This document provides documentation for using the SMOP template designer software. It describes the workflow for dentists using SMOP, including creating a case, ordering services, planning implants, exporting data, and designing templates. It outlines how to design both tooth-supported and soft tissue-supported templates, adding features like wires, arches, and sleeve supports. Finally, it discusses the different product configurations for SMOP based on user needs like standard, basic, and chair side users.
The Most Attractive Hyderabad Call Girls Kothapet 𖠋 9332606886 𖠋 Will You Mis...
SMoP Guide Design Instructions
1. document version 181119 for smop version 2.14.2
PRODUCT DOCUMENTATION
FOR SMOP TEMPLATE DESIGNER
smop is a product and brand of Swissmeda AG, www.mysmop.com
2. document version 181120 for smop version 2.14.2
1. Create
Case
3. Prepare
Case
4. Plan
Implants
2. Order
All
Inclusive
Services
6. Order
Template
5. Export
Data
1. DENTISTS WORKFLOW WITH SMOP
Service
Partner
Service
Partner
2
7. Design
Template
3. document version 181120 for smop version 2.14.2
a. Design a tooth supported template
b. Design a soft tissue supported template
c. Plan extra screws
d. Plan extra pins
DESIGN TEMPLATE
1. Create
Case
3. Prepare
Case
4. Plan
Implants
7. Design
Template
2. Order
All
Inclusive
Services
6. Order
Template
5. Export
Data
3
4. document version 181120 for smop version 2.14.2
a. INSERTION DIRECTION (Tooth Supported Template)
Define the working direction
(pass insertion) to calculate
and display undercut areas in
yellow and red color
4
5. document version 181120 for smop version 2.14.2
a. Clamps (Tooth Supported Template)
Clamps are generated to click
and fix the template onto the
teeth of the patient
5
6. document version 181120 for smop version 2.14.2
a. LINGUAL WIRE (Tooth Supported Template)
The lingual/palatal wire is
created to stabilize and stiffen
the entire template
6
7. document version 181120 for smop version 2.14.2
a. BUCCAL WIRE (Tooth Supported Template)
The buccal wire is used to
stiffen the template (like to
the oral wire).
Contact points of the wire
should be set on every
second or third tooth
7
8. document version 181120 for smop version 2.14.2
a. ARCHES (Tooth Supported Template)
Arches are used to connect the
lingual/palatal wires to ensure
better stiffness
8
9. document version 181120 for smop version 2.14.2
a. SLEEVE SUPPORT (Tooth Supported Template)
The shape and size of sleeve
support rings can be adjusted:
The implant, the corresponding
surgical kit and the neighboring
teeth should be considered
9
10. document version 181120 for smop version 2.14.2
a. IMPRINT NAME (Tooth Supported Template)
The name of the template,
which can be edited during the
template design, will be
imprinted automatically to the
visible side on the longest
available arch of the template
10
11. document version 181120 for smop version 2.14.2
a. FINAL CALCULATION (Tooth Supported Template)
The final template calculation
combines all the designed
features into one closed surface
(STL-data), ready for printing
11
12. document version 181120 for smop version 2.14.2
b. INSERTION DIRECTION (Soft Tissue Supported)
Define the working direction
(pass insertion) to calculate
and display undercut areas in
yellow and red color
12
13. document version 181120 for smop version 2.14.2
b. MUCOSA SUPPORT (Soft Tissue Supported)
Mucosa supports can be used
to provide additional support,
if there are no
teeth available to fix the
template in the patient mouse
13
14. document version 181120 for smop version 2.14.2
b. MUCOSA SUPPORT (Soft Tissue Supported)
Extra Mucosa supports can be
added to provide additional
support
14
15. document version 181120 for smop version 2.14.2
b. LINGUAL WIRE (Soft Tissue Supported)
The lingual/palatal wire is
created to stabilize and stiffen
the entire template
15
16. document version 181120 for smop version 2.14.2
b. BUCCAL WIRE (Soft Tissue Supported)
The buccal wire is used to
stiffen the template (like to
the oral wire).
