Different appendices to numerous material tests offered at Micom LaboratoriesMichel Comtois
Learn more about different appendices about Color Measurement, Classification of blistering test results according to ASTM D714, Classification of corrosion test results according to ASTM D610, Classification of creepage test results according to ASTM D1654 and Classification of adhesion test results according to ASTM D3359. Learn more.
Comment choisir les essais de meubles de bureau ?Michel Comtois
Si vous souhaitez vendre votre mobilier de bureau au Canada ou aux États-Unis, vos produits doivent se conformer à des normes précises. L’arbre décisionnel qui suit vous aidera à déterminer les essais les plus applicables.
Comment choisir les bons essais d’emballage ?Michel Comtois
De nombreux essais sont disponibles pour tester la performance et la durabilité de vos emballages. L’arbre décisionnel qui suit vous aidera à mieux comprendre com- ment choisir le bon essai d’emballage pour vos produits.
What is the difference between the “true” color of an item and its “perceived” color (by the human eye)? Learn more about the true color vs perceived color.
Different appendices to numerous material tests offered at Micom LaboratoriesMichel Comtois
Learn more about different appendices about Color Measurement, Classification of blistering test results according to ASTM D714, Classification of corrosion test results according to ASTM D610, Classification of creepage test results according to ASTM D1654 and Classification of adhesion test results according to ASTM D3359. Learn more.
Comment choisir les essais de meubles de bureau ?Michel Comtois
Si vous souhaitez vendre votre mobilier de bureau au Canada ou aux États-Unis, vos produits doivent se conformer à des normes précises. L’arbre décisionnel qui suit vous aidera à déterminer les essais les plus applicables.
Comment choisir les bons essais d’emballage ?Michel Comtois
De nombreux essais sont disponibles pour tester la performance et la durabilité de vos emballages. L’arbre décisionnel qui suit vous aidera à mieux comprendre com- ment choisir le bon essai d’emballage pour vos produits.
What is the difference between the “true” color of an item and its “perceived” color (by the human eye)? Learn more about the true color vs perceived color.
Ce document présente une la nouvelle norme de chaises BIFMA pour usagers de masse plus importante. Apprenez davantage. Contactez nous pour plus de renseignements.
2005 mechanical testing to ANSI/BIFMA x5.4 & quote lounge and public seating ...Michel Comtois
This document shows the 2005 mechanical testing to ANSI/BIFMA x5.4 & quote lounge and public seating tests compared to the 2012 official version. Learn more:
Cette présentations offre un aperçu des services offerts chez les Laboratoires Micom. Micom offre les essais sur les matériaux, les essais sur emballage, les essais UV, et plusieurs autres. Contactez nous pour plus d'information.
This packaging testing presentation was given at Norampac. Learn more about package testing services offered at Micom Laboratories. Contact us for more information.
ISTA 3A Présentation sur les essais sur emballageMichel Comtois
Cette présentation des Laboratoires Micom offre plus d'information sur les essais sur emballage. La présentation a été donnée à Bombardier Recreational Products & Vehicles.
ASTM testing and other material testing services available at MicomMichel Comtois
Corrosion testing is often done by using ASTM B117. Corrosion is the gradual destruction of materials, (usually metals), by chemical reaction with its environment. Corrosion degrades the useful properties of materials and structures, including strength, appearance and permeability to liquids and gases.
ASTM B117 is an accelerated corrosion testMichel Comtois
ASTM B117 is used to produce relative corrosion resistance information for specimens of metals and coated metals exposed in a standardized corrosive environment.
According to ASTM International, ASTM B117, in and of itself, is not a test specification. Rather, it outlines the standard practice for operating salt spray (fog) apparatus. B117 is a document establishing the parameters and requirements for operating a salt spray test chamber. It specifies how to create and maintain the salt fog test environment so that results can be achieved consistently from lab to lab and chamber to chamber.
