SlideShare une entreprise Scribd logo
1  sur  6
Télécharger pour lire hors ligne
Zareba Sensepoint Pro
Comprehensive monitoring of
flammable, toxic and oxygen
gas hazards in potentially
explosive atmospheres
The Sensepoint Pro provides
comprehensive monitoring of flammable,
toxic and oxygen gas hazards in potentially
explosive atmospheres, both in and out of
doors. Users can modify detector operation
using the remote control provided without
ever needing to open the unit. This enables
one man, non-intrusive, operation and
reduces routine maintenance time and costs.
All detectors are supplied pre-configured and
include two programmable alarm relays as well
as an industry standard 4-20mA output.
The scale, range, calibration, relay operation
and alarm set points of the detector may all be
adjusted via the transmitters’ backlit LCD and
an intrinsically safe remote control that is also
suitable for use in potentially explosive
atmospheres. Outputs are automatically
inhibited during adjustment thereby reducing
the risk of false alarm at the control panel
during maintenance.
Sensepoint Pro is supplied with all necessary
accessories for easy installation. The detector
can be mounted on a wall or round support
pole using the universal bracket provided.
The detector is ideal for use with either conduit
or steel wire armored cable and glands.
A 3/4”NPT entry and M20 adaptor are
included as standard. A weatherproof cap is
also included for use in the harshest outdoor
conditions.
Overall, the Sensepoint Pro ensures easy
installation and the fastest routine operation by
removing the need for hot work permits in
hazardous areas. Using an easy to replace
plug-in sensor, downtime is also reduced and
on-going costs are minimized through the use
of poison resistant flammable sensors and
patented Surecell
TM
toxic sensor technology.
Sensepoint Pro meets the more demanding
user requirements but assures you of the most
cost effective solution to your gas detection
needs in the long run.
One-Stop Shop
• Flammable, toxic and oxygen versions
available
• Suitable for indoor or outdoor use
• IP65 as standard
Proven Sensor Technology
• SurecellTM
electrochemical sensors
• Poison resistant catalytic bead
• Fast and reliable
• Typical 2 to 5 years operational life
Global Certifications*
• US, Canada and Europe
• Compliant with UL, CSA and ATEX
standards
• Includes hazardous area AND
performance approval
Convenient to Use
• Backlit LCD for dark environments
• Fully configurable via IR remote control
• 4-20mA and relay operation
• Auto-inhibit during maintenance
Cost Effective
• Minimal training required
• Non-intrusive, one-man operation
• Plug-in sensor replacement
• All necessary accessories included
Friendly Installation
• Universal mounting bracket
• 3⁄4” NPT and M20 entries included
as standard
• Suitable for conduit or SWA cable/
glands installations
Range of Accessories
• Flow adaptor
• Duct mounting kit
• Collecting cone
*Pending - Contact Honeywell Analytics for more
information
Sensepoint Pro
Installation Details
Installation Details
Sensepoint Pro is designed for use in potentially
explosive atmospheres. As such, installation
should follow national guidelines using suitably
approved steel wire armored cable and glands
(M20 or 3/4”NPT) or conduit (3/4”NPT).
Use 0.5mm2
(20AWG) to 2.5mm
2
(14AWG)
cross sectional area cable, as needed to ensure
minimum operating voltage at the detector,
depending upon installed cable length.
Various accessories are available for different
applications.
Poie Mount Wall Mount
Duct Mount Collecting Cone
Dimensions
Electrical Connections
150.0mm / 5.9"
150.0mm / 5.9"
36.0mm
36.0mm /
/
1.4"
1.4"
102.0mm / 4.0"
102.0mm / 4.0"
"
"
1
1
.
.
4
4
/
/
m
m
m
m
m
m
mm
m
0
0
.
.
4
4
0
0
4
4
04
4
1
1
20.0-80.0mm
20.0-80.0mm
20.0-80.0mm
20.0-80.0mm /
/
0.8"-3.2"
0.8"-3.2"
0.8"-3.2"
0.8"-3.2"
"
"
2
2
.
.
4
4
/
/
m
m
m
m
m
m
mm
m
0
0
.
.
7
7
0
0
1
1
"
"
3
3
.
.
7
7
/
/
m
m
m
m
m
m
mm
m
0
0
.
.
6
6
8
8
1
1
"
"
"
"
2
2
2
2
.
.
3
3
3
3
/
/
/
/
m
m
m
m
m
m
mm
m
0
0
0
0
.
.
0
0
0
0
8
8
8
8
Technical Summary
General Specification
Use 3 wire, 4-20mA, fixed point gas detector with built in alarm relays for the protection
of personnel and plant from flammable, toxic and oxygen gas hazards. Incorporating
transmitter with local display and fully configurable via remote handheld control
Detectable Gases
Gas Measuring Range Operating Temperature*
Ident Name 1#
2 3 Min Max
F Flammable 0-100% LEL -20°C / -4°F 50°C / 122°F
O Oxygen 0-25% VOL -15°C / 5°F 40°C / 104°F
C Carbon Monoxide
+
0-200ppm 0-500ppm -20°C / -4°F 50°C / 122°F
H Hydrogen Sulfide
+
0-50ppm 0-20ppm 0-100ppm -20°C / -4°F 50°C / 122°F