Contact points of the wire
should be set on every
second or third tooth
16
17. document version 181120 for smop version 2.14.2
b. ARCHES (Soft Tissue Supported)
Arches are used to connect the
lingual/palatal wires or the
mucosal support to ensure
better stiffness
17
18. document version 181120 for smop version 2.14.2
b. ARCHES (Soft Tissue Supported)
Arches are used to connect the
lingual/palatal wires or the
mucosal support to ensure
better stiffness
18
19. document version 181120 for smop version 2.14.2
b. SLEEVE SUPPORT (Soft Tissue Supported)
The shape and size of sleeve
support rings can be adjusted:
The implant, the corresponding
surgical kit and the neighboring
teeth should be considered
19
20. document version 181120 for smop version 2.14.2
b. IMPRINT NAME (Soft Tissue Supported)
The name of the template,
which can be edited during the
template design, will be
imprinted automatically to the
visible side on the longest
available arch of the template
20
21. document version 181120 for smop version 2.14.2
b. FINAL RESULT (Soft Tissue Supported)
The final template calculation
combines all the designed
features into one closed surface
(STL-data), ready for printing
21
22. document version 181120 for smop version 2.14.2
c. PLAN EXTRA SCREW (Soft Tissue Supported)
SMOP’s geometry library
contains geometries for bone
retention screws under different
brands
22
23. document version 181120 for smop version 2.14.2
c. PLAN EXTRA SCREW (Soft Tissue Supported)
The parameters can easily be
changed using the edit fields of
the middle toolbar, the width and
length of the holding/guiding
plastic cylinders. Outer diameter
should be 0.3mm wider than the
screw diameter
23
24. document version 181120 for smop version 2.14.2
c. PLAN EXTRA SCREW (Soft Tissue Supported)
The final template calculation
combines all the designed
features into one closed surface
(STL-data), ready for printing
24
25. document version 181120 for smop version 2.14.2
c. PLAN EXTRA PIN (Soft Tissue Supported)
In addition to the bone retention
screws, the SMOP’s library
contains geometries for bone
retention pins
25
26. document version 181120 for smop version 2.14.2
c. PLAN EXTRA PIN (Soft Tissue Supported)
26
The final template calculation
combines all the designed
features into one closed surface
(STL-data), ready for printing
27. document version 181120 for smop version 2.14.2
EXAMPLE SMALL TOOTH GAP
Courtesy of Dental Clinic, Lucerne
Copyright 2018, Dr. med. Beat Kurt
27
28. document version 181120 for smop version 2.14.2
2. BENEFITS OF SMOP - KEY FEATURE SMOP TEMPLATE
Accurate fitting in the patient mouse by using contact points on pre-defined locations (on tooth or gingiva):
Inaccurate fitting by design procedures provided by other software:
28
29. document version 181120 for smop version 2.14.2
2. BENEFITS OF THE SMOP TEMPLATE
• Full visibility on the surgical site
• Better control of the fit
• Allows cooling agent so water going into the osteotomy site reduces the frequency of pumping technique
• Easy to raise a flap
• Easier accessibility for surgical instrument insertion
• Reducing drastically the possibility of errors and distortions due to support the template only on selected stable points on
the teeth and not covering the full surface on the teeth
• This kind of balcony design will keep the flap away from the drill, but no excessive opening/exposure of the flap due to our
guide will not be necessary in contact with that gums
• Extra stabilization due to the use of palatal area. This feature “mucosa support” allows a clinician to proceed with surgery
without a need for further extra stabilization accessories such as pins or screws
• Depending on the implant system and its surgical kit no metal sleeve is needed to guide the drill (e.g. Straumann, Astra,
SIC…). The spoon of the kit can directly be plugged into the plastic-whole of the template. This increases the accuracy of
the drilling and reduces costs by saving the sleeves
Patented best template worldwide. Why the light and open “Spaghetti” design?
