ESDEP WG 15 
STRUCTURAL SYSTEMS: MISCELLANEOUS 
Lecture 15C.1: Design of Tanks for the 
Storage of Oil and Water 
OBJECTIVE/SCOPE: 
The lecture describes the basic principles used in the design of tanks for the storage of 
oil or water. It covers the design of vertical cylindrical tanks, and reference is made to 
the British Standard BS 2654 [1] and to the American Petroleum Industry Standard 
API650 [2]. 
PREREQUISITES 
None. 
RELATED LECTURES 
Lecture 8.6: Introduction to Shell Structures 
Lecture 8.8: Design of Unstiffened Cylinders 
SUMMARY 
Welded cylindrical tanks are commonly used to store oil products or water. 
The principal structural element of these tanks is a vertical steel cylinder, or shell, 
which is made by welding together a series of rectangular plates and which restrains 
the hydrostatic pressures by hoop tension forces. The tank is normally provided with a 
flat steel plated bottom which sits on a prepared foundation, and with a fixed roof 
attached to the top of the shell wall. 
This lecture explains the design basis for the structural elements of cylindrical tanks 
and illustrates the arrangements and the key details involved. 
1. DESIGN OF WELDED CYLINDRICAL TANKS
1.1 General 
Oil and oil products are most commonly stored in cylindrical steel tanks at 
atmospheric pressure or at low pressure. The tanks are flat bottomed and are provided 
with a roof which is of conical or domed shape. 
Water is also sometimes stored in cylindrical steel tanks. When used to store potable 
water they are of a size suitable to act as a service reservoir for a local community; 
they have a roof to prevent contamination of the water. Cylindrical tanks are also used 
in sewage treatment works for settlement and holding tanks; they are usually without 
a roof. 
The sizes of cylindrical tanks range from a modest 3m diameter up to about 100m 
diameter, and up to 25m in height. They consist of three principal structural elements - 
bottom, shell and roof. 
For petroleum storage, the bottom is formed of steel sheets, laid on a prepared base. 
Some tanks for water storage use a reinforced concrete slab as the base of the tank, 
instead of steel sheets. 
The shell, or cylindrical wall, is made up of steel sheets and is largely unstiffened. 
The roof of the tank is usually fixed to the top of the shell, though floating roofs are 
provided in some circumstances. A fixed roof may be self supporting or partially 
supported through membrane action, though generally the roof plate is supported on 
radial beams or trusses. 
1.2 Design Standards 
Clearly, common standards are generally applicable whether a tank holds oil or water, 
though it is the petroleum industry which has been responsible for the development of 
many of the design procedures and standards. 
The two standards applied most widely are British Standard BS 2654 [1] and the 
American Petroleum Institute Standard API 650 [2]. These two Standards have much 
in common, although there are some significant differences (see Appendix A). Other 
standards, American and European, are not applied much outside their respective 
countries. 
This lecture will generally follow the requirements of BS 2654 [1]. This standard is 
both a design code and a construction specification. The design code is based on 
allowable stress principles, not on a limit state basis.
1.3 Design Pressure and Temperature 
Tanks designed for storage at nominally atmospheric pressure must be suitable for 
modest internal vacuum (negative pressure). Tanks may also be designed to work at 
relatively small positive internal pressures (up to 56 mbar (5,6 kN/m2), according to 
BS2654. 
Non-refrigerated tanks are designed for a minimum metal temperature which is based 
on the lowest ambient air temperature (typically, ambient plus 10oC) or the lowest 
temperature of the contents, whichever is the lower. No maximum service temperature 
is normally specified. 
1.4 Material 
Tanks are usually manufactured from plain carbon steel plate (traditionally referred to 
as mild steel) of grades S235 or S275 (to EN 10 025 [3]), or equivalent. Such material 
is readily weldable. The use of higher strength grades of low alloy steel (e.g. Grade 
S355) is less common, though its use is developing. 
Notch ductility at the lowest service temperature is obtained for thicker materials (> 
13 mm) by specifying minimum requirements for impact tests. This is normally 
achieved by specifying an appropriate sub-grade to EN 10 025 [3]. 
Internally, oil tanks are normally unpainted. Water tanks may be given a coating 
(provided it is suitably inert, where the water is potable), or may be given cathodic 
protection. Externally, tanks are normally protected. Where any steel is used 
uncoated, an allowance must be made in the design for loss of thickness due to 
corrosion. 
2. DESIGN LOADING 
A tank is designed for the most severe combination of the various possible loadings. 
2.1 Dead Load 
The dead load is that due to the weight of all the parts of the tank. 
2.2 Superimposed Load 
A minimum superimposed load of 1,2 kN/m2 (over the horizontal projected area) is 
applied to the roof of the tank. This load is commonly known as the 'snow load', but in 
fact represents, as well as a nominal snow load, any other imposed loads, such as
maintenance equipment, which might be applied to the roof, and it includes the 
internal vacuum load. It is therefore applicable even in locations where snow is not 
experienced. 
Non-pressure tanks are often fitted with valves which do not open until the vacuum 
reaches a value of 2,5 mbar, to contain vapour losses. By the time a valve is fully 
open, a vacuum of 5 mbar (0,5 kN/m2) may have developed. Even without valves a 
tank should be designed for a vacuum of 5 mbar, to cater for differential pressure 
under wind loads. In pressure tanks the valves may be set to 6 mbar vacuum, in which 
case a pressure difference of 8,5 mbar (0,85 kN/m2) may develop. 
Actual predicted snow load or other superimposed load, plus appropriate vacuum 
pressure, should be used when it is greater than the specified minimum. 
2.3 Contents 
The weight and hydrostatic pressure of the contents, up to the full capacity of the tank, 
should be applied. Full capacity is usually determined by an overflow near the top of 
the tank; for a tank without any overflow, the contents should be taken to fill the tank 
to the top of the shell. 
For oil and oil products, the relative density of the contents is less than 1.0, but tanks 
for such liquids are normally tested by filling with water. A density of 1000 
kg/m3 should therefore be taken as a minimum. 
2.4 Wind Loads 
Wind loads are determined on the basis of a design wind speed. Maximum wind speed 
depends on the area in which the tank is to be built; typically a value of 45 m/s is 
taken as the design wind speed, representing the maximum 3-second gust speed which 
is exceeded, on average, only once every 50 years. 
2.5 Seismic Loads 
In some areas, a tank must be designed to withstand seismic loads. Whilst some 
guidance is given in BS 2654 [1] and API650 [2] on the design of the tank, specialised 
knowledge should be applied in determining seismic loads. 
3. BOTTOM DESIGN 
For petroleum storage tanks, steel bottom plates are specified, laid and fully supported 
on a prepared foundation.
The steel plates are directly supported on a bitumen-sand layer on top of a foundation, 
usually of compacted fill or, if the subsoil is weak, possibly a reinforced concrete raft. 
A typical foundation pad is shown in Figure 1 and a detailed description of the 
formation of this example is given in Appendix A of BS 2654 [1]. 
The bottom is made up of a number of rectangular plates, surrounded by a set of 
shaped plates, called sketch plates, to give a circular shape, as shown in Figure 2. The 
plates slightly overlap each other and are pressed locally at the corners where three 
plates meet (see Figure 3). Lapped and fillet welded joints are preferred to butt welded 
joints (which must be welded onto a backing strip below the joint) because they are 
easier and cheaper to make.
For larger tanks (over 12,5 m diameter, according to BS 2654) a ring of annular plates 
is provided around the group of rectangular plates. The radial joints between the 
annular plates are butt welded, rather than lapped, because of the ring stiffening which 
the plates provide to the bottom of the shell. A typical arrangement is shown in Figure 
4.
The shell sits on the sketch or annular plates, just inside the perimeter and is fillet 
welded to them (see Figure 5).
The bottom plates act principally as a seal to the tank. The only load they carry, apart 
from local stiffening to the bottom of the shell, is the pressure from the contents, 
which is then transmitted directly to the base. Stress calculations are not normally 
required for the base, though BS 2654 sets out minimum thicknesses of plate 
depending on the size of the tank. 
Water tanks may also have a steel bottom. In some circumstances a reinforced 
concrete slab is specified instead. There are no standard details for the connection 
between a shell and a concrete slab, though a simple arrangement of an angle welded 
to the bottom edge of the shell and bolted to the slab will usually suffice. 
4. SHELL DESIGN 
4.1 Circumferential Stresses 
Vertical cylinder tanks carry the hydrostatic pressures by simple hoop tension. No 
circumferential stiffening is needed for this action. The circumferential tension in the 
shell will vary directly, in a vertical direction, according to the head of fluid at any 
given level. For a uniform shell thickness, the calculation of stresses is therefore 
straightforward. At a water depth H, the stress is given by: 
where D is the diameter of the tank 
t is the thickness of the plate 
 is the density of the fluid 
g is the gravity constant 
For practical reasons, it is necessary to build up the shell from a number of fairly 
small rectangular pieces of plate, butt welded together. Each piece will be 
cylindrically curved and it is convenient to build up the shell in a number of rings, or 
courses, one on top of the other. This technique provides, at least for deeper tanks, a 
convenient opportunity to use thicker plates in the lower rings and thinner plates in the 
upper rings. 
The lowest course of plates is fully welded to the bottom plate of the tank providing 
radial restraint to the bottom edge of the plate. Similarly, the bottom edge of any
course which sits on top of a thicker course is somewhat restrained because the thicker 
plate is stiffer. The effect of this on the hoop stresses is illustrated in Figure 6. 
Consequently, because of these restraints, an empirical adjustment is introduced into 
the design rules which effectively requires that any course is simply designed for the 
pressure 300mm above the bottom edge of the course, rather than the greater pressure 
at the bottom edge. (This is known as the 'one foot rule' in API 650 [2].) 
When the load due to internal pressure is taken into account and an allowance for 
corrosion loss is introduced, the resulting design equation is of the form in BS 2654: 
where t is the calculated minimum thickness (mm) 
w is the maximum density of the fluid (kg/l)
H is the height of fluid above the bottom of the course being designed (m) 
S is the allowable design stress (N/mm2) 
p is the design pressure (pressure tanks only) (mbar) 
c is the corrosion allowance (mm) 
The allowable design stress in tension in the shell is generally taken to be a suitable 
fraction of the material yield stress. BS 2654 defines it as two-thirds of the yield 
stress, thus giving an overall factor of 1,5 on the plastic strength of the plate. API650 
also uses two-thirds of the yield stress, but additionally limits the design stress to a 