G Hydrogen 0-1000ppm -5°C / 23°F 40°C / 104°F
+
SurecellTM
Sensor Technology #
Standard range *Check certified temperature
Electrical
General 3 wire connection, 12-30Vdc, 4-20mA (source), common 0Vdc
7 x screw terminals for O.5mm2
(20AWG) to 2.5mm2
(14AWG) wire
Maximum operating current: 300mA (flammable), 150mA (toxic and oxygen)
Maximum peak in rush current: 600mA
Signal 22mA Maximum over range
4-20mA Normal operation: 0-100% full scale
2mA or 4mA Output inhibited (2mA or 17.4mA for oxygen)
0mA Fault
Alarm Relays 2 x 3A@240Vac alarm relays
User configurable alarm trip point, normally energized/de-energized operation
Link selectable output as NO or NC
Construction
Material Main body: Powder coated aluminum (ADC12)
Sensor: 316 stainless steel
Weatherproof cap: Aluminum, 316 stainless steel mesh
Weight 1450g
Certification Sensepoint Pro Sensepoint Pro Remote Control ZHC1
ATEX Ex II 2G EEx d IIC T4 Ex II 2G EEx ib IIC T4
(Tamb = -20°C to +50°C / -4°F to +122°F) (Tamb = -20°C to +50°C / -4°F to +122°F)
UL Class 1, Div 1, Groups B, C, D Class 1, Div 1, Groups A, B, C, D
(Tamb = -20°C to +50°C / -4°F to +122°F) (Tamb = -20°C to +50°C / -4°F to +122°F)
Applicable Standards North America: UL1203
Europe: CE, ATEX, EMC (EN50270)
Contact Honeywell Analytics for latest information
Environmental
IP Rating IP65 as standard in accordance with EN60529:1992
Operating Temperature Dependent upon gas type and certification
Operating Humidity Range Continuous: 20-90%RH (non condensing), Intermittent: 10-99%RH (non condensing)
Operating Pressure 90-110kPa
Storage Conditions Instrument -40°C to +50°C (-40°F to +122°F)
* Oxygen detection products must only be used to detect oxygen depletion in air.
Ordering Information
Ordering Information
Standard Supply
Each detector is supplied complete with IS remote control, 3⁄4”NPT entry, 3⁄4”NPT to M20
adaptor, wall mounting bracket, pole mounting bracket, weatherproof cap, necessary Allen
keys and instruction manual all sealed in a plastic bag inside a shipping carton
Shipping Details
Shipping carton dimensions: L312mm (12.3”) x W223mm (8.8”) x D110mm (4.3”)
Approximate weight: 1.5Kg (3.3llbs)
Optional Accessories
SPPPCC Collecting cone
SPPPCAL Flow adaptor
SPPPDM Duct mounting kit
Calibration Equipment
Contact Honeywell Analytics Representative
STANDARDS
U USA (UL)
A Europe (ATEX)
RANGE
1 Refer to
2 Detectable Gases
3 Table Above
e.g. SP PR U X F 1 = SPPRUXF1
GAS TYPE
F Flammable
O Oxygen
C Carbon Monoxide
H Hydrogen Sulfide
G Hydrogen
}
H_Sensepoint Pro_DS0328_V1
12/05
© 2005 Honeywell Analytics
11078
Find out more
www.honeywellanalytics.com
Customer business centre
Europe and the rest of the world
Honeywell Analytics AG
Wilstrasse 11-U11
CH-8610 Uster
Switzerland
Tel: +41 (0)44 943 4300
Fax: +41 (0)44 943 4398
sales@zelana.co.uk
Customer business center
Americas
Honeywell Analytics Distribution, Inc.
400 Sawgrass Corporate Pkwy
Suite 100
Sunrise, FL 33325
USA
Tel: +1 954 514 2700
Toll free: +1 800 538 0363
Fax: +1 954 514 2784
sales@zelana.com
www.honeywell.com
As World leaders in gas detection solutions, Honeywell Analytics’
Zareba range of gas detection systems has been designed to
provide efficient, practical and cost-effective equipment to protect
people from a variety of forms of hazardous gas. The equipment
is also simple to install and easy to operate and maintain.
Sensepoint Sensepoint Plus Sensepoint Pro
The Zareba range of fixed gas detection
Touchpoint 1 Touchpoint 4
Metro Metro controller
Sensepoint range
Designed for industrial use, the Sensepoint range provides an easy
way of ensuring legislative requirements are met.
Touchpoint
Designed for industrial use, the Touchpoint range provides an easy
way of ensuring legislative requirements are met. It is particularly
suited where a number of small, discrete, stand-alone systems
are required.
Metro
For commercial environments such as car parks, municipal
buildings and retail facilities, Metro offers a fully programmable,
addressable gas detection system.
Unipoint
Unipoint is a simple DIN rail mounted controller offering integrators
a flexible and low cost solution to incorporate flammable, toxic or
oxygen gas detection into their control systems. From car parks
and boiler houses to analyzer shelters or crane cabs in
offshore facilities.
Please Note:
While every effort has been made to ensure
accuracy in this publication, no responsibility
can be accepted for errors or omissions.
Data may change, as well as legislation, and you
are strongly advised to obtain copies of the most
recently issued regulations, standards, and guidelines.
This publication is not intended to form the
basis of a contract.
© 2005 Honeywell Analytics

