Pressure PC Software USB Cable Bluetooth Connectivity Protective Carrying Case REAL-TIME Continuous Data-Logging 2 (0 - 46,000 μg/m )3 (1 μg/m )3 PID 0 - 20,000 ppb 1 ppb ±10 % of rdg. ± 20 ppb (1 mg/m ) PID 0 - 200 ppm 1 ppm ±10 % of rdg. ± 2 ppm (0 - 460 mg/m ) 3 Low Range VOC High Range VOC Pt100 ± 2% RH OR 3 Differential Pressure Bridge ±8.0 in H O 0.1 inH O ±1% of rdg.2 2 (±20 mbar) (0.25 mbar) Air Velocity 0 - 300 ft/secCalculated Pitot Tube (BB610032) for Air Velocity 1 1 2 2 2 2 2 2 2 2. 3,4 1 1 1 1 1. 3. 4. This sensor may have interference from H2 , CO, H2S and other reducing gases such as alcohols (AQ CAL-ZF) Zero Filter for Calibration (AQMET) Moisture Exchange Tube for Calibration y Conditions f Zero Filter for ation ± 2 mbar ± 0.4°C (0 - 60°C)0.1°C/F 0.1% RH 1 ft/sec 0 - 10,000 ppb 0 - 20 ppm 0.1% ± 0.1% vol rdg. 0 - 250 ppm 0.1 ppm 0.1 ppm 0.1 ppm ± 4% of rdg. ± 0.5 ppm ± 4% of rdg. ± 0.5 ppm
  • 52. CO˺ Incubator Monitor The Latest in Incubator Monitoring Real-Time Data-Logging for Air Quality Analysis for Incubators E Instruments International P: 215-750-1212 A: 402 Middletown Blvd, Suite 216 Langhorne, PA 19047 www.E-Inst.com Built with Quality in Mind AQ INCUBA Relative Humidity Temperature CO2 Measurement Ranges of: (0 - 5%, 0 - 10%, 0 - 20%) MADE IN USA Active Internal Sampling Pump Long Lasting Rechargeable Battery Barometric Pressure CO˺ User Friendly Interface REAL-TIME Data-Logging Large Internal Memory (2000) Real-Time Data-Logging for Graphs, Data Review, IAQ Reports ReaeaRea Wireless Communications with Computer Remote Printer Wire Light Weight, Durable, Hand-Held Design Lig Accessories: Real-Time PC Software Protective Magnetic Hands-Free Boot Optional Wireless Printer Optional Temperature Probe Temp. Fast Reliable Accurate Samplililing Pump ttery etric Pressure ce E Data-Logging 000) ess CoCommunicationns wiitttttttthn ommp t oot %RH
  • 53. P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 E Instruments International www.E-Inst.com Applications Bulletin:AQINCUBA.1Ed.04/2017Informationdesignsubjecttochangeatthemanufacture’sdiscretion.’ AQ Gas Real-time Datalogging Software ® AQ INCUBAAQ INCUBA % RH CO2 Temp P. Bar O2 Ambient CO2 Temperature Type K T1 Specifications Parameter Sensor Range Res. Accuracy NDIR 0 - 5% 0.1°C/F Tc K (0 - 1100°C) (-40 - 125°C) Electomagnetic Compatibility EN 61326-1, Portable Equipment Temperature -40 - 257°F Pt100 5°F (3°C) or 2% of rdg1°C/F 0 - 2000°F ± 0.4°C (0 - 60°C) ± 3% of rdg.0.1% 0 - 25% ± 0.1% vol rdg.ElectrochemicalO2 0.1% Barometric Pressure Solid State 260 - 1260 mbar 1 mbar ± 2 mbar 0 - 10% 0 - 20% 0.1% 0.1% ± 3% of rdg. ± 3% of rdg. ALL AQ INCUBA Kits Include: Ɣ Continuous Active Internal Sampling Pump Ɣ Operating Manual Ɣ Long Lasting Battery AC Charger Ɣ Factory Calibration Certificate Ɣ Differential Temperature Features CO2 Measurement Ɣ Sampling Hose Filter Ɣ Barometric Pressure Moisture Removal SystemƔ AQ INCUBA ORDERING CODE AQ INCUBA Kit CO2 Ambient Temp 100 O (0 - 25%)2 101 Optional Accessories Wireless Bluetooth™ Printer (EE900P) (E1500SP) Temperature Probe (AQMET) Moisture Exchange Tube 102 Barometric Pressure 0 - 5% 0 - 10% 0 - 20% Option Option Option Relative Humidity TFC 5 - 95% RH 0.1% RH ± 2% RH % Relative Humidity Ɣ (TRH-EXT) Temp. RH Extension Probe Temp. RH (AQ650078) Pack of 3 Moisture Filters