smaller fraction of the ultimate strength; for higher strength steels, this is slightly 
more restrictive. Further, API650 allows a slightly higher stress during the hydrostatic 
test than the allowable design stress for service conditions when the relative density is 
less than 1,0. 
Each course is made of a number of plates, butt welded along the vertical join 
between the plates. Each course is butt welded to the course below along a 
circumferential line. Good weld procedures can minimise the distortions or deviations 
from the ideal flat or curved line of the surface across the weld, but some imperfection 
is inevitable, especially with thin material. Consequently the rules call for the vertical 
seams to be staggered from one course to the next - at least one third of the length of 
the individual plates, if possible. 
Holes in the shell for inlet/outlet nozzles or access manholes cause a local increase in 
circumferential stresses. This increase is catered for by requiring the provision of 
reinforcing plates. These plates may take the form of a circular doubling plate welded 
around the hole or of an inset piece of thicker plate. The nozzle provides some 
stiffening to the edge of the hole; it may also be made of sufficient size that shell 
reinforcement can be omitted. 
4.2 Axial Stresses in the Shell 
The cylindrical shell has to carry its weight, and the weight of the roof which it 
supports, as an axial stress. In addition, wind loading on the tank contributes tensile 
axial stress on one side of the tank and compressive stress on the other. 
A thin-walled cylinder under a sufficient axial load will of course buckle locally, or 
wrinkle. The critical value of this stress, for a perfect cylinder, can be obtained from 
classical theory and, for steel, has the value:
In practice, imperfect shells buckle at a much lower stress; an allowable stress level of 
as little as a tenth of the above might be more appropriate. However, in normal service 
the axial stresses in shells suitable to carry the circumferential loads for the size of 
tank used for oil and water storage are much smaller than even this level of stress. The 
calculation of axial stress is therefore not even called for in codes, such as BS 2654 
and API650, for the service conditions. 
But under seismic conditions, larger stresses result because of the large overturning 
moment when the tank is full. In that case the axial stresses must be calculated. Axial 
stress due to overturning moment, M, is given simply by the expression: 
a = 4M/tD2 
In BS 2654 the axial stress under seismic conditions is limited to 0.20Et/R, which is 
considered a reasonable value when the cylinder is also under internal hydrostatic 
pressure. API650 uses a similar value, provided that the internal pressure exceeds a 
value which depends on the tank size. 
Although axial stresses do not need to be calculated for service conditions, the tank 
does have to be checked for uplift when it is empty and subject to wind loading. If 
necessary, anchorages must be provided; a typical example is shown in Figure 7.
4.3 Primary Wind Girders
A tank with a fixed roof is considered to be adequately restrained in its cylindrical 
shape by the roof; no additional stiffening is needed at the top of the shell, except 
possibly as part of an effective compression ring (see Section 5.2). 
At the top of an open tank (or one with a floating roof), circumferential stiffening is 
needed to maintain the roundness of the tank when it is subject to wind load. This 
stiffening is particularly necessary when the tank is empty. 
The calculation of the stability of stiffened tanks is a complex matter. Fortunately, 
investigations into the subject have led to an empirical formula, based on work by De 
Wit, which is easily applied in design. In BS 2654 this formula is expressed as a 
required minimum section modulus given by: 
Z = 0,058 D2 H 
where Z is the (elastic) section modulus (cm3) of the effective section of the ring 
girder, including a width of shell plate acting with the added stiffener 
D is the tank diameter (m) 
H is the height of the tank (m) 
The formula presumes a design wind speed of 45 m/s. For other wind speeds it may 
be modified by multiplying by the ratio of the basic wind pressure at the design speed 
to that at 45 m/s, i.e. by (V/45)2. 
Wind girders are usually formed by welding an angle or a channel around the top edge 
of the shell. Examples are shown in Figure 8. Note that continuous fillet welds should 
always be used on the upper edge of the connection, to avoid a corrosion trap.
It is recognised that application of the above formula to tanks over 60 m diameter 
leads to unnecessarily large wind girders; the code allows the size to be limited to that 
needed for a 60 m tank. 
Primary wind girders are normally external to the tank. Settlement tanks usually 
require a gutter around the inside edge of the tank, into which the water spills and 
passes to the outlet. Although this detail is not covered in the code, a suitable gutter 
detail can participate as a primary wind girder, provided it is relatively close to the top 
of the tank. In that event a kerb angle is also required at the free edge; the arrangement 
of a low ring girder and a kerb angle is covered by the design rules. 
4.4 Secondary Wind Girders 
Although the primary wind girder or the roof will stabilise the tank over its full height, 
local buckling can occur in empty tall tanks between the top of the tank and its base. 
To prevent this local buckling, secondary wind girders are introduced at intervals in 
the height of the tank. The determination of the number and position of these 
secondary wind girders is dealt with in BS 2654 (but not in API 650). 
The procedure is based on determining the length of tube for which, with the ends 
held circular, the elastic critical buckling will occur at a given uniform external 
pressure. Such buckling would also occur in a longer tube which is restrained at 
intervals equal to that length. 
The critical stress for a length of tube, l, of radius R and thickness t, is given in Roark 
[4] by the formula: 
Using values of E and  for steel, rearranging and simplifying, this reduces 
approximately to the expression in the code: 
where D is the diameter of the shell (m) 
Hp is the maximum permitted spacing of rings (m) 
(equivalent to critical length, l)
tmin is the thickness of the shell plate (mm) 
Vw is the design wind speed (m/s) 
va is the vacuum (mbar) 
However, tank shells in practice are made up of courses, and the thickness of the 
plating increases from the top to the bottom. Fortunately, this non-uniform situation 
can be converted into an equivalent uniform situation by noting that the critical length 
l (or maximum spacing Hp) is proportional to t5/2. Taking the thinnest plate (the top 
course) as reference (tmin), courses of height h and thickness t can be converted to an 
equivalent height of a tube of the thin plate which has the same effective slenderness 
by applying the correction: 
where t is the thickness of each course in turn 
He is the equivalent height of each course at a thickness of tmin 
The equivalent heights of all the courses are added to give the total equivalent height 
(length of tube) and divided by the critical length Hp to determine the minimum 
number of intervals and thus the number of intermediate rings. The positions of the 
intermediate rings, which are equally spaced on the equivalent tube, must be 
established by converting positions on the tube back to positions on the tank, by the 
reverse of the above procedure. 
The whole process is illustrated by an example in BS 2654. 
The stiffening is achieved by welding an angle to the surface of the shell plate in the 
same manner as for the primary wind girder. Minimum sizes for this angle are given 
in the code [1]. 
5. FIXED ROOF DESIGN 
5.1 General 
Fixed roofs of cylindrical tanks are formed of steel plate and are of either conical or 
domed (spherically curved) configuration. The steel plates can be entirely self 
supporting (by 'membrane' action), or they may rest on top of some form of support 
structure.
Membrane roofs are more difficult to erect - they require some temporary support 
during placing and welding - and are usually found only on smaller tanks. 
Permanent support steelwork for the roof plate may either span the complete diameter 
of the tank or may in turn be supported on columns inside the tank. The use of a single 
central column is particularly effective in relatively small tanks (15-20 m diameter), 
for example. 
The main members of the support steelwork are, naturally, radial to the tank. They can 
be simple rolled beam sections or, for larger tanks, they can be fabricated trusses. 
Roof plates are usually lapped and fillet welded to one another. For low pressure 
tanks, they do not need to be welded to any structure which supports them, but they 
must normally be welded to the top of the shell. 
5.2 Membrane Roofs 
In a membrane roof, the forces from dead and imposed loads are resisted by 
compressive radial stresses. The net upward forces from internal pressure minus dead 
load are resisted by tensile radial stresses. 
Conical roofs usually have a slope of 1:5. Spherical roofs usually have a radius of 
curvature between 0,8 and 1,5 times the diameter of the tank. 
Limitations on buckling under radial compression are expressed in BS2654 as: 
where R1 is the radius of curvature of the roof (m) 
Pe is the external loading plus self weight (kN/m2) 
E is Young's modulus (N/mm2) 
tr is the roof plate thickness (mm) 
For conical roofs, R1 is taken as the radius of the shell divided by the sine of the angle 
between the roof and the horizontal, i.e. R1 = R/sin . 
Using a value of Pe = 1,7 kN/m2, i.e. 1,2 kN/m2, superimposed load plus 0,5kN/m2 for 
dead load, (equivalent to about 6 mm plate thickness) and the E value for steel, gives:
tr = 0,36 R1 
A similar expression is given in API650, expressed in imperial units and for a loading 
of 45lb/ft2 (= 2,2 kN/m2). 
For tensile forces, stresses are limited to: 
(for spherical roofs) 
(for conical roofs) 
where  is the joint efficiency factor 
S is the allowable design stress (in N/mm2) 
p is the internal pressure (in mbar) 
Although lapped and double fillet welded joints are acceptable, they have a joint 
efficiency factor of only 0,5; butt welded joints have a factor of 1,0. 
For downward loads, the radial compression is complemented by ring tension. 
For upward loads, i.e. under internal pressure, the radial tension has to be 
complemented by a circumferential compression. This compression can only be 
provided by the junction section between roof and shell. This is expressed as a 
requirement for a minimum area of the effective section, as shown in Figure 9:
where Sc is the allowable compressive stress (in N/mm2) 
R is the radius of the tank (in m) 
 is the slope of the roof at roof-shell connection
The allowable compressive stress for this region is taken to be 120 N/mm2 in BS2654 
[1]. 
5.3 Supported Roofs 
Radial members supporting the roof plate permit the plate thickness to be kept to a 
minimum. They greatly facilitate the construction of the roof. 
Radial beams are arranged such that the span of the plate between them is kept down 
to a minimum of about 2 m. This limit allows the use of 5 mm plate for the roof. The 
plate simply lies on the beams and is not connected to them. 
Supported roofs are most commonly of conical shape, although spherical roofs can be 
used if the radial beams are curved. 
The roof support structure can either be self supporting or be supported on internal 
columns. Typical arrangements are shown in section in Figures 10 and 11. Self 
