The Serinus 40 Oxides of Nitrogen analyser delivers precise and reliable performance at excellent value. It uses proven chemiluminescence technology to measure NO, NO2 and NOx in ambient air (LDL <0.4 ppb, range 0-20 ppm).
The Serinus 44 analyser delivers precise and reliable performance at excellent value. It uses proven chemiluminescence technology and an external thermal catalytic converter to measure NO, NO2, NOx and NH3 in ambient air (LDL < 0.4 ppb, Range 0 – 20 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 40 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
The Serinus 10 Ozone (O3) analyser delivers precise and reliable performance at excellent value. It uses proven non-dispersive ultraviolet (UV) absorption technology to measure O3 in ambient air (LDL < 0.5 ppb, range 0 – 20 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 35 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
The Serinus 50 Sulfur Dioxide (SO2) analyser delivers precise and reliable performance at excellent value. It uses proven pulsed UV fluorescent radiation technology to measure SO2 in ambient air (LDL <0.3 ppb, Range 0-20 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 35 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
The Exactus BAM is a real-time beta gauge built to satisfy users, regulators and those from the health community by providing truly accurate, precise, real time measurement of fine particulate matter automatically, it is a permanent installation with the capacity to be portable when needed.
FEATURES & SPECIFICATIONS
Real-time, accurate results without correction factors, regardless of season or geographic location
True ambient sampling provides accurate measurement of semi-volatile nitrates and organic compounds
Lightweight, rugged construction is easily mounted on a tripod in minutes
All-weather construction allows for true ambient sampling
Operates on AC power.
The AF22M is an ultra-compact sulfur dioxide analyzer that uses UV fluorescence to measure SO2 at ppb levels. It features user-programmable ranges and average times, automatic ranging and response time, data storage, and a menu-driven display. The analyzer is free from interference using an enhanced scrubbing system and allows remote operation and data access via an onboard web server. It provides reliable performance for ambient and industrial SO2 monitoring from 0.01 to 10 ppm.
The Serinus 57 Total Reduced Sulfur analyser delivers precise and reliable performance at excellent value. It uses proven UV fluorescent radiation technology and an external thermal converter to measure TRS in ambient air (LDL <0.3 ppb, Range 0-10 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 35 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
The Serinus 44 analyser delivers precise and reliable performance at excellent value. It uses proven chemiluminescence technology and an external thermal catalytic converter to measure NO, NO2, NOx and NH3 in ambient air (LDL < 0.4 ppb, Range 0 – 20 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 40 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
The Serinus 10 Ozone (O3) analyser delivers precise and reliable performance at excellent value. It uses proven non-dispersive ultraviolet (UV) absorption technology to measure O3 in ambient air (LDL < 0.5 ppb, range 0 – 20 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 35 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
The Serinus 50 Sulfur Dioxide (SO2) analyser delivers precise and reliable performance at excellent value. It uses proven pulsed UV fluorescent radiation technology to measure SO2 in ambient air (LDL <0.3 ppb, Range 0-20 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 35 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
The Exactus BAM is a real-time beta gauge built to satisfy users, regulators and those from the health community by providing truly accurate, precise, real time measurement of fine particulate matter automatically, it is a permanent installation with the capacity to be portable when needed.
FEATURES & SPECIFICATIONS
Real-time, accurate results without correction factors, regardless of season or geographic location
True ambient sampling provides accurate measurement of semi-volatile nitrates and organic compounds
Lightweight, rugged construction is easily mounted on a tripod in minutes
All-weather construction allows for true ambient sampling
Operates on AC power.
The AF22M is an ultra-compact sulfur dioxide analyzer that uses UV fluorescence to measure SO2 at ppb levels. It features user-programmable ranges and average times, automatic ranging and response time, data storage, and a menu-driven display. The analyzer is free from interference using an enhanced scrubbing system and allows remote operation and data access via an onboard web server. It provides reliable performance for ambient and industrial SO2 monitoring from 0.01 to 10 ppm.