ISTA 3A Packaging Test for .COM retailers offered at Micom LaboratoriesMichel Comtois
ISTA 3A tests packaged products for parcel delivery system shipment weighing 150 lbs or less. This test is used to simulate courier companies shipping environments. ISTA 3A is often required by .COM retailers.
Micom offers ISTA 3A testing as part of its Package testing services. Alternatively, the ASTM D4169 can also be considered.
ISTA 1A - Packaging test offered at Micom LaboratoriesMichel Comtois
ISTA 1A tests packaged products weighting 150 LB (68 KG) or less. It can be considered as one of the most basic test sequence of all of the ISTA test procedures. It can alsos to be considered as a screening test. If you need to qualify your package for selling to the .com retailers, ISTA 3A should be used instead. Micom offers ISTA 1A testing as part of its Package testing services.
UV Testing Decision Tree ASTM G154 vs. ASTM G155Michel Comtois
When it comes to UV exposure testing, many tests, standards and methods exist, and Micom is happy to offer numerous different UV tests that, alone and combined, help our customers better understand their products. This decision tree will help you understand when to choose ASTM G154 or ASTM G155 as a UV Test.
ASTM B117 Testing quality control by Micom LaboratoriesMichel Comtois
ASTM B117 Testing, also known as a Standard Practice for Operating Salt Spray (Fog) Apparatus, is used to analyze relative corrosion for specimens of metals and coated metals exposed to various simulated climatic conditions in a controlled environment. This testing practice was initially published in 1939 and rapidly gained worldwide acceptance across all major industry segments.
How to Validate Temperatures Within the Supply ChainMichel Comtois
Michel Comtois, President of Micom Laboratories made this presentation to the Pharmaceutical and Personal Care Logistics Association.
The theme of the presentation: Documenting through testing and monitoring that we are in control of our logistics process from a temperature standpoint.
Les essais de simulation de transport - PAC, Montreal mars 2016Michel Comtois
Le fondateur et PDG de Laboratoires Micom Inc., Michel Comtois présente “Les essais de simulation de transport ; un outil d’écoconception ” lors de la Conférence d’optimisation d’emballage: un symposium et un atelier de type conférence qui explore les concepts économiques et offre une panoplie de solutions pour optimiser l’emballage et de réduire les déchets d’emballages.
Uv testing measurements before, during and afterMichel Comtois
Upon doing UV testing gloss and color measurements are often used to monitor appearance changes. New gloss related measurements allow to better quantify what the eye can perceive to provide a better assessment.
Packaging testing to increase package sustainabilityMichel Comtois
Packaging testing standards use pass/fail criteria to establish package resistance. These standards can be used as design tools to establish desigh criteria when a package to be designed needs to be shipped through defined distribution pipelines
Ce document présente une la nouvelle norme de chaises BIFMA pour usagers de masse plus importante. Apprenez davantage. Contactez nous pour plus de renseignements.
2005 mechanical testing to ANSI/BIFMA x5.4 & quote lounge and public seating ...Michel Comtois
This document shows the 2005 mechanical testing to ANSI/BIFMA x5.4 & quote lounge and public seating tests compared to the 2012 official version. Learn more:
Cette présentations offre un aperçu des services offerts chez les Laboratoires Micom. Micom offre les essais sur les matériaux, les essais sur emballage, les essais UV, et plusieurs autres. Contactez nous pour plus d'information.
This packaging testing presentation was given at Norampac. Learn more about package testing services offered at Micom Laboratories. Contact us for more information.
ISTA 3A Présentation sur les essais sur emballageMichel Comtois
Cette présentation des Laboratoires Micom offre plus d'information sur les essais sur emballage. La présentation a été donnée à Bombardier Recreational Products & Vehicles.
ASTM testing and other material testing services available at MicomMichel Comtois
Corrosion testing is often done by using ASTM B117. Corrosion is the gradual destruction of materials, (usually metals), by chemical reaction with its environment. Corrosion degrades the useful properties of materials and structures, including strength, appearance and permeability to liquids and gases.