supporting roofs are essential when there is an internal floating cover.
When columns are used to support the roof, the slope may be as low as 1:16. When 
the roof is self supporting it may be more economic to use a steeper roof.
Not all radial members continue to the centre of the tank. Those that do may be 
considered as main support beams; the secondary radial members may be considered 
as rafters - they are supported at their inner ends on ring beams between the main 
support members. Where internal columns are used they will be beneath the main 
support members. Typical plan arrangements are shown in Figure 11. 
The main support members need to be restrained at intervals to stabilise them against 
lateral-torsional buckling. Cross bracing is provided in selected bays. 
In API650 it is permitted to assume that friction between the roof plate and the beam 
is adequate to restrain the compression flange of the secondary rafter beams, provided 
that they are not too deep; such restraint cannot be assumed for the main beams, 
however. 
The main support members may be subject to bending and axial load. Where they are 
designed for axial thrust, the central ring must be designed as a compression ring; the 
top of the shell must be designed for the hoop forces associated with the axial forces 
in the support members. 
Design of beams and support columns may generally follow conventional building 
code rules, though it must be noted that both BS 2654 and API650 are allowable stress 
codes. In the British code reference is therefore made to BS449 [5], rather than to a 
limit state code. 
The shell/roof junction zone must be designed for compression, in the same way as 
described above for membrane roofs. 
5.4 Venting 
Venting has to be provided to cater for movement of the contents into and out of the 
tank and for temperature change of the air in the tank. Venting can be provided by 
pressure relief valves or by open vents. 
For storage of petroleum products, emergency pressure relief has to be provided to 
cater for heating due to an external fire. Pressure relief can be achieved either by 
additional emergency venting or by designing the roof to shell joint as frangible (this 
means, principally, that the size of the fillet weld between the roof and the shell is 
limited in size - a limit of 5 mm is typical). 
6. DESIGN OF FLOATING ROOFS AND COVERS 
6.1 Use of Floating Roofs and Covers
As mentioned in Section 5.4, tanks need to be vented to cater for the expansion and 
contraction of the air. In petroleum tanks, the free space above the contents contains 
an air/vapour mixture. When the mixture expands in the heat of the day, venting 
expels some of this vapour. At night, when the temperature drops, fresh air is drawn in 
and more of the contents evaporates to saturate the air. The continued breathing can 
result in substantial evaporation losses. Measures are needed to minimise these losses; 
floating roofs and covers are commonly used for this purpose. 
6.2 Floating Roofs 
A floating roof is sometimes provided instead of a fixed roof. The shell is then 
effectively open at the top and is designed accordingly. 
During service, a floating roof is completely supported on the liquid and must 
therefore be sufficiently buoyant; buoyancy is achieved by providing liquid-tight 
compartments in one of two forms of roof - pontoon type and double deck type. 
A pontoon roof has an annular compartment, divided by bulkheads, and a central 
single skin diaphragm. The central diaphragm may need to be stiffened by radial 
beams. 
A double deck roof is effectively a complete set of compartments over the whole 
diameter of the tank; two circular skins are joined to circumferential plates and 
bulkheads to form a disk or piston. 
Both types of roof must remain buoyant even if some compartments are punctured 
(typically two compartments). The central deck of a pontoon roof should also be 
presumed to be punctured for this design condition. 
Because the roof is open to the environment, it catches rain, which must be drained 
off. Drainage is achieved by a system on the roof which connects to flexible pipework 
inside the tank and thence through the shell or bottom plates to a discharge. The 
design is required to ensure that the roof continues to float in the event of a block in 
the drainage system which results in a surcharge of water on the roof (usually 250 mm 
of water). 
When the tank is emptied, the roof cannot normally be allowed to fall to the bottom of 
the tank, because there is internal pipework; the roof is therefore fitted with legs 
which keep it clear of the bottom. At this stage the roof must be able to carry a 
superimposed load (1,2 kN/m2) plus any accumulated rainwater.
For maintenance of the drainage system and for access to nozzles through the roof for 
various purposes, maintenance personnel need access from the top of the shell to the 
roof whatever the level of contents in the tank. Access is usually achieved by a 
movable ladder or stairway, pinned to the shell and resting on the roof. For 
maintenance of the tank when it is empty, an access manhole must be provided 
through the roof. 
A typical arrangement of a pontoon type roof is shown in Figure 12. 
6.3 Floating Covers 
Where a cover to the contents is provided inside a fixed roof tank, to reduce 
evaporation or ingress of contaminants (e.g. water or sand), a much lighter cover or 
screen can be provided. 
Such a cover is likely to be manufactured from lighter materials than steel, though a 
shallow steel pan can sometimes be provided. The cover does not need to be provided
with access ladders, nor to be designed for surcharge. It does have to be designed to 
be supported at low level when the tank is empty and to carry a small live load in that 
condition. 
Detailed recommendations for the design of internal floating covers are given in 
Appendix E of BS 2654 [1]. 
7. MANHOLES, NOZZLES AND OPENINGS 
7.1 Manholes 
Access is required inside fixed roof tanks for maintenance and inspection purposes. 
Such access can be provided through the roof or through the shell wall. Manholes 
through the roof have the advantage that they are always accessible, even when the 
tank is full. Access through the shell wall is more convenient for cleaning out (some 
access holes are D-shaped and flush with the bottom for cleaning out purposes). 
A manhole through a roof should be at least 500 mm diameter. Stiffening 
arrangements around the hole in the roof plate, and the type of cover, depend on the 
design of the roof. Access to the roof manhole must be provided by ladders, with 
suitable handrails and walkways on the roof. 
A manhole through the shell wall should be at least 600 mm diameter and is normally 
positioned just above the bottom of the tank. A typical detail is shown in section in 
Figure 13. Further details of this example, and details of clean-out openings, are given 
in BS2654 [1].
Clearly, the cutting of an opening in the shell interferes with the structural action of 
the shell. The loss of section of shell plate is compensated by providing additional 
cross-section area equal to 75% of that lost. The area must be provided within a 
circular region around the hole, though the actual reinforcement should extend beyond 
that region. Reinforcement can be provided in one of three ways: 
(i) a reinforcing plate welded onto the shell plate (similar to the section in Figure 13) 
(ii) an insert of thicker plate locally (in which the manhole is cut) 
(iii) a thicker shell plate than that required for that course of the shell 
7.2 Nozzles
As well as manholes for access and cleaning out, nozzles are required through the 
shell roof and bottom for inlet, outlet, and drainage pipes, and for vents in the roof. 
They are normally made by welding a cylindrical section of plate into a circular hole 
in the structural plate. For small nozzles, no reinforcement is necessary, the extra 
material is considered sufficient. Larger holes must be reinforced in the same way as 
manholes. An example of a roof nozzle detail is shown in Figure 14. 
8. CONCLUDING SUMMARY 
 Oil and oil products are most commonly stored in cylindrical steel tanks at 
atmospheric pressure or at low pressure. Water is also sometimes stored in 
cylindrical steel tanks. 
 The two design standards applied most widely to the design of welded 
cylindrical tanks are BS2654 and API 650. 
 Tanks are usually manufactured from plain carbon steel plate. It is readily 
weldable. 
 A tank is designed for the most severe combination of the various possible 
loadings. 
 For petroleum storage tanks, steel bottom plates are specified, laid and fully 
supported on a prepared foundation. Water tanks may also have a steel bottom 
or a reinforced concrete slab may be specified.
 Vertical cylindrical tanks carry the hydrostatic pressure by simple hoop tension. 
The cylindrical shell has to carry both its own weight and the weight of the 
supported roof by axial stresses. Wind loading on the tank influences the axial 
stress. 
 For open tanks, primary wind girders are required to maintain the roundness of 
the tank when it is subject to wind load. Secondary wind girders are needed in 
tall tanks. 
 Roofs may be fixed or floating. A cover to the contents of a fixed roof tank 
may be provided to reduce evaporation or ingress of contaminants. 
 Manholes are provided for access and nozzles allow inlet, outlet and drainage, 
and venting of the space under the roof. 
9. REFERENCES 
[1] BS 2654: 1984, Specification for manufacture of vertical steel welded storage 
tanks with butt-welded shells for the petroleum industry, British Standards Institution, 
London. 
[2] API 650, Welded Steel Tanks for Oil Storage, 8th Edition, November 1988, API. 
[3] BS EN 10025, 1990, Hot Rolled Products of Non-alloy Structural Steels and their 
Technical Delivery Conditions, British Standards Institution, London. 
[4] Young, W. C., Roark's Formulas for Stress and Strain, McGraw Hill, 1989. 
[5] BS 449: Part 2: 1969, Specification for the Use of Structural Steel in Building, 
British Standards Institution, London. 
Appendix A Differences between BS 2654 and API 650 
The following are the principal differences between the British Standard, BS 2654 [1] 
and the American Petroleum Institute Standard, API650 [2]: 
(a) API 650 specifies different allowable stresses for service and water testing. BS 
2654 specifies an allowable stress for water testing only, which will allow oils with 
any specific gravity up to 1 to be stored in the tank. 
(b) The allowable design stresses of BS 2654 are based on guaranteed minimum yield 
strength whereas the design stresses of API 650 are based on the guaranteed minimum 
ultimate tensile strength.
(c) BS 2654 specifies more stringent requirements for the weldability of the shell 
plates. 
(d) The notch ductility requirements of BS 2654 are based on the results of a great 
number of wide plate tests. This system considers a steel acceptable if, for the 
required thickness, the test plate does not fail at test temperature before it has yielded 
at least 0,5%. This system gives the same safety factor for all thicknesses. 
In API 650 a fixed value and test temperature is given for the impact tests for all 
thicknesses. As the tendency to brittle fracture increases with increasing plate 
thickness it means that API 650 in fact allows a lower safety factor for large tanks 
than for smaller ones. 
(e) The steels specified by API 650 guarantee their notch ductility by chemical 
analysis but without guaranteed impact values. BS 2654 requires guaranteed impact 
values where necessary. 
(f) BS 2654 gives a clearer picture of how to determine the size and location of 
secondary wind girders. 
Previous | Next | Contents