29
30. document version 181120 for smop version 2.14.2
The smop Template is optimized to be manufactured by 3D printing technology
Swissmeda has had good experiences using the Polyjet printers from Stratasys with the certified material MED610
2. SMOP TEMPLATE OPTIMIZED FOR 3D PRINTING
SMOP Template (output of
planning system, STL data)
SMOP Template (printed)
3D printing process
30
31. document version 181120 for smop version 2.14.2
There are a lot more 3D printers on the market supporting medical resin (e.g. Nextdent SG):
Please note, Swissmeda has no experience with the listed examples and can’t give any recommendation.
2. SMOP TEMPLATE OPTIMIZED FOR 3D PRINTING
31
32. document version 181120 for smop version 2.14.2
3. SUPPORTED INDICATIONS – FULLY EDENTULOUS
Courtesy of Dental Clinic, Lucerne
Copyright 2018, Dr. med. Beat Kurt
32
33. document version 181120 for smop version 2.14.2
3. SUPPORTED INDICATIONS – FULLY EDENTULOUS – ALL ON FOUR
Courtesy of Dental Clinic, Lucerne
Copyright 2018, Dr. med. Beat Kurt
33
34. document version 181120 for smop version 2.14.2
3. SUPPORTED INDICATIONS – PARTIAL EDENTULOUS
Courtesy of Dental Clinic, Lucerne
Copyright 2018, Dr. med. Beat Kurt
34
35. document version 181120 for smop version 2.14.2
3. SUPPORTED INDICATIONS – TOOTH GAP
Courtesy of Dental Clinic, Lucerne
Copyright 2018, Dr. med. Beat Kurt
35
36. document version 181120 for smop version 2.14.2
smop for STANDARD USER
Standard User can create cases and do all case preparation and implant planning himself. He can order any planning
and template design by their Service Partner.
Condition: The Standard User is connected to the Service Partner he registered with.
smop for BASIC USER
Basic Users can create cases and order any case planning and template design. Case preparation, template design and
printing are provided by the Service Partner. Beside case creation, the Basic User has the option to plan implants or
adjust any provided implant planning.
Condition: The Basic User is connected to the Service Partner he registered with.
smop for CHAIR SIDE USER
Chair Side User can create cases, do all case preparation, implant planning and template design.
Condition: The Chair Side User has the option to be connected to any smop Print Partner, to order printouts
4. PRODUCT CONFIGURATIONS for different user needs
smop MOBILE VIEWER (for iPad and iPhone)
For Approval of implant planning and template design
Condition: The Basic User is connected to the Service Partner he registered with.
36
37. document version 181120 for smop version 2.14.2
BASIC USER
STANDARD USER
CHAIR SIDE USER
Im
portDataOrderFullService
Im
port/Plan
W
ax-up
Prepare
Case
Plan
Im
plants
OrderTem
plateDesign
Tem
plate
Im
port/Align
Model
ExportData
1 2 3 4 5 6 7
4. SMOP WORKFLOW
37
Falsche Richtung des Modells Modell muss okklusal ausgerichtet sein um dann die Unterschnitte zu kriegen, so hat es keine Logik dann würde ich die Toolleiste vergrössert darstellen
<number>
Hier das Selbe Toolleiste gross oder Pfeil auf das entsprechende Icon
<number>
Hier stört mich die Hintergrundsfarbe weniger da eigenes Modul
<number>
Hinweis gut, würde aber automatically und available weglassen und dazu schreiben, : kann geändert werden
<number>
Schiene muss unbedingt gelb sein !!!
<number>
<number>
Weglassen oder an anderer Stelle
<number>
<number>
<number>
<number>
<number>
Schienen wieder gelb
<number>
<number>
Schienen gelb
<number>
Jetzt eine weitere Folie einfügen zeigen, das man auch Generische Implantate verwenden kann
<number>
Weiteres Bild mit dem Export Button für Schiene machen mit aÂuswahl für Drucker
<number>