Contenu connexe

Similaire à Sensepoint_Pro_pdf.pdf

Dräger Multi-PID 2 Portable Gas Detector - Spec Sheet
Dräger Multi-PID 2  Portable Gas Detector - Spec SheetDräger Multi-PID 2  Portable Gas Detector - Spec Sheet
Dräger Multi-PID 2 Portable Gas Detector - Spec Sheet
Thorne & Derrick UK
 
Crowcon Clip Portable Gas Detector
Crowcon Clip Portable Gas DetectorCrowcon Clip Portable Gas Detector
Crowcon Clip Portable Gas Detector
Thorne & Derrick UK
 
Williamson Infrared Products for Monitoring Smokeless Flares, Pilots, and Fla...
Williamson Infrared Products for Monitoring Smokeless Flares, Pilots, and Fla...Williamson Infrared Products for Monitoring Smokeless Flares, Pilots, and Fla...
Williamson Infrared Products for Monitoring Smokeless Flares, Pilots, and Fla...
Hile Controls of Alabama, Inc.
 
Crowcon Tetra 3 (T3) Portable Gas Detector
Crowcon Tetra 3 (T3) Portable Gas DetectorCrowcon Tetra 3 (T3) Portable Gas Detector
Crowcon Tetra 3 (T3) Portable Gas Detector
Thorne & Derrick UK
 
Crowcon F-Gas Fixed Gas Detector - Spec Sheet
Crowcon F-Gas Fixed Gas Detector - Spec SheetCrowcon F-Gas Fixed Gas Detector - Spec Sheet
Crowcon F-Gas Fixed Gas Detector - Spec Sheet
Thorne & Derrick UK
 
VEGA Guided Wave Radar VEGAFLEX series 80
VEGA Guided Wave Radar VEGAFLEX series 80VEGA Guided Wave Radar VEGAFLEX series 80
VEGA Guided Wave Radar VEGAFLEX series 80
Thorne & Derrick UK
 

Similaire à Sensepoint_Pro_pdf.pdf (20)