ASTM B117 is an accelerated corrosion testMichel Comtois
ASTM B117 is used to produce relative corrosion resistance information for specimens of metals and coated metals exposed in a standardized corrosive environment.
According to ASTM International, ASTM B117, in and of itself, is not a test specification. Rather, it outlines the standard practice for operating salt spray (fog) apparatus. B117 is a document establishing the parameters and requirements for operating a salt spray test chamber. It specifies how to create and maintain the salt fog test environment so that results can be achieved consistently from lab to lab and chamber to chamber.
ISTA 3A Packaging Test for .COM retailers offered at Micom LaboratoriesMichel Comtois
ISTA 3A tests packaged products for parcel delivery system shipment weighing 150 lbs or less. This test is used to simulate courier companies shipping environments. ISTA 3A is often required by .COM retailers.
Micom offers ISTA 3A testing as part of its Package testing services. Alternatively, the ASTM D4169 can also be considered.
ISTA 1A - Packaging test offered at Micom LaboratoriesMichel Comtois
ISTA 1A tests packaged products weighting 150 LB (68 KG) or less. It can be considered as one of the most basic test sequence of all of the ISTA test procedures. It can alsos to be considered as a screening test. If you need to qualify your package for selling to the .com retailers, ISTA 3A should be used instead. Micom offers ISTA 1A testing as part of its Package testing services.
UV Testing Decision Tree ASTM G154 vs. ASTM G155Michel Comtois
When it comes to UV exposure testing, many tests, standards and methods exist, and Micom is happy to offer numerous different UV tests that, alone and combined, help our customers better understand their products. This decision tree will help you understand when to choose ASTM G154 or ASTM G155 as a UV Test.
ASTM B117 Testing quality control by Micom LaboratoriesMichel Comtois
ASTM B117 Testing, also known as a Standard Practice for Operating Salt Spray (Fog) Apparatus, is used to analyze relative corrosion for specimens of metals and coated metals exposed to various simulated climatic conditions in a controlled environment. This testing practice was initially published in 1939 and rapidly gained worldwide acceptance across all major industry segments.
How to Validate Temperatures Within the Supply ChainMichel Comtois
Michel Comtois, President of Micom Laboratories made this presentation to the Pharmaceutical and Personal Care Logistics Association.
The theme of the presentation: Documenting through testing and monitoring that we are in control of our logistics process from a temperature standpoint.
Les essais de simulation de transport - PAC, Montreal mars 2016Michel Comtois
Le fondateur et PDG de Laboratoires Micom Inc., Michel Comtois présente “Les essais de simulation de transport ; un outil d’écoconception ” lors de la Conférence d’optimisation d’emballage: un symposium et un atelier de type conférence qui explore les concepts économiques et offre une panoplie de solutions pour optimiser l’emballage et de réduire les déchets d’emballages.
Uv testing measurements before, during and afterMichel Comtois
Upon doing UV testing gloss and color measurements are often used to monitor appearance changes. New gloss related measurements allow to better quantify what the eye can perceive to provide a better assessment.
Packaging testing to increase package sustainabilityMichel Comtois
Packaging testing standards use pass/fail criteria to establish package resistance. These standards can be used as design tools to establish desigh criteria when a package to be designed needs to be shipped through defined distribution pipelines
2. www.micomlab.com
Quel est la différence entre la couleur «
réelle » d’un article et sa couleur « perçue »
(par l’œil humain) ?
Tout comme le DOI et RIQ sont préférables aux mesures traditionnelles de lustre lorsque vous souhaitez évaluer
la « brillance » perçue d’une surface, il y a plusieurs façons de mesurer la couleur. Cela peut être une surprise pour
vous, mais la couleur n’est pas une valeur absolue. Nous expliquerons plus loin, le concept de couleur réelle et de
couleur perçue.