The Serinus 57 Total Reduced Sulfur analyser delivers precise and reliable performance at excellent value. It uses proven UV fluorescent radiation technology and an external thermal converter to measure TRS in ambient air (LDL <0.3 ppb, Range 0-10 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 35 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
Easy line EL3000 series ABB CEMS Datasheet-continuous gas analyzersENVIMART
Easy line EL3000 series ABB CEMS Datasheet-continuous gas analyzers - ABB - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
GCEM4100 extractive gas analyser codel datasheetENVIMART
The GCEM4100 is CODEL's hot extractive multi-channel gas analyzer for continuous emissions monitoring. It can measure CO, NO, NO2, SO2, HCl, CH4, CO2 and other gases simultaneously from high temperature flue gases. The system draws gas samples through a heated probe and transfers them to an analysis cabinet without extensive conditioning. It provides automatic calibration and verification of measurements using zero and span gases. The analyzer can integrate with CODEL's SmartCEM software for real-time data analysis and reporting.
EL300 multi channel water controller-tethys datasheetENVIMART
EL300 multi channel water controller-tethys datasheet - Tethys - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...ENVIMART
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for nitrite - Endress+Hauser - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
CCS 120 endress+hauser datasheet-sensor for total chlorineENVIMART
CCS 120 endress+hauser datasheet-sensor for total chlorine - Endress+Hauser - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
GCEM 40 series extractive gas analyser codel datasheetENVIMART
The document describes the GCEM 40 Series Extractive Gas Analyzer, a multi-channel gas analyzer from CODEL for continuous emissions monitoring. It can measure multiple gas species simultaneously, including CO, NO, NO2, NOx, SO2, CH4, HCl, N2O, CO2, H2O, and O2. It features automatic zero and span calibration, heated probe and sample line, and outputs data in real-time to meet regulatory requirements. The gas analyzer works with CODEL's SmartCEM software for graphing and reporting emissions data over time.
BOD measurement biox bod measurement datasheet endress+hauserENVIMART
BOD measurement biox bod measurement datasheet - Endress+Hauser - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
Energy tech 301 codel datasheet-dust monitorENVIMART
The EnergyTech 301 is a low-cost dust monitor that uses tribo-electric sensor technology to directly measure particulate concentration. It can monitor ducts from 250mm to 5m in size, requires minimal maintenance, and provides accurate measurements from 0.07 to 6500 mg/m3. The monitor has integrated calibration functions, alarm outputs, RS485 and 4-20mA outputs, and is suitable for a wide range of applications.
Our COMETS is the perfect compact ambient air monitoring station. Fully air-conditioned, automated and according to EU guidelines.
This monitoring station can be placed anywhere in critical places such as busy intersections, street canyons, temporary background stations and much more.
The compact station comes with a complete solution such as NO, NO2, NOx, CO, PM10 - PM2.5, Black Carbon and BTEX analyzer, logger and platform.
It is constructed in such a way that minimal maintenance is required. The station can work autonomously and data can be viewed, analyzed and validated remotely using our state-of-the-art logger and "air quality data platform".
The Serinus 56 Total Sulfur analyser delivers precise and reliable performance at excellent value. It uses proven UV fluorescent radiation technology and an external thermal converter to measure TS in ambient air (LDL <0.3ppb, Range 0-10 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 35 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
The Serinus range of analyzers have been designed using over 40 years of experience in air quality monitoring. They integrate seamlessly into continuous monitoring networks and offer benefits such as a two year warranty, minimal maintenance needs through remote access and diagnostics, versatile interfacing options, intuitive menu systems, removable flash memory storing 10 years of data, and low power consumption. The Serinus 31 specifically measures carbon dioxide concentration using proven NDIR filter correlation technology, and has a range of 0-2000 ppm with approvals from various standards organizations. It provides remote communication and data logging capabilities.
Easy line EL3000 series ABB CEMS Datasheet-continuous gas analyzersENVIMART
Easy line EL3000 series ABB CEMS Datasheet-continuous gas analyzers - ABB - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
GCEM4100 extractive gas analyser codel datasheetENVIMART
The GCEM4100 is CODEL's hot extractive multi-channel gas analyzer for continuous emissions monitoring. It can measure CO, NO, NO2, SO2, HCl, CH4, CO2 and other gases simultaneously from high temperature flue gases. The system draws gas samples through a heated probe and transfers them to an analysis cabinet without extensive conditioning. It provides automatic calibration and verification of measurements using zero and span gases. The analyzer can integrate with CODEL's SmartCEM software for real-time data analysis and reporting.