Dräger Multi-PID 2 Portable Gas Detector - Spec Sheet
Dräger Multi-PID 2  Portable Gas Detector - Spec SheetDräger Multi-PID 2  Portable Gas Detector - Spec Sheet
Dräger Multi-PID 2 Portable Gas Detector - Spec Sheet
 
Crowcon Clip Portable Gas Detector
Crowcon Clip Portable Gas DetectorCrowcon Clip Portable Gas Detector
Crowcon Clip Portable Gas Detector
 
Continuous Emissions Monitoring
Continuous Emissions MonitoringContinuous Emissions Monitoring
Continuous Emissions Monitoring
 
Edwards Signaling SD-VTK Data Sheet
Edwards Signaling SD-VTK Data SheetEdwards Signaling SD-VTK Data Sheet
Edwards Signaling SD-VTK Data Sheet
 
Edwards Signaling SD-PH Data Sheet
Edwards Signaling SD-PH Data SheetEdwards Signaling SD-PH Data Sheet
Edwards Signaling SD-PH Data Sheet
 
Edwards Signaling SD-GSK Data Sheet
Edwards Signaling SD-GSK Data SheetEdwards Signaling SD-GSK Data Sheet
Edwards Signaling SD-GSK Data Sheet
 
Edwards Signaling SD2W Data Sheet
Edwards Signaling SD2W Data SheetEdwards Signaling SD2W Data Sheet
Edwards Signaling SD2W Data Sheet
 
Drager Polytron IR CO2 Fixed Gas Detector - Spec Sheet
Drager Polytron IR CO2 Fixed Gas Detector - Spec SheetDrager Polytron IR CO2 Fixed Gas Detector - Spec Sheet
Drager Polytron IR CO2 Fixed Gas Detector - Spec Sheet
 
Drager Polytron 5700 Fixed Gas Detector - Spec Sheet
Drager Polytron 5700 Fixed Gas Detector - Spec SheetDrager Polytron 5700 Fixed Gas Detector - Spec Sheet
Drager Polytron 5700 Fixed Gas Detector - Spec Sheet
 
Orbipac cpf81 cpf81 d_cpf82_cpf82d-endress+hauser datasheet-ph sensor
Orbipac cpf81 cpf81 d_cpf82_cpf82d-endress+hauser datasheet-ph sensorOrbipac cpf81 cpf81 d_cpf82_cpf82d-endress+hauser datasheet-ph sensor
Orbipac cpf81 cpf81 d_cpf82_cpf82d-endress+hauser datasheet-ph sensor
 
Williamson Infrared Products for Monitoring Smokeless Flares, Pilots, and Fla...
Williamson Infrared Products for Monitoring Smokeless Flares, Pilots, and Fla...Williamson Infrared Products for Monitoring Smokeless Flares, Pilots, and Fla...
Williamson Infrared Products for Monitoring Smokeless Flares, Pilots, and Fla...
 
Drager Polytron 5000 Fixed Gas Detector - Spec Sheet
Drager Polytron 5000 Fixed Gas Detector - Spec SheetDrager Polytron 5000 Fixed Gas Detector - Spec Sheet
Drager Polytron 5000 Fixed Gas Detector - Spec Sheet
 
Mm500 Moisture Analysers
Mm500 Moisture AnalysersMm500 Moisture Analysers
Mm500 Moisture Analysers
 
Crowcon Portable Gas Detectors
Crowcon Portable Gas DetectorsCrowcon Portable Gas Detectors
Crowcon Portable Gas Detectors
 
Crowcon Tetra 3 (T3) Portable Gas Detector
Crowcon Tetra 3 (T3) Portable Gas DetectorCrowcon Tetra 3 (T3) Portable Gas Detector
Crowcon Tetra 3 (T3) Portable Gas Detector
 
Orbisint cps11 cps11 d-endress+hauser datasheet-ph electrodes
Orbisint cps11 cps11 d-endress+hauser datasheet-ph electrodesOrbisint cps11 cps11 d-endress+hauser datasheet-ph electrodes
Orbisint cps11 cps11 d-endress+hauser datasheet-ph electrodes
 