Contenu connexe

Tendances

Lec11 Continuous Beams and One Way Slabs(1) (Reinforced Concrete Design I & P...
Lec11 Continuous Beams and One Way Slabs(1) (Reinforced Concrete Design I & P...Lec11 Continuous Beams and One Way Slabs(1) (Reinforced Concrete Design I & P...
Lec11 Continuous Beams and One Way Slabs(1) (Reinforced Concrete Design I & P...Hossam Shafiq II
 
Horizontal Vessel Loading Calculation
 Horizontal Vessel Loading Calculation Horizontal Vessel Loading Calculation
Horizontal Vessel Loading CalculationFadhel AlMohammad
 
Lec07 Analysis and Design of Doubly Reinforced Beam (Reinforced Concrete Desi...
Lec07 Analysis and Design of Doubly Reinforced Beam (Reinforced Concrete Desi...Lec07 Analysis and Design of Doubly Reinforced Beam (Reinforced Concrete Desi...
Lec07 Analysis and Design of Doubly Reinforced Beam (Reinforced Concrete Desi...Hossam Shafiq II
 
Steel stacks guide
Steel stacks guideSteel stacks guide
Steel stacks guideKhaled Eid
 
Design Procedure of Singly,Doubly & T-Beam(As Per ACI code)
Design Procedure of Singly,Doubly & T-Beam(As Per ACI code)Design Procedure of Singly,Doubly & T-Beam(As Per ACI code)
Design Procedure of Singly,Doubly & T-Beam(As Per ACI code)Jahidur Rahman
 
Design for Short Axially Loaded Columns ACI318
Design for Short  Axially  Loaded Columns ACI318Design for Short  Axially  Loaded Columns ACI318
Design for Short Axially Loaded Columns ACI318Abdullah Khair
 
Aci reinforcement limits
Aci reinforcement limitsAci reinforcement limits
Aci reinforcement limitsMeesum Zaidi
 
manual stress analysis
manual stress analysismanual stress analysis
manual stress analysisBHARAT BELLAD
 
Use of bitumen in tank foundation and as a joint filling material
Use of bitumen in tank foundation and as a joint filling materialUse of bitumen in tank foundation and as a joint filling material
Use of bitumen in tank foundation and as a joint filling materialAshish kumar Yadav
 
Analysis and Design of Plate Girder Bridges_.docx
Analysis and Design of Plate Girder Bridges_.docxAnalysis and Design of Plate Girder Bridges_.docx
Analysis and Design of Plate Girder Bridges_.docxAdnan Lazem
 
Stress analysis of storage tank piping - Jeba Anand
Stress analysis of storage tank  piping - Jeba AnandStress analysis of storage tank  piping - Jeba Anand
Stress analysis of storage tank piping - Jeba AnandJeba Anand Nadar
 
Lec10 Bond and Development Length (Reinforced Concrete Design I & Prof. Abdel...
Lec10 Bond and Development Length (Reinforced Concrete Design I & Prof. Abdel...Lec10 Bond and Development Length (Reinforced Concrete Design I & Prof. Abdel...
Lec10 Bond and Development Length (Reinforced Concrete Design I & Prof. Abdel...Hossam Shafiq II
 
Column base plates_prof_thomas_murray
Column base plates_prof_thomas_murrayColumn base plates_prof_thomas_murray
Column base plates_prof_thomas_murrayAlberto Rosado
 
Chapter 7 DESIGN OF FOOTING
Chapter 7 DESIGN OF FOOTINGChapter 7 DESIGN OF FOOTING
Chapter 7 DESIGN OF FOOTINGKavitaSingh219
 

Tendances (20)

Base ring analysis
Base ring analysisBase ring analysis
Base ring analysis
 
Lec11 Continuous Beams and One Way Slabs(1) (Reinforced Concrete Design I & P...
Lec11 Continuous Beams and One Way Slabs(1) (Reinforced Concrete Design I & P...Lec11 Continuous Beams and One Way Slabs(1) (Reinforced Concrete Design I & P...
Lec11 Continuous Beams and One Way Slabs(1) (Reinforced Concrete Design I & P...
 
Horizontal Vessel Loading Calculation
 Horizontal Vessel Loading Calculation Horizontal Vessel Loading Calculation
Horizontal Vessel Loading Calculation
 
Lec07 Analysis and Design of Doubly Reinforced Beam (Reinforced Concrete Desi...
Lec07 Analysis and Design of Doubly Reinforced Beam (Reinforced Concrete Desi...Lec07 Analysis and Design of Doubly Reinforced Beam (Reinforced Concrete Desi...
Lec07 Analysis and Design of Doubly Reinforced Beam (Reinforced Concrete Desi...
 