EL300 multi channel water controller-tethys datasheetENVIMART
EL300 multi channel water controller-tethys datasheet - Tethys - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...ENVIMART
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for nitrite - Endress+Hauser - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
CCS 120 endress+hauser datasheet-sensor for total chlorineENVIMART
CCS 120 endress+hauser datasheet-sensor for total chlorine - Endress+Hauser - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
GCEM 40 series extractive gas analyser codel datasheetENVIMART
The document describes the GCEM 40 Series Extractive Gas Analyzer, a multi-channel gas analyzer from CODEL for continuous emissions monitoring. It can measure multiple gas species simultaneously, including CO, NO, NO2, NOx, SO2, CH4, HCl, N2O, CO2, H2O, and O2. It features automatic zero and span calibration, heated probe and sample line, and outputs data in real-time to meet regulatory requirements. The gas analyzer works with CODEL's SmartCEM software for graphing and reporting emissions data over time.
BOD measurement biox bod measurement datasheet endress+hauserENVIMART
BOD measurement biox bod measurement datasheet - Endress+Hauser - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
Energy tech 301 codel datasheet-dust monitorENVIMART
The EnergyTech 301 is a low-cost dust monitor that uses tribo-electric sensor technology to directly measure particulate concentration. It can monitor ducts from 250mm to 5m in size, requires minimal maintenance, and provides accurate measurements from 0.07 to 6500 mg/m3. The monitor has integrated calibration functions, alarm outputs, RS485 and 4-20mA outputs, and is suitable for a wide range of applications.
Our COMETS is the perfect compact ambient air monitoring station. Fully air-conditioned, automated and according to EU guidelines.
This monitoring station can be placed anywhere in critical places such as busy intersections, street canyons, temporary background stations and much more.
The compact station comes with a complete solution such as NO, NO2, NOx, CO, PM10 - PM2.5, Black Carbon and BTEX analyzer, logger and platform.
It is constructed in such a way that minimal maintenance is required. The station can work autonomously and data can be viewed, analyzed and validated remotely using our state-of-the-art logger and "air quality data platform".
The Serinus 56 Total Sulfur analyser delivers precise and reliable performance at excellent value. It uses proven UV fluorescent radiation technology and an external thermal converter to measure TS in ambient air (LDL <0.3ppb, Range 0-10 ppm).
The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 35 years. The result: instruments that integrate seamlessly into continuous monitoring networks.
The Serinus range of analyzers have been designed using over 40 years of experience in air quality monitoring. They integrate seamlessly into continuous monitoring networks and offer benefits such as a two year warranty, minimal maintenance needs through remote access and diagnostics, versatile interfacing options, intuitive menu systems, removable flash memory storing 10 years of data, and low power consumption. The Serinus 31 specifically measures carbon dioxide concentration using proven NDIR filter correlation technology, and has a range of 0-2000 ppm with approvals from various standards organizations. It provides remote communication and data logging capabilities.
This document provides an overview of various controllers and control solutions from WEST Control Solutions. It describes general purpose controllers, basic controllers, valve position controllers, plastics controllers, limit controllers, process indicators, profiler controllers, and the MLC 9000+ multi-loop control system. Details are given on features such as input/output options, display sizes, profiling capabilities, data logging, and communication protocols for each product line.
The PCME QAL 181 is a particulate continuous emissions monitor that provides accurate measurement of low dust concentrations. It is suitable for measuring emissions from bag filters and electrostatic precipitators. The monitor has high accuracy, operates reliably at elevated temperatures, and has online calibration capabilities to minimize drift. It can measure particulate levels from 0-300 mg/m3 and integrate with data acquisition software for regulatory reporting.
The MiniRAE 3000 is a portable handheld monitor that detects volatile organic compounds (VOCs) using photoionization detector (PID) technology. It has a wide detection range of 0-15,000 ppm VOCs, a fast response time of less than 3 seconds, and can transmit real-time data wirelessly up to 500 feet. The MiniRAE 3000 is designed to be rugged, easy to use, and low maintenance for industrial hygiene and hazardous material applications.