Le cerveau humain travaille seulement sur des perceptions sans référence absolue ou ligne de base. De plus,
chacun a une perception très unique de la couleur basée sur l’efficacité de ses récepteurs de lumière (cônes). Les
scientifiques ont essayé de normaliser les couleurs (comme ils l’ont fait pour le temps, la masse ou la distance) mais
combien de nous font référence au jaune comme étant la ligne D du sodium à 589 nm?
Maintenant vient la partie plus subtile : même si nous pouvions définir la couleur « réelle » d’un jaune pur), ce
même jaune pur quantifié avec des valeurs standards Ljaune, ajaune, bjaune, tel que défini par ASTM D2244, sera perçu
différemment selon les conditions de la surface de l’objet (texture et lustre) sur lequel il est appliqué.
Tel que les lustremètres peuvent maintenant mesurer le DOI et RIQ, les nouvelles générations de
spectrophotomètres peuvent être programmés pour tenir compte (ou pas) de la composante spéculaire pour
mesurer, respectivement, la couleur réelle ou la couleur perçue d’un objet.
1 Veuillez consulter notre présentation « Au-delà du lustre … » pour plus d’informations sur
ce sujet.
2 Les coordonnées L.a.b. font référence à la mesure de couleur faite dans un système
appelé la « sphère L.a.b. » comme indiquée ci-dessous :
Pour mesurer la couleur réelle d’un élément, toute
la lumière réfléchie doit être capturée, quel que
soit l’angle de réflexion (spéculaire, dispersée ou
diffuse) : par conséquent, ce type de mesure est
appelé : SCI (Specular Component Included) ou
Composante Spéculaire Incluse.
MESURE DE LA COULEUR RÉELLE
Pour mesurer la couleur perçue d’un élément, la
composante spéculaire (qui est généralement le
type dominant de réflexion) est exclue pour rendre
le résultat plus sensible à la lumière diffusée
causée par les conditions de la surface (brillance
et texture) : par conséquent, ce type de mesure est
appelé : SCE (Specular Component Excluded) ou
Composante Spéculaire Exclue.
MESURE DE LA COULEUR PERÇUE
3 La réflexion spéculaire est le reflet parfait (rayons entrants et sortants ont exactement le
même angle)
4 Catégories de réflexions :
3. www.micomlab.com
La couleur perçue est affectée par le rapport
de réflexions spéculaire et diffuse
Pour la même couleur réelle mesurée, la couleur perçue peut être différente, selon la position de l’observateur
(par rapport à l’angle de réflexion spéculaire de la source lumineuse et son environnement : réflexion du sol ou les
objets adjacents). Les quatre images ci-dessous proviennent du même objet : une boule de billard rouge solide.
Source de lumière (lumière blanche)
Observateur
Pure réflexion spéculaire de la source
lumineuse (point « culminant »)
4. www.micomlab.com
La couleur perçue est affectée par le lustre
Deux objets identiques avec la même couleur réelle seront perçus comme ayant une couleur vive ou terne en
fonction du lustre.
Les surfaces avec un lustre élevé (c.-à-d. : 70 unités ou plus) et une forte composante spéculaire apparaîtront
comme plus saturées en couleurs (vives).
Les surfaces semi-lustrées (typiquement 20-70 unités) paraîtront moins saturées en raison de la plus faible
composante spéculaire.
Les surfaces mates (20 unités ou moins), ayant une faible composante spéculaire, apparaissent plus ternes.
Comme une image vaut mille mots, nous allons voir un exemple graphique de ce à quoi ressemble la couleur
perçue vs la couleur réelle:
À cet angle, il n’y a aucune réflexion spéculaire atteignant notre œil, nous
voyons en réalité l’échantillon en mode « SCI », nous voyons la couleur
réelle. Le lustre et la texture de l’objet n’affectent pas notre jugement de la
couleur.
Quand nous faisons tourner l’échantillon vers la source lumineuse, la
composante spéculaire qui est réfléchie des surfaces les plus lisses et
lustrées commence à augmenter, donc notre cerveau reçoit désormais des
informations différentes des 3 surfaces. Nous passons en mode SCE.