Crowcon F-Gas Fixed Gas Detector - Spec Sheet
Crowcon F-Gas Fixed Gas Detector - Spec SheetCrowcon F-Gas Fixed Gas Detector - Spec Sheet
Crowcon F-Gas Fixed Gas Detector - Spec Sheet
 
VEGA Guided Wave Radar VEGAFLEX series 80
VEGA Guided Wave Radar VEGAFLEX series 80VEGA Guided Wave Radar VEGAFLEX series 80
VEGA Guided Wave Radar VEGAFLEX series 80
 
AMETEK Drexelbrook Safety IntelliPoint SIL2.
AMETEK Drexelbrook Safety IntelliPoint SIL2.AMETEK Drexelbrook Safety IntelliPoint SIL2.
AMETEK Drexelbrook Safety IntelliPoint SIL2.
 
D4120
D4120D4120
D4120
 

Dernier

Hospital management system project report.pdf
Hospital management system project report.pdfHospital management system project report.pdf
Hospital management system project report.pdf
Kamal Acharya
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
ssuser89054b
 
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak HamilCara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Kandungan 087776558899
 
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
9953056974 Low Rate Call Girls In Saket, Delhi NCR
 

Dernier (20)

Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best ServiceTamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
 
AIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech studentsAIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech students
 
A Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna MunicipalityA Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna Municipality
 
Thermal Engineering Unit - I & II . ppt
Thermal Engineering  Unit - I & II . pptThermal Engineering  Unit - I & II . ppt
Thermal Engineering Unit - I & II . ppt
 
Hospital management system project report.pdf
Hospital management system project report.pdfHospital management system project report.pdf
Hospital management system project report.pdf
 
Online electricity billing project report..pdf
Online electricity billing project report..pdfOnline electricity billing project report..pdf
Online electricity billing project report..pdf
 
Online food ordering system project report.pdf
Online food ordering system project report.pdfOnline food ordering system project report.pdf
Online food ordering system project report.pdf
 
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
 
Introduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaIntroduction to Serverless with AWS Lambda
Introduction to Serverless with AWS Lambda
 
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced LoadsFEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
 
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptxOrlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
 
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptxHOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
 
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak HamilCara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
 
Computer Lecture 01.pptxIntroduction to Computers
Computer Lecture 01.pptxIntroduction to ComputersComputer Lecture 01.pptxIntroduction to Computers
Computer Lecture 01.pptxIntroduction to Computers
 
Double Revolving field theory-how the rotor develops torque
Double Revolving field theory-how the rotor develops torqueDouble Revolving field theory-how the rotor develops torque
Double Revolving field theory-how the rotor develops torque
 
Work-Permit-Receiver-in-Saudi-Aramco.pptx
Work-Permit-Receiver-in-Saudi-Aramco.pptxWork-Permit-Receiver-in-Saudi-Aramco.pptx
Work-Permit-Receiver-in-Saudi-Aramco.pptx
 
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
 
kiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal loadkiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal load
 
Engineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planesEngineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planes
 