Co12 m carbon monoxide gfc analyser datasheeta1-cbiss
The CO12M is an IR gas filter correlation (IR-GFC) based carbon monoxide analyser that can measure CO concentrations between 40 ppb to 200 ppm with excellent stability and accuracy. It uses sealed gas cells located in a thermoregulated module and has an easy-to-use interface. Its multitasking software allows for advanced calculations and user-friendly access to instrument parameters, status, maintenance data, and real-time synoptics. It is compact, portable, and plug-and-play for continuous indoor and outdoor air quality monitoring.
The Siemens Ultrasonic Level Transmitter LUT400 arrangement controllers are conservative single point long-go ultrasonic controllers for constant level or volume estimation of fluids slurries and solids and high precision observing of open channel stream Ultrasonic Level Transmitter.The SITRANS LUT400 comes in three distinct models relying upon the application, level of execution and usefulness required.see more:- www.siemenstransmitter.com
The document describes several gas monitoring devices:
- The 4 Channel Gas Monitor is a wall-mounted unit that monitors up to 4 toxic gases, combustible gases, or oxygen levels with displays and alarms.
- The Multichannel Gas Monitor is a rack-mounted system compatible with up to 16 sensors for monitoring multiple gas channels.
- The IR80 CO2 Gas Monitor is a standalone or networked monitor for carbon dioxide levels with alarms and calibration assistance.
The DS2460Q is a multi-functional cable network testing instrument that supports both digital QAM and analog signals. It provides comprehensive spectrum analysis from 5-1220 MHz, digital TV tests including MER, BER, and constellation diagrams, and analog TV measurements for level, hum, and C/N ratio. Additional features include data logging, auto-generated channel plans, optical power measurement, and a visual fault locator. The DS2460Q is designed for installation, maintenance, and troubleshooting of cable networks.
Greystone's vision is to design and manufacture high quality sensors for measuring temperature, humidity, pressure, and other data. They realize this vision through strict adherence to quality standards, exemplary customer service, pride in work, and research/development. Greystone produces sensors and transmitters in their 2600m2 facility in Canada and has over 100 employees in 8 locations worldwide.
bioMérieux provides a full range of services and equipment for environmental monitoring and quality control. This includes Labguard monitoring systems, sensors, data loggers, and comprehensive services for evaluation, training, calibration, and support. The document describes the Labguard hardware and software platforms, types of sensors, data transmission options, and qualification and metrology services provided by bioMérieux to ensure reliable monitoring and improve quality assurance.
The Environics Series 2020 is a gas dilution system that consists of up to six mass flow controllers, a pre-mix zone, and final mixing zone to precisely dilute gases from high concentration cylinders to parts per million concentrations. It has an accuracy of 1% of full scale flow and concentration and repeatability of 0.05%. Commands are entered via the front panel or optional communications, and calibration sequences are stored internally. It is available as a benchtop or 19" rack mount unit.
Real-time spectrum analyzer RSA5000 Series
The RSA5065 real-time spectrum analyzer with real-time analysis and sweep analysis, optional vector signal analysis application software (VSA) and EMI measurement application software (EMI), with excellent performance and specifications. Its frequency range is 9kHz to 3.2GHz, and it is available with the tracking source "-TG" model, which can be widely used in enterprise R&D, factory production, education and teaching
This document provides information about Process Sensors, a company that specializes in near infrared technology for precision measurement of wood composite products. It discusses the company's history and worldwide offices and service centers. It also describes the MCT300-WP gauge for measuring moisture in wood products using near infrared technology. Key features of the gauge like its principle of operation, specifications, applications in particleboard and OSB manufacturing, and calibration procedure are summarized.
The document discusses IRD's condition monitoring technology for machines. It describes their 6600 series vibration and process monitors that meet API standards and provide vibration analysis, temperature monitoring, and data collection capabilities. The 3603 data interface unit allows connecting up to 200 monitors via RS485 and collecting data from them to transfer to host computers using Ethernet or RS232 connections. The Oliver2 software is used for long-term trending, alarm management, and vibration analysis from the collected data. IRD's systems have been selected for use by major oil and gas companies on various projects due to meeting industry standards.
The CAL range of temperature controllers are designed to be easy to use, low cost and reliable in the most demanding applications, including plastics, packaging, drying and laboratory equipment.