Quand l’échantillon est mis à plat sur la table, le cerveau voit clairement
3 différentes « couleurs ».La composante spéculaire réfléchie de surface
lustrée, la fait apparaître saturée en couleurs (vive) et les deux autres
semblent plus ternes. Nous sommes maintenant en mode SCE pur, nous ne
pouvons pas dire quelle est la couleur « réelle ». Nous pouvons seulement
dire qu’elles semblent différentes. Pour déterminer laquelle est la bonne,
nous avons besoin d’une référence ou « couleur cible». À ce stade, tout
dépend de l’aspect esthétique recherché (Recherchez=vous apparence
relaxante ou éclatante ?).
IMAGE 1
IMAGE 2
IMAGE 3
5. www.micomlab.com
Valeurs mesurées en mode SCI et SCE
Les tableaux ci-dessous montrent les valeurs mesurées en mode SCI et SCE. Comme prévu, en mode SCI, Les 3
surfaces ont la même couleur (réelle) avec très peu de différences (un petit ΔE). Comme les 3 mesures ont été prises
sur le même échantillon moulé d’un même mélange; on s’attendrait en effet à la même valeur de couleur.
Ce qui est intéressant, c’est qu’en mode SCE (couleur perçue), nous pouvons voir que l’état de la surface fait une
énorme différence dans les lectures de couleur. Nous voyons que les valeurs de L (axe noir-blanc) sont beaucoup
plus élevées pour les échantillons mats, ce qui signifie qu’ils ont l’air plus blancs. C’est exactement ce que nous avons
« perçu » lorsque les échantillons été posés sur la table (image 3).
Spectrophotometer SCI mode L* (D65) a*(D65) b*(D65) L a b E
Bronze Target 30,97 2,45 3,15 ----- ----- ----- -----
Bronze Gloss = 81 30,97 2,44 3,13 0,00 -0,01 -0,02 0,02
Bronze Gloss = 7 30,48 2,56 3,25 -0,49 0,11 0,10 0,51
Bronze Gloss = 3 30,84 2,47 3,10 -0,13 0,02 -0,05 0,14
Spectrophotometer SCE mode L* (D65) a*(D65) b*(D65) L a b E
Bronze Target 19,59 4,12 7,07 ----- ----- ----- -----
Bronze Gloss = 81 19,61 4,11 7,06 0,02 -0,01 -0,01 0,02
Bronze Gloss = 7 29,07 2,72 3,54 9,48 -1,40 -3,53 10,21
Bronze Gloss = 3 30,54 2,48 3,18 10,95 -1,64 -3,89 11,74
Mesures en mode SCI (couleur réelle)
Mesures en mode SCE (couleur perçue)
Conclusion
Si vous avez besoin de vérifier la couleur d’une formulation pour vous assurer que la production est conforme (c’est-
à-dire : quantité de colorant ajouté à un polymère de base, recette de peinture...) et rencontre votre norme de qualité,
le mode SCI (couleur réelle) doit être utilisé.
Si vous voulez mesurer l’apparence d’un objet (perception de la couleur) ou l’aspect de la même couleur réelle sur
diverses surfaces, le mode SCE (couleur perçue) doit être utilisé. Le mode SCE est également un outil très puissant qui
peut mettre des chiffres sur la perception d’une couleur. Au lieu de rejeter un lot de produit parce qu’il ne semble pas
bon, vous pouvez maintenant mettre des nombres et un critère de réussite/échec sur la couleur perçue.
Être conscient de la différence entre SCE et SCI est critique lorsque vous faites du vieillissement accéléré (que ce soit
un vieillissement à la lumière ou des essais de corrosion accélérée). Cela vous permet d’avoir une approche en phase
avec les attentes de l’utilisateur. Après tout, n’est-ce pas cela qui compte ? Assurer la satisfaction de l’utilisateur.