Sensepoint_Pro_pdf.pdf

  • 1. Zareba Sensepoint Pro Comprehensive monitoring of flammable, toxic and oxygen gas hazards in potentially explosive atmospheres
  • 2. The Sensepoint Pro provides comprehensive monitoring of flammable, toxic and oxygen gas hazards in potentially explosive atmospheres, both in and out of doors. Users can modify detector operation using the remote control provided without ever needing to open the unit. This enables one man, non-intrusive, operation and reduces routine maintenance time and costs. All detectors are supplied pre-configured and include two programmable alarm relays as well as an industry standard 4-20mA output. The scale, range, calibration, relay operation and alarm set points of the detector may all be adjusted via the transmitters’ backlit LCD and an intrinsically safe remote control that is also suitable for use in potentially explosive atmospheres. Outputs are automatically inhibited during adjustment thereby reducing the risk of false alarm at the control panel during maintenance. Sensepoint Pro is supplied with all necessary accessories for easy installation. The detector can be mounted on a wall or round support pole using the universal bracket provided. The detector is ideal for use with either conduit or steel wire armored cable and glands. A 3/4”NPT entry and M20 adaptor are included as standard. A weatherproof cap is also included for use in the harshest outdoor conditions. Overall, the Sensepoint Pro ensures easy installation and the fastest routine operation by removing the need for hot work permits in hazardous areas. Using an easy to replace plug-in sensor, downtime is also reduced and on-going costs are minimized through the use of poison resistant flammable sensors and patented Surecell TM toxic sensor technology. Sensepoint Pro meets the more demanding user requirements but assures you of the most cost effective solution to your gas detection needs in the long run. One-Stop Shop • Flammable, toxic and oxygen versions available • Suitable for indoor or outdoor use • IP65 as standard Proven Sensor Technology • SurecellTM electrochemical sensors • Poison resistant catalytic bead • Fast and reliable • Typical 2 to 5 years operational life Global Certifications* • US, Canada and Europe • Compliant with UL, CSA and ATEX standards • Includes hazardous area AND performance approval Convenient to Use • Backlit LCD for dark environments • Fully configurable via IR remote control • 4-20mA and relay operation • Auto-inhibit during maintenance Cost Effective • Minimal training required • Non-intrusive, one-man operation • Plug-in sensor replacement • All necessary accessories included Friendly Installation • Universal mounting bracket • 3⁄4” NPT and M20 entries included as standard • Suitable for conduit or SWA cable/ glands installations Range of Accessories • Flow adaptor • Duct mounting kit • Collecting cone *Pending - Contact Honeywell Analytics for more information Sensepoint Pro
  • 3. Installation Details Installation Details Sensepoint Pro is designed for use in potentially explosive atmospheres. As such, installation should follow national guidelines using suitably approved steel wire armored cable and glands (M20 or 3/4”NPT) or conduit (3/4”NPT). Use 0.5mm2 (20AWG) to 2.5mm 2 (14AWG) cross sectional area cable, as needed to ensure minimum operating voltage at the detector, depending upon installed cable length. Various accessories are available for different applications. Poie Mount Wall Mount Duct Mount Collecting Cone Dimensions Electrical Connections 150.0mm / 5.9" 150.0mm / 5.9" 36.0mm 36.0mm / / 1.4" 1.4" 102.0mm / 4.0" 102.0mm / 4.0" " " 1 1 . . 4 4 / / m m m m m m mm m 0 0 . . 4 4 0 0 4 4 04 4 1 1 20.0-80.0mm 20.0-80.0mm 20.0-80.0mm 20.0-80.0mm / / 0.8"-3.2" 0.8"-3.2" 0.8"-3.2" 0.8"-3.2" " " 2 2 . . 4 4 / / m m m m m m mm m 0 0 . . 7 7 0 0 1 1 " " 3 3 . . 7 7 / / m m m m m m mm m 0 0 . . 6 6 8 8 1 1 " " " " 2 2 2 2 . . 3 3 3 3 / / / / m m m m m m mm m 0 0 0 0 . . 0 0 0 0 8 8 8 8