The document describes the specifications for a UV-Visible Spectrophotometer, including its optical system, wavelength range and readability, photometric readout range and accuracy, noise level, data interval, drift, and cell holder. It also lists the required accessories, including cuvettes, manuals, a computer, printer, and consumables for two years of operation. Additional features noted are the storage of spectra and methods, multiple analysis modes, and software for water and environmental analysis.
We fotograferen, scannen woningen, gebouwen, constructies voor vastgoedmakelaars, architecten, projectontwikkelaars, aannemers,...
Daarnaast maken we 360° scans, virtual tours, grondplannen, luchtfoto's met
drones, mapping en nog veel meer.
Diensten voor vastgoed
Standaard fotografie
3d scans
Virtual tours
2d vloerplannen
Drone foto -en videografie
Virtual staging
Nabewerken foto's
Vastgoed teaser videos
Diensten voor
constructies
Foto en video
3d scans
E57 files
Vloerplannen
Puntenwolken
Mesh bestanden
Trueplan
Luchtfoto's
en meer
XRF Based &Multi-Metals & Continuous Water Analyzer Xact920European Tech Serv
Process monitoring – feedback for water treatment may improve the efficiency of the treatment process – use fewer chemicals to achieve require effluent emission limits
Measurement of Se, As for compliance with Steam Electric Generating Effluent Guidelines
Monitoring of treatment of wastewater by biological based treatment systems
Measurement of Corrosion Products (e.g. Fe, Ni, Cr and Mn) to improve operating efficiency
Measurement of Elements in Nuclear Power Plant Applications (e.g. Pb, Cu, Fe)
Reduce laboratory analysis costs
On-line, in-situ, and at-line monitoring of batch and continuous processes
Displays up to 15 properties at once and measures up to 30 properties per stream
Optical multiplexing capabilities provide analysis of up to 16 process streams using fiber optic or extractive stream switching
Utilizes process-proven ANALECT® Diamond 20™ Transept™ optical head
SpectraRTS™ software engineered exclusively for on-line monitoring, allowing use by engineers, maintenance personnel, and chemists
All ANALECT® lab and on-line systems share core optical technology, allowing instrument-to-instrument calibration transfers
The FROG-5000™ is a portable gas chromatograph (GC) that identifies multiple target volatile organic compounds (VOC) in water, soil, and air. The FROG-5000™ detects chemicals as volatile as vinyl chloride to semi-volatile organics such as naphthalene with lab quality results.
Featuring a MEMS (micro electro-mechanical systems), the FROG-5000™ has an integrated heater for temperature ramp chromatography – ramping the temperature reduces the analysis time and aids in the separation of late eluting compounds. These components combined with an internal PID identify VOCs in ambient air at concentrations as low as 1 part per billion.
Continuous analysis:
Continuous analysis of aerosols on filters for optical and thermal analysis
OC/EC determination:
Real time/online TC/BC/EC/OC and Brc analysis in combination with our Aethalometer AE33
Ease of Use:
No fragile glassware, no catalyst, no gas supplies needed
Rugged, Reliable, automatic:
35 years of published performance, rugged, all-steel construction, unattended operation – 1 month minimum
At the core of our technology are our next‑generation air quality monitors - the Clarity Node and Node-S. These nimble monitors are configured on our web-based deployment tool and installed in a matter of minutes. Hundreds to thousands of devices work together to form a scalable network of high density air quality measurement points.
At the core of our technology are our next‑generation air quality monitors - the Clarity Node and Node-S. These nimble monitors are configured on our web-based deployment tool and installed in a matter of minutes. Hundreds to thousands of devices work together to form a scalable network of high density air quality measurement points.
At the core of our technology are our next‑generation air quality monitors - the Clarity Node and Node-S. These nimble monitors are configured on our web-based deployment tool and installed in a matter of minutes. Hundreds to thousands of devices work together to form a scalable network of high density air quality measurement points.
At the core of our technology are our next‑generation air quality monitors - the Clarity Node and Node-S. These nimble monitors are configured on our web-based deployment tool and installed in a matter of minutes. Hundreds to thousands of devices work together to form a scalable network of high density air quality measurement points.
The Mi3 is a turnkey solution for automotive emission testing that features the world's fastest particle sensor. It provides accurate real-time data, reliable measurements in all environments, and ensures measurements meet emission regulations standards. The Mi3 requires little maintenance due to its low-maintenance particle sensor and self-diagnostics. It can integrate seamlessly with existing emission test infrastructure through various connection options.