  • 54. Easy to Use Menu System Optional Wireless Printer Barometric Air Pressure Optional Air Sampling Probe Large Internal Memory (2000) Portable Indoor Air Quality Monitor PC Software USB Included Long Lasting Rechargeable Battery E Instruments International www.E-Inst.com P: 215-750-1212 Wireless Communications with Computer Remote Printer Light Weight, Durable, and Easy to Transport Design F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 CO CO2 Customize UP to 7 Gases Providing the latest in Monitoring Data Logging for IAQ testing in Buildings, Hospitals, Universities, Labs, Clean Rooms, Airports more Portable w/ Swivel Handle Real-Time Data-Logging Software For Graphs, Data Review, IAQ Reports AQ EXPERT REAL-TIME Continuous Data-Logging Active Internal Sampling Pump Dual Temp TcK Inputs “Built with Quality in Mind” % RH Temp Barometric Pressure H S2 VOC Formaldehyde O2 NO2 NO 2SO O3 MADE IN USA (Multiple Parameters - Up to 12)
  • 55. P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 E Instruments International www.E-Inst.com Features Applications CO2, CO, % RH, Temp, TVOC’s, O2, NO, NO2, O3, CH2O, SO2, H2S, Barometric Pressure Easy Calibration Custom to Your Application REAL-TIME Data Logging Save and graph using USB or wireless Bluetooth to a Computer or Tablet Made in USA Designed and manufactured in the USA AQ EXPERT NO CO2 O2 CO NO2 SO2 H2S NNNNNNOOOOOOOOOO % RH Built-in menu driven calibration procedure CH2O AQ Gas Real-Time Datalogging Software AQ G R l T ® Up to 7 different toxic gases to meet the needs of most air quality analyses VOCs VOCs
  • 56. Sampling Probe P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 E Instruments International www.E-Inst.com Accessories AQ EXPERT Wireless Bluetooth Printer Carrying Case Air Velocity w/ Pitot Tube Parameter Sensor Range Res. Accuracy CO O2 Electrochemical 0 - 25% 0.1% ±0.1% vo rdg.l 0 - 200 ppm 0.1 ppm ±4% of rdg. ±0.5 ppm Electrochemical 0 - 100 ppm 1 ppm ±4% of rdg. ± 0.5 ppm Electrochemical NDIR 0 - 5,000 ppm 1 ppm ±2% of rdg. ±10 ppm PID 0 - 20,000 ppb 1 ppb ±10 % of rdg. ± 20 ppb HR%2±HR%1.0HR%59-5eviticapaCmliFnihT Pt100 -40 - 257°F 0.1°C/F ±2°F (32-140°F) Electrochemical 0 - 5 ppm 1 ppb VOCs % RH Temperature Ambient Ozone (O ) CO2 H S2 Specifications CO2 NDIR 0 - 20% 0.1% ±3% of rdg. VOCs PID 0 - 200 ppm (-40 - 125°C) (± 0.4°C [0-60°C]) 3 (0 - 46,000 μg/m ) (1 μg/m ) (0 - 460 mg/m ) (1 mg/m )3 3 3 3 1 ppm Other Ranges are Available Upon Request Accuracy Based on Laboratory Conditions1. 2. 3. 1 1 CH O2 bpp05±.gdr% of5bpp1lacimehcortcelE Barometric Pressure Solid State Temperature Type K T1 T2 Tc K 0 - 2000°F 1°C/F 2% of rdg. (0 - 1100°C) Air Velocity 0 - 300 ft/sec 1 ft/secCalculated Electrochemical 0 - 20 ppm 0.1 ppmNO2 NO Electrochemical 0 - 250 ppm 0.1 ppm 2SO Electrochemical 0 - 20 ppm 0.1 ppm Differential Pressure Bridge ±40.0 inH O 0.1 inH O ±1% of rdg.2 2 (±100 mbar) (0.25 mbar) 260 - 1260 mbar 1 mbar ±2 mbar Electromagnetic compatibility EN 61326-1, Portable Equipment 0 - 10,000 ppb 2,3 1 1 1 ±10 % of rdg. ± 2 ppm This sensor may have interference from H2 , CO, H2S and other reducing gases such as alcohols Moisture Exchange Tube for Calibration Ambient Air Zero Filter Exchange Calibration Ambient Air Zero Filter ±4% of rdg. ±0.5 ppm ±4% of rdg. ±0.5 ppm ±4% of rdg. ±0.5 ppm ± ±