  • 4. Technical Summary General Specification Use 3 wire, 4-20mA, fixed point gas detector with built in alarm relays for the protection of personnel and plant from flammable, toxic and oxygen gas hazards. Incorporating transmitter with local display and fully configurable via remote handheld control Detectable Gases Gas Measuring Range Operating Temperature* Ident Name 1# 2 3 Min Max F Flammable 0-100% LEL -20°C / -4°F 50°C / 122°F O Oxygen 0-25% VOL -15°C / 5°F 40°C / 104°F C Carbon Monoxide + 0-200ppm 0-500ppm -20°C / -4°F 50°C / 122°F H Hydrogen Sulfide + 0-50ppm 0-20ppm 0-100ppm -20°C / -4°F 50°C / 122°F G Hydrogen 0-1000ppm -5°C / 23°F 40°C / 104°F + SurecellTM Sensor Technology # Standard range *Check certified temperature Electrical General 3 wire connection, 12-30Vdc, 4-20mA (source), common 0Vdc 7 x screw terminals for O.5mm2 (20AWG) to 2.5mm2 (14AWG) wire Maximum operating current: 300mA (flammable), 150mA (toxic and oxygen) Maximum peak in rush current: 600mA Signal 22mA Maximum over range 4-20mA Normal operation: 0-100% full scale 2mA or 4mA Output inhibited (2mA or 17.4mA for oxygen) 0mA Fault Alarm Relays 2 x 3A@240Vac alarm relays User configurable alarm trip point, normally energized/de-energized operation Link selectable output as NO or NC Construction Material Main body: Powder coated aluminum (ADC12) Sensor: 316 stainless steel Weatherproof cap: Aluminum, 316 stainless steel mesh Weight 1450g Certification Sensepoint Pro Sensepoint Pro Remote Control ZHC1 ATEX Ex II 2G EEx d IIC T4 Ex II 2G EEx ib IIC T4 (Tamb = -20°C to +50°C / -4°F to +122°F) (Tamb = -20°C to +50°C / -4°F to +122°F) UL Class 1, Div 1, Groups B, C, D Class 1, Div 1, Groups A, B, C, D (Tamb = -20°C to +50°C / -4°F to +122°F) (Tamb = -20°C to +50°C / -4°F to +122°F) Applicable Standards North America: UL1203 Europe: CE, ATEX, EMC (EN50270) Contact Honeywell Analytics for latest information Environmental IP Rating IP65 as standard in accordance with EN60529:1992 Operating Temperature Dependent upon gas type and certification Operating Humidity Range Continuous: 20-90%RH (non condensing), Intermittent: 10-99%RH (non condensing) Operating Pressure 90-110kPa Storage Conditions Instrument -40°C to +50°C (-40°F to +122°F) * Oxygen detection products must only be used to detect oxygen depletion in air.
  • 5. Ordering Information Ordering Information Standard Supply Each detector is supplied complete with IS remote control, 3⁄4”NPT entry, 3⁄4”NPT to M20 adaptor, wall mounting bracket, pole mounting bracket, weatherproof cap, necessary Allen keys and instruction manual all sealed in a plastic bag inside a shipping carton Shipping Details Shipping carton dimensions: L312mm (12.3”) x W223mm (8.8”) x D110mm (4.3”) Approximate weight: 1.5Kg (3.3llbs) Optional Accessories SPPPCC Collecting cone SPPPCAL Flow adaptor SPPPDM Duct mounting kit Calibration Equipment Contact Honeywell Analytics Representative STANDARDS U USA (UL) A Europe (ATEX) RANGE 1 Refer to 2 Detectable Gases 3 Table Above e.g. SP PR U X F 1 = SPPRUXF1 GAS TYPE F Flammable O Oxygen C Carbon Monoxide H Hydrogen Sulfide G Hydrogen }
  • 6. H_Sensepoint Pro_DS0328_V1 12/05 © 2005 Honeywell Analytics 11078 Find out more www.honeywellanalytics.com Customer business centre Europe and the rest of the world Honeywell Analytics AG Wilstrasse 11-U11 CH-8610 Uster Switzerland Tel: +41 (0)44 943 4300 Fax: +41 (0)44 943 4398 sales@zelana.co.uk Customer business center Americas Honeywell Analytics Distribution, Inc. 400 Sawgrass Corporate Pkwy Suite 100 Sunrise, FL 33325 USA Tel: +1 954 514 2700 Toll free: +1 800 538 0363 Fax: +1 954 514 2784 sales@zelana.com www.honeywell.com As World leaders in gas detection solutions, Honeywell Analytics’ Zareba range of gas detection systems has been designed to provide efficient, practical and cost-effective equipment to protect people from a variety of forms of hazardous gas. The equipment is also simple to install and easy to operate and maintain. Sensepoint Sensepoint Plus Sensepoint Pro The Zareba range of fixed gas detection Touchpoint 1 Touchpoint 4 Metro Metro controller Sensepoint range Designed for industrial use, the Sensepoint range provides an easy way of ensuring legislative requirements are met. Touchpoint Designed for industrial use, the Touchpoint range provides an easy way of ensuring legislative requirements are met. It is particularly suited where a number of small, discrete, stand-alone systems are required. Metro For commercial environments such as car parks, municipal buildings and retail facilities, Metro offers a fully programmable, addressable gas detection system. Unipoint Unipoint is a simple DIN rail mounted controller offering integrators a flexible and low cost solution to incorporate flammable, toxic or oxygen gas detection into their control systems. From car parks and boiler houses to analyzer shelters or crane cabs in offshore facilities. Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract. © 2005 Honeywell Analytics