THE GAS CHROMATOGRAPHIC REVOLUTION
FOR ENVIRONMENTAL MONITORING
PyxisGC BTEX is the first and unique gaschromatograph "carrier gas free" for remote BTEX monitoring
in ambient air. PyxisGC BTEX is manufactured by Pollution Analytical Equipment in compliance with
EN14662-3:2015.
"BTEX ambient air analysis: sources, regulations, technologies for controls"European Tech Serv
"BTEX ambient air analysis: sources, regulations, technologies for
controls"
In collaboration with The Council for Research and Experimentation in Agriculture at the Puglia
Regional Environmental Protection Agency (ARPA)
The M1000 operates according to the diffusion principle. The monitor is mounted on a flange which is located at the top of the silo or bin. The gas in the atmosphere of the silo diffuses into the oxygen sensor. Since there is no positive movement of chemical powder to the sensor the sampling gas will not block filters and tubing. The right design and choice of components ensures a long term maintenance free operation.
H2scan’s HY-ALERTA™ 600 Fixed Area Hydrogen Monitor will provide hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit
H2scan’s HY-ALERTA™ 600 Fixed Area Hydrogen Monitor will provide hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit
H2scan’s HY-ALERTA™ 1600 Intrinsically Safe Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit.
H2scan’s HY-ALERTA™ 1600 Intrinsically Safe Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit.
H2scan’s HY-ALERTA™ 2600 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s lower flammability limit.
Technology background HY-ALERTA SAFETY SYSTEMS – HY-ALERTA 2600European Tech Serv
H2scan’s HY-ALERTA™ 2600 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s lower flammability limit.
Null Bangalore | Pentesters Approach to AWS IAMDivyanshu
#Abstract:
- Learn more about the real-world methods for auditing AWS IAM (Identity and Access Management) as a pentester. So let us proceed with a brief discussion of IAM as well as some typical misconfigurations and their potential exploits in order to reinforce the understanding of IAM security best practices.
- Gain actionable insights into AWS IAM policies and roles, using hands on approach.
#Prerequisites:
- Basic understanding of AWS services and architecture
- Familiarity with cloud security concepts
- Experience using the AWS Management Console or AWS CLI.
- For hands on lab create account on [killercoda.com](https://killercoda.com/cloudsecurity-scenario/)
# Scenario Covered:
- Basics of IAM in AWS
- Implementing IAM Policies with Least Privilege to Manage S3 Bucket
- Objective: Create an S3 bucket with least privilege IAM policy and validate access.
- Steps:
- Create S3 bucket.
- Attach least privilege policy to IAM user.
- Validate access.
- Exploiting IAM PassRole Misconfiguration
-Allows a user to pass a specific IAM role to an AWS service (ec2), typically used for service access delegation. Then exploit PassRole Misconfiguration granting unauthorized access to sensitive resources.
- Objective: Demonstrate how a PassRole misconfiguration can grant unauthorized access.
- Steps:
- Allow user to pass IAM role to EC2.
- Exploit misconfiguration for unauthorized access.
- Access sensitive resources.
- Exploiting IAM AssumeRole Misconfiguration with Overly Permissive Role
- An overly permissive IAM role configuration can lead to privilege escalation by creating a role with administrative privileges and allow a user to assume this role.
- Objective: Show how overly permissive IAM roles can lead to privilege escalation.
- Steps:
- Create role with administrative privileges.
- Allow user to assume the role.
- Perform administrative actions.
- Differentiation between PassRole vs AssumeRole
Try at [killercoda.com](https://killercoda.com/cloudsecurity-scenario/)
Software Engineering and Project Management - Introduction, Modeling Concepts...Prakhyath Rai
Introduction, Modeling Concepts and Class Modeling: What is Object orientation? What is OO development? OO Themes; Evidence for usefulness of OO development; OO modeling history. Modeling
as Design technique: Modeling, abstraction, The Three models. Class Modeling: Object and Class Concept, Link and associations concepts, Generalization and Inheritance, A sample class model, Navigation of class models, and UML diagrams
Building the Analysis Models: Requirement Analysis, Analysis Model Approaches, Data modeling Concepts, Object Oriented Analysis, Scenario-Based Modeling, Flow-Oriented Modeling, class Based Modeling, Creating a Behavioral Model.