Building project rc column
Building project rc columnBuilding project rc column
Building project rc column
 
Steel stacks guide
Steel stacks guideSteel stacks guide
Steel stacks guide
 
Design Procedure of Singly,Doubly & T-Beam(As Per ACI code)
Design Procedure of Singly,Doubly & T-Beam(As Per ACI code)Design Procedure of Singly,Doubly & T-Beam(As Per ACI code)
Design Procedure of Singly,Doubly & T-Beam(As Per ACI code)
 
Beam design
Beam designBeam design
Beam design
 
Design for Short Axially Loaded Columns ACI318
Design for Short  Axially  Loaded Columns ACI318Design for Short  Axially  Loaded Columns ACI318
Design for Short Axially Loaded Columns ACI318
 
WIND LOADING ON LIGHTING STEEL COLUMN - EN 40-3-1:2013
WIND LOADING ON LIGHTING STEEL COLUMN - EN 40-3-1:2013WIND LOADING ON LIGHTING STEEL COLUMN - EN 40-3-1:2013
WIND LOADING ON LIGHTING STEEL COLUMN - EN 40-3-1:2013
 
Aci reinforcement limits
Aci reinforcement limitsAci reinforcement limits
Aci reinforcement limits
 
manual stress analysis
manual stress analysismanual stress analysis
manual stress analysis
 
Use of bitumen in tank foundation and as a joint filling material
Use of bitumen in tank foundation and as a joint filling materialUse of bitumen in tank foundation and as a joint filling material
Use of bitumen in tank foundation and as a joint filling material
 
Axially Loaded Column
Axially Loaded ColumnAxially Loaded Column
Axially Loaded Column
 
Analysis and Design of Plate Girder Bridges_.docx
Analysis and Design of Plate Girder Bridges_.docxAnalysis and Design of Plate Girder Bridges_.docx
Analysis and Design of Plate Girder Bridges_.docx
 
Stress analysis of storage tank piping - Jeba Anand
Stress analysis of storage tank  piping - Jeba AnandStress analysis of storage tank  piping - Jeba Anand
Stress analysis of storage tank piping - Jeba Anand
 
Lec10 Bond and Development Length (Reinforced Concrete Design I & Prof. Abdel...
Lec10 Bond and Development Length (Reinforced Concrete Design I & Prof. Abdel...Lec10 Bond and Development Length (Reinforced Concrete Design I & Prof. Abdel...
Lec10 Bond and Development Length (Reinforced Concrete Design I & Prof. Abdel...
 
Column base plates_prof_thomas_murray
Column base plates_prof_thomas_murrayColumn base plates_prof_thomas_murray
Column base plates_prof_thomas_murray
 
Chapter 7 DESIGN OF FOOTING
Chapter 7 DESIGN OF FOOTINGChapter 7 DESIGN OF FOOTING
Chapter 7 DESIGN OF FOOTING
 
Secant pile wall for emergency dump pond
Secant pile wall for emergency dump pondSecant pile wall for emergency dump pond
Secant pile wall for emergency dump pond
 

Similaire à HV tower design 1

Similaire à HV tower design 1 (20)

143137557 storage-tanks
143137557 storage-tanks143137557 storage-tanks
143137557 storage-tanks
 
Paper
PaperPaper
Paper
 
6- storage tank except design.pdf
6- storage tank except design.pdf6- storage tank except design.pdf
6- storage tank except design.pdf
 
500630977-CH-1-Pressure-Vessel-Design-1.pdf
500630977-CH-1-Pressure-Vessel-Design-1.pdf500630977-CH-1-Pressure-Vessel-Design-1.pdf
500630977-CH-1-Pressure-Vessel-Design-1.pdf
 
Seismic Response and design of Tanks.pptx
Seismic Response and design of Tanks.pptxSeismic Response and design of Tanks.pptx
Seismic Response and design of Tanks.pptx
 
Tank design - word
Tank design - wordTank design - word
Tank design - word
 
pv_rules.pdf
pv_rules.pdfpv_rules.pdf
pv_rules.pdf
 
pv_rules.pdf
pv_rules.pdfpv_rules.pdf
pv_rules.pdf
 
haug.pdf
haug.pdfhaug.pdf
haug.pdf
 
Aboveground_storage_tank_design_and_operation.pdf
Aboveground_storage_tank_design_and_operation.pdfAboveground_storage_tank_design_and_operation.pdf
Aboveground_storage_tank_design_and_operation.pdf
 
Dk25664666
Dk25664666Dk25664666
Dk25664666
 
Multi
MultiMulti
Multi
 
Dewar vessal new
Dewar vessal newDewar vessal new
Dewar vessal new
 
Question bank
Question bankQuestion bank
Question bank
 
office final ppt [7760835] final update
office final ppt [7760835] final updateoffice final ppt [7760835] final update
office final ppt [7760835] final update
 
Engine quiz
Engine quizEngine quiz
Engine quiz
 
Storage Tank.pdf
Storage Tank.pdfStorage Tank.pdf
Storage Tank.pdf
 
Design Of Pressure Vessel
Design Of  Pressure VesselDesign Of  Pressure Vessel
Design Of Pressure Vessel
 
Parametric study of rcc staging (support structure) for overhead water tanks ...
Parametric study of rcc staging (support structure) for overhead water tanks ...Parametric study of rcc staging (support structure) for overhead water tanks ...
Parametric study of rcc staging (support structure) for overhead water tanks ...
 
CAPSTONE PROJECT PPT.pptx
CAPSTONE PROJECT PPT.pptxCAPSTONE PROJECT PPT.pptx
CAPSTONE PROJECT PPT.pptx
 

Dernier

data_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfdata_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfJiananWang21
 
Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01KreezheaRecto
 
Double Revolving field theory-how the rotor develops torque
Double Revolving field theory-how the rotor develops torqueDouble Revolving field theory-how the rotor develops torque
Double Revolving field theory-how the rotor develops torqueBhangaleSonal
 
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlyKubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlysanyuktamishra911
 
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...Call Girls in Nagpur High Profile
 
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfKamal Acharya
 
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptxBSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptxfenichawla
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Bookingdharasingh5698
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performancesivaprakash250
 
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...ranjana rawat
 
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...SUHANI PANDEY
 
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...tanu pandey
 
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night StandCall Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Standamitlee9823
 
chapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineeringchapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineeringmulugeta48
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Call Girls in Nagpur High Profile
 
Unit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfUnit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfRagavanV2
 
AKTU Computer Networks notes --- Unit 3.pdf
AKTU Computer Networks notes ---  Unit 3.pdfAKTU Computer Networks notes ---  Unit 3.pdf
AKTU Computer Networks notes --- Unit 3.pdfankushspencer015
 

Dernier (20)

data_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfdata_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdf
 
Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01
 
Double Revolving field theory-how the rotor develops torque
Double Revolving field theory-how the rotor develops torqueDouble Revolving field theory-how the rotor develops torque
Double Revolving field theory-how the rotor develops torque
 
Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024
 
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort ServiceCall Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
 
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlyKubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghly
 
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
 
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
 
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptxBSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performance
 
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
 
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
 
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
 
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night StandCall Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
 
chapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineeringchapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineering
 
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
Unit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfUnit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdf
 
AKTU Computer Networks notes --- Unit 3.pdf
AKTU Computer Networks notes ---  Unit 3.pdfAKTU Computer Networks notes ---  Unit 3.pdf
AKTU Computer Networks notes --- Unit 3.pdf
 