  • 57. P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047 E Instruments International www.E-Inst.com AQ EXPERT ORDERING CODE Part Number: EXPERT-___-___-___-___-___ (Example: EXPERT-C2-C-V1 = 2 Ambient Temp, % RH, Barometric Pressure, CO (0-5000 ppm), CO (0-200 ppm), VOC (0-20,000 ppb) AQ EXPERT Base Unit Including: - Ambient Temperature, % Relative Humidity - Barometric Pressure, Wet Bulb Dew Point - - REAL-TIME data logging - PC Software (with USB Cable) - Wireless Bluetooth External Dongle - Dual-channel TcK (Diff. Temp) - Differential Pressure - Operating Manual - Swivel Handle for Easy Transport - Rechargeable Battery AC Charger - Factory Calibration Certificate ADD UP TO 7 (SEVEN) ADDITIONAL SENSORS FROM THE LIST BELOW: PART NUMBER DESCRIPTION Expert- AQ Expert Base Unit w/ Ambient Temp, %RH, Barometric Pressure 2CO Sensor (0-5,000 ppm)-C2 -C CO Sensor (0-200 ppm) -V1 VOC Sensor (0-20,000 ppb) -V2 VOC Sensor (0-200 ppm) -N NO2 Sensor (0-20 ppm)** -Z O3 Sensor (0-5 ppm)** -H H2S Sensor (0-100 ppm) -O O2 Sensor (0-25%) -S SO2 Sensor (0-20 ppm)** -X NO Sensor (0-250 ppm) -F CH2O Sensor (0-10,000 ppb) OPTIONAL ACCESSORIES: PART NUMBER DESCRIPTION E858140 Protective Carrying Case E85AACSF13 12” (300mm) Probe, 10’ (3m) Dual Hose EE900P Bluetooth Wireless Printer BB610032 12” (300mm) Pitot Tube (Air Velocity) AACKP01 Differential Pressure Kit AQ EXPERT * * * * * Other Ranges are Available Upon Request Bulletin:AQEXPERT.2Ed.01/2017Informationdesignsubjecttochangeatthemanufacture’sdiscretion. Note: All 3 O3, NO2, SO2 Sensors Cannot Concurrently be Installed on one Instrument ** - Differential Temperature * Continuous Internal Sampling Pump * AQ CAL-ZF Ambient Air Zero Filter AQ MET Moisture Exchange Tube for Calibration
  • 58. Application Notes Indoor Air Quality E Instruments is Proud to Offer A Wide Variety of In-Depth Application Notes to its Customers Such As: The Toxic Effects of Hydrogen Sulfide (H˺S) Gas From Sewers on Health Infrastructure Application Note # AQ-14-0723 VOCs: An Indoor Air Quality Health RiskApplication Note # AQ-13-0601 Warehouses Why Energy Auditors Need to Measure CO˺Application Note # AQ-14-0313 Manufacturing Facilities Architecture Buildings For a Complete List of Our Application Notes Please Visit Our Website at www.E-Inst.com Laboratories Hospitals Medical Incubators Research Development Clean Rooms Building Hygiene Industrial Hygiene LEED Certification Universities
  • 59. Air Quality Probes Accessories 12(300mm) Standard Probe (gas draft), 1470F (800C) max, with 10'(3m) dual hose Standard Probe Temp. %RH module extension cable for testing inside incubators Temperature Humidity Module Extension Tem cable ity Hose and moisture filter for testing inside incubatorsIncubator Sampling Hose Tubing for equalizing humidity in span gas with atmosphereMoisture Exchange Tube T in (See Figure 1 Below) Disposable filter for simple zero calibration of gas sensorsAQ Zero Filter be diity Disposa calibratFilter (Figure 1)
  • 60. For more information about our products please call: (215) 750-1212 or visit our website at: www. E-Inst.com Built With Quality In Mind E Instruments International is a designer, manufacturer, provider of a complete range of innovative instrumentation solutions including portable combustion gas and emissions analyzers, automotive exhaust analyzers, gas leak detectors, and IAQ Monitors, which we export to over 65 countries worldwide. more