Advanced control scheme of doubly fed induction generator for wind turbine us...IJECEIAES
This paper describes a speed control device for generating electrical energy on an electricity network based on the doubly fed induction generator (DFIG) used for wind power conversion systems. At first, a double-fed induction generator model was constructed. A control law is formulated to govern the flow of energy between the stator of a DFIG and the energy network using three types of controllers: proportional integral (PI), sliding mode controller (SMC) and second order sliding mode controller (SOSMC). Their different results in terms of power reference tracking, reaction to unexpected speed fluctuations, sensitivity to perturbations, and resilience against machine parameter alterations are compared. MATLAB/Simulink was used to conduct the simulations for the preceding study. Multiple simulations have shown very satisfying results, and the investigations demonstrate the efficacy and power-enhancing capabilities of the suggested control system.
CHINA’S GEO-ECONOMIC OUTREACH IN CENTRAL ASIAN COUNTRIES AND FUTURE PROSPECTjpsjournal1
The rivalry between prominent international actors for dominance over Central Asia's hydrocarbon
reserves and the ancient silk trade route, along with China's diplomatic endeavours in the area, has been
referred to as the "New Great Game." This research centres on the power struggle, considering
geopolitical, geostrategic, and geoeconomic variables. Topics including trade, political hegemony, oil
politics, and conventional and nontraditional security are all explored and explained by the researcher.
Using Mackinder's Heartland, Spykman Rimland, and Hegemonic Stability theories, examines China's role
in Central Asia. This study adheres to the empirical epistemological method and has taken care of
objectivity. This study analyze primary and secondary research documents critically to elaborate role of
china’s geo economic outreach in central Asian countries and its future prospect. China is thriving in trade,
pipeline politics, and winning states, according to this study, thanks to important instruments like the
Shanghai Cooperation Organisation and the Belt and Road Economic Initiative. According to this study,
China is seeing significant success in commerce, pipeline politics, and gaining influence on other
governments. This success may be attributed to the effective utilisation of key tools such as the Shanghai
Cooperation Organisation and the Belt and Road Economic Initiative.
Introduction- e - waste – definition - sources of e-waste– hazardous substances in e-waste - effects of e-waste on environment and human health- need for e-waste management– e-waste handling rules - waste minimization techniques for managing e-waste – recycling of e-waste - disposal treatment methods of e- waste – mechanism of extraction of precious metal from leaching solution-global Scenario of E-waste – E-waste in India- case studies.
Embedded machine learning-based road conditions and driving behavior monitoringIJECEIAES
Car accident rates have increased in recent years, resulting in losses in human lives, properties, and other financial costs. An embedded machine learning-based system is developed to address this critical issue. The system can monitor road conditions, detect driving patterns, and identify aggressive driving behaviors. The system is based on neural networks trained on a comprehensive dataset of driving events, driving styles, and road conditions. The system effectively detects potential risks and helps mitigate the frequency and impact of accidents. The primary goal is to ensure the safety of drivers and vehicles. Collecting data involved gathering information on three key road events: normal street and normal drive, speed bumps, circular yellow speed bumps, and three aggressive driving actions: sudden start, sudden stop, and sudden entry. The gathered data is processed and analyzed using a machine learning system designed for limited power and memory devices. The developed system resulted in 91.9% accuracy, 93.6% precision, and 92% recall. The achieved inference time on an Arduino Nano 33 BLE Sense with a 32-bit CPU running at 64 MHz is 34 ms and requires 2.6 kB peak RAM and 139.9 kB program flash memory, making it suitable for resource-constrained embedded systems.