HV tower design 1

  • 1. Previous | Next | Contents ESDEP WG 15 STRUCTURAL SYSTEMS: MISCELLANEOUS Lecture 15C.1: Design of Tanks for the Storage of Oil and Water OBJECTIVE/SCOPE: The lecture describes the basic principles used in the design of tanks for the storage of oil or water. It covers the design of vertical cylindrical tanks, and reference is made to the British Standard BS 2654 [1] and to the American Petroleum Industry Standard API650 [2]. PREREQUISITES None. RELATED LECTURES Lecture 8.6: Introduction to Shell Structures Lecture 8.8: Design of Unstiffened Cylinders SUMMARY Welded cylindrical tanks are commonly used to store oil products or water. The principal structural element of these tanks is a vertical steel cylinder, or shell, which is made by welding together a series of rectangular plates and which restrains the hydrostatic pressures by hoop tension forces. The tank is normally provided with a flat steel plated bottom which sits on a prepared foundation, and with a fixed roof attached to the top of the shell wall. This lecture explains the design basis for the structural elements of cylindrical tanks and illustrates the arrangements and the key details involved. 1. DESIGN OF WELDED CYLINDRICAL TANKS
  • 2. 1.1 General Oil and oil products are most commonly stored in cylindrical steel tanks at atmospheric pressure or at low pressure. The tanks are flat bottomed and are provided with a roof which is of conical or domed shape. Water is also sometimes stored in cylindrical steel tanks. When used to store potable water they are of a size suitable to act as a service reservoir for a local community; they have a roof to prevent contamination of the water. Cylindrical tanks are also used in sewage treatment works for settlement and holding tanks; they are usually without a roof. The sizes of cylindrical tanks range from a modest 3m diameter up to about 100m diameter, and up to 25m in height. They consist of three principal structural elements - bottom, shell and roof. For petroleum storage, the bottom is formed of steel sheets, laid on a prepared base. Some tanks for water storage use a reinforced concrete slab as the base of the tank, instead of steel sheets. The shell, or cylindrical wall, is made up of steel sheets and is largely unstiffened. The roof of the tank is usually fixed to the top of the shell, though floating roofs are provided in some circumstances. A fixed roof may be self supporting or partially supported through membrane action, though generally the roof plate is supported on radial beams or trusses. 1.2 Design Standards Clearly, common standards are generally applicable whether a tank holds oil or water, though it is the petroleum industry which has been responsible for the development of many of the design procedures and standards. The two standards applied most widely are British Standard BS 2654 [1] and the American Petroleum Institute Standard API 650 [2]. These two Standards have much in common, although there are some significant differences (see Appendix A). Other standards, American and European, are not applied much outside their respective countries. This lecture will generally follow the requirements of BS 2654 [1]. This standard is both a design code and a construction specification. The design code is based on allowable stress principles, not on a limit state basis.
  • 3. 1.3 Design Pressure and Temperature Tanks designed for storage at nominally atmospheric pressure must be suitable for modest internal vacuum (negative pressure). Tanks may also be designed to work at relatively small positive internal pressures (up to 56 mbar (5,6 kN/m2), according to BS2654. Non-refrigerated tanks are designed for a minimum metal temperature which is based on the lowest ambient air temperature (typically, ambient plus 10oC) or the lowest temperature of the contents, whichever is the lower. No maximum service temperature is normally specified. 1.4 Material Tanks are usually manufactured from plain carbon steel plate (traditionally referred to as mild steel) of grades S235 or S275 (to EN 10 025 [3]), or equivalent. Such material is readily weldable. The use of higher strength grades of low alloy steel (e.g. Grade S355) is less common, though its use is developing. Notch ductility at the lowest service temperature is obtained for thicker materials (> 13 mm) by specifying minimum requirements for impact tests. This is normally achieved by specifying an appropriate sub-grade to EN 10 025 [3]. Internally, oil tanks are normally unpainted. Water tanks may be given a coating (provided it is suitably inert, where the water is potable), or may be given cathodic protection. Externally, tanks are normally protected. Where any steel is used uncoated, an allowance must be made in the design for loss of thickness due to corrosion. 2. DESIGN LOADING A tank is designed for the most severe combination of the various possible loadings. 2.1 Dead Load The dead load is that due to the weight of all the parts of the tank. 2.2 Superimposed Load A minimum superimposed load of 1,2 kN/m2 (over the horizontal projected area) is applied to the roof of the tank. This load is commonly known as the 'snow load', but in fact represents, as well as a nominal snow load, any other imposed loads, such as
  • 4. maintenance equipment, which might be applied to the roof, and it includes the internal vacuum load. It is therefore applicable even in locations where snow is not experienced. Non-pressure tanks are often fitted with valves which do not open until the vacuum reaches a value of 2,5 mbar, to contain vapour losses. By the time a valve is fully open, a vacuum of 5 mbar (0,5 kN/m2) may have developed. Even without valves a tank should be designed for a vacuum of 5 mbar, to cater for differential pressure under wind loads. In pressure tanks the valves may be set to 6 mbar vacuum, in which case a pressure difference of 8,5 mbar (0,85 kN/m2) may develop. Actual predicted snow load or other superimposed load, plus appropriate vacuum pressure, should be used when it is greater than the specified minimum. 2.3 Contents The weight and hydrostatic pressure of the contents, up to the full capacity of the tank, should be applied. Full capacity is usually determined by an overflow near the top of the tank; for a tank without any overflow, the contents should be taken to fill the tank to the top of the shell. For oil and oil products, the relative density of the contents is less than 1.0, but tanks for such liquids are normally tested by filling with water. A density of 1000 kg/m3 should therefore be taken as a minimum. 2.4 Wind Loads Wind loads are determined on the basis of a design wind speed. Maximum wind speed depends on the area in which the tank is to be built; typically a value of 45 m/s is taken as the design wind speed, representing the maximum 3-second gust speed which is exceeded, on average, only once every 50 years. 2.5 Seismic Loads In some areas, a tank must be designed to withstand seismic loads. Whilst some guidance is given in BS 2654 [1] and API650 [2] on the design of the tank, specialised knowledge should be applied in determining seismic loads. 3. BOTTOM DESIGN For petroleum storage tanks, steel bottom plates are specified, laid and fully supported on a prepared foundation.
  • 5. The steel plates are directly supported on a bitumen-sand layer on top of a foundation, usually of compacted fill or, if the subsoil is weak, possibly a reinforced concrete raft. A typical foundation pad is shown in Figure 1 and a detailed description of the formation of this example is given in Appendix A of BS 2654 [1]. The bottom is made up of a number of rectangular plates, surrounded by a set of shaped plates, called sketch plates, to give a circular shape, as shown in Figure 2. The plates slightly overlap each other and are pressed locally at the corners where three plates meet (see Figure 3). Lapped and fillet welded joints are preferred to butt welded joints (which must be welded onto a backing strip below the joint) because they are easier and cheaper to make.
  • 6.
  • 7. For larger tanks (over 12,5 m diameter, according to BS 2654) a ring of annular plates is provided around the group of rectangular plates. The radial joints between the annular plates are butt welded, rather than lapped, because of the ring stiffening which the plates provide to the bottom of the shell. A typical arrangement is shown in Figure 4.
  • 8. The shell sits on the sketch or annular plates, just inside the perimeter and is fillet welded to them (see Figure 5).
  • 9.
  • 10. The bottom plates act principally as a seal to the tank. The only load they carry, apart from local stiffening to the bottom of the shell, is the pressure from the contents, which is then transmitted directly to the base. Stress calculations are not normally required for the base, though BS 2654 sets out minimum thicknesses of plate depending on the size of the tank. Water tanks may also have a steel bottom. In some circumstances a reinforced concrete slab is specified instead. There are no standard details for the connection between a shell and a concrete slab, though a simple arrangement of an angle welded to the bottom edge of the shell and bolted to the slab will usually suffice. 4. SHELL DESIGN 4.1 Circumferential Stresses Vertical cylinder tanks carry the hydrostatic pressures by simple hoop tension. No circumferential stiffening is needed for this action. The circumferential tension in the shell will vary directly, in a vertical direction, according to the head of fluid at any given level. For a uniform shell thickness, the calculation of stresses is therefore straightforward. At a water depth H, the stress is given by: where D is the diameter of the tank t is the thickness of the plate  is the density of the fluid g is the gravity constant For practical reasons, it is necessary to build up the shell from a number of fairly small rectangular pieces of plate, butt welded together. Each piece will be cylindrically curved and it is convenient to build up the shell in a number of rings, or courses, one on top of the other. This technique provides, at least for deeper tanks, a convenient opportunity to use thicker plates in the lower rings and thinner plates in the upper rings. The lowest course of plates is fully welded to the bottom plate of the tank providing radial restraint to the bottom edge of the plate. Similarly, the bottom edge of any
  • 11. course which sits on top of a thicker course is somewhat restrained because the thicker plate is stiffer. The effect of this on the hoop stresses is illustrated in Figure 6. Consequently, because of these restraints, an empirical adjustment is introduced into the design rules which effectively requires that any course is simply designed for the pressure 300mm above the bottom edge of the course, rather than the greater pressure at the bottom edge. (This is known as the 'one foot rule' in API 650 [2].) When the load due to internal pressure is taken into account and an allowance for corrosion loss is introduced, the resulting design equation is of the form in BS 2654: where t is the calculated minimum thickness (mm) w is the maximum density of the fluid (kg/l)
  • 12. H is the height of fluid above the bottom of the course being designed (m) S is the allowable design stress (N/mm2) p is the design pressure (pressure tanks only) (mbar) c is the corrosion allowance (mm) The allowable design stress in tension in the shell is generally taken to be a suitable fraction of the material yield stress. BS 2654 defines it as two-thirds of the yield stress, thus giving an overall factor of 1,5 on the plastic strength of the plate. API650 also uses two-thirds of the yield stress, but additionally limits the design stress to a smaller fraction of the ultimate strength; for higher strength steels, this is slightly more restrictive. Further, API650 allows a slightly higher stress during the hydrostatic test than the allowable design stress for service conditions when the relative density is less than 1,0. Each course is made of a number of plates, butt welded along the vertical join between the plates. Each course is butt welded to the course below along a circumferential line. Good weld procedures can minimise the distortions or deviations from the ideal flat or curved line of the surface across the weld, but some imperfection is inevitable, especially with thin material. Consequently the rules call for the vertical seams to be staggered from one course to the next - at least one third of the length of the individual plates, if possible. Holes in the shell for inlet/outlet nozzles or access manholes cause a local increase in circumferential stresses. This increase is catered for by requiring the provision of reinforcing plates. These plates may take the form of a circular doubling plate welded around the hole or of an inset piece of thicker plate. The nozzle provides some stiffening to the edge of the hole; it may also be made of sufficient size that shell reinforcement can be omitted. 4.2 Axial Stresses in the Shell The cylindrical shell has to carry its weight, and the weight of the roof which it supports, as an axial stress. In addition, wind loading on the tank contributes tensile axial stress on one side of the tank and compressive stress on the other. A thin-walled cylinder under a sufficient axial load will of course buckle locally, or wrinkle. The critical value of this stress, for a perfect cylinder, can be obtained from classical theory and, for steel, has the value:
  • 13. In practice, imperfect shells buckle at a much lower stress; an allowable stress level of as little as a tenth of the above might be more appropriate. However, in normal service the axial stresses in shells suitable to carry the circumferential loads for the size of tank used for oil and water storage are much smaller than even this level of stress. The calculation of axial stress is therefore not even called for in codes, such as BS 2654 and API650, for the service conditions. But under seismic conditions, larger stresses result because of the large overturning moment when the tank is full. In that case the axial stresses must be calculated. Axial stress due to overturning moment, M, is given simply by the expression: a = 4M/tD2 In BS 2654 the axial stress under seismic conditions is limited to 0.20Et/R, which is considered a reasonable value when the cylinder is also under internal hydrostatic pressure. API650 uses a similar value, provided that the internal pressure exceeds a value which depends on the tank size. Although axial stresses do not need to be calculated for service conditions, the tank does have to be checked for uplift when it is empty and subject to wind loading. If necessary, anchorages must be provided; a typical example is shown in Figure 7.
  • 14. 4.3 Primary Wind Girders
  • 15. A tank with a fixed roof is considered to be adequately restrained in its cylindrical shape by the roof; no additional stiffening is needed at the top of the shell, except possibly as part of an effective compression ring (see Section 5.2). At the top of an open tank (or one with a floating roof), circumferential stiffening is needed to maintain the roundness of the tank when it is subject to wind load. This stiffening is particularly necessary when the tank is empty. The calculation of the stability of stiffened tanks is a complex matter. Fortunately, investigations into the subject have led to an empirical formula, based on work by De Wit, which is easily applied in design. In BS 2654 this formula is expressed as a required minimum section modulus given by: Z = 0,058 D2 H where Z is the (elastic) section modulus (cm3) of the effective section of the ring girder, including a width of shell plate acting with the added stiffener D is the tank diameter (m) H is the height of the tank (m) The formula presumes a design wind speed of 45 m/s. For other wind speeds it may be modified by multiplying by the ratio of the basic wind pressure at the design speed to that at 45 m/s, i.e. by (V/45)2. Wind girders are usually formed by welding an angle or a channel around the top edge of the shell. Examples are shown in Figure 8. Note that continuous fillet welds should always be used on the upper edge of the connection, to avoid a corrosion trap.
  • 16.
  • 17. It is recognised that application of the above formula to tanks over 60 m diameter leads to unnecessarily large wind girders; the code allows the size to be limited to that needed for a 60 m tank. Primary wind girders are normally external to the tank. Settlement tanks usually require a gutter around the inside edge of the tank, into which the water spills and passes to the outlet. Although this detail is not covered in the code, a suitable gutter detail can participate as a primary wind girder, provided it is relatively close to the top of the tank. In that event a kerb angle is also required at the free edge; the arrangement of a low ring girder and a kerb angle is covered by the design rules. 4.4 Secondary Wind Girders Although the primary wind girder or the roof will stabilise the tank over its full height, local buckling can occur in empty tall tanks between the top of the tank and its base. To prevent this local buckling, secondary wind girders are introduced at intervals in the height of the tank. The determination of the number and position of these secondary wind girders is dealt with in BS 2654 (but not in API 650). The procedure is based on determining the length of tube for which, with the ends held circular, the elastic critical buckling will occur at a given uniform external pressure. Such buckling would also occur in a longer tube which is restrained at intervals equal to that length. The critical stress for a length of tube, l, of radius R and thickness t, is given in Roark [4] by the formula: Using values of E and  for steel, rearranging and simplifying, this reduces approximately to the expression in the code: where D is the diameter of the shell (m) Hp is the maximum permitted spacing of rings (m) (equivalent to critical length, l)
  • 18. tmin is the thickness of the shell plate (mm) Vw is the design wind speed (m/s) va is the vacuum (mbar) However, tank shells in practice are made up of courses, and the thickness of the plating increases from the top to the bottom. Fortunately, this non-uniform situation can be converted into an equivalent uniform situation by noting that the critical length l (or maximum spacing Hp) is proportional to t5/2. Taking the thinnest plate (the top course) as reference (tmin), courses of height h and thickness t can be converted to an equivalent height of a tube of the thin plate which has the same effective slenderness by applying the correction: where t is the thickness of each course in turn He is the equivalent height of each course at a thickness of tmin The equivalent heights of all the courses are added to give the total equivalent height (length of tube) and divided by the critical length Hp to determine the minimum number of intervals and thus the number of intermediate rings. The positions of the intermediate rings, which are equally spaced on the equivalent tube, must be established by converting positions on the tube back to positions on the tank, by the reverse of the above procedure. The whole process is illustrated by an example in BS 2654. The stiffening is achieved by welding an angle to the surface of the shell plate in the same manner as for the primary wind girder. Minimum sizes for this angle are given in the code [1]. 5. FIXED ROOF DESIGN 5.1 General Fixed roofs of cylindrical tanks are formed of steel plate and are of either conical or domed (spherically curved) configuration. The steel plates can be entirely self supporting (by 'membrane' action), or they may rest on top of some form of support structure.
  • 19. Membrane roofs are more difficult to erect - they require some temporary support during placing and welding - and are usually found only on smaller tanks. Permanent support steelwork for the roof plate may either span the complete diameter of the tank or may in turn be supported on columns inside the tank. The use of a single central column is particularly effective in relatively small tanks (15-20 m diameter), for example. The main members of the support steelwork are, naturally, radial to the tank. They can be simple rolled beam sections or, for larger tanks, they can be fabricated trusses. Roof plates are usually lapped and fillet welded to one another. For low pressure tanks, they do not need to be welded to any structure which supports them, but they must normally be welded to the top of the shell. 5.2 Membrane Roofs In a membrane roof, the forces from dead and imposed loads are resisted by compressive radial stresses. The net upward forces from internal pressure minus dead load are resisted by tensile radial stresses. Conical roofs usually have a slope of 1:5. Spherical roofs usually have a radius of curvature between 0,8 and 1,5 times the diameter of the tank. Limitations on buckling under radial compression are expressed in BS2654 as: where R1 is the radius of curvature of the roof (m) Pe is the external loading plus self weight (kN/m2) E is Young's modulus (N/mm2) tr is the roof plate thickness (mm) For conical roofs, R1 is taken as the radius of the shell divided by the sine of the angle between the roof and the horizontal, i.e. R1 = R/sin . Using a value of Pe = 1,7 kN/m2, i.e. 1,2 kN/m2, superimposed load plus 0,5kN/m2 for dead load, (equivalent to about 6 mm plate thickness) and the E value for steel, gives:
  • 20. tr = 0,36 R1 A similar expression is given in API650, expressed in imperial units and for a loading of 45lb/ft2 (= 2,2 kN/m2). For tensile forces, stresses are limited to: (for spherical roofs) (for conical roofs) where  is the joint efficiency factor S is the allowable design stress (in N/mm2) p is the internal pressure (in mbar) Although lapped and double fillet welded joints are acceptable, they have a joint efficiency factor of only 0,5; butt welded joints have a factor of 1,0. For downward loads, the radial compression is complemented by ring tension. For upward loads, i.e. under internal pressure, the radial tension has to be complemented by a circumferential compression. This compression can only be provided by the junction section between roof and shell. This is expressed as a requirement for a minimum area of the effective section, as shown in Figure 9:
  • 21. where Sc is the allowable compressive stress (in N/mm2) R is the radius of the tank (in m)  is the slope of the roof at roof-shell connection
  • 22. The allowable compressive stress for this region is taken to be 120 N/mm2 in BS2654 [1]. 5.3 Supported Roofs Radial members supporting the roof plate permit the plate thickness to be kept to a minimum. They greatly facilitate the construction of the roof. Radial beams are arranged such that the span of the plate between them is kept down to a minimum of about 2 m. This limit allows the use of 5 mm plate for the roof. The plate simply lies on the beams and is not connected to them. Supported roofs are most commonly of conical shape, although spherical roofs can be used if the radial beams are curved. The roof support structure can either be self supporting or be supported on internal columns. Typical arrangements are shown in section in Figures 10 and 11. Self supporting roofs are essential when there is an internal floating cover.
  • 23.
  • 24. When columns are used to support the roof, the slope may be as low as 1:16. When the roof is self supporting it may be more economic to use a steeper roof.
  • 25. Not all radial members continue to the centre of the tank. Those that do may be considered as main support beams; the secondary radial members may be considered as rafters - they are supported at their inner ends on ring beams between the main support members. Where internal columns are used they will be beneath the main support members. Typical plan arrangements are shown in Figure 11. The main support members need to be restrained at intervals to stabilise them against lateral-torsional buckling. Cross bracing is provided in selected bays. In API650 it is permitted to assume that friction between the roof plate and the beam is adequate to restrain the compression flange of the secondary rafter beams, provided that they are not too deep; such restraint cannot be assumed for the main beams, however. The main support members may be subject to bending and axial load. Where they are designed for axial thrust, the central ring must be designed as a compression ring; the top of the shell must be designed for the hoop forces associated with the axial forces in the support members. Design of beams and support columns may generally follow conventional building code rules, though it must be noted that both BS 2654 and API650 are allowable stress codes. In the British code reference is therefore made to BS449 [5], rather than to a limit state code. The shell/roof junction zone must be designed for compression, in the same way as described above for membrane roofs. 5.4 Venting Venting has to be provided to cater for movement of the contents into and out of the tank and for temperature change of the air in the tank. Venting can be provided by pressure relief valves or by open vents. For storage of petroleum products, emergency pressure relief has to be provided to cater for heating due to an external fire. Pressure relief can be achieved either by additional emergency venting or by designing the roof to shell joint as frangible (this means, principally, that the size of the fillet weld between the roof and the shell is limited in size - a limit of 5 mm is typical). 6. DESIGN OF FLOATING ROOFS AND COVERS 6.1 Use of Floating Roofs and Covers
  • 26. As mentioned in Section 5.4, tanks need to be vented to cater for the expansion and contraction of the air. In petroleum tanks, the free space above the contents contains an air/vapour mixture. When the mixture expands in the heat of the day, venting expels some of this vapour. At night, when the temperature drops, fresh air is drawn in and more of the contents evaporates to saturate the air. The continued breathing can result in substantial evaporation losses. Measures are needed to minimise these losses; floating roofs and covers are commonly used for this purpose. 6.2 Floating Roofs A floating roof is sometimes provided instead of a fixed roof. The shell is then effectively open at the top and is designed accordingly. During service, a floating roof is completely supported on the liquid and must therefore be sufficiently buoyant; buoyancy is achieved by providing liquid-tight compartments in one of two forms of roof - pontoon type and double deck type. A pontoon roof has an annular compartment, divided by bulkheads, and a central single skin diaphragm. The central diaphragm may need to be stiffened by radial beams. A double deck roof is effectively a complete set of compartments over the whole diameter of the tank; two circular skins are joined to circumferential plates and bulkheads to form a disk or piston. Both types of roof must remain buoyant even if some compartments are punctured (typically two compartments). The central deck of a pontoon roof should also be presumed to be punctured for this design condition. Because the roof is open to the environment, it catches rain, which must be drained off. Drainage is achieved by a system on the roof which connects to flexible pipework inside the tank and thence through the shell or bottom plates to a discharge. The design is required to ensure that the roof continues to float in the event of a block in the drainage system which results in a surcharge of water on the roof (usually 250 mm of water). When the tank is emptied, the roof cannot normally be allowed to fall to the bottom of the tank, because there is internal pipework; the roof is therefore fitted with legs which keep it clear of the bottom. At this stage the roof must be able to carry a superimposed load (1,2 kN/m2) plus any accumulated rainwater.
  • 27. For maintenance of the drainage system and for access to nozzles through the roof for various purposes, maintenance personnel need access from the top of the shell to the roof whatever the level of contents in the tank. Access is usually achieved by a movable ladder or stairway, pinned to the shell and resting on the roof. For maintenance of the tank when it is empty, an access manhole must be provided through the roof. A typical arrangement of a pontoon type roof is shown in Figure 12. 6.3 Floating Covers Where a cover to the contents is provided inside a fixed roof tank, to reduce evaporation or ingress of contaminants (e.g. water or sand), a much lighter cover or screen can be provided. Such a cover is likely to be manufactured from lighter materials than steel, though a shallow steel pan can sometimes be provided. The cover does not need to be provided
  • 28. with access ladders, nor to be designed for surcharge. It does have to be designed to be supported at low level when the tank is empty and to carry a small live load in that condition. Detailed recommendations for the design of internal floating covers are given in Appendix E of BS 2654 [1]. 7. MANHOLES, NOZZLES AND OPENINGS 7.1 Manholes Access is required inside fixed roof tanks for maintenance and inspection purposes. Such access can be provided through the roof or through the shell wall. Manholes through the roof have the advantage that they are always accessible, even when the tank is full. Access through the shell wall is more convenient for cleaning out (some access holes are D-shaped and flush with the bottom for cleaning out purposes). A manhole through a roof should be at least 500 mm diameter. Stiffening arrangements around the hole in the roof plate, and the type of cover, depend on the design of the roof. Access to the roof manhole must be provided by ladders, with suitable handrails and walkways on the roof. A manhole through the shell wall should be at least 600 mm diameter and is normally positioned just above the bottom of the tank. A typical detail is shown in section in Figure 13. Further details of this example, and details of clean-out openings, are given in BS2654 [1].
  • 29. Clearly, the cutting of an opening in the shell interferes with the structural action of the shell. The loss of section of shell plate is compensated by providing additional cross-section area equal to 75% of that lost. The area must be provided within a circular region around the hole, though the actual reinforcement should extend beyond that region. Reinforcement can be provided in one of three ways: (i) a reinforcing plate welded onto the shell plate (similar to the section in Figure 13) (ii) an insert of thicker plate locally (in which the manhole is cut) (iii) a thicker shell plate than that required for that course of the shell 7.2 Nozzles
  • 30. As well as manholes for access and cleaning out, nozzles are required through the shell roof and bottom for inlet, outlet, and drainage pipes, and for vents in the roof. They are normally made by welding a cylindrical section of plate into a circular hole in the structural plate. For small nozzles, no reinforcement is necessary, the extra material is considered sufficient. Larger holes must be reinforced in the same way as manholes. An example of a roof nozzle detail is shown in Figure 14. 8. CONCLUDING SUMMARY  Oil and oil products are most commonly stored in cylindrical steel tanks at atmospheric pressure or at low pressure. Water is also sometimes stored in cylindrical steel tanks.  The two design standards applied most widely to the design of welded cylindrical tanks are BS2654 and API 650.  Tanks are usually manufactured from plain carbon steel plate. It is readily weldable.  A tank is designed for the most severe combination of the various possible loadings.  For petroleum storage tanks, steel bottom plates are specified, laid and fully supported on a prepared foundation. Water tanks may also have a steel bottom or a reinforced concrete slab may be specified.
  • 31.  Vertical cylindrical tanks carry the hydrostatic pressure by simple hoop tension. The cylindrical shell has to carry both its own weight and the weight of the supported roof by axial stresses. Wind loading on the tank influences the axial stress.  For open tanks, primary wind girders are required to maintain the roundness of the tank when it is subject to wind load. Secondary wind girders are needed in tall tanks.  Roofs may be fixed or floating. A cover to the contents of a fixed roof tank may be provided to reduce evaporation or ingress of contaminants.  Manholes are provided for access and nozzles allow inlet, outlet and drainage, and venting of the space under the roof. 9. REFERENCES [1] BS 2654: 1984, Specification for manufacture of vertical steel welded storage tanks with butt-welded shells for the petroleum industry, British Standards Institution, London. [2] API 650, Welded Steel Tanks for Oil Storage, 8th Edition, November 1988, API. [3] BS EN 10025, 1990, Hot Rolled Products of Non-alloy Structural Steels and their Technical Delivery Conditions, British Standards Institution, London. [4] Young, W. C., Roark's Formulas for Stress and Strain, McGraw Hill, 1989. [5] BS 449: Part 2: 1969, Specification for the Use of Structural Steel in Building, British Standards Institution, London. Appendix A Differences between BS 2654 and API 650 The following are the principal differences between the British Standard, BS 2654 [1] and the American Petroleum Institute Standard, API650 [2]: (a) API 650 specifies different allowable stresses for service and water testing. BS 2654 specifies an allowable stress for water testing only, which will allow oils with any specific gravity up to 1 to be stored in the tank. (b) The allowable design stresses of BS 2654 are based on guaranteed minimum yield strength whereas the design stresses of API 650 are based on the guaranteed minimum ultimate tensile strength.
  • 32. (c) BS 2654 specifies more stringent requirements for the weldability of the shell plates. (d) The notch ductility requirements of BS 2654 are based on the results of a great number of wide plate tests. This system considers a steel acceptable if, for the required thickness, the test plate does not fail at test temperature before it has yielded at least 0,5%. This system gives the same safety factor for all thicknesses. In API 650 a fixed value and test temperature is given for the impact tests for all thicknesses. As the tendency to brittle fracture increases with increasing plate thickness it means that API 650 in fact allows a lower safety factor for large tanks than for smaller ones. (e) The steels specified by API 650 guarantee their notch ductility by chemical analysis but without guaranteed impact values. BS 2654 requires guaranteed impact values where necessary. (f) BS 2654 gives a clearer picture of how to determine the size and location of secondary wind girders. Previous | Next | Contents