Redefining brain tumor segmentation: a cutting-edge convolutional neural netw...IJECEIAES
Medical image analysis has witnessed significant advancements with deep learning techniques. In the domain of brain tumor segmentation, the ability to
precisely delineate tumor boundaries from magnetic resonance imaging (MRI)
scans holds profound implications for diagnosis. This study presents an ensemble convolutional neural network (CNN) with transfer learning, integrating
the state-of-the-art Deeplabv3+ architecture with the ResNet18 backbone. The
model is rigorously trained and evaluated, exhibiting remarkable performance
metrics, including an impressive global accuracy of 99.286%, a high-class accuracy of 82.191%, a mean intersection over union (IoU) of 79.900%, a weighted
IoU of 98.620%, and a Boundary F1 (BF) score of 83.303%. Notably, a detailed comparative analysis with existing methods showcases the superiority of
our proposed model. These findings underscore the model’s competence in precise brain tumor localization, underscoring its potential to revolutionize medical
image analysis and enhance healthcare outcomes. This research paves the way
for future exploration and optimization of advanced CNN models in medical
imaging, emphasizing addressing false positives and resource efficiency.
artificial intelligence and data science contents.pptxGauravCar
What is artificial intelligence? Artificial intelligence is the ability of a computer or computer-controlled robot to perform tasks that are commonly associated with the intellectual processes characteristic of humans, such as the ability to reason.
› ...
Artificial intelligence (AI) | Definitio
Electric vehicle and photovoltaic advanced roles in enhancing the financial p...IJECEIAES
Climate change's impact on the planet forced the United Nations and governments to promote green energies and electric transportation. The deployments of photovoltaic (PV) and electric vehicle (EV) systems gained stronger momentum due to their numerous advantages over fossil fuel types. The advantages go beyond sustainability to reach financial support and stability. The work in this paper introduces the hybrid system between PV and EV to support industrial and commercial plants. This paper covers the theoretical framework of the proposed hybrid system including the required equation to complete the cost analysis when PV and EV are present. In addition, the proposed design diagram which sets the priorities and requirements of the system is presented. The proposed approach allows setup to advance their power stability, especially during power outages. The presented information supports researchers and plant owners to complete the necessary analysis while promoting the deployment of clean energy. The result of a case study that represents a dairy milk farmer supports the theoretical works and highlights its advanced benefits to existing plants. The short return on investment of the proposed approach supports the paper's novelty approach for the sustainable electrical system. In addition, the proposed system allows for an isolated power setup without the need for a transmission line which enhances the safety of the electrical network
Electric vehicle and photovoltaic advanced roles in enhancing the financial p...
Nitrogen serinus-40-n ox-gas-analyser
1. BENEFITS
The Serinus®
range of analysers have been designed using our
experience and knowledge gained from operating large air quality
monitoring networks for more than 40 years. The result, instruments
that integrate seamlessly into continuous monitoring networks.
• Reliable performance complemented with a two year warranty
• Minimise time spent on site performing maintenance through
superior remote instrument control, diagnostic viewing and
calibration
• Comprehensive data logging and remote viewing of over 200
operational parameters
• Versatile interfacing through RS232, USB, Bluetooth, analog and
digital I/O and optional TCP/IP
• Easy setup through an intuitive menu system, advanced GUI and a
large alphanumeric keypad with tactile keys
• Instant status indication via illuminated instrument status light
buttons on the front panel
• Removable flash memory stores ~10 years of data, including up to
12 individual parameters and event logs. Operational parameters
can also be transferred to memory for easy retrieval
• Latest firmware updates can easily be installed using the USB
flash memory drive
• Programming, viewing, downloading and emailing of data is
made even simpler using Bluetooth connectivity combined with
the “ECOTECH Serinus Remote” Android App
• Built-in digital display measuring values and having function of
measuring values transferred to graphical trend display
• Enhanced operator safety through the use of 12 VDC internal
voltages
• Reduced cost of spare parts, accessories and consumable items
through extensive use of standard components across the Serinus®
range
• Rack slide design makes accessing internal components and
removing the analyser from a rack cabinet easy
• AQMS power usage can be reduced due to the instrument’s low
power demand and its ability to operate over a wide temperature
range.
Serinus®
40
OXIDES OF NITROGEN ANALYSER
The Serinus®
40 Oxides of Nitrogen (NOx
)
analyser delivers precise and reliable
performance at excellent value. It uses
proven chemiluminescence technology to
measure NO, NO2
and NOx
in ambient air
(LDL < 0.4 ppb, range 0 to 20 ppm).
APPROVALS
• US EPA approval (RFNA–0809–186)
• EN approval TÜV (936/21221977/A)
• EN approval MCERTS (MC100167/06)
• Australian Standard (AS 3580.5.1-2011)
• Russian approval (56263-14)
• French approval